Date: 23.03.2009 Tender Document No. 81181/G/09/0005 e-tender no : 8000000869 Sn Description Volume Tender Page No. Clause/Para /Section Remarks 1 INSTRUCTION TO BIDDERS (ITB) Vol. I of II Page no. 000019 Clause number 9.4.1 Modification Clause is modified hereunder. 9.4.1. Part-III shall contain Hard copy of Un-priced e-bid, original Bid Security, Power of Attorney, letter of Authority in sealed envelopes and shall be submitted to Project Manager, Suez - Tractebel S.A, New Delhi in physical form by bid due date & time as defined in bid document. 2 INSTRUCTION TO BIDDERS (ITB) Vol. I of II Page no. 000019 Clause number 9.4.2 Modification Clause is modified hereunder. The bidder has an option to submit all above documents except Hard copy of Un-priced e- bid and letter of Authority in physical form within 7 (seven) days reckoned from bid due date provided scanned copies of the above documents have been submitted as a part of e - bid on or before the bid due date and time. 3 ADDENDUM TO ITB FOR e-TENDERING Vol. I of II Page no. 000043 Clause number 1.8 Addition Please add "Hard copy of Un-priced e-bid" before bid document fee in 1st line of para 2. 4 MATERIAL REQUISITION Vol. II of II Page no. 000005 Note Addition USM & FC is preferred to be of same make. If it is of different make, Metering vender shall be responsible to integrate the same in his system for proper monitoring & control. 5 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000035 Cl. No. 1.11 Deletion Addition 100 Mtr. Tentative distance between Field JB & Control Room Dahej Dispatch Station - 225 Mtr. 6 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000035 Cl. No. 1.11 Addition Following para added. "Existing Gas Chromatograph at Dahej Dispatch Station is of Daniel make Danalyzer 570 with 2350 controller. However bidder to verify the same ." 7 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000065 Appendix 5 Point No. 29 Addition Read it as Accuracy +/- 0.3% or better inclusive of lab uncertainty 8 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000048 Cl. No.12 Addition Following para added. Flow computer shall be certified for Natural Gas custody transfer application from NMI/PTB/NPL/ Equivalent type certification for natural gas custody transfer is required. 9 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000048 Cl. No.12 Addition Following para added. Vender shall supply validation software for flow computer, SOS calculation software, Software for online verification & diagnostic of USM as per AGA 9, Flow configuration software, any other software as required licensed in the name of GAIL 10 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000049 Cl. No.14.3 Addition Following para added. The custody transfer instruments, Transmitter shall be installed with in the environment enclosure to reduce the effect of ambient temperature variations. 11 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000046 Cl. No.10 4.3 Addition / Modification Power Supply Type - Hot Swappable redundant Out Put - 24 VDC , 20Amp 12 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000067&69 Appendix 5 Pressure Transmitter Point No. 10 Temperature Transmitter Point No. 10 Modification Pressure transmitter Accuracy - 0.04 % of span including the combined effect of repeatability, linearity, hysteresis etc. Temperature transmitter Accuracy - 0.2 % of FSD. 13 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000069 Appendix 5 Addition Following Note added. Note 2 -Temp transmitter shall have dual compartment housing 14 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000048 Cl. No.12 Addition Following para added. "Flow computer shall have facility for manual entry (Password protected ) of Atmospheric pressure as per site condition. Also heating value shall be calculated as per GPA 2172/2145" Amendment/Addition/Modification/Deletion CORRIGENDUM # 1 SUPPLY OF METERING SYSTEM (USM BASED) FOR DAHEJ VIJAIPUR PIPELINE UP-GRADATION PROJECT (DVPL-II) Commercial- Volume I of II Technical- Volume II of II --- Page 1 of 3

CORRIGENDUM # 1 Date: 23.03.2009 SUPPLY OF … · Date: 23.03.2009 Tender Document No. 81181/G/09/0005 e-tender no : 8000000869 Sn Description Volume ... Also heating value shall

  • Upload
    buibao

  • View
    212

  • Download
    0

Embed Size (px)

Citation preview

Date: 23.03.2009Tender Document No. 81181/G/09/0005e-tender no : 8000000869

Sn Description Volume Tender Page No.

Clause/Para/Section Remarks

1 INSTRUCTION TO BIDDERS (ITB) Vol. I of II Page no. 000019 Clause number 9.4.1 Modification

Clause is modified hereunder.

9.4.1. Part-III shall contain Hard copy of Un-priced e-bid, original Bid Security, Power of Attorney, letter of Authority in sealed envelopes and shall be submitted to Project Manager, Suez - Tractebel S.A, New Delhi in physical form by bid due date & time as defined in bid document.

2 INSTRUCTION TO BIDDERS (ITB) Vol. I of II Page no. 000019 Clause number 9.4.2 Modification

Clause is modified hereunder.

The bidder has an option to submit all above documents except Hard copy of Un-priced e-bid and letter of Authority in physical form within 7 (seven) days reckoned from bid due date provided scanned copies of the above documents have been submitted as a part of e - bid on or before the bid due date and time.

3 ADDENDUM TO ITB FOR e-TENDERING Vol. I of II Page no. 000043 Clause number 1.8 Addition

Please add "Hard copy of Un-priced e-bid" before bid document fee in 1st line of para 2.

4 MATERIAL REQUISITION Vol. II of II Page no. 000005 Note AdditionUSM & FC is preferred to be of same make. If it is of different make, Metering vender shall be responsible to integrate the same in his system for proper monitoring & control.

5 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000035 Cl. No. 1.11

Deletion

Addition

100 Mtr.

Tentative distance between Field JB & Control RoomDahej Dispatch Station - 225 Mtr.

6 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000035 Cl. No. 1.11 Addition

Following para added."Existing Gas Chromatograph at Dahej Dispatch Station is of Daniel make Danalyzer 570 with 2350 controller. However bidder to verify the same ."

7 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000065

Appendix 5 Point No. 29 Addition Read it as

Accuracy +/- 0.3% or better inclusive of lab uncertainty

8 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000048 Cl. No.12

Addition Following para added.Flow computer shall be certified for Natural Gas custody transfer application from NMI/PTB/NPL/ Equivalent type certification for natural gas custody transfer is required.

9 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000048 Cl. No.12 Addition

Following para added.Vender shall supply validation software for flow computer, SOS calculation software, Software for online verification & diagnostic of USM as per AGA 9, Flow configuration software, any other software as required licensed in the name of GAIL

10 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000049 Cl. No.14.3 Addition

Following para added.The custody transfer instruments, Transmitter shall be installed with in the environment enclosure to reduce the effect of ambient temperature variations.

11 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000046 Cl. No.10 4.3 Addition /

Modification

Power Supply Type - Hot Swappable redundant

Out Put - 24 VDC , 20Amp

12 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II

Page no. 000067&69

Appendix 5 Pressure Transmitter

Point No. 10

Temperature TransmitterPoint No. 10

Modification

Pressure transmitter Accuracy - 0.04 % of span including the combined effect of repeatability, linearity, hysteresis etc.

Temperature transmitter Accuracy - 0.2 % of FSD.

13 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000069

Appendix 5 AdditionFollowing Note added.Note 2 -Temp transmitter shall have dual compartment housing

14 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000048 Cl. No.12 Addition

Following para added."Flow computer shall have facility for manual entry (Password protected ) of Atmospheric pressure as per site condition. Also heating value shall be calculated as per GPA 2172/2145"

Amendment/Addition/Modification/Deletion

CORRIGENDUM # 1SUPPLY OF METERING SYSTEM (USM BASED)

FORDAHEJ VIJAIPUR PIPELINE UP-GRADATION PROJECT (DVPL-II)

Commercial- Volume I of II

Technical- Volume II of II

---

Page 1 of 3

Date: 23.03.2009Tender Document No. 81181/G/09/0005e-tender no : 8000000869

Sn Description Volume Tender Page No.

Clause/Para/Section RemarksAmendment/Addition/Modification/Deletion

CORRIGENDUM # 1SUPPLY OF METERING SYSTEM (USM BASED)

FORDAHEJ VIJAIPUR PIPELINE UP-GRADATION PROJECT (DVPL-II)

15PIPING & INSTRUMENTATION DIAGRAM

Vol. II of II Page no. 0000162 Note- 4 AdditionFollowing Note added. Note- 4 - PT Tapping shall be taken from USM body and valve size shall be 1/2''.1st isolation valve of PT shall be welded type and 2 end one shall be flanged type

16 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000042 Cl. No.6.1 Addition Flow Meter shall be Multi path (Min. Four Path)

17 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000043

Cl. No.6.1 Point No. 8 Deletion No. of path to be decided by vender to meet the accuracy and repeatability requirement as

specified

18 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000065

Appendix 5 Data Sheet USM

Note- 2Deletion

No. of path to be decided by vender to meet the accuracy and repeatability requirement as specified

19 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000066

Appendix 5 Data Sheet Flow

ComputerPoint- 8

Modification

Read it as

(Isolated 4 to 20 mA signal for Corrected flow rate, Uncorrected flow rate, Line Pressure, Line Temperature, Energy rate.)

20 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000085 Item No. 3(a) & 3(b) Modification 3(a) Trasucer pair for 16'' size USM - Qty. 1 Set

3(b) All electronics cards for 16'' Size USM - Qty. 1 Set

21 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000053

Cl. No.16.1.1 Para Two

Addition / Modification

Calibration point covering the following nominal flow rates are to be used as a minimum during wet calibration : 0.025Qmax,. 0.05Qmax, 0.1Qmax, 0.25Qmax, 0.50Qmax,0.75Qmax and qmax. and error curve shall be obtained. Flow verification for at least two Points shall be done after adjustment / incorporation of factors obtained through calibration and the same to be recorded in the calibration report, as per AGA-9

22 DATA SHEET BALL VALVE Vol. II of II Page no. 0000149 Addition Ball valve data sheet no. VBA-6C1 attached.

23 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 0000163

Piping General Arrangement Drawing Dahej Dispatch Station

ModificationRevised GAD No. 81181-L-16-0102 rev 3 attached.

24 MATERIAL REQUISITION Vol. II of II Page no. 0000005 S. N. A4

Deletion PortRead it as Supply of Communication Card In existing Gas Chromatograph of same make & model and Interfacing and configuration with FC includine necessary cable & cabling

25 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000065

Appendix 5 Data Sheet USM

Sr. No.- 32

Addition / Modification

Housing Material : SS316 / Aluminium should be weather proof to IP65

26 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000066

Appendix 5 Data Sheet Flow

ComputerPoint-11

Addition / Modification

Energy : kacl / BTU shall be user selectable

27 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000066

Appendix 5 Data Sheet Flow

Computer Addition

Following Note added.Note 14 - Internal or external USB converter shall be provided with each flow computer for connecting it to USB port of laptop for configuration

28 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000066

Appendix 5 Data Sheet Flow

Computer Addition

Following Note added.Note 15- Vender shall provide the necessary hardware / software (Licensed in favor of GAIL) for configuration , Audit trail and historical retrieval of flow computers. Vender shall provide complete details / software's for SCADA Communication.

PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000066

Appendix 5 Data Sheet Flow

ComputerNote- 10

Modification

Read it as

Audit trail & event log feature should be there. Audit Trail feature should display detailed description, old and new value of parameter changed along with time stamp.

29 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000048 Cl. No.12

AdditionFollowing para added.Speed of sound comparison should be done in the stream flow computer for the speed of sound measured value from the USM and the speed of sound calculation based on the GC component data as per AGA 10. If the difference between the actual SOS and the calculated one is more than the permissible limit then the flow computer shall generate a alarm

30 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000043

Cl. No.6.1 Addition

Following added.

Alarm should appear when USM Signal streangth is less than predifined limit

31 PTS-INSTRUMENTATION FOR PACKAGE UNIT Vol. II of II Page no. 000066

Appendix 5 Data Sheet Flow

ComputerS.No. 18

Modification

Please read the S.No. 18 of data sheet as "Elaborate & Sufficient on- line diagnostic to ascertain acurate & proper functioning of flow computer and there shall also be online display of USM dignostic parameter".

32 MATERIAL REQUISITION Vol. II of II Page no. 000005 S. N. A6 AdditionHand held communicator is added in MR S.no. A 6.

---

Page 2 of 3

Date: 23.03.2009Tender Document No. 81181/G/09/0005e-tender no : 8000000869

Sn Description Volume Tender Page No.

Clause/Para/Section RemarksAmendment/Addition/Modification/Deletion

CORRIGENDUM # 1SUPPLY OF METERING SYSTEM (USM BASED)

FORDAHEJ VIJAIPUR PIPELINE UP-GRADATION PROJECT (DVPL-II)

For and on Behalf of GAIL (India) Limited

Daniel MertensProject Manager (DVPL-II)

Suez-Tractebel SA,10-A, Shivaji Marg, new Delhi- 110015

Tel:- + 91 11 4701 2209/2200Fax. + 91 11 4701 2244

e-mail: [email protected]

---

Page 3 of 3

I. PROCESS DATA - PIPE CLASS : 6C1

- FLUID : Natural Gas Fluid Symbol : NG

- OPERATING CONDITIONS : NGPressure (barg) :Temperature (°C) :

- DESIGN CONDITIONS : NGPressure (barg) :Temperature (°C) :

II. VALVE DATA - CONSTRUCTION DESIGN : API 6D and ASME B 16.34- TYPE :

- PUPS :::

:

- END CONNECTION :

- RATING : 600#- :- :

- :

- SEAT & SEAL : A 350 LF2 & PTFE - FIRE SAFE : Yes- ANTI-BLOW OUT : Yes- ANTISTATIC : Yes- EXTENSION STEM : No- OPERATOR : Wrench Operated - PAINTING

Surface preparation : SA 2.5Primer : 30 - 40 µmFinish : 30 - 40 µm

- INSULATION : NoNOTE 1 :

BODY MATERIAL

ASTM A350-LF2 BALL MATERIAL

BW/Flanged as per P & I diagram 81181-P-01-0136 (All butt welded ball valves shall have fully welded body and flanged ball valve can be fully welded/split body)

REMARKCHK17.03.09

STEM

REV0 PKN PK

BY APP

Ball and stem to be electroless nickel plated (ENP), min thichness 25 µ, to reach a suitable hardness or equivalent proven design

FULL BORE - TRUNION MOUNTED - DOUBLE BLOCK AND BLEED

NC

LENGTH

THICKNESS SCH 80

First IssueDATE

Refer Painting System & Colour Code for Final Layer (81181/M/98/0156)

DATA SHEET N°DAHEJ VIJAIPUR

MANUAL BALL VALVES (SIZES UP TO 2")ABOVEGROUND SERVICE

DATA SHEETPIPELINE UPGRADATION PROJECT

(DVPL II) 81181VBA-6C1

Min. 15/Max.90.25Min. 0/ Max. 65

MATERIAL

Page 1 of 2

97.98

YES

ASTM A350-LF2

ASTM A 333 GR 6

- 20 to 65

2 x ND or 300 mm (Min.)

ASTM A350 LF2

III. TEST - HYDROSTATIC SHELL TEST

Test pressure : 1.5 x Design PressureTest medium : Water

- HYDROSTATIC SEAT TEST Test pressure : 1.1 x Design PressureTest medium : Water

- AIR SEAT TEST Test pressure : 6 barTest medium : Air

- FUNCTIONAL TEST : 3 Opening / ClosingTest pressure : ATM & Maximum differential pressure

- LEAK TEST : Yes- DOUBLE BLOCK & BLEED TEST : Yes- TORQUE TEST : Yes- ANTISTATIC TEST : Yes- FIRE TEST : Yes- Yes

IV. QUALITY CONTROL *- MATERIAL CERTIFICATES :- ALL TESTING CERTIFICATES : TEST, FIRE SAFE, PAINTING, ANTISTATIC…

* Note: Vendor shall submit detail QAP for approval of Owner/Owner's representative. All major tests (except fire test) as indicated above will be witnessed by TPIA.

17.03.09BY

PKN PK

DATA SHEETMANUAL BALL VALVES (SIZES UP TO 2")

ABOVEGROUND SERVICE

NOTE : UNLESS OTHERWISE STATED, ALL TESTS WILL BE WITNESSED BY THE PURCHASERVISUAL AND DIMENSIONAL EXAMINATION TEST:

DATA SHEET Page 2 of 2

PIPELINE UPGRADATION PROJECT

VBA-6C1

DATA SHEET N°

REV0

DAHEJ VIJAIPUR

EN 10204 - 3.2

(DVPL II) 81181

NCCHK

First IssueREMARKAPPDATE

Sr. No. Clause no. Description Bidder’s Query/Clarification TE Reply

VOL I OF II (COMMERCIAL)1 Clause no. 5.1.2. Page

no.000007 of IFB Kindly clarify what is similar type /model. Does similar type means "Size and rating of the earlier supplied meters should be same or higher size as the proposed meter". Or is it acceptable if the earlier supplied meter should be the same make and model? Or can we furnish separate orders (PTR), one for the meter and another for the Flow computer.

Tender Conditions Prevails. Clause no. 5.1.2 on pg. 000007 of IFB, Vol. I of II is explicitly clear.

2 Whether Indian bidder can quote in Indian Rupees based on Global PTR available for Ultrasonic metering system

Tender Conditions Prevails.Clause no. 11 of ITB on page no. 000022 is explictly clear in this regard.

3 Whether Indian bidder can quote in Foreign currency based on Global PTR available for Ultrasonic metering system

Tender Conditions Prevails.Clause no. 11 of ITB on page no. 000022 is explictly clear in this regard.

4 Clause no. 11 of GCC Customer should indemnify GE if customer causes any breach of third party IPR by making useof GE products in any unauthorized manner

Tender Conditions Prevails.

5 Clause no. 12 of GCC There should be a cure period of 30 days before the guarantee amount is claimed from the Bank

Tender Conditions Prevails.

6 Clause no. 15 of GCC We request you to please confirm the time period for drawing & datasheet approval for achieving the required delivery period

Tender Conditions Prevails. Purchaser / Consultant will provide approval / comments on drawings / documents within 15 days from the date of receipt of drawings / documents.

7 Clause no. 20.1, para 4 of GCC

Replaced or repaired goods to have a warranty of 12 months from date of first repair or replacement

Tender Conditions Prevails.

8 Clause no. 30 of GCC Please confirm which are the matters where the decisions of the Engineer –in Charge are deemed to be final.At least of two of three independent arbitrators selected by GAIL should be retired high court judges

Tender Conditions Prevails.

9 Clause no. 36.3 of GCC Recovery should not be made against sums due under other contracts Tender Conditions Prevails.

10 Clause no. 28.3 of GCC. Page no.000073

Termination for Convenience will not apply Tender Conditions Prevails.

11 Clause no. 5 Bid Evaluation Criteria. Sub Clause no. 5.1.1 Technical, Page 000007 of IFB (page 05 of 09)

GE Sensing - India being the Indian subsidiary of GE Sensing, Ireland(Original Manufacturer of Ultrasonic custody flow meter), whether GE Sensing- India can submit the bid in its letter head on account of our corporate policy. In this case GE Sensing India will only submit the bid documents to GAIL through e- tender, however all BEC back up documentation pertaining to Original Manufacturer, Order placements & execution of the project will be by GE Sensing, Ireland (the original manufacturer).Tender will be submitted /uploaded through E- tender using GE Sensing -India vendor code with its digital signature. Requesting GAIL/Tractebel to accept this. We wish to mention herewith that GE sensing India works in this fashion with all PSU's including EIL/IOCL and even GAIL plants.

Tender Conditions prevails. Bidder should meet the Bid Evaluation Criteria.

12 Clause no. 5 Bid Evaluation Criteria. Sub-clause no. 5.1.2 Technical, Page 000007 of IFB (page 05 of 09)

We understand that bidder or proposer of ultrasonic flow meter shall have supplied Ultrasonic meter & flow computer ( any make/model) for similar gas metering application.Also " similar type /model" as mentioned in the tender shall be applicable to Ultrasonic Flow meter only and not for the flow computer, because all Ultrasonic flow meter manufactures are not manufacturing flow computers. In this case we understand that Ultrasonic meter shall be of 16"/600# supplied for similar application & the same should have been hooked up with any make/model of flow computer certified for Natural Gas custody metering. Kindly confirm. Further to this we would also like to mention that GE Sensing Ireland may not have supplied theFlow computer along with the qualified model of flow meter as applicable to this tender, however our UFM has been integrated with the customer's flow computer and we have the letterfrom the customer that GE Sensing UFM is working with flow computer with satisfactory performance. Please confirm formally if this is acceptable to BEC criteria.It shall also not be out of context to mention herewith that the intend behind this is to establish the capability of the supplier both technically and commercially and not to bind him to be a manufacturer and supplier of all items under the requirement

Refer reply given above at S.No. 1

Elster-Instromet India Query13 Page 21 Vol I of II, point

10.8.3 (ITB) & Page 130

Pt. 6.1.1 Consignees address for Indian Bidder

Please confirm, transportation from the Vadhodia Store to Dahej Site is not in our scope of supply.

Bidder understanding is correct.

14 Page 71, Vol I of II, point 26.1.1 (GCC).

The Total Contract Price is inclusive all applicable taxes & duties alongwith the per diem charges for X nos. of days for the Supervision of Installation & Commissioning Assistance of the supplied materials.In view of the same may we request GAIL/Tractebel to consider the Price Reduction Schedule on ex-works price and not on the contract price?

The Taxes and Duties are charged at actuals as applicable during the time of supply.

The Charges for Supervision of Installation & Commissioning assistance is a completely separate entity / works which has no connection with the event of any delay in the supply and is paid on actual no. of mandays and not on the X no. of days indicated in SOR; as per the IFB / RFQ - the X no. of days indicated in SOR is only considered for the evaluation purpose.

Tender Conditions prevails.

For taxes & duties, refer clause no. 10.8.7.3 on page no. 000021 of Volume I of II which is explicitly clear.

The Supervision of Erection ,Testing & Commissioning is payable on per diem rate at actuals. Refer Note no. 2 of SOR for Supervision Charges

15 General In case of discrepancy between the e-bid and the hard copy of the bid, the e-bid shall prevail. Kindly confirm our understanding?

Bidder understanding is correct. Refer para 5 " Part-I (Un-Priced Bid) on page no. 000009 of Volume I of II.

16 Volume I of IISOR for Indian Bidders &Page no. 31-32, pt. no. 30.1.2

Please note that as the Taxes are to be added on the Prices indicated at Column (2), the same should be Unit / Total Ex-works inclduing P& F but excluding Excise Duty & CST /VAT.The same is applicable for pt. no. 30.1.2 on page no. 31 & 32 under the Evaluation of Bids for pt. A (i) and C(i).

Tender Conditions Prevails. FOT despatch point means , all inclusive price at bidder's works excluding Taxes & Duties.

REPLY TO PRE BID QUERIES – 1SUPPLY OF METERING SYSTEM FOR DVPL-II

DATE : 23/03/09Tender doc. no. :81181/G/09/0005e-tender no. : 8000000869Owner : GAIL

Page 1 of 6

Sr. No. Clause no. Description Bidder’s Query/Clarification TE Reply

REPLY TO PRE BID QUERIES – 1SUPPLY OF METERING SYSTEM FOR DVPL-II

DATE : 23/03/09Tender doc. no. :81181/G/09/0005e-tender no. : 8000000869Owner : GAIL

17 Page 130, Vol I of II, point 6 (Payment Terms & Mode of Payment).

Please confirm that the invoice has to be raised in the name of GAIL - NOIDA. Bidder understanding is correct. Refer clause no. 6 on page no. 000130 of Volume I of II of tender document..

18 Clause no.5. Bid Evaluation Criteria Vol. I of II, Sub Clause no.5.1.2

Please confirm that the invoice has to be raised in the name of GAIL - NOIDA. Refer reply given above at S.No. 17

VOL II OF II (TECHNICAL)As per GAD No.81181-L-16-0102 R2 & P&ID No.81181-P-01-0136 R2,Dimension for the upstream & Downstream spools is not clear.GAD indicates the complete distance (11434 mm) between the isolation ball valves whilst the P&ID indicates an upstream spool (no length mentioned) before the Flow Conditioner + Flow Conditioner + 10D Upstream Spool + Meter + 5D Downstream Spool only.Further the tapings shown on the second Downstream Pipespool as well as the second Downstream Pipespool on the GAD is not indicated in the Package scope on the P&ID.Request you to kindly confirm / clarify the exact scope - preferably by providing a separate GAD / P&ID for the Bidders scope ?

Battery limits are clearly defined in P & ID.

Refer Corrigendum # 1 S.No. 23. Revised GAD in in enlargd form is enclosed.

Please confirm that the size of 16" is final and we do not have to size the meter for the required flow capacity, Else please provide the velocity limit at which the meter has to be sized ?

Meter size is 16''.

20 Page 5,Vol II of II, Item No.: 3

Flow Computer alongwith Printers It is understood that a common printer between the two Flow Computers with a change over switch is acceptable?

One No. portable laser printer required for each Flow Computer

Kindly confirm Model of existing Gas Chromatograph? Please refer Corrigendum # 1 , S.N. 6Requirement of communication port / cards is of 2 nos.Kindly confirm that 2 additional communications ports are required to be supplied by the bidder for the existing Gas Chromatograph?

It is clarified that an independent communication port from existing GC to each new flow computer is required.

Kindly confirm distance between the Gas Chromatograph Control Unit and the Control Panel to be supplied by the bidder for the interconnecting cables?

Both are in same room so distance will be 20 m Max

22 Page 17,18, PTS, Special Instructions to ContractorsVol II of II, Item No.: 3

Interfacing with Other ContractorsMinimum soft signals from Flow Computer to RTU, Metering Vendor to also provide additional information which is necessary to monitor.

17 parameters have been defined in this list wherein the type of Signal indicated is Analog.It is understood that the same is a typographical mistake and all this signals have to be soft, i.e. Modbus. - Please confirm our understanding.

All these signals are soft signal and is to be communicated over Modbus.

23 Page 30, Appendix - I,Vol II of II, Item No.: 7.5

Flow Metering Measurement Computer SystemMakeModelDescription

It is understood that only the Flow Computers are to be supplied and no separate Metering Supervisory system is envisaged in the bidders scope of supply.Please confirm our understanding.

The flow computer shall be installed in a pre-wired control panel having hot swappable redundant power supply and other accessories.

24 Page 52, PTS Instrumentation for Package Unit,Vol II of II, Sr. No.: 16.1.

Ultrasonic flow meter including straight run pipe and flow straightner, third party "wet;-calibrations (bi-directional flow for bi-directional meters and uni-directional calibration for uni-direction meters) should be done in flow labs as detailed below: * Trans Canada Calibrations, (TCC) Canada ,* NMI, Westerbork, Netherlands* Pigsar - Dorsten -Germany* Colorado Engineering Experiment Station Inc.(CEESI) USA.

Is Calibration at the Advantica Flow Lab in Bishop Auckland acceptable.Bishop Auckland facility is Traceable to the harmonized reference value which have been realized between PTB-Pigsar, NMI-Bergum, PTB-Groningen & NMI-Westerbork.Further also confirm that Calibration is allowed at any facility of NMI / PTB which are either part of the Harmonization of the calibration Facilities or Traceable to these Harmonized calibration facilities. Documentary proof can be provided during the later stage.

Bidder may also propose name of new lab for wet calibration work alongwith proper credential in their bid. However same is subject to approval from purchaser / consultant . The decision of purchaser / consultant shall be final & binding on the bidder.

25 Page 53, PTS Instrumentation for Package Unit,Vol II of II, Sr. No.: 16.1.1, Pt. No. 4

The transmitters (PT and TT) has to be calibrated with Flow computers in the same combination of installation, this leads to better system accuracy.

As per our standard engineering practice, we propose to use the pressure and temperature transmitters with digital communication (HART protocol). This means that communication between the flow computers and the pressure and temperature transmitters is fully digital. The flow computer is merely a digital calculator that does not require calibration.Please refer to the attached application note for more details on the benefits of digital HART communication.We propose to supply the pressure and temperature transmitters with OEM / factory calibration certificates. The flow computer need not be calibrated. Kindly confirm acceptance of the PT & TT with factory calibration report.

Tender condition prevails

26 Page 61, APPENDIX 3, SPARE Capacity, item 1Vol II of II

For Multi Core Cables : Spare core of 20% Spare capacity is required.

27 Page 73, APPENDIX 6, Instrument CablesVol II of II

Instrument cables shall be 1P, 2P, 6P & 12P only. No other combinations are acceptable. All cables shall be FRLS to IEC 332 Part 3 Cat A.

28 Page 65, APPENDIX 5, Data Sheet for Ultrasonic Flow Meter Pt. 13.Vol II of II

Transducer material : ASTM A 182 F316

As per the manufacturers standard it is A182 F304. Kindly confirm the same is acceptable?

The transducer material shall be suitable for the given process condition.

Please confirm that for 2P cable where both the pairs are being used the spare capacity is not required. Spare capacity is required.

21 Page 5,Vol II of II, Item No.: 4

Supply of Communication port/cards in existing Gas chromatograph of same make & model and interfacing and configuration with FC.

19

Page 5,Vol II of II, Item No.: 1

16" size Two No.USM Based Gas Meter of capacity 20 MMSCMD each (design) along with meter run (Upstream & Downstream), PT & TT and Flow Profiler which includes all accessories, instruments, instrument isolation valves, fittings, flanges, pipes, tubes, etc.as per P & ID, PTS 81181/J/21/0560 and PTS 81181/J/21/0561.

Page 2 of 6

Sr. No. Clause no. Description Bidder’s Query/Clarification TE Reply

REPLY TO PRE BID QUERIES – 1SUPPLY OF METERING SYSTEM FOR DVPL-II

DATE : 23/03/09Tender doc. no. :81181/G/09/0005e-tender no. : 8000000869Owner : GAIL

29 Page 65, APPENDIX 5, Data Sheet for Ultrasonic Flow Meter Pt. 32Vol II of II

Housing Material : SS316 As per the manufacturers standard it is Aluminum.Kindly confirm, if the same is acceptable?

Refer correigendum sr No.25

30 Page 65, APPENDIX 5, Data Sheet for Ultrasonic Flow MeterVol II of II

Type: Multipath (Note 2)Note 2: No. of Path to be decided by vendor to meet the accuracy and repeatability requirement specified.

As per AGA-9 , the number of path shall be multipath. However, in the event of Loss of one Path in Multipath meter for 2 path meters, what about the Compliance to AGA-9 for Custody Transfer, will GAIL accept non-compliant AGA-9 Meter?We propose that minimum 3-path should be used so that in the event of loss of one-path, the meter yet remains a multipath meter, fulfilling the AGA-9 requirement.

Please refer Corrigendum # 1 , S.N. 16

1) Requirement of 5 nos. of Analog Output (Hardwired) for the listed parameters have been indicated, with an etc. at the end of the list.We request GAIL /Tractebel to kindly confirm the Exact nos. of Analogue Output required to avoid exchange of unnecessary dialogues in future during the project execution stage.

Please refer Corrigendum # 1 , S.N. 19

Further it is understood that all this Analogue outputs have to be individually galvanically isolated. - Please confirm

Bidder's Under standing is correct.

32 Page 67, APPENDIX 5, Data Sheet for Pressure

TransmittersVol II of II

Accuracy for Pressure Transmitters It is proposed to use PT with higher accuracy i.e. 0.04% or better for Metering Pressure Transmitters Please refer Corrigendum # 1 , S.N. 12

33 Page 69, APPENDIX 5, Data Sheet for

Temperature TransmittersVol II of II

Case shall be as per manufacturer's standard

Kindly confirm that the same shall be single chamber of dual chamber? As Technically it is better to use a dual chamber Transmitter in the Hazardous Area. Please refer Corrigendum # 1 , S.N. 13

34 Page 85, List of MandatorySpares,

Item No. 3b), Vol II of IIAll Electronic Cable for 16" Size USM

Please clarify the requirement ? Standard Tractebel RFQ usually include the Electronic Cards to be supplied as Mandatory Spares.

Please refer Corrigendum # 1 , S.N. 20

35

Page 85, List of MandatorySpares,

Item No. 4), Vol II of II

Flow Computera) Digital Input Card, b) Digital Output Cardc) Analog Input Card, d) Serial Carde) Processor Card & f) Internal Battery Module

Please clarify that in the event the Digital input and Analog input are on the same board, than only one card has to be supplied. It is Acceptable.

36 Page 85, List of MandatorySpares,

Item No. 7, Vol II of II

Manifoldsa) 2 way valve manifold (1/2" x 1/2" x 1/2" NPTF)

Kindly confirm that 2 way valve manifold (1/2" x 1/2" x 1/4" NPTF) is acceptable for the mandatory spares as well as the Pressure Transmitters? Approved makes as per the RFQ are Parker & Swagelok and this vendors supply 1/4" drain connection as standard for their manifolds.

Accepted

37 Page 85, List of MandatorySpares,

Item No. 8 b), Vol II of II

Instrument Fittingsb) 1/2" NPT Plug - 2 nos. In the event the above manifold is acceptable, please confirm that the plug shall be of 1/4" size. Accepted

Chemtrols Industries Limited 38 Data Sheet of USM. Line

item 10, Pg 65Wet Calibration with NG is required At what pressure should wet calibration be carried out? USM Meter shall be calibrated at Min. 50 Bar Pressure however It is

depend on Max. avaliable Calibration Pressure of Tender specified agencies.

39 Data Sheet of USM. Line item 11, Pg 65

Multipath meter is required. You have not indicated the no of path. As a regular supplier and as per manufacturer recommendations, we strongly recommend the use of atleast 4 path in the USM. Please refer Corrigendum # 1, S.N. 16

40 Data Sheet of USM. Line item 13, Pg 65

Transducer material should be ASTMA182 F316

We supply transducer with Titanium MOC as a standard. This is even better than the required. Moreover the same model of meters (with Titanium transducers) has been in operation at Gail also satisfactorily.

The transducer material shall be suitable for the given process condition.

41 Data Sheet of USM. Line item 17, Pg 65

Transducer should be retractable type Does the bidder have to quote for a Retractable Tool which is used to retract the transducers under pressurised conditions.

The transducer construction should be retractable type. Retractable tool is not required.

42 Data Sheet of USM. Line item 32, Pg 66

Transmitter housing material to be SS316 MOC

We optionally suggest the use of marine grade Aluminum housing (low copper content) for the transmitter, which we use as a standard. Aluminum is light weight, Corrosion resistant and easier to transport. Moreover it has a extensive PTR worldwide.

Refer correigendum sr No.25

43 Data Sheet of USM. Line item 38, Pg 66

Manual Entry of gas composition is required.

The meters we offer cannot take manual entry of Gas Composition. Ideally Gas composition should be manually entered only in the Flow computer. Since it is custody transfer application, the flow computation is done in the flow computer and hence gas composition should be entered in the flow computer and not flow meter. Flow meter gives only the raw reading.

Bidder's Understanding is correct

44 Data Sheet of USM. Note no 5, Pg 65

Approved makes We request you to include M/s Sick Maihak Germany as an approved vendor for USM. Sick make meters are supplied to Gail in the past and have satisfactory performance.

Please refer Clause no. 5.1.2 on pg. 000007 of IFB, Vol. I of II & Corrigendum # 1, S.N.16.

45 Piping Specification. Page 139

Specs calls for Basic piping material as Low temperature Carbon steel

From the process parameters, we understand that it is not a Low temperature application. Hence piping material can be Simple Carbon steel and not LT versions.

Bidder to follow Tender requirement.

46 PTS - Page 15 of bid, clause 1.10

Fabrication/Manufacturing shop to have U stamp certification.

We request that this requirement should be deleted. Bidder to follow Tender requirement.

47 PTS - Page 16 of bid, Clause 3, Scope

Tender calls for Supply of Communication ports/cards in existing GC of same make and interfacing and configuration with FC.

We suggest that the Communication cards/ports should be directly procured by Gail. As a competitor, we may not get proper support from the vendor of existing make in terms of delivery,price and technical assistance in achieving the same.

Bidder to follow Tender requirement.

48 We understand that we have to supply the USM and runs as a complete Skid mounted unit. Please confirm. If yes, shall we follow the P&ID as on page 162 on tender docs.

Bidder to provide Meter along with Meter Run with flow profiler as per P & ID & MR as loose delivery Item

49 We will be following the P&ID furnished on page 162 of your tender docs and skid shall be supplied as per the same. Please confirm

Bidder to provide Meter along with Meter Run with flow profiler as per P & ID & MR as loose delivery Item

50 Please confirm whether we have to supply a Hand Held Communicator. Hand Held Communicator is in scope of supplyPlease refer Corrigendum # 1 , S.N. 32

51 Please furnish the data sheets of all the valves required as per the P&ID on page 162. Please refer Corrigendum # 1 , S.N. 22

Output: a) Isolated 4-20 mA signal for corrected flow rate, uncorrected flow rate, line pressure, line temperature, energy rate, etc.

Page 66, APPENDIX 5, Data Sheet for Flow Computer Pt. 8Vol II of II

31

Page 3 of 6

Sr. No. Clause no. Description Bidder’s Query/Clarification TE Reply

REPLY TO PRE BID QUERIES – 1SUPPLY OF METERING SYSTEM FOR DVPL-II

DATE : 23/03/09Tender doc. no. :81181/G/09/0005e-tender no. : 8000000869Owner : GAIL

52 Doc. 81181/J/91/0558 - Material Requisition/ A.Dahej point #4000005 (Page 1 of 08 )

Supply of communication ports/cards in Existing Gas Chromatograph ( GC) of same make & model and interfacing and configuration with FC.

Requesting Tractebel - GAIL to provide the details of existing GC & its present condition to adapt additional Com. ports requirement as per tender. Requesting Tractebel - GAIL to provide this additional com ports thru the GC- OEM itself.

Please refer Corrigendum # 1 S.N. 6

53 Doc. 81181/J/21/0559 . Point # 03000017( Page 3 of 05 )

Metering Panel FC to RTU : Type of signal Analog ( for 17 parameters)

Please clarify, the analog o/p requirement for all these parameters. We would recommend the same will be available through the RS 485, Analog signals for 17 parameters as per the table is cumbersome to provide in Flow computer.

As per tender it is clearly mentioned required signals shall be sent toRTU on Modbus

54 Doc. 81181/J/21/0561 . Point # 4.7000038 (Page 05 of 22 )

Electronic Instrumentation in Hazardous Area: Flame proof concept applicable if Intrinsically safe instruments not possible.

We would like confirm that we will provide Ex-proof, ATEX - CCOE certified USM electronics instead of Intrinsically safe USM electronics as per this clause.

Accepted

55 Doc. 81181/J/21/0561 . Point # 4.9.1000039 (Page 06 of 22)

Electrical Power supply: 24V DC supply for field transmitter shall be through isolators provided in control panel which shall be in scope of contractor.

USM will power up the PT ,TT thru 2-wire type, hence isolators not required in panel. Kindly confirm its acceptance.

The PT and TT signal shall be connected to FC through isolators.

56 Doc. 81181/J/21/0559 . Point # 6.1.4 Minimum specs000043(Page 10 of 22)

81181/J/21/0559 . Point # 6.1.4 Minimum specs Ultrasonic flow meter: Transmitter 2- wire type

Requesting Tractebel - GAIL to accept the Ultrasonic Transmitter with 4-wire type instead of2-wire as per manufacturers design. The USM will be ex-proof and has ATEX/CCOE certification. Moreover USM will power up the PT ,TT thru 2-wire. We will follow the tender clause Doc. 81181/J/21/0561 . Point # 4.7

As per tender PT & TT are two wire type. Four wire type USM is acceptable.

57 Doc. 81181-L-16-0102 . Point # 6.1.4 Minimum specs000053( Page 20 of 22)

Metering system Length Requesting Tractebel- GAIL to confirm the distance availability ( maximum distance available) for the metering system.

Please refer Corrigendum # 1 S.N. 23

58 Doc. 81181/J/21/0561 . Point # 16.1.1000053( Page 20 of 22)

1. Meter has to be calibrated with Flow profiler + 10D up stream spool piece +Meter + 5D down stream spool piece.

4. "Transmitters (PT & TT) has to be calibrated with Flow computers in the same combination of installation"

We understand that only USM meter along with Profiler + 10 upstream & 5D down stream meter run need to be calibrated. Please clarify.

Bidder's Understanding is correct.

59 Doc. 81181/J/21/0561 . Point # 16.1.1000053( Page 20 of 22)

A zero flow "dry " verification test shall be performed. This test shall be fully documented by vendor and carried out in accordance with Sect- 6.3 of AGA 9. In addition to the dry verification, the USM should be "wet" calibrated. As a minimum , there shall be 6 calibration points covering the range and starting from Qmax.

Please clarify & confirm the starting calibration point shall be 10% Qmax( 0.1Qmax). Not from Qmax as mentioned in the tender.

Refer Ccorrigendum # 1, S.No. 21.

60 Doc. 81181/J/21/0561.000065

APPENDIX - 5 DATA Sheet Ultrasonic Flowmeter: Transducer body mtl: ASTM A 182 F 316

Requesting Tractebel - GAIL to accept the Manufacturers standard suitable to this application. The transducer material shall be suitable for the given process condition.

61 Doc. 81181/J/21/0561.000065

APPENDIX - 5 DATA Sheet Ultrasonic Flowmeter:

24 . Flow Transmitter: Smart compatible with HART

32. Housing : SS 316

Requesting GAIL-Tractebel to accept the following two points. ( Only selective bidders can supply & AGA-9 does not mandate the same) This clause limiting the open participation of more USM - OEMs.

24. Please note the USM Flow transmitter shall not necessarily be Smart/HART compatible. Please allow us to quote the USM certificated by NMI/PTB/CEECI /etc.. For Custody metering. HART transmitter only selective vendors can supply.

32. Flow transmitter housing shall be manufacturers standard certified for custody approval byNMI/PTB/CEESI/ etc.. Kindly accept the one with standard Die cast aluminium instead of SS 316.

Accepted but flow computer should be selected in such a way that it can communicate with USM with proper protocol.

Refer Corriegendum # 1, S.No. 25

62 Doc. 81181/J/21/0561.000065

APPENDIX - 5 DATA Sheet Ultrasonic Flowmeter:

Recommended Vendors for Ultrasonic flow meters(USM)

Requesting Tractebel-GAIL to approve GE make Ultrasonic Flow meter for this project. GE make USM was already listed in other GAIL projects ( JP kenny / Chaisa -Jajjar-Banmoli pipe line Project). GE meters are certified by NMI/PTB/CEECI for custody metering as per AGA-9. Also it has W&M approval of various countries for Custody metering. Kindly include "GE Sensing" name in the vendor list.

Tender condition prevails

Page 4 of 6

Sr. No. Clause no. Description Bidder’s Query/Clarification TE Reply

REPLY TO PRE BID QUERIES – 1SUPPLY OF METERING SYSTEM FOR DVPL-II

DATE : 23/03/09Tender doc. no. :81181/G/09/0005e-tender no. : 8000000869Owner : GAIL

63 Doc. 81181/G/94/005. 000066

Flow computer: 19. Battery back up: Min 72 hrs.

1. Please clarify whether Flow computer need to be powered thru UPS for 72 hrs back up.

2. Also confirm what would be the distance between USM and Panel to estimate the cabling cost.

This is flow computer's internal battery back up for its memory.

64 Doc. 81181/G/94/005.89

List of Recommended Vendors: NOTE( ):

"This is only recommended vendor list, Contractor may suggest other qualified vendor's name/instrument items/eqpts other than the above mentioned list." " Any other Qualified party or an Original Manufacturer subject to purchase approval".

"GE Sensing" being the Original Manufacturer of Ultrasonic Flow meters for Custody metering and GE meters are approved by NMI/PTB/CEECI/etc.. And has approval of W&M of several countries, requesting Tractebel-GAIL to include "GE Sensing" in the approved vendor list of USM for this project.

GE meters are already approved in the vendor list of JPKenny- GAIL (Chainssa-Jajjar-Banmoli Pipe line project)

Tender Conditions Prevails.

65 Page 000009 (page 05 of 09)

Bid Evaluation Criteria. 5.1.1 GE Sensing - India being the Indian subsidiary of GE Sensing, Ireland(Original Manufacturer of Ultrasonic custody flow meter), whether GE Sensing- India can submit the bid in its letter head on account of our corporate policy. In this case GE Sensing India will only submit the bid documents to GAIL through e- tender, however all BEC back up documentation pertaining to Original Manufacturer, Order placements & execution of the project will be by GE Sensing, Ireland (the original manufacturer). Tender will be submitted /uploaded through E- tender using GE Sensing -India vendor code with its digital signature. Requesting GAIL/Tractebel to accept this. We wish to mention herewith that GE sensing India works in this fashion with all PSU's including EIL/IOCL and even GAIL plants.

Bidder should meet Bid Evaluation Criteria in TOTO.

The bidder or his proposer of ultrasonic flow meter and flow computer shall have designed , manufactured , tested and supplied the ultrasonic flow meter and Flow computer of similar type/model as being offered, within the last seven(7) years reckoned from bid due date. We understand that bidder or proposer of ultrasonic flow meter shall have supplied Ultrasonic meter & flow computer ( any make/model) for similar gas metering application.Also " similar type /model" as mentioned in the tender shall be applicable to Ultrasonic Flow meter only and not for the flow computer, because all Ultrasonic flow meter manufactures are not manufacturing flow computers. In this case we understand that Ultrasonic meter shall be of 16"/600# supplied for similar application & the same should have been hooked up with any make/model of flow computer certified for Natural Gas custody metering. Kindly confirm.

Further to this we would also like to mention that GE Sensing Ireland may not have supplied theFlow computer along with the qualified model of flow meter as applicable to this tender, however our UFM has been integrated with the customer's flow computer and we have the letterfrom the customer that GE Sensing UFM is working with flow computer with satisfactory performance. Please confirm formally if this is acceptable to BEC criteria.It shall also not be out of context to mention herewith that the intend behind this is to establish the capability of the supplier both technically and commercially and not to bind him to be a manufacturer and supplier of all items under the requirement.

67 Doc. 81181/J/21/0561. 85

APPENDIX - 5 Transducer body mtl: ASTM A 182 F 316 Requesting Tractebel - GAIL to accept the GE standard Transducer body material : Titanium , Material Certs as per EN 10204 3.1.B. This issuperior than Stainless steel.

The transducer material shall be suitable for the given process condition.

68 5.1.2 5. Bid Evaluation Criteria Vol. I of II

We understand that PTR from bidder or his proposed supplier will be required for similar Size, Rating & Type for USM & Flowcomputer, asked in the tender MR. Further both Meter & Flowcomputer should be supplied in a single order. Please confirm that our understanding is correct.

Tender conditions prevail.

69 Description of Goods & Services

P&IDVol. II of II

We understand that we have to supply additional communication port for existing GC. Please provide the detail of existing GC like Make, Model No. etc.

Please refer reply S.N.21 & Corrigendum # 1 S.N. 6

70 Clause 4.7 Electronic Instrumentation in Hazardous area ; Page 38

4.0 Design Principles We understand that as per latest AGA-9 Pt. no.4.5.3; USM must have the certification for both Intrinsically Safe & Explosion Proof as well. Please confirm that our understanding is correct.

Please Refer Clause No. 4.7 of PTS Instruments

71 Data Sheet of Ultrasonic Meter Page no. 65

Data Sheet of Ultrasonic Meter We understand that, a) USM application will be Uni-Directional.Please confirmb) As USM is stand alone device & communicating with flow computer only, via serial serial link for transfering all the diagonostic & other process related measurement information. Hence HART may not be required.Please confirmd) In our USM Transducer material is SS, which is perfectly suitable for the application will also be acceptable. Please confirm.e) As per the latest AGA-9; one of the following output will be required in USM i) Pulse Output ii) Serial Output , RS 232 / RS 485 iii) 4-20 ma OutputPractically, Serial & Pulse out put will full-fill the requirement, because as per AGA-9, the flow calculation in flow computer will be done as per AGA-7, hence dual pulse frequency output is required & for diagnostic information serial O/P is required, hence we understand that 4-20ma may not be used & required. Please confirmf) We understand that as a option, meter should have facility for direct connectivity with GC. Please confirm

a) Bidder's Understanding is correct.b) Vender to follow USM data sheet

d) It is acceptable provided suitable for the offered process application.e) Accepted but flow computer should be selected in such a way that it can communicat with USM with proper protocol

f) Not required

Tender Condition are explictily clear. Page 000009 (page 05 of 09)

66 Bid Evaluation Criteria. 5.1.2

Page 5 of 6

Sr. No. Clause no. Description Bidder’s Query/Clarification TE Reply

REPLY TO PRE BID QUERIES – 1SUPPLY OF METERING SYSTEM FOR DVPL-II

DATE : 23/03/09Tender doc. no. :81181/G/09/0005e-tender no. : 8000000869Owner : GAIL

72 Data Sheet of Flow Computer; Page no. 66

Data Sheet of Flow Computer We understand that as Flow computer will be connected to RTU through RS 485 & there is no. controlling device like FCV etc.. Hence in 4 nos. analog output from Flow computer will be sufficient. Please confirm that our understanding is correct.

Please refer Corrigendum # 1, S.N. 19

73 Data Sheet of Pressure Transmitter a) We understand that specially for metering Gail is using Pressure Transmitter with an accuracy of +/- .04%. Please confirm the accuracy requirementb) We understand that Metering PT & TT signal shall be 4-20mA DC (2wired) superimposed with digital signal (HART) from SMART PT & TT representing the line pressure & temperature.

a) Please refer Corrigendum # 1, S.N. 12

b) Bidder's Understanding is correct

74 Laptop / Printer Supply Scope We understand that we have to supply 1 no. Laptop & 1 no.Dot Matrix Printers for both Flow Computers.

Laptop quantity is One No. while One No printer is required for each flow computer

75 G.A. Drawing Page no. 163

G.A. Drawing Page no. 163 a) In attached G.A. dia. 4 nos. spools has shown, however same can be done with 3 nos. spool also, we request you to provide revised GA accordingly.b) We understand that the counter flanges will not be in our scope, Please confirm that our understanding is correct.

a) Please refer Corrigendum # 1, S.N. 23

b) Bidder's Understanding is correct

For and on Behalf of GAIL (India) Limited