Compresores semihermticos DISCUS

Gua de Aplicacin

Indice1 2 3 Informacin General de Seguridad ............................................................................................................ 3 Validez de este manual .............................................................................................................................. 3 Entrega....................................................................................................................................................... 4 3.1 Entrega estndar:.................................................................................................................................. 4 3.2 Embalaje ............................................................................................................................................... 4 3.3 Transporte............................................................................................................................................. 4 Caractersticas de Diseo .......................................................................................................................... 4 4.1 Construccin ......................................................................................................................................... 4 4.2 Presiones mximas de funcionamiento ................................................................................................ 6 4.3 Enfriamiento interno del compresor ...................................................................................................... 6 4.4 Enfriamiento externo del compresor ..................................................................................................... 6 4.5 DEMAND COOLING ............................................................................................................................. 6 4.6 Aceites lubricantes ................................................................................................................................ 7 4.7 Bomba de aceite ................................................................................................................................... 7 4.8 Presostato diferencial de aceite............................................................................................................ 7 4.9 Circulacin del aceite ............................................................................................................................ 8 4.10 Nivel de aceite....................................................................................................................................... 8 4.11 Presin de aceite .................................................................................................................................. 9 Arranque..................................................................................................................................................... 9 5.1 Prueba de fugas.................................................................................................................................... 9 5.2 Vaco (Deshidratacin).......................................................................................................................... 9 5.3 Carga de refrigerante ............................................................................................................................ 9 5.4 Limpieza del circuito.............................................................................................................................. 9 Informacin Elctrica................................................................................................................................ 10 6.1 Conexiones elctricas ......................................................................................................................... 10 6.2 Arranque directo.................................................................................................................................. 10 6.3 Arranque estrella-tringulo (Y/ ) - Cdigo de motor E ....................................................................... 10 6.4 Arranque Part-Winding (devanado partido) (YY/Y) - Cdigo de motor A ........................................... 10 6.5 Nuevo motor part winding para los compresores de 8 cilindros - Cdigo de motor B ....................... 10 6.6 Proteccin del motor ........................................................................................................................... 10 6.7 Indice de proteccin de la caja de terminales segn IEC 529............................................................ 11 Informacin en la placa de caractersticas............................................................................................... 11 7.1 Placa de caractersticas D2D, D3D ................................................................................................... 11 7.2 Placa de caractersticas D4D - D8D .................................................................................................. 11 Nomenclatura de compresores Discus .................................................................................................... 12 Nomenclatura de compresores Discus TWIN.......................................................................................... 13 Datos tcnicos de accesorios .................................................................................................................. 14 Conexiones del compresor Discus........................................................................................................... 15 Pares de Apriete (Nm) ............................................................................................................................. 18 Instalacin del Ventilador ......................................................................................................................... 19 Arranque Descargado .............................................................................................................................. 20 14.1 Compresores D2D y D3D ................................................................................................................... 20 14.2 Compresores D4D D8D ................................................................................................................... 21 14.3 Vlvula de Retencin D2D D8D....................................................................................................... 21 Control de Capacidad............................................................................................................................... 24 15.1 Moduload para Compresores D3D ..................................................................................................... 24 15.2 Seleccin del Control de Capacidad................................................................................................... 25 15.3 Control de Capacidad Moduload D3D Factores de carga parcial 134a HM..................................... 26 15.4 Control de Capacidad Moduload D3D Factores de carga parcial R134a HH .................................. 27 15.5 Control de Capacidad Moduload D3D Factores de carga parcial R404A HM.................................. 28 15.6 Control de Capacidad Moduload D3D Factores de carga parcial R404A LXZ.................................. 29 15.7 Control de Capacidad Moduload D3D Factores de carga parcial R22 HM ...................................... 30

4

5

6

7 8 9 10 11 12 13 14

15

D6.3.2/0203/S

1

16

17 18 19 20 21 22

23 24 25

26 27

28

Control de Capacidad D4D D8D ........................................................................................................... 31 Juntas en las culatas de control de capacidad de compresores semihermticos de 4-6-8 cilindros . 32 Seleccin del Control de Capacidad, R134a ...................................................................................... 33 Control de Capacidad D4D D8D Rango de Aplicacin R134a...................................................... 34 Seleccin del Control de Capacidad, R22 .......................................................................................... 35 Control de Capacidad D4D D8D Rango de Aplicacin R22 .......................................................... 36 Seleccin del Control de Capacidad, R404A...................................................................................... 37 Control de Capacidad D4D D8D Rango de Aplicacin R404A ..................................................... 38 Seleccin del Control de Capacidad, R407C ..................................................................................... 40 Control de Capacidad D4D D8D Rango de Aplicacin R407C (pto medio) ................................... 41 Platos de Vlvulas Discus D4D - D6D ..................................................................................................... 42 Compresores TWIN D44D - D66D........................................................................................................... 42 18.1 Nueva Cmara de Aspiracin ............................................................................................................. 43 Resistencia de Crter............................................................................................................................... 43 19.1 Resistencia 70 W / 100 W y vaina. ..................................................................................................... 44 19.2 Resistencia 200 Watt ......................................................................................................................... 44 Bomba de Aceite ...................................................................................................................................... 45 20.1 Adaptador............................................................................................................................................ 46 20.2 Junta de la bomba de aceite............................................................................................................... 46 Control de Presin Diferencial de Aceite OPS1....................................................................................... 47 TM Nuevo sistema de seguridad de la presin de aceite SENTRONIC+ .................................................. 48 22.1 Datos Tcnicos ................................................................................................................................... 48 22.2 Operacin............................................................................................................................................ 48 22.3 Montaje ............................................................................................................................................... 49 22.4 Conexin elctrica............................................................................................................................... 49 22.5 Prueba de funcionamiento .................................................................................................................. 49 22.6 Mdulos y Sensores Intercambiables de Sentronic & Sentronic+............................................... 50 + 22.7 Conexin del nuevo mdulo Sentronic a un sensor antiguo ............................................................. 50 + 22.8 Conexin del mdulo antiguo Sentronic al nuevo sensor Sentronic ................................................. 51 Presostato Diferencial de Aceite .............................................................................................................. 52 23.1 Presostato Diferencial de Aceite Alco FD 113 ZU, D2D D8D.......................................................... 52 Instalacin Elctrica ................................................................................................................................. 53 Esquemas Elctricos................................................................................................................................ 55 25.1 Posicin de las pletinas del Motor ...................................................................................................... 55 25.2 Modulo INT69 y INT69 TM.................................................................................................................. 56 25.3 DEMAND COOLING ........................................................................................................................... 56 25.4 Control de presin diferencial de aceite (OPS1) ................................................................................ 57 Control de Presin de Aceite SENTRONIC ............................................................................................. 58 26.1 Presostato Diferencial de Aceite- ALCO FD 113 ZU .......................................................................... 58 26.2 Ventiladores 60 Watt........................................................................................................................... 59 Causas de Avera..................................................................................................................................... 60 27.1 Problemas de lubricacin.................................................................................................................... 60 27.2 Dilucin del aceite ............................................................................................................................... 60 27.3 Migracin del refrigerante ................................................................................................................... 60 27.4 Recalentamiento inadecuado de la aspiracin ................................................................................... 61 27.5 Formacin de cido............................................................................................................................. 61 27.6 Enfriamiento inadecuado del compresor ............................................................................................ 61 27.7 Altas temperaturas de descarga ......................................................................................................... 61 27.8 Motor quemado debido a sub-dimensionado de contactores............................................................. 61 27.9 Motor quemado debido a protectores puenteados o desconectados................................................. 61 Preguntas tcnicas de aplicacin............................................................................................................. 61 16.1 16.2 16.3 16.4 16.5 16.6 16.7 16.8 16.9

D6.3.2/0203/S

2

ImportanteLa instalacin, puesta en marcha y reparacin de los compresores COPELAND debe ser realizada nicamente por personal cualificado y autorizado. El principal propsito del presente manual es el de asesorar al instalador y proporcionar a est la informacin tcnica necesaria para la correcta aplicacin de nuestros compresores de la serie Discus. En el software de seleccin select y en la documentacin tcnica publicada que se encuentra en nuestra Web www.ecopeland.com, hallar informacin adicional. 1 Informacin General de Seguridad Los compresores Copeland adaptados para aplicaciones de refrigeracin o aire acondicionado slo deben utilizarse con los refrigerantes y aceites aprobados para los mismos. No est permitido realizar ninguna prueba a un compresor si ste no se encuentra formando parte de un sistema frigorfico o dicho sistema no hubiese sido cargado previamente con alguno de sus refrigerantes aprobados. Es de vital importancia que, previamente al arranque del compresor, se asegure que la vlvula de servicio de descarga del mismo se encuentra completamente abierta. El caso omiso a esta recomendacin podra provocar severos daos en el compresor como consecuencia de la aparicin de altas presiones en el interior de sus culatas (motivadas por el cierre de la citada vlvula). Del mismo modo se deber prestar una atencin especial para que el compresor no comprima bajo ninguna circunstancia aire en lugar de refrigerante, al objeto de evitar los posibles daos provocados por el denominado efecto Diesel. Bajo la influencia de dicho efecto existe el riesgo de explosin de la mezcla constituida por el aire aspirado y el aceite, debido a las altas temperaturas generadas durante la compresin de la misma. Por otro lado, y durante el funcionamiento normal del compresor, se deber de evitar todo contacto de la piel con aquellas zonas del mismo cuya temperatura pudiera dar lugar a daos por quemaduras graves. Las mximas presiones de trabajo indicadas en la placa de caractersticas del compresor se debern de respetar obligatoriamente no debiendo ser superadas bajo ninguna circunstancia (Ver pag. 5). El compresor siempre formar parte de un sistema que se encuentra bajo la influencia de la presin y por lo tanto sujeto a las normas de seguridad correspondientes (EN 378). 2 Validez de este manual Este manual nicamente se aplica a los compresores Discus fabricados posteriormente al 01 de Abril de 1991, (numeros de serie 91D y posteriores). Es valido para todos los refrigerantes aprobados. Los compresores D2D y D8D no fueron modificados. El quinto dgito de la denominacin del compresor identifica la generacin de los mismos. Mientras que los compresores D4D y D6D con un nmero 3 se corresponden con aquellos modelos fabricados entre Abril de 1991 y Abril de 1999 (numeros de serie comprendidos entre 91D a 99D), el numero 4 identifica a aquellos otros producidos desde Mayo de 1999 en adelante. (99E) Los accesorios y repuestos de los compresores D4D y D6D no son intercambiables con los modelos anteriores. Las posiciones de montaje de los sistemas de control de capacidad y arranque descargado han sido modificadas. Las antiguas cmaras de aspiracin comn de los compresores TWIN no pueden ser utilizadas con los modelos fabricados a partir del 1 de Abril de 1991. Algunos repuestos para compresores D3D*4 y D3D*5 no son intercambiables, la versin*4 fue utilizada en los modelos cuyos dgitos iniciales de su numero de serie se encontraban comprendidos entre 91D y 99K, mientras que la versin *5 se corresponde con aquellos otros cuyo nmero de serie comienza por 99L en adelante. El compresor es slo un componente mas que debe combinarse con muchos otros para formar un sistema de refrigeracin funcional y eficiente. Por lo tanto, toda la informacin de este manual se refiere unicamente a los compresores Discus equipados con sus accesorios y componentes estndar.

D6.3.2/0203/S

3

3 Entrega A la recepcin del compresor, recomendamos que se verifique que la entrega se encuentra completa y adems intacta. Cualquier deficiencia encontrada deber comunicarse por escrito inmediatamente. 3.1 Entrega estndar: - vlvulas de servicio de aspiracin y descarga - carga de aceite, visor de aceite - kit de montaje - Ventilador de culata (slo modelos de baja temperatura) - protector del motor - carga de gas inerte 3.2 Embalaje Todos los compresores se embalan individualmente y se suministran o bien de esta manera o dispuestos en palets, (dependiendo de su nmero y tamao). Los accesorios, dependiendo del tipo en cuestin de que se trate, podrn ser entregados ya sea sueltos o montados en el compresor. Las bobinas de las vlvulas solenoide de control de capacidad o arranque descargado nunca se entregan montadas y los ventiladores de culata se entregan en cajas separadas. Se deber poner especial cuidado cuando se apilen los compresores uno encima de otro. Si se apilan a mayor altura que la mxima recomendada en la figura adjunta existe una gran probabilidad de que ocurran graves accidentes. El embalaje debe mantenerse siempre seco en todo momento! 3.3 Transporte Los compresores slo debern moverse con aquellos equipos adaptados para soportar el peso de los mismos. Por razones de seguridad deberan instalarse una o dos argollas en el compresor antes de comenzar a mover el mismo (1/2" - 13 UNC)! Consultar tambin los dibujos de la pgina 4 para ver como aplicar de un modo seguro otros mtodos y sistemas de elevacin. Los compresores D3D no deberan nnca ser levantados empleando solamente una cuerda, ya que la forma del compresor podra favorecer que sta resbalase. A fin de evitar fugas de refrigerante u otros daos en los compresores, estos no deberan levantarse en ningn caso utilizando como apoyos las vlvulas de D2 D3 servicio o otros accesorios. 4 Caractersticas de Diseo Cada compresor se entrega con cuatro muelles amortiguadores coloreados. Los muelles permiten D4 D8 el movimiento del compresor durante los arranques y paradas y evitan que las vibraciones se transfieran a la bancada del mismo durante su funcionamiento. Los muelles se seleccionan de acuerdo con la tabla de la pgina 4. Un compresor tambin puede montarse sin muelles. Para asegurar la lubricacin adecuada de todas las partes mviles, el compresor debe instalarse horizontalmente en los dos ejes del plano.Los compresores TWIN estn montados sobre los rales con amortiguadores de caucho. Si la instalacin requiere un nivel muy alto de absorcin de vibraciones, debern montarse amortiguadores adicionales entre los rales y la base de apoyo que aseguren el nivel requerido. 4.1 Construccin Las caractersticas bsicas de construccin pueden verse en las fotos de la pgina 5.Todos los compresores vienen equipados con platos de vlvulas Discus que no pueden desmontarse. Para mantener intactas sus caractersticas, en el caso de avera o cambio del plato de vlvulas, siempre deber seleccionarse la junta adecuada que se encuentra entre dicho plato y el bloque. El espesor de la junta viene marcado en una lengeta exterior en la misma. Cada culata tiene una toma (1/8" - 27 NPTF) para la conexin de un presostato de alta. Antes de poner en marcha el compresor se debern instalar y probar correctamente todos los controles de presin y dispositivos de seguridad disponibles, teniendo cuidado de no sobrepasar las presiones mximas admisibles de dicho compresor. En los compresores Discus la culata completa se encuentra a la presin de descarga.

D6.3.2/0203/S

4

Compresor Tipo D2DC-50X (500) D2DD-50X (500) D2DL-40X (400DC) D2DL-75X (750) D2DB -50X (500DC) D2DB -75X (750) D3DA -50X (500DC) D3DA -75X (750) D3DC-75X (750DC) D3DC-100X (1000) D3DS -100X (1000DC) D3DS -150X (1500) D4DA -100X D4DF-100X (1000DC) D4DA -200X (2000) D4DH-150X D4DL-150X (1500DC) D4DH-250X(2500) D4DJ-200X D4DT-220X (2200DC) D4DJ-300X (3000) D6DH-200X D6DL-270X (2700DC) D6DH-350X (3500) D6DT-300X (3000DC) D6DJ-300X D6DJ-400X (4000) D8DL-370X D8DH-400X,500X (5000) D8DT-450X D8DJ-500X,600X (6000)D6.3.2/0203/S

Tamao Tamao

Color de los muellesex tremo motor extremo compr.

Posicin de transporte Posicin funcionamiento

A mm 30 30 30 30 30 30 30 30 30 30 30 34 34 34 34 34 34 34 34 34 34 34 34 34 48 48 48 48 48 48 48

B mm 35 35 35 35 35 35 35 35 35 35 35 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 51 51 51 51

Brida de transporte

Goma

2x granate

2x granate

2 x blanco

2x amarillo Gomas para compresores TW IN 2x verde 2x negro

Tacos de goma

2x azul

2x rojo 2x negro

2x plateado

5

En los compresores de simple etapa viene instalada una vlvula de seguridad con una capacidad de evacuacin superior a 50 m3/h. La apertura de esta vlvula depende de la diferencia de presiones entre alta y baja y responde a una presin diferencial de 30,0 bar. 4.2 Presiones mximas de funcionamiento Lado de alta presin (HP) 28,0 bar Lado de baja presin (LP) 22,5 bar (durante la parada)

4.3 Enfriamiento interno del compresor Todos los compresores Discus se enfran por el paso de los gases de aspiracin a travs y alrededor del motor. 4.4 Enfriamiento externo del compresor Dependiendo de las condiciones de trabajo algunos compresores necesitan un ventilador adicional. En la pgina 18 se pueden encontrar las instrucciones de montaje de dicho ventilador. Informacin adicional ms especfica sobre los requerimientos de aplicacin de compresores se encuentra disponible en el software de seleccin. 4.5 DEMAND COOLING El trmino DEMAND COOLING, como su nombre indica, pretende expresar el concepto de inyeccin de lquido refrigerante bajo demanda. Si se desea realizar una instalacin de baja temperatura con R22, los siguientes compresores pueden ser equipados con el correspondiente kit DEMAND COOLING D2DL* 400 D4DF * 1000 D2DB* 500 D4DL* 1500 D3DA* 500 D4DT* 2200 D3DC* 750 D6DL* 2700 D3DS* 1000 D6DT* 3000 * El quinto dgito de la denominacin del modelo debe ser 3 para D4D y D6D, y 4 para D3D. En los folletos C6.4.1, C6.4.2 y C6.4.3. puede encontrarse informacin ms detallada sobre este sistema. Recordatorio: No esta permitido el uso de R22 en Europa para nuevas instalaciones de refrigeracin.

D6.3.2/0203/S

6

4.6 Aceites lubricantes Los siguientes aceites lubricantes de refrigeracin se encuentran actualmente aprobados por Copeland: Aceites Ester para R 134a, R407C y R404A / R507 ICI Emkarate RL 32 CF (carga original, utilizado tambin para recargas y ajustes) Mobil EAL Arctic 22 CC (usado para ajustar y recargar) En el caso de que se desee utilizar el aceite ICI Emkarate RL 32S se deber tener en cuenta que solo se podr emplear una cantidad limitada de ste para ajustar la carga original de aceite del compresor. Todos los compresores que incorporan aceite ester se encuentran marcados con una X en su nomenclatura. Estos compresores tambin pueden trabajar con R22. Aceites minerales utilizados con R 22 R. Fuchs Fuchs Reniso KM 32 Sun Oil Co. Suniso 3 GS Texaco Capella WF 32 Shell Shell 22-12

ppm 1500 POE 1000 500 mineral oil 50 100 150 200 250K11.0/0593

300 h

Este diagrama compara las caractersticas higroscpicas del aceite ster Arctic 22 CC con el tradicional aceite mineral (absorcin de humedad en ppm a 25 C y con una humedad relativa del 50%). Los refrigerantes sin cloro slo se deben utilizar con aceites poliolester, tambin conocidos tradicionalmente como aceites ster. El aceite ster es muy higroscpico y sensible a la humedad. La proporcin de dicha humedad en el aceite es determinante en la estabilidad qumica del mismo. Por esta razn, es esencial montar un filtro secador en la instalacin que reduzca el nivel de humedad en la misma por debajo de 50 ppm (medida despus de 48 horas de funcionamiento). En general los aceites ster requieren de un manejo ms cuidadoso con una mnima exposicin al ambiente. 4.7 Bomba de aceite El funcionamiento de las bombas de aceite que se usan en los compresores Discus es independiente de su sentido de giro. Estn diseadas de modo que se puede acoplar en las mismas indistintamente los controles de seguridad de aceite SENTRONIC,OPS1 o un presostato diferencial de aceite estndar. En las pginas 45 a 52 se encuentran los componentes bsicos de estos controles y sus instrucciones de montaje. 4.8 Presostato diferencial de aceite El presostato diferencial de aceite interrumpe la alimentacin elctrica del compresor cuando la diferencia de presin entre la salida de la bomba de aceite y el crter es demasiado baja. Si la presin diferencial de aceite cae por debajo del valor mnimo aceptable, es imperativo que el presostato detenga el compresor despus de un retardo de 120 segundos. El presostato tiene que ser rearmado manualmente una vez se haya eliminado el problema que provoc el disparo del mismo. El control de la presin diferencial de aceite con un presostato de seguridad aprobado, es una condicin necesaria para la aplicacin de la garanta del compresor!D6.3.2/0203/S

7

Las especificaciones para los presostatos diferenciales de aceite son las siguientes: Presin de corte: 0.63 0.14 bar Preson de arranque: 0.9 0.1 bar Retardo: 120 15 sec. Los siguientes presostatos se encuentran actualmente aprobados: Fabricante ALCO CONTROLS Tipo

FD 113 ZU P 30-5845* Ranco P 30-5842* Danfoss MP 55 P 45 NCA-12 P 45 NCB-3 Penn P 45 NAA-3 P 45 NCA-9104 LG 21-2500 PD 21-1006 Robertshaw PD 21-7501 PD 21-5001 *Conexin abocardada 4.9 Circulacin del aceite El retorno de aceite, que llega a la vlvula de servicio mezclado con el gas de aspiracin, es en primer lugar filtrado y separado del citado gas en el compartimento del motor del compresor como fase previa a su llegada al interior del crter del mismo. Para alcanzar su destino final el aceite deber an atravesar una vlvula de retencin de seguridad que se encuentra en la particin entre ambas zonas interiores (compartimento y crter). La funcin de esta vlvula es la de prevenir que el aceite pueda retroceder, y por tanto salir del crter, en el caso de que la presin existente en ste fuera muy superior a la que se encontrase en el compartimento del motor (situacin caracterstica durante el arranque). La citada vlvula siempre realizar su funcin y por tanto permanecer cerrada a menos que la presin a ambos lados de la misma se iguale. Durante el arranque y funcionamiento normal esta igualacin se encuentra asegurada como consecuencia de la puesta en escena de una segunda vlvula de retencin que conecta el crter del compresor con la zona de aspiracin interna del mismo. Esta segunda vlvula dispone de un taladro de dimetro muy pequeo en la placa de su base que provoca que la presin de dicho crter disminuya muy lentamente (efecto venturi), especialmente durante el arranque del compresor, con lo que se asegura as que la cantidad de espuma en el aceite sea mnima. 4.10 Nivel de aceite Todos los compresores se entregan con una cantidad suficiente de aceite en el crter del mismo para su funcionamiento normal. El nivel de aceite debe comprobarse tras hacer funcionar el compresor hasta su rgimen nominal y luego comparando la lectura de la mirilla con el diagrama correspondiente. El nivel puede comprobarse tambin una vez el compresor haya parado (a los 10 segundos de dicha parada). Para compresores D4D...D8D se puede admitir un nivel de aceite superior cuando se emplean reguladores de nivel, ya que es de esperar que el separador de aceite reduzca la circulacin excesiva de ste a travs de la instalacin

D2D / D3DMax

D2D / D3DMin

D4D D8DMax

D4D D8DMin

Z.8.03.00

D6.3.2/0203/S

8

4.11 Presin de aceite La presin de aceite a la salida de la bomba podr ser considerada normal cuando se encuentre comprendida entre 1,05 y 4,2 bar por encima de la presin del crter. La presin neta de aceite puede obtenerse conectando un manmetro a la bomba de aceite y otro al crter del compresor (empleando un accesorio en T en el lugar de los tapones 3 o 5 en el crter del compresor) o a su vlvula de servicio de aspiracin.En caso de anomalas de funcionamiento (p.ej. un bloqueo del filtro interno de aspiracin del compresor), se deber de tener en cuenta que la presin medida en la vlvula de servicio del compresor podr diferir mucho del valor real existente en el crter del mismo. 5 Arranque El compresor unicamente deber ponerse en marcha una vez se haya equipado ste con los accesorios adecuados, segn las indicaciones de nuestra documentacin tcnica y considerando la aplicacin prevista. En la pgina 13 se puede encontrar informacin sobre accesorios y otros componentes. Los pares de apriete de los tornillos aparecen en la pgina 18. Todas las juntas deben lubricarse antes de su montaje con la excepcin de las juntas Wolverine. Tambin deben lubricarse los anillos tricos. Un compresor nunca debe hacerse funcionar ms all de su rango de aplicacin aprobado! Comprobar sto consultando la hoja de datos tcnicos del mismo. Para evitar daos en el motor, el compresor nunca debe arrancarse, ni deben realizarse pruebas de meguer en alta tensin cuando se ha procedido a hacer vaco en el interior del mismo. Para asegurar una larga vida al compresor, es importante seguir las siguientes indicaciones: 5.1 Prueba de fugas Las vlvulas de servicio del compresor deben permanecer cerradas durante las pruebas de presin para evitar as que entre aire y humedad al interior del mismo. La presin empleada (nitrgeno seco) no deber exceder los 20,5 bar, siempre y cuando la mxima presin de cualquier otro componente del circuito no sea inferior, en cuyo caso dicha presin mas baja, se deber corresponder con esta a aplicar durante la realizacin de la prueba. 5.2 Vaco (Deshidratacin) Para realizar esta operacin de una manera adecuada, en primer lugar se deber hacer vaco en la instalacin hasta 0,3 mbar manteniendo las vlvulas del compresor completamente cerradas. A continuacin y una vez finalizada esta operacin, se proceder a hacer vacio al compresor. La carga de aire seco del compresor se encuentra a una presin de 1 a 2,5 bar para garantizar la perfecta estanqueidad del mismo. No abrir nunca el compresor cuando ste se encuentre bajo presin y prestar una especial atencin cuando se extraigan los tapones para conectar un manmetro o ajustar la carga de aceite, pues podra suceder que estos salieran despedidos y se produjeran salpicaduras de aceite. 5.3 Carga de refrigerante La carga de refrigerante liquido debe hacerse a travs de algn accesorio en la vlvula de servicio del recipiente o en la lnea de lquido. Durante esta operacin se recomienda el uso de un filtro-secador en la tubera de carga. 5.4 Limpieza del circuito Durante la instalacin del sistema todas las soldaduras deberan realizarse en un ambiente de gas inerte (oxigeno libre de nitrgeno a baja presin) para prevenir la formacin de oxido en el interior de los tubos y en los adaptadores. Todos los componentes y materiales utilizados debern ser aptos para su aplicacin en los sistemas de refrigeracin. Es necesario que todas las impurezas (suciedad, escamas de soldadura, fundente, escorias, limaduras, etc.) que pudieran encontrarse en el interior del circuito frigorfico, se eliminen de ste previamente a la puesta en marcha del compresor. Ello evitar la aparicin de posibles averas en el futuro. Muchas de estas impurezas son tan pequeas que pueden incluso pasar a travs del filtro que se encuentra en el lado de aspiracin interno del compresor, o bien producir la obstruccin del mismo ocasionando elevadas cadas de presin. Por este motivo recomendamos el uso de un filtro externo, adecuadamente dimensionado en la lnea de aspiracin, (con una cada mnima de presin) en todas aquellas instalaciones que deban realizarse in situ o en aquellos otros casos en los que no pueda garantizarse una limpieza exhautiva en las mismas.

D6.3.2/0203/S

9

6

Informacin Elctrica

6.1 Conexiones elctricas Todas las cajas de conexiones de los compresores contienen esquemas elctricos de los mismos. Antes de conectar el compresor asegurarse de que el voltaje de alimentacin, las fases y la frecuencia coinciden con los valores dados en la placa de caractersticas. Las pletinas deben conectarse de acuerdo con el mtodo de arranque empleado. Para ms detalles ver la pgina 57. 6.2 Arranque directo Todos los compresores pueden arrancarse de forma directa. 6.3 Arranque estrella-tringulo (Y/ ) - Cdigo de motor E Este tipo de arranque nicamente es viable si el voltaje de red y el voltaje nominal del motor en conexin tringulo son idnticos. Para realizar este tipo de arranque se debern eliminar las pletinas de la placa de bornes e instalar un sistema de arranque descargado que garantice el mismo. 6.4 Arranque Part-Winding (devanado partido) (YY/Y) - Cdigo de motor A Estos motores se componen de dos devanados independientes que funcionan en paralelo (2/3 + 1/3) cada uno de los cuales se encuentra conectado interiormente en estrella. Para realizar el correspondiente arranque PW los dos devanados se conectarn a la alimentacin elctrica secuencialmente mediante sendos contactores y con una demora de tiempo de aproximadamente 1 segundo 0,1. El primer devanado que debe conectarse siempre se corresponder con el devanado 2/3 (bornes 1-2-3) al objeto de reducir la carga en la lnea y limitar por tanto la intensidad durante el arranque. Es imperativo que ambos devanados se conecten en la misma secuencia de fases. El arranque Part Winding slo puede garantizarse con el montaje de un equipo de arranque descargado. Para la realizacin de un arranque directo se deber de realizar la conexin acorde a las indicaciones dadas en el correspondiente esquema elctrico de la caja de conexiones y empleando las pletinas que se incluyen en la misma. 6.5 Nuevo motor part winding para los compresores de 8 cilindros - Cdigo de motor B Desde Enero de 1994, los compresores semihermticos de 8 cilindros incorporan un nuevo motor part winding. Principalmente y con respecto a la versin anterior de este tipo de motor (cdigo A), el nuevo modelo se caracteriza por poseer un mayor par de arranque, tanto para el caso de que dicho arranque se haga de forma directa como en modo part winding. Adems, a fin de mejorar sus caractersticas, se ha subdividido todo el devanado del motor de tal modo que 3/5 partes de toda la corriente fluyan a travs de los terminales 1-2-3 y 2/5 partes a travs de los terminales 7-8-9. A pesar del aumento considerable del par de arranque, la intensidad de rotor bloqueado (devanado completo) y la intensidad mxima de trabajo no han sido alteradas. La alimentacin de este tipo de motor elctrico a travs de los terminales 1-2-3 (sin puentes), y por tanto la realizacin efectiva de un arranque part winding, supone que la intensidad de arranque alcance tan solo un valor de un 68% con respecto al valor total de la intensidad que se obtendra en un arranque directo. Tras la conexin del primer devanado, y con una demora de 1 +- 0.1 segundos, se deber alimentar el segundo devanado a travs de los terminales 7-8-9. Si el arranque se realizase empleando inicialmente el segundo devanado (terminales 7-8-9 sin puentes) en lugar del primero, la corriente de arranque en este caso podra reducirse hasta un 54%. La distribucin de la corriente total a travs de ambos devanados es independiente de la carga: Devanado en los terminales 1-2-3 60% Devanado en los terminales 7-8-9 40% Atencin: A fin de no poner en peligro el motor, la conexin del primer y el segundo devanado a las fases L1, L2 y L3 debe ser idntica. Los terminales del primer y segundo devanado deben de conectarse en la misma secuencia de fases. 6.6 Proteccin del motor Todos los compresores trifsicos con una W en la designacin del cdigo de su motor estn provistos de un sistema de proteccin por termistores. La relacin existente entre la temperatura y la resistencia del termistor es la propiedad utilizada para medir la temperatura de los devanados. Los compresores Discus D2D y D3D utilizan tres termistores conectados en serie y embebidos en el interior del devanado del motor. Los motores de los compresores D4D, D6D y D8D vienen equipados con dos cadenas de tres termistores cada una. En todos los casos la conexin final de la cadena de sensores se lleva a unas bornas en la caja de terminales y de all al mdulo electrnico incorporado en la misma (INT 69 para D2D y D3D,INT69 TM para D4-D8).El mdulo electrnico procesa la resistencia de los termistores y en funcin delD6.3.2/0203/S 10

valor que adopta la misma actua sobre la maniobra de control del compresor. El mdulo INT69 TM tiene un retardo incorporado de 5 minutos. El voltaje nominal del mdulo es de 200 - 240 V / 1 ~ /40-60 Hz. Hay disponibles bajo demanda mdulos para otros voltajes. El voltaje mximo de prueba para los termistores es de 3V. La resistencia de la(s) cadena(s) de termistores en un compresor parado y que se encuentre a temperatura ambiente debe ser de < 750 ohms. 6.7 Indice de proteccin de la caja de terminales segn IEC 529 Modelo D2D D3D D4D D6D D8D Indice Opcin IP54 IP 56* IP54 IP 56* IP54 IP 56 IP54 IP 56 IP54 IP 56 *protector de sobrecarga externo

Los prensas instalados en fbrica reducen el ndice de proteccin a IP 41. 7 Informacin en la placa de caractersticas Toda la informacin relevante para la identificacin del compresor viene impresa en su placa de caractersticas. Para completar la misma slo ser necesario que el instalador escriba el tipo de refrigerante que pretenda utilizar. En todos los modelos se ha ampliado la notacin de la fecha de produccin que adems de mostrar el ao ahora indica tambin el mes: Enero = A, Febrero = B... Diciembre = L. Los compresores D2D y D3D tienen un campo marcado con un asterisco (*) que se usa para indicar esta informacin. Para los compresores D4D a D8D la citada indicacin del mes viene incluida en el nmero de serie. La placa de caractersticas comn de los compresores TWIN slo indica el modelo y el ao de fabricacin. Todos los dems detalles debern tomarse de las placas individuales de cada compresor. 7.1 Placa de caractersticas D2D, D3D

7.2

Placa de caractersticas D4D - D8D

D6.3.2/0203/S

11

8

Nomenclatura de compresores Discus DWM Copeland Compresor Discus, refrigerado por gas Proteccin electrnica con termistores y mdulo Kriwan en la caja de conexiones Volt 208-230 440-480 220-240 380-420 220-240 380-420 380-420 220-240 380-420 500-550 ~ 3 3 3 3 3 3 3 3 3 3 Hz 60 60 60 60 50 50 50 50 60 50

D2D A F B C D H L J T S

Desplazamiento -1 m/h / 1450 min / 50 Hz D3D D4D D6D 32.1 56.3 84.0 56.3 84.0 37.9 70.8 70.8 84.7 84.7 106 106 127 127

D8D

C D L

28.0 16.8 19.3 23.7

151 151 180 180

M R X Y

49.9 Aplicacin LT con ventilador (F, L, T) 1-9Variacin de modelo

Tamao de motor

Versin de compresor

D3DS* - 150X H AWM / D 000Nmero de cilindros

X 0

Compresor con aceite ster Compresor con aceite mineral

T E A B

Aplicacin D3D MODULOAD H HH + HM L L + LXZ

motor trifsico, voltaje nico motor trifsico Y (WYE) motor trifsico arranque part winding, fraccionamiento 2/3 - 1/3 motor trifsico arranque part winding, distribucin de corriente 60%-40%

D6.3.2/0203/S

12

9

Nomenclatura de compresores Discus TWIN

DWM Copeland Compresor Discus, refrigerado por gas Proteccin electrnica con termistores y mdulo Kriwan en la caja de conexiones Volt 208-230 440-480 220-240 380-420 220-240 380-420 380-420 220-240 380-420 500-550 ~ 3 3 3 3 3 3 3 3 3 3 Hz 60 60 60 60 50 50 50 50 60 50

D22D A F B C D H L J T S

Desplazamiento -1 m/h / 1450 min / 50 Hz D33D D44D D66D 64.2 113 168 113 168 75.8 142 142 169 169 212 212 254 254

D88D

C D L

56.0 33.6 38.6 47.4

302 302 360 360

M R X Y

99.8 Aplicacin LT con ventilador (F, L, T)

Tamao de motor

Versin de compresor

D88DH - 1000 X AWM / D 000Nmero de cilindros, compresor 1 Nmero de cilindros, compresor 2

X 0

Compresor con aceite ster Compresor con aceite mineral

T E A B

motor trifsico, voltaje nico motor trifsico Y (WYE) motor trifsico arranque part winding, fraccionamiento 2/3 - 1/3 motor trifsico arranque part winding, distribucin de corriente 60%-40%

D6.3.2/0203/S

13

10

Datos tcnicos de accesorios

Datos tcnicos de accesoriosArranque descargadoElectrovlvula Vlvula piloto V. de retencin 1

Compresor

Control capacidad

Resist. de crter (vatios)

Carga de aceite

Opcional D2DC-50X (500) D2DD-50X (500) D2DL-40X (400 DC) D2DL-75X (750) D2DB-50X (500 DC) D2DB-75X (750) D3DA-50X (500 DC) D3DA-75X (750) D3DC-75X (750 DC) D3DC-100X (1000) D3DS-100X (1000 DC) D3DS-150X (1500) D4DA-100X D4DF-100X (1000 DC) D4DA-200X (2000) D4DH-150X D4DL-150X (1500 DC) D4DH-250X (2500) D4DJ-200X D4DT-220X (2200 DC) D4DJ-300X (3000) D6DH-200X D6DL-270X (2700 DC) D6DH-350X (3500) D6DT-300X (3000 DC) D6DJ-300X D6DJ-400X (4000) D8DL-370X D8DH-400X D8DH-500X (5000) D8DT-450X D8DJ-500X D8DJ-600X (6000)1 2

MODULOAD MODULOAD MODULOAD MODULOAD MODULOAD MODULOAD

EVR 15 EVR 15 EVR 15 EVR 15 EVR 15 EVR 15 EVR 20 EVR 20 EVR 20 EVR 20 EVR 20 EVR 20 -

-

NRV 22S 22 70 NRV 22S 22 70 NRV 22S 22 70 NRV 22S 22 70 NRV 22S 22 70 NRV 22S 22 70 NRV 22S 22 70 NRV 28S 28 70 NRV 28S 28 70 NRV 28S 28 70 NRV 28S 28 70 NRV 28S 28 70

-

I 2,3 1 3/8" 2,3 1 3/8" 2,3 1 3/8" 2,3 1 3/8" 2,3 1 3/8" 2,3 1 3/8" 3,4 1 3/8" 3,4 1 3/8" 3,4 1 3/8" 3,4 1 3/8" 3,4 1 3/8" 3,4 1 5/8"

Tamao Tamao de la de la lnea de lnea de descarga asp.

/8" 7 /8" /8" 1 1 /8" /8" 1 1 /8" /8" 1 1 /8" 1 /8" 1 1 /8" 1 /8" 1 1 /8" 1 /8" 1 1 /8" 1 /8" 1 1 /8"1 1 1 1 7 7 7

7

50% 50% 50% 50% 50% 50% 50% 50% 50% 33% + 66% 33% + 66% 33% + 66% 33% + 66% 33% + 66% 33% + 66% 33% + 66% 33% + 66% 33% + 66% 33% + 66% 33% + 66% 33% + 66%

705 RA 001 VLC NRV 22S 22 100 705 RA 001 VLC NRV 22S 22 100 705 RA 001 VLC NRV 22S 22 100 705 RA 001 VLC NRV 22S 22 100 705 RA 001 VLC NRV 22S 22 100 705 RA 001 VLC NRV 22S 22 100 705 RA 001 VLC NRV 22S 22 100 705 RA 001 VLC NRV 22S 22 100 705 RA 001 VLC NRV 28S 28 100 705 RA 001 VLC NRV 28S 28 100 705 RA 001 VLC NRV 22S 22 100 705 RA 001 VLC NRV 28S 28 100

4,5 1 5/8" 4,5 1 5/8" 4,0 1 5/8"

3,6 1 5/8" 3,6 1 5/8" 1 1/8" 4,0 2 1/8" 1 1/8" 4,0 2 1/8" 1 3/8" 4,0 2 1/8" 1 3/8" 4,0 2 1/8" 1 3/8" 4,3 2 1/8" 1 3/8" 4,3 2 1/8" 1 3/8"

4,3 2 1/8" 1 3/8" 705 RA 001 VLC NRV 22S 22 1002 200 7,4 2 1/8" 1 3/8" 705 RA 001 VLC NRV 28S 28 1002 200 7,4 2 1/8" 1 3/8" 705 RA 001 VLC NRV 28S 28 1002 200 7,4 2 1/8" 1 3/8"705 RA 001 VLC NRV 28S 28 705 RA 001 VLC NRV 35S 42 705 RA 001 VLC NRV 35S 42 705 RA 001 VLC NRV 28S 28 705 RA 001 VLC NRV 35S 42 705 RA 001 VLC NRV 35S 42

-

200 7,7 2 5/8" 200 7,7 2 5/8" 200 7,7 2 5/8" 200 7,7 3 1/8" 200 7,7 3 1/8" 200 7,7 3 1/8"

1 /8" 5 1 /8" 1 /8" 5 1 /8" 1 /8" 5 1 /8"5 5

5

para compresores TWIN y funcionamiento en paralelo emplear vlvulas con muelle reforzado (tipo NRVH) disponible adicionalmente, mnimo 200 WD6.3.2/0203/S 14

11

Conexiones del compresor Discus

Conexiones del Compresor DiscusD2D_3D2DC3 - 500 D2DD3 - 500 D2DL3 - 400 D2DL3 - 750 D2DB3 - 500 D2DB3 - 750

Z.9.45.00

11

SL DL 1 2 3 4 5 6

Tamao lnea aspiracin (soldar) Tamao lnea descarga (soldar) 1 Conexin de baja presin /8 " 1 Conexin alta presin /8 " 1 /4 " Carga de aceite 1 /4 " Conexin presostato de aceite A P 1 Conexin presostato de aceite BP /4 " Obs medida presion salida de bomba 7 /16 "

- 27 NPTF - 27 NPTF - 18 NPTF 6 mm - 18 NPTF - UNF Obs

7 8 9 10 11 12 13 14

Filtro de aceite incorporado X 3 V aina (resistencia de crter) /8 " 1 Conexin de alta presin /8 " 1 Tapn magntico /8 " A nclajes Conexin del sensor/SENTRONIC X 3 Conexin de baja presin /4 " 1 Conexin de baja presin /8 " -

18 27 27 14

NPSL NPTF NPTF mm

14 NPTF 27 NPTF

D3D_4 / 5D3DA4 D3DA4 D3DC4 D3DC4 D3DS4 D3DS4 500 750 750 1000 1000 1500

Z.9.45.00

11

SL Tamao lnea aspiracin (soldar) DL Tamao lnea descarga (soldar) 1 1 Conexin de baja presin /8 " 1 2 Conexin alta presin /8 " 1 3 Carga de aceite /4 " 1 4 Conexin presostato de aceite A P /4 " 1 5 Conexin presostato de aceite BP /4 " 6 Obs medida presion salida de bomba 7 /16 " D6.3.2/0203/S

- 27 NPTF - 27 NPTF - 18 NPTF 6 mm - 18 NPTF - UNF Obs15

7 8 9 10 11 12 13 14

X Filtro de aceite incorporado 3 V aina (resistencia de crter) /8 " 1 Conexin de alta presin /8 " 1 Tapn magntico /8 " A nclajes Conexin del sensor/SENTRONIC X 1 Conexin de baja presin /2 " 1 Conexin de baja presin /8 " -

18 27 27 14

NPSL NPTF NPTF mm

14 NPTF 27 NPTF

.

D4D_3 / 4D4DA3 - 1000 D4DF3 - 1000 1) D4DA3 - 2000 D4DH3 - 1500 D4DL3 - 1500 1) D4DH3 - 2500 D4DJ3 - 2000 D4DT3 - 2200 1) D4DJ3 - 3000

Z.9.45.00

11

SL DL 1 2 3 4 5 6

Tamao lnea aspiracin (soldar) Tamao lnea descarga (soldar) Conexin de baja presin Conexin de alta presin Carga de aceite Conexin presostato de aceite A P Conexin presostato de aceite BP Obs de presion salida de bomba

" 1/ " 8 1/ " 4 1/ " 4 1/ " 4 7/ " 168

1/

27 27 18 6 - 18 - UNF

-

NPTF NPTF NPTF mm NPTF Obs

7 8 9 10 11 12 13 14

Filtro de aceite incorporado V aina (resistencia de crter) Conexin de alta presin Tapn magntico A nclajes Conexin del sensor/SENTRONIC Conexin de baja presin Conexin de alta presin

X1/ 1/

- 14 " - 27 1" - 16 18 X 3 / " - 18 8 1 / " - 27 88

2"

NPSL NPTF UN mm NPTF NPTF

D6D_3 / 4D6DH3 - 2000 D6DL3 - 2700 1) D6DH3 - 3500

Z.9.45.00

11SL DL 1 2 3 4 5 61)

Tamao lnea aspiracin (soldar) Tamao lnea descarga (soldar) Conexin de baja presin Conexin de alta presin Carga de aceite Conexin presostato de aceite A P Conexin presostato de aceite BP Obs de presion salida de bomba

" 1/ " 8 1/ " 4 1/ " 4 1/ " 4 7/ " 168

1/

27 27 18 6 - 18 - UNF

-

NPTF NPTF NPTF mm NPTF Obs

7 8 9 10 11 12 13 14

Filtro de aceite incorporado V aina (resistencia de crter) Conexin de alta presin Tapn magntico A nclajes Conexin del sensor/SENTRONIC Conexin de baja presin Conexin de alta presin

X1/ 1/

" - 14 NPSL " - 27 NPTF 1" - 16 UN 18 mm X 3 / " - 18 NPTF 8 1 / " - 27 NPTF 82 8

ilustracin sin v entilador

D6.3.2/0203/S

16

.

D6D_3/4D6DT3-3000 D6DJ3-3000 D6DJ3-4000

Z.9.45.00

11

SL DL 1 2 3 4 5 6 7

Tamao lnea aspiracin (soldar) Tamao lnea descarga (soldar) 1 Conexin de baja presin /8 " 1 Conexin de alta presin /8 " 1 /4 " Carga de aceite 1 /4 " Conexin presostato de aceite A P 1 /4 " Conexin presostato de aceite BP Obs medida presion salida de bomba 7 /16 " Filtro de aceite incorporado X

- 27 NPTF - 27 NPTF - 18 NPTF 6 mm - 18 NPTF - UNF Obs

8A 8B 9 10 11 12 13 14

1 Tapn resistencia de crter /2 " - 14 NPTF 1 Orif icio resistencia de crter /2 " 1 Conexin de alta presin /8 " - 27 NPTF Tapn magntico 1" - 16 UN 18 mm A nclajes Conexin del sensor/SENTRONIC X 3 Conexin de baja presin /8 " - 18 NPTF 1 Conexin de alta presin /8 " - 27 NPTF

D8D_1D8DL1-3700 D8DH1-5000 D8DT1-4500 D8DJ1-6000

Z.9.45.00

11

SL Tamao lnea aspiracin (soldar) DL Tamao lnea descarga (soldar) 1 1 Conexin de baja presin /8 " 1 2 Conexin de alta presin /8 " 1 3 Carga de aceite /4 " 1 4 Conexin presostato de aceite A P /4 " 1 5 Conexin presostato de aceite BP /4 " 6 Obs medida presion salida de bomba 7 /16 " 7 Filtro de aceite incorporado X D6.3.2/0203/S

- 27 NPTF - 27 NPTF - 18 NPTF 6 mm - 18 NPTF - UNF Obs17

8A 8B 9 10 11 12

1 Tapn resistencia de crter /2 " - 14 1 Orif icio resistencia de crter /2 " 1 Conexin de alta presin /8 " - 27 Tapn magntico 1" - 16 A nclajes 18 Conexin del sensor/SENTRONIC X

NPTF NPTF UN mm

12

Pares de Apriete (Nm)

Pares de Apriete (Nm)V.de servicio de aspiracin V.de servicio de aspiracin V.de servicio de aspiracin V.de servicio de descarga V.de servicio de descarga V.de servicio de descarga Tapn 1, 2, 9, 14 Tapn 3, 5 Tapn 3, 5 Tapn 8 (resistencia crter) Tapn 13 Tapn 13 Tapn 13 Visor de aceite Visor de aceite Brida ciega visor de aceite Brida ciega filtro de aceite Bomba de aceite Tapn magntico Tapn magntico Culata Culata Tapa inferior del crter Tapa inferior del crter Anclaje Anclaje Anclaje Tapa posterior del esttor Tapa posterior del esttor Tapa posterior del esttor Tapa posterior del esttor Tapa contrapalier Tapa contrapalier Terminal de cable Terminal de cableD6.3.2/0203/S

mm

2D / 3D 4D / 6D 4D - 8D 2D / 3D 3D 4D - 8D 2D - 8D 2D / 3D 4D - 8D 2D / 3D 2D 3D 4D / 6D 2D / 3D 4D - 8D 2D / 3D 2D / 3D 2D - 8D 2D / 3D 4D - 8D 2D 3D - 8D 2D 3D - 8D 2D 3D 4D - 8D 2D 3D 4D - 6D 8D 2D 3D - 8D 2D - 8D 2D - 8D5

1 1 5

/2" - 13 /2" - 13

UNC UNC UNC UNC UNC UNC NPTF NPTF NPTF NPTF NPTF NPTF NPTF UNC UNC UNC UNC UNC NPTF UNC UNC UNC UNC UNC UNC UNC UNC UNC UNC UNC UNC UNC UNC UNF UNF

63 - 76 72 - 81 122 - 149 29 - 30 63 - 76 72 - 81 22 - 25 45 - 50 27 - 34 55 - 60 60 - 70 45 - 55 55 - 60 7 - 8 4 - 5 14 - 17 27 - 30 35 - 39 22 - 25 136 - 203 55 - 60 58 - 69 50 - 54 58 - 69 50 - 54 58 - 69 40 - 45 50 - 54 58 - 69 72 - 81 122 - 149 50 - 54 58 - 69 3 - 4 5 - 6,5

19,0 19,0 23,8 12,7 19,0 19,0 12,7 17,5 17,5 22,0 26,6 27,0 27,0 11,1 11,1 11,1 12,7 12,7 12,7 25,4 14,2 14,2 14,2 14,2 14,2 14,2 14,2 14,2 14,2 19,0 19,0 14,2 14,2 9,0 11,0

/8" - 11 /16" - 18 1 /2" - 131 1

/2" - 13 /8" - 27 1 /4" - 181 3

/4" - 18 /8" - 18 3 /4" - 141 3

/2" - 14 /8" - 18 1 /4" - 20 /4" - 20 /4" - 20 5 /16" - 181 5 1

/16" 1 /8" 1" 3 /8" 3 /8" 3 3

18 27 16 16 16

/8" - 16 /8" - 16 3 /8" - 163 3

/8" - 16 /8" - 16 3 /8" - 163 1

/8" - 16 /2" - 13 1 /2" - 133 3

/8" /8" 10 1 /4" 18

16 16 32 28

13

Instalacin del Ventilador Ventilador adicional tipo 75 Z (D2 D8)

A

1: Tuerca autoblocante (1,2 - 2 Nm) 2: Arandela 3: Soporte

4: Tuerca (40 - 48 Nm) 5: Arandela elstica 6: Arandela

7: Vastago 8: Tornillos para ventilador 9: Caja de conexiones (Mot.Monofasicos)

D2D

D3D

D3D1)

1) con control de capacidad

D4D

D6D1)

D8D

D6.3.2/0203/S

19

14 Arranque Descargado Cuando se arranque de forma directa un compresor, conectando el motor de ste a la red a travs de un nico contactor, la intensidad durante dicho arranque resultar ser varias veces superior a su intensidad nominal a regimen (sin tener en consideracin los fenmenos transitorios). En el caso de motores de gran potencia dicha corriente de arranque puede llegar a ser incluso tan grande que ello provoque distorsiones en el voltaje de la lnea elctrica de la instalacin. En aquellos compresores en los que deba limitarse la intensidad durante el arranque se emplearn sistemas que disminuyan la carga y que garanticen el mismo incluso cuando el voltaje sea de un 85 % del valor que figura en la placa de caractersticas. 14.1 Compresores D2D y D3D El sistema de arranque descargado consiste bsicamente en la instalacin de un bypass en el compresor que conecta el lado de descarga y el lado de aspiracin en el mismo. Para ello se emplear una vlvula solenoide y un conjunto de bridas, adaptadores y tuberas. Cuando se para el compresor la vlvula solenoide abre el citado bypass y mantiene el mismo abierto durante toda la fase de arranque. De esta manera, durante la citada fase, el gas refrigerante es cortocircuitado en el compresor sin que se produzca un incremento significativo de la presin y la carga del motor es disminuida. Una vez finalizado el procedimiento de arranque, por ejemplo cuando tenga lugar: - la conexin del segundo devanado de un motor part-winding o - la transicin del contactor de configuracin en estrella al de triangulo o - el cortocircuitado de las resistencias de arranque la vlvula solenoide cerrar la lnea de bypass. Se debe instalar una vlvula de retencin en la lnea de descarga del compresor, tal y como se muestra en la figura adjunta, para evitar que gas de la lnea de alta de la instalacin retroceda al lado de baja a travs del bypass de arranque. Se encuentra disponible un kit para su montaje posterior en la instalacin que consiste de las siguientes accesorios: 1 x conjunto de tubo y cuerpo de vlvula (1) 1 x accesorio Rotalock (2) 1 x junta Rotalock (3) 1 x junta - brida a culata (4) 1 x junta - brida a vlvula servicio (4) 1 x bobina de vlvula solenoide (5) 1 x vlvula de retencin 2 x tornillos 1/2" 13 UNC X 2-3/4" 4 5C

2 3Z.2.01.00

1Z.9.24.00

A

B

D

A Vlvula de servicio C Vlvula de retencin

B Anaconda D Al condensador

Montaje En primer lugar, desenrosque el tapn (13) y coloque el manguito Rotalock. A continuacin, desmonte la vlvula de servicio (DL) de la culata y reemplace su junta por otra nueva, asegurandose de limpiar cuidadosamente la superficie de esta ltima. Monte el conjunto de vlvula y tubera usando las juntas y componentes suministrados en el kit de montaje. Por ltimo, instale la vlvula de retencin en la lnea de descarga, tal y como se muestra en el dibujo, y realice una prueba de estanqueidad.

D6.3.2/0203/S

20

D2D

DL

D3DDL

13

V.1.12.00

V.1.13.00

14.2 Compresores D4D D8D Cuando se solicite un compresor de este tipo con arranque descargado, ste se suministrar con una culata especial que lleva en su interior adaptado un dispositivo de control. La correspondiente vlvula solenoide que comanda el citado dispositivo y su bobina se entregan por separado y debern ser instaladas en el compresor previamente a la puesta en marcha del mismo. El arranque descargado se adapta en fbrica tal y como muestran las ilustraciones de la p. 21. Para la vlvula solenoide se encuentran disponibles bobinas en diferentes voltajes: ( 10% CC, +10% - 15% CA). Voltage 50 Hz 60 Hz DC 220V X X 110V X X 24V X X X Tambin se encuentra disponible un kit para montaje posterior en la instalacin que consiste de: 1x culata para arranque descargadoU 1x plato de vlvulas y kit de juntas 1x vlvula solenoide (No 705 RA 001) 2x tornillos de montaje El citado kit no contiene la junta entre el plato de vlvulas y el bloque del compresor que deber pedirse por separado. El grosor de la junta se encuentra marcado en la misma. Montaje En principio, el arranque descargado se puede instalar en cualquier culata, aunque las opciones disponibles se encuentran ms limitadas cuando el compresor incorpora control de capacidad. El control de capacidad se debe nicamente instalar en las culatas especificas para ello. Elimine la placa adherida a la culata (brida ciega) y adapte la vlvula solenoide y su junta. Seguidamente, instale la vlvula de retencin en la lnea de descarga para evitar que gas desde el lado de alta presin del sistema pase al de baja a travs del bypass interior de la culata de arranque descargado. 14.3 Vlvula de Retencin D2D D8D Las vlvulas de retencin se deben seleccionar acorde a los valores de la tabla adjunta y instalar tal y como se muestra en la ilustracin. La seleccin realizada de esta manera permitir que la vlvula no ratee como consecuencia de la pulsacin del gas a lo largo de un amplio rango de aplicacin.Si se produjesen ruidos durante el funcionamiento tanto a carga parcial como a plena carga, ser necesario redimensionar la vlvula y adaptar la misma a las condiciones de trabajo existentes.

D6.3.2/0203/S

21

Posicin de Montaje de la Vlvula de Retencin

Compresor

V. Retencin

Compresor

1)

V. Retencin 2 X NRVH 22S 2 X NRVH 22S 2 X NRVH 28S 2 X NRVH 22S 2 X NRVH 28S 2 X NRVH 22S 2 X NRVH 28S 2 X NRVH 28S 2 X NRVH 28S 2 X NRVH 35S 2 X NRVH 35S 22 22 28 22 28 22 28 28 28 22 28

NRV 22S 22 D2D NRV 22S 22 D22D D3DA -500 / 50X NRV 22S 22 D33DA - 1000 / 100X D3D NRV 28S 28 D33D D4D NRV 22S 22 D44D D4DJ NRV 28S 28 D44DJ D6DL/ T NRV 22S 22 D66DL/ T D6DH/ J NRV 28S 28 D66DH D8DL NRV 28S 28 D88DL D8DT NRV 28S 28 D88DT D8DH NRV 35S 42 D88DH D8DJ NRV 35S 42 D88DJ 1) Tambin para funcionamiento de compresores en paralelo

D4D_3 / 4

U

U para arranque descargado start

!

D6D_ 3 / 4

D8D_ 1

D6.3.2/0203/S

22

D2D

D3D

D4D*, D6D*, D8D*

A4 3 1 2 6

B

5A: Funcionamiento estndar B: en arranque descargado 1: culata especial 2: Pistn de control 3: vlvula 4: bobina solenoide 5: Lado baja presin en la culata 6: Lado alta presin en la culata

D6.3.2/0203/S

23

15

Control de Capacidad

Todos los compresores Discus pueden ser suministrados con control de capacidad. Siempre deber de considerarse que cuando el compresor trabaja con control de capacidad su rango de aplicacin puede variar. Para evitar daos durante el transporte las vlvulas solenoide se entregan con el compresor por separado adaptando en su lugar una brida ciega en la culata correspondiente que incorpora el control. Previamente a su montaje, se deber eliminar la citada brida y la junta que se suministra y a continuacin adaptar la vlvula solenoide y una nueva junta aplicando un par de apriete de 58-69 Nm.Al igual que en el caso anterior, se encuentra disponible un kit para montaje posterior en la instalacin. Este kit no incluye la junta comprendida entre el plato de vlvulas y el bloque del compresor, que deber de ser pedida por separado. El espesor de la junta se encuentra serigrafiado en la misma. Cuando se realice el pedido, indiquen el refrigerante que ser utilizado. Para consultar sobre los kits de conversin disponibles , vea las listas de repuestos ; los kits contienen las instrucciones de montaje y una completa relacin de todos sus componentes. 15.1 Moduload para Compresores D3D El Moduload es un control de capacidad basado en el principio de la variacin del volumen del espacio muerto en la cabeza de los pistones del compresor. Este tipo de control de capacidad reduce tanto la potencia frigorfica como la potencia absorbida practicamente en la misma proporcin, lo que asegura unas prestaciones optimas incluso a carga parcial. La vlvula solenoide puede ser activada por un termostato, un presostato o un conmutador manual. Cuando activemos la vlvula solenoide se habilitar una conexin con la zona de aspiracin del compresor que va a determinar que el rea superior de los tres pistones de control quede sometida a la presin all existente (presin de aspiracin). Esta accin favorecer que los pistones, que hasta ahora se encontraban a merced de la presin de descarga, se desplacen por el empuje de un muelle interno poniendo al descubierto un espacio muerto adicional. Existen dos versiones diferentes de Moduload: 1. Adaptable para R22 y los aceites lubricantes aprobados; 2. Adaptable para refrigerantes HFC R134a, R407C y R404A / R 507 y los consiguientes lubricantes aprobados por COPELAND. El MODULOAD no debera ser instalado en compresores con DEMAND COOLING.

A7 1

B

2

3

4 5 6A: Funcionamiento a plena carga B: Funcionamiento a carga parcial 1: Vlvula de controlD6.3.2/0203/S

2: Pistn de control 3: Culata 4: Plato de vlvulas24

5: Bloque compresor 6: Pistn 7: Bobina solenoide

15.2

Seleccin del Control de CapacidadControl de Capacidad Moduload

D3DDiagrama 1 2 3 Compresor con MODULOAD D3DA*-50X L D3DC*-75X L D3DS*-100X L D3DA*-750H D3DC*-1000H D3DS*-1500H

Seleccin del Control de Capacidad Refrigerante

Compresor con MODULOAD D3DA*-50XH D3DC*-75XH D3DS*-100XH D3DA*-75XH D3DC*-100XH D3DS*-150XH D3DA*-75XH D3DC*-100XH D3DS*-150XH

Refrigerante R 134a R 134a R 404A

Rango HM HH HM

Rango LXZ HM

Diagrama 4 5

R404A R 22

DISCUS90

Voltajes de las bobinas de las vlvulas solenoide: 24 V CC. 24 V / 1~ / 50 Hz 120 V / 1~ / 50 / 60 Hz 208-240 V / 1~ / 50 / 60 Hz Indice de proteccin: IP 55 (evaluacin segn IEC 34) Los diagramas siguientes muestran el rango de aplicacin del compresor cuando ste trabaja con control de capacidad. Asimismo se presentan tanto la capacidad frigorfica como la potencia absorbida que an ste o puede suministrar a 25 C de temperatura del gas de aspiracin. Capacidad frigorfica (carga parcial) = Capacidad frigorfica (a plena carga) x factor Potencia absorbida (carga parcial) = Potencia absorbida (a plena carga) x factor

D6.3.2/0203/S

25

15.3

Control de Capacidad Moduload

D3D Diagrama 1

Factores de carga parcial 134a HM

DISCUSCapacidad Frigorfica %

Potencia absorbida %

Capacidad Frigorfica %

Temperatura Evaporacin C

Ejemplo

D6.3.2/0203/S

26

Condensacin C

15.4

Control de Capacidad Moduload

D3D Diagrama 2

Factores de carga parcial R134a HH

DISCUSCapacidad Frigorfica %

Potencia absorbida % Power input %

Capacidad Frigorfica %

Temperatura Temperature EvaporatingEvaporacin C C

Example Ejemplo

D6.3.2/0203/S

27

Condensacin C

15.5

Control de Capacidad Moduload

D3D Diagrama 3

Factores de carga parcial R404A HM

DISCUSCapacidad Frigorfica %

Power input % Potencia absorbida %

Capacidad Frigorfica %

Temperatura Evaporacin C Evaporating Temperature C

D16.0/0993

Example Ejemplo

D6.3.2/0203/S

28

Condensacin C

15.6

Control de Capacidad Moduload

D3D Diagrama 4

Factores de carga parcial R404A LXZ

DISCUSCapacidad Frigorfica %

Potencia absorbida % Power input

Capacidad Frigorfica %

Evaporating Temperature Temperatura Evaporacin C

C

D17.0/0993

Example Ejemplo

D6.3.2/0203/S

29

Condensacin C

15.7

Control de Capacidad Moduload

D3D Diagrama 5

Factores de carga parcial R22 HM

DISCUSCapacidad Frigorfica %

Power input % Potencia absorbida %

Capacidad Frigorfica %

Evaporating TemperatureC Temperatura Evaporacin CExample Ejemplo

D37.0/099 3

D6.3.2/0203/S

30

Condensacin C

16

Control de Capacidad D4D D8D

Compresores D4D, D6D y D8D En los compresores D4D, D6D, y D8D el control de capacidad se basa en el principio de bloqueo de la entrada del gas de aspiracin a dos o ms cilindros. Para ello se necesita el empleo de una culata especial, una vlvula de control y un plato de vlvulas especialmente preparado. Se puede solicitar que todos estos componentes se suministren de fbrica ya instalados en el compresor o en forma de kit para su montaje posterior. Funcionamiento normal (a plena carga) Cuando se deja de alimentar la bobina de la vlvula solenoide el rea superior del pistn de control se encuentra bajo la influencia de la presin de aspiracin, lo que va a favorecer que dicho pistn pueda elevarse gracias al empuje de su muelle interior. En esta situacin, el gas entra en todos los cilindros del compresor y por lo tanto ste funcionar a plena carga. Funcionamiento con control de capacidad (a carga parcial) Cuando se activa la bobina de la vlvula solenoide el pistn de control deja de estar sometido a la presin de aspiracin del compresor y pasa a ser comandado por la presin de descarga del mismo. Bajo el efecto de dicha presin el citado pistn se desplaza, bloqueando el paso de refrigerante a los cilindros y obligando por tanto a que el compresor funcione a carga parcial. Voltajes de la bobina de la vlvula solenoide: 24 V CC. 24 V / 1~ / 50 Hz 120 V / 1~ / 50 / 60 Hz 208-240 V / 1~ / 50 / 60 Hz Indice de proteccin: IP 55 (evaluacin acorde a IEC 34)

A1

B

2

3 4

A = Funcionamiento a plena carga B = Funcionamiento a carga parcial 1 = Vlvula solenoide

2 = culata 3 = Pistn de control 4 = Plato de vlvulas

D6.3.2/0203/S

31

16.1

Juntas en las culatas de control de capacidad de compresores semihermticos de 4-6-8 cilindros Todas las culatas con control de capacidad de los compresores semihermticos de 4,6,y 8 cilindros se entregan con una brida ciega y una junta que inactiva el citado control. Esto asegura que el compresor funcione a plena capacidad si por alguna razn en el ltimo momento se decide no instalar la vlvula solenoide de control. Para activar el control de capacidad, se deben eliminar la brida ciega y la junta inactiva y reemplazar ambas por la vlvula solenoide y la correspondiente junta activa que se suministra con el kit de conversin Esta variacin en la fabricacin se hizo efectiva en todos los compresores fabricados en nuestra planta en Welkenraedt a partir del 17 de Agosto de 1999. El kit de conversion kit incluye; 1x 1x 1x 2x culata para control de capacidad C plato de vlvulas y un kit de juntas Vlvula solenoide (No 703 RB 001) Tornillos de montaje

El control de capacidad se debe adaptar en las siguientes posiciones: D4D D6D D6D D8D D8D 1 etapa 2 etapa 1 etapa 2 etapa 50% 33% 66% 25% 50% Lado de la caja de conexiones Lado de la caja de conexiones culata central culata inferior en el lado de la caja de conexiones culata inferior en el lado de la vlvula de descarga

D4D 3 / 4

50%

Cactivo inactivo

D6D 3 / 466%

C para control de capacidad

D8D 1

33%

Opcional 50% 50% 25%

16.2D6.3.2/0203/S 32

Seleccin del Control de Capacidad, R134a

Control de Capacidad

D4D - D8DSeleccin del Control de Capacidad Etapas de Regulacin 0 1 50% 50% 50% 50% 50% 50% 66% 66% 66% 66% 75% 75% 2

Tabla de Seleccin

R 134 aN Diagrama

Compresor

N de Cilindros con Control Capacidad

D4DA-100X D4DH-150X D4DA-200X D4DJ-200X D4DH-250X D4DJ-300X D6DH-200X D6DJ-300X D6DH-350X D6DJ-400X D8DH-500X D8DJ-600X

2 2 2 2 2 2 2/4 2/4 2/4 2/4 2/4 2/4

100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%

33% 33% 33% 33% 50% 50%

Cap.de Refrigeracin Remanente/P.Absorbida (Valores medios) % Rango de Aplicacin HH H M L HH H M L 51 52 53 59 51 52 53 59 51 53 51 52 53 59 51 53 51 53 67/34 68/34 68/36 70/41 67/34 68/34 68/36 70/41 67/34 68/36 67/34 68/36 75/51 75/51 75/52 77/53 77/53 78/59 75/51 75/51 75/52 77/53 77/53 78/59

8 8 9 8 9 9 8 8 9 9 8(HM) /10(HH) 8(HM) /10(HH)

Para consultar limites de aplicacin, ver hoja de datos o diagrama de trabajo HH = Bomba de calor H = Alta M = Media L = Baja Temperatura

D6.3.2/0203/S

33

16.3

Control de Capacidad

D4D D8D

Rango de Aplicacin R134a

Diagrama 8 Temperatura gas aspiracin 25C

Condensacin C

Diagrama 9 Recalentamiento 20 K

Evaporacin

Condensacin C

Lmite de aplicacin. Ver hoja de datos

Diagrama 10 Recalentamiento 20 K

Evaporacin

Condensacin C

EvaporacinD6.3.2/0203/S 34

16.4

Seleccin del Control de Capacidad, R22

Control de Capacidad

D4D - D8DSeleccin del Control de Capacidad Etapas de Regulacin 0 1 50% 50% 50% 66% 66% 75% 75% 2

Tabla de Seleccin

R 22N Diagrama

Compresor

N de Cilindros con Control Capacidad

Cap.de Refrigeracin Remanente/P.absorbida (valores medios) %

D4DA-2000 D4DH-2500 D4DJ-3000 D6DH-3500 D6DJ-4000 D8DH-5000 D8DJ-6000

2 2 2 2/4 2/4 2/4 2/4

100% 100% 100% 100% 100% 100% 100%

33% 33% 50% 50%

Rango de Aplicacin H H 51 53 51 53 51 53 67/34 68/34 67/34 68/34 76/52 80/58 76/52 79/57

11

12

Para consultar lmites de aplicacin, ver hoja de datos o diagrama de trabajo H = Alta

D6.3.2/0203/S

35

16.5

Control de Capacidad

D4D D8D

Rango de Aplicacin R22

Diagrama 11 Temperatura Gas Aspiracin 25C

Condensacin C

Evaporacin

Diagrama 12 Temperatura Gas Aspiracin 25C

Condensacin C

Evaporacin

D6.3.2/0203/S

36

16.6

Seleccin del Control de Capacidad, R404A

Control de Capacidad

D4D - D8DSeleccin del Control de Capacidad Etapas de Regulacin 0 1 50% 50% 50% 50% 50% 50% 66% 66% 66% 66% 75% 75% 75% 75% 2

Tabla de Seleccin

R 404AN Diagrama

Compresor

N de Cilindros con Control Capacidad

D4DF-100X D4DL-150X D4DA-200X D4DT-220X D4DH-250X D4DJ-300X D6DL-270X D6DT-300X D6DH-350X D6DJ-400X D8DL-370X D8DT-450X D8DH-500X D8DJ-600X

2 2 2 2 2 2 2 2 2/4 2/4 2 2 2/4 2/4

100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%

33% 33%

50% 50%

Cap.de Refrigeracin Remanente/P.Absorbida (valores medios) % Rango de Aplicacin HH H M L HH H M L 52 59 52 59 51 52 53 59 52 59 51 52 53 59 51 52 53 59 68 70 68 70 67/34 68/34 68/36 70/41 67/34 68/34 68/36 70/41 77 78 77 78 76/52 76/52 79/56 80/58 76/53 76/53 79/56 80/58

13 13 15 13 15 15 13 13 16 16 14 14 17 17

Para consultar lmites de aplicacin, ver hoja de datos y diagrama de trabajo HH = Bomba de Calor H = Alta M = Media L = Baja Temperatura

D6.3.2/0203/S

37

16.7

Control de Capacidad

D4D D8D

Rango de Aplicacin R404A

Diagrama 13 Temperatura Gas Aspiracin 25C Condensacin C

Lmite de aplicacin. Ver hoja de datosOperacin Operacin slo slo con con ventilador ventilador adicional adicional

Evaporacin Diagrama 14 Temperatura Gas Aspiracin 25C

Operacin slo con ventilador adicionalCondensacin C

Evaporacin

Condensacin C

Diagrama 15 Temperatura Gas Aspiracin 25C

*) Operacin slo con ventilador adicional

EvaporacinD6.3.2/0203/S 38

Control de Capacidad

D4D D8D

Rango de Aplicacin R404A

Diagrama 16 Temperatura Gas Aspiracin 25C. Reduccin al 33 % con un ventilador adicional estndar no es posible debido a la falta de espacio *) Operacin slo con ventilador adicional

Condensacin C

Evaporacin

Diagrama 17 Temperatura Gas Aspiracin 25C

Condensacin C

Evaporacin

D6.3.2/0203/S

39

16.8

Seleccin del Control de Capacidad, R407C

Control de Capacidad

D4D - D8DSeleccin del Control de Capacidad Etapas de Regulacin de Capacidad 0 1 50% 50% 50% 66% 66% 75% 75% 2

Tabla de Seleccin

R407C(pto medio) NDiagrama

Compresor

N de Cilindros con Control de Capacidad

Cap. Refrigeracin Remanente/P.Absorbida (valores medios) %

D4DA-200X D4DH-250X D4DJ-300X D6DH-350X D6DJ-400X D8DH-500X D8DJ-600X

2 2 2 2/4 2/4 2/4 2/4

100% 100% 100% 100% 100% 100% 100%

33% 33% 50% 50%

Rango de Aplicacin H H 51 53 51 53 51 53 67/34 68/34 67/34 68/34 76/52 80/58 76/53 79/57

18

19

Para consultar lmites de aplicacin, ver hoja de datos y diagrama de trabajo H=Alta

D6.3.2/0203/S

40

16.9

Control de Capacidad

D4D D8D

Rango de Aplicacin R407C (pto medio)

Diagrama 18 D4D D6D Temperatura Gas Aspiracin 25 C65

[ C]

60 55 50100% 66% 50% 33%

Condensacin

O

45 40 35 30 25 20 15 -30 -25 -20 -15 -10 -5

0

5

10

15

Evaporacin Diagrama 19 - D8D Temperatura Gas Aspiracin 25 C65

[ C]

O

[ C]

60 55 50 45

O

100% 75% 50%

Condensacin

40 35 30 25 20 15 -30 -25 -20 -15 -10 -5 0 5 10 15

Evaporacin

[ C]

O

D6.3.2/0203/S

41

17

Platos de Vlvulas Discus D4D - D6D

Para obtener un rendimiento optimo, los platos de vlvulas de los compresores Discus difieren dependiendo del rango de aplicacin (Media o baja temperatura) y de las caractersticas de los mismos. Los platos de vlvulas empleados en compresores con control de capacidad y arranque descargado incorporan un puerto adicional X .

Alta & Media 2 1

Baja Temperatura

18

Compresores TWIN D44D - D66D

En las anteriores versiones de este tipo de compresores el enfriamiento del motor elctrico se consegua haciendo pasar el gas refrigerante a travs de una serie de agujeros distribuidos uniformemente en el interior del rotor(2). Actualmente, los compresores D4D- y D6D se fabrican con una serie de pasos internos en el bloque (1) a travs de las cuales fluye el citado gas alrededor del estator. De esta forma se consigue enfriar optimamente el motor y al mismo tiempo incrementar la eficiencia del compresor al reducir considerablemente las perdidas que el citado paso conlleva.

2

1

Vista de un compresor despus de extraer la cmara de aspiracin Los compresores TWIN por lo tanto necesitan utilizar nuevas cmaras de aspiracin provistas de unas hendiduras especiales capaces de adaptarse a la citada actual configuracin de los bloques de los compresores D4 y D6 Cuando se sustituya un compresor en una configuracin TWIN deber de tenerse en cuenta el nmero de serie del compresor involucrado, al objeto de considerar o no la necesidad de reemplazar igualmente la cmara de aspiracin comn por los detalles anteriormente citados.D6.3.2/0203/S 42

18.1 Nueva Cmara de Aspiracin El empleo de las nuevas cmaras de aspiracin con compresores fabricados con anterioridad a la fecha indicada en el apartado de validez de esta publicacin no supone ningn problema e incompatibilidad. La tabla siguiente ayudar a identificar la antigedad de las cmaras de aspiracin a travs de un nmero serigrafiado en su carcasa. Estos nmeros no deben ser utilizados como referencia o nmero de pedido.

Compresor TWIN D44DF D44DH D44DA D44DA D44DL D44DH D44DJ D44DJ D66D . 2000 3000 2000 4000 3000 5000 4000 6000 ....

Modelo Antiguo 019-0042-99

Modelo Nuevo 019-0050-99

019-0004-99

019-0049-99

19 Resistencia de Crter El aceite que se encuentra en el crter de un compresor puede absorber una cantidad mayor o menor de refrigerante dependiendo de la presin y temperatura existente en dicho crter. Se puede dar el caso de que esta cantidad de refrigerante absorbido sea tan grande, especialmente cuando el compresor se encuentra fuera de servicio, que ello incluso provoque variaciones significativas en el nivel de aceite que se aprecia en el visor. Si en estas condiciones se arrancase el compresor, con la consiguiente disminucin de la presin en el crter, se favorecera la formacin de una densa espuma en la mezcla refrigerante y aceite que inevitablemente deteriorara la capacidad lubricante de este ltimo. Esta espuma incluso podra ser arrastrada hacia el interior de los pistones provocando la aparicin de fenmenos de golpe de lquido y/o aumento de la cantidad de aceite arrastrada al circuito de refrigeracin. El riesgo de disolucin del refrigerante en el aceite aumenta si: a) El compresor se encuentra a una temperatura ms baja que el resto de componentes frigorficos del sistema. Cuando la instalacin no se encuentra operativa podra ocurrir que el gas refrigerante condensase en la zona ms fra del circuito por ejemplo,en el compresor b) No se ha instalado un presostato de control de parada por baja y por tanto el lado de baja presin est sometido a relativamente altas presiones durante dicha parada. El hecho de que el contenido de refrigerante en el aceite sea ms bajo a altas temperaturas y bajas presiones es la razn que justifica la instalacin de resistencias elctricas en el crter del compresor. La funcin de la resistencia de crter es la de mantener la temperatura del aceite durante la parada del compresor por encima de la del punto ms fro del sistema. Estas resistencias han sido dimensionadas al objeto de hacer imposible un sobrecalentamiento del aceite, siempre y cuando estas se utilicen correctamente durante su funcionamiento. Sin embargo, y a muy bajas temperaturas ambiente, podra ocurrir que la potencia aportada por ellas no fuera suficiente para evitar la absorcin de refrigerante, haciendo necesario en ese caso el empleo de otros sistemas alternativos de prevencin como por ejemplo la parada por baja. La resistencia de crter puede contribuir a prevenir los efectos de golpe de lquido como consecuencia del espumado del aceite durante el arranque del compresor. Sin embargo, los problemas por el mismo motivo relativos a la incorrecta instalacin de la lnea de aspiracin o por otras causas no pueden ser evitados por la citada resistencia. La resistencia se instalar en un alojamiento especial o en una vaina en el interior del crter del compresor al objeto de hacer posible su sustitucin sin necesidad de abrir el circuito frigorfico. El espacio entre la resistencia y la vaina debera ser rellenado con una pasta conductora para mejorar la transferencia de calor. En las paginas 14,15 y 16 Conexiones del compresor Discus se muestra la ubicacin exacta de su montaje.

D6.3.2/0203/S

43

Los compresores D2D y D3D se suministran con una resistencia de carter de 70 W, mientras que en los compresores D4D y D6D su potencia es de 100 W. Los modelos D6DJ, D6DT, y D8D disponen de un alojamiento especial separado en su carter para emplear una resistencia de 200 W. 19.1 Resistencia 70 W / 100 W y vaina.

Dimensiones Resist. Alimentacin Watt Voltaje A B C mm D mm 163 D2D, D3D 70 230 + 10 % 3/8" -18 NPTF 3/8" -18 NPSL 112 D4D, D6D 100 220 +20 / -10% 1/2" -14 NPTF 1/2" -14 NPSL 125 190 D4DJ*,D6DJ/T*,D8D 200 240 +10 / -15% 103 126 * con crter profundo Compresor19.2 Resistencia 200 Watt

E mm G mm H mm J mm 710 900 19 22 600 750 22 27 700 900 200 50

1

2

3 4

1 tapn magnetico 2 Soporte sujeccin

3 Resistencia 200 W 4 Crter profundo

D6.3.2/0203/S

44

20

Bomba de Aceite

Todos los compresores Discus llevan incorporado en su bomba de aceite el sensor del sistema de control elctronico de la presin de aceite OPS1 para facilitar la incorporacin posterior del mismo. Del mismo modo la bomba admite la posibilidad de utilizar el sistema SENTRONIC o conectar un presostato diferencial de aceite mecnico aprobado como por ejemplo ALCO FD 113 ZU (A22-156) ver pgina 52.

3

A1

B4

2 6

A

B

5 7

A posicin D4, D6, D8 B posicin D2, D3 1: Carcasa bomba de aceite 2: Rotor de la bomba de aceite 3: Conexin abocardar para el tubo capilar del presostato de aceite 7 4: /16" - UNF Vlvula Obs 5: Sensor OPS1 o conexin para el sensor electrnico del sistema SENTRONIC 6: Vlvula limitadora de presin de la bomba a 4,2 bar (no regulable) 7: Tornillos de fijacin ( 3 + 3 piezas)

D6.3.2/0203/S

45

20.1 Adaptador Dado que la nueva bomba de aceite se emplea en todos los compresores enfriados por el gas de aspiracin resulta necesario emplear un adaptador, que centre dicha bomba durante su montaje y adapte la misma a los diferentes dimetros de cigueal de los modelos de compresores existentes (ver Fig. "a"). El anillo adaptador se fija a la bomba de aceite en el lado de la leva de conexin de la misma al cigeal del compresor (ver Fig. "b"). Para fijar este anillo existe un resalte en el mismo (ver Fig "a" seccin A) que se adapta a una ranura especial en el cuerpo de la bomba de aceite (ver Fig. "b" seccin "B). Es necesario que la leva de la bomba y la hendidura del cigeal del compresor, que sirve como elemento de accionamiento de la misma, se encuentren perfectamente alineados (ver Fig. "b", seccin "C").Fig. "a" Fig. "b"

C

Compresor D2D & D3D D4D, D6D, D8D

Adaptador D = 40.4 mm D = 49.2 mm

Material de la junta Wolverine Wolverine

20.2 Junta de la bomba de aceite La junta de la bomba de aceite actual es valida para todas las bombas de los compresores Discus , sin embargo, la junta del anterior modelo de bomba de aceite concentrica utilizada en este tipo de compresores no se puede adaptar en las nuevas bombas.

D2D, D3D

D4D, D6D, D8D

D6.3.2/0203/S

46

21 Control de Presin Diferencial de Aceite OPS1 La principal funcin del sistema de control electrnico OPS1 es la de supervisar la presin diferencial de aceite en los compresores alternativos de refrigeracin y aire acondicionado. El OPS1 consiste de dos elementos, un sensor de presin y un interruptor de control electrnico, lo que hace del mismo un sistema simple y fcil de instalar. El sensor se suministra ya montado en los compresores y tan slo es necesario adaptar el interruptor de control a dicho sensor para hacer el sistema operativo. Igualmente, es un sistema ecolgico, ya que los riesgos de fuga de refrigerante se encuentran minimizados al no requerir de las conexiones de tubos capilares tpicas de los sistemas mecnicos tradicionales. El sensor de presin diferencial se enrosca directamente en la carcasa de la bomba de aceite del compresor, donde existen interiormente una serie de canales que conectarn los puertos de entrada y descarga de la misma con el citado sensor. El interruptor de control electrnico se puede instalar o sustituir en caso de avera sin necesidad de abrir el circuito de refrigeracin

Descripcin del funcionamiento: Para proceder a activar el control de presin diferencial OPS1 deber de alimentarse electricamente ste tal y como se describe en el esquema elctrico de la pag. 57 (a travs del contacto auxiliar del contactor del compresor K1). Dicho estado activo se pondr de manifiesto de forma inmediata si se enciende un LED de color rojo en el interrruptor de control. Este led ser igualmente una indicacin de que la actual presin diferencial en el compresor es insuficiente. Transcurrido un breve tiempo, y una vez la presin diferencial alcance el valor de consigna preestablecido en el controlador, el citado led se apagar. El contacto de salida siempre permanece cerrado si dicho valor de consigna se alcanza o sobrepasa, abriendo slo en el caso de que la presin diferencial de aceite fuera inferior al citado valor durante un tiempo superior a los 120 sg. El desbloqueo mecnico de este contacto y la reactivacin del control solo son posibles oprimiendo el botn de rearme incorporado en el interruptor electrnico. Los periodos de tiempo, inferiores al retardo, durante los cuales la presin de aceite es insuficiente son tambin reconocidos y registrados por el microprocesador del controlador, provocando la actuacin de ste si la suma de todos esos periodos sobrepasa el valor preestablecido de 120 segundos (integracin) ) Slo personal cualificado debe conectar la unidad. Todas las normativas vigentes relativas a la conexin elctrica y a los equipos de refrigeracin sern contempladas y por ningn motivo se debern sobrepasar los lmites de voltaje de alimentacin dados. El interruptor electrnico no necesita mantenimiento. Datos Tcnicos:Alimentacin Rango Temperatura ambiente Retardo Presin de arranque (fija) Presin de corte (fija) Caractersticas contacto Compatibilidad refrigerante Clase de proteccin (EN 60259) Rearme Cable de conexin PesoD6.3.2/0203/S

AC 50/60 Hz 230V +/ 10% 10VA -30..+60C 120 s 0,95 bar +/- 0,15 bar 0,63 bar +/- 0,15 bar AC 250 V, max. 2,5A, 720 VA ind. Si (Latn) IP54 manual 4xAWG20 (0,5 mm2), L=1m de diferente color ca. 200 g47

22

Nuevo sistema de seguridad de la presin de aceite SENTRONIC+

TM

Todos los compresores Discus estn provistos de una bomba de aceite compatible con el sistema de seguridad de presin de aceite - SENTRONIC. Este sistema, que puede ser solicitado opcionalmente, consta de los siguientes elementos: 1x 1x 1x 2x Mdulo (1) Sensor (2) Soporte de Montaje Tuercas autoblocantes 2x 2x 1x 1x Tornillos Arandelas glower Anillo trico (3) Junta (4)

sensor

22.1 Datos Tcnicos Presin de corte: 0.55 Presin de arranque: 0.90 Retardo: 120 Mxima Potencia de corte: 720 VA Mxima Temperatura ambiente: 66C Rearme manual Conexiones de alarma incorporadas

0.1 bar 0.1 bar 15 s 120/240 V

22.2 Operacin El funcionamiento del control se basa en la medida de la presin diferencial, entre la salida de la bomba y el crter, y la conversin de dicha medida en una seal electrnica. Si la presin neta de aceite (presin diferencial medida) de un compresor en funcionamiento cae a 0,55 0,1 bar, ste se detendr inmediatamente una vez concluya la temporizacin de 120 15 segundos establecida en el control. Por otro lado, aquellos perodos de tiempo, inferiores a la temporizacin, durante los cuales la presin neta de aceite se encuentre porD6.3.2/0203/S 48

debajo de 0,9 0,1 bar, sern igualmente registrados por el mdulo de control que actuar parando el compresor cuando la suma de dichos periodos totalice aproximadamente 2 minutos. El reloj interno del modulo se resetea cuando ste contabiliza un total de 4 minutos continuos de presin adecuada. En caso de interrupcin del suministro elctrico, el mdulo SENTRONIC mantiene la informacin almacenada durante 1 minuto. El empleo de un sistema de control apropiado de la presin diferencial de aceite es una condicin obligatoria para la aplicacin de la garanta. 22.3 Montaje El mdulo se fija mediante dos tornillos y dos arandelas glower al soporte de anclaje (par de apriete 2,5 Nm), el cual a su vez se fija a los esprragos de la tapa contrapalier utilizando las tuercas autoblocantes (par de apriete 25 Nm) suministradas en el kit. Con el compresor sin presin, extraer el tapn inferior de la bomba de aceite, el anillo trico y la junta y reemplazarlos por el sensor usando un anillo trico y una junta nuevos. Aplicar un par de 105 Nm. Finalmente, conectar el sensor al mdulo. 22.4 Conexin elctrica Ver el esquema de conexiones de la pgina 65. La alimentacin elctrica del modulo se realiza a travs de los terminales sealados por las etiquetas"240V" o "120V" y "2". El neutro debe conectarse siempre al terminal "2". El circuito de maniobra se conectar en serie a los terminales "L" y "M". El terminal "A" puede servir para activar una alarma externa. Tambin se encuentra disponible una conexin a tierra. La alimentacin interna para el funcionamiento del mdulo proviene de un transformador que est conectado a los terminales "2" y "120" o "240", segn el voltaje aplicado. 22.5 Prueba de funcionamiento El mdulo SENTRONIC puede probarse como se indica a continuacin: 1. Desconectar la alimentacin elctrica 2. Extraer la conexin del sensor. 3. Conectar la alimentacin. 4. Despus de 2 minutos 15 segundos (retardo de tiempo) el contacto entre "L" y "M" debera estar abierto y el contacto entre "L" y "A" cerrado (test de parada). 5. Mientras se mantiene desconectada la alimentacin, cortocircuitar las conexiones del sensor en el mdulo. Volver a activar el mdulo poniendo en funcionamiento ste empleando el botn de rearme. Ahora el mdulo no debera actuar sobre el contacto despus de que hubiera transcurrido el tiempo permitido. El sensor puede comprobarse con un ohmetro. Desconectar el cable y medir la resistencia del sensor en sus conexiones. El ohmetro debe indicar infinito cuando el compresor est parado y 0 ohms cuando est funcionando con suficiente presin de aceite. La presin de aceite puede comprobarse midiendo la presin diferencial entre la vlvula de obs de la bomba y el crter del compresor. Esta presin es aproximadamente la misma que la medida por el sensor SENTRONIC. El nuevo sistema Sentronic de Copeland se caracteriza por incluir nuevos LED de diagnostico para facilitar la evaluacin de la condiciones de la pres