document.xls Retaining Wall with up to 2 Wall Segments CRSI Example 1 9'-0" high amg 16 Jan 97 SOIL AND ADDITIONAL LATERAL LOAD DATA Soil Active Pressure (EFP) 31.164 psf/ft Total Retained Height of 9.000 ft Passive Soil Pressure (EFP 424.37 psf/ft Soil Depth over toe: 1 ft Soil Density: 115 pcf Toe soil to ignore: 1 ft Friction Coef w/passive: 0.45 Allowable soil pressure: 2000 psf Surcharge: 0 psf SR = soil reaction = portion of upward soil pressure Additional Lateral Load: 0 psf due wind to use for heel design = 0.75 Dist to start of load from 0 ft 25 percent reduction Dist to end of load from T 0 ft FOOTING DATA STEM SEGMENTS Footing Length: 4.666667 ft Wall Segments Footing Thickness: 12 inches Upper Wall Height: 9.000 ft Key Depth: 0 inches Lower Wall Height: 0.000 ft Key Width: 0 inches Total wall height: 9 ft Dist to face of key from 4.667 ft Upper Wall Thickness: 0.667 ft Toe length: 1.833333 ft Lower Wall Thickness: 0.667 ft Heel length: 2.167 ft Lower Wall Material: concrete f'c: 3000 psi Upper Wall Weight: 100 psf/ft Lower Wall Weight: 100 psf/ft FOOTING SHEARS AND MOMENTS Screen wall weight: 0 psf/ft At Toe: Distance to critical pla 1.833 ft 0 LATERAL PRESSURES Pressure at critical pla 1180 psf Active Pressure Vu toe: 2633 lbs Pa1 from soil: 1558.20 lbs/ft NVc: 9218 lbs OK! Pa2 from surch: 0.00 lbs/ft Pressure at face: 973 psf Pa3 from lat lo 0.00 lbs/ft Mu toe: 3829 ft-lbs Total Active: 1558.20 lbs/ft At Heel: Passive Pressure Distance to critical pla 2.167 ft Pp1: 424.37 psf Vu down: 3595 plf Pp2: 424.37 psf Pressure at face: 773 psf Total Passive: 636.56 lbs/ft Vu up: 1020 plf Vu heel: 2574 plf Total Friction: 1729 lbs NVc: 10894 lbs OK! Sliding Resist: 2366 lbs Mu heel local 3056 ft-lbs OTM: 5194 ft-lbs/ft Mu key: 0 ft-lbs STABILITY FACTORS OF SAFTEY Element Weight Arm from toe Rm Sliding: 1.520 Sliding OK! lbs ft ft-lbs OTM: 2.237 OTM OK! footing 700 2.333 1633 upper heel soil 2243 3.583 8036 ECCENTRICITY lower heel soil 0 3.583 0 e = 0.661 ft key 0 4.667 0 within kern upper wall 900 2.167 1950 Effective footing length 4.667 ft lower wall 0 2.167 0 screen wall 0 2.167 0 Lower Wall Segment Shear and Moment Weight total 3843 Rm total 11619 Vu stem: 2146 lbs Mu stem: 6437 ft lbs SOIL PRESSURES Upper Wall Segment Shear and Moment qmax = 1523 psf OK! Vu segment: 2146 lbs qmin = 123 psf Mu segment: 6437 ft lbs :: CRSI Example 1 9'-0" high STEEL REINFORCEMENT DESIGN n = 21.48 CMU Wall Reinf at base of Lower Stem Half Stresses: NO f'm = 1500 Fv allow = 38.7 psi Fb allowable 500 psi Bar Size = 7 design "d" = 9.44 inches ### Bar Area = 0.60 in**2 rho = 0.0079449153 Bar Spacing = 8 inches n = 21.48 Area/ft of wall 0.9 in**2/ft M design = 6437 ft-lbs k = 0.438 n*rho = 0.1706685499 j = 0.854 Stresses Wall Shear V design = 2146 lbs Masonry fb = 386 psi OK fv = 18.9 psi OK Steel fs = 10646 psi OK CMU Wall Reinf at base of Upper Stem Half Stresses: NO f'm = 1500 Fv allow = 38.7 psi Fb allowable 500 psi Bar Size = 5 design "d" = 5.25 inches ### Bar Area = 0.31 in**2 rho = 0.0036904762 Bar Spacing = 16 inches n = 21.48 Area/ft of wall 0.2325 in**2/ft M design = 6437 ft-lbs k = 0.327 n*rho = 0.0792768959 j = 0.891 Stresses Wall Shear V design = 2146 lbs Masonry fb = 1604 psi NG fv = 34.1 psi OK Steel fs = 71016 psi NG Concrete Toe Requirements: Ultimate Stress Use same steel from wall and bend into toe Bar Size = 4 design "d" = 8.25 inches ### Bar Area = 0.20 in**2 Mu in toe = 3829 ft-lbs Bar Spacing = 9 inches As in toe = 0.266666667 in**2/ft 2Mn = 9586 ft-lbs OK is greater than Mu Concrete Heel Reinforcement Requirements: Ultimate Stress Bar Size = 4 design "d" = 9.75 inches ### Bar Area = 0.20 in**2 Mu stem = 10943 ft-lbs Bar Spacing = 9 inches Mu key = 0 ft-lbs As in heel = 0.266666667 in**2/ft Mu toe = 3829 ft-lbs Mu heel local = 3056 ft-lbs Mu heel global 7114 ft-lbs Mu* heel = 7114 ft-lbs Mu heel design= 7114 ft-lbs 2Mn = 11386 ft-lbs OK is greater than Mu heel design

CRSI Ret Wall

Embed Size (px)

DESCRIPTION

EXCEL spreadsheet for CRSI type retaining walls. Spreadsheet calculates all based on the CRSI Design Handbook.

Citation preview

Page 1: CRSI Ret Wall

document.xls

Retaining Wall with up to 2 Wall SegmentsCRSI Example 1 9'-0" high amg 16 Jan 97

SOIL AND ADDITIONAL LATERAL LOAD DATASoil Active Pressure (EFP): 31.164 psf/ft Total Retained Height of Soil: 9.000 ftPassive Soil Pressure (EFP): 424.37 psf/ft Soil Depth over toe: 1 ftSoil Density: 115 pcf Toe soil to ignore: 1 ftFriction Coef w/passive: 0.45 Allowable soil pressure: 2000 psfSurcharge: 0 psf SR = soil reaction = portion of upward soil pressureAdditional Lateral Load: 0 psf due wind to use for heel design = 0.75Dist to start of load from TOF: 0 ft 25 percent reductionDist to end of load from TOF: 0 ft

FOOTING DATASTEM SEGMENTS Footing Length: 4.666667 ftWall Segments Footing Thickness: 12 inches Upper Wall Height: 9.000 ft Key Depth: 0 inches Lower Wall Height: 0.000 ft Key Width: 0 inchesTotal wall height: 9 ft Dist to face of key from toe: 4.667 ft Upper Wall Thickness: 0.667 ft Toe length: 1.833333 ft Lower Wall Thickness: 0.667 ft Heel length: 2.167 ft Lower Wall Material: concrete f'c: 3000 psiUpper Wall Weight: 100 psf/ftLower Wall Weight: 100 psf/ft FOOTING SHEARS AND MOMENTSScreen wall weight: 0 psf/ft At Toe:

Distance to critical plane: 1.833 ft 0LATERAL PRESSURES Pressure at critical plane: 1180 psfActive Pressure Vu toe: 2633 lbsPa1 from soil: 1558.20 lbs/ft NVc: 9218 lbs OK!Pa2 from surch: 0.00 lbs/ft Pressure at face: 973 psfPa3 from lat load:: 0.00 lbs/ft Mu toe: 3829 ft-lbsTotal Active: 1558.20 lbs/ft

At Heel:Passive Pressure Distance to critical plane: 2.167 ftPp1: 424.37 psf Vu down: 3594 plfPp2: 424.37 psf Pressure at face: 773 psfTotal Passive: 636.56 lbs/ft Vu up: 1020 plf

Vu heel: 2574 plfTotal Friction: 1729 lbs NVc: 10894 lbs OK!Sliding Resist: 2366 lbs Mu heel local: 3056 ft-lbs

OTM: 5194 ft-lbs/ft Mu key: 0 ft-lbs

STABILITY FACTORS OF SAFTEYElement Weight Arm from toe Rm Sliding: 1.520 Sliding OK!

lbs ft ft-lbs OTM: 2.237 OTM OK!footing 700 2.333 1633upper heel soil 2243 3.583 8036 ECCENTRICITYlower heel soil 0 3.583 0 e = 0.661 ftkey 0 4.667 0 within kern upper wall 900 2.167 1950 Effective footing length: 4.667 ftlower wall 0 2.167 0screen wall 0 2.167 0 Lower Wall Segment Shear and MomentWeight total 3843 Rm total 11619 Vu stem: 2146 lbs

Mu stem: 6437 ft lbs

SOIL PRESSURES Upper Wall Segment Shear and Momentqmax = 1523 psf OK! Vu segment: 2146 lbs

qmin = 123 psf Mu segment: 6437 ft lbs::CRSI Example 1 9'-0" highSTEEL REINFORCEMENT DESIGN n = 21.48

CMU Wall Reinf at base of Lower Stem Half Stresses: NO

f'm = 1500 Fv allow = 38.7 psiFb allowable 500 psi

Bar Size = 7 design "d" = 9.44 inches 0.875Bar Area = 0.60 in**2 rho = 0.0079449153

Bar Spacing = 8 inches n = 21.48Area/ft of wall = 0.9 in**2/ft M design = 6437 ft-lbs

k = 0.438 n*rho = 0.1706685499j = 0.854

Stresses Wall Shear V design = 2146 lbsMasonry fb = 386 psi OK fv = 18.9 psi OK

Steel fs = 10646 psi OK

CMU Wall Reinf at base of Upper Stem Half Stresses: NO

f'm = 1500 Fv allow = 38.7 psiFb allowable 500 psi

Bar Size = 5 design "d" = 5.25 inches 0.625Bar Area = 0.31 in**2 rho = 0.0036904762

Bar Spacing = 16 inches n = 21.48Area/ft of wall = 0.2325 in**2/ft M design = 6437 ft-lbs

k = 0.327 n*rho = 0.0792768959j = 0.891

Stresses Wall Shear V design = 2146 lbsMasonry fb = 1604 psi NG fv = 34.1 psi OK

Steel fs = 71016 psi NG

Concrete Toe Requirements: Ultimate StressUse same steel from wall and bend into toe

Bar Size = 4 design "d" = 8.25 inches 0.500Bar Area = 0.20 in**2 Mu in toe = 3829 ft-lbs

Bar Spacing = 9 inchesAs in toe = 0.266666667 in**2/ft

2Mn = 9586 ft-lbs OK is greater than Mu

Concrete Heel Reinforcement Requirements: Ultimate Stress

Bar Size = 4 design "d" = 9.75 inches 0.500Bar Area = 0.20 in**2 Mu stem = 10943 ft-lbs

Bar Spacing = 9 inches Mu key = 0 ft-lbsAs in heel = 0.266666667 in**2/ft Mu toe = 3829 ft-lbs

Mu heel local = 3056 ft-lbsMu heel global = 7114 ft-lbsMu* heel = 7114 ft-lbsMu heel design= 7114 ft-lbs

2Mn = 11386 ft-lbs OK is greater than Mu heel design