Page 1654 Mar 2008 Siemens ITS CPU 317F-2 PN/DP Function Password protection; a password concept protects the user program from unauthorized access. Diagnostics buffer; the last 500 error and interrupt events are stored in a buffer for diagnostic purposes. Maintenance-free data backup; all data is automatically backed up by the CPU if the voltage is interrupted and is available unchanged after the voltage has been reconnected. Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can beparameterized using STEP 7: Multi-Point Interface (MPI); determination of node addresses. Start-up/cycle time behavior; definition of maximum cycle time and loading. Clock memory; setting of addresses. Protection level; definition of access rights for program and data. System diagnostics; definition of handling and scope of diagnostic messages. Watchdog interrupts; setting of periodicity.

CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Embed Size (px)

Citation preview

Page 1: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1654 Mar 2008 Siemens ITS

CPU 317F-2 PN/DP

Function

Password protection;a password concept protects the user program from unauthorized access.

Diagnostics buffer;the last 500 error and interrupt events are stored in a buffer for diagnostic purposes.

Maintenance-free data backup;all data is automatically backed up by the CPU if the voltage is interrupted and is available unchanged after thevoltage has been reconnected.

Parameterizable propertiesThe S7 configuration as well as the properties and response of the CPUs can beparameterized using STEP 7:

Multi-Point Interface (MPI);determination of node addresses.

Start-up/cycle time behavior;definition of maximum cycle time and loading.

Clock memory;setting of addresses.

Protection level;definition of access rights for program and data.

System diagnostics;definition of handling and scope of diagnostic messages.

Watchdog interrupts;setting of periodicity.

Page 2: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1655 Mar 2008 Siemens ITS

Time-of-day interrupts;setting of start date, start time, and periodicity.

PROFIBUS DP master/slave interface;user-oriented address allocation for distributed I/O.

Display and information functions Status and error indications;

LEDs indicate hardware, programming, time, I/O or bus errors and operating statuses such as RUN, STOP,start-up.

Test functions;the PG is used to indicate signal status during program execution, to modify process variables independentlyof the user program and to output the contents of stack memories.

Information functions;the PG can be used to obtain information about the memory capacity and operating mode of the CPU, thecurrent loading of the work and load memory, current cycle times and diagnostics buffer content in plaintext.

Integrated communication functions PG/OP communication Global data communication S7 basic communication S7 communication Open communication by means of TCP/IP PROFINET CBA Web server Data record routing

Page 3: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1656 Mar 2008 Siemens ITS

CommunicationSafety-oriented and standard communication between the central controller and distributed stations takes place overPROFIBUS DP and/or PROFINET. The specially developed PROFIsafe profile supports the transfer of user datafor the safety functions within the standard data message frame. Additional hardware components, e.g. specialsafety buses are not required. The necessary software is either integrated in the hardware components as anexpansion of the operating system or loaded into the CPU later as a certified software block.

Mode of operationThe safety functions of the F-CPU are included in the F program of the CPU and in the fail-safe signal modules.The signal modules monitor the output and input signals by means of discrepancy analysis and the injection of testsignals. The CPU checks the proper operation of the controller by means of periodic self-tests, command tests andlogic-based and time-based program execution checks. Furthermore, the I/O is checked using requests for signs oflife.If an error is diagnosed in the system, the system will be placed in a safe state. An F runtime license is notrequired to operate the CPU 317F-2 PN/DP.

ProgrammingThe CPU 317F-2 PN/DP is programmed in the same manner as the other SIMATIC S7 systems. The user programfor non-fail-safe plant units is created using tried and tested programming tools, e.g. STEP 7. SIMATIC S7Distributed Safety option package The STEP 7 option package "SIMATIC S7 Distributed Safety" is required forprogramming the safety-related program components. The package contains all the functions and blocks required tocreate an F program. The F program with the safety functions is connected in F FBD or F LAD or using specialfunction blocks from the F library. Use of F FBD or F LAD simplifies configuration and programming of thesystem and also acceptance testing thanks to the cross-system uniform presentation form. The programmer canconcentrate on configuration of the safety-related application without the need to use additional tools.

Technical specifications

Page 4: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1657 Mar 2008 Siemens ITS

Technical specifications

6ES7 317-2FK14-0AB0Product versionHardware product version 01Firmware version V3.2General informationassociated programming package STEP 7 V 5.5 or higher, Distributed Safety

V 5.4 SP4Supply voltage24 V DC YesInput currentCurrent consumption (rated value) 750 mACurrent consumption (in no-load operation),typ.

150 mA

Page 5: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1658 Mar 2008 Siemens ITS

Inrush current, typ. 4 AI²t 1 A²·sPower lossesPower loss, typ. 4.65 WMemoryWork memory•integrated 1 536 Kibyte•expandable No•Size of retentive memory for retentive datablocks

256 Kibyte

Load memory•pluggable (MMC) Yes•pluggable (MMC), max. 8 Mbyte•Data management on MMC (after lastprogramming), min.

10 a

Backup•present Yes; Guaranteed by MMC (maintenance-

free)•without battery Yes; Program and dataCPU-blocksNumber of blocks (total) 2 048; (DBs, FCs, FBs); the maximum

number of loadable blocks can be reducedby the MMC used.

DB

Page 6: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1659 Mar 2008 Siemens ITS

•Number, max. 2 048; Number range: 1 to 16000•Size, max. 64 KibyteFB•Number, max. 2 048; Number range: 0 to 7999•Size, max. 64 KibyteFC•Number, max. 2 048; Number range: 0 to 7999•Size, max. 64 KibyteOB•Size, max. 64 KibyteNesting depth•per priority class 16•additional within an error OB 4CPU processing timesfor bit operations, min. 0.025 µsfor word operations, min. 0.03 µsfor fixed point arithmetic, min. 0.04 µsfor floating point arithmetic, min. 0.16 µsCounters, timers and their retentivityS7 counter•Number 512•Retentivity

• adjustableYes

Page 7: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1660 Mar 2008 Siemens ITS

• lower limit0

• upper limit511

• presetZ 0 to Z 7

•Counting range

• adjustableYes

• lower limit0

• upper limit999

IEC counter•present Yes•Type SFB•Number Unlimited (limited only by RAM capacity)S7 times•Number 512•Retentivity

• adjustableYes

• lower limit0

Page 8: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1661 Mar 2008 Siemens ITS

• upper limit511

• presetNo retentivity

•Time range

• lower limit10 ms

• upper limit9 990 s

IEC timer•present Yes•Type SFB•Number Unlimited (limited only by RAM capacity)Data areas and their retentivityretentive data area, total All, max. 256 KBFlag•Number, max. 4 096 byte•Retentivity available Yes; MB 0 to MB 4095•Retentivity preset MB 0 to MB 15•Number of clock memories 8; 1 memory byteData blocks•Retentivity adjustable Yes; via non-retain property on DB•Retentivity preset YesLocal data

Page 9: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1662 Mar 2008 Siemens ITS

•per priority class, max. 32 768 byte; Max. 2048 bytes per blockAddress areaI/O address area•Inputs 8 192 byte•Outputs 8 192 byte•of which, distributed

• Inputs8 192 byte

• Outputs8 192 byte

Process image•Inputs, adjustable 8 192 byte•Outputs, adjustable 8 192 byte•Inputs, default 256 byte•Outputs, default 256 byteSubprocess images•Number of subprocess images, max. 1; With PROFINET IO, the length of the

user data is limited to 1600 bytesDigital channels•Inputs 65 536•Outputs 65 536•Inputs, of which central 1 024•Outputs, of which central 1 024Analog channels

Page 10: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1663 Mar 2008 Siemens ITS

•Inputs 4 096•Outputs 4 096•Inputs, of which central 256•Outputs, of which central 256Hardware configurationRacks, max. 4Modules per rack, max. 8Expansion devices, max. 3Number of DP masters•integrated 1•via CP 4Number of operable FMs and CPs(recommended)•FM 8•CP, point-to-point 8•CP, LAN 10Time of dayClock•Hardware clock (real-time clock) Yes•battery-backed and synchronizable Yes•Deviation per day, max. 10 s; Typ.: 2 s•Backup time 6 wk; At 40 °C ambient temperature•Behavior of the clock following POWER-ON

Clock continues running after POWEROFF

Page 11: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1664 Mar 2008 Siemens ITS

•Behavior of the clock following expiry ofbackup period

Clock continues to run with the time atwhich the power failure occurred

Operating hours counter•Number 4•Number/Number range 0 to 3•Range of values 0 to 2^31 hours (when using SFC 101)•Granularity 1 hour•retentive Yes; Must be restarted at each restartClock synchronization•supported Yes•to MPI, master Yes•to MPI, slave Yes•to DP, master Yes; With DP slave only slave clock•to DP, slave Yes•in AS, master Yes•in AS, slave Yes•on Ethernet via NTP Yes; as client1st interfaceType of interface Integrated RS 485 interfacePhysics RS 485Isolated YesPower supply to interface (15 to 30 V DC),max.

200 mA

Functionality

Page 12: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1665 Mar 2008 Siemens ITS

•MPI Yes•DP master Yes•DP slave Yes•Point-to-point connection NoMPI•Services

• PG/OP communicationYes

• RoutingYes

• Global data communicationYes

• S7 basic communicationYes

• S7 communicationYes

• S7 communication, as clientNo; but via CP and loadable FB

• S7 communication, as serverYes

•Transmission rate, max. 12 Mbit/sDP master•Services

Yes

Page 13: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1666 Mar 2008 Siemens ITS

• PG/OP communication

• Global data communicationNo

• S7 basic communicationYes; I blocks only

• S7 communicationYes

• S7 communication, as clientNo

• S7 communication, as serverYes

• Equidistance mode supportYes

• Isochronous modeYes; OB 61; isochronous mode can onlybe used alternatively on PROFIBUS DP orPROFINET IO

• SYNC/FREEZEYes

• Activation/deactivation of DP slavesYes

• Number of DP slaves that can besimultaneously activated/deactivated,max.

8

Page 14: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1667 Mar 2008 Siemens ITS

• Direct data exchange (slave-to-slavecommunication)

Yes; As subscriber

• DPV1Yes

•Transmission rate, max. 12 Mbit/s•Number of DP slaves, max. 124•Address area

• Inputs, max.8 Kibyte

• Outputs, max.8 Kibyte

•User data per DP slave

• Inputs, max.244 byte

• Outputs, max.244 byte

DP slave•Services

• PG/OP communicationYes

• Global data communicationNo

No

Page 15: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1668 Mar 2008 Siemens ITS

• S7 basic communication

• S7 communicationYes

• S7 communication, as clientNo

• S7 communication, as serverYes; Connection configured on one sideonly

• Direct data exchange (slave-to-slavecommunication)

Yes

• DPV1No

•Transmission rate, max. 12 Mbit/s•Automatic baud rate search Yes; only with passive interface•Transfer memory

• Inputs244 byte

• Outputs244 byte

•Address area, max. 32•User data per address area, max. 32 byte2nd interfaceType of interface PROFINETPhysics Ethernet RJ45

Page 16: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1669 Mar 2008 Siemens ITS

Isolated YesIntegrated switch YesNumber of ports 2Automatic detection of transmission speed Yes; 10/100 Mbit/sAutonegotiation YesAutocrossing YesMedia redundancy•supported Yes•Switchover time on line break, typically 200 ms; PROFINET MRP•Number of stations in the ring, max. 50Change of IP address at runtime, supported YesFunctionality•MPI No•DP master No•DP slave No•PROFINET IO Controller Yes; Also simultaneously with IO-Device

functionality•PROFINET IO Device Yes; Also simultaneously with IO

Controller functionality•PROFINET CBA YesPROFINET IO Controller•Services

• PG/OP communicationYes

Page 17: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1670 Mar 2008 Siemens ITS

• S7 communicationYes; with loadable FBs, max. configurableconnections: 16, max. number of instances:32

• Isochronous modeYes; OB 61; isochronous mode can onlybe used alternatively on PROFIBUS DP orPROFINET IO

• Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP

•Transmission rate, max. 100 Mbit/s•Number of connectable IO devices, max. 128•Max. number of connectable IO devices forRT

128

• of which in line, max.128

•Number of IO devices with IRT and theoption "high flexibility"

128

• of which in line, max.61

•Number of IO Devices with IRT and theoption "high performance", max.

64

• of which in line, max.64

•IRT, supported Yes•Shared device, supported Yes

Page 18: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1671 Mar 2008 Siemens ITS

•Prioritized startup supported Yes

• Number of IO Devices, max.32

•Activation/deactivation of IO Devices Yes

• Number of IO Devices that can besimultaneously activated/deactivated,max.

8

•IO Devices changing during operation(partner ports), supported

Yes

• Max. number of IO devices per tool8

•Device replacement without swap medium Yes•Send cycles 250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in

the case of IRT with "high flexibility"option)

•Updating time 250 µs to 512 ms (depending on theoperating mode, see Manual "S7-300 CPU31xC and CPU 31x, Technical Data" formore details)

•Address area

• Inputs, max.8 Kibyte

8 Kibyte

Page 19: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1672 Mar 2008 Siemens ITS

• Outputs, max.•User data per address area, max.

• User data consistency, max.1 024 byte

PROFINET IO Device•Services

• PG/OP communicationYes

• S7 communicationYes; with loadable FBs, max. configurableconnections: 16, max. number of instances:32

• Isochronous modeNo

• Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP

• IRT, supportedYes

• PROFIenergy, supportedYes; With SFB 73 / 74 prepared forloadable PROFIenergy standard FB for I-Device

• Shared device, supportedYes

• Number of IO controllers with2

Page 20: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1673 Mar 2008 Siemens ITS

shared device, max.•Transfer memory

• Inputs, max.1 440 byte; Per IO Controller with shareddevice

• Outputs, max.1 440 byte; Per IO Controller with shareddevice

•Submodules

• Number, max.64

• User data per submodule, max.1 024 byte

Open IE communication•Open IE communication, supported Yes•Number of connections, max. 16•Local port numbers used at the system end 0, 20, 21, 25, 80, 102, 135, 161, 8080,

34962, 34963, 34964, 65532, 65533,65534, 65535

•Keep-alive function, supported YesCommunication functionsPG/OP communication YesData record routing YesGlobal data communication•supported Yes•Number of GD loops, max. 8

Page 21: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1674 Mar 2008 Siemens ITS

•Number of GD packets, max. 8•Number of GD packets, transmitter, max. 8•Number of GD packets, receiver, max. 8•Size of GD packets, max. 22 byte•Size of GD packet (of which consistent),max.

22 byte

S7 basic communication•supported Yes•User data per job, max. 76 byte•User data per job (of which consistent),max.

76 byte; 76 bytes (with X_SEND orX_RCV); 64 bytes (with X_PUT orX_GET as server)

S7 communication•supported Yes•as server Yes•as client Yes; via integrated PROFINET interface and

loadable FB or via CP and loadable FB•User data per job, max. See online help of STEP 7 (shared

parameters of the SFBs/FBs and of theSFCs/FCs of S7 Communication)

S5-compatible communication•supported Yes; via CP and loadable FCOpen IE communication•TCP/IP Yes; via integrated PROFINET interface and

Page 22: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1675 Mar 2008 Siemens ITS

loadable FBs

• Number of connections, max.16

• Data length for connection type01H, max.

1 460 byte

• Data length for connection type11H, max.

32 768 byte

• Several passive connections per port,supported

Yes

•ISO-on-TCP (RFC1006) Yes; via integrated PROFINET interface andloadable FBs

• Number of connections, max.16

• Data length, max.32 768 byte

•UDP Yes; via integrated PROFINET interface andloadable FBs

• Number of connections, max.16

• Data length, max.1 472 byte

Page 23: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1676 Mar 2008 Siemens ITS

Web server•supported Yes•Number of HTTP clients 5•User-defined websites YesPROFINET CBA (at set setpointcommunication load)•Setpoint for the CPU communication load 50 %•Number of remote interconnection partners 32•Number of functions, master/slave 30•Total of all Master/Slave connections 1 000•Data length of all incoming connectionsmaster/slave, max.

4 000 byte

•Data length of all outgoing connectionsmaster/slave, max.

4 000 byte

•Number of device-internal and PROFIBUSinterconnections

500

•Data length of device-internal undPROFIBUS interconnections, max.

4 000 byte

•Data length per connection, max. 1 400 byte•Remote interconnections with acyclictransmission

• Sampling frequency: Sampling time,min.

500 ms

Page 24: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1677 Mar 2008 Siemens ITS

• Number of incominginterconnections

100

• Number of outgoing interconnections100

• Data length of all incominginterconnections, max.

2 000 byte

• Data length of all outgoinginterconnections, max.

2 000 byte

• Data length per connection, max.1 400 byte

•Remote interconnections with cyclictransmission

• Transmission frequency:Transmission interval, min.

10 ms

• Number of incominginterconnections

200

• Number of outgoing interconnections200

2 000 byte

Page 25: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1678 Mar 2008 Siemens ITS

• Data length of all incominginterconnections, max.

• Data length of all outgoinginterconnections, max.

2 000 byte

• Data length per connection, max.450 byte

•HMI variables via PROFINET (acyclic)

• Number of stations that can log onfor HMI variables (PN OPC/iMap)

3; 2x PN OPC/1x iMap

• HMI variable updating500 ms

• Number of HMI variables200

• Data length of all HMI variables,max.

2 000 byte

•PROFIBUS proxy functionality

• supportedYes

• Number of linked PROFIBUSdevices

16

Page 26: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1679 Mar 2008 Siemens ITS

• Data length per connection, max.240 byte; Slave-dependent

Number of connections•Max. total number of instances 32•usable for routing X1 as MPI: max. 10; X1 as DP master:

max. 24; X1 as DP slave (active): max.14; X2 as PROFINET: 24 max.

S7 message functionsNumber of login stations for messagefunctions, max.

32; Depending on the configuredconnections for PG/OP and S7 basiccommunication

Process diagnostic messages Yessimultaneously active Alarm-S blocks, max. 300Test commissioning functionsStatus/control•Status/control variable Yes•Variables Inputs, outputs, memory bits, DB, times,

counters•Number of variables, max. 30•of which status variables, max. 30•of which control variables, max. 14Forcing•Forcing Yes•Force, variables Inputs, outputs

Page 27: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1680 Mar 2008 Siemens ITS

•Number of variables, max. 10Status block Yes; Up to 2 simultaneouslySingle step YesNumber of breakpoints 4Diagnostic buffer•present Yes•Number of entries, max. 500

• adjustableNo

• Of which powerfail-proof100; Only the last 100 entries are retained

•Number of entries readable in RUN, max. 499

• adjustableYes; From 10 to 499

• preset10

Isochronous modeIsochronous mode Yes; Via PROFIBUS DP or PROFINET

interfaceAmbient conditionsOperating temperature•Min. 0 °C•max. 60 °CConfiguration

Page 28: CPU 317F-2 PN/DP - GRAM Industrial: Automationgram.com.ph/wordpress2/wp-content/uploads/2013/05/CPU317F-2PN… · required to operate the CPU 317F-2 PN/DP. ... •Type SFB •Number

Page 1681 Mar 2008 Siemens ITS

programming•Programming language

• LADYes

• FBDYes

• STLYes

• SCLYes

• CFCYes

• GRAPHYes

• HiGraph®Yes

•Command set see instruction list•Nesting levels 8Know-how protection•User program protection/passwordprotection

Yes

•Block encryption Yes; With S7 block PrivacyDimensionsWidth 40 mm