259

Cross-Reference & Online Spec Sheets - Datasheet Archive

  • Upload
    others

  • View
    32

  • Download
    0

Embed Size (px)

Citation preview

Page 3: Cross-Reference & Online Spec Sheets - Datasheet Archive

Cross-Reference & Online Spec Sheets We have expanded our Carol® Brand Electronics offering and now have more

competitive crosses than anyone. Many of these cables are in stock and ready for

immediate shipment from one of our stocking distributors. For questions on any

of the Carol Electronics cables, detailed spec sheets are now available online at

www.generalcable.com/Products/Electronics/Product Specification Sheets.

Carol® Brand has added the Sheer Wire™ line of cable for Lighting Control & Touch

Panel Systems to its already expansive electronics offering. For more information,

see page A2 or call 866-295-5896 today for your FREE Sheer Wire catalog.

What’s New?E X PA N D E D C O M P E T I T I V E O F F E R I N G S

S H E E R W I R E ™ P R O D U C T S

The Carol® Electronics Catalog has been revamped, with Plenum Cables now

being featured in the Communications & Control Multi-Conductor and Multi-Paired

sections. If you’re still not sure what you’re looking for, please contact our Customer

Service associates at 866.295.5896 today!

L O O K I N G F O R P L E N U M C A B L E S ?

General Cable has increased the information in its Alarm & Security Solutions

Guide, with the addition of Sheer Wire™ Cables for Lighting Control & Touch

Panel Systems, Bundled Composite Access Control Cables, Command® Series

Home Entertainment Cables and our line of Carol® Brand Helix/Hi-Temp® Data

Communications Cables. To view the updated guide, see pages 114-116 in

the catalog.

A L A R M & S E C U R I T Y S O L U T I O N S

Carol® Brand Electronics products are now offered with an interlock armored

option, which provides outstanding mechanical protection and is flexible for easy

installation, potentially saving time and money. For complete product information,

go to pages 179-180.

A R M O R E D E L E C T R O N I C S P R O D U C T S

A1

Page 4: Cross-Reference & Online Spec Sheets - Datasheet Archive

Carol® Brand Alarm & Security Solutions

A2

Applications:Lighting Controls Window Controls Audio Level Controls Video Controls Computer/Internet Controls

Cable Solution Description

1618SVA1 18/4 16/30 BC 20 AWG 10/30 + 16/1 PR 26/30 BC (UL) CL3R1822AXL0 22/1PR 7/30 + 18/2 7/26 (UL) CL3R FT-41822CCD8 Touch Panel Composite: 1 Control Element + 2 5e Elements1822CCT8 Touch Panel Composite: 1 Control Element + 2 5e Elements + 2 RG 61822CDC8 22C 5E: (1)I18/22CRT-89/04, (1)I181VQ6-09, I181VQ6-00, (2) Cat 5e1822CRT8 Comp 4C 2E: 22/1PR 7/30 BC 24 AWG 7/32 TC Drain + 1/2C 7/26 BC (UL) CL3R1822KYP1 Comp 4C 2E: 18/2C 16/30 BC + 22/1PR 7/30 BC Shielded182LUTDS 18/2 7/26 BC PVC NYLON (UL) TC for Lutron Dimmer & Switch184LUTDS 18/4 7/26 BC PVC Nylon O/A AM SHLD 20 AWG 7/36 TC Drain PVC222LUTDS 22/2 7/30 BC PVC O/A AM SHLD 24 AWG 7/32 TC Drain PVC164LTCH0 16/4 65/34 BC .012" PVC Lite Touch224SLTCH 22/4 7/30 BC .015 PVC, O/A AM SHLD, 24 7/32 TC Drain/A 0.35 PVC Lite TouchEF24C0021000 24/2 Conductor Shielded Low Cap Type CMP

Sheer Wire™ Lighting Control and Touch Panel SystemsCall today for your

FREE COMPLETESHEER WIRE™

CATALOG1.866.295.5896

Page 5: Cross-Reference & Online Spec Sheets - Datasheet Archive

Product Section LocatorSection PageS

1 Hook-Up Wire 1-7

2 communication & control cable, Multi-conductor 8-41

3 communication & control cable, Multi-Paired 42-66

4 computer cable 67-84

5 coaxial cable 85-112

6 Fire alarm/Life Safety cable 113-129

7 Sound, alarm & Security cable 130-145

8 audio/Video & Home entertainment cable 146-177

9 Specialty cable 178-185

10 technical information 186-247

Page 6: Cross-Reference & Online Spec Sheets - Datasheet Archive

Section PageS

1 Hook-Up Wire 1-7

UL 1007, UL 1569, CSA TR-64 ................................................................................................ 2UL 1015, CSA TEW .................................................................................................................. 3MIL-W-76B ............................................................................................................................... 4UL Types MTW, TFF, AWM & CSA TEW .................................................................................. 5Heavy Wall UL Types MTW, AWM & NEC Type THW .............................................................. 6Rubber/PVC/Polyethylene ........................................................................................................ 7

2 Communication & Control Cable, Multi-Conductor 8-41

Multi-Conductor, Unshielded .............................................................................................. 9-17Multi-Conductor, Unshielded (CSA) .................................................................................. 18-20Multi-Conductor, Rubber, Unshielded .................................................................................... 21Power-Limited Tray Cable, Unshielded .................................................................................. 22Multi-Conductor, Foil Shield .............................................................................................. 23-28Multi-Conductor, Foil Shield (CSA).................................................................................... 29-31Power-Limited Tray Cable, Foil Shield ................................................................................... 32Multi-Conductor, Spiral Shield ............................................................................................... 33Multi-Conductor, Braid Shield ........................................................................................... 34-37Multi-Conductor, Foil/Braid Shield ......................................................................................... 38Multi-Conductor, Foil & TC Braid Shield ................................................................................ 39Multi-Conductor, Rubber, Braid Shield .................................................................................. 40Multi-Conductor, Carolprene®, Braid Shield .......................................................................... 41

3 Communication & Control Cable, Multi-Paired 42-66

Multi-Paired, Unshielded ................................................................................................... 43-45Multi-Paired, Foil Shield .................................................................................................... 46-52Multi-Paired, Foil Shield (CSA) .......................................................................................... 53-54Multi-Paired, Foil Shield, Mid-Cap ......................................................................................... 55Multi-Paired, Foil Shield, Lo-Cap® ......................................................................................... 56Multi-Paired, Overall Foil & TC Braid Shield, Lo-Cap® .......................................................... 57Multi-Paired, Individually Shielded ......................................................................................... 58Multi-Paired, Individually Shielded (CSA) ............................................................................... 59Multi-Paired, Individually Shielded, Overall Shield ................................................................. 60Multi-Paired, Individually Foil Shielded ............................................................................. 61-64Power-Limited Tray Cable, Individually Shielded ................................................................... 65Power-Limited Tray Cable, Foil Shield or Foil/Braid Shield ................................................... 66

table of contents

Page 7: Cross-Reference & Online Spec Sheets - Datasheet Archive

table of contents

Section PageS

4 Computer Cable 67-84

Multi-Conductor, Foil Shield .............................................................................................. 68-69Multi-Conductor, Foil/Braid Shield .................................................................................... 70-71Multi-Conductor, Foil/Braid Shield, Lo-Cap® ......................................................................... 72Multi-Paired, Foil Shield ......................................................................................................... 73Multi-Paired, Foil Shield, Lo-Cap® ......................................................................................... 74Multi-Paired, Foil/Braid Shield ................................................................................................ 75Multi-Paired, Foil/Braid Shield, Lo-Cap® ........................................................................... 76-79Multi-Paired, Individually Foil Shielded ............................................................................. 80-82Multi-Paired, Individually Foil Shielded, Lo-Cap® .................................................................. 83Multi-Paired, Individually Foil/Braid Shielded, Lo-Cap®......................................................... 84

5 Coaxial Cable 85-112

Coaxial Solutions Guide .................................................................................................. 86-87

RG 6/U Type ...................................................................................................................... 88-93RG 8/U Type ...................................................................................................................... 94-95RG 11/U Type .................................................................................................................... 96-99RG 58/U Type ....................................................................................................................... 100RG 59/U Type ................................................................................................................ 101-108RG 62/U Type ....................................................................................................................... 109RG 174/U Type ..................................................................................................................... 110RG 213/U Type ..................................................................................................................... 111Twinaxial Cables ................................................................................................................... 112

6 Fire Alarm/Life Safety Cable 113-129

Alarm & Security Solutions Guide .............................................................................. 114-116

Multi-Conductor, Unshielded, Non-Plenum ......................................................................... 117Multi-Conductor, Unshielded, Non-Plenum (CSA) ............................................................... 118Multi-Conductor, Shielded, Non-Plenum ............................................................................. 119Multi-Conductor, Shielded, Non-Plenum (CSA) ................................................................... 120Multi-Conductor, Unshielded, Plenum .......................................................................... 121-122Multi-Conductor, Shielded, Plenum .............................................................................. 123-124Mid-Capacitance, Unshielded, Non-Plenum ....................................................................... 125Mid-Capacitance, Shielded, Non-Plenum ............................................................................ 126Mid-Capacitance, Unshielded, Plenum ................................................................................ 127Mid-Capacitance, Shielded, Plenum .................................................................................... 128Multi-Paired, Unshielded, Non-Plenum (CSA) ..................................................................... 129

Page 8: Cross-Reference & Online Spec Sheets - Datasheet Archive

table of contents

Section PageS

7 Sound, Alarm & Security Cable 130-145

Composite Access Control Cable ..................................................................................... 131

Composite Access Control Cable, Plenum .......................................................................... 132Composite Access Control Cable, Riser .............................................................................. 133Multi-Conductor, Unshielded, Riser ..................................................................................... 134Multi-Conductor, Shielded, Riser ......................................................................................... 135Multi-Conductor, Unshielded, Plenum ................................................................................. 136Multi-Conductor, Shielded, Plenum ..................................................................................... 137Telephone Station/Intercom & Speaker/Burglar Alarm ....................................................... 138Antenna Rotor ...................................................................................................................... 139Low-Voltage Sprinkler Wire .................................................................................................. 140Thermostat Wire Type LVT ................................................................................................... 141Thermostat Wire Type CL2 ................................................................................................... 142Thermostat Wire, Unjacketed ............................................................................................... 143Carol® Helix/Hi-Temp® Category 6 Cable ............................................................................ 144Carol® Helix/Hi-Temp® Category 5e Cable........................................................................... 145

8 Audio/Video & Home Entertainment Cable 146-177

Command® Series Home Entertainment Cables Guide ........................................... 147-148

Command® Series Cruise Ship Cables Guide .......................................................... 149-150

Command® Series Speaker Cable ................................................................................ 151-155Speaker Wire ........................................................................................................................ 156Superflex® Speaker Wire ...................................................................................................... 157Pro Audio Speaker Wire ....................................................................................................... 158Special Audio, Communication & Instrumentation ....................................................... 159-161Low Skew 4-Pair UTP .......................................................................................................... 162SmartWrap™ Bundled Cable ............................................................................................... 163Direct Burial, Audio & Communication .......................................................................... 164-165Digital Audio Snake Cable .................................................................................................... 166Analog Audio Snake Cable ........................................................................................... 167-168Guitar/Instrument Cable ....................................................................................................... 169Ultra Flexible, Low Impedance 2-Conductor Microphone Cable ........................................ 170Multi-Conductor, Flexfoil® Shield ......................................................................................... 171Multi-Conductor, Rubber, Braid Shield Microphone Cable .................................................. 172Multi-Conductor, Spiral Shield ............................................................................................. 173Multi-Conductor, Braid Shield .............................................................................................. 174Microphone Cable, Multi-Conductor, Carolprene®, Braid Shield ......................................... 175SMPTE-311 Hybrid Fiber Optic/Copper Camera Cable ...................................................... 176Electronic News Gathering/Field Production Camera Cable ............................................... 177

Page 9: Cross-Reference & Online Spec Sheets - Datasheet Archive

Section PageS

9 Specialty Cable 178-185

Armored Electronics Products Guide ........................................................................ 179-180

Wind Energy ........................................................................................................................ 181

Fluorobus Cable ................................................................................................................... 182Fire Wire ............................................................................................................................... 183Computer Cable ................................................................................................................... 184Composite Data and Control Cable ..................................................................................... 185

10 Technical Information 186-247

Insulation & Jacket Properties .............................................................................................. 187Decimal Conversion Factors ................................................................................................ 188Unit Conversion Factors ....................................................................................................... 189Temperature Conversion Chart ............................................................................................ 190Conduit Capacity Chart ........................................................................................................ 191Coax Connector Cross Reference ................................................................................ 192-199AWG Conductor Chart ......................................................................................................... 200Cable Design Equations—Braid Shield ................................................................................ 201Cable Design Equations—Coaxial Cable ............................................................................. 202Cable Design Equations—Balanced Pair ............................................................................. 203Engineering Prefixes ............................................................................................................. 204Glossary ......................................................................................................................... 205-215Abbreviations & Acronyms ............................................................................................ 216-218Product Finder—Hook-Up Wire ........................................................................................... 219Product Finder—Multi-Conductor Cable ...................................................................... 220-222Product Finder—Multi-Paired Cable ............................................................................. 223-225NEC/CEC Substitution Chart ........................................................................................ 226-227Agency Symbols ................................................................................................................... 228Agency Approval Index ........................................................................................................ 229Put-Ups and Color Codes .................................................................................................... 230Applications Index ......................................................................................................... 231-233Belden-to-General Cable Carol® Brand Cross Reference Index .................................. 234-239Part Number Index ........................................................................................................ 240-246Notes .................................................................................................................................... 247

table of contents

Page 10: Cross-Reference & Online Spec Sheets - Datasheet Archive

Alben Roland –Wire Wizard.SM When it comes to solving your problems, he makes magic happen.

Alben’s highest and most challenging form of wire wizardry is new product development, followed closely by solving tough, often one-of-a-kind technical problems. His powers are also evident in quality control and in laboratory testing. We call on Alben to perform his wizardry all the time. And so do our customers. Alben, Manager, Product Engineering, Carol® Brand Electronic Products, and the entire team of General Cable Wire Wizards are ready to perform magic. “Whether it’s providing a prototype, solving an applications problem, or answering a technical question, we try to make magic happen,” explains Alben. Magic or not, our Wizards always seem to find the answer and serve the customer. And there’s no smoke or mirrors about that.

REEL People ... Adding REAL Value

If you’d like to put the powers of Alben and General Cable Carol Brand products to work for you, talk to a General Cable rep today. To connect, just call 1.888.295.5896 or e-mail us at [email protected].

www.generalcable.com

There is a reasonwe call him –

SM

WireWizard.

Page 11: Cross-Reference & Online Spec Sheets - Datasheet Archive

Our Green Initiative symbol recognizes our role and responsibility in promoting

sustainability. The symbol also reflects our commitment to achieving industry-

leading standards and responding proactively to environmental global issues.

Visit www.generalcable.comSelect “company”, then select “environmental”

Look for our products with the RoHS symbol for your green building initiatives.

General Cable is a leader in the development,

design, manufacture, marketing and distribution

of copper, aluminum and fiber optic wire and

cable for the energy, industrial, specialty and

communications markets.

Our products inspire progress worldwide …

customers use our value-added products

to create global infrastructure that improves the

standard of living for people everywhere.

Each day we’re building business momentum —

developing ideas into innovative solutions and

industry-leading products, expanding geographic

access and furthering our investment in highly

capable associates, Lean Manufacturing,

material science and technology resources.

General Cable is influencing the world … with more than two-thirds of our

sales generated outside North America and more than 11,000 associates in

45 manufacturing facilities throughout 22 countries. As one of the largest wire

and cable manufacturers, we are the One Company Connecting the World.

Energy Cables Our cables carry energy across the world — through the air, underground

and under the sea. Increasing demand for energy is accelerating investment

in exploration, extraction, power generation, transmission and distribution —

whether based on coal, natural gas, oil, nuclear, wind, solar or water.

Industrial & Specialty Cables Our cables channel the power and signals that make equipment hum and

engines run. From oil rigs and broadcast studios to cars and trains, and in

commercial buildings, public venues, factory floors and special applications

such as military, nuclear, marine and mining — we serve an extensive range

of markets.

Communications Cables Our cables keep information flowing — facilitating a non-stop stream of

words and images around the world. We meet the high-speed bandwidth

needs of global communications networks, from fiber optic submarine

communications cables, copper and fiber aerial and underground cables,

to copper and fiber optic enterprise cables and system solutions.

World Headquarters - General Cable 4 Tesseneer Drive • Highland Heights, KY • 41076-9753 U.S.A.

Building Bridges in the Sky

Making Contact with the World

Directing Traffic without Gridlock

Page 12: Cross-Reference & Online Spec Sheets - Datasheet Archive

1

Electronics

Index Page

UL 1007, UL 1569, CSA TR-64 2

UL 1015, CSA TEW 3

MIL-W-76B 4

UL Types MTW, TFF, AWM & CSA TEW 5

Heavy Wall UL Types MTW, AWM & NEC Type THW 6

Rubber/PVC/Polyethylene 7

Most applications of hook-up and lead wire for board-to-board or point-to-point wiring rely on PVC-insulated designs.

General Cable’s Carol® Brand products offer both electrical and electronic designers a vast array of quality PVC hook-up wire to meet the specific technical demands of today, with ‘‘off-the-shelf” distributor inventoried products.

Hook-up wire is also available in special colors and/or stripe combinations with a minimum of lead time. In addition, General Cable offers a variety of put-ups to meet individual customer requirements.

Hook-Up Wire 1

Page 13: Cross-Reference & Online Spec Sheets - Datasheet Archive

2

Electronics Hook-Up Wire

UL 1007, UL 1569, cSa tR-64

Product Construction: Conductor: •24thru16AWG •Fullyannealedtinnedcopperper

ASTM B-33 •Solidorstranded

Insulation: •Premium-grade,coIor-codedPVC •Temperaturerange:-20˚Cto+105˚C •Colorcode:Seechartbelow

Applications: •Internalwiringofelectricalandelectronic

equipment •Internalwiringofpanelsandmeters •Point-to-pointwiring •Suggestedvoltagerating:300volts

Compliances: •ULStyle1007–80˚C,300V •ULStyle1569–105˚C,300V •CSATR-64–90°C,300V •RoHSCompliantDirective2002/95/EC •DesignedtomeetULVW-1VerticalWire

Flame Test

Packaging: •PleasecontactCustomerServicefor

packaging and color options

cataLog nUMBeR

aWg SiZe

conD. StRanD

noM. inSULation tHicKneSS noMinaL o.D.

incHeS mm incHeS mm

SOLID CONDUCTORS

C2003A 24 Solid 0.016 0.41 0.052 1.32

C2004A 22 Solid 0.016 0.41 0.057 1.45

C2028A 20 Solid 0.016 0.41 0.064 1.63

C2052A 18 Solid 0.016 0.41 0.072 1.83

C2053A 16 Solid 0.016 0.41 0.083 2.11

STRANDED CONDUCTORS

C2015A 24 7/32 0.016 0.41 0.056 1.42

C2016A 22 7/30 0.016 0.41 0.062 1.57

C2040A 20 10/30 0.016 0.41 0.070 1.78

C2064A 18 16/30 0.016 0.41 0.080 2.03

C2065A 16 26/30 0.016 0.41 0.092 2.34

Color Code ChartoRDeRing

SUFFiX coLoRSoRDeRing

SUFFiX coLoRS

01 Black 06 Green

02 White 07 Blue

03 Red 08 Brown

04 Orange 10 Gray

05 Yellow 19 VioletStriped combinations available upon request; consult Customer Service.

Page 14: Cross-Reference & Online Spec Sheets - Datasheet Archive

3

Hook-Up Wire Electronics

UL 1015, cSa teW

Product Construction: Conductor: •24thru10AWG •Fullyannealedtinnedcopperper

ASTM B-33 •Solidorstranded

Insulation: •Premium-grade,coIor-codedPVC •Temperaturerange:-20˚Cto+105˚C •Colorcode:Seechartbelow

Applications: •Internalwiringofelectricalandelectronic

equipment •Internalwiringofpanelsandmeters •Point-to-pointwiring •Suggestedvoltagerating:600volts

Compliances: •ULStyle1015–105°C,600V •CSATypeTEW •RoHSCompliantDirective2002/95/EC •DesignedtomeetULVW-1VerticalWire

Flame Test

Packaging: •PleasecontactCustomerServicefor

packaging and color options

cataLognUMBeR

aWgSiZe

conD.StRanD

noM. inSULationtHicKneSS noMinaL o.D.

incHeS mm incHeS mm

SOLID CONDUCTORS

C2117A 22 Solid 0.032 0.81 0.089 2.26

C2118A 20 Solid 0.032 0.81 0.096 2.44

C2119A 18 Solid 0.032 0.81 0.104 2.64

STRANDED CONDUCTORS

C2100A 24 7/32 0.032 0.81 0.088 2.24

C2101A 22 7/30 0.032 0.81 0.094 2.39

C2102A 20 10/30 0.032 0.81 0.102 2.59

C2103A 18 16/30 0.032 0.81 0.112 2.84

C2104A 16 26/30 0.032 0.81 0.124 3.15

C2105A 14 41/30 0.032 0.81 0.141 3.58

C2106A 12 65/30 0.032 0.81 0.160 4.06

C2107A 10 105/30 0.033 0.84 0.184 4.67

Color Code ChartoRDeRing

SUFFiX coLoRSoRDeRing

SUFFiX coLoRS

01 Black 06 Green

02 White 07 Blue

03 Red 08 Brown

04 Orange 10 Gray

05 Yellow 19 VioletStriped combinations available upon request; consult Customer Service.

Page 15: Cross-Reference & Online Spec Sheets - Datasheet Archive

4

Electronics Hook-Up Wire

MiL-W-76B Type MW

Product Construction: Conductor: •24thru12AWG •Fullyannealedstrandedtinnedcopper

per ASTM B-33

Insulation: •Premium-grade,coIor-codedPVC •TypeMW:Mediumwall •Temperaturerange:-12°Cto+90°C •Colorcode:Seechartbelow

Applications: •Internalwiringofelectricalandelectronic

equipment •Internalwiringofpanelsandmeters •Point-to-pointwiring •Suggestedvoltagerating:1000volts

(MIL-W-76B) •NonQPL

Compliances: •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

cataLognUMBeR

tYPeDeSignation

aWgSiZe

conD.StRanD

noM. inSULationtHicKneSS noMinaL o.D.

incHeS mm incHeS mm

MIL-W-76B TYPE MW (MEDIUM WALL)

C7600A MW-C24(7)U 24 7/32 0.016 0.41 0.056 1.42

C7602A MW-C22(7)U 22 7/30 0.016 0.41 0.062 1.57

C7604A MW-C20(10)U 20 10/30 0.016 0.41 0.070 1.78

C7606A MW-C18(16)U 18 16/30 0.016 0.41 0.080 2.03

C7608A* MW-C16(26)U 16 26/30 0.016 0.41 0.092 2.34

C7610A* MW-C14(41)U 14 41/30 0.016 0.41 0.109 2.77

C7611A* MW-C12(65)U 12 65/30 0.016 0.41 0.128 3.25

*-25˚Cto+105˚C

Color Code ChartoRDeRing

SUFFiX coLoRSoRDeRing

SUFFiX coLoRS

01 Black 06 Green

02 White 07 Blue

03 Red 08 Brown

04 Orange 10 Gray

05 Yellow 19 VioletStriped combinations available upon request; consult Customer Service.

Page 16: Cross-Reference & Online Spec Sheets - Datasheet Archive

5

Hook-Up Wire Electronics

UL types MtW, tFF, aWM & cSa teW 90ºC 600 Volt MTW, TFF 105ºC 600 Volt AWM/TEW

Product Construction: Conductor: •18through8AWGfullyannealed

stranded bare copper per ASTM B-8

Insulation: •Premium-grade,coIor-codedPVC •Temperaturerange:

MTW:-40ºCto+90ºC TEW/AWM:-20ºCto+105ºC

•Colorcode:Seechartbelow

Jacket Marking: •18and16AWG:

CAROL (SIZE) 600V E# MTW (UL) OR TFF OR AWM VW-1 --- CSA TEW 105ºC FT-1

•14through8AWG: CAROL (SIZE) 600V E# MTW (UL) OR AWM VW-1 --- CSA TEW 105ºC FT-1

Applications: •Motorandtransformerlead •Externalwiringofmachinery •Internalwiringofelectricalandelectronic

equipment •Internalwiringofpanelsandmeters •Point-to-pointwiring

Features: •Outstandingoil,flameandmoisture

resistance •Extraflexible

Compliances: •ULandNMTBATypeMTW/AWM •CSATEW •RoHSCompliantDirective2002/95/EC •PassesVW-1VerticalFlameTest •AWMStyle1015–18-8AWG •AWMStyle1335–18-10AWG •AWMStyle1336–8AWG

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Color Code ChartoRDeRing

SUFFiX coLoRSoRDeRing

SUFFiX coLoRS

01 Black 04 Orange

02 White 08 Brown

03 Red 19 Purple

07 Blue 10 Gray

06 Green 13 Pink

cataLognUMBeR

aWgSiZe

conD.StRanD

noM. inSULationtHicKneSS noMinaL o.D.

StocKcoLoRS

aPPRoX.net WeigHt

LBS/M(S)incHeS mm incHeS mm

UL TYPE MTW, AWM, TFF, CSA TYPE TEW–600 VOLT

76502 18 16/30 0.032 0.81 0.110 2.79 1-12 10

76512 16 26/30 0.032 0.81 0.123 3.12 1-12 14

76812 14 19/.0159 0.032 0.81 0.136 3.40 1-12 20

76822 12 19/.0185 0.032 0.81 0.155 3.91 1-7 28

76832 10 19/.0234 0.032 0.81 0.179 4.55 1-5 42

76843 8 19/.0295 0.047 1.19 0.242 6.15 1-5 72(S) Actual shipping weight may vary.

Page 17: Cross-Reference & Online Spec Sheets - Datasheet Archive

6

Electronics Hook-Up Wire

Heavy Wall UL types MtW, aWM & nec type tHW

90ºC 600 Volts

Product Construction: Conductor: •6and4AWGfullyannealedstranded

bare copper per ASTM B-8

Insulation: •Premium-grade,coIor-codedPVC,black •Temperaturerange:-40ºCto+90ºC

Jacket Marking: •CAROL6AWG600VE#MTWORTHW

(UL) OR AWM

Applications: •Motorandtransformerlead •Externalwiringofmachinery

Features: •Outstandingoil,flameandmoisture

resistance •Extraflexible

Compliances: •ULTypeAWM •ULandNMTBATypeMTW •NECTypeTHW •RoHSCompliantDirective2002/95/EC •PassesULVW-1VerticalFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

cataLognUMBeR

aWgSiZe

conD.StRanD

noM. inSULationtHicKneSS noMinaL o.D. aPPRoX.

net WeigHtLBS/m(S)incHeS mm incHeS mm

AWM, MTW, THW – 600 VOLT – UL

76954 6 19/.0372 0.064 1.63 0.315 8.00 110

76994 4 19/.0469 0.065 1.65 0.365 9.27 150(S)Actual shipping weight may vary.

Page 18: Cross-Reference & Online Spec Sheets - Datasheet Archive

7

Hook-Up Wire Electronics

Rubber/PVc/Polyethylene

Product Construction: Conductor: •20,18and14AWG •Fullyannealedstrandedtinnedcopper

per ASTM B-33

Insulation: •Premium-grade,coIor-codedrubber,

PVC or polyethylene •Temperaturerange:

-20˚Cto+60˚Crubber -25˚Cto+60˚CPVC -20˚Cto+80˚Cpolyethylene

•Colorcode:Seechartbelow

Applications: •Testequipment •Oscillators

Compliances: •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

cataLognUMBeR

no. oFconD.

aWgSiZe

conD.StRanD

noM. inSULationtHicKneSS

BReaKDoWnVoLtage(ac, rms)

WoRKingVoLtage*

noMinaL o.D.

incHeS mm incHeS mm

RUBBER TEST LEAD

C1326 1 20 41/36 0.040 1.02 6,000V 1,500V 0.125 3.18

C1319 1 20 41/36 0.047 1.19 12,000V 3,000V 0.140 3.56

C1321 1 18 65/36 0.045 1.14 20,000V 5,000V 0.145 3.68

C1318 1 18 65/36 0.088 2.24 29,000V 10,000V 0.230 5.84

PVC TEST LEAD

C1320A 1 18 65/36 0.047 1.19 20,000V 5,000V 0.140 3.56

POLYETHYLENE TEST LEAD

C7108A 1 14 105/34 0.032 0.81 4,000V 600V 0.140 3.56

*For intermittent duty only.

Color Code ChartoRDeRing

SUFFiX coLoRS

01 Black

03 Red

06 Green

Page 19: Cross-Reference & Online Spec Sheets - Datasheet Archive

8

Electronics

Index Page

Multi-Conductor, Unshielded 9-17

Multi-Conductor, Unshielded (CSA) 18-20

Multi-Conductor, Rubber, Unshielded 21

Power-Limited Tray Cable, Unshielded 22

Multi-Conductor, Foil Shield 23-28

Multi-Conductor, Foil Shield (CSA) 29-31

Power-Limited Tray Cable, Foil Shield 32

Multi-Conductor, Spiral Shield 33

Multi-Conductor, Braid Shield 34-37

Multi-Conductor, Foil/Braid Shield 38

Multi-Conductor, Foil & TC Braid Shield 39

Multi-Conductor, Rubber, Braid Shield 40

Multi-Conductor, Carolprene,® Braid Shield 41

The multi-conductor array of communication and control cable facilitates cable pull-ins and single-site installations.

This cable is typically used for industrial equipment control, electric valve actuation and remote signaling, as well as communications and broadcast applications. These designs are available in a wide variety of insulation and jacketing materials, as well as shield designs to alleviate unwanted circuit noise.

General Cable’s Carol® Brand products are manufactured to meet the latest UL, CSA and NEC requirements and approvals.

A Design To Meet Every Application

PVC/PVC designs employ polyvinyl chloride insulations and jackets capable of meeting everyday, general purpose applications.

PE or PP/PVC designs employ high quality polyethylene or polypropylene insulations to assure faithful reproduction of transmitted signals across interconnection circuits.

Foamed PP/PVC designs use high speed, foamed polypropylene insulations for long-distance critical circuits, which would not perform if higher loss insulations were employed.

FEP/FEP designs employ fluoropolymer 200°C-rated materials. They are recommended for use in applications where high temperature, plenum rating, electrical and mechanical safety and chemical resistance are essential.

Rubber/Rubber is typically employed in installations characterized as severely hostile environments, where these designs provide unsurpassed service life.

Rubber/Carolprene® offers the ultimate performance for applications that demand the greatest protection from the environment, including physical abuse. The specially formulated Carolprene® jacket has been proven time and again to withstand all types of abuse, both mechanical and chemical.

Communication & Control Cable, Multi-Conductor 2

Page 20: Cross-Reference & Online Spec Sheets - Datasheet Archive

9

Communication & Control Cable, Multi-Conductor Electronics

Product Construction: Conductor: •Fullyannealedtinnedcopperper

ASTM B-33 (C4008A, C4311A) •Fullyannealedsolidbarecopperper

ASTM B-3 (C2754A)

Insulation: •Premium-grade,coIor-codedS-RPVC

per UL 1061

Jacket: •PVC,gray •Temperaturerange:-20°Cto+80°C

Applications: •Publicaddresssystems •Intercoms •Remotecontrolcircuits •Suggestedvoltagerating:300volts

Compliances: •NECArticle800TypeCM(UL:75°C) •ULStyle2464(UL:80°C,300V) •CSACMG(CSA:60°C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Multi-Conductor, Unshielded UL 2464, NEC Type CM (UL) c(UL), CSA CMG

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS

NOM. JACKETTHICKNESS NOMINAL O.D.

COLORCODE

NOM.C-C

CAP.*pF/ftINCHES mm INCHES mm INCHES mm

C4008A 2 22 Solid 0.010 0.25 0.032 0.81 0.156 3.94 Black/Red 24.5

C4311A 2 20 Solid 0.010 0.25 0.032 0.81 0.166 4.22 Black/Red 28.0

C2754A 2 19 Solid 0.010 0.25 0.032 0.81 0.176 4.47 Brown/Tan 29.5

*Capacitance between conductors

Page 21: Cross-Reference & Online Spec Sheets - Datasheet Archive

10

Electronics Communication & Control Cable, Multi-Conductor

Multi-Conductor, Unshielded UL 2464, NEC Type CM (UL) c(UL), CSA CMG

Product Construction: Conductor: •22thru18fullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedPVC(18

AWG),S-RPVC(22AWG) •Colorcode:Seechartbelow

Jacket: •PVC,gray •Temperaturerange:-20°Cto+80°C

Applications: •TVantennarotorcontrol •Satelliteactuatorcontrol •Publicaddresssystems •Suggestedvoltagerating:300volts

Features: •Tinnedcopperconductorsprovide

excellent corrosion resistance •Assistswithsolderingapplications

Compliances: •NECArticle800TypeCM(UL:75°C) •ULStyle2464(UL:80°C,300V) •CSACMG(CSA:60°C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS

NOM. JACKETTHICKNESS NOMINAL O.D.

NOM.C-C

CAP.*pF/ftINCHES mm INCHES mm INCHES mm

C4081A 6 4-222-18

7/3016/30

0.0100.016

0.250.41 0.032 0.81 0.244 6.20 24.5

31.0

C4082A 7 5-222-18

7/3016/30

0.0100.016

0.250.41 0.032 0.81 0.253 6.43 24.5

31.0

C4083A 8 6-222-18

7/3016/30

0.0100.016

0.250.41 0.032 0.81 0.263 6.69 24.5

31.0

C4084A 9 7-222-18

7/3016/30

0.0100.016

0.250.41 0.032 0.81 0.273 6.94 24.5

31.0*Capacitance between conductors

Color Code ChartNO. OFCOND. COLOR

1 18 ga. Black

2 White

1 22 ga. Red

2 Green

3 Brown

4 Blue

5 Orange

6 Yellow

7 Violet

Page 22: Cross-Reference & Online Spec Sheets - Datasheet Archive

11

Communication & Control Cable, Multi-Conductor Electronics

Multi-Conductor, Unshielded UL 2464, UL 2576, NEC Type CM (UL) c(UL), CSA CMG

Product Construction: Conductor: •24AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedS-RPVC

per UL 1061 •Colorcode:Seechartsbelow

Jacket: •PVC,gray •Temperaturerange:-20°Cto+80°C

Applications: •Publicaddresssystems •Intercoms •Internaltelephones •Remotecontrolcircuits •SuitableforEIARS-232applications •Suggestedvoltagerating:300volts

Features: •Easytoterminate •Excellentelectricalproperties •Tinnedconductorsprovideexcellent

corrosion resistance •Assistssolderingapplications

Compliances: •NECArticle800TypeCM(UL:75°C) •ULStyle2464(UL:80°C,300V) •ULStyle2576(UL:80˚C,150V) •CSACMG(CSA:60°C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS

NOM. JACKETTHICKNESS NOMINAL O.D.

COLORCODE

NOM.C-C

CAP.*pF/ftINCHES mm INCHES mm INCHES mm

C2461A 2 24 7/32 0.010 0.25 0.032 0.81 0.152 3.86 Black/Red 23.0

C2462A 3 24 7/32 0.010 0.25 0.032 0.81 0.163 4.14Black/Red/Green

23.0

C2463A 4 24 7/32 0.010 0.25 0.032 0.81 0.174 4.42 1 23.0

C2464A 5 24 7/32 0.010 0.25 0.032 0.81 0.183 4.75 1 23.0

C2466A 6 24 7/32 0.010 0.25 0.032 0.81 0.200 5.08 1 23.0

C2488A 7 24 7/32 0.010 0.25 0.032 0.81 0.200 5.08 1 23.0

C2465A 8 24 7/32 0.010 0.25 0.032 0.81 0.214 5.44 1 23.0

C2470A 9 24 7/32 0.010 0.25 0.032 0.81 0.227 5.77 1 23.0

C2471A 10 24 7/32 0.010 0.25 0.032 0.81 0.244 6.20 1 23.0

C2467A 12 24 7/32 0.010 0.25 0.032 0.81 0.251 6.38 1 23.0

C2473A 15 24 7/32 0.010 0.25 0.032 0.81 0.275 6.99 2 23.0

*Capacitance between conductors

Color Code Chart 1 - For cables up to and including 12 conductors

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 7 Orange2 White 8 Yellow3 Red 9 Violet4 Green 10 Gray5 Brown 11 Pink6 Blue 12 Tan

Color Code Chart 2 Per ICEA - For cables with 15 conductors

NO. OFCOND. COLOR

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 6 Blue 11 Blue/Black2 White 7 White/Black 12 Black/White3 Red 8 Red/Black 13 Red/White4 Green 9 Green/Black 14 Green/White5 Orange 10 Orange/Black 15 Blue/White

Page 23: Cross-Reference & Online Spec Sheets - Datasheet Archive

12

Electronics Communication & Control Cable, Multi-Conductor

Multi-Conductor, Unshielded UL 2464, UL 2576, NEC Type CM (UL) c(UL), CSA CMG

Product Construction: Conductor: •22AWGfullyannealed,strandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedS-RPVC

per UL 1061 •Colorcode:Seechartsbelow

Jacket: •PVC,gray •Temperaturerange:-20°Cto+80˚C

Applications: •Publicaddresssystems •Intercoms •Internaltelephones •Remotecontrolcircuits •SuitableforEIARS-232applications •Suggestedvoltagerating:300volts

Features: •Easytoterminate •Excellentelectricalproperties •Tinnedconductorsprovideexcellent

corrosion resistance •Assistssolderingapplications

Compliances: •NECArticle800TypeCM(UL:75°C) •ULStyle2464(UL:80°C,300V) •ULStyle2576(UL:80˚C,150V) •CSACMG(CSA60°C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS

NOM. JACKETTHICKNESS NOMINAL O.D.

COLORCODE

NOM.C-C

CAP.*pF/ftINCHES mm INCHES mm INCHES mm

C6348A† 2 22 7/30 0.010 0.25 0.015 0.38 0.130 3.30 Black/Red 24.5

C4062A 3 22 7/30 0.010 0.25 0.032 0.81 0.176 4.47Black/Red/Green

24.5

C4063A 4 22 7/30 0.010 0.25 0.032 0.81 0.189 4.80 1 24.5

C4064A 5 22 7/30 0.010 0.25 0.032 0.81 0.203 5.16 1 24.5

C4066A 6 22 7/30 0.010 0.25 0.032 0.81 0.218 5.54 1 24.5

C4088A 7 22 7/30 0.010 0.25 0.032 0.81 0.205 5.54 1 24.5

C4065A 8 22 7/30 0.010 0.25 0.032 0.81 0.230 5.94 1 24.5

C4070A 9 22 7/30 0.010 0.25 0.032 0.81 0.249 6.32 1 24.5

C4071A 10 22 7/30 0.010 0.25 0.032 0.81 0.268 6.81 1 24.5

C4067A 12 22 7/30 0.010 0.25 0.032 0.81 0.276 7.01 1 24.5

C4073A 15 22 7/30 0.010 0.25 0.032 0.81 0.303 7.70 2 24.5

C4075A 20 22 7/30 0.010 0.25 0.032 0.81 0.334 8.48 2 24.5

C4076A 25 22 7/30 0.010 0.25 0.032 0.81 0.368 9.35 2 24.5

C4077A 30 22 7/30 0.010 0.25 0.032 0.81 0.389 9.88 2 24.5

C4078A 40 22 7/30 0.010 0.25 0.032 0.81 0.434 11.02 2 24.5

C4079A 50 22 7/30 0.010 0.25 0.032 0.81 0.489 12.42 2 24.5*Capacitance between conductors †CM-CSA CMG Only

Color Code Chart 1 - For cables up to and including 12 conductors

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 7 Orange2 White 8 Yellow3 Red 9 Violet4 Green 10 Gray5 Brown 11 Pink6 Blue 12 Tan

Color Code Chart 2 Per ICEA - For cables of 15 thru 50 conductors

NO. OFCOND. COLOR

NO. OFCOND. COLOR

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 14 Green/White 27 Blue/Black/White 39 White/Black/Green2 White 15 Blue/White 28 Black/Red/Green 40 Red/White/Green3 Red 16 Black/Red 29 White/Red/Green 41 Green/White/Blue4 Green 17 White/Red 30 Red/Black/Green 42 Orange/Red/Green5 Orange 18 Orange/Red 31 Green/Black/Orange 43 Blue/Red/Green6 Blue 19 Blue/Red 32 Orange/Black/Green 44 Black/White/Blue7 White/Black 20 Red/Green 33 Blue/White/Orange 45 White/Black/Blue8 Red/Black 21 Orange/Green 34 Black/White/Orange 46 Red/White/Blue9 Green/Black 22 Black/White/Red 35 White/Red/Orange 47 Green/Orange/Red10 Orange/Black 23 White/Black/Red 36 Orange/White/Blue 48 Orange/Red/Blue11 Blue/Black 24 Red/Black/White 37 White/Red/Blue 49 Blue/Red/Orange12 Black/White 25 Green/Black/White 38 Black/White/Green 50 Black/Orange/Red13 Red/White 26 Orange/Black/White

Page 24: Cross-Reference & Online Spec Sheets - Datasheet Archive

13

Communication & Control Cable, Multi-Conductor Electronics

Multi-Conductor, Unshielded UL 2464, UL 2576, NEC Type CM (UL) c(UL), CSA CMG

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS

NOM. JACKETTHICKNESS NOMINAL O.D.

COLORCODE

NOM.C-C

CAP.*pF/ftINCHES mm INCHES mm INCHES mm

C6351A† 2 20 7/28 0.016 0.41 0.025 0.64 0.192 4.88 Black/Red 28.0

C6352A 3 20 7/28 0.016 0.41 0.032 0.81 0.216 5.50 1 28.0

C6353A 4 20 7/28 0.016 0.41 0.032 0.81 0.235 5.97 1 28.0

C6355A 5 20 7/28 0.016 0.41 0.032 0.81 0.254 6.46 1 28.0

C6356A 7 20 7/28 0.016 0.41 0.032 0.81 0.275 6.99 1 28.0

C6357A 9 20 7/28 0.016 0.41 0.032 0.81 0.317 8.05 1 28.0

C6360A 12 20 7/28 0.016 0.41 0.032 0.81 0.354 9.00 2 28.0

C6358A 15 20 7/28 0.016 0.41 0.032 0.81 0.392 9.96 2 28.0

C2830A† 2 18 16/30 0.016 0.41 0.015 0.64 0.190 5.33 Black/Red 30.5

C2831A 3 18 16/30 0.016 0.41 0.032 0.81 0.236 5.99 1 30.5

C2404A 4 18 16/30 0.016 0.41 0.032 0.81 0.258 6.55 1 30.5

C2420A 5 18 16/30 0.016 0.41 0.032 0.81 0.280 7.11 1 30.5

C2421A 7 18 16/30 0.016 0.41 0.032 0.81 0.309 7.85 1 30.5

C2422A 9 18 16/30 0.016 0.41 0.032 0.81 0.358 9.09 1 30.5

C2412A 12 18 16/30 0.016 0.41 0.032 0.81 0.401 10.19 2 30.5

C2423A 15 18 16/30 0.016 0.41 0.032 0.81 0.445 11.30 2 30.5

C2424A 19 18 16/30 0.016 0.41 0.032 0.81 0.469 11.91 2 30.5

C2433A 25 18 16/30 0.016 0.41 0.032 0.81 0.550 13.94 2 30.5*Capacitance between conductors †CM (UL) c(UL), CSA CMG Only

Color Code Chart 1 - For cables up to and including 9 conductors

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 6 Blue2 White 7 Orange3 Red 8 Yellow4 Green 9 Violet5 Brown

Color Code Chart 2 Per ICEA - For cables of 12 thru 25 conductors

NO. OFCOND. COLOR

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 10 Orange/Black 19 Blue/Red2 White 11 Blue/Black 20 Red/Green3 Red 12 Black/White 21 Orange/Green4 Green 13 Red/White 22 Black/White/Red5 Orange 14 Green/White 23 White/Black/Red6 Blue 15 Blue/White 24 Red/Black/White7 White/Black 16 Black/Red 25 Green/Black/White8 Red/Black 17 White/Red9 Green/Black 18 Orange/Red

Product Construction: Conductor: •20or18AWGfullyannealedstranded,

tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedPVCper

UL 1007 •Colorcode:Seechartsbelow

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+80°C

Applications: •Publicaddresssystems •Intercoms •Internaltelephones •Remotecontrolcircuits •SuitableforEIARS-232applications •Suggestedvoltagerating:300volts

Compliances: •NECArticle800TypeCM(UL:75°C) •ULStyle2464(UL:80°C,300V) •ULStyle2576(UL:80˚C,150V) •CSACMG(CSA:60°C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Page 25: Cross-Reference & Online Spec Sheets - Datasheet Archive

14

Electronics Communication & Control Cable, Multi-Conductor

Multi-Conductor, Unshielded UL 2464, UL 2587, NEC Type CL3 and CM (UL) c(UL), CSA CMG

Color Code Chart Per ICEA

NO. OFCOND. COLOR

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 10 Orange/Black 19 Blue/Red2 White 11 Blue/Black 20 Red/Green3 Red 12 Black/White 21 Orange/Green4 Green 13 Red/White 22 Black/White/Red5 Orange 14 Green/White 23 White/Black/Red6 Blue 15 Blue/White 24 Red/Black/White7 White/Black 16 Black/Red 25 Green/Black/White8 Red/Black 17 White/Red9 Green/Black 18 Orange/Red

Product Construction: Conductor: •16thru12AWGfullyannealedstranded

tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedPVC •Colorcode:Seechartbelow

Jacket: •PVC,gray •Temperaturerange:-20°Cto+90°C

Applications: •Publicaddresssystems •Intercoms •Internaltelephones •Remotecontrolcircuits •SuitableforEIARS-232applications •Suggestedvoltagerating:300volts

Compliances: •NECArticle725TypeCL3(UL:75°C) •NECArticle800TypeCM(UL:75°C) •ULStyle2464(UL:80°C,300V) •ULStyle2587(UL:90°C,600V) •CSACMG(CSA:60°C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS

NOM. JACKETTHICKNESS NOMINAL O.D.

NOM.C-C

CAP.*pF/ftINCHES mm INCHES mm INCHES mm

NEC TYPE CM, UL STYLE 2464 (80°C, 300 VOLTS)

C2405A 2 16 19/.0117 0.021 0.53 0.032 0.81 0.260 6.81 30.5

C2406A 3 16 19/.0117 0.021 0.53 0.032 0.81 0.283 7.19 30.5

C2425A 4 16 19/.0117 0.021 0.53 0.032 0.81 0.306 7.77 30.5

C2434A 5 16 19/.0117 0.021 0.53 0.032 0.81 0.334 8.48 30.5

C2426A 7 16 19/.0117 0.021 0.53 0.032 0.81 0.363 9.25 30.5

C2443A 8 16 19/.0117 0.021 0.53 0.032 0.81 0.393 10.03 30.5

C2435A 9 16 19/.0117 0.021 0.53 0.032 0.81 0.423 10.80 30.5

C2427A 12 16 19/.0117 0.021 0.53 0.032 0.81 0.476 12.17 30.5

C2428A 15 16 19/.0117 0.021 0.53 0.032 0.81 0.530 13.46 30.5

C2429A 19 16 19/.0117 0.021 0.53 0.032 0.81 0.559 14.33 30.5

C2436A 25 16 19/.0117 0.021 0.53 0.032 0.81 0.657 16.69 30.5

NEC TYPE CL3, UL STYLE 2587 (90°C, 600 VOLTS)

C2409A† 2 14 19/.0147 0.030 0.81 0.032 0.81 0.326 8.51 29.0

C2430A 4 14 19/.0147 0.032 0.81 0.032 0.81 0.391 9.93 28.2

C2437A 5 14 19/.0147 0.032 0.81 0.032 0.81 0.428 10.87 28.2

C2431A 7 14 19/.0147 0.032 0.81 0.032 0.81 0.469 11.91 28.2

C2410A 2 12 19/0.0185 0.032 0.81 0.032 0.81 0.366 9.40 31.0

C2440A 4 12 19/0.0185 0.032 0.81 0.032 0.81 0.437 11.02 31.0*Capacitance between conductors†CL3,UL2587,CSACMHOnly

Page 26: Cross-Reference & Online Spec Sheets - Datasheet Archive

15

Communication & Control Cable, Multi-Conductor Electronics

Color Code ChartNO. OFCOND. COLOR

1 Black

2 White

3 Red

4 Green

Product Construction: Conductor: •18AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedFEP •Colorcode:Seechartbelow

Jacket: •Flexguard®PVC,naturalorasrequested •Temperaturerange:-20°Cto+75°C

Applications: •Audiosystems •Remotecontrolcircuits •Processcontrolandinstrumentation •Suggestedvoltagerating:300volts

Compliances: •NECArticle800(UL:75°C,300V) •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Fire-retardant,low-smokejacket

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Multi-Conductor, Unshielded NEC Type CMP (UL) c(UL)

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS

NOM. JACKETTHICKNESS NOMINAL O.D. NOM. C-C

CAP.*pF/ftINCHES mm INCHES mm INCHES mm

C8102 4 18 19/30 TC 0.007 0.18 0.014 0.36 0.178 4.52 21.5

*Capacitance between conductors

Page 27: Cross-Reference & Online Spec Sheets - Datasheet Archive

16

Electronics Communication & Control Cable, Multi-Conductor

Multi-Conductor, Unshielded NEC Type CMP (UL) c(UL) and/or CL2P

Product Construction: Conductor: •22thru14AWGfullyannealedstranded

tinned or bare copper per ASTM B-3, B-8 or B-33

Insulation: •Premium-grade,coIor-codedFlexguard®

PVC •Colorcode:Seechartbelow

Jacket: •Fluoropolymer,natural •Temperaturerange:-20°Cto+75°C •Sequentialfootagemarkedtofacilitate

installation •Includesripcord

Applications: •Intercomsystems •Backgroundmusic •Audiosystems •Power-limitedcontrolcircuits •Suggestedvoltagerating:150volts

Compliances: •NECArticle725(UL:75°C,150V) •NECArticle800(UL:75°C,300V) •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Abrasion-,chemical-andwater-resistant

jacket

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM.C-C

CAP.*pF/ftINCHES mm INCHES mm INCHES mm

22 AWG CONDUCTORS

C3105† 2 22 7/30 TC 0.006 0.15 0.010 0.25 0.089 2.26 29.0

C3106† 4 22 7/30 TC 0.006 0.15 0.010 0.25 0.121 3.07 29.0

18 AWG CONDUCTORS

C3102 2 18 7/26 BC 0.008 0.20 0.010 0.25 0.123 3.12 31.0

C3190 3 18 7/26 BC 0.008 0.20 0.010 0.25 0.143 3.63 31.0

C3103 4 18 7/26 BC 0.008 0.20 0.010 0.25 0.163 4.14 31.0

C3134 5 18 7/26 BC 0.008 0.20 0.010 0.25 0.187 4.75 30.8

C3192 6 18 7/26 BC 0.008 0.20 0.010 0.25 0.198 5.03 31.0

C3191 8 18 7/26 BC 0.008 0.20 0.010 0.25 0.223 5.66 31.0

C3178 10 18 7/26 BC 0.008 0.20 0.010 0.25 0.244 6.19 31.0

C3179 12 18 7/26 BC 0.008 0.20 0.010 0.25 0.263 6.68 31.0

16 AWG CONDUCTORS

C3193 2 16 19/.0117 BC 0.008 0.20 0.010 0.25 0.141 3.58 33.0

C3194 3 16 7/.0192 BC 0.008 0.20 0.010 0.25 0.164 4.17 33.0

C3195 4 16 7/.0192 BC 0.008 0.20 0.010 0.25 0.187 4.75 33.0

14 AWG CONDUCTORS

C3126† 2 14 19/.0147 BC 0.010 0.25 0.010 0.25 0.168 4.27 35.0

12 AWG CONDUCTORSC3135† 2 12 19/.0185 BC 0.010 0.25 0.010 0.25 0.238 6.05 37.0

*Capacitance between conductors

†CL2P only

Color Code ChartNO. OFCOND. COLOR

1 Black

2 White

3 Red

4 Green

5 Brown

6 Blue

7 Orange

8 Yellow

9 Violet

10 Gray

11 Pink

12 Tan

Page 28: Cross-Reference & Online Spec Sheets - Datasheet Archive

17

Communication & Control Cable, Multi-Conductor Electronics

Multi-Conductor, Unshielded NEC Type CMP (UL) c(UL) and/or CL3P

Product Construction: Conductor: •22thru12AWGfullyannealedsolid,

stranded tinned or bare copper per ASTM B-3, B-8 or B-33

Insulation: •Premium-grade,coIor-codedFlexguard®

PVC •Colorcode:Seechartbelow

Jacket: •Flexguard®PVC,natural •Temperaturerange:0°Cto+75°C •Sequentialfootagemarkedtofacilitate

installation •Includesripcord

Applications: •Intercomsystems •Backgroundmusic •Audiosystems •Power-limitedcontrolcircuits •Suggestedvoltagerating:150volts

Compliances: •NECArticle725(UL:75°C,150V) •NECArticle800(UL:75°C,300V) •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Flexible •Easytoterminate

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Color Code ChartNO. OFCOND. COLOR

1 Black

2 White

3 Red

4 Green

5 Brown

6 Blue

7 Orange

8 Yellow

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM.* C-CCAP.pF/ftINCHES mm INCHES mm INCHES mm

22 AWG CONDUCTORSC3115 2 22 7/32 TC 0.008 0.20 0.015 0.38 0.122 3.10 30.0

C3116 4 22 7/32 TC 0.008 0.20 0.015 0.38 0.141 3.58 30.0

18 AWG CONDUCTORSC3110 2 18 Solid BC 0.008 0.20 0.015 0.38 0.142 3.61 37.0

C3114 3 18 Solid BC 0.008 0.20 0.015 0.38 0.151 3.84 37.0

C3111 4 18 Solid BC 0.008 0.20 0.015 0.38 0.166 4.22 37.0

C3117 5 18 Solid BC 0.008 0.20 0.015 0.38 0.182 4.62 37.0

C3118 6 18 Solid BC 0.008 0.20 0.015 0.38 0.199 5.05 37.0

C3119 8 18 Solid BC 0.008 0.20 0.015 0.38 0.216 5.49 37.0

C3112 2 18 7/26 BC 0.008 0.20 0.015 0.38 0.156 3.96 35.0

C3120 3 18 7/26 BC 0.008 0.20 0.015 0.38 0.166 4.22 35.0

C3113 4 18 7/26 BC 0.008 0.20 0.015 0.38 0.182 4.62 35.0

C3125 5 18 7/26 BC 0.008 0.20 0.015 0.38 0.200 5.08 54.6

C3121 6 18 7/26 BC 0.008 0.20 0.015 0.38 0.216 5.49 35.0

C3122 8 18 7/26 BC 0.008 0.20 0.015 0.38 0.239 6.07 35.0

C3123 10 18 7/26 BC 0.008 0.20 0.015 0.38 0.278 7.06 35.0

C3124 12 18 7/26 BC 0.008 0.20 0.015 0.38 0.287 7.29 35.0

16 AWG CONDUCTORSC3127 2 16 19/.0117 BC .009 .227 0.015 0.38 0.178 4.52 40.0

14 AWG CONDUCTORSC3128† 2 14 19/.0147 BC 0.010 0.20 0.015 0.38 0.212 5.38 40.0

12 AWG CONDUCTORSC3129† 2 12 19/.0185 BC 0.010 0.20 0.015 0.38 0.254 6.45 43.0

*Capacitance between conductors

†CL3P only

Page 29: Cross-Reference & Online Spec Sheets - Datasheet Archive

18

Electronics Communication & Control Cable, Multi-Conductor

Multi-Conductor, Unshielded AWMStyle2464,CSATypeAWMI/IIA/B,NEC/CECTypeCMG(CSAC/US)

Product Construction: Conductor: •22AWGfullyannealed,strandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedPVC •Colorcode:Seechartsbelow

Jacket: •PVC,gray •Temperaturerange:-20°Cto+105°C

Applications: •Publicaddresssystems •Intercoms •Internaltelephones •Remotecontrolcircuits •SuitableforEIARS-232applications •Suggestedvoltagerating:300or600

volts

Features: •Easytoterminate •Excellentelectricalproperties •Tinnedconductorsprovideexcellent

corrosion resistance •Assistssolderingapplications

Compliances: •AWMStyle2464(CSA:80˚C,300V) •CSATypeAWM(105˚C,600V) •CSACertifiedCMGtoharmonized

standard UL444 and CSA 22.2 No. 214 •NEC/CECTypeCMG(CSA:105˚C,300V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetCSA70,000BTU

VerticalTrayFlameTest •PassesCSAFT4verticalflametest

Packaging: •PleasecontactCustomerServicefor

packaging and color optionsColor Code Chart 2 Per ICEA – For cables of 15 thru 50 conductors

NO. OFCOND. COLOR

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 18 Orange/Red 35 White/Red/Orange2 White 19 Blue/Red 36 Orange/White/Blue3 Red 20 Red/Green 37 White/Red/Blue4 Green 21 Orange/Green 38 Black/White/Green5 Orange 22 BlackWhite/Red 39 White/Black/Green6 Blue 23 White/Black/Red 40 Red/White/Green7 White/Black 24 Red/Black/White 41 Green/White/Blue8 Red/Black 25 Green/Black/White 42 Orange/Red/Green9 Green/Black 26 Orange/Black/White 43 Blue/Red/Green

10 Orange/Black 27 Blue/Black/White 44 Black/White/Blue11 Blue/Black 28 Black/Red/Green 45 White/Black/Blue12 Black/White 29 White/Red/Green 46 Red/White/Blue13 Red/White 30 Red/Black/Green 47 Green/Orange/Red14 Green/White 31 Green/Black/Orange 48 Orange/Red/Blue15 Blue/White 32 Orange/Black/Green 49 Blue/Red/Orange16 Black/Red 33 Blue/White/Orange 50 Black/Orange/Red17 White/Red 34 Black/White/Orange

Color Code Chart 1– For cables up to and including 12 conductorsNO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 7 Orange2 White 8 Yellow3 Red 9 Violet4 Green 10 Gray5 Brown 11 Pink6 Blue 12 Tan

CATALOG NUMBER

NO. OF

COND.AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS

NOM. JACKETTHICKNESS NOMINAL O.D.

COLORCODE

NOM.C-C

CAP.*pF/ftINCHES mm INCHES mm INCHES mm

C4100A 2 22 7/30 0.010 0.25 0.032 0.81 0.165 4.19 Black/Red 27.5

C4101A 3 22 7/30 0.010 0.25 0.032 0.81 0.176 4.47Black/Red/Green

27.5

C4102A 4 22 7/30 0.010 0.25 0.032 0.81 0.189 4.80 1 27.5C4103A 5 22 7/30 0.010 0.25 0.032 0.81 0.203 5.16 1 27.5C4104A 6 22 7/30 0.010 0.25 0.032 0.81 0.208 5.28 1 27.5C4105A 7 22 7/30 0.010 0.25 0.032 0.81 0.218 5.54 1 27.5C4106A 8 22 7/30 0.010 0.25 0.032 0.81 0.234 5.94 1 27.5C4107A 9 22 7/30 0.010 0.25 0.032 0.81 0.249 6.32 1 27.5C4108A 10 22 7/30 0.010 0.25 0.032 0.81 0.268 6.81 1 27.5C4109A 12 22 7/30 0.010 0.25 0.032 0.81 0.276 7.01 1 27.5C4110A 15 22 7/30 0.010 0.25 0.032 0.81 0.303 7.70 2 27.5C4111A 18 22 7/30 0.010 0.25 0.032 0.81 0.318 8.08 2 27.5C4112A 20 22 7/30 0.010 0.25 0.032 0.81 0.334 8.48 2 27.5C4113A 25 22 7/30 0.010 0.25 0.032 0.81 0.368 9.35 2 27.5C4114A 30 22 7/30 0.010 0.25 0.032 0.81 0.389 9.88 2 27.5C4115A 40 22 7/30 0.010 0.25 0.032 0.81 0.434 11.02 2 27.5C4116A 50 22 7/30 0.010 0.25 0.032 0.81 0.489 12.42 2 27.5

*Capacitance between conductors

Page 30: Cross-Reference & Online Spec Sheets - Datasheet Archive

19

Communication & Control Cable, Multi-Conductor Electronics

Multi-Conductor, Unshielded AWMStyle2464,CSATypeAWMI/IIA/B,NEC/CECTypeCMG(CSAC/US)

Product Construction: Conductor: •20or18AWGfullyannealed,stranded

tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedPVC •Colorcode:Seechartsbelow

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+105°C

Applications: •Publicaddresssystems •Intercoms •Internaltelephones •Remotecontrolcircuits •SuitableforEIARS-232applications •Suggestedvoltagerating:300or600

volts

Features: •Easytoterminate •Excellentelectricalproperties •Tinnedconductorsprovideexcellent

corrosion resistance •Assistssolderingapplications

Compliances: •AWMStyle2464(CSA:80˚C,300V) •CSATypeAWM(105˚C,600V) •CSACertifiedCMGtoharmonized

standard UL444 and CSA 22.2 No. 214 •NEC/CECTypeCMG(CSA:105˚C,300V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetCSA70,000BTU

VerticalTrayFlameTest •PassesCSAFT4verticalflametest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OF

COND.AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D. COLOR

CODE

NOM.C-C

CAP.*pF/ftINCHES mm INCHES mm INCHES mm

C4117A 2 20 7/28 0.016 0.41 0.032 0.81 0.206 5.23 Black/Red 25.0

C4118A 3 20 7/28 0.016 0.41 0.032 0.81 0.216 5.49 1 25.0

C4119A 4 20 7/28 0.016 0.41 0.032 0.81 0.235 5.97 1 25.0

C4120A 5 20 7/28 0.016 0.41 0.032 0.81 0.254 6.45 1 25.0

C4121A 7 20 7/28 0.016 0.41 0.032 0.81 0.275 6.99 1 25.0

C4122A 9 20 7/28 0.016 0.41 0.032 0.81 0.317 8.05 1 25.0

C4123A 12 20 7/28 0.016 0.41 0.032 0.81 0.354 8.99 2 25.0

C4124A 15 20 7/28 0.016 0.41 0.032 0.81 0.392 9.96 2 25.0

C4125A 2 18 16/30 0.016 0.41 0.032 0.81 0.224 5.69 Black/Red 27.5

C4214A 2 18 16/30 0.016 0.41 0.032 0.81 0.224 5.69 1 27.5

C4126A 3 18 16/30 0.016 0.41 0.032 0.81 0.236 5.99 1 27.5

C4127A 4 18 16/30 0.016 0.41 0.032 0.81 0.258 6.55 1 27.5

C4128A 5 18 16/30 0.016 0.41 0.032 0.81 0.280 7.11 1 27.5

C4206A 6 18 16/30 0.016 0.41 0.032 0.81 0.304 7.72 1 27.5

C4129A 7 18 16/30 0.016 0.41 0.032 0.81 0.309 7.85 1 27.5

C4130A 9 18 16/30 0.016 0.41 0.032 0.81 0.358 9.09 1 27.5

C4131A 12 18 16/30 0.016 0.41 0.032 0.81 0.401 10.19 2 27.5

C4132A 15 18 16/30 0.016 0.41 0.032 0.81 0.445 11.30 2 27.5

C4133A 19 18 16/30 0.016 0.41 0.032 0.81 0.469 11.91 2 27.5

C4134A 25 18 16/30 0.016 0.41 0.032 0.81 0.549 13.94 2 27.5*Capacitance between conductors

Color Code Chart 2 Per ICEA - For cables of 12 thru 25 conductors

NO. OFCOND. COLOR

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 10 Orange/Black 19 Blue/Red2 White 11 Blue/Black 20 Red/Green3 Red 12 Black/White 21 Orange/Green4 Green 13 Red/White 22 Black/White/Red5 Orange 14 Green/White 23 White/Black/Red6 Blue 15 Blue/White 24 Red/Black/White7 White/Black 16 Black/Red 25 Green/Black/White8 Red/Black 17 White/Red9 Green/Black 18 Orange/Red

Color Code Chart 1 - For cables up to and including 9 conductors

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 6 Blue2 White 7 Orange3 Red 8 Yellow4 Green 9 Violet5 Brown

Page 31: Cross-Reference & Online Spec Sheets - Datasheet Archive

20

Electronics Communication & Control Cable, Multi-Conductor

Multi-Conductor, Unshielded AWMStyles2464,2587,CSATypeAWMI/IIA/B,NEC/CECTypeCMG(CSAC/US), or NEC Type CL2

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM.C-C

CAP.*pF/ftINCHES mm INCHES mm INCHES mm

AWM STYLE 2464, CSA TYPE AWM, CSA C/US TYPE CMG

C4135A 2 16 19/.0117 0.021 0.53 0.032 0.81 0.268 6.81 27.0

C4136A 3 16 19/.0117 0.021 0.53 0.032 0.81 0.283 7.19 27.0

C4137A 4 16 19/.0117 0.021 0.53 0.032 0.81 0.306 7.77 27.0

C4138A 5 16 19/.0117 0.021 0.53 0.032 0.81 0.334 8.48 27.0

C4139A 7 16 19/.0117 0.021 0.53 0.032 0.81 0.364 9.25 27.0

C4140A 8 16 19/.0117 0.021 0.53 0.032 0.81 0.395 10.03 27.0

C4141A 9 16 19/.0117 0.021 0.53 0.032 0.81 0.425 10.80 27.0

C4142A 12 16 19/.0117 0.021 0.53 0.032 0.81 0.479 12.17 27.0

C4143A 15 16 19/.0117 0.021 0.53 0.032 0.81 0.530 13.46 27.0

C4144A 19 16 19/.0117 0.021 0.53 0.032 0.81 0.564 14.33 27.0

C4145A 25 16 19/.0117 0.021 0.53 0.032 0.81 0.657 16.69 27.0

AWM STYLE 2587, CSA TYPE AWM (FT4), NEC TYPE CL2**

C4146A 2 14 19/.0147 0.032 0.81 0.032 0.81 0.334 8.48 25.0

C4147A 4 14 19/.0147 0.032 0.81 0.032 0.81 0.391 9.93 25.0

C4148A 5 14 19/.0147 0.032 0.81 0.032 0.81 0.428 10.87 25.0

C4149A 7 14 19/.0147 0.032 0.81 0.032 0.81 0.469 11.91 25.0

C4150A 2 12 19/.0185 0.032 0.81 0.032 0.81 0.370 9.40 29.4

C4151A 4 12 19/.0185 0.032 0.81 0.032 0.81 0.434 11.02 29.4

* Capacitance between conductors

Color Code Chart Per ICEANO. OFCOND. COLOR

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 10 Orange/Black 19 Blue/Red

2 White 11 Blue/Black 20 Red/Green

3 Red 12 Black/White 21 Orange/Green

4 Green 13 Red/White 22 Black/White/Red

5 Orange 14 Green/White 23 White/Black/Red

6 Blue 15 Blue/White 24 Red/Black/White

7 White/Black 16 Black/Red 25 Green/Black/White

8 Red/Black 17 White/Red

9 Green/Black 18 Orange/Red

Product Construction: Conductor: •16thru12AWGfullyannealed,stranded

tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedPVC •Colorcode:Seechartbelow

Jacket: •PVC,gray •Temperaturerange:-20°Cto+105°C

Applications: •Publicaddresssystems •Intercoms •Internaltelephones •Remotecontrolcircuits •SuitableforEIARS-232applications •Suggestedvoltagerating:300or600

volts

Features: •Easytoterminate •Excellentelectricalproperties •Tinnedconductorsprovideexcellent

corrosion resistance •Assistssolderingapplications

Compliances: •AWMStyle2464(CSAorUL:80˚C,

300V) •AWMStyle2587(CSA:90˚C,600V) •CSATypeAWM(105˚C,600V) •CSACertifiedCMGtoharmonized

standard UL444 and CSA 22.2 No. 214 •NEC/CECTypeCMG(CSA:105˚C,300V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetCSA70,000BTU

VerticalTrayFlameTest •PassesCSAFT4VerticalFlameTest •ULCertifiedCL2toStandardUL13** •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Page 32: Cross-Reference & Online Spec Sheets - Datasheet Archive

21

Communication & Control Cable, Multi-Conductor Electronics

Multi-Conductor, Rubber, Unshielded

Product Construction: Conductor: •20AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedrubber •Colorcode:Seechartbelow

Jacket: •Rubber,black •Temperaturerange:-20˚Cto+60˚C

Applications: •Energymanagementsystems •Controlcircuits •Firealarmcontrol •Broadcastandstudiorequirements •Suggestedvoltagerating:350volts

Features: •Excellentimpactresistance •Highlevelofabrasionresistance •Highflexibility •Excellentmechanicalstrength •Excellentmoistureresistance

Compliances: •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

INCHES mm INCHES mm INCHES mm

C3602 2 20 26/34 0.020 0.51 0.035 0.89 0.230 5.84

C3603 3 20 26/34 0.020 0.51 0.035 0.89 0.255 6.48

C3604 4 20 26/34 0.020 0.51 0.035 0.89 0.260 6.60

C3605 5 20 26/34 0.020 0.51 0.035 0.89 0.300 7.62

C3606 6 20 26/34 0.020 0.51 0.035 0.89 0.315 8.00

C3607 7 20 26/34 0.020 0.51 0.035 0.89 0.347 8.81

C3608 8 20 26/34 0.020 0.51 0.035 0.89 0.260 9.14

C3610 10 20 26/34 0.020 0.51 0.035 0.89 0.410 10.41

Color Code ChartNO. OFCOND. COLOR

1 Black

2 White

3 Red

4 Green

5 Blue

6 Brown

7 Yellow

8 Orange

9 Gray

10 Violet

Page 33: Cross-Reference & Online Spec Sheets - Datasheet Archive

22

Electronics Communication & Control Cable, Multi-Conductor

Power-Limited Tray Cable, Unshielded NEC Type PLTC

Product Construction: Conductor: •22thru12AWGfullyannealedstranded

tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedPVC •Colorcode:Seechartbelow

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+105°C

Applications: •Cabletrayinstallations •Powerlimitedcircuits •Intercomsystems •Businessmachines •Cashregisters •Automaticvalvecontrolsystems •Irrigationsystems •Suggestedvoltagerating:300volts •Burglaralarms

Features: •Sunlight-resistantPVCjacket •ULratedforcabletrayuse

Compliances: •NECArticle725Power-LimitedTray

Cable(UL:105°C,300V) •RoHSCompliantDirective2002/95/EC •MeetsUL70,000BTUVerticalTray

Flame Test

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS

NOM. JACKETTHICKNESS NOMINAL O.D.

NOM.C-C

CAP.*pF/ftINCHES mm INCHES mm INCHES mm

C0431A 2 22 7/30 0.013 0.33 0.037 0.94 0.190 4.83 27.5

C0432A 3 22 7/30 0.013 0.33 0.037 0.94 0.198 5.03 27.5

C0433A 2 20 7/28 0.013 0.33 0.037 0.94 0.206 5.23 30.5

C0434A 3 20 7/28 0.013 0.33 0.037 0.94 0.216 5.49 30.5

C0435A 2 18 16/30 0.015 0.38 0.037 0.94 0.226 5.74 31.5

C0436A 3 18 16/30 0.015 0.38 0.037 0.94 0.237 6.02 31.5

C0444A 4 18 16/30 0.015 0.38 0.037 0.94 0.257 6.53 31.5

C0437A 2 16 19/.0117 0.013 0.33 0.037 0.94 0.243 6.17 37.0

C0438A 3 16 19/.0117 0.013 0.33 0.037 0.94 0.250 6.35 37.0

C0439A 2 14 19/.0147 0.013 0.33 0.042 1.07 0.288 7.32 40.5

C0440A 3 14 19/.0147 0.013 0.33 0.042 1.07 0.290 7.37 40.5

C0441A 2 12 19/.0185 0.013 0.33 0.042 1.07 0.315 8.00 44.0

*Capacitance between conductors

Color Code ChartNO. OFCOND. COLOR

1 Black

2 Red

3 White

4 Green

Page 34: Cross-Reference & Online Spec Sheets - Datasheet Archive

23

Communication & Control Cable, Multi-Conductor Electronics

Multi-Conductor, Foil Shield NECTypeCL2andCM(UL)c(UL)CMH

Product Construction: Conductor: •24thru12AWGfullyannealedsolidor

stranded tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-coded

polyethylene •Premium-grade,coIor-coded

polypropylene •Colorcode:Seechartsbelow

Shield: •100%Flexfoil® aluminum/polyester,

25%overlap,foilfacingout •Strandedtinnedcopperdrainwire

Jacket: •PVC,gray •Temperaturerange:-20°Cto+75°C

Applications: •Recordingstudiosandsoundstages •Broadcastandsoundsystems •Computers •Industrialequipmentcontrol •Suggestedvoltagerating:300or600

volts

Features: •Excellentelectricalproperties •Superiorshieldingeffectiveness •25%shieldoverlapprovidesexcellent

shielding efficiency •Goodflexibility

Compliances: •ULStyle2092(UL:60°C,300V) •ULStyle2093(UL:60°C,300V) •ULStyle2094(UL:60°C,300V) •ULStyle2106(UL:60°C,600V) •ULStyle2107(UL:60°C,600V) •ULStyle2464(UL:80°C,300V) •NECArticle725TypeCL2(UL:75°C) •NECArticle800TypeCM(UL:75°C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •CSACMH(CSA:60˚C) •PassesCSACMHFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D. NOM. CAP.***

pF/ft

INCHES mm INCHES mm INCHES mm A B

UL STYLE 2092, CM (UL) C(UL) CMH, 300VC2513A 2 24 7/32 0.016 0.41 0.026 0.66 0.167 4.24 18.0 33.0

C2514A 2 22 7/30 0.016 0.41 0.020 0.51 0.167 4.24 20.0 36.0

C2524A 2 20 7/28 0.016 0.41 0.020 0.51 0.183 4.65 22.5 40.5

C2534A 2 18 16/30 0.016 0.41 0.020 0.51 0.201 5.21 25.5 45.5

PolyethyleneInsulation,ColorCodeChart#1

UL STYLE 2093, CM (UL) c(UL) CMH, 300VC2526A 3 22 7/30 0.016 0.41 0.030 0.76 0.196 4.98 18.5 33.5

C2528A 3 20 7/28 0.016 0.41 0.030 0.76 0.210 5.34 21.0 37.5

C2525A 3 20 7/28 0.016 0.41 0.030 0.76 0.213 5.41 21.0 37.0

C2535A 3 18 16/30 0.016 0.41 0.020 0.51 0.213 5.56 23.0 41.0

PolyethyleneInsulation,ColorCodeChart#1

UL STYLE 2094, CM (UL) c(UL) CMH, 300VC2523A 4 22 7/30 0.016 0.41 0.030 0.76 0.213 5.41 18.5 33.5

C2555A 4 20 7/28 0.016 0.41 0.030 0.76 0.234 5.94 20.5 36.5

PolyethyleneInsulation,ColorCodeChart#1

UL STYLE 2106, CSA, 600VC2536A* 2 16 19/.0117 0.031 0.79 0.032 0.81 0.307 7.80 20.0 36.0

C2538A** 2 14 19/.0147 0.031 0.79 0.032 0.81 0.335 8.51 23.0 42.0

C2539A** 2 12 19/.0185 0.032 0.81 0.032 0.81 0.376 9.55 26.0 46.0

*CM(UL)c(UL)CMH ** CL2 PolyethyleneInsulation,ColorCodeChart#1

UL STYLE 2107, CM (UL) c(UL) CMH, 600VC2537A 3 16 19/.0117 0.031 0.79 0.032 0.81 0.325 8.26 19.0 34.0

PolyethyleneInsulation,ColorCodeChart#1

UL STYLE 2464, CL2/CM (UL) c(UL) CMH, 300VC2540A 2 20 7/28 0.013 0.33 0.032 0.81 0.194 4.9 49.7 89.5

PVCInsulation,ColorCodeChart#2

CM (UL) c(UL) CMH, 300VC2515A 2 22 Solid 0.007 0.18 0.020 0.51 0.124 3.15 30.0 55.0

C2516A 2 22 7/30 0.008 0.20 0.020 0.51 0.137 3.48 28.0 51.0

C2517A 3 22 7/30 0.008 0.20 0.020 0.51 0.144 3.36 25.0 45.0

PolypropyleneInsulation,ColorCodeChart#2 ***A – Capacitance between conductors ***B – Capacitance between one conductor and other conductors connected to shield

Color Code Chart 1NO. OFCOND. COLOR

1 Black2 Natural3 Red4 Green

Color Code Chart 2NO. OFCOND. COLOR

1 Black2 Red3 Clear

Page 35: Cross-Reference & Online Spec Sheets - Datasheet Archive

24

Electronics Communication & Control Cable, Multi-Conductor

Multi-Conductor, Foil Shield UL2092,NECTypeCM(UL)c(UL)CMH

Product Construction: Conductor: •22thru18AWGfullyannealedstranded

tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-coded

polyethylene or polypropylene •Colorcode:Seechartsbelow

Shield: •100%aluminum/polyesterfoil“bonded”

to jacket, foil facing in •Strandedtinnedcopperdrainwire

Jacket: •PVC,gray •Temperaturerange:-20°Cto+75°C

Applications: •100%shieldedcablewhereRFshielding

is required •Controlcircuits •Dataandsignaltransmission •Computerinterconnections •Suggestedvoltagerating:300volts

Features: •Thejacketandshieldare“bonded”for

ease of removal on automatic stripping equipment

Compliances: •NECArticle800TypeCM(UL:75°C) •ULStyle2092(UL:60°C,300V) •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •CSACMH(CSA:60˚C) •RoHSCompliantDirective2002/95/EC •PassesCSACMHFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

UL STYLE 2092, CM (UL) C(UL) CMH, 300V

C2518A 2 22 7/30 0.016 0.41 0.026 0.66 0.181 4.60 20.0 36.0

C2519A 2 20 7/28 0.016 0.41 0.028 0.71 0.201 5.11 21.5 38.5

C2521A 2 18 16/30 0.018 0.46 0.028 0.71 0.229 5.82 23.5 43.0

PolyethyleneInsulation,ColorCodeChart#1

CM (UL) c(UL) CMH, 300V

C2520A 2 22 7/30 0.008 0.20 0.020 0.51 0.137 3.48 28.0 50.0

PolypropyleneInsulation,ColorCodeChart#2 *A – Capacitance between conductors *B – Capacitance between one conductor and other conductors connected to shield

Color Code Chart 1NO. OFCOND. COLOR

1 Black

2 Natural

Color Code Chart 2NO. OFCOND. COLOR

1 Black

2 Red

Page 36: Cross-Reference & Online Spec Sheets - Datasheet Archive

25

Communication & Control Cable, Multi-Conductor Electronics

Multi-Conductor, Foil Shield UL 2464, NEC Type CM (UL) c(UL), CSA CMG

Product Construction: Conductor: •18AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedS-RPVC •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester,

25%overlap,foilfacingout •Strandedtinnedcopperdrainwire

Jacket: •PVC,gray •Temperaturerange:-20°Cto+80°C

Applications: •Audio,broadcast,instrumentationand

sound systems •Suggestedvoltagerating:300volts

Compliances: •NECArticle800TypeCM(UL:75˚C) •ULStyle2464(UL:80˚C,300V) •CSACMG(60°C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C2543A 4 18 19/30 0.010 0.25 0.032 0.81 0.238 6.05 47 84.5

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFCOND. COLOR

1 Black

2 Red

3 White

4 Green

Page 37: Cross-Reference & Online Spec Sheets - Datasheet Archive

26

Electronics Communication & Control Cable, Multi-Conductor

Multi-Conductor, Foil Shield NEC Type CMP (UL) c(UL)

Product Construction: Conductor: •18AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedFEP •Colorcode:Seechartbelow

Separator: •Polyestertapewith25%overlap

Shield: •100%Flexfoil® aluminum/polyester foil

with25%overlap •Strandedtinnedcopperdrainwire

Jacket: •FEP,redorasrequested •Temperaturerange:-40°Cto+200°C

Applications: •Computersystems •Remotecontrolcircuits •Processcontrolandinstrumentation •Suggestedvoltagerating:300volts

Compliances: •NECArticle800 •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Fire-retardant,low-smokejacket •Suitableforoutdooranddirectburial •Chemical-resistant

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C8106 3 18 19/30 TC 0.007 0.18 0.014 0.36 0.178 4.27 54.0 95.0

C8114 4 18 19/30 TC 0.007 0.18 0.014 0.36 0.185 4.70 30.0 55.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFCOND. COLOR

1 Black

2 White

3 Red

4 Green

Page 38: Cross-Reference & Online Spec Sheets - Datasheet Archive

27

Communication & Control Cable, Multi-Conductor Electronics

Multi-Conductor, Foil Shield NEC Type CMP (UL) c(UL) and/or CL2P

Product Construction: Conductor: •22thru16AWGfullyannealedstranded

tinned or bare copper per ASTM B-3, B-8 or B-33

•ClassBstrandingperASTMB-8

Insulation: •Premium-grade,coIor-codedFlexguard®

•Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester foil,

with25%overlap •Strandedtinnedcopperdrainwire

Jacket: •Fluoropolymer,natural •Temperaturerange:-20°Cto+75°C •Sequentialfootagemarkedtofacilitate

installations •Strandedtinnedcopperdrainwire •Includesripcord

Applications: •Intercomsystems •Backgroundmusic •Audiosystems •Power-limitedcontrolcircuits •Suggestedvoltagerating:150volts

Compliances: •NECArticle725(UL:75°C,150V) •NECArticle800(UL:75°C,300V) •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Abrasion-,chemical-andwater-resistant

jacket

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.**pF/ft

INCHES mm INCHES mm INCHES mm A B

22 AWG CONDUCTORS

C3154* 2 22 7/30 TC 0.006 0.15 0.010 0.25 0.103 2.62 51.0 92.0

C3310* 3 22 7/30 TC 0.006 0.15 0.010 0.25 0.116 2.95 45.0 81.0

C3155* 4 22 7/30 TC 0.006 0.15 0.010 0.25 0.130 3.30 45.0 81.0

C3311* 6 22 7/30 TC 0.006 0.15 0.010 0.25 0.152 3.86 40.0 73.0

20 AWG CONDUCTORS

C3320* 2 20 7/28 TC 0.007 0.18 0.010 0.25 0.120 3.05 53.0 96.0

C3321* 3 20 7/28 TC 0.007 0.18 0.010 0.25 0.136 3.45 46.0 84.0

C3322* 4 20 7/28 TC 0.007 018 0.010 0.25 0.153 3.89 46.0 84.0

18 AWG CONDUCTORS

C3162 2 18 7/26 BC 0.008 0.20 0.010 0.25 0.152 3.86 54.0 98.0

C3164 3 18 7/26 BC 0.008 0.20 0.010 0.25 0.158 4.01 47.0 85.0

C3163 4 18 7/26 BC 0.008 0.20 0.010 0.25 0.178 4.52 47.0 85.0

C3166 6 18 7/26 BC 0.008 0.20 0.010 0.25 0.212 5.38 43.0 76.0

C3180 8 18 7/26 BC 0.008 0.20 0.010 0.25 0.229 5.82 43.0 76.0

C3181 10 18 7/26 BC 0.008 0.20 0.010 0.25 0.273 6.93 43.0 76.0

C3182 12 18 7/26 BC 0.008 0.20 0.012 0.30 0.285 7.24 43.0 76.0

16 AWG CONDUCTORS

C3169 2 16 19/.0117 BC 0.008 0.20 0.010 0.25 0.181 4.60 62.0 112.0

C3340 3 16 7/.0192 BC 0.008 0.20 0.010 0.25 0.185 4.70 52.0 93.0

C3341 4 16 7/.0192 BC 0.008 0.20 0.010 0.25 0.210 5.16 52.0 93.0

*CL2P only**A – Capacitance between conductors**B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFCOND. COLOR

1 Black

2 White

3 Red

4 Green

5 Brown

6 Blue

7 Orange

8 Yellow

9 Violet

10 Gray

11 Pink

12 Tan

Page 39: Cross-Reference & Online Spec Sheets - Datasheet Archive

28

Electronics Communication & Control Cable, Multi-Conductor

Multi-Conductor, Foil Shield NEC Type CMP (UL) c(UL) and CL3P

Product Construction: Conductor: •22thru16AWGfullyannealedstranded

tinned or bare copper per ASTM B-3, B-8 or B-33

Insulation: •Premium-grade,coIor-codedFlexguard®

PVC •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester foil

with25%overlap,minimum •Strandedtinnedcopperdrainwire

Jacket: •Flexguard®PVC,natural •Temperaturerange:0°Cto+75°C •Sequentialfootagemarkedtofacilitate

installation •Includesripcord

Applications: •Intercomsystems •Backgroundmusic •Audiosystems •Power-limitedcontrolcircuits •Suggestedvoltagerating:150volts

Compliances: •NECArticle725(UL:75°C,150V) •NECArticle800(UL:75°C,300V) •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Flexible •Easytoterminate

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

22 AWG CONDUCTORS

C3158 2 22 7/30 TC 0.008 0.20 0.015 0.38 0.127 3.23 51.0 91.0

C3159 4 22 7/30 TC 0.008 0.20 0.015 0.38 0.146 3.71 45.0 81.0

18 AWG CONDUCTORS

C3060 2 18 Solid BC 0.008 0.20 0.015 0.38 0.148 3.76 67.0 120.0

C3061 4 18 Solid BC 0.008 0.20 0.015 0.38 0.171 4.34 58.0 104.0

C3062 2 18 7/26 BC 0.008 0.20 0.015 0.38 0.164 4.17 61.0 110.0

C3064 3 18 7/26 BC 0.008 0.20 0.015 0.38 0.169 4.29 53.0 96.0

C3063 4 18 7/26 BC 0.008 0.20 0.015 0.38 0.185 4.70 53.0 96.0

C3065 6 18 7/26 BC 0.010 0.25 0.015 0.38 0.230 5.84 48.0 86.0

C3183 10 18 7/26 BC 0.012 0.20 0.015 0.38 0.310 7.87 47.0 84.0

C3184 12 18 7/26 BC 0.010 0.25 0.015 0.38 0.308 7.82 52.5 94.6

16 AWG CONDUCTORS

C3068 2 16 19/.0117 BC 0.009 0.23 0.015 0.38 0.187 4.75 75.0 134.0*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFCOND. COLOR

1 Black

2 White

3 Red

4 Green

5 Brown

6 Blue

7 Orange

8 Yellow

9 Violet

10 Gray

11 Pink

12 Tan

Page 40: Cross-Reference & Online Spec Sheets - Datasheet Archive

29

Communication & Control Cable, Multi-Conductor Electronics

Multi-Conductor, Foil ShieldVariousAWMStyles,CSATypeAWMI/IIA/B, NEC/CEC Type CMG (CSA C/US), NEC Type CL2

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

AWM STYLE 20251, CSA TYPE AWM, CSA C/US TYPE CMG

C4152A 2 24 7/32 0.016 0.41 0.026 0.66 0.167 4.24 23.0 42.0

C4153A 2 22 7/30 0.016 0.41 0.026 0.66 0.179 4.55 21.0 38.0

C4154A 2 20 7/28 0.016 0.41 0.030 0.76 0.203 5.16 22.0 40.0

C4155A 2 18 16/30 0.018 0.46 0.030 0.76 0.233 5.92 24.0 43.0

C4156A 3 22 7/30 0.016 0.41 0.030 0.76 0.196 4.98 25.0 45.0

C4157A 3 20 7/28 0.016 0.41 0.030 0.76 0.210 5.33 27.0 51.0

C4158A 3 20 7/28 0.016 0.41 0.030 0.76 0.213 5.41 29.0 52.0

C4159A 3 18 16/30 0.018 0.46 0.030 0.76 0.247 6.27 22.0 40.0

C4160A 4 22 7/30 0.016 0.41 0.030 0.76 0.213 5.41 23.0 42.0

C4161A 4 20 7/28 0.016 0.41 0.030 0.76 0.234 5.94 26.0 74.0ColorCodeChart#1

AWM STYLE 2106, CSA TYPE AWM, CSA C/US TYPE CMG

C4162A 2 16 19/.0117 0.032 0.81 0.032 0.81 0.307 7.80 27.0 49.0

C4165A 3 16 19/.0117 0.032 0.81 0.032 0.81 0.326 8.28 26.0 46.0ColorCodeChart#1

NEC TYPE CL2, AWM STYLE 2464, CSA TYPE AWM

C4163A 2 14 41/30 0.020 0.51 0.032 0.81 0.298 7.57 31.0 56.0ColorCodeChart#3

NEC TYPE CL2, AWM STYLE 2106, CSA TYPE AWM

C4164A 2 12 19/.0185 0.032 0.81 0.040 1.02 0.390 9.90 35.0 63.0ColorCodeChart#1

AWM STYLE 20251, CSA TYPE AWM, CSA C/US TYPE CMG

C4167A 2 22 Solid 0.007 0.18 0.020 0.51 0.124 3.15 40.0 76.0

C4168A 2 22 7/30 0.008 0.20 0.020 0.51 0.137 3.48 34.0 67.0

C4169A 3 22 7/30 0.008 0.20 0.020 0.51 0.144 3.66 32.0 60.0

PolyethyleneInsulation,ColorCodeChart#2*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code Chart 1NO. OFCOND. COLOR

1 Black

2 Natural

3 Red

4 Green

Color Code Chart 2NO. OFCOND. COLOR

1 Black

2 Red

3 Clear

Color Code Chart 3NO. OFCOND. COLOR

1 Black

2 White

Product Construction: Conductor: •24thru12AWGfullyannealedsolidor

stranded tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-coded

polypropylene •Colorcode:Seechartsbelow

Shield: •100%Flexfoil® aluminum/polyester,

25%overlap,foilfacingout •Strandedtinnedcopperdrainwire

Jacket: •PVC,gray •Temperaturerange:-20°Cto+80°C

Applications: •Recordingstudiosandsoundstages •Broadcastandsoundsystems •Computers •Industrialequipmentcontrol •Suggestedvoltagerating:300or600

volts

Features: •Excellentelectricalproperties •Superiorshieldingeffectiveness •25%shieldoverlapprovidesexcellent

shielding efficiency •Goodflexibility

Compliances: •AWMStyle20251(CSA:60˚C,150V,

300Vpeak) •CSATypeAWM(80˚C,600V) •CSACertifiedCMGtoharmonized

standard UL444 and CSA 22.2 No. 214 •NECTypeCL2/CECTypeCMG(CSA:

80˚C,300V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetCSA70,000BTU

VerticalTrayFlameTest •PassesCSAFT4VerticalFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Page 41: Cross-Reference & Online Spec Sheets - Datasheet Archive

30

Electronics Communication & Control Cable, Multi-Conductor

Multi-Conductor, Foil ShieldAWM Styles 2464, CSA Type AWMI/IIA/B, NEC/CEC Type CMG (CSA C/US), or NEC Type CL2

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D. COLOR

CODE

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

AWM STYLE 2464, CSA TYPE AWM, CSA C/US TYPE CMG

C4192A 2 22 7/30 0.009 0.23 0.030 0.76 0.165 4.19 1 47.0 85.0

C4210A 2 22 7/30 0.009 0.23 0.032 0.81 0.165 4.19 2 47.0 85.0

C4193A 3 22 7/30 0.009 0.23 0.030 0.76 0.169 4.29 2 43.0 76.0

C4194A 4 22 7/30 0.009 0.23 0.030 0.76 0.181 4.60 2 43.0 76.0

C4207A 6 22 7/30 0.009 0.23 0.032 0.81 0.204 5.18 2 43.0 76.0

C4208A 8 22 7/30 0.009 0.23 0.032 0.81 0.223 5.66 2 43.0 76.0

C4166A 2 20 7/28 0.012 0.30 0.030 0.76 0.187 4.75 1 46.0 83.0

C4211A 2 20 7/28 0.012 0.30 0.032 0.81 0.191 4.85 2 46.0 83.0

C4195A 3 20 7/28 0.012 0.30 0.030 0.76 0.200 5.08 2 42.0 75.0

C4196A 4 20 7/28 0.012 0.30 0.030 0.76 0.216 5.49 2 42.0 75.0

C4197A 2 18 16/30 0.012 0.30 0.030 0.76 0.203 5.16 1 51.0 92.0

C4212A 2 18 16/30 0.012 0.30 0.032 0.81 0.205 5.20 2 51.0 92.0

C4198A 3 18 16/30 0.012 0.30 0.030 0.76 0.214 5.44 2 46.0 83.0

C4204A 4 18 16/30 0.012 0.30 0.032 0.81 0.236 5.99 2 46.0 83.0

C4205A 6 18 16/30 0.012 0.30 0.032 0.81 0.271 6.88 2 46.0 83.0

C4199A 2 16 19/.0117 0.010 0.25 0.030 0.76 0.218 5.54 1 62.0 112.0

C4213A 2 16 19/.0117 0.010 0.25 0.032 0.81 0.219 5.56 2 62.0 112.0

C4200A 3 16 19/.0117 0.010 0.25 0.030 0.76 0.230 5.84 2 58.0 104.0

AWM STYLE 2464, CSA TYPE AWM (FT4), NEC TYPE CL2*

C4201A 2 14 19/.0147 0.014 0.36 0.030 0.76 0.268 6.81 1 60.0 107.0

C4215A 2 14 19/.0147 0.014 0.36 0.030 0.76 0.268 6.81 2 60.0 107.0

C4202A 2 12 19/.0185 0.014 0.36 0.030 0.76 0.302 7.67 1 64.0 116.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code Chart 1NO. OFCOND. COLOR

1 Black

2 Red

Color Code Chart 2NO. OFCOND. COLOR

1 Black

2 White

3 Red

4 Green

5 Brown

6 Blue

7 Orange

8 Yellow

Product Construction: Conductor: •22thru12AWGfullyannealedstranded

tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedPVC •Colorcode:Seechartsbelow

Shield: •100%Flexfoil® aluminum/polyester,

25%overlap,foilfacingout •Strandedtinnedcopperdrainwire

Jacket: •PVC,gray •Temperaturerange:-20°Cto+105°C

Applications: •Recordingstudiosandsoundstages •Broadcastandsoundsystems •Industrialequipmentcontrol •SuitableforEIARS-232applications •Suggestedvoltagerating:300or600

volts

Features: •Superiorshieldingeffectiveness •25%shieldoverlapprovidesexcellent

shielding efficiency •Goodflexibility

Compliances: •AWMStyle2464(ULorCSA:80˚C,

300V) •CSATypeAWM(105˚C,600V) •CSACertifiedCMGtoharmonized

standard UL444 and CSA 22.2 No. 214 •NEC/CECTypeCMG(CSA:105˚C,300V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetCSA70,000BTU

VerticalTrayFlameTest •PassesCSAFT4VerticalFlameTest •ULCertifiedCL2toStandardUL13*

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Page 42: Cross-Reference & Online Spec Sheets - Datasheet Archive

31

Communication & Control Cable, Multi-Conductor Electronics

Multi-Conductor, Foil Shield AWMStyle2464,CSATypeAWMI/IIA/B,NEC/CECTypeCMG(CSAC/US)

Product Construction: Conductor: •24AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedPVC •Colorcode:Seechartsbelow

Shield: •100%Flexfoil® aluminum/polyester

with25%overlap,foilfacingout •Strandedtinnedcopperdrainwire

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+105˚C

Applications: •Computerinterconnections •Datatransmission •Controlcircuits •Industrialequipmentcontrol •SuitableforEIARS-232applications •Suggestedvoltagerating:300or600

volts

Features: •Superiorshieldingeffectiveness •25%shieldoverlapprovidesexcellent

shielding efficiency •Goodflexibility

Compliances: •AWMStyle2464(ULorCSA:80˚C,

300V) •CSATypeAWM(105˚C,600V) •CSACertifiedCMGtoharmonized

standard UL444 and CSA 22.2 No. 214 •NEC/CECTypeCMG(CSA:105˚C,300V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetCSA70,000BTU

VerticalTrayFlameTest •PassesCSAFT4VerticalFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OF

COND.AWGSIZE

COND.STRAND

NOMINAL INSULATION THICKNESS

NOMINAL JACKET

THICKNESSNOMINAL

O.D.

NOMINAL DCR Ω/kft @20˚C

NOMINAL CAP.*pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

AWM STYLE 2464, CSA TYPE AWM, CSA C/US TYPE CMGC4216A 2 24 7/32 0.010 0.25 0.032 0.81 0.157 3.99 26.0 18.0 40.0 72.0

C4217A 3 24 7/32 0.010 0.25 0.032 0.81 0.164 4.17 26.0 18.0 36.0 66.0

C4218A 4 24 7/32 0.010 0.25 0.032 0.81 0.175 4.45 26.0 18.0 36.0 66.0

C4219A 5 24 7/32 0.010 0.25 0.032 0.81 0.188 4.78 26.0 16.0 36.0 66.0

C4220A 6 24 7/32 0.010 0.25 0.032 0.81 0.201 5.11 26.0 16.0 34.0 61.0

C4221A 7 24 7/32 0.010 0.25 0.032 0.81 0.201 5.11 26.0 16.0 34.0 61.0

C4222A 8 24 7/32 0.010 0.25 0.032 0.81 0.215 5.46 26.0 16.0 34.0 61.0

C4223A 9 24 7/32 0.010 0.25 0.032 0.81 0.228 5.79 26.0 16.0 34.0 61.0

C4224A 10 24 7/32 0.010 0.25 0.032 0.81 0.245 6.22 26.0 14.0 34.0 61.0ColorCodeChart#1

C4225A 15 24 7/32 0.010 0.25 0.032 0.81 0.276 7.01 26.0 14.0 34.0 61.0

C4226A 20 24 7/32 0.010 0.25 0.032 0.81 0.303 7.70 26.0 14.0 34.0 61.0

C4227A 25 24 7/32 0.010 0.25 0.032 0.81 0.333 8.46 26.0 12.0 34.0 61.0

C4228A 30 24 7/32 0.010 0.25 0.032 0.81 0.351 8.92 26.0 12.0 34.0 61.0

C4229A 40 24 7/32 0.010 0.25 0.032 0.81 0.391 9.93 26.0 12.0 34.0 61.0

C4230A 50 24 7/32 0.010 0.25 0.032 0.81 0.439 11.15 26.0 10.0 34.0 61.0

ColorCodeChart#2*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code Chart 1 – For cables up to and including 10 conductorsNO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 6 Blue2 White 7 Orange3 Red 8 Yellow4 Green 9 Violet5 Brown 10 Gray

Color Code Chart 2 Per ICEA – For cables of 15 to 50 conductorsNO. OFCOND. COLOR

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 18 Orange/Red 35 White/Red/Orange2 White 19 Blue/Red 36 Orange/White/Blue3 Red 20 Red/Green 37 White/Red/Blue4 Green 21 Orange/Green 38 Black/White/Green5 Orange 22 Black/White/Red 39 White/Black/Green6 Blue 23 White/Black/Red 40 Red/White/Green7 White/Black 24 Red/Black/White 41 Green/White/Blue8 Red/Black 25 Green/Black/White 42 Orange/Red/Green9 Green/Black 26 Orange/Black/White 43 Blue/Red/Green10 Orange/Black 27 Blue/Black/White 44 Black/White/Blue11 Blue/Black 28 Black/Red/Green 45 White/Black/Blue12 Black/White 29 White/Red/Green 46 Red/White/Blue13 Red/White 30 Red/Black/Green 47 Green/Orange/Red14 Green/White 31 Green/Black/Orange 48 Orange/Red/Blue15 Blue/White 32 Orange/Black/Green 49 Blue/Red/Orange16 Black/Red 33 Blue/White/Orange 50 Black/Orange/Red17 White/Red 34 Black/White/Orange

Page 43: Cross-Reference & Online Spec Sheets - Datasheet Archive

32

Electronics Communication & Control Cable, Multi-Conductor

Power-Limited Tray Cable, Foil Shield NEC Type PLTC

Product Construction: Conductor: •22thru12AWGfullyannealedstranded

tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedPVC •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester,

25%overlapfoilfacingout •Strandedtinnedcopperdrainwire

Jacket: •PVC,gray •Temperaturerange:-20°Cto+105˚C

Applications: •Cabletrayinstallations •Powerlimitedcircuits •Intercomsystems •Businessmachines •Cashregisters •Industrialcontrolsystems •Petrochemicalrefineries •Suggestedvoltagerating:300volts •Burglaralarms

Features: •Sunlight-resistantPVCjacket •Goodweatherresistance •ULtraycablerated

Compliances: •NECArticle725Power-LimitedTray

Cable(UL:105°C,300V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C0450A 2 22 7/30 0.013 0.33 0.037 0.94 0.191 4.85 43.0 77.5

C0451A 3 22 7/30 0.013 0.33 0.037 0.94 0.199 5.05 39.5 71.0

C0452A 2 20 7/28 0.013 0.33 0.037 0.94 0.207 5.26 50.0 89.5

C0453A 3 20 7/28 0.013 0.33 0.037 0.94 0.217 5.51 45.0 81.0

C0454A 2 18 16/30 0.015 0.38 0.037 0.94 0.227 5.77 51.5 92.5

C0455A 3 18 16/30 0.015 0.38 0.037 0.94 0.238 6.04 46.5 83.5

C0456A 2 16 19/.0117 0.013 0.33 0.037 0.94 0.243 6.17 64.0 115.5

C0457A 3 16 19/.0117 0.013 0.33 0.037 0.94 0.255 6.48 56.5 102.0

C0458A 2 14 19/.0147 0.013 0.33 0.042 1.07 0.288 7.32 72.5 131.0

C0459A 3 14 19/.0147 0.015 0.33 0.042 1.07 0.298 7.57 60.0 108.0

C0460A 2 12 19/.0185 0.013 0.33 0.042 1.07 0.315 8.00 80.5 145.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFCOND. COLOR

1 Black

2 Red

3 White

Page 44: Cross-Reference & Online Spec Sheets - Datasheet Archive

33

Communication & Control Cable, Multi-Conductor Electronics

Multi-Conductor, Spiral Shield UL 2095, NEC Type CL2 and CM (UL) c(UL), CSA CMG

Product Construction: Conductor: •22thru16AWGfullyannealedstranded

tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedPVC •Colorcode:Seechartsbelow

Shield: •85%spiraltinnedcopper

Jacket: •PVC,gray •Temperaturerange:-20°Cto+80°C

Applications: •ElectroniccircuitswhereRFshielding

is required •Radiotransmitters •Soundsystems •Recordingstudios •Suggestedvoltagerating:300volts

Features: •Spiralshieldallowseaseof“pigtail

soldering” •Maximumflexibility

Compliances: •NECArticle800TypeCM(UL:75°C) •ULStyle2095(UL:80°C,300V) •CSACMG(CSA:60°C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest •NECArticle725TypeCL2(UL:75°C)

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Color Code Chart 1NO. OFCOND. COLOR

1 Black

2 Red

3 White

4 Green

5 Yellow

6 Blue

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

UL STYLE 2095, CM (UL) c(UL), CSA CMG, 300V

C2882A 2 22 7/30 0.015 0.38 0.032 0.81 0.197 5.00 40.0 72.0

C2888A 2 20 7/28 0.016 0.41 0.032 0.81 0.215 5.46 44.0 80.2

ColorCodeChart#1

CL2/CM (UL) c(UL), CSA CMG, 300V

C1335A 3 22 7/30 0.015 0.38 0.032 0.81 0.206 5.23 37.0 67.0

C1337A 4 22 7/30 0.015 0.38 0.032 0.81 0.222 5.64 37.0 67.0

C1341A 6 22 7/30 0.015 0.38 0.032 0.81 0.257 6.53 34.5 62.0

C2768A 3 18 7/26 0.020 0.51 0.032 0.81 0.266 6.76 41.0 74.0

ColorCodeChart#1

CM (UL) c(UL), CSA CMG, 300V

C2892A 2 18 16/30 0.016 0.41 0.032 0.81 0.252 6.40 49.5 89.0

C2895A 2 16 19/.0117 0.016 0.41 0.032 0.81 0.265 6.73 58.0 104.0

ColorCodeChart#2*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code Chart 2CATALOGNUMBER CONDUCTOR COLOR

C2892A 12

WhiteRed

C2895A 12

WhiteBlack

Page 45: Cross-Reference & Online Spec Sheets - Datasheet Archive

34

Electronics Communication & Control Cable, Multi-Conductor

Multi-Conductor, Braid Shield NEC Type CL2 and CM(UL) c(UL), CSA CMG

Product Construction: Conductor: •22AWGfullyannealedsolidorstranded

tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedPVC •Colorcode:Seechartbelow

Shield: •88%tinnedcopperbraid •Strandedorsolidtinnedcopperdrain

wire

Jacket: •PVC,black •Temperaturerange:-20°Cto+75°C

Applications: •ElectroniccircuitswhereRFshielding

is required •Radiotransmitters •Soundsystems •Recordingstudios •Goodflexibility •Excellentshieldingfornoisereduction •Suggestedvoltagerating:300volts

Compliances: •NECArticle800TypeCM(UL:75°C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •NECArticle725TypeCL2(UL:75°C)

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C2676A 2 22 Solid 0.015 0.38 0.032 0.81 0.209 5.31 38.6 69.4

C2677A 2 22 7/30 0.015 0.38 0.032 0.81 0.211 5.36 39.3 70.7

*A – Capacitance between conductors* *B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFCOND. COLOR

1 Black

2 Red

Page 46: Cross-Reference & Online Spec Sheets - Datasheet Archive

35

Communication & Control Cable, Multi-Conductor Electronics

Multi-Conductor, Braid Shield UL2092,2093,2094,NECTypeCM(UL)c(UL)CMH

Product Construction: Conductor: •20AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-coded

polyethylene •Colorcode:Seechartbelow

Shield: •80%tinnedcopperbraid •Mylarwrapunderbraid

Jacket: •PVC,gray •Temperaturerange:-20°Cto+75°C

Applications: •ElectroniccircuitswhereRFshielding

is required •Videointerconnect •Broadcastandstudio •Soundsystems •Suggestedvoltagerating:300volts

Features: •Lowcapacitance •Lightweight •Excellentshieldingfornoisereduction

Compliances: •NECArticle800TypeCM/CMH

(UL:75°C) •AWMstyle2092(UL:60˚C,300V) •AWMstyle2093(UL:60˚C,300V) •AWMstyle2094(UL:60˚C,300V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetULVW-1VerticalWire

Flame Test

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

AWM STYLE 2092, CM (UL) c(UL) CMH, 300V

C1642A 2 20 26/34 0.016 0.38 0.029 0.74 0.226 5.74 24.0 43.0

AWM STYLE 2093, CM (UL) c(UL) CMH, 300V

C1643A 3 20 26/34 0.016 0.38 0.029 0.74 0.236 5.99 22.0 40.0

AWM STYLE 2094, CM (UL) c(UL) CMH 300V

C1644A 4 20 26/34 0.016 0.38 0.029 0.74 0.255 6.48 22.0 39.0

C1645A 5 20 26/34 0.016 0.38 0.029 0.74 0.274 6.96 22.0 39.0

C1646A 6 20 26/34 0.016 0.38 0.029 0.74 0.290 7.37 20.0 36.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFCOND. COLOR

1 Black

2 White

3 Red

4 Green

5 Yellow

6 Blue

Page 47: Cross-Reference & Online Spec Sheets - Datasheet Archive

36

Electronics Communication & Control Cable, Multi-Conductor

Multi-Conductor, Braid Shield UL 2095, NEC Type CM (UL) c(UL)

Product Construction: Conductor: •22thru16AWGfullyannealedstranded

tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedPVC •Colorcode:Seechartbelow

Shield: •75%tinnedcopperbraid

Jacket: •PVC,gray •Temperaturerange:-20°Cto+80°C

Applications: •ElectroniccircuitswhereRFshielding

is required •Radiotransmitters •Soundsystems •Recordingstudios •Providesgoodflexibility •Excellentshieldingfornoisereduction •Suggestedvoltagerating:300volts

Compliances: •NECArticle800TypeCM(UL:75°C) •ULStyle2095(UL:80°C,300V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •CSACMG(CSA:60°C) •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C2679A 2 22 7/30 0.015 0.38 0.032 0.81 0.212 5.38 40.0 72.0

C2678A 3 22 7/30 0.015 0.38 0.032 0.81 0.221 5.61 37.0 67.0

C2680A 4 22 7/30 0.015 0.38 0.032 0.81 0.237 6.02 37.0 67.0

C2681A 2 20 7/28 0.016 0.41 0.032 0.81 0.230 5.84 44.0 80.0

C1332A 3 20 7/28 0.016 0.41 0.032 0.81 0.240 6.10 40.0 72.0

C2683A 4 20 7/28 0.016 0.41 0.032 0.81 0.259 6.58 40.0 73.0

C2686A 2 18 16/30 0.016 0.41 0.032 0.81 0.252 6.40 49.0 89.0

C2687A 3 18 16/30 0.016 0.41 0.032 0.81 0.264 6.71 45.0 80.5

C2688A 4 18 16/30 0.016 0.41 0.032 0.81 0.286 7.26 45.0 80.5

C2689A 2 16 19/29 0.020 0.51 0.030 0.76 0.280 7.11 51.0 91.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFCOND. COLOR

1 Black

2 Red

3 White

4 Green

Page 48: Cross-Reference & Online Spec Sheets - Datasheet Archive

37

Communication & Control Cable, Multi-Conductor Electronics

Multi-Conductor, Braid Shield MIL-W-16878TypeB

Product Construction: Conductor: •28AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedPVCper

MIL-W-16878TypeB •Colorcode:Seechartbelow

Shield: •90%tinnedcopperbraid

Jacket: •PVC,gray •Temperaturerange:-20°Cto+90°C

Applications: •ElectroniccircuitswhereRFshielding

is required •Remotecontrolforstudioequipment •Soundsystems •Providesgoodflexibility •Excellentshieldingfornoisereduction •Suggestedvoltagerating:600volts •NonQPL

Compliances: •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C6500A 2 28 7/36 0.010 0.28 0.016 0.41 0.130 3.30 34.0 61.0

C6501A 3 28 7/36 0.010 0.28 0.016 0.41 0.135 3.30 32.5 58.5

C6502A 4 28 7/36 0.010 0.28 0.016 0.41 0.145 3.68 32.5 58.5

C6503A 6 28 7/36 0.010 0.28 0.019 0.48 0.172 4.37 30.5 55.0

C6504A 8 28 7/36 0.010 0.28 0.021 0.53 0.187 4.75 30.5 55.0

C6505A 10 28 7/36 0.010 0.28 0.021 0.53 0.212 5.38 30.5 55.0

C6506A 12 28 7/36 0.010 0.28 0.021 0.53 0.217 5.51 30.5 55.0

C6507A 15 28 7/36 0.010 0.28 0.021 0.53 0.237 6.01 30.5 55.0

C6508A 20 28 7/36 0.010 0.28 0.021 0.53 0.259 6.58 30.5 55.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFCOND. COLOR

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 8 Red/Black 15 Blue/White

2 White 9 Green/Black 16 Black/Red

3 Red 10 Orange/Black 17 White/Red

4 Green 11 Blue/Black 18 Orange/Red

5 Orange 12 Black/White 19 Blue/Red

6 Blue 13 Red/White 20 Red/Green

7 White/Black 14 Green/White

Page 49: Cross-Reference & Online Spec Sheets - Datasheet Archive

38

Electronics Communication & Control Cable, Multi-Conductor

Multi-Conductor, Foil/Braid Shield UL 2094, NEC Type CL2

Product Construction: Conductor: •20AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-coded

polyethylene •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester,

25%overlap,foilfacingout •80%tinnedcopperbraid

Jacket: •PVC,gray •Temperaturerange:-20°Cto+75°C

Applications: •ElectroniccircuitswhereRFshielding

is required •Videointerconnect •Broadcastandstudio •Soundsystems •Suggestedvoltagerating:300volts

Features: •Lowcapacitance •Lightweight •Excellentshieldingfornoisereduction

Compliances: •NECArticle725TypeCL2(UL:75°C) •ULStyle2094(UL:60°C,300V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C1648A 8 20 26/34 0.016 0.38 0.029 0.74 0.316 8.03 20.0 36.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code Chart

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 5 Yellow

2 White 6 Blue

3 Red 7 Brown

4 Green 8 Orange

Page 50: Cross-Reference & Online Spec Sheets - Datasheet Archive

39

Communication & Control Cable, Multi-Conductor Electronics

Multi-Conductor, Foil & TC Braid Shield NEC Type CMP (UL) c(UL)

Product Construction: Conductor: •Fullyannealedstrandedtinnedcopper

per ASTM B-33

Insulation: •Premium-grade,coIor-codedFEP •Colorcode:Seechartbelow

Separator: •Polyestertapewith25%overlap

Shield: •100%Flexfoil® aluminum/polyester foil

with25%overlap •Tinnedcopperbraid,90%coverage

Jacket: •FEP,redorasrequested •Temperaturerange:-40°Cto+200°C

Applications: •Computersystems •Remotecontrolcircuits •Processcontrolandinstrumentation •Audiocontrols •Suggestedvoltagerating:300volts

Compliances: •NECArticle800 •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Fire-retardant,low-smokejacket

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

16 AWG CONDUCTORS

C8108 6 16 19/29 0.007 0.18 0.014 0.36 0.270 6.86 33.0 61.0

C8119 3 16 19/29 0.007 0.18 0.014 0.36 0.209 5.31 35.0 63.0

C8111 2 16 19/29 0.007 0.18 0.014 0.36 0.198 5.03 35.0 63.0

18 AWG CONDUCTORS

C8120 6 18 19/30 0.007 0.18 0.014 0.36 0.242 6.15 33.0 61.0

C8110 4 18 19/30 0.007 0.18 0.014 0.36 0.206 5.23 35.0 63.0

C8107 3 18 19/30 0.007 0.18 0.014 0.36 0.190 4.83 35.0 63.0

24 AWG CONDUCTORS

C8115 3 24 7/32 0.006 0.15 0.014 0.36 0.133 3.38 25.0 45.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFCOND. COLOR

1 Black

2 White

3 Red

4 Green

5 Orange

6 Blue

Page 51: Cross-Reference & Online Spec Sheets - Datasheet Archive

40

Electronics Communication & Control Cable, Multi-Conductor

Multi-Conductor, Rubber, Braid Shield

Product Construction: Conductor: •20AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedrubber •Colorcode:Seechartbelow

Shield: •80%tinnedcopperbraid

Jacket: •Rubber,black •Temperaturerange:-20°Cto+60°C

Applications: •Controlcircuits •Broadcastandstudioapplications •Audiointerconnects •Suggestedvoltagerating:300volts

Features: •Impact-andabrasion-resistant •Strandedconductorsforsuperior

flexibility

Compliances: •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

INCHES mm INCHES mm INCHES mm

C1302 2 20 26/34 0.020 0.51 0.035 0.89 0.270 6.86

C1304 3 20 26/34 0.020 0.51 0.035 0.89 0.285 7.24

C1305 4 20 26/34 0.020 0.51 0.035 0.89 0.300 7.62

C1308 5 20 26/34 0.020 0.51 0.035 0.89 0.330 8.38

C1310 6 20 26/34 0.020 0.51 0.035 0.89 0.340 8.64

C1312 7 20 26/34 0.020 0.51 0.035 0.89 0.355 9.02

C1313 8 20 26/34 0.020 0.51 0.035 0.89 0.385 9.78

Color Code Chart

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 5 Blue

2 White 6 Brown

3 Red 7 Yellow

4 Green 8 Orange

Page 52: Cross-Reference & Online Spec Sheets - Datasheet Archive

41

Communication & Control Cable, Multi-Conductor Electronics

Multi-Conductor, Carolprene®, Braid Shield

Product Construction: Conductor: •18thru14AWGfullyannealedstranded

tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedrubber •Colorcode:Seechartbelow

Shield: •80%tinnedcopperbraid

Jacket: •Carolprene®, black •Temperaturerange:-20°Cto+60°C

Applications: •Controlcircuits •Broadcastandstudioapplications •Audiointerconnects •Suggestedvoltagerating:300volts

Features: •Impact-andabrasion-resistant •Strandedconductorsforsuperior

flexibility •DesignedtomeetULVW-1VerticalWire

Flame Test

Compliance: •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

INCHES mm INCHES mm INCHES mm

C1202 2 18 41/34 0.020 0.51 0.035 0.89 0.295 7.49

C1203 3 18 41/34 0.020 0.51 0.035 0.89 0.305 7.75

C1204 4 18 41/34 0.020 0.51 0.035 0.89 0.330 8.38

C1206 6 18 41/34 0.020 0.51 0.035 0.89 0.370 9.39

C1208 8 18 41/34 0.020 0.51 0.035 0.89 0.420 10.67

C1210 10 18 41/34 0.020 0.51 0.035 0.89 0.425 10.80

C1212 12 18 41/34 0.020 0.51 0.065 1.65 0.555 14.10

C1602 2 16 65/34 0.025 0.64 0.035 0.89 0.335 8.51

C1603 3 16 65/34 0.025 0.64 0.035 0.89 0.355 9.02

C1604 4 16 65/34 0.025 0.64 0.035 0.89 0.385 9.78

C1606 6 16 65/34 0.025 0.64 0.040 1.02 0.445 11.30

C1608 8 16 65/34 0.025 0.64 0.040 1.02 0.510 12.95

C1612 2 14 41/30 0.030 0.76 0.040 1.02 0.395 10.03

C1614 4 14 41/30 0.030 0.76 0.040 1.02 0.455 11.56

Color Code Chart

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 7 Yellow

2 White 8 Orange

3 Red 9 Gray

4 Green 10 Violet

5 Blue 11 White/Black

6 Brown 12 White/Red

Page 53: Cross-Reference & Online Spec Sheets - Datasheet Archive

42

Electronics

Index Page

Multi-Paired, Unshielded 43-45

Multi-Paired, Foil Shield 46-52

Multi-Paired, Foil Shield (CSA) 53-54

Multi-Paired, Foil Shield, Mid-Cap 55

Multi-Paired, Foil Shield, Lo-Cap® 56

Multi-Paired, Overall Foil & TC Braid Shield, Lo-Cap® 57

Multi-Paired, Individually Shielded 58

Multi-Paired, Individually Shielded (CSA) 59

Multi-Paired, Individually Shielded, Overall Shield 60

Multi-Paired, Individually Foil Shielded 61-64

Power-Limited Tray Cable, Individually Shielded 65

Power-Limited Tray Cable, Foil Shield or Foil/Braid Shield 66

In many electronic applications, two wires are required to complete circuits; these are often referred to as “balanced arrays” or “twisted pair” constructions.

Paired cable designs find frequent application in circuits requiring circuit-to-circuit isolation from noise, minimization of capacitance imbalances and a reduction of EMI interference currents.

Circuit separation is further enhanced in those designs employing individual circuit shields in concert with an overall shield. These shielding systems are available from General Cable in myriad combinations to suit the unique needs of the circuit designer.

As with the multi-conductor designs, a wide array of insulating and jacketing materials are available to meet specific electronic applications.

General Cable’s Carol® Brand communication cable products are manufactured to meet the latest UL, CSA and NEC requirements and approvals.

Communication & Control Cable, Multi-Paired 3

Page 54: Cross-Reference & Online Spec Sheets - Datasheet Archive

43

Communication & Control Cable, Multi-Paired Electronics

Multi-Paired, Unshielded UL 2464, NEC Type CM (UL) c(UL), CSA CMG

Product Construction: Conductor: •22AWGfullyannealedsolidorstranded

tinned copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-codedS-RPVC •Colorcode:Seechartbelow

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+80˚C

Applications: •Computers •Industrialequipment •Datatransmission •Controlcircuits •SuitableforEIARS-232applications •Suggestedvoltagerating:300volts

Compliances: •NECArticle800TypeCM(UL:75˚C) •ULStyle2464(UL:80˚C,300V) •CSACMG(CSA:60˚C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOGNUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS

NOM. JACKETTHICKNESS NOMINAL O.D.

NOM. C-C

CAP.* pF/ftINCHES mm INCHES mm INCHES mm

C4008A 1 22 Solid 0.010 0.25 0.032 0.81 0.156 3.94 24.5

C4010A 2 22 Solid 0.010 0.25 0.032 0.81 0.218 5.54 24.5

C4014A 3 22 Solid 0.010 0.25 0.032 0.81 0.229 5.82 24.5

C4015A 4 22 Solid 0.010 0.25 0.032 0.81 0.249 6.32 24.5

C4017A 6 22 Solid 0.012 0.30 0.032 0.81 0.293 7.44 24.5

C6010A 2 22 7/30 0.010 0.25 0.032 0.81 0.228 5.79 24.5

C6014A 3 22 7/30 0.010 0.25 0.032 0.81 0.240 6.10 24.5

C6015A 4 22 7/30 0.010 0.25 0.032 0.81 0.262 6.65 24.5

C6017A 6 22 7/30 0.010 0.25 0.032 0.81 0.300 7.62 24.5

C6019A 9 22 7/30 0.010 0.25 0.032 0.81 0.366 9.30 24.5

C6023A 12 22 7/30 0.010 0.25 0.032 0.81 0.410 10.40 24.5

C6026A 15 22 7/30 0.010 0.25 0.032 0.81 0.456 11.58 24.5

* Capacitance between conductors

Color Code ChartNO. OFPAIRS COLOR

NO. OFPAIRS COLOR

1 BlackpairedwithRed 9 RedpairedwithGreen

2 BlackpairedwithWhite 10 RedpairedwithBlue

3 Black paired with Green 11 RedpairedwithYellow

4 Black paired with Blue 12 RedpairedwithBrown

5 BlackpairedwithYellow 13 RedpairedwithOrange

6 Black paired with Brown 14 GreenpairedwithWhite

7 Black paired with Orange 15 Green paired with Blue

8 RedpairedwithWhite

Page 55: Cross-Reference & Online Spec Sheets - Datasheet Archive

44

Electronics Communication & Control Cable, Multi-Paired

Multi-Paired, Unshielded UL 2464, NEC Type CM (UL) c(UL), CSA CMG

Product Construction: Conductor: •18AWGfullyannealedstrandedtinned

copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-codedS-RPVC •Colorcode:Seechartbelow

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+80˚C

Applications: •Computers •Industrialequipment •Datatransmission •Controlcircuits •SuitableforEIARS-232applications •Suggestedvoltagerating:300volts

Compliances: •NECArticle800TypeCM(UL:75˚C) •ULStyle2464(UL:80˚C,300V) •CSACMG(CSA:60˚C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOGNUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS

NOM. JACKETTHICKNESS NOMINAL O.D.

NOM. C-C

CAP.* pF/ftINCHES mm INCHES mm INCHES mm

C6101A 1 18 16/30 0.013 0.33 0.032 0.81 0.206 5.23 26.3

C6118A 2 18 16/30 0.013 0.33 0.032 0.81 0.320 8.13 26.3

C6103A 3 18 16/30 0.013 0.33 0.032 0.81 0.338 8.59 26.3

C6119A 4 18 16/30 0.013 0.33 0.032 0.81 0.372 9.45 26.3

C6120A 5 18 16/30 0.013 0.33 0.032 0.81 0.408 10.36 26.3

C6106A 6 18 16/30 0.013 0.33 0.032 0.81 0.445 11.30 26.3

C6121A 8 18 16/30 0.013 0.33 0.032 0.81 0.484 12.29 26.3

C6109A 9 18 16/30 0.013 0.33 0.032 0.81 0.522 13.26 26.3

C6111A 15 18 16/30 0.013 0.33 0.032 0.81 0.659 16.74 26.3

* Capacitance between conductors

Color Code ChartNO. OFPAIRS COLOR

NO. OFPAIRS COLOR

1 BlackpairedwithRed 9 RedpairedwithGreen

2 BlackpairedwithWhite 10 RedpairedwithBlue

3 Black paired with Green 11 RedpairedwithYellow

4 Black paired with Blue 12 RedpairedwithBrown

5 BlackpairedwithYellow 13 RedpairedwithOrange

6 Black paired with Brown 14 GreenpairedwithWhite

7 Black paired with Orange 15 Green paired with Blue

8 RedpairedwithWhite

Page 56: Cross-Reference & Online Spec Sheets - Datasheet Archive

45

Communication & Control Cable, Multi-Paired Electronics

Color Code ChartNO. OFPAIRS COLOR

1 BlackandRed

Product Construction: Conductor: •18AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedFEP •Colorcode:Seechartbelow

Jacket: C8116 •FEP,redorasrequested •Temperaturerange:-40°Cto+200°C

C8122 •Flexguard®PVC,natural •Temperaturerange:-20°Cto+75°C

Applications: •Audiosystems •Remotecontrolcircuits •Processcontrolandinstrumentation •Suggestedvoltagerating:300volts

Compliances: •NECArticle800 •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Fire-retardant,low-smokejacket

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Multi-Paired, Unshielded NEC Type CMP (UL) c(UL)

CATALOGNUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS

NOM. JACKETTHICKNESS NOMINAL O.D. NOM. C-C

CAP.*pF/ftINCHES mm INCHES mm INCHES mm

C8116 1 18 19/30 0.007 0.18 0.009 0.23 0.142 3.61 20.0

C8122 1 18 19/30 0.007 0.18 0.015 0.38 0.154 3.91 20.0

*Capacitance between conductors

Page 57: Cross-Reference & Online Spec Sheets - Datasheet Archive

46

Electronics Communication & Control Cable, Multi-Paired

Multi-Paired, Foil Shield NEC Type CM (UL) c(UL), CSA CMG

Product Construction: Conductor: •22AWGfullyannealedsolidorstranded

tinned copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-codedS-RPVC •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester,

25%overlap,foilfacingout •Strandedtinnedcopperdrainwire

Jacket: •PVC,gray •Temperaturerange:-20°Cto+75°C

Applications: •Audiosystems •Communicationcircuits •Instrumentationandcontroluse •Suggestedvoltagerating:300volts

Compliances: •NECArticle800TypeCM

(UL:75°C,300V) •CSACMG(CSA:60°C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOMINAL CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C7104A† 1 22 7/.0096 0.013 0.33 0.035 0.89 0.185 4.70 35.0 62.0

C1670A 2 22 Solid 0.010 0.25 0.032 0.81 0.218 5.54 32.0 57.0

C1676A 4 22 Solid 0.010 0.25 0.032 0.81 0.249 6.32 28.0 50.0

C1671A 6 22 Solid 0.010 0.25 0.032 0.81 0.292 7.42 25.0 45.0

C1672A 9 22 Solid 0.010 0.25 0.032 0.81 0.338 8.59 25.0 45.0

C1673A 15 22 Solid 0.010 0.25 0.032 0.81 0.419 10.64 25.0 45.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield †AlsoULStyle2464(UL:80°C,300V)

Color Code ChartNO. OFPAIRS COLOR

NO. OFPAIRS COLOR

1 BlackpairedwithRed 9 RedpairedwithGreen

2 BlackpairedwithWhite 10 RedpairedwithBlue

3 Black paired with Green 11 RedpairedwithYellow

4 Black paired with Blue 12 RedpairedwithBrown

5 BlackpairedwithYellow 13 RedpairedwithOrange

6 Black paired with Brown 14 GreenpairedwithWhite

7 Black paired with Orange 15 Green paired with Blue

8 RedpairedwithWhite

Page 58: Cross-Reference & Online Spec Sheets - Datasheet Archive

47

Communication & Control Cable, Multi-Paired Electronics

Multi-Paired, Foil Shield UL 2095, NEC Type CM (UL) c(UL)

Product Construction: Conductor: •22AWGfullyannealedsolidtinned

copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-codedS-RPVC •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester,

25%overlap,foilfacingout •Strandedtinnedcopperdrainwire

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+80˚C

Applications: •Intercomsystems •Soundsystems •Electronicinstrumentationcontrol

systems •Suggestedvoltagerating:300volts

Compliances: •NECArticle800TypeCM

(UL:75°C,300V) •ULStyle2095(UL:80˚C,300V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOMINAL CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C6451A 51 22 Solid 0.010 0.25 0.050 1.27 0.715 18.16 25.0 45.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFPAIRS COLOR

NO. OFPAIRS COLOR

NO. OFPAIRS COLOR

1 BluepairedwithWhite2 OrangepairedwithWhite3 GreenpairedwithWhite4 BrownpairedwithWhite5 GraypairedwithWhite

6 Blue/WhitestripedpairedwithWhite

7 Blue/Orange stripedpairedwithWhite

8 Blue/Green stripedpairedwithWhite

9 Blue/Brown stripedpairedwithWhite

10 Blue/Gray stripedpairedwithWhite

11 Orange/WhitestripedpairedwithWhite

12 Orange/Green stripedpairedwithWhite

13 Orange/Brown stripedpairedwithWhite

14 Orange/Gray stripedpairedwithWhite

15 Green/WhitestripedpairedwithWhite

16 Green/Brown stripedpairedwithWhite

17 Green/Gray stripedpairedwithWhite

18 Brown/WhitestripedpairedwithWhite

19 Brown/Gray stripedpairedwithWhite

20 Gray/WhitestripedpairedwithWhite

21 BluepairedwithRed22 OrangepairedwithRed23 GreenpairedwithRed24 BrownpairedwithRed25 GraypairedwithRed

26 Blue/WhitestripedpairedwithRed

27 Blue/Orange stripedpairedwithRed

28 Blue/Green stripedpairedwithRed

29 Blue/Brown stripedpairedwithRed

30 Blue/Gray stripedpairedwithRed

31 Orange/WhitestripedpairedwithRed

32 Orange/Green stripedpairedwithRed

33 Orange/Brown stripedpairedwithRed

34 Orange/Gray stripedpairedwithRed

35 Green/WhitestripedpairedwithRed

36 Green/Brown stripedpairedwithRed

37 Green/Gray stripedpairedwithRed

38 Brown/WhitestripedpairedwithRed

39 Brown/Gray stripedpairedwithRed

40 Gray/WhitestripedpairedwithRed

41 Blue paired with Black42 Orange paired with Black43 Green paired with Black44 Brown paired with Black45 Gray paired with Black

46 Blue/Whitestripedpaired with Black

47 Blue/Orange stripedpaired with Black

48 Blue/Green stripedpaired with Black

49 Blue/Brown stripedpaired with Black

50 Blue/Gray stripedpaired with Black

51 Orange/Whitestripedpaired with Black

Page 59: Cross-Reference & Online Spec Sheets - Datasheet Archive

48

Electronics Communication & Control Cable, Multi-Paired

Multi-Paired, Foil Shield NEC Type CMP (UL) c(UL)

Product Construction: Conductor: •22and24AWGfullyannealedstranded

tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-coded

fluoropolymer •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester foil

with25%overlap,minimum •Strandedtinnedcopperdrainwire

Jacket: •Fluoropolymer,natural •Temperaturerange:-40°Cto+150°C •Sequentialfootagemarkedtofacilitate

installation •Includesripcord

Applications: •EIARS-232circuits •Remotecontrolcircuits •Processcontrolandinstrumentation •Power-limitedcontrolcircuits •Suggestedvoltagerating:300volts

Compliances: •NECArticle800(UL:150°C,300V) •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Water-resistantjacket

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

22 AWG CONDUCTORS

C3204 1 22 7/30 0.006 0.15 0.010 0.25 0.117 2.97 31.0 55.8

C3205 2 22 7/30 0.006 0.15 0.010 0.25 0.151 3.84 25.0 45.0

C3206 3 22 7/30 0.006 0.15 0.010 0.25 0.177 4.50 25.0 36.0

C3207 4 22 7/30 0.006 0.15 0.010 0.25 0.200 5.08 20.0 45.0

C3208 6 22 7/30 0.006 0.15 0.010 0.25 0.237 6.02 18.0 32.4

24 AWG CONDUCTORS

C3150 2 24 7/32 0.006 0.15 0.010 0.25 0.130 3.30 22.0 39.6

C3153 3 24 7/32 0.006 0.15 0.010 0.25 0.152 3.86 18.0 32.4

C3151 4 24 7/32 0.006 0.15 0.010 0.25 0.170 4.32 17.0 30.6

C3165 6 24 7/32 0.006 0.15 0.010 0.25 0.200 5.08 17.0 30.6

C3152 12.5 24 7/32 0.006 0.15 0.012 0.30 0.290 7.04 17.0 30.6

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFPAIRS COLOR

1 Black&Yellow

2 Red&Violet

3 DarkBlue&Brown

4 Orange&DarkGreen

5 Pink & Gray

6 Tan&White

7 Light Blue & Light Green

8 Red/White&White/Red

9 Orange/White&White/Orange

10 Yellow/White&White/Yellow

11 Gray/White&White/Gray

12 Blue/White&White/Blue

1C DarkGreen/Yellow

Page 60: Cross-Reference & Online Spec Sheets - Datasheet Archive

49

Communication & Control Cable, Multi-Paired Electronics

Multi-Paired, Foil Shield NEC Type CMP (UL) c(UL)

Product Construction: Conductor: •22and18AWGfullyannealedstranded

tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedFEP •Colorcode:Seechartbelow

Separator: •Polyestertapewith25%overlap

Shield: •100%Flexfoil® aluminum/polyester foil

with25%overlap,minimum •Strandedtinnedcopperdrainwire

Jacket: •FEP,redorasrequested •PVDF,redorasrequested C8101, C8109 •Temperaturerange:-40°Cto+200°C C8104, C8103 •Temperaturerange:-40°Cto+150°C

Applications: •Computersystems •Remotecontrolcircuits •Processcontrolandinstrumentation •Suggestedvoltagerating:300volts

Compliances: •NECArticle800 •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Fire-retardant,low-smokejacket

Packaging: •PleasecontactCustomerServicefor

packaging and color options •1000'(305m)reels

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C8101** 1 18 19/30 0.007 0.18 0.016 0.41 0.165 4.19 51.0 95.0

C8104 1 18 19/30 0.007 0.18 0.016 0.41 0.165 4.19 51.0 95.0

C8103 1 22 7/30 0.006 0.15 0.014 0.36 0.120 3.05 35.0 65.0

C8109** 1 22 7/30 0.006 0.15 0.016 0.41 0.122 3.10 35.0 65.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield** FEP jacket

Color Code ChartNO. OFPAIRS COLOR

1 BlackandRed

Page 61: Cross-Reference & Online Spec Sheets - Datasheet Archive

50

Electronics Communication & Control Cable, Multi-Paired

Multi-Paired, Foil Shield NEC Type CMP (UL) c(UL)

Product Construction: Conductor: •24AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedfoamFEP •Colorcode:Seechartbelow

Separator: •Polyestertapewith25%overlap

Shield: •100%Flexfoil® aluminum/polyester foil

with25%overlap,minimum •Strandedtinnedcopperdrainwire

Jacket: •PVDF,grayorasrequested •Temperaturerange:-40°Cto+150°C

Applications: •Computersystems •Remotecontrolcircuits •Processcontrolandinstrumentation •SuitableforRS232,RS422,RS485 •Suggestedvoltagerating:300volts

Compliances: •NECArticle800 •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Fire-retardant,low-smokejacket

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C8118 2 24 7/32 0.014 0.15 0.015 0.38 0.203 5.16 12.0 22.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFPAIRS COLOR

1 White/BluepairedwithBlue/White

2 White/OrangepairedwithOrange/White

Page 62: Cross-Reference & Online Spec Sheets - Datasheet Archive

51

Communication & Control Cable, Multi-Paired Electronics

Color Code ChartNO. OFPAIRS COLOR

1 BlackandRed

C8113NO. OF PAIRS COLOR

1 BlackpairedwithWhite

2 BlackpairedwithRed

3 Black paired with Green

Multi-Paired, Foil Shield NEC Type CMP (UL) c(UL)

Product Construction: Conductor: •24,22and18AWGfullyannealed

stranded tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedFEP •Colorcode:Seechartbelow

Separator: •Polyestertapewith25%overlap

Shield: •100%Flexfoil® aluminum/polyester foil

with25%overlap,minimum •Strandedtinnedcopperdrainwire

Jacket: •Flexguard®PVC,naturalorasrequested •Temperaturerange:-20°Cto+75°C

Applications: •Computersystems •Remotecontrolcircuits •Processcontrolandinstrumentation •Suggestedvoltagerating:300volts

Compliances: •NECArticle800 •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Fire-retardant,low-smokejacket

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C8127 1 24 7/32 0.006 0.15 0.014 0.36 0.108 2.69 30.0 60.0

C8113 3 24 7/32 0.006 0.15 0.014 0.36 0.161 4.09 25.0 45.0

C8126 1 22 7/30 0.006 0.15 0.014 0.36 0.120 3.05 35.0 65.0

C8123 1 18 19/30 0.007 0.18 0.014 0.36 0.160 4.06 51.0 90.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

C8124** 1 22 7/30 0.007 0.18 0.017 0.43 0.128 3.25 32.0 62.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield ** This item does not have a separator and has a shield fusible to the jacket to facilitate removal along with the jacket while stripping.

Page 63: Cross-Reference & Online Spec Sheets - Datasheet Archive

52

Electronics Communication & Control Cable, Multi-Paired

Multi-Paired, Foil Shield NEC Type CMP (UL) c(UL) and/or CL2P

Product Construction: Conductor: •22and18AWGfullyannealedstranded

tinned copper per ASTM B-33 or stranded bare copper per ASTM B-3

Insulation: •Premium-grade,coIor-codedFlexguard®

PVC •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester foil

with25%overlap,minimum •Strandedtinnedcopperdrainwire

Jacket: •Fluoropolymer,natural •Temperaturerange:-20°Cto+75°C •Sequentialfootagemarkedtofacilitate

installation •Includesripcord

Applications: •EIARS-232circuits •Remotecontrolcircuits •Processcontrolandinstrumentation •Power-limitedcontrolcircuits •Suggestedvoltagerating:150volts

Compliances: •NECArticle800(UL:75°C,300V) •NECArticle725(UL:75°C,150V) •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Abrasion-,chemical-andwater-resistant

jacket

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

22 AWG, CL2P, c(UL) 150 VOLTS

C3352 2 22 7/30 TC 0.007 0.180 0.010 0.25 0.157 3.99 37.0 66.0

C3353 3 22 7/30 TC 0.007 0.180 0.010 0.25 0.194 4.42 30.0 53.0

C3354 4 22 7/30 TC 0.007 0.180 0.010 0.25 0.207 4.75 30.0 53.0

C3356 6 22 7/30 TC 0.007 0.180 0.010 0.25 0.246 5.74 27.0 48.0

18 AWG, CL2P/CMP, c(UL) 150 VOLTS

C3362 2 18 7/26 BC 0.008 0.020 0.010 0.25 0.205 5.21 44.0 79.0

C3364 4 18 7/26 BC 0.008 0.020 0.010 0.25 0.277 7.04 33.0 59.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFPAIRS COLOR

1 Black&Yellow

2 Red&Violet

3 DarkBlue&Brown

4 Orange&DarkGreen

5 Pink & Gray

6 Tan&White

Page 64: Cross-Reference & Online Spec Sheets - Datasheet Archive

53

Communication & Control Cable, Multi-Paired Electronics

Multi-Paired, Foil Shield AWMStyle2464,CSATypeAWMI/IIA/B,NEC/CECTypeCMG(CSAC/US)

Product Construction: Conductor: •24AWGfullyannealedstrandedtinned

copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-codedPVC •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester,

25%overlap,foilfacingout •Strandedtinnedcopperdrainwire

Jacket: •PVC,gray •Temperaturerange:-20°Cto+105°C

Applications: •Computers •Industrialequipment •Datatransmission •Controlcircuits •SuitableforEIARS-232applications •Suggestedvoltagerating:300or600

volts

Features: •Excellentelectricalproperties •Superiorshieldingeffectiveness •25%shieldoverlapprovidesexcellent

shielding efficiency •Assistssystemdesignersinmeeting

FCCDocket20780demands •Goodflexibility

Compliances: •AWMStyle2464(CSA:80˚C,300V) •CSATypeAWM(105˚C,600V) •CSACertifiedCMGtoharmonized

standard UL444 and CSA 22.2 No. 214 •NEC/CECTypeCMG(CSA:105˚C,300V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetCSA70,000BTU

VerticalTrayFlameTest •PassesCSAFT4VerticalFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO.OF

PAIRSAWGSIZE

COND.STRAND

NOM.INSULATION THICKNESS

NOM. JACKET

THICKNESS NOMINAL O.D.

NOMINALDCRΩ/KFT COLOR

CODE

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

C4170A 1 24 7/32 0.010 0.25 0.032 0.81 0.157 3.99 26.0 18.0 1 36.4 65.5

C4209A 1 24 7/32 0.010 0.25 0.032 0.81 0.157 3.99 26.0 18.0 Wht/Blk 36.4 65.5

C4191A 1 24 7/32 0.009 0.23 0.030 0.76 0.148 3.78 26.0 16.5 Blk/Red 43.0 78.0

C4171A 2 24 7/32 0.010 0.25 0.032 0.81 0.214 5.44 26.0 18.0 1 31.9 57.3

C4172A 3 24 7/32 0.010 0.25 0.032 0.81 0.225 5.72 26.0 16.5 1 28.6 51.4

C4173A 4 24 7/32 0.010 0.25 0.032 0.81 0.245 6.22 26.0 16.5 1 28.6 51.4

C4174A 5 24 7/32 0.010 0.25 0.032 0.81 0.265 6.73 26.0 16.5 1 28.6 51.4

C4175A 6 24 7/32 0.010 0.25 0.032 0.81 0.287 7.29 26.0 15.2 1 26.3 47.5

C4176A 7 24 7/32 0.010 0.25 0.032 0.81 0.287 7.29 26.0 15.2 1 26.3 47.5

C4177A 8 24 7/32 0.010 0.25 0.032 0.81 0.309 7.85 26.0 15.0 1 26.3 47.5

C4178A 9 24 7/32 0.010 0.25 0.032 0.81 0.331 8.41 26.0 15.0 1 26.3 47.5

C4179A 10 24 7/32 0.010 0.25 0.032 0.81 0.359 9.12 26.0 14.0 1 26.3 47.5

C4180A 15 24 7/32 0.010 0.25 0.032 0.81 0.410 10.41 26.0 13.8 1 26.3 47.5

C4181A 19 24 7/32 0.010 0.25 0.032 0.81 0.432 10.97 26.0 13.5 1 26.3 47.5

C4182A 25 24 7/32 0.010 0.25 0.032 0.81 0.505 12.83 26.0 12.7 1 26.3 47.5*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFPAIRS COLOR

NO. OFPAIRS COLOR

1 BlackwithRed 14 GreenwithWhite

2 BlackwithWhite 15 Green with Blue

3 Black with Green 16 GreenwithYellow

4 Black with Blue 17 Green with Brown

5 BlackwithYellow 18 Green with Orange

6 Black with Brown 19 WhitewithBlue

7 Black with Orange 20 WhitewithYellow

8 RedwithWhite 21 WhitewithBrown

9 RedwithGreen 22 WhitewithOrange

10 RedwithBlue 23 BluewithYellow

11 RedwithYellow 24 Blue with Brown

12 RedwithBrown 25 Blue with Orange

13 RedwithOrange

Page 65: Cross-Reference & Online Spec Sheets - Datasheet Archive

54

Electronics Communication & Control Cable, Multi-Paired

Multi-Paired, Foil Shield AWMStyle2464,CSATypeAWMI/IIA/B,NEC/CECTypeCMG(CSAC/US)

Product Construction: Conductor: •22AWGfullyannealedstrandedtinned

copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-codedPVC •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester,

25%overlap,foilfacingout •Strandedtinnedcopperdrainwire

Jacket: •PVC,gray •Temperaturerange:-20°Cto+105°C

Applications: •Computers •Industrialequipment •Datatransmission •Controlcircuits •SuitableforEIARS-232applications •Suggestedvoltageratings:300or600

volts

Features: •Excellentelectricalproperties •Superiorshieldingeffectiveness •25%shieldoverlapprovidesexcellent

shielding efficiency •Assistssystemdesignersinmeeting

FCCDocket20780demands •Goodflexibility

Compliances: •AWMStyle2464(CSA:80˚C,300V) •CSATypeAWM(105˚C,600V) •CSACertifiedCMGtoharmonized

standard UL444 and CSA 22.2 No. 214 •NEC/CECTypeCMG(CSA:105˚C,300V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetCSA70,000BTU

VerticalTrayFlameTest •PassesCSAFT4VerticalFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OF

PAIRSAWGSIZE

COND.STRAND

NOMINAL INSULATION THICKNESS

NOMINAL JACKET

THICKNESSNOMINAL

O.D.

NOMINAL DCR Ω/kft

NOMINAL CAP.*pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

C4183A 1 22 7/30 0.010 0.25 0.032 0.81 0.169 4.29 15.0 18.0 44.8 80.7

C4184A 2 22 7/30 0.010 0.25 0.032 0.81 0.234 5.94 15.0 16.5 35.9 64.6

C4185A 3 22 7/30 0.010 0.25 0.032 0.81 0.246 6.25 15.0 16.5 30.9 55.7

C4186A 4 24 7/30 0.010 0.25 0.032 0.81 0.269 6.83 15.0 16.5 30.9 55.7

C4187A 5 22 7/30 0.010 0.25 0.032 0.81 0.294 7.47 15.0 16.5 30.9 55.7

C4188A 6 22 7/30 0.010 0.25 0.032 0.81 0.320 8.13 15.0 16.5 28.4 51.0

C4189A 9 22 7/30 0.010 0.25 0.032 0.81 0.367 9.32 15.0 16.5 28.4 51.0

C4190A 15 22 7/30 0.010 0.25 0.032 0.81 0.457 11.61 15.0 16.5 28.4 51.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFPAIRS COLOR

NO. OFPAIRS COLOR

1 BlackwithRed 9 RedwithGreen

2 BlackwithWhite 10 RedwithBlue

3 Black with Green 11 RedwithYellow

4 Black with Blue 12 RedwithBrown

5 BlackwithYellow 13 RedwithOrange

6 Black with Brown 14 GreenwithWhite

7 Black with Orange 15 Green with Blue

8 RedwithWhite

Page 66: Cross-Reference & Online Spec Sheets - Datasheet Archive

55

Communication & Control Cable, Multi-Paired Electronics

Multi-Paired, Foil Shield, Mid-Cap NEC Type CMP (UL) c(UL)

Product Construction: Conductor: •24AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-coded

fluoropolymer •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester foil

with25%overlap,minimum •Strandedtinnedcopperdrainwire

Jacket: •Fluoropolymer,natural •Temperaturerange:-40°Cto+150°C •Sequentialfootagemarkedtofacilitate

installation •Includesripcord

Applications: •EIARS-232andRS-422circuits •Remotecontrolcircuits •Processcontrolandinstrumentation •Power-limitedcontrolcircuits •Suggestedvoltagerating:300volts

Compliances: •NECArticle800(UL:150°C,300V) •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Abrasion-,chemical-andwater-resistant

jacket

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C3214 2 24 7/32 0.010 0.25 0.010 0.25 0.150 3.81 17.0 30.0

C3215 3 24 7/32 0.010 0.25 0.010 0.25 0.177 4.50 15.0 27.0

C3216 4 24 7/32 0.010 0.25 0.010 0.25 0.201 5.11 15.0 27.0

C3217 4.5 24 7/32 0.010 0.25 0.010 0.25 0.214 5.18 15.0 27.0

C3218 6 24 7/32 0.010 0.25 0.010 0.25 0.239 6.07 14.0 25.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFPAIRS COLOR

1 BlackpairedwithYellow

2 RedpairedwithViolet

3 DarkBluepairedwithBrown

4 OrangepairedwithDarkGreen

5 Pink paired with Gray

6 TanpairedwithWhite

1C GreenwithYellowStripe

Page 67: Cross-Reference & Online Spec Sheets - Datasheet Archive

56

Electronics Communication & Control Cable, Multi-Paired

Multi-Paired, Foil Shield, Lo-Cap® NEC Type CMP (UL) c(UL)

Product Construction: Conductor: •24AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-coded

fluoropolymer •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester foil

with25%overlap,minimum •Strandedtinnedcopperdrainwire

Jacket: •Fluoropolymer,natural •Temperaturerange:-40°Cto+150°C •Sequentialfootagemarkedtofacilitate

installation •Includesripcord

Applications: •EIARS-232andRS-422circuits •Remotecontrolcircuits •Processcontrolandinstrumentation •Lowcapacitancerequirements •Suggestedvoltagerating:300volts

Compliances: •NECArticle800(UL:150°C,300V) •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Abrasion-,chemical-andwater-resistant

jacket

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

IMPED.Ω

NOMINCHES mm INCHES mm A B

C3028 2 24 7/32 0.010 0.25 0.159 4.04 15.0 27.00 94.0

C3029 3 24 7/32 0.010 0.25 0.183 4.65 14.0 25.00 107.0

C3030 4 24 7/32 0.010 0.25 0.246 6.25 14.0 25.00 107.0

C3031 6 24 7/32 0.012 0.30 0.285 7.24 13.0 23.00 115.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFPAIRS COLOR

1 BlackpairedwithYellow

2 RedpairedwithViolet

3 DarkBluepairedwithBrown

4 OrangepairedwithDarkGreen

5 Pink paired with Gray

6 TanpairedwithWhite

Page 68: Cross-Reference & Online Spec Sheets - Datasheet Archive

57

Communication & Control Cable, Multi-Paired Electronics

Multi-Paired, Overall Foil & TC Braid Shield, Lo-Cap® NEC Type CMP (UL) c(UL)

Product Construction: Conductor: •24AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedfoamFEP •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester foil

with25%overlap,minimum •Tinnedcopperbraid,90%coverage

Jacket: C8117 •FEP,redorasrequested •Temperaturerange:-40°Cto+200°C

C8129 •Flexguard®PVC,natural •Temperaturerange:-20°Cto+75°C

Applications: •Computersystems •Remotecontrolcircuits •Processcontrolandinstrumentation •Suggestedvoltagerating:300volts

Compliances: •NECArticle800 •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Fire-retardant,low-smokejacket

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C8117 1 24 7/32 0.026 0.66 0.014 0.36 0.208 5.28 12.0 22.0

C8129 2 24 7/32 0.019 0.48 0.017 0.43 0.280 6.93 12.0 22.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartC8117

NO. OF PAIRS COLOR

1 White/BluepairedwithBlue/White

C8129NO. OF PAIRS COLOR

1 White/BluepairedwithBlue/White

2 White/OrangepairedwithOrange/White

Page 69: Cross-Reference & Online Spec Sheets - Datasheet Archive

58

Electronics Communication & Control Cable, Multi-Paired

Multi-Paired, Individually Shielded UL2717,UL2835,NECTypeCM(UL)c(UL)CMHorCMG

Product Construction: Conductor: •22AWGfullyannealedstrandedtinned

copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-coded

polypropylene •Colorcode:Seechartbelow

Shield: •Individuallyshieldedpairs •100%Flexfoil® aluminum/polyester,

25%overlap,foilfacingout •Strandedtinnedcopperdrainwire

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+80˚C

Applications: •Wheretotalisolationofsignalisrequired •Computers •Controlcircuits •Industrialequipment •Suggestedvoltagerating:300volts

Features: •Excellenthighfrequencyproperties •Mechanicaldurability

Compliances: •NECArticle800TypeCM(UL:75˚C,

300V) •ULStyle2717(UL:80˚C) •ULStyle2835(UL:60˚C,30V) •ULStyle2464(UL:80˚C,300V) •CSACMH(CSA:60˚C) •CSACMG(CSA:60˚C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetCSA70,000BTU

VerticalTrayFlameTest •PassesCSACMHorCMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Color Code ChartNO. OFPAIRS COLOR

1 Black/Red

2 Green/White

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOMINAL CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

POLYPROPYLENE INSULATION — NEC TYPE CM(UL) c(UL) CMH

C1352A 2 22 7/30 0.007 0.18 0.020 0.51 0.160 4.06 30.0 45.0

POLYPROPYLENE INSULATION — UL STYLE 2717, UL STYLE 2835, CM(UL) c(UL) CMH

C1353A** 2 22 7/30 0.010 0.25 0.028 0.71 0.208 5.028 25.0 53.5

SR-PVC INSULATION — UL STYLE 2464, CM(UL) c(UL) CMG

C7106A 2 20 7/28 0.010 0.25 0.041 1.04 0.305 7.75 46.0 82.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield**Individually shielded with overall shield

Page 70: Cross-Reference & Online Spec Sheets - Datasheet Archive

59

Communication & Control Cable, Multi-Paired Electronics

Multi-Paired, Individually Shielded CSATypeAWMI/IIA/B,NEC/CECTypeCMG(CSAC/US)

Product Construction: Conductor: •22AWGfullyannealedstrandedtinned

copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-codedPVC •Colorcode:Seechartbelow

Shield: •Individuallyshieldedpairs •100%Flexfoil® aluminum/polyester,

25%overlap,foilfacingout •Strandedtinnedcopperdrainwire

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+105˚C

Applications: •Wheretotalisolationofsignalisrequired •Computers •Controlcircuits •Industrialequipment •Suggestedvoltagerating:300or600

volts

Features: •Excellenthigh-frequencyproperties •Mechanicaldurability

Compliances: •CSATypeAWM(105˚C,600V) •CSACertifiedCMGtoharmonized

standard UL444 and CSA (22.2 No. 2) •NEC/CECTypeCMG(CSA:105˚C,300V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetCSA70,000BTU

VerticalTrayFlameTest •PassesCSAFT4VerticalFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OF

PAIRSAWGSIZE

COND.STRAND

NOMINAL INSULATION THICKNESS

NOMINAL JACKET

THICKNESSNOMINAL

O.D.

NOMINAL DCR Ω/kft

NOMINAL CAP.*pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

C4203A 2 22 7/30 0.007 0.18 0.020 0.51 0.160 4.06 16.6 7.2 67.0 121.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFPAIRS COLOR

1 BlackwithRed

2 GreenwithWhite

Page 71: Cross-Reference & Online Spec Sheets - Datasheet Archive

60

Electronics Communication & Control Cable, Multi-Paired

Multi-Paired, Individually Shielded, Overall Shield UL2464,UL2576,NECTypeCMR(UL)c(UL),CSACMG

Product Construction: Conductor: •22AWGfullyannealedstrandedtinned

copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-codedS-RPVC

per UL 1061 •Colorcode:Seechartbelow

Shield: •Individuallyshieldedpairsplusanoverall

foil shield and drain wire •100%Flexfoil® aluminum/polyester,

25%overlap,foilfacingin •Strandedtinnedcopperdrainwire

Jacket: •PVC,beige •Temperaturerange:-20˚Cto+80˚C

Applications: •Computerinterconnections •Datatransmission •Controlcircuits •Industrialequipmentcontrol •Suggestedvoltagerating:300volts

Features: •Excellenthighfrequencyproperties •Mechanicaldurability

Compliances: •NECArticle800TypeCMR(UL:75˚C) •ULStyle2464(UL:80˚C,300V) •ULStyle2576 •CSACMG(CSA:60°C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOMINAL CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C1350A 2 22 7/30 0.010 0.25 0.035 0.889 0.175x

0.280

4.45x

7.11

40 71.5

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFPAIRS COLOR

1 Black/White

2 Black/Yellow

Page 72: Cross-Reference & Online Spec Sheets - Datasheet Archive

61

Communication & Control Cable, Multi-Paired Electronics

Multi-Paired, Individually Foil Shielded NEC Type CMP (UL) c(UL)

Product Construction: Conductor: •22AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-coded

fluoropolymer •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester foil,

eachwith25%overlap,minimum •Strandedtinnedcopperdrainwire

Jacket: •Fluoropolymer,red •Temperaturerange:-20°Cto+150°C •Sequentialfootagemarkedtofacilitate

installation •Includesripcord

Applications: •Pointofsalesystems •Remotecontrolcircuits •Processcontrolandinstrumentation •Power-limitedcontrolcircuits •Suggestedvoltagerating:300volts

Compliances: •NECArticle800(UL:150°C,300V) •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Individuallyshieldedpairsforexcellent

signal isolation •Abrasion-,chemical-andwater-resistant

jacket

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.**pF/ft

INCHES mm INCHES mm INCHES mm A B

C3156* 2 22 7/30 0.006 0.15 0.010 0.25 0.147 3.73 35.0 63.0

C3157† 3 22 7/30 0.006 0.15 0.010 0.25 0.184 4.67 35.0 63.0

*Cabledoncommonaxistoreducediameter,foilout,commondrainwire ** A – Capacitance between conductors ** B – Capacitance between one conductor and other conductors connected to shield † 3 individually shielded pairs with separate drain wires

Color Code ChartC3156

NO. OF PAIRS COLOR

1 BlackpairedwithRed

2 WhitepairedwithGreen

C3157NO. OF PAIRS COLOR

1 BlackpairedwithRed

2 BlackpairedwithWhite

3 Black paired with Green

Page 73: Cross-Reference & Online Spec Sheets - Datasheet Archive

62

Electronics Communication & Control Cable, Multi-Paired

Multi-Paired, Individually Foil Shielded NEC Type CMP (UL) c(UL)

Product Construction: Conductor: •24thru22AWGfullyannealedstranded

tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedFEPor

foamed FEP •Colorcode:Seechartbelow

Pair Shield: •100%Flexfoil® aluminum/polyester foil,

with25%overlap,minimum •Individuallyshieldedpairswithstranded

tinned copper drain wire

Jacket: •Flexguard®PVC,natural •Temperaturerange:-20°Cto+75°C

Applications: •Computersystems •Remotecontrolcircuits •Processcontrolandinstrumentation •Suggestedvoltagerating:300volts

Compliances: •NECArticle800 •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Individuallyshieldedpairsforexcellent

signal isolation •Fire-retardant,low-smokejacket

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C8134 2 24 7/32 0.019 0.48 0.015 0.38 0.255 7.48 35.0 76.0

C8105 2 22 7/30 0.006 0.15 0.014 0.36 0.186 4.72 43.0 75.0

C8131 3 22 7/30 0.010 0.25 0.018 0.46 0.237 6.02 35.0 76.0

C8133 6 22 7/30 0.010 0.25 0.018 0.45 0.314 7.98 35.0 76.0

*A – Capacitance between conductors *B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartC8105

NO. OF PAIRS COLOR

1 BlackpairedwithRed

2 WhitepairedwithGreen

C8131NO. OF PAIRS COLOR

1 BlackpairedwithRed

2 BlackpairedwithWhite

3 Black paired with Green

C8133NO. OF PAIRS COLOR

1 BlackpairedwithRed

2 BlackpairedwithWhite

3 Black paired with Green

4 Black paired with Blue

5 BlackpairedwithYellow

6 Black paired with Brown

C8134NO. OF PAIRS COLOR

1 White/BluepairedwithBlue/White

2 White/OrangepairedwithOrange/White

Page 74: Cross-Reference & Online Spec Sheets - Datasheet Archive

63

Communication & Control Cable, Multi-Paired Electronics

Multi-Paired, Individually Foil Shielded NEC Type CMP (UL) c(UL)

Product Construction: Conductor: •22AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedFEP •Colorcode:Seechartbelow

Pair Shield: •100%Flexfoil® aluminum/polyester foil,

with25%overlap,minimum •Individuallyshieldedpairswithstranded

tinned copper drain wire

Jacket: •FEP,redorasrequested •Temperaturerange:-40°Cto+200°C

Applications: •Computersystems •Remotecontrolcircuits •Processcontrolandinstrumentation •Suggestedvoltagerating:300volts

Compliances: •NECArticle800 •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Individuallyshieldedpairsforexcellent

signal isolation •Fire-retardant,low-smokejacket

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C8112 2 22 7/30 0.006 0.15 0.014 0.36 0.186 4.72 35.0 65.0

C8132 6 22 7/30 0.010 0.25 0.015 0.38 0.309 7.85 30.0 65.0

*A – Capacitance between conductors *B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartC8112

NO. OF PAIRS COLOR

1 BlackpairedwithRed

2 WhitepairedwithGreen

C8132NO. OF PAIRS COLOR

1 BlackpairedwithRed

2 BlackpairedwithWhite

3 Black paired with Green

4 Black paired with Blue

5 BlackpairedwithYellow

6 Black paired with Brown

Page 75: Cross-Reference & Online Spec Sheets - Datasheet Archive

64

Electronics Communication & Control Cable, Multi-Paired

Multi-Paired, Individually Foil Shielded NEC Type CMP (UL) c(UL)

Product Construction: Conductor: •24AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedfoamFEP •Colorcode:Seechartbelow

Pair Shield: •100%Flexfoil® aluminum/polyester foil

with25%overlap,minimum •Individuallyshieldedpairswithstranded

tinned copper drain wire

Jacket: •PVDF,grayorasrequested •Temperaturerange:-40°Cto+150°C

Applications: •Computersystems •Remotecontrolcircuits •Processcontrolandinstrumentation •Suggestedvoltagerating:300volts

Compliances: •NECArticle800 •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Individuallyshieldedpairsforexcellent

signal isolation •Fire-retardant,low-smokejacket

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C8128 2 24 7/32 0.019 0.48 0.018 0.46 0.261 6.63 12.5 22.0

*A – Capacitance between conductors *B – Capacitance between one conductor and other conductors connected to shield

Color Code Chart

NO. OF PAIRS COLOR

1 White/BluepairedwithBlue/White

2 White/OrangepairedwithOrange/White

Page 76: Cross-Reference & Online Spec Sheets - Datasheet Archive

65

Communication & Control Cable, Multi-Paired Electronics

Power-Limited Tray Cable, Individually Shielded UL2464,NECTypePLTCANDCSACMG

Product Construction: Conductor: •22or18AWGfullyannealedstranded

tinned copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-codedPVC •Colorcode:Eachpairblackandred,

numbered at one-inch intervals

Shield: •Pairsare100%individuallyshieldedwith

Flexfoil® aluminum/polyester, foil facing in •Strandedtinnedcopperdrainwireeach

pair

Jacket: •PVC,gray •Temperaturerange:-20°Cto+105°C

Applications: •Power-limitedcircuits •Intercomsystems •Businessmachines •Cashregisters •Computerinterconnects •Suitablymarkedforappropriatetray

cable installations •Burglaralarms •Suggestedvoltagerating:300volts

Features: •Superiortemperaturecharacteristics •Robust,highlydurable •Sunlight-resistantjacket

Compliances: •NECArticle725Power-LimitedTray

Cable(UL:105°C,300V) •ULStyle2464(UL:80°C) •CSACMG(CSA:60°C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Color Code ChartNO. OFPAIRS COLOR

1 thru 15 Black Red

Each pair marked and numbered

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOMINAL CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C0570A 2 22 7/30 0.016 0.41 0.042 1.07 0.327 8.31 38.5 69.5

C0571A 3 22 7/30 0.015 0.41 0.042 1.07 0.345 8.76 38.5 69.5

C0572A 4 22 7/30 0.015 0.41 0.042 1.07 0.378 9.60 38.5 69.5

C0573A 6 22 7/30 0.015 0.41 0.053 1.35 0.469 11.91 38.5 69.5

C0574A 9 22 7/30 0.015 0.41 0.053 1.35 0.542 13.77 38.5 69.5

C0575A 11 22 7/30 0.015 0.41 0.053 1.35 0.589 14.96 38.5 69.5

C0584A 2 18 16/30 0.016 0.41 0.042 1.07 0.380 9.65 50.5 91.0

C0585A 3 18 16/30 0.016 0.41 0.053 1.35 0.437 11.10 50.5 91.0

C0586A 4 18 16/30 0.016 0.41 0.053 1.35 0.478 12.14 50.5 91.0

C0587A 6 18 16/30 0.016 0.41 0.053 1.35 0.566 14.38 50.5 91.0

C0588A 9 18 16/30 0.016 0.41 0.063 1.60 0.679 17.25 50.5 91.0

C0589A 11 18 16/30 0.016 0.41 0.063 1.60 0.738 18.75 50.5 91.0

C0590A 15 18 16/30 0.015 0.38 0.063 1.60 0.845 21.46 50.5 91.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Page 77: Cross-Reference & Online Spec Sheets - Datasheet Archive

66

Electronics Communication & Control Cable, Multi-Paired

Power-Limited Tray Cable, Foil Shield or Foil/Braid Shield UL 2464, NEC Type PLTC/CM, CSA CMG

Product Construction: Conductor: •22or18AWGfullyannealedstranded

tinned copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-codedPVCor

FMPE •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester,

25%overlap,foilfacingout •Strandedtinnedcopperdrainwire •65%tinnedcopperbraid(C7101A,

C7103A and C7107A only)

Jacket: •PVC,grayorblack •Temperaturerange:

-20°Cto+60°Cor+105°C

Applications: •Power-limitedcircuits •Intercomsystems •Businessmachines •Computerinterconnects •Suitablymarkedforappropriatetray

cable installations •Petrochemicalcontrolsystems •Burglaralarms •Suggestedvoltagerating:300volts

Features: •Superiortemperaturecharacteristics •Robust,highlydurable •Sunlight-resistantjacket

Compliances: •NECArticle725Power-LimitedTray

Cable(UL:105°Cor60°C,300V) •NECArticle800CommunicationsCable

(UL:105°Cor60°C,300V) •†ULStyle2464(UL:80°C,300V) •CSACMG(CSA:60°C)orCMc(UL) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

† ULStyle2464onlyavailableonPVCinsulation constructions

LO-CAP® DATACOM COLOR CODE WITH 65% TINNED COPPER BRAID

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOMINAL CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

FOAMED POLYETHYLENE INSULATION — NEC TYPE PLTC/CM, CEC CM c(UL), 60°C

C7112A 1 22 7/.0096 0.024 0.61 0.037 0.94 0.261 6.63 11.5 20.5C7114A 2 22 7/.0096 0.017 0.43 0.042 1.07 0.343 8.71 11.0 19.6C7116A 3 22 7/.0096 0.015 0.38 0.042 1.07 0.344 8.74 11.0 19.6

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFPAIRS COLOR

1 thru 9 Black/RedEach pair marked and numbered

Color Code ChartNO. OFPAIRS COLOR

1 White/BlueStripeandBlue/WhiteStripe2 White/OrangeStripeandOrange/WhiteStripe3 White/GreenStripeandGreen/WhiteStripe

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOMINAL CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

PVC INSULATION — UL STYLE 2464, NEC TYPE PLT/CM, CSA CMG, 105°CC0550A 2 22 7/.0096 0.015 0.38 0.042 1.07 0.294 7.47 32.0 57.0C0551A 3 22 7/.0096 0.015 0.38 0.042 1.07 0.309 7.85 29.0 52.2C0552A 4 22 7/.0096 0.015 0.38 0.042 1.07 0.337 8.56 29.0 52.2C0553A 6 22 7/.0096 0.015 0.38 0.042 1.35 0.418 10.62 26.5 47.7C0554A 9 22 7/.0096 0.015 0.38 0.042 1.35 0.480 12.19 26.5 47.7C0555A 11 22 7/30 0.015 0.38 0.053 1.35 0.520 13.21 27.0 48.5C0556A 15 22 7/30 0.015 0.38 0.053 1.35 0.592 15.04 27.0 48.5C0560A 2 18 16/30 0.016 0.41 0.042 1.07 0.314 7.98 40.0 72.0C0561A 3 18 16/30 0.016 0.41 0.042 1.35 0.403 10.24 33.5 60.3C0562A 4 18 16/30 0.016 0.41 0.042 1.35 0.440 11.18 33.5 60.3C0563A 6 18 16/30 0.016 0.41 0.042 1.35 0.519 13.18 30.5 54.9C0564A 9 18 16/30 0.016 0.41 0.042 1.60 0.622 15.80 30.5 54.9C0566A 15 18 16/30 0.016 0.41 0.042 1.60 0.622 15.80 30.5 54.9

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Page 78: Cross-Reference & Online Spec Sheets - Datasheet Archive

67

Electronics

Index Page

Multi-Conductor, Foil Shield 68-69

Multi-Conductor, Foil/Braid Shield 70-71

Multi-Conductor, Foil/Braid Shield, Lo-Cap® 72

Multi-Paired, Foil Shield 73

Multi-Paired, Foil Shield, Lo-Cap® 74

Multi-Paired, Foil/Braid Shield 75

Multi-Paired, Foil/Braid Shield, Lo-Cap® 76-79

Multi-Paired, Individually Foil Shielded 80-82

Multi-Paired, Individually Foil Shielded, Lo-Cap® 83

Multi-Paired, Individually Foil/Braid Shielded, Lo-Cap® 84

General Cable manufactures a comprehensive line of computer cables.

This complete line of paired and unpaired, shielded computer cables—which are UL and CSA listed—are used primarily for the internal or external interconnection of electronic equipment and computers. Applications include data transmission, CAD/CAM, telemetering, data displays, computer print-out, credit verification systems and similar applications.

General Cable also offers a variety of put-ups for computer cables to meet your individual requirements.

Our products are manufactured to meet the latest UL, CSA and NEC requirements and approvals.

Computer Cable 4

Page 79: Cross-Reference & Online Spec Sheets - Datasheet Archive

68

Electronics Computer Cable

Product Construction: Conductor: •24AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedS-RPVC

per UL 1061 •Colorcode:Seechartsbelow

Shield: •100%Flexfoil® aluminum/polyester

with25%overlap,foilfacingout •Strandedtinnedcopperdrainwire

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+80˚C

Applications: •Computerinterconnections •Datatransmission •Controlcircuits •Industrialequipmentcontrol •SuitableforEIARS-232applications •Suggestedvoltagerating:300volts

Compliances: •NECArticle800TypeCMR(UL:75˚C) •ULStyle2464(UL:80°C,300V) •CSACMG(CSA:60°C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Multi-Conductor, Foil Shield UL2464,NECTypeCMR(UL)c(UL),CSACMG

CATALOG NUMBER

NO. OF

COND.AWGSIZE

COND.STRAND

NOMINAL INSULATION THICKNESS

NOMINAL JACKET

THICKNESSNOMINAL

O.D.

NOMINAL DCR Ω/kft @20˚C

NOMINAL CAP.*pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

C0740A 2 24 7/32 0.010 0.25 0.032 0.81 0.157 3.99 26.0 7.2 36.0 64.0C0741A 3 24 7/32 0.010 0.25 0.032 0.81 0.164 4.17 26.0 7.2 33.0 59.0C0742A 4 24 7/32 0.010 0.25 0.032 0.81 0.175 4.45 26.0 7.2 33.0 59.0C0753A 5 24 7/32 0.010 0.25 0.032 0.81 0.188 4.78 26.0 7.2 33.0 59.0C0743A 6 24 7/32 0.010 0.25 0.032 0.81 0.201 5.11 26.0 7.2 30.0 55.0C0754A 7 24 7/32 0.010 0.25 0.032 0.81 0.201 5.11 26.0 7.2 30.0 55.0C0744A 8 24 7/32 0.010 0.25 0.032 0.81 0.215 5.46 26.0 7.2 30.0 55.0C0755A 9 24 7/32 0.010 0.25 0.032 0.81 0.228 5.79 26.0 7.2 30.0 55.0C0745A 10 24 7/32 0.010 0.25 0.032 0.81 0.245 6.22 26.0 7.2 30.0 55.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

CATALOG NUMBER

NO. OF

COND.AWGSIZE

COND.STRAND

NOMINAL INSULATION THICKNESS

NOMINAL JACKET

THICKNESSNOMINAL

O.D.

NOMINAL DCR Ω/kft @20˚C

NOMINAL CAP.*pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

C0746A 15 24 7/32 0.010 0.25 0.032 0.81 0.276 7.01 26.0 7.2 30.0 55.0C0747A 20 24 7/32 0.010 0.25 0.032 0.81 0.303 7.70 26.0 7.2 30.0 55.0C0748A 25 24 7/32 0.010 0.25 0.032 0.81 0.333 8.46 26.0 7.2 30.0 55.0C0749A 30 24 7/32 0.010 0.25 0.032 0.81 0.351 8.92 26.0 7.2 30.0 55.0C0750A 40 24 7/32 0.010 0.25 0.032 0.81 0.391 9.93 26.0 7.2 30.0 55.0C0751A 50 24 7/32 0.010 0.25 0.032 0.81 0.439 11.15 26.0 7.2 30.0 55.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code Chart 1 - For cables up to and including 10 conductors

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 6 Light Blue2 White 7 Orange3 Red 8 Yellow4 Light Green 9 Violet5 Light Brown 10 Gray

Color Code Chart 2 Per ICEA - For cables of 15 thru 50 conductors

NO. OFCOND. COLOR

NO. OFCOND. COLOR

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 14 LightGreen/White 27 LightBlue/Black/White 39 White/Black/Green2 White 15 LightBlue/White 28 Black/Red/Green 40 Red/White/Green3 Red 16 Black/Red 29 White/Red/Green 41 LightGreen/White/Blue4 Light Green 17 White/Red 30 Red/Black/Green 42 Orange/Red/Green5 Orange 18 Orange/Red 31 Light Green/Black/Orange 43 LightBlue/Red/Green6 Light Blue 19 LightBlue/Red 32 Orange/Black/Green 44 Black/White/Blue7 White/Black 20 Red/Green 33 LightBlue/White/Orange 45 White/Black/Blue8 Red/Black 21 Orange/Green 34 Black/White/Orange 46 Red/White/Blue9 Light Green/Black 22 Black/White/Red 35 White/Red/Orange 47 LightGreen/Orange/Red

10 Orange/Black 23 White/Black/Red 36 Orange/White/Blue 48 Orange/Red/Blue11 Light Blue/Black 24 Red/Black/White 37 White/Red/Blue 49 LightBlue/Red/Orange12 Black/White 25 LightGreen/Black/White 38 Black/White/Green 50 Black/Orange/Red13 Red/White 26 Orange/Black/White

Page 80: Cross-Reference & Online Spec Sheets - Datasheet Archive

69

Computer Cable Electronics

Multi-Conductor, Foil Shield UL2464,NECTypeCM(UL)c(UL)orCMR(UL)c(UL),CSACMG

Product Construction: Conductor: •22or20AWGfullyannealedstranded

tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedS-RPVC

orPVC •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester with

25%overlap,minimum,foilfacingout •Strandedtinnedcopperdrainwire

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+80˚C

Applications: •Computerinterconnections •Datatransmission •Controlcircuits •Industrialequipmentcontrol •SuitableforEIARS-232applications •Suggestedvoltagerating:300volts

Compliances: •NECArticle800TypeCM-20or22

AWG(UL:75˚C) •NECArticle800TypeCMR-20or22

AWG(UL:75˚C) •ULStyle2464(UL:80˚C,300V) •CSACMG(CSA:60˚C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOMINAL INSULATION THICKNESS

NOMINAL JACKET

THICKNESSNOMINAL

O.D.

NOMINAL DCR Ω/kft @20˚C

NOMINAL CAP.*pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

S-R PVC – CMR (UL) c(UL)

C0760A 2 22 7/30 0.010 0.25 0.032 0.81 0.169 4.29 16.5 6.3 36.0 65.0

C0761A 3 22 7/30 0.010 0.25 0.032 0.81 0.177 4.50 16.5 6.3 36.0 65.0

C0762A 4 22 7/30 0.010 0.25 0.032 0.81 0.190 4.83 16.5 6.3 36.0 65.0

C0763A 6 22 7/30 0.010 0.25 0.032 0.81 0.219 5.56 16.5 6.3 34.0 61.0

C0764A 8 22 7/30 0.010 0.25 0.032 0.81 0.235 5.97 16.5 6.3 34.0 61.0

C0765A 10 22 7/30 0.010 0.25 0.032 0.81 0.269 6.83 16.5 6.3 34.0 61.0

C0766A 15 22 7/30 0.010 0.25 0.032 0.81 0.304 7.72 16.5 6.3 34.0 61.0

C0767A 20 22 7/30 0.010 0.25 0.032 0.81 0.335 8.51 16.5 6.3 34.0 61.0

C0768A 25 22 7/30 0.010 0.25 0.032 0.81 0.369 9.37 16.5 6.3 34.0 61.0

PVC – CM (UL) c(UL)

C0780A 2 20 7/28 0.016 0.41 0.032 0.81 0.207 5.26 11.0 6.3 39.0 70.0

C0781A 3 20 7/28 0.016 0.41 0.032 0.81 0.217 5.51 11.0 6.3 39.0 70.0

C0782A 4 20 7/28 0.016 0.41 0.032 0.81 0.236 5.99 11.0 6.3 39.0 70.0

C0783A 6 20 7/28 0.016 0.41 0.032 0.81 0.276 7.01 11.0 6.3 37.0 66.0

C0784A 8 20 7/28 0.016 0.41 0.032 0.81 0.297 7.54 11.0 6.3 37.0 66.0

C0785A 10 20 7/28 0.016 0.41 0.032 0.81 0.345 8.76 11.0 6.3 37.0 66.0

C0786A 15 20 7/28 0.016 0.41 0.032 0.81 0.393 9.98 11.0 6.3 37.0 66.0

C0787A 20 20 7/28 0.016 0.41 0.032 0.81 0.435 11.05 11.0 6.3 37.0 66.0

C0788A 25 20 7/28 0.016 0.41 0.032 0.81 0.483 12.27 11.0 6.3 40.0 72.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFCOND. COLOR

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 10 Orange/Black 19 Blue/Red

2 White 11 Blue/Black 20 Red/Green

3 Red 12 Black/White 21 Orange/Green

4 Green 13 Red/White 22 Black/White/Red

5 Orange 14 Green/White 23 White/Black/Red

6 Blue 15 Blue/White 24 Red/Black/White

7 White/Black 16 Black/Red 25 Green/Black/White

8 Red/Black 17 White/Red

9 Green/Black 18 Orange/Red

Page 81: Cross-Reference & Online Spec Sheets - Datasheet Archive

70

Electronics Computer Cable

Multi-Conductor, Foil/Braid Shield UL2464,NECTypeCL2(UL)orCM(UL)c(UL),CSACMG

Product Construction: Conductor: •28and24AWGfullyannealedstranded

tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedS-RPVC

per UL 1061 •Colorcode:Seechartsbelow

Shield: •100%Flexfoil® aluminum/polyester with

25%overlap,minimum,foilfacingout •Strandedtinnedcopperdrainwire

(28AWGonly) •65%tinnedcopperbraid

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+80˚C

Applications: •Computers •Industrialequipment •Datatransmission •Controlcircuits •SuitableforEIARS-232applications •Suggestedvoltagerating:300volts

Features: •Braidshieldprovidesgoodflexibility •Superiorshieldingwherenoiserejection

is critical •Assistssystemdesignersinmeeting

FCC Docket 20780 demands

Compliances: •NECArticle725TypeCL2-28AWG

(UL:75˚C) •NECArticle800TypeCM-24AWG

(UL:75˚C) •ULStyle2464(UL:80°C,300V) •CSACMG(CSA:60˚C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOMINAL INSULATION THICKNESS

NOMINAL JACKET

THICKNESSNOMINAL

O.D.

NOMINAL DCR Ω/kft @20˚C

NOMINAL CAP.**pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

CL2, CMG, UL 2464C0939A* 3 28 7/36 0.010 0.25 0.032 0.81 0.166 4.22 67.5 5.0 26.0 47.0C0940A* 4 28 7/36 0.010 0.25 0.032 0.81 0.176 4.47 67.5 5.0 26.0 47.0C0941A* 5 28 7/36 0.010 0.25 0.032 0.81 0.186 4.72 67.5 5.0 26.0 47.0C0942A* 6 28 7/36 0.010 0.25 0.032 0.81 0.196 4.98 67.5 5.0 25.0 44.0C0943A* 7 28 7/36 0.010 0.25 0.032 0.81 0.196 4.98 67.5 5.0 25.0 44.0C0944A* 8 28 7/36 0.010 0.25 0.032 0.81 0.207 5.26 67.5 5.0 25.0 44.0C0945A* 9 28 7/36 0.010 0.25 0.032 0.81 0.217 5.51 67.5 5.0 20.0 36.0C0946A* 10 28 7/36 0.010 0.25 0.032 0.81 0.231 5.87 67.5 5.0 20.0 36.0C0947A 15 28 7/36 0.010 0.25 0.032 0.81 0.256 6.50 67.5 5.0 20.0 36.0C0948A 25 28 7/36 0.010 0.25 0.032 0.81 0.301 7.65 67.5 5.0 20.0 36.0

CM, CMG, UL 2464C0951A 3 24 7/32 0.010 0.25 0.032 0.81 0.186 4.72 25.7 5.3 33.0 59.0C0952A 4 24 7/32 0.010 0.25 0.032 0.81 0.197 5.00 25.7 5.5 33.0 59.0C0953A 5 24 7/32 0.010 0.25 0.032 0.81 0.210 5.33 25.7 4.4 33.0 59.0C0954A 6 24 7/32 0.010 0.25 0.032 0.81 0.223 5.66 25.7 4.6 30.0 55.0C0955A 7 24 7/32 0.010 0.25 0.032 0.81 0.223 5.66 25.7 4.6 30.0 55.0C0956A 8 24 7/32 0.010 0.25 0.032 0.81 0.237 6.02 25.7 3.8 30.0 55.0C0957A 9 24 7/32 0.010 0.25 0.032 0.81 0.250 6.35 25.7 3.9 30.0 55.0C0958A 10 24 7/32 0.010 0.25 0.032 0.81 0.267 6.78 25.7 4.2 30.0 55.0C0959A 15 24 7/32 0.010 0.25 0.032 0.81 0.298 7.57 25.7 3.6 30.0 55.0C0960A 20 24 7/32 0.010 0.25 0.032 0.81 0.325 8.26 25.7 4.5 30.0 55.0C0961A 25 24 7/32 0.010 0.25 0.032 0.81 0.355 9.02 25.7 3.5 30.0 55.0*ColorCodeChart1.RemainingitemsColorCodeChart2**A – Capacitance between conductors**B – Capacitance between one conductor and other conductors connected to shield

Color Code Chart 2 Per ICEANO. OFCOND. COLOR

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 10 Orange/Black 19 LightBlue/Red2 White 11 Light Blue/Black 20 Red/Green3 Red 12 Black/White 21 Orange/Green4 Light Green 13 Red/White 22 Black/White/Red5 Orange 14 LightGreen/White 23 White/Black/Red6 Light Blue 15 LightBlue/White 24 Red/Black/White7 White/Black 16 Black/Red 25 LightGreen/Black/White8 Red/Black 17 White/Red9 Light Green/Black 18 Orange/Red

Color Code Chart 1NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 6 Light Blue2 White 7 Orange3 Red 8 Yellow4 Light Green 9 Violet5 Light Brown 10 Gray

Page 82: Cross-Reference & Online Spec Sheets - Datasheet Archive

71

Computer Cable Electronics

Multi-Conductor, Foil/Braid Shield UL2464,NECTypeCMR(UL)c(UL),CSACMG

Product Construction: Conductor: •22AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedS-RPVC

per UL 1061 •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester with

25%overlap,minimum,foilfacingout •65%tinnedcopperbraid

Jacket: •PVC,gray •Temperaturerange:-20°Cto+80˚C

Applications: •Computers •Industrialequipment •Datatransmission •Controlcircuits •SuitableforEIARS-232applications •Suggestedvoltagerating:300volts

Features: •Braidshieldprovidesgoodflexibility •Superiorshieldingwherenoiserejection

is critical •Assistssystemdesignersinmeeting

FCC Docket 20780 demands

Compliances: •NECArticle800TypeCMR(UL:75˚C) •ULStyle2464(UL:80°C,300V) •CSACMG(CSA:60˚C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOMINAL INSULATION THICKNESS

NOMINAL JACKET

THICKNESSNOMINAL

O.D.

NOMINAL DCR Ω/kft @20˚C

NOMINAL CAP.*pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

C0971A 3 22 7/30 0.010 0.25 0.032 0.81 0.199 5.05 16.6 5.6 36.0 66.0

C0972A 4 22 7/30 0.010 0.25 0.032 0.81 0.212 5.38 16.6 4.4 36.0 66.0

C0973A 5 22 7/30 0.010 0.25 0.032 0.81 0.226 5.74 16.6 4.7 36.0 66.0

C0974A 6 22 7/30 0.010 0.25 0.032 0.81 0.241 6.12 16.6 3.8 34.0 60.0

C0975A 7 22 7/30 0.010 0.25 0.032 0.81 0.241 6.12 16.6 6.2 34.0 60.0

C0976A 8 22 7/30 0.010 0.25 0.032 0.81 0.257 6.53 16.6 4.0 34.0 60.0

C0977A 9 22 7/30 0.010 0.25 0.032 0.81 0.272 6.91 16.6 3.4 34.0 60.0

C0978A 10 22 7/30 0.010 0.25 0.032 0.81 0.291 7.39 16.6 3.6 34.0 60.0

C0979A 15 22 7/30 0.010 0.25 0.032 0.81 0.326 8.28 16.6 3.6 34.0 60.0

C0980A 20 22 7/30 0.010 0.25 0.032 0.81 0.357 9.07 16.6 3.9 34.0 60.0

C0981A 25 22 7/30 0.010 0.25 0.032 0.81 0.391 9.93 16.6 2.7 34.0 60.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code Chart Per ICEA

NO. OFCOND. COLOR

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 10 Orange/Black 19 LightBlue/Red

2 White 11 Light Blue/Black 20 Red/Green

3 Red 12 Black/White 21 Orange/Green

4 Light Green 13 Red/White 22 Black/White/Red

5 Orange 14 LightGreen/White 23 White/Black/Red

6 Light Blue 15 LightBlue/White 24 Red/Black/White

7 White/Black 16 Black/Red 25 LightGreen/Black/White

8 Red/Black 17 White/Red

9 Light Green/Black 18 Orange/Red

Page 83: Cross-Reference & Online Spec Sheets - Datasheet Archive

72

Electronics Computer Cable

Multi-Conductor, Foil/Braid Shield, Lo-Cap® UL2919,NECTypeCL2orCM(UL)c(UL)CMH,CSACMH

Color Code Chart 1 - For cables up to and including 10 conductors

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 6 Light Blue2 White 7 Orange3 Red 8 Yellow4 Light Green 9 Violet5 Brown 10 Gray

Product Construction: Conductor: •28and24AWGfullyannealedstranded

tinned copper per ASTM B-33

Insulation: •PremiumgradefoamedLo-Cap® color

coded polypropylene •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester with

25%overlap,minimum,foilfacingout •Strandedtinnedcopperdrainwire •70%tinnedcopperbraid

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+80˚C

Applications: •Highspeedcomputers •Industrialequipment •Controlcircuits •Designedforlowcapacitance

applications •SuitableforEIARS-232andRS-423

CAD/CAM applications •Suggestedvoltagerating:30volts

Features: •Braidshieldprovidesgoodflexibility •Superiorshieldingwherenoiserejection

is critical •Assistssystemdesignersinmeeting

FCC Docket 20780 demands

Compliances: •NECArticle800TypeCM(UL:75˚C) •ULStyle2919(UL:80˚C,30V) •CSACMH(CSA:60˚C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMHFlameTest

Packaging: •1000'(305m)spoolsorreels •500'(152m)spoolsorreels •Otherput-upsavailable—consult

Customer Service

CATALOG NUMBER

NO. OF

COND.

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS

NOMINAL O.D.

NOMINAL DCR Ω/kft

NOMINAL CAP.*pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

28 AWG (7/36): CL2, CSA CMHC0530A 3 0.016 0.41 0.032 0.81 0.192 4.88 64.9 7.8 9.5 17.0

C0531A 4 0.016 0.41 0.032 0.81 0.205 5.21 64.9 5.9 9.5 17.0

C0532A 5 0.016 0.41 0.032 0.81 0.218 5.54 64.9 5.9 9.5 17.0

C0533A 6 0.016 0.41 0.032 0.81 0.232 5.89 64.9 6.2 9.0 16.0

C0534A 7 0.016 0.41 0.032 0.81 0.232 5.89 64.9 6.2 9.0 16.0

C0535A 8 0.016 0.41 0.032 0.81 0.247 6.27 64.9 4.8 9.0 16.0

C0536A 9 0.016 0.41 0.032 0.81 0.261 6.63 64.9 4.9 9.0 16.0

C0537A 10 0.016 0.41 0.032 0.81 0.279 7.09 64.9 5.2 9.0 16.0

C0538A 15 0.016 0.41 0.032 0.81 0.312 7.92 64.9 4.2 9.0 16.0

24 AWG (7/32): CM (UL) c(UL) CMH, AWM Style 2919C0680A 3 0.016 0.41 0.032 0.81 0.211 5.36 25.7 3.8 11.9 21.5

C0681A 4 0.016 0.41 0.032 0.81 0.227 5.77 25.7 3.8 11.9 21.5

C0682A 5 0.016 0.41 0.032 0.81 0.242 6.15 25.7 3.8 11.9 21.5

C0683A 6 0.016 0.41 0.032 0.81 0.259 6.58 25.7 3.2 11.2 20.2

C0684A 7 0.016 0.41 0.032 0.81 0.259 6.58 25.7 3.2 11.2 20.2

C0685A 8 0.016 0.41 0.032 0.81 0.276 7.01 25.7 3.2 11.2 20.2

C0686A 9 0.016 0.41 0.032 0.81 0.293 7.44 25.7 3.6 11.2 20.2

C0687A 10 0.016 0.41 0.032 0.81 0.315 8.00 25.7 3.6 11.2 20.2

C0688A 15 0.016 0.41 0.032 0.81 0.354 8.99 25.7 3.6 11.2 20.2*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shieldVp=78%Impedance:≈100 Ω

Color Code Chart 2 Per ICEA - For cables up to 15 conductors

NO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 10 Orange/Black2 White 11 Light Blue/Black3 Red 12 Black/White4 Light Green 13 Red/White5 Orange 14 LightGreen/White6 Light Blue 15 LightBlue/White7 White/Black8 Red/Black9 Light Green/Black

Page 84: Cross-Reference & Online Spec Sheets - Datasheet Archive

73

Computer Cable Electronics

Multi-Paired, Foil Shield UL2464,NECTypeCMR(UL)c(UL),CSACMG

Product Construction: Conductor: •24AWGfullyannealedstrandedtinned

copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-codedS-RPVC

per UL 1061 •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester

with25%overlap,minimum,foilfacingout

•Strandedtinnedcopperdrainwire

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+80˚C

Applications: •Computers •Industrialequipment •Datatransmission •Controlcircuits •SuitableforEIARS-232applications •Suggestedvoltagerating:300volts

Features: •Superiorshieldingwherenoiserejection

is critical •Assistssystemdesignersinmeeting

FCC Docket 20780 demands

Compliances: •NECArticle800TypeCMR(UL:75°C) •ULStyle2464(UL:80˚C,300V) •CSACMG(CSA,60°C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OF

PAIRSAWGSIZE

COND.STRAND

NOMINAL INSULATION THICKNESS

NOMINAL JACKET

THICKNESSNOMINAL

O.D.NOMINAL DCR

Ω/kft

NOMINAL CAP.*pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

C0600A 1 24 7/32 0.010 0.25 0.032 0.81 0.157 3.99 25.7 7.2 19.7 21.5

C0601A 2 24 7/32 0.010 0.25 0.032 0.81 0.214 5.44 25.7 7.2 28.7 21.5

C0602A 3 24 7/32 0.010 0.25 0.032 0.81 0.225 5.72 25.7 7.2 25.7 21.5

C0603A 4 24 7/32 0.010 0.25 0.032 0.81 0.245 6.23 25.7 7.2 25.7 20.2

C0604A 5 24 7/32 0.010 0.25 0.032 0.81 0.265 6.73 25.7 7.2 25.7 20.2

C0605A 6 24 7/32 0.010 0.25 0.032 0.81 0.287 7.29 25.7 7.2 23.7 42.7

C0606A 7 24 7/32 0.010 0.25 0.032 0.81 0.287 7.29 25.7 7.2 23.7 42.7

C0607A 8 24 7/32 0.010 0.25 0.032 0.81 0.309 7.85 25.7 7.2 23.7 42.7

C0608A 9 24 7/32 0.010 0.25 0.032 0.81 0.331 8.41 25.7 7.2 23.7 42.7

C0609A 10 24 7/32 0.010 0.25 0.032 0.81 0.359 9.12 25.7 7.2 23.7 42.7

C0610A 15 24 7/32 0.010 0.25 0.032 0.81 0.410 10.41 25.7 7.2 23.7 42.7

C0611A 19 24 7/32 0.010 0.25 0.032 0.81 0.432 10.97 25.7 7.2 23.7 42.7

C0612A 25 24 7/32 0.010 0.25 0.032 0.81 0.505 12.84 25.7 7.2 23.7 42.7

C0720A 1 22 7/30 0.010 0.25 0.032 0.81 0.169 4.29 16.6 6.2 40.4 72.6

C0721A 2 22 7/30 0.010 0.25 0.032 0.81 0.234 5.94 16.6 6.2 32.3 58.1

C0722A 3 22 7/30 0.010 0.25 0.032 0.81 0.246 6.25 16.6 6.2 27.8 50.1

C0723A 4 22 7/30 0.010 0.25 0.032 0.81 0.269 6.83 16.6 6.2 27.8 50.1

C0724A 5 22 7/30 0.010 0.25 0.032 0.81 0.292 7.42 16.6 6.2 27.8 50.1

C0725A 6 22 7/30 0.010 0.25 0.032 0.81 0.317 8.05 16.6 6.2 25.5 45.9

C0726A 9 22 7/30 0.010 0.25 0.032 0.81 0.367 9.32 16.6 6.2 25.5 45.9

C0728A 15 22 7/30 0.010 0.25 0.032 0.81 0.457 11.62 16.6 6.2 25.5 45.9

C0729A 19 22 7/30 0.010 0.25 0.032 0.81 0.482 12.24 16.6 6.2 25.5 45.9

C0730A 27 22 7/30 0.010 0.25 0.032 0.81 0.576 14.36 16.6 6.2 26.0 46.0*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFPAIRS COLOR

NO. OFPAIRS COLOR

1 BlackwithRed 14 GreenwithWhite2 BlackwithWhite 15 Green with Blue3 Black with Green 16 Green with Yellow4 Black with Blue 17 Green with Brown5 Black with Yellow 18 Green with Orange6 Black with Brown 19 WhitewithBlue7 Black with Orange 20 WhitewithYellow8 RedwithWhite 21 WhitewithBrown9 RedwithGreen 22 WhitewithOrange

10 RedwithBlue 23 Blue with Yellow11 RedwithYellow 24 Blue with Brown12 RedwithBrown 25 Blue with Orange13 RedwithOrange 26 Brown with Yellow

27 Brown with Orange

Page 85: Cross-Reference & Online Spec Sheets - Datasheet Archive

74

Electronics Computer Cable

Multi-Paired, Foil Shield, Lo-Cap® UL2448,NECTypeCM(UL)c(UL),CMH

Product Construction: Conductor: •24AWGfullyannealedstrandedtinned

copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-coded

polyethylene •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester

with25%overlap,minimum,foilfacingout

•Strandedtinnedcopperdrainwire

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+75°C

Applications: •Computers •Industrialequipment •Datatransmission •Controlcircuits •Suitableforlowcapacitanceapplications •Suggestedvoltagerating:30volts

Compliances: •NECArticle800TypeCM(UL:75˚C) •ULStyle2448(UL:60˚C,30V) •CSACMH(CSA:60˚C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMHFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OF

PAIRSAWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET

THICKNESSNOMINAL

O.D.

NOMINAL DCR Ω/kft

VEL.OF

PROP.,%

NOM.IMP.,Ω

NOMINALCAP.*pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

C0890A 2 24 7/32 0.015 0.38 0.032 0.81 0.247 6.27 25.7 7.20 66 100 14.4 26.0

C0901A 3 24 7/32 0.015 0.38 0.032 0.81 0.261 6.63 25.7 7.20 66 100 13.9 25.1

C0893A 4 24 7/32 0.015 0.38 0.032 0.81 0.277 7.04 25.7 7.20 66 100 13.9 25.1

C0894A 5 24 7/32 0.015 0.38 0.032 0.81 0.310 7.87 25.7 7.20 66 100 13.9 25.1

C0899A 6 24 7/32 0.015 0.38 0.032 0.81 0.336 8.53 25.7 7.20 66 100 13.0 23.4

C0896A 9 24 7/32 0.015 0.38 0.032 0.81 0.391 9.93 25.7 7.20 66 100 13.0 23.4

C0897A 12.5 24 7/32 0.015 0.38 0.032 0.97 0.459 11.66 25.7 7.20 66 100 13.0 23.4

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFPAIRS COLOR

NO. OFPAIRS COLOR

1 BlackpairedwithWhite 7 White/BluepairedwithBlue/White

2 RedpairedwithGreen 8 White/BrownpairedwithBrown/White

3 Brown paired with Blue 9 White/OrangepairedwithOrange/White

4 Orange paired with Yellow 10 White/GreenpairedwithGreen/White

5 VioletpairedwithGray 11 White/RedpairedwithRed/White

6 Tan paired with Pink 12 White/BlackpairedwithBlack/White

SingleConductor:GreenWithYellowStripe

Page 86: Cross-Reference & Online Spec Sheets - Datasheet Archive

75

Computer Cable Electronics

Multi-Paired, Foil/Braid Shield UL2464,NECTypeCMR(UL)c(UL),CSACMG

Product Construction: Conductor: •22and24AWGfullyannealedstranded

tinned copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-codedS-RPVC

per UL 1061 •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester

with25%overlap,minimum,foilfacingout

•65%tinnedcopperbraid

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+80˚C

Applications: •Computers •Industrialequipment •Datatransmission •Controlcircuits •SuitableforEIARS-232applications •Suggestedvoltagerating:300volts

Features: •Braidshieldprovidesgoodflexibility •Superiorshieldingwherenoiserejection

is critical •Assistssystemdesignersinmeeting

FCC Docket 20789 demands

Compliances: •NECArticle800TypeCMR(UL:75˚C) •ULStyle2464(UL:80˚C,300V) •CSACMG(CSA:60˚C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OF

PAIRSAWGSIZE

COND.STRAND

NOMINAL INSULATION THICKNESS

NOMINAL JACKET

THICKNESSNOMINAL

O.D.

NOMINAL DCR Ω/kft

NOMINAL CAP.*pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

C0620A 2 24 7/32 0.010 0.25 0.032 0.81 0.235 5.97 25.7 5.4 29.5 53.0

C0621A 3 24 7/32 0.010 0.25 0.032 0.81 0.231 5.87 25.7 5.0 26.4 47.6

C0622A 4 24 7/32 0.010 0.25 0.032 0.81 0.253 6.43 25.7 4.5 26.4 47.6

C0623A 5 24 7/32 0.010 0.25 0.032 0.81 0.278 7.06 25.7 4.6 26.4 47.6

C0624A 6 24 7/32 0.010 0.25 0.032 0.81 0.296 7.52 25.7 2.9 24.4 43.9

C0625A 7 24 7/32 0.010 0.25 0.032 0.81 0.313 7.95 25.7 3.1 24.4 43.9

C0626A 8 24 7/32 0.010 0.25 0.032 0.81 0.336 8.53 25.7 4.1 24.4 43.9

C0628A 10 24 7/32 0.010 0.25 0.032 0.81 0.357 9.07 25.7 2.6 24.4 43.9

C0630A 12.5 24 7/32 0.010 0.25 0.032 0.81 0.386 9.80 25.7 3.6 24.4 43.9

C0650A 2 22 7/30 0.010 0.25 0.032 0.81 0.229 5.82 16.6 3.8 33.2 59.7

C0651A 3 22 7/30 0.010 0.25 0.032 0.81 0.296 7.52 16.6 4.1 28.6 51.5

C0652A 4 22 7/30 0.010 0.25 0.032 0.81 0.320 8.13 16.6 3.5 28.6 51.5

C0653A 5 22 7/30 0.010 0.25 0.032 0.81 0.331 8.41 16.6 3.9 28.6 51.5

C0654A 6 22 7/30 0.010 0.25 0.032 0.81 0.348 8.84 16.6 4.4 26.2 47.2

C0655A 7 22 7/30 0.010 0.25 0.032 0.81 0.348 8.84 16.6 5.0 26.2 47.2

C0656A 8 22 7/30 0.010 0.25 0.032 0.81 0.368 9.35 16.6 3.8 26.2 47.2

C0658A 10 22 7/30 0.010 0.25 0.032 0.81 0.388 9.86 16.6 4.1 26.2 47.2

C0660A 12.5 22 7/30 0.010 0.25 0.032 0.81 0.429 10.90 16.6 4.7 26.2 47.2

C0663A 25 22 7/30 0.010 0.25 0.058 0.81 0.620 15.75 16.6 2.1 26.2 46.0*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFPAIRS COLOR

NO. OFPAIRS COLOR

1 BlackpairedwithRed 13 RedpairedwithOrange

2 BlackpairedwithWhite 14 WhitepairedwithGreen

3 Black paired with Green 15 Blue paired with Green

4 Black paired with Blue 16 Yellow paired with Green

5 Black paired with Yellow 17 Brown paired with Green

6 Black paired with Brown 18 Orange paired with Green

7 Black paired with Orange 19 WhitepairedwithBlue

8 RedpairedwithWhite 20 WhitepairedwithYellow

9 RedpairedwithGreen 21 WhitepairedwithBrown

10 RedpairedwithBlue 22 WhitepairedwithOrange

11 RedpairedwithYellow 23 Yellow paired with Blue

12 RedpairedwithBrown 24 Blue paired with Brown

25 Orange paired with Blue

SingleConductor:GreenwithYellowStripe

Page 87: Cross-Reference & Online Spec Sheets - Datasheet Archive

76

Electronics Computer Cable

Multi-Paired, Foil/Braid Shield, Lo-Cap® UL2919,NECTypeCM(UL)c(UL)CMH

Product Construction: Conductor: •24AWGfullyannealedstrandedtinned

copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-coded

polyethylene •Colorcode:Seechartsbelow

Shield: •100%Flexfoil® aluminum/polyester with

25%overlap,minimum,foilfacingout •Strandedtinnedcopperdrainwire •90%tinnedcopperbraid

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+80˚C

Applications: •Computers •Industrialequipment •Datatransmission •Controlcircuits •Lowcapacitancerequirements •SuitableforEIARS-485applications •Suggestedvoltagerating:30volts

Features: •Braidshieldprovidesgoodflexibility •Superiorshieldingwherenoiserejection

is critical •Assistssystemdesignersinmeeting

FCC Docket 20789 demands

Compliances: •NECArticle800TypeCM/CMH

(UL:75°C) •ULStyle2919(UL:80˚C,30V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMHFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OF

PAIRSAWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET

THICKNESSNOMINAL

O.D.

NOMINAL DCR Ω/kft

VEL.OF

PROP.,%

NOM.IMP.,Ω

NOMINALCAP.*pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

C0841A 1 24 7/32 0.024 0.61 0.032 0.81 0.235 5.97 25.7 2.9 66 120 14.6 26.2

C0842A 2 24 7/32 0.024 0.61 0.032 0.81 0.304 7.72 25.7 2.3 66 120 11.7 21.0

C0843A 3 24 7/32 0.024 0.61 0.032 0.81 0.360 9.14 25.7 2.3 66 120 11.9 21.4

C0844A 4 24 7/32 0.024 0.61 0.032 0.81 0.390 9.91 25.7 2.1 66 120 11.9 21.4

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code Chart 1NO. OFPAIRS COLOR

1 BlackpairedwithRed

2 BlackpairedwithWhite

3 Black paired with Green

4 Black paired with Blue

Color Code Chart 2NO. OFPAIRS COLOR

NO. OFPAIRS COLOR

1 White–BlueStripeBlue–WhiteStripe 3 White–GreenStripe

Green–WhiteStripe

2 White–OrangeStripeOrange–WhiteStripe 4 White–BrownStripe

Brown–WhiteStripe

CATALOG NUMBER

NO. OF

PAIRSAWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET

THICKNESSNOMINAL

O.D.

NOMINAL DCR Ω/kft

VEL.OF

PROP.,%

NOM.IMP.,Ω

NOMINALCAP.*pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

C4841A 1 24 7/32 0.024 0.61 0.032 0.81 0.235 5.97 25.7 2.9 66 120 14.6 26.2

C4842A 2 24 7/32 0.024 0.61 0.032 0.81 0.304 7.72 25.7 2.3 66 120 11.7 21.0

C4843A 3 24 7/32 0.024 0.61 0.032 0.81 0.360 9.14 25.7 2.3 66 120 11.9 21.4

C4844A 4 24 7/32 0.024 0.61 0.032 0.81 0.390 9.91 25.7 2.1 66 120 11.9 21.4

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Page 88: Cross-Reference & Online Spec Sheets - Datasheet Archive

77

Computer Cable Electronics

Multi-Paired, Foil/Braid Shield, Lo-Cap® UL2919,NECTypeCM(UL)c(UL)CMH

Product Construction: Conductor: •24AWGfullyannealedstrandedtinned

copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-coded

polyethylene •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester

with25%overlap,minimum,foilfacingout

•Strandedtinnedcopperdrainwire •90%tinnedcopperbraid

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+80˚C

Applications: •Computers •Industrialequipment •Datatransmission •Controlcircuits •Lowcapacitancerequirements •SuitableforEIARS-232applications •SuitableforEIARS-422applications •Suggestedvoltagerating:30volts

Features: •Braidshieldprovidesgoodflexibility •Superiorshieldingwherenoiserejection

is critical •Assistssystemdesignersinmeeting

FCC Docket 20789 demands

Compliances: •NECArticle800TypeCM/CMH

(UL:75˚C) •ULStyle2919(UL:80˚C,30V) •CSACMH(CSA:60˚C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMHFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OF

PAIRSAWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET

THICKNESSNOMINAL

O.D.

NOMINAL DCR Ω/kft

VEL.OF

PROP.,%

NOM.IMP.,Ω

NOMINALCAP.*pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

C0829A 2 24 7/32 0.015 0.38 0.032 0.81 0.257 6.53 25.7 2.7 66 100 14.8 26.7

C0830A 3 24 7/32 0.015 0.38 0.032 0.81 0.289 7.34 25.7 2.6 66 100 14.2 25.5

C0831A 4 24 7/32 0.015 0.38 0.032 0.81 0.313 7.95 25.7 3.2 66 100 14.2 25.5

C0832A 5 24 7/32 0.015 0.38 0.032 0.81 0.338 8.59 25.7 1.9 66 100 14.2 25.5

C0839A 6 24 7/32 0.015 0.38 0.032 0.81 0.364 9.24 25.7 2.4 66 100 13.2 23.8

C0833A 7 24 7/32 0.015 0.38 0.032 0.81 0.364 9.24 25.7 2.0 66 100 13.2 23.8

C0835A 10 24 7/32 0.015 0.38 0.038 0.97 0.462 11.73 25.7 1.7 66 100 13.2 23.8

C0836A 12 24 7/32 0.015 0.38 0.038 0.97 0.479 12.17 25.7 1.8 66 100 13.2 23.8

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFCOND. COLOR

NO. OFCOND. COLOR

1 BlackpairedwithRed 7 Black paired with Orange

2 BlackpairedwithWhite 8 RedpairedwithWhite

3 Black paired with Green 9 RedpairedwithGreen

4 Black paired with Blue 10 RedpairedwithBlue

5 Black paired with Yellow 11 RedpairedwithYellow

6 Black paired with Brown 12 RedpairedwithBrown

Page 89: Cross-Reference & Online Spec Sheets - Datasheet Archive

78

Electronics Computer Cable

Multi-Paired, Foil/Braid Shield, Lo-Cap® UL2919,NECTypeCM(UL)c(UL)CMH

Product Construction: Conductor: •24AWGfullyannealedstrandedtinned

copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-codedLo-Cap®

foamed polypropylene •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester with

25%overlap,minimum,foilfacingout •Strandedtinnedcopperdrainwire •65%tinnedcopperbraid

Jacket: •PVC,gray •Temperaturerange:-20°Cto+80°C

Applications: •High-speedcomputerinterconnects •CAD/CAMsystems •EIARS-232andRS-423systems •Controlcircuits •Industrialequipment •Lowsignaldistortiondatarequirements •Suggestedvoltagerating:30volts

Features: •Braidshieldprovidesgoodflexibility •Superiorshieldingwherenoiserejection

is critical •Assistssystemdesignersinmeeting

FCC Docket 20789 demands

Compliances: •NECArticle800TypeCM/CMH

(UL:75°C) •ULStyle2919(UL:80°C,30V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Color Code ChartNO. OFPAIRS COLOR

NO. OFPAIRS COLOR

NO. OFPAIRS COLOR

1 White–BlueStripeBlue–WhiteStripe 10 Red–GrayStripe

Gray–RedStripe 18Yellow–Green StripeGreen–Yellow Stripe

2 White–OrangeStripeOrange–WhiteStripe 11 Black–Blue Stripe

Blue–Black Stripe 19Yellow–Brown StripeBrown–Yellow Stripe

3 White–GreenStripeGreen–WhiteStripe 12 Black–Orange Stripe

Orange–Black Stripe 20Yellow–Gray StripeGray–Yellow Stripe

4 White–BrownStripeBrown–WhiteStripe 13 Black–Green Stripe

Green–Black Stripe 21Violet–BlueStripeBlue–VioletStripe

5 White–GrayStripeGray–WhiteStripe 14 Black–Brown Stripe

Brown–Black Stripe 22Violet–OrangeStripeOrange–VioletStripe

6 Red–BlueStripeBlue–RedStripe 15 Black–Gray Stripe

Gray–Black Stripe 23Violet–GreenStripeGreen–VioletStripe

7 Red–OrangeStripeOrange–RedStripe 16 Yellow–Blue Stripe

Blue–Yellow Stripe 24Violet–BrownStripeBrown–VioletStripe

8 Red–GreenStripeGreen–RedStripe 17 Yellow–Orange Stripe

Orange–Yellow Stripe 25Violet–GrayStripeGray–VioletStripe

9 Red–BrownStripeBrown–RedStripe

SingleConductor:GreenwithYellowStripe

CATALOG NUMBER

NO. OF

PAIRSAWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET

THICKNESSNOMINAL

O.D.

NOMINAL DCR Ω/kft

VEL.OF

PROP.,%

NOM.IMP.,Ω

NOMINALCAP.*pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

C0515A 2 24 7/32 0.016 0.41 0.032 0.81 0.276 7.01 25.7 3.0 78 132 10.2 18.4

C0516A 3 24 7/32 0.016 0.41 0.032 0.81 0.290 7.37 25.7 3.2 78 132 9.9 17.8

C0517A 4 24 7/32 0.016 0.41 0.032 0.81 0.315 8.00 25.7 3.3 78 132 9.9 17.8

C0518A 5 24 7/32 0.016 0.41 0.032 0.81 0.340 8.64 25.7 4.2 78 132 9.9 17.8

C0519A 6 24 7/32 0.016 0.41 0.032 0.81 0.368 9.35 25.7 3.6 78 141 9.2 16.6

C0520A 7 24 7/32 0.016 0.41 0.032 0.81 0.370 9.40 25.7 3.5 78 141 9.2 16.6

C0521A 8 24 7/32 0.016 0.41 0.032 0.81 0.397 10.08 25.7 2.7 78 141 9.2 16.6

C0522A 10 24 7/32 0.016 0.41 0.038 0.97 0.473 12.01 25.7 2.4 78 141 9.2 16.6

C0523A 12.5 24 7/32 0.016 0.41 0.038 0.97 0.486 12.34 25.7 2.4 78 141 9.2 16.6

C0524A 15 24 7/32 0.016 0.41 0.048 1.22 0.555 14.10 25.7 2.6 78 141 9.2 16.6

C0525A 18 24 7/32 0.016 0.41 0.048 1.22 0.585 14.86 25.7 2.1 78 141 9.2 16.6

C0526A 25 24 7/32 0.016 0.41 0.048 1.22 0.677 17.20 25.7 2.0 78 141 9.2 16.6

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Page 90: Cross-Reference & Online Spec Sheets - Datasheet Archive

79

Computer Cable Electronics

Multi-Paired, Foil/Braid Shield, Lo-Cap® UL 2960, NEC Type CL2

Product Construction: Conductor: •28AWGfullyannealedstrandedtinned

copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-coded

polypropylene •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester with

25%overlap,minimum,foilfacingout •Strandedtinnedcopperdrainwire •90%tinnedcopperbraid

Jacket: •PVC,gray •Temperaturerange:-20°Cto+75°C

Applications: •Computers •Industrialequipment •Datatransmission •Controlcircuits •Lowcapacitancerequirements •SuitableforEIARS-232applications •SuitableforEIARS-422applications •Suggestedvoltagerating:30volts

Features: •Braidshieldprovidesgoodflexibility •Superiorshieldingwherenoiserejection

is critical •Assistssystemdesignersinmeeting

FCC Docket 20789 demands

Compliances: •NECArticle725TypeCL2(UL:75°C) •ULStyle2960(UL:60°C,30V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Color Code ChartNO. OFCOND. COLOR

NO. OFCOND. COLOR

1 BlackpairedwithRed 7 Black paired with Orange

2 BlackpairedwithWhite 8 RedpairedwithWhite

3 Black paired with Gren 9 RedpairedwithGreen

4 Black paired with Blue 10 RedpairedwithBlue

5 Black paired with Yellow 11 RedpairedwithYellow

6 Black paired with Brown 12 RedpairedwithBrown

CATALOG NUMBER

NO. OF

PAIRSAWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET

THICKNESSNOMINAL

O.D.

NOMINAL DCR Ω/kft

VEL.OF

PROP.,%

NOM.IMP.,Ω

NOMINALCAP.*pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

C0804A 2 28 7/36 0.009 0.23 0.032 0.81 0.194 4.93 67.5 4.0 66 100 14.8 26.6

C0805A 3 28 7/36 0.009 0.23 0.032 0.81 0.194 4.93 67.5 4.2 66 100 14.0 25.3

C0806A 4 28 7/36 0.009 0.23 0.032 0.81 0.211 5.36 67.5 3.3 66 100 14.0 25.3

C0807A 5 28 7/36 0.009 0.23 0.032 0.81 0.226 5.74 67.5 3.5 66 100 14.0 25.3

C0808A 7 28 7/36 0.009 0.23 0.032 0.81 0.253 6.43 67.5 2.9 66 100 13.1 23.5

C0809A 9 28 7/36 0.009 0.23 0.032 0.81 0.286 7.26 67.5 2.9 66 100 13.1 23.5

C0810A 10 28 7/36 0.009 0.23 0.032 0.81 0.285 7.24 67.5 2.9 66 100 13.1 23.5

C0812A 12 28 7/36 0.009 0.23 0.032 0.81 0.294 7.47 67.5 3.3 66 100 13.1 23.5

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Page 91: Cross-Reference & Online Spec Sheets - Datasheet Archive

80

Electronics Computer Cable

Multi-Paired, Individually Foil Shielded NECTypeCL2andCM(UL)c(UL)

Product Construction: Conductor: •20AWGfullyannealedstrandedtinned

copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,color-coded

polypropylene •Colorcode:Seechartbelow

Shield: •Individuallyshieldedpairs •100%Flexfoil® aluminum/polyester with

25%overlap,minimum,foilfacingin •Strandedtinnedcopperdrainwireeach

pair

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+75°C

Applications: •Applicationsfortotalisolationofsignal •Computers •Controlcircuits •Industrialequipment •Suggestedvoltagerating:300volts

Features: •Individuallyshieldedpairsforexcellent

signal isolation •Excellenthighfrequencyproperties •Mechanicaldurability

Compliances: •NECArticle725TypeCL2(UL:75°C,

150V) •NECArticle800TypeCM(UL:75°C,

300V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Color Code ChartNO. OFPAIRS COLOR

1 RedpairedwithWhite/Red

2 BlackpairedwithWhite/Black

3 GreenpairedwithWhite/Green

4 WhitepairedwithWhite/Yellow

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C1368A 4 20 7/28 0.015 0.38 0.032 0.81 0.364 9.25 23.0 41.5

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Page 92: Cross-Reference & Online Spec Sheets - Datasheet Archive

81

Computer Cable Electronics

Multi-Paired, Individually Foil Shielded UL2464,NECTypeCM(UL)c(UL),CSACMG

Product Construction: Conductor: •22AWGfullyannealedsolidtinned

copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-codedPVC •Colorcode:Seechartbelow

Shield: •Individuallyshieldedpairs •100%Flexfoil® aluminum/polyester with

25%overlap,minimum,foilfacingin •Solidtinnedcopperdrainwireeachpair

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+80˚C

Applications: •Applicationsfortotalisolationofsignal •Computers •Controlcircuits •Industrialequipment •Suggestedvoltagerating:300volts

Features: •Individuallyshieldedpairsforexcellent

signal isolation •Excellenthigh-frequencyproperties •Mechanicaldurability

Compliances: •NECArticle800TypeCM(UL:75˚C) •ULStyle2464(UL:80˚C,300V) •CSACMG(CSA:60˚C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMGFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET

THICKNESSNOMINAL

O.D.

NOMINAL DCR Ω/kft

NOMINAL IMPEDANCE

Ω

NOMINALCAP.*pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

C6035A 3 22 Solid 0.015 0.38 0.032 0.81 0.304 7.72 16.5 11.3 50 38.6 69.4

C6036A 6 22 Solid 0.015 0.38 0.032 0.81 0.397 10.08 16.5 11.3 50 38.6 69.4

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFPAIRS COLOR

NO. OFPAIRS COLOR

1 BlackpairedwithRed 4 Black paired with Blue

2 BlackpairedwithWhite 5 Black paired with Yellow

3 Black paired with Green 6 Black paired with Brown

Page 93: Cross-Reference & Online Spec Sheets - Datasheet Archive

82

Electronics Computer Cable

Multi-Paired, Individually Foil Shielded UL2919,NECTypeCM,CSACMH

Product Construction: Conductor: •24thru18AWGfullyannealedstranded

tinned copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,color-coded

polyethylene •Colorcode:Seechartbelow

Shield: •Individuallyshieldedpairs •100%Flexfoil® aluminum/polyester with

25%overlap,minimum,foilfacingin •Strandedtinnedcopperdrainwireeach

pair

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+80˚C

Applications: •Applicationsfortotalisolationofsignal •Computers •Controlcircuits •Industrialequipment •Suggestedvoltagerating:30volts

Features: •Individuallyshieldedpairsforexcellent

signal isolation •Excellenthighfrequencyproperties •Mechanicaldurability

Compliances: •NECArticle800TypeCM(UL:75°C) •ULStyle2919(UL:80˚C,30V) •CSACMH(CSA:60˚C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest •PassesCSACMHFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET

THICKNESSNOMINAL

O.D.

NOMINAL DCR Ω/kft

VEL.OF

PROP.,%

NOM.IMP.,Ω

NOMINALCAP.**pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

C6065A 3 24 7/32 0.011 0.28 0.032 0.81 0.269 6.83 26.0 18.0 66 71 21.7 39.0

C6066A 6 24 7/32 0.011 0.28 0.032 0.81 0.349 8.86 26.0 18.0 66 71 21.7 39.0

C6067A 9 24 7/32 0.011 0.28 0.032 0.81 0.406 10.31 26.0 18.0 66 71 21.7 39.0

C6040A 3 22 7/30 0.011 0.28 0.032 0.81 0.292 7.42 16.5 11.3 66 63 24.4 43.9

C6041A 6 22 7/30 0.011 0.28 0.032 0.81 0.381 9.68 16.5 11.3 66 63 24.4 43.9

C6042A 9 22 7/30 0.011 0.28 0.032 0.81 0.445 11.30 16.5 11.3 66 63 24.4 43.9

C6043A 11 22 7/30 0.011 0.28 0.032 0.81 0.486 12.34 16.5 11.3 66 63 24.4 43.9

C6059A 12 22 7/30 0.011 0.28 0.048 1.22 0.533 13.54 16.5 11.3 66 63 24.4 43.9

C6044A 15 22 7/30 0.011 0.28 0.048 1.22 0.591 15.01 16.5 11.3 66 63 24.4 43.9

C6060A 17 22 7/30 0.011 0.28 0.048 1.22 0.622 15.80 16.5 11.3 66 63 24.4 43.9

C6045A 19 22 7/30 0.011 0.28 0.048 1.22 0.622 15.80 16.5 11.3 66 63 24.4 43.9

C6046A* 27 22 7/30 0.011 0.28 0.048 1.22 0.696 17.68 16.5 11.3 66 63 24.4 43.9

C6052A 3 20 7/28 0.013 0.33 0.032 0.81 0.339 8.61 10.5 10.2 66 61 25.3 45.6

C6053A 6 20 7/28 0.013 0.33 0.032 0.81 0.446 11.33 10.5 10.2 66 61 25.3 45.6

C6054A 9 20 7/28 0.013 0.33 0.048 1.22 0.555 14.10 10.5 10.2 66 61 25.3 45.6

C6056A 12 20 7/28 0.013 0.33 0.048 1.22 0.623 15.82 10.5 10.2 66 61 25.3 45.6

C6058A 15 20 7/28 0.013 0.33 0.048 1.22 0.692 17.58 10.5 10.2 66 61 25.3 45.6

C6047A 3 18 16/30 0.016 0.41 0.032 0.81 0.395 10.03 7.2 8.3 66 60 25.7 46.2

C6048A 6 18 16/30 0.016 0.41 0.048 1.22 0.556 14.12 7.2 8.3 66 60 25.7 46.2

C6049A 9 18 16/30 0.016 0.41 0.048 1.22 0.649 16.48 7.2 8.3 66 60 25.7 46.2

C6050A 12 18 16/30 0.016 0.41 0.048 1.22 0.731 18.57 7.2 8.3 66 60 25.7 46.2

C6051A 15 18 16/30 0.016 0.41 0.048 1.22 0.776 19.71 7.2 8.3 66 60 25.7 46.2*UL2919,CSACMHOnly**A – Capacitance between conductors**B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFPAIRS COLOR

NO. OFPAIRS COLOR

NO. OFPAIRS COLOR

1 BlackpairedwithRed 10 RedpairedwithBlue 19 WhitepairedwithBlue

2 BlackpairedwithWhite 11 RedpairedwithYellow 20 WhitepairedwithYellow

3 Black paired with Green 12 RedpairedwithBrown 21 WhitepairedwithBrown

4 Black paired with Blue 13 RedpairedwithOrange 22 WhitepairedwithOrange

5 Black paired with Yellow 14 GreenpairedwithWhite 23 Blue paired with Yellow

6 Black paired with Brown 15 Green paired with Blue 24 Blue paired with Brown

7 Black paired with Orange 16 Green paired with Yellow 25 Blue paired with Orange

8 RedpairedwithWhite 17 Green paired with Brown 26 Brown paired with Yellow

9 RedpairedwithGreen 18 Green paired with Orange 27 Brown paired with Orange

Page 94: Cross-Reference & Online Spec Sheets - Datasheet Archive

83

Computer Cable Electronics

Multi-Paired, Individually Foil Shielded, Lo-Cap® UL2493,NECTypeCM(UL)c(UL)CMH

Product Construction: Conductor: •24AWGfullyannealedstrandedtinned

copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-codedfoamed

Lo-Cap® polypropylene •Colorcode:Seechartbelow

Shield: •Individuallyshieldedpairs •100%Flexfoil® aluminum/polyester with

25%overlap,minimum,foilfacingin •Strandedtinnedcopperdrainwireeach

pair

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+75˚C

Applications: •High-speedcomputers •Industrialequipment •Controlcircuits •Suitableforlowcapacitanceapplications •SuitableforEIARS-422CAD/CAM

applications •Suggestedvoltagerating:300volts

Features: •Individuallyshieldedpairsforexcellent

signal isolation •Excellenthigh-frequencyproperties •Mechanicaldurability

Compliances: •NECArticle800TypeCM/CMH

(UL:75˚C,300V) •ULStyle2493(UL:60˚C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OF

PAIRSAWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET

THICKNESSNOMINAL

O.D.

NOMINAL DCR Ω/kft

VEL.OF

PROP.,%

NOM.IMP.,Ω

NOMINALCAP.*pF/ft

INCHES mm INCHES mm INCHES mm COND. SHLD. A B

C0910A 2 24 7/32 0.022 0.56 0.047 1.19 0.283 7.19 26.0 18.0 78 100 14.8 26.7

C0911A 3 24 7/32 0.022 0.56 0.048 1.22 0.381 9.68 26.0 18.0 78 100 14.8 26.7

C0912A 4 24 7/32 0.022 0.56 0.048 1.22 0.416 10.57 26.0 18.0 78 100 14.8 26.7

C0913A 6 24 7/32 0.022 0.56 0.048 1.22 0.492 12.50 26.0 18.0 78 100 14.8 26.7

C0914A 9 24 7/32 0.022 0.56 0.063 1.60 0.601 15.27 26.0 18.0 78 100 14.8 26.7

C0915A 11 24 7/32 0.022 0.56 0.063 1.60 0.652 16.56 26.0 18.0 78 100 14.8 26.7

C0916A 12 24 7/32 0.022 0.56 0.063 1.60 0.672 17.08 26.0 18.0 78 100 14.8 26.7

C0917A 15 24 7/32 0.022 0.56 0.063 1.60 0.743 18.87 26.0 18.0 78 100 14.8 26.7

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFPAIRS COLOR

NO. OFPAIRS COLOR

1 BlackpairedwithRed 9 RedpairedwithGreen

2 BlackpairedwithWhite 10 RedpairedwithBlue

3 Black paired with Green 11 RedpairedwithYellow

4 Black paired with Blue 12 RedpairedwithBrown

5 Black paired with Yellow 13 RedpairedwithOrange

6 Black paired with Brown 14 GreenpairedwithWhite

7 Black paired with Orange 15 Green paired with Blue

8 RedpairedwithWhite

Page 95: Cross-Reference & Online Spec Sheets - Datasheet Archive

84

Electronics Computer Cable

Multi-Paired, Individually Foil/Braid Shielded, Lo-Cap® UL2493,NECTypeCM(UL)c(UL)CMH

Product Construction: Conductor: •24AWGfullyannealedstrandedtinned

copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-codedfoamed

Lo-Cap® polypropylene •Colorcode:Seechartbelow

Shield: •Individuallyshieldedpairs •100%Flexfoil® aluminum/polyester with

25%overlap,minimum,foilfacingin •Strandedtinnedcopperdrainwire,each

pair •70%tinnedcopperbraid,eachpair

Jacket: •PVC,gray •Temperaturerange:-20˚Cto+75˚C

Applications: •High-speedcomputers •Industrialequipment •Controlcircuits •Designedforlowcapacitance

applications •SuitableforRS-422CAD/CAM

applications •Suggestedvoltagerating:300volts

Features: •Individuallyshieldedpairsforexcellent

signal isolation •Excellenthigh-frequencyproperties •Mechanicaldurability

Compliances: •NECArticle800TypeCM/CMH

(UL:75˚C,300V) •ULStyle2493(UL:60˚C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

VerticalTrayFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Color Code ChartNO. OFPAIRS COLOR

2 BlackpairedwithWhite

3 Black paired with Green

4 Black paired with Blue

CATALOG NUMBER

NO. OF

PAIRSAWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET

THICKNESSNOMINAL

O.D.

NOMINAL DCR** Ω/kft

VEL.OF

PROP.,%

NOM.IMP.,Ω

NOMINALCAP.*pF/ft

INCHES mm INCHES mm INCHES mm C D E A B

C0924A 2 24 7/32 0.022 0.56 0.048 1.22 0.392 9.96 26.0 18.0 4.3 78 100 14.8 26.7

C0925A 3 24 7/32 0.022 0.56 0.048 1.22 0.410 10.41 26.0 18.0 4.4 78 100 14.8 26.7

C0926A 4 24 7/32 0.022 0.56 0.048 1.22 0.445 11.30 26.0 18.0 3.2 78 100 14.8 26.7

*A – Capacitance between conductors *B – Capacitance between one conductor and other conductors connected to shield**C – Conductor resistance**D – Individual shield resistance**E – Overall shield resistance

Page 96: Cross-Reference & Online Spec Sheets - Datasheet Archive

85

Electronics

Coaxial Cable 5

Index Page

Coaxial Solutions Guide 86-87

RG 6/U Type 88-93

RG 8/U Type 94-95

RG 11/U Type 96-99

RG 58/U Type 100

RG 59/U Type 101-108

RG 62/U Type 109

RG 174/U Type 110

RG 213/U Type 111

Twinaxial Cables 112

To meet the needs of today’s sophisticated, high-speed, wide bandwidth electronics over long distances, with minimum signal loss or degradation, General Cable Carol® Brand offers a wide range of coaxial and twinaxial designs in both unbalanced arrays and precision-balanced pairs. This offers the system designer a wide choice of cost-effective products that reflect the most recent changes in the standards set by UL, CSA and/ or the FCC.

Included in this section are recommended Carol® Brand coaxial products for the CATV market. However, these constructions may differ in certain parts of the country.

Unlike other products in the electronic market, coaxial cable does not have one accepted standard construction.

General Cable recommends, in order to avoid installing an unacceptable coaxial cable for the CATV application in your area, the local CATV company should be consulted.

General Cable’s Carol® Brand product mix encompasses standard RG/U-type coaxial constructions in the more popular 50, 75 and 93 ohm designs and miniature coaxial products for smaller high-speed applications.

The twinaxial products meet or exceed the stringent demands of today’s precision- balanced pair systems. The minimization of capacitance unbalance is a necessary requirement for long distance data transmission.

Page 97: Cross-Reference & Online Spec Sheets - Datasheet Archive

86

CATV/MATV/DBS RG 59, RG 6 and RG 11 Ratings

Coax Solution Carol Belden Genesis West Penn Commscope

RG 6 CCS/Foil/60% AL Braid CATV/CM C5775 9116/1829A 5303 841 5726

RG 6 CCS/Foil/60% AL Braid CATVR/CMR C5886 9116R — — —

RG 6 CCS/Quad/Foil/60%/40% AL Braid CATV/CM C5785 1189A 5307 Q841 5740

RG 6 CCS/Quad/Foil/60%/40% AL Braid CATVR/CMR C5889 1884A — — —

RG 6 CCS/Foil/60% AL Braid CMP - Plenum C3524 9116P — 25841 2275K

RG 6 CCS/Quad/Foil/60%/40% AL Braid CMP - Plenum C3525 1189AP — 25Q841 —

RG 11 CCS/Foil/60% AL Braid CATV/CM C5039 1525A — — 5913

RG 11 CCS/Foil/60% AL Braid CL2P/CMP - Plenum C3528 1523AP — — 2285K

*Note: DuPont™ trademark

General Cable offers a complete line of Carol® Brand Coaxial Cables for today’s sophisticated high-speed, wide-bandwidth electronics products that run over long distances with minimal signal loss or degradation.

General Cable has the right coaxial cable to serve every application, including:

• CATV/MATV/DBS

• HDTV/SDI

• CCTV

The General Cable Coaxial Cable Solutions Guide is a quick-reference tool to make it easier to specify and sell the right cable for the required application–residential, commercial, entertainment and security. Whatever the application calls for, we have a coaxial cable that delivers the performance your customers need.

Broadband signal, 5MHz–3GHz, VHF/UHF, is traditionally transmitted as an analog signal received directly off air (MATV) or delivered as a community access television (CATV) service and uses a 75 Ohm system.

Recommended Coaxial Cable Construction: Copper clad steel (CCS) conductor with a foam polyethylene or Teflon* core, an aluminum/Mylar* foil, a minimum of 60% braid, which is typically aluminum (AL) for this application, and a PVC jacket.

For home use, a CM rated coax should be used. A commercial application may require a National Electrical Code (NEC 800 or 725) Riser (CMR) or Plenum (CMP) rated cable. Economical cable solutions use low smoke PVC (75˚C) jackets. Teflon* (FEP) and other fluoropolymer materials (150˚C) may be used to provide a more durable and higher-temperature cable alternative.

It is a common misconception that RG 6 coax is “better” than RG 59. While RG 6 has become the industry standard and is an excellent value, it is a larger cable than RG 59. RG 6 allows the same signal level to be delivered a greater distance. This is expressed as a decibel value at particular frequencies. For example, at 100 MHz, General Cable’s Carol® Brand part number C5775 RG 6 coax cable has an attenuation value of 2.05 db/100'. A similar construction Carol® Brand part number C5782 RG 59 coax cable exhibits an attenuation value (loss) at 100 MHz frequency of 2.70db/100'. This may or may not be significant, depending on the input signal level and distance of the cable run.

For a longer cable run, or if the coax cable is planned for use as the backbone in a system, Carol® Brand part number C5039 RG 11 coax cable should be used, because its attenuation at 100 MHz frequency is 1.30 db/100'.

CATV/MATV/DBS

Coaxial CableSolutions Guide

Page 98: Cross-Reference & Online Spec Sheets - Datasheet Archive

87

HDTV/SDI—Interconnect Cables RG 59, RG 6 and RG 11 Ratings

Coax Solution Carol Belden Genesis West Penn Commscope

RG 59 SBC/Foil/95% TC Braid CMR 395025 1505A 5361 819 5553

RG 59 SBC/Foil/95% TC Braid CMP - Plenum 495023 1506A — — —

RG 6 SBC/Foil/95% TC Braid CMR 395011 1694A — — 5765

RG 6 SBC/Foil/95% TC Braid CMP - Plenum 495025 1695A — — —

RG 11 SBC/Foil/95% TC Braid CMR 395029 7731A — — —

RG 11 SBC/Foil/95% TC Braid CMP - Plenum 495027 7732A — — 2286K

HDTV/SDI A DTV signal is a television signal provided in a digital form. Data bits, like in a computer, provide a dramatically better picture and better sound quality called High Definition TV (HDTV). HDTV is the highest quality of DTV and is only one of the available formats. In addition to enhanced picture quality, the DTV signal allows several program streams (multicasting) on one channel, providing more program potential, as well as interactive services.

Serial Digital Interface (SDI) is the standard for digital video transmission over coaxial cable. The SMPTE 295M standard provides maximum distances (300 meters; 140 meters for High Definition), typically at 270 Mbps with 540 Mbps possible over a coaxial cable.

Recommended Coax Cable Construction: Cable providing signal to and within the home/building will continue to be CCS construction (C5775, C5785). Cables with SBC conductors (395011, 495025) are recommended for the interconnect between the decoder box and other electronic devices (TV, DVD, DVR, CD, Bluray).

CCTV RG 59 and RG 11 Ratings

Coax Solution Carol Belden Genesis West Penn Commscope

RG 59 SBC/95% BC Braid CM C1142 543945 5001 — —

RG 59 Stranded (7/30) BC/95% BC Braid CM C1103 9259 — — —

RG 59 Stranded (7/30) BC/95% BC Braid + 22 AWG (7/30)Shielded Pair CM C8025 9265 — — —

RG 59 SBC/95% BC Braid + 18 AWG (7/26)Unshielded Pair CM C8028 549945 — — —

RG 59 SBC/95% BC Braid + 18 AWG (7/26)Unshielded Pair CMP - Plenum C8030 649948 — — —

RG 59 SBC/95% BC Braid CMP - Plenum 495028 643948 5351 25815 2037V

RG 11 SBC/95% BC Braid CM 395058 513945 — 811 5905

RG 11 SBC/95% BC Braid CMP - Plenum 495015 613948 — — 2286K

RG 6 BC/95% BC Braid CMP - Plenum 495035 — — — 2277V

CCTV Closed Circuit TV (CCTV) signals are typically lower-frequency analog signals. Attenuation increases as frequency increases, therefore lower baseband signals are able to travel longer distances on an RG 59 type coaxial cable than a higher-frequency television signal. This is why RG 59 is the most common coax for CCTV. It is becoming more common for Unshielded Twisted Pair (UTP) products, like Category 5e and 6 cables, to be used for Closed Circuit over Twisted Pair (CCTP) or Web-enabled cameras implemented over a Power over Ethernet network architecture; however, these solutions require the use of specialized equipment.

Recommended Coax Cable Construction: Solid bare copper (SBC) conductor and a bare copper (BC) braid shield with coverage of 90-95% to minimize signal loss of both the horizontal and vertical sync signals. Stranded conductors are recommended for pan, zoom, tilt (PZT) cameras.

*Abbreviation Key AL - aluminum SBC - solid bare copper CCS- copper clad steel BC - bare copper TC - tinned copper

Page 99: Cross-Reference & Online Spec Sheets - Datasheet Archive

88

Electronics Coaxial Cable

RG 6/U Type

Product Construction: Conductors: •CopperperASTMB-3 •Copper-cladsteelperASTMB-869

Insulation/Core: •Foampolyethylene(PE)design

Shield: •Barecopperoraluminumbraid •Flexfoil® shield

Jacket: •PremiumPVCcompound

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •SuitableforRFsignaltransmission •MATV •CATV •CCTV† •HDTV •Digitalvideo •Dropcable •FMbroadcast •SeeCoaxConnectorCrossReference,

pages 192-199

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

C5760RG 6/U Type

18 Ga.Solid

Copper-Clad Steel

28.9 Ω/Mft.

Foam PE100% Flexfoil®

30 Ga. CCSSpiral Served

Shield30.0 Ω/Mft.

Black PVC16.20 53.15 82 75 1

1050

100200500

1000

0.260.811.462.052.834.536.59

0.180 4.57 0.240 6.10

C5761†RG 6/U TypeUL CL2, CATV, CMc(UL) CM

18 Ga.Solid Bare

Copper6.5 Ω/Mft.

Foam PE100% Flexfoil®

+95%Bare Copper

Braid2.6 Ω/Mft.

Black PVC16.20 53.15 83 75 1

1050

100200500

1000

0.260.811.462.052.834.536.59

0.180 4.57 0.275 6.98

C5775RG 6/U TypeUL CL2, CATV, CMc(UL) CM

18 Ga.Solid

Copper-Clad Steel

28.9 Ω/Mft.

Foam PE100% Flexfoil®

Bonded+60%

Aluminum Braid9.0 Ω/Mft.

Black PVC16.20 53.15 83 75 1

1050

100200500

10001450180022003000

0.260.811.462.052.834.536.598.108.80

10.1011.79

0.180 4.57 0.275 6.98

C5886RG 6/U TypeRiserUL CL2R, CATVR, CMRc(UL) CMR

18 Ga.Solid

Copper-Clad Steel

28.9 Ω/Mft.

Foam PE100% Flexfoil®

Bonded+60%

Aluminum Braid9.0 Ω/Mft.

Black PVC16.20 53.15 83 75 1

1050

100200500

10001450180022003000

0.260.811.462.052.834.536.598.108.80

10.1011.79

0.180 4.57 0.275 6.98

C5776RG 6/U TypeUL CL2, CATV, CMc(UL) CM

18 Ga.Solid

Copper-Clad Steel

28.9 Ω/Mft.

Foam PE100% Flexfoil®

Bonded+95%

Aluminum Braid10.5 Ω/Mft.

Black PVC16.20 53.15 83 75 1

1050

100200500

10001450180022003000

0.260.811.462.052.834.536.598.108.80

10.1011.79

0.180 4.57 0.275 6.98

Page 100: Cross-Reference & Online Spec Sheets - Datasheet Archive

89

Coaxial Cable Electronics

RG 6/U Type

Product Construction: Conductors: •Copper-cladsteelperASTMB-869

Insulation/Core: •Solidandfoampolyethylene(PE)

designs

Shield: •Tinned,barecopperoraluminumbraid •Flexfoil® shield

Jacket: •PremiumPVCcompoundor

PEcompound

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •CATV •MATV •HDTV •Digitalvideo •Directburial •SeeCoaxConnectorCrossReference,

pages 192-199

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

C5785RG 6/U TypeQuad-ShieldUL CL2, CATV, CMc(UL) CM

18 Ga.Solid

Copper-Clad Steel

28.9 Ω/Mft.

Foam PE (2) 100% Flexfoil®

1st Bonded(1) 60%(2) 40%

Aluminum Braids3.7 Ω/Mft.

Black PVC 16.20 53.15 83 75 11050

100200500

10001450180022003000

0.260.811.462.052.834.536.598.108.80

10.1011.79

0.180 4.57 0.292 7.42

C5889RG 6/U TypeRiserQuad-ShieldUL CL2R, CATVR, CMRc(UL) CM

18 Ga.Solid

Copper-Clad Steel

28.9 Ω/Mft.

Foam PE (2) 100% Flexfoil®

1st Bonded(1) 60%(2) 40%

Aluminum Braids3.7 Ω/Mft.

Black PVC 16.20 53.15 83 75 11050

100200500

10001450180022003000

0.260.811.462.052.834.536.598.108.80

10.1011.79

0.180 4.57 0.292 7.42

C5777RG 6/U TypeUL CL2, CATV, CMc(UL) CM

18 Ga.Solid

Copper-Clad Steel

28.9 Ω/Mft.

Foam PE 100% Flexfoil®

Bonded+61%

Tinned CopperBraid

6.5 Ω/Mft.

Black PVC 16.20 53.15 83 75 11050

100200500

10001450180022003000

0.260.811.462.052.834.536.598.108.80

10.1011.79

0.180 4.57 0.275 6.98

C5802RG 6/U TypeMessengered,Self-Supporting

18 Ga.Solid

Copper-Clad Steel

28.9 Ω/Mft.

Foam PE 100% Flexfoil®

Bonded+60%

Aluminum Braid9.0 Ω/Mft.

Black PVC 16.20 53.15 83 75 11050

100200500

1000

0.260.811.462.052.834.536.59

0.180 4.57 0.270x

0.428

6.86x

10.87

C5804RG 6/U TypeMoistureGuard™Direct Burial, Flooded

18 Ga.Solid

Copper-Clad Steel

28.9 Ω/Mft.

Foam PE 100% Flexfoil®

Bonded+60%

Aluminum Braidw/water block

9.0 Ω/Mft.

Black PE 16.20 53.15 83 75 11050

100200500

1000

0.260.811.462.052.834.536.59

0.180 4.57 0.275 6.98

FlexFill®

Page 101: Cross-Reference & Online Spec Sheets - Datasheet Archive

90

Electronics Coaxial Cable

RG 6/U Type

Product Construction: Conductors: •CopperperASTMB-3 •Copper-cladsteelperASTMB-869

Insulation/Core: •Foampolyethylene(PE)design

Shield: •Tinnedcopperoraluminumbraid •Flexfoil® shield

Jacket: •PremiumPVCcompound

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •LANcable •HDTV •CCTV† •Digitalvideo •Directbroadcastsatellite •SeeCoaxConnectorCrossReference,

pages 192-199

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

C5814†RG 6/U TypeDigital Video/HDTVUL CL2, CATV, CMc(UL) CM

18 Ga.Solid Bare

Copper6.5 Ω/Mft.

Foam PE 100% Flexfoil®

+95%Tinned Copper

Braid2.7 Ω/Mft.

Black PVC16.20 53.15 83 75 1

1050

100200500

10001450180022003000

0.200.721.482.012.794.466.537.868.769.69

11.31

0.180 4.57 0.275 6.98

C5822RG 6/U Dual-TypeDBSUL CL2, CATV, CMc(UL) CM

18 Ga.Solid

Copper-Clad Steel

28.9 Ω/Mft.

Foam PE 100% Flexfoil®

Bonded+60%

Aluminum Braid9.0 Ω/Mft.

Black PVC16.20 53.15 83 75 1

1050

100200500

10001450180022003000

0.260.811.462.052.834.536.598.108.80

10.1011.79

0.180 4.57 0.267x

0.595

6.86x

15.11

Page 102: Cross-Reference & Online Spec Sheets - Datasheet Archive

91

Coaxial Cable Electronics

RG 6/U TypeProduct Construction: Conductors: •CopperperASTMB-3

orcopper-cladsteelperASTMB-869 •Twistedpaircolorcode:blackandred

Insulation/Core: •Foampolyethylene(PE)design •Foamfluoropolymer(FEP)design

Shield: •Tinnedcopperoraluminumbraid •Flexfoil® shield

Jacket: •Premium-gradePVCcompound

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •SuitableforRFsignaltransmission •CATV •CCTV† •DBS •Dropcable •FMbroadcast •HDTV •Digitalvideo •SeeCoaxConnectorCrossReference,

pages 192-199

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

C5778RG 6/U TypeUL CL2, CATV, CMc(UL) CM

18 Ga.Solid Bare

Copper6.5 Ω/Mft.

Foam PE 100% Flexfoil®

Bonded+61%

Tinned CopperBraid

6.5 Ω/Mft.

Black PVC16.20 53.15 83 75 1

1050

100200500

10001450180022003000

0.260.811.462.052.834.536.598.108.80

10.1011.79

0.180 4.57 0.275 6.98

C3523RG 6/U TypePlenumUL CL2P, CMPc(UL) CMP

18 Ga.Solid Bare

Copper6.5 Ω/Mft.

Fluoropolymer 100% Flexfoil®

+80%Tinned Copper

Braid2.3 Ω/Mft.

Flexguard® PVC Natural

16.40 52.50 83 75 11050

100200500

1000

0.300.661.502.103.105.007.30

0.170 4.32 0.232 5.89

C3521RG 6/U TypePlenumUL CL2P, CMPc(UL) CMP

18 Ga.Solid Bare

Copper6.5 Ω/Mft.

Fluoropolymer Flexfoil® Bonded+95%

Tinned Copper Braid

2.3 Ω/Mft.

Flexguard® PVC Natural

16.00 52.50 83 75 11050

100200500

1000

0.300.661.502.103.105.007.30

0.170 4.32 0.232 5.89

C3524RG 6/U TypePlenumUL CL2P, CMPc(UL) CMP

18 Ga.Solid

Copper-Clad Steel

28.6 Ω/Mft.

FluoropolymerFlexfoil® Bonded

+80%Aluminum Braid

9.0 Ω/Mft.

Flexguard® PVC Natural

16.00 52.50 83 75 11050

100200500

100023003000

0.300.661.502.103.105.007.30

12.2014.28

0.170 4.32 0.232 5.89

C3525RG 6/U TypeQuad ShieldPlenumUL CL2P, CMPc(UL) CMP

18 Ga.Solid

Copper-Clad Steel

28.6 Ω/Mft.

Fluoropolymer (2) 100% Flexfoil®

(1) 60%(2) 40%

Aluminum Braids5.3 Ω/Mft.

Flexguard® PVC Natural

16.00 52.50 83 75 11050

100200500

100023003000

0.300.661.502.103.105.007.30

12.2014.28

0.170 4.32 0.306 7.77

C8029†RG 6/U Type+18 AWG Unshielded PairUL CL2, CATV, CMc(UL) CM

18 Ga.Solid Bare

Copper Coax

18 AWG (7/26)

Unshielded Pair

Foam PE 100% Flexfoil®

95% BareCopper Braid1.9 Ω/Mft.

Unshielded Pair

Black PVC 16.20 53.15 83 75 11050

100200500

1000

0.200.721.482.012.704.466.53

0.180 4.57 0.270x

0.493

6.86x

12.52Premium PVC

0.010 0.25

C8031†RG 6/U Type+18 AWG Unshielded PairUL CMPc(UL) CMP

18 AWG Solid Bare

Copper Coax

18 AWG (7/26)

Unshielded Pair

Fluoropolymer 95% Bare CopperBraid

3.5 Ω/Mft.

Unshielded Pair

Natural PVC 16.30 53.48 83 75 11050

100200500

1000

0.300.661.502.103.105.007.30

0.170 0.432 0.232x

0.416

5.89x

10.57Halar

0.006 0.15

Page 103: Cross-Reference & Online Spec Sheets - Datasheet Archive

92

Electronics Coaxial Cable

RG 6/U TypeProduct Construction: Conductors: •CopperperASTMB-3

Insulation/Core: •Foampolyethylene(PE)design

Shield: •Tinnedcopperbraid •Flexfoil® shield

Jacket: •Premium-gradePVCcompound

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •Broadlastgradeheadend •SerialDigitalInterface(SDI) •CATV •DBS •Dropcable •HDTV •CCTV† •Digitalvideo •SeeCoaxConnectorCrossReference,

pages 192-199

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

395011UL CMRc(UL) CMG

18 Ga.Solid Bare

Copper6.5 Ω/Mft.

Foam PEDual Foil

+ 95% TinnedCopper Braid

Shield2.8 Ω/Mft.

Flame-RetardantPVC

16.20 53.10 83 75 13.6135270540

150022503000

0.240.452.102.974.257.339.14

10.67

0.180 4.57 0.275 6.91

495035†UL CMPc(UL) CMP 75°C

18 Ga.Solid Bare

Copper6.7 Ω/Mft.

Fluoropolymer 95% BareCopper Braid2.0 Ω/Mft.

Plenum PVC 16.20 52.50 83 75 11050

100200540

1000 150022503000

0.210.651.462.042.985.187.058.64

10.5812.21

0.170 4.32 0.232 5.89

495036†UL CMPc(UL) CMP 105°C

18 Ga.Solid Bare

Copper6.7 Ω/Mft.

Fluoropolymer 95% BareCopper Braid2.0 Ω/Mft.

PVDF 16.10 53.00 83 75 11050

100200540

1000 150022503000

0.210.651.462.042.985.187.058.64

10.5812.21

0.170 4.32 0.232 5.89

495025UL CMPc(UL) CMP

18 Ga.Solid Bare

Copper6.5 Ω/Mft.

Fluoropolymer Dual Foil + 95% TinnedCopper Braid

Shield2.8 Ω/Mft.

Plenum PVC 16.10 53.00 83 75 13.6135270540

150022503000

0.240.452.402.754.006.36

11.6013.70

0.170 4.32 0.232 5.89

Page 104: Cross-Reference & Online Spec Sheets - Datasheet Archive

93

Coaxial Cable Electronics

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

395011-3UL CMRc(UL) CMG

18 Ga.3/Cond.

Solid BareCopper

6.5 Ω/Mft.

Foam PEBi-Metal Foil

+ 95% TinnedCopper Braid

Shield(2.8 Ohm)

Inner:Flame-Retardant

PVCOuter:

TPE matte

16.20 53.20 83 75 13.6

71.5270540

1500

0.240.451.602.974.257.33

0.180 4.57

0.685 17.40

395011-4UL CMRc(UL) CMG

18 Ga.4/Cond.

Solid BareCopper

6.5 Ω/Mft.

Foam PEBi-Metal Foil

+ 95% TinnedCopper Braid

Shield(2.8 Ohm)

Inner:Flame-Retardant

PVCOuter:

TPE matte

16.20 53.20 83 75 13.6

71.5270540

1500

0.240.451.602.974.257.33

0.180 4.57

0.755 19.18

395011-5UL CMRc(UL) CMG

18 Ga.5/Cond.

Solid BareCopper

6.5 Ω/Mft.

Foam PEBi-Metal Foil

+ 95% TinnedCopper Braid

Shield(2.8 Ohm)

Inner:Flame-Retardant

PVCOuter:

TPE matte

16.20 53.20 83 75 13.6

71.5270540

1500

0.240.451.602.974.257.33

0.180 4.57

0.860 21.85

Inner Jacket Color Code ChartOrdering

Suffix COLOR

1 Red

2 Green

3 Blue

4 White

5 YellowNote:395011-3willhavethefirstthreecolors, 395011-4willhavethefirstfourcolors and395011-5willhaveallfivecolors.

Product Construction: Conductors: •CopperperASTMB-3

Insulation/Core: •Foampolyethylene(PE)design

Shield: •DualFlexfoil® shield •Tinnedcopperbraid

Jacket: •Outerjacket:blackmattefinish

thermoplasticelastomer(TPE) •Innerjacket:flame-retardantPVC;

see color codes below

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •Analog/DigitalVideoBroadcast-Grade

Monitor •HDTV •SeeCoaxConnectorCrossReference,

pages 192-199

RG 6/U Multi-Channel Digital/Precision, Riser Rated 75OhmHigh-EndCoaxialCablesforExactingVideo,Analog,Digital&MonitorApplications

Page 105: Cross-Reference & Online Spec Sheets - Datasheet Archive

94

Electronics Coaxial Cable

RG 8/U Type

Product Construction: Conductors: •CopperperASTMB-3

Insulation/Core: •Solidandcellularpolyethylenedesigns

Shield: •Tinnedorbarecopperbraid •Flexfoil® shield

Jacket: •PremiumPVCcompound

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •SuitableforRFsignaltransmission •Broadcast •SeeCoaxConnectorCrossReference,

pages 192-199

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

C1108ARG 8/U Mini TypeUL CL2, CMCSA CMG 1354

16 Ga.(19/28)

BareCopper

4.2 Ω/Mft.

Foam PE95% Bare

Copper Braid3.3 Ω/Mft.

Black PVC25.30 83.01 80 50 1

1050

100200500

1000

0.260.982.303.304.908.50

14.30

0.155 3.94 0.242 6.15

C1154RG 8/U TypeJAN-C-17A TYPE 1354

13 Ga.(7/21)Bare

Copper1.9 Ω/Mft.

Solid PE95% Bare

Copper Braid1.2 Ω/Mft.

Black PVC29.50 96.79 66 52 1

1050

100200500

1000

0.160.561.301.902.804.707.40

0.285 7.24 0.405 10.29

C1198RG 8/U Type 1354

11 Ga.(19/24)

BareCopper

1.9 Ω/Mft.

Foam PE95% Bare

Copper Braid1.1 Ω/Mft.

Black PVC26.00 85.31 78 50 1

1050

100200500

1000

0.170.571.201.802.704.707.10

0.285 7.24 0.405 10.29

C1180RG 8/U Type

9½ Ga.Solid Bare

Copper0.90 Ω/Mft.

Semi-Solid PE100% Flexfoil®

Bonded+88%

Tinned Copper Braid

1.8 Ω/Mft.

Black PVC24.60 80.71 84 50 1

1050

100200500

1000

0.130.400.901.301.803.004.50

0.285 7.24 0.405 10.29

Page 106: Cross-Reference & Online Spec Sheets - Datasheet Archive

95

Coaxial Cable Electronics

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

397001RG 8/U TypeTHICKNETDEC 17-000451-00UL CM c(UL)

12 Ga.Solid Bare

Copper1.42 Ω/Mft.

Foam PEQuad Shield

Dual Flexfoil®

94% Tinned Copper Braid

+ Dual Flexfoil®

94% Tinned Copper Braid1.52 Ω/Mft.

Yellow Flame-Retardant

PVC

26.00 85.30 78 50 15

1050

100200400700900

1000

0.170.370.531.201.732.503.644.975.746.10

0.245 6.22 0.405 10.29

497001RG 8/U TypeTHICKNETDEC 17-000324-00UL CMP c(UL)

12 Ga.Solid Bare

Copper1.42 Ω/Mft.

Fluoropolymer Quad ShieldDual Flexfoil®

94% Tinned Copper Braid

+ Dual Flexfoil®

94% Tinned Copper Braid1.52 Ω/Mft.

Orange PVDF

25.00 82.00 84 50 15

1050

100200400700900

1000

0.160.350.511.191.752.613.975.656.677.14

0.245 6.22 0.375 9.53

RG 8/U Type Thicknet/Trunk Cable 50OhmIEEE802.3andISO/IEC8802.310Base5LANandComputerCables

Product Construction: Conductors: •CopperperASTMB-3

Insulation/Core: •Foampolyethylene(PE)design •Foamfluoropolymer(FEP)design

Shield: •Tinnedcopperbraid •Flexfoil® shield

Jacket: •PremiumPVCcompound •Premiumfluoropolymercompound

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •LAN&datatransmissioncomputercables •Thicknet/trunkcable–IEEE802.3

andISO/IEC8802.310base5LANcomputer cables

•SeeCoaxConnectorCrossReference, pages 192-199

Page 107: Cross-Reference & Online Spec Sheets - Datasheet Archive

96

Electronics Coaxial Cable

RG 11/U Type

Product Construction: Conductors: •CopperperASTMB-3 •Copper-cladsteelperASTMB-869

Insulation/Core: •Solidandfoampolyethylene(PE)

designs

Shield: •Tinned,barecopperoraluminumbraid •Flexfoil® shield

Jacket: •PremiumPVCcompoundor

PEcompound

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •SuitableforRFsignaltransmission •Broadcastdigitalvideo •MATV •CATV† •Dropcable •HDTV •CCTV •SeeCoaxConnectorCrossReference,

pages 192-199

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

C1160RG 11/U TypeJAN-C-17A Type

18 Ga.(7/26)TinnedCopper

6.1 Ω/Mft.

Solid PE95% Bare

Copper Braid1.2 Ω/Mft.

Black PVC 20.50 67.26 66 75 11050

100200500

1000

0.200.701.302.002.904.707.10

0.285 6.55 0.400 10.16

C5011†RG 11/U TypeUL CL2, CATV, CMc(UL) CM

14 Ga.SolidBare

Copper2.5 Ω/Mft.

Foam PE 100% Flexfoil®

+95%Bare Copper

Braid1.2 Ω/Mft.

Black PVC 16.20 53.15 85 75 11050

100200500

10001450180022003000

0.130.400.901.301.903.004.405.305.906.537.62

0.280 7.11 0.395 10.03

C5025RG 11/U Type

14 Ga.Solid

Copper-Clad Steel

11.4 Ω/Mft.

Foam PE 97% BareCopper Braid1.2 Ω/Mft.

Black PE 16.20 53.15 83 75 11050

100200500

10001450180022003000

0.300.701.001.502.203.705.306.387.117.869.18

0.285 7.24 0.405 10.29

C5029RG 11/U TypeUL CL2, CMc(UL) CM

14 Ga.Solid

Copper-Clad Steel

11.4 Ω/Mft.

Foam PE100% Flexfoil®

Bonded+61%

Tinned CopperBraid

3.0 Ω/Mft.

Black PVC16.20 53.15 85 75 1

1050

100200500

10001450180022003000

0.300.700.901.301.903.004.405.305.906.537.62

0.280 7.11 0.395 10.03

C5034RG 11/U Type 1354

14 Ga.Solid

Copper-Clad Steel

11.4 Ω/Mft.

Foam PE100% Flexfoil®

Bonded+40%

Aluminum Braid5.3 Ω/Mft.

Black PVC 16.20 53.15 85 75 11050

100200500

1000

0.300.700.901.301.903.004.40

0.280 7.11 0.395 10.03

Page 108: Cross-Reference & Online Spec Sheets - Datasheet Archive

97

Coaxial Cable Electronics

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

C5039RG 11/U TypeUL CL2, CATV, CMCSA CMG 1354

14 Ga.Solid

Copper-Clad Steel

11.4 Ω/Mft.

Foam PE 100% Flexfoil®

Bonded+60%

Aluminum Braid4.6 Ω/Mft.

Black PVC 16.20 53.15 85 75 11050

100200500

10001450180022003000

0.300.700.901.301.903.004.405.305.906.537.62

0.280 7.11 0.395 10.03

C5044RG 11/U TypeQuad-ShieldUL CL2, CATV, CMCSA CMG 1354

14 Ga.Solid

Copper-Clad Steel

11.4 Ω/Mft.

Foam PE (2) 100% Flexfoil®

1st Bonded(1) 61%(2) 40%

Aluminum Braids3.4 Ω/Mft.

Black PVC 16.20 53.15 85 75 11050

100200500

10001450180022003000

0.300.700.901.301.903.004.405.305.906.537.62

0.280 7.11 0.405 10.29

C3528RG 11/U TypePlenumUL CL2P, CMPc(UL) CMP CATVP

14 Ga.Solid

Copper-Clad Steel

11.4 Ω/Mft.

Fluoropolymer100% Flexfoil®

+60%Aluminum Braids

4.6 Ω/Mft.

PVDF Jacket16.00 52.50 82 75 1

1050

100200500

1000145018002200

0.150.471.091.492.353.946.19 7.458.309.18

0.280 7.11 0.351 8.92

RG 11/U Type

Product Construction: Conductor: •CopperperASTMB-3 •Copper-cladsteelperASTMB-3

Insulation/Core: •Foampolyethylene(PE)design •Foamfluoropolymer(FEP)design

Shield: •Tinned,barecopperoraluminumbraid •Flexfoil® shield

Jacket: •PremiumPVCcompound,Flexguard® or

PEcompound

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •SuitableforRFsignaltransmission •Broadcastdigitalvideo •MATV •CATV •Dropcable •HDTV •Directburial •SeeCoaxConnectorCrossReference,

pages 192-199

Page 109: Cross-Reference & Online Spec Sheets - Datasheet Archive

98

Electronics Coaxial Cable

RG 11/U Type

Product Construction: Conductor: •StrandedorsolidcopperperASTMB-3 •Copper-cladsteelperASTMB-869

Insulation/Core: •Foampolyethylene(PE)design •Foamfluoropolymer(FEP)design

Shield: •Barecopperoraluminumbraid •Flexfoil® shield

Jacket: •Premiumfluoropolymercompoundor

premiumpolythylene(PE)compound

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •SuitableforRFsignaltransmission •Broadcast/digitalvideo •MATV •CATV •Dropcable •HDTV •Directburial •SeeCoaxConnectorCrossReference,

pages 192-199

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

C3529RG 11/U TypeQuad-ShieldPlenumUL CL2P, CMPc(UL) CMP CATVP

14 Ga.Solid

Copper-Clad Steel

11.4 Ω/Mft.

Fluoropolymer(2) 100% Flexfoil®

(1) 60%(2) 40%

Aluminum Braids3.4 Ω/Mft.

PVDF Jacket16.00 52.50 82 75 1

1050

100200500

1000145018002200

0.150.471.091.492.353.946.197.458.309.18

0.280 7.11 0.372 9.45

C5043RG 11/U TypeMoistureGuard™Direct Burial, Flooded

14 Ga.Solid

Copper-Clad Steel

11.4 Ω/Mft.

Foam PE100% Flexfoil®

Bonded+60%

Aluminum Braidw/water block

5.3 Ω/Mft.

Black PE16.20 53.15 85 75 1

1050

100200500

1000

0.300.700.901.301.903.004.40

0.280 7.11 0.395 10.03

FlexFill®

Page 110: Cross-Reference & Online Spec Sheets - Datasheet Archive

99

Coaxial Cable Electronics

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

395058†RG 11/U Type UL CMc(UL) CMG

14 Ga.Solid Bare

Copper2.6 Ω/Mft.

Foam PE95% Bare

Copper Braid1.2 Ω/Mft.

Flame-Retardant PVC

16.20 52.50 84 75 11050

100200400540

100022503000

0.170.350.901.301.902.903.374.596.887.94

0.285 7.24 0.405 10.29

395029RG 11/U Type UL CMRc(UL) CMG

14 Ga.Solid Bare

Copper2.6 Ω/Mft.

Foam PEDual Flexfoil® + 95% TinnedCopper Braid1.5 Ω/Mft.

Flame-Retardant PVC

16.20 53.10 83 75 13.6

135270540

150022503000

0.150.281.622.313.295.606.948.10

0.280 7.11 0.405 10.29

495015†RG 11/U Type UL CMPc(UL) CMP

14 Ga.Solid Bare

Copper2.6 Ω/Mft.

Fluoropolymer 95% BareCopper Braid1.2 Ω/Mft.

PVDF 16.20 52.50 84 75 11050

100200400540

100022503000

0.170.350.901.301.902.903.374.596.887.94

0.280 7.11 0.351 8.92

495016†RG 11/U Type UL CMPc(UL) CMP

14 Ga.Solid Bare

Copper2.6 Ω/Mft.

FluoropolymerDual Flexfoil®

+ 60% AL Braid3.0 Ω/Mft.

PVDF 16.20 53.10 84 75 11050

100200400540

100022503000

0.150.401.001.502.203.303.835.227.839.04

0.280 7.11 0.351 8.92

495027RG 11/U Type UL CMPc(UL) CMP

14 Ga.Solid Bare

Copper2.6 Ω/Mft.

FluoropolymerDual Flexfoil® + 95% TinnedCopper Braid

Shield1.5 Ω/Mft.

PVDF16.20 53.10 84 75 1

3.6135270540

150022503000

0.120.241.632.493.897.88

10.6112.35

0.280 7.11 0.348 8.84

RG 11/U Type Serial Digital Interface (SDI) Precision Cable Extended-Distance,75OhmHigh-EndCoaxialCablesforExactingVideo,Analog&DigitalApplications

Product Construction: Conductor: •CopperperASTMB-3

Insulation/Core: •Foampolyethylene(PE)design •Foamfluoropolymer(FEP)design

Shield: •Barecopperortinnedcopper •Flexfoil® shield

Jacket: •PremiumPVCcompoundor

fluoropolymer

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •SuitableforRFsignaltransmission •Broadcast-gradeSerialDigital

Interface(SDI) •Analog/digitalvideo •MATV •CATV •CCTV† •Dropcable •HDTV •SeeCoaxConnectorCrossReference,

pages 192-199

Page 111: Cross-Reference & Online Spec Sheets - Datasheet Archive

100

Electronics Coaxial Cable

RG 58/U Type

Product Construction: Conductors: •CopperperASTMB-3 •TinnedcopperperASTMB-33

Insulation/Core: •Solidandfoampolyethylene(PE)

designs •Solidandfoamfluoropolymer(FEP)

design

Shield: •Tinnedcopperbraid

Jacket: •PremiumPVCcompound

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •SuitableforRFsignaltransmission •Broadcast •LAN&datatransmission •SeeCoaxConnectorCrossReference,

pages 192-199

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

C1117RG 58/U Type

20 Ga.Solid Bare

Copper10.1 Ω/Mft.

Solid PE 70% Tinned Copper Braid6.0 Ω/Mft.

Black PVC 28.50 93.51 66 53 11050

100200500

1000

0.401.202.904.206.00

10.1716.50

0.116 2.95 0.195 4.95

C1155RG 58 C/U TypeMIL-C-17G Type

20 Ga.(19/.0071)

TinnedCopper

10.8 Ω/Mft.

Solid PE95% Tinned Copper Braid4.3 Ω/Mft.

Non-Contaminating Black PVC

30.80 101.05 66 50 11050

100200500

1000

0.421.503.705.408.10

13.8622.80

0.116 2.95 0.195 4.95

C1166RG 58/U TypeJAN-C-17A Type 1354

20 Ga.Solid Bare

Copper10.1 Ω/Mft.

Solid PE 95% Tinned Copper Braid4.3 Ω/Mft.

Black PVC 30.00 98.43 66 50 11050

100200500

1000

0.401.202.904.206.00

10.1716.50

0.116 2.95 0.195 4.95

C1178RG 58A/U TypeJAN-C-17A Type 1354

20 Ga.(19/.0071)

TinnedCopper

10.8 Ω/Mft.

Solid PE 95% Tinned Copper Braid4.3 Ω/Mft.

Black PVC 31.80 104.34 66 50 11050

100200500

1000

0.421.503.705.408.10

13.9622.80

0.116 2.95 0.195 4.95

C1188RG 58 A/U TypeUL CL2, CMCSA CMG 1354

20 Ga.(19/32)TinnedCopper

9.5 Ω/Mft.

Foam PE95% Tinned Copper Braid4.3 Ω/Mft.

Black PVC26.00 85.31 78 50 1

1050

100200500

1000

0.451.423.204.506.40

10.0614.50

0.114 2.90 0.195 4.95

C3519RG 58/U TypePlenumUL CL2P, CMPc(UL) CMP

19 Ga.Solid Bare

Copper8.1 Ω/Mft.

Fluoropolymer95% Tinned Copper Braid2.9 Ω/Mft.

Flexguard® PVCNatural

25.00 82.00 82 50 11050

100200500

1000

0.401.302.803.906.009.50

13.50

0.102 2.59 0.161 4.09

Page 112: Cross-Reference & Online Spec Sheets - Datasheet Archive

101

Coaxial Cable Electronics

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

C1102RG 59/U Type

20 Ga. SolidCopper-Clad

Steel45.9 Ω/Mft.

Foam PE95% Bare

Copper Braid 3.5 Ω/Mft.

Black PE17.30 56.76 82 75 1

1050

100200500

10001450180022003000

0.260.821.802.603.706.008.8010.6011.8113.0515.24

0.146 3.71 0.242 6.15

C1104RG 59/U Type 1354

22 Ga. SolidCopper-Clad

Steel73.4 Ω/Mft.

Solid PE95% Bare

Copper Braid 2.6 Ω/Mft.

Black PVC20.50 67.26 66 73 1

1050

100200500

10001450180022003000

0.410.992.383.495.098.4313.0315.6917.4819.3322.57

0.146 3.71 0.242 6.15

C1135RG 59/U TypeUL CL2, CATV, CMCSA CMG 1354

22 Ga. SolidCopper-Clad

Steel73.4 Ω/Mft.

Foam PE95% Bare

Copper Braid 2.6 Ω/Mft.

Black PVC16.30 53.48 78 80 1

1050

100200500

10001450180022003000

0.420.922.102.904.106.609.3011.2012.4813.7916.11

0.146 3.71 0.242 6.15

C1103†RG 59/U TypeUL CL2, CATV, CMCSA CMG 1354

22 Ga.(7/30)

Bare Copper14.8 Ω/Mft.

Foam PE95% Bare

Copper Braid2.6 Ω/Mft.

Black PVC17.00 55.78 78 76 1

1050

100200500

10001450180022003000

0.260.912.093.004.337.0310.6412.8114.2815.7818.43

0.146 3.71 0.242 6.15

C1142†RG 59/U TypeUL CL2, CATV, CM CSA CMG 1354

20 Ga. Solid Bare Copper10.1 Ω/Mft.

Foam PE95% Bare

Copper Braid 2.6 Ω/Mft.

Black PVC16.20 53.15 78 71 1

1050

100200500

10001450180022003000

0.250.781.972.793.976.359.1511.0212.2813.5715.85

0.146 3.71 0.234 5.94

C1106RG 59B/U TypeMIL-C-17D Type 1354

23 Ga. Solid Copper-Clad

Steel68.5 Ω/Mft.

Solid PE95% Bare

Copper Braid 2.6 Ω/Mft.

Non-ContaminatingBlack PVC

21.00 68.90 66 73 11050

100200500

10001450180022003000

0.441.022.443.555.188.5913.5616.3318.1920.1123.49

0.146 3.71 0.242 6.15

C8030†RG 59/U Type+18 AWG Unshielded PairUL CMP c(UL) CMP

20 AWG Solid BC Coax

18 AWG (7/26)Unshielded

Pair

Fluoropolymer 95% BareCopper Braid

Unshielded Pair

Natural PVC 16.30 53.48 83 75 11050

100200500

1000

0.781.901.982.804.106.829.64

0.135 3.43 0.200 X

0.383

5.08 X

9.73PVC

0.006 0.15

RG 59/U TypeProduct Construction: Conductors: •CopperperASTMB-3 •Copper-cladsteelperASTMB-869 •Twistedpaircolorcode:blackandred

Insulation/Core: •Solidandcellularpolyethylene(PE)

designsorfoamfluoropolymer(FEP)design

Shield: •Barecopperbraid

Jacket: •PremiumPVCcompoundor

PEcompound

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •SuitableforRFsignaltransmission •CATV •MATV •CCTV† •LocalAreaNetwork •Digitalvideo •Monitor/VDTdisplay •SeeCoaxConnectorCrossReference,

pages 192-199

Page 113: Cross-Reference & Online Spec Sheets - Datasheet Archive

102

Electronics Coaxial Cable

RG 59/U TypeProduct Construction: Conductors: •CopperperASTMB-3 •Copper-cladsteelperASTMB-869 •Twistedpaircolorcode:blackandred

Insulation/Core: •Solidandfoampolyethylene(PE)

designs

Shield: •Tinned,barecopperoraluminumbraid •Flexfoil® shield

Jacket: •PremiumPVCcompound

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •SuitableforRFsignaltransmission •MATV •CATV •CCTV† •LocalAreaNetwork •Monitor/VDTdisplay •Analogvideo •Digitalvideo •SeeCoaxConnectorCrossReference,

pages 192-199

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

C1110RG 59/U Type 1354

22 Ga. SolidCopper-Clad

Steel73.4 Ω/Mft.

Solid PE70% Bare

Copper Braid 4.5 Ω/Mft.

Black PVC22.00 72.18 66 73 1

1050

100200500

10001450180022003000

0.410.992.383.495.098.43

13.0315.6917.4819.3322.57

0.146 3.71 0.242 6.15

C1112RG 59/U Type

22 Ga. SolidCopper-Clad

Steel73.4 Ω/Mft.

Foam PE70% Bare

Copper Braid 4.5 Ω/Mft.

Black PVC16.30 53.48 78 80 1

1050

100200500

10001450180022003000

0.420.922.102.904.106.609.30

11.2012.4813.7916.11

0.146 3.71 0.242 6.15

C8025†RG 59/U Type+22 AWG Shielded PairUL CL2, CATV, CMc(UL) CM

22 AWG (7/30) Bare

Copper Coax

22 AWG (7/30)Shielded Pair

Foam PE95% Bare

Copper Braid

100% Flexfoil®

AI/PP Shielded

Black PVC17.00 57.78 78 76 1

1050

100200500

1000

0.260.912.903.004.337.03

10.64

0.144 3.66 0.242 X

0.445

6.147 X

11.30Premium PVC

0.013 0.33

Page 114: Cross-Reference & Online Spec Sheets - Datasheet Archive

103

Coaxial Cable Electronics

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

C5770RG 59/U TypeUL CL2, CATV, CMCSA CMG 1354

22 Ga. SolidCopper-Clad

Steel73.4 Ω/Mft.

Foam PE100% Flexfoil® Bonded + 40%

Aluminum Braid

11.0 Ω/Mft.

Black PVC16.00 52.50 78 80 1

1050

100200500

10001450180022003000

0.501.002.303.304.106.509.40

11.3212.6113.9416.28

0.144 3.66 0.231 5.87

C5780RG 59/U TypeMATVUL CL2, CATV, CMCSA CMG 1354

20 Ga.Solid

Copper-Clad Steel

45.9 Ω/Mft.

Foam PE100% Flexfoil® Bonded + 40%

Aluminum Braid

11.0 Ω/Mft.

Black PVC16.20 53.15 85 75 1

1050

100200500

10001450180022003000

0.601.201.952.703.705.708.129.78

10.8912.0414.06

0.144 3.66 0.234 5.94

C5830RG 59/U TypeTri-ShieldUL CL2, CATV, CMc(UL) CM

20 Ga.Solid

Copper-Clad Steel

45.9 Ω/Mft.

Foam PE100% Flexfoil® Bonded + 95%

Aluminum Braid +

100% Flexfoil®

3.0 Ω/Mft.

Black PVC16.20 53.15 85 75 1

1050

100200500

10001450180022003000

0.601.201.952.703.705.708.129.78

10.8912.0414.06

0.144 3.66 0.242 6.15

C5784RG 59/U TypeQuad-ShieldUL CL2, CATV, CMCSA CMG 1354

20 Ga.Solid

Copper-Clad Steel

45.9 Ω/Mft.

Foam PE100% Flexfoil®

1st Bonded (1) 67% (2) 46%

Aluminum Braids

4.1 Ω/Mft.

Black PVC16.20 53.15 85 75 1

1050

100200500

10001450180022003000

0.601.201.952.703.705.708.129.78

10.8912.0414.06

0.144 3.66 0.270 6.86

RG 59/U Type

Product Construction: Conductors: •Copper-cladsteelperASTMB-869

Insulation/Core: •Foampolyethylene(PE)design

Shield: •Aluminumbraid •Flexfoil® shield

Jacket: •PremiumPVCcompound

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •SuitableforRFsignaltransmission •CATV •MATV •Dropcable •LocalAreaNetwork •Monitor/VDTdisplay •SeeCoaxConnectorCrossReference,

pages 192-199

Page 115: Cross-Reference & Online Spec Sheets - Datasheet Archive

104

Electronics Coaxial Cable

RG 59/U Type

Product Construction: Conductors: •Copper-cladsteelperASTMB-869 •CopperperASTMB-3 •Twistedpaircolorcode:blackandred

Insulation/Core: •Foampolyethylene(PE)design

Shield: •Barecopperoraluminumbraid •Flexfoil® shield

Jacket: •PremiumPVCcompound

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •SuitableforRFsignaltransmission •MATV •CATV •CCTV† •LocalAreaNetwork •Monitor/VDTdisplay •Directburial •SeeCoaxConnectorCrossReference,

pages 192-199

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

C3526RG 59/U TypePlenumUL CL2P, CMPc(UL) CMP

20 Ga.Solid

Copper-Clad Steel

45.9 Ω/Mft.

Fluoropolymer100% Flexfoil®

+65%Aluminum Braid

10.7 Ω/Mft.

Flexguard® Natural

16.00 52.50 84 75 11050

100200500

10002300

0.341.071.772.503.535.988.45

14.10

0.135 3.429 0.202 5.13

C3527RG 59/U TypeQuad-Shield PlenumUL CL2P, CMPc(UL) CMP

20 Ga.Solid

Copper-Clad Steel

45.9 Ω/Mft.

Fluoropolymer(2) 100% Flexfoil®

(1) 60%(2) 40%

Aluminum Braid6.3 Ω/Mft.

Flexguard® Natural

16.00 52.50 84 75 11050

100200500

10002300

0.341.071.772.503.535.988.45

14.10

0.135 3.429 0.235 5.97

C3500RG 59/U TypePlenumUL CL2P, CMPc(UL) CMP

20 Ga.Solid

Copper-Clad Steel

45.9 Ω/Mft.

Fluoropolymer95% Bare

Copper Braid1.9 Ω/Mft.

Flexguard® PVC Natural

16.50 54.14 83 75 11050

100200500

1000

0.781.901.982.804.106.829.64

0.145 3.68 0.201 5.11

C8027†RG 59/U Type+18 AWG Shielded PairUL CL2, CATV, CMc(UL) CM

22 AWG(7/30) Bare

Copper Coax18 AWG (16/30)

Shielded Pair

Foam PE95% Bare

Copper Braid

125% Flexfoil®

AI/PP Shielded

Black PVC17.00 55.78 78 76 1

1050

100200500

1000

0.260.912.093.004.337.03

10.64

0.144 3.66 0.242 X

0.480

6.15 X

12.19Premium PVC

0.016 0.41

C8028†RG 59/U Type+18 AWG Unshielded PairUL CL2, CATV, CMc(UL) CM

20 AWGSolid Bare

Copper Coax18 AWG (7/26)

Unshielded Pair

Foam PE95% Bare

Copper Braid

Unshielded Pair

Black PVC16.20 53.15 78 71 1

1050

100200500

1000

0.250.781.972.703.976.359.15

0.144 3.66 0.238 X

0.440

6.05 X

11.18Premium PVC

0.010 0.25

Page 116: Cross-Reference & Online Spec Sheets - Datasheet Archive

105

Coaxial Cable Electronics

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

C1158RG 59/U TypeMiniature Type 1354

27 Ga.(7/35)

StrandedCopper-Clad

Steel120.0 Ω/Mft.

Solid PE93% Tinned Copper Braid6.5 Ω/Mft.

Black PVC20.50 67.26 66 75 1

1050

100200500

1000

1.202.404.205.708.30

13.5320.00

0.100 2.54 0.150 3.81

495028†RG 59/U TypeUL CMPc(UL) CMP

20 Ga.Solid Bare

Copper10.5 Ω/Mft.

Fluoropolymer95% Bare

Copper Braid Shield

2.7 Ω/Mft.

Plenum PVC16.00 52.50 84 75 1

1050

100200400

0.241.411.832.643.845.64

0.139 3.43 0.197 5.00

RG 59/U Precision & Miniature Cable 75OhmHigh-EndCoaxialCablesforVideo,AnalogandDigitalApplications

Product Construction: Conductors: •Copper-cladsteelperASTMB-869 •CopperperASTMB-3

Insulation/Core: •Solidpolyethylene(PE)designs •Foamfluoropolymer(FEP)design

Shield: •Bareortinnedcopper,aluminumbraid •Flexfoil® shield

Jacket: •PremiumPVCcompound

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •SuitableforRFsignaltransmission •Broadcast-grade •MATV •CATV •CCTV† •Precisionvideo–analog/digital •SeeCoaxConnectorCrossReference,

pages 192-199

Page 117: Cross-Reference & Online Spec Sheets - Datasheet Archive

106

Electronics Coaxial Cable

RG 59 Serial Digital Interface Cable 75OhmHigh-EndCoaxialCablesforVideo,Analog&DigitalApplications

Product Construction: Conductors: •CopperperASTMB-3

Insulation/Core: •Foampolyethylene(PE)designs •Foamfluoropolymer(FEP)design

Shield: •Tinnedcopperbraid •Flexfoil® shield

Jacket: •PremiumPVCcompound

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •SuitableforRFsignaltransmission •Broadcast-grade •MATV •CATV •Precisionvideo–analog/digital •Serialdigitalinterfacecable(SDI) •SeeCoaxConnectorCrossReference,

pages 192-199

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

395025RG 59/U TypeUL CMRc(UL) CMG

20 Ga.Solid Bare

Copper10.5 Ω/Mft.

Foam PEBi-Metal Foil +95% Tinned Copper Braid

Shield3.5 Ω/Mft.

Flame-Retardant PVC

16.30 53.40 83 75 1135270540

150022503000

0.292.703.805.479.30

11.5113.31

0.146 3.71 0.242 6.15

495023RG 59/U TypeUL CMPc(UL) CMP

20 Ga.Solid Bare

Copper10.5 Ω/Mft.

FluoropolymerBi-Metal Foil +95% TinnedCopper Braid

Shield3.2 Ω/Mft.

Plenum PVC16.10 53.00 84 75 1

1050

100200400540

100022503000

0.291.031.882.503.855.536.408.56

17.5021.90

0.135 3.43 0.199 5.05

Page 118: Cross-Reference & Online Spec Sheets - Datasheet Archive

107

Coaxial Cable Electronics

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

RG 59/U SERIAL DIGITAL INTERFACE (SDI), PRECISION COAX, RISER RATED

395025-3RG 59/U TypeUL CMRc(UL) CMG

20 Ga.3/Cond.

Solid Bare Copper

10.5 Ω/Mft.

Foam PEBi-Metal Foil +95% TinnedCopper Braid

Shield3.5 Ω/Mft.

Inner: Flame-Retardant

PVCOuter:

TPE Matte

16.30 52.40 83 75 171.5135270540

150022503000

0.292.102.703.805.479.30

11.5113.31

0.146 3.71

0.610 15.49

395025-4RG 59/U TypeUL CMRc(UL) CMG

20 Ga.4/Cond.

Solid Bare Copper

10.5 Ω/Mft.

Foam PEBi-Metal Foil +95% TinnedCopper Braid

Shield3.5 Ω/Mft.

Inner: Flame-Retardant

PVCOuter:

TPE Matte

16.30 52.40 83 75 171.5135270540

150022503000

0.292.102.703.805.479.30

11.5113.31

0.146 3.71

0.670 17.04

395025-5RG 59/U TypeUL CMRc(UL) CMG

20 Ga.5/Cond.

Solid Bare Copper

10.5 Ω/Mft.

Foam PEBi-Metal Foil +95% TinnedCopper Braid

Shield3.5 Ω/Mft.

Inner: Flame-Retardant

PVCOuter:

TPE Matte

16.30 52.40 83 75 171.5135270540

150022503000

0.292.102.703.805.479.30

11.5113.31

0.146 3.71

0.745 18.87

395025-10RG 59/U TypeUL CMRc(UL) CMG

20 Ga.10/Cond.Solid Bare

Copper10.5 Ω/Mft.

Foam PEBi-Metal Foil +95% TinnedCopper Braid

Shield3.5 Ω/Mft.

Inner: Flame-Retardant

PVCOuter:

TPE Matte

16.30 52.40 83 75 171.5135270540

150022503000

0.292.102.703.805.479.30

11.5113.31

0.146 3.71

1.110 28.19

RG 59/U MINI SERIAL DIGITAL INTERFACE (SDI), PRECISION COAX, RISER RATED

395031-3RG 59/U TypeUL CMRc(UL) CMG

23 Ga.3/Cond.

Solid Bare Copper

20.1 Ω/Mft.

Foam PEBi-Metal Foil +95% TinnedCopper Braid

Shield7.6 Ω/Mft.

Inner: Flame-Retardant

PVCOuter:

TPE Matte

16.50 54.10 83 75 171.5135270540

150022503000

0.393.063.815.407.70

13.0016.0018.50

0.102 2.59

0.415 10.58

395031-5RG 59/U TypeUL CMRc(UL) CMG

23 Ga.5/Cond.

Solid Bare Copper

20.1 Ω/Mft.

Foam PEBi-Metal Foil +95% TinnedCopper Braid

Shield7.6 Ω/Mft.

Inner: Flame-Retardant

PVCOuter:

TPE Matte

16.50 54.10 83 75 171.5135270540

150022503000

0.393.063.815.407.70

13.0016.0018.50

0.102 2.59

0.510 12.95

RG 59/U (RGB) Multi-Channel Digital/Precision Cable 75OhmHigh-EndCoaxialCablesforVideo,Analog&MonitorApplications

Product Construction: Conductors: •SolidbarecopperperASTMB-3

Insulation/Core: •Foampolyethylene(PE)design

Shield: •Tinnedcopperbraid •Flexfoil® shield

Jacket: •Outerjacket:mattefinishthermoplastic

elastomer(TPE) •Innerjacket:flame-retardantPVC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •SuitableforRFsignaltransmission •Broadcast •HDTV •Video–analog/digital •Monitorapplications •SeeCoaxConnectorCrossReference,

pages 192-199

Page 119: Cross-Reference & Online Spec Sheets - Datasheet Archive

108

Electronics Coaxial Cable

RG 59/U (RGB) Miniature Multi-Channel Precision Cable 75OhmHigh-EndCoaxialCablesforVideo,Analog&MonitorApplications

Product Construction: Conductors: •SolidbarecopperperASTMB-3

Insulation/Core: •Foampolyethylene(PE)design

Shield: •Tinnedcopperbraid •Flexfoil® shield

Jacket: •Outerjacket:mattefinishthermoplastic

elastomer(TPE) •Innerjacket:flame-retardantPVC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •SuitableforRFsignaltransmission •Broadcast •HDTV •Video–analog/digital •Monitorapplications •SeeCoaxConnectorCrossReference,

pages 192-199

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

RG 59/U (RGB) RISER RATED

395035-3RG 59/U TypeUL CMRc(UL) CMG

26 Ga.3/Cond.Stranded

(7/34)Bare Copper39.7 Ω/Mft.

Foam PEBi-Metal Foil +95% TinnedCopper Braid

Shield8.6 Ω/Mft.

Inner: Flame-Retardant

PVCOuter:

TPE Matte

17.30 56.74 78 75 11050

100200400540

100022503000

0.561.483.205.186.959.36

10.8815.7923.6927.35

0.089 2.26

0.435 11.05

395035-4RG 59/U TypeUL CMRc(UL) CMG

26 Ga.4/Cond.Stranded

(7/34)Bare Copper39.7 Ω/Mft.

Foam PEBi-Metal Foil +95% TinnedCopper Braid

Shield8.6 Ω/Mft.

Inner: Flame-Retardant

PVCOuter:

TPE Matte

17.30 56.74 78 75 11050

100200400540

100022503000

0.561.483.205.186.959.36

10.8815.7923.6927.35

0.089 2.26

0.460 11.70

395035-5RG 59/U TypeUL CMRc(UL) CMG

26 Ga.5/Cond.Stranded

(7/34)Bare Copper39.7 Ω/Mft.

Foam PEBi-Metal Foil +95% TinnedCopper Braid

Shield8.6 Ω/Mft.

Inner: Flame-Retardant

PVCOuter:

TPE Matte

17.30 56.74 78 75 11050

100200400540

100022503000

0.561.483.205.186.959.36

10.8815.7923.6927.35

0.089 2.26

0.480 12.19

Page 120: Cross-Reference & Online Spec Sheets - Datasheet Archive

109

Coaxial Cable Electronics

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

C1162RG 62A/U TypeMIL-C-17G Type 1354

22 Ga.Solid

Copper-Clad Steel

73.4 Ω/Mft.

Semi-Solid PE 95% BareCopper Braid2.6 Ω/Mft.

Non-ContaminatingBlack PVC

13.60 44.62 84 93 11050

100200500

1000

0.380.851.902.703.805.908.70

0.146 3.71 0.242 6.15

C1164RG 62/U TypeComputer CableJAN-C-17A TypeUL CL2, CMCSA CMG 1354

22 Ga.Solid

Copper-Clad Steel

73.4 Ω/Mft.

Semi-Solid PE95% Bare

Copper Braid2.6 Ω/Mft.

Black PVC13.60 44.62 84 93 1

1050

100200500

1000

0.380.851.902.703.805.908.70

0.146 3.66 0.242 6.15

C3520RG 62/U TypePlenumUL CL2P, CMPc(UL) CMP

22 Ga.Solid

Copper-Clad Steel

54.7 Ω/Mft.

Fluoropolymer 95% BareCopper Braid1.9 Ω/Mft.

Flexguard® PVCNatural

13.00 42.65 84 93 11050

100200500

1000

0.300.901.902.703.805.908.34

0.145 3.56 0.201 5.11

RG 62/U Type

Product Construction: Conductors: •Copper-cladsteelperASTMB-869

Insulation/Core: •Semi-solidpolyethylene(PE)design •Foamfluoropolymer(FEP)design

Shield: •Barecopperbraid

Jacket: •PremiumPVCcompound

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •SuitableforRFsignaltransmission •Computer/networks •SeeCoaxConnectorCrossReference,

pages 192-199

Page 121: Cross-Reference & Online Spec Sheets - Datasheet Archive

110

Electronics Coaxial Cable

RG 174/U Type

Product Construction: Conductors: •Copper-cladsteelperASTMB-869

Insulation/Core: •Solidpolyethylene(PE)design

Shield: •Tinnedorbarecopperbraid

Jacket: •PremiumPVCcompound

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •SuitableforRFsignaltransmission •SeeCoaxConnectorCrossReference,

pages 192-199

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

C1156RG 174/U Type 1354

26 Ga.(7/34)

Copper-Clad Steel

97.0 Ω/Mft.

Solid PE88% Tinned Copper Braid10.3 Ω/Mft.

Black PVC30.80 101.05 66 50 1

1050

100200500

1000

1.903.305.808.40

12.5021.2134.00

0.103 2.620.060 1.52

395027RG 174/U 1354

26 Ga.(7/34)

Copper-Clad Steel

93.0 Ω/Mft.

Solid PE88% Tinned Copper Braid

Shield10.7 Ω/Mft.

Black PVC30.80 101.05 66 50 1

1050

100200500

1000

1.903.305.808.40

12.5021.2134.00

0.059 0.139 0.110 2.82

Page 122: Cross-Reference & Online Spec Sheets - Datasheet Archive

111

Coaxial Cable Electronics

RG 213/U Type

Product Construction: Conductors: •CopperperASTMB-3

Insulation/Core: •Solidpolyethylene(PE)design

Shield: •Barecopperbraid

Jacket: •Premiumnon-contaminatingblackPVC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •SuitableforRFsignaltransmission •SeeCoaxConnectorCrossReference,

pages 192-199

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

C1176ARG 213/U TypeMIL-C-17G Type 1354

13 Ga.(7/21)

Bare Copper1.7 Ω/Mft.

Solid PE95% Bare

Copper Braid1.2 Ω/Mft.

Black PVC30.80 101.05 66 50 1

1050

100200500

1000

0.180.621.502.103.005.038.20

0.405 10.290.285 7.24

Page 123: Cross-Reference & Online Spec Sheets - Datasheet Archive

112

Electronics Coaxial Cable

Twinaxial Cables

Product Construction: Conductors: •CopperperASTMB-3 •TinnedcopperperASTMB-33

Insulation/Core: •Solidandfoampolyethylene(PE)

designs •Lo-Cap®polypropylene(PPE)design

Shield: •Tinnedcopperbraid •Flexfoil® shield

Jacket: •PremiumPVCcompound

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Applications: •ProgrammableLogicControllers(PLC) •Datatransmission •Broadcast •Computer •SeeCoaxConnectorCrossReference,

pages 192-199

CATALOG NUMBER

AWGSIZE

NOM. DCR

INSULATION MATERIAL

SHIELDCOVERAGE

NOM SHLD DCR

NOMINAL O.D.

NOMINALCAPACITANCE

VELOCITY OFPROPAGATION,

%

NOMINALIMPEDANCE,

Ω

NOMINALATTENUATION

INCHES mm INCHES mm pF/ft pF/m MHz dB/100'

C8000UL CL2 249880°C, 300V

20 Ga.(7/28)

(1) Tinned Copper,(1) Bare Copper

9.5 Ω/Mft.

Solid PECoded:

Natural, Natural

100% Flexfoil®

+90%Tinned Copper

Braid2.5 Ω/Mft.

Black PVC 15.50 50.86 66 100 11050

100200400

0.401.102.504.106.4010.20

0.330 8.38

0.022 0.56

C8001UL CL2, CMC(UL) CM 2464 258260°C, 300V

20 Ga.(7/28)TinnedCopper

9.5 Ω/Mft.

Solid PECoded:

Natural, Blue

100% Flexfoil®

+57%Tinned Copper

Braid4.1 Ω/Mft.

Blue PVC19.17 62.90 66 78 1

1050

100200400

0.602.105.007.5011.0016.00

0.020 0.51 0.242 6.15

C8014 266860°C, 30V

22 Ga.(19/34)Tinned Copper

15.0 Ω/Mft.

Lo-Cap® PPECoded:

Black, Yellow

100% Flexfoil®

+22 AWGTinned Copper

Drain Wire6.3 Ω/Mft.

Black PVC

8.80 28.87 78 150 11050

100200400

0.401.202.654.306.208.800.051 1.30 0.360 9.14

Page 124: Cross-Reference & Online Spec Sheets - Datasheet Archive

113

Electronics

Fire Alarm/Life Safety Cable 6

Index Page

Alarm and Security Solutions Guide 114-116

Multi-Conductor, Unshielded, Non-Plenum 117

Multi-Conductor, Unshielded, Non-Plenum (CSA) 118

Multi-Conductor, Shielded, Non-Plenum 119

Multi-Conductor, Shielded, Non-Plenum (CSA) 120

Multi-Conductor, Unshielded, Plenum 121-122

Multi-Conductor, Shielded, Plenum 123-124

Mid-Capacitance, Unshielded, Non-Plenum 125

Mid-Capacitance, Shielded, Non-Plenum 126

Mid-Capacitance, Unshielded, Plenum 127

Mid-Capacitance, Shielded, Plenum 128

Multi-Paired, Unshielded, Non-Plenum (CSA) 129

Fire alarm systems have expanded from a rather simple and unsophisticated business configured upon large, electro-mechanical devices to one relying upon the most modern technologies of microprocessor and chip technology.

More and more end users— industrial, commercial as well as consumer—are relying upon these emerging systems to protect both property and life. These systems are only as good as their weakest component, whether that component be a processor or interconnecting wire and cable.

It is General Cable’s charter that all products supplied for use in these and any other systems shall be constructed of only the finest available materials, and provide the service and assurance that the end user not only needs, but requires.

Aside from the quality materials used in these designs, specifiers and end users of Carol® Brand wire and cable products have come to expect that these cables are registered and certified with the leading regulatory agencies such as Underwriters Laboratories … and we haven’t let you down!

These designs have proven themselves in the area of fire system security over time; all are fabricated with solid, bare copper conductors and insulations and jackets of premium-grade PVC. Offered both with and without shields, the former to protect these critical circuits from noise, these cables will provide the latest in available technology for the system installer and contractor.

General Cable Carol® Brand products are conveniently packaged in 1000' or 500' Iengths to assist the installer.

Page 125: Cross-Reference & Online Spec Sheets - Datasheet Archive

114

General Cable’s Carol® Brand is the right solution for alarm and security wire and cable. Carol offers as broad an offering as anyone in the industry. Our Alarm and Security Solutions Guide makes it easier to specify and sell the right cables for every application in this ever-growing market.

There are five basic areas where alarm and security cables are used. General Cable has the right product to serve every application, including:

• Access Control

• Video Surveillance/CCTV

• Fire Alarm and Life Safety

• Home Theater and Burglar Alarms

• Data Communications

Our alarm and security cables offer solutions in all these major security applications markets, including:

• Commercial Buildings

• Residential Housing

• Business and Office Campus Environments

• Public Stadiums and Arenas

• Airport, Train, Bus and Other Transportation Hubs

• Schools, Colleges and Universities

The General Cable Alarm and Security Solutions Guide provides a quick and easy reference tool to identify every Carol® Brand cable for the appropriate alarm and security application. Whatever the security application need calls for, we have a cable that delivers the performance you need.

Carol® Brand Alarm & Security Solutions

Cable Solution Description

4EPL4S* 4 Shielded Elements Overall Jacket Access Control Plenum4EPL1S* 4 Elements 1 Shielded Overall Jacket Access Control Plenum4ERS4S** 4 Shielded Elements Overall Jacket Access Control Riser4ERS1S** 4 Elements 1 Shielded Overall Jacket Access Control RiserE2002S 22/2 Conductor Shielded RiserE2004S 22/4 Conductor Shielded RiserE2006S 22/6 Conductor Shielded RiserE2008S 22/8 Conductor Shielded RiserE2010S 22/10 Conductor Shielded RiserE2012S 22/12 Conductor Shielded RiserE2102S 22/2 Conductor Shielded PlenumE2104S 22/4 Conductor Shielded PlenumE2106S 22/6 Conductor Shielded PlenumE2108S 22/8 Conductor Shielded PlenumE2032S 18/2 Conductor Shielded RiserE2034S 18/4 Conductor Shielded RiserE2036S 18/6 Conductor Shielded RiserE2038S 18/8 Conductor Shielded Riser

Cable Solution Description

E2202S 18/2 Conductor Shielded PlenumE2204S 18/4 Conductor Shielded PlenumE2206S 18/6 Conductor Shielded PlenumE2208S 18/8 Conductor Shielded Plenum

Applications:Door Controllers Prox Sensors Key Pads Card Readers Gate Access

Carol® Brand Composite Access Control Cable – Plenum*(3) Multi-Conductors • (1) Multi-Pair • Overall Jacket60˚C 300 Volt (UL) & C(UL) Type CMP

Catalog Number

Overall Nominal OD Inch (mm)

Component No. Component Descriptions Conductors Color Code

Component Nominal OD

Inch (mm)

Insulation Thickness Inch (mm)

4EPL4S 0.430

1 4 Cond, 18 AWG, Shielded White, Black, Red, Green 0.180 (4.572) 0.008 (0.2032)

2 3 Pair, 22 AWG, Shielded

White & Green, Orange & Brown, Red & Black 0.195 (4.593) 0.008 (0.2032)

3 2 Cond, 22 AWG, Shielded Red, Black 0.125 (3.175) 0.008 (0.2032)

4 4 Cond, 22 AWG, Shielded White, Black, Red, Green 0.145 (3.683) 0.008 (0.2032)

4EPL1S 0.420

1 4 Cond, 18 AWG, Unshielded White, Black, Red, Green 0.180 (4.572) 0.008 (0.2032)

2 3 Pair, 22 AWG, Shielded

White & Green, Orange & Brown, Red & Black 0.195 (4.593) 0.008 (0.2032)

3 2 Cond, 22 AWG, Unshielded Red, Black 0.125 (3.175) 0.008 (0.2032)

4 4 Cond, 22 AWG, Unshielded White, Black, Red, Green 0.145 (3.683) 0.008 (0.2032)

Carol® Brand Composite Access Control Cable – Riser**(3) Multi-Conductors • (1) Multi-Pair • Overall Jacket60˚C 300 Volt (UL) & C(UL) Type CMR

Catalog Number

Overall Nominal OD

Inch (mm)

Component No. Component Descriptions Conductors Color Code

Component Nominal OD

Inch (mm)

Insulation Thickness Inch (mm)

4ERS4S 0.430

1 4 Cond, 18 AWG, Shielded White, Black, Red, Green 0.180 (4.572) 0.008 (0.2032)

2 3 Pair, 22 AWG, Shielded

White & Green, Orange & Brown, Red & Black 0.195 (4.593) 0.008 (0.2032)

3 2 Cond, 22 AWG, Shielded Red, Black 0.125 (3.175) 0.008 (0.2032)

4 4 Cond, 22 AWG, Shielded White, Black, Red, Green 0.145 (3.683) 0.008 (0.2032)

4ERS1S 0.420

1 4 Cond, 18 AWG, Unshielded White, Black, Red, Green 0.180 (4.572) 0.008 (0.2032)

2 3 Pair, 22 AWG, Shielded

White & Green, Orange & Brown, Red & Black 0.195 (4.593) 0.008 (0.2032)

3 2 Cond, 22 AWG, Unshielded Red, Black 0.125 (3.175) 0.008 (0.2032)

4 4 Cond, 22 AWG, Unshielded White, Black, Red, Green 0.145 (3.683) 0.008 (0.2032)

Access Control

Many cables also available inARMORED

CONSTRUCTIONSfor easy plenum

installations

Surge

Rex/Spare

Door Contact

Card Reader

Lock Power

PowerSupply

Access Control Panel

PC

Page 126: Cross-Reference & Online Spec Sheets - Datasheet Archive

115

Cable Solution DescriptionE1502S 18/2 Conductor Riser FPLRE1504S 18/4 Conductor Riser FPLRE1522S 14/2 Conductor Riser FPLRE1524S 14/4 Conductor Riser FPLRE2502S 18/2 Conductor Shielded Riser FPLRE2504S 18/4 Conductor Shielded Riser FPLRE2532S 14/2 Conductor Shielded Riser FPLRE2534S 14/4 Conductor Shielded Riser FPLRE3502S 18/2 Conductor Plenum FPLPE3504S 18/4 Conductor Plenum FPLPE3522S 14/2 Conductor Plenum FPLPE3524S 14/4 Conductor Plenum FPLP

Cable Solution DescriptionE3602S 18/2 Conductor Shielded Plenum FPLPE3604S 18/4 Conductor Shielded Plenum FPLPE3622S 14/2 Conductor Shielded Plenum FPLPE3624S 14/4 Conductor Shielded Plenum FPLP

CATV/MATV/DBS RG 59, RG 6 and RG 11 RatingsCable Solution DescriptionC3521 RG 6/U 18/1 FL + 95% TC CL2PC3523 RG 6 SBC/Foil/61% TC Braid PlenumC3524 RG 6 CCS/Foil/60% AL Braid PlenumC3525 RG 6 CCS/Quad 60/40% AL Braid PlenumC5761 RG 6 SBC Foil/95% BC Braid CATV/CMC5775 RG 6 CCS/Foil/60% AL Braid CATV/CMC5785 RG 6 CCS/Quad 60/40% AL Braid CATV/CMC5886 RG 6 CCS/Foil/60% AL Braid CATVR/CMRC5889 RG 6 CCS/Quad 60/40% AL Braid CATVR/CMR C3528 RG 11 CCS/Foil/60%/AL Braid CATV/CMP PlenumC5039 RG 11 CCS/Foil/60%/AL Braid CATV/CMC5043 RG 11/U CCS Burial FL 60% ALC5044 RG 11/U CCS Quad Shield CL2/CMC1135 RG 59/U CCS 95% BC Braid CMC3500 RG 59 CCS/95% BC Braid PlenumC3526 RG 59/U CCS AMA/80% AL Braid CLP2/CMP

HDTV/SDI—Interconnect Cables RG 59, RG 6 and RG 11 RatingsCable Solution Description395011 RG 6 SBC/Foil/95% TC Braid CMR395014 RG 6/U 18/1 SBC Quad Shield 60%/40% CMR495025 RG 6/U 18 AWG SBC 95% Dual Foil TC Braid CMP Plenum395025 RG 59 SBC/Foil/95% TC Braid CMR395031 RG 59 Single/Miniature/Foil/95% TC Braid CMR495023 RG 59/U SBC/Foil/95% TC Braid CMP Plenum

CCTV RG 59 and RG 11 RatingsCable Solution DescriptionC8029 RG 6 + 18/2 Unshielded CATV/CMC8031 RG 6/U SBC/95% + 18/2 Unshielded Pair CMP Plenum495035 RG 6/U 18 AWG SBC 95% BC CMP Plenum395058 RG 11 SBC/95% BC Braid CM495015 RG 11 SBC/95% BC Braid CMP PlenumC1103 RG 59 BC/95% BC Braid CATV/CMC1142 RG 59 SBC/95% BC Braid CATV/CMC8025 RG 59/U STR (7/30) BC/95% + 22/2 SH Pair CCTV/CMC8027 RG 59 + 18/2 Shielded CATV/CMC8028 RG 59 + 18/2 Unshielded CATV/CMC8030 RG 59/U SBC/95% + 18/2 Unshielded Pair CCTV Plenum495028 RG 59 SBC/95% BC Braid CMP Plenum

Low Skew - 4 Pair UTP Cables for RGB VideoCable Solution DescriptionE3842S Low Skew 24/4 UTP CMP for RGB Video E1842S Low Skew 24/4 UTP CMR for RGB Video E3843S Low Skew 23/4 UTP CMP for RGB Video E1843S Low Skew 23/4 UTP CMR for RGB Video

Applications:Smoke Detectors Strobes/Sirens Pull Stations Microprocessor/ Addressable Controlled Systems

Applications:CCTV Satellites Digital Video Analog Video Switchers/Multiplexers Digital Recorders

Fire Alarm and Life Safety

Video Surveillance/CCTV

Power Supply

BNC Patch Panel

BNC Patch Panel

Monitor

Remote Keypad

Multiplexer

Recorder

Video Camera

CDU

Surge

PowerSupply

Strobe

Siren/Horn

Smoke Detector

Pull StationPUSH PULL

FIREFIRE

Fire Control Panel

Page 127: Cross-Reference & Online Spec Sheets - Datasheet Archive

116

Cat 6 Pull-Pac® IIStandard packaging: 1000' Pull-Pac® II

Pull-Pac® II

Jacket ColorCMR (Non-

Plenum)CMP

(Plenum)

Blue CR6.30.07 CP6.30.07

White CR6.30.02 CP6.30.02

Gray CR6.30.10 CP6.30.10

Green CR6.30.06 CP6.30.06

Yellow CR6.30.05 CP6.30.05

Red CR6.30.03 CP6.30.03

Cat 5e Pull-Pac® IIStandard packaging: 1000' Pull-Pac® II

Pull-Pac® II

Jacket ColorCMR (Non-

Plenum)CMP

(Plenum)

Blue CR5.30.07 CP5.30.07

White CR5.30.02 CP5.30.02

Gray CR5.30.10 CP5.30.10

Green CR5.30.06 CP5.30.06

Yellow CR5.30.05 CP5.30.05

Red CR5.30.03 CP5.30.03

Cat 6 Spool-Pac®

Standard packaging: 1000' Spool-Pac®

Spool-Pac®

Jacket ColorCMR (Non-

Plenum)CMP

(Plenum)

Blue CR6.A3.07 CP6.A3.07

White CR6.A3.02 CP6.A3.02

Gray CR6.A3.10 CP6.A3.10

Green CR6.A3.06 CP6.A3.06

Yellow CR6.A3.05 CP6.A3.05

Red CR6.A3.03 CP6.A3.03

Cat 5e Spool-Pac®

Standard packaging: 1000' Spool-Pac®

Spool-Pac®

Jacket ColorCMR (Non-

Plenum)CMP

(Plenum)

Blue CR5.A3.07 CP5.A3.07

White CR5.A3.02 CP5.A3.02

Gray CR5.A3.10 CP5.A3.10

Green CR5.A3.06 CP5.A3.06

Yellow CR5.A3.05 CP5.A3.05

Red CR5.A3.03 CP5.A3.03

Cable Solution Description

E1002S 22/2 Conductor RiserE1004S 22/4 Conductor RiserC4408 22/2 Solid Conductor CMR/CMXC4408ST 22/2 Stranded Conductor CMR/CMXC4412 22/4 Solid Conductor Solid CMR/CMXC4412ST 22/4 Stranded Conductor CMR/CMXC4408.86.XX 22/2 Solid Conductor CM/CMX*C4408ST.86.XX 22/2 Stranded Conductor CM/CMX*C4412.86.XX 22/4 Solid Conductor CM/CMX*C4412ST.86.XX 22/4 Stranded Conductor CM/CMX*E1006S 22/6 Conductor RiserE1008S 22/8 Conductor RiserE1032S 18/2 Conductor RiserE1034S 18/4 Conductor RiserE1042S 16/2 Conductor RiserE1044S 16/4 Conductor RiserE1052S 14/2 Conductor RiserE1054S 14/4 Conductor RiserE1062S 12/2 Conductor RiserE1064S 12/4 Conductor Riser

*Available Colors for Burglar Alarm Coil Packs XX= White Gray Green Beige Yellow Dark Blue

Cable Solution Description

C1000 Command® Series Twisted Pair Speaker, 22/2, 7x30 Stranding, 500' ReelsC1001 Command Series Twisted Pair Speaker, 20/2, 7x28 Stranding, 500' ReelsC1002 Command Series Twisted Pair Speaker, 18/2, 7x26 Stranding, 500' ReelsC1003 Command Series Twisted Pair Speaker, 16/2, 19x29 Stranding, 500' ReelsC1004 Command Series Twisted Pair Speaker, 14/2, 42x30 Stranding, 500' ReelsC1005 Command Series Twisted Pair Speaker, 12/2, 65x30 Stranding, 500' ReelsC1362 22/2 Conductor Zip (not for inwall use)C1357 18/2 Conductor Zip (not for inwall use)C1458 16/2 Conductor Zip CL2C1461 14/2 Conductor Zip CL2C1463 12/2 Conductor Zip CL2C1702 14/2 Command Series Home Grade SpeakerC1703 14/4 Command Series Home Grade SpeakerC1704 16/2 Command Series Home Grade SpeakerC1705 16/4 Command Series Home Grade SpeakerC1800 Command Series “High Def” Speaker Type NEC, 12/2, 105x32 Stranding, 500' ReelsC1801 Command Series “High Def” Speaker Type NEC, 12/4, 105x32 Stranding, 500' ReelsC1802 Command Series “High Def” Speaker Type NEC, 14/2, 105x34 Stranding, 500' BoxesC1803 Command Series “High Def” Speaker Type NEC, 14/4, 105x34 Stranding, 500' ReelsC1804 Command Series “High Def” Speaker Type NEC, 16/2, 65x34 Stranding, 500' BoxesC1805 Command Series “High Def” Speaker Type NEC, 16/4, 65x34 Stranding, 500' Boxes395031X3 23/3 Command Series RGB Cables, Solid BC, Foam PE, Dual Foil + 95% TC Braid395031X5 23/5 Command Series RGB Cables, Solid BC, Foam PE, Dual Foil + 95% TC Braid

Applications:Intercoms PA Systems Sound Systems Emergency Phones Speakers Burglar Alarms Home Theater

Applications:Telephones Cat 5e and 6 Connections Networking Workstations Video Conferencing Telco Closets Home Automation IP Cameras

Home Theater and Burglar Alarms

Burglar

Alarm Cable

in 500' Coil

Packs*Oxygen-Free

+ ETP

High-Performance

Home Theater

Cables

Carol® Brand Helix/Hi-Temp® Data Communications

Page 128: Cross-Reference & Online Spec Sheets - Datasheet Archive

117

Fire Alarm/Life Safety Cable Electronics

Multi-Conductor, Unshielded, Non-Plenum NEC Type FPLR

Product Construction: Conductor: •22thru12AWGfullyannealedsolidbare

copper per ASTM B-3

Insulation: •Premium-grade,coIor-codedS-RPVC •Colorcode:Seechartbelow

Jacket: •Premium-grade,redPVC •Suitableforusefrom-20°Cto+75°C •Roundconstructionshavesequential

footage markings to facilitate installation •Includesripcordonroundconstructions

Applications: •Wiringoffirealarms •Smokedetectors •Voicecommunications •Burglaralarms •Fireprotectivecircuits •Suggestedvoltagerating:300volts

Compliances: •NECArticle760TypeFPLR

(UL:75°C,300V) •CaliforniaStateFireMarshallApproved •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL1666FlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Color Code ChartNO. OFCOND. COLOR

1 Black

2 Red

3 Brown

4 Blue

5 Orange

6 Yellow

7 Violet

8 Gray

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS

NOM. JACKETWALL NOMINAL O.D.

INCHES mm INCHES mm INCHES mm

22 AWG CONDUCTORSE1482S 2 22 Solid 0.010 0.25 0.015 0.38 0.121 3.07

E1484S 4 22 Solid 0.010 0.25 0.015 0.38 0.140 3.56

E1486S 6 22 Solid 0.010 0.25 0.015 0.38 0.168 4.27

18 AWG CONDUCTORSE1502S 2 18 Solid 0.010 0.25 0.015 0.38 0.150 3.81

E1503S 3 18 Solid 0.010 0.25 0.015 0.38 0.160 4.06

E1504S 4 18 Solid 0.010 0.25 0.015 0.38 0.175 4.45

E1505S 5 18 Solid 0.010 0.25 0.015 0.38 0.193 4.90

E1506S 6 18 Solid 0.010 0.25 0.015 0.38 0.210 5.33

E1508S 8 18 Solid 0.010 0.25 0.015 0.38 0.230 5.84

16 AWG CONDUCTORSE1512S 2 16 Solid 0.010 0.25 0.015 0.38 0.172 4.37

E1514S 4 16 Solid 0.010 0.25 0.015 0.38 0.202 5.13

14 AWG CONDUCTORSE1522S 2 14 Solid 0.013 0.33 0.015 0.38 0.210 5.33

E1524S 4 14 Solid 0.013 0.33 0.015 0.38 0.248 6.30

12 AWG CONDUCTORSE1532S 2 12 Solid 0.013 0.33 0.015 0.38 0.244 6.20

E1534S 4 12 Solid 0.013 0.33 0.015 0.38 0.288 7.32

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS NOMINAL O.D.

INCHES mm INCHES mm

DUPLEX PARALLEL, RIBBED FOR POLARITYE2402S 2 18 Solid 0.032 0.81 0.105 x 0.210 2.67 x 5.33

E2404S 2 16 Solid 0.032 0.81 0.115 x 0.230 2.92 x 5.84

E2406S 2 14 Solid 0.032 0.81 0.126 x 0.260 3.20 x 6.60

Page 129: Cross-Reference & Online Spec Sheets - Datasheet Archive

118

Electronics Fire Alarm/Life Safety Cable

Multi-Conductor, Unshielded, Non-Plenum CSA FAS 105, FPL (UL), NEC Type PLTC

Product Construction: Conductor: •22thru12AWGfullyannealedsolidbare

copper per ASTM B-3

Insulation: •Premium-gradePVC •Colorcode:Seepage229fortheCSA

Fire Alarm Color Code Chart

Jacket: •Premium-grade,redPVC;brownasan

option •Temperaturerange:-20°Cto+105°C •TRU-Mark® print legend contains

footage markings from 1000' to 0'

Applications: •Wiringoffirealarms •Smokealarms •Voicecommunications •Burglaralarms •Fireprotectivecircuits •Suggestedvoltagerating:300volts

Compliances: •NECArticle725PLTC(UL:105˚C,300V) •NECArticle760TypeFPL

(UL:105˚C,300V) •CSAFAS105(CSA:105˚C,300V) •C22.2No.208-03(R2008) •DesignedtomeetUL70,000BTU

Vertical Tray Flame Test •PassesCSAFT-4VerticalFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS

NOM. JACKETWALL NOMINAL O.D.

INCHES mm INCHES mm INCHES mm

C4300A 6 22 Solid 0.012 0.30 0.042 1.07 0.232 5.89

C4301A 15 22 Solid 0.012 0.30 0.042 1.07 0.316 8.03

C4302A 20 22 Solid 0.012 0.30 0.042 1.07 0.346 8.79

C4304A 2 18 Solid 0.015 0.38 0.042 1.07 0.225 5.71

C4305A 3 18 Solid 0.015 0.38 0.042 1.07 0.236 5.99

C4306A 4 18 Solid 0.015 0.38 0.042 1.07 0.255 6.47

C4307A 5 18 Solid 0.015 0.38 0.042 1.07 0.274 6.96

C4308A 6 18 Solid 0.015 0.38 0.042 1.07 0.296 7.52

C4309A 7 18 Solid 0.015 0.38 0.042 1.07 0.296 7.52

C4310A 8 18 Solid 0.015 0.38 0.042 1.07 0.317 8.05

C4312A 9 18 Solid 0.015 0.38 0.042 1.07 0.339 8.61

C4313A 10 18 Solid 0.015 0.38 0.042 1.07 0.366 9.30

C4314A 11 18 Solid 0.015 0.38 0.042 1.07 0.366 9.30

C4315A 15 18 Solid 0.015 0.38 0.053 1.35 0.437 11.10

C4316A 20 18 Solid 0.015 0.38 0.053 1.35 0.480 12.19

C4317A 21 18 Solid 0.015 0.38 0.053 1.35 0.480 12.19

C4318A 30 18 Solid 0.015 0.38 0.053 1.35 0.558 14.17

C4321A 2 16 Solid 0.015 0.38 0.042 1.07 0.246 6.25

C4322A 3 16 Solid 0.015 0.38 0.042 1.07 0.258 6.55

C4323A 4 16 Solid 0.015 0.38 0.042 1.07 0.280 7.11

C4349A 5 16 Solid 0.015 0.38 0.042 1.07 0.302 7.67

C4324A 2 14 Solid 0.015 0.38 0.042 1.07 0.272 6.91

C4325A 3 14 Solid 0.015 0.38 0.042 1.07 0.286 7.26

C4326A 4 14 Solid 0.015 0.38 0.042 1.07 0.311 7.90

C4327A 2 12 Solid 0.020 0.51 0.042 1.07 0.326 8.28

Page 130: Cross-Reference & Online Spec Sheets - Datasheet Archive

119

Fire Alarm/Life Safety Cable Electronics

Multi-Conductor, Shielded, Non-Plenum NEC Type FPLR

Product Construction: Conductor: •22thru12AWGfullyannealedsolidbare

copper per ASTM B-3

Insulation: •Premium-grade,coIor-codedS-RPVC •Colorcode:Seechartbelow

Shield: •OverallFlexfoil® polyester supported

aluminum foil •Strandedtinnedcopperdrainwire

Jacket: •Premium-grade,redPVC •Temperaturerange:-20°Cto+75°C •Sequentialfootagemarkingstofacilitate

installation •Includesripcord

Applications: •Wiringoffirealarms •Smokealarms •Voicecommunications •Burglaralarms •Fireprotectivecircuits •Suggestedvoltagerating:300volts

Compliances: •NECArticle760TypeFPLR

(UL:75°C,300V) •CaliforniaStateFireMarshallApproved •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL1666FlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS

NOM. JACKETWALL NOMINAL O.D.

INCHES mm INCHES mm INCHES mm

22 AWG CONDUCTORS

E2482S 2 22 Solid 0.010 0.25 0.015 0.38 0.126 3.20

E2484S 4 22 Solid 0.010 0.25 0.015 0.38 0.145 3.68

18 AWG CONDUCTORS

E2502S 2 18 Solid 0.010 0.25 0.015 0.38 0.158 4.01

E2503S 3 18 Solid 0.010 0.25 0.015 0.38 0.165 4.19

E2504S 4 18 Solid 0.010 0.25 0.015 0.38 0.183 4.65

E2506S 6 18 Solid 0.010 0.25 0.015 0.38 0.216 5.49

E2508S 8 18 Solid 0.010 0.25 0.015 0.38 0.235 5.97

16 AWG CONDUCTORS

E2522S 2 16 Solid 0.010 0.25 0.015 0.38 0.180 4.57

E2524S 4 16 Solid 0.010 0.25 0.015 0.38 0.210 5.33

14 AWG CONDUCTORS

E2532S 2 14 Solid 0.013 0.33 0.015 0.38 0.218 5.54

E2534S 4 14 Solid 0.013 0.33 0.015 0.38 0.253 6.43

12 AWG CONDUCTORS

E2542S 2 12 Solid 0.013 0.33 0.015 0.38 0.252 6.40

E2544S 4 12 Solid 0.013 0.33 0.015 0.38 0.293 7.44

Color Code ChartNO. OFCOND. COLOR

1 Black2 Red3 Brown4 Blue5 Orange6 Yellow7 Violet8 Gray

Page 131: Cross-Reference & Online Spec Sheets - Datasheet Archive

120

Electronics Fire Alarm/Life Safety Cable

Multi-Conductor, Shielded, Non-Plenum CSA FAS 105, FPL (UL), NEC Type PLTC

Product Construction: Conductor: •18-12AWGfullyannealed,solidbare

copper per ASTM B-3

Insulation: •Premium-grade,coIor-codedPVC •Colorcode:Seepage229fortheCSA

Fire Alarm Color Code Chart

Shield: •100%Flexfoil® aluminum/polyester with

25%overlap,foilfacingout •Strandedtinnedcopperdrainwire

Jacket: •Premium-grade,redPVC;brownasan

option •Temperaturerange:-20°Cto+105°C •TRU-Mark® print legend contains

footage markings from 1000' to 0'

Applications: •Wiringoffirealarms •Smokealarms •Voicecommunications •Burglaralarms •Fireprotectivecircuits •Suggestedvoltagerating:300volts

Compliances: •NECArticle725PLTC(UL:105˚C,300V) •NECArticle760TypeFPL

(UL:105˚C,300V) •CSAFAS105(CSA:105˚C,300V) •C22.2No.208-03(R2008) •DesignedtomeetUL70,000BTU

Vertical Tray Flame Test •PassesCSAFT-4VerticalFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

DRAINWIREAWG

NOM. INSULATIONTHICKNESS

NOM. JACKETTHICKNESS NOMINAL O.D.

INCHES mm INCHES mm INCHES mm

C4334A 2 18 Solid 22 0.015 0.38 0.042 1.07 0.230 5.84

C4335A 3 18 Solid 22 0.015 0.38 0.042 1.07 0.241 6.12

C4336A 4 18 Solid 22 0.015 0.38 0.042 1.07 0.260 6.60

C4337A 5 18 Solid 22 0.015 0.38 0.042 1.07 0.279 7.09

C4338A 6 18 Solid 22 0.015 0.38 0.042 1.07 0.301 7.65

C4339A 7 18 Solid 22 0.015 0.38 0.042 1.07 0.301 7.65

C4340A 8 18 Solid 22 0.015 0.38 0.042 1.07 0.322 8.18

C4341A 9 18 Solid 22 0.015 0.38 0.042 1.07 0.344 8.74

C4342A 10 18 Solid 22 0.015 0.38 0.042 1.07 0.371 9.42

C4343A 30 18 Solid 22 0.015 0.38 0.053 1.35 0.563 14.30

C4344A 2 16 Solid 22 0.015 0.38 0.042 1.07 0.251 6.37

C4345A 3 16 Solid 22 0.015 0.38 0.042 1.07 0.263 6.68

C4346A 4 16 Solid 22 0.015 0.38 0.042 1.07 0.285 7.24

C4350A 5 16 Solid 22 0.015 0.38 0.042 1.07 0.307 7.80

C4347A 2 14 Solid 16 0.015 0.38 0.042 1.07 0.277 7.04

C4348A 2 12 Solid 16 0.020 0.51 0.042 1.07 0.331 8.41

Page 132: Cross-Reference & Online Spec Sheets - Datasheet Archive

121

Fire Alarm/Life Safety Cable Electronics

Multi-Conductor, Unshielded, Plenum NEC Type FPLP

Product Construction: Conductor: •22thru12AWGfullyannealedsolidbare

copper per ASTM B-3

Insulation: •Premium-grade,coIor-codedFlexguard®

PVC •Colorcode:Seechartbelow

Jacket: •Premium-grade,redFlexguard® PVC •Temperaturerange:0°Cto+75°C •Sequentialfootagemarkingstofacilitate

installation •Includesripcord

Applications: •Wiringoffirealarms •Smokedetectors •Voicecommunications •Burglaralarms •Fireprotectivecircuits •Suggestedvoltagerating:300volts

Compliances: •NECArticle760TypeFPLP

(UL:75°C,300V) •CaliforniaStateFireMarshallApproved •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Color Code ChartNO. OFCOND. COLOR

1 Black

2 Red

3 Brown

4 Blue

5 Orange

6 Yellow

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS

NOM. JACKETWALL NOMINAL O.D.

INCHES mm INCHES mm INCHES mm

22 AWG CONDUCTORS

E3482S 2 22 Solid 0.010 0.25 0.015 0.38 0.121 3.07

E3484S 4 22 Solid 0.010 0.25 0.015 0.38 0.137 3.47

18 AWG CONDUCTORS

E3502S 2 18 Solid 0.010 0.25 0.015 0.38 0.155 3.81

E3503S 3 18 Solid 0.010 0.25 0.015 0.38 0.160 4.06

E3504S 4 18 Solid 0.010 0.25 0.015 0.38 0.175 4.45

E3506S 6 18 Solid 0.010 0.25 0.015 0.38 0.211 5.36

16 AWG CONDUCTORS

E3512S 2 16 Solid 0.010 0.25 0.015 0.38 0.172 4.37

E3514S 4 16 Solid 0.010 0.25 0.015 0.38 0.202 5.13

14 AWG CONDUCTORS

E3522S 2 14 Solid 0.012 0.30 0.015 0.38 0.205 5.21

E3524S 4 14 Solid 0.012 0.30 0.015 0.38 0.243 6.17

12 AWG CONDUCTORS

E3532S 2 12 Solid 0.012 0.30 0.015 0.38 0.244 6.20

E3534S 4 12 Solid 0.012 0.30 0.015 0.38 0.284 7.21

Page 133: Cross-Reference & Online Spec Sheets - Datasheet Archive

122

Electronics Fire Alarm/Life Safety Cable

Multi-Conductor, Unshielded, Plenum NECTypeFPLP,PVDFJacketed

Product Construction Conductor: •18thru12AWGfullyannealedsolidbare

copper to ASTM B-3

Insulation: •Premium-grade,coIor-codedFlexguard®

PVC •Colorcode:Seechartbelow

Jacket: •Fluoropolymer,red •Temperaturerange:-10°Cto+75°C •Includesripcord

Applications: •Firealarmsystems •Voicecommunications •Smokedetectors •Pullboxes •Suggestedvoltagerating:300volts

Compliances: •NECArticle760TypeFPLP

(UL:75°C,300V) •CaliforniaStateFireMarshallApproved •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •Abrasion-,chemical-andwater-resistant

jacket •Sequentiallyfootagemarked

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFCOND

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM.*C-CCAP. pF/ftIN mm IN mm IN mm

C3200 2 18 Solid 0.010 0.23 0.010 0.25 0.140 3.56 29.0

C3201 4 18 Solid 0.010 0.23 0.010 0.25 0.156 3.96 29.0

C3210 2 16 Solid 0.010 0.23 0.010 0.25 0.133 3.38 31.0

C3211 4 16 Solid 0.010 0.23 0.010 0.25 0.186 4.72 31.0

C3220 2 14 Solid 0.013 0.31 0.010 0.25 0.170 4.32 31.0

C3223 4 14 Solid 0.013 0.31 0.010 0.25 0.224 5.69 31.0

C3224 2 12 Solid 0.013 0.31 0.010 0.25 0.194 4.93 35.0

C3225 4 12 Solid 0.013 0.31 0.010 0.25 0.261 6.63 35.0

*Capacitance between conductors

Color Code ChartNO. OFCOND. COLOR

1 Black

2 Red

3 Brown

4 Blue

Page 134: Cross-Reference & Online Spec Sheets - Datasheet Archive

123

Fire Alarm/Life Safety Cable Electronics

Multi-Conductor, Shielded, Plenum NEC Type FPLP

Product Construction: Conductor: •22thru12AWGfullyannealedsolidbare

copper per ASTM B-3

Insulation: •Premium-grade,coIor-codedFlexguard®

PVC •Colorcode:Seechartbelow

Shield: •OverallFlexfoil® polyester supported

aluminum foil •Strandedtinnedcopperdrainwire

Jacket: •Premium-grade,redFlexguard® PVC •Suitableforusefrom0°Cto+75°C •Sequentialfootagemarkingstofacilitate

installation •Includesripcord

Applications: •Wiringoffirealarms •Smokedetectors •Voicecommunications •Burglaralarms •Fireprotectivecircuits •Suggestedvoltagerating:300volts

Compliances: •NECArticle760TypeFPLP

(UL:75°C,300V) •CaliforniaStateFireMarshallApproved •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Packaging: •PleasecontactCustomerServicefor

packaging and color optionsColor Code Chart

NO. OFCOND. COLOR

1 Black

2 Red

3 Brown

4 Blue

5 Orange

6 Yellow

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS

NOM. JACKETWALL NOMINAL O.D.

INCHES mm INCHES mm INCHES mm

22 AWG CONDUCTORS

E3542S 2 22 Solid 0.010 0.25 0.015 0.38 0.126 3.20

18 AWG CONDUCTORS

E3602S 2 18 Solid 0.010 0.25 0.015 0.38 0.158 4.01

E3603S 3 18 Solid 0.010 0.25 0.015 0.38 0.165 4.19

E3604S 4 18 Solid 0.010 0.25 0.015 0.38 0.183 4.65

E3606S 6 18 Solid 0.010 0.25 0.015 0.38 0.216 5.49

16 AWG CONDUCTORS

E3612S 2 16 Solid 0.010 0.25 0.015 0.38 0.180 4.57

E3614S 4 16 Solid 0.010 0.25 0.015 0.38 0.210 5.33

14 AWG CONDUCTORS

E3622S 2 14 Solid 0.012 0.30 0.015 0.38 0.210 5.33

E3624S 4 14 Solid 0.012 0.30 0.015 0.38 0.248 6.30

12 AWG CONDUCTORS

E3632S 2 12 Solid 0.012 0.30 0.015 0.38 0.252 6.40

E3634S 4 12 Solid 0.012 0.30 0.015 0.38 0.300 7.62

Page 135: Cross-Reference & Online Spec Sheets - Datasheet Archive

124

Electronics Fire Alarm/Life Safety Cable

Multi-Conductor, Shielded, Plenum NECTypeFPLP,PVDFJacketed

Product Construction Conductor: •18thru12AWGfullyannealedsolidbare

copper per ASTM B-3

Insulation: •Premium-grade,coIor-codedFlexguard®

PVC •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester foil,

25%overlap,minimum •Strandedtinnedcopperdrainwire

Jacket: •Fluoropolymer,red •Temperaturerange:-10°Cto+75°C •Includesripcord

Applications: •Firealarmsystems •Voicecommunications •Smokedetectors •Pullboxes •Suggestedvoltagerating:300volts

Compliances: •NECArticle760TypeFPLP

(UL:75°C,300V) •CaliforniaStateFireMarshallApproved

Features: •Abrasion-,chemical-resistantjacket •Sequentiallyfootagemarked

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Color Code ChartNO. OFCOND. COLOR

1 Black

2 Red

3 Brown

4 Blue

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM.INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOMINAL CAP. *pF/ft

INCHES mm INCHES mm INCHES mm A B

C3260 2 18 Solid 0.010 0.25 0.010 0.25 0.149 3.78 50.5 90.8

C3261 4 18 Solid 0.010 0.25 0.010 0.25 0.168 4.27 44.5 80.0

C3270 2 16 Solid 0.010 0.25 0.010 0.25 0.169 4.29 58.0 104.0

C3271 4 16 Solid 0.010 0.25 0.010 0.25 0.194 4.93 50.0 90.0

C3280 2 14 Solid 0.013 0.33 0.010 0.25 0.214 5.44 55.5 100.0

C3284 4 14 Solid 0.013 0.33 0.010 0.25 0.245 6.22 48.0 87.0

C3282 2 12 Solid 0.013 0.33 0.010 0.25 0.234 5.94 65.0 116.0

C3283 4 12 Solid 0.013 0.33 0.010 0.25 0.284 7.21 55.0 99.0

*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield

Page 136: Cross-Reference & Online Spec Sheets - Datasheet Archive

125

Fire Alarm/Life Safety Cable Electronics

Mid-Capacitance, Unshielded, Non-Plenum NEC Type FPL for Microprocessor-Controlled Systems

Product Construction: Conductor: •18thru12AWGfullyannealedsolidbare

copper per ASTM B-3

Insulation: •Premium-grade,coIor-coded

polypropylene •Colorcode:Seechartbelow

Jacket: •PVC,red •Temperaturerange:-20°Cto+60°C

Applications: •Addressablefirealarmsystems •Firealarmsystems •Voicecommunications •Smokedetectors •Pullboxes •Suggestedvoltagerating:300volts

Compliances: •NECArticle760TypeFPL

(UL:60°C,300V) •CaliforniaStateFireMarshallApproved •RoHSCompliantDirective2002/95/EC •PassesUL70,000BTUVerticalTray

Flame Test

Features: •RedPVCjacketforeasycriticalcircuit

identification

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Color Code ChartNO. OFCOND. COLOR

1 Black

2 Red

3 Brown

4 Blue

CATALOG NUMBER

NO. OFCOND

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM.*C-CCAP. pF/ftIN mm IN mm IN mm

C0471 2 18 Solid 0.014 0.36 0.020 0.51 0.177 4.50 16.5

C0485 4 18 Solid 0.014 0.36 0.020 0.51 0.205 5.21 16.5

C0473 2 16 Solid 0.016 0.41 0.020 0.51 0.206 5.23 17.5

C0486 4 16 Solid 0.016 0.41 0.020 0.51 0.240 6.10 17.5

C0491 2 14 Solid 0.018 0.46 0.020 0.51 0.240 6.10 18.0

C0492 2 12 Solid 0.020 0.51 0.020 0.51 0.282 7.16 19.0

*Capacitance between conductors

Page 137: Cross-Reference & Online Spec Sheets - Datasheet Archive

126

Electronics Fire Alarm/Life Safety Cable

Mid-Capacitance, Shielded, Non-Plenum NEC Type FPL for Microprocessor-Controlled Systems

Product Construction: Conductor: •18thru12AWGfullyannealedsolidbare

copper per ASTM B-3

Insulation: •Premium-grade,coIor-coded

polypropylene •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester,

25%overlap,minimum •Strandedtinnedcopperdrainwire

Jacket: •PVC,red •Temperaturerange:0°Cto+60°C

Applications: •Addressablefirealarmsystems •Firealarmsystems •Voicecommunications •Smokedetectors •Pullboxes •Suggestedvoltagerating:300volts

Compliances: •NECArticle760TypeFPL

(UL:60°C,300V) •CaliforniaStateFireMarshallApproved •RoHSCompliantDirective2002/95/EC •PassesUL70,000BTUVerticalTray

Flame Test

Features: •RedPVCjacketforeasycriticalcircuit

identification

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Color Code ChartNO. OFCOND. COLOR

1 Black

2 Red

3 Brown

4 Blue

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM.INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOMINAL CAP. *pF/ft

INCHES mm INCHES mm INCHES mm A B

C0472 2 18 Solid 0.014 0.36 0.020 0.51 0.182 4.88 27.0 49.0

C0494 4 18 Solid 0.014 0.36 0.020 0.51 0.210 5.33 24.5 44.0

C0474 2 16 Solid 0.016 0.41 0.020 0.51 0.214 5.44 29.0 52.0

C0495 4 16 Solid 0.016 0.41 0.020 0.51 0.246 6.25 26.0 46.5

C0475 2 14 Solid 0.018 0.46 0.020 0.51 0.245 6.22 31.0 55.5

C0496 4 14 Solid 0.018 0.46 0.020 0.51 0.287 7.29 27.5 49.5

C0476 2 12 Solid 0.020 0.51 0.020 0.51 0.287 7.29 33.0 60.0

C0497 4 12 Solid 0.020 0.51 0.020 0.51 0.337 8.56 29.0 52.5

*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield

Page 138: Cross-Reference & Online Spec Sheets - Datasheet Archive

127

Fire Alarm/Life Safety Cable Electronics

Mid-Capacitance, Unshielded, Plenum NEC Type FPLP for Microprocessor-Controlled Systems

Product Construction: Conductor: •18thru12AWGfullyannealedsolidbare

copper per ASTM B-3

Insulation: •Premium-grade,coIor-coded

fluoropolymer •Colorcode:Seechartbelow

Jacket: •Premium-grade,redFlexguard® PVC •Temperaturerange:0°Cto+75°C •Includesripcord

Applications: •Addressablefirealarmsystems •Firealarmsystems •Voicecommunications •Smokedetectors •Pullboxes •Suggestedvoltagerating:300volts

Compliances: •NECArticle760TypeFPLP

(UL:75°C,300V) •CaliforniaStateFireMarshallApproved •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •RedPVCjacketforeasycriticalcircuit

identification

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Color Code ChartNO. OFCOND. COLOR

1 Black

2 Red

3 Brown

4 Blue

CATALOG NUMBER

NO. OFCOND

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM.*C-CCAP. pF/ftIN mm IN mm IN mm

C3240 2 18 Solid 0.014 0.36 0.015 0.38 0.172 4.37 19.0

C3242 4 18 Solid 0.014 0.36 0.015 0.38 0.195 4.95 19.0

C3241 2 16 Solid 0.016 0.41 0.015 0.38 0.196 4.98 20.0

C3243 4 16 Solid 0.016 0.41 0.015 0.38 0.231 5.87 20.0

C3244 2 14 Solid 0.018 0.46 0.020 0.51 0.242 6.15 20.0

C3245 4 14 Solid 0.018 0.46 0.020 0.51 0.286 7.26 20.0

C3246 2 12 Solid 0.020 0.51 0.020 0.51 0.282 7.16 22.0

C3247 4 12 Solid 0.020 0.51 0.020 0.51 0.333 8.45 22.0

*Capacitance between conductors

Page 139: Cross-Reference & Online Spec Sheets - Datasheet Archive

128

Electronics Fire Alarm/Life Safety Cable

Mid-Capacitance, Shielded, Plenum NEC Type FPLP for Microprocessor-Controlled Systems

Product Construction Conductor: •18thru12AWGfullyannealedsolidbare

copper per ASTM B-3

Insulation: •Premium-grade,coIor-coded

fluoropolymer •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester foil,

25%overlap,minimum •Strandedtinnedcopperdrainwire

Jacket: •Premium-grade,redFlexguard® PVC •Temperaturerange:0°Cto+75°C •Includesripcord

Applications: •Addressablefirealarmsystems •Firealarmsystems •Voicecommunications •Smokedetectors •Pullboxes •Suggestedvoltagerating:300volts

Compliances: •NECArticle760TypeFPLP

(UL:75°C,300V) •CaliforniaStateFireMarshallApproved •DesignedtomeetNFPA262andCSA

FT-6 Steiner Tunnel Fire Tests for Plenum Applications

Features: •RedPVCjacketforeasycriticalcircuit

identification

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM.INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOMINAL CAP. *pF/ft

INCHES mm INCHES mm INCHES mm A B

C3167 2 18 Solid 0.014 0.36 0.015 0.38 0.172 4.37 31.0 56.0

C3170 4 18 Solid 0.014 0.36 0.015 0.38 0.202 5.13 28.0 50.0

C3168 2 16 Solid 0.016 0.41 0.015 0.38 0.203 5.16 33.0 59.0

C3171 4 16 Solid 0.016 0.41 0.015 0.38 0.238 6.05 29.0 53.0

C3172 2 14 Solid 0.018 0.46 0.020 0.51 0.247 6.27 35.0 63.0

C3173 4 14 Solid 0.018 0.46 0.020 0.51 0.289 7.34 30.0 56.0

C3174 2 12 Solid 0.020 0.51 0.020 0.51 0.289 7.34 38.0 68.0

C3175 4 12 Solid 0.020 0.51 0.020 0.51 0.340 8.64 33.0 60.0

*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFCOND. COLOR

1 Black2 Red3 Brown4 Blue

Page 140: Cross-Reference & Online Spec Sheets - Datasheet Archive

129

Fire Alarm/Life Safety Cable Electronics

Product Construction Conductor: •22and18AWGfullyannealedsolidbare

copper per ASTM B-3

Insulation: •Premium-grade,color-codedPVC •Colorcode:Seepage229fortheCSA

Fire Alarm Color Code Chart

Jacket: •Premium-grade,redPVC;brownasan

option •Temperaturerange:-20°Cto+105°C •TRU-Mark® print legend contains

footage markings from 1000' to 0'

Applications: •Wiringoffirealarms •Smokealarms •Voicecommunications •Burglaralarms •Fireprotectioncircuits •Suggestedvoltagerating:300volts

Compliances: •NECArticle725PLTC(UL:105˚C,300V) •NECArticle760TypeFPL

(UL:105˚C,300V) •CSAFAS105(CSA:105˚C,300V) •C22.2No.208-03(R2008) •DesignedtomeetUL70,000BTU

Vertical Tray Flame Test •PassesCSAFT-4VerticalFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOGNUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS

NOM. JACKETTHICKNESS NOMINAL O.D.

INCHES mm INCHES mm INCHES mm

C4328A 3 22 Solid 0.012 0.30 0.042 1.07 0.279 7.09

C4329A 6 22 Solid 0.012 0.30 0.042 1.07 0.350 8.89

C4330A 12 22 Solid 0.012 0.30 0.053 1.35 0.474 12.04

C4331A 15 22 Solid 0.012 0.30 0.053 1.35 0.523 13.28

C4332A 27 22 Solid 0.012 0.30 0.063 1.60 0.672 17.07

C4333A 6 18 Solid 0.015 0.38 0.053 1.35 0.487 12.37

Multi-Paired, Unshielded, Non-Plenum CSA FAS 105, FPL (UL), NEC Type PLTC

Page 141: Cross-Reference & Online Spec Sheets - Datasheet Archive

130

Electronics

Sound, Alarm & Security Cable 7

Index Page

Composite Access Control Cable 131

Composite Access Control Cable, Plenum 132

Composite Access Control Cable, Riser 133

Multi-Conductor, Unshielded, Riser 134

Multi-Conductor, Shielded, Riser 135

Multi-Conductor, Unshielded, Plenum 136

Multi-Conductor, Shielded, Plenum 137

Telephone Station/Intercom & Speaker/Burglar Alarm 138

Antenna Rotor 139

Low-Voltage Sprinkler Wire 140

Thermostat Wire Type LVT 141

Thermostat Wire Type CL2 142

Thermostat Wire, Unjacketed 143

Carol® Helix/Hi-Temp® Category 6 Cable 144

Carol® Helix/Hi-Temp® Category 5e Cable 145

The sound and security industry in the United States has grown from a simple and unsophisticated business, begun some 45 years ago, to one which has developed technology to the degree that specialized wires and cables are now much in demand.

No longer are the security and sound industries characterized by large electromechanical relays and large contactors; today these circuits incorporate the latest in microprocessors and solid state devices to not only improve functionality but also to guarantee performance.

As a major wire producer, our role is to ensure that the wires and cables that go into these systems are as reliable as the other components … the net result is a fully integrated system which will provide peace of mind to the system user.

Also in this section are General Cable’s Carol® Brand wire and cable designs suitable for a variety of applications, both in industrial and commercial

environments, including telephone systems, intercoms, burglar alarms, business machines and thermostats.

Aside from the quality materials used in these designs, specifiers and users of Carol® Brand wire and cable products have come to expect that these cables are registered and certified with the leading regulatory agencies such as Underwriters Laboratories … and we haven’t let you down!

Carol® Brand designs have proven themselves in the area of sound and security over time; most are fabricated with solid or stranded, bare copper conductors with insulations and jackets of premium grades of PVC. We offer both parallel and cabled designs both with and without shields. Sequential footage markings on the jackets are offered on all products.

General Cable Carol® Brand products are conveniently packaged in 1000' or 500' Iengths to assist the installer.

Page 142: Cross-Reference & Online Spec Sheets - Datasheet Archive

131

General Cable’s Carol® Brand Composite Access Control Cable is manufactured for use in Building Access & Control. The cable is designed to allow for a single cable run that incorporates the four components required for card readers, door contacts, locking power and retinal scanners in commercial buildings, distribution centers, manufacturing facilities and government buildings.

The cables are installer friendly, as they save time and money on installation. With multiple cables under one jacket, time is saved in preparation and setup, pulling and termination. The convenience of these cables at installation makes them a popular choice for multiple Access Control applications.

When your job requires Access Control cable, think of Carol® Brand cables first. Remember, you can always Demand Better...Expect More™ with General Cable Carol® Brand Electronic Cables. We manufacture over 1,300 standard electronic cables that we can ship direct from stock, and we have the technical staff and design expertise to meet any custom cable requirement.

Special Application Cable

Hook-Up Wire

Plenum Cable

Coaxial Cable

Microphone Cable

Computer Cable

General Purpose Cable

Multi-Conductor Communication & Control Cable

Multi-Paired Communication & Control Cable

Fire Alarm Cable

Sound & Security Cable

Carol® Brand CompositeAccess Control Cable

For more information, contact your local General Cable representative.

E L E C T R O N I C S P R O D U C T B U L L E T I N

Page 143: Cross-Reference & Online Spec Sheets - Datasheet Archive

132

Electronics Sound, Alarm and Security Cable

Product Construction: Conductor: •Strandedbarecopper

Jacket: •Flexguard® PVC •Temperaturerange:0˚Cto+60˚C •Individualelementsmarkedfor

application (see diagram below) •Yellowoveralljacket

Shields: •Choicebetweenall4elementsshielded

or just the 3-pair element shielded

Applications: •Securitysystems •Accesscontrol •Cardreader •Doorcontrol •REX •Power-limitedcontrols

Compliances: •NECArticle800TypeCMP(UL),c(UL) •RoHSCompliantDirective2002/95/EC

Packaging: •500'and1000'reels

Composite Access Control Cable, Plenum NEC Type CMP, UL, c(UL)

Jacket Color Coding & Component Application

Jacket Color Component Cable Type ApplicationGray 1 4 Conductor, 18 AWG Lock Power

Orange 2 3 Pair, 22 AWG Card Reader

White 3 2 Conductor, 22 AWG Door Contact

Blue 4 4 Conductor, 22 AWG Rex/Spare

CATALOGNUMBER

OVERALLNOMINAL O.D.

INCH (MM)COMPONENT

NO.COMPONENT

DESCRIPTIONSCONDUCTORS COLOR CODE

COMPONENTNOMINAL O.D.

INCH (MM)

INSULATIONTHICKNESSINCH (MM)

4EPL4S 0.430

1 4 Cond, 18 AWG,Shielded

White, Black,Red, Green 0.180 (4.572) 0.008 (0.2032)

2 3 Pair, 22 AWG, Shielded

White & Green, Orange & Brown,

Red & Black0.195 (4.593) 0.008 (0.2032)

3 2 Cond, 22 AWG, Shielded Red, Black 0.125 (3.175) 0.008 (0.2032)

4 4 Cond, 22 AWG, Shielded

White, Black,Red, Green 0.145 (3.683) 0.008 (0.2032)

4EPL1S 0.420

1 4 Cond, 18 AWG,Unshielded

White, Black,Red, Green 0.180 (4.572) 0.008 (0.2032)

2 3 Pair, 22 AWG, Shielded

White & Green, Orange & Brown,

Red & Black0.195 (4.593) 0.008 (0.2032)

3 2 Cond, 22 AWG, Unshielded Red, Black 0.125 (3.175) 0.008 (0.2032)

4 4 Cond, 22 AWG, Unshielded

White, Black,Red, Green 0.145 (3.683) 0.008 (0.2032)

Door Contact

Rex/Spare

Card Reader

Lock Power

Page 144: Cross-Reference & Online Spec Sheets - Datasheet Archive

133

Sound, Alarm and Security Cable Electronics

Product Construction: Conductor: •Strandedbarecopper

Jacket: •PVC •Temperaturerange:-20˚Cto+60˚C •Individualelementsmarkedfor

application (see diagram below) •Blueoveralljacket

Shields: •Choicebetweenall4elementsshielded

or just the 3-pair shielded

Applications: •Securitysystems •Accesscontrol •Cardreader •Doorcontrol •REX •Power-limitedcontrols

Compliances: •NECArticle800TypeCMR(UL),c(UL) •RoHSCompliantDirective2002/95/EC

Packaging: •500'and1000'reels

Composite Access Control Cable, Riser NEC Type CMR, UL, c(UL)

CATALOGNUMBER

OVERALLNOMINAL O.D.

INCH (MM)COMPONENT

NO.COMPONENT

DESCRIPTIONSCONDUCTORS COLOR CODE

COMPONENTNOMINAL O.D.

INCH (MM)

INSULATIONTHICKNESSINCH (MM)

4ERS4S 0.430

1 4 Cond, 18 AWG,Shielded

White, Black,Red, Green 0.180 (4.572) 0.008 (0.2032)

2 3 Pair, 22 AWG, Shielded

White & Green, Orange & Brown,

Red & Black0.195 (4.593) 0.008 (0.2032)

3 2 Cond, 22 AWG, Shielded Red, Black 0.125 (3.175) 0.008 (0.2032)

4 4 Cond, 22 AWG, Shielded

White, Black,Red, Green 0.145 (3.683) 0.008 (0.2032)

4ERS1S 0.420

1 4 Cond, 18 AWG,Unshielded

White, Black,Red, Green 0.180 (4.572) 0.008 (0.2032)

2 3 Pair, 22 AWG, Shielded

White & Green, Orange & Brown,

Red & Black0.195 (4.593) 0.008 (0.2032)

3 2 Cond, 22 AWG, Unshielded Red, Black 0.125 (3.175) 0.008 (0.2032)

4 4 Cond, 22 AWG, Unshielded

White, Black,Red, Green 0.145 (3.683) 0.008 (0.2032)

Jacket Color Coding & Component Application

Jacket Color Component Cable Type ApplicationGray 1 4 Conductor, 18 AWG Lock Power

Orange 2 3 Pair, 22 AWG Card Reader

White 3 2 Conductor, 22 AWG Door Contact

Blue 4 4 Conductor, 22 AWG Rex/Spare

Door Contact

Rex/Spare

Card Reader

Lock Power

Page 145: Cross-Reference & Online Spec Sheets - Datasheet Archive

134

Electronics Sound, Alarm and Security Cable

Multi-Conductor, Unshielded, Riser NEC Type CMR and/or CL3R

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET WALL NOMINAL O.D.

INCHES mm INCHES mm INCHES mm

22 AWG CONDUCTORS

E1000S 2 22 Solid 0.007 0.20 0.015 0.38 0.118 3.00

E1001S 4 22 Solid 0.007 0.20 0.015 0.38 0.126 3.20

E1002S 2 22 7/30 0.008 0.20 0.015 0.38 0.122 3.10

E1003S 3 22 7/30 0.008 0.20 0.015 0.38 0.141 3.58

E1004S 4 22 7/30 0.008 0.20 0.015 0.38 0.141 3.66

E1006S 6 22 7/30 0.008 0.20 0.015 0.38 0.164 4.17

E1008S 8 22 7/30 0.008 0.20 0.015 0.38 0.180 4.57

E1010S 10 22 7/30 0.008 0.20 0.015 0.38 0.212 5.38

E1012S 12 22 7/30 0.008 0.20 0.015 0.38 0.219 5.56

20 AWG CONDUCTORS

E1022S 2 20 7/28 0.007 0.18 0.015 0.38 0.134 3.40

E1023S 3 20 7/28 0.008 0.20 0.015 0.38 0.134 3.40

E1024S 4 20 7/28 0.008 0.20 0.015 0.38 0.142 3.60

18 AWG CONDUCTORS

E1030S 2 18 Solid 0.008 0.20 0.015 0.38 0.144 3.66

E1032S 2 18 7/26 0.009 0.23 0.015 0.38 0.156 3.96

E1033S 3 18 7/26 0.009 0.23 0.015 0.38 0.166 4.22

E1034S 4 18 7/26 0.009 0.23 0.015 0.38 0.187 4.75

E1036S 6 18 7/26 0.008 0.20 0.015 0.38 0.225 5.72

E1038S 8 18 7/26 0.008 0.20 0.015 0.38 0.245 6.22

E1040S 10 18 7/26 0.008 0.20 0.015 0.38 0.282 7.16

E1041S 12 18 7/26 0.009 0.23 0.015 0.38 0.291 7.39

16 AWG CONDUCTORS

E1042S 2 16 19/.0117 0.009 0.25 0.015 0.38 0.178 4.52

E1043S 3 16 19/.0117 0.009 0.25 0.015 0.38 0.193 4.90

E1044S 4 16 19/.0117 0.009 0.25 0.015 0.38 0.210 5.33

14 AWG CONDUCTORS

E1052S* 2 14 19/.0147 0.013 0.33 0.015 0.38 0.224 5.69

E1054S* 4 14 19/.0147 0.013 0.33 0.015 0.38 0.264 6.71

12 AWG CONDUCTORS

E1062S* 2 12 19/.0185 0.013 0.33 0.015 0.38 0.260 6.60

E1064S* 4 12 19/.0185 0.013 0.33 0.015 0.38 0.312 7.92

* NEC CL3R only

Color Code ChartNO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 7 Orange

2 Red 8 Yellow

3 White 9 Violet

4 Green 10 Gray

5 Brown 11 Pink

6 Blue 12 Tan

Product Construction: Conductor: •Strandedorsolidbarecopperper

ASTM B-3, B-8 and B-286

Insulation: •Premium-grade,coIor-codedS-RPVC •Colorcode:Seechartbelow

Jacket: •Premium-grade,grayPVC •Sequentialfootagemarkingstofacilitate

installation •Temperaturerange:-20°Cto+75°C •Includesripcord

Applications: •Power-limitedcontrolcircuits •Wiringofthefollowingsystems:

Intercom Security Audio Background music

•Suggestedvoltagerating:300volts

Compliances: •NECArticle725TypeCL3R

(UL:75°C,150V) •NECArticle800TypeCMR

(UL:75°C,300V) •RoHSCompliantDirective2002/95/EC •CaliforniaStateFireMarshallApproved

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Page 146: Cross-Reference & Online Spec Sheets - Datasheet Archive

135

Sound, Alarm and Security Cable Electronics

Multi-Conductor, Shielded, Riser NEC Type CMR and/or CL3R

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET WALL NOMINAL O.D.

INCHES mm INCHES mm INCHES mm

22 AWG CONDUCTORS

E2000S 2 22 Solid 0.008 0.20 0.015 0.38 0.117 2.97

E2002S 2 22 7/30 0.008 0.20 0.015 0.38 0.132 3.35

E2003S 3 22 7/30 0.008 0.20 0.015 0.38 0.135 3.43

E2004S 4 22 7/30 0.008 0.20 0.015 0.38 0.147 3.73

E2006S 6 22 7/30 0.008 0.20 0.015 0.38 0.173 4.39

E2008S 8 22 7/30 0.008 0.20 0.015 0.38 0.195 4.95

E2010S 10 22 7/30 0.008 0.20 0.015 0.38 0.218 5.54

E2012S 12 22 7/30 0.010 0.25 0.015 0.38 0.238 6.05

20 AWG CONDUCTORS

E2022S 2 20 7/28 0.007 0.18 0.015 0.38 0.142 3.61

E2023S 3 20 7/28 0.008 0.20 0.015 0.38 0.151 3.84

E2024S 4 20 7/28 0.007 0.18 0.015 0.38 0.171 4.34

18 AWG CONDUCTORS

E2030S 2 18 Solid 0.009 0.20 0.015 0.38 0.147 3.73

E2032S 2 18 7/26 0.009 0.23 0.015 0.38 0.164 4.17

E2033S 3 18 7/26 0.009 0.23 0.015 0.38 0.172 4.37

E2034S 4 18 7/26 0.009 0.23 0.015 0.38 0.187 4.75

E2036S 6 18 7/26 0.008 0.20 0.015 0.38 0.230 5.54

E2038S 8 18 7/26 0.008 0.20 0.015 0.38 0.250 6.35

E2040S 10 18 7/26 0.008 0.20 0.015 0.38 0.287 7.29

E2041S 12 18 7/26 0.008 0.20 0.015 0.38 0.296 7.52

16 AWG CONDUCTORS

E2042S 2 16 19/.0117 0.009 0.23 0.015 0.38 0.189 4.80

E2043S 3 16 19/.0117 0.009 0.23 0.015 0.38 0.198 5.03

E2044S 4 16 19/.0117 0.009 0.23 0.015 0.38 0.219 5.56

14 AWG CONDUCTORS

E2052S* 2 14 19/.0147 0.013 0.33 0.015 0.38 0.245 6.22

E2054S* 4 14 19/.0147 0.013 0.33 0.015 0.38 0.269 6.83

12 AWG CONDUCTORS

E2062S* 2 12 19/.0185 0.013 0.33 0.015 0.38 0.281 7.14

E2064S* 4 12 19/.0185 0.013 0.33 0.015 0.38 0.312 7.92

* NEC CL3R only

Color Code ChartNO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 7 Orange

2 Red 8 Yellow

3 White 9 Violet

4 Green 10 Gray

5 Brown 11 Pink

6 Blue 12 Tan

Product Construction: Conductor: •Strandedorsolidbarecopperper

ASTM B-3, B-8 and B-286

Insulation: •Premium-grade,coIor-codedS-RPVC •Colorcode:Seechartbelow

Shield: •OverallFlexfoil® polyester supported

aluminum foil •Strandedtinnedcopperdrainwire

Jacket: •Premium-grade,grayPVC •Sequentialfootagemarkingstofacilitate

installation •Temperaturerange:-20°Cto+75°C •Includesripcord

Applications: •Power-limitedcontrolcircuits •Wiringofthefollowingsystems:

Intercom Security Audio Background music

•Suggestedvoltagerating:300volts

Compliances: •NECArticle725TypeCL3R

(UL:75°C,150V) •NECArticle800TypeCMR

(UL:75°C,300V) •RoHSCompliantDirective2002/95/EC •CaliforniaStateFireMarshallApproved

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Page 147: Cross-Reference & Online Spec Sheets - Datasheet Archive

136

Electronics Sound, Alarm and Security Cable

Color Code ChartNO. OFCOND. COLOR

NO. OFCOND. COLOR

1 Black 7 Orange

2 Red 8 Yellow

3 White 9 Violet

4 Green 10 Gray

5 Brown 11 Pink

6 Blue 12 Tan

Multi-Conductor, Unshielded, Plenum NEC Type CMP and/or CL3P

Product Construction: Conductor: •Strandedorsolidbarecopperper

ASTM B-3, B-8 and B-286

Insulation: •Premium-grade,coIor-codedFlexguard®

PVC •Colorcode:Seechartbelow

Jacket: •Premium-gradenaturalFlexguard® PVC •Sequentialfootagemarkingstofacilitate

installation •Temperaturerange:0°Cto+75°C •Ripcordavailable—consultCustomer

Service for details

Applications: •Power-limitedcontrolcircuits •Wiringofthefollowingsystems:

Intercom Security Audio Background music

•Suggestedvoltagerating:300volts

Compliances: •NECArticle725TypeCL3P

(UL:75°C,150V) •NECArticle800TypeCMP

(UL:75°C,300V) •DesignedtomeetNFPA262FlameTest •CaliforniaStateFireMarshallApproved

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET WALL NOMINAL O.D.

INCHES mm INCHES mm INCHES mm

22 AWG CONDUCTORS

E3000S 2 22 Solid 0.007 0.18 0.015 0.38 0.108 2.74

E3001S 4 22 Solid 0.007 0.18 0.015 0.38 0.124 3.15

E3002S 2 22 7/30 0.008 0.20 0.015 0.38 0.120 3.05

E3003S 3 22 7/30 0.008 0.20 0.015 0.38 0.127 3.23

E3004S 4 22 7/30 0.008 0.20 0.015 0.38 0.139 3.53

E3006S 6 22 7/30 0.008 0.20 0.015 0.38 0.164 4.17

E3008S 8 22 7/30 0.008 0.20 0.015 0.38 0.178 4.52

E3010S 10 22 7/30 0.008 0.20 0.015 0.38 0.194 4.92

E3012S 12 22 7/30 0.008 0.20 0.015 0.38 0.211 5.36

20 AWG CONDUCTORS

E3022S 2 20 7/28 0.009 0.23 0.015 0.38 0.138 3.51

E3023S 3 20 7/28 0.009 0.23 0.015 0.38 0.146 3.71

E3024S 4 20 7/28 0.009 0.23 0.015 0.38 0.161 4.09

18 AWG CONDUCTORS

E3030S 2 18 Solid 0.008 0.20 0.015 0.38 0.142 3.61

E3032S 2 18 7/26 0.008 0.20 0.015 0.38 0.156 3.96

E3033S 3 18 7/26 0.008 0.20 0.015 0.38 0.166 4.22

E3034S 4 18 7/26 0.008 0.20 0.015 0.38 0.187 4.75

E3036S 6 18 7/26 0.008 0.20 0.015 0.38 0.216 5.49

E3038S 8 18 7/26 0.008 0.20 0.015 0.38 0.235 5.97

16 AWG CONDUCTORS

E3042S 2 16 19/.0117 0.008 0.20 0.015 0.38 0.174 4.42

E3043S 3 16 19/.0117 0.008 0.20 0.015 0.38 0.185 4.70

E3044S 4 16 19/.0117 0.009 0.23 0.015 0.38 0.205 5.21

14 AWG CONDUCTORS

E3052S* 2 14 19/.0147 0.011 0.28 0.015 0.38 0.216 5.49

E3054S* 4 14 19/.0147 0.011 0.28 0.015 0.38 0.255 6.48

12 AWG CONDUCTORS

E3062S* 2 12 19/.0185 0.011 0.28 0.015 0.38 0.252 6.40

E3064S* 4 12 19/.0185 0.011 0.28 0.015 0.38 0.298 7.57

* NEC CL3P only

Page 148: Cross-Reference & Online Spec Sheets - Datasheet Archive

137

Sound, Alarm and Security Cable Electronics

Multi-Conductor, Shielded, Plenum NEC Type CMP and/or CL3P

Product Construction: Conductor: •Strandedorsolidbarecopperper

ASTM B-3, B-8 and B-286

Insulation: •Premium-grade,coIor-codedFlexguard®

PVC

Shield: •OverallFlexfoil® polyester supported

aluminum foil •Strandedtinnedcopperdrainwire

Jacket: •Premium-gradenaturalFlexguard® PVC •Sequentialfootagemarkingstofacilitate

installation •Temperaturerange:0°Cto+75°C •Ripcordavailable—consultCustomer

Service for details

Applications: •Power-limitedcontrolcircuits •Wiringofthefollowingsystems:

Intercom Security Audio Background music

•Suggestedvoltagerating:300volts

Compliances: •NECArticle725TypeCL3P

(UL:75°C,150V) •NECArticle800TypeCMP

(UL:75°C,300V) •DesignedtomeetNFPA262FlameTest •CaliforniaStateFireMarshallApproved

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET WALL NOMINAL O.D.

INCHES mm INCHES mm INCHES mm

22 AWG CONDUCTORS

E2100S 2 22 Solid 0.007 0.18 0.015 0.38 0.116 2.95

E2102S 2 22 7/30 0.008 0.20 0.015 0.38 0.128 3.25

E2103S 3 22 7/30 0.008 0.20 0.015 0.38 0.131 3.33

E2104S 4 22 7/30 0.008 0.20 0.015 0.38 0.147 3.73

E2106S 6 22 7/30 0.008 0.20 0.015 0.38 0.176 4.47

E2108S 8 22 7/30 0.010 0.25 0.015 0.38 0.184 4.67

20 AWG CONDUCTORS

E2122S 2 20 7/28 0.009 0.23 0.015 0.38 0.143 3.63

E2123S 3 20 7/28 0.009 0.23 0.015 0.38 0.151 3.84

E2124S 4 20 7/28 0.009 0.23 0.015 0.38 0.166 4.22

18 AWG CONDUCTORS

E2200S 2 18 Solid 0.008 0.20 0.015 0.38 0.148 3.76

E2202S 2 18 7/26 0.008 0.20 0.015 0.38 0.164 4.17

E2203S 3 18 7/26 0.008 0.20 0.015 0.38 0.169 4.29

E2204S 4 18 7/26 0.008 0.20 0.015 0.38 0.185 4.70

E2206S 6 18 7/26 0.010 0.25 0.015 0.38 0.230 5.84

E2208S 8 18 7/26 0.010 0.25 0.015 0.38 0.252 6.40

16 AWG CONDUCTORS

E2242S 2 16 19/.0117 0.008 0.20 0.015 0.38 0.179 4.55

E2243S 3 16 19/.0117 0.008 0.20 0.015 0.38 0.190 4.83

E2244S 4 16 19/.0117 0.008 0.20 0.015 0.38 0.209 5.31

14 AWG CONDUCTORS

E2252S* 2 14 19/.0147 0.008 0.20 0.015 0.38 0.207 5.26

E2254S* 4 14 19/.0147 0.008 0.20 0.015 0.38 0.260 6.60

12 AWG CONDUCTORS

E2262S* 2 12 19/.0185 0.008 0.20 0.015 0.38 0.244 6.20

E2264S* 4 12 19/.0185 0.008 0.20 0.015 0.38 0.288 7.32

* NEC CL3P only

Color Code ChartNO. OFCOND. COLOR

1 Black

2 Red

3 White

4 Green

5 Brown

6 Blue

7 Orange

8 Yellow

Page 149: Cross-Reference & Online Spec Sheets - Datasheet Archive

138

Electronics Sound, Alarm and Security Cable

Telephone Station/Intercom & Speaker/ Burglar Alarm NECTypesCMRorCM/CL2andCMX-Outdoor

Product Construction: Conductor: •22thru18AWGonetinned/onebarefully

annealed stranded copper •StrandedbarecopperperASTMB-3or

stranded tinned copper per ASTM B-33

Insulation: •Premium-grade,color-codedPVC •Temperaturerange:-20°Cto+60°C •Colorcode:Seechartbelow

Applications: •Burglaralarms •Intercomsystems •Remotecontrolcircuits •Suggestedvoltagerating:150volts

Features: •Polarityridgeforeasyidentification

Compliances: •NECArticle725TypeCL2(UL:60°C,150V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTUVertical

TrayFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Color Code Chart

NO. OFPAIRS COLOR

NO. OFPAIRS COLOR

1 Red 3 Yellow2 Green 4 Black

Color Code Chart (Bandmarked)NO. OFPAIRS COLOR

NO. OFPAIRS COLOR

1 White-Blue BandBlue 2 White-Orange Band

Orange

Color Code Chart

STOCK COLORSORDERING

SUFFIX STOCK COLORSORDERING

SUFFIX1. White-White 02 3. Black-White 962. Brown-Brown 08

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

INCHES mm INCHES mm INCHES mm

INTERCOM, SPEAKER AND BURGLAR ALARMC4408* 2 22 Solid 0.007 0.18 0.020 0.51 0.115 2.92C4408ST* 2 22 7/.0096 0.007 0.18 0.020 0.51 0.125 3.18C4410 3 22 Solid 0.007 0.18 0.016 0.41 0.118 3.00C4412* 4 22 Solid 0.007 0.18 0.015 0.38 0.125 3.18C4412ST* 4 22 7/.0096 0.007 0.18 0.015 0.38 0.135 3.43

TELEPHONE STATION CATEGORY 3

CATALOGNUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

INCHES mm INCHES mm INCHES mm

C4413 2 24 Solid 0.007 0.18 0.015 0.38 0.145 x0.095

3.68 x2.41

BURGLAR ALARM

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS NOMINAL O.D.

NOM.* C-C CAP. pF/ftINCHES mm INCHES mm

C6310 2 22 7/30 0.024 0.61 0.156 3.96 20.0C6311 2 20 7/28 0.024 0.61 0.172 4.37 22.5C6312 2 18 7/0.015 0.024 0.61 0.192 4.88 24.5C6313 3 18 7/0.015 0.024 0.61 0.202 5.13 28.5

*Capacitance between conductors

Note: Outdoor rating allows cable to be exposed for short distances from the network interface device on the outside of the house to the point where the cable enters the house. This type of cable is not to be buried or direct buried.

Product Construction: Conductor: •Solidorstrandedbarecopperper

ASTM B-3

Insulation: •Semi-rigid,flame-retardantPVC •Colorcode:Seechartbelow

Core: •Conductorsinaquadconfiguration(C4412)

Jacket: •Low-temperature,flame-retardantbeige

PVC(-20°Cto+60°C) •Sequentialfootagemarkingstofacilitate

installation •Cablesaresuitableforinstallationwith

T-18 staples

Applications: •Intercomsystemsandspeakerextension

service •Suggestedvoltagerating:300volts •C4413 only: Product is in conformance

with TIA 568C, TIA 570B standards and theFCCPart68rulingwhichrequirestelephone system cables for voice and data services into homes to be at minimum category 3, 2 pr. 22 AWG solid.

Compliances: •NECArticle800TypeCMR/CMX-Indoor/

Outdoor;ULListed(60°C,300V) •CoilPacks(500')–NECArticle800Type

CM/CMX-Indoor/Outdoor;ETLListed •CoilPacks(500')–NECArticle725Type

CL2; ETL Listed •C4413only,Category3 •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Burglar

Alarm Cable

also available

in 500' Coil

Packs*

Page 150: Cross-Reference & Online Spec Sheets - Datasheet Archive

139

Sound, Alarm and Security Cable Electronics

Antenna Rotor

Product Construction: Conductor: •22thru18AWGfullyannealedstranded

bare copper per ASTM B-3

Insulation: •Premium-grade,coIor-codedPVC •Colorcode:Seechartsbelow

Jacket: •Permaline® polyethylene, black •Temperaturerange:-20°Cto+60°C

Applications: •Rotorantennacontrols •Outdoorinstallations •Directburial •Suggestedvoltagerating:200volts

Features: •Permaline® jackets resist deterioration •Sunlight-resistant •Moisture-andsalt-resistant

Compliances: •RoHSCompliantDirective2002/95/EC

Product Construction: Conductor: •22thru16AWGfullyannealedstranded

bare copper per ASTM B-3

Insulation: •Premium-grade,color-codedPVC •Colorcode:Seechartbelow

Jacket: •PVC,chromegrayorblack

(C4080, C4090) •Temperaturerange:-20°Cto+80°C

Applications: •CompatiblewithAllianceHam/CBand

TV rotors •Suggestedvoltagerating:200volts

Compliances: •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

INCHES mm INCHES mm INCHES mm

C5076 4 22 7/30 0.010 0.25 0.022 0.56 0.165 4.19

C5086 5 22 7/30 0.010 0.25 0.022 0.56 0.175 4.45

C5096 8 22 7/30 0.010 0.25 0.020 0.51 0.205 5.21

C5078 4 20 10/30 0.009 0.23 0.023 0.58 0.180 4.57

C5460† 2 18 16/30 0.016 0.25 0.020 0.51 0.208 5.28

C5084 4 18 16/30 0.016 0.40 0.030 0.76 0.245 6.22

†Color Code Black/Red

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

INCHES mm INCHES mm INCHES mm

C1118 4 22 7/30 0.010 0.25 0.020 0.51 0.161 4.09

C1124 5 22 7/30 0.010 0.25 0.020 0.51 0.175 4.45

C1130 8 22 7/30 0.010 0.25 0.020 0.51 0.205 5.21

C1119 4 20 10/30 0.010 0.25 0.020 0.51 0.180 4.57

C1126 5 20 10/30 0.010 0.25 0.020 0.51 0.197 5.00

C1123 4 18 16/30 0.016 0.40 0.030 0.76 0.255 6.48

COMBINATION ROTOR CABLE

C4080 8 6-222-18

7/3016/30

0.0120.016

0.300.41 0.030 0.76 0.260 6.60

C4090 8 6-202-16

10/3026/30

0.0100.016

0.250.41 0.030 0.76 0.280 7.11

Antenna Rotor CableColor Code Chart

NO. OFCOND. COLOR

1 Black2 White3 Red4 Green5 Yellow6 Blue7 Brown8 Orange

Combination Rotor Cable Color Code Chart

NO. OFCOND. COLOR

16/18 ga.1 Black2 Red

20/22 ga.1 White2 Green3 Yellow4 Blue5 Brown6 Orange

Page 151: Cross-Reference & Online Spec Sheets - Datasheet Archive

140

Electronics Sound, Alarm and Security Cable

Low-Voltage Sprinkler Wire 60ºC 30 Volts UL

Product Construction: Conductor: •18AWGfullyannealedsolidbarecopper

per ASTM B-3

Insulation: •Premium-grade,color-codedPVC •Premium-gradePEjacket,black •Nylonripcordtofacilitatejacketremoval •Temperaturerange:-20ºCto+60ºC •Colorcode:Seechartatright

Jacket Marking: •CAROL(SIZE)30VSPRINKLER

SYSTEMSWIRE-DIRECTBURIALE54567 (UL)

Applications: •Low-voltagegolfcoursesatellite

sprinkler control •Residentialsprinklersolenoidcontrol

Compliances: •ULListedunderaULMiscellaneous

Wire file •ULListedforoutdoorsapplications •ULListedfordirectburialapplications

Packaging: •Seetabulardataabove •PleasecontactCustomerServicefor

packaging and color options

Color Code ChartNO. OF

CONDUCTORS COLOR

1 Black2 White3 Red4 Green5 Orange6 Yellow7 Blue8 Brown9 Gray

10 Purple

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

LENGTHOF CORD

(FEET)PACKAGE

TYPE

POWER RATING (1) PKGPERCTN.

APPROX.WEIGHT

PERCTN (LBS)

(S)

CARTONDIMENSIONS(H x W x D) UPC NUMBERVOLTS AMPS WATTS

LOW VOLTAGE SPRINKLER WIRE - 30 VOLTS - UL

23824-60-01 4 18 100 Cuff 30 15 450 6 22 8.5 x 12.25 x 14 079407238248

23804-18-01 4 18 500 Spool 30 15 450 1 18 10.625 x 10.625 x 6.313 079407908047

23815-60-01 5 18 50 Cuff 30 15 450 6 13 8.5 x 12.25 x 14 079407238156

23825-60-01 5 18 100 Cuff 30 15 450 6 27 9.5 x 14 x 17 079407238255

23805-18-01 5 18 500 Spool 30 15 450 1 22 10.625 x 10.625 x 6.313 079407908054

23817-60-01 7 18 50 Cuff 30 15 450 6 18 8.5 x 12.25 x 14 079407238170

23827-60-01 7 18 100 Cuff 30 15 450 6 36 9.5 x 14 x 17 079407238279

23807-18-01 7 18 500 Spool 30 15 450 1 31 10.625 x 10.625 x 6.313 079407908078

23810-18-01 10 18 500 Reel 30 15 450 1 44 — 079407908108

(1)AmpsandwattsareofferedONLYasaguidetotheenduser.(s) Actual shipping weight may vary.

Page 152: Cross-Reference & Online Spec Sheets - Datasheet Archive

141

Sound, Alarm and Security Cable Electronics

Thermostat Wire 60ºC 30 Volt CSA Type LVT

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS NOMINAL O.D.

APPROX.NET WEIGHT

LBS/m (S)STD.CTN.INCHES mm INCHES mm

18 AWG THERMOSTAT WIRE – 30 VOLT – CSA TYPE LVT

05092 2 18 Solid 0.017 0.43 0.210 5.33 25 2000'

05093* 3 18 Solid 0.017 0.43 0.222 5.64 33 500'

05094 4 18 Solid 0.017 0.43 0.242 6.15 41 1000'

05095 5 18 Solid 0.017 0.43 0.262 6.65 50 1000'

05096* 6 18 Solid 0.017 0.43 0.280 7.11 60 1000'

05097* 7 18 Solid 0.017 0.43 0.285 7.24 65 1000'

05098* 8 18 Solid 0.017 0.43 0.304 7.75 74 1000'

05099* 9 18 Solid 0.017 0.43 0.328 8.33 83 1000'

05091* 10 18 Solid 0.017 0.43 0.360 9.14 92 250'

*Non-stock item; minimum quantity purchase required.(S) Actual shippng weight may vary.

6.0

5.5

5.0

4.5

4.0

3.5

3.0

2.5

2.0

1.5

1.0

.5

00 50 100 150 200 250 300 350 400 450 500

NE

C R

EC

OM

ME

ND

ED

MA

X V

OLT

DR

OP

3% M

AX

VOLTAGE DROP PER (1) AMPBASED ON 115 VOLTS

VO

LTA

GE

DR

OP

/AM

P

LENGTH OF RUN (FEET)

APPROXIMATE VOLTAGE DROP/AMP AT 68ºF

26 A

WG

24 A

WG

23 A

WG

22 A

WG

21 A

WG

20 A

WG

18 AWG

16 AWG

Color Code ChartNO. OF

CONDUCTORS COLORS

2 White, Red3 White, Red, Green4 White, Red, Green, Blue5 White,Red,Green,Blue,Yellow6 White,Red,Green,Blue,Yellow,Brown7 White,Red,Green,Blue,Yellow,Brown,Orange8 White,Red,Green,Blue,Yellow,Brown,Orange,Black9 White,Red,Green,Blue,Yellow,Brown,Orange,Black,Purple

10 White,Red,Green,Blue,Yellow,Brown,Orange,Black,Purple,Gray

Product Construction: Conductors: •8AWGannealedsolidbarecopperper

ASTM B-3

Insulation: •Premium-grade,color-codedPVC •Colorcode:Seechartbelow

Jacket: •Polyvinylchloride(PVC),brown •Temperaturerange:-20ºCto+60ºC

Jacket Marking: •CAROL(SIZE)CSALL#TYPELVTFT-4

Applications: •Thermostatcontrol •Heatingandairconditioninginstallations •Touch-platesystems •Burglaralarms •Intercomsystems •Doorbells •Annunciatorandbellsystems •Remotecontrolunits •Signalsystems •Otherlow-voltageinstallations

Compliances: •CSATypeLVT •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Page 153: Cross-Reference & Online Spec Sheets - Datasheet Archive

142

Electronics Sound, Alarm and Security Cable

Thermostat Wire 105ºC 150 Volt UL Type CL2

Product Construction: Conductors: •20and18AWGannealedsolidbare

copper per ASTM B-3

Insulation: •Premium-grade,coIor-codedPVC •Colorcode:Seechartbelow

Jacket: •Polyvinylchloride(PVC),white •Temperaturerange:-20ºCto+105ºC

Jacket Marking: •CAROLAWGTYPECL2E#(UL)

105ºCSUNLIGHTRESISTANT-MADEIN USA

Applications: •Thermostatcontrol •Heatingandairconditioning

installations •Touch-platesystems •Burglaralarms •Intercomsystems •Doorbells •Annunciatorandbellsystems •Remotecontrolunits •Signalsystems •Otherlow-voltageinstallations

Industry Approvals: •ULListedTypeCL2

Compliances: •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS NOMINAL O.D.

APPROX.NET WEIGHT

LBS/m(S)STD.CTN.INCHES mm INCHES mm

20 AWG THERMOSTAT WIRE – 150 VOLT – UL TYPE CL2

05482 2 20 Solid 0.008 0.203 0.128 3.25 11 1000'

05483 3 20 Solid 0.008 0.203 0.135 3.43 16 1000'

05484 4 20 Solid 0.008 0.203 0.144 3.66 19 500'

05485 5 20 Solid 0.008 0.203 0.158 4.01 24 500'

05486 6 20 Solid 0.008 0.203 0.177 4.46 27 500'

05487 7 20 Solid 0.008 0.203 0.175 4.45 31 500'

05488 8 20 Solid 0.008 0.203 0.186 4.72 35 500'

05489 9 20 Solid 0.008 0.203 0.210 5.33 40 500'

05481 10 20 Solid 0.008 0.203 0.235 5.97 45 250'

18 AWG THERMOSTAT WIRE – 150 VOLT – UL TYPE CL2

05582 2 18 Solid 0.009 0.203 0.155 3.94 16 1000'

05583 3 18 Solid 0.009 0.203 0.164 4.17 22 1000'

05584 4 18 Solid 0.009 0.203 0.180 4.57 28 500'

05585 5 18 Solid 0.009 0.203 0.200 5.08 36 500'

05586 6 18 Solid 0.009 0.203 0.215 5.46 42 500'

05587 7 18 Solid 0.009 0.203 0.215 5.46 48 500'

05588 8 18 Solid 0.009 0.203 0.235 5.97 54 500'

05589 9 18 Solid 0.008 0.203 0.245 6.22 61 500'

05581 10 18 Solid 0.008 0.203 0.300 7.62 69 250'(S) Actual shipping weight may vary.

6.0

5.5

5.0

4.5

4.0

3.5

3.0

2.5

2.0

1.5

1.0

.5

00 50 100 150 200 250 300 350 400 450 500

NE

C R

EC

OM

ME

ND

ED

MA

X V

OLT

DR

OP

3% M

AX

VOLTAGE DROP PER (1) AMPBASED ON 115 VOLTS

VO

LTA

GE

DR

OP

/AM

P

LENGTH OF RUN (FEET)

APPROXIMATE VOLTAGE DROP/AMP AT 68ºF

26 A

WG

24 A

WG

23 A

WG

22 A

WG

21 A

WG

20 A

WG

18 AWG

16 AWG

Color Code ChartNO. OF

CONDUCTORS COLOR

2 White, Red

3 White, Red, Green

4 White, Red, Green, Blue

5 White,Red,Green,Blue,Yellow

6 White,Red,Green,Blue,Yellow,Brown

7 White,Red,Green,Blue,Yellow,Brown,Orange

8 White,Red,Green,Blue,Yellow,Brown,Orange,Black

9 White,Red,Green,Blue,Yellow,Brown,Orange,Black,Purple

10 White,Red,Green,Blue,Yellow,Brown,Orange,Black,Purple,Gray

Page 154: Cross-Reference & Online Spec Sheets - Datasheet Archive

143

Sound, Alarm and Security Cable Electronics

Thermostat Wire, Unjacketed 60ºC Low Voltage and Intercom Cable

Product Construction: Conductors: •20AWGannealedsolidbarecopperper

ASTM B-3

Insulation: •Premium-grade,coIor-codedPVC •Temperaturerange:-20ºCto+60ºC •Colorcode:Seechartbelow

Jacket: •Thisproductisunjacketed

Applications: •Thermostatcontrol •Heatingandairconditioninginstallations •Touch-platesystems •Burglaralarms •Intercomsystems •Doorbells •Annunciatorandbellsystems •Remotecontrolunits •Signalsystems •Otherlow-voltageinstallations

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Color Code ChartNO. OF

CONDUCTORS COLOR

2 White, Red

3 White, Red, Green

4 White, Red, Green, Blue

5 White,Red,Green,Blue,Yellow

6 White,Red,Green,Blue,Yellow,Brown

8 White,Red,Green,Blue,Yellow,Brown,Orange,Black

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS NOMINAL O.D.

APPROX.NET WEIGHT

LBS/m(S)STD.CTN.INCHES mm INCHES mm

20 AWG – TWISTED CONDUCTORS – NO JACKET

05782 2 20 Solid 0.008 0.203 0.098 2.49 7.5 4000'

05783 3 20 Solid 0.008 0.203 0.106 2.69 11.0 2000'

05784* 4 20 Solid 0.008 0.203 0.119 3.01 15.0 2000'

05785* 5 20 Solid 0.008 0.203 0.133 3.38 18.5 1000'

05786* 6 20 Solid 0.008 0.203 0.147 3.73 22.0 1000'

05788* 8 20 Solid 0.008 0.203 0.162 4.11 30.0 1000'

*Non-stock item; minimum quantity purchase required.(S) Actual shippng weight may vary.

Page 155: Cross-Reference & Online Spec Sheets - Datasheet Archive

144

Electronics Sound, Alarm and Security Cable

Carol® Helix/Hi-Temp® Category 6 Cable Standard-Compliant Solution

Product Construction: Conductors: •23 AWG solid bare annealed copper

Separator •Tape

Insulation •Non-Plenum:Polyolefin •Plenum:Fluoropolymer

Rip Cord •Applied longitudinally under jacket

Jacket •Non-Plenum:flame-retardantPVC •Plenum:low-smoke,flame-retardant

PVC •TRU-Mark® print legend contains

footage markings from 1000' to 0'

Applications: •IEEE802.3:1000BASE-T(Gigabit

Ethernet),100BASE-TX,10BASE-T •ANSI/TIA/EIA854:1000BASE-TX •155 Mp/s, 1.2 Gb/s ATM •ANSIX3.263:100Mb/s •IEEE802.3afDTEPower(PoE) •Digitalvideo

Compliances: •ANSI/TIA/EIA568B.2-1(Category6) •ANSI/TIA/EIA862(Building

Automation) •ISO/IEC11801Ed.2.0(ClassE) •ICEAS-102-700(Category6) •UL&c(UL)TypeCMP(NFPA262and

CSAFT-6SteinerTunnelFireTestsforPlenum Applications)

•UL444 •RoHSCompliantDirective2002/95/EC •Third-partyverifiedforguaranteed

performance

Packaging: •1000' Pull-Pac® Il •1000' Spool-Pac®

PART NUMBERSPULL-PAC® II SPOOL-PAC®

JACKET COLORCMR

(NON-PLENUM)CMP

(PLENUM)CMR

(NON-PLENUM)CMP

(PLENUM)

Blue CR6.30.07 CP6.30.07 CR6.A3.07 CP6.A3.07White CR6.30.02 CP6.30.02 CR6.A3.02 CP6.A3.02Gray CR6.30.10 CP6.30.10 CR6.A3.10 CP6.A3.10Green CR6.30.06 CP6.30.06 CR6.A3.06 CP6.A3.06Yellow CR6.30.05 CP6.30.05 CR6.A3.05 CP6.A3.05Red CR6.30.03 CP6.30.03 CR6.A3.03 CP6.A3.03

ELECTRICAL PERFORMANCE

FREQUENCYMHZ

PSACR(MIN)

ACR(MIN)

ATTENUATION(MAX)

PSNEXT(MIN)

NEXT(MIN)

PSELFEXT(MIN)

ELFEXT(MIN)

RETURN LOSS(MIN)

LCL(MIN)

ELTCTL(MIN)

1 70.3 72.3 2.0 72.3 74.3 64.8 67.8 20.0 40.0 35.04 59.3 61.5 3.8 63.3 65.3 52.8 55.7 23.0 40.0 23.010 51.3 53.3 6.0 57.3 59.3 44.8 47.8 25.0 40.0 15.016 46.7 48.7 7.6 54.2 56.2 40.7 43.7 25.0 38.0 10.920 44.3 46.3 8.5 52.8 54.8 38.8 41.7 25.0 37.0 9.0

31.25 39.2 41.2 10.7 49.9 51.9 34.9 37.9 23.6 35.1 5.162.5 29.9 32.0 15.4 45.4 47.4 28.9 31.8 21.5 32.0 5.0100 22.5 24.5 19.8 42.3 44.3 24.8 27.8 20.1 30.0 5.0150 14.9 16.9 24.7 39.7 41.7 21.3 24.3 18.9 28.2 5.0200 8.8 10.8 29.0 37.8 39.8 18.8 21.8 18.0 27.0 5.0250 3.5 5.5 32.8 36.3 38.3 16.8 19.8 17.3 26.0 5.0350 — — 39.8 34.1 36.1 13.9 16.9 16.3 — —400 — — 43.0 33.3 35.3 12.8 15.8 15.9 — —500 — — 48.9 31.8 33.8 10.8 13.8 15.2 — —

Notes:ValuesareexpressedindBper100m(328ft.)length.Valuesabove250MHzareforinformationalpurposesonly.

PHYSICAL DATACMR (NON-PLENUM) CMP (PLENUM)

NominalCableDiameter(in) 0.205 0.200Nominal Cable Weight (lbs/1000ft) 28 28Minimum Bend Radius (in) 1.0 1.0MaximumPullingForce(lbs) 32 32TemperatureRating(˚C) Installation: 0to+60 0to+60 Operation: -20to+75 -20to+75

ELECTRICAL CHARACTERISTICSDC Resistance(max)Ohms/100m(328ft)@20˚C 9.38DC Resistance Unbalance (max) Individual Pair % 4.0Delay Skew (max) ns/100m 45Nom. Velocity of Propagation % Speed of Light

CMP:70 CMR:68

Characteristic Impedance Frequency(f): 1-250MHz

Ohms 100 ± 15

Input Impedance Frequency(f): 1-100MHz 100-250 MHz

Ohms 100 ± 15 100 ± 22

Datasubjecttochangewithoutnotice.

CATEGORY 6 CROSS-SECTION

JACKET

TAPE

INSULATION

CONDUCTOR

RIP CORD

Page 156: Cross-Reference & Online Spec Sheets - Datasheet Archive

145

Sound, Alarm and Security Cable Electronics

Carol® Helix/Hi-Temp® Category 5e Cable Enhanced Transmission Throughput

Product Construction: Conductors: •24 AWG solid bare annealed copper

Insulation •Non-Plenum:Polyolefin •Plenum:Fluoropolymer

Rip Cord •Applied longitudinally under jacket

Jacket •Non-Plenum:flame-retardantPVC •Plenum:low-smoke,flame-retardant

PVC •TRU-Mark® print legend contains

footage markings from 1000' to 0'

Applications: •IEEE802.3:1000BASE-T(Gigabit

Ethernet),100BASE-TX,10BASE-T •52/155 Mp/s ATM •ANSIX3.263:100Mb/s •4/16 Mp/s token ring

Compliances: •ANSI/TIA/EIA568B.2(Category5e) •ICEAS-90-661(Category5e) •UL&c(UL)TypeCMR(UL1666)for

Non-Plenum •UL&c(UL)TypeCMP(NFPA262and

CSAFT-6SteinerTunnelFireTestsforPlenum Applications)

•UL444 •RoHSCompliantDirective2002/95/EC •Third-partyverifiedforguaranteed

performance

Packaging: •1000' Pull-Pac® Il •1000' Spool-Pac®

PART NUMBERSPULL-PAC® II SPOOL-PAC®

JACKET COLORCMR

(NON-PLENUM)CMP

(PLENUM)CMR

(NON-PLENUM)CMP

(PLENUM)

Blue CR5.30.07 CP5.30.07 CR5.A3.07 CP5.A3.07White CR5.30.02 CP5.30.02 CR5.A3.02 CP5.A3.02Gray CR5.30.10 CP5.30.10 CR5.A3.10 CP5.A3.10Green CR5.30.06 CP5.30.06 CR5.A3.06 CP5.A3.06Yellow CR5.30.05 CP5.30.05 CR5.A3.05 CP5.A3.05Red CR5.30.03 CP5.30.03 CR5.A3.03 CP5.A3.03

ELECTRICAL PERFORMANCE

FREQUENCYMHZ

PSACR(MIN)

ACR(MIN)

ATTENUATION(MAX)

PSNEXT(MIN)

NEXT(MIN)

PSELFEXT(MIN)

ELFEXT(MIN)

RETURN LOSS(MIN)

1 60.3 63.3 2.0 62.3 65.3 60.8 63.8 20.04 49.2 52.2 4.1 53.3 56.3 48.7 51.7 23.010 40.8 43.8 6.5 47.3 50.3 40.8 43.8 25.016 36.0 39.0 8.2 44.2 47.2 36.7 39.7 25.020 33.5 36.5 9.3 42.8 45.8 34.7 37.7 25.025 30.9 33.9 10.4 41.3 44.3 32.8 35.8 24.3

31.25 28.2 31.2 11.7 39.9 42.9 30.9 33.9 23.662.5 18.4 21.4 17.0 35.4 38.4 24.8 27.8 21.5100 10.3 13.3 22.0 32.3 35.3 20.8 23.8 20.1155 1.4 4.4 28.1 29.4 32.4 16.9 19.9 —200 — — 32.4 27.8 30.8 14.7 17.7 —250 — — 36.9 26.3 29.3 12.8 15.8 —350 — — 44.9 24.1 27.1 9.9 12.9 —

Notes:ValuesareexpressedindBper100m(328ft.)length.Valuesabove250MHzareforinformationalpurposesonly.

PHYSICAL DATACMR (NON-PLENUM) CMP (PLENUM)

NominalCableDiameter(in) 0.200 0.180

Nominal Cable Weight (lbs/1000ft) 21 19

Minimum Bend Radius (in) 1.0 1.0

MaximumPullingForce(lbs) 25 25

TemperatureRating(˚C)

Installation: 0to+60 0to+60

Operation: -10to+60 -10to+60ELECTRICAL CHARACTERISTICS

DC Resistance(max)Ohms/100m(328ft)@20˚C 8.9

DC Resistance Unbalance (max) Individual Pair % 3.0

Mutual Capacitance(nom)pF/ft@1KHz 14

Delay Skew (max) ns/100m 45

Nom. Velocity of Propagation % Speed of Light

CMP:72 CMR:70

Characteristic Impedance Frequency(f): 1-100MHz

Ohms 100 ± 15

Datasubjecttochangewithoutnotice.

CATEGORY 5e CROSS-SECTION

JACKET

INSULATION

CONDUCTOR

RIP CORD

Page 157: Cross-Reference & Online Spec Sheets - Datasheet Archive

146

Electronics

General Cable offers a variety of Carol® Brand wire and cable for audio/video and direct burial applications. From field production cable to microphone, snake, guitar and speaker cable, General Cable supports the increasingly demanding entertainment industry.

For extreme hard service, General Cable’s rubber microphone cables offer the ultimate in performance and service life. The rubber designs are highly flexible and designed to lie flat on studio floors, as well as provide high impact and abrasion resistance.

For outdoor and cold weather applications, microphone cable jacketed with Carolprene® provides the ultimate protection against ozone, oil and ultraviolet radiation.

These technically sophisticated cables are required to contain sources of interference and to protect against difficulties where they are unavoidable. In addition to providing the needed electrical characteristics, the cables are properly designed to handle demanding conditions, such as microphone hum, handling noise, crosstalk, electrostatic hum, SCR noise and common ground noise—either on stage, in a studio or at a remote venue.

For more information on these cables or for other special applications, please contact your General Cable sales representative.

Index Page

Command® Series Home Entertainment Cables Guide 147-148

Command® Series Cruise Ship Cables Guide 149-150

Command® Series Speaker Cable 151-155

Speaker Wire 156

Superflex® Speaker Wire 157

Pro Audio Speaker Wire 158

Special Audio, Communication & Instrumentation 159-161

Low Skew 4-Pair UTP 162

SmartWrap™ Bundled Cable 163

Direct Burial, Audio & Communication 164-165

Digital Audio Snake Cable 166

Analog Audio Snake Cable 167-168

Guitar/Instrument Cable 169

Ultra Flexible, Low Impedance 2-Conductor Microphone Cable 170

Multi-Conductor, Flexfoil® Shield 171

Multi-Conductor, Rubber, Braid Shield Microphone Cable 172

Multi-Conductor, Spiral Shield 173

Multi-Conductor, Braid Shield 174

Microphone Cable, Multi-Conductor, Carolprene®, Braid Shield 175

SMPTE-311 Hybrid Fiber Optic/Copper Camera Cable 176

Electronic News Gathering/Field Production Camera Cable 177

Audio/Video & Home Entertainment Cable 8

Page 158: Cross-Reference & Online Spec Sheets - Datasheet Archive

147

ELECTRONICS PRODUCT BULLETIN

Carol® Brand Command® Series Speaker Cables offer outstanding performance at an affordable price. The cables are highly flexible and available in a wide variety of options for in-wall use for home theaters as well as high definition applications. Whether your choice of speaker cable is constructed with Oxygen-Free Copper (OFC) or the more universally accepted Tough Pitch Copper (ETP), your speaker system will perform as designed and to your expectations. • OFCcopperisdefinedas99.95%pure.Therefiningprocess provides reduced oxygen content and other impurities.• HighConductiveElectrolyticToughPitchCopperisthemost widelyusedrefinedcopperwithintheelectroniccableindustry. Itisdefinedas99.9%-99.94%oxygen-freeandprovidesthe same level of conductivity as OFC.

There are a number of considerations to be made when choosing the proper speaker cable:

• ChoosetheproperAWGsizeforyoursystemdesign(Speaker Impedance,4or8ohm)andacceptablelossfortherequired cable distance.• Chooseanacceptablestrandingthatwillprovidebotheaseof installation and flexibility.• Chooseacablethatisappropriatetotheinstallationrelativeto any building standards or codes. 1.UL/CSA 2. NEC Riser, Plenum• Selectindividualjacketcolorsasnecessarytocontributeto roomorcircuitidentification.• Mostimportantly,choosethecablethatyoufeelcomfortable with.IfyouareconvincedthatOFCprovidesabenefitthatyou can hear, select our OFC product. If you choose our speaker cablesthatutilizeourhigh-conductiveETP,youwillhave selectedacablewiththesameresistanceforequalcablerun distances. The cable resistance is the primary selection criteria.

Applications:Digital audio with high strand, rope lay construction for superior flexibility

Applications:In-wall speakers and home theater systems

Applications:

Highdefinition,flexiblein-wall speakers and home theater systems

Features:Oxygen-Free Cu ConductorsSemi-extrudedjacketprovides a uniform round cable construction

Command® Series PREMIUM-Grade Speaker Cable NEC Type CL2

Command® Series Home Entertainment Speaker Cable NEC Type CL3, CM, AWM 1/11 A/B

Command® Series “HIGH DEF” Home Entertainment Speaker Cable NEC Type CL3, CM, AWM 1/11 A/B

Catalog No. Conductors AWG (Stranding) Length

C1458.55.90 2 16 (105 x 36) 25' Coil

C1458.56.90 2 16 (105 x 36) 50' Coil

C1458.57.90 2 16 (105 x 36) 100' Coil

C1458.15.90 2 16 (105 x 36) 250' Spool

C1461.55.90 2 14 (105 x 34) 25' Coil

C1461.56.90 2 14 (105 x 34) 50' Coil

C1461.57.90 2 14 (105 x 34) 100' Coil

C1461.15.90 2 14 (105 x 34) 250' Spool

C1463.55.90 2 12 (259 x 36) 25' Coil

C1463.56.90 2 12 (259 x 36) 50' Coil

C1463.15.90 2 12 (259 x 36) 250' Spool

Catalog No. Conductors AWG (Stranding) Length

C1700 2 12 (65 x 30) 500' Boxes

C1701 4 12 (65 x 30) 500' Boxes

C1702 2 14 (41 x 30) 500' Boxes

C1703 4 14 (41 x 30) 500' Boxes

C1704 2 16 (26 x 30) 500' Boxes

C1705 4 16 (26 x 30) 500' Boxes

Catalog No. Conductors AWG (Stranding) Length

C1800 2 12 (105 x 32) 500' Reels

C1801 4 12 (105 x 32) 500' Reels

C1802 2 14 (105 x 34) 500' Boxes

C1803 4 14 (105 x 34) 500' Reels

C1804 2 16 (65 x 34) 500' Boxes

C1805 4 16 (65 x 34) 500' Boxes

Command® SeriesHome Entertainment Cables

Page 159: Cross-Reference & Online Spec Sheets - Datasheet Archive

148

Command® Series Home Entertainment Cables

Applications:Digital audio, stereo systems

Command® Series Speaker Wire UL Listed (Wires, Misc)

Catalog No. Conductors AWG (Stranding) Length

C1356 2 24 (7 x 32) 500' Reels

C1362 2 22 (7 x 30) 500' Reels

C1360 2 20 (10 x 30) 500' Reels

C1357 2 18 (16 x 30) 500' Reels

C1358 2 16 (26 x 30) 500' Reels

C1361 2 14 (41 x 30) 500' Reels

C1363 2 12 (65 x 30) 500' Reels

Applications:Hometheaters,home audio systems

Command® Series Twisted Pair Speaker Cable NEC Type CMR

Catalog No. Conductors AWG (Stranding) Length

C1000A 2 22 (7 x 30) 500' Reels

C1001A 2 20 (7 x 28) 500' Reels

C1002A 2 18 (7 x 26) 500' Reels

C1003A 2 16 (19 x 29) 500' Reels

C1004A 2 14 (42 x 30) 500' Reels

C1005A 2 12 (65 x 30) 500' Reels

Applications:

Movietheaters,commercial sound installations

Commercial-Grade Speaker Cables NEC Type CMR

Catalog No. Conductors AWG (Stranding) Length

E1042S 2 16 (19/.0117) 500' Reels

E1044S 4 16 (19/.0117) 500' Reels

E1052S 2 14 (19/.0147) 500' Reels

E1054S 4 14 (19/.0147) 500' Reels

E1062S 2 12 (19/.0185) 500' Reels

E1064S 4 12 (19/.0185) 500' Reels

Applications:

Low- and high-impedence microphones, broadcast and studio use, communication and audio systems, shielded power supplies, control circuits, video and audio interconnecting cables, suggested voltage rating of 300

Rubber Jacketed Microphone Cable—High- and Low-Impedance

Catalog No. Conductors AWG

C1300 1 #20 (26 x 34)

C1301 2 #18 (41 x 34)

C1302 2 #20 (26 x 34)

Page 160: Cross-Reference & Online Spec Sheets - Datasheet Archive

149

Command® Series Cruise Ship Cables

ELECTRONICS PRODUCT BULLET IN

General Cable’s Carol® Brand Command Series Cruise Ship Cables are manufactured for use on cruise ships and yachts. These cables, which contain low smoke, zero halogen jackets, are designed to deliver premier audio, video and data communications capabilities aboard marine vessels.

The Carol Brand Command Series Cruise Ship Cables are RoHS compliant and approved by the American Bureau of Shipping (ABS) for use in marine applications. ABS is the leading international organization committed to promoting the security of life, property and the natural environment primarily through the development and verification of standards for the design, construction and operational maintenance of marine-related facilities. Their stamp on Carol Brand Command Series Cruise Ship Cables means that our cables have been certified for product compliance and will perform reliably in marine and off-shore environments. For more information on ABS, please visit: www.eagle.org

When your cruise ship or yacht project requires high-quality performance, think of Carol Brand Command Series Cruise Ship Cables. You can always Demand Better…Expect More™ with General Cable Carol Brand Electronic cables. We manufacture over 1,300 standard electronic cables that we can ship direct from stock, and we have the technical staff and design expertise to meet any customer cable requirement.

Special Application Cable

Hook-Up Wire

Plenum Cable

Coaxial Cable

Microphone Cable

Computer Cable

General Purpose Cable

Multi-Conductor Communication & Control Cable

Multi-Paired Communication & Control Cable

Fire Alarm Cable

Sound & Security Cable

Page 161: Cross-Reference & Online Spec Sheets - Datasheet Archive

150

Command® Series Cruise Ship Cables ABS Listed

Carol® Brand Command® Series Audio Control & Instrumentation Cable–Multi-Pair, Foil Shield

PART NUMBER

NO. OF PAIRS

AWG SIZE COND. STRAND. JACKET TYPE

JACKET COLOR/ TEMPERATURE

NOMINAL O.D.

INSULATION TYPE

INSULATION THICKNESS

CONDUCTOR COLOR CODE

NOM. CAP.* pF/FT

INCHES mm INCHES mm A B

C2520ACS 1 Pair 22 7/30 Tinned Copper

Flame Retardant Low Smoke

Halogen Free Polyolefin PVC

Black/-30°C +75°C

0.162 4.11 -40°C to +105°C Polypropylene

0.008 0.20 Black - Red 35 67

C1352ACS 2 Pair 22 7/30 Tinned Copper

Flame Retardant Low Smoke

Halogen Free Polyolefin PVC

Black/-30°C +75°C

0.196 4.98 -40°C to +105°C Polypropylene

0.008 0.20 P1: Black - Red, P2: Green - White

35 62

C6040ACS 3 Pair 22 7/30 Tinned Copper

Flame Retardant Low Smoke

Halogen Free Polyolefin PVC

Black/-30°C +75°C

0.270 6.86 -40°C to +105°C Polypropylene

0.010 0.25 P1: Black - Red, P2: Black - White, P3:

Black - Green

30 55

APPROVALS - (UL) c(UL) Listed Communication Cable Type CMG-LS 75°C, ABS Listed, & RoHS Compliant*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to the shield

Carol® Brand Command® Series RG-6 Coaxial Cable

PART NUMBER DESCRIPTION JACKET TYPE

JACKET COLOR/ TEMPERATURE

NOMINAL O.D.

INSULATION TYPE

INSULATION THICKNESS NOM.

IMP. (Ω)

NOMINAL VEL. OF PROP.

NOM. CAP.** pF/FT

NOMINAL ATTENUATION

INCHES mm INCHES mm MHzdB/

100 FT MHzdB/

100 FT

C5775ACS 18 AWG Solid Copper-Clad Steel,

Dual Shielded, CATV Coaxial

Cable

Flame Retardant Low Smoke

Halogen Free Polyolefin PVC

Black/-30°C +75°C

0.274 6.96 Gas Injected Foam

Polyethylene

0.0700 1.78 75±3 83% 16.2 5.00 0.67 550 4.7155.00 1.60 750 5.59

211.00 2.87 870 6.00270.00 3.24 1000 6.54300.00 3.43 1450 8.30350.00 3.72 1800 9.30400.00 4.00 2250 10.60450.00 4.26 3000 11.90

C5814ACS 18 AWG Solid Bare Copper, Dual

Shielded, Video Coaxial Cable

Flame Retardant Low Smoke

Halogen Free Polyolefin PVC

Black/-30°C +75°C

0.274 6.96 Gas Injected Foam

Polyethylene

0.0700 1.78 75 82% 16.2 1.00 0.24 270 2.973.58 0.45 360 3.435.00 0.54 540 4.257.00 0.63 720 4.95

10.00 0.72 750 5.0067.50 1.57 1000 5.8971.50 1.60 1500 7.3388.50 1.75 2000 8.57

100.00 1.84 2250 9.14135.00 2.10 3000 10.67143.00 2.16 4500 13.29180.00 2.42 — —

C8029ACS Element 1 - 18 AWG Solid Bare

Copper, Video Coaxial Cable

Flame Retardant Low Smoke

Halogen Free Polyolefin PVC

Black/-30°C +75°C

0.275 6.99 Gas Injected Foam

Polyethylene

0.0700 1.78 75 83% 16.3 1.00 0.20 200 3.005.00 0.45 400 4.30

10.00 0.64 700 5.8050.00 1.46 900 6.70

100.00 2.10 1000 7.10Element 2 - 2 Cond.

18 AWG 7/.0152” Stranded Bare

Copper, Power Pair

Flame Retardant Low Smoke

Halogen Free Polyolefin PVC

Black/-30°C +75°C

0.186 4.72 -40°C to +105°C

Polypropylene

0.0065 0.17 — — 24** — —

APPROVALS - (UL) c(UL) Listed Communication Cable Type CMG-LS 75°C, ABS Listed, & RoHS Compliant** Capacitance between conductors

Carol® Brand Command® Series Category 5e Cable

PART NUMBER DESCRIPTION

JACKET TYPE

JACKET COLOR/ TEMPERATURE

NOMINAL O.D.INSULATION

TYPE

INSULATION THICKNESS

CONDUCTOR COLOR CODE

INPUT IMP. (Ω)

FRE-QUENCY

PSCAR ACR ATTENUATION PSNEXT NEXT PSELFEXT ELFEXT RL

VALUES ARE EXPRESSED IN dB PER 100m (328 FT) LENGTH

INCHES mm INCHES mm MIN. MIN. MAX. MIN. MIN. MIN. MIN. MIN.

CR5ACS 4 Pair 24 AWG Solid Bare

Copper ScTP Category 5e

Cable

Flame Retardant

Low Smoke Halogen

Free Polyolefin

PVC

Black/-20°C +75°C

0.260 6.60 Polyolefin 0.010 0.25 P1: White/Blue - Blue P2: White/Orange - Orange P3: White/Green - Green P4: White/Brown - Brown

100±15 0.772 1.000 4.000 8.000

10.000 16.000 20.000 25.000 31.250 62.500

100.000

62.2 60.3 49.2 43.0 40.8 36.1 33.5 30.9 28.2 18.4 10.3

65.2 63.3 52.2 46.0 43.8 39.1 36.5 33.9 31.2 21.4 13.3

1.8 2.0 4.1 5.8 6.5 8.2 9.3

10.4 11.7 17.0 22.0

64.0 62.3 53.3 48.8 47.3 44.3 42.8 41.3 39.9 35.4 32.3

67.0 65.3 56.3 51.8 50.3 47.3 45.8 44.3 42.9 38.4 35.3

63.0 60.8 48.7 42.7 40.8 36.7 34.7 32.8 30.9 24.8 20.8

66.0 63.8 51.7 45.7 43.8 39.7 37.7 35.8 33.9 27.8 23.8

— 20.0 23.0 24.5 25.0 25.0 25.0 24.3 23.6 21.5 20.1

APPROVALS - (UL) c(UL) Listed Communication Cable Type CMG-LS 75°C, ABS Listed, & RoHS Compliant

Page 162: Cross-Reference & Online Spec Sheets - Datasheet Archive

151

Audio/Video & Home Entertainment Cable Electronics

Product Description:Command® Series Premium Grade Speaker Cable was designed to offer outstanding performance at an affordable price. The cables are highly flexible and can be used for in-wall installations, making them ideal for use in home theater systems.

The Premium Grade Speaker Cable is available in 250' spools for custom-cut lengths, and in 25-, 50- and 100-foot clam-shells. The packaged cables are ideal for display on pegboard, gondolas or H-frame shelves.

Product Construction: Conductor: •16through12AWGfullyannealed

stranded bare copper conductor per ASTM B-3

Insulation: •Premium-grade,clearPVC •Temperaturerange:-20°Cto+60°C

Applications: •Digitalaudio •Stereosystems •In-wallspeakers •Hometheater

Features: •High-strand,rope-layconductorsgive

the cable extra flexibility •Convenientfootageandpolaritymarkers,

at one-foot intervals to make installation easy

•Paintabletomatchanydécor

Compliances: •NECArticle725TypeCL2 •RoHSCompliantDirective2002/95/EC

Command® Series Premium Grade Speaker Cable NEC Type CL2

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND LENGTH

COLOROF

JACKETPACKAGE

TYPE

PKGPER

CARTON

CARTONWEIGHT(LBS)

CARTONDIMENSIONS(H x W x D)

CARTONCUBE UPC NUMBER

16 AWG CONDUCTORS

C1458.55.90 2 16 66/34 25' Clear Coil 6 6.4 12.5 x 8.1 x 10.0 0.586 0 79407 76307 8

C1458.56.90 2 16 66/34 50' Clear Coil 6 10.4 12.5 x 8.1 x 10.0 0.586 0 79407 76308 5

C1458.57.90 2 16 66/34 100' Clear Coil 6 18.6 15.5 x 8.1 x 10.0 0.727 0 79407 76309 2

C1458.15.90 2 16 66/34 250' Clear Spool 1 8.5 6.6 x 6.6 x 6.3 0.159 0 79407 76273 6

14 AWG CONDUCTORS

C1461.55.90 2 14 105/34 25' Clear Coil 6 8.5 12.5 x 8.1 x 10.0 0.586 0 79407 76310 8

C1461.56.90 2 14 105/34 50' Clear Coil 6 14.5 12.5 x 8.1 x 10.0 0.586 0 79407 76311 5

C1461.57.90 2 14 105/34 100' Clear Coil 6 27.0 15.5 x 8.1 x 10.0 0.727 0 79407 76312 2

C1461.15.90 2 14 105/34 250' Clear Spool 1 11.5 6.6 x 6.6 x 6.3 0.159 0 79407 76274 3

12 AWG CONDUCTORS

C1463.55.90 2 12 259/36 25' Clear Coil 6 11.8 12.5 x 8.1 x 10.0 0.586 0 79407 76313 9

C1463.56.90 2 12 259/36 50' Clear Coil 6 21.4 15.5 x 8.1 x 10.0 0.727 0 79407 76314 6

C1463.15.90 2 12 259/36 250' Clear Spool 1 17.5 13.0 x 6.5 x 9.5 0.464 0 79407 76275 0

®

Page 163: Cross-Reference & Online Spec Sheets - Datasheet Archive

152

Electronics Audio/Video & Home Entertainment Cable

Canadian Standard Association

Product Construction: Conductor: •12,14,16,or18AWGfullyannealed,

stranded bare copper per ASTM B-8

Insulation: •Premium-grade,coIor-coded

polypropylene •Colorcode:Seechartbelow

Jacket: •PVC,commandblue •Temperaturerange:-20˚Cto+60˚C

Applications: •Digitalaudio •Stereosystems •In-wallspeakers •Hometheater •Remotecontrolcircuits •Securitysystems •Bi-ampspeakers

Features: •Flexible

Compliances: •NECArticle725TypeCL3

(UL:60°C) •CSA,CMG,AWMI/IIA/B •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

Vertical Tray Flame Test •PassesCSAFT-4VerticalFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

®

Command® Series Home Entertainment Speaker Cable NEC Type CL3, CSA, CMG, AWM I/II A/B

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION WALL

NOM. JACKET THICKNESS NOMINAL O.D.

INCHES mm INCHES mm INCHES mm

C1700† 2 12 65/30 0.009 0.15 0.021 0.53 0.254 6.45

C1701† 4 12 65/30 0.009 0.15 0.021 0.53 0.299 7.59

C1702† 2 14 41/30 0.009 0.15 0.021 0.53 0.220 5.59

C1703† 4 14 41/30 0.009 0.15 0.021 0.53 0.257 6.53

C1704 2 16 26/30 0.009 0.15 0.021 0.53 0.191 4.85

C1705 4 16 26/30 0.009 0.15 0.021 0.53 0.222 5.64

†CL3, CSA AWM I/II A/B only

Color Code ChartNO. OF COND. COLOR

1 Black

2 Red

3 White

4 Green

Page 164: Cross-Reference & Online Spec Sheets - Datasheet Archive

153

Audio/Video & Home Entertainment Cable Electronics

Product Construction: Conductor: •16-12AWGfullyannealed,stranded

oxygen-free high conductivity bare copper per ASTM B-170

Insulation: •Premium-grade,coIor-coded

polypropylene

Jacket: •PVC,commandblue •Temperaturerange:-20˚Cto+60˚C

Applications: •Digitalaudio •Stereosystems •In-wallspeakers •Hometheater •Remotecontrolcircuits •Securitysystems •Bi-ampspeakers

Features: •Flexible •Highconductivity,oxygen-free

Compliances: •NECArticle725TypeCL3

(UL:60°C) •NECArticle800TypeCM

(UL:60°C) •CSA,CMG,(CSA:80°C,600V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

Vertical Tray Flame Test •PassesCSAFT-4VerticalFlameTest

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Canadian Standard Association

Command® Series OFHC Home Entertainment Speaker Cable CL3(UL),CM(UL)c(UL),CSA,CMG,CSATYPEAWM

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS

NOM. JACKETTHICKNESS NOMINAL O.D.

NOM.C-C

CAP.*pF/ftINCHES mm INCHES mm INCHES mm

C1800** 2 12 105/32 0.009 0.23 0.021 0.53 0.264 6.71 25.5

C1801** 4 12 105/32 0.009 0.23 0.021 0.53 0.311 7.90 25.5

C1802** 2 14 105/34 0.009 0.23 0.021 0.53 0.226 5.74 23.8

C1803** 4 14 105/34 0.009 0.23 0.021 0.53 0.265 6.73 23.8

C1804 2 16 64/34 0.009 0.23 0.021 0.53 0.196 4.98 22.1

C1805 4 16 65/34 0.009 0.23 0.021 0.53 0.228 5.79 22.1

*Capacitance between conductors**NEC Type CL3 and CSA Type AWM Only

Color Code ChartNO. OF COND. COLOR

1 Black

2 Red

3 White

4 Green

®

Page 165: Cross-Reference & Online Spec Sheets - Datasheet Archive

154

Electronics Audio/Video & Home Entertainment Cable

Product Construction: Conductor: •22-12AWGfullyannealedstranded

tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedPVC •Premium-grade,coIor-codedS-RPVC

Jacket: •PVC,white •Temperaturerange:-20°Cto+75°C

Applications: •Digitalaudio •Stereosystems •In-wallspeakers •Suggestedvoltagerating:300volts

Compliances: •NECArticle800TypeCMR

(UL,c(UL):75°C) •NECArticle725TypeCL3

(UL,c(UL):105°C) •UL,c(UL)AWMStyle2587

(UL,c(UL):90°C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

Vertical Tray Flame Test

Packaging and Jacket Colors: •PleaseconsultCustomerServicefor

packaging and color options

®

Command® Series Twisted Pair Speaker Cable CMR(UL)c(UL)orCL3(UL),AWMStyle2587

Color Code Chart C1000A-C1001A

NO. OF COND. COLORS

1 Black

2 Red

C1002A-C1005ANO. OF COND. COLORS

1 Black

2 White

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS

NOM. JACKETTHICKNESS NOMINAL O.D.

NOM.C-C

CAP.*pF/ftINCHES mm INCHES mm INCHES mm

NEC Type CMR

C1000A 2 22 7/30 0.015 0.38 0.025 0.64 0.170 4.32 20.6

C1001A 2 20 7/28 0.013 0.33 0.025 0.64 0.178 4.52 24.5

C1002A 2 18 7/26 0.022 0.56 0.028 0.71 0.235 5.97 21.3

C1003A 2 16 19/.0117 0.023 0.58 0.032 0.81 0.274 6.96 23.5

NEC Type CL3, UL Style 2587 (600V)

C1004A* 2 14 41/30 0.031 0.79 0.032 0.81 0.340 8.64 30.3

C1005A* 2 12 65/30 0.032 0.81 0.035 0.89 0.386 9.80 32.6

*Capacitance between conductors.

Page 166: Cross-Reference & Online Spec Sheets - Datasheet Archive

155

Audio/Video & Home Entertainment Cable Electronics

Product Description:Command® Series Studio Grade Speaker Cable brings sounds to life. It is engineered to deliver the true fidelity of a music signal from the source to the speaker—maintaining the highest signal integrity for ultimate clarity. It is the perfect speaker cable for the dis-criminating audiophile.

Product Construction: Conductor: •16through12AWGfullyannealed

stranded silver-plated conductor per ASTM B-3

Insulation: •Premium-grade,clearbluePVC •Temperaturerange:0°Cto+60°C

Applications: •Digitalaudio •Stereosystems •In-wallspeakers

Features: •Silver-platedconductorlowerselectrical

resistance for superior signal rendition •High-strand,rope-layconductorsgive

the cable extra flexibility •Convenientfootageandpolaritymarkers,

at one-foot intervals to make installation easy

•Paintabletomatchanydécor

Compliances: •NECArticle725TypeCL2 •RoHSCompliantDirective2002/95/EC

Command® Series Studio Grade Speaker Cable NEC Type CL2

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND LENGTH

COLOROF JACKET

PACKAGETYPE

PKGPER

CARTON

CARTONWEIGHT(LBS)

CARTONDIMENSIONS(H x W x D)

CARTONCUBE UPC NUMBER

16 AWG CONDUCTORS

C1558.15.92 2 16 105/36 250’ Clear Blue Spool 1 8.5 6.6 x 6.6 x 6.3 0.159 0 79407 76276 7

14 AWG CONDUCTORS

C1561.15.92 2 14 168/36 250’ Clear Blue Spool 1 11.5 6.6 x 6.6 x 6.3 0.159 0 79407 76280 4

12 AWG CONDUCTORS

C1563.15.92 2 12 259/36 250’ Clear Blue Spool 1 17.5 13.0 x 6.5 x 9.5 0.464 0 79407 76280 4

®

Page 167: Cross-Reference & Online Spec Sheets - Datasheet Archive

156

Electronics Audio/Video & Home Entertainment Cable

Product Construction: Conductor: •24thru12AWGfullyannealedone

bare, one tin stranded copper per ASTMB-174

Insulation/Jacket: •Premium-gradePVC •Colorcode:Seechartbelow

Applications: •Digitalaudio •Hi-fiandstereospeakerwire •Jukeboxes •Notforin-walluse •Hometheater

Compliances: •ULWiresMisc. •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerService

forpackagingandcoloroptions

Product Construction: Conductor: •18AWGtinnedannealedstranded

copper •StrandedtinnedcopperperASTMB-33

Insulation: •Premium-grade,color-codedPVC •Temperaturerange:-30˚Cto+80˚C •Colorcode:Seechartbelow

Applications: •Audiosystems •Notforin-walluse

Compliances: •ULStyle1007(UL:80°C,300V)

Packaging: •1000'(305m)reels

Color Code ChartORDERING

SUFFIXSTOCK COLOR

99 Black-White

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS NOMINAL O.D.

INCHES mm INCHES mm

AWM STYLE 1007 (80°C, 300 V)

C7102A 2 18 7/.0152 0.020 0.51 0.172 4.37

Speaker Wire ULListedorAWMStyle1007

CATALOGNUMBER

NUMBER OF

COND.AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS NOMINAL O.D.

INCHES mm INCHES mm

UL LISTED (60°C)

C1356 2 24 7/32 0.016 0.41 0.058x0.117 1.47x2.79

C1362 2 22 7/30 0.020 0.51 0.070x0.145 1.77x3.68

C1360 2 20 10/30 0.020 0.51 0.085x0.160 2.16x4.06

C1357 2 18 16/30 0.020 0.51 0.083x0.181 2.11x4.60

C1358 2 16 26/30 0.020 0.51 0.105x0.210 2.67x5.33

C1361 2 14 41/30 0.025 0.64 0.125x0.235 3.18x5.69

C1363 2 12 65/30 0.025 0.64 0.154x0.323 3.91x8.20

Color Code ChartORDERING

SUFFIX COLORS

01 Black

02 White

08 Brown

10 Gray

90 Clear

Page 168: Cross-Reference & Online Spec Sheets - Datasheet Archive

157

Audio/Video & Home Entertainment Cable Electronics

Product Construction: Conductor: •12AWGfullyannealedstrandedbare

copper conductor per ASTM B-3

Insulation/Jacket: •Premium-grade,clearSuperflex® PVC •Temperaturerange:-20°Cto+60°C •Colorcode:Seechartbelow

Applications: •Digitalaudio •Hi-fiandstereospeakerwire •Jukeboxes •Notforin-walluse

Compliances: •ULMisc.(UL:120V) •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Product Construction: Conductor: •18AWG,1tinnedand1barecopper

conductor per ASTM B-174

Insulation: •Premium-grade,clearPVC

Jacket: •PVC,clear •Temperaturerange:-20˚Cto+60˚C

Applications: •Digitalaudio •Hi-fiandstereospeakerwire •Jukeboxes

Compliances: •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Superflex® Speaker Wire UL Listed

Color Code ChartORDERING

SUFFIXSTOCK COLOR

90 Clear

Color Code ChartORDERING

SUFFIXSTOCK COLOR

90 Clear

CATALOGNUMBER

NUMBER OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATIONTHICKNESS NOMINAL O.D.

INCHES mm INCHES mm

C1364 2 12 7x37/36 0.060 1.52 0.220x0.456 5.59x11.58

CATALOGNUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

INCHES mm INCHES mm INCHES mm

C6367 2 18 16/30 0.016 0.41 0.025 0.64 0.210 5.33

Page 169: Cross-Reference & Online Spec Sheets - Datasheet Archive

158

Electronics Audio/Video & Home Entertainment Cable

Product Construction:Conductor: •12-18AWGstrandedbarecopper •Twistedpairs

Insulation: •PVC

Jacket: •PVC,matteblack •Highflexibility

Applications: •Recordingstudios •Commercialbroadcastfacilities •Notforin-walluse

Features: •Highdurabilityandlong-lastingservice

Packaging and Jacket Colors: •PleaseconsultCustomerServicefor

packaging, color options and agency approvals

Pro Audio Speaker Wire

CATALOG NUMBER CONDUCTOR & O.D. INSULATION & O.D.

JACKET& O.D.

WEIGHTLBS/Mft

740002 2/C 12 AWG Stranded65/30 Bare Copper

PVC0.136" Nom.

PVC0.365" Nom. 100

740102 2/C 14 AWG Stranded41/30 Bare Copper

PVC0.118" Nom.

PVC0.295" Nom. 75

740202 2/C 16 AWG Stranded26/30 Bare Copper

PVC0.102" Nom.

PVC0.295" Nom. 60

740302 2/C 18 AWG Stranded41/34 Bare Copper

PVC0.079" Nom.

PVC0.235" Nom. 38

CATALOG NUMBER CONDUCTOR & O.D. INSULATION & O.D.

JACKET& O.D.

WEIGHTLBS/Mft

740004 4/C 12 AWG Stranded65/30 Bare Copper

PVC0.136" Nom.

PVC0.463" Nom. 165

740104 4/C 14 AWG Stranded41/30 Bare Copper

PVC0.118" Nom.

PVC0.397" Nom. 107

740204 4/C 16 AWG Stranded26/30 Bare Copper

PVC0.102" Nom.

PVC0.338" Nom. 75

740304 4/C 18 AWG Stranded41/34 Bare Copper

PVC0.079" Nom.

PVC0.283" Nom. 53

NOTE:Cabledwithjutefillersandpapertapeunderjacket.

Color Code ChartNO. OFCOND. COLOR

1 Black

2 White

3 Red

4 Green

Page 170: Cross-Reference & Online Spec Sheets - Datasheet Archive

159

Audio/Video & Home Entertainment Cable Electronics

Product Construction: Conductor: •24thru20AWGfullyannealedstranded

tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-coded

polyethylene(C1333A)orPVC(C1345A) •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester foil

with25%overlap,minimum,foilfacingout

•Strandedtinnedcopperdrainwire

Jacket: •PVC,gray •Temperaturerange:-20°Cto+80°C

Applications: •Audio •Communications •EMIisolatedcircuitsforinstrumentation •Suggestedvoltagerating:300volts

Compliances: •ULStyle2093(UL:60°C,300V) •ULStyle2095(UL:80°C,300V) •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Special Audio, Communication & Instrumentation UL 2095, 2093

Color Code ChartNO. OFCOND. COLOR

Shielded1 Black2 Red

Unshielded1 Natural

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

UL Style 2093, 300 VOLTC1333A 3 2-20

Shielded1-20

Unshielded

10/30

7/28

0.015

0.016

0.38

0.41

0.028 0.71 0.206 5.23 26.0 47.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFCOND. COLOR

Shielded1 Black2 Red3 Green4 Yellow

Unshielded1 Blue2 White

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

UL Style 2095, 300 VOLTC1345A 6 4-24

Shielded2-22

Unshielded

7/32

7/30

0.015 0.38 0.025 0.64 0.230 5.84 32.0 57.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Page 171: Cross-Reference & Online Spec Sheets - Datasheet Archive

160

Electronics Audio/Video & Home Entertainment Cable

Product Construction: Conductor: •22thru18AWGfullyannealedstranded

tinned copper per ASTM B-33

Insulation: •C1331A-Premium-grade,coIor-coded

PVC •C1340A-Premium-grade,coIor-coded

polypropylene •C1343A-Premium-grade,coIor-coded

polyethylene •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester over

twoconductors,25%overlap,minimum,foil facing out

•Strandedtinnedcopperdrainwire

Jacket: •PVC,gray •Temperaturerange:-20°Cto+80°C

Applications: •Audio •Communications •EMIisolatedcircuitsforinstrumentation

Compliances: •NecArticle725TypeCL2

(UL:75°C,150V) •C1331A-ULStyle2095(UL:80°C) •C1340A-ULStyle2835(UL:60°C) •C1343A-ULStyle2094(UL:60°C) •RoHSCompliantDirective2002/95/EC •DesignedtomeetUL70,000BTU

Vertical Tray Flame Test

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Special Audio, Communication & Instrumentation UL 2095, UL 2835, UL 2094, NEC Type CL2

Color Code ChartNO. OFCOND. COLOR

Shielded1 Black

2 Red

Unshielded1 Green

2 White

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

UL Style 2095, NEC Type CL2C1331A 4 2-20

Shielded2-20

Unshielded

7/28 0.016 0.41 0.032 0.81 0.230 5.84 41.0 74.0

UL Style 2835C1340A 4 2-22

Shielded2-22

Unshielded

7/30 0.008 0.20 0.017 0.43 0.161 4.09 29.0 52.0

UL Style 2094C1343A 4 2-20

Shielded2-18

Unshielded

7/28

16/30

0.018 0.46 0.032 0.81 0.259 6.58 27.0 49.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Page 172: Cross-Reference & Online Spec Sheets - Datasheet Archive

161

Audio/Video & Home Entertainment Cable Electronics

Product Construction: Conductor: •22AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-coded

polyethylene •Colorcode:Seechartbelow

Shield: •64%tinnedcopperbraidoveronepair

Jacket: •PVC,gray •Temperaturerange:-20°Cto+60°C

Applications: •Specialaudio •Communicationandcontrol •Instrumentation •Applicationswheretotalisolationof

signal is required •Suggestedvoltagerating:300volts

Compliances: •ULStyle2094(UL:60°C,300V) •RoHSCompliantDirective2002/95/EC •DesignedtomeetULVW-1VerticalWire

Flame Test

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Special Audio, Communication & Instrumentation UL 2094

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C1338A 2 1-22Shielded

1-22Unshielded

7/30 0.015 0.38 0.030 0.76 0.295 7.49 24.0 43.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFPAIRS COLOR

1 Black/Natural

2 Black/Natural

Page 173: Cross-Reference & Online Spec Sheets - Datasheet Archive

162

Electronics Audio/Video & Home Entertainment Cable

Product Construction: Conductor: •23or24AWGsolidbarecopper

Insulation: •Fluorinatedethylenepropylene(FEP) •Highdensitypropylene(HDPE)

Jacket: •Plenum-Flexguard® green •Riser-PVCmaroon

Applications: •SuitableforRGBvideoapplications •DigitalCCTVcameras

Compliances: •NECArticle800TypeCMR(UL),c(UL) •NECArticle800TypeCMP(UL),c(UL)

Packaging: •1000'Pull-Pacs®

•ContactCustomerServiceforadditionalpackaging options

Low Skew 4-Pair UTP NECTypeCMR/CMP(UL),c(UL)

CATALOG NUMBER

AWG SIZE

NOMINAL DCR

NOMINAL O.D.

(INCHES)

INSULATION MATERIAL

NOMINALIMPEDANCE

OHMSPROPAGATION DELAY SKEW

NOMINALATTENUATION BELDEN

PART NO.INCHES mm MHz dB/328 ft.

E3842S CMP

24 AWG Solid Bare

Copper

27.4 Ω/Mft

0.185 Fluorinated Ethylene Propylene(FEP)

100 2.2 ns/328 ft. 1 4 8 10 16 20 25

31.25 62.50 100 155 200

250* 300* 350*

2.0 4.1 5.8 6.5 8.2 9.3

10.4 11.7 17.0 22.0 28.1 32.0 36.4 41.0 44.8

7987P

0.035 0.9

E1842S CMR

24 AWG Solid Bare

Copper

27.4 Ω/Mft

0.185 High Density Propylene(HDPE)

100 2.2 ns/328 ft. 1 4 8 10 16 20 25

31.25 62.50 100 155 200

250* 300* 350*

2.0 4.1 5.8 6.5 8.2 9.3

10.4 11.7 17.0 22.0 28.1 32.0 36.4 41.0 44.8

7987R

0.035 0.9

E3843S CMP

23 AWG Solid Bare

Copper

22.0 Ω/Mft

0.200 Fluorinated Ethylene Propylene(FEP)

100 2.2 ns/328 ft. 1 4 8 10 16 20 25

31.25 62.50 100 155 200 250

300* 350*

2.0 3.8 5.3 6.0 7.6 8.5 9.5

10.7 15.4 19.8 25.2 29.0 32.8 35.2 39.8

7989P

0.040 1.0

E1843S CMR

23 AWG Solid Bare

Copper

22.0 Ω/Mft

0.213 High Density Propylene(HDPE)

100 2.2 ns/328 ft. 1 4 8 10 16 20 25

31.25 62.50 100 155 200

250* 300* 350*

2.0 3.8 5.3 6.0 7.6 8.5 9.5

10.7 15.4 19.8 25.2 29.0 32.8 35.2 39.8

7989R

0.040 1.0

*For information only.

Color Code ChartNO. OF PAIRS COLOR

1 White/Blue Stripe and Blue

2 White/Orange Stripe and Orange

3 White/Green Stripe and Green

4 White/Brown Stripe and Brown

Page 174: Cross-Reference & Online Spec Sheets - Datasheet Archive

163

Audio/Video & Home Entertainment Cable Electronics

CATALOG NUMBER

SAFETY RATING BINDING OR JACKET

CONSTRUCTION

710021 Riser Binding 4 Carol® Brand Cat 5e UTP

810021 Plenum Binding 4 Carol® Brand Cat 5e UTP

710022 Riser Binding 6 Carol® Brand Cat 5e UTP

810022 Plenum Binding 6 Carol® Brand Cat 5e UTP

710023 Riser Binding 4 Carol® Brand Cat 5e ScTP

810023 Plenum Binding 4 Carol® Brand Cat 5e ScTP

710024 Riser Binding 6 Carol® Brand Cat 5e ScTP

810024 Plenum Binding 6 Carol® Brand Cat 5e ScTP

710010 Riser Jacket 2 Carol® Brand Cat 5e UTP and 2 RG6 Quad Smart Home coax

710011 Riser Jacket 2 Carol® Brand Cat 5e UTP, 2 RG6 Quad Smart Home coax and 2 simplex multimode fiber cables

710017 Riser Binding 2 Carol® Brand Cat 5e UTP and 2 RG6 Quad Smart Home coax

710018 Riser Binding 2 Carol® Brand Cat 5e UTP, 2 RG6 Quad Smart Home coax and 2 simplex multimode fiber cables

Theabovelistingsareforstockcables.Customconfigurationsareavailable.Informationissubjecttochangewithoutnotice.ConsultCustomerServiceforavarietyofalternateconstructionsforspecificapplications.

DATA TRANSMISSION PERFORMANCE FOR CAT 5E CABLES

FREQUENCY(MHZ)

INSERTION LOSSTYPICAL • MAX*

(dB/100m)

NEXTTYPICAL • MIN*

(dB)

PSNEXTTYPICAL • MIN*

(dB)

ACRTYPICAL • MIN*

(dB/100m)

PSACRTYPICAL • MIN*

(dB/100m)

ELFEXTTYPICAL • MIN*

(dB/100m)

PSNEXTTYPICAL • MIN*

(dB/100m)

RETURNLOSS MIN

(dB)

1 19.3•22.0 51.9•35.3 43.8•32.3 32.6•13.3 24.5•10.3 43.7•23.8 38.8•20.8 20.1

*Max/min measurements match TIA/EIA 568 B-2 standards

Product Construction: Fiber: •Multimodeorsinglemodefiberswith

easily strippable 900µm tight buffering colored per TIA/EIA 598

•Cabledwitharamidyarnstrengthmember and jacketed to meet appropriate standards

Coax: •QuadshieldRG6coaxwithcopper-clad

steel center conductor, either foamed PE(riser)orFEP(plenum)dielectricandoverall PVC jacket

Twisted Pair: •Unshielded or shielded twisted pair that

meets or exceeds all TIA/EIA 568 B-2 standards for Carol® Brand Cat 5e

Binder: •Helicallywoundpolyesterbinder

Overall Jacket (Optional): •Riser-ratedversionsuseaflame-

retardant PVC

Applications: •SmartWrap™ cables are several different

cables available with either helical binding or overall jacketing to allow simultaneous pulling of multiple cables. Configurations include combinations of Cat 5e UTP or ScTP, RG6 video/data quad shield coax and optical fiber cables. Plenum and riser versions available

Features: •Manycablescanbepulledatonce—

faster installation •TIA/EIA568B-2Crosstalk-compliant •Simplifiescablemanagement •Excellentforresidentialapplications

Compliances: •NECArticle800CMR,CSAFT-4riser •NECArticle800CMP,CSAFT-6plenum

Packaging: •PleasecontactCustomerServicefor

packaging and color options

ELECTRICAL CHARACTERISTICS FOR CAT 5E CABLESDC ResistanceDCR UnbalancedMutual Capacitance

≤9.38Ohms/100Meters•28.6Ohms/1000Feet≤5%≤55.8pF/m•17pF/ft

Input ImpedancePropagationDelay(Skew)Velocity of Propagation

100Ohms±15%@1-100MHz45 nanoseconds/100 meters max72%plenum/69%riser

ELECTRICAL CHARACTERISTICS FOR RG6 CABLESCapacitanceCharacteristic Impedance

≤53.2pF/m•16.2pF/ft75 Ohms

Attenuation(dB/100ft)Velocity of Propagation

0.21@1MHz•6.04dB@1000MHz83%riser

SmartWrap™ Bundled Cable MultipleCableTypesDependingOnApplicationUpto6Cables/JacketedandUnjacketed

Page 175: Cross-Reference & Online Spec Sheets - Datasheet Archive

164

Electronics Audio/Video & Home Entertainment Cable

CapacitanceCharacteristic Impedance

≤53.2pF/m•16.2pF/ft75 r/Ohms

Attenuation(dB/100ft)Velocity of Propagation

0.21@1MHz•6.04dB@1000MHz83%riser

Product Construction: Conductor: •20AWGfullyannealedsolidtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-coded

polypropylene

Shield: •100%Flexfoil® aluminum/polyester with

25%overlap,minimum,foilfacingout •Solidtinnedcopperdrainwire

Jacket: •Permaline® high-density polyethylene,

black •Temperaturerange:-20°Cto+80°C

Applications: •Suitablefordirectburial •Outdooruses •100%shieldedcablewhereRFshielding

is required •Suggestedvoltagerating:350volts

Features: •Permaline® jackets resist deterioration •Sunlight-resistant •Highlydurablejacket

Compliances: •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Direct Burial, Audio & Communication

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C2509A 2 20 Solid 0.013 0.33 0.037 0.94 0.190 4.83 25.0 44.0

C2510A 3 20 Solid 0.013 0.33 0.039 0.99 0.205 5.21 22.0 40.0

C2511A 10 20 Solid 0.013 0.33 0.039 0.99 0.310 7.87 20.5 37.0

*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Page 176: Cross-Reference & Online Spec Sheets - Datasheet Archive

165

Audio/Video & Home Entertainment Cable Electronics

Product Construction: Conductor: •20AWGfullyannealedstrandedtinned

copper per ASTM B-33 •Twistedpairs

Insulation: •Premium-grade,coIor-coded

polypropylene •Colorcode:Seechartbelow

Shield: •100%Flexfoil® aluminum/polyester with

25%overlap,minimum,foilfacingin •Strandedtinnedcopperdrainwire

each pair •Individuallyshieldedpairs

Jacket: •Permaline® high-density polyethylene,

black •Temperaturerange:-20°Cto+80°C

Applications: •Suitablefordirectburial •Outdooruses •Applicationswheretotalisolationof

signal is required •Suggestedvoltagerating:350volts

Features: •Permaline® jackets resist deterioration •Sunlight-resistant

Compliances: •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Direct Burial, Audio & Communication

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C6061A 3 20 10/30 0.013 0.33 0.047 1.19 0.340 8.64 22.0 39.0

C6062A 6 20 10/30 0.013 0.33 0.047 1.19 0.442 11.23 22.0 39.0*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Color Code ChartNO. OFPAIRS COLOR

1 Black paired with Red

2 Black paired with White

3 Black paired with Green

4 Black paired with Blue

5 BlackpairedwithYellow

6 Black paired with Brown

Page 177: Cross-Reference & Online Spec Sheets - Datasheet Archive

166

Electronics Audio/Video & Home Entertainment Cable

Product Construction: Conductor: •24AWGstrandedtinnedcopper •Twistedpairs

Insulation: •High-densityfoamedpolyethylene

Shield: •Individuallyshieldedpairswith24AWG

drain wire •Overallfoilshieldwith18AWGdrain

wire

Jacket: •PVC,matteblack •High-flex,flame-retardant

Applications: •Digitalaudio •Interconnectionandaudiocomponents

for console board equipment used in recording studios, radio and television stations, and post-production facilities

•Soundsysteminstallations

Features: •Highimpedance,78%velocityand

low capacitance providing error-free transmissions over extended distances

•PVCjacketingcompoundforultimatecosmetics, durability and flexibility

•Jacketedpairscanbesplitoutofoveralljacket for any length without use of heat-shrink tubing

•Individualpairjacketsarecolor-coded and number-printed for easy identification

Compliances: •NECArticle725TypeCL2 •NECArticle800TypeCM •Meets/exceedsrequirementsofAudio

EngineeringSociety(AES)andEuropeanBroadcastUnion(EBU)

Packaging and Jacket Colors: •PleaseconsultCustomerServicefor

packaging and color options

Digital Audio Snake Cable AES/EBU110OhmMulti-PairIndividuallyShielded&Jacketed, NEC Type CM/CL2

CATALOG NUMBER CONDUCTOR

INSULATION & O.D.

SHIELD(COV.)

JACKET& O.D.

WT. #/m

IMPED. OHMS

CAPAC. pF/ft.

7406011/PR 24 AWG

Stranded 7/32 Tinned Copper

HD-Cellular PE 0.066” Nom.

Individual Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.176" Nom. 13.5 110 12.5

7406044/PR 24 AWG

Stranded 7/32 Tinned Copper

HD-Cellular PE 0.066” Nom.

Individual Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.525" Nom. 100 110 12.5

7406088/PR 24 AWG

Stranded 7/32 Tinned Copper

HD-Cellular PE 0.066” Nom.

Individual Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.700" Nom. 183 110 12.5

74061212/PR 24 AWG

Stranded 7/32 Tinned Copper

HD-Cellular PE 0.066” Nom.

Individual Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.850" Nom. 250 110 12.5

74061616/PR 24 AWG

Stranded 7/32 Tinned Copper

HD-Cellular PE 0.066” Nom.

Individual Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 1.000" Nom. 370 110 12.5

74062020/PR 24 AWG

Stranded 7/32 Tinned Copper

HD-Cellular PE 0.066” Nom.

Individual Foil w/ 24 AWG DrainOverall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 1.100" Nom. 425 110 12.5

NOTE:GeneralCablemanufacturestheabovecablesinawiderangeofalternateAWGsizes,paircountsandjacketcolors.Please consult Customer Service for details.

Page 178: Cross-Reference & Online Spec Sheets - Datasheet Archive

167

Audio/Video & Home Entertainment Cable Electronics

Product Construction: Conductor: •24AWGstrandedtinnedcopper •Twistedpairs

Insulation: •Polyolefin

Shield: •Individuallyshieldedpairswith24AWG

drain wire •Overallfoilshield24AWGdrainwire

Jacket: •PVC,matteblack •High-flex,flame-retardant

Applications: •Analogaudio •Linelevelmicrophone •Interconnectionandaudiocomponents

for console board equipment used in recording studios, radio and television stations, and post-production facilities

•Soundsysteminstallations

Features: •PVCjacketingcompoundforsuperior

cosmetics, durability and flexibility •Individuallyshieldedandjacketedpairs

with an overall shield •Individualpairjacketsalpha-numerically

numbered for easy identification

Compliances: •NECArticle725TypeCL2 •NECArticle800TypeCM

Packaging and Jacket Colors: •PleaseconsultCustomerServicefor

packaging and color options

Analog Audio Snake Cable 70OhmLowCapacitanceMulti-PairIndividuallyShielded&Jacketed,NECTypeCM/CL2

CATALOGNUMBER CONDUCTOR

INSULATION& O.D.

SHIELD(COV.)

JACKET& O.D.

WT.#/m

IMPED.OHMS

CAPAC.pF/ft

STRANDED CONDUCTORS

740501 1/PR 24 AWG Stranded7/32 Tinned Copper

Polyolefin0.024” Nom.

Overall Foil w/24 AWG Drain

Overall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.137" Nom. 11 65 24

740504 4/PR 24 AWG Stranded7/32 Tinned Copper

Polyolefin0.024” Nom.

Overall Foil w/24 AWG Drain

Overall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.385" Nom. 64 65 24

740508 8/PR 24 AWG Stranded7/32 Tinned Copper

Polyolefin0.024” Nom.

Overall Foil w/24 AWG Drain

Overall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.490" Nom. 107 65 24

740512 12/PR 24 AWG Stranded7/32 Tinned Copper

Polyolefin0.024” Nom.

Overall Foil w/24 AWG Drain

Overall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.610" Nom. 160 65 24

740516 16/PR 24 AWG Stranded7/32 Tinned Copper

Polyolefin0.024” Nom.

Overall Foil w/24 AWG Drain

Overall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.680" Nom. 205 65 24

740520 20/PR 24 AWG Stranded7/32 Tinned Copper

Polyolefin0.024” Nom.

Overall Foil w/24 AWG Drain

Overall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.700" Nom. 248 65 24

740528 28/PR 24 AWG Stranded7/32 Tinned Copper

Polyolefin0.024” Nom.

Overall Foil w/24 AWG Drain

Overall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.820" Nom. 340 65 24

740542 42/PR 24 AWG Stranded7/32 Tinned Copper

Polyolefin0.024” Nom.

Overall Foil w/24 AWG Drain

Overall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 1.050" Nom. 485 65 24

740552 52/PR 24 AWG Stranded7/32 Tinned Copper

Polyolefin0.024” Nom.

Overall Foil w/24 AWG Drain

Overall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 1.150" Nom. 595 65 24

NOTE:GeneralCablemanufacturestheabovecablesinawiderangeofalternateAWGsizes,paircountsandjacketcolors.Please consult Customer Service for details.

Page 179: Cross-Reference & Online Spec Sheets - Datasheet Archive

168

Electronics Audio/Video & Home Entertainment Cable

Product Construction:Conductor: •24AWGstrandedtinnedcopper •Twistedpairs

Insulation: •Polyolefin

Shield: •Individuallyshieldedpairswith24AWG

drain wire •Overallfoilshield24AWGdrainwire

Jacket: •PVC,matteblack •High-flex,flame-retardant

Applications: •Linelevelmicrophone •Interconnectionandaudiocomponents

for console board equipment used in recording studios, radio and television stations, and post-production facilities

•Soundsysteminstallations

Features: •PVCjacketingcompoundforsuperior

cosmetics, durability and flexibility •Individuallyshieldedpairsarecolor-

coded for easy identification

Compliances: •NECArticle725TypeCL2 •NECArticle800TypeCM

Packaging and Jacket Colors: •PleaseconsultCustomerServicefor

packaging and color options

CATALOG NUMBER

CONDUCTOR INSULATION & O.D.

SHIELD(COV.)

JACKET& O.D.

WT. #/m

IMPED. OHMS

CAPAC. pF/ft

7407011/PR 24 AWG

Stranded 7/32 Tinned Copper

Polyolefin0.044" Nom.

Overall Foil w/24 AWG Drain

Overall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.137” Nom. 11 65 24

7407044/PR 24 AWG

Stranded 7/32 Tinned Copper

Polyolefin0.044" Nom.

Overall Foil w/24 AWG Drain

Overall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.280” Nom. 39 65 24

7407066/PR 24 AWG

Stranded 7/32 Tinned Copper

Polyolefin0.044" Nom.

Overall Foil w/24 AWG Drain

Overall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.330” Nom. 55 65 24

7407088/PR 24 AWG

Stranded 7/32 Tinned Copper

Polyolefin0.044" Nom.

Overall Foil w/24 AWG Drain

Overall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.350” Nom. 69 65 24

7407099/PR 24 AWG

Stranded 7/32 Tinned Copper

Polyolefin0.044" Nom.

Overall Foil w/24 AWG Drain

Overall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.380” Nom. 76 65 24

74071212/PR 24 AWG

Stranded 7/32 Tinned Copper

Polyolefin0.044" Nom.

Overall Foil w/24 AWG Drain

Overall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.425” Nom. 96 65 24

74071616/PR 24 AWG

Stranded 7/32 Tinned Copper

Polyolefin0.044" Nom.

Overall Foil w/24 AWG Drain

Overall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.490” Nom. 130 65 24

74072020/PR 24 AWG

Stranded 7/32 Tinned Copper

Polyolefin0.044" Nom.

Overall Foil w/24 AWG Drain

Overall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.540” Nom. 158 65 24

74072828/PR 24 AWG

Stranded 7/32 Tinned Copper

Polyolefin0.044" Nom.

Overall Foil w/24 AWG Drain

Overall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.655” Nom. 221 65 24

74074242/PR 24 AWG

Stranded 7/32 Tinned Copper

Polyolefin0.044" Nom.

Overall Foil w/24 AWG Drain

Overall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.775” Nom. 327 65 24

74075252/PR 24 AWG

Stranded 7/32 Tinned Copper

Polyolefin0.044" Nom.

Overall Foil w/24 AWG Drain

Overall Foil w/ 18 AWG Drain

FR-PVC MatteFinish 0.845” Nom. 391 65 24

NOTE:GeneralCablemanufacturestheabovecablesinawiderangeofalternateAWGsizes,paircountsandjacketcolors.Please consult Customer Service for details.

Analog Audio Snake Cable 70 Ohm Low Capacitance Multi-Pair Individually Shielded, NEC Type CM/CL2

Page 180: Cross-Reference & Online Spec Sheets - Datasheet Archive

169

Audio/Video & Home Entertainment Cable Electronics

Product Construction: Conductor: •20or24AWGstrandedbarecopper

Insulation: •Duallayerofsemi-conductivePVCover

polyethylene

Shield: •36AWGbarecopperbraidorspiral

Jacket: •Highqualityaudio(HQA)PVC,matte

black •Superiorflexibility

Applications: •Guitars •Basses •Keyboardsandotherinstrumentsto

amplifiers, mixers and effects pedals •Alloutdoorsignalprocessinggear

Features: •Lowcapacitancetoprovideexcellent

structural return loss characteristics •Speciallyformulatedvinylsleeving

reduces triboelectric charges which cause microphonic handling noise in high-gain amplification applications

Packaging and Jacket Colors: •PleaseconsultCustomerServicefor

packaging and color options

Guitar/Instrument Cable

CATALOG NUMBER CONDUCTOR

INSULATION & O.D.

SHIELD(COV.)

JACKET& O.D.

WT. #/m

IMPED. OHMS

CAPAC. pF/ft.

7436011/C 20 AWG

Stranded 41/36 Bare Copper

0.038" Poly0.010" SemiConductive

Vinyl

36AWG95%Nom.Bare Copper Braid

“HQA” PVC 0.240

Nom. Black34 47 33

7436021/C 20 AWG

Stranded 41/36 Bare Copper

0.038" Poly0.010" SemiConductive

Vinyl

36AWG65%Nom.Bare Copper Spiral

“HQA” PVC 0.240

Nom. Black34 47 33

7436031/C 20 AWG

Stranded 41/36 Bare Copper

0.038" Poly0.010" SemiConductive

Vinyl

36AWG95%Nom.Bare Copper Braid

“HQA” PVC 0.240

Nom. Black34 47 33

7436041/C 20 AWG

Stranded 22/34 Bare Copper

0.025" Poly0.010" SemiConductive

Vinyl

36AWG65%Nom.Bare Copper Spiral

“HQA” PVC 0.235

Nom. Black36 47 33

7436051/C 24 AWG

Stranded 7/32 Bare Copper

0.040" Poly0.010" SemiConductive

Vinyl

36AWG95%Nom.Bare Copper Spiral

“HQA” PVC 0.235

Nom. Black30 47 33

Page 181: Cross-Reference & Online Spec Sheets - Datasheet Archive

170

Electronics Audio/Video & Home Entertainment Cable

Product Construction: Conductor: •20-24AWGstrandedbarecopper •Twistedpairs

Insulation: •PVCorpolyethylene

Shield: •Braidorspiral,bareortinnedcopper

(choiceofshieldingconfigurations)

Jacket: •Highqualityaudio(HQA)PVC,matte

black •Superiorflexibility

Applications: •General-purposeaudioapplications •Homeentertainment •Musicalinstruments

Features: •Twistedconductorconstruction

minimizes effects of EMI •Preciseapplicationoffillermaintains

mechanical durability to resist annoying handling noise

•Braidshieldguardsagainstcrosstalkand EMI while minimizing capacitive reactance, which causes hum and buzz

•HighstrandconductorplusHQAjacketresults in ultimate flexibility

Packaging and Jacket Colors: •PleaseconsultCustomerServicefor

packaging and color options

Ultra Flexible, Low Impedance 2-Conductor Microphone Cable

CATALOGNUMBER CONDUCTOR

INSULATION& O.D.

SHIELD(COV.)

JACKET& O.D.

WT.#/m

IMPED.OHMS

CAPAC.pF/ft

743701 2/C 24 AWG Stranded105/44 Bare Copper

PVC0.045" Nom.

80%Nom.BareCopper Braid

“HQA” PVC 0.176"Nom. Black

22 65 30

743704 2/C 24 AWG Stranded41/40 Bare Copper

Polyethylene0.050" Nom.

95%TinnedCopper Braid

“HQA” PVC 0.194"Nom. Black

23 80 20

743705 2/C 24 AWG Stranded16/36 Bare Copper

Polyethylene0.050" Nom.

95%BareCopper Spiral

“HQA” PVC 0.225"Nom. Black

29 80 20

743706 2/C 22 AWG Stranded26/36 Bare Copper

Polyethylene0.062" Nom.

85%BareCopper Braid

“HQA” PVC 0.232"Nom. Black

34 85 18

743707 2/C 20 AWG Stranded41/36 Bare Copper

Polyethylene0.074" Nom.

85%BareCopper Braid

“HQA” PVC 0.262"Nom. Black

40 80 20

Page 182: Cross-Reference & Online Spec Sheets - Datasheet Archive

171

Audio/Video & Home Entertainment Cable Electronics

Product Construction: Conductor: •24AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-coded

polypropylene •Colorcode:Seechartbelow

Shield: •Conductivetapeappliedoverthecore •100%Flexfoil® aluminum/polyester,

25%overlap,minimum,foilfacingin •Strandedtinnedcopperdrainwire

Jacket: •PVC,black •Temperaturerange:-20°Cto+75°C

Applications: •ElectroniccircuitswhereRFshieldingis

required •Radiotransmitters •Soundsystems •Recordingstudios •Suggestedvoltagerating:300volts

Features: •Excellentshieldingtoreducenoise

Compliances: •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Multi-Conductor, Flexfoil® Shield

Color Code ChartNO. OFCOND. COLOR

1 Black

2 Red

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C1228A 2 24 19/36 0.008 0.20 0.022 0.56 0.135 3.43 27.0 48.5*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Page 183: Cross-Reference & Online Spec Sheets - Datasheet Archive

172

Electronics Audio/Video & Home Entertainment Cable

Product Construction: Conductor: •18and20AWGfullyannealedstranded

tinned copper per ASTM B-33

Insulation: •Premium-grade,coIor-codedrubber

insulation •Colorcode:Seechartbelow

Shield: •ClearMylar® wrap •80%tinnedcopperbraid •Cottonwrap

Jacket: •Rubber,black •Temperaturerange:-20°Cto+60°C

Applications: C1300, C1301: •High-impedancemicrophones •Broadcastandstudiouse •Communicationandaudiosystem •Shieldedpowersupplies •Suggestedvoltagerating:300volts

C1302: •Low-impedancemicrophones •Studiouse •Controlcircuits •Videoandaudiointerconnectingcables •Shieldedpowersupplies •Suggestedvoltagerating:300volts

Features: •Precisionengineeredtotransmitclear,

noise-free signals •Minimizeselectrical“hum” •Braidshieldprovidesextraflexibility

Compliances: •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Multi-Conductor, Rubber, Braid Shield Microphone Cable High and Low Impedance

Color Code ChartNO. OFCOND. COLOR

1 White

2 Black

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D. NOM. CAP.*

pF/ftINCHES mm INCHES mm INCHES mm

C1300 1 20 26/34 0.042 1.07 0.035 0.89 0.230 5.84 42.0

C1301 1 18 41/34 0.040 1.02 0.035 0.89 0.240 6.10 46.0

C1302 2 20 26/34 0.020 0.51 0.035 0.89 0.270 6.86 50.0

*Capacitance between one conductor and other conductors connected to shield

Page 184: Cross-Reference & Online Spec Sheets - Datasheet Archive

173

Audio/Video & Home Entertainment Cable Electronics

Multi-Conductor, Spiral Shield

Product Construction: Conductor: •24AWGannealedstrandedbarecopper

per ASTM B-3

Insulation: •Premium-grade,coIor-codedPVC •Colorcode:Seechartbelow

Shield: •85%spiral-tinnedcopper

Jacket: •PVC,black •Temperaturerange:-20°Cto+90°C

Applications: •ElectroniccircuitswhereRFshieldingis

required •Radiotransmitters •Soundsystems •Recordingstudios •Suggestedvoltagerating:300volts

Features: •Spiralshieldprovidesextraflexibility •Excellentshieldingtoreducenoise

Compliances: •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Color Code ChartNO. OFCOND. COLOR

1 White

2 Green

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOM. CAP.*pF/ft

INCHES mm INCHES mm INCHES mm A B

C1226A 2 24 105/44 0.012 0.30 0.030 0.76 0.176 4.47 43.0 77.0*A – Capacitance between conductors*B – Capacitance between one conductor and other conductors connected to shield

Page 185: Cross-Reference & Online Spec Sheets - Datasheet Archive

174

Electronics Audio/Video & Home Entertainment Cable

Product Construction: Conductor: •22AWGfullyannealedstrandedtinned

copper per ASTM B-33

Insulation: •Premium-grade,coIor-coded

polyethylene •Fillerswhererequired •Colorcode:Seechartbelow

Shield: •80%tinnedcopperbraid

Jacket: •PVC,gray •Temperaturerange:-20°Cto+75°C

Applications: •Low-impedancemicrophones •Suggestedvoltagerating:1000volts

Features: •Flexlife® jacket provides extreme

flexibility •Highabrasionresistance •Outstandingappearance

Compliances: •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Color Code ChartNO. OFCOND. COLOR

1 White

2 Black

Multi-Conductor, Braid Shield Low Impedance

CATALOG NUMBER TYPE

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D. NOM. CAP.*

pF/ftINCHES mm INCHES mm INCHES mm

C1322A Low Imped.

2 22 16/34 0.025 0.64 0.025 0.64 0.239 6.07 31.0

*Capacitance between one conductor and other conductors connected to shield

Page 186: Cross-Reference & Online Spec Sheets - Datasheet Archive

175

Audio/Video & Home Entertainment Cable Electronics

Product Construction: Conductor: •18and16AWGfullyannealedstranded

tinned copper per ASTM B-33

Insulation: •Premium-grade,color-codedrubber •Colorcode:Seechartbelow

Shield: •ClearMylar® wrap •80%braidtinnedcopper •Cottonwrap

Jacket: •Carolprene®, black •Temperaturerange:-20°Cto+60°C

Applications: C1201: •High-impedancemicrophones •Broadcastandstudiouse •Communicationandaudiosystems •Suggestedvoltagerating:300volts

C1202, C1602: •Low-impedancemicrophones •Studiouse •Controlcircuits •Videoandinterconnectingcables •Shieldedpowersupplies •Suggestedvoltagerating:300volts

Features: •Precisionengineeredtotransmitclear,

noise-free signals •Minimizeselectrical“hum” •Resistanttooil,acid,sunlight,abrasion

and aging •Excellentnoiserejection

Compliances: •RoHSCompliantDirective2002/95/EC

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Microphone Cable, Multi-Conductor, Carolprene®, Braid Shield High and Low Impedance

Color Code ChartNO. OFCOND. COLOR

1 White

2 Black

CATALOG NUMBER

NO. OFCOND.

AWGSIZE

COND.STRAND

NOM. INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D. NOM. CAP.*

pF/ftINCHES mm INCHES mm INCHES mm

C1201 1 18 41/34 0.040 1.02 0.035 0.89 0.240 6.10 46.0

C1202 2 18 41/34 0.020 0.51 0.035 0.89 0.295 7.49 61.0

C1602 2 16 65/34 0.025 0.64 0.035 0.89 0.335 8.51 55.0

*Capacitance between one conductor and other conductors connected to shield

Page 187: Cross-Reference & Online Spec Sheets - Datasheet Archive

176

Electronics Audio/Video & Home Entertainment Cable

Product Construction: Conductor: •Element#1: 4 auxiliary conductors

(usedastwo) Size: 20 AWG; stranded tinned

annealed copper Insulation: High-density polyethylene

O.D.:0.060"nom.(1.53mm)

•Element#2: 2 single conductors Size: 24 AWG; stranded tinned

annealed copper Insulation: High-densitypolyethylene:

0.045"nom.(1.12mm)

•Element#3: Singlemodefiberoptic

•Element#4: Strength member in core Size: 16 AWG; stranded

insulated galvanized steel cable

Color: White O.D.: 0.083"nom.(2.1mm)

Fillers: •Fibrillatedpolypropyleneasneededfor

roundness

Binder: •Papertapewith25%overlap

Braid Shield: •Flexiblydesignedbraidshieldwith85%

nom. coverage

Jacket: •FlexiblePVC(HQA) •Temperaturerange:-40˚Cto+75˚C •Humidity0to95% •TPRruggedizedoutdoorversion

Jacket Marking: •HELIX/HITEMPP/NXXXXXX*SINGLE-

MODE FIBER OPTIC/ELECTRICAL HD CAMERACABLE(RU)AWMSTYLE21059 80C 300V VW-1

Cable Weight: •87.6lbs/Mftnom.(130.8Kg/KM)

Performance: •Meets/exceedsSMPTE-311M-1998

Connector: •LEMOconnector(callLEMOformore

informationat800.444.5366) •SMPTEstandard304videoconnector

Compliances: •ULSubject758 •AWMStyle21059

Packaging: •PleaseconsultCustomerServicefor

packaging and color options

*XXXXXX-indicatespartnumber

SMPTE-311 Hybrid Fiber Optic/Copper Camera Cable

CATALOGNUMBER

AUXILIARYCONDUCTOR SIGNAL COND.

OPTICAL FIBER

STRENGTHMEMBER SHIELD JACKET

742608 (4)20AWG26/34 Strand Tinned Cu

High-density Polyethylene

Insul. O.D. 0.060"

(2)25AWG7/33 Strand Tinned Cu

High-density Polyethylene

Insul. O.D. 0.045"

(2)9.5MicronSingle-Mode

14 AWG 19/27Strand

Galvanized Steel

95%BraidTinned CU

Flexible PVC(HQA)

Black 0.362"O.D. 9.20 mm

574608 (4)20AWG26/34Strand Tinned Cu

High-density Polyethylene

Insul. O.D. 0.060"

(2)25AWG7/33 Strand Tinned Cu

High-density Polyethylene

Insul. O.D. 0.045"

(2)9.5MicronSingle-Mode

14 AWG 19/27Strand

Galvanized Steel

95%BraidTinned CU

RuggedizedOutdoor TPRBlack 0.362"O.D. 9.20 mm

NOTE:GeneralCablemanufacturestheabovecablesinawiderangeofalternateAWGsizes,paircountsandjacketcolors.Please consult Customer Service for details.

Cable Characteristics

ELEMENT NUMBER (1) AUXILIARY CONDUCTORS (2) SIGNAL CONDUCTORS (3) SINGLEMODE FIBER OPTIC

CONDUCTOR DCR 35.29Ω/Kmmax@20˚C 97.5ΩKmmax@20˚C Mode Field Data 9.5+/-1Micron

DC LOOP RESISTANCE 43Ω/Kmmax@20˚C 184ΩKmmax@20˚C Cladding Data 125+/-1Micron

INSULATION RESISTANCE 10,000Ω/Kmmax@20˚C 10,000ΩKmmax@20˚C Buffer Material Thermoplastic

DIELECTRIC STRENGTH

1750VRMS@20˚C,60Hz for 1 min

1750VRMS@20˚C,60Hz for 1 min

VOLTAGE RATING 300V Max 300V Max

COLOR C1, C3-BlackC2, C4-White

C1-RedC2-Gray

C1-Blue C2-Yellow

TYPICAL CROSS SECTIONJacket

Shield

4/Auxiliary Cond

2/Optical Fibers

Strength Member

2/Signal Cond

Page 188: Cross-Reference & Online Spec Sheets - Datasheet Archive

177

Audio/Video & Home Entertainment Cable Electronics

Product Construction: Applications: •IdealforTVbroadcastandCCTV

applications •Suitedforcontrolling,poweringand

transmitting audio and video signals for TV cameras

•Additionalusesincluderemotecontrol,monitor and cue line systems

Features: •Providesexcellentcircuitisolation •Superiordurabilitycharacteristicsina

variety of environmental conditions

Packaging and Jacket Colors: •PleasecontactCustomerServicefor

packaging and color options

Electronic News Gathering/Field Production Camera Cable

CATALOGNUMBER

COAXIALCOMPONENT SIGNAL PAIR POWER PAIR JACKET

742605 1/C 25 AWG Stranded 7/33Bare Copper

High-density Polyethylene Insulation90%BareCopperBraid

PVCJacketO.D. 0.175" Nom.

1/PR 24 AWGStranded 19/36 Bare

CopperPolyethyleneInsulation+Foil24 AWG Drain

O.D. 0.140" Nom.

1/PR 22 AWGStranded 26/36 Bare

CopperPVC Insulation

O.D. 0.100" Nom.

Matte Black"HQA" PVCO.D. .495"

Nom.

NOTE:GeneralCablemanufacturestheabovecablesinawiderangeofalternateAWGsizes,paircountsandjacketcolors.Please consult Customer Service for details.

Page 189: Cross-Reference & Online Spec Sheets - Datasheet Archive

178

Electronics

General Cable has a variety of wire and cable available for special applications. This section includes an array of products from our Fluorobus flat bus ground/power distribution cable to high-speed serial interface cable, known as Fire Wire, and computer cables.

For more information on these cables or for other special applications, please contact your General Cable sales representative.

Index Page

Armored Electronics Products Guide 179-180

Wind Energy 181

Fluorobus Cable 182

Fire Wire 183

Computer Cable 184

Composite Data and Control Cable 185

Specialty Cable 9

Page 190: Cross-Reference & Online Spec Sheets - Datasheet Archive

179

General Cable now offers the capability to armor virtually any Carol® Brand Electronics cable. This rugged exterior and protection allows for the installation of almost any Electronics cable in markets with the toughest and most rigorous building code requirements. Cables placed in armor are not only acceptable for use in Riser applications, but according to NEC Article 300.22(B), these cables are acceptable in Plenum applications as well.

The process to convert a standard Carol Brand Electronics cable to an armored cable is simple and is explained on the back of this bulletin. All you really need to know is: 1) which cable you want to armor, 2) whether you want steel or aluminum interlock armor, and 3) what put-up lengths you would like to receive product on.

General Cable continues to expand its Carol Brand Electronics product offering to allow our customers to participate in more diversified markets. You can always Demand Better...Expect More™ with General Cable Carol Brand Electronics cables. We manufacture over 1,300 standard electronic cables that we ship direct from stock, and we have the technical staff and design expertise to meet any customer cable requirement.

Special Application Cable

Hook-Up Wire

Plenum Cable

Coaxial Cable

Microphone Cable

Computer Cable

General Purpose Cable

Multi-Conductor Communication & Control Cable

Multi-Paired Communication & Control Cable

Fire Alarm Cable

Sound & Security Cable

Armored Electronics Products

E L E C T R O N I C S P R O D U C T B U L L E T I N

Page 191: Cross-Reference & Online Spec Sheets - Datasheet Archive

180

HOW TO ARMOR YOUR ELECTRONICS Step 1 - Find a Carol Brand part # in the catalog that you want to armor. Step 2 - Build your Carol Brand Armored part #

❶ Pick the root part # you want to armor. ❷ Pick the put-up length that you want. ❸ Pick the color of jacket for the wire. ❹ Pick the type of armor you want.

Armored Part # looks like: C2409A.41.02ADescription is now: 14 AWG / 2 Conductor, Unshielded, White Jacket Communication Cable in Aluminum Armor on a 1000' Reel.

Armor Codes & Charts

Products in the Electronics Catalog that can be armored:

Section 2 - Communication & Control Cable, Multi-Conductor Section 6 - Fire Alarm / Life Safety Cable Section 3 - Communication & Control Cable, Multi-Paired Section 7 - Sound, Alarm, & SecuritySection 4 - Computer Cable Section 8 - Audio / Home Entertainment CableSection 5 - Coaxial Cable

Carol® Brand Communication & Control Cable, Multi-Conductor, Unshielded

CATALOG NUMBER

NO. OF COND. AWG SIZE

COND. STRAND.

NOM. INSULATION THICKNESS

NOMINAL JACKET THICKNESS

NOMINAL O.D.NOM. C-C CAP. pF/FTINCHES mm INCHES mm INCHES mm

C2409A 2 14 19/.0147 0.030 0.81 0.032 0.81 0.260 6.81 30.5

Armor Sizing ChartCABLE DIAMETER ARMOR STRIP WIDTH CLEARANCE (IN) ARMOR O.D. (IN) ARMOR WEIGHT (LBS/mFT)

0.190 3/8" 0.060 0.350 29.000

0.250 3/8" 0.100 0.450 38.600

0.300 3/8" 0.100 0.500 43.400

0.350 3/8" 0.100 0.550 48.300

0.400 3/8" 0.100 0.600 53.100

0.450 3/8" 0.100 0.650 57.900

0.500 3/8" 0.100 0.700 62.700

0.550 3/8" 0.100 0.750 67.600

0.600 3/8" 0.100 0.800 72.400

0.650 3/8" 0.100 0.850 77.200

0.700 1/2" 0.100 0.900 109.400

0.750 1/2" 0.100 0.950 115.800

0.800 1/2" 0.100 1.000 122.300

Armor CodesTYPE CODE

Aluminum A

Steel S

Wire Jacket ColorCODE COLOR

01 BLACK

02 WHITE

03 RED

04 ORANGE

05 YELLOW

06 GREEN

07 DARK BLUE

08 BROWN

09 MAROON

10 GRAY

11 ANTIQUE GOLD

12 IVORY

13 PINK

NOTE: Additional colors available

Put-Up CodesSIZE CODE

250' 35

500' 38

1000' 41NOTE 1: Consult factory for additional put-up lengthsNOTE 2: Product provided on reels

C2409A❶

Root #

41❷

Put-Up

02❸

Cable Jacket Color

A❹

Armor Indicator

Armored Electronics Products

Page 192: Cross-Reference & Online Spec Sheets - Datasheet Archive

181

Delivering the renewable power of

Wind Energy

Answering the CallWind. It’s plentiful, renewable, and clean. That’s why wind power has increased more than fivefold since the beginning of the 21st century, taking center stage as the fastest growing alternative energy source in the global arena. With increased energy demand and mounting political pressure, alternative energy mandates are cropping up all over the world, with many countries calling for significant growth in wind generation capacity over the next decade. General Cable has the experience, the innovation, and the global presence to answer that call.

Since the first modern wind turbine was developed in the 1980s, General Cable has been committed to delivering the renewable power of wind energy through ground-breaking wire and cable technologies. General Cable has developed cables that are flexible yet tough enough to withstand the continuous motion of today’s wind turbines. Our commitment to providing the highest quality and reliable products lowers cost and extends turbine operating life by reducing failures and maintaining continuous power.

Knowing No BoundariesWind knows no boundaries, and neither does General Cable. From Brazil, Mexico, and the U.S. to Germany, Spain, China, India, and Australia, initiatives are in place to increase wind power, with targets to support a significantly higher percentage of energy needs.

With a solid presence in North America, South America, Europe, Asia, Africa, the Middle East, and Oceania, General Cable has the geographical presence to focus on region-specific wind power needs and to meet domestic and global specifications. At the same time, General Cable’s

One Company approach means we have a keen ability to unite and leverage our broad knowledge and shared resources to bring innovative solutions to the entire world.

Setting the BenchmarkWhether it is terrestrial wind farms requiring direct buried cables or offshore wind farms requiring high-performance submarine cables, General Cable has one of the most diverse and expansive ranges of products to meet virtually every application in the wind power industry. From fiber optic and bare overhead conductors to underground URD and low-voltage power, control, and electronic cables, General Cable offers the full array of cables needed for wind turbines to generate, distribute, and transmit energy.

As the benchmark in the wire and cable industry, renowned for our engineering and material development capabilities, General Cable is positioned to rapidly respond to the needs of the evolving wind farm market with next-generation cabling systems.

Call us today at 888.593.3355 for additional information.

Wind knows no boundaries,

and neither does General Cable.

Page 193: Cross-Reference & Online Spec Sheets - Datasheet Archive

182

Electronics Specialty Cable

Applications: •Ideallysuitedforlow-voltageprimary

and secondary power distribution in electronic and data processing equipment. High-speed, solid-state circuits require relatively high currents with low voltage. For this reason, it is essential that DC power distribution lines have low inductance, low resistance and high capacitance. More important, tightly bundled or laminated flat cable source-and-return circuits deliver lower impedance and higher capacitance by one to two orders of magnitude, compared to round wire circuits with equal resistance.

•Thissystemcanserveasalow-costflexible alternative to laminated bus bars. The Fluorobus low-profile routing capability is a useful packaging feature, and its large surface area (relative to round wire conductor of equal resistance) provides improved heat dissipation, minimizes voltage drop and results in a higher current rating.

•Thisflatconductorcircuitdelivers superiorEMI/RFIperformance,both as a source and as a receiver.

Temperature Rating: •-50°Cto+150°C

Voltage Rating: •300voltsand600volts(AWM)available

(consult Customer Service)

Dielectric Constant: •2.6

Dielectric Strength: •900VRMS

Packaging and Color: •PleaseconsultCustomerServicefor

packaging and color options

CATALOG NUMBER

CONDUCTOR INSULATION FINISHEDDIMENSIONS

DCR POWER RATING

SP00C0011010 Flat Solid BC0.010" x 0.987"

Tetzel®

(ETFE) 0.028 x 1.022 0.82 Ohms per1000 ft. @ 25˚C

32 Amps Nom.100 Amps Max.

SP00C0012010 Flat Solid BC0.020" x 0.987"

Tetzel®

(ETFE) 0.037 x 1.022 0.41 Ohms per1000 ft. @ 25˚C

64AmpsNom.100 Amps Max.

Informationissubjecttochangewithoutnotice.

Fluorobus Cable Flat Bus Ground / Power Distribution Cable

Features BenefitsLow Profile: Conserves space

Flexible: Ease of routing

Large Surface Area:

Improvedheatdissipationminimizes voltage dropHigh current rating

182

Page 194: Cross-Reference & Online Spec Sheets - Datasheet Archive

183

Specialty Cable Electronics

CATALOG NUMBER

Z028C0061110

SIGNAL PAIRS POWERCONDUCTOR

OVERALL SHIELDING

OVERALLJACKET

SIGNAL PR.

IMPED.

SIGNAL PR.

CAPAC.NOM.MHz

ATTENUATIONDB 100'

2/C #227/36TC

Foam Poly InsulationIndividual

Foil & BraidNo.1:Red,Green

No. 2: Blue, Orange

2/C #227/36TC

PolyolefinInsulation

Black, White

Aluminum/Mylar®

(Foil Out)+95%Braid

Flexible PVC

110 Ohms

12.5 pF/ft

1000.0 37 55

* Apple Computer trademark

Applications: •Transportdigitaldataforcomputersand

for professional and consumer electronic products

•Personalcomputers •Audio/image/videoproducts •Printers/scanners •Discarrays •Digitalvideocameras/displays/recorders

Compliances: •UL:AWM20276 •80˚C30VVW-1 •CSA:PCCFT1

Packaging and Jacket Colors: •PleaseconsultCustomerServicefor

packaging and color options

Fire Wire* IEEE1394High-SpeedSerialInterface

Page 195: Cross-Reference & Online Spec Sheets - Datasheet Archive

184

Electronics Specialty Cable

Applications: •GeneralCablemanufacturesadiverse

array of multiconductor cables for computers and the interconnection of their peripherals. Today’s need for speed and signal capacity demands the most in cable materials and construction. Our state-of-the-art manufacturing allows us to control impedance, minimize signal skew and provide the proper shielding for applicationsfromUSBandFireWireright up through the latest Fiber Channel protocols. Whether your applications require parallel or serial signal transmission, General Cable has the technology to fill your needs.

Packaging and Jacket Colors: •PleaseconsultCustomerServicefor

packaging and color options

PART NUMBER APPLICATION DESCRIPTION

EO28P0501510EO24C0045510EO26C0045510EO28C0045510EO30C0045510EO28P0181510

HIPPIFiber ChannelFiber ChannelFiber ChannelFiber ChannelIEEE-1284

50 Pair, 28 AWG, 105 Ohm2 Pair “Quad”, 24 AWG, 150 Ohm2Pair“Quad”,26AWG,150Ohm2 Pair “Quad”, 28 AWG, 150 Ohm2 Pair “Quad”, 30 AWG, 150 Ohm18Pair,28AWG,O/AFoil+Braid

Test&Measurement,DataTransfer,ElectronicPublishing,VideoConferencing,SoundSynthesizers,PCWorkstations,Multi-Media,ConsumerElectronics,CableTV,DigitalCameras/Camcorders,etc.

PART NUMBER APPLICATION DESCRIPTION

Z028C0066110 IEEE-1394(FireWire) 2 Pair, 28 AWG, 2/C 22 AWG

ISDN,CD-ROMDrives,Modems,Scanners,Printers,AudioI/ODevices,Keyboards,TelephoneISDN,etc.

PART NUMBER APPLICATION DESCRIPTION

ZO28C0042010ZO28C0042210ZO28C0042410ZO28C0042610ZO28C0042810

UniversalSerialBusUniversalSerialBusUniversalSerialBusUniversalSerialBusUniversalSerialBus

1 Pair, 28 AWG, 2/C 20 AWG1 Pair, 28 AWG, 2/C 22 AWG1 Pair, 28 AWG, 2/C 24 AWG1Pair,28AWG,2/C26AWG1 Pair, 28 AWG, 2/C 28 AWG

VideoMonitors,CRTs,Workstations

PART NUMBER APPLICATION DESCRIPTION

ZO28C0101120 Monitor 10/C 3/Coax 28 AWG, 7/C 28 AWG

Computer Cable Mainframes, Data Transfer, Tape Drives, File Servers, Disc Drives, Workstations, Disc Arrays, Personal Computers, etc.

Page 196: Cross-Reference & Online Spec Sheets - Datasheet Archive

185

Specialty Cable Electronics

Product Construction: Conductor: •22AWGand18AWGfullyannealed

stranded tinned copper per ASTM B-33

Insulation: •22AWG-foamFEP

18AWG-plenumPVC •Colorcode:Seechartbelow

Pair Shield (22 AWG): •100%Flexfoil® aluminum/polyester foil

with25%overlap,minimum •Strandedtinnedcopperdrainwire

Jacket: •PlenumPVC,naturalorasrequested •Temperaturerange:-20°Cto+75°C

Applications: •Multimediasystems •Dataandcontrolcircuits •Suggestedvoltagerating:300volts

Compliances: •NECArticle800 •DesignedtomeetNFPA262andCSA

FT-6SteinerTunnelFireTestsforPlenumApplications

Features: •Fire-retardant,low-smokejacket

Packaging: •PleasecontactCustomerServicefor

packaging and color options

Color Code Chart

AWG COLOR

22 Blue & White

18 Black&Red

CATALOG NUMBER

NO. OFPAIRS

AWGSIZE

COND.STRAND

NOM.INSULATION THICKNESS

NOM. JACKET THICKNESS NOMINAL O.D.

NOMINAL CAP. *pF/ft

INCHES mm INCHES mm INCHES mm A B

22 AWG SHIELDED PAIR AND 18 AWG UNSHIELDED PAIR WITH OVERALL JACKET

C8125 1 each (22 7/30 TC 0.020 0.51) 0.015 0.381 0.195 4.95 13 (22) 35.0

(18 16/30TC 0.009 0.23) 30 (18)

*A - Capacitance between conductors*B - Capacitance between one conductor and other conductors connected to shield

Composite Data and Control Cable NECTypeCMP(UL)c(UL)

Page 197: Cross-Reference & Online Spec Sheets - Datasheet Archive

186

Electronics

Index Page

Insulation & Jacket Properties 187

Decimal Conversion Factors 188

Unit Conversion Factors 189

Temperature Conversion Chart 190

Conduit Capacity Chart 191

Coax Connector Cross Reference 192-199

AWG Conductor Chart 200

Cable Design Equations— Braid Shield 201

Coaxial Cable 202

Balanced Pair 203

Engineering Prefixes 204

Glossary 205-215

Abbreviations & Acronyms 216-218

Product Finders— Hook-Up Wire 219

Multi-Conductor Cable 220-222

Multi-Paired Cable 223-225

NEC/CEC Substitution Chart 226-227

Agency Symbols 228

Agency Approval Index 229

Put-Ups and Color Codes 230

Applications Index 231-233

Belden-to-General Cable Carol® Brand Cross Reference Index 234-239

Part Number Index 240-246

Notes 247

Technical Information 10

As technology becomes more complex, specifying wire and cable products to meet system performance demands becomes more time-consuming and complex.

Today’s system designer must be aware not only of the general transmission line types, but also of the myriad of materials available to meet specific environmental or electrical performance criteria.

This technical section is presented to aid in the selection of materials and designs which will best suit the combination of hardware and transmission media.

For technical questions regarding specific transmission designs or applications, please contact General Cable’s Engineering Department.

Page 198: Cross-Reference & Online Spec Sheets - Datasheet Archive

TYPICAL PROPERTIES OF COMMON INSULATING MATERIALS

PARAMETER PVC PE PP XLPE NYLON FEP TFEBUTYL

RUBBERSILICONERUBBER TPR

Specific Gravity 1.37 0.92 0.89 0.93-1.18 1.09 2.16 2.17 1.40 1.24 1.16-1.20

Dielectric Constant(a) 60 Hz(b) 1000 Hz

6.05.0

2.262.26

2.6 3.03.0

4.64.5

2.152.15

2.12.1

4.14.0

3.33.1

2.82.8

Dielectric Strength, v/mil(a) 0.010” wall(b) 0.040” wall

1800800

21001050

850450

-700

1000470

2000950

2000950

700500

600400

625

Tensil Strength, PSI x 1000 1.5-3.8 1.4-2.4 2.9-4.5 1.8-2.5 8.8-11.9 2.3-3.1 2.0-6.0 0.5-1.5 0.6-1.2 2.3

Service Temp, Range, °C -55/+105 -90/+90 -40/+105 -80/+75 -55/+105 -90/+200 -90/+260 -40/+90 -80/+200 -55/+90

Elongation, % 200-375 350-550 700 250-400 150-380 200-330 200-500 200-400 125-400 500

Water Absorption, % in 24 hr <0.75 <0.02 <0.02 <0.01 2.5 <0.01 <0.01 <1.0 <1.0 <0.6

Flame Resistance

SelfExtinguishing

SupportsFlame

SupportsFlame

SlowFlame

SelfExtinguishing

Non-Flammable

Non-Flammable

SlowBurning

Slow(Non-Cond.

Ash)Flammable

Ozone Resistance Excellent Good Excellent Good Good Excellent Excellent Excellent Excellent Excellent

Flexibility Good Good Good Good-Fair Good-Fair Good Good Excellent Excellent Excellent

Abrasion Resistance Good Good Fair Excellent Excellent Excellent Excellent Poor Poor Good-Fair

Acid Resistance Excellent Excellent Excellent Excellent Excellent Poor Excellent Excellent Good Excellent

Base Resistance Excellent Excellent Excellent Excellent Excellent Excellent Excellent Good Good Excellent

Hydraulic Fluid Resistance Good-Fair Fair-Poor Fair Good-Fair Good-Fair Excellent Excellent Poor Fair-Poor Poor

Organic Solvent Resistance Fair-Poor Poor Fair Fair Good-Fair Excellent Excellent Good-Fair Poor Poor

NOTE: The above is representative of performance. For specific compound performance, consult Customer Service.

TYPICAL PROPERTIES OF COMMON JACKETING MATERIALS

PARAMETER PVC PE NYLON FEP TFESILICONERUBBER NEOPRENE

POLY-URETHANE TPR

Specific Gravity 1.37 0.92 1.09 2.16 2.17 1.24 1.52 1.3 1.16-1.20

Tensil Strength, PSI x 1000 1.5-3.8 1.4-2.4 8.8-11.9 2.3-3.1 2.0-6.0 0.6-1.2 2.5-4.0 >3.5 2.3

Elongation, % 200-375 350-550 150-380 200-330 200-500 125-400 300-500 540-700 500

Service Temp, Range, °C -55/+105 -80/+75 -55/+105 -90/+200 -90/+200 -80/+200 -65/+90 -65/+75 -55/+90

Ozone Resistance Excellent Good Good Excellent Excellent Excellent Excellent Good Excellent

Weatherability Good-Fair Excellent-Good Fair-Poor Excellent Excellent Excellent Good Good Excellent

Flame Resistance

SelfExtinguishing

SupportsFlame Flammable

Non-Flammable

Non-Flammable

Slow-Burn(Non-Cond.

Ash)

SelfExtinguishing Slow Burn Flammable

Flexibility Good Good Good-Fair Good Good Excellent Excellent Excellent Excellent

Abrasion Resistance Good Good Excellent Excellent Excellent Poor Excellent Excellent Good-Fair

Acid Resistance Excellent Excellent Poor Excellent Excellent Poor Good Fair Excellent

Base Resistance Excellent Excellent Excellent Excellent Excellent Good Good Fair Excellent

Hydraulic Fluid Resistance Good-Fair Fair-Poor Good-Fair Excellent Excellent Fair-Poor Good Poor Good

Organic Solvent Resistance Fair-Poor Poor Good-Fair Excellent Excellent Poor Good Poor Poor

Resistance to Tearing Good Good Excellent Good Good Fair Good Excellent Good-Fair

NOTE: The above is representative of performance. For specific compound performance, consult Customer Service.

187

Technical Information Electronics

Insulation & Jacket Properties

Page 199: Cross-Reference & Online Spec Sheets - Datasheet Archive

FRACTIONS, DECIMALS AND MILLIMETER CONVERSION CHARTFRACTIONS OF AN INCH EQUIVALENTS FRACTIONS OF AN INCH EQUIVALENTS

64 32 16 8 4 2 DECIMALS mm 64 32 16 8 4 2 DECIMALS mm

12345 6789

10

1112131415 1617181920 2122232425 2627282930 3132

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

1

2

3

4

5

6

7

8

1

2

3

4

1

2 1

0.0160.0310.0470.0630.078

0.0940.1090.1250.1410.156

0.1720.1880.2030.2190.234

0.2500.2660.2810.2970.313

0.3280.3440.3590.3750.391

0.4060.4220.4380.4530.469

0.4840.500

0.400.791.191.591.98

2.382.783.183.573.97

4.374.765.165.565.95

6.356.757.147.547.94

8.338.739.139.539.92

10.3210.7211.1111.5111.91

12.3012.70

3334353637

3839404142

4344454647

4849505152

5354555657

5859606162

6364

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

9

10

11

12

13

14

15

16

5

6

7

8

3

4 2

0.5160.5310.5470.5630.578

0.5940.6090.6250.6410.656

0.6720.6880.7030.7190.734

0.7500.7660.7810.7970.813

0.8280.8440.8590.8750.891

0.9060.9220.9380.9530.969

0.9841.000

13.1013.4913.8914.2914.68

15.0815.4815.8816.2716.67

17.0717.4617.8618.2618.65

19.0519.4519.8420.2420.64

21.0321.4321.8322.2322.62

23.0223.4223.8124.2124.61

25.0025.40

188

Electronics Technical Information

Decimal Conversion Factors

Page 200: Cross-Reference & Online Spec Sheets - Datasheet Archive

CONVERSION FACTORS

UNIT X CONSTANT = UNIT UNIT X CONSTANT = UNIT

British Thermal Unit (BTU)British Thermal Unit (BTU)British Thermal Unit (BTU)

centimeters (cm)centimeters (cm)centimeters (cm)centimeters (cm)centimeters (cm)

circular mils (cmil)circular mils (cmil)circular mils (cmil)circular mils (cmil)

cubic centimeter (cm3)cubic centimeter (cm3)cubic centimeter (cm3)cubic centimeter (cm3)

cubic foot (ft3)cubic foot (ft3)cubic inch (in3)cubic inch (in3)cubic inch (in3)

cubic meter (m3)cubic meter (m3)cubic meter (m3)

feet (ft)feet (ft)feet (ft)feet (ft)feet (ft)feet (ft)feet (ft)

feet/pound (ft/lb)foot-pound (ft-lb)foot-pound (ft-lb)foot-pound (ft-lb)

778.01054.35

0.2930.032808

0.39370.00001

0.01010.0

0.000645160.0000007854

0.000506710.7854

0.0000353140.0610230.000001

0.000264171728.0

28317.847 0.000578700.000016387

16.3870641000000.035.314666

264.170.00018939

0.3333312

0.000304800.3048030.480304.80

0.000671970.001285

1.3560.1383

foot-pound (ft-lb)joules (j)

watt-hours (w-hr)feet (ft)

inches (in)kilometers (km)

meters (m)millimeters (mm)

circular millimetersinches2 (in2)

square millimeters (mm2)mils2

cubic foot (ft3)cubic inch (in3)

cubic meter (m3)gallons (gal)cubic in (in3)

cubic centimeter (cm3)cubic feet (ft3)

cubic meter (m3)cubic centimeter (cm3)

centimeter (cm)cubic foot (ft3)gallons (gal)miles (mi)yards (yd)inches (in)

kilometer (km)meters (m)

centimeters (cm)millimeters (mm)

meters/grams (m/g)British Thermal Unit (BTU)

joules (j)kilogram/meter (kg/m)

gallons (gal)gallons (gal)gallons (gal)gallons (gal)

grams (g)gram/centimeter3 (gm/cm3)

horsepower (hp)horsepower (hp)horsepower (hp)

inch (in)inch (in)inch (in)inch (in)inch (in)inch (in)inch (in)joules (j)joules (j)liters (l)

meters (m)meters (m)meters (m)meters (m)miles (mi)miles (mi)miles (mi)

millimeters (mm)millimeters (mm)millimeters (mm)millimeters (mm)millimeters (mm)millimeters (mm)

watts (w)watts (w)watts (w)

watt-hours (w-hr)

3.7854110.13368

231.03785.411

15.4320.036127533013.26

550.0745.7

0.0271780.083333

0.000025400.025400

2.5400051425.4000514

1000.00.000948

107

61.023741.093611

3.280833339.37100.0

1760.05280.01.6093

0.00328080.03937

0.0010.01

39.37011000.044.25

0.7375620.0013413.414462

liters (l)cubic foot (ft3)cubic inch (in3)

cubic centimeter (cm3)grains

pounds/in3 (lb/in3)ft-lb/minft-lb/secwatts (w)yards (yd)

feet (ft)kilometer (km)

meter (m)centimeter (cm)millimeter (mm)

milsBritish Thermal Unit (BTU)

ergscubic inch (in3)

yard (yd)feet (ft)inch (in)

centimeter (cm)yards (yd)

feet (ft)kilometer (km)

feet (ft)inch (in)

meters (m)centimeters (cm)

milsmicrons (µ)ft-lb/minute

ft-lb/sechorsepower

British Thermal Unit (BTU)

189

Technical Information Electronics

Unit Conversion Factors

Page 201: Cross-Reference & Online Spec Sheets - Datasheet Archive

˚C ˚F ˚C ˚F ˚C ˚F ˚C ˚F ˚C ˚F

-45.0-44.4-43.9-43.3-42.8-42.2-41.7-41.1-40.6-40.0

-39.4-38.9-38.3-37.8-37.2-36.7-36.1-35.6-35.0-34.4

-33.9-33.3-32.8-32.2-31.7-31.1-30.6-30.0-29.4-28.9

-28.3-27.8-27.2-26.7-26.1-25.6-25.0-24.4-23.9-23.3

-22.8-22.2-21.7-21.1-20.6-20.0-19.4-18.9-18.3-17.8

-49.0-48.0-47.0-46.0-45.0-44.0-43.0-42.0-41.0-40.0

-39.0-38.0-37.0-36.0-35.0-34.0-33.0-32.0-31.0-30.0

-29.0-28.0-27.0-26.0-25.0-24.0-23.0-22.0-21.0-20.0

-19.0-18.0-17.0-16.0-15.0-14.0-13.0-12.0-11.0-10.0

-9.0-8.0-7.0-6.0-5.0-4.0-3.0-2.0-1.00.0

-17.2-16.7-16.1-15.6-15.0-14.4-13.9-13.3-12.8-12.2

-11.7-11.1-10.6-10.0-9.4-8.9-8.3-7.8-7.2-6.7

-6.1-5.6-5.0-4.4-3.9-3.3-2.8-2.2-1.7-1.1

-0.60.00.61.11.72.22.83.33.94.4

5.05.66.16.77.27.88.38.99.4

10.0

1.02.03.04.05.06.07.08.09.0

10.0

11.012.013.014.015.016.017.018.019.020.0

21.022.023.024.025.026.027.028.029.030.0

31.032.033.034.035.036.037.038.039.040.0

41.042.043.044.045.046.047.048.049.050.0

10.611.111.712.212.813.313.914.415.015.6

16.116.717.217.818.318.919.420.020.621.1

21.722.222.823.323.924.425.025.626.126.7

27.227.828.328.929.430.030.631.131.732.2

32.833.333.934.435.035.636.136.737.237.8

51.052.053.054.055.056.057.058.059.060.0

61.062.063.064.065.066.067.068.069.070.0

71.072.073.074.075.076.077.078.079.080.0

81.082.083.084.085.086.087.088.089.090.0

91.092.093.094.095.096.097.098.099.0

100.0

38.338.939.440.040.641.141.742.242.843.3

43.944.445.045.646.146.747.247.848.348.9

49.450.050.651.151.752.252.853.353.954.4

55.055.656.156.757.257.858.358.959.460.0

60.661.161.762.262.863.363.964.465.065.6

101.0102.0103.0104.0105.0106.0107.0108.0109.0110.0

111.0112.0113.0114.0115.0116.0117.0118.0119.0120.0

121.0122.0123.0124.0125.0126.0127.0128.0129.0130.0

131.0132.0133.0134.0135.0136.0137.0138.0139.0140.0

141.0142.0143.0144.0145.0146.0147.0148.0149.0150.0

66.166.767.267.868.368.969.470.070.671.1

71.772.272.873.373.974.475.075.676.176.7

77.277.878.378.979.480.080.681.181.782.2

82.883.383.984.485.085.686.186.787.287.8

88.388.989.490.090.691.191.792.292.893.3

151.0152.0153.0154.0155.0156.0157.0158.0159.0160.0

161.0162.0163.0164.0165.0166.0167.0168.0169.0170.0

171.0172.0173.0174.0175.0176.0177.0178.0179.0180.0

181.0182.0183.0184.0185.0186.0187.0188.0189.0190.0

191.0192.0193.0194.0195.0196.0197.0198.0199.0200.0

To use this chart, find your known temperature (°F) in the shaded column.

190

Electronics Technical Information

TEMPERATURE CONVERSION FORMULA

°C = 5 (°F -32) 9

°F = 9 °C +32 5

Temperature Conversion Chart

Page 202: Cross-Reference & Online Spec Sheets - Datasheet Archive

Conduit Trade Size 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 3 1/2 4I.D. Inches 0.622 0.824 1.049 1.380 1.610 2.067 2.731 3.356 3.834 4.334Internal Area, In2 0.304 0.533 0.864 1.496 2.036 3.356 5.858 8.846 11.545 14.7531 Conductor (53% fill) 0.161 0.283 0.458 0.793 1.079 1.778 3.105 4.688 6.119 7.8192 Conductors (31% fill) 0.094 0.165 0.268 0.464 0.631 1.040 1.816 2.742 3.579 4.573Conductors (40% fill) 0.122 0.213 0.346 0.598 0.814 1.342 2.343 3.538 4.618 5.901Cable OD

InchesCable

Area In2 Numbers listed below are based on the 2008 NEC (40% fill ) for 3 or more non-lead covered cables.

0.100 0.008 15 26 43 76 104 170 244 375 504 6480.125 0.012 9 17 27 48 66 109 156 240 322 4140.150 0.018 6 11 19 33 46 75 108 166 224 2880.175 0.024 5 8 14 24 34 55 79 122 164 2110.200 0.031 3 6 10 19 26 42 81 93 126 1620.225 0.040 3 5 8 15 20 33 48 74 99 1280.250 0.049 1 4 6 12 16 27 39 60 80 1030.275 0.059 1 3 5 10 13 22 32 49 66 850.300 0.071 1 2 4 8 11 18 27 41 56 720.325 0.083 1 1 4 7 9 16 23 35 47 610.350 0.096 1 1 3 6 8 13 19 30 41 520.375 0.110 1 1 3 5 7 12 17 26 35 460.400 0.126 1 1 2 4 6 10 15 23 31 400.425 0.142 1 1 1 4 5 9 13 20 27 350.450 0.159 1 1 1 3 5 8 12 18 24 320.475 0.177 0 1 1 3 4 7 10 17 22 280.500 0.196 0 1 1 3 4 6 9 15 20 250.525 0.216 0 1 1 2 3 6 8 13 18 230.550 0.238 0 1 1 1 3 5 8 12 16 210.575 0.260 0 1 1 1 3 5 7 11 15 190.600 0.283 0 0 1 1 2 4 6 10 14 180.625 0.307 0 0 1 1 2 4 6 9 12 160.650 0.332 0 0 1 1 1 4 5 8 11 150.675 0.358 0 0 1 1 1 3 5 8 11 140.700 0.385 0 0 1 1 1 3 5 7 10 130.725 0.413 0 0 1 1 1 3 4 7 9 120.750 0.442 0 0 1 1 1 3 4 6 8 110.775 0.472 0 0 0 1 1 2 4 6 8 100.800 0.503 0 0 0 1 1 2 3 5 7 100.825 0.535 0 0 0 1 1 1 3 5 7 90.850 0.567 0 0 0 1 1 1 3 5 6 80.875 0.601 0 0 0 1 1 1 3 4 6 80.900 0.636 0 0 0 1 1 1 3 4 6 80.925 0.672 0 0 0 1 1 1 2 4 5 70.950 0.709 0 0 0 1 1 1 2 4 5 70.975 0.747 0 0 0 1 1 1 1 3 5 61.000 0.785 0 0 0 1 1 1 1 3 5 61.025 0.825 0 0 0 0 1 1 1 3 4 61.050 0.866 0 0 0 0 1 1 1 3 4 51.075 0.908 0 0 0 0 1 1 1 3 4 5

Notice: 1. The reader is cautioned to consult the 2008 NEC for specific informatioon regarding conduit fill. 2. This Conduit Capacity Chart should only be used as a guide when attempting to estimate conduit fill. 3. For additional information, the reader should refer to the 2008 National Electrical Code, Chapter 9.

191

Technical Information Electronics

Conduit Capacity Chart

Page 203: Cross-Reference & Online Spec Sheets - Datasheet Archive

BNC TYPE CONNECTORSCAMBRIDGE GEM LRC RF INDUSTRIES TROMPETER

CATALOG NUMBER BNC CRIMP PLUG BNC COMPRESSION PLUG SNAP-N-SEAL BNC CRIMP PLUG BNC CRIMP PLUG

RG 6/UC3521 CPMC-68-36 — — RFB-1707-Q1 105-1516-9

C3523 CPMC-68-36 302-510CS — — 105-1516-9

C3524 CPMC-68-36 302-510CS — — 105-1516-9

C3525 CPMC-68-36 — — — 105-1516-9

C5760 CPMC-68-45 — — RFB-1707-Q1 105-1516-9

C5761 CPMC-68-45 302-5CSQS SNS6BNC — UPL20-34

C5775 CPMC-68-45 302-5CSQS SNS6BNC — 105-1153-9

C5776 CPMC-68-45 — SNS6BNC — 105-1153-9

C5777 CPMC-68-45 — SNS6BNC RFB-1707-Q 105-1153-9

C5778 CPMC-68-45 — SNS6BNC RFB-1707-Q 105-1153-9

C5785 CPFI-UG88-3 (TWIST ON) 302-5CSQS SNS6QSBNC — UPL20-41

C5802 CPMC-68-45 — SNS6BNC RFB-1707-Q UPL20-41

C5804 CPMC-68-45 — SNS6BNC RFB-1707-Q UPL20-41

C5814 CPMC-68-45 302-5CSQS SNS6BNC RFB-1707-Q UPL20-41

C5822 CPMC-68-45 302-5CSQS SNS6BNC RFB-1707-Q UPL20-41

C5886 CPMC-68-45 — SNS6BNC RFB-1707-Q 105-1153-9

C5889 CPFI-UG88-3 (TWIST ON) 302-5CSQS SNS6QSBNC — UPL20-41

C8029 CPMC-68-45 302-5CS SNS6BNC RFB-1707-Q UPL20-41

C8031 CPMC-68-36 — — RFB-1707-Q1 105-1516-9

CAMBRIDGE GEM RF INDUSTRIES TROMPETER

CATALOG NUMBER BNC CRIMP PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC CRIMP PLUG

RG 11/UC1160 CPMC-88-26 305-26 RFB-1707-R1 UPL20-6A

C3528 CPMC-88-27 — — UPL20-6A

C3529 CPMC-88-28 — — UPL20-6A

C5011 CPMC-88-29 — RFB-1707-R UPL20-6A

C5025 CPMC-88-30 — RFB-1707-R UPL20-6A

C5029 CPMC-88-30 — RFB-1707-R UPL20-6A

C5034 CPMC-88-32 — RFB-1707-R UPL20-6A

C5039 CPMC-88-33 — RFB-1707-R UPL20-6A

C5043 CPMC-88-35 — RFB-1707-R UPL20-6A

C5044 CPMC-88-36 — RFB-1707-R UPL20-6A

AMP CAMBRIDGE GEM KINGS ELECTRONICS RF INDUSTRIES TROMPETERCATALOG NUMBER BNC PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC PLUG BNC CRIMP PLUG

RG 8/UC1108 — CPMC-88-17 305-17 — RFB-1107-1X PL20-52

C1154 2-225295-1 — — KC-59-577 MO6 RFB-1101-1EN PL20-6A

C1180 — — — KC-59-642 MO6 RFB-1101-1EN N/A

C1197 — — — RFB-1101-1SI PL20-6A

C1198 — — — RFB-1101-1SI PL20-6A

TROMPETERCATALOG NUMBER BNC CRIMP PLUG

RG 7/UC5851 PL20-48

C5853 105-1677-1

C5856 PL20-48

C5857 PL20-48

AMP www.tycoelectronics.comCambridge www.cambridgeconnectors.comGEM www.gemelec.comIdeal www.idealindustries.comKings Electronics www.kingselectronics.comRF Industries www.rfindustries.comTrompeter www.trompeter.com

192

Electronics Technical Information

Coax Connector Cross Reference

Page 204: Cross-Reference & Online Spec Sheets - Datasheet Archive

BNC TYPE CONNECTORSAMP CAMBRIDGE GEM IDEAL KINGS ELECTRONICS RF INDUSTRIES TROMPETER

CATALOG NUMBER BNC PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC CRIMP PLUG

RG 58/UC1117 22709-5 CPMC-88-1 305-1 IA-3620 755-115-5 RFB-1106-2 PL20-1

C1155 22709-5 CPMC-88-1 305-1 IA-3620 755-115-5 RFB-1106-2 PL20-1

C1166 22709-5 CPMC-88-1 305-1 IA-3620 755-115-5 RFB-1106-2 PL20-1

C1178 22709-5 CPMC-88-1 305-1 IA-3620 755-115-5 RFB-1106-2 PL20-1

C1188 22709-5 CPMC-88-1 305-1 IA-3620 – RFB-1106-2 PL20-1

C3519 6-22709-8 CPMC-88-11 305-11 – – RFB-1707-7 PL20-4

C3579 6-22709-8 CPMC-88-11 305-11 IA-3623 – RFB-1707-7 PL20-4

C5779 6-22709-8 CPMC-88-1 305-1 – – – 105-1598-1

AMP CAMBRIDGE GEM KINGS ELECTRONICS LRC RF INDUSTRIES TROMPETER

CATALOG NUMBER BNC PLUG BNC CRIMP PLUGBNC COMPRESSION

PLUG BNC CRIMP PLUG SNAP-N-SEAL BNC BNC CRIMP PLUG BNC CRIMP PLUGRG 59/U

C1102 – CPMC-78-2 307-2 (Crimp) – SNS59BNC RFB-1707-D1 UPL20-2

C1103 – CPMC-78-2 307-2CS – – RFB-1707-D1 UPL20-2

C1104 – CPMC-78-2 307-2 (Crimp) – SNS59BNC RFB-1707-D UPL20-2

C1106 – CPMC-78-2 307-2 (Crimp) – SNS59BNC RFB-1707-D UPL20-2

C1110 – CPMC-78-2 307-2 (Crimp) – SNS59BNC RFB-1707-D UPL20-2

C1112 – CPMC-78-2 307-2 (Crimp) – SNS59BNC RFB-1707-D UPL20-2

C1135 – CPMC-78-2 307-2 (Crimp) – SNS59BNC RFB-1707-D UPL20-2

C1142 – CPMC-68-35 307-2CS – SNS59BNC RFB-1707-W UPL20-2A

C1158 – CPMC-78-18 307-18 (Crimp) – – – UPL20-22

C3500 – CPMC-68-35 302-10CS – – – 105-1287-9

C3526 – CPMC-68-50 – – – – 105-1184-9

C3527 – CPMC-68-35 – – – – UPL20-53

C5770 – CPMC-68-35 302-2CS – – RFB-1707-W UPL20-2A

C5780 – CPMC-68-35 302-2CS – SNS59BNC RFB-1707-W UPL20-2A

C5784 – CP-88-4 (TWIST ON) – – – – 105-1558-9

C5830 – CPMC-78-2 307-2 (Crimp) – SNS59BNC RFB-1707-D1 UPL20-2

C8025 – CPMC-78-2 302-10CS – – RFB-1707-D UPL20-2

C8027 – CPMC-78-2 302-10CS – – – UPL20-2

C8028 – CPMC-78-2 307-2 (Crimp) – SNS59BNC – UPL20-2

C8030 – CPMC-68-10 – – – RFB-1707-D3 105-1287-9

AMP CAMBRIDGE GEM KINGS ELECTRONICS TROMPETER

CATALOG NUMBER BNC PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC CRIMP PLUG

RG 62/UC1162 22709-7 CPMC-78-2 307-2 755-155-5 UPL20-2

C1164 22709-7 CPMC-78-2 307-2 755-155-5 UPL20-2

C3520 4-22709-9 CPMC-68-2 – – 105-1287-1

AMP CAMBRIDGE GEM KINGS ELECTRONICS RF INDUSTRIES TROMPETER

CATALOG NUMBER BNC PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC CRIMP PLUG

RG 174/UC1156 1-22709-6 CPMC-88-19 305-19 KC-59-557 M06 RFB-1106-5 PL20-5

AMP CAMBRIDGE GEM RF INDUSTRIES TROMPETER

CATALOG NUMBER BNC PLUG BNC CRIMP PLUG BNC CRIMP PLUG BNC CLAMP PLUG BNC CLAMP PLUG

RG 213 /UC1176A 2-225395-1 CPMC-88-26 305-26 RFB-1101-1SI PL20-6A

AMP www.tycoelectronics.comCambridge www.cambridgeconnectors.comGEM www.gemelec.comIdeal www.idealindustries.comKings Electronics www.kingselectronics.comRF Industries www.rfindustries.comTrompeter www.trompeter.com

193

Technical Information Electronics

Coax Connector Cross Reference

Page 205: Cross-Reference & Online Spec Sheets - Datasheet Archive

F-TYPE CONNECTORS

CAMBRIDGE GEM GILBERT IDEAL INDUSTRIES

CATALOG NUMBER F-TYPE CRIMP F-TYPE COMPRESSION F-TYPE CRIMP F-TYPE COMPRESSION F-TYPE

RG 6/UC3521 CPF-56-ALM 0406-4 (Crimp) GF-6-AHS/USA Contact Gilbert –

C3523 CPF-56-ALM 0406-610CS NS-8101-15 Contact Gilbert –

C3524 CPF-56-ALM 0406-610CS Contact Gilbert Contact Gilbert –

C3525 CPF-56-ALM 0406-4 (Crimp) Contact Gilbert Contact Gilbert –

C5760 CPF-56-ALM 0406-4 (Crimp) GF-6-AHS/USA GF-UR-6 –

C5761 CPF-56-ALM 0406-6CSQS GF-6-AHS/USA GF-UR-6 85-037

C5775 CPF-56-ALM 0406-6CSQS GF-6-AHS/USA GF-UR-6 85-037

C5776 CPF-56-ALM 0406-4 (Crimp) GF-6-AHS/USA GF-UR-6 85-037

C5777 CPF-56-ALM 0406-4 (Crimp) GF-6-AHS/USA GF-UR-6 85-037

C5778 CPF-56-ALM 0406-4 (Crimp) GF-6-AHS/USA GF-UR-6 –

C5785 CPF-56-ALM 0406-6CSQS GF-6-AHS/USA GF-UR-6 85-057

C5802 CPF-56-ALM 0406-4 (Crimp) GF-6-AHS/USA GF-UR-6 85-037

C5804 CPF-56-ALMWP – GF-6-AHS/USA GF-UR-6 85-037

C5814 CPF-56-ALM 0406-6CSQS GF-6-AHS/USA GF-UR-6 85-037

C5822 CPF-56-ALM 0406-6CSQS GF-6-AHS/USA GF-UR-6 85-037

C5886 CPF-56-ALM 0406-4 (Crimp) GF-6-AHS/USA GF-UR-6 85-037

C5889 CPF-56-ALS 0406-6CSQS GF-6-AHS/USA GF-UR-6 85-057

C8029 CPF-56-ALM 0406-6CS Contact Gilbert Contact Gilbert –

C8031 CPF-56-ALM 0406-4 (Crimp) Contact Gilbert Contact Gilbert –

LRC PPC TROMPETER

CATALOG NUMBER F-TYPE CRIMP SNAP-N-SEALU SERIESU-INDOOR

SU-OUTDOOR

UV SERIESUV-INDOOR

SUV INDOOR/OUTDOOR

EXINDOOR/OUTDOOR F-TYPE CRIMP

RG 6/U (cont.)

C3521 – – CFS 6 PL – EX6P or EX6XLP –

C3523 – – CFS 6 PL – EX6P or EX6XLP –

C3524 – – CFS 6 PL – EX6P or EX6XLP –

C3525 – – – – – –

C5760 – – CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP –

C5761 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020

C5774 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020

C5775 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP –

C5776 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020

C5777 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020

C5778 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020

C5785 AMF6 SNS6QS CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP –

C5802 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020

C5804 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020

C5810 – – – – – PL130SC-017

C5812 – – CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP –

C5814 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020

C5822 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020

C5824 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020

C5826 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020

C5886 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP –

C5888 AMF6 SNS6 CFS 6 U (SU) CFS 6 UV (SUV) EX6 or EX6XLP PL130SC-020

C5889 AMF6 SNS6QS – – – –

C5890 AMF6 SNS6 – – – PL130SC-020

C8029 AMF6 SNS6 – – – PL130SC-020

C8031 – – – – – –

AMP www.tycoelectronics.comCambridge www.cambridgeconnectors.comGEM www.gemelec.comIdeal www.idealindustries.comKings Electronics www.kingselectronics.comRF Industries www.rfindustries.comTrompeter www.trompeter.com

194

Electronics Technical Information

Coax Connector Cross Reference

Page 206: Cross-Reference & Online Spec Sheets - Datasheet Archive

F-TYPE CONNECTORS

GILBERT LRC PPC

CATALOG NUMBER F-TYPE CRIMP F-TYPECOMPRESSION F-TYPE CRIMP SNAP-N-SEAL

U SERIESU-INDOOR

SU-OUTDOOR

PNU SERIESPNU-INDOOR

PNSU INDOOR/OUTDOOR

EXINDOOR/OUTDOOR

RG 7/UC5851 GAF-236/051-AHS/368 GAF-UST-7 AMF7 SNS7B CFS 7 U (SU) CFS 7 PNU (PNSU) EX 7

C5853 GAF-236/051-AHS/368 GAF-UST-7 – – CFS 7 U (SU) CFS 7 PNU (PNSU) EX 7

C5856 GAF-236/051-AHS/368 GAF-UST-7 – – CFS 7 U (SU) CFS 7 PNU (PNSU) EX 7

C5857 GAF-236/051-AHS/398 GAF-UST-7Q – – CFS 7 U (SU) CFS 7 PNU (PNSU) –

CAMBRIDGE GEM GILBERT IDEAL INDUSTRIES LRC

CATALOG NUMBER F-TYPE CRIMP F-TYPE COMPRESSION F-TYPE CRIMP F-TYPE COMPRESSION F-TYPE F-TYPE CRIMP SNAP-N-SEAL

RG 59/UC1102 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59

C1103 CPF-59-ALM 0459-2CS GF-59-AHS/USA GF-UR-59 85-036 – –

C1104 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59

C1106 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59

C1110 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59

C1112 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59

C1135 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59

C1142 CPF-59-ALM 0459-2CS GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59

C1158 – – GF-1097-17 Contact Gilbert – – –

C3500 – 0459-10CS Contact Gilbert Contact Gilbert – – –

C3526 – – Contact Gilbert Contact Gilbert – – –

C3527 CPF-59-ALM 0459-2M (Crimp) Contact Gilbert Contact Gilbert – – –

C5770 CPF-59-ALM 0459-2CS Contact Gilbert Contact Gilbert 85-036 – –

C5780 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59

C5784 – – GF-59-AHS/357 Contact Gilbert 85-059 – SNS59QS

C5830 CPF-59-ALM 0459-2M (Crimp) GF-59-AHS/USA GF-UR-59 85-036 AMF59 SNS59

C8025 CPF-59-ALM 0459-10CS Contact Gilbert Contact Gilbert – – –

C8027 CPF-59-ALM 0459-10CS Contact Gilbert Contact Gilbert – – –

C8028 CPF-59-ALM 0459-2M (Crimp) Contact Gilbert Contact Gilbert – AMF59 SNS59

C8030 CPF-59-ALM 0459-2M (Crimp) Contact Gilbert Contact Gilbert – – –

CAMBRIDGE GILBERT LRC PPC

CATALOG NUMBER

F-TYPECRIMP

F-TYPECRIMP

F-TYPE COMPRESSION

F-TYPECRIMP SNAP-N-SEAL

U SERIESU-INDOOR

SU-OUTDOOR

UV SERIESUV-INDOOR

SUB INDOOR/OUTDOOR

EXINDOOR/OUTDOOR

RG 11/UC1160 CPF-11-ALM Contact Gilbert Contact Gilbert – – – – –

C3528 CPF-11-ALM Contact Gilbert Contact Gilbert – – – – –

C3529 CPF-11-ALM Contact Gilbert Contact Gilbert – – – – –

C5011 CPF-11-ALM GF-11-AHS/460 GAF-UST-11 AMF11 SNS11AS CFS 11 U (SU) CFS 11 PNU (PNSU) EX 11

C5025 CPF-11-ALM Contact Gilbert Contact Gilbert – – CFS 11 U (SU) CFS 11 PNU (PNSU) EX 11

C5029 CPF-11-ALM GF-11-AHS/460 GAF-UST-11 AMF11 SNS11AS CFS 11 U (SU) CFS 11 PNU (PNSU) EX 11

C5034 CPF-11-ALM GF-11-AHS/460 GAF-UST-11 AMF11 SNS11AS CFS 11 U (SU) CFS 11 PNU (PNSU) EX 11

C5039 CPF-11-ALM GF-11-AHS/460 GAF-UST-11 AMF11 SNS11AS CFS 11 U (SU) CFS 11 PNU (PNSU) EX 11

C5043 CPF-11-ALM GF-11-AHS/460 GAF-UST-11 AMF11 SNS11AS CFS 11 U (SU) CFS 11 PNU (PNSU) EX 11

C5044 – GF-11-AHS/480 GAF-UST-11Q AMF11 SNS11AS CFS 11 U (SU) CFS 11 PNU (PNSU) EX 11

195

Technical Information Electronics

Coax Connector Cross Reference

AMP www.tycoelectronics.comCambridge www.cambridgeconnectors.comGEM www.gemelec.comIdeal www.idealindustries.comKings Electronics www.kingselectronics.comRF Industries www.rfindustries.comTrompeter www.trompeter.com

Page 207: Cross-Reference & Online Spec Sheets - Datasheet Archive

F-TYPE CONNECTORS

PPC TROMPETER

CATALOG NUMBERU SERIESU-INDOOR

SU-OUTDOOR

UV SERIESUV-INDOOR

SUV INDOOR/OUTDOOR

EXINDOOR/OUTDDOR F-TYPE CRIMP

RG 59/U (cont.)C1102 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-014

C1103 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013

C1104 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013

C1106 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013

C1110 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013

C1112 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013

C1135 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013

C1142 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-023

C1158 – – – PL130SC-008

C3500 – – – –

C3526 – – – –

C3527 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-023

C5770 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-022

C5780 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-023

C5784 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL –

C5830 CFS 59 U (SU) CFS 59 UV (SUV) EX59 or EX59XL PL130SC-013A

C8025 – – – PL130SC-013

C8027 – – – PL130SC-013

C8028 – – – PL130SC-013A

C8030 – – – –

TROMPETER

CATALOG NUMBER F-TYPE CRIMP

RG 62/UC1162 PL130SC-013

C1164 PL130SC-013

C3520 –

TROMPETER

CATALOG NUMBER F-TYPE CRIMP

RG 174/UC1156 PL130SC-004

196

Electronics Technical Information

Coax Connector Cross Reference

AMP www.tycoelectronics.comCambridge www.cambridgeconnectors.comGEM www.gemelec.comIdeal www.idealindustries.comKings Electronics www.kingselectronics.comRF Industries www.rfindustries.comTrompeter www.trompeter.com

Page 208: Cross-Reference & Online Spec Sheets - Datasheet Archive

CAMBRIDGE TROMPETER

CATALOG NUMBER N-TYPE CRIMP PLUG N-TYPE CRIMP PLUG

RG 11/UC1160 CPN-8 UPL95-6A

C3528 CPN-8 UPL95-6A

C3529 CPN-8 UPL95-6A

C5011 CPN-8 UPL95-6A

C5025 CPN-68-8 UPL95-6A

C5029 CPN-8 UPL95-6A

C5034 CPN-8 UPL95-6A

C5039 CPN-8 UPL95-6A

C5043 CPN-8 UPL95-6A

C5044 CPN-68-8 UPL95-6A

AMP CAMBRIDGE KINGS ELECTRONICS LRC RF INDUSTRIES TROMPETER

CATALOG NUMBER N-TYPE PLUG N-TYPE CRIMP PLUG N-TYPE CRIMP PLUG N-TYPE PLUG N-TYPE CRIMP PLUG N-TYPE PLUG

RG 8/UC1108 — — — — RFN-1007-2SX —

C1154225661-2 (Mil)

CPN-68-8 KN-59-176 —RFN-1006-3E

PL95-6A415232-6 RFN-1006-3E

C1180 — CPN-8/110 1205-4-9 NM8HB10 RFN-1006-3I —

C11981-225661-6 (Mil)

CPN-68-8 1205-4-9 — RFN-1006-3I PL95-6A414160-4

TROMPETER

CATALOG NUMBER N-TYPE CRIMP PLUG

RG 6/UC3521 —

C3523 —

C3524 —

C3525 —

C5760 —

C5761 UPL95-34

C5775 —

C5776 —

C5777 —

C5778 —

C5785 —

C5802 —

C5804 —

C5814 —

C5822 UPL95-41

C5886 —

C5889 UPL95-41

C8029 UPL95-41

C8031 —

TROMPETER

CATALOG NUMBER N-TYPE CRIMP PLUG

RG 7/UC5851 PL95-48

C5853 N/A

C5856 PL95-48

C5857 PL95-48

N-TYPE CONNECTORS

197

Technical Information Electronics

Coax Connector Cross Reference

AMP www.tycoelectronics.comCambridge www.cambridgeconnectors.comGEM www.gemelec.comIdeal www.idealindustries.comKings Electronics www.kingselectronics.comRF Industries www.rfindustries.comTrompeter www.trompeter.com

Page 209: Cross-Reference & Online Spec Sheets - Datasheet Archive

AMP CAMBRIDGE GEM RF INDUSTRIES TROMPETER

CATALOG NUMBER N-TYPE PLUG N-TYPE CRIMP PLUG N-TYPE CRIMP PLUG N-TYPE CRIMP PLUG N-TYPE CRIMP PLUG

RG 59/UC1102 — — — RFN-1907-2S UPL95-2

C1103 — CPN-2 400-2 RFN-1907-2S UPL95-2

C1104 — CPN-2 400-2 RFN-1907-2S UPL95-2

C1106 — CPN-2 400-2 RFN-1907-2S UPL95-2

C1110 — CPN-2 400-2 RFN-1907-2S UPL95-2

C1112 — CPN-2 400-2 RFN-1907-2S UPL95-2

C1135 — CPN-2 400-2 RFN-1907-2S UPL95-2

C1142 — — — — UPL95-2A

C1158 — — — — UPL95-22

C3500 — — — — —

C3526 — — — — —

C3527 — — — — —

C5770 — — — — UPL95-2A

C5780 — — — — UPL95-2A

C5784 — — — — —

C5830 — — — RFN-1907-2S UPL95-2

C8025 — CPN-2 400-2 — UPL95-2

C8027 — CPN-2 400-2 — UPL95-2

C8028 — — — — UPL95-2

C8030 — — — — —

N-TYPE CONNECTORS

AMP CAMBRIDGE KINGS ELECTRONICS RF INDUSTRIES TROMPETER

CATALOG NUMBER N-TYPE PLUG N-TYPE CRIMP PLUG N-TYPE CRIMP PLUG N-TYPE CRIMP PLUG N-TYPE CRIMP PLUG

RG 58/U

C11171-225661-2 (Mil)

CPN-68-1 1205-19-5 RFN-1005-3C PL95-1415232-2

C11551-225661-2 (Mil)

CPN-68-1 1205-19-5 RFN-1005-3C PL95-1415232-2

C11661-225661-2 (Mil)

CPN-68-1 1205-19-5 RFN-1005-3C PL95-1415232-2

C11781-225661-2 (Mil)

CPN-68-1 1205-19-5 RFN-1005-3C PL95-1415232-2

C11881-225661-2 (Mil)

CPN-68-1 — RFN-1005-3C PL95-1415232-2

C3519 — CPN-1 — — PL95-4

C3579 — CPN-1 — — PL95-4

C5779 — CPN-1 — — —

198

Electronics Technical Information

Coax Connector Cross Reference

AMP www.tycoelectronics.comCambridge www.cambridgeconnectors.comGEM www.gemelec.comIdeal www.idealindustries.comKings Electronics www.kingselectronics.comRF Industries www.rfindustries.comTrompeter www.trompeter.com

Page 210: Cross-Reference & Online Spec Sheets - Datasheet Archive

N-TYPE CONNECTORS

AMP CAMBRIDGE GEM TROMPETER

CATALOG NUMBER N-TYPE PLUG N-TYPE CRIMP PLUG N-TYPE CRIMP PLUG N-TYPE PLUG

RG 62/UC1162 — CPN-2 400-2 UPL95-2

C1164 — CPN-2 400-2 UPL95-2

C3520 — — — —

AMP CAMBRIDGE KINGS ELECTRONICS RF INDUSTRIES TROMPETER

CATALOG NUMBER N-TYPE PLUG N-TYPE CRIMP PLUG N-TYPE CRIMP PLUG N-TYPE PLUG N-TYPE PLUG

RG 213/U

C1176A1-227086-0 (MIL)

CPN-68-8 KN-59-202 RFN-1006-3I PL95-6A415232-6

AMP RF INDUSTRIES TROMPETER

CATALOG NUMBER N-TYPE PLUG N-TYPE PLUG N-TYPE PLUG

RG 174/UC1156 — RFN-1005-B-03 PL95-5

199

Technical Information Electronics

Coax Connector Cross Reference

ONE-PIECE CONNECTORS

GENERAL CABLEWHITE SANDS ENGINEERING

ONE-PIECE CONNECTOR

RG 6/U395025 SLC59

SLCUHEC2

395011 SLC6/SLC6O

SLC6Q/SLC6QO

395025 BNCFP59

395025 BNCFPSLC59

BNCFPSLCHEC

395011 BNCFP6

395011 BNCFPSLC6/BNCFPSLC6G

BNCFPSLC6Q/BNCFPSLC6QG

395025 RCAFP59

395025 RCAFPSLC59/RCAFPSLC59G

395011 RCAFPSLC6/RCAFPSLC6G

RCAFPSLC6QG

AMP www.tycoelectronics.comCambridge www.cambridgeconnectors.comGEM www.gemelec.comIdeal www.idealindustries.comKings Electronics www.kingselectronics.comRF Industries www.rfindustries.comTrompeter www.trompeter.comWhite Sands www.whitesandsengineering.com

Page 211: Cross-Reference & Online Spec Sheets - Datasheet Archive

200

Electronics Technical Information

COPPER CONDUCTOR DATAThe conductors used by General Cable meet the applicable requirements of ASTM specifications B-3, B-33, B-172, B-173, B-174 and B-286 and Federal Specification QQ-W-343.

The following data covers the more commonly used conductor constructions in the electrical and electronics industry. Special constructions, not shown, are available or can be designed to meet specific requirements. It is suggested that the General Cable Product Engineering Department be contacted before a specification is finalized.

AWG STRANDINGTYPE

STRANDING(1)

DIAMETER(4) AREA WEIGHT

D.C. RESISTANCE 20°C(2)

BREAK STR.LBS

TIN COATING(3) BARE OF SILVER COATING

in mm circ. mils sq. mm lbs/Mft kg/km Ω/Mft Ω/km Ω/Mft Ω/km

32 7/40 Co or Bu .0096 .254 100 .051 .21 .31 176.00 577.00 164.00 538.00 1.986

30 Solid 7/38

– Bu

.010

.012 .254 .305

100 112

.051 .057

.30 .35

.45 .52

113.00 106.00

371.00 348.00

104.00 92.60

340.00 303.00

3.157

28 Solid 7/36

– Co

.01264

.015 .321 .381

159 175

.081 .089

.48 .55

.72 .82

70.80 67.50

232.00 221.00

65.30 59.30

214.00 194.00

5.020

27 Solid 7/35

– Co or Bu

.0142

.017 .361 .432

202 220

.102 .111

.61 .69

.91 1.04

55.60 53.80

182.00 176.00

51.40–

169.00–

6.331

26Solid 7/34 10/36 19/38

– Co or Bu Bu Bu or Co

.016

.019

.0193

.021

.404 .483 .490 .533

253 278 250 304

.128 .141 .127 .154

.77 .87 .78 .97

1.14 1.29 1.15 1.44

44.50 42.50 47.30 38.90

146.00 139.00 155.00 128.00

41.00 37.30 40.40 34.10

135.00 122.00 133.00 112.00

7.983

24Solid 7/32 16/36 19/36

– Co or Bu Bu Co or Bu

.0201

.024

.024

.025

.511 .610 .610 .635

404 448 400 475

.205 .227 .201 .241

1.22 1.38 1.25 1.48

1.82 2.05 1.64 2.20

27.20 25.70 29.50 24.90

89.20 84.20 96.80 81.70

25.70 23.10 27.50 21.80

84.20 75.90 90.20 71.60

12.690

22Solid 7/30 19/34

– Co or Bu Bu or Eq

.025

.030

.0315

.643 .762 .800

643 700 754

.324 .355 .382

1.94 2.19 2.35

2.89 3.26 3.50

16.70 16.60 15.50

54.80 54.40 50.80

16.20 14.80 13.80

53.20 48.60 45.10

19.430

20

Solid 7/28 10/30 19/32 26/34

– Co or Bu Bu Co, Bu or Eq Bu

.032

.038

.037

.040

.039

.813 .965 .940 1.02 .940

1,020

1,111 1,000 1,216

.519 .562 .507 .616 .523

3.10 3.49 3.14 3.84 3.28

4.61 5.19 4.67 5.71 4.88

10.50 10.30 11.40 9.48 11.30

34.40 33.80 37.40 31.10 37.10

10.10 9.33 10.40 8.53

33.20 30.60 34.00 28.00

30.890

19 Solid – .0359 .912 1,032 .653 3.90 5.80 – – 8.05 26.40 38.950

18

Solid 7/26 16/30 19/30 41/34

– Co or Bu Bu Co, Bu or Eq Bu

.0403

.048

.0475

.050

.049

1.024 1.22 1.207 1.27 1.244

1,290 1,620 1,770 1,600 1,900

.823 .897 .810 .963 .824

4.92 5.55 5.01 5.95 5.09

7.32 8.26 7.45 8.85 7.08

6.77 6.45 7.15 6.10 7.08

22.20 21.20 23.40 20.00 23.20

6.39 5.55 6.48 5.46 6.60

21.00 19.20 21.30 17.90 21.60

49.120

16

Solid 19/294 19/.0117 26/30 65/34

– Bu or Eq Bu Bu Bu

.0508

.057

.0585

.0606

.060

1.29 1.45 1.50 1.54 1.52

1,627 2,580 2,426 2,601 2,600

1.31 1.23 1.32 1.32 1.31

7.81 7.52 8.02 8.15 8.20

11.60 11.20 11.90 12.10 11.90

4.47 4.82 4.39 4.39 4.47

14.70 15.80 14.40 14.40 14.70

4.16 4.27 4.13 3.99 4.16

13.60 14.00 13.50 13.10 13.60

78.100

14

Solid 7/.0242 19/274 19/.0147 41/30

– Co Co, Eq or Un Bu Bu

.0641

.073

.071

.074

.077

1.63 1.85 1.80 1.88 1.96

2,581 4,110 4,100 3,831 4,106

2.08 2.08 1.94 2.08 2.08

12.4 12.7 12.1 12.7 12.9

18.50 18.90 18.00 18.90 19.20

2.68–

3.05 2.73 2.81

8.79–

10.00–

9.22

2.52 2.61 2.71 2.61 2.53

8.28 8.56 8.88 8.56 8.30

124.200

12

Solid 7/.0305 19/254 19/.0185 65/30

– Bu Co, Eq or Un Cu Bu

.0808

.092

.0905

.0925

.094

2.05 2.34 2.299 2.35 2.388

4,100 6,530 6,512 6,088 6,503

3.31 3.30 3.08 3.30 3.29

19.8 20.2 19.4 20.2 20.8

29.50 30.10 28.90 30.10 31.10

1.69–

1.87–

1.82

5.54–

6.13–

5.97

1.59 1.64 1.70 1.64 1.64

5.21 5.38 5.59 5.25 5.25

197.500

10

Solid 7/.0385 19/.0234 37/.0169 105/30

– Co Bu Co Bu

.1019

.116

.117

.112

.126

2.588 2.95 2.97 2.84 3.20

6,500 10,380 10,376 10,404

9,361

5.26 5.25 5.27 4.74 5.32

31.4 32.0 32.0 29.2 33.8

46.80 47.60 47.60 43.40 49.20

– – – –

1.10

– – – –

3.61

1.00 1.00 .98 1.25 .99

3.28 3.28 3.21 4.10 3.24

314.500

87/.0486 19/.0295 133/29 168/30

Bu Bu or Eq Ro 19 x 7/29 Ro 7 x 24/30

.146

.144

.169

.174

3.71 3.66 4.293 4.42

10,500 16,534 16,535 16,983

8.38 8.38 8.61 8.51

50.1 50.0 54.0 53.4

74.50 74.40 80.40 79.00

––

.71 .70

– –

2.33 2.30

.65 .65

– –

2.13 2.13

– –

619/.0374 133/27 266/30

Bu Ro 19 x 7/27 Ro 7 x 38/30

.188

.213

.222

4.775 5.41 5.64

16,800 26,576 26,818

13.33 13.60 13.49

81.1 84.1 83.2

121.00 125.00 124.00

– .43 .44

– 1.41 1.44

.40– –

1.30– –

4 133/25 420/30

Ro 19 x 7/25 Ro 7 x 60/30

.257

.270 6.53 6.850

26,600 42,615

21.61 21.29

135.0 140.0

201.00 208.00

.29 .28

.95 .92

– –

– –

2 665/30 Ro 19 x 35/30 .338 8.59 42,000 33.72 213.0 317.00 .18 .59 – –

(1) Bu - Bunched; Co - Concentric; Eq - Equilay; Ro - Rope; Un - Unilay(2) Typical DC resistance values for uninsulated wires. Multiply by 1.04 for typical values after insulation(3) Values are for tinned, heavy tinned, prefused, overcoated or topcoated conductors(4) Does not meet UL conductor stranding requirements

AWG Conductor Chart

Page 212: Cross-Reference & Online Spec Sheets - Datasheet Archive

201

Technical Information Electronics

% Coverage Factor for Common Coverage:

D dP

e

C

U

F % Coverage0.368 0.409 0.453 0.500 0.553 0.617

60 65 70 75 80 85

where: D = diameter under shield, inches d = diameter of center conductor, inches C = number of carriers e = diameter of end P = pick (measured in picks per linear inch) U = braid angle, degrees W = weight of shield, lbs/M ft n = number of ends in one carrier l = weight of one end in lbs/M ft M = D + build-up of braid on one shield wall, inches Rdc = dc resistance of the braid shield, /M ft rdc = dc resistance of one strand (end) of shield, /M ft % C = percent braid coverage F = % coverage factor

BRAID PICKS PER INCH:

P = (C) (tan U) , PICKS/INCH 2 (M)

BRAID SHIELD DC RESISTANCE:Rdc = cos rdc , /kft (n) (C) (cos U)

% Coverage: %C = (2F - F2) x-100

BRAID ANGLE:

U= tan-1 2 (D-+-2e) P , DEGREES

C

BRAID SHIELD WEIGHT:

W = (n) (C) (I) , LBS/M FT cos U

Cable Design Equations—Braid Shield

Page 213: Cross-Reference & Online Spec Sheets - Datasheet Archive

202

Electronics Technical Information

COAXIAL CABLE CAPACITANCE:

C = 7.36ε , pF/ft LOG ( D ) fd

COAXIAL CABLE VELOCITY OF PROPAGATION:

Vp = 100 , % ε1/2

COAXIAL CABLE INDUCTANCE:

L = 0.140 LOG ( D ), µH/ft fd

COAXIAL CABLE TIME DELAY:

td = 1.016 ε1/2, nsec/ft

COAXIAL CABLE CUTOFF FREQUENCY:

fco = 7.50 , GHz ε

1/2 (D + fd)

where: C = capacitance, pF/ft ε = insulation dielectric constant (see table below) D = diameter under the shield, inches d = diameter of the center conductor, inches L = inductance, µH/ft f = strand factor (see Table II, page 194)

Zo = characteristic impedance, Vp = velocity of propagation, % td = time delay, nsec/ft fco = cutoff frequency, GHz

COAXIAL CABLE IMPEDANCE:

Zo = 138 LOG ( D ), ε

1/2 fd

MATERIAL ε POWER FACTOR, PF

FEP Teflon® (Cellular)FEP Teflon® (Solid)PE (Cellular)PE (Solid)PE (Semi-Solid)

1.40 2.10 1.56 2.26 1.29

0.00020.00030.00030.00030.0003

Cable Design Equations—Coaxial Cable

Page 214: Cross-Reference & Online Spec Sheets - Datasheet Archive

203

Technical Information Electronics

MATERIAL

TABLE I

where: C = mutual capacitance, pF/ft ε = insulation dielectric constant (see Table I) f = stranding factor (see Table II) d = diameter of the conductor, inches D = diameter over the insulation, inches Zo = characteristic impedance

DIELECTRIC CONSTANTS & Vp OF INSULATIONSε Vp, %

ECTFE (Halar™)FEPPFA Teflon®

PVCPVC (Semi-rigid)PVDF (Kynar™, SOLEF™)PolyethylenePolypropylenePolyurethaneRubber, butylRubber, naturalRubber, SBRRubber, siliconeTFE Teflon®

TPETeflon®

Tefzel®

IMPEDANCE (UNSHIELDED TWISTED PAIR):

Zo = 1016 1/2 , C

TABLE IINO. OF STRANDS ƒ

1 7 19 37 61 91

1.000 0.939 0.970 0.980 0.985 0.988

CAPACITANCE (UNSHIELDED TWISTED PAIR):

C = 2.2 ε , pF/ft LOG 1.3 (D) (f) (d)

CAPACITANCE (SHIELDED TWISTED PAIR):

C = 3.7 ε , pF/ft LOG 1.2 (D) (f) (d)

C = 2.9 ε , pF/ft LOG 1.5 (D) (f) (d)

CAPACITANCE (OVERALL SHIELDED & CABLED): IMPEDANCE (OVERALL SHIELDED & CABLED):

Zo = 347 LOG 1.5 (D) , ε1/2 (f) (d)

Zo = 276 LOG 1.2 (D) , ε1/2 (f) (d)

IMPEDANCE (SHIELDED TWISTED PAIR):

2.60 2.15 2.15 5.00 3.60 7.70 2.29 2.25 6.50 4.0 5.0 4.0 3.1 2.1 5.0 2.10 2.6

6368684553366667395045505769456962

Cable Design Equations—Balanced Pair

Page 215: Cross-Reference & Online Spec Sheets - Datasheet Archive

204

Electronics Technical Information

PREFIX SYMBOL tera giga mega kilo hecto deca deci centi milli micro nano pico femto atto

1012

109

106

103

102

101

10-1

10-2

10-3

10-6

10-9

10-12

10-15

10-18

1,000,000,000,0001,000,000,0001,000,0001,000100100.10.010.0010.0000010.0000000010.0000000000010.0000000000000010.000000000000000001

MULTIPLYING FACTORCONVENTIONAL

T G M k h da d c m µ n p f

a

SCIENTIFIC

Engineering Prefixes

Page 216: Cross-Reference & Online Spec Sheets - Datasheet Archive

205

Technical Information Electronics

Abrasion Resistance: Resistance to surface wear.

AC Alternating Current (a.c.): Current in which the charge-flow periodically reverses and is represented by: I = l8cos (2-f +-f) where, I is the current, l8 is the amplitude, f the frequency, f the phase angle.

Accelerated Aging: A test that attempts to duplicate long-time environmental aging in comparatively short time spans.

Accelerator: A chemical additive which hastens a chemical reaction under specific conditions.

Accordion: (1) A retractile cable with a series of equally-spaced transverse folds. (2) A connec-tor contact with a “Z” shaped flat spring to permit high deflection without overstress.

Adapter: A device that enables any or all of the following 1) different sizes or types of plugs to mate with one another or to fit into a telecommunications outlet/connector; 2) the rearrangement of leads; 3) large cables with numerous wires to fan out into smaller groups of wires, 4) interconnection between cables.

Adhesive Bonded: Cables bonded by adding an adhesive coating to the surface of the cable components, then joining and curing the adhesive to form a cable. See Bonded Cable.

Administration: The method for labeling, identification, documentation and usage needed to implement moves, additions and changes of the telecommunications infrastructure.

Admittance: The measure of the ease with which an alternating current flows in a circuit. The reciprocal of impedance.

Aerial Cable: A cable suspended in the air on poles or other overhead structure.

Aging: The change in properties of a material with time under specific conditions.

Air Core Cable: A cable in which the interstices in the cable core are not filled with a moisture barrier.

Air-Handling Plenum: A designated area, closed or open, used for environmental air.

Air Spaced Coaxial Cable: One in which air is essentially the dielectric material. A spirally wound synthetic filament, beads or braided filaments may be used to center the conductor.

All-Rubber Cable: A cable in which all interstices between conductors are filled with rubber compound.

Alligator Clip: A mechanical device shaped like alligator jaws used as a temporary connection on the end of interconnections wire.

Alloy: A metal formed by combining two or more different metals to obtain desirable properties.

Aluminum Conductor: An aluminum wire or group of wires not suitably insulated to carry electrical current.

Aluminum-Steel Conductor: A composite conductor made up of a combination of aluminum and steel wires.

Ambient Temperature: The temperature of a medium (gas or liquid) surrounding an object.

American Wire Gauge (AWG): The standard system used for designating wire diameter. The lower the AWG number, the larger the diameter. Also called the Brown and Sharpe (B&S) wire gauges.

Ampacity: See Current Carrying Capacity.

Ampere: The unit of current. One ampere is the current flowing through one ohm of resistance at one volt potential.

Analog: A signaling format that uses continuous physical variables such as voltage amplitude or frequency variations to transmit information.

Anneal: Relief of mechanical stress through heat and gradual cooling. Annealing copper renders it less brittle.

Annular Conductor: A number of wires stranded in three reversed concentric layers around a core.

Annunciator: A signaling device, usually electri-cally operated, that gives an audible or visual signal (or both) when energized.

Anti-Oxidant: A substance which prevents or slows down oxidation of material exposed to air.

Appliance Wire and Cable: A classification covering insulated wire and cable for internal wiring of appliances and equipment.

Arc Resistance: The time required for an arc to establish a conductive path in a material.

Armored Cable: A cable provided with a wrap-ping of metal for mechanical protection.

Attenuation: The decrease in magnitude of the power of a signal in transmission between points. Attenuation is usually measured in decibels per unit length at a specific frequency.

Attenuation to Crosstalk Ratio (ACR): The difference between attenuation and crosstalk, measured in dB, at a given frequency. Important characteristic in networking transmission to assure that signal sent down a twisted pair is stronger at the receiving end, after being attenuated, than are any interference signals imposed on that same pair by crosstalk from other pairs, represented by NEXT.

Audio Frequency: The range of frequencies audible to the human ear. Usually 20-20,000 Hz.

Backbone: A facility (e.g. pathway, cable or conductors) between telecommunications closets or floor distribution terminals, the entrance facilities and the equipment rooms within or between buildings.

Backbone Cable or Wire: Cable or wire found in the backbone; see Backbone.

Balanced Line: A cable having two identical conductors which carry voltages opposite in polarity and equal in magnitude with respect to ground.

Balun: A device for matching an unbalanced coaxial transmission line to a balanced two-wire system.

Band Marking: A continuous circumferential band applied to a conductor at regular intervals for identification.

Banded Cable: Two or more cables banded together by stainless steel strapping.

Bandwidth: A continuous range of frequencies extending between two limiting frequencies. Also referred to as a frequency band.

Barrel-Packed: Method of coiling into a fiber drum for shipment.

Baseband: In data transmission, the use of a dedicated end-to-end connection to carry a single channel only.

Beaded Coax: Coaxial cable with a dielectric consisting of beads made of various materials.

Belt: Number of layers of insulation on a conduc-tor, or number of layers of jacket on a cable.

Belted-Type Cable: Multiple conductor cable having a layer of insulation over the assembled insulated conductors.

Bend Loss: A form of increased attenuation caused by (1) having an optical fiber curved around a restrictive radius of curvature or (2) microbends caused by minute distortions in the fiber imposed by externally induced forces.

Bend Radius: Radius of curvature that a fiber optic or metallic cable can bend without any adverse effects.

Bifilar: A winding made non-inductive by winding together (as one wire) two wires carrying current in opposite directions.

Billion Conductor Feet (BCF): A quantity derived by multiplying the number of conductors in a cable by the amount of cable. Usually used to indicate plant capacity or an annual requirement.

Bimetallic Wire: A wire formed of two different metals joined together (not alloyed). It can include wire with a steel core clad wire, or plated or coated wire.

Binder: A spirally served tape or thread used for holding assembled cable components in place awaiting subsequent manufacturing operations.

Binding Post: A device for clamping or holding electrical conductors in a rigid position.

Bit: One binary (0 or 1) digit.Blown Jacket: Outer cable covering applied by

controlled inflation of the cured jacket tube then pulling the cable through it.

Bond Strength: Amount of adhesion between bonded surfaces, e.g. in cemented ribbon cable.

Bondable Wire: An insulated wire treated to facilitate adherence to materials such as potting compounds. Also, magnet wires used in making coils when bonding the turns together is desired.

Bonded Cable: Cable consisting of pre-insulated conductors or multiconductor components laid-in parallel and bonded into a flat cable. See Solvent-Bonded; Adhesive-Bonded; Film-Bonded.

Bonded Construction: An insulation construction in which the glass braid and nylon jacket are bonded together.

Bonding: The permanent joining of metallic parts to form an electrically conductive path that will assure electrical continuity and the capacity to conduct safely any current likely to be imposed on it.

Booster: A device inserted into a line (or cable) to increase the voltage.

Boot: (1) Protective covering over a cable, wire or connector in addition to the normal jacketing or insulation. (2) A form placed around wire termination of a multiple-contact connector to contain the liquid potting compound before it hardens.

Braid: A fibrous or metallic group of filaments interwoven in cylindrical form to form a covering over one or more wires.

Braid Angle: The smaller of the two angles formed by the shielding strand and in the axis of the cable being shielded.

Braid Carrier: A spool or bobbin on a braid which holds one group of strands or filaments consisting of a specific number of ends. The carrier revolves during braiding operations.

Glossary

Page 217: Cross-Reference & Online Spec Sheets - Datasheet Archive

206

Electronics Technical Information

Braid Ends: The number of strands used to make up one carrier. The strands are wound side by side on the carrier bobbin and lie parallel in the finished braid.

Braiding Machine: Machine used to apply braids to wire and cable and to produce braided sleeving and braids for tying or lacing purposes. Braiding machines are identified by the number of carriers.

Breakdown (Puncture): A disruptive discharge through the insulation.

Breakdown Voltage: The voltage at which the insulation between two conductors breaks down.

Breakout: The point at which a conductor or group of conductors breaks out from a multiconductor cable to complete circuits at various points along the main cable.

Bridge: A device used to expand a local area network by forwarding frames between data link layers.

Bridged Tap: The multiple appearances of the same cable pair at several distribution points.

British Standard Wire Gauge: A modification of the Birmingham Wire Gauge and the legal standard of Great Britain for all wires. Also known as Standard Wire Gauge (SWG), New British Standard (NBS), English Legal Standard and Imperial Wire Guide.

Broadband: In data transmission, the use of a carrier signal, rather than direct modulation, to carry several simultaneous channels.

Buffer: (fiber optic) A soft material which mechanically isolates individual fibers in a fiber optic cable or bundle from small geometrical irregularities, distortions or roughness of adjacent surfaces.

Buffing Stripper: A motorized device for removing flat cable insulation by means of buffing wheels that melt the insulation and brush it away from the conductors. Also called Abrasion Stripper.

Building Entrance Area: See Entrance Room or Space, Telecommunications.

Building Wire: Wire used for light and power, 600 volts or less, usually not exposed to outdoor environment.

Bunched Stranding: A group of strands twisted together in a random manner and the same direction without regard to geometric arrangement of specific strands.

Buncher: A machine that twists wires together in random arrangement.

Bundle: (fiber optic) A number of fibers grouped together, usually carrying a common signal.

Buried Cable: A cable installed directly in the earth without use of underground conduit. Also called “direct burial cable.”

Bus: Wire used to connect two terminals inside of an electrical unit.

Bushing: A mechanical device used as a lining for an opening to prevent abrasion to wire and cable.

Butt: Joining of two conductors end-to-end, with no overlap and with the axes in line.

Butt Splice: A splice wherein two wires from opposite ends butt against each other, or against a stop, in the center of a splice.

Butt Wrap: Tape wrapped around an object or conductor in an edge-to-edge condition.

Byte: Typically a group of eight binary digits.

Cable: A stranded conductor with or without insulation and other coverings (single-conductor cable), or a combination of conductors (multiple-conductor cable). In fiber optics, a jacketed fiber or jacketed bundle in a form which can be terminated.

Cable Assembly: Typically, the cable and associated connectors; ready to install.

Cable Clamp: A device used to give mechanical support to the wire bundle or cable at the rear of a plug or receptacle.

Cable Clamp Adapter: A mechanical adapter that attaches to the rear of a plug or receptacle to allow the attachment of a cable clamp.

Cable Core: The portion of an insulated cable lying under a protective covering.

Cable Core Binder: A wrapping of tapes or cords around the conductors of a multiple-conductor cable used to hold them together.

Cable Filler: The material used in multiple-conductor cables to occupy the interslices formed by the assembly of the insulated conductors, thus forming a cable core.

Cable Rack: The vertical or horizontal open support (usually made of aluminum or steel) that is attached to a ceiling or wall.

Cable Sheath: The overall protective covering applied to cables.

Cable Tray: A ladder, trough, solid-bottom or channel raceway system intended for, but not limited to, the support of telecommunications media (e.g., cable).

Cable Vulcanizer: Compression molding machine used to repair cable jacketing that has had a part removed for splicing, for adding connectors or other devices or for replacing damaged sections.

Cabling: (1) A combination of all cables, wire, cords and connecting hardware. (2) Twisting together two or more insulated conductors by machine to form a cable. In fiber optics, a method by which a group or bundle of fibers is mechanically assembled.

Cabling Factor: Used in the formula for calculating the diameter of an unshielded, unjacketed cable. D = Kd, where D is the cable diameter, K is the factor and d is the diameter of one insulated conductor.

Campus: The building and grounds of a complex (e.g. a university, college, industrial park or military establishment).

Canadian Standards Association (CSA): A non-profit independent organization which operates a listing service for electrical and electronic materials and equipment. The Canadian counterpart of the Underwriter’s Laboratories.

Capacitance: The ratio of the electrostatic charge on a conductor to the potential difference between the conductors required to maintain that charge.

Capacitance, Direct: The capacitance measured from one conductor to another conductor through a single insulating layer.

Capacitance, Mutual: The capacitance between two conductors (typically of a pair) with all other conductors, including shield, short circuited to ground.

Carolprene®: Proprietary rubber compound.

Carrier: The woven element of a braid consisting of one or more ends (strands) which creates the interlaced effect. Also, a spindle, spool, tube, or bobbin (on a braiding machine) containing yarn or wire, employed as a braid.

Cellular Plastics: Expanded or “foam,” consists of individual closed cells of inert gas suspended in a plastic medium, resulting in a desirable reduction of the dielectric constant.

Central Office: The place where communications common carriers terminate customer lines and locate switching equipment that interconnects those lines.

Certificate of Compliance (C of C): A written statement; normally generated by a quality control department, which states that the product being shipped meets customer’s specifications.

Certified Test Report (CTR): A report reflecting actual test data on the cable shipped. Tests are normally conducted by the quality control department, and show that the product being shipped meets the required test specifications.

Characteristic Impedance: The impedance that, when connected to the output terminals of a transmission line of any length, makes the line appear indefinitely long.

Chlorosulfonated Polyethylene (CSPE): A rubbery polymer used for insulations and jackets. Manufactured by E.l. DuPont under the trade name of Hypalon®.

Cigarette Wrap: Tape insulation wrapped longitudinally instead of spirally over a conductor.

Circuit: A complete path over which electrons can flow from the negative terminals of a voltage source through parts and wires to the positive terminals of the same voltage source.

Circuit Sizes: A popular term for building wire sizes 14 through 10 AWG.

Circular Mil: The area of a circle one mil (.001") in diameter; 7.854 x 10-7 sq. in. Used in expressing wire cross sectional area.

Cladding: Method of applying a layer of metal over another metal whereby the junction of the two metals is continuously welded. In fiber optics, a sheathing intimately in contact with the core of a higher refractive index material which serves to provide optical insulation and protection to the reflection interface.

Closed End Splice: An insulated splice in which two or more wires overlap and enter the splice from the same end of the barrel.

Closet, Telecommunications: An enclosed space for housing telecommunications equipment, cable terminations and cross-connect cabling. The closet is the recognized location of the cross-connect between the backbone and horizontal facilities.

Coaxial Cable: A cable consisting of two cylindrical conductors with a common axis, separated by a dielectric.

Coaxial Connector: A connector that has a coaxial construction and is used with coaxial cable.

Coherent Source: (fiber optic) A light source which emits a very narrow, unidirectional beam of light of one wavelength (monochromatic).

Coil Effect: The inductive effect exhibited by a spiral-wrapped shield, especially above audio frequencies.

Glossary

Page 218: Cross-Reference & Online Spec Sheets - Datasheet Archive

207

Technical Information Electronics

Cold Flow: Permanent deformation of the insulation due to mechanical force of pressure (not due to heat softening).

Color Code: A color system for wire or circuit identification by use of solid colors, tracers, braids, surface printing, etc.

Commercial Building: A building or portion thereof, that is intended for office use.

Common Axis Cabling: In multiple cable constructions, a twisting of all conductors about a “common axis” to result in smaller diameter constructions. Tends to result in greater susceptance to electromagnetic and electrostatic interference.

Compact Conductor: Stranded conductor rolled to deform the round wires to fill the normal interstices between the wires in a strand.

Composite (Clad) Wire: A wire having a core of one metal with a fused outer shell of different metals.

Composite Conductor: Two or more strands of different metals assembled and operated in parallel.

Compound: An insulating or jacketing material made by mixing two or more ingredients.

Compression Cable: A pipe type cable in which the pressure medium is separated from the insulation by a membrane or sheath.

Concentric: A central core surrounded by one or more layers of helically wound strands in a fixed round geometric arrangement.

Concentric-Lay Cable: A concentric-lay conductor, or a multiple-conductor cable composed of a central core surrounded by one or more layers of helically laid insulated conductors.

Concentric Strand: A strand that consists of a central wire or core surrounded by one or more layers of spirally laid wires.

Concentricity: The measurement of the location of the center of the conductor with respect to the geometric center of the circular insulation.

Conductance: The ability of a conductor to carry an electric charge. The ratio of the current flow to the potential difference causing the flow. The reciprocal of resistance.

Conductivity: The capacity of a material to carry electrical current—usually expressed as a percentage of copper conductivity (copper being 100%).

Conductor: A wire (or combination of wires not insulated from one another) suitable for carrying electric current.

Conduit: A rigid or flexible metallic or nonmetallic raceway of circular cross-section through which cables can be pulled or housed.

Connecting Hardware: A device providing mechanical cable terminations.

Connector: A device used to provide rapid connect/disconnect service for electrical cable and wire terminations.

Contact: The part of a connector which actually carries the electrical current, and are touched together or separated to control the flow.

Contact Inspection Hole: A hole in the cylindrical rear portion of contact used to check the depth to which a wire has been inserted.

Contact Size: The largest size wire which can be used with the specific contact. Also, the diameter of the engagement end of the pin.

Continuity Check: A test to determine whether electrical current flows continuously throughout the length of a single wire or individual wires in a cable.

Continuous Vulcanization: Simultaneous extrusion and vulcanization of rubber-like wire coating materials.

Contrahelical: Cable spiralling in an opposite direction than the preceding layer within a wire or cable.

Control Cable: A multi-conductor cable made for operation in control of signal circuits.

Controlled Impedance Cable: Package of two or more insulated conductors where impedance measurements between respective conductors are kept essentially constant throughout the entire length.

Copolymer: A compound resulting from the polymerization of two different monomers.

Copper-Clad: Steel with a coating of copper welded to it before drawing as opposed to copper-plated. Synonymous with Copperweld.

Copperweld: The trade name of Flexo Wire Division (Copperweld Steel Corp.) for their copper-clad steel conductors.

Cord: A small, flexible insulated cable.Cord Set: Portable cords fitted with a wiring

device at one or both ends.Cord, Telecommunications: A cable using

stranded conductors for flexibility, as in distribution cords or line cords. Line cords can also use tinsel conductors.

Core: In cables, a component or assembly of components over which other materials are applied, such as additional components, shield, sheath or armor. In fiber optics, the transparent glass or plastic section with a high refractive index through which the light travels by internal reflections.

Corona: A discharge due to ionization of air around a conductor due to a potential gradient exceeding a certain critical value.

Corona Resistance: The time that the insulation will withstand a specified level of field-intensified ionization that does not result in the immediate complete breakdown of the insulation.

Corrosion: The destruction of the surface of a metal by chemical reaction.

Coupling Loss: (fiber optic) Signal losses due to small differences in numerical aperture, core diameter, core concentricity and tolerances in splicing connectors when two fibers are aligned. Also known as Splicing Loss and Transfer Loss.

Coupling Ring: A device used on cylindrical connectors to lock plug and receptacle together.

Coverage: The calculated percentage which defines the completeness with which a metal braid covers the underlying surface. The higher percentage of coverage, the greater the protection against external interference.

Covering: Textile braid or jacket of rubber, plastics or other materials applied over wire and cables to provide mechanical protection and identification.

Crazing: The minute cracks on the surface of plastic materials.

Creep: The dimensional change with time of a material under load.

Creepage: The conduction of electricity across the surface of a dielectric.

Creepage Path: The path across the surface of a dielectric between two conductors.

Creepage Surface: An insulating surface which provides physical separation as a form of insulation between two electrical conductors of different potential.

Crimp: Act of compressing a connector barrel around a cable in order to make an electrical connection.

Crimp Termination: Connection in which a metal sleeve is secured to a conductor by mechanically crimping the sleeve with pliers, presses or automated crimping machines.

Cross-Connect: A facility enabling the termination of cable elements and their interconnection, and/or cross-connection, primarily by means of a patch cord or jumper.

Cross-Linked: Inter-molecular bonds between long-chain thermoplastic polymers by chemical or electron bombardment means. The properties of the resulting thermosetting material are usually improved.

Crosstalk: Undesired electrical currents in conductors caused by electromagnetic or electrostatic coupling from other conductors or from external sources. Also, leakage of optical power from one optical conductor to another.

CSA: Canadian Standards Association.C-SJ: Same as SJ except extra-flexible conductor.C-SJO: Same as SJO except extra-flexible

conductor.Cure: To change the physical properties of a

material by chemical reaction.Curing Cycle: The time, temperature and pressure

required for curing.Curl: The degree to which a wire tends to form a

circle after removal from a spool. An indication of the ability of the wire to be wrapped around posts in long runs.

Current: The rate of transfer of electricity. Practical unit is the ampere which represents the transfer of one coulomb per second. In a simple circuit, current (I) produced by a cell or electromotive force (E) when there is an exter nal resistance (R) and internal resistance (r) is: I =

E R + r

Current Carrying Capacity: The maximum current an insulated conductor can safely carry without exceeding its insulation and jacket temperature limitations.

Customer Premises: Building(s) with grounds and appurtenances (belongings) under the control of the customer.

Cut-Through Resistance: The ability of a material to withstand mechanical pressure, usually a sharp edge or small radius, without separation.

Cycle: The complete sequence including reversal of the flow of an alternating electric current.

Decibel (dB): A unit to express differences of power level. Used to express power gain in amplifiers or power loss in passive circuits or cables.

Delay Line: A cable made to provide very low velocity of propagation with long electrical delay for transmitted signals.

Demarcation Point: A point where the operational control or ownership changes.

Glossary

Page 219: Cross-Reference & Online Spec Sheets - Datasheet Archive

208

Electronics Technical Information

Depth of Crimp: Thickness of the crimped portion of a connector measured between two opposite points on the crimped surface.

Derating Factor: A factor used to reduce the current carrying capacity of a wire when used in environments other than that for which the value was established.

Detector: (fiber optic) A device that picks up light from fiber and converts the information into an electrical signal.

Device, As Related to a Work Station: An item such as a telephone, personal computer or graphic or video terminal.

Device, As Related to Protection: A protector, a protector mount, a protector unit or a protector module.

Dielectric: An insulating medium which intervenes between two conductors and permits electrostatic attraction and repulsion to take place across it.

Dielectric Breakdown: The voltage required to cause an electrical failure or breakthrough of the insulation.

Dielectric Constant (K): The ratio of the capacitance of a condenser with dielectric between the electrodes to the capacitance when air is between the electrodes. Also called Permittivity and Specific Inductive Capacity.

Dielectric Loss: Power dissipated in an insulating medium as the result of the friction caused by molecular motion when an AC electric field is applied.

Dielectric Strength: The voltage which an insulation can withstand before breakdown occurs. Usually expressed as a voltage gradient (such as volts per mil).

Dielectric Test: A test in which a voltage higher than the rated voltage is applied for a specified time to determine the adequacy of the insulation under normal conditions.

Digital: Transmission data representative by discrete characters.

Dip Coating: An insulating coating applied to the conductor by passing the conductor through an applicator containing liquid insulating medium.

Direct Burial Cable: A cable installed directly in the earth.

Direct Capacitance: The capacitance measured directly from conductor to conductor through a single insulating layer.

Direct Current (d.c.): An electric current which flows in only one direction.

Direct Current Resistance (DCR): The resistance offered by any circuit to the flow of direct current.

Direction of Lay: The lateral direction in which the strands of a conductor run over the top of the cable conductor as they recede from an observer looking along the axis of the conductor or cable. Also applies to twisted cable.

Discrete Wiring: Wire or wires having distinct identity and purpose.

Dispersion: (fiber optic) The variation of the refractive index of a material with wavelength, causing light of different wavelengths to travel at different velocities in the material.

Disruptive Discharge: A sudden, large increase in current through an insulation medium due to the complete failure of the medium under the electrostatic stress.

Dissipation Factor: The tangent of the loss angle of the insulating material. (Also referred to as loss tangent, tan d, and approximate power factor.)

Distribution Cable: In telecommunications and CATV systems, the transmission cable between the distribution amplifier and the drop wire.

Distribution Frame: A structure with terminations for connecting the permanent cabling of a facility in such a manner that interconnection or cross-connections may be readily made.

Disturbed Conductor: A conductor that receives energy generated by the field of another conductor or an external source such as a transformer.

Drain Wire: In a cable, the uninsulated wire laid over the component or components and used as a ground connection.

Draw Feed Stock: Rod or wire that is subsequently drawn to a smaller size.

Drawing: In wire manufacture, pulling the metal through a die or series of dies to reduce diameter to a specified size.

Drop Ceiling: See False Ceiling.Drop Wire: In telecommunications and CATV

systems, the transmission cable from the distribution cable to a dwelling.

Dual Coaxial Cable: Two individually insulated conductors laid parallel or twisted and placed within an overall shield and sheath.

Duct: 1) A single enclosed raceway for wires or cables. See also Conduit, Raceway; 2) a single enclosed raceway for wires or cables usually used in soil or concrete, 3) an enclosure in which air is moved. Generally part of the HVAC system of a building.

Duplex: Two way data transmission on a four-wire transmission line or two fiber.

Duplex Cable: (1) A cable composed of two insulated single-conductor cables twisted together. (2) A cable composed of two fibers, typically 62.5/125 mm multimode, placed in parallel under a thermoplastic sheath.

Duplex Parallel: Typically used in the thermocouple industry to denote two parallel conductors of dissimilar metals insulated in parallel without twist and jacketed. Commonly applied to thermocouple grades and extension wires.

Eccetricity: Like concentricity, a measure of the center of a conductor’s location with respect to the circular cross section of the insulation. Expressed as a percentage of displacement of one circle within the other.

Eddy Current: Circulating currents induced in conducting materials by varying magnetic fields.

Elastomer: A rubber or rubber-like material which will stretch repeatedly to 200 percent or more and return rapidly and with force to its approximate original shape.

Electro-Tinned: Electrolytic process of tinning wire using pure tin.

Electrode: A conductor through which a current enters or leaves a nonmetallic conductor.

Electromagnetic Coupling: Energy transfer by means of a varying magnetic field.

Electromagnetic Field: A rapidly moving electric field and its associated moving magnetic field.

Electromagnetic Induction: The production of a voltage in a coil due to a change in the number of magnetic lines of forces (flux linkages) passing through the coil.

Electromagnetic Interference (EMI): The interference in signal transmission or reception resulting from the radiation of electrical and magnetic fields. Synonym: Radio Frequency Interference.

Electromotive Force (e.m.f.): Pressure or voltage. The forces which cause current to flow in a circuit.

Electronic Wire and Cable: A length of conductive or semiconductive material used in an electronic application.

Electrostatic: Pertaining to static electricity, or electricity at rest. An electric charge, for example.

Elongation: The fractional increase in the length of a material stressed in tension.

Embossing: A marker identification by means of thermal indentation leaving raised lettering on the sheath material of cable.

Emergency Overload: Load which occurs when larger than normal currents are carried through a cable or wire over a certain period of time.

Enameled Wire: A conductor with a baked-on enamel film insulation. In addition to magnet wire, enameled insulation is used on thermocouple type wires and other wires.

Ends: In braiding, the number of essentially parallel wires of threads on a carrier.

Energize: To apply rated voltage to a circuit or device in order to activate it.

Entrance Facility, Telecommunications: An entrance to a building for both public and private network service cables (including antennae) including the entrance point at the building wall and continuing to the entrance room or space.

Entrance Point, Telecommunications: The point of emergence of telecommunications conductors through an exterior wall, a concrete floor slab or from a rigid metal conduit or intermediate metal conduit.

Entrance Room or Space, Telecommunications: A space in which the joining of inter- or intra-building telecommunications backbone facilities takes place. An entrance room may also serve as an equipment room.

Equilay: More than one layer of helically laid wires with the direction of lay reversed for successive layers, but with the length of lay the same for each layer.

Equipment Room, Telecommunications: A centralized space for telecommunications equipment that serves the occupants of the building. An equipment room is considered distinct from a telecommunications closet because of the nature of complexity or the equipment.

Etched Wire: A process applied to fluoroplastic wire in which the wire is passed through a sodium bath to create a rough surface to allow epoxy resin to bond the fluoroplastic.

Exit Angle: The angle between the output radiation vectors and the axis of the fiber or fiber bundle.

External Interference: The effects of electrical waves or fields which cause sounds other than the desired signal. Static.

Glossary

Page 220: Cross-Reference & Online Spec Sheets - Datasheet Archive

209

Technical Information Electronics

External Wiring: Electronic wiring which interconnects subsystems within the system.

Extruded Cable: Cable with conductors which are uniformly insulated and formed by applying a homogeneous insulation material in a continuous extrusion process.

Extrusion: Method of continuously forcing plastic, rubber, or elastomer material through an orifice to apply insulation or jacketing over a conductor or cable core.

False Ceiling: A ceiling that creates an area or space between the ceiling material and the structure above the material. Synonym: Drop Ceiling, Suspended Ceiling.

Farad: A unit of electrical capacity.Fatigue Resistance: Resistance to metal

crystallization which leads to conductors or wires breaking from flexing.

Feed-Through Insulators: Insulators that carry a metal conductor through the chassis while preventing the “hot” lead from shorting to the ground chassis.

Feedback: Energy that is extracted from a high-level point in a circuit and applied to a lower level. Positive feedback reduces the stability of a device and is used to increase the sensitivity or produce oscillation in a system. Negative feedback, also called inverse feedback, increases the stability of a system as the feedback improves stability and fidelity.

Feeder Cable: In telecommunication or CATV systems, the transmission cable from the head end (signal pickup) to the trunk amplifier. Also called a trunk cable.

Feedthrough: (1) A conductor that connects patterns on opposite sides of a PCB. Also called Interfacial connection. (2) A connector or terminal block, usually having double-ended terminals which permit simple distribution and bussing of electrical circuits.

Ferrous: Composed of and/or containing iron. A ferrous metal exhibits magnetic characteristics.

Ferrule: A short tube used to make solderless connections to shielded or coaxial cable.

Fiber: A thread or threadlike structure. Also, a single discrete element used to transmit optical (light wave) information.

Fiber Dispersion: (fiber optic) Pulse spreading in a fiber caused by differing transit times of various modes.

Fiber Optics: A lightwave or optical communications system in which electrical information is converted to light energy, transmitted to another location through optical fibers, and is there converted back into electrical information.

Fiber Tubing: A loose, crush-resistant cylinder applied over individual fibers to provide mechanical protection.

Field: An area of influence around a magnet or electric charge.

Field Coil: A suitable insulated winding to be mounted on a field pole to magnetize it.

Figure 8 Cable: An aerial cable configuration in which the conductors and the steel strand which supports the cable are integrally jacketed. A cross-section of the finished cable approximates the figure “eight.”

Filament: Fiber characterized by extreme length.

Filled Cable: A telephone cable construction in which the cable core is filled with a material that will prevent moisture from entering or passing through the cable.

Filler: (1) A material used in multiconductor cables to occupy large interstices formed by the assembled conductors. (2) An inert substance added to a compound to improve properties or decrease cost.

Film: A thin plastic sheet.Fine Stranded Wire: Stranded wire with

component strands of 36 AWG or smaller.Firestop: A material, device or assembly of parts

installed in a cable system in a fire-rated wall or floor to prevent passage of flame, smoke or gasses through the rated barrier.

Flame Resistance: The ability of a material not to propagate flame once the heat source is removed.

Flammability: The measure of the material’s ability to support combustion.

Flashover: A disruptive discharge around or over the surface of a solid or liquid insulator.

Flat Braid: A woven braid of tinned copper strands rolled flat at time of manufacture to a specified width.

Flat Cable: A cable with two smooth or corrugated but essentially flat surfaces.

Flat Conductor: A wire having a rectangular cross-section as opposed to a round or square conductor.

Flat Conductor Cable: A cable with a plurality of flat conductors.

Flexfoil®: Proprietary aluminum laminated shielding tapes.

Flex Life: The measurement of the ability of a conductor or cable to withstand repeated bending.

Flexibility: The ease with which a cable may be bent.

Flexible: That quality of a cable or cable component which allows for bending under the influence of outside force, as opposed to limpness which is bending due to the cable’s own weight.

Floating: Referring to a circuit which has no connection to ground.

Flux: (1) The lines of force which make up an electrostatic field. (2) The rate of flow of energy across or through a surface. (3) A substance used to promote or facilitate fusion.

FNC: Federal Networking Council (formerly FRICC).

Foamed Plastics: See Cellular Plastic.Foil: A thin, continuous sheet of metal.Free Connector: A connector for attachment to

the free end of a wire or cable.Frequency: The number of times a periodic

action occurs in a unit of time. The number of cycles that an electric current completes in one second.

Frequency Response: The characteristic of a device denoting the range of frequencies over which it may be used effectively.

Funnel Entry: Flared or widened entrance to a terminal or connector wire barrel.

Fuse Wire: Wire made from an alloy that melts at a relatively low temperature.

Fused Coating: A metallic coating which has been melted and solidified, forming a metallurgical bond to the base material.

Fused Conductors: Individual strands of heavy tinned copper wire stranded together and then bonded together by induction heating.

Fused Spiral Tape: A PTFE insulated hookup wire. The spiral wrapped conductor is passed through a sintering oven where overlaps are fused together.

Gain: The increase of voltage, current or power over a standard or previous reading. Usually expressed in decibels.

Galvanometer: An instrument for detecting or measuring small electrical current.

Gas-Filled Cable: A self-contained pressure cable in which the pressure medium is an inert gas having access to the insulation.

Gauge: A term used to denote the physical size of a wire.

Giga: A numerical prefix denoting one billion (109).Gigahertz (GHz): A unit of frequency equal to one

billion hertz.Gimmick: A short length of wire soldered onto

a circuit component and used as a small adjustable capacitor.

Graded-lndex: A type of optical fiber in which the refractive index of the core is in the form of a parabolic curve, decreasing toward the cladding. This type of fiber provides high bandwidth capabilities.

Ground: A conducting connection, whether intentional or accidental, between an electrical circuit (e.g. telecommunications) or equipment and the earth, or to some conducting body that serves in place of the earth.

Ground Conductor: A conductor in a transmission cable or line that is grounded.

Ground Insulation: The insulation used between a winding and the magnetic core or other structural parts, usually at ground potential.

Ground Loop: The generation of undesirable current flow within a ground conductor, owing to the circulation currents which originate from a second source of voltage.

Ground Plane: Expanded copper mesh which is laminated into some flat cable constructions as a shield.

Ground Potential: Zero potential with respect to the ground or earth.

Hard Drawn Copper Wire: Copper wire that has not been annealed after drawing.

Harness: An arrangement of wires and cables usually with many breakouts, which have been tied together or pulled into a rubber or plastic sheath, used to interconnect an electric circuit.

Hash Mark Stripe: A non-continuous helical stripe applied to a conductor for identification.

Heat Distortion: Distortion of flow of a material or configuration due to the application of heat.

Heat Seal: Method of sealing a tape wrap jacket by means of thermal fusion.

Heater Cord: Flexible stranded copper conductor, cotton wrapped, with rubber insulation and asbestos roving.

Helical Stripe: A continuous, colored, spiral stripe applied to a conductor for circuit identification.

Helix: Spiral winding.Henry: The unit of inductance.Hertz (Hz): A term replacing cycles-per-second as

an indication of frequency.Heterogeneous Insulation: A cable insulating

system composed of two or more layers of different insulating materials.

Glossary

Page 221: Cross-Reference & Online Spec Sheets - Datasheet Archive

210

Electronics Technical Information

High-Temperature Wire and Cable: Electrical wire and cables having thermal operating characteristics of 150°C and higher.

High Voltage: Generally, a wire or cable with an operating voltage of over 600 volts.

Holding Strength: Ability of a connector to remain assembled to a cable when under tension.

Homogeneous Insulation: A complete cable insulation structure whose components cannot be identified as layers of different materials.

Hook-up Wire: A wire used for low-current, low- voltage (under 1000 volts) applications within enclosed electronic equipment.

Horizontal Cabling: The wiring/cabling between the telecommunications outlet/connector and the horizontal cross-connect.

Horizontal Cross-Connect: A cross-connect of horizontal cabling to other cabling, e.g. horizontal, backbone or equipment.

Hot Stamping: Method of alpha numerical coding. Identification markings are made by pressing heated type and marking foil into softened insulation surfaces. See Surface Printing.

Hot Tin Dip: A process of passing bare wire through a bath of molten tin to provide a coating.

Hybrid Cable: An assembly of two or more cables (of the same or different types or categories) covered by one overall sheath.

Hygroscopic: Capable of absorbing moisture from the air.

Hypalon®: DuPont’s trade name for their chlorosulfonated polyethylene, an ozone- resistant synthetic rubber.

Impact Tool: Device used to punch new conductor onto IDs. This tool is typically equipped with a cutting blade for either 66 or 110 blocks.

Impedance: The total opposition that a circuit offers to the flow of alternating current or any other varying current at a particular frequency. It is a combination of resistance R and reactance X, measured in Ω.

Impedance-Matching Transformer: A transformer designed to match the impedance of one circuit to that of another (BALUN).

Impulse: A surge of unidirectional polarity.Impulse Strength: The voltage breakdown of

insulation under voltage surges on the order of microseconds in duration.

Impulse Test: An insulation test in which the voltage applied is an impulse voltage of specified wave shape.

Incoherent Source: (fiber optic) A light source which emits wide, diffuse beams of light of many wave lengths.

Index-Matching Fluid: (fiber optic) Fluid with refractive index same as fiber core; used to fill air gap between fiber ends at connectors.

Index of Refraction: The ratio of light velocity in a vacuum to its velocity in a given transmitting medium.

Inductance: The property of a circuit or circuit element that opposes a change in current flow, thus causing current changes to lag behind voltage changes. It is measured in henrys.

Inductive Coupling: Crosstalk resulting from the action of the electromagnetic field of one conductor on the other.

Infrastructure, Telecommunications: A collection of those telecommunications components, excluding equipment, that together provide the basic support for the distribution of all information within a building or campus.

Insertion Loss: As measure of the attenuation of a device by determining the output of a system before and after the device is inserted into the system.

Insertion Tool: A small, hand-held tool used to insert contacts into a connector.

Insulated Wire: A conductor of electricity covered with a non-conducting material.

Insulating Joint: A device which mechanically couples and electrically insulates the sheath and armor of contiguous lengths of cable.

Insulation: A material having high resistance to the flow of electric current. Often called a dielectric in radio frequency cable.

Insulation Adhesion: The degree of tightness of the insulation over the base conductor, measured in terms of force required to remove a specified length of insulation from the wire.

Insulation Crimp: The area of a terminal, splice or contact that has been formed around the insulation of the wire.

Insulation Grip: Extended cylinders at the rear of crimp-type contacts designed to accept the bared wire and a small length of its insulation.

Insulation Piercing: A method of crimping whereby lances cut the insulation of the wires and enter into the strands to make electrical contact.

Insulation Resistance: The ratio of the applied voltage to the total current between two electrodes in contact with a specific insulation, usually expressed in megΩ-M feet.

Insulation System: All of the insulation materials used to insulate a particular electrical or electronic product.

Integral Belt: A layer of insulation or semiconductive material applied by extrusion over two or more insulated, twisted or parallel conductors, to form a round, smooth diameter.

Interconnect: A connection scheme that provides for the direct connection of individual cables to another cable or to an equipment cable without a patch cord.

Interconnecting Cable: The wiring between modules, between units or the larger portions of a system.

Interconnecting Wire: The physical wiring between components (outside a module), between modules, between units or between larger portions of a system or systems.

Interconnection: Mechanically joining devices together to complete an electrical circuit.

Interface: The two surfaces on the contact side of both halves of a multiple-contact connector which face each other when the connector is assembled.

Intermediate Cross-Connect: A cross-connect between 1st level and 2nd level backbone cabling.

Internal Wiring: Electronic wiring which interconnects components, usually within a sealed subsystem.

Interstices: Voids or valleys between individual strands in a conductor or between insulated conductors in a multiconductor cable.

Ionization Voltage (Corona Level): The minimum value of falling rms voltage which sustains electrical discharge within the vacuous or gas-filled spaces in the cable construction or insulation.

Irradiation: In insulations, the exposure of the material to high energy emissions for the purpose of favorably altering the molecular structure.

Jack: A plug-in type terminal widely used in an electronic apparatus for temporary connections.

Jacket: An outer protective sheath over primary insulation, braids, shields, cable components or over the cable itself. In fiber optics, a covering, over a fiber, bundle of fibers or cable which protects against the environment.

JAN Specification: Joint Army-Navy specification (replaced by current Military Specifications).

Jumper: An assembly of twisted pairs without connectors, used to join telecommunications circuits/links at the cross connect.

Junction: A point in a circuit where two or more wires are connected.

Keying: The mechanical feature of a connector system that guarantees correct orientation of a connection, or prevents the connection to a jack, or to an optical fiber adapter of the same type intended for another purpose.

Kynar®: Pennwalt trade name for polyvinylidene fluoride. Typically used as insulation for wire wrap wire.

Lacing and Harnessing: A method of grouping wires by securing them in bundles of designated patterns.

Lacquer: A liquid resin or compound applied to textile braid to prevent fraying, moisture absorption, etc.

Laminated Tape: A tape consisting of two or more layers of different materials bonded together.

Laser Diode: (fiber optic) A semiconductor diode that, when pulsed, a laser diode emits coherent light.

Launch Angle: (fiber optic) The angle between the radiation vector and the axis of the fiber or fiber bundle.

Lay: The length measured along the axis of a wire or cable required for a single strand (in stranded wire) or conductor (in cable) to make one complete turn about the axis of the conductor or cable.

Layer: Consecutive turns of a coil lying in a single plane.

Leaching and Non-Leaching: In a leaching wire, the plasticizer will migrate when exposed to heat. A non-leaching wire will retain its plasticizer under extreme temperature conditions and remain flexible after baking.

Lead: A wire, with or without terminals, that connects two points in a circuit.

Lead-Cured: A cable that is cured or vulcanized in a metallic lead mold.

Lead Dress: The placement or routing of wire and component leads in an electrical circuit.

Lead-in: The conductor or conductors that connect the antenna proper to electronic equipment.

Leakage Current: The undesirable flow of current through or over the surface of an insulation.

Glossary

Page 222: Cross-Reference & Online Spec Sheets - Datasheet Archive

211

Technical Information Electronics

Life Cycle: A test to determine the length of time before failure in a controlled, usually accelerated, environment.

Light Commercial Building: A building or portion thereof that is intended for use with one to four (1-4) non-residential exchange access lines per tenant.

Light-Intensity Ratio: (fiber optic) Ratio of input light intensity to the output light intensity.

Light Source: (fiber optic) An object capable of emitting light. In fiber optics, the light source is normally an LED or a laser.

Lightguide: (fiber optic) A flexible bundle of fibers used to transmit light.

Lightwave Communications: (fiber optic) Communications using light to carry the information.

Limits of Error: The maximum deviation (in degrees of percent) of a thermocouple or thermocouple extension wire from standard emf-temperature to be measured.

Limpness: The ability of a cable to lay flat or conform to a surface.

Line Balance: The degree to which the conductors of a cable are alike in their electrical characteristics with respect to each other, to other conductors and to ground.

Line Drop: A voltage loss occurring between any two points in a transmission line, due to the resonance, reactance or leakage of the line.

Line Loss: The total of the various energy losses occurring in a transmission line.

Line Voltage: Voltage existing in a cable or circuit.Link: An assembly of telecommunications

facilities between two points, not including terminal equipment.

Listed: Equipment included in a list published by an organization, acceptable to the authority having jurisdiction, that maintains periodic inspection of production of listed equipment, and whose listing states either that the equipment or material meets appropriate standards or has been tested and found suitable for use in a specified manner.

Local Area Network (LAN): A geographically limited communications network intended for the local transport of data, video and voice.

Longitudinal Shield: A tape shield, flat or corrugated, applied longitudinally with the axis of the core being shielded.

Longitudinal Wrap: Tape applied longitudinally with the axis of the core being covered.

Loop Resistance: The total resistance of two conductors measured round-trip from one end. Commonly used term in the thermocouple industry.

Looping-in: Wiring method which avoids tee joints by carrying the conductor or cable to and from the point to be supplied.

Loss: Energy dissipated without accomplishing useful work.

Loss Factor: The product of the dissipation and dielectric constant of an insulating material.

Lossy Line: A cable having large attenuation per unit of length.

Low-Loss Dielectric: An insulating material that has a relatively low dielectric loss, such as polyethylene or Teflon®.

Low-Noise Cable: Cable configuration specially constructed to eliminate spurious electrical disturbances caused by capacitance changes or self-generated noise induced by either physical abuse or adjacent circuitry.

Low Tension: Low voltage, as applied to ignition cable.

Lug: Termination, usually crimped or soldered to the conductor, with provision for screwing on to the terminal.

m: Meter.Magnet Wire: Insulated wire intended for use in

windings on motor, transformer and other coils for electromagnetic devices.

Magnetic Field: The region within which a body or current experiences magnetic force.

Magnetic Flux: The rate of flow of magnetic energy across or through a surface (real or imaginary).

Magnetic Noise: Caused by change in current level, e.g. ac powerline (creates magnetic field around the cable) this magnetic field causes the magnetic noise.

Main Cross-Connect: A cross-connect for 1st level backbone cables, entrance cables and equipment cables.

Marker Tape: A tape laid parallel to the conductors under the sheath in a cable, imprinted with the manufacturer’s name and the specification to which the cable is made.

Master Antenna Television (MATV): A combination of components providing multiple television receiver operations from one antenna or group of antennas normally on a single building.

Material Scattering Loss: (fiber optics) Loss due to fluctuations in the refractive index and to inhomogeneities in material composition and temperature.

Media, Telecommunications: Wire, cable or conductors used for telecommunications.

Megarad: A unit for measuring radiation dosage.Messenger: Supporting member, usually a high-

strength steel wire, used to suspend aerial cable. The messenger may be an integral part of the cable, or exterior to it (lashed messenger).

Microbending Loss: (fiber optic) Loss due to small geometrical irregularities along the core-clad interface of the fiber.

Microfarad: One-millionth of a farad, commonly abbreviated m-F.

Micromicrofarad: One-millionth of a microfarad. (uuf, uufd, mmf, mmfd m‑m F are common abbreviations.)

Microwave: A short (usually less than 30 cm.) electrical wave.

Mil: A unit used in measuring diameter of a wire or thickness of insulation over a conductor. One-one thousandth of an inch (.001").

Mineral-Insulated: Cable and thermocouple wire consisting of one or more conductors surrounded by magnesium oxide insulation and enclosed in a liquid- and gas-tight metallic sheathing.

Miniature Wire: Insulated conductors of approximately 20-34 AWG.

Mis-Match: A termination having a different impedance than that for which a circuit or cable is designed.

Mode: One of the components of a general configuration of a propagating wave front.

Modem: Device which places and receives data signals over a common carrier’s communication facility.

Modular Jack: This term is outmoded; see Outlet/Connector, Telecommunications.

Modular Plug: A telecommunications connector for wire or cords per the Part 68 Rules. A modular plug can have 6 or 8 contact positions, but not all the positions need be equipped with contacts.

Modulation: A process whereby certain characteristics of a wave, often called the carrier, are varied or selected in accordance with a modulating function.

Modulus of Elasticity: The ratio of stress to strain in an elastic material.

Moisture Absorption: The amount of moisture, in percentage, that a material will absorb under specified conditions.

Moisture Resistance: The ability of a material to resist absorbing moisture from the air or when immersed in water.

Molded Plug: A connector molded on either end of a cord or cable.

Monomer: The basic chemical unit used in building a polymer.

Motor Lead Wire: Wire which connects to the fragile magnet wire found in coils, transformers and stator or field windings.

Multiconductor: More than one conductor within a single cable complex.

Multimode Optical Fiber: An optical fiber that will allow many bound modes to propagate. The fiber may be either a graded-index or step-index fiber. See also: Optical Fiber Cable.

Multiple Conductor Cable: A combination of two or more conductors cabled together and insulated from one another and from sheath or armor where used.

Multiple Conductor Concentric Cable: An insulated central conductor with one or more tubular stranded conductors laid over it concentrically and insulated from one another.

Multiplexing: Simultaneous transmission of two or more messages over the same cable pair.

Mutual Capacitance: Capacitance between two conductors when all other conductors are connected together to shield and ground.

Mylar®: DuPont trademark for polyester film.Nanometer (nm): One billionth of a meter

(10 –9 meter).Nanosecond: One billionth of a second

(10 -9 seconds).National Electric Code (NEC): A set of

regulations governing construction and installation of electrical wiring and apparatus in the United States, established by the American National Board of Fire Underwriters.

Neoprene: A synthetic rubber with good resistance to oil, chemical and flame. Also called polychloroprene.

Noise: In a cable or circuit, any extraneous signal which tends to interfere with the signal normally present in or passing through the system.

Nomex®: DuPont trademark for a temperature- resistant, flame-retardant nylon.

Non-Contaminating: Type of PVC jacket material whose plasticizer will not migrate into the dielectric of a coaxial cable and thus avoids contaminating and destroying the dielectric.

Glossary

Page 223: Cross-Reference & Online Spec Sheets - Datasheet Archive

212

Electronics Technical Information

Nylon: Thermoplastic with good chemical and abrasion resistance.

NVP: Nominal Velocity of Propagation.Off Center: Conductor displaced within the cross-

section of its insulation.Offgassing: Percentage of a specified gas

released during the combustion of insulation or jacketing material.

Ohm: A unit of electrical resistance.Oil Aging: Cable aged in an accelerated manner

by placement in an oil bath and heated to a pre-set temperature for a stated time.

Oil-Filled Cable: A self-contained pressure cable in which the pressure medium is low viscosity oil having access to the insulation.

Opaque: (fiber optic) Not permitting the passage of light.

Open Cell: Foamed or cellular material with cells which are generally interconnected.

Optical Communication Cable: (fiber optic) Fiber with a protective jacket around it.

Optical Conductors: (fiber optic) Materials which offer a low optical attenuation to transmission of light energy.

Optical Fiber Cable: An assembly consisting of one or more optical fibers.

Optical Fiber Duplex Adapter: A mechanical media termination device designed to align and join two duplex connectors.

Optical Fiber Duplex Connector: A mechanical media termination device designed to transfer optical power between two pairs of optical fibers.

Optical Waveguide: (fiber optic) A fiber used for optical communications. Analogous to a waveguide used for microwave communications.

Oscillatory Surge: A surge which includes both positive and negative polarity values.

Outgassing: The dissipation of gas from a dielectric evidencing decomposition.

Outlet Box, Telecommunications: A metallic or nonmetallic box mounted within a wall, floor or ceiling and used to hold telecommunications outlet/connectors or transition devices.

Outlet/Connector, Telecommunications: A connecting device in the work area on which horizontal cable terminates.

Overall Diameter: Finished diameter over wire or cable.

Overcoat Conductor: A stranded conductor made from individual strands of tin-coated wire stranded together, and then given an overall tin coat.

Overlap: The amount the trailing edge laps over the leading edge of a spiral tape wrap.

Oxygen Index: Percentage of oxygen necessary to support combustion in a gas mixture.

Ozone: Reactive form of oxygen, typically found around electrical discharges and present in the atmosphere in small quantities.

Packing Fraction: (fiber optic) The ratio of active cross-sectional area of fiber core, or cores, to the total end surface of the fiber, or fiber bundle.

Pair: Two insulated wires of a single circuit associated together, also known as a “balance” transmission line.

Parallel Pair: A duplex construction of two insulated conductors laid parallel and then covered overall with a braid or jacket.

Parallel Stripe: A stripe applied longitudinally on a wire or cable parallel to the axis of the conductor.

Patch Cord: A length of cable with connectors on one or both ends used to join telecommunications links/circuits at the cross-connect.

Patch Cord Cable: Bulk cable used in the manufacture of patch cords.

Patch Panel: A cross-connect system of mateable connectors that facilitates administration.

Pathway: A facility for the placement of telecommunications cable. Synonym: Raceway.

Pay-Off: The process of feeding a cable or wire from a bobbin, reel or other package.

Percent Plating: Quantity of plating on a conductor expressed as a percentage by weight.

Percentage Conductivity: Conductivity of a material expressed as a percentage of that of copper.

Periodicity: The uniformly spaced variations in the insulation diameter of a transmission cable that result in reflections of a signal, when its wavelength or a multiple thereof is equal to the distance between two diameter variations.

Permittivity: See Dielectric Constant.Phase: An angular relationship between waves.Phase Shift: A change in the phase relationship

between two alternating quantities.Photodetector (Receiver): Converts light energy

to electrical energy.Pick: Distance between two adjacent crossover

points of braid filaments. The measurement in picks per inch indicates the degree of coverage.

Picofarad: One-millionth of one-millionth of a farad. A micromicrofarad or picofarad (abbreviation pf). (See mm F).

Pigtail Wire: Fine-stranded, extra-flexible, rope- lay lead wire attached to a shield for terminating purposes.

Pitch: In flat cable, the nominal distance between the index edges of two adjacent conductors.

Pitch Diameter: Diameter of a circle passing through the center of the conductors in any layer of a multiconductor cable.

Plain Conductor: A conductor consisting of only one metal.

Plain Weave: A weave used on woven cables. Threads between the wires act as binders and give the cable lateral stiffness and linear flexibility. Also called Standard and Square Weave.

Planetary Cabler: A cabler capable of laying down any number of shielded, overbraided or jacketed singles, pairs, called groups, or any combination of them in sequence.

Planetary Twister: A twisting machine whose payoff spools are mounted in rotating cradles that hold the axis of the spool in a fixed direction as the spools are revolved so no twist is built up in each wire.

Plastic Deformation: Change in dimensions under load that is not recovered when the load is removed.

Plasticizer: A chemical agent added to plastics to make them softer and more pliable.

Plenum: The air return path of a central air handling system, either ductwork or open space over a suspended ceiling.

Plenum Cable: Cable approved by a recognized agency such as UL for installation in plenums without the need for conduit.

Plug: The part of the two mating halves of a connector which is moveable when not fastened to the other mating half.

Ply: The number of individual strands or filaments twisted together to form a single thread.

Point-to-Point: A type of connection established between two specific locations, as between two buildings.

Point-to-Point Wiring: An interconnecting technique wherein the connections between components are made by wires routed between connecting points.

Polarization: The orientation of a flat cable or a rectangular connector.

Polishing: (fiber optic) Act of smoothing ends of fibers to an ‘optically smooth’ finish, generally using abrasive.

Polyester: Polyethylene terephthalate, used extensively as a moisture-resistant cable core wrap.

Polyethylene: A thermoplastic material having excellent electrical properties.

Polyhalocarbon: A general name for polymers containing halogen atoms. The halogens are fluorine, chlorine, bromine and iodine.

Polymer: A material of high molecular weight formed by the chemical union of monomers.

Polyolefin: Any of the polymers and copolymers of the ethylene family of hydrocarbons.

Polypropylene: A thermoplastic similar to polyethylene but stiffer and having higher softening point (temperature); excellent electrical properties.

Polyurethane: Class of polymers known for good abrasion and solvent resistance (may be applied in solid or cellular form).

Porosity: Multiple voids in an insulation cross-section.

Potting: The sealing of a cable termination or other component with a liquid which thermosets into an elastomer.

Power Cables: Cables of various sizes, construction and insulation, single or multi-conductor designed to distribute primary power to various types of equipment.

Power Factor: The ratio of resistance to impedance. The ratio of the actual power of an alternating current to apparent power. Mathematically, the cosine of the angle between the voltage applied and the current resulting.

Pre-Bond: Stranded wire which has been fused, topcoat-tinned or overcoat-tinned.

Prewiring: Wiring installed • Before walls are enclosed or finished. • In anticipation of future use or need.

Primary: The transformer winding which receives the energy from a supply circuit.

Primary Insulation: The first layer of non-conductive material applied over a conductor, whose prime function is to act as electrical insulation.

Primary Protection: The minimum protection required on all exposed facilities to comply with NEC requirements.

Primary Wiring: A printed circuit intended to provide point-to-point electrical connections.

Programming: Ability to select various circuit patterns by interconnecting appropriate contacts on one side of a connector plug or panel.

Propagation Delay: Time delay between input and output of signal.

Glossary

Page 224: Cross-Reference & Online Spec Sheets - Datasheet Archive

213

Technical Information Electronics

Propagation Time: Time required for a wave to travel between two points on a transmission line.

Protocol: A set of rules for communicating.Proximity Effect: Nonuniform current distribution

over the cross-section of a conductor caused by the variation of the current in a neighboring conductor.

Pull Box: A device to access a raceway used to facilitate placing of wire or cables.

Pull Cord/Pull Wire: Cord or wire placed within a raceway and used to pull wire and cable through the raceway.

Pull Strength: See Pull Tension.Pull Tension: The maximum pulling force that can

be safely applied to a cable without damage.Pulling Eye: A device used to pull cable into or

from a duct.Pulse: Energy which changes abruptly from an

intensity to another. May be light energy or electrical energy.

Pulse Cable: A type of coaxial cable constructed to transmit repeated high-voltage pulses without degradation.

Polyvinyl Chloride (PVC): A general-purpose thermoplastic widely used for wire and cable insulations and jackets.

Quad: A series of four separately insulated conductors, generally twisted together in pairs. Also, a series-parallel combination of transistors with increased reliability because failure of one transistor will not disable the entire circuit.

Quadders: Three-bay machines which can twist four wires together and cable braided and shielded wires with varying lay lengths.

Raceway: Any channel designed for holding wires or cables, e.g. conduit, electrical metallic tubing, sleeves, slots, underfloor raceways, cellular floors, surface raceways, lighting fixture raceways, wireways, cable troughs, busways, auxiliary gutters and ventilated flexible cableways. Synonym: Pathway.

Rack: See: Cable Rack.Radio Frequency: The frequencies in the

electromagnetic spectrum that are used for radio communications.

Random Winding: A winding in rotating equipment wherein the wires do not lie in an even pattern.

Reactance: The opposition offered to the flow of alternating current by inductance or capacitance of a compound or circuit.

Red Plaque: A powdery, brown-red growth found on silvercoated copper conductors and shield braids.

Redraw: The consecutive drawing of wire through a series of dies to reach a desired wire size.

Reducing Joint: A joint between two lengths of cable where the conductors are not the same size.

Reel: A revolvable flanged device made of wood or metal, used for winding flexible metal wire or cable.

Reflection: (fiber optic) Change in direction of a light wave or ray.

Reflection Loss: The part of a signal which is lost due to reflection of power at a line discontinuity.

Refraction: (fiber optic) The bending of lightwaves or rays as they go from one material to another due to the difference in velocities in the materials.

Reinforced Sheath: The outermost covering of a cable that has cable sheath constructed in layers with the addition of a reinforcing material, usually a braided fiber, molded in place between layers.

Remanence: The magnetic induction that remains in a magnetic circuit after the removal of an applied magnetomotive force.

Repeater: A device which consists of a transmitter and a receiver or transmitter, used to regenerate a signal to increase the system transmission length.

Resistance: A measure of the difficulty in moving electrical current through a medium when voltage is applied. It is measured in Ω.

Resistive Conductor: A conductor with high electric resistance.

Retractile Cord: A cord having specially treated insulation or jacket so that it will retract.

Return Wire: A ground wire or the negative wire in a direct-current circuit.

Ribbon Cable: A flat cable of individually insulated conductors lying parallel and held together by means of adhesive or woven textile yarn.

Ridge Marker: One or more ridges running laterally along the outer surface of a plastic- insulated wire for purposes of identification.

Rigid Bay: Cabling equipment that maintains component sequence, and can produce cables with distinct layers.

Rigid Coaxial Cable: Nonflexible coaxial cable, usually a metal tube armored coaxial cable.

Ring Tongue: A solderless terminal that connects wire to a stud.

Ringing Out: Locating or identifying specific conductive paths by passing current through selected conductors.

Rip-Cord: 1.) Two or more insulated conductors in a parallel configuration which may be separated to leave the insulation of each conductor intact. 2.) A small filament cord used to rip through the outer cable sheath.

RoHS (Restriction on Hazardous Substances): European Union directive that restricts use of heavy metal substances.

Rope Concentric: A group of standard conductors assembled in a concentric manner.

Rope Lay Conductor: A conductor composed of a central core surrounded by one or more layers of helically laid groups of wires.

Rope Unilay: A group of stranded conductors assembled in a unilay manner.

Round Wire Shields: Shields constructed from bare, tinned or silver-plated copper wire that include braided, spiral and reverse spiral.

Routers: A device that determines how to forward a packet toward its destination, based on tables that indicate the costs, congestion status and other factors associated with possible routes. Also called a level 3 relay or an intermediate system.

Rubber (Wire Insulation): Term used to describe wire insulations made of thermosetting elastomers; occurs naturally or may be made synthetically.

Rulan®: DuPont’s trade name for their flame- retardant polyethylene insulating material.

Screen: A shield placed over the entire core.Secondary Insulation: A nonconductive material

that protects the conductor against abrasion and provides a second electrical barrier.

Segmental Conductor: A stranded conductor consisting of three or more stranded conducting elements, each element having approximately the shape of the sector of a circle, assembled to give a substantially circular cross-section.

Selenium Cure: Process used to cure neoprene and rubber jacketed wires and cables.

Self-Extinguishing: Characteristic of a material whose flame is extinguished after the igniting flame source is removed.

Semi-Conducting Jacket: A jacket having a sufficiently low resistance so that its outer surface can be kept at substantially ground potential.

Semi-Rigid: A cable containing a flexible inner core and a relatively inflexible sheathing.

Semi-Solid: An insulation cross-section having a partially open space between the conductor and the insulation perimeter.

Separator: A layer of insulating material which is placed between a conductor and its dielectric between a cable jacket and the components it covers, or between various components of a multiple-conductor cable.

Series Circuit: A circuit in which the components are arranged end to end to form a single path for current.

Serve: A filament or group of filaments such as fibers or wires, wound around a central core.

Serving: A wrapping applied over the core of a cable or over a wire.

Sheath: See Cable Sheath.Shield: In cables, a metallic layer placed around

a conductor or group of conductors to prevent electrostatic or electromagnetic interference between the enclosed wires or external fields.

Shield Coverage: Amount of outer cable covered by the shielding material.

Shield Effectiveness: The ability of a shield to screen out undesirable signals.

Shielded Line: A transmission line whose elements confine propagated radio waves to an essentially finite space inside a tabular conducting surface called the sheath, thus preventing the line from radiating radio waves.

Shielded-Type Cable: A cable in which the surface of the insulation is at ground potential.

Shunt Wire: A conductor joining two parts of an electric circuit to divert part of the current.

Signal: A current used to convey information, either digital, analog, audio or video.

Silicone: A material made from silicon and oxygen. Can be in thermosetting elastomer or liquid form. The thermosetting elastomer form is noted for high heat resistance.

Silicone Treating: A silicone liquid treatment applied to insulated conductors to allow for easy jacket stripping.

Sine Wave: A wave that can be expressed as the sine of a linear function of time, or space or both.

Single-ended: Unbalanced, such as grounding one side of a circuit or transmission line.

Single-Faced Tape: Fabric tape finished on one side with a rubber or synthetic compound.

Singlemode Fiber: A fiber wave guide in which only one mode will propagate. The fiber has a very small core diameter of approximately 8mm. It permits signal transmission at extremely high bandwidths and is generally used with laser diodes.

Glossary

Page 225: Cross-Reference & Online Spec Sheets - Datasheet Archive

214

Electronics Technical Information

Sizing: Applying a material to a surface to fill pores.

Skeleton Braid: Widely separated braid of fiber copper or steel, used to hold core together, for reinforcing jacket or for shielding.

Skew Rays: A ray that does not intersect the fiber axis. Generally, a light ray that enters the fiber core at a very high angle.

Skim Tape: Filled tape coated on one or both sides with a thin film of uncured rubber or synthetic compound to produce a coating suitable for vulcanization.

Skin Effect: The tendency of alternating current, as its frequency increases, to travel only on the surface of a conductor.

Sleeve: A braided, knitted or woven tube used over wires or components as insulation tubing. Also called Sleeving.

Solid Conductor: A conductor consisting of a single wire.

Source Coupling Loss: (fiber optic) Loss of light intensity as light from source passes into fiber.

Space, Telecommunications: An area used for housing the installation and termination of telecommunications equipment and cable, e.g. telecommunications closets, work areas and manhole/handholes.

Span: (1.) In flat conductors, distance between the reference edge of the first and the last conductor. (2.) In round conductors, distance between centers of the first and last conductors. (3.) In aerial cable, the distance between poles or support clamps.

Spark Test: A test designed to locate pin-holes in the insulation of a wire or cable by application of a voltage for a very short period of time while the wire is being drawn through the electrode field.

Specific Gravity: The ratio of the density (mass per unit volume) of a material to that of water.

Spectral Bandwidth: The difference between wavelengths at which the radiant intensity of illumination is half its peak intensity.

Spectral Response: (fiber optic) The response of a detector (or a system) over different wavelengths.

Spectrum: Frequencies that exist in a continuous range and have a common characteristic.

Speed of Light (c): 2.998 x 108 meters per second.

Spiral Shield: A metallic shield of fine-stranded wires applied spirally rather than braided.

Spiral Stripe: A color-coding stripe applied helically to the surface of an insulated wire or cable.

Spiral Wrap: The helical wrap of a tape or thread over a core.

Splice: A joining of conductors, generally from separate sheaths.

Splice Closure: A device used to protect a cable or wire splice.

Spread Spectrum: A modulation technique for multiple access, or for increasing immunity to noise and interference.

Standing Wave: The stationary pattern of waves produced by two waves of the same frequency traveling in opposite directions on the same transmission line.

Standing Wave Ratio (SWR): In a transmission line, waveguide, or analogous system, a figure of merit used to express the efficiency of the system in transmitting power.

Star Topology: A topology in which each telecommunications outlet/connector is directly cabled to the distribution device.

Stay Cord: A component of a cable used to anchor the cable ends at their points of termination and to keep any pull of the cable from being transferred to the electrical connections.

Step Index Fiber: (fiber optic) A multimode fiber consisting of a core of uniform refractive index surrounded by cladding of slightly lower refractive index.

Strand: One of the wires of any stranded conductor.

Strand Lay: The distance of advance of one strand of a spirally stranded conductor, in one turn, measured axially.

Stranded Conductor: A conductor composed of groups of wires twisted together.

Strap: Square- or rectangular-section bare conductor manufactured and used in coil form.

Strip: To remove insulation from a cable.Structural Return Loss: Backward reflected

energies from uneven parts of the cable structure causing impedance variations are termed structural return loss.

Surface Resistivity: The resistance of a material between two opposite sides of a unit square of its surface. It is usually expressed in Ω.

Surge: A temporary and relatively large increase in the voltage or current in an electric circuit or cable. Also called Transient.

Suspended Ceiling: See False Ceiling.Sweep-test: Pertaining to cable, the frequency

response is verified by generating an rf voltage whose frequency is swept repeatedly through a given frequency range at a rapid constant rate while the cable response is observed.

Take-Up: The process of accumulating wire or cable onto a reel, bobbin or some other type of pack. Also, the device for pulling wire or cable through a piece of equipment or machine.

Tank Test: A voltage dielectric test in which the test sample is submerged in water and voltage is applied between the conductor and water as ground.

Tape: A relatively narrow woven or cut strip of fabric, paper or film material.

Tape Cable: A form of multiple conductor consisting of parallel metal strips imbedded in insulating material.

Tape Wrap: A spirally applied tape over an insulated or uninsulated wire.

Taped Insulation: Insulation of helically wound tapes applied over a conductor or over an assembled group of insulated conductors.

Taping: Process of insulating continuous length, large diameter wires with tape of non-extrudable materials.

TB: Terminal BlockTear Strength: The force required to initiate or

continue a tear in a material under specified conditions.

Teflon®: DuPont company trade name for fluorocarbon resins. FEP, PFA and TFE are typical materials.

Tefzel®: DuPont trade name for a fluorocarbon material typically used as a wire wrap insulation.

Telecommunications: The communication of information over some distance, including interbuilding and intrabuilding distances.

Telecommunications Closet: See Closet, Telecommunications.

Telecommunications Entrance Facility: See Entrance Facility, Telecommunications.

Telecommunications Entrance Point: See Entrance Point, Telecommunications.

Telecommunications Entrance Room or Space: See Entrance Room or Space, Telecommunications.

Telecommunications Equipment Room: See Equipment Room, Telecommunications.

Telecommunications Grounding Busbar: A common point of connection for telecommunications system and bonding to ground, which is located in the telecommunications closet or equipment room.

Telecommunications Infrastructure: See Infrastructure, Telecommunications.

Telecommunications Outlet/Connector: See Outlet/Connector, Telecommunications.

Telemetry Cable: Cable used for transmission of information from instruments to the peripheral recording equipment.

Temperature Rating: The maximum temperature at which an insulating material may be used in continuous operation without loss of its basic properties.

Tensile Strength: The pull stress required to break a given specimen.

Tension Member: A member included in a fiber cable to add tensile strength.

Terminal: (1) A point at which information may enter or leave a communications network; (2) the input-output associated equipment; or (3) a device by means of which wires may be connected to each other.

Termination Hardware: This term is outmoded. See Connecting Hardware.

Test Lead: A flexible, insulated lead wire used for making tests, connecting instruments to a circuit temporarily or for making temporary electrical connections.

Textile Braid: Any braid made from threads of cotton silk, or synthetic fibers.

Thermal Aging: Exposure to a thermal condition or programmed series of conditions for predescribed periods of time.

Thermocouple Lead Wire: An insulated pair of wires used from the couple to a junction box.

Thermoplastic: A material which softens when heated and becomes firm on cooling.

Thermoset: A material which hardens or sets when heat is applied, and which, once set, cannot be resoftened by heating. The application of heat is called “curing.”

Three-Phase Current: Current delivered through three wires, with each wire serving as a return for the other two.

Three-Phase Three-Wire System: An alternating current supply system comprising three conductors over which three-phase power is sent.

Three-Wire System: A d-c or single-phase a-c system comprising three conductors, one of which is maintained at a potential midway between the potential of the other two.

Tin Overcoat (TOC): Tinned copper wire, stranded, then coated with pure tin.

Glossary

Page 226: Cross-Reference & Online Spec Sheets - Datasheet Archive

215

Technical Information Electronics

Tinsel Wire: A low-voltage stranded wire, with each strand a very thin conductor ribbon spirally wrapped around a textile yarn.

Topcoat: Bare (untinned) copper wire, stranded then coated with pure tin.

Topology: The physical or logical arrangement of a telecommunications system.

Tracer: A means of identifying polarity.Transducer: A device for converting mechanical

energy to electrical energy.Transfer Impedance: The ratio of the source

voltage of the wires inside the cable to the shield current of the cable or connectorized cable assembly.

Transition Point: A location in the horizontal cabling where flat undercarpet cable connects to round cable.

Transmission: Transfer of electric energy from one location to another through conductors or by radiation or induction fields.

Transmission Cable: Two or more transmission lines. See Transmission Line.

Transmission Line: An arrangement of two or more conductors or a wave guide used to transfer signal energy from one location to another.

Transmission Loss: The decrease or loss in power during transmission of energy from one point to another. Usually expressed in decibels.

Transmission Media: The various types of wire and optical fiber cable used for transmitting voice or data signals. Typically, wire cable includes twisted pair, coaxial and twinaxial. Optical fiber cable includes single, dual, quad, stranded and ribbon (Al).

Transmitter: The electronic package that injects an electrical signal or light signal over the transmission medium.

Transparent: (fiber optic) Transmitting rays of light so that objects can be seen through the material.

Transposition: Interchanging the relative positions of wires to neutralize the effects of induction to or from other circuits or, to minimize interference pickup by the lead-in during reception.

Tray Cable: A factory-assembled multiconductor or multipair control cable approved under the National Electrical Code for installation in trays.

Triaxial: A three-conductor cable with one conductor in the center, a second circular conductor shield concentric with the first, and third circular conductor shield insulated from and concentric with the first and second, usually with insulation, and over a braid or impervious sheath overall.

Triboelectric Noise: Noise generated in a shielded cable due to variations in capacitance between shielding and conductor as the cable is flexed.

Triple Cable: A cable composed of three insulated single conductors and one bare conductor, all twisted together. It may or may not have a common covering of binding.

True Concentric: A cable in which each successive layer has a reversed direction of lay from the preceding layer.

Trunk Cable: See Feeder Cable.Tubing: A tube of extruded non-supported plastic

material.

Twin Cable: A pair of insulated conductors twisted, sheathed or held together mechanically and not identifiable from each other in a common covering.

Twin Coaxial: A configuration containing two separate, complete coaxial cables laid parallel or twisted around each other in one complex.

Twin Line: A transmission line which has a solid insulating material, in which the two conductors are placed in parallel to each other.

Twinner: A device for twisting together two conductors.

Twisted Pairs: A cable composed of two small insulated conductors twisted together without a common covering.

Unbalanced Line: A transmission line in which voltages on the two conductors are unequal with respect to ground.

Unidirectional Concentric Stranding: A stranding where each successive layer has a different lay length, thereby retaining a circular form without migration of strands from one layer to another.

Unidirectional Stranding: A term denoting that in a stranded conductor, all layers have the same direction of lay.

Unilay Strand: A conductor constructed with a central core surrounded by more than one layer of helically-laid wires, with all layers having a common length and direction of lay.

Velocity of Propagation (VP): The speed of an electrical signal down a length of cable compared to speed in free space expressed as a percent. It is the reciprocal of the square root of the dielectric constant of the cable insulation.

Volt: A unit of electromotive force.Voltage: The term most often used in place of

electromotive force, potential difference or voltage drop to designate the electric pressure that exists between two points and is capable of producing a current when a closed circuit is connected between two points.

Voltage Drop: The voltage developed across a component or conductor by the current in the resistance or impedance of the component or conductor.

Voltage Rating: The highest voltage that may be continuously applied to a wire in conformance with standards or specifications.

Voltage Standing Wave Ratio (VSWR): The ratio of the maximum effective voltage to the minimum effective voltage measured along the length of a mis-matched radio frequency transmission line.

Volume Resistivity (Specific Insulation Resistance): The electrical resistance between opposite faces of a 1 cm. cube of insulating material, commonly expressed in Ω/centimeter.

Vulcanization: A chemical reaction in which the physical properties of an elastomer are changed by reacting it with sulfur or other cross-linking agents.

Wall Thickness: The thickness of the applied insulation or jacket.

Water Absorption: A test to determine the water absorbed by a material after a given immersion period.

Waterblocked Cable: A cable constructed with no internal voids in order to allow no longitudinal water passage under a given pressure.

Watt: A unit of electric power.Wave Form: A graphical representation of a

varying quantity. Usually, time is represented on the horizontal axis, and the current or voltage value is represented on the vertical axis.

Wave Length: The distance, measured in the direction of propagation, of a repetitive electrical pulse or waveform between two successive points that are characterized by the same phase of vibration.

Wicking: The longitudinal flow of a liquid in a wire or cable due to capillary action.

Wire: A conductor, either bare or insulated.Wire and Cable Marker: Device for identification

marking of wire and cable.Wire and Cable Tying, Clamping, and

Harnessing Devices: Tying tapes, lacing cords and flexible sleevings which are used for wire and cable bundling, harnessing and holding. Other devices include plastic ties or clamps, spiral-cut plastic tubing and plastic U-shaped trays or ducts.

Wire and Lead Cutters: Tools for cutting that range from plier-type cutters to semiautomatic or fully automatic machines integrated with other wire processing operations such as stripping, forming and terminating.

Wire Gauge: A system of numerical designation of wire sizes.

Wire Nut: A closed-end splice that is screwed on instead of crimped.

Wire Wrapped Connection: A solderless connection made by wrapping bare wire around a square or rectangular terminal with a power or hand tool.

Wire Wrapping Tools: Portable electric tools and automatic stationary machines used to make solderless wrapped connections of wires to terminals.

Wiring Closet: See Telecommunications Closet.Work Area (Work Station): A building

space where the occupants interact with telecommunications terminal equipment.

Wrapper: An insulating barrier applied as a sheet or tape wrapped around a coil periphery.

Yield Strength: The minimum stress at which a material will start to physically deform without increase in load.

Zytel®: DuPont’s trade name for nylon resins.

Sections of this glossary are reprinted with permission from December, 1985 Issue of ELECTRONICS copyright 1985. Lake Publishing Corporation, 17730 W. Peterson Rd., Libertyville, IL 60048-0159 USA. Permission to reprint granted to the General Cable Corporation. No additional reproduction of this wire and cable glossary allowed without written permission.

Glossary

Page 227: Cross-Reference & Online Spec Sheets - Datasheet Archive

216

Electronics Technical Information

A-D: Analog to digital conversionac: Alternating currentAC: Armored Cable, NEC Article 333 Cable

DesignationAC0: Analog Central OfficeACR: Attenuation to Crosstalk RatioADO: Auxiliary Disconnect OutletAER: AerialAF: Audio frequencyAIA: American Institute of ArchitectsALPETH: An aerial telephone cable having an alu-

minum shield and polyethylene jacketALS: A type of cable consisting of insulated con-

ductors enclosed in a continuous, closely fitting aluminum tube

ALVYN: An indoor, riser rated telephone cable hav-ing an aluminum shield and vinyl jacket (PVC)

AM: Amplitude ModulationANSI: American National Standards InstituteARPANET: Advanced Research Projects Agency

NetworkASCII: American Standard Code for Information

InterchangeASME: American Society of Mechanical EngineersASP: A filled, direct burial telephone cable used in

areas subject to rodent attack. It consists of a filled cable core, corrugated aluminum shield, corrugated steel tape, flooding compound and polyethylene jacket.

ASTA: United Kingdom approval agencyASTM: American Society for Testing and MaterialsAWG: American Wire GaugeAWM: Appliance wiring materialB & S Gauge: See American Wire Gauge (AWG)B or BUR: BuriedAWM: Appliance wiring materialBCF: Billion Conductor FeetBEF: Building Entrance FacilityBER: Bit Error RateBIC: Building Industry ConsultantBICSI: Building Industry Consulting Service

InternationalBISDN: Broadband Integrated Services Digital

NetworkBTU: British Thermal UnitCA: CableCATV: (1) Community Antenna Television; Cable

Access Television (2) CATV Cable, NEC Article 820 Cable Designation

CATVP: CATV Plenum Cable, NEC Article 820 Cable Designation

CATVR: CATV Riser Cable, NEC Article 820 Cable Designation

CATVX: CATV Limited Use Cable, NEC Article 820 Cable Designation

CB: Citizens bandC-C: Conductor to conductor capacitanceCCITT: The International Telegraph and Telephone

Consultative CommitteeCCTV: Closed-circuit televisionCDDI: Copper Distributed Data InterfaceCDF: Central Distribution FrameCDO: Community Dial OfficeCEBEC: Belgium approval agency; Commite

Electrotechnique Belge Service de la MarqueCEE: European standards agency; International

Commission on Rules for the Approval of Electrical Equipment

CEN: European Committee for StandardizationCENELEC: European Committee for

Electrotechnical StandardizationCFC: Communications Flat Cableckt: CircuitCLT or CLOS: ClosetCL2: Class 2 Circuit Cable, NEC Article 725 Cable

DesignationCL2P: Class 2 Circuit Plenum Cable, NEC Article

725 Cable DesignationCL2R: Class 2 Circuit Riser Cable, NEC Article 725

Cable DesignationCL2X: Class 2 Circuit Limited Use Cable, NEC

Article 725 Cable DesignationCL3: Class 3 Circuit Cable, NEC Article 725 Cable

DesignationCL3P: Class 3 Circuit Plenum Cable, NEC Article

725 Cable DesignationCL3R: Class 3 Circuit Riser Cable, NEC Article 725

Cable DesignationCL3X: Class 3 Circuit Limited Use Cable, NEC

Article 725 Cable DesignationCM: Communications Cable, NEC Article 800 Cable

DesignationCMA: Circular Mil AreaCMP: Communication Cable Plenum, NEC Article

800 Cable DesignationCMR: Communications Cable Riser, NEC Article

800 Cable DesignationCMX: Communications Limited Use Cable, NEC

Article 800 Cable DesignationCO: Central Officecodec: Coder decoderCOE: Central Office EquipmentCOS: Cooperation for Open SystemsCOSINE: Cooperation for Open Systems

Interconnection Network in EuropeCOT: Central Office TerminalCPC: Customer Premises CommunicationCPE: (1) Chlorinated Polyethylene (2) Customer

Premises Equipment or Customer Provided Equipment

CPU: Central Processing UnitCRT: Cathode Ray TubeCSMA/CD: Carrier Sense Multiple Access/

Collision DetectionCSPE: Chlorosulfonated PolyethyleneCTR: Certified Test ReportCV: Continuous vulcanizationD-A: Digital to analog conversionDAF: Dedicated Access FacilitydB: DecibelDBS: Direct Broadcast Satellitedc: Direct currentDCE: Data Circuit-Terminating EquipmentDCO: Digital Central OfficeDCR: Direct Current ResistanceDD: Distribution Designer or Distribution DeviceDEMARC: Demarcation pointDEMKO: Approval agency of DenmarkDGM: Data Grade MediumDISA: Defense Information Systems Agency

(formerly DCA)DISI: Directory Information Services InfrastructureDIST: DistrictDRT: Plastic range and dryer cord (CSA)DTE: Data Terminal EquipmentDVD: Digital Versatile DiscDW: Distribution Wire

E: Symbol for voltage. Usually used to represent direct voltage or the effective (root-mean-square) value of an alternating voltage

EFTS: Electronic funds transfer systemEIA: Electronic Industries AssociationEMF: Electromotive ForceEMI: Electromagnetic InterferenceEMT: Electric Metallic TubingEP: Entrance pointEPDM: Ethylene-propylene-diene monomer rubberEPOS: Electronic Point-Of-SaleEPR: Ethylene-propylene rubberER: Equipment roomESS: Electronic Switching SystemESTA: Australian approval agency; Electricity Trust

of South AustraliaETPC: Electrolytic Tough Pitch CopperETV: Educational TelevisionE/W: Equipped WithEX or EXT: ExtensionEXCH: Exchangef: FrequencyFAA: Federal Aeronautics AdministrationFCC: (1) Federal Communications Commission (2)

Flat Conductor Cable, NEC Article 328 Cable Designation

FDDI: Fiber Distributed Data InterfaceFDM: Frequency-Division MultiplexingFDR: FeederFEP: Fluorinated ethylene propyleneFEXT: Far End CrosstalkFI: Approval agency of Finland; Electrical

InspectorateFIPS PUB: Federal Information Processing

Standard PublicationFM: Frequency modulationFOCIS: Fiber Optic Connector Intermateability

StandardFOTP: Fiber Optic Test ProcedureFOTS: Fiber Optics Transmission SystemFPL: Power Limited Fire Protective Signaling Circuit

Cable, NEC Article 760 Cable DesignationFPLP: Power Limited Fire Protective Signaling

Circuit Plenum Cable, NEC Article 760 Cable Designation

FPLR: Power Limited Fire Protective Signaling Circuit Riser Cable, NEC Article 760 Cable Designation

FR-1: A flammability rating established by Underwriter's Laboratories for wires and cables that pass a specially designed vertical flame test

freq: FrequencyFRICC: Federal Research Internet Coordinating

Committee (now FNC)FRPE: Flame Retardant Polyethyleneft: FootFTP: Fire Transfer Protocolga: GaugegHZ: Gigahertzgrd: GroundGTO: Gas tube sign and oil-burner ignition cable.

5,000V-15,000V.H: Designation for intensity of magnetic energyhc: Handset combination (single-line telephone)HC: Horizontal cross-connecthck: Handset combination; key (six-button

telephone)HDPE: High Density PolyethyleneHF: High Frequency

Abbreviations & Acronyms

Page 228: Cross-Reference & Online Spec Sheets - Datasheet Archive

217

Technical Information Electronics

hh: HandholeHi-Pot: A test designed to determine the highest

voltage that can be applied to a conductor without breaking through the insulation.

HPD: Rubber- and asbestos-insulated heater cord. No braid on individual conductors but with braid overall. Also made with neoprene insulation and no asbestos or PVC/NBC.

HPN: Two-conductor, neoprene-insulated heater cord. Parallel construction. For use in damp locations.

HSJ: Same as type HS but with #18, #16 and #14 conductors and differing thickness of jacket.

HVAC: Heating, ventilation and air conditioningHz: Hertzi: Symbol used to designate currentIC: Intermediate cross-connectICEA: Insulated Cable Engineers AssociationIDC: Insulation Displacement ConnectorIEC: Internation Electrotechnical CommissionIEEE: Institute of Electrical and Electronics

EngineersIGS: Integrated Gas Spacer Cable, NEC Article

325 Cable DesignationIMSA: International Municipal Signal Associationin: InchIRSG: Internet Research Steering GroupIRTF: Internet Research Task ForceIS: International StandardISA: Instrument Society of AmericaISDN: Integrated Services Digital NetworkISO: International Organization for StandardizationISOC: Internet SocietyITCO: Independent Telephone CompanyITU-T: International Telecommunications Union -

Telecommunications Standardization SectionIW (C): Inside Wiring (cable)J: Joulekcmil: One thousand circular milsKEMA KEUR: Approval agency of the Netherlandskft: An abbreviation for 1000 ft.kHz: KilohertzKilo: A numerical prefix denoting 1000 (103)km: KilometerKTS: Key Telephone ServicekV: KilovoltkVA: Kilovolt AmperekW: KilowattLAN: Local Area NetworkLASER: Light Amplification by Stimulated

Emission of RadiationLATA: Local Access Transport Arealbf: Pound forceLBO: Line BuildoutLDPE: Low Density PolyethyleneLEC: Local Exchange CarrierLED: Light-Emitting DiodeLLDPE: Linear Low Density PolyethyleneLOCA: Loss of Coolant Accidentlocap: Low-capacitance, low-loss paired cableMAC: Moves, Adds and ChangesMAP: Manufacturing Automation ProtocolMATV: Master Antenna TelevisionMbps: Megabits per secondMC: (1) main cross-connect (2) Metal Clad Cable,

NEC Article 334 Cable DesignationMCM: One thousand circular milsMDF: Main Distribution Frame

MDPE: Medium Density PolyethyleneMeg or Mega: A numerical prefix denoting

1,000,000 (106)M/G: Motor/Generator SetMH: ManholeMho: The unit of conductivity. The reciprocal of an

ohm.MHz: MegahertzMI: Mineral Insulated Cable, NEC Article 330

Cable DesignationMicro: A numerical prefix denoting one-millionth

(106)MIL STD: Military StandardMILNET: Military NetworkMLT: Multi-Level Thresholdmm: MillimeterModem: Modulator demodulatorMTT: Main Telephone TerminalMTW: Machine Tool WireMV: Medium Voltage Cable, NEC Article 326

Cable DesignationMW: Radio hookup wire with polyvinyl insulation

and plain or nylon jacket or braid, or shield, 1000V

N: NewtonNAIC: Network Applications and Information

CenterNASA: National Aeronautics and Space

AdministrationNBR: Natural butadiene-acrylonitrile copolymer

rubberNBS: National Bureau of Standards (now NIST)NEC: National Electrical CodeNEMA: National Electrical Manufacturers

AssociationNEMKO: Approval agency of NorwayNESC: National Electrical Safety CodeNEXT: Near End Crosstalknf: NanofaradNFPA: National Fire Protection AssociationNI: Network InterfaceNID: Network Interface DeviceNIST: National Institute of Standards and

Technology (formerly NBS)NIU: Network Interface Unitnm: NanometerNM & NMC: Non Metallic Sheathed Cable, NEC

Article 336 Cable DesignationNPLF: Non Power-Limited Fire Protective

Signaling Circuit Cable, NEC Article 760 Cable Designation

NPLFP: Non Power-Limited Fire Protective Signaling Circuit Plenum Cable, NEC Article 760 Cable Designation

NPLFR: Non Power-Limited Fire Protective Signaling Circuit Plenum Cable, NEC Article 760 Cable Designation

NRZ: Non Return to ZeroNRZI: Non Return to Zero InvertedOC: Optical CarrierODC: Ozone Depleting ChemicalOP: Outside PlantOPE: Outside Plant EngineerOSHA: Occupational Safety and Health

AdministrationOSI: Open Systems InterconnectionOVE: Approval agency of West Germany;

Oesterreichischer Verband fur Elektrotechnik

PABX: Private Automatic Branch ExchangePAM: Pulse Amplitude ModulationPAP: A commonly used term for air core (unfilled)

direct burial telephone cable with a corrugated aluminum shield

PBX: Private Branch ExchangePC: Personal ComputerPCB: Printed Circuit BoardP-FEP: General Cable proprietary dielectric

material used injunction with FEP.PCM: Pulse Code ModulationPCP: A commonly used term for air core (unfilled)

direct burial cable with a corrugated copper shield

PE: Polyethylenepf: PicofaradPFA: PolyfluoroalkoxyPIC: A general term for any type of plastic

insulated telephone cablePico: A numerical prefix denoting one-millionth of

one-millionth (10-12)PL: Private LinesPLSJ: All-rubber, parallel-jacketed, two-

conductor, light-duty cord for pendant or portable use in damp locations. 300V.

PLT: (1) Plant (2) Same as PLSJ except thermo- plastic insulation

PLTC: Power Limited Tray Cable, NEC Article 725 Cable Designation

PM: Phase ModulationPOI: Point Of InterfacePOSJ: All-rubber, parallel, light duty rip-cord for

use on lamps and small appliances, 300V, 60°CPOT: Thermoplastic, parallel, light duty rip-cord.

300V, 60°C to 105°C.POTS: Plain Old Telephone Service (colloquial)PP: PolypropylenePR: PairPTFE: PolytetrafluoroethylenePTSS: Passive Transmission Sub-SystemPVC: Polyvinyl ChloridePVDF: Polyvinylidene FluorideR: Symbol for resistanceR-F: Radio-frequencyRCDD: Registered Communication Distribution

DesignerREA: Rural Electrification AdministrationREP: RepairRFQ: Request for QuoteRG/U: General utility grade military coaxial cableRH: Relative humidityRJ-45: A specific pin-point assignment for an eight

position modular telecommunications connector.

RMS: (1) rack mount space (2) Root Mean Squares

RoHS: Restriction on Hazardous SubstancesS: Heavy-duty, rubber-insulated portable cord.

Stranded copper conductors with separator and individual rubber insulation. Two or more color- coded conductors cabled with filler, wrapped with separator and rubber jacketed overall, 600 Volts.

SAE: Society of Automotive EngineersSANZ: Standards Association of New ZealandSBR: Styrene Butadiene RubberScTP: Screened Twisted PairSDN: Switched Digital Network

Abbreviations & Acronyms

Page 229: Cross-Reference & Online Spec Sheets - Datasheet Archive

218

Electronics Technical Information

SE: Service Entrance Cable, NEC Article 338 Cable Designation

SEMKO: Approval agency for SwedenSFTP: Simple File Transfer ProtocolSI: System InternationaleSJ: Junior hard-service, rubber-insulated pendant or

portable cord. Same construction as type S, but 300V. Jacket thickness different.

SJO: Same as SJ, but carolprene, oil-resistant com-pound outer jacket. Can also be made "water-resistant." 300V, 60°C.

SJT: Junior hard service thermoplastic or rubber-insulated conductors with overall thermoplastic jacket, 300V, 60°C to 105°C.

SJTO: Same as SJT but oil-resistant thermo- plastic outer jacket. 60°C.

SMTP: Simple Mail Transfer ProtocolSNA: Systems Network ArchitectureSNM: Shielded Non Metallic Sheathed Cable, NEC

Article 337 Cable DesignationSNMP: Simple Network Management ProtocolSNR: Signal to Noise RatioSO: Hard-service cord, same construction as type

S except oil-resistant carolprene jacket, 600V, 60° to 90°C.

SONET: Synchronous Optical NetworkSP-1: All rubber, parallel-jacketed, two-conductor

light-duty cord for pendant or portable use in damp locations. 300V.

SP-2: Same as SP-1, but heavier construction, with or without third conductor for grounding purposes. 300V.

SP-3: Same as SP-23, but heavier construction for refrigerators or room air conditioners. 300V.

SPC: Stored Program ControlSPG: Single Point GroundSPT-1: Same as SP-1, except all-thermoplastic.

300V. With or without third conductor for grounding.

SPT-2: Same as SP-2, except all-thermoplastic. 300V. With or without third conductor for grounding.

SPT-3: Same as SP-3, except all-thermoplastic. 300V. With or without third conductor for grounding.

SRD: Portable range or dryer cable. Three or four rubber-insulated conductors with rubber or neoprene jacket, flat or round construction. 300V, 60°C.

SRDT: Same as SRD, except all-thermoplastic with a maximum temperature of 90°C.

SRL: Structural return lossST: Hard-service cord, jacketed, same as type S

except all-plastic construction, 600V, 60°C to 105°C.

STA: StationSTO: Same as ST but with oil-resistant thermo-

plastic outer jacket. 600V, 60°C.STP: Shielded twisted pairSV: Vacuum cleaner cord, two or three-conductor,

rubber-insulated. Overall rubber jacket. For light- duty in damp locations. 300V, 60°C.

SVO: Same as SV except carolprene jacket, 300V, 60°C.

SVT: Same as SV except all-plastic construction. With or without third conductor for grounding purposes only. 300V, 60°C to 90°C.

SW: Station WireSWB: Switchboard

SWR: Standing Wave RatioSYS: SystemTC: (1) Power and Control Tray Cable, NEC Article

340 Cable Designation (2) Telecommunications Closet

TCP: Transmission Control ProtocolTDM: Time-Division MultiplexingTEL: TelephoneTELCO: Telephone CompanyTERM: Terminal or terminationTEW: Canadian Standard Association type

appliance wires. Solid or stranded single conductor, plastic-insulated, 600V, 105°C.

TF: Fixture wire, thermoplastic-covered solid or seven strands. 60°C.

TFE: TetrafluoroethyleneTFF: Same as TF but flexible stranding. 60°C.THHN: 90°C, 600V nylon jacketed building wireTHW: Thermoplastic vinyl-insulated building wire.

Flame-retardant, moisture- and heat-resistant. 75°C. Dry and wet locations.

THWN: Same as THW but with nylon jacket overall. 75°C.

TIA: Telecommunications Industry AssociationTOC: Tin OvercoatTP: Transport ProtocolTP-PMD: Twisted Pair-Physical Medium DependentTPDDI: Twisted Pair Distributed Data InterfaceTSB: Telecommunications System BulletinTT: Telephone TerminalTTB: Telephone Terminal BoardTTY: Text TelephonesTW: Thermoplastic vinyl-jacketed building wire,

moisture-resistant. 60°C.UCC: Uniform Code CouncilUF: Thermoplastic underground feeder and

branch circuit cableUF: Underground Feeder and Branch Circuit

Cable, NEC Article 339 Cable DesignationUG: UndergroundUHF: Ultra High Frequency, 300 to 3,000 MHzUL: Underwriter's Laboratories, Inc.µm: Micron or micrometerUPC: Universal Packaging CodeUPS: Uninterruptible Power SupplyUSE: Underground Service Entrance Cable, NEC

Article 338 Cable DesignationUTE: Approval agency for France; Union

Technique de l'ElectriciteUTP: Unshielded twisted-pairV: VoltVDE: West Germany approval agencyVHF: Very High Frequency, 30 to 300 MHzVP: Velocity of PropagationVSWR: Volume Standing Wave RadioVW-1: A flammability rating established by

Underwriters Laboratories for wires and cables that pass a specially designed vertical flame test, (formerly designated FR-1)

W: Symbol for watt or wattageWA: Work areaWP: Waterproof OutletX: Cross-connectXLPE: Crosslinked polyethyleneZ: Symbol for impedance

Abbreviations & Acronyms

Page 230: Cross-Reference & Online Spec Sheets - Datasheet Archive

219

Technical Information Electronics

TEMP. °C VOLTAGE UL UL CSA MIL AWG P/N STRAND TYPE PAGE

60 60 60 60 60

1500* 3000* 5000* 5000* 10000*

— — — — —

— — — — —

— — — — —

— — — — —

20 20 18 18 18

C1326 C1319

C1320A C1321 C1318

STRANDED STRANDED STRANDED STRANDED STRANDED

7 7 7 7 7

80 80 80 80 80 8080

1000 1000 1000 1000 1000 1000 1000

— — — — — — —

— — — — — — —

— — — — — — —

W-76B W-76B W-76B W-76B W-76B W-76B W-76B

24 22 20 18 16 14 12

C7600A C7602A C7604A C7606A C7608A C7610A C7611A

STRANDED STRANDED STRANDED STRANDED STRANDED STRANDED STRANDED

4 4 4 4 4 4 4

80/105 80/105 80/105 80/105 80/105 80/105 80/105 80/105 80/105 80/105

300 300 300 300 300 300 300 300 300 300

1007 1007 1007 1007 1007 1007 1007 1007 1007 1007

1569 1569 1569 1569 1569 1569 1569 1569 1569 1569

TR-64 TR-64 TR-64 TR-64 TR-64 TR-64 TR-64 TR-64 TR-64 TR-64

— — — — — — — — — —

24 24 22 22 20 20 18 18 16 16

C2003A C2015A C2004A C2016A C2028A C2040A C2052A C2064A C2053A C2065A

SOLID STRANDED

SOLID STRANDED

SOLID STRANDED

SOLID STRANDED

SOLID STRANDED

2 2 2 2 2 2 2 2 2 2

105 105 105 105 105 105 105 105 105 105 105

600 600 600 600 600 600 600 600 600 600 600

1015 1015 1015 1015 1015 1015 1015 1015 1015 1015 1015

— — — — — — — — — — —

TEW TEW TEW TEW TEW TEW TEW TEW TEW TEW TEW

— — — — — — — — — — —

24 22 22 20 20 18 18 16 14 12 10

C2100A C2101A C2117A C2102A C2118A C2103A C2119A C2104A C2105A C2106A C2107A

STRANDED STRANDED

SOLID STRANDED

SOLID STRANDED

SOLID STRANDED STRANDED STRANDED STRANDED

3 3 3 3 3 3 3 3 3 3 3

* For intermittent duty only

Hook-Up Wire Product Finder

Page 231: Cross-Reference & Online Spec Sheets - Datasheet Archive

220

Electronics Technical Information

B - BRAID SHIELD IFB - INDIVIDUAL FLEXFOIL® + FLEXFOIL® /BRAID UJ - UN-JACKETED C - CAROLPRENE® P - PLENUM

F - FLEXFOIL® SHIELD R - RUBBER FB - FLEXFOIL® /BRAID SHIELD S - SPIRAL SHIELD I - INDIVIDUAL FLEXFOIL® SHIELD U - NO SHIELD

NO. COND.

STRAND TYPE

AWG 28 AWG 24 AWG 22 AWG 20 AWG 19 AWG 18 AWG 16 AWG 14 AWG 12P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE

1 SOLID

STRANDED 743605 B ............169 743601 B ............169743602 B ............169743603 B ............169743604 B ............169C1300 B,R ...........172

C1201 B,C ...........175 C1301 B,R ...........172

2 SOLID C2515A F ..............23 C2676A B ..............34 C4008A U ..........9, 43 C4167A F ..............29 C4408 U ..............138 E1000S U ............134 E1482S U ............117 E2000S F .............135 E2100S F-P .........137 E2482S S ............119 E3000S U-P .........136 E3482S U-P .........121 E3542S F-P .........123

C2509A F ............164 C4311A C ................9

C2754A ...................9 C0471 U ..............125 C0472 F ..............126 C3060 F-P .............28 C3110 U-P .............17 C3167 F-P ...........128 C3200 U-P ...........122 C3240 U-P ...........127 C3260 F-P ...........124 C4304A U ............118C4334A F ............120E1030S U ............134 E1502S U ............117 E2030S F .............135 E2200S F-P .........137 E2402S U ............117 E2502S F .............119 E3030S U-P .........136 E3502S U-P .........121 E3602S F-P .........123

C0473 U ..............125 C0474 F ..............126 C3168 F-P ...........128 C3210 U-P ...........122 C3241 U-P ...........127 C3270 F-P ...........124 C4321A U ............118C4344A F ............120E1512S U ............117 E2404S U ............117 E2522S F .............119 E3512S U-P .........121 E3612S F-P .........123

C0475 U ..............126 C0491 U ..............125 C3172 F-P ...........128 C3220 U-P ...........122 C3224 U-P ...........122 C3244 U-P ...........127 C3280 F-P ...........124 C4163A F ..............29 C4324A U ............118C4347A F ............120E1522S U ............117 E2406S U ............117 E2532S F .............119 E3522S U-P .........121 E3622S F-P .........123

C0476 F ..............126 C0492 U ..............125 C3174 F-P ...........128 C3224 U-P ...........122 C3246 U-P ...........127 C3282 F-P ...........124 C4164A F ..............29 C4327A U ............118C4348A F ............120E1532S U ............117 E2542S F .............119 E3532S U-P .........121 E3632S F-P .........123

2 STRANDED C6500A B ..............37 743701 B ............170743704 B ............170743705 B ............170C0740A F ..............68 C1226A S ............173 C1228A F ............172 C1356 U ..............156 C2461A U ..............11 C2513A F ..............23 C4152A F ..............29 C4216A F ..............31

743706 B ............170C0431A U ..............22 C0450A F ..............32 C0760A F ..............69 C1322A B ............174 C1362 U ..............156 C2514A F ..............23 C2516A F ..............23 C2518A F ..............24 C2520A F ..............24 C2677A B ..............34 C2679A B ..............36 C2882A S ..............33 C3105 U-P .............16 C3115 U-P .............17 C3154 F-P .............27 C3158 F-P .............28 C4100A U ..............18 C4153A F ..............29 C4168A F ..............29 C4192A F ..............30 C4210A F ..............30 C6310 UJ ............138 C6348A U ..............12 E1002S U ............134 E2002S F .............135 E2102S F-P .........137 E3002S U-P .........136

743707B .............170C0433A U ..............22 C0452A F ..............32 C1302 B,R .....40, 172 C1360 U ..............156 C1642A B ..............35 C2519A F ..............24 C2524A F ..............23 C2540A F ..............23 C2681A B ..............36 C2888A S ..............33 C3320 F-P .............27 C3602 U-R.............21 C4117A U ..............19 C4154A F ..............29 C4166A F ..............30 C4211A F ..............30 C6311 UJ ............138 C6351A U ..............13 E1022S U ............134 E2022S F .............135 E2122S F-P .........137 E3022S U-P .........136

740302 U ............158C0435A U ..............22 C0454A F ..............32 C1202 B,C .....41, 175 C1357 U ..............156 C2521A F ..............24 C2534A F ..............23 C2686A B ..............23 C2830A U ..............13 C2892A S ..............33 C3062 F-P .............28 C3102 U-P .............16 C3112 U-P .............17 C3162 F-P .............27 C4114A U ..............18 C4125A U ..............19 C4155A F ..............29 C4197A F ..............30 C4212A F ..............30 C5460 U ..............139 C6312 UJ ............138 C6367 U ..............157 C7102A UJ ..........156 C8116 U-P .............45C8122 U-P .............45E1032S U ............134 E2032S F .............135 E2202S F-P .........137 E3032S U-P .........136

740202 U ...........158C0437A U ..............22 C0456A F ..............32 C1358 U ..............158 C1602 B,C .....41, 175 C1704 U ..............152 C2405A U ..............14 C2536A F ..............17 C2895A S ..............33 C3068 F-P .............28 C3127 U-P .............17 C3169 F-P .............27 C3193 U-P .............16 C4135A U ..............20 C4162A F ..............29 C4213A F ..............30 C8111 FB-P ...........39E1042S U ............134 E2042S F .............135 E2242S F-P .........137 E3042S U-P .........136

740102 U ............158C0439A U ..............22 C0458A F ..............32 C1361 U ..............156 C1612 B,C .............41 C1702 U ..............152 C2409A U ..............14 C2538A F ..............17 C3126 U-P .............16 C4146 U-P .............20 C4201A F ..............30 C4215A F ..............30 E1052S U ............134 E2052S F .............135 E2252S F-P .........137 E3052S U-P .........136

740002 U ............158C0441A U ..............22 C0460A F ..............32 C1363 U ..............156 C1364 U ..............157 C1700 U ..............152 C2410A U ..............14 C2539A F ..............17 C3129 U ................17 C4150A U ..............20 C4202A F ..............30 E1062S U ............134 E2062S F .............135 E2262S F-P .........137 E3062S U-P .........136

3 SOLID C4410 U ..............138 C2510A F ............164 C1201 B,C ...........175 C1301 B,R ...........172 C3114 U-P .............17C4305A U ............118C4335A F ............120E1503S U ............117 E2503S S ............119 E3503S U-P .........121 E3603S F-P .........123

C4322A U ............118C4345A F ............120

C4325A U ............118

STRANDED C0530A FB ............72 C0939A FB ............70 C6501A B ..............37

C0680A FB ............72 C0741A F ..............68 C0951A FB ............70 C2462A U ..............11 C4217A F ..............31C8115 FB-P ...........39

C0432A U ..............22 C0451A F ..............32 C0761A F ..............69 C0971A FB ............71 C1335A S ..............33 C2517A F ..............23 C2526A F ..............23 C2678A B ..............36 C3310 F-P .............27 C4062A U ..............12 C4101A U ..............18 C4156A F ..............29 C4169A F ..............29 C4193A F ..............30 E1003S U ............154 E2003S F .............135 E2103S F-P .........137 E3003S U-P .........136

C0434A U ..............15 C0781A F ..............69 C1304 B,R .............40 C1332A B ..............36 C1333A F ............159 C1643A B ..............35 C2525A F ..............23 C2528A F ..............23 C3321 F-P .............28 C3603 U,R .............21 C4118A U ..............19 C4157A F ..............29 C4158A F ..............29 C6352A U ..............13 E1023S U ............134 E2023S F .............135 E2123S F-P .........137 E3023S U-P .........136

C0436A U ..............22 C0455A F ..............32 C1203 B,C .............41 C2535A F ..............23 C2768A S ..............33 C2831A U ..............13 C3064 F-P .............28 C3120 U-P .............17 C3164 F-P .............27 C3190 U-P .............16 C4126A U ..............19 C4159A F ..............29 C4198A F ..............30 C8106 F-P .............26C8107 FB-P ...........39E1033S U ............134 E2033S F .............135 E2203S F-P .........137 E3033S U-P .........136

C0438A U ..............22 C0457A F ..............32 C1603 B,C .............41 C2406A U ..............14 C2537A F ..............23 C3194 U-P .............16 C3340 F-P .............27 C4136A U ..............20 C4165A F ..............29 C4200A F ..............30 C8119 FB-P ...........39E1043S U ............134 E2043S F .............135 E2243S F-P .........137 E3043S U-P .........136

C0440A U ..............22 C0459A F ..............32

* For intermittent duty only

Multi-Conductor Cable Product Finder

Page 232: Cross-Reference & Online Spec Sheets - Datasheet Archive

221

Technical Information Electronics

B - BRAID SHIELD IFB - INDIVIDUAL FLEXFOIL® + FLEXFOIL® /BRAID UJ - UN-JACKETED C - CAROLPRENE® P - PLENUM

F - FLEXFOIL® SHIELD R - RUBBER FB - FLEXFOIL® /BRAID SHIELD S - SPIRAL SHIELD I - INDIVIDUAL FLEXFOIL® SHIELD U - NO SHIELD

NO. COND.

STRAND TYPE

AWG 28 AWG 24 AWG 22 AWG 20 AWG 19 AWG 18 AWG 16 AWG 14 AWG 12P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE

4 SOLID C4412 U ..............138E1001S U ............134E1484S U ............117E2484S F .............119E3001S U-P .........136

C0485 U ..............125C0494 F ..............126C3061 F-P .............28C3111 U-P .............17C3170 F-P ...........128C3201 U-P ...........122C3242 U-P ...........127C3261 F-P ...........124C4306A U ............118C4336A F ............120E1504S U ............117E2504S F .............119E3504S U-P .........121E3604S F-P .........123

C0486 U ..............125C3171 F-P ...........128C3211 U-P ...........122C3243 U-P ...........127C3271 F-P ...........124C4323A U ............118C4346A F ............120E1514S U ............117E2524S F .............119E3514S U-P .........121E3614S F-P .........123

C0496 F ..............126C3173 U-P ...........128C3223 U-P ...........122C3245 U-P ...........127C3284 F-P ...........124C4326A U ............118E1524S U ............117E2534S F .............119E3524S U-P .........121E3624S F-P .........123

C0497 F ..............126C3175 F-P ...........128C3225 U-P ...........122C3247 U-P ...........127C3283 F-P ...........124E1534S U ............117E2544S F .............119E3534S U-P .........121E3634S F-P ...........12

STRANDED C0531A FB ............72C0940A FB ............70C6502A B ..............37

C0681A FB ............72C0742A F ..............68C0952A FB ............70C2463A U ..............11C4218A F ................3

C0762A F ..............69C0972A FB ............71C1118 U ..............139C1337A S ..............33C1340A F ............160C2523A F ..............23C2680A B ..............36C3106 U-P .............16C3116 U-P .............17C3155 F-P .............27C3159 F-P .............28C4063A U ..............12C4102A U ..............18C4160A F ..............29C4194A F ..............30C5076 U ..............139E1004S U ............134E2004S F .............135E2104S F-P .........137E3004S U-P .........136

C0782A F ..............69C1119 U ..............139C1305 B,R .............40C1331A F ............160C1343A F ............160C1644A B ..............35C2555A F ..............23C2683A B ..............36C3322 F-P .............27C3604 U,R .............21C4119A U ..............19C4161A F ..............29C4196A F ..............30C5078 U ..............139C6353A U ..............13E1024S U ............134E2024S F .............135E2124S F-P .........137E3024S U-P .........136

740304 U ............158C0444A U ..............22C1123 U ..............139C1204 B,C .............41C2404A U ..............13C2543A F ..............25C2688A B ..............36C3063 F-P .............28C3103 U-P .............16C3113 U ................17C3163 F-P .............27C4127A U ..............19C4204A F ..............30C5084 U ..............139C8102 U-P .............15C8110 FB-P ...........39C8114 F-P .............26E1034S U ............134E2034S F .............135E2204S F-P .........137E3034S U-P .........136

740204 U ............158C1604 B,C .............41C1705 U ..............152C2425A U ..............14C3195 U-P .............16C3341 F-P .............27C4137A U ..............20E1044S U ............134E2044S F .............135E2244S F-P .........137E3044S U-P .........136

740104 U ............158C1614 B,C .............41C1703 U ..............152C2430A U ..............14C4147A U ..............20E1054S U ............134E2054S F .............135E2254S F-P .........137E3054S U-P .........136

740004 U ............158C1701 U ..............152C2440A U ..............14C4151A U ..............20E1064S U ............134E2064S F .............135E2264S F-P .........137E3064S U-P .........136

5 SOLID C3117 U-P .............17C4307A U ............118C4337A F ............120

C4349A U ............118C4350A F ............120

STRANDED C0532A FB ............72C0941A FB ............70

C0682A FB ............72C0753A F ..............68C0953A FB ............70C2464A U ..............11C4219A F ..............31

C0973A FB ............71C1124 U ..............139C4064A U ..............12C4103A U ..............18C5086 U ..............139

C1126 U ..............139C1308 B,R .............40C1645A B ..............35C3605 U,R .............21C4120A U ..............19C6355A U ..............13

C2420A U ..............13C4128A U ..............19

C2434A U ..............14C4138A U ..............20

C2437A U ..............14C4148A U ..............20

6 SOLID C4300A U ............118 C3118 U-P .............17 C4308A U ............118C4338A F ............120E1506S U ............117 E2506S F .............119 E3506S U-P .........121 E3606S F-P .........123

STRANDED C0533A FB ............72 C0942A FB ............70 C6503A B ..............37

C0683A FB ............72 C0743A F ..............68 C0954A FB ............70 C1345A F ............159 C2466A U ..............11 C4220A F ..............31

C0763A F ..............69 C0974A FB ............71 C1341A S ..............33 C3311A F-P ...........27 C4066 U ................12 C4104A U ..............18 C4207A F ..............30 E1006S U ............134 E2006S F .............135 E2106S F-P .........137 E3006S U-P .........136

C0783A F ..............69 C1310 B,R .............40 C1646A B ..............35 C3606 U,R .............21

C1206 B,C .............41 C3065 F-P .............28 C3121 U-P .............17 C3166 F-P .............27 C3192 U-P .............16 C4205A F ..............30 C4206A U ..............19 C8120 FB-P ...........39E1036S U ............134 E2036S F .............135 E2206S F-P .........137 E3036S U-P .........136

C1606 B,C .............41C8108 FB-P ...........39

7 SOLID C4309A U ............118C4339A F ............120

STRANDED C0534A FB ............72 C0943A FB ............70

C0684A FB ............72 C0754A F ..............68 C0955A FB ............70 C2488A U ..............11 C4221A F ..............31

C0975A FB ............71 C4088A U ..............12 C4105A U ..............18

C1312 B,R .............40 C3607 U,R .............21 C4121A U ..............19 C6356A U ..............13

C2421A U-P ...........13 C4129A U ..............19

C2426A U ..............14 C4139A U ..............20

C2431A U ..............14 C4149A U ..............20

8 SOLID C3119 F ................17 C4310A U ............118C4340A F ............120E1508S................117 E2508S................119

STRANDED C0535A FB ............72 C0944A FB ............70 C6504A B ..............37

C0685A FB ............72 C0744A F ..............68 C0956A FB ............70 C2465A U ..............11 C4222A F ..............31

C0764A F ..............69 C0976A FB ............71 C1130A U ............139 C4065A U ..............12 C4080 U ..............139 C4106A U ..............18 C4208A F ..............30 C5096 U ..............139 E1008S U ............134 E2008S F .............135 E2108S F-P .........137 E3008S U-P .........136

C0784A F ..............69 C1313 B,R .............40 C1648A FB ............38 C3608 U,R .............21 C4090 U ..............139

C1208 B,C .............41 C3122 U-P .............17 C3180 F-P .............27 C3191 U-P .............16 E1038S U ............134 E2038S F .............135 E2208S F-P .........137 E3038S U-P .........136

C1608 B,C .............41 C2443A U ..............14 C4140A U ..............20

Multi-Conductor Cable Product Finder

Page 233: Cross-Reference & Online Spec Sheets - Datasheet Archive

222

Electronics Technical Information

B - BRAID SHIELD IFB - INDIVIDUAL FLEXFOIL® + FLEXFOIL® /BRAID UJ - UN-JACKETED C - CAROLPRENE® P - PLENUM

F - FLEXFOIL® SHIELD R - RUBBER FB - FLEXFOIL® /BRAID SHIELD S - SPIRAL SHIELD I - INDIVIDUAL FLEXFOIL® SHIELD U - NO SHIELD

NO. COND.

STRAND TYPE

AWG 28 AWG 24 AWG 22 AWG 20 AWG 19 AWG 18 AWG 16 AWG 14 AWG 12P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE

9 SOLID C4312A U ............118C4341A F ............120

STRANDED C0536A FB ............72 C0945A FB ............70

C0686A FB ............72 C0755A F ..............68 C0957A FB ............70 C2470A U ..............11 C4223A F ..............31

C0977A FB ............71 C4070A U ..............12 C4107A U ..............18

C4122A U ..............19 C6357A U ..............13

C2422A U ..............13 C4130A U ..............19

C2435A U ..............14 C4141A U ..............20

10 SOLID C2511A F ............164 C4313A U ............118C4342A F ............120

STRANDED C0537A FB ............72 C0946A FB ............70 C6505A B ..............37

C0687A FB ............72 C0745A F ..............68 C0958A FB ............70 C2471A U ..............11

C0765A F ..............69 C0978A FB ............71 C4071A U ..............12 C4108A U ..............18 E1010S U ............134 E2010S F .............135

C0785A F ..............69 C3610 U,R .............21 C4123A U ..............19

C1210 B,C .............41 C3178 U-P .............16 C3181 F-P .............27E1040S U ............134 E2040S F .............135

11 SOLID C4314A U ............118

STRANDED

12 SOLID

STRANDED C6506A B ..............37 C2467A U ..............11 C4067A U ..............12 C4109A U ..............18 E1012S U ............134 E2012S F .............135

C6360A U ..............13 C1212 B,C .............41 C2412A U ..............13 C3179 U-P .............16 C3182 F-P .............27 C4131A U ..............19 E1041S U ............134 E2041S F .............135

C2427A U ..............14 C4142A U ..............20

15 SOLID C4301A U ............118 C4315A U ............118

STRANDED C0538A FB ............72 C0947A FB ............70 C6507A B ..............37

C0688A FB ............72 C0746A F ..............68 C0959A FB ............70 C2473A U ..............11 C4225A F ..............31

C0766A F ..............69 C0979A FB ............71 C4073A U ..............12 C4110A U ..............18

C6358A U ..............13 C0786A F ..............69 C4124A U ..............19

C2423A U ..............13 C4132A U ..............19

C2428A U ..............14 C4143A U ..............20

18 SOLID

STRANDED C4111A U ..............18

19 SOLID

STRANDED C2424A U ..............13 C4133A U ..............19

C2429A U ..............14 C4144A U ..............20

20 SOLID C4302A U ............118 C4316A U ............118

STRANDED C6508A B ..............37 C0747A F ..............68 C0960A FB ............70 C4226A F ..............31

C0767A F ..............69 C0980A FB ............71 C4075A U ..............12 C4112A U ..............18

C0787A F ..............69

21 SOLID C4317A U ............118

STRANDED

25 SOLID

STRANDED C0948A FB ............41 C0748A F ..............68 C0961A FB ............70 C4227A F ..............31

C0768A F ..............69 C0981A FB ............71 C4076A U ..............12 C4113A U ..............18

C0788A F ..............69 C2433A U ..............13 C4134A U ..............19

C2436A U ..............14 C4145A U ..............20

30 SOLID C4318A U ............118C4343A F ............120

STRANDED C0749A F ..............68 C4228A F ..............31

C4077A U ..............12 C4114A U ..............18

40 SOLID

STRANDED C0750A F ..............68 C4229A F ..............31

C4079A U ..............12 C4116A U ..............18

50 SOLID

STRANDED C0751A F ..............68 C4230A F ..............31

C4079A U ..............12 C4116A U ..............18

Multi-Conductor Cable Product Finder

Page 234: Cross-Reference & Online Spec Sheets - Datasheet Archive

223

Technical Information Electronics

B - BRAID SHIELD IFB - INDIVIDUAL FLEXFOIL® + FLEXFOIL® /BRAID UJ - UN-JACKETEDC - CAROLPRENE® P - PLENUM

F - FLEXFOIL® SHIELD R - RUBBER FB - FLEXFOIL® /BRAID SHIELD S - SPIRAL SHIELD I - INDIVIDUAL FLEXFOIL® SHIELD U - NO SHIELD

NO. PAIRS

STRAND TYPE

AWG 28 AWG 24 AWG 23 AWG 22 AWG 20 AWG 18P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE

1 SOLID C4008A U ...........................9, 43

STRANDED 740601 IF .............................166740501 IF .............................167740701 IF .............................168C0600A F ...............................73 C0841A FB .............................76 C4841A FB .............................76 C4170A F ...............................53 C4209A F ...............................53C8117 FB-P ............................57C8127 F-P ..............................51

C3204 F-P .............................48 C0720A F ...............................73 C4183A F ...............................54C7104A F ...............................46C7112A FB .............................66C8103 F-P ..............................49C8109 F-P ..............................49C8124 F-P ..............................51C8126 F-P ..............................51

C6101A U ...............................44C8101 F-P ..............................49 C8104 F-P ..............................49C8123 F-P ..............................51

2 SOLID C4413 U ...............................138 C1670A F ...............................46 C4010A U ...............................43

STRANDED C0804A FB .............................79 C0515A FB .............................78 C0601A F ...............................73 C0620A FB .............................75 C0829A FB .............................77 C0842A FB .............................76 C0890A F ...............................74 C0910A IF...............................83 C0924A IFB ............................84 C3028 F-P ..............................56 C3150 F-P ..............................48 C3214 F-P ..............................55 C4171A F ...............................53 C4842A F ...............................76C8118 F-P ..............................50C8128 IF-P .............................64C8129 FB-P ............................57C8134 IF-P .............................62

C0550A F ...............................66 C0570A IF...............................65 C0650A FB .............................75 C0721A F ...............................73 C1338A B .............................161 C1350A IF...............................60 C1352A IF...............................58 C1353A IF...............................58 C3156 IF-P .............................61 C3205 F-P ..............................48 C3352 F-P ..............................52 C4184A F ...............................54 C4203A IF...............................59 C6010A U ...............................43C7114A FB .............................66C8105 IF-P .............................62C8112 IF-P .............................63

C7106A IF...............................58 C0560A F ...............................66 C0584A IF...............................65 C3362 F-P ..............................52 C6118A U ...............................44

3 SOLID C4328A U .............................129 C6035A F ...............................81

STRANDED C0805A FB .............................79 C0516A FB .............................78 C0602A F ...............................73 C0621A FB .............................75 C0830A FB .............................77 C0843A FB .............................76 C0901A F ...............................74 C0911A IF...............................83 C0925A IFB ............................84 C3029 F-P ..............................56 C3153 F-P ..............................48 C3215 F-P ..............................55 C4172A F ...............................53 C4843A FB .............................76 C6065A IF...............................82C8113 F-P ..............................51

C0551A F ...............................66 C0571A IF...............................65 C0651A FB .............................75 C0722A F ...............................73 C3157 IF-P .............................61 C3206 F-P ..............................48 C3353 F-P ..............................52 C4185A F ...............................54 C6014A U ...............................43 C6040A IF...............................82C7116A FB .............................66C8131 IF-P .............................62C8132 IF-P .............................63

C6052A IF...............................82 C6061A IF.............................165

C0561A F ...............................66 C0585A IF...............................65 C6047A IF...............................82 C6103A U ...............................44

4 SOLID E1842S U .............................162 E3842S UP ...........................162

E1843S U .............................162 E3843S UP ...........................162

C1676A F ...............................46 C4015A U ...............................43

STRANDED C0806A FB .............................79 740604 IF .............................166740504 IF .............................167740704 IF .............................168C0517A FB .............................78 C0603A F ...............................73 C0831A FB .............................77 C0844A FB .............................76 C0893A F ...............................74 C0912A IF...............................83 C0926A IFB ............................84 C3030 F-P ..............................56 C3151 F-P ..............................48 C3216 F-P ..............................55 C4173A F ...............................53 C4844A FB .............................76

C0552A F ...............................66 C0572A IF...............................65 C0652A FB .............................75 C0723A F ...............................73 C3207 F-P ..............................48 C3354 F-P ..............................52 C4186A F ...............................54

C1368A IF...............................80 C0562A F ...............................66 C0586A IF...............................65 C3364 F-P ..............................52 C6119 U .................................44

4.5 SOLID

STRANDED C3217 F-P ..............................55

5 SOLID C6120A U ...............................31

STRANDED C0807A FB .............................79 C0518A FB .............................78 C0604A F ...............................73 C0623A FB .............................75 C0832A FB .............................77 C4174A F ...............................53

C0653A FB .............................75 C0724A F ...............................73 C4187A F ...............................54

Multi-Paired Cable Product Finder

Page 235: Cross-Reference & Online Spec Sheets - Datasheet Archive

224

Electronics Technical Information

B - BRAID SHIELD IFB - INDIVIDUAL FLEXFOIL® + FLEXFOIL® /BRAID UJ - UN-JACKETEDC - CAROLPRENE® P - PLENUM

F - FLEXFOIL® SHIELD R - RUBBER FB - FLEXFOIL® /BRAID SHIELD S - SPIRAL SHIELD I - INDIVIDUAL FLEXFOIL® SHIELD U - NO SHIELD

NO. PAIRS

STRAND TYPE

AWG 28 AWG 24 AWG 23 AWG 22 AWG 20 AWG 18P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE

6 SOLID C1671A F ...............................46 C4329A U .............................129C6036A IF...............................81

C4333A U .............................129

STRANDED 740706 IF .............................168 C0519A FB .............................78 C0605A F ...............................73 C0624A FB .............................75 C0839A FB .............................77 C0899A F ...............................74 C0913A IF...............................83 C3031 F-P ..............................56 C3165 F-P ..............................48 C3218 F-P ..............................55 C4175A F ...............................53 C6066A IF...............................82

C0553A F ...............................66 C0573A IF...............................65 C0654A FB .............................75 C0725A F ...............................73 C3208 F-P ..............................48 C3356 F-P ..............................52 C4188A F ...............................54 C6017A U ...............................43 C6041A IF...............................82

C6053A IF...............................82 C6062A IF.............................165

C0563A F ...............................66 C0587A IF...............................65 C6048A IF...............................82 C6106A U ...............................44

7 SOLID

STRANDED C0808A FB .............................79 C0520A FB .............................78 C0606A F ...............................73 C0625A FB .............................75 C0833A FB .............................77 C4176A F ...............................53

C0655A FB .............................75

8 SOLID

STRANDED 740608 IF .............................166740508 F ..............................167740708 IF .............................168 C0521A FB .............................78 C0607A F ...............................73 C0626A FB .............................75 C4177A F ...............................53

C0656A FB .............................75 C6121A U ...............................44

9 SOLID C1672A F ...............................46

STRANDED 740709 IF .............................168 C0608A F ...............................73 C0914A IF...............................83 C4178A F ...............................53 C6067A IF...............................82

C0554A F ...............................66 C0574A IF...............................65 C0726A F ...............................73 C4189A F ...............................54 C6042A IF...............................82

C6054A IF...............................82 C0564A F ...............................66 C0588A IF...............................65 C6049A IF...............................82 C6109A U ...............................44

10 SOLID

STRANDED C0810A FB .............................79 C0522A FB .............................78 C0609A F ...............................73 C0628A FB .............................75 C0835A FB .............................77 C4179A F ...............................53

C0658A FB .............................75

11 SOLID

STRANDED C0915A IF...............................83 C6043A IF...............................82

12 SOLID C4330A U .............................129

STRANDED C0812A FB .............................79 740512 IF .............................167740612 IF .............................166740712 IF .............................168 C0836A FB .............................77 C0916A IF...............................83

C6059A IF...............................82 C6056A IF...............................82 C6050A IF...............................82

12.5 SOLID

STRANDED C0523A FB .............................78 C0630A FB .............................75 C0897A F ...............................74 C3152 F-P ..............................48

C0660A FB .............................75

15 SOLID C1673A F ...............................46C4331A U .............................129

STRANDED C0524A FB .............................78 C0610A F ...............................73 C0917A IF...............................83 C4180A F ...............................53

C0728A F ...............................73 C4190A F ...............................54 C6044A IF...............................82

C6058A IF...............................82 C6051A IF...............................82

Multi-Paired Cable Product Finder

Page 236: Cross-Reference & Online Spec Sheets - Datasheet Archive

225

Technical Information Electronics

B - BRAID SHIELD IFB - INDIVIDUAL FLEXFOIL® + FLEXFOIL® /BRAID UJ - UN-JACKETEDC - CAROLPRENE® P - PLENUM

F - FLEXFOIL® SHIELD R - RUBBER FB - FLEXFOIL® /BRAID SHIELD S - SPIRAL SHIELD I - INDIVIDUAL FLEXFOIL® SHIELD U - NO SHIELD

NO. PAIRS

STRAND TYPE

AWG 28 AWG 24 AWG 23 AWG 22 AWG 20 AWG 18P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE P/N SHIELD PAGE

16 SOLID

STRANDED 740516 IF .............................167740616 IF .............................166740716 IF .............................168

17 SOLID

STRANDED C6060A IF...............................82

18 SOLID

STRANDED C0525A FB .............................78

19 SOLID

STRANDED C0611A F ...............................73 C4181A F ...............................53

C6045A IF...............................82

20 SOLID

STRANDED 740520 IF .............................167740620 IF .............................166740720 IF .............................168

25 SOLID

STRANDED C0526A FB .............................78 C0612A F ...............................73 C4182A F ...............................53

27 SOLID C4332A U .............................129

STRANDED C6046A IF...............................82

28 SOLID

STRANDED 740528 IF .............................167740728 IF .............................168

42 SOLID

STRANDED 740542 IF .............................167740742 IF .............................168

51 SOLID C6451A F ...............................47

STRANDED

52 SOLID

STRANDED 740552 IF .............................167740742 IF .............................168

Multi-Paired Cable Product Finder

Page 237: Cross-Reference & Online Spec Sheets - Datasheet Archive

226

Electronics Technical Information

Reprinted with permission from NFPA 70-2008 National Electrical Code ®, copyright © 2008, National Fire Protection Association, Quincy, MA 02269. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety.National Electrical Code® and the NEC© are registered trademarks of the NFPA.

Communication wire and cable for premise installations in accordance with Article 800, and other applicable parts of the National Electrical Code (NEC), latest issue. Communication wire and cables for Canada are in accordance with the harmonized Canadian Standard Association C22.2 No. 214, Underwriters Laboratories UL 444, latest issue.

FREE RESISTANCE LEVEL TEST REQUIREMENTNEC ARTICLE

800 725 760 820

(Highest) Plenum Cables NFPA 262 (Steiner Tunnel) CSA-CMP (Steiner Tunnel) CMP CL3P

CL2P FPLP CATVP

Riser CablesMultiple Floors

UL-16666 (Vertical Shaft)CSA-CMG (Vertical Tray)

CL3RCL2R FPLR CATVR

General-Purpose Cables UL-1581 (Vertical Tray) CMG CL3 FPL CATV

(Lowest) ResidentialCables Restricted Use

CSA-CMG (Vertical Tray)UL-1581 VW-1 CMX CL2

CL3X CATVX

Notes: 1. Cables with a higher fire resistance level may be substituted for those with a lower fire resistance level. 2. Non-fire rated outside plant telephone cables may not run outside of a rigid metal conduit more than 50 feet from

the point of entrance into a building. 3. Cables rated cmg or cm may be used in runs penetrating one floor. (nec 800-53)

ARTICLE 800Table 800-53. Cable Uses and Permitted Substitutions

CABLE TYPE USE REFERENCE PERMITTED SUBSTITUTIONS

CMP (FT-6) Communications plenum cable 800-53 (a)

CMR (FT-4) Communications riser cable 800-53 (b) CMP

CMG (FT-4)CM (FT-1)

Communications general purpose cable 800-53 (c) CMP, CMR, MPG, MP

CMX (FT-1) Communications cable,limited use 800-53 (d) CMP, CMR, CMG, CM

Note: See Figure 800-53, Cable Substitution Hierarchy

ARTICLE 725Table 725-61. Cable Uses and Permitted Substitutions

CABLE TYPE USE REFERENCE PERMITTED SUBSTITUTIONS

CL3P Class 3 plenum cable 725-61(a) CMP

CL2P Class 2 plenum cable 725-61(b) CMP, CL3P

CL3R Class 3 riser cable 725-61(b) CMP, CL3P, CMR

CL2R Class 2 riser cable 725-6 (b) CMP, CL3P, CL2P, CMR, CL3R

PLTC Power-limited tray cable 725-61(c)and (d)

CL3 Class 3 cable 725-61(b),(e) and (f)

CMP, CL3P, CMR, CL3R, CMG, CM, PLTC

CL2 Class 2 cable 725-61(b),(c) and (f)

CMP, CL3P, CL2P, CMR, CL3R, CL2R, CMG, CM, PLTC, CL3

CL3X Class 3 cable, limited use 725-61(b) and (e)

CMP, CL3P, CMR, CL3R, CMG, CM, PLTC, CL3, CMX

CL2X Class 2 cable, limited use 725-61(b) and (e)

CMP, CL3P, CL2P, CMR, CL3R, CL2R, CMG, CM, PLTC, CL3, CL2, CMX, CL3X

Note: See Figure 725-61, Cable Substitution Hierarchy

Type CM — Communications wires and cablesType CL2 and CL3 — Class 2 and Class 3 remote-control, signaling and power-limited cablesType PLTC — Power-limited tray cable

A → B Cable A shall be permitted to be used in place of Cable B

Figure 725-61, Cable Substitution Hierarchy

CMP

CMR

CMG CM

CMX

CL3P

CL3R

PLTC

CL3

CL3X

CL2P

CL2R

CL2

CL2X

Plenum

Riser

General Purpose

Dwellings

Type CM — Communications cables

A → B Cable A shall be permitted to be used in place of Cable B

Figure 800-53, Cable Substitution Hierarchy

*CMG can be substituted CM—CM can be substituted for CMG

CMP

CMR

CMG CM

CMX

Plenum

Riser

General Purpose

Dwellings

*

NEC/CEC Substitution Chart

Page 238: Cross-Reference & Online Spec Sheets - Datasheet Archive

227

Technical Information Electronics

Article 760Table 760-154 (D). Cable Uses and Permitted Substitutions

CABLE TYPE USE REFERENCES

PERMITTED SUBSTITUTIONS

MULTICONDUCTOR

FPLP Power-limited fire alarm plenum cable

760-154 (A) CMP

FPLR Power-limited fire alarm riser cable

760-154 (B) CMP, FPLP, CMR

FPL Power-limited fire alarm cable

760-154 (C) CMP, FPLP, CMR, FPLR, CMG, CM

Note: See Figure 760-154 (D), Cable Substitution Hierarchy

Article 820Table 820-154 (E). Coaxial Cable Uses and Permitted Substitutions

CABLE TYPE USE REFERENCES PERMITTED SUBSTITUTIONS

CATVP Coaxial plenum cable 820-154 (A) CMP, BLP

CATVR Coaxial riser cable 820-154 (B) CATVP, CMP, CMR, BMR, BLP, BLR

CATV Coaxial general purpose cable

820-154 (C) CATVP, CMP, CATVR, CMR, CMG, CM, BMR, BM, BLP, BLR, BL

CATVX Coaxial cable, limited use 820-154 (C) CATVP, CMP, CATVR, CMR, CATV, CMG, CM, BMR, BM, BLP, BLR, BL, BLX

Note: See Figure 820-154 (E), Cable Substitution Hierarchy

Type CM — Communications wires and cablesType FPL — Power-limited fire alarm cables

A → B Cable A shall be permitted to be used in place of Cable B

No. 26 AWG minimum

Figure 760-154 (D), Cable Substitution Hierarchy

CMP

CMR

CMG CM

FPLP

FPLR

FPL

Plenum

Riser

General Purpose

Multiconductor Cables

Type BL — Network-powered broadband communications low-power cablesType BM — Network-powered broadband communications medium-power cablesType CATV — Community antenna television cablesType CM — Communications cables

A → B Coaxial Cable A shall be permitted to be used in place of Coaxial Cable B

Figure 820-154 (E), Cable Substitution Hierarchy

CMP

CMR

CMG CM

CMX

CATVP

CATVR

CATV

CATVX

BLP

BMR, BLP, BLR

BMR, BM, BLP, BLR, BL

BMR, BM, BLP, BLR, BL, BLX

Plenum

Riser

General Purpose

Dwellings

Reprinted with permission from NFPA 70-2002 National Electrical Code ®, copyright © 2008, National Fire Protection Association, Quincy, MA 02269. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety.National Electrical Code® and the NEC© are registered trademarks of the NFPA.

NEC/CEC Substitution Chart

Page 239: Cross-Reference & Online Spec Sheets - Datasheet Archive

228

Electronics Technical Information

UL Listed Mark for the United States

UL Listed Mark for Canada

UL Listed Mark for Canada and the United States

UL Recognized Component Mark for the United States

TIA/EIA 568A Cat. 3

TIA/EIA 568B Cat. 5e & Cat. 6

California State Fire Marshal

RoHS Compliant Directive

2002/95/EC

CSA CMP

CSA CMG

CSA CMH

NFPA 262 and CSA FT-6 Steiner Tunnel Fire Tests

UL Vertical Tray Flame Test

UL 1666 Riser Flame Test

IMSA

Agency Symbols

Page 240: Cross-Reference & Online Spec Sheets - Datasheet Archive

229

Technical Information Electronics

AGENCY PAGE(S)

CSA Type TEW ............................................................................ 3, 5CSA TR-64 ...................................................................................... 2CSA Type LVT .............................................................................. 141MIL-W-16878 TYPE B ................................................................... 37MIL-W-76B ...................................................................................... 4UL Type AWM............................................................................... 5-6UL Type CL2 ................................................................................ 142UL Type MTW ............................................................................... 5-6UL Type TFF .................................................................................... 5UL Type THW .................................................................................. 6UL Type 1007 .......................................................................... 2, 156UL Type 1015 .................................................................................. 3UL Type 1569 .................................................................................. 2UL Type 2092 .......................................................................... 23, 35UL Type 2093 ................................................................. 23, 35, 159UL Type 2094 ....................................................23, 35, 38, 160-161UL Type 2095 ....................................................33, 36, 47, 159-160UL Type 2106 ................................................................................ 23UL Type 2107 ................................................................................ 23UL Type 2448 ................................................................................ 74

UL Type 2464 .........................................9-14, 18-20, 23, 25, 30-31, 43-44, 53-54, 58, 60, 65-66, 68-71, 73, 75, 81UL Type 2493 ........................................................................... 83-84UL Type 2576 .....................................................................11-13, 60UL Type 2587 ................................................................................ 14UL Type 2717 ................................................................................ 58UL Type 2835 ........................................................................ 58, 160UL Type 2919 ...............................................................72, 76-78, 82UL Type 2960 ................................................................................ 79

Agency Approval Index

Jacket Color Code Chart Put-Ups

CODE COLOR CODE PACKAGING1 BLACK R5/15 250' Spool2 WHITE R8/18 500' Spool3 RED 21 1000' Spool4 ORANGE 30 1000' Spooless Pull-Pac® Carton5 YELLOW 35 250' Reel6 GREEN 38 500' Reel7 DARK BLUE 41 1000' Reel8 BROWN 44 2500' Reel10 GREY 46 5000' Reel13 PINK 85 250' Coil16 LIGHT BLUE 99 Factory Reel19 PURPLE A3 Spool-Pac® 1000'77 WHT/BLK/BLU

Page 241: Cross-Reference & Online Spec Sheets - Datasheet Archive

230

Electronics Technical Information

PUT-UP CODESPUT-UP CODE PACKAGING

PUT-UP CODE PACKAGING

03061112131518202124252627303132333435363839404142434445464748495051525354555657

3 ft Coax w/Connector HD6 ft Coax w/Connector HD50 ft Spool100 ft SpoolClamshell250 ft Spool500 ft Spool900 ft Spool1000 ft Spool2500 ft Spool500 ft Pull-Pac5000 ft Spool500 ft Pull-Pac1000 ft Pull-Pac1000 ft Pull-Pac150 ft Reel100 ft Reel200 ft Coil250 ft Reel300 ft Reel500 ft Reel500 Meter (1640')Long Length Reel1000 ft Reel1500 ft Reel2000 ft Reel2500 ft Reel4000 ft Reel5000 ft Reel7500 ft Reel10,000 ft Reel1600 ft Reel1000 Meter (3280')4500 ft Reel3000 ft Reel25 ft Cuff12 ft Clamshell25 ft Clamshell50 ft Clamshell100 ft Clamshell

5859606162636465666768697073747576777879808586888990919293949699XX

A1A2A3A4R5R8

12 ft Sleeve w/connectors25 ft Sleeve w/connectorsCord Hanked, coil w/cuffCord Set BoxCord Set BagCord Set Sleeve50 ft Sleeve w/connectors100 ft Sleeve w/connectors50 ft Cuff100 ft Cuff3500 ft ReelRetail Spool-PacCord Hanked, coil w/cuffCord Set, long length12' Clamshell w/connectors25' Clamshell w/connectors50' Clamshell w/connectors100' Clamshell w/connectors15,000 ft Reel8,000 ft ReelBlister Pack w/connectors250 ft Coil500' Shrinkwrap coil12' Sleeve w/o connector25' Sleeve w/o connector50' Sleeve w/o connector75' Sleeve w/o connector100' Sleeve w/o connectorBulk ReelDisplayWiring Device, Skin PackFactory ReelVarious Lengths

250 ft Spool-Pac500 ft Spool-Pac1000 ft Spool-Pac2000 ft Spool-Pac250 ft Spool, Retail500 ft Spool, Retail

CONDUCTOR COLOR CONDUCTOR COLOR

1st2nd3rd4th5th6th7th8th9th

10th11th12th13th14th15th

BlackRedGreenBlueBrownOrangeBlack w/White StripeRed w/White StripeGreen w/White StripeYellow w/White StripeRed w/Black StripeGreen w/Black StripeYellow w/Black StripeGreen w/Red StripeYellow w/Red Stripe

16th17th18th19th20th21st22nd23rd24th25th26th27th28th29th30th

White w/Brown StripeGreen w/Brown StripeYellow w/Brown StripeWhite w/Orange StripeBlack w/Orange StripeRed w/Orange StripeGreen w/Orange StripeBrown w/Orange StripeWhite w/Blue StripeRed w/Blue StripeYellow w/Blue StripeBrown w/Blue StripeBlack w/Red StripeWhite w/Red StripeBrown w/Red Stripe

PAIR COLOR PAIR COLOR

1st2nd3rd4th5th6th7th8th9th

10th11th12th13th14th15th

Black & RedBlack & WhiteBlack & GreyBlack & BlueBlack & YellowBlack & BrownBlack & OrangeBlack & PurpleRed & WhiteRed & BlueRed & YellowRed & BrownRed & OrangeWhite & BlueWhite & Yellow

16th17th18th19th20th21st22nd23rd24th25th26th27th

White & BrownWhite & OrangeBlue & YellowBlue & BrownBlue & OrangeBrown & YellowBrown & OrangePurple & RedPurple & WhitePurple & BluePurple & BrownPurple & Yellow

JACKET COLOR CODESCOLOR CODE JACKET COLOR

COLOR CODE JACKET COLOR

00010203040506070809101112131415161718192021222324253133343536373839404142434445

UninsulatedBlackWhiteRedOrangeYellowGreen Dark BlueBrownMaroonGrayAntique GoldIvoryPinkLight GreenClear GoldLight BlueBeigeLight BrownPurpleClear SilverLight PurpleNeon GreenMint GreenRaspberryGoldWhite/BlackWhite/RedWhite/OrangeWhite/YellowWhite/GreenWhite/BlueWhite/BrownWhite/VioletWhite/GrayRed/GreenGreen/WhiteBlue/RedBlue/WhiteOrange/Red

46474849505662666768697071727374757677787980818286889091929396979899

Orange/BlackYellow/WhiteYellow/BlackBlue/WhiteBlue/BlackBlack w/White TraceSilver Gray (Lt Gray)Light GreenLime GreenBirchMapleWalnutWrought IronCopperWhite/Black/RedWhite/Black/OrangeWhite/Black/YellowWhite/Black/GreenWhite/Black/BlueWhite/Black/BrownWhite/Black/VioletWhite/Black/GrayBlack/Red/WhiteOrange/Green/BlackNaturalTanClearClear BrownClear BlueClear RedTwisted Cond. No Jkt1 Stripe2 StripesAssorted Colors

CSA FIRE ALARM COLOR CODE CHART

Put-Ups and Color Codes

Page 242: Cross-Reference & Online Spec Sheets - Datasheet Archive

231

Technical Information Electronics

Applications Index

AAccess control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114, 131-133Addressable Fire Alarm Systems . . . . . . . . . . . . . . . . . . . 125-128Alliance Ham/CB and TV rotors compatibility . . . . . . . . . . . . . .139Amplifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152, 169Analog video. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102, 115, 167Analog/digital video . . . . . . . . . . . . . . . . . . . . . . . . . . . 99, 102, 115Analog/digital video broadcast-grade monitors . . . . . . . . . . . . . 93Annunciator systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141-143Audio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25, 39, 134-137, 159Audio components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166-168Audio interconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40-41Audio systems . . . . . . . . . . . . . . . . . . . . . . 15-17, 25, 27-28, 45-46, 148, 156, 172, 175Audio/image/video products . . . . . . . . . . . . . . . . . . . . . . . . . . . .183Automatic valve control systems . . . . . . . . . . . . . . . . . . . . . . . . . .22

BBackground music . . . . . . . . . . . . . . . . . . . .16-17, 27-28, 134-137Basses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169Bell systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141-143Bi-amp speakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152-153Broadcast . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94, 100, 107-108, 112Broadcast and sound systems . . . . . . . . . . . . . . . . . . 23, 25, 29-30Broadcast and studio. . . . . . . . . . . . . . . . . . . . . . . . . . 35, 38, 40-41Broadcast and studio requirements. . . . . . . . . . . . . . . . . . . . . . . .21Broadcast and studio use . . . . . . . . . . . . . . . . . . . . . . . . . .172, 175Broadcast digital video . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96-98Broadcast grade. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105-106Broadcast-grade headend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92Broadcast/HDTV . . . . . . . . . . . . . . . . . . . . . .88-93, 96-99, 107-108Broadcast/Serial Digital Interface (SDI) . . . . . . . . . . . . . 92, 106-107Broadcast-grade Serial Digital Interface (SDI) . . . . . . . . . . . . . . . .99Burglar alarms . . . . . . . . . . . . . . . . . . . . . . .22, 32, 65-66, 116-121, 123, 129, 141-143Business machines . . . . . . . . . . . . . . . . . . . . . . . . . . . 22, 32, 65-66

CCable tray installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22, 32CAD/CAM systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78 Card readers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .114Cash registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22, 32, 65Cat 5e ScTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163Cat 5e UTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163CATV . . . . . . . . . . . . . . . . . . .86-92, 96-99, 101-106, 110-115, 150CATV/headend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92CCTV . . . . . . . . . . . . . . . . . . . . . . . . 86-88, 90-92, 96-99, 101-102, 104-105, 110, 114-115, 162, 177Commercial broadcast facilities . . . . . . . . . . . . . . . . . . . . . . . . .158Communication and audio system . . . . . . . . . . . . . . .148, 172, 175Communication and control . . . . . . . . . . . . . . . . . . . . . . . . . . .161

Communication circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46Communications . . . . . . . . . . . . . . . . . . 66, 114, 116-129, 159-160Computer and computer interconnections . . . . . . . . 23-24, 26, 29, 31, 60, 68-69, 78Computer interconnections . . . . . . . . . . . . . . . 24, 31, 60, 68-69, 78Computer/networks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109Computers . . . . . . . . . . . . . . . . 29, 39, 43-44, 49-51, 53-54, 57-59, 62-64, 70-77, 79-84, 95, 112, 183-184Console board equipment . . . . . . . . . . . . . . . . . . . . . . . . . 166-168Control circuits . . . . 9, 11-21, 24, 26-28, 31, 39-41, 43-45, 48-64, 68-84, 134-138, 152-153, 172, 175, 185Cue line systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177

DData and signal transmission . . . . . . . . . . . . . . . . . . . . . . . . . . . .24Data transmission . . . . . . . . . . . . . . . . 31, 43-44, 53-54, 60, 68-71, 73-77, 79, 95, 100, 112, 163DBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86, 90-92, 115Digital audio . . . . . . . . . . . . . . . . . . . . . . . . 147-148, 151, 157, 166Digital audio interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153Digital data transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183Digital video cameras/displays/recorders . . . . . . . . . . . . . . . . . .183Digital/audio . . . . . . . . . . . . . . . . . . . . . . . . 147-148, 151-157, 166Direct broadcast satellite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90Direct burial . . . . . . . . . . . . . 26, 89, 97-98, 104, 139-140, 164-165Disc arrays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183-184Door bells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141-143Door control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132-133Drop cable . . . . . . . . . . . . . . . . . . . . . . . . . . . 88, 91-92, 96-99, 103

EEIA RS-232 circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . 48, 52, 55-58EIA RS-232 systems . . . . . . . . . . . . . . 11-14, 18-20, 30-31, 43-44, 54-56, 68-73, 75, 77-79EIA RS-422 circuits . . . . . . . . . . . . . . . . . . . . . . . . 55-56, 77, 79, 83EIA RS-423 systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72, 78Effects pedals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169Electronic instrumentation control systems . . . . . . . . . . . . . . . . .47EMI isolated circuits for instrumentation . . . . . . . . . . . . . . 159-160Energy management systems . . . . . . . . . . . . . . . . . . . . . . . . . . . .21Excellent shielding for noise reduction . . . . . . . . . . . . . . . . . . 34-38External wiring of machinery . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6

FFire alarm control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21Fire alarm systems . . . . . . . . . . . . . . . . . . . . . . . . . . . 122, 124-129Fire protective circuits . . . . . . . . . . . . . . . . . . . . . . . . . 117-121, 123FM broadcast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88, 91

GGeneral-purpose audio applications . . . . . . . . . . . . . . . . . . . . . .170Good flexibility . . . . . . . 23, 29-31, 34, 36-37, 53-54, 70-72, 75-79Guitars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169

Page 243: Cross-Reference & Online Spec Sheets - Datasheet Archive

232

Electronics Technical Information

Applications Index

HHDTV . . . . . . . . . . . . . . . . . . . . . . . . . . 86-93, 96-99, 107-108, 115Heating and air conditioning installations . . . . . . . . . . . . . . 141-143Helical binding or overall jacketing . . . . . . . . . . . . . . . . . . . . . . .163Hi-fi and stereo speaker wire . . . . . . . . . . . . . . . . . . . . . . . 156-157High speed computer interconnects . . . . . . . . . . . . . . . . . . . . . . .78High speed computers . . . . . . . . . . . . . . . . . . . . . . . . . . . 72, 83-84High speed solid state circuits for low-voltage applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182High-end microphones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148High-impedance microphones . . . . . . . . . . . . . . . . . . . . . .172, 175Home entertainment . . . . . . . . . . . . . . . . . . 147-148, 151-156, 170Home theater . . . . . . . . . . . . . . . 114, 116, 147-148, 151-153, 156

IIndustrial control systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32Industrial equipment . . . . . . . . . . . . . . . 43-44, 53-54, 58-59, 70-84Industrial equipment control . . . . . . . . . . . . . . 23, 29-31, 60, 68-69IEEE 802.3 and ISO/IEC 8802.3 10 Base 5 LAN computer cables . . . . . . . . . . . . . . . . . . . . . . . .95IEEE 802.3 and ISO/IEC 8802.3 10 Base 2 computer cables . . . . . . . . . . . . . . . . . . . . . . . . . . . .95Instrumentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150, 159-161Instrumentation and control use . . . . . . . . . . . . . . . . . . . . . . . . . .46Instrumentation systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25, 47Intercom systems . . . . . . . . . . . . . . . . . . .16-17, 22, 27-28, 32, 47, 65-66, 138, 141-143Intercoms . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9, 11-14, 18-20, 116Interconnection components . . . . . . . . . . . . . . . . . . . . . . . 166-168Internal telephones . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-14, 18-20Internal wiring, electrical/electronic equipment, panels/meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5In-wall speakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147, 151-155Irrigation systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

JJukeboxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156-157

KKeyboards and other instruments to amplifiers, mixers, and effects pedals . . . . . . . . . . . . . . . . . . . . . . . . . . . .169

LLAN and data transmission . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100LAN and data transmission computer cables . . . . . . . . . . . . . . .95LAN cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90Line level microphone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167-168Line level signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167-168Local area network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101-104Low capacitance applications . . . . 35, 38, 72, 74, 83-84, 166-169Low capacitance requirements . . . . . . . . . . . . . . . . . . 56, 76-77, 79Low cost alternative to laminated bus bars . . . . . . . . . . . . . . . .182Low inductance DC applications . . . . . . . . . . . . . . . . . . . . . . . .182

Low signal distortion data requirements . . . . . . . . . . . . . . . . . . . .78Low-voltage installations . . . . . . . . . . . . . . . . . . . . . . . . . . 141-143Low-voltage power distribution, electronic and data processing equipment . . . . . . . . . . . . . . . . . . . . . . .182Low-impedance microphones . . . . . . . . . . . . . . . . . . 172, 174-175Low-voltage golf course satellite sprinkler control . . . . . . . . . . .140

MMATV . . . . . . . . . . . . . . . . . . . 86, 88-89, 96-99, 101-106, 110, 115Mixers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169Monitor applications . . . . . . . . . . . . . . . . . . . . . . . . . . . 93, 107-108Monitor systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177Monitor/VDT display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101-104Motor and transformer lead . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6Multiple cable pulls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163Musical instruments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170

NNoise reduction shielding . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-38Non QPL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4, 37Not for in-wall use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156-158

OOptical fiber cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163Oscillators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7Outdoor installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139Outdoor rated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138-140, 176Outdoor signal processing gear . . . . . . . . . . . . . . . . . . . . . . . . .169Outdoor use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164-165

PParallel or serial transmission . . . . . . . . . . . . . . . . . . . . . . . . . . .184Personal computers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183-184Petrochemical control systems . . . . . . . . . . . . . . . . . . . . . . . . . . .66Petrochemical refineries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32Plenum versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163Point-of-sale systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61Point-to-point wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5Power-limited circuits . . . . . . . . . . . . . . . . . . . . . . . . . 22, 32, 65-66Power-limited control circuits . . . . . . . . . . . . . . . .16-17, 27-28, 48, 52, 55, 61, 134-137Precision video – analog/digital . . . . . . . . . . . . . . . . . . . . . 105-106Primary power distribution, electronic and data processing equipment . . . . . . . . . . . . . . . . . . . . . . .182Process control and instrumentation . . . . . . . . . . . . 15, 26, 39, 45, 48-52, 55-57, 61-64Programmable Logic Controllers (PLC) . . . . . . . . . . . . . . . . . . .112Public address systems . . . . . . . . . . . . . . . . . . . . . . . . 9-14, 18-20Pull boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122, 124-128

RRadio station components, interconnection and audio . . . 166-168Radio transmitters . . . . . . . . . . . . . . . . . . . . . . . 33-34, 36, 171, 173Radios . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33-34, 36, 171, 173

Page 244: Cross-Reference & Online Spec Sheets - Datasheet Archive

233

Technical Information Electronics

Applications Index

Recording studios . . . . . . . . . . . 33-34, 36, 158, 166-168, 171, 173Recording studios and sound stages . . . . . . . . . . . . . . . . 23, 29-30Recording studio components, interconnection and audio . . . . . . . . . . . . . . . . . . . . . . . . 166-168Remote control circuits . . . . . . . . . . . . .9, 11-15, 18-20, 26, 39, 45, 48-52, 55-57, 61-64, 138, 152-153Remote control for studio equipment . . . . . . . . . . . . . . . . . . . . . .37Remote control systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177Remote control units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141-143Residential sprinkler solenoid control . . . . . . . . . . . . . . . . . . . . .140REX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132-133RF shielding . . . . . . . . . . . . . . . . . . . . . . . 24, 33-38, 164, 171, 173RF signal transmission . . . . . . . . . . . . . . . . . . . . 88, 91, 94, 96-111RG6 video/data quad shield coax . . . . . . . . . . . . . . . . . . . . . . .163RGB video . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115, 162Riser versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163Rotor antenna controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139RS-232 circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48, 52, 55-56RS-232 systems . . . . . . . . . . . . . . . . . 11-14, 18-20, 30-31, 43-44, . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53-54, 68-73, 75, 77-79RS-422 circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55-56RS-423 systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72, 78

SSatellite actuator control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101 Satellite receivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115Secondary power distribution, electronic and data processing equipment . . . . . . . . . . . . . . . . . . . . . . .182Security systems . . . . . . . . . . . . . . . . . . . . . . . . . 132-133, 152-153Serial Digital Interface (SDI) . . . . . . . . . . . . . . . . . . .87, 92, 99, 107Shielded cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24, 164Shielded power supplies . . . . . . . . . . . . . . . . . . . . . . .148, 172, 175Shielding, Fire Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183-184Shielding, noise reduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-38Shielding, SCSi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184Shielding, USB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184Signal isolation, total . . . . . . . . . . . . . . . . . . . . . . . . . . 61-64, 80-84Signal systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141-143Smoke detectors . . . . . . . . . . . . . . . . . . . . . . . . . 115, 117, 121-128Sound system installations . . . . . . . . . . . . . . . . . . . . . . . . . 166-168Sound systems . . . . . . . . . . . . . . . . . . . . . . . .23, 25, 29-30, 33-38, 47, 116, 171, 173

Speaker extension service . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138Special audio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159-161Stereo systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148, 151-155Studio use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148, 172, 175Suggested voltage rating: 1000 volts . . . . . . . . . . . . . . . . . . . .174Suggested voltage rating: 1000 volts (MIL-W 76B) . . . . . . . . . . . .4Suggested voltage rating: 150 volts . . . . . . 16-17, 27-28, 52, 138Suggested voltage rating: 200 volts . . . . . . . . . . . . . . . . . . . . .139Suggested voltage rating: 30 volts . . . . . . . . . . . 72, 74, 76-79, 82Suggested voltage rating: 300 or 600 volts . . . . . . . . . . 18-20, 23, 29-31, 53-54, 59Suggested voltage rating: 300 volts . . . 2, 9-15, 22, 24-26, 32-36, 38-41, 43-51, 55-58, 60-66, 68-71, 73, 75, 80-81, 83-84, 117-129, 134-138, 148, 154, 159, 161, 171-173, 175, 185Suggested voltage rating: 350 volts . . . . . . . . . . . . . . 21, 164-165Suggested voltage rating: 600 volts . . . . . . . . . . . . . . . . . . . .3, 37Suitable for EIA RS-232 and RS-423 CAD/CAM applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72Suitable for EIA RS-232 applications . . . . . . . 11-14, 18-20, 30-31, 43-44, 53-54, 68-73, 75, 77-79Suitable for EIA RS-422 applications 77, 79Suitable for EIA RS-422 CAD/CAM applications . . . . . . . . . . . . .83Suitable for EIA RS-485 applications . . . . . . . . . . . . . . . . . . . . . .76

TTelevision station components, interconnection and audio . . . . . . . . . . . . . . . . . . . . . . . 166-168Test equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7Thermostat control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141-143Thicknet/trunk cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95Touch-plate systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141-143Tray cable installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65-66TV broadcast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177TV cameras . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177

VVideo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88-93, 96-98Video and audio interconnecting cables . . . . . . . . . . . . . . .172, 175Video interconnect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38, 38Video – analog/digital . . . . . . . . . . . . . . . . . . . . . . 99, 102, 105-108Voice communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117-129

Page 245: Cross-Reference & Online Spec Sheets - Datasheet Archive

234

Electronics Technical Information

Belden-to-General Cable Carol® Brand Cross Reference Index

BELDEN PART NUMBER

GENERAL CABLE/ CAROL PART NUMBER

PAGENUMBER

1030A C0456A 321031A C0457A 321032A C0454A 321186A C5784 1031189A C5785 89

1189AP C3525 911190A C5804 891242A E1001S 1341266A E2022S 135

1306SB C8029 911307A C1804 1531309A C1802 1531426A C1142 1011502A 495023 1061502P C8125 1851503A C0600A 731505A 395025 1061506A 495023 1061508A C2513A 231513A C5776 881523A C5039 97

1523AP C3528 971525A C5039 971530A C5776 881583A CR5 N/A1585A CP5 N/A1617A C5044 971694A 395011 92

1694SB C5814 901695A 495025 921841A C5822 901855A 395031 1071861A C1004A 1541883A C0600A 731884A C5889 891912A 740512 16719352 86013 N/A3105A C7112A 663107A C7114A 663108A C7116A 665000FE E2062S 1355000UE E1062S 1345002UE E1064S 1345020FL E2542S 1195020UL E1532S 1175100FE E2052S 1355100UE E1052S 1345102A E1054S 134

5102UE E1054S 1345102UP C1803 1535120FJ C0475 1265120FL E2532S 1195120LL E2406S 1175120UL E1522S 117

BELDEN PART NUMBER

GENERAL CABLE/ CAROL PART NUMBER

PAGENUMBER

5122FL E2534S 1195122UL E1524S 117513945 395058 995200FE E2042S 1355200UE E1042S 1345200UP C1804 1535201FE C2537A 235201UE E1043S 1345202FE E2244S 1375202UE E1044S 1345220FL E2522S 1195220LL E2404S 1355220UL E1512S 1175222FL E2524S 1195222UL E1514S 1175300FE E2032S 1355300UE E1032S 1345301FE E2033S 1355301UE E1033S 1345302FE E2034S 1355302UE E1034S 1345304FE E2036S 1355304UE E1036S 1345306FE E2038S 1355306UE E1038S 1345308UE E1040S 1345309UE E1041S 1345300UE E1032S 1345320FE E2030S 1355320FL E2502S 1195320LL E2402S 1175320UE E1030S 1345320UL E1502S 1175321FL E2503S 1195321UL E1503S 1175322FL E2504S 1195322UL E1504S 1175324UL E1506S 1175341A C0560A 66

5342UE C6103A 445400FE E2022S 1355400UE C6351A 135401FE E2023S 1355401UE E1023S 1345402FE E2024S 1355402UE E1024S 134540OUE E1022S 134543945 C1142 101549945 C8028 1045500FE E2002S 1355500UE E1002S 1345501FE E2003S 1355501UE E1003S 1345502FE E2004S 135

This cross reference guide should be used in conjunction with the product information in our catalog or on our website. It should be used for suggested alternative items which are functionally equal. Constructional differences are not indicated. General Cable is not responsible for variances due to competitor and industry constructional changes or agency updates.

Page 246: Cross-Reference & Online Spec Sheets - Datasheet Archive

235

Technical Information Electronics

Belden-to-General Cable Carol® Brand Cross Reference Index

BELDEN PART NUMBER

GENERAL CABLE/ CAROL PART NUMBER

PAGENUMBER

5502UE E1004S 1345504FE E2006S 1355504UE E1006S 1345506FE E2008S 1355506UE E1008S 1345508FE E2010S 1355508UE E1010S 1345509FE E2012S 1355509UE E1012S 134550OUE E1002S 1345520FE E2000S 1355520UE E1000S 1345522UE E1001S 1345522UL E1484S 1175545UE C6106A 445562FE C0722A 73558AFS 4ERS4S 133558GMS 4ERS1S 1336000UC C3129 176000UE E3062S 1366020FL E3632S 1236020UL E3532S 1216100FE E2252S 1376100UE E3052S 1366100UF C3128 176102UE E3054S 1366120FL C3174 1286120UL E3522S 1216122FL E3624S 1236122UL E3524S 1216200FE E2242S 276200UE E3042S 176201FE E2243S 1376201UE E3043S 1366202FE C3341 276202UE E3044S 1366220FL E3612S 1236220UL E3512S 1216222FL E3614S 1236222UL E3514S 1216300FE E2202S 1376300UE E3032S 1366301FE E2203S 1376301UE C3120 176302FE E2204S 1376302UE C3113 176304FE E2206S 1376304UE C3121 176306FE E2208S 1376306UE C3122 176320FE E2200S 1376320FL E3602S 1236320UE E3030S 1366320UL E3502S 121

BELDEN PART NUMBER

GENERAL CABLE/ CAROL PART NUMBER

PAGENUMBER

6321FL E3603S 1236321UL E3503S 1216322FL E3604S 1236322UL E3504S 1216324UL E3506S 121633948 495035 926400FE E2122S 1376400UE E3022S 1366401FE E2123S 1376401UE E3023S 1366402FE E2124S 1376402UE E3024S 136643948 495028 105649948 C8030 1016500FE E2102S 1376500UE E3002S 1366501FE E2103S 1376501UE E3003S 1366502FE E2104S 1376502UE E3004S 1366504FE E2106S 1376504UE E3006S 1366506FE E2108S 1376506UE E3008S 1366520FE E2100S 1376520UE E3000S 1366522UE E3001S 1366541FE C3205 486543A C3151 486545FE C3208 48658AFS 4EPL4S 132658GMS 4EPL1S 1327731A 395029 997732A 495027 997987P E3842S 1627987R E1842S 1627989P E3843S 1627989R E1843S 1628102 C0515A 788103 C0516A 788104 C0517A 788105 C0518A 788106 C0519A 788107 C0520A 788108 C0521A 788110 C0522A 788112 C0523A 788115 C0524A 788118 C0525A 788125 C0526A 788162 C0924A 848163 C0925A 848164 C0926A 848205 C6351A 13

This cross reference guide should be used in conjunction with the product information in our catalog or on our website. It should be used for suggested alternative items which are functionally equal. Constructional differences are not indicated. General Cable is not responsible for variances due to competitor and industry constructional changes or agency updates.

Page 247: Cross-Reference & Online Spec Sheets - Datasheet Archive

236

Electronics Technical Information

Belden-to-General Cable Carol® Brand Cross Reference Index

BELDEN PART NUMBER

GENERAL CABLE/ CAROL PART NUMBER

PAGENUMBER

8212 C1102 1018213 C5025 968214 C1198 948216 C1156 1108218 C1158 1058219 C1188 1008221 C1135 10182241 C3500 10482248 C3523 9182262 C3520 1098228 C5760 888237 C1154 948240 C1166 10082442 E3002S 1368248 C3521 9182489 C8102 1582503 C8113 518259 C1178 1008261 C1160 968262 C1155 1008263 C1106 10182641 C8127 518267 C1176A 11182723 C8105 6282729 C8134 6282740 C8122 4582760 C8123 5182761 C8126 5182777 C8131 6282778 C8133 6282842 C8129 578302 C0650A 758303 C0651A 758304 C0652A 758305 C0653A 758306 C0654A 758307 C0655A 758308 C0656A 758310 C0658A 758312 C0660A 7583206 C8101 498325 C0663A 758332 C0620A 758333 C0621A 758334 C0622A 758335 C0623A 758336 C0624A 758337 C0625A 758340 C0628A 758342 C0630A 7583503 C8115 3983653 C8107 3983654 C8110 3983656 C8120 39

BELDEN PART NUMBER

GENERAL CABLE/ CAROL PART NUMBER

PAGENUMBER

83702 C8111 3983703 C8119 3983706 C8108 398412 C1302 40, 1728418 C1313 408422 C1322A 1748423 C1304 408424 C1305 408425 C1308 408426 C1310 408427 C1312 408428 C1202 41, 1758437 C2676A 348441 C2677A 348442 C6348A 128443 C4062A 128444 C4063A 128445 C4064A 128446 C4081A 108447 C4082A 108448 C4083A 108449 C4084A 108450 C2515A 238451 C2516A 238456 C4071A 128457 C4067A 128458 C4073A 128459 C4076A 128460 C7102A 1568461 C2830A 138465 C2420A 138466 C2412A 138467 C2421A 138468 C2423A 138469 C2422A 138471 C2405A 148473 C2409A 148477 C2410A 148486 C2754A 98488 C1130 1398489 C2404A 138520 C7610A 48521 C7608A 48522 C7606A 48523 C7604A 48524 C7602A 48525 C7600A 48527 C7611A 668612 C3521 918618 C2537A 238619 C2424A 138620 C2425A 148621 C2426A 148622 C2427A 14

This cross reference guide should be used in conjunction with the product information in our catalog or on our website. It should be used for suggested alternative items which are functionally equal. Constructional differences are not indicated. General Cable is not responsible for variances due to competitor and industry constructional changes or agency updates.

Page 248: Cross-Reference & Online Spec Sheets - Datasheet Archive

237

Technical Information Electronics

This cross reference guide should be used in conjunction with the product information in our catalog or on our website. It should be used for suggested alternative items which are functionally equal. Constructional differences are not indicated. General Cable is not responsible for variances due to competitor and industry constructional changes or agency updates.

Belden-to-General Cable Carol® Brand Cross Reference Index

BELDEN PART NUMBER

GENERAL CABLE/ CAROL PART NUMBER

PAGENUMBER

8623 C2428A 148624 C2429A 148627 C2430A 148628 C2431A 148641 C2513A 238649 C1360 1568661 C2426A 148690 C6103A 448691 C6106A 448692 C6109A 448718 C2539A 238719 C2536A 238720 C2538A 238722 C1331A 1608723 C1352A 58

8723SB C1352ACS N/A8724 C1340A 1608725 C1368A 808728 C1353A 588729 C7110A N/A8732 C1338A 1618735 C2678A 368737 C2882A 338740 C4008A 9, 438741 C4010A 438742 C4014A 438743 C4017A 438747 C6017A 438748 C6019A 438749 C6026A 438751 C6451A 478757 C4015A 438759 C2888A 338760 C2534A 238761 C2514A 238762 C2524A 238763 C1333A 1598767 C6035A 818768 C6036A 818769 C6045A 828770 C2535A 238771 C2526A 238772 C2525A 238773 C6046A 828774 C6042A 828775 C6043A 828776 C6044A 8287760 C8104 4987761 C8103 498777 C6040A 82

8777SB C6040ACS N/A8778 C6041A 828780 C2895A 338782 C1356 156

BELDEN PART NUMBER

GENERAL CABLE/ CAROL PART NUMBER

PAGENUMBER

8786 C1345A 1598790 C2892A 338791 C2768A 338795 C4408 13888102 C8118 5088723 C8112 6388760 C8101 4988761 C8109 4988770 C8106 268898 C1318 78899 C1321 78916 C2105A 38917 C2104A 38918 C2103A 38919 C2102A 38920 C2101A 389418 C8114 2688778 C8132 6389729 C8128 6489740 C8116 4589841 C8117 579011 C5034 969066 C5804 899116 C5775 88

9116P C3524 919116R C5886 88

9116SB C5775ACS N/A9117 C5802 899151 C1000A 154

9151SB C2520 249154 E2022S 1359155 C1343A 1609156 C6118A 449157 C6119A 449159 C6120A 449161 C6121A 449182 C8014 1129201 C1117 1009207 C8000 1129209 395031 1079248 C5778 919258 C1108A 949259 C1103 1019265 C8025 1029269 C1164 1099291 C5770 1039302 C1670A 469305 C1676A 469306 C1671A 469309 C1672A 469312 C0460A 329314 C0458A 329315 C1673A 469316 C0456A 32

Page 249: Cross-Reference & Online Spec Sheets - Datasheet Archive

238

Electronics Technical Information

This cross reference guide should be used in conjunction with the product information in our catalog or on our website. It should be used for suggested alternative items which are functionally equal. Constructional differences are not indicated. General Cable is not responsible for variances due to competitor and industry constructional changes or agency updates.

Belden-to-General Cable Carol® Brand Cross Reference Index

BELDEN PART NUMBER

GENERAL CABLE/ CAROL PART NUMBER

PAGENUMBER

9318 C0454A 329320 C0452A 329322 C0450A 329328 C0570A 659329 C0571A 659330 C0572A 659331 C0573A 659332 C0574A 659333 C0575A 659363 C0451A 329364 C0453A 329365 C0455A 329366 C0457A 329367 C0459A 329368 C0584A 659369 C0585A 659388 C0586A 659389 C0587A 659390 C0588A 659391 C0589A 659392 C0590A 659397 C1226A 1739402 C7106A 589406 C1350A 609407 C0431A 229408 C0433A 229409 C0435A 229410 C0437A 229411 C0439A 229412 C0441A 229414 C6010A 439418 C2543A 259421 C4065A 129423 C4070A 129430 C4088A 129431 C4075A 129432 C4077A 129433 C4078A 129434 C4079A 129438 C7108A 79439 C6356A 139444 C6353A 139445 C6355A 139451 C2520A 24

9451P C8124 519451SB C2520A 24

9452 C1228A 1719455 C6357A 139457 C6360A 139458 C6358A 139460 C2521A 249461 C2518A 249462 C7104A 469464 C2519A 24

BELDEN PART NUMBER

GENERAL CABLE/ CAROL PART NUMBER

PAGENUMBER

9491 C0432A 229492 C0434A 229493 C0436A 229494 C0438A 229495 C0440A 229501 C0600A 739502 C0601A 739503 C0602A 739504 C0603A 739505 C0604A 739506 C0605A 739507 C0606A 739508 C0607A 739509 C0608A 739510 C0609A 739512 C0550A 669513 C0551A 669514 C0552A 669515 C0610A 739516 C0553A 669519 C0611A 739520 C0554A 669521 C0555A 669524 C0556A 669525 C0612A 739533 C0741A 689534 C0742A 689535 C0753A 689536 C0743A 689537 C0754A 689538 C0744A 689539 C0755A 689540 C0745A 689541 C0746A 689542 C0747A 689543 C0748A 689544 C0749A 689545 C0750A 689546 C0751A 689552 C0560A 669553 C0561A 669554 C0562A 669556 C0563A 669559 C0564A 669565 C0566A 669608 C0951A 709609 C0952A 709610 C0953A 709611 C0954A 709612 C0955A 709613 C0956A 709614 C0957A 709615 C0958A 709616 C0959A 70

Page 250: Cross-Reference & Online Spec Sheets - Datasheet Archive

239

Technical Information Electronics

This cross reference guide should be used in conjunction with the product information in our catalog or on our website. It should be used for suggested alternative items which are functionally equal. Constructional differences are not indicated. General Cable is not responsible for variances due to competitor and industry constructional changes or agency updates.

Belden-to-General Cable Carol® Brand Cross Reference Index

BELDEN PART NUMBER

GENERAL CABLE/ CAROL PART NUMBER

PAGENUMBER

9617 C0961A 709620 C2434A 149621 C2435A 149622 C2436A 149623 C2437A 149626 C2433A 139637 C0948A 709708 C1357 1569712 C1362 1569716 C1358 1569717 C1361 1569718 C1363 1569721 C2443A 149728 C0912A 839729 C0910A 839730 C0911A 839731 C0913A 839732 C0914A 839733 C0915A 839734 C0916A 839735 C0917A 839740 C6101A 449742 C6111A 449744 C6010A 439745 C6014A 439746 C6015A 439747 C6023A 439768 C6059A 829769 C6060A 829770 C2517A 239773 C6047A 829774 C6048A 829775 C6049A 829776 C6050A 829777 C6051A 829791 C0533A 729794 E1004S 1349802 C2509A 1649803 C2510A 1649804 C0804A 799805 C0805A 799806 C0806A 799807 C0807A 799808 C0808A 799809 C0809A 799812 C0812A 799829 C0829A 779830 C0830A 779831 C0831A 779832 C0832A 779833 C0833A 779835 C0835A 779836 C0836A 779839 C0839A 77

BELDEN PART NUMBER

GENERAL CABLE/ CAROL PART NUMBER

PAGENUMBER

9841 C4841A 769842 C4842A 769843 C4843A 769844 C4844A 769862 C1162 1099863 C8000 1129873 C6052A 829874 C6053A 829875 C6054A 829877 C6056A 829879 C6058A 829883 C6061A 1659886 C6062A 1659890 C2511A 1649899 C1320A 79910 C2107A 39912 C2106A 39913 C1180 949916 C2065A 29918 C2064A 29919 C2040A 29921 C2016A 29923 C2015A 29924 C2100A 39925 C0680A 729927 C0681A 729929 C0682A 729931 C0683A 729932 C0684A 729933 C0685A 729934 C0686A 729935 C0687A 729936 C0688A 729939 C0971A 719940 C0972A 719941 C0973A 719942 C0974A 719943 C0975A 719944 C0976A 719945 C0977A 719946 C0978A 719947 C0979A 719948 C0981A 719990 C6065A 829991 C6066A 829992 C6067A 82

Page 251: Cross-Reference & Online Spec Sheets - Datasheet Archive

240

Electronics Technical Information

CatalogNumber page

CatalogNumber page

CatalogNumber page

CatalogNumber page

Part Number Index

4EPL1S ................................. 1324EPL4S ................................. 1324ERS1S ................................ 1334ERS4S ................................ 13305091 ................................... 14105092 ................................... 14105093 ................................... 14105094 ................................... 14105095 ................................... 14105096 ................................... 14105097 ................................... 14105098 ................................... 14105099 ................................... 14105481 ................................... 14205482 ................................... 14205483 ................................... 14205484 ................................... 14205485 ................................... 14205486 ................................... 14205487 ................................... 14205488 ................................... 14205489 ................................... 14205581 ................................... 14205582 ................................... 14205583 ................................... 14205584 ................................... 14205585 ................................... 14205586 ................................... 14205587 ................................... 14205588 ................................... 14205589 ................................... 14205782 ................................... 14305783 ................................... 14305784 ................................... 14305785 ................................... 14305786 ................................... 14305788 ................................... 14323804-18-01 ........................ 14023805-18-01 ........................ 14023807-18-01 ........................ 14023810-18-01 ........................ 14023815-60-01 ........................ 14023817-60-01 ........................ 14023824-60-01 ........................ 14023825-60-01 ........................ 14023827-60-01 ........................ 14076502 ....................................... 576512 ....................................... 576812 ....................................... 5

76822 ....................................... 576832 ....................................... 576843 ....................................... 576954 ....................................... 676994 ....................................... 6395011 ................................... 92395011-3 ............................... 93395011-4 ............................... 93395011-5 ............................... 93395025 ................................. 106395025-3 ............................. 107395025-4 ............................. 107395025-5 ............................. 107395025-10 ........................... 107395027 ................................. 110395029 ................................... 99395031-3 ............................. 107395031-5 ............................. 107395035-3 ............................. 108395035-4 ............................. 108395035-5 ............................. 108395058 ................................... 99397001 ................................... 95495015 ................................... 99495016 ................................... 99495023 ................................. 106495025 ................................... 92495027 ................................... 99495028 ................................. 105495035 ................................... 92495036 ................................... 92497001 ................................... 95574608 ................................. 176710010 ................................. 163710011 ................................. 163710017 ................................. 163710018 ................................. 163710021 ................................. 163710022 ................................. 163710023 ................................. 163710024 ................................. 163740002 ................................. 158740004 ................................. 158740102 ................................. 158740104 ................................. 158740202 ................................. 158740204 ................................. 158740302 ................................. 158740304 ................................. 158

740501 ................................. 167740504 ................................. 167740508 ................................. 167740512 ................................. 167740516 ................................. 167740520 ................................. 167740528 ................................. 167740542 ................................. 167740552 ................................. 167740601 ................................. 166740604 ................................. 166740608 ................................. 166740612 ................................. 166740616 ................................. 166740620 ................................. 166740701 ................................. 168740704 ................................. 168740706 ................................. 168740708 ................................. 168740709 ................................. 168740712 ................................. 168740716 ................................. 168740720 ................................. 168740728 ................................. 168740742 ................................. 168740752 ................................. 168742605 ................................. 177742608 ................................. 176743601 ................................. 169743602 ................................. 169743603 ................................. 169743604 ................................. 169743605 ................................. 169743701 ................................. 170743704 ................................. 170743705 ................................. 170743706 ................................. 170743707 ................................. 170810021 ................................. 163810022 ................................. 163810023 ................................. 163810024 ................................. 163C0431A .................................. 22C0432A .................................. 22C0433A .................................. 22C0434A .................................. 22C0435A .................................. 22C0436A .................................. 22C0437A .................................. 22

C0438A .................................. 22C0439A .................................. 22C0440A .................................. 22C0441A .................................. 22C0444A .................................. 22C0450A .................................. 32C0451A .................................. 32C0452A .................................. 32C0453A .................................. 32C0454A .................................. 32C0455A .................................. 32C0456A .................................. 32C0457A .................................. 32C0458A .................................. 32C0459A .................................. 32C0460A .................................. 32C0471 .................................. 125C0472 .................................. 126C0473 .................................. 125C0474 .................................. 126C0475 .................................. 126C0476 .................................. 126C0485 .................................. 125C0486 .................................. 125C0491 .................................. 125C0492 .................................. 125C0494 .................................. 126C0495 .................................. 126C0496 .................................. 126C0497 .................................. 126C0515A .................................. 78C0516A .................................. 78C0517A .................................. 78C0518A .................................. 78C0519A .................................. 78C0520A .................................. 78C0521A .................................. 78C0522A .................................. 78C0523A .................................. 78C0524A .................................. 78C0525A .................................. 78C0526A .................................. 78C0530A .................................. 72C0531A .................................. 72C0532A .................................. 72C0533A .................................. 72C0534A .................................. 72C0535A .................................. 72C0536A .................................. 72

Page 252: Cross-Reference & Online Spec Sheets - Datasheet Archive

241

Technical Information Electronics

CatalogNumber page

CatalogNumber page

CatalogNumber page

CatalogNumber page

Part Number Index

C0537A .................................. 72C0538A .................................. 72C0550A .................................. 66C0551A .................................. 66C0552A .................................. 66C0553A .................................. 66C0554A .................................. 66C0555A .................................. 66C0556A .................................. 66C0560A .................................. 66C0561A .................................. 66C0562A .................................. 66C0563A .................................. 66C0564A .................................. 66C0566A .................................. 66C0570A .................................. 65C0571A .................................. 65C0572A .................................. 65C0573A .................................. 65C0574A .................................. 65C0575A .................................. 65C0584A .................................. 65C0585A .................................. 65C0586A .................................. 65C0587A .................................. 65C0588A .................................. 65C0589A .................................. 65C0590A .................................. 65C0600A .................................. 73C0601A .................................. 73C0602A .................................. 73C0603A .................................. 73C0604A .................................. 73C0605A .................................. 73C0606A .................................. 73C0607A .................................. 73C0608A .................................. 73C0609A .................................. 73C0610A .................................. 73C0611A .................................. 73C0612A .................................. 73C0620A .................................. 75C0621A .................................. 75C0622A .................................. 75C0623A .................................. 75C0624A .................................. 75C0625A .................................. 75C0626A .................................. 75C0628A .................................. 75

C0630A .................................. 75C0650A .................................. 75C0651A .................................. 75C0652A .................................. 75C0653A .................................. 75C0654A .................................. 75C0655A .................................. 75C0656A .................................. 75C0658A .................................. 75C0660A .................................. 75C0663A .................................. 75C0680A .................................. 72C0681A .................................. 72C0682A .................................. 72C0683A .................................. 72C0684A .................................. 72C0685A .................................. 72C0686A .................................. 72C0687A .................................. 72C0688A .................................. 72C0720A .................................. 73C0721A .................................. 73C0722A .................................. 73C0723A .................................. 73C0724A .................................. 73C0725A .................................. 73C0726A .................................. 73C0728A .................................. 73C0729A .................................. 73C0730A .................................. 73C0740A .................................. 68C0741A .................................. 68C0742A .................................. 68C0743A .................................. 68C0744A .................................. 68C0745A .................................. 68C0746A .................................. 68C0747A .................................. 68C0748A .................................. 68C0749A .................................. 68C0750A .................................. 68C0751A .................................. 68C0753A .................................. 68C0754A .................................. 68C0755A .................................. 68C0760A .................................. 69C0761A .................................. 69C0762A .................................. 69C0763A .................................. 69

C0764A .................................. 69C0765A .................................. 69C0766A .................................. 69C0767A .................................. 69C0768A .................................. 69C0780A .................................. 69C0781A .................................. 69C0782A .................................. 69C0783A .................................. 69C0784A .................................. 69C0785A .................................. 69C0786A .................................. 69C0787A .................................. 69C0788A .................................. 69C0804A .................................. 79C0805A .................................. 79C0806A .................................. 79C0807A .................................. 79C0808A .................................. 79C0809A .................................. 79C0810A .................................. 79C0812A .................................. 79C0829A .................................. 77C0830A .................................. 77C0831A .................................. 77C0832A .................................. 77C0833A .................................. 77C0835A .................................. 77C0836A .................................. 77C0839A .................................. 77C0841A .................................. 76C0842A .................................. 76C0843A .................................. 76C0844A .................................. 76C0890A .................................. 74C0893A .................................. 74C0894A .................................. 74C0896A .................................. 74C0897A .................................. 74C0899A .................................. 74C0901A .................................. 74C0910A .................................. 83C0911A .................................. 83C0912A .................................. 83C0913A .................................. 83C0914A .................................. 83C0915A .................................. 83C0916A .................................. 83C0917A .................................. 83

C0924A .................................. 84C0925A .................................. 84C0926A .................................. 84C0939A .................................. 70C0940A .................................. 70C0941A .................................. 70C0942A .................................. 70C0943A .................................. 70C0944A .................................. 70C0945A .................................. 70C0946A .................................. 70C0947A .................................. 70C0948A .................................. 70C0951A .................................. 70C0952A .................................. 70C0953A .................................. 70C0954A .................................. 70C0955A .................................. 70C0956A .................................. 70C0957A .................................. 70C0958A .................................. 70C0959A .................................. 70C0960A .................................. 70C0961A .................................. 70C0971A .................................. 71C0972A .................................. 71C0973A .................................. 71C0974A .................................. 71C0975A .................................. 71C0976A .................................. 71C0977A .................................. 71C0978A .................................. 71C0979A .................................. 71C0980A .................................. 71C0981A .................................. 71C1000A ................................ 154C1001A ................................ 154C1002A ................................ 154C1003A ................................ 154C1004A ................................ 154C1005A ................................ 154C1102 .................................. 101C1103 .................................. 101C1104 .................................. 101C1106 .................................. 101C1108A .................................. 94C1110 .................................. 102C1112 .................................. 102C1117 .................................. 100

Page 253: Cross-Reference & Online Spec Sheets - Datasheet Archive

242

Electronics Technical Information

CatalogNumber page

CatalogNumber page

CatalogNumber page

CatalogNumber page

CapacitanceCharacteristic Impedance

≤53.2 pF/m • 16.2 pF/ft75 r/Ohms

Attenuation (dB/100 ft)Velocity of Propagation

0.21@ 1 MHz • 6.04 dB @ 1000MHz83% riser

Part Number Index

C1118 .................................. 139C1119 .................................. 139C1123 .................................. 139C1124 .................................. 139C1126 .................................. 139C1130 .................................. 139C1135 .................................. 101C1142 .................................. 101C1154 .................................... 94C1155 .................................. 100C1156 .................................. 110C1158 .................................. 105C1160 .................................... 96C1162 .................................. 109C1164 .................................. 109C1166 .................................. 100C1176A ................................ 111C1178 .................................. 100C1180 .................................... 94C1188 .................................. 100C1198 .................................... 94C1201 .................................. 175C1202 ............................ 41, 175C1203 .................................... 41C1204 .................................... 41C1206 .................................... 41C1208 .................................... 41C1210 .................................... 41C1212 .................................... 41C1226A ................................ 173C1228A ................................ 171C1300 .................................. 172C1301 .................................. 172C1302 ............................ 40, 172C1304 .................................... 40C1305 .................................... 40C1308 .................................... 40C1310 .................................... 40C1312 .................................... 40C1313 .................................... 40C1318 ...................................... 7C1319 ...................................... 7C1320A .................................... 7C1321 ...................................... 7C1322A ................................ 174C1326 ...................................... 7C1331A ................................ 160C1332A .................................. 36C1333A ................................ 159

C1335A .................................. 33C1337A .................................. 33C1338A ................................ 161C1340A ................................ 160C1341A .................................. 33C1343A ................................ 160C1345A ................................ 159C1350A .................................. 60C1352A .................................. 58C1353A .................................. 58C1356 .................................. 156C1357 .................................. 156C1358 .................................. 156C1360 .................................. 156C1361 .................................. 156C1362 .................................. 156C1363 .................................. 156C1364 .................................. 157C1368A .................................. 80C1458.15.90 ........................ 151C1458.55.90 ........................ 151C1458.56.90 ........................ 151C1458.57.90 ........................ 151C1461.15.90 ........................ 151C1461.55.90 ........................ 151C1461.56.90 ........................ 151C1461.57.90 ........................ 151C1463.15.90 ........................ 151C1463.55.90 ........................ 151C1463.56.90 ........................ 151C1558.15.92 ........................ 155C1561.15.92 ........................ 155C1563.15.92 ........................ 155C1602 ............................ 41, 175C1603 .................................... 41C1604 .................................... 41C1606 .................................... 41C1608 .................................... 41C1612 .................................... 41C1614 .................................... 41C1642A .................................. 35C1643A .................................. 35C1644A .................................. 35C1645A .................................. 35C1646A .................................. 35C1648A .................................. 38C1670A .................................. 46C1671A .................................. 46C1672A .................................. 46

C1673A .................................. 46C1676A .................................. 46C1700 .................................. 152C1701 .................................. 152C1702 .................................. 152C1703 .................................. 152C1704 .................................. 152C1705 .................................. 152C1800 .................................. 153C1801 .................................. 153C1802 .................................. 153C1803 .................................. 153C1804 .................................. 153C1805 .................................. 153C2003A .................................... 2C2004A .................................... 2C2015A .................................... 2C2016A .................................... 2C2028A .................................... 2C2040A .................................... 2C2052A .................................... 2C2053A .................................... 2C2064A .................................... 2C2065A .................................... 2C2100A .................................... 3C2101A .................................... 3C2102A .................................... 3C2103A .................................... 3C2104A .................................... 3C2105A .................................... 3C2106A .................................... 3C2107A .................................... 3C2117A .................................... 3C2118A .................................... 3C2119A .................................... 3C2404A .................................. 13C2405A .................................. 14C2406A .................................. 14C2409A .................................. 14C2410A .................................. 14C2412A .................................. 13C2420A .................................. 13C2421A .................................. 13C2422A .................................. 13C2423A .................................. 13C2424A .................................. 13C2425A .................................. 14C2426A .................................. 14C2427A .................................. 14

C2428A .................................. 14C2429A .................................. 14C2430A .................................. 14C2431A .................................. 14C2433A .................................. 13C2434A .................................. 14C2435A .................................. 14C2436A .................................. 14C2437A .................................. 14C2440A .................................. 14C2443A .................................. 14C2461A .................................. 11C2462A .................................. 11C2463A .................................. 11C2464A .................................. 11C2465A .................................. 11C2466A .................................. 11C2467A .................................. 11C2470A .................................. 11C2471A .................................. 11C2473A .................................. 11C2488A .................................. 11C2509A ................................ 164C2510A ................................ 164C2511A ................................ 164C2513A .................................. 23C2514A .................................. 23C2515A .................................. 23C2516A .................................. 23C2517A .................................. 23C2518A .................................. 24C2519A .................................. 24C2520A .................................. 24C2521A .................................. 24C2523A .................................. 23C2524A .................................. 23C2525A .................................. 23C2526A .................................. 23C2528A .................................. 23C2534A .................................. 23C2535A .................................. 23C2536A .................................. 23C2537A .................................. 23C2538A .................................. 23C2539A .................................. 23C2540A .................................. 23C2543A .................................. 25C2555A .................................. 23C2676A .................................. 34

Page 254: Cross-Reference & Online Spec Sheets - Datasheet Archive

243

Technical Information Electronics

CatalogNumber page

CatalogNumber page

CatalogNumber page

CatalogNumber page

Part Number Index

C2677A .................................. 34C2678A .................................. 36C2679A .................................. 36C2680A .................................. 36C2681A .................................. 36C2683A .................................. 36C2686A .................................. 36C2687A .................................. 36C2688A .................................. 36C2689A .................................. 36C2754A .................................... 9C2768A .................................. 33C2830A .................................. 13C2831A .................................. 13C2882A .................................. 33C2888A .................................. 33C2892A .................................. 33C2895A .................................. 33C3028 .................................... 56C3029 .................................... 56C3030 .................................... 56C3031 .................................... 56C3060 .................................... 28C3061 .................................... 28C3062 .................................... 28C3063 .................................... 28C3064 .................................... 28C3065 .................................... 28C3068 .................................... 28C3102 .................................... 16C3103 .................................... 16C3105 .................................... 16C3106 .................................... 16C3110 .................................... 17C3111 .................................... 17C3112 .................................... 17C3113 .................................... 17C3114 .................................... 17C3115 .................................... 17C3116 .................................... 17C3117 .................................... 17C3118 .................................... 17C3119 .................................... 17C3120 .................................... 17C3121 .................................... 17C3122 .................................... 17C3123 .................................... 17C3124 .................................... 17C3125 .................................... 17

C3126 .................................... 16C3127 .................................... 17C3128 .................................... 17C3129 .................................... 17C3134 .................................... 16C3135 .................................... 16C3150 .................................... 48C3151 .................................... 48C3152 .................................... 48C3153 .................................... 48C3154 .................................... 27C3155 .................................... 27C3156 .................................... 61C3157 .................................... 61C3158 .................................... 28C3159 .................................... 28C3162 .................................... 27C3163 .................................... 27C3164 .................................... 27C3165 .................................... 48C3166 .................................... 27C3167 .................................. 128C3168 .................................. 128C3169 .................................... 27C3170 .................................. 128C3171 .................................. 128C3172 .................................. 128C3173 .................................. 128C3174 .................................. 128C3175 .................................. 128C3178 .................................... 16C3179 .................................... 16C3180 .................................... 27C3181 .................................... 27C3182 .................................... 27C3183 .................................... 28C3184 .................................... 28C3190 .................................... 16C3191 .................................... 16C3192 .................................... 16C3193 .................................... 16C3194 .................................... 16C3195 .................................... 16C3200 .................................. 122C3201 .................................. 122C3204 .................................... 48C3205 .................................... 48C3206 .................................... 48C3207 .................................... 48

C3208 .................................... 48C3210 .................................. 122C3211 .................................. 122C3214 .................................... 55C3215 .................................... 55C3216 .................................... 55C3217 .................................... 55C3218 .................................... 55C3220 .................................. 122C3223 .................................. 122C3224 .................................. 122C3225 .................................. 122C3240 .................................. 127C3241 .................................. 127C3242 .................................. 127C3243 .................................. 127C3244 .................................. 127C3245 .................................. 127C3246 .................................. 127C3247 .................................. 127C3260 .................................. 124C3261 .................................. 124C3270 .................................. 124C3271 .................................. 124C3280 .................................. 124C3282 .................................. 124C3283 .................................. 124C3284 .................................. 124C3310 .................................... 27C3311 .................................... 27C3320 .................................... 27C3321 .................................... 27C3322 .................................... 27C3340 .................................... 27C3341 .................................... 27C3352 .................................... 52C3353 .................................... 52C3354 .................................... 52C3356 .................................... 52C3362 .................................... 52C3364 .................................... 52C3500 .................................. 104C3519 .................................. 100C3520 .................................. 109C3521 .................................... 91C3523 .................................... 91C3524 .................................... 91C3525 .................................... 91C3526 .................................. 104

C3527 .................................. 104C3528 .................................... 97C3529 .................................... 98C3602 .................................... 21C3603 .................................... 21C3604 .................................... 21C3605 .................................... 21C3606 .................................... 21C3607 .................................... 21C3608 .................................... 21C3610 .................................... 21C4008A .............................. 9, 43C4010A .................................. 43C4014A .................................. 43C4015A .................................. 43C4017A .................................. 43C4062A .................................. 12C4063A .................................. 12C4064A .................................. 12C4065A .................................. 12C4066A .................................. 12C4067A .................................. 12C4070A .................................. 12C4071A .................................. 12C4073A .................................. 12C4075A .................................. 12C4076A .................................. 12C4077A .................................. 12C4078A .................................. 12C4079A .................................. 12C4080 .................................. 139C4081A .................................. 10C4082A .................................. 10C4083A .................................. 10C4084A .................................. 10C4088A .................................. 12C4090 .................................. 139C4100A .................................. 18C4101A .................................. 18C4102A .................................. 18C4103A .................................. 18C4104A .................................. 18C4105A .................................. 18C4106A .................................. 18C4107A .................................. 18C4108A .................................. 18C4109A .................................. 18C4110A .................................. 18C4111A .................................. 18

Page 255: Cross-Reference & Online Spec Sheets - Datasheet Archive

244

Electronics Technical Information

CatalogNumber page

CatalogNumber page

CatalogNumber page

CatalogNumber page

Part Number Index

C4112A .................................. 18C4113A .................................. 18C4114A .................................. 18C4115A .................................. 18C4116A .................................. 18C4117A .................................. 19C4118A .................................. 19C4119A .................................. 19C4120A .................................. 19C4121A .................................. 19C4122A .................................. 19C4123A .................................. 19C4124A .................................. 19C4125A .................................. 19C4126A .................................. 19C4127A .................................. 19C4128A .................................. 19C4129A .................................. 19C4130A .................................. 19C4131A .................................. 19C4132A .................................. 19C4133A .................................. 19C4134A .................................. 19C4135A .................................. 20C4136A .................................. 20C4137A .................................. 20C4138A .................................. 20C4139A .................................. 20C4140A .................................. 20C4141A .................................. 20C4142A .................................. 20C4143A .................................. 20C4144A .................................. 20C4145A .................................. 20C4146A .................................. 20C4147A .................................. 20C4148A .................................. 20C4149A .................................. 20C4150A .................................. 20C4151A .................................. 20C4152A .................................. 29C4153A .................................. 29C4154A .................................. 29C4155A .................................. 29C4156A .................................. 29C4157A .................................. 29C4158A .................................. 29C4159A .................................. 29C4160A .................................. 29

C4161A .................................. 29C4162A .................................. 29C4163A .................................. 29C4164A .................................. 29C4165A .................................. 29C4166A .................................. 30C4167A .................................. 29C4168A .................................. 29C4169A .................................. 29C4170A .................................. 53C4171A .................................. 53C4172A .................................. 53C4173A .................................. 53C4174A .................................. 53C4175A .................................. 53C4176A .................................. 53C4177A .................................. 53C4178A .................................. 53C4179A .................................. 53C4180A .................................. 53C4181A .................................. 53C4182A .................................. 53C4183A .................................. 54C4184A .................................. 54C4185A .................................. 54C4186A .................................. 54C4187A .................................. 54C4188A .................................. 54C4189A .................................. 54C4190A .................................. 54C4191A .................................. 53C4192A .................................. 30C4193A .................................. 30C4194A .................................. 30C4195A .................................. 30C4196A .................................. 30C4197A .................................. 30C4198A .................................. 30C4199A .................................. 30C4200A .................................. 30C4201A .................................. 30C4202A .................................. 30C4203A .................................. 59C4204A .................................. 30C4205A .................................. 30C4206A .................................. 19C4207A .................................. 30C4208A .................................. 30C4209A .................................. 53

C4210A .................................. 30C4211A .................................. 30C4212A .................................. 30C4213A .................................. 30C4214A .................................. 19C4215A .................................. 30C4216A .................................. 31C4217A .................................. 31C4218A .................................. 31C4219A .................................. 31C4220A .................................. 31C4221A .................................. 31C4222A .................................. 31C4223A .................................. 31C4224A .................................. 31C4225A .................................. 31C4226A .................................. 31C4227A .................................. 31C4228A .................................. 31C4229A .................................. 31C4230A .................................. 31C4300A ................................ 118C4301A ................................ 118C4302A ................................ 118C4304A ................................ 118C4305A ................................ 118C4306A ................................ 118C4307A ................................ 118C4308A ................................ 118C4309A ................................ 118C4310A ................................ 118C4311A .................................... 9C4312A ................................ 118C4313A ................................ 118C4314A ................................ 118C4315A ................................ 118C4316A ................................ 118C4317A ................................ 118C4318A ................................ 118C4321A ................................ 118C4322A ................................ 118C4323A ................................ 118C4324A ................................ 118C4325A ................................ 118C4326A ................................ 118C4327A ................................ 118C4328A ................................ 129C4329A ................................ 129C4330A ................................ 129

C4331A ................................ 129C4332A ................................ 129C4333A ................................ 129C4334A ................................ 120C4335A ................................ 120C4336A ................................ 120C4337A ................................ 120C4338A ................................ 120C4339A ................................ 120C4340A ................................ 120C4341A ................................ 120C4342A ................................ 120C4343A ................................ 120C4344A ................................ 120C4345A ................................ 120C4346A ................................ 120C4347A ................................ 120C4348A ................................ 120C4349A ................................ 118C4350A ................................ 120C4408 .................................. 138C4408ST .............................. 138C4410 .................................. 138C4412 .................................. 138C4412ST .............................. 138C4413 .................................. 138C4841A .................................. 76C4842A .................................. 76C4843A .................................. 76C4844A .................................. 76C5011 .................................... 96C5025 .................................... 96C5029 .................................... 96C5034 .................................... 96C5039 .................................... 97C5043 .................................... 98C5044 .................................... 97C5076 .................................. 139C5078 .................................. 139C5084 .................................. 139C5086 .................................. 139C5096 .................................. 139C5460 .................................. 139C5760 .................................... 88C5761 .................................... 88C5770 .................................. 103C5775 .................................... 88C5776 .................................... 88C5777 .................................... 89

Page 256: Cross-Reference & Online Spec Sheets - Datasheet Archive

245

Technical Information Electronics

CatalogNumber page

CatalogNumber page

CatalogNumber page

CatalogNumber page

Part Number Index

C5778 .................................... 91C5780 .................................. 103C5784 .................................. 103C5785 .................................... 89C5802 .................................... 89C5804 .................................... 89C5814 .................................... 90C5822 .................................... 90C5830 .................................. 103C5886 .................................... 88C5889 .................................... 89C6010A .................................. 43C6014A .................................. 43C6015A .................................. 43C6017A .................................. 43C6019A .................................. 43C6023A .................................. 43C6026A .................................. 43C6035A .................................. 81C6036A .................................. 81C6040A .................................. 82C6041A .................................. 82C6042A .................................. 82C6043A .................................. 82C6044A .................................. 82C6045A .................................. 82C6046A .................................. 82C6047A .................................. 82C6048A .................................. 82C6049A .................................. 82C6050A .................................. 82C6051A .................................. 82C6052A .................................. 82C6053A .................................. 82C6054A .................................. 82C6056A .................................. 82C6058A .................................. 82C6059A .................................. 82C6060A .................................. 82C6061A ................................ 165C6062A ................................ 165C6065A .................................. 82C6066A .................................. 82C6067A .................................. 82C6101A .................................. 44C6103A .................................. 44C6106A .................................. 44C6109A .................................. 44C6111A .................................. 44

C6118A .................................. 44C6119A .................................. 44C6120A .................................. 44C6121A .................................. 44C6310 .................................. 138C6311 .................................. 138C6312 .................................. 138C6313 .................................. 138C6348A .................................. 12C6351A .................................. 13C6352A .................................. 13C6353A .................................. 13C6355A .................................. 13C6356A .................................. 13C6357A .................................. 13C6358A .................................. 13C6360A .................................. 13C6367 .................................. 157C6451A .................................. 47C6500A .................................. 37C6501A .................................. 37C6502A .................................. 37C6503A .................................. 37C6504A .................................. 37C6505A .................................. 37C6506A .................................. 37C6507A .................................. 37C6508A .................................. 37C7102A ................................ 156C7104A .................................. 46C7106A .................................. 58C7108A .................................... 7C7112A .................................. 66C7114A .................................. 66C7116A .................................. 66C7600A .................................... 4C7602A .................................... 4C7604A .................................... 4C7606A .................................... 4C7608A .................................... 4C7610A .................................... 4C7611A .................................... 4C8000 .................................. 112C8001 .................................. 112C8014 .................................. 112C8025 .................................. 102C8027 .................................. 104C8028 .................................. 104C8029 .................................... 91

C8030 .................................. 101C8031 .................................... 91C8101 .................................... 49C8102 .................................... 15C8103 .................................... 49C8104 .................................... 49C8105 .................................... 62C8106 .................................... 26C8107 .................................... 39C8108 .................................... 39C8109 .................................... 49C8110 .................................... 39C8111 .................................... 39C8112 .................................... 63C8113 .................................... 51C8114 .................................... 26C8115 .................................... 39C8116 .................................... 45C8117 .................................... 57C8118 .................................... 50C8119 .................................... 39C8120 .................................... 39C8122 .................................... 45C8123 .................................... 51C8124 .................................... 51C8125 .................................. 185C8126 .................................... 51C8127 .................................... 51C8128 .................................... 64C8129 .................................... 57C8131 .................................... 62C8132 .................................... 63C8133 .................................... 62C8134 .................................... 62CP5.30.02 ............................ 145CP5.30.03 ............................ 145CP5.30.05 ............................ 145CP5.30.06 ............................ 145CP5.30.07 ............................ 145CP5.30.10 ............................ 145CP5.A3.02 ............................ 145CP5.A3.03 ............................ 145CP5.A3.05 ............................ 145CP5.A3.06 ............................ 145CP5.A3.07 ............................ 145CP5.A3.10 ............................ 145CP6.30.02 ............................ 144CP6.30.03 ............................ 144CP6.30.05 ............................ 144

CP6.30.06 ............................ 144CP6.30.07 ............................ 144CP6.30.10 ............................ 144CP6.A3.02 ............................ 144CP6.A3.03 ............................ 144CP6.A3.05 ............................ 144CP6.A3.06 ............................ 144CP6.A3.07 ............................ 144CP6.A3.10 ............................ 144CR5.30.02 ............................ 145CR5.30.03 ............................ 145CR5.30.05 ............................ 145CR5.30.06 ............................ 145CR5.30.07 ............................ 145CR5.30.10 ............................ 145CR5.A3.02 ............................ 145CR5.A3.03 ............................ 145CR5.A3.05 ............................ 145CR5.A3.06 ............................ 145CR5.A3.07 ............................ 145CR5.A3.10 ............................ 145CR6.30.02 ............................ 144CR6.30.03 ............................ 144CR6.30.05 ............................ 144CR6.30.06 ............................ 144CR6.30.07 ............................ 144CR6.30.10 ............................ 144CR6.A3.02 ............................ 144CR6.A3.03 ............................ 144CR6.A3.05 ............................ 144CR6.A3.06 ............................ 144CR6.A3.07 ............................ 144CR6.A3.10 ............................ 144E1000S ................................. 134E1001S ................................. 134E1002S ................................. 134E1003S ................................. 134E1004S ................................. 134E1006S ................................. 134E1008S ................................. 134E1010S ................................. 134E1012S ................................. 134E1022S ................................. 134E1023S ................................. 134E1024S ................................. 134E1030S ................................. 134E1032S ................................. 134E1033S ................................. 134E1034S ................................. 134

Page 257: Cross-Reference & Online Spec Sheets - Datasheet Archive

246

Electronics Technical Information

CatalogNumber page

CatalogNumber page

CatalogNumber page

CatalogNumber page

Part Number Index

E1036S ................................. 134E1038S ................................. 134E1040S ................................. 134E1041S ................................. 134E1042S ................................. 134E1043S ................................. 134E1044S ................................. 134E1052S ................................. 134E1054S ................................. 134E1062S ................................. 134E1064S ................................. 134E1482S ................................. 117E1484S ................................. 117E1486S ................................. 117E1502S ................................. 117E1503S ................................. 117E1504S ................................. 117E1505S ................................. 117E1506S ................................. 117E1508S ................................. 117E1512S ................................. 117E1514S ................................. 117E1522S ................................. 117E1524S ................................. 117E1532S ................................. 117E1534S ................................. 117E1842S ................................. 162E1843S ................................. 162E2000S ................................. 135E2002S ................................. 135E2003S ................................. 135E2004S ................................. 135E2006S ................................. 135E2008S ................................. 135E2010S ................................. 135E2012S ................................. 135E2022S ................................. 135E2023S ................................. 135E2024S ................................. 135E2030S ................................. 135

E2032S ................................. 135E2033S ................................. 135E2034S ................................. 135E2036S ................................. 135E2038S ................................. 135E2040S ................................. 135E2041S ................................. 135E2042S ................................. 135E2043S ................................. 135E2044S ................................. 135E2052S ................................. 135E2054S ................................. 135E2062S ................................. 135E2064S ................................. 135E2100S ................................. 137E2102S ................................. 137E2103S ................................. 137E2104S ................................. 137E2106S ................................. 137E2108S ................................. 137E2122S ................................. 137E2123S ................................. 137E2124S ................................. 137E2200S ................................. 137E2202S ................................. 137E2203S ................................. 137E2204S ................................. 137E2206S ................................. 137E2208S ................................. 137E2242S ................................. 137E2243S ................................. 137E2244S ................................. 137E2252S ................................. 137E2254S ................................. 137E2262S ................................. 137E2264S ................................. 137E2402S ................................. 117E2404S ................................. 117E2406S ................................. 117E2482S ................................. 119

E2484S ................................. 119E2502S ................................. 119E2503S ................................. 119E2504S ................................. 119E2506S ................................. 119E2508S ................................. 119E2522S ................................. 119E2524S ................................. 119E2532S ................................. 119E2534S ................................. 119E2542S ................................. 119E2544S ................................. 119E3000S ................................. 136E3001S ................................. 136E3002S ................................. 136E3003S ................................. 136E3004S ................................. 136E3006S ................................. 136E3008S ................................. 136E3010S ................................. 136E3012S ................................. 136E3022S ................................. 136E3023S ................................. 136E3024S ................................. 136E3030S ................................. 136E3032S ................................. 136E3033S ................................. 136E3034S ................................. 136E3036S ................................. 136E3038S ................................. 136E3042S ................................. 136E3043S ................................. 136E3044S ................................. 136E3052S ................................. 136E3054S ................................. 136E3062S ................................. 136E3064S ................................. 136E3482S ................................. 121E3484S ................................. 121E3502S ................................. 121

E3503S ................................. 121E3504S ................................. 121E3506S ................................. 121E3512S ................................. 121E3514S ................................. 121E3522S ................................. 121E3524S ................................. 121E3532S ................................. 121E3534S ................................. 121E3542S ................................. 123E3602S ................................. 123E3603S ................................. 123E3604S ................................. 123E3606S ................................. 123E3612S ................................. 123E3614S ................................. 123E3622S ................................. 123E3624S ................................. 123E3632S ................................. 123E3634S ................................. 123E3842S ................................. 162E3843S ................................. 162EO24C0045510 .................... 184EO26C0045510 .................... 184EO28C0045510 .................... 184EO28P0181510 .................... 184EO28P0501510 .................... 184EO30C0045510 .................... 184SP00C0011010 .................... 182SP00C0012010 .................... 182Z028C0061110 .................... 183Z028C0066110 .................... 184ZO28C0042010 .................... 184ZO28C0042210 .................... 184ZO28C0042410 .................... 184ZO28C0042610 .................... 184ZO28C0042810 .................... 184ZO28C0101120 .................... 184