Page 1626 Mar 2008 Siemens ITS CPU 315F-2 PN/DP Function Password protection; a password concept protects the user program from unauthorized access. Diagnostics buffer; the last 500 error and interrupt events are stored in a buffer for diagnostic purposes. Maintenance-free data backup; all data is automatically backed up by the CPU if the voltage is interrupted and is available unchanged after the voltage has been reconnected. Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7: Multi-Point Interface (MPI); determination of node addresses. Start-up/cycle time behavior; definition of maximum cycle time and loading. Clock memory; setting of addresses. Protection level; definition of access rights for program and data. System diagnostics; definition of handling and scope of diagnostic messages. Watchdog interrupts; setting of periodicity. Time-of-day interrupts; setting of start date, start time, and periodicity. PROFIBUS DP master/slave interface; user-oriented address allocation for distributed I/O.

CPU 315F-2 PN/DP - GRAM Industrial: Automation Philippinesgram.com.ph/.../wp-content/uploads/2013/05/SIPLUS-CPU-315F-2PN… · The CPU 315F-2 PN/DP is programmed in the same manner

Embed Size (px)

Citation preview

Page 1626 Mar 2008 Siemens ITS

CPU 315F-2 PN/DPFunction Password protection;

a password concept protects the user program from unauthorized access. Diagnostics buffer;

the last 500 error and interrupt events are stored in a buffer for diagnostic purposes. Maintenance-free data backup;

all data is automatically backed up by the CPU if the voltage is interrupted and is available unchanged after thevoltage has been reconnected.

Parameterizable propertiesThe S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7: Multi-Point Interface (MPI);

determination of node addresses. Start-up/cycle time behavior;

definition of maximum cycle time and loading. Clock memory;

setting of addresses. Protection level;

definition of access rights for program and data. System diagnostics;

definition of handling and scope of diagnostic messages. Watchdog interrupts;

setting of periodicity. Time-of-day interrupts;

setting of start date, start time, and periodicity. PROFIBUS DP master/slave interface; user-oriented address allocation for distributed I/O.

Page 1627 Mar 2008 Siemens ITS

Display and information functions

Status and error indications;LEDs indicate hardware, programming, time, I/O or bus errors and operating statuses such as RUN, STOP, start-up.

Test functions;the PG is used to indicate signal status during program execution, to modify process variables independently of theuser program and to output the contents of stack memories.

Information functions;the PG can be used to obtain information about the memory capacity and operating mode of the CPU, the currentloading of the work and load memory, current cycle times and diagnostics buffer content in plain text.

Integrated communication functions

PG/OP communication Global data communication S7 basic communication S7 communication Open communication by means of TCP/IP PROFINET CBA Web server Data record routing

Page 1628 Mar 2008 Siemens ITS

CommunicationSafety-oriented and standard communication between the central controller and distributed stations takes place overPROFIBUS DP and/or PROFINET. The specially developed PROFIsafe profile supports the transfer of user data for thesafety functions within the standard data message frame. Additional hardware components, e.g. special safety buses arenot required. The necessary software is either integrated in the hardware components as an expansion of the operatingsystem or loaded into the CPU later as a certified software block.

Mode of operationThe safety functions of the F-CPU are included in the F program of the CPU and in the fail-safe signal modules. Thesignal modules monitor the output and input signals by means of discrepancy analysis and the injection of test signals.The CPU checks the proper operation of the controller by means of periodic self-tests, command tests and logic-basedand time-based program execution checks. Furthermore, the I/O is checked using requests for signs of life. If an error isdiagnosed in the system, the system will be placed in a safe state. An F runtime license is not required to operate theCPU 319F-2 PN/DP.

ProgrammingThe CPU 315F-2 PN/DP is programmed in the same manner as the other SIMATIC S7 systems. The user program fornon-fail-safe plant sections is created using familiar programming tools, e.g. STEP 7.SIMATIC S7 Distributed Safety option package The STEP 7 option package "SIMATIC S7 Distributed Safety" isrequired for programming the safety-related program components. The package contains all the functions and blocksrequired to create an F program. The F program with the safety functions is connected in F FBD or F LAD or usingspecial function blocks from the F library. Use of F FBD or F LAD simplifies configuration and programming of thesystem and also acceptance testing thanks to the cross-system uniform presentation form. The programmer canconcentrate on configuration of the safety-related application without the need to use additional tools.

Technical specifications

Page 1629 Mar 2008 Siemens ITS

Technical specifications

6ES7 315-2FJ14-0AB0Product versionHardware product version 01Firmware version V3.2General informationassociated programming package STEP 7 V 5.5 or higher, Distributed

Safety V 5.4 SP4Supply voltage24 V DC YesInput currentCurrent consumption (rated value) 750 mA

Page 1630 Mar 2008 Siemens ITS

Current consumption (in no-load operation),typ.

150 mA

Inrush current, typ. 4 AI²t 1 A²·sPower lossesPower loss, typ. 4.65 WMemoryWork memory•integrated 512 Kibyte•expandable No•Size of retentive memory for retentive datablocks

128 Kibyte

Load memory•pluggable (MMC) Yes•pluggable (MMC), max. 8 Mbyte•Data management on MMC (after lastprogramming), min.

10 a

Backup•present Yes; Guaranteed by MMC (maintenance-

free)•without battery Yes; Program and dataCPU-blocksNumber of blocks (total) 1 024; (DBs, FCs, FBs); the maximum

number of loadable blocks can be reduced

Page 1631 Mar 2008 Siemens ITS

by the MMC used.DB•Number, max. 1 024; Number range: 1 to 16000•Size, max. 64 KibyteFB•Number, max. 1 024; Number range: 0 to 7999•Size, max. 64 KibyteFC•Number, max. 1 024; Number range: 0 to 7999•Size, max. 64 KibyteOB•Size, max. 64 KibyteNesting depth•per priority class 16•additional within an error OB 4CPU processing timesfor bit operations, min. 0.05 µsfor word operations, min. 0.09 µsfor fixed point arithmetic, min. 0.12 µsfor floating point arithmetic, min. 0.45 µsCounters, timers and their retentivityS7 counter•Number 256•Retentivity

Page 1632 Mar 2008 Siemens ITS

• adjustableYes

• lower limit0

• upper limit255

• presetZ 0 to Z 7

•Counting range

• adjustableYes

• lower limit0

• upper limit999

IEC counter•present Yes•Type SFB•Number Unlimited (limited only by RAM capacity)S7 times•Number 256•Retentivity

• adjustableYes

Page 1633 Mar 2008 Siemens ITS

• lower limit0

• upper limit255

• presetNo retentivity

•Time range

• lower limit10 ms

• upper limit9 990 s

IEC timer•present Yes•Type SFB•Number Unlimited (limited only by RAM capacity)Data areas and their retentivityretentive data area, total All, 128 KB max.Flag•Number, max. 2 048 byte•Retentivity available Yes; MB 0 to MB 2047•Retentivity preset MB 0 to MB 15•Number of clock memories 8; 1 memory byteData blocks•Retentivity adjustable Yes; via non-retain property on DB

Page 1634 Mar 2008 Siemens ITS

•Retentivity preset YesLocal data•per priority class, max. 32 768 byte; Max. 2048 bytes per blockAddress areaI/O address area•Inputs 2 048 byte•Outputs 2 048 byte•of which, distributed

• Inputs2 048 byte

• Outputs2 048 byte

Process image•Inputs, adjustable 2 048 byte•Outputs, adjustable 2 048 byte•Inputs, default 128 byte•Outputs, default 128 byteSubprocess images•Number of subprocess images, max. 1; With PROFINET IO, the length of the

user data is limited to 1600 bytesDigital channels•Inputs 16 384•Outputs 16 384•Inputs, of which central 1 024

Page 1635 Mar 2008 Siemens ITS

•Outputs, of which central 1 024Analog channels•Inputs 1 024•Outputs 1 024•Inputs, of which central 256•Outputs, of which central 256Hardware configurationRacks, max. 4Modules per rack, max. 8Expansion devices, max. 3Number of DP masters•integrated 1•via CP 4Number of operable FMs and CPs(recommended)•FM 8•CP, point-to-point 8•CP, LAN 10Time of dayClock•Hardware clock (real-time clock) Yes•battery-backed and synchronizable Yes•Deviation per day, max. 10 s; Typ.: 2 s•Backup time 6 wk; At 40 °C ambient temperature

Page 1636 Mar 2008 Siemens ITS

•Behavior of the clock following POWER-ON

Clock continues running after POWER OFF

•Behavior of the clock following expiry ofbackup period

Clock continues to run with the time atwhich the power failure occurred

Operating hours counter•Number 1•Number/Number range 0•Range of values 0 to 2^31 hours (when using SFC 101)•Granularity 1 hour•retentive Yes; Must be restarted at each restartClock synchronization•supported Yes•to MPI, master Yes•to MPI, slave Yes•to DP, master Yes; With DP slave only slave clock•to DP, slave Yes•in AS, master Yes•in AS, slave Yes•on Ethernet via NTP Yes; as client1st interfaceType of interface Integrated RS 485 interfacePhysics RS 485Isolated Yes

Page 1637 Mar 2008 Siemens ITS

Power supply to interface (15 to 30 VDC), max.

200 mA

Functionality•MPI Yes•DP master Yes•DP slave Yes•Point-to-point connection NoMPI•Services

• PG/OP communicationYes

• RoutingYes

• Global data communicationYes

• S7 basic communicationYes

• S7 communicationYes

• S7 communication, as clientNo; but via CP and loadable FB

• S7 communication, as serverYes

•Transmission rate, max. 12 Mbit/s

Page 1638 Mar 2008 Siemens ITS

DP master•Services

• PG/OP communicationYes

• Global data communicationNo

• S7 basic communicationYes; I blocks only

• S7 communicationYes

• S7 communication, as clientNo

• S7 communication, as serverYes

• Equidistance mode supportYes

• Isochronous modeYes; OB 61; isochronous mode can only beused alternatively on PROFIBUS DP orPROFINET IO

• SYNC/FREEZEYes

• Activation/deactivation of DP slavesYes

Page 1639 Mar 2008 Siemens ITS

• Number of DP slaves that can besimultaneously activated/deactivated,max.

8

• Direct data exchange (slave-to-slavecommunication)

Yes; As subscriber

• DPV1Yes

•Transmission rate, max. 12 Mbit/s•Number of DP slaves, max. 124•Address area

• Inputs, max.2 Kibyte

• Outputs, max.2 Kibyte

•User data per DP slave

• Inputs, max.244 byte

• Outputs, max.244 byte

DP slave•Services

Yes

Page 1640 Mar 2008 Siemens ITS

• PG/OP communication

• Global data communicationNo

• S7 basic communicationNo

• S7 communicationYes

• S7 communication, as clientNo

• S7 communication, as serverYes; Connection configured on one sideonly

• Direct data exchange (slave-to-slavecommunication)

Yes

• DPV1No

•Transmission rate, max. 12 Mbit/s•Automatic baud rate search Yes; only with passive interface•Transfer memory

• Inputs244 byte

• Outputs244 byte

•Address area, max. 32

Page 1641 Mar 2008 Siemens ITS

•User data per address area, max. 32 byte2nd interfaceType of interface PROFINETPhysics Ethernet RJ45Isolated YesIntegrated switch YesNumber of ports 2Automatic detection of transmission speed Yes; 10/100 Mbit/sAutonegotiation YesAutocrossing YesMedia redundancy•supported Yes•Switchover time on line break, typically 200 ms; PROFINET MRP•Number of stations in the ring, max. 50Change of IP address at runtime, supported YesFunctionality•MPI No•DP master No•DP slave No•PROFINET IO Controller Yes; Also simultaneously with IO-Device

functionality•PROFINET IO Device Yes; Also simultaneously with IO Controller

functionality•PROFINET CBA Yes

Page 1642 Mar 2008 Siemens ITS

PROFINET IO Controller•Services

• PG/OP communicationYes

• S7 communicationYes; With loadable FBs, max. configurableconnections: 14, max. number of instances:32

• Isochronous modeYes; OB 61; isochronous mode can only beused alternatively on PROFIBUS DP orPROFINET IO

• Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP

•Transmission rate, max. 100 Mbit/s•Number of connectable IO devices, max. 128•Max. number of connectable IO devicesfor RT

128

• of which in line, max.128

•Number of IO devices with IRT and theoption "high flexibility"

128

• of which in line, max.61

•Number of IO Devices with IRT and theoption "high performance", max.

64

Page 1643 Mar 2008 Siemens ITS

• of which in line, max.64

•IRT, supported Yes•Shared device, supported Yes•Prioritized startup supported Yes

• Number of IO Devices, max.32

•Activation/deactivation of IO Devices Yes

• Number of IO Devices that can besimultaneously activated/deactivated,max.

8

•IO Devices changing during operation(partner ports), supported

Yes

• Max. number of IO devices per tool8

•Device replacement without swap medium Yes•Send cycles 250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in

the case of IRT with "high flexibility"option)

•Updating time 250 µs to 512 ms (depending on theoperating mode, see Manual "S7-300 CPU31xC and CPU 31x, Technical Data" formore details)

Page 1644 Mar 2008 Siemens ITS

•Address area

• Inputs, max.2 Kibyte

• Outputs, max.2 Kibyte

•User data per address area, max.

• User data consistency, max.1 024 byte

PROFINET IO Device•Services

• PG/OP communicationYes

• S7 communicationYes; With loadable FBs, max. configurableconnections: 14, max. number of instances:32

• Isochronous modeNo

• Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP

• IRT, supportedYes

• PROFIenergy, supportedYes; With SFB 73 / 74 prepared forloadable PROFIenergy standard FB for I-Device

Page 1645 Mar 2008 Siemens ITS

• Shared device, supportedYes

• Number of IO controllers withshared device, max.

2

•Transfer memory

• Inputs, max.1 440 byte; Per IO Controller with shareddevice

• Outputs, max.1 440 byte; Per IO Controller with shareddevice

•Submodules

• Number, max.64

• User data per submodule, max.1 024 byte

Open IE communication•Open IE communication, supported Yes•Number of connections, max. 8•Local port numbers used at the system end0, 20, 21, 25, 80, 102, 135, 161, 8080,

34962, 34963, 34964, 65532, 65533, 65534,65535

•Keep-alive function, supported YesCommunication functionsPG/OP communication Yes

Page 1646 Mar 2008 Siemens ITS

Data record routing YesGlobal data communication•supported Yes•Number of GD loops, max. 8•Number of GD packets, max. 8•Number of GD packets, transmitter, max. 8•Number of GD packets, receiver, max. 8•Size of GD packets, max. 22 byte•Size of GD packet (of which consistent),max.

22 byte

S7 basic communication•supported Yes•User data per job, max. 76 byte•User data per job (of which consistent),max.

76 byte; 76 bytes (with X_SEND orX_RCV); 64 bytes (with X_PUT orX_GET as server)

S7 communication•supported Yes•as server Yes•as client Yes; via integrated PROFINET interface and

loadable FB or via CP and loadable FB•User data per job, max. See online help of STEP 7 (shared

parameters of the SFBs/FBs and of theSFCs/FCs of S7 Communication)

Page 1647 Mar 2008 Siemens ITS

S5-compatible communication•supported Yes; via CP and loadable FCOpen IE communication•TCP/IP Yes; via integrated PROFINET interface and

loadable FBs

• Number of connections, max.8

• Data length for connection type01H, max.

1 460 byte

• Data length for connection type11H, max.

32 768 byte

• Several passive connections per port,supported

Yes

•ISO-on-TCP (RFC1006) Yes; via integrated PROFINET interface andloadable FBs

• Number of connections, max.8

• Data length, max.32 768 byte

•UDP Yes; via integrated PROFINET interface andloadable FBs

Page 1648 Mar 2008 Siemens ITS

• Number of connections, max.8

• Data length, max.1 472 byte

Web server•supported Yes; only read function•Number of HTTP clients 5•User-defined websites YesPROFINET CBA (at set setpointcommunication load)•Setpoint for the CPU communication load 50 %•Number of remote interconnection partners 32•Number of functions, master/slave 30•Total of all Master/Slave connections 1 000•Data length of all incoming connectionsmaster/slave, max.

4 000 byte

•Data length of all outgoing connectionsmaster/slave, max.

4 000 byte

•Number of device-internal and PROFIBUSinterconnections

500

•Data length of device-internal undPROFIBUS interconnections, max.

4 000 byte

•Data length per connection, max. 1 400 byte•Remote interconnections with acyclic

Page 1649 Mar 2008 Siemens ITS

transmission

• Sampling frequency: Sampling time,min.

500 ms

• Number of incominginterconnections

100

• Number of outgoing interconnections100

• Data length of all incominginterconnections, max.

2 000 byte

• Data length of all outgoinginterconnections, max.

2 000 byte

• Data length per connection, max.1 400 byte

•Remote interconnections with cyclictransmission

• Transmission frequency:Transmission interval, min.

10 ms

• Number of incoming200

Page 1650 Mar 2008 Siemens ITS

interconnections

• Number of outgoinginterconnections

200

• Data length of all incominginterconnections, max.

2 000 byte

• Data length of all outgoinginterconnections, max.

2 000 byte

• Data length per connection, max.450 byte

•HMI variables via PROFINET (acyclic)

• Number of stations that can log onfor HMI variables (PN OPC/iMap)

3; 2x PN OPC/1x iMap

• HMI variable updating500 ms

• Number of HMI variables200

• Data length of all HMI variables,max.

2 000 byte

•PROFIBUS proxy functionality

Page 1651 Mar 2008 Siemens ITS

• supportedYes

• Number of linked PROFIBUSdevices

16

• Data length per connection, max.240 byte; Slave-dependent

Number of connections•Max. total number of instances 32•usable for routing X1 as MPI: max. 10; X1 as DP master:

max. 24; X1 as DP slave (active): max. 14;X2 as PROFINET: 24 max.

S7 message functionsNumber of login stations for messagefunctions, max.

16; Depending on the configured connectionsfor PG/OP and S7 basic communication

Process diagnostic messages Yessimultaneously active Alarm-S blocks, max. 300Test commissioning functionsStatus/control•Status/control variable Yes•Variables Inputs, outputs, memory bits, DB, times,

counters•Number of variables, max. 30•of which status variables, max. 30

Page 1652 Mar 2008 Siemens ITS

•of which control variables, max. 14Forcing•Forcing Yes•Force, variables Inputs, outputs•Number of variables, max. 10Status block Yes; Up to 2 simultaneouslySingle step YesNumber of breakpoints 4Diagnostic buffer•present Yes•Number of entries, max. 500

• adjustableNo

• Of which powerfail-proof100

•Number of entries readable in RUN, max. 499

• adjustableYes

• preset10

Isochronous modeIsochronous mode Yes; Via PROFIBUS DP or PROFINET

interfaceAmbient conditions

Page 1653 Mar 2008 Siemens ITS

Operating temperature•Min. 0 °C•max. 60 °CConfigurationprogramming•Programming language

• LADYes

• FBDYes

• STLYes

• SCLYes

• CFCYes

• GRAPHYes

• HiGraph®Yes

•Command set see instruction list•Nesting levels 8Know-how protection•User program protection/password Yes