Conventional Surface Wellheads

  • Upload
    kpklav

  • View
    266

  • Download
    4

Embed Size (px)

Citation preview

  • 8/10/2019 Conventional Surface Wellheads

    1/21

    Conventional Surface WellheadsFlexibility, compatibility and interchangeability for a wide range of surface applications.

    SURFACE SYSTEMS

  • 8/10/2019 Conventional Surface Wellheads

    2/21

    Conventional Wellhead Systems

    S and IC Wellhead Systems . . . . . . . . . . . . . . . 3

    Selecting a Wellhead System . . . . . . . . . . . 3

    Major Considerations for

    Casing Hanger Selection . . . . . . . . . . . . . . . 3

    S Wellhead System. . . . . . . . . . . . . . . . . . . . 4

    IC Wellhead System . . . . . . . . . . . . . . . . . . . 5

    Casing Head Housings . . . . . . . . . . . . . . . . . . . 6

    Casing Head Housing

    Bottom Connection Options . . . . . . . . . . . . 6

    Casing Head Housing Comparison . . . . . . . 7

    Casing Head Spools . . . . . . . . . . . . . . . . . . . . . 8

    Secondary Seals. . . . . . . . . . . . . . . . . . . . . . . . . 8

    Casing Head Spools Comparison . . . . . . . . 9

    Secondary Seals Comparison. . . . . . . . . . . . 9

    Casing Hangers . . . . . . . . . . . . . . . . . . . . . . . . 10

    Casing Hangers for S Casing Head

    Housings and Spools . . . . . . . . . . . . . . . . . 10

    SB Casing Hanger Comparison . . . . . . . . . 10

    Casing Hangers for IC-2 Casing Head

    Housings and Spools . . . . . . . . . . . . . . . . . 11

    IC Casing Hanger Comparison . . . . . . . . . . 11

    Tubing Spools and Hangers

    Selecting a Completion System . . . . . . . . . . . 12

    Tubing Spool, Tubing Hanger Compatibility . 13

    Major Considerations for

    Tubing Hanger Selection. . . . . . . . . . . . . . . . . 13

    Tubing Spool Comparison. . . . . . . . . . . . . . . . 13

    Single Completions . . . . . . . . . . . . . . . . . . . . . 14

    Tubing Spools for Single Completions . . . 14

    Tubing Hangers for Single Completions. . 14

    Comparison of Tubing Hangers

    for Single Completions . . . . . . . . . . . . . . . 15

    Dual and Critical Service Completions. . . . . . 16

    Tubing Spools for Dual Completions . . . . 16

    Tubing Hangers for Dual Completions . . . 16

    Comparison of Tubing Hangers

    for Dual Completions . . . . . . . . . . . . . . . . . 16

    Tubing SpoolsCritical Service Completions 17

    Tubing HangersCritical Service Completions 17

    Auxiliary Equipment

    Lock Screws, Test Ports and Injection Ports . 18

    Cameron Conventional

    Wellhead Systems

    FLEXIBLE. COMPATIBLE. INTERCHANGEABLE.

    For a wide range of surface applications. Using

    Cameron systems lets you reduce inventory require-

    ments, lower costs and use standard components.

    Camerons conventional wellheads and Christmas

    trees suit any casing and tubing programs for working

    pressures up to 30,000 psi. For surface applications,

    Cameron equipment ranges from low pressure,

    conventional equipment to systems for severe

    service and geothermal applications.

    And Camerons reputation for quality ensures

    that all wellhead products meet or exceed API 6A

    specifications.

    For equipment requirements not covered in this

    brochure, contact your Cameron representative.

  • 8/10/2019 Conventional Surface Wellheads

    3/21

    S AND IC WELLHEAD SYSTEMS

    Camerons two conventional wellhead systemsthe

    S system and the IC systemare both compatible with

    most Cameron tubing spool and hanger configurations.

    The S Conventional Wellhead System is the indus-

    trys highest capacity conventional spool-type wellhead.

    Designed for use with all well depths and all types of

    completions, the S system may be used in place of the

    IC Wellhead for all applications.

    For a wide range of applications, the IC Wellhead

    System offers a cost-effective, reliable alternative

    designed for less intense conditions.

    SELECTING A WELLHEAD SYSTEM

    The first step in determining which Cameron wellhead

    system is best for your application is to determine the

    casing hanger style to be used. Each hanger profile is

    unique and is generally compatible with only a limited

    number of casing heads and spool bowls.

    The four components to consider when selecting a

    casing hanger are the temperature range, hang-off

    capacity, working pressure and the method used to set

    the annulus seal. Please refer to the charts on this page

    as you select the casing hanger to suit your needs.

    SURFACE SYSTEMS

    MAJOR CONSIDERATIONS FOR CASING HANGER SELECTION

    -20F to 150F (-29C to 65C)

    Temperature Range* -20F to 180F (-29C to 82C)

    -20F to 250F (-29C to 121C)

    Up to 50% of pipe body yield

    Hang-Off Capacity Up to 70% of pipe body yield

    Up to 80% of pipe body yield

    5000 psi WP

    Working Pressure 10,000 psi WP

    10,000 and 15,000 psi WP

    Manual

    Automatic

    Yes

    No

    Single 45 shoulder (IC-2 Series)

    Double 45 shoulder (S Series)

    Method to SetAnnulus Seal

    Seal Replaceablewith Load on Hanger

    Spool/HousingCompatibility

    IC-1

    IC-1-P

    IC-2

    SB-3

    SB-5

    SB-6

    * Note: Although final production may be at one temperature, operating temperature at the casing hanger may be lower.

    CASING HANGER SELECTION CHART

    A

    P

    I

    T

    E

    M

    P

    E

    R

    A

    T

    U

    R

    E

    R

    A

    N

    G

    E

    250F121C

    180F82C

    150F65C

    100F38C

    50F10C

    0F-17C

    -20F-29C

    0 10% 20% 30% 40% 50% 60% 70% 80%

    U T S P

    Hang-Off Capacity (% of Pipe Body Yield)(Operating conditions verified by

    API 6A, 17th Edition, Appendix F testing)

    SB-5

    SB-3

    IC -1IC-1-PIC-2

    SB-6

    3

  • 8/10/2019 Conventional Surface Wellheads

    4/21

    S CONVENTIONAL WELLHEAD SYSTEM

    Designed for use with all well depths and all types of

    completions, the Cameron S Conventional Wellhead

    System offers the industrys highest capacity conven-

    tional spool-type wellhead. The Cameron S Wellhead

    incorporates the lower casing head housing, the casing

    hanger and the subsequent casing head spools and

    hangers. The S system is compatible with any of the

    Cameron tubing spool and hanger configurations

    shown on pages 12-17.

    FEATURES Two 45 shoulders: the upper shoulder

    supports the pack-off hydraulic pressure and test loads,and the lower shoulder provides independent support

    for the casing load. A large selection of secondary seals

    and pack-off bushings provides versatility.

    S CASING HANGER APPLICATION CHART

    A

    P

    I

    T

    E

    M

    P

    E

    R

    A

    T

    U

    R

    E

    R

    A

    N

    G

    E

    250F121C

    180F82C

    150F65C

    100F38C

    50F10C

    0F-17C

    -20F-29C

    0 10% 20% 30% 40% 50% 60% 70% 80%

    U T S P

    Hang-Off Capacity (% of Pipe Body Yield)(Operating conditions verified by

    API 6A, 17th Edition, Appendix F testing)

    N Lock Screw

    T Tubing Hanger

    Tubing Spool

    NX Bushing

    SB-3Casing Hanger

    S Casing HeadSpool

    Single P Seal

    S Casing HeadHousing

    SB-3Casing Hanger

    SB-5

    SB-3

    SB-6

    Cameron S Wellhead System

    Cameron Conventional Wellhead Systems

    4

  • 8/10/2019 Conventional Surface Wellheads

    5/21

    IC CONVENTIONAL WELLHEAD SYSTEM

    For use in less extreme conditions, the Cameron IC

    Conventional Wellhead System incorporates the lower

    casing head housing and hanger and the subsequent

    casing head spools and hangers. Although components

    are not interchangeable, the S Wellhead may be used in

    place of the IC Wellhead for these applications as well.

    The IC Wellhead, like the S Wellhead, is compatible

    with any of the Cameron tubing spool and hanger con-

    figurations shown on pages 12-17.

    FEATURES Straight-bore design with 45 load shoulder.

    A large selection of secondary seals and pack-off bush-ings provides versatility.

    SURFACE SYSTEMS

    IC CASING HANGER APPLICATION CHART

    A

    P

    I

    T

    E

    M

    P

    E

    R

    A

    T

    UR

    E

    R

    A

    N

    G

    E

    150F65C

    100F

    38C

    50F10C

    0F-17C

    -20F-29C

    0 10% 20% 30% 40% 50% 60% 70% 80%

    U T S P

    Hang-Off Capacity (% of Pipe Body Yield)(Operating conditions verified by API 6A,

    17th Edition, Appendix F testing)

    IC-1IC-1-PIC-2

    Cameron IC Wellhead System

    N Lock Screw

    T Tubing Hanger

    Tubing Spool

    NX Bushing

    IC-2 CasingHanger

    IC-2 Casing HeadSpool

    Single P Seal

    IC-2 Casing HeadHousing

    IC-2 CasingHanger

    5

  • 8/10/2019 Conventional Surface Wellheads

    6/21

    CXS(Single)

    C-SRL-CL(Single)

    CD-2N(Dual)

    CD-T(Dual)

    CD-T-CL(Dual)

    MTBS(Metal)

    HT-2(Single)

    HT(Single)

    CD-2(Single or Dual Completions)

    MTBS(Metal)

    C(Single Completions Only)

    S IC-2

    T-CL(Single)

    T(Single)

    Single P Double P Single T Double T NX BushingCANH

    (For use with S spool only)

    IC-1* IC-1-P* IC-2SB-3 SB-5* SB-6

    IC-1* IC-1-P* IC-2SB-3 SB-5* SB-6

    S/IC-2 S-11/IC-2-BP

    S

    CAMFORGE CR Landing Base(Optional)

    Casing BoxThread

    Slip-On Weldwithout O-Ring

    Slip-On Weldwith O-Ring(Standard)

    Slip Lock

    S-3/IC-2-L

    CASINGHANGERS

    Three slip-type casing

    hangers are available for

    the S and IC Casing Head

    Housings. Each hanger

    has a specific application.

    In addition, there are

    mandrel-type casing hang-

    ers available for both bowl

    types.

    CASINGHANGERS

    Three slip-type casing

    hanger designs are

    available for the S and

    IC-2 Casing Spools.

    Each hanger has specific

    applications. In addition,

    there are mandrel-type

    casing hangers available

    for both bowl types.

    BOTTOM CONNECTIONS

    The S and IC-2 Casing Head

    Housings are available with a

    selection of bottom connections

    to match installation requirements.

    CR LANDING BASE

    The CR Landing Base can

    be used with any style

    housing to transfer loads

    to the conductor.

    CASING HEAD HOUSING

    The S and IC-2 Casing Head

    Housings have several options

    for top connections. One option

    features no lock screws; anotherfeatures two lock screws 180

    apart; and the final option

    features multiple lock screws

    depending on the flange size.

    SECONDARY SEALS

    A variety of secondary seals

    are available to fit S andIC-2 Casing Spools as well

    as the C, CD-2 and MTBS

    Tubing Spools.

    TUBING HANGERS

    Tubing hangers are available for single, dual and metal-sealing completions.

    TUBING SPOOLSTwo tubing spool designs are available for standard

    service applications. The CD-2 Tubing Spool has the

    same bowl configuration as the C Tubing Spool and

    is compatible with dual tubing hangers. The MTBS

    Spool is all-metal-sealing for critical applications.

    CASING SPOOLS

    The S and IC-2 Casing Spools have

    several options for top connections.

    One option features no lock screws;

    another features two lock screws

    180 apart; and the final option

    features multiple lock screws

    depending on the flange size.

    IC-2

    S/IC-2 S-11/IC-2-BP S-3/IC-2-L

    Top flange lock screw configurations available for S and IC-2 Casing Spools.

    *Note: Lock screws may not be used with SB-5, IC-1 or IC-1-P slips.

    Top flange lock screw configurations available for S and IC-2 Casing Head Housings.

    *Note: Lock screws may not be used with SB-5, IC-1 or IC-1-P slips.

    Bottom Connections available for S and IC-2 Casing Head Housings

    SURFACE SYST

    Cameron Conventional Wellhead Systems

  • 8/10/2019 Conventional Surface Wellheads

    7/21

    The Casing Head Housing seals off the surface casing

    and provides a landing bowl for the next casing string.

    It also provides an attachment for the BOP stack.

    CASING HEAD HOUSINGBOTTOM CONNECTION OPTIONS

    SLIPLOCK CASING CONNECTION SYSTEM The SlipLock

    Casing Connection System reduces installation time by

    eliminating the need for welding. The system achieves

    the necessary seal using elastomeric T Seals or plastic

    injection-energized P Seals.

    The SlipLock system performs in working pressures

    up to 10,000 psi. Because it is reusable, it is an appropri-

    ate choice for exploration wells.

    CAMFORGE CASING CONNECTION SYSTEM The

    CAMFORGE Casing Connection System requires no

    welding and no pre-machining of the casing. Because

    the casing is mechanically cut, existing production does

    not have to be shut in. The connection is made using

    hydraulic pressure to expand the surface casing and

    housing. The system establishes a pressure-tight, metal-

    S Casing Head Housing

    IC-2 Casing Head Housing

    S/IC-2 S-11/IC-2-BP

    S

    CAMFORGECasing BoxThread

    Slip-On Weldwithout O-Ring

    Slip-On Weldwith O-Ring(Standard)

    Slip Lock

    S-3/IC-2-L

    IC-2

    Top flange lock screw configurations available for S and IC-2 Casing Head Housings.*Note: Lock screws may not be used with SB-5, IC-1 or IC-1-P slips.

    Casing Head Housings

    6

  • 8/10/2019 Conventional Surface Wellheads

    8/21

    CASING HEAD HOUSING COMPARISON

    Bowl Casing Lock Side Bottom Test Injection Landing

    Wellhead Design Hangers Screws Outlets Connections Ports Ports Base

    Straight borewith dual 45

    shouldersS Wellhead

    IC Wellhead

    SB-3, SB-5

    and SB-6

    CR LandingBase

    available

    Includeburied check

    valves

    Metal sealing,designed to

    allow venting

    Casing boxthreads

    Slip-on weld(with and

    without O-ring)

    SlipLock

    CAMFORGE

    Line pipethreaded orstudded withthreads for

    valve removalplugs

    S Housing no lock screws

    S-11 Housing two lock screws180 apart for wear bushing retention

    S-3 Housing full complementof lock screws for casing hanger retention(exact number dependent on flange size)

    Straight borewith single 45

    shoulder

    IC-1, IC-1-P

    and IC-2

    CR LandingBase

    available

    Includeburied check

    valves

    Metal sealing,designed to

    allow venting

    Casing boxthreads

    Slip-on weld(with and

    without O-ring)

    SlipLock

    CAMFORGE

    Line pipethreaded orstudded withthreads for

    valve removal

    plugs

    IC-2 Housing no lock screws

    IC-2-BP Housing two lock screws180 apart for wear bushing retention

    IC-2-L Housing full complementof lock screws for casing hanger retention(exact number dependent on flange size)

    sealing connection suitable for working pressures up

    to 10,000 psi. The CAMFORGE system minimizes rig time

    and the duration of open hole time without BOP

    protection. Annulus hydro-testing simulates working

    conditions prior to BOP nipple-up.

    SLIP-ON WELD Slip-on weld bottom connections are

    standard with O-rings for both S and IC-2 casing heads

    with 10-3/4 or smaller casing preparations. For larger

    casing sizes, the O-ring seal option is not available. The

    O-ring seal requires only one external weld. Slip-on weld

    connections include a 1/2 line pipe test port to validate

    the integrity of both the weld and the O-ring seals.

    CASING BOX THREAD When threaded connections are

    specified for casing heads, casing threads are used. In

    this case, the standardized lower connection outside

    diameter allows use of raw material for either S or IC-2

    style heads.

    CR LANDING BASE The optional CR landing base can

    be used with any style housing to transfer loads to the

    conductor.

    SURFACE SYSTEMS

    SlipLock Casing

    Connection System

    CAMFORGE Casing

    Connection System

    Casing Box Thread Slip-On Weld

    with O-Ring

    CR Landing Base

    (Optional)

    7

  • 8/10/2019 Conventional Surface Wellheads

    9/21

    The casing spool seals off the surface casing string,

    and its landing bowl provides support for the next

    casing string.

    SECONDARY SEALS

    Cameron offers a wide range of secondary seals for use

    in casing and tubing spools. These secondary seals are

    installed in the bottom of spools with corresponding

    preps. Secondary seals include single P Seals, Double P

    Seals, Single T Seals, Double T Seals, NX Bushings,

    X Bushings and proprietary CANH Seals.

    S Casing Head Spool

    IC-2 Casing Head Spool

    S IC-2

    Single P Double P Single T Double T NX BushingCANH

    (For use with S spool only)

    IC-1* IC-1-P* IC-2SB-3 SB-5* SB-6

    S/IC-2 S-11/IC-2-BP S-3/IC-2-L

    Top flange lock screw configurations available for S and IC-2 Casing Spools.*Note: Lock screws may not be used with SB-5, IC-1 or IC-1-P slips.

    Casing Head Spools

    8

  • 8/10/2019 Conventional Surface Wellheads

    10/21

    SURFACE SYSTEMS

    CASING HEAD SPOOL COMPARISON

    Bowl Casing Lock Side Secondary Test Injection

    Wellhead Design Hangers Screws Outlets Seals Ports Ports

    Straight borewith dual 45

    shouldersS Wellhead

    IC Wellhead

    SB-3, SB-5

    and SB-6

    Includeburied check

    valves

    Metal sealing,designed to

    allow venting

    Single P,Double P,Single T,Double T,

    NX Bushing,X Bushing,CANH Seal

    Line pipethreaded orstudded withthreads for

    valve removalplugs

    S Casing Head Spool no lock screws

    S-11 Casing Head Spool two lock screws180 apart for wear bushing retention

    S-3 Casing Head Spool full complementof lock screws for casing hanger retention(exact number dependent on flange size)

    Straight borewith single 45

    shoulder

    IC-1, IC-1-P

    and IC-2

    Includeburied check

    valves

    Metal sealing,designed to

    allow venting

    Single P,Double P,Single T,Double T,

    NX Bushing,X Bushing

    Line pipethreaded orstudded withthreads for

    valve removalplugs

    IC-2 Casing Head Spool no lock screws

    IC-2-BP Casing Head Spool two lock screws180 apart for wear bushing retention

    IC-2-L Casing Head Spool full complementof lock screws for casing hanger retention(exact number dependent on flange size)

    SECONDARY SEALS COMPARISON

    Casing Spool Tubing Spool Maximum Maximum Working Seal Means of

    Model Compatibility Compatibility Service Rating Pressure (psi) Type Energizing Seal

    Single P Seal S, S-11, S-3, IC-2, IC-2-BP, IC-2-L C, CD-2, MTBS Moderately Severe 5000 Elastomeric Plastic Packing

    Double P Seal S, S-11, S-3, IC-2, IC-2-BP, IC-2-L C, CD-2, MTBS Moderately Severe 15,000 Elastomeric Plastic Packing

    SIngle T Seal S, S-11, S-3, IC-2, IC-2-BP, IC-2-L C, CD-2, MTBS Standard 5000 Elastomeric Radial Interference

    Double T Seal S, S-11, S-3, IC-2, IC-2-BP, IC-2-L C, CD-2, MTBS Moderately Severe 10,000 Elastomeric Radial Interference

    X, NX Bushing S, S-11, S-3, IC-2, IC-2-BP, IC-2-L C, CD-2, MTBS Moderately Severe 5000 Elastomeric Plastic Packing

    CANH Seal S, S-11, S-3 C, CD-2, MTBS Severe/Corrosive 20,000 Metal Flange Make-up

    Single P Seal Double P Seal Single T Seal

    Double T Seal NX Bushing CANH Seal

    SECONDARY SEALS

    9

  • 8/10/2019 Conventional Surface Wellheads

    11/21

  • 8/10/2019 Conventional Surface Wellheads

    12/21

    CASING HANGERS FOR IC-2 CASING HEADHOUSINGS AND SPOOLS

    Cameron IC-2 Casing Head Housings and Spools accept

    all three hangers in the IC hanger family. Cameron offers

    a selection of IC hangers using manually energized seals

    or weight-set seals, depending upon application require-

    ments. IC hangers are available in one-piece and two-

    piece designs, so use of IC-2 equipment for different

    applications can be varied by slip selection alone.

    IC hangers land on the single 45 shoulder in IC-2 bowls.

    Mandrel style casing hangers also can be supplied.

    IC-1 CASING HANGER The IC-1 Casing Hanger is an

    independent slip and seal assembly. The slip assembly is

    latched around the casing and lowered into the casing

    head. The seal

    assembly is

    installed over the

    casing after it is cut

    off. Pressure applied

    to the top of the seal

    assembly is transferred to the casing head, not to the

    slips. The IC-1 hanger can be used only in the IC-2 bowl

    profile; it cannot be used with spools provided with

    lock screws.

    IC-1-P CASING HANGER The IC-1-P Casing Hanger is a

    one-piece, non-automatic, wrap-around hanger that is

    ideal for use when casing weight is insufficient to ener-

    gize the hanger

    seal. The seal is

    energized using

    cap screws and can be

    replaced with rated

    load on the hanger.

    This hanger can be used only in the IC-2 bowl profile; it

    cannot be used with spools provided with lock screws.

    IC-2 CASING HANGER The IC-2 Casing Hanger is awrap-around hanger with an annulus seal. This hanger

    is energized by casing weight, which varies with the

    casing and slip

    size. The hanger

    uses a heavy-duty

    latch and hinge design

    that creates a reliable,

    strong and stable

    hanger structure after closing. The hinge mechanism

    enables the hanger halves to pivot out of the way

    during wrap-around. Tapered rough backs allow

    a quick, secure bite of the casing, restrict continued

    downward movement, and prevent collapse of the

    casing. A guide ring maintains slip alignment during

    installation and operation.

    SURFACE SYSTEMS

    IC CASING HANGER COMPARISON

    Spool Hanger Operating Working Rated Load Method to Seal Replaceable

    Model Compatibility Type Temperature Pressure (psi) Capacity Set Seal with Load on Hanger

    IC-1 IC-2IndependentSlip and Seal

    Assembly

    -20 to 150F-29 to 65C

    500050% minimumpipe body yield

    O-Rings Yes

    IC-1-P IC-2Wrap-AroundSlip and Seal

    Assembly

    -20 to 150F-29 to 65C

    10,00050% minimumpipe body yield

    Cap Screws Yes

    IC-2 IC-2, IC-2-BP, IC-2-LWrap-AroundSlip and Seal

    Assembly

    -20 to 150F-29 to 65C

    10,00050% minimumpipe body yield

    Casing Weight No

    11

  • 8/10/2019 Conventional Surface Wellheads

    13/21

    TUBING SPOOLS AND HANGERS

    Camerons wide variety of tubing spools and hangers

    suits all types of completions single, dual, high

    pressure and severe service.

    Cameron uses a standard C profile for tubing spools.

    Use of this profile allows Cameron to offer the widest

    possible array of tubing hanger choices while minimiz-

    ing tubing spool requirements. Of the tubing hangers

    offered, all but one the MTBS (designed for critical

    service applications) fit the C profile.

    Like our wellhead components, all Cameron comple-

    tion components meet or exceed API 6A specifications.

    These products include a full line of completion equip-

    ment and Christmas trees to suit all tubing programs for

    working pressures up to 30,000 psi. From low-pressure

    conventional equipment to systems for severe service

    and geothermal applications, Cameron can supply the

    completion components.

    SELECTING A COMPLETION SYSTEM The first step in

    determining which Cameron completion system is best

    for your application is to determine the tubing hanger

    style to be used (see chart on page 13). Each hanger

    profile is unique and is generally compatible with only

    a limited number of casing head and spool bowls.

    CXS(Single)

    C-SRL-CL(Single)

    HT-2(Single)

    HT(Single)

    C(Single Completions Only)

    T-CL(Single)

    T(Single)

    CD-2N(Dual)

    CD-T(Dual)

    CD-T-CL(Dual)

    CD-2(Single or Dual Completions)

    MTBS(Metal)

    MTBS(Metal)

    Tubing Spools and Hangers

    12

  • 8/10/2019 Conventional Surface Wellheads

    14/21

    SURFACE SYSTEMS

    TUBING SPOOL COMPARISON

    Tubing Completion Bowl Tubing Lock Side Secondary Test Injection

    Spool Type Design Hangers Screws Outlets Seals Ports Ports

    C

    CD-2

    Studded withThreads for ValveRemoval Plugs

    Line Pipe Threadedor Studded withThreads for ValveRemoval Plugs

    Line Pipe Threadedor Studded withThreads for ValveRemoval Plugs

    MTBSSingle,

    Metal Sealing

    Single and Dual

    Single

    Straight Borewith Single 45

    Shoulder

    Straight Borewith Single 45

    Shoulder

    Straight Borewith Single 45

    Shoulder

    MTBS

    CD-2N, CD-TCD-T-CL

    HT, HT-2, C-SRL,T, T-CL, CXS

    Type N

    Type N

    Type N

    Single P, Double P,Single T, Double T,

    NX Bushing,CANH Seal

    Single P, Double P,Single T, Double T,

    NX Bushing

    Single P, Double P,Single T, Double T,

    NX Bushing,CANH Seal

    Metal Sealing,Designed to Allow

    Venting

    Metal Sealing,Designed to Allow

    Venting

    Metal Sealing,Designed to Allow

    Venting

    Include BuriedCheck Valves

    Include BuriedCheck Valves

    Include BuriedCheck Valves

    TUBING SPOOL, TUBING HANGER COMPATIBILITY

    Tubing Hangers Tubing Spools

    C CD-2 MTBS

    HT Tubing Hanger Assembly

    HT-2 Tubing Hanger Assembly

    T Tubing Hanger

    T-CL Tubing Hanger

    C-SRL-CL Tubing Hanger

    CXS Tubing Hanger

    MTBS Tubing Hanger

    MAJOR CONSIDERATIONS FOR TUBING HANGER SELECTION

    Single

    Dual

    Coupling Assembly

    Tubing Hanger Type Mandrel

    Split Dual Mandrel

    5000 psi WP

    10,000 psi WP

    15,000 psi WP

    20,000 psi WP

    Elastomer

    Metal

    Elastomer

    Metal

    No

    Control Line Capability Standard, Continuous

    Optional, Non-Continuous

    Annulus Seal Type

    Working Pressure

    Completion Type

    Neck Seal Type

    T

    T-CL

    HT

    HT-2

    CXS

    CD-2N

    CD-T

    CD-T-CL

    MTBS

    13

  • 8/10/2019 Conventional Surface Wellheads

    15/21

    TUBING SPOOLS FOR SINGLE COMPLETIONS

    Camerons C Tubing Spool is the standard spool for

    single completions in 7-1/16 and 9 nominal top

    flange sizes. The IC-2-L Spool is used for 11 and13-5/8 nominal tubing spools. Features include:

    BOWL DESIGN A straight bore with a single 45

    shoulder design provides support for the tubing load

    and reduces the risk of bowl damage from drill stem

    rotation. This design minimizes hoop load on the spool

    while maintaining high hanging capacity.

    TUBING HANGER COMPATIBILITY The tubing spool

    accommodates a wide variety of tubing hangers for single

    completions including HT, HT-2, C-SRL-CL, T, T-CL and CXS

    designs. See the following page for more information.

    TYPE N LOCK SCREWS Reliable Type N Lock Screws fea-

    ture packing installed in front of the threads to prevent

    any contamination of threads by well-bore fluids and to

    help eliminate build-up of

    solids behind the screw.

    See page 18 for more infor-

    mation on Type N Lock

    Screws.

    SIDE OUTLETS Line-pipe

    threaded and studded out-

    lets are available.

    Studded outlets are

    threaded for valve

    removal plugs.

    SECONDARY SEALS C Tubing Spools are available with

    Single and Double P, Single and Double T, and NX

    Bushing and CANH secondary seals. See pages 8-9 for

    more information.

    TEST AND INJECTION PORTS All test ports are metal

    sealing and are designed to allow venting. Injection

    ports include buried check valves. See page 18 for more

    information.

    TUBING HANGERS FOR SINGLE COMPLETIONS

    The HT and HT-2 Tubing Hanger Assemblies are single

    completion hanger assemblies for use in either the C

    Tubing Spool or the CD-2 Tubing Spool. Both designs are

    made up of a coupling, an adapter and a Type C wrap-

    C Tubing Spool

    around style casing hanger. The HT-2 is the preferred

    design for stainless steel applications. It incorporates a

    suspension nut that allows installation without rotating

    the Christmas tree. Both assemblies are rated up to10,000 psi WP and are easy and quick to install without

    special running tools.

    HT AND HT-2 COUPLINGS Both designs include coarse

    ACME threads, which make up easily with minimum

    risk of damage. Self-energizing seals isolate threads

    from well fluids, allowing testing of the flange ring

    gasket.

    HT AND HT-2 ADAPTERS Both adapter top and bottom

    connections are normally configured with a flanged

    bottom and studded top, providing a test port for veri-

    fication of the adapter flange connection and coupling

    seal integrity.

    HT-2 SUSPENSION NUT The HT-2 Suspension Nut is

    made of a high-strength, low-alloy, gall-resistant mate-

    rial. A coupling seal isolates the nut from flow pressure,

    preventing corrosion.

    C TUBING HANGER The C Tubing Hanger is a wrap-

    around, slip and seal assembly. The annulus seal is ener-

    gized by tubing weight or tie-down screws and controls

    pressure in the casing annulus during installation of the

    Christmas tree.

    The T, T-CL, C-SRL-CL and CXS Tubing Hangers are single

    completion, mandrel-type hangers for use in either the

    C Tubing Spool or the CD-2 Tubing Spool.

    T TUBING HANGER The T Tubing Hanger withstands

    the stress of high pressure and corrosive or erosive ele-

    ments associated with well flow. Its flexible neck main-

    tains the metal seal despite thermal or pressure cycling.

    T-CL TUBING HANGER The T-CL Tubing Hanger with-stands stress of high pressure and corrosive or erosive

    elements associated with well flow. A control line exit

    block is available in either a bull plug style or block nee-

    dle valve style.

    C-SRL-CL TUBING HANGER The C-SRL-CL Tubing Hanger

    incorporates a pressure energized SRL neck seal, which

    accommodates vertical movement in the tubing hanger

    during BOP testing. A control line exit block is available

    Single Completions

    14

  • 8/10/2019 Conventional Surface Wellheads

    16/21

    SURFACE SYSTEMS

    C-SRL-CL Tubing HangerCXS Tubing HangerT-CL Tubing Hanger

    COMPARISON OF TUBING HANGERS FOR SINGLE COMPLETIONS

    Spool Hanger Working Method to Annulus Neck Control BPV

    Model Compatibility Type Pressure (psi) Set Seal Seal Seal Line Preparation

    HT ElastomerC and CD-2Coupling Assembly with

    Type C Wrap-Around Hanger10,000

    RadialInterference

    Elastomer Not Available Standard

    HT-2 ElastomerC and CD-2Rotatable Coupling Assembly

    with Type C Wrap-Around Hanger10,000

    RadialInterference

    Elastomer Not Available Standard

    T ElastomerC and CD-2 Mandrel 15,000 Lock Screws Metal Not Available Standard

    T-CL ElastomerC and CD-2 Mandrel 15,000 Lock Screws Metal Continuous Standard

    C-SRL-CL ElastomerC and CD-2 Mandrel 15,000 Lock Screws Metal Continuous Standard

    CXS ElastomerC and CD-2 Mandrel 10,000 Lock Screws Elastomer Optional Standard

    MTBS MetalMTBS Mandrel 20,000 Lock Screws Metal Continuous Standard

    HT-2 Tubing Hanger AssemblyHT Tubing Hanger Assembly T Tubing Hanger

    in either a bull plug style or block needle valve style.

    The C-SRL-CL hanger should be used in 7-1/1610,000 psi

    Type C Tubing Spools.

    CXS TUBING HANGER The CXS Tubing Hanger includes

    two elastomeric neck seals that may be used to isolate

    one control line.

    15

  • 8/10/2019 Conventional Surface Wellheads

    17/21

    SIDE OUTLETS Spools are available with line pipe

    threaded and studded outlets. Studded outlets are

    threaded for valve removal plugs.

    SECONDARY SEALS CD-2 Tubing Spools are available

    with Single and Double P, Single and Double T and

    NX Bushing secondary seals. See pages 8-9 for more

    information.

    TEST AND INJECTION PORTS All test ports are metal

    sealing and are designed to allow venting. Injection

    ports include buried check valves. See page 18 for more

    information.

    TUBING HANGERS FOR DUAL COMPLETIONS

    Camerons dual completion tubing hangers include

    three designs: the CD-2N Tubing Hanger, CD-T Tubing

    Hanger and CD-T-CL Tubing Hanger. These hangers

    used with the CD-2 Tubing Spoolare split dual man-

    drel style hangers that can be run and pulled independ-

    ently. The alignment slots are located below the load

    shoulder to protect the alignment pins from tubing

    weight, allowing maximum load capacity.

    TUBING SPOOLS FOR DUAL COMPLETIONS

    The CD-2 Tubing Spool features the same bowl as the

    C Tubing Spool but incorporates alignment pins for

    dual completions. The CD-2 also can be used for single

    completions by retracting

    the alignment pins.

    Features include:

    BOWL DESIGN A straight

    bore with a single 45 shoulder

    design provides support for the

    tubing load and reduces

    the risk of bowl damage

    due to drill stem rotation.

    This design minimizes hoop load on the spool while

    maintaining high hanging capacity.

    TUBING HANGER COMPATIBILITY The tubing spools

    accommodate a wide variety of tubing hangers for sin-

    gle completions including HT, HT-2, C-SRL-CL, T, T-CL

    and CXS designs for single completions and the CD-2N,

    CD-T and CD-T-CL hangers for dual completions.

    TYPE N LOCK SCREWS Reliable Type N Lock Screws fea-

    ture packing installed in front of the threads to prevent

    contamination of the threads by wellbore fluids and to

    help eliminate build-up of solids behind the screw. See

    page 18 for more information.

    ALIGNMENT PINS Alignment pins for dual completions

    are located below the load shoulder to avoid test plug

    interference and to provide alignment without reduc-

    ing load shoulder capacity. CD-2NTubing Hanger

    CD-T

    Tubing Hanger

    CD-T-CL

    Tubing Hanger

    CD-2 Tubing Spool

    COMPARISON OF TUBING HANGERS FOR DUAL COMPLETIONS

    Spool Hanger Working Method to Annulus Neck Control BPV

    Model Compatibility Type Pressure (psi) Set Seal Seal Seal Line Preparation

    CD-2 ElastomerCD-2Split Dual Mandrel

    (Two Piece)10,000 Lock Screws Elastomer

    Optional,Continuous

    Standard

    CD-T ElastomerCD-2Split Dual Mandrel

    (One Piece)15,000 Lock Screws Metal Not Available Standard

    CD-T-CL ElastomerCD-2Split Dual Mandrel

    (One Piece)15,000 Lock Screws Metal

    Standard,Continuous

    Standard

    Dual and Critical Service Completions

    16

  • 8/10/2019 Conventional Surface Wellheads

    18/21

    TUBING SPOOLS FORCRITICAL SERVICE COMPLETIONS

    The MTBS Tubing Spool is a single completion, metal-to-

    metal sealing spool for critical service applications to

    20,000 psi WP. Features

    include:

    METAL-TO-METAL SEALING

    The MTBS Tubing Spool

    and MTBS Tubing Hanger

    provide complete metal-to-

    metal sealing. The annulus

    seal is squeezed to contact

    parallel cylindrical sealingsurfaces in the spool bore.

    The annulus seal is set using tubing weight with addi-

    tional pressure load when required. The neck seal is

    energized by flange make up.

    MTBS TUBING HANGER The MTBS Tubing Hanger is

    made of high alloy materials to withstand corrosive

    and high temperature environments. The extended

    neck ensures positive alignment for the seal during

    installation. The hanger is reusable, and the metal

    seals are replaceable.

    BOWL DESIGN A straight bore bowl design provides a

    large through bore and allows a 7-1/16 flange to be

    used over all 7casing strings.

    TYPE N LOCK SCREWS Reliable N Lock Screws feature

    packing installed in front of the threads. This prevents

    contamination of threads by wellbore fluids and helps

    eliminate build-up of solids behind the screw. See page

    18 for more information on N Lock Screws.

    SIDE OUTLETS MTBS Spools are available with studded

    outlets threaded for valve removal plugs.

    SECONDARY SEALS MTBS Tubing Spools are available

    with Single and Double P, Single and Double T and NX

    Bushing and CANH secondary seals. See pages 8-9 for

    more information.

    TEST AND INJECTION PORTS All test ports are metal

    sealing and are designed to allow venting. Injection

    ports include buried check valves. See page 18 for more

    information.

    TUBING HANGERS FOR

    CRITICAL SERVICE COMPLETIONSThe MTBS Tubing Hanger is made of

    high alloy materials to withstand

    corrosive and high temperature

    environments. The extended

    neck ensures positive

    alignment for the seal

    during installation. The

    hanger is reusable, and the

    metal seals are replaceable.

    SURFACE SYSTEMS

    MTBS Tubing Spool

    MTBS Tubing Hanger

    17

  • 8/10/2019 Conventional Surface Wellheads

    19/21

    Test Port

    Injection Port

    (15,000 psi WP and Above)

    LOCK SCREWS, TEST PORTS AND INJECTION PORTS

    N LOCK SCREWS All Cameron spools and housings use

    N Lock Screws. These field-replaceable screws contain

    packing in front of the threads to prevent contamina-

    tion by well bore fluids and build up of solids behind

    the screws, which could prevent proper retraction.

    An external oil seal protects threads from atmospheric

    corrosion.

    TEST PORTS All test ports used in Cameron convention-

    al wellhead equipment meet the standard for API 6A

    Type II metal seal design for safety and reliability.

    These ports can be vented safely and are usable with

    all pressure ratings.

    INJECTION PORTS For casing and tubing spools that

    require injection of sealant to energize or re-energize

    the secondary seal, two styles of fittings are available.

    Each style has a buried ball check (without spring). For

    applications 10,000 psi WP and below, the port features

    a simple plug with a 1 NPT thread. For working pres-

    sures above 10,000 psi WP, the port incorporates a two-

    piece plug with a pressure vent.

    Injection Port

    (10,000 psi WP and Below)

    N Lock Screw

    Auxiliary Equipment

    18

  • 8/10/2019 Conventional Surface Wellheads

    20/21

  • 8/10/2019 Conventional Surface Wellheads

    21/21

    SURFACE SYSTEMS

    PO Box 1212

    Houston, Texas 77251-1212

    USA

    Tel 1-713-939-2211

    Fax 1-713-939-2620

    5 Mondial Way

    Harlington

    Hayes, UB3 5AR

    England

    Tel 44-208-990-1800

    Fax 44-208-990-1888

    No. 2 Gul Circle, Jurong Industrial Est

    Singapore 629560

    Singapore

    Tel 65-6861-3355

    Fax 65-6415-1198

    DRILLING & PRODUCTION SYSTEMS

    PO Box 1212

    Houston, Texas 77251-1212

    USA

    Tel 1-713-939-2211

    Fax 1-713-939-2620

    Learn more about

    Conventional Wellhead Systems at:

    www.c-a-m.com

    HSE Policy Statement

    At Cameron, we are committed ethically, financially and personally to a working environment

    where no one gets hurt, nothing gets harmed.