Upload
nguyenminh
View
218
Download
0
Embed Size (px)
Citation preview
Jim Gingras SOUTHEASTERN CONTROL-M USER GROUP | HTTPS://COMMUNITIES.BMC.COM/GROUPS/SOUTH-EAST-USER-GROUP
Control-M V9 Connectivity Understanding “How To” manage connectivity issues for Control-M V9 Implementations
Control-M V9 Connectivity 1 of 30
TABLE OF CONTENTS
TABLE OF CONTENTS .............................................................................................................................................1
1 OVERVIEW .......................................................................................................................................................2
1.1 Basic Control-M Application Architecture ...........................................................................................3
1.2 Basic Connectivity Testing and Validation ..........................................................................................4
2 ENTERPRISE MANAGER CONNECTIVITY .............................................................................................................7
2.1 Summary.............................................................................................................................................9
3 AGENT CONNECTIVITY................................................................................................................................... 10
3.1 Summary.......................................................................................................................................... 13
4 DESKTOP CLIENT CONNECTIVITY ................................................................................................................... 14
4.1 Summary.......................................................................................................................................... 18
5 AGENTLESS CONNECTIVITY ........................................................................................................................... 19
5.1 Summary.......................................................................................................................................... 21
APPENDICES ......................................................................................................................................................... 22
6 CONTROL-M CONNECTIVITY UTILITIES ........................................................................................................... 22
7 V9 PORTS .................................................................................................................................................... 24
8 PRE-INSTALLATION PORT CONSIDERATIONS ................................................................................................... 25
9 POST INSTALLATION CONNECTIVITY ISSUES ................................................................................................... 26
10 ARCHIVAL CONNECTIVITY ........................................................................................................................... 28
11 SELF SERVICE .......................................................................................................................................... 29
12 ADVANCED TROUBLESHOOTING FOR CONTROL-M V9 CONNECTIVITY ISSUES ................................................ 30
Control-M V9 Connectivity 2 of 30
1 OVERVIEW
Today’s modern IT architectures still take advantage of standard TCP/IP fundamentals that are foundational to application and solution architectures. Whether those solutions are running on servers, virtual machines, or in the cloud. Whether they are being created on conventional hardware and infrastructure or in hybrid converged environments where all devices are virtual as well as their connections or whether the entire environments are being created with tools like Terraform or Dockers. They all rely on the standard Domain Naming Standards running on top of some type of TCP/IP stack that needs to route packets to their destinations.
FIGURE 1: TCP/IP AND THE OSI REFERENCE MODEL
FIGURE 2: TYPICAL DOMAIN NAMING SYSTEM PROCESS This is both powerful and encouraging as we can typically troubleshoot and resolve application level issue with the same tools we always have before the new virtualized world added levels of indirection and complexity that, although unknown to the application, are essential to install and configure applications in a secure and supportable manner, according to standards and best practices.
Control-M V9 Connectivity 3 of 30
1.1 Basic Control-M Application Architecture
A key consideration when determining the installation and implementation requirements for Control-M is that it IS an Enterprise Class Infrastructure application. In other words, this application will be operating and executing workloads across your entire IT Enterprise. Whether that IT Enterprise is internal, external or hybridized with the cloud. Control-M requires TCP/IP communications across all the IT Domains you intend to run your enterprise workload.
FIGURE 3:BASIC CONTROL-M ARCHITECTURE
The diagram above shows the basic Control-M application architecture. It is a three-tiered functional architecture that can be implemented on one server or many depending on the size of the enterprise workload:
Enterprise Manager (EM) – Responsible for user interfaces and coordinating workload across Control-M servers
Control-M Server (CTM) – Responsible for workload execution and management, it is the work load engine that gets the workload done.
Control-M Agents – Responsible for execution of the workload. Control Modules are installed on an agent.
All these components use TCP/IP ports to communicate. Control-M is a mature product that allows customized TCP/IP port definitions, but network and infrastructure SMEs must allow these communications for Control-M to both install and execute in and organizations environment.
Control-M V9 Connectivity 4 of 30
FIGURE 4: ADVANCED CONTROL-M IMPLEMENTATION WITH TCP/IP PORTS
The diagram above shows a very advanced implementation where Terraform is being used to create
and manage Control-M environments in the AWS cloud. However, no matter where the Control-M
environment will ultimately reside, the same TCP/IP Ports must be open and, in some cases, allow bi-
directional communication.
1.2 Basic Connectivity Testing and Validation
Connectivity testing and validation can be broken into three groups coinciding with the three-tiered
architecture. If we consider agentless technology and SSL, SLS, there are other connectivity
considerations in each tier.
Control-M V9 Connectivity 5 of 30
In general use standard TCP/IP tools to help troubleshoot your connectivity issues. These include, but
are not limited to:
Tool Usage Description
PING Ping <DNS name or IP Address> Shows status of basic TCP/IP
service, if enabled, but also test DNS for name resolution
Telnet Telnet<DNS name or IP Address>
<port number>
Shows status of TCP/IP communications on a specific port,
if enabled
Netstat Netstat Shows disposition of TCP/IP
services, usually used with GREP or FINDSTR to limit output
TABLE 1: STANDARD TCP/IP UTILITIES
These three basic utilities can be used on any platform to help determine the status and connectivity of
the Control-M application.
In general, the process will be as follows:
Use PING1 (an icmp ping request) to determine if the components can recognize each other on the network. This will also test whether the Domain Name Service is resolving the IP and Node Names correctly. (Note: ICMP PING requests must be enabled on your network for this command to execute).
Use Telnet to connect to specific ports on the nodes (at the IP Addresses) where Control-M components are installed.
Use Netstat to determine how ports are configured on a specific Server where Control-M is running.
In addition, you may also use other utilities to control the amount of output and give you specific
information such as GREP and FiNDSTR. (e.g. netstat <EM-Server> port | grep <port number>, to get
the status of a Control-M component on that server and that port.
A basic list of the default ports2 for Control-M is provided below.
1 https://en.wikipedia.org/wiki/Internet_Control_Message_Protocol 2 Official BMC V9 Control-M Ports Diagram
Control-M V9 Connectivity 6 of 30
TABLE 2: CONTROL-M TCP/IP PORTS
EM Component Default Ports Description
CORBA Naming Service 13075 + 20 Range of 20 ports for Client
Connectivity, bi-directional with reverse name lookup in the DNS
Web Server 18080 For Self Service, Application Integrator, Workload Change
Manager, bi-directional
Control-M Server 2370 EM to Server, bi-directional
Configuration Manager 2369 EM to Server (and other EM if HA),
bi-directional
Agent to Control-M Server 7005 Job management and commands
Control-M Server to Agent 7006 Job management
Database Ports
Oracle – 1521
MSQL – 1433
Postgres - 5432
Default database Ports
Control-M V9 Connectivity 7 of 30
2 ENTERPRISE MANAGER CONNECTIVITY
Because the Enterprise Manager is the first part of a Control-M installation, troubleshooting connectivity issues generally starts with that component. The Enterprise Manager requires the following ports to be open and, depending on the component, bi-directional. From the diagram above3, these are:
EM Component Default Ports Description
CORBA Naming Service 13075 + 20
Range of 20 ports for Client Connectivity, bi-directional with
reverse name lookup in the DNS
Web Server 18080 For Self Service, Application Integrator, Workload Change
Manager, bi-directional
Control-M Server 2370 EM to Server, bi-directional
Configuration Manager 2369 EM to Server (and other EM if
HA), bi-directional
Database Ports
Oracle – 1521
MSQL – 1433
Postgres - 5432
Default database Ports
TABLE 3: CONTROL-M EM TCP/IP PORTS
The CORBA4 Naming Service will be covered under the Desktop Client Communications, and the Agent ports will be covered under the Agent Connectivity.
The main components are the Control-M Enterprise Manager (EM) to the Control-M Server (CTM) and the Web Server ports, if you are implementing any of the web-based interfaces for Control-M.
Control-M uses the gateway process on the EM to manage communications with the Control-M servers.
3 Official BMC BMC Control-M Ports Diagram . 4 http://www.corba.org/
Control-M V9 Connectivity 8 of 30
FIGURE 5: ARCHITECTURE
There are two database instances, one for the EM dB and one for the CTM dB. This diagram shows
some of the process communication for the EM.
FIGURE 6: USEFUL INFORMATION FOR EM
Control-M V9 Connectivity 9 of 30
Training Video: Connect with Control-M: Troubleshooting the Enterprise Manager Gateway -
https://www.youtube.com/watch?v=UWIdW8PHOKU
2.1 Summary
In keeping with our previously defined troubleshooting process we will:
PING the EM and CONTROL-M servers from each other to make sure DNS can resolve the names and IP addresses correctly.
Use Telnet from the EM to CTM and from CTM to EM to make sure you can connect.
Use NETSTAT to port 2370 on the Control-M Server to make sure a listener process from Control-M is up and running and can connect and from the EM server to the Control-M Server.
Use NETSTAT to port 2369 on the Control-M Server to make sure a listener process from Control-M is up and running and can connect and can connect and from the EM server to the Control-M Server.
There are other tools within Control-M as discussed in the video, but these are basic tests with basic
TCP/IP tools that need to work before Control-M can connect.
Control-M V9 Connectivity 10 of 30
3 AGENT CONNECTIVITY
FIGURE 7: BASIC CONTROL-M PORTS FOR ORACLE DB FOCUS ON SERVER TO AGENT CONNECTIVITY
Control-M Agent Connectivity occurs between the Control-M Server and the Control-M Agents in the
environment. This is generally the most over-arching concern because these agents are installed on
servers across your enterprise wherever jobs in your enterprise workload will be executed, whether in
the cloud, on the internal or external network.
13075 + 20
Oracle
Oracle DB
instance
CTM DB
20Gb
Oracle
Oracle DB
instance
EM DB
20Gb
Control-M server contents
engine
Control-M Agent
Control-EM server contents
Control-M Enterprise Mgr.
Web Svr: 18080
Internet
users
VP
N
Firewall
Control-M Agents
Workload Servers
Control-M V9 Connectivity 11 of 30
FIGURE 8: AGENT ARCHITECTURE
For agents this, by default, these communications take place over ports 7005 and 7006. The diagram
shows the processes that run as the agent for Control-M.
FIGURE 9: PERSISTENT AGENT COMMUNICATION
Control-M V9 Connectivity 12 of 30
If you are using a persistent connection for agents the is also a router component included in the agent
processes to keep communications going.
The Control-M Configuration Manager (CCM) is the preferred method of managing the status of the
Control-M server and its agents. Unfortunately, if we are having connectivity issues the CCM is not
always available. In those cases, Control-M comes with a number of utilities to assist in determining
the status of the communications between the server and the agents under its control.
These include:
Utility Description
Control-M/Server
ctm_agstat Lists or updates the status of a Control-M/Agent.
ctm_diag_comm Generates a report on the connection details of a Control-M/Agent and its
remote host computer.
ctmhostmap Manages the mapping of remote hosts to Control-M/Agents and the
conversion of Control-M/Agents to remote host computers.
ctm_menu
(Agent status)
Converts a remote host to a Control-M/Agent computer
ctmhostgrp Enables the maintenance and viewing of host groups.
ctmping Collects configuration information about Control-M/Agents and test
communications.
shut_ctm Shuts down Control-M/Server and its processes.
ctm_menu
(parameter
customization)
Sets the communication mode to persistent between Control-M/Server
and Agent.
Control-M/Agent
ag_diag_comm Verifies communication between Control-M/Agent and Control-M/Server.
ag_ping Verifies that Control-M/Server is active on computer connected to a
Control-M/Agent.
shagent Shows if an agent and tracker are running.
TABLE 4: SERVER AND AGENT UTILITIES
Control-M V9 Connectivity 13 of 30
FIGURE 10: SUMMARY
The training video provides generous detail and examples of how to use these utilities to troubleshoot
connectivity issues with Control-M and its agents:
Connect with Control-M: Agent Connectivity - https://www.youtube.com/watch?v=KnI9SQOfbQ4
3.1 Summary
In keeping with our previously defined troubleshooting process we will:
PING the Agent Server(s) and CONTROL-M servers from each other to make sure DNS can resolve the names and IP addresses correctly.
Use Telnet from the Agent Server(s) to CTM and from CTM to EM to make sure you can connect.
Use NETSTAT to port 7006 on the Control-M Server to make sure a listener process from Agent-M is up and running and can connect to the Control-M Server.
Use NETSTAT to port 7005 on the Agent Server(s) to make sure a listener process from Control-M Server is up and running and can connect.
There are other tools within Control-M as discussed in the video, but these are basic tests with basic
TCP/IP tools that need to work before Control-M can connect.
Control-M V9 Connectivity 14 of 30
4 DESKTOP CLIENT CONNECTIVITY
FIGURE 11: BASIC CONTROL-M PORTS FOR ORACLE DB FOCUS ON EM TO DESKTOP CLIENT
CONNECTIVITY
13075 + 20
Oracle
Oracle DB
instance
CTM DB
20Gb
Oracle
Oracle DB
instance
EM DB
20Gb
Control-M server contents
engine
Control-M Agent
Control-EM server contents
Control-M Enterprise Mgr.
Web Svr: 18080
Internet
users
VP
NFirewall
Control-M Agents
Workload Servers
Control-M V9 Connectivity 15 of 30
FIGURE 12: CONTROL-M DESKTOP CLIENT ARCHITECTURE
Control-M Naming Services use CORBA5 to facilitate communications with Desktop Clients. The
Desktop Clients communicate with EM components and to provide administrative and workload
management capabilities. The main component that communicates with the Desktop Clients is the GUI
Server on the EM.
Control-M recommends at least a range of 20 ports for the communications between the EM and the
Desktop clients. The actual number required will depend on the number of Desktop Clients running in
your environment.
CORBA requires some specific DNS characteristics and Control-M resolves component locations using
server names, not just IP address. This requires reverse DNS lookup6 or reverse DNS resolution on
the network.
BMC provides two utilities to assist in managing CORBA ports, ORBCONFIGURE and ORBADMIN.
ORBCONFIGURE is a GUI interface that enables users to visualize how CORBA ports are being
configured and is generally more “friendly” to use. (It requires X server on Linux/UNIX Operating
systems). ORBADMIN is a command line utility that is good for scripting or power users. Both utilities
are able to configure CORBA ports for Control-M.
5 CORBA® is the acronym for Common Object Request Broker Architecture™, OMG®'s open, vendor-independent
architecture and infrastructure that computer applications use to work together over networks.
6 https://en.wikipedia.org/wiki/Reverse_DNS_lookup
Control-M V9 Connectivity 16 of 30
The following process should be used to avoid confusion when configuring CORBA ports with either
tool.
CHECK the status of the Naming Service (<orbadmin ns list> command)
STOP Naming Services on the DESKTOP
Configure Naming Services on the DESKTOP
START Naming Services on the DESKTOP
FIGURE 13: CONFIGURING CORBA7
The diagram shows the ORBCONFIGURE GUI as it is running. It also shows the files on the
Enterprise Manager that are accessed by the ORBCONFIGURE and ORBADMIN utilities.
7 https://documents.bmc.com/supportu/ctrlm9/help/Main_help/en-US/index.htm#89782.htm
Control-M V9 Connectivity 17 of 30
`
FIGURE 14: TROUBLESHOOTING REVIEW
The figure above shows a sample workflow where connectivity for Naming Services is checked on both
the Desktop client and EM server.
FIGURE 15: DESKTOP CLIENT KAS
The figure shows some Knowledge Articles that may provide additional information about the scenario
you are seeing in your environment.
Control-M V9 Connectivity 18 of 30
Additionally, the following video shows generous detail on troubleshooting Desktop Client Connectivity
issues:
Connect with Control-M: Client Connectivity - https://www.youtube.com/watch?v=AyeOG50OJTc
4.1 Summary
In keeping with our previously defined troubleshooting process we will:
PING the Remote Desktop Client(s) and EM servers from each other to make sure DNS can resolve the names and IP addresses correctly.
Use Telnet from the Remote Desktop Client(s) to the EM to make sure you can connect.
Use ORBCONFIGURE and ORBADMIN to ensure CORBA is configured
There are other tools within Control-M as discussed in the video, but these are basic tests with basic
TCP/IP tools that need to work before Control-M can connect.
Control-M V9 Connectivity 19 of 30
5 AGENTLESS CONNECTIVITY
If you are going to use the agentless functionality in Control-M, then this section applies to you.
FIGURE 16: AGENTLESS ARCHITECTURE
Figure 19 shows a high-level architecture for agentless configuration in Control-M. Two considerations:
The remote agents are defined to a Control-M Agent
If the agents are running on the Windows platform, it is possible to use WMI rather than SSH to communicate with the smart device the jobs will execute on.
Control-M V9 Connectivity 20 of 30
FIGURE 17: AGENTLESS CONSIDERATIONS
The figure above shows the requirements for running agentless.
FIGURE 18: TROUBLESHOOTING
If you are experiencing connectivity issues with agentless functionality check the troubleshooting list to
help identify the issue and remediate it.
Control-M V9 Connectivity 21 of 30
FIGURE 19: KNOWLEDGE ARTICLES
For further assistance there is a video at:
Connect with Control-M: Using Agentless: https://www.youtube.com/watch?v=chzt9xEP8Z8
5.1 Summary
In keeping with our previously defined troubleshooting process we will:
PING the Agentless servers from the Control-M Agent Server(s) and vice versa to make sure DNS can resolve the names and IP addresses correctly.
Use Telnet from the Remote Agentless Server(s) to the Control-M Agent Server to make sure you can connect.
There are other tools within Control-M as discussed in the video, but these are basic tests with basic
TCP/IP tools that need to work before Control-M can connect.
Control-M V9 Connectivity 22 of 30
APPENDICES
6 CONTROL-M CONNECTIVITY UTILITIES
The communication, startup, and troubleshooting utilities are used to set up communication between Control-M
components, startup/shut down Control-M components and entities and determine if communication between the
components is occurring effectively. Various troubleshooting utilities are also included here.
By including a utility command in the command line of a job processing definition, you can run the utility at a
predetermined time or under a predetermined set of conditions without being present.
Some of the parameter names changed for Control-M version 8.0.00 and above, terminology from previous
versions is still supported. For a complete list of the parameter names, see Abbreviations and conventions.
Utility Description
Control-M/Server
ctl Checks if Control-M/EM Server components are operational and send
commands.
orbadmin Manages the Naming Service process and the CORBA configuration file.
ctm_agstat Lists or updates the status of a Control-M/Agent.
ctm_diag_comm Generates a report on the connection details of a Control-M/Agent and its
remote host computer.
ctmgetcm Collects and displays Control-M/Agent application information.
ctmhostmap Manages the mapping of remote hosts to Control-M/Agents and the
conversion of Control-M/Agents to remote host computers.
ctm_menu
(Agent status)
Converts a remote host to a Control-M/Agent computer
ctmhostgrp Enables the maintenance and viewing of host groups.
ctmping Collects configuration information about Control-M/Agents and test
communications.
ctmshout Issues a Shout message to a specified destination.
ctmshtb Sets the active Shout Destination folder.
ctmspdiag Prints or erases diagnostics from stored procedures and set or show
diagnostic request status of stored procedures.
ctmsuspend Suspends Control-M/Server scheduling processes for mass
uploads/downloads from Control-M/EM.
init_prflag Resets sleep times and trace levels for Control-M/Server processes.
Control-M V9 Connectivity 23 of 30
shut_ca Shuts down the Control-M/Server Configuration Agent.
shut_ctm Shuts down Control-M/Server and its processes.
show_ca Displays the status of Control-M/Server Configuration Agent.
shutdb Shuts down the SQL database server.
start_ca Starts up the Control-M/Server Configuration Agent.
start_ctm Starts up Control-M/Server.
startdb Starts up the SQL database server.
ctm_pause Stops Control-M/Server from submitting jobs.
ctmchangeshdir Changes the shared directory path that is used for the PostgreSQL
replication in a high availability environment.
ctm_menu
(parameter
customization)
Sets the communication mode to persistent between Control-M/Server
and Agent.
Control-M/Agent
ag_diag_comm Verifies communication between Control-M/Agent and Control-M/Server.
ag_ping Verifies that Control-M/Server is active on computer connected to a
Control-M/Agent.
shagent Shows if an agent and tracker are running.
TABLE 5: CONTROL-M V9 COMMUNCATIONS UTILITIES
Control-M V9 Connectivity 25 of 30
8 PRE-INSTALLATION PORT CONSIDERATIONS
As security becomes more and more significant when building and managing services and the applications that make them up, ALL port considerations must be taken into account.
Many software vendors, including BMC, take advantage of what is called the Echo Protocol.8 For ICMP messages the Echo protocol communicates over port 7, but can also communicate over port 9.
This creates a requirement to open one or both ports for the installation to complete successfully.
When managing applications and services “in the cloud”, this becomes a requirement.
8 https://en.wikipedia.org/wiki/Echo_Protocol
Control-M V9 Connectivity 26 of 30
9 POST INSTALLATION CONNECTIVITY ISSUES
BMC Control-M recognizes the vulnerability of requiring a more static IP configuration for Control-M to function efficiently and consistently. This is not a problem or “bug” just a requirement for workload automation because of its’ an automation engine that automates workflows across the entire enterprise infrastructure, whether local or remote, on premise or in the cloud, or both.
Control-M includes a GUI based tool that automates changes to the Control-M connectivity configuration based on the environment it is running in.
FIGURE 21: CONNECTIVTY TROUBLESHOOTIN IN WLA GUI9
Select Connectivity Troubleshooting from the tools menu.
FIGURE 22: TROUBLESHOOTING CONNECTIVITY OPTIONS FORM
9 http://win-c191afttulu:18080/help/Main_Help/en-US/#Tools_Troubleshooting.htm
Control-M V9 Connectivity 27 of 30
The Troubleshooting Connectivity dialogue box appears. The selections from the troubleshooting form are not intuitive but designed to let you test them individually and find out which form of connectivity definitions work best in your environment.
1. Select one of the following:
▪ Use Specific IP Address: Enables you to select an IP addresses from enabled network
interfaces on the computer.
▪ Use IP Address Matching Specific Mask - Enables you to specify an IP mask.
This option is recommended when using VPN connections, since the IP addresses might change
dynamically. This avoids the need of reconfiguring CORBA each time you reconnect. (For
example, at runtime the subnet mask 137.72.114.0 will prefer the IP address 137.72.114.142 to
192.168.241.3.) In the configuration file, the mask is set in the –PreferIPMask parameter, and
the hostname_in_ior value is $IP (which is evaluated at runtime). If this option is selected, the
$IP characters appear in the Troubleshoot Connectivity window; accidentally deleting them
prevents the mask from being evaluated at runtime.
▪ Use Virtual Hostname or IP Address - Enables you to set a virtual hostname (for
example, on a cluster machine), a known hostname, or a fixed IP address.
▪ Use Default - Sets the current default hostname or IP address in brackets. In the CORBA configuration file, the value of the –ORBDottedDecimalAddresses parameter determines
whether the default is an IP address (value = 1) or a hostname address (value = 0).
2. Clear the Use bidirectional communication checkbox.
This forces the server to resolve the client’s address and initiate a connection back to it.
An example of when this is helpful is when you are working remotely or have changed how you connect to Control-M.
Control-M V9 Connectivity 28 of 30
10 ARCHIVAL CONNECTIVITY
The Archival Add-On Control Module for Control-M also uses TCP/IP ports to pass log and output files to the Archival repository or database. Depending on how Archival is installed, for instance, if it is on a separate server (which is the case most of the time). There are other ports that must be opened to for Archival traffic. The ports can be customized in a file. See info from knowledge articles below.
“Control-M Workload Archiving is a Java application and it implements the CORBA communication with JacOrb 3rd party.
JacORB has a configuration file named jacorb.properties and default settings are used.
When Control-M Workload Archiving starts and sets up its CORBA communications, it publishes itself via hostname in a
default way and using a default port range.
The host and/or ports published to CORBA are blocked by the firewall and need to opened. The ports need to be configured
for a specific range.”10
11Ensure that the following components are allowed through the firewall:
1. Control-M Enterprise Manager Server CORBA Naming Service
2. EM Configuration Agent - both Primary and Distributed instances
3. EM GUI Server
4. EM Gateway - All gtw's
Once the components are allowed through the firewall we need to configure hostports from the Control-M Enterprise Manager:
Open the Control-M Configuration Manager (CCM)
Choose Tools -> System Configuration -> Control-M\EM System Parameters -> Advanced
Find Name: hostport
Select one of the template "hostport" and click the '+'
Define all GTW:
Name: HostPort
Value: {em hostname}:port
Type: Gateway
Name: {gateway name}
Host: {hostname where the gtw runs}
Define Configuration Agent for the Primary:
Name: HostPort
Value: {em hostname}:port
Type: Config Agent
Name: *
Host: {hostname where the CA runs}
Define the Configuration Agent for the Distributed instance:
Name: HostPort
Value: {distributed em hostname}:port
Type: Config Agent
Name: *
Host: {hostname where the CA runs}
Define the GUI Server:
Name: HostPort Value: {em hostname}:port Type: GUI Server Name: {GUI server name} Host: {hostname where the GUI server runs} After this configuration the Archiving Server and each CA, GUI Server, GTW that have had a hostport defined will need to be recycled.
10 https://communities.bmc.com/docs/DOC-62441 11 https://communities.bmc.com/docs/DOC-49473
Control-M V9 Connectivity 29 of 30
11 SELF SERVICE
Self Service is generally installed over HTTPS. If this is the case, then the web server must also have port 1443 open for the HTTPS traffic.
There are some limitations in terms of the number of jobs to display. There are plans to address this12.
Here is a list of some common questions for Self Service: https://communities.bmc.com/community/bmcdn/enterprise_scheduling_workload_automation/blog/2017/01/18/trending-in-support-self-service-9-new-interface-webinar-qa
FIGURE 23: SELF SERVICE TIPS AND TRICKS
https://bmcsites.force.com/casemgmt/sc_KnowledgeArticle?sfdcid=kA014000000doe1CAA&type=FAQ
https://bmcsites.force.com/casemgmt/sc_KnowledgeArticle?sfdcid=kA014000000dnrOCAQ&type=FAQ
12 https://communities.bmc.com/docs/DOC-77960
Control-M V9 Connectivity 30 of 30
12 ADVANCED TROUBLESHOOTING FOR CONTROL-M V9 CONNECTIVITY ISSUES
Do to the broad connectivity requirements of an enterprise class tool, and because of the extreme requirements of security there are situations that require the ability to examine network traffic and a lower level to determine what is being sent and what is being blocked. Fortunately, there are tools designed to help with these scenarios.
TCPDUMP13- Tcpdump prints out a description of the contents of packets on a network interface that match the boolean expression; the description is preceded by a time stamp, printed, by default, as hours, minutes, seconds, and fractions of a second since midnight. It can also be run with the -w flag, which causes it to save the packet data to a file for later analysis, and/or with the -r flag, which causes it to read from a saved packet file rather than to read packets from a network interface. It can also be run with the -V flag, which causes it to read a list of saved packet files. In all cases, only packets that match expression will be processed by tcpdump.
If you are installing in the AMAZON Cloud, there are also the AMAZON Logs14
If you are installing in the Microsoft Azure Cloud, there are Azure log analytics.15
All these tools require a good bit of knowledge and patience to identify and diagnose information specific to TCP and the respective network configuration.
Basically, you need a timeframe, and specific TCP/IP information about the source and destination on the network to use them.
13 http://www.tcpdump.org/tcpdump_man.html ; http://www.ijsett.com/images/Paper11(5).pdf 14 https://aws.amazon.com/about-aws/whats-new/2014/07/10/introducing-amazon-cloudwatch-logs/ 15 https://docs.microsoft.com/en-us/azure/app-service/web-sites-enable-diagnostic-log