com.tom com.tom CODESYS Release Notes Important Update Notes com.tom CODESYS update packages are available at https://www.comtom.de. com.tom CODESYS v7.11.2 (20160122) Component: CoDeSys RTS (1 match) Ticket Type Summary Description Solution #1205 Defect Modbus 32 Bit types have wrong values Modbus 32 Bit types have wrong values Fixed com.tom CODESYS v7.11.1 (20150922) Component: CoDeSys Eventlog (1 match) Ticket Type Summary Description Solution #766 Defect IEC 60870 5104: Do not print an error in the Event Log if there is no license Do not print an error in the Event Log if there is no license Solved Component: CoDeSys Portal (2 matches) Ticket Type Summary Description Solution #756 Defect Portal keepalive interval from 1 to 14 accepted The form for the portal settings accepts keepalive intervals from 1 to 14 seconds although only the value 0 and values from 15 to 3600 should be accepted. The invalid values are corrected to 15 internally. #895 Defect Correct portal paths for Cellular Modem and OpenVPN Correct the portal paths for Cellular Modem and OpenVPN. Then the OpenVPN must be controllable by the Portal, if it is configured on the device's settings page Fixed Component: CoDeSys RTS (2 matches)

com.tom CODESYS Release Notes · PDF CODESYS Release Notes ... download of CODESYS program ... #694 Defect TSP BASIC 5.2 V2 must not have inputs

Embed Size (px)

Citation preview

com.tom

com.tom CODESYS Release Notes

Important Update Notes

com.tom CODESYS update packages are available at https://www.com­tom.de.

com.tom CODESYS v7.11.2 (2016­01­22)

Component: CoDeSys ­ RTS  (1 match)

Ticket Type Summary Description Solution

#1205 Defect Modbus 32 Bit types havewrong values

Modbus 32 Bit types havewrong values

Fixed

com.tom CODESYS v7.11.1 (2015­09­22)

Component: CoDeSys ­ Eventlog  (1 match)

Ticket Type Summary Description Solution

#766 Defect IEC 60870­5­104: Donot print anerror in theEvent Log ifthere is nolicense

Do not print an error in the Event Logif there is no license

Solved

Component: CoDeSys ­ Portal  (2 matches)

Ticket Type Summary Description Solution

#756 Defect Portalkeep­aliveintervalfrom 1 to14 accepted

The form for the portal settingsaccepts keep­alive intervals from 1 to14 seconds although only the value 0and values from 15 to 3600 should beaccepted. The invalid values arecorrected to 15 internally.

#895 Defect Correctportal pathsfor CellularModem andOpenVPN

Correct the portal paths for CellularModem and OpenVPN. Then theOpenVPN must be controllable by thePortal, if it is configured on thedevice's settings page

Fixed

Component: CoDeSys ­ RTS  (2 matches)

Ticket Type Summary Description Solution

#762 Enhancement Increasemaximumbytes ofinputs andoutputs

Increase maximum bytes of input andoutput to be able to hold themaximum of 768 values respectively.These inputs and outputs are declaredin the CODESYS export. It is currentlyrestricted by 0x100 = 256 bytes each.It should be restricted to 768 * 8(double) bytes each. Whereas this ispossible for the inputs, it is notpossible for the outputs, because themaximum of 64K is reached. Theoutputs are restricted to 0x600.

#770 Enhancement FTP client Create an FTP client for com.tomCODESYS.

Component: CoDeSys ­ System  (4 matches)

Ticket Type Summary Description Solution

#424 Defect Metersettings notvalidatedon scan

The Meter settings are not validatedbefore scanning. It is possible to starta scan with an invalid maximumnumber of values per device.

#667 Defect IEC 60870­5­104serverdriverallows toomanyvalues

When the IEC 60870­5­104 serverdriver checks the global I/O limit, itcounts each configured value as oneinput or output ignoring the range.

#785 Defect Many M­Busdevices andvalues timeoutdownload ofCODESYSprogram

Many M­Bus devices and values timeout download of CODESYS program ifno M­Bus devices are physicallyconnected.

#791 Defect Many M­Busdevices andvalues timeoutdownload ofCODESYSprogram ­Version 2

Many M­Bus devices and values timeout download of CODESYS program ifno M­Bus devices are physicallyconnected. (This ticket is anenhancement to #785)

Component: CoDeSys ­ Update  (2 matches)

Ticket Type Summary Description Solution

#438 Defect Falseupdateprogressindicationon website

When performing an update throughthe local website, the progressindication shows false values whileprogramming the update.

#748 Defect Factorysettings not

The com.tom CODESYS evaluates thetype of update packages wrongly. Two

updatedcorrectly

things can happen:

1.  When an update package isapplied, the factory settings willnot be updated. So when afactory reset is performed, thesettings may be wrong. Thismay also apply to internalsettings that are not visible onthe settings website, but are stillimportant for the correctfunctioning of the WEB­PLC.

2.  When a configuration package isapplied, also the factory settingswill be updated. So when afactory reset is performed, itwill not reset to the factorysettings but to the settings fromthe previous configurationpackage.

Component: CoDeSys ­ Website  (4 matches)

Ticket Type Summary Description Solution

#608 Defect Home site:Implementfloat anddouble

The home site might not be able toshow float and double values.

#663 Defect IEC 60870­5­104:"MaximumADPU Size"must belimited to253

The parameter "Maximum ADPU Size"must be limited to 253 instead of 255.Reason: The size parameter indicatesthe size of the content of an APDU.One APDU may have the size of 255bytes, including the type and theparameter size which are 2 byteslong.

Also rename ADPU to APDU.#706 Defect @CHIPTOOL

messagesshown inevent log

Sometimes the event log containsmessages that look similar to theoutput of the @CHIPTOOL (IPaddresses, device names etc.)

#786 Defect Scope anduser namecan containunderscoreand periodcharactersin portalsettings

In the portal settings it should beallowed to include underscores andperiods in the scope and user namefields. Note that neither the scope northe user name must start or end withan underscore or period.

com.tom CODESYS v7.6.0 (2015­02­06)

Component: CoDeSys ­ Eventlog  (1 match)

Ticket Type Summary Description Solution

#692 Defect Cellular modemdriver's "Dataconnection broken"message shows wrongvalues

When the cellular modemdriver emits the message"Data connection broken...",the values for the DCD pinand the PPP status may bewrong.

Component: CoDeSys ­ Portal  (2 matches)

Ticket Type Summary Description Solution

#646 Enhancement Use Kolibri instead ofiCex

The com.tom CODESYSshould use the Kolibri Portalinstead of the iCex Portal.

#701 Enhancement Application namevisible in Kolibri

Make the application nameset by the methodcomtomSetApplicaionNamein CODESYS appear in theKolibri portal.

Component: CoDeSys ­ System  (8 matches)

Ticket Type Summary Description Solution

#307 Enhancement Support com.tom M­BUS 5.2 V1 and V2

Support the target com.tomM­BUS 5.2 V1 and V2.

#655 Defect 'Swap words'checkbox in ModbusMaster value dialognot correctlyenabled/disabled

In the value dialog of theModbus Masterconfiguration form, the'Swap words' checkbox isnot correctly enabled anddisabled depending on theselected data type.

#657 Defect IEC 60870­5­104:Slow response uponmany fast commands

The IEC 60870­5­104 stackresponses slowly when itreceives many commandsin a short time.

#666 Defect gm_getTrafficCountersmakes the deviceunreachable

The functiongm_getTrafficCounters inthe CODESYS librarygm_comtom.lib crashes thedevice.

Solved

#674 Enhancement IEC 60870­5­104: Addactivation terminationfor pulse commands

The pulse commands mustbe handled inside theserver library, and the endof a pulse must be indicatedby a call to a new callback.With this, the client can beinformed by the serverabout the positive/negativetermination of anactivation.

Solved

#700 Enhancement Support second serialport

Support a second physicalserial port in CODESYS.

Solved

#722 Defect OpenVPN server withport number >32767

The OpenVPN does not workwith servers that use a port

Solved

does not work number higher than 32767.The message "OpenVPNDriver: Options error: Badport number: <portnumber>" is logged.

#734 Defect Reboot after enablingthe PFI in Chip.ini

The device must berebooted after enabling thePFI in Chip.ini for thechange to take effect.

Solved

Component: CoDeSys ­ TSP  (2 matches)

Ticket Type Summary Description Solution

#255 Enhancement New Image/Picture forTSPs

Show correct image/pictureat the configuration of atarget in CoDeSys.

#694 Defect TSP BASIC 5.2 V2must not have inputsand outputs in its PLCconfiguration

TSP BASIC 5.2 V2 must nothave inputs and outputs inits PLC configuration,because they are located inthe CODESYS export filedownload.

Component: CoDeSys ­ Website  (3 matches)

Ticket Type Summary Description Solution

#411 Defect Cannot set Modbusunit identifier to 0

When configuring a ModbusTCP value, the unitidentifier cannot be set to0. It will be automaticallychanged to 255.

#450 Enhancement Upload file forOpenVPN's ­­auth­user­pass option

The OpenVPN configurationwebsite should allow toupload a file containing username and password asdesired by the ­­auth­user­pass option.

#545 Enhancement Explicitly start updateafter download

Downloading and applyingthe update package shouldbe started separately forremote updates. So theuser can make sure that alldevices have successfullydownloaded the package,before the update isapplied.

com.tom CODESYS v5.11 (2014­10­08)

Component: CoDeSys ­ Cellmodem  (3 matches)

Ticket Type Summary Description Solution

#389 Enhancement Wait longer for cellular The cellular modem driver Solved

network registration should wait longer fornetwork registration.Currently the driver abortsafter three minutes. Itshould wait up to 15minutes.

#408 Defect Error "Invalid PIN orSIM card locked" evenif PIN was correct

Solved

#642 Defect Cellular modem drivermay hang if themodem hangs whilereceiving a shortmessage

If the cellular modemhangs and does not replyany more while the cellularmodem driver tries toreceive a short message,the cellular modem drivermay hang, too. The modemwill not be restarted in thiscase.

Solved

Component: CoDeSys ­ OpenVPN  (2 matches)

Ticket Type Summary Description Solution

#112 Defect OpenVPN and DHCPdoes not work

For an openVPN bridgednetwork DHCP is notworking.

#433 Defect Memory leak inOpenVPN

OpenVPN consumesmemory when key are re­negotiated. Stopping theOpenVPN driver releasesthe memory.

Component: CoDeSys ­ Portal  (3 matches)

Ticket Type Summary Description Solution

#355 Defect IcexControllerStatisticsshows suspiciousresults

The functionicexControllerGetStatisticsin com.tom.lib forCODESYS shows strangeresults.

#574 Defect IEC 60870­5­104cannot send TestFrames

IEC 60870­5­104 cannotsend Test Frames.

#575 Defect IEC 60870­5­104 uses100% CPU loadwithout a StartDT

If no StartDT (start datatransfer) is sent by the IEC60870­5­104 client after aconnection establishment,the IEC 60870­5­104 libraryuses 100% CPU load.

Component: CoDeSys ­ RTS  (8 matches)

Ticket Type Summary Description Solution

#199 Enhancement Event log messagesdocumentation

The online documentationshould include information

on event log messages.

on event log messages.#200 Enhancement GPS support com.tom CODESYS should

support GPS. Thecoordinates should betransmitted to the PORTAL.The values of GPS must beaccessible by a CODESYSprogram.

#204 Enhancement More settings forModbus values

When defining Modbusvalue, it should be possibleto:

Select the target datatypeRead more than 32bits at once (arrays)Swap the words of a32­bit or 64­bit valueDefine the unitidentifier for TCP/RTUbridges

#473 Defect Crash on CODESYSprogram download orreset

The device sometimescrashes and reboots upon aCODESYS programdownload.

Solved in[3103].

#476 Enhancement Modbus quantity mustbe considered in theCODESYS export

The attribute quantity ofModbus must be consideredin the CODESYS export. Itcan lead to having arrays.

Solved

#550 Enhancement Sort event logdescending

It should be possible toselect whether the eventlog is sorted ascending ordescending. Descendingshould be the default. Sothe latest messages willshow up at the top of thelist.

#581 Enhancement Enable altering theCODESYScommunication port

The CODESYScommunication port is incode set to 1200. Enablechanging it in configurationfile.

#637 Defect IEC 60870­5­104:Server only accepts S­Frames foracknowledgement

Server closes connectionwhen there is noSupervisory frame AND kis reached AND some(unknown) combination ofthe timeouts is reached.The server expects asupervisory frame (S­Frame) as anacknowledgement for thesent data (I­Frames). Thisis wrong. The server shouldalso accept I­Frames withthe contained Receive­Sequence­Number as anacknowledgement. Theacknowledgement of sentdata only depends on the

data only depends on theReceive­Sequence­Number.

Component: CoDeSys ­ System  (16 matches)

Ticket Type Summary Description Solution

#241 Enhancement Export b:\homedirectory

It should be optionallypossible to include thecontents of the b:\homedirectory in an exportedCUP file.

#246 Enhancement DHCP reconfiguration When the Ethernet networkinterface is configured viaDHCP and the networkcable is connected to a newnetwork, the DHCP clientshould renew theconfiguration.

#367 Enhancement Increase maximumnumber of Modbus andIEC 60870­5­104values

The maximum number ofvalues should be increasedfor Modbus and for IEC60870­5­104. There shouldbe a maximum totalnumber of values for allI/O drivers.

#375 Enhancement Support secondEthernet port (Switch)

The software shouldsupport the secondEthernet interface (ETH1),which is for example usedto integrate a switch (e.g.com.tom BASIC 5.2 S).

#379 Defect M­BUS 6.2 produceswrong CODESYSexport files

Ext03Drv produces wrongCODESYS export files. Itdefinitely affects the M­BUS 6.2 but it might alsoaffect other devices usingthe Ext03.

Solvedwith thechangeof theCODESYSexportfile.

#382 Defect IEC 60870­5­104server driver showsfalse error message

The IEC 60870­5­104server driver shows a falseerror message in the eventlog saying something like"Could not update output ataddress 1000. Error code30403, error value 0".

#396 Defect 32­bit float values notcorrectly transmittedto portal (cloned)

32­bit floating point valuesare not correctlytransmitted to the portal.

Solvedwithcom.tomlibrary4.54.

#435 Enhancement Add some more IEC60870­5­104 types

Add four IEC 60870­5­104types:

58 Single commandwith time tagCP56Time2a59 Double commandwith time tagCP56Time2a

CP56Time2a60 Regulating stepcommand with timetag CP56Time2a61 Set pointcommand,normalized valuewith time tagCP56Time2a.

#457 Defect IEC 60870­5­104: Toomany test frames sent

The library sends testframes every 200 ms if T3is greater than 229 s.

#466 Defect Bootproject does notwork with IEC 60870­5­104

This was detected with IEC60870­5­104 which did notcommunicate with a clientwhen using a bootproject.

#467 Defect Inputs show randomnumbers on homescreen

(Unused?) Inputs showrandom numbers on homescreen.

#475 Defect IEC 60870­5­104Readout interval mustbe adjustable

Make the IEC 60870­5­104Readout intervaladjustable.

Solved

#580 Defect Fix starting andstopping drivers

Fix starting and stoppingdrivers. The time and orderin which they are calleddepends on the 4possibilities to affect thestate of the CODESYSprogram: Reset Reset(cold) Reset (original) Bootproject

Solved

#597 Defect Crash when aCODESYS programruns and another isdownloaded

When a CODESYS programalready runs and anotherprogram is downloaded,the device crashes.

#605 Defect IEC 60870­5­104:Send­Sequence­Number of I­Framessometimes repeats

The Send­Sequence­Number of I­Frames sentby the IEC 60870­5­104server on the device mustalways be incremented by1. Sometimes it jumpsback to an already usednumber, when an S­Frameby the client contains alower Receive­Sequence­Number than the currentSend­Sequence­Number onthe server.

#624 Defect Modbus RTU "with RS232 CTS/RTS flowcontrol" blocks

Modbus RTU "with RS 232CTS/RTS flow control"blocks without a connecteddevice.

Component: CoDeSys ­ TSP  (1 match)

Ticket Type Summary Description Solution

#596 Defect RADIO­UMTS 7.2 mustnot have CAN libraries

The TSP for RADIO­UMTS7.2 must not have CAN

not have CAN librariesin its TSP

7.2 must not have CANlibraries as default becausethis leads to automaticallyadding them to the librariesin the CODESYS projectwhich results in a compileerror. The RADIO­UMTS 7.2has no CAN.

Component: CoDeSys ­ Update  (3 matches)

Ticket Type Summary Description Solution

#107 Defect Downloading updatepackage could fail

Update package filedownload does not workwhen web server is usethat hosts more than onedomain name with one IPaddress (is often used bypublic web spaceproviders).

Fixed.

#351 Enhancement Exported UpdatePackages only forcurrent or higherversion

Exported Update Packagesshould only be applicablefor the current or higherfirmware version.

#452 Defect Upload password notexported

When the login data isexported on one com.tomand the resulting CUP file isapplied to anothercom.tom, the password forfile upload (which isnormally kept in synch withthe normal websitepassword) is not changed.Thus you will be asked foranother password whenyou try to upload a file.

Component: CoDeSys ­ Website  (14 matches)

Ticket Type Summary Description Solution

#263 Enhancement Show I/Os on websitestart page

Show the available I/Os onthe start page of thewebsite. Like in the WEB­PLC.

#333 Enhancement Configurable numberof NAT mappings,Firewall rules anddynamic mapping TTL

The maximum number ofsimultaneous NATmappings, the maximumnumber of Firewall rulesand the time­to­live fordynamic Firewall rulesshould be configurable.

#342 Defect An identifier of justone character must beallowed for Modbusand IEC 60870­5­104

It is not possible to put inan identifier of just onecharacter for Modbus andIEC 60870­5­104.

Alreadysolvedwithcom.tom

lib 4.41#349 Enhancement Documentation of The possibility of a remote

#349 Enhancement Documentation ofremote update

The possibility of a remoteupdate via the portalshould be documented inthe online help.

#395 Enhancement Show portal round­triptime on home pageand portal

The minimum, maximumand average round­triptime of the portalcommunication should beshown on the home pageand on the portal. It canhelp to determine thequality of the networkconnection.

#455 Enhancement No Export ofconfiguration if notenough memory

Stop Export if size ofpackage would be greaterthan available disk space

#470 Defect Request 2 times forusername andpassword in Chromebrowser

When loading the website,the username andpassword are requestedtwo times in Chromebrowser 34.0.1847.137 m.

Solved

#471 Defect Help is not shown The help on the website isnot shown

Solved

#472 Defect Settings site shows"timeout" and devicereboots

When having a CODESYSboot project and deployinga different CODESYSprogram, then loading thesettings site fails with atimeout and the devicereboots.

Solved in[3105].

#474 Defect Settings site shows"The site is loading."forever

The settings site shows"The site is loading."forever when there aremany variables in thesymbol file of CODESYS.

Solved in[3105].

#498 Enhancement Portal watchdog A portal watchdog shouldbe configurable. It wouldreboot the device if therehas been no connection tothe portal for a givenamount of time (n min.).

Solved.

#578 Defect Messages: An s in areference is notallowed

When adding or editing amessage, the input field of'Text:' does not allow an s(S is allowed).

#600 Enhancement Create "Disclaimer"text in the help site

Add legal instructions tothe com.tom help. (Createa "Disclaimer" text that willappear in the help site.)

Solved

#620 Enhancement Reboot after changingdrivers and thenCODESYS export

If the user changes adriver's configuration onthe website (Modbus, IEC60870­5­104 Server,Meter), he has to rebootthe device beforedownloading the CODESYSexport. Show a messagefor this.

com.tom CODESYS v1.92 (2014­07­07)

Component: CoDeSys ­ OpenVPN  (1 match)

Ticket Type Summary Description Solution

#570 Defect DecreaseOpenVPNpriority to thenormal valuebefore release1.80

The one task of OpenVPN, that isresponsible for RSA, was set to thehighest priority possible incom.tom CODESYS 1.80. Thiscauses all other processes to stopwhen OpenVPN is negotiating theconnection. Decrease the priority tothe low priority it had before.

Solved

Component: CoDeSys ­ Portal  (2 matches)

Ticket Type Summary Description Solution

#571 Defect IEC 60870­5­104 uses 100%CPU loadwithout aStartDT

If no StartDT (start data transfer)is sent by the IEC 60870­5­104client after a connectionestablishment, the IEC 60870­5­104library uses 100% CPU load.

Solved

#573 Defect IEC 60870­5­104 cannotsend TestFrames

IEC 60870­5­104 cannot send TestFrames.

Solved

Component: CoDeSys ­ RTS  (2 matches)

Ticket Type Summary Description Solution

#357 Defect CODESYSprogramwithout taskand as bootproject notreachable

A com.tom CODESYS with aCODESYS program that has no userdefined task and is started as aboot project is not reachable.Telnet, FTP, CODESYS login andWebsite cannot establish aconnection. The com.tom must bereset with the reset button.

Solved

#522 Enhancement Enable alteringthe CODESYScommunicationport

The CODESYS communication portis in code set to 1200. Enablechanging it in configuration file.

Solved

Component: CoDeSys ­ SNTP  (2 matches)

Ticket Type Summary Description Solution

#404 Defect Load timefrom RTC evenif SNTP is used

Load the time from Real TimeClock (RTC) before using the SNTP.Also the time is never loaded fromRTC if a not­working SNTP serveris configured.

Solved

#572 Defect Load timefrom RTC even

Load the time from Real TimeClock (RTC) before using the SNTP.

Solved

if SNTP is used Also the time is never loaded fromRTC if a not­working SNTP serveris configured.

Component: CoDeSys ­ Update  (1 match)

Ticket Type Summary Description Solution

#356 Defect Update by SDcard (trunk)

Implement the update through a SDcard.

Solved

com.tom CODESYS v1.80 (2014­06­24)

Component: CoDeSys ­ OpenVPN  (3 matches)

Ticket Type Summary Description Solution

#505 Defect Memory leakin OpenVPN

OpenVPN consumes memory whenkey are re­negotiated. Stopping theOpenVPN driver releases thememory.

#507 Defect OpenVPN:Upload of auserpassword file

Support the upload of a userpassword file for OpenVPN.

Solved

#521 Enhancement IncreaseOpenVPNprioritydrastically

Set the highest priority for the taskof OpenVPN, that is responsible forRSA.

Solved

Component: CoDeSys ­ System  (1 match)

Ticket Type Summary Description Solution

#504 Defect Fix startingand stoppingdrivers

Fix starting and stopping drivers. Thetime and order in which they arecalled depends on the 4 possibilitiesto affect the state of the CODESYSprogragm: Reset Reset (cold) Reset(original) Boot project

Solved

Component: CoDeSys ­ Website  (1 match)

Ticket Type Summary Description Solution

#502 Defect Settings siteshows "Thesite isloading."forever

The settings site shows "The site isloading." forever when there aremany variables in the symbol file ofCODESYS.

Solved

Component: com.tom Library  (1 match)

Ticket Type Summary Description Solution

#503 Defect IEC104Servertimestampnot set

The sent packages don't contain thecorrect timestamp.

Solved.

com.tom CODESYS v1.64 (2014­05­19)

Component: CoDeSys ­ System  (1 match)

Ticket Type Summary Description Solution

#465 Defect Bootproject doesnot work with IEC60870­5­104

This was detected with IEC 60870­5­104 which did not communicate with aclient when using a bootproject.

com.tom CODESYS v1.59 (2014­05­15)

Component: CoDeSys ­ RTS  (1 match)

Ticket Type Summary Description Solution

#447 Defect Crash onCODESYSprogramdownload orreset

The device sometimes crashes and rebootsupon a CODESYS program download.

Component: CoDeSys ­ Website  (2 matches)

Ticket Type Summary Description Solution

#445 Defect Settings siteshows "Thesite isloading."forever

The settings site shows "The site isloading." forever when there are manyvariables in the symbol file of CODESYS.

#453 Defect Settings siteshows"timeout" anddevicereboots

When having a CODESYS boot project anddeploying a different CODESYS program,then loading the settings site fails with atimeout and the device reboots.

com.tom CODESYS v1.50 (2013­06­20)

Component: CoDeSys ­ RTS  (1 match)

Ticket Type Summary Description Solution

#285 Defect Messages: Slowing downCoDeSys­program if thereare no symbols

If there is no symboldescription available, theCoDeSys­program is sloweddown.

Component: CoDeSys ­ System  (1 match)

Component: CoDeSys ­ System  (1 match)

Ticket Type Summary Description Solution

#286 Defect Modbus, IEC104Server,M­Bus don't work

The modules Modbus,IEC104Server and M­Bus don'twork.

com.tom CODESYS v1.49 (2013­06­12)

Component: CoDeSys ­ Cellmodem  (2 matches)

Ticket Type Summary Description Solution

#166 Enhancement Showcellularmodem SIMID andtrafficcounters

The cellular modem's SIM ID andtraffic counters to the current andthe last month should bedisplayed on the home page.

implemented

#175 Enhancement SupportGM04

com.tom CODESYS shouldsupport the GM04 modem.

Fixed

Component: CoDeSys ­ RTS  (4 matches)

Ticket Type Summary Description Solution

#153 Enhancement Support forHTTPS andFTPS

It should be possible to accessthe web server via HTTPS and theFTP server via FTPS. Optionally itshould be possible to disableaccess via plain HTTP/FTP.

Fixed

#155 Enhancement RestrictCHIP.INIaccess andenableaccess tob:\home inifiles

The CoDeSys application shouldnot be able to access systemspecific CHIP.INI parameters.

#156 Enhancement Restrict filesystemaccess

The CoDeSys file system functionshould be restricted to pathB:\home.

Solved

#227 Defect Spacesreplaced byplus signson PORTAL

The com.tom CoDeSys replacesspaces by plus signs whensending text data to the PORTAL.

Fixed

Component: CoDeSys ­ System  (5 matches)

Ticket Type Summary Description Solution

#162 Enhancement Firewall The com.tom CODESYS shouldfeature a firewall

implemented

#168 Defect No morethan 2inputs

For Modbus function 2 (read inputstatus) it should be possible tocombine up to 32 values.

Fixed

allowed forone Modbusvalue

However the configuration doesnot allow more than 2 values.

#223 Enhancement Send andreceiveshortmessages

CODESYS for com.tom should beable to send and receive shortmessages.

Solved

#261 Defect CANopennotsupported

Support CANopen in com.tomCoDeSys

CANopenMode fast isnowimplemented.

#268 Defect Modbus TCPregistersscrambled

If the network connection isinterrupted shortly during aModbus TCP transaction, theresult of the current transactionmay be interpreted as the resultof the next transaction and so on,scrambling all registers.

Solved

Component: CoDeSys ­ TSP  (1 match)

Ticket Type Summary Description Solution

#262 Enhancement SupportAlarmtableand Trend inWebVisualisation

Support Alarmtable and Trend inthe Web Visualisation.

Fixed

com.tom CODESYS v1.48 (2013­05­27)

Component: CoDeSys ­ System  (3 matches)

Ticket Type Summary Description Solution

#260 Defect IEC 60870­5­104:Information ObjectAddress limited to 65535

The information object addressis limited to 65535.

Fixed

#276 Defect Firewall blocks all trafficon Ethernet with fixed IP

If a fixed IP address isconfigured on the Ethernetinterface (DHCP disabled), thefirewall will block all trafficregardless of any rules.

Fixed

#277 Defect CoDeSys BrandlabelGreyLogix v01.48 due toBug: Firewall blocks alltraffic on Ethernet withfixed IP

Cloned from #276:

If a fixed IP address isconfigured on the Ethernetinterface (DHCP disabled), thefirewall will block all trafficregardless of any rules.

com.tom CODESYS v1.46 (2013­04­24)

Component: CoDeSys ­ Cellmodem  (1 match)

Ticket Type Summary Description Solution

#193 Enhancement Make someCellmodemfunctionsaccessiblethroughCoDeSysprogram

Make the following Cellmodemfunctions accessible for a CoDeSysprogram:

activatedeactivategetStatusgetRssi

Component: CoDeSys ­ NAT  (2 matches)

Ticket Type Summary Description Solution

#190 Defect Ping blockedby NAT

When NAT is enabled it is not possibleto ping the device via the IP addressof its external interface.

Fixed.

#252 Defect NAT out ofmappingentries dueto networkbroadcasts

If there are a lot of networkbroadcasts the NAT module runs outof mapping entries although thesenetwork broadcasts should not beNATed.

Fixed

Component: CoDeSys ­ Portal  (1 match)

Ticket Type Summary Description Solution

#228 Defect Index out ofboundserror whendeletingnodes onthe PORTAL

During the synchronisation of the I/Oswith the PORTAL the com.tomCoDeSys shows an error messagesaying "Index out of bounds" in theevent log, if nodes have to be deletedon the PORTAL. Only one node will bedeleted.

Component: CoDeSys ­ RTS  (2 matches)

Ticket Type Summary Description Solution

#248 Defect Websitedoes notload afterreboottriggered byreboot­button

When triggering a reboot with thereboot­button on the website of thedevice, the reboot is executed, butthe website cannot be loadedanymore.

FixedwithRTOS1.60

#249 Defect Download ofa CoDeSys­project withM­Bus­devicestimes out

Download of a CoDeSys­project withM­Bus­devices times out if thecorresponding physical devices arenot connected to the com.tom.

Component: CoDeSys ­ System 

Last modified on 01/28/16 14:32:09

Component: CoDeSys ­ System  (2 matches)

Ticket Type Summary Description Solution

#222 Defect IEC60870­5­104 IOAlimited to1677721

The information object address (IOA)is limited to 1677721 instead of16777216 for IEC60870­5­104 values.

Fixed.

#251 Defect IEC60870­5­104 inputvalues withrandomvalues

IEC60870­5­104 input values haverandom values at start­up until aclient writes them.

Fixed

Component: CoDeSys ­ TSP  (1 match)

Ticket Type Summary Description Solution

#192 Enhancement CoDeSysTSP forcom.tomMBUS 5.2

Create a Target Support Package forthe com.tom MBUS 5.2

Component: CoDeSys ­ Update  (1 match)

Ticket Type Summary Description Solution

#247 Defect M­Busdevicedescriptionis notexported

On Export, the M­Bus configuration isnot exported.

Fixed