33
CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE

CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

Embed Size (px)

Citation preview

Page 1: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

CONCIERGE 100PROFESSIONAL SERIESELECTRONIC DEADBOLT

USER GUIDE

Page 2: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

IMPORTANT SAFETY INFORMATION 1TOOLS NEEDED FOR NEW INSTALLATION 2COMPONENTS OF ELECTRONIC KEYPAD DEADBOLT 3DOOR PREPARATION 4 - 7INSTALLATION 8 - 13OVERVIEW OF FUNCTIONS 14KEYPAD LIGHTS & WARNINGS 15CODES INFORMATION 16PROGRAMMING 1.AUTOMATICBOLTDIRECTIONADJUSTMENT 17 2.CHANGEPROGRAMMINGCODE 18 3.ADD/DELETEUSERENTRYCODE 19 4.DELETEALLUSERENTRYCODESATONCE 20 5.TEMPORARILYDISABLEALLUSERCODES 21 6.CREATEADISPOSABLEUSERENTRYCODE 22 7.“AUTOLOCK”FUNCTION 23 8.MUTEON/OFF 24 9.RESTOREFACTORYSETTING 25OPERATION 26 - 27TROUBLESHOOTING GUIDE 28 - 29 INFORMATION PAGE 30 WARRANTY 31

CONTENTS

Page 3: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

IMPORTANT SAFETY INFORMATION

! WARNING1. Donotuseanyabrasivesoranychemicalproductscontaininganysubstanceofalcohol,benzene,

hydrochloricacidornitricacid,andavoidsharporscratchingobjectstocleanthislockset.2. Donotletanywaterorliquidintolocksetduringinstallationprocess.

! IMPORTANT SAFETY INSTRUCTION1. Donotattempttodisassembleanyinternalcomponentsofthelocksetpersonally.Youmayrunthe

riskofvoidingthelimitedwarranty.2. Donotdroporhitthelockset.3. Donotusesharpobjectstopresskeybuttons.4. Alwayscreateabackupofinformationyouwanttokeep(suchasprogrammingcodeanduse

codes).Pleaseusethelastpageofthisbookletasyourreference.5. Pleasechangeprogrammingcodebeforeoperatingthislockset.

! CARE AND MAINTENANCEThe following care instructions should be followed to ensure a long lasting finish:1. Removelocks,ordonotinstalllocks,priortopaintingyourdoor.2. Periodicallycleanwithmildsoapandasoftclothonly.

®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.1

Page 4: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

• PENCIL• CHISEL• TAPEMEASURE• HAMMER• PHILLIPSSCREWDRIVER• 1”(25mm)&1/8”(3mm)DRILLBITS• 2-1/8”(54mm)HOLEBORINGKIT• POWERDRILL• 2”(51mm)6DCOMMONNAIL• 4-AA1.5VALKALINEBATTERIES

TOOLS NEEDED FOR NEW INSTALLATION

2 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.

Page 5: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.3

COMPONENTS OF ELECTRONIC KEYPAD DEADBOLT

INTERIORBATTERYCOVER

WOODSCREWS

METALSCREWS

MOUNTINGBOLTS

MOUNTINGPLATE

INTERIORASSEMBLY

WOODSCREWS

LATCHRUBBERGASKET

CYLINDERTORQUEBLADE

CYLINDEREXTERIORASSEMBLY

ICWIRE

Page 6: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

4 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.

TEMPLATE

CENTERLINE

MARKDOOREDGEAPPROXIMATELY3”TO6”(75mmTO150mm)ABOVETHEENTRYKNOBORLEVER

DOOR PREPARATION1 MARK DOOR WITH TEMPLATE (ATTACHED SEPARATELY)

Note: If replacing an existing lock or installing in a pre-drilled door, begin with page 8. a. UseTEMPLATEtomarkcenterlineondoorfordeadboltabout3”to6”(75mmto150mm)above theexistingknoborlever. b. Standsodoorswingstowardsyou.Aligntemplateoncenterlineandfoldtemplateasshown.

Page 7: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

CENTERLINE

BACKSET

DRILL1/8”(3mm)PILOTHOLE

1”(25mm)

2-1/8” (54mm)

DRILL1/8”(3mm)PILOTHOLE

®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.5

DOOR PREPARATION

2 MARK AND DRILL PILOT HOLES Selectbackset.Markanddrillpilotholes asshown.

Page 8: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

6 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.

DOOR PREPARATION

3 USING THE TEMPLATE MARKS AS A GUIDE a. Drilla2-1/8”(54mm)holeonthedoorfacefrombothsidestopreventwoodfromsplitting. b. Drilla1”(25mm)holeinthedooredgeforthelatch. c. Usethelatchfaceplateasapatternforthemortiseandpilotholes.Chisel1/8”(3mm)deep. Faceplateshouldfitflush. Note: for drive-in latch, simply insert latch.

a. b. c.

2-1/8”(54mm)

1”(25mm)

FACEPLATE

OUTLINE

CHISEL1/8”(3mm)DEEP

Page 9: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.7

DOOR PREPARATION

4 PREPARE DOOR JAMB AND INSTALL STRIKE PLATE a. Toidentifythecenterofthestrike:insertthelatch,closethedoor; usingthelatchfaceplateasaguide,markhorizontalcenterlineand outlineofthestrike.Ensurethecenterofthefaceplateandthe centerofthestrikearealigned. b. Chisel5/64”(2mm)deepalongthestrikeoutlinetoallowthestrike tobealignedwiththedoorframe. c. Insertthestrikeandtightenitwithwoodscrews.

Door jamb hole dimension a. 1-3/16(30mm) b. 1-3/8”(35mm) c. 1”(25mm)

Strike dimension d. 9/32”(7mm) e. 2-15/16”(75mm) f. 1-5/16”(33mm)

a.

b.

c.

A

B

C

D

E

F

Page 10: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

8 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.

INSTALLATION 6 WAY LATCH

1 6 WAY LATCH To Change Latch Faces1. Useaflat-headscrewdrivertoseparate

thefaceplateformthebackplate.2. Snaptheselectedfaceplateontothe

backplate.

Latch Backset AdjustmentTorotatethelatchcaseasfollowingillustrationforbackset2-3/4”(70mm)orreversedirectionfor2-3/8”(60mm)

Drive-in InstallationMakesuretheroundfaceplateisproperlyalignedasillustratedandsnapittothelatchcase. DRIVE-INLATCH

2-3/4”(70mm)

Page 11: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

1B

®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.9

INSTALLATION

2 INSTALL LATCH IN MORTISED AREA OR DRIVE-IN LATCH Ifyourdoorissetuptouseastandardtypelatch,pleaseinstallitwiththe3/4”(20mm)screws thatareprovided.Ifyouusethedrive-inlatch,pleasetapitintoplace.

BACKSET

FACEPLATE

3/4”(20mm)WOODSCREWS

OR

DRIVE-INLATCH TAPLATCHFLUSH

WOODBLOCK(NOTINCLUDED)

Page 12: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

10 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.

INSTALLATION

3 a. Makesurelatchisinretractedposition. b. Insertthecylinderintoexteriorassemblywithcylindertorquebladeinsertedthroughhubofthe latchinahorizontalposition. c. PasstheICwireunderthelatchtotheinteriorsideofthedoor.

a. b. c.

ICWIRE

Page 13: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.11

INSTALLATION

4 INSTALL INSIDE THE MOUNTING PLATE a. CarefullypasstheICwirethroughthewirehole onthemountingplate. b. Makingsurethattheexteriorassemblyand cylinderarepressedflushagainsttheexterior door,insertthemountingboltsandtighten. c. Checktheverticalalignmentforthemounting plateandexteriorassembly. d. Test.Usingthekey,retractandextendthebolt afewtimestotestforsmoothaction. e. Ifactionfeelsrough,loosenscrewsandrealign themountingplateandexteriorassembly.

KEEPPARALLEL

MOUNTINGPLATE

MOUNTINGBOLTS

ICWIRE

Page 14: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

12 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.

INSTALLATION - DOOR HANDING

5 IDENTIFY THE DOOR HANDING a. Facethedoorfrominside b. Thedooris“left-handed”ifthehingesareonthelefthandsideofthedoor. c. Thedooris“right-handed”ifthehingesareontherighthandsideofthedoor.

6 ADJUST INTERIOR TURN PIECE a. Turntheturnpiecetotheleftwhenitisa“right-handed”door. b. Turntheturnpiecetotherightwhenitisa“left-handed”door.

LEFT-HANDED RIGHT-HANDED

INTERIOR

EXTERIOR

HINGEDOOR

Page 15: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.13

INSTALLATION - RECEIVER MODULE

7 INSTALL RECEIVER MODULE a. Removethebatterycover(pushitupandpullitout). b. ConnecttheICwiresandensurethecylindertorquebladeisengagedwiththeturnpiecethen attachtheinteriorassemblytothedoorwiththemetalscrews. c. Insert4(AA)1.5Valkalinebatteriesandplacethecoverbackontotheinteriorassembly.

BATTERYCOVER

METALSCREWS

WOODSCREWS

a. b. c.

Page 16: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

14 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.

OVERVIEW OF FUNCTIONS

1. PROGRAMMING BUTTON ProgrammingButtonisforenteringcodes, clearingerrors,andsettingfunctions. It’salsoa“Lock”Button.2. KEYPAD WITH NUMBER BUTTONS Forinputtingcodes,4-10digitsinlength.3. CYLINDER Retract/Expandlatchboltbykeyfromoutside.4. RUBBER GASKET Topreventwaterleakingthrough exteriorassembly.5. BATTERY COVER6. BATTERY HUB Four(AA)AlkalineBatteries (soldseparately)7. “R” BUTTON (RESET) Restoredefaultsetting8. TURN PIECE Retract/Expandthelatchbolt frominside.

1

2

3

4

6

7

8

5

Page 17: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.15

KEYPAD LIGHTS & WARNINGS

LED INDICATOR LIGHT1. Flashes“Green”oncewhenoperatingfunctionisperformedproperly.2. Flashes“Green”twicewhenprogrammingfunctionisperformedproperly.3. Flashes“Red”threetimeswhenoperatingfunctionwasnotperformedproperly.4. Flashes“Red”fivetimesfollowingfiveunauthorizedentryattempts-thekeypadwillbedisabledfor

45seconds.5. Flashes“Orange”threetimeswhensystemwasrestoredtodefaultsetting.6. Flashes“Orange”slowlywhileinprogrammingmode.

AUDIO WARNINGS1. One“Beep”-operatingfunctionwasperformedproperly.2. Two“Beeps”-programmingfunctionwasperformedproperly.3. Three“Beeps”-operatingfunctionwasnotperformedproperly.

LOW BATTERY WARNINGLEDindicatorflashes“Red”andconstant“Beep”soundisonfor10seconds.Pleasereplacebatteries.

Note: • The lock can still be operated via regular key. • All settings are stored in the memory and will not be affected even when the batteries are replaced.

Page 18: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

16 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.

CODE INFORMATION

PROGRAMMING CODE1. Programmingcodeprovidesabilitytoprogram/reprogramthedeadbolt,andchange/delete/add

individualusercodes.2. Programmingcodecannotbeusedtounlockthedeadbolt.3. Onlyoneprogrammingcodeisallowed,4-10digitsinlength.4. Thefactorypresetprogrammingcodeis0-0-0-0,andcanbechangedanytimeifneeded.

USER ENTRY CODE1. Userentrycodeallowstheindividualusertolockandunlockthedeadbolt.2. Thefactorypresetuserentrycodeis1-2-3-4.Pleasedeleteitandcreateyourpersonal,uniqueuser

entrycodeassoonasthedeadboltisinstalled.3. Userentrycodecanbe4-10digitsinlength.4. Maximumof6userentrycodescanbeprogrammedintoonedeadbolt.5. Anindividualuserentrycodecanbechanged/deleted/addedtothelocksetonlybyusingavalid

programmingcode.

Page 19: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.17

PROGRAMMING

AUTOMATIC BOLT DIRECTION ADJUSTMENT

Deadboltthrowdirectionisautomaticallyadjustedtoleftorright-handeddoor.

1. Deadboltshouldbeinunlockedposition.2. Makesuretheinteriorthumbturnpositionisidentifiedproperlyaccordingtodoorhanding. (seepage12).

FUNCTION STEPS

DetectLeft/RightHandDoorInstallation

EnterProgramming

Code

Press“0”

Page 20: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

18 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.

PROGRAMMING

CHANGE PROGRAMMING CODE

IMPORTANT: The factory preset programming code is 0-0-0-0 and needs to be changed to a unique6 digit number before operating the deadbolt.

1. Deadboltshouldbeinunlockedposition.2. LEDindicatorflashes“Orange”whileinprogrammingmode.LEDindicatorflashes“Green”twice

with2long“Beeps”whenprogrammingfunctionisperformedcorrectly.LEDindicatorlightflashesthreetimeswiththree“Beeps”whenprogrammingfunctionisperformedincorrectly.

Note: wait for at least 6 seconds or press and repeat programming steps if programming error was committed.

3. Everyprogrammingstepshouldbeperformedin6secondsorless.

FUNCTION STEPSChange

ProgrammingCode

EnterProgramming

Code

Press“4”

EnterProgramming

Code

Page 21: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.19

PROGRAMMING

ADD/DELETE USER ENTRY CODE

1. Userentrycodescanbedeletedindividually.Youcanreusethesamenumberasacodeevenifitwasdeletedbefore.

2. Thefactorypresetuserentrycodeis1-2-3-4.Pleasedeleteitandcreateyourpersonaluniqueuserentrycodeoncethedeadboltisinstalled.

FUNCTION STEPS

AddNewUserEntryCode

EnterProgramming

Code

Press“1”

EnterNewUserEntry

Code

DeleteExistingUserEntryCode

EnterProgramming

Code

Press“2”

EnterUserEntryCodeyouwanttodelete

Page 22: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

20 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.

PROGRAMMING

DELETE ALL USER ENTRY CODES AT ONCE

1. Alluserentrycodescanbedeletedatonce.Youcanstillreusethesamenumbersasnewcodeseveniftheyhavebeendeletedbefore.

2. “Auto-Lock”and“KeypadLock”functionswillbeinvalidafterdeletingalluserentryuserentrycodes,andthedeadboltcanonlybeoperatedbyregularkey.Thefunctionswillberestoredwhenthenewuserentrycodesarecreated.

FUNCTION STEPS

DeleteallUserEntryCodesatonce

EnterProgramming

Code

Press“3”

Page 23: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.21

PROGRAMMING

TEMPORARILY DISABLE ALL USER CODES

1. “Auto-Lock”and“KeypadLock”functionswillbeinvalidwhenalluserentrycodesaretemporarilydisabled.Thedeadboltcanonlybeoperatedbyregularkeyatthistime.

2. Repeattheprogrammingstepstorestorealluserentrycodes.

FUNCTION STEPS

Disable/EnableallUserEntryCodes

EnterProgramming

Code

Press“8”

Page 24: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

22 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.

PROGRAMMING

CREATE A DISPOSABLE USER ENTRY CODE

1. Disposableentrycodecanonlybeusedonce.2. Youcanreusethesamenumberasadisposableuserentrycodeagain.

FUNCTION STEPSCreate

DisposableUserEntryCode

EnterProgramming

Code

Press“9”

EnterNewDisposableEntrlyCode

Page 25: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.23

PROGRAMMING

“AUTO-LOCK” FUNCTION

1. Thedoorwillbeautomaticallylockedwithin10to99secondswhen“Auto-Lock”functionisenabled.2. Thedeadboltcomeswith“Auto-Lock”functiondisabledfromthefactory.3. “Auto-Lock”timedelayispresetto30seconds.Itcanbeadjustedto10to99secondsifneeded.4. Thesystemwillsignalanoperatingerrorifthedeadboltfailstolatchproperly.Re-entervaliduser

entrycodetounlockthedoorandretractthelatchbolt.“Auto-Lock”functionisnowrestored.

FUNCTION STEPS

Auto-LockON/OFF

EnterProgramming

Code

Press“5”

Auto-LockTimeDelay

EnterProgramming

Code

Press“6”

EnterSeconds(10to99)

Page 26: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

24 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.

PROGRAMMING

MUTE ON/OFF

1. Audible“Beep”alertswhenpressingkeypadbuttons,duringprogrammingoroperatingerrors,canbeturnedoffifneeded.

2. LEDindicatorlightwillstillfunctionwhenmuted.3. Motoroperatingsoundcannotbemuted.

FUNCTION STEPS

MuteON/OFF

EnterProgramming

Code

Press“7”

Page 27: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.25

PROGRAMMING

RESTORE FACTORY SETTING

1. Removebatterycoverandlocate“R”button.2. Press“R”buttonforatleast5secondsuntilyouhearthreelong“Beeps”.3. Thedeadboltisnowresetbacktothefactorysetting: -programmingcode0-0-0-0 -userentrycode1-2-3-44. Repeatautomaticboltdirectionadjustment(seepage17)beforeyouproceedtoprogrammingany

otherfunctinintothedeadbolt.

Page 28: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

26 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.

OPERATION

LOCK OPERATION

TO LOCK1. Press oruseregularkeytolockthedeadboltfromoutside.2. Turnthumbturnpiecetolockthedeadboltfrominside.

TO UNLOCK1. Entervaliduserentrycodeandpress ,oruseregularkeytounlockthedeadboltfromthe

outside.2. Turnthumbturnpiecetounlockthedeadboltfromtheinside.

Page 29: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.27

OPERATION

SECURITY MODE

1. Thekeypadwillbeautomaticallydeactivatedfor45secondsafter5unauthorizedentryattempts.2. Thedeadboltcanbelockedandunlockedbytheregularkeyundersecuritymode.

Page 30: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

28 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.

QUESTIONS ANSWERS

A.I’mnotabletochangetheprogrammingcode.

1.Makesurethateveryprogrammingstepiscompletedinunder6seconds.

B.Whattypeofbatteriesdoyourecommend?

1.Forbestresults,pleaseusenewnon-rechargeablealkalinebatter-ies.(4-AA1.5V)

C.Howlongwillthelockoperateononesetofbatteries?

1.Basedon15operationsperday,asinglesetofalkalinebatterieswilloperatethelocksetforoverayear.

TROUBLESHOOTING GUIDE - INSTALLATION

QUESTIONS ANSWERS

A.Ijustcompletedtheinstallation,butamunabletooperateitmanually.WhatshouldIdo?

1.Checkthealignmentbetweenthestrikeholeandthelatchtoensurethereisunobstructedmovementofthelatchbolt.

2.Makesurethetorquebladeisproperlyinsertedintothelatchhubinahorizontalposition.

3.RepeattheAutomaticBoltDirectionroutine(seepage17).

B.SometimeswhenIoperatethelock

manuallyI“feel”abumpwhileturningthethumbturnorkey.

1.Theelectromechanicalcomponentsofthelocksetareoutofsync.Tore-synchronizethesystemplease“lock”andthen“unlock”thedeadboltusingthekeypad.

C.Inampressinganybuttononthekeypadanditdoesn’tseemtorespondatall.

1.Checktoseeifthebatteriesareproperlyinstalled.2.Re-installnewbatteriesifthe“LowBatteryWarning”ison.3.CheckforproperconnectionbetweentheICwires.

Page 31: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.29

TROUBLESHOOTING GUIDE - OPERATION

QUESTIONS ANSWERS

A.I’mnotabletochangetheprogrammingcode.

1.Makesurethateveryprogrammingstepiscompletedinunder6seconds.

B.Whattypeofbatteriesdoyourecommend?

1.Forbestresults,pleaseusenewnon-rechargeablealkalinebatter-ies.(4-AA1.5V)

C.Howlongwillthelockoperateononesetofbatteries?

1.Basedon15operationsperday,asinglesetofalkalinebatterieswilloperatethelocksetforoverayear.

Page 32: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

30 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.

INFORMATION PAGE

NAME USER CODE

IMPORTANT NOTE:1. Donotshareyourprogrammingcodewithanyoneelse.2. Keepawrittencopyofallvalidusercodesinasafeplace.(Youmayusethetablebelowtorecord

yourinformation)3. Youareadvisedtore-programallcodesifyoulostanysecurityinformationinthetable.

PROGRAMMING CODE

Page 33: CONCIERGE 100 - Taymor Canada · CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE IMPORTANT SAFETY INFORMATION 1 ... Using the key, retract and extend the bolt a few

Taymor’s CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT is manufacturedunderthehigheststandardsofqualityandworkmanship.TaymorLocksarewarrantedtobefreefromfinishdefectsfor5(five)yearsandfreefrommechanical,materialandworkmanshipdefectstotheoriginalconsumerpurchaserforthelifeoftheproductaslongastheoriginalownerownshis/herhome.Taymorwillreplacefreeofcharge,duringthewarrantyperiod,anypart that fails tomeet thewarrantyundernormal installationanduseas longas theproducthasbeencaredforaccordingtothecareinstructionslistedinthepackageandonthewebsite.Electroniccomponentsofthislockarelimitedto1(one)yearfromthedateofpurchase.

Formoredetailssee www.taymor.com

CONCIERGE 100PROFESSIONAL SERIESELECTRONIC DEADBOLT

WARRANTY

®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.31