Compressed Air Efficiency:60 to 80% of the power of the prime mover is converted into an

unusable form of energy (HEAT)And to a lesser extent, into friction, misuse and noise

Approximately 10% gets to the

point of use!!

Page 4: Compressor -3 PDF

A typical compressed air system

Page 5: Compressor -3 PDF
Page 6: Compressor -3 PDF

Types of Air Compressors

There are three basic types of air compressors:Reciprocating (Recip)Rotary Screw (Screw) Rotary Centrifugal (Centrifugal)

These types are further defined by:the number of compression stages method of cooling (air, water, oil) drive method (motor, engine, steam, other) how they are lubricated (oil, oil-free) packaged or custom-built

Page 7: Compressor -3 PDF

Positive-Displacement Compressors –Reciprocating

A piston, driven through a crankshaft and connecting rod by an electric motor reduces the volume in the cylinder occupied by the air or gas, compressing it to a higher pressure. Single-acting compressors have a compression stroke in only one direction, while double-acting units provide a compression stroke as the piston moves in each direction. Large industrial reciprocating air compressors are double-acting and water-cooled. Multi-stage double-acting compressors are the most efficient compressors available, and are typically larger, noisier, and more costly than comparable rotary units. Reciprocating compressors are available in sizes from less than 1 hp to more than 600 hp.

Page 8: Compressor -3 PDF

Positive-Displacement Compressors -Rotary compressors

Most commonly used in sizes from about 30-200 hp. Most common type of rotary compressor is the helical twin screw-type (also known as rotary screw or helical lobe). Male and female screw-rotors mesh, trapping air, and reducing the volume of the air along the rotors to the air discharge point. Rotary screw compressors have low initial cost, compact size, low weight, and are easy to maintain. Rotary screw compressors are available in sizes from 3-600 hp and may be air- or water-cooled. Less common rotary compressors include sliding-vane, liquid-ring, and scroll-type.

Page 9: Compressor -3 PDF

Dynamic Compressors -centrifugal

These compressors raise the pressure of air or gas by imparting velocity energy and converting it to pressure energy. The centrifugal-type is the most common and is widely used for industrial compressed air. Each impeller, rotating at high speed, imparts primarily radial flow to the air or gas which then passes through a volute or diffuser to convert the residual velocity energy to pressure energy. Some large manufacturing plants use centrifugal compressors for general plant air, and, in some cases, plants use other compressor types to accommodate demand load swings while the centrifugal compressors handle the base load.

Page 10: Compressor -3 PDF

Dynamic Compressors –Axial and mixed flow

Axial compressors consist of a rotor with multiple rows of blades and a matching stator with rows of stationary vanes. The rotating blades impart velocity energy, primarily in an axial plane. The stationary vanes then act as a diffuser to convert the residual velocity energy into pressure energy. This type of compressor is restricted to very high flow capacities and generally has a relatively high compression efficiency. Mixed flow compressors have impellers and rotors which combine the characteristics of both axial and centrifugal compressors.

Page 11: Compressor -3 PDF

General Selection Criteria for Compressors

Capacity (m3/h) Pressure (bar) Type of Compressor

From To From To

Roots power compressor single stage

100 30000 0.1 1

Reciprocating - Single / Two stage 100 12000 0.8 12 - Multi stage 100 12000 12.0 700 Screw - Single stage 100 2400 0.8 13 - Two stage 100 2200 0.8 24 Centrifugal 600 300000 0.1 450

Page 12: Compressor -3 PDF

SYSTEM COMPONENTSIntake Air Filters : Prevent dust and atmospheric impurities from entering compressor. Dust causes sticking valves, scored cylinders, excessive wear etc.Inter-stage Coolers : Reduce the temperature of the air (gas) before it enters the next stage to reduce the work of compression and increase efficiency. They can be water-or air-cooled.After Coolers : Reduce the temperature of the discharge air, and thereby reduce the moisture carrying capacity of air.Air-dryers : Air dryers are used to remove moisture, as air for instrument and pneumatic equipment needs to be relatively free of any moisture. The moisture is removed by suing adsorbents or refrigerant dryers, or state of the art heatless dryers.Moisture Traps : Air traps are used for removal of moisture in the compressed air distribution lines. They resemble steam traps wherein the air is trapped and moisture is removed.Receivers : Depending on the system requirements, one or more air receivers are generally provided to reduce output pulsations andpressure variations.

Page 13: Compressor -3 PDF

DryersWhen air leaves an aftercooler and moisture separator, it is typically saturated. Any further radiant cooling as it passes through the distribution piping, which may be exposed to colder temperatures, will cause further condensation of moisture with detrimental effects such as corrosion and contamination of point-of-use processes. This problem can be avoided by the proper use of compressed air dryers. The most common types are:

Refrigerant-type dryers cool the air to 35 to 40F and then remove the condensed moisture before the air is reheated and dischargedDeliquescent-type dryers use a hygroscopic desiccant material with a high affinity for water. The desiccant absorbs water vapor and is dissolved in the liquid formed. Dew point suppression of 15 to 50F degrees can be expected when the proper bed level is maintainedTwin tower regenerative-type dryers use a desiccant which adsorbs water vapor in the air stream. Adsorb means that the moisture adheres to the desiccant, collecting in the thousands of small pores within each desiccant bead. The composition of the desiccant is not changed and the moisture can be driven off in a regeneration process by applying dry purge air, by the application of heat, or a combination of both. Regenerative desiccant-type dryers typically are of twin tower construction. One tower dries the air from the compressor while the desiccant in the other tower is being regenerated, after the pressure in the tower being regenerated has been reduced to atmospheric pressure. The purge air requirement can range from 10 to 18% of the total air flow, depending on the type of dryer. The typical regenerative desiccant dryer at 100 psig has a pressure dew point rating of -20F to -40F

Page 14: Compressor -3 PDF

Air ReceiverReceivers are used to provide compressed air storage capacity to meet peak demand events and help control system pressure. Receivers are especially effective for systems with widely varying compressed air flow requirements. Where peaks are intermittent, a large air receiver may allow a smaller air compressor to be used and can allow the capacity control system to operate more effectively and improve system efficiency. An air receiver after a reciprocating air compressor can provide dampening of pressure pulsations, radiant cooling, and collection of condensate. Demand-side control will optimize the benefit of the air receiver storage volume by stabilizing system header pressure and "flattening" the load peaks.

Page 15: Compressor -3 PDF

Heat Recovery with Water-CooledCompressors

Heat recovery for space heating is not as common with water-cooled compressors because an extra stage of heat exchange is required and the temperature of the available heat is lower. Since many water-cooled compressors are quite large, however, heat recovery for space heating can be an attractive opportunity. Recovery efficiencies of 50-60% are typical.

Page 16: Compressor -3 PDF

Traps and DrainsAutomatic condensate drains or traps are used to prevent the loss of air through open petcocks and valves. Drain valves should allow removal of condensate but not compressed air. Two types of traps are common: mechanical and electrical. Mechanical traps link float devices to open valves when condensate rises to a preset level. Electric solenoid drain valves operate on a preset time cycle, but may open even when condensate is not present. Other electrical devices sense liquid level and open to drain only when condensate is present. Improperly operating or maintained traps can create excessive air usage and waste energy

Page 17: Compressor -3 PDF

Air Distribution SystemsThe air distribution system links the various components of the compressed air system to deliver air to the points of use with minimal pressure loss. The specific configuration of a distribution system depends on the needs of the individual plant, but frequently consists of an extended network of main lines, branch lines, valves, and air hoses. The length of the network should be kept to a minimum to reduce pressure drop. Air distribution piping should be large enough in diameter to minimize pressure drop. A loop system is generally recommended, with all piping sloped to accessible drop legs and drain points.

When designing an air distribution system layout, it is best to place the air compressor and its related accessories where temperature inside the plant is the lowest. A projection of future demands and tie-ins to the existing distribution system should also be considered.

Page 18: Compressor -3 PDF

Reciprocating compressor

Page 19: Compressor -3 PDF
Page 20: Compressor -3 PDF
Page 21: Compressor -3 PDF
Page 22: Compressor -3 PDF

Screw compressor

Page 23: Compressor -3 PDF

Centrifugal Compressor

Page 24: Compressor -3 PDF

Compressor efficiency

( )( ) ( ) ⎥⎦

⎤⎢⎣

⎡⎟⎠⎞

⎜⎝⎛× 1 - P

P 0.612 / P Q 1-KNK / NK1-K

s

dsTheoretical kW =

N = No. of stagesK = Ratio of specific heats (1.35 for air)Ps = suction pressure in kg/cm2

Pd = Discharge pressure in kg/cm2

Q = Actual air flow (m3/min.)Actual kW = √ 3 V I × PF as measured

Efficiency of compressor and motor combination = kWActual

kW lTheoretica100 ×

Page 25: Compressor -3 PDF

Energy Efficiency practices in compressed air systems

Page 26: Compressor -3 PDF

Effect of Intake Air temperature on Power Consumption

Inlet Temperature (0C)

Relative Air Delivery (%)

Power Saved (%)

10.0 102.0 + 1.4 15.5 100.0 Nil 21.1 98.1 - 1.3 26.6 96.3 - 2.5 32.2 94.1 - 4.0 37.7 92.8 - 5.0 43.3 91.2 - 5.8

Every 40C rise in inlet air temperature results in a higher energy consumption by 1 % to achieve equivalent output. Hence, cool air intake leads to a more efficient compression.

Page 27: Compressor -3 PDF

pAir Inlet Filter on Power

Consumption

Pressure Drop Across air filter

(mmWC)

Increase in Power Consumption (%)

0 0 200 1.6 400 3.2 600 4.7 800 7.0

For every 25 mbar pressure lost at the inlet due to choked filters, the compressor performance is reduced by about 2 percent.

Page 28: Compressor -3 PDF

ElevationPercentage Relative

Volumetric Efficiency Compared with Sea Level

Altitude Meters

Barometric Pressure

Mbar At 4 bar At 7 bar

Sea level 1013 100.0 100.0 500 945 98.7 97.7

1000 894 97.0 95.2 1500 840 95.5 92.7 2000 789 93.9 90.0 2500 737 92.1 87.0

It is evident that compressors located at higher altitudes consume more power to achieve a particular delivery pressure than those at sea lvel, as the compression ratio is higher.

Page 29: Compressor -3 PDF

Efficacy of Inter and After Coolers

Details Imperfect Cooling

Perfect Cooling

Chilled Water Cooling

1 Stage inlet temperature 0C 21.1 21.1 21.1 2 Stage inlet temperature 0C 26.6 21.1 15.5 Capacity (m3/min) 15.5 15.6 15.7 Shaft Power (kW) 76.3 75.3 74.2 Specific energy consumption kW (m3/min)

4.9 4.8 4.7

Percent Change + 2.1 - - 2.1

It can be seen from the table that an increase of 5.50C in the inlet to the second stage results in a 2 % increase in the specific energy consumption. Use of cold water reduces power consumption.

Page 30: Compressor -3 PDF

Cooling Water Requirement

Compressor Type

Minimum quantity of Cooling Water required

for 2.85 m3/min. FAD at 7 bar (lpm)

Single-stage 3.8 Two-stage 7.6 Single-stage with after-cooler 15.1 Two-stage with after-cooler 18.9

Page 31: Compressor -3 PDF

Power Reduction through Pressure Reduction

Pressure Reduction Power Reduction (%)

From (bar) To (bar)

Single-stage

Water-cooled

Two-stage Water-cooled

Two-stage Air-

cooled

6.8 6.1 4 4 2.6

6.8 5.5 9 11 6.5

A reduction in the delivery pressure of a compressor would reduce the power consumption.

Page 32: Compressor -3 PDF

Expected Specific Power Consumption of Reciprocating Compressors (based on motor

input)

Pressure bar No. of Stages Specific Power kW/170 CMH

1 1 6.29 2 1 9.64 3 1 13.04 4 2 14.57 7 2 18.34 8 2 19.16 10 2 21.74 15 2 26.22

Page 33: Compressor -3 PDF

Energy Wastage due to Smaller Pipe Diameter

Pipe Nominal

Bore (mm)

Pressure drop (bar) per 100 meters

Equivalent power losses (kW)

40 1.80 9.5 50 0.65 3.4 65 0.22 1.2 80 0.04 0.2

100 0.02 0.1

Typical acceptable pressure drop in industrial practice is 0.3 bar in mains header at the farthest point and 0.5 bar in distribution system

Page 34: Compressor -3 PDF

Discharge of Air through Orifice

Gauge Pressure

Bar 0.5 mm 1 mm 2 mm 3 mm 5 mm 10 mm 12.5 mm

0.5 0.06 0.22 0.92 2.1 5.7 22.8 35.5 1.0 0.08 0.33 1.33 3.0 8.4 33.6 52.5 2.5 0.14 0.58 2.33 5.5 14.6 58.6 91.4 5.0 0.25 0.97 3.92 8.8 24.4 97.5 152.0 7.0 0.33 1.31 5.19 11.6 32.5 129.0 202.0

Page 35: Compressor -3 PDF

Cost of Air Leakage

Orifice Size mm

KW Wasted

* Energy Waste (Rs/Year)

0.8 0.2 8000 1.6 0.8 32000 3.1 3.0 120000 6.4 12.0 480000

* based on Rs. 5 / kWh ; 8000 operating hours; air at 7.0 bar

Page 36: Compressor -3 PDF

Heat Recovery

As noted earlier, compressing air generates heat. In fact, industrial-sized air compressors generate a substantial amount of heat that can be recovered and put to useful work. More than 80% of the electrical energy going to a compressor becomes heat. Much of this heat can be recovered and used for producing hot water or hot air.

Typical uses for recovered heat include supplemental space heating, industrial process heating, water heating, makeup air heating, and boiler makeup water preheating. Recoverable heat from a compressed air system is not, however, normally hot enough to be used to produce steam directly.

As much as 80-93% of the electrical energy used by an industrial air compressor is converted into heat. In many cases,a properly designed heat recovery unit can recover anywhere from 50-90% of this available thermal energy and put it to useful work heating air or water

Page 37: Compressor -3 PDF

Heat Recovery with Air-Cooled Rotary Screw Compressors

Air-cooled packaged rotary screw compressors are very amenable to heat recovery for space heating or other hot air uses. Ambient atmospheric air is heated by passing it across the system's aftercoolerand lubricant cooler, where it extracts heat from both the compressed air and the lubricant that is used to lubricate and cool the compressor.

Since packaged compressors are typically enclosed in cabinets and already include heat exchangers and fans, the only system modifications needed are the addition of ducting and another fan to handle the duct loading and to eliminate any back pressure on the compressor cooling fan. These heat recovery systems can be modulated with a simple thermostatically-controlled hinged vent. When heating is not required -- such as in the summer months -- the hot air can be ducted outside the building. The vent can also bethermostatically regulated to provide a constant temperature for a heated area.

Hot air can be used for space heating, industrial drying, preheating aspirated air for oil burners, or any other application requiring warm air. As a rule of thumb, approximately 50,000 Btu/hour of energy is available for each 100 cfm of capacity (at full-load). Air temperatures of 30 to 40oF above the cooling air inlet temperature can be obtained. Recovery efficiencies of 80-90% are common

Page 38: Compressor -3 PDF

Steps in simple shop-floor method for leak quantification

Shut off compressed air operated equipments (or conduct test when no equipment is using compressed air).Run the compressor to charge the system to set pressure of operationNote the sub-sequent time taken for ‘on load’ and ‘off load’cycles of the compressors. For accuracy, take ON & OFF times for 8 – 10 cycles continuously. Then calculate total ‘ON’ Time (T) and Total ‘OFF’ time (t).The system leakage is calculated as System leakage (cmm) = Q × T / (T + t)Q = Actual free air being supplied during trial, in cubic meters per minuteT = Time on load in minutest = Time unload in minutes

Page 39: Compressor -3 PDF

Leak test: exampleCompressor capacity (CMM) = 35Cut in pressure kg/SQCMG = 6.8Cut out pressure kg/SQCMG = 7.5On load kW drawn = 188 kWUnload kW drawn = 54 kWAverage ‘On-load’ time = 1.5 minutesAverage ‘Unload’ time = 10.5 minutes

Comment on leakage quantity and avoidable loss of power due to air leakages.

a) Leakage quantity (CMM) =

= 4.375 CMMb) Leakage per day = 6300 CM/dayc) Specific power for compressed air generation=

= 0.0895 kwh/m3

d) Power lost due to leakages/day = 563.85 kWh

( )( ) ( ) 35

5.105.11.5

×+

( )CMH6035kWh 188

×

Page 40: Compressor -3 PDF

Capacity Assessment in Shop-floor

Isolate the compressor along with its individual receiver being taken for test from main compressed air system by tightly closing the isolation valve or blanking it, thus closing the receiver outlet.Open water drain valve and drain out water fully and empty the receiver and the pipe line. Make sure that water trap line is tightly closed once again to start the test.Start the compressor and activate the stop watch.Note the time taken to attain the normal operational pressure P2 (in the receiver) from initial pressure P1.Calculate the capacity as per the formulae given below :

Min./NM TV

PPP

Q 3

0

12 ×−

=Actual Free air discharge

Where

P2 = Final pressure after filling (kg/cm2 a) P1 = Initial pressure (kg/cm2a) after bleeding P0 = Atmospheric Pressure (kg/cm2 a) V = Storage volume in m3 which includes receiver,

after cooler, and delivery piping T = Time take to build up pressure to P2 in minutes

Page 41: Compressor -3 PDF

ExamplePiston displacement : 16.88 CMMTheoretical compressor capacity : 14.75 CMM @ 7 kg/SQCMG Compressor rated rpm 750 : Motor rated rpm : 1445Receiver Volume : 7.79 CMAdditional hold up volume, i.e., pipe / water cooler, etc., is : 0.4974 CMTotal volume : 8.322 CMInitial pressure P1 : 0.5 Kgf / SQCMGFinal pressure P2 : 7.03 Kgf / SQCMGAtmospheric pressure P0 : 1.026Kgf/cm2A

Compressor output CMM :

( )2 1P P Total VolumeAtm. Pressure Pumpup time

− ××

( )4.021.0261

8.322 5.003.7×

×−

= 13.17 CMM

Page 42: Compressor -3 PDF

How Air Amplifiers Work

Compressed air flows through the inlet (1) into an annular chamber(2). It is then throttled through a small ring nozzle (3) at highvelocity. This primary air stream adheres to the coanda profile (4),which directs it toward the outlet. A low pressure area is createdat the center (5) inducing a high volume flow of surrounding airinto the primary air stream. The combined flow of primary andsurrounding air exhausts from the Air Amplifier in a high volume,high velocity flow.

Page 43: Compressor -3 PDF

HVAC and Refrigeration System

Page 44: Compressor -3 PDF

Ton of refrigeration

The cooling effect produced is quantified as tons of refrigeration.

1 ton of refrigeration = 3024 kCal/hr heat rejected.

Page 45: Compressor -3 PDF

Conceptual view of a chilled-water air-conditioning system

Page 46: Compressor -3 PDF

CFCs Are On The Way OutEighty percent of today’s existing chillers are centrifugal chillers that use R-11 as refrigerant. The newer, non-CFC alternative to R-11 is HCFC-123. Some centrifugal chillers use R-12; its non-CFC alternative is HFC-134a. Unitary A/C units typically use R-22, which will be phased out in the future.

Phase-Out DatesRefrigerants Action

1996 R-11, R-12, R-500, HCFC-152A, CFC-114

Production of these refrigerants is stopped. Equipment using these refrigerants is no longer manufactured.

2010HCFC-22 Manufacture of equipment using this refrigerant is stopped.

2020HCFC-22 Production of this refrigerant is stopped.

2020HCFC-123 Manufacture of equipment using this refrigerant is stopped.

2030HCFC-123 Production of this refrigerant is stopped.

Page 47: Compressor -3 PDF

Introduction

Refrigeration deals with the transfer of heat from a low temperature level at the heat source to a high temperature level at the heat sink.

Air conditioning for comfortRefrigeration for process

Page 48: Compressor -3 PDF
Page 49: Compressor -3 PDF

Vapour compression System

Page 50: Compressor -3 PDF

How do the chillers work ?

1. Boiling point of the water is a function of pressure. At atmospheric pressure water boils at 100 deg. C. When maintained at high vacuum, water will boil and subcool itself. The boiling point of the water at 6 mmHg (abs) is 3.7 deg. C.

Page 51: Compressor -3 PDF

2. Lithium Bromide (LiBr) has the property to absorb water due to its chemical affinity. At higher concentration and lower temperature LiBr absorbs water vapour (refrigerant vapour) very effectively.

How do the chillers work ?

Page 52: Compressor -3 PDF

3. As Lithium Bromide becomes dilute it loses its capacity to absorb water vapour. It thus needs to bereconcentrated using a heat source. Heat source may be Steam or Flue gases or even Hot water.

How do the chillers work ?

Page 53: Compressor -3 PDF
Page 54: Compressor -3 PDF
Page 55: Compressor -3 PDF

Vapour absorption chillers: Types

Single effect steam fired (0.4 to 2 kg/cm2)Steam Consumption for 200 TR = 8.5 Kg/hr/TR

Double effect steam fired (3 to 9 kg/cm2)Steam Consumption for 200 TR = 4.5 Kg/hr/TR Cost of m/c = Rs. 12000 to 15000 per TR

Low temperature hot water fired (75 – 100oC)High temperature hot water fired (110 – 145oC)Direct fired (oil, gas, kerosene)

HSD/LDO Consumption = 0.313 lit/hr/TRKerosene Consumption =0.326lit/hr/TRCost of m/c = Rs. 20,000 to 25000 per TR

Page 56: Compressor -3 PDF

Properties of Commonly used Refrigerants

Enthalpy * Refrigerant

Boiling Point

** (oC)

Freezing Point (oC)

Vapor Pressure * (kPa)

Vapor Volume * (m3 / Kg)

Liquid (kJ / Kg)

Vapor (kJ / Kg)

R - 11 23.82 -111.0 25.73 0.61170 191.40 385.43

R - 12 -29.79 -158.0 219.28 0.07702 190.72 347.96

R - 22 -40.76 -160.0 354.74 0.06513 188.55 400.83

R - 502 -45.40 --- 414.30 0.04234 188.87 342.31

R - 7 (Ammonia)

-33.30 -77.7 289.93 0.41949 -808.71 487.76

Page 57: Compressor -3 PDF

COP = (H2-H1)/(H3-H2)

Page 58: Compressor -3 PDF

Performance Assessment

The specific power consumption kW/TR is a useful indicator of the performance of refrigeration system. By messing refrigeration duty performed in TR and the Kilo Watt inputs measured, kW/TR is used as a reference energy performance indicator.

The refrigeration TR is assessed as TR = Q ⋅Cp ⋅ (Ti – To) / 3024

Where TR is cooling TR duty Q is mass flow rate of coolant in kg/hr Cp is coolant specific heat in kCal /kg / 0C Ti is inlet. Temperature of coolant to evaporator (chiller) in 0C.To is outlet temperature of coolant from evaporator (chiller) in 0C.

Page 59: Compressor -3 PDF

Overall energy consumption

Compressor kWChilled water pump kWCondenser water pump kWCooling tower fan kW

Overall kW/TR = sum of all above kW/ TR

Page 60: Compressor -3 PDF

Effect of Variation in Evaporator Temperature on Compressor Power Consumption

Evaporator Temperature

(0C)

Refrigeration Capacity

(tons)

Specific Power

Consumption

Increase in kW/ton (%)

5.0 67.58 0.81 - 0.0 56.07 0.94 16.0 -5.0 45.98 1.08 33.0

-10.0 37.20 1.25 54.0 -20.0 23.12 1.67 106.0

A 10C raise in evaporator temperature can help to save almost 3 % on power consumption.

Page 61: Compressor -3 PDF

Condenser Temperature on Compressor Power Consumption

Condensing Temperature

(0C)

Refrigeration Capacity

(tons)

Specific Power

Consumption

Increase in kW/TR

(%)

26.7 31.5 1.17 -

35.0 21.4 1.27 8.5

40.0 20.0 1.41 20.5

Page 62: Compressor -3 PDF

Effect of Poor Maintenance on Compressor Power Consumption

Condition Evap. Temp (0C)

Cond. Temp (0C)

Refrigeration Capacity

(tons)

Specific Power

Consumption (kW/ton)

Increase in

kW/Ton (%)

Normal 7.2 40.5 17.0 0.69 - Dirty condenser

7.2 46.1 15.6 0.84 20.4

Dirty evaporator

1.7 40.5 13.8 0.82 18.3

Dirty condenser and evaporator

1.7 46.1 12.7 0.96 38.7

Page 63: Compressor -3 PDF

ENERGY SAVINGS OPPORTUNITIES

Cold InsulationBuilding EnvelopBuilding Heat LoadsProcess Heat Loads Minimisation

Flow optimization and Heat transfer area increase to accept higher temperature coolantAvoiding wastages like heat gains, loss of chilled water, idle flowsFrequent cleaning / de-scaling of all heat exchangers

Page 64: Compressor -3 PDF

At the Refrigeration A/C Plant Area

Ensure regular maintenance of all A/C plant components as per manufacturer guidelines.Ensure adequacy of chilled water and cooling water flows, avoidance of bypass flows by valving off the idle equipment.Minimize part load operations by matching loads and plant capacity on line, adopting variable speed drives for varying process load. Ensure efforts to continuously optimize condenser and evaporator parameters for minimizing specific energy consumption and maximizing capacity.Adopt VAR system where economics permit as a non CFC solution

Page 65: Compressor -3 PDF

Select the right Cooling Medium

Type of cooling Power Consumption

1. Cooling tower water 0.1 KW/TR2. Chilled water System at 10oC 0.7 KW/TR3. Brine System at -20oC 1.8 KW/TR

Order of preferenceCooling water ChilledWater Brine

Page 66: Compressor -3 PDF

Energy Savings in Refrigeration systems

There are two broad ways by which energy can be conserved

1.By decreasing the load

2.By optimising the refrigeration system

Page 67: Compressor -3 PDF

Calculating the operating load of a chiller plant

Refrigerationplant

Refrigerationplant

Hot well12OC

Cold well8OC

Process

Chilled water flow – 100 m3/hr

Refrigeration TR - 100,000 kg/hr x 1 x 43000

m Cp ∆Τ

- 133.33 TR

Power drawn by compressor, kWEfficiency -

TR

120 - = 0.9

133.33

Page 68: Compressor -3 PDF

Energy saving measures in A/c System

Comfort conditions: 25OC, 55 % RHMinimize heat load through glass windows

Provide sun control film, Use double glassInsulate roof top in A/C Building

Provide under deck insulation of 50 mm, Provide lawns at roof topOptimize fresh air supply into a/c room

Conduct CO2 study to optimize fresh air quantity10-15 cfm/person or 0.25 cfm/sq..ft as per ASHRAE

Minimise artificial lightingUse natural lighting , 3.5 kw lighting consumes 1.0 TR load

Provide controlsinstall thermostat to control peak and base loadProvide VSD for AHU with return air temp.sensor-set at 25oC

Air tight the building envelopprevent cold air leakage, Provide door closures

Avoid heat producing equipments inside the roomkeep away UPS Battery , ovens, other loads

Page 69: Compressor -3 PDF

Efficient operation & maintenance

The suction Temperature, pressure delivery pressure of compressors should be kept at optimum level

Ensure all indicators are working properlyKeep record of oil consumption

CondensersRemove scale and algae and adopt suitable water treatmentGive periodic purging of non-condensable gasesLesser the water temperature more the COPRoutine defrosting of Cooling coils Stop condenser water pump when compressor not working 5OC rise in condensing temperature increases 10 % power consumption5OC rise in evaporating temperature increases 10 % power consumption

Page 70: Compressor -3 PDF

Energy saving measures in refrigeration

Look for process modifications to reduce the cooling loadUse cooling water to remove the maximum heat before using chilled waterProvide VSD for condenser water pumps

to vary the cooling water flow to maintain 4oC difference across the condensersAvoid primary pump operation

Normally two pumps are operation(Chilled water supply pump from cold well and return water pump from hot well)Modify to operate only return water pumpProvide VSD for efficient part load operation

Explore ‘Ice-bank’ system for Maximum demand reductionExplore application of vapour absorption with cost economicsReplace old systems with modern energy efficient systems

Page 71: Compressor -3 PDF

Cold InsulationDifference in temperature between ambient and surface

Heat ingressKcal/m2/hr

Exposed area per tonne of refrigeration

5 35 86

10 73 41

15 113 27

20 154 19

Basis: Ambient temperature - 35OC, emissivity – 0.8, still air conditionsAllowable heat ingress – 10 –15 Kcal/m2/hr

Thumb rules for cold InsulationChilled water pipe insulation (Provide 2 to 3 inch thickness) Duct insulation (Provide 1 to 2 inch thickness) Suction line refrigerant pipe insulation(Provide 2 to3 inch thickness)

Page 72: Compressor -3 PDF

End

Page 73: Compressor -3 PDF

Fans and Blowers

Page 74: Compressor -3 PDF

Difference between fans, blowers and compressors

Equipment Specific Ratio Pressure rise (mmWg)

Fans Up to 1.11 1136

Blowers 1.11 to 1.20 1136 – 2066

Compressors more than 1.20 -

As per ASME the specific pressure, i.e, the ratio of the discharge pressure over the suction pressure is used for defining the fans, blowers and compressors as highlighted below :

Page 75: Compressor -3 PDF

Typical centrifugal fan operation

Page 76: Compressor -3 PDF

Fan types

Axial fanCentrifugal fan

Page 77: Compressor -3 PDF

Centrifugal Fan: Types

Backward CurvedPaddle Blade (Radial blade)

Forward Curved (Multi vane)

Page 78: Compressor -3 PDF

Axial Flow Fan: TypesTube Axial

Vane Axial

Propeller

Page 79: Compressor -3 PDF

Fan Types and Efficiencies

Centrifugal Fans Peak Efficiency Range

Airfoil, backwardly curved/inclined 79-83 Modified radial 72-79 Redial 69-75 Pressure blower 58-68 Forwardly curved 60-65 Axial fan vanaxial 78-85 Tubeaxial 67-72 Propeller 45-50

Page 80: Compressor -3 PDF

Axial-flow Fans Centrifugal Fans

Type Characteristics Typical Applications Type Characteristics Typical

Applications

Propeller

Low pressure, high flow, low efficiency, peak efficiency close to point of free air delivery

Air-circulation, ventilation, exhaust

Radial High pressure, medium flow, efficiency close to tube-axial fans, power increases continuously

Various industrial applications, suitable for dust laden, moist air/gases

Tube-axial

Medium pressure, high flow, higher efficiency than propeller type, dip in pressure-flow curve before peak pressure point.

HVAC, drying ovens, exhaust systems

Forward-curved blades

Medium pressure, high flow, dip in pressure curve, efficiency higher than radial fans, power rises continuously

Low pressure HVAC, packaged units, suitable for clean and dust laden air / gases

Vane-axial

High pressure, medium flow, dip in pressure-flow curve, use of guide vanes improves efficiency

High pressure applications including HVAC systems, exhausts

Backward curved blades

High pressure, high flow, high efficiency, power reduces as flow increases beyond point of highest efficiency

HVAC, various industrial applications, forced draft fans, etc.

Airfoil type Same as backward curved type, highest efficiency

Same as backward curved, but for clean air applications

Page 81: Compressor -3 PDF

System characteristic curve

Page 82: Compressor -3 PDF
Page 83: Compressor -3 PDF

System curve

Page 84: Compressor -3 PDF

Fan Laws

Flow ? Speed Pressure ? (Speed)2 Power ? (Speed)3

1 1

2 2

Q NQ N

= 2

1 1

2 2

SP NSP N

⎛ ⎞= ⎜ ⎟⎝ ⎠

3

1 1

2 2

kW NkW N

⎛ ⎞= ⎜ ⎟⎝ ⎠

Varying the RPM by 10% decreases or increases air delivery by 10%.

Varying the RPM by 10% decreases or increases the static pressure by 19%.

Varying the RPM by 10% decreases or increases the

power requirement by 27%.

Where Q – flow, SP – Static Pressure, kW – Power and N – speed (RPM)

Page 85: Compressor -3 PDF

Fan static pressureFan Static Pressure SP = SP (Fan outlet) – SP (Fan outlet)

SP (Fan outlet) – Static pressure at fan outlet, inches WCSP (Fan outlet) – Static pressure at fan inlet, inches WC

SP = 0.05 – (-10)= 10.05 in W.C.

Page 86: Compressor -3 PDF

Static Pressure Profile of the System

Page 87: Compressor -3 PDF

Static pressure drop and rise across entire system

Fan behaviour

Page 88: Compressor -3 PDF

Speed vs Power

% Speed % Power

100

90

80

70

60

50 13

100

73

51

34

22

Page 89: Compressor -3 PDF

Flow control

Damper - Most PopularVariable Speed Drive

Recirculation

Damper 100

VFCPower 75

50

VFD25

Ideal25 50 75 100

Flow

Page 90: Compressor -3 PDF

Impact of speed reduction

Page 91: Compressor -3 PDF

Use of VSD: Boiler ID fan case study

Page 92: Compressor -3 PDF

Use of VSD: Boiler ID fan case study(contd.)

Page 93: Compressor -3 PDF

Energy audit of fan

• Collect fan and motor specifications with ducting network

• Measure motor power input• Measure fan and motor speed• Measure static pressure at various points in the

duct• Measure total and static pressure and compute

flow• Estimate the system efficiency and check fan

operating point

Page 94: Compressor -3 PDF
Page 95: Compressor -3 PDF
Page 96: Compressor -3 PDF

What to Look for in the FieldOverall system efficiency will be determined by the type of fan or blower, its interaction with the air distribution system, and the method of control.

•Determine whether the right type of fan or blower is used for an application. Is your fan or blower is providing the best efficiency and performance in a given application.

•The efficiency of a system depends on the number and type of bends and restrictions. Sharp bends, especially, increase the resistance the fan or blower must overcome. Bends and restrictions near the inlet or outlet seriously degrade capacity and efficiency.

•With a properly selected fan or blower and well-designed air distribution system, the method of control is the main thing determining energy efficiency. In systems requiring constant air volume, the speed of a belt-driven fan or blower should be adjusted by proper selection of pulley sizes, and equipment should operate only when needed. In systems requiring variable airflow, an adjustable-speed control is most efficient.

Page 97: Compressor -3 PDF

Energy conservation in fans

• Match fan capacity to demand– downsizing, pulley change, VSD..

• Avoid unnecessary demand– excess air reduction– idling

• Reduce pressure drops– Remove redundant ducts– Modify ducting with minimum bends

• Drive system – Provide direct drive where possible– Replace V-belt by flat belt

• Replace with energy efficient fans• Regular preventive maintenance

Page 98: Compressor -3 PDF

Energy saving in Boiler ID fan by speed reduction through pulley change

8”10” 26 kW

1470 RPM 1181 RPM

14 kW 6” 10”

1470 RPM 882RPM

Page 99: Compressor -3 PDF

End

Page 100: Compressor -3 PDF

Pumps and Pumping Systems

Page 101: Compressor -3 PDF

End

Page 102: Compressor -3 PDF

Energy Balance for a Typical Pumping System

ELECTRICITY100%

12% LOSS

2% LOSS

24% LOSS

9% LOSS

11% LOSS

MOTOR

COUPLING

PUMPS

VALVES

PIPES

WORK DONE ON WATER

Page 103: Compressor -3 PDF

Centrifugal pump

Page 104: Compressor -3 PDF

Static head

Page 105: Compressor -3 PDF

Friction head or Dynamic head

Page 106: Compressor -3 PDF

System with high static head

Page 107: Compressor -3 PDF

System with low static head

Page 108: Compressor -3 PDF

Pump curve

Page 109: Compressor -3 PDF

Pump operating point

Page 110: Compressor -3 PDF

Typical pump characteristic curves

Page 111: Compressor -3 PDF

Effect of Throttling

HeadMeters

82%

Pump Curve at Const. Speed

Full open valveSystem Curves

Flow (m3/hr)

Operating Points

A

500 m3/hr300 m3/hr

50 m

70 m

Static Head

42 m

Page 112: Compressor -3 PDF

Effect of Throttling

HeadMeters

Pump Efficiency 77%

82%

Pump Curve at Const. Speed

Partially closed valve

Full open valveSystem Curves

Flow (m3/hr)

Operating Points

A

B

500 m3/hr300 m3/hr

50 m

70 m

Static Head

C42 m

Page 113: Compressor -3 PDF

Centrifugal Pump Performance Chart

Page 114: Compressor -3 PDF

Efficiency Curves28.6 kW

14.8 kW

Page 115: Compressor -3 PDF

Power Requirement for PumpYou can use any of the following formulas to make your calculations:

Page 116: Compressor -3 PDF

Power calculations

Assume that we need to pump 68 m3/hr. to a 47 meter head with a pump that is 60% efficient at that point.

Liquid Power - 68 x 47 / 360 = 8.9 KwShaft Power - 8.9 / 0.60 = 14.8 KwMotor Power - 14.8 / 0.9 = 16.4 Kw

Page 117: Compressor -3 PDF

Using oversized pump !As shown in the drawing, we should be using impeller "E" to do this, but we have an oversized pump so we are using the larger impeller "A" with the pump discharge valve throttled back to 68 cubic meters per hour, giving us an actual head of 76 meters.

Now our Kilowatts look like this:

Liquid Power - 68 x 76 / 360 = 14.3 KwShaft Power - 14.3 / 0.50 = 28.6 KwMotor Power - 28.6 / 0.9 = 31.8 Kw

Page 118: Compressor -3 PDF

Losing Energy

Subtracting the amount of kilowatts we should have been using gives us:31.8 - 14.8 = 17 extra kilowatts being used to pump against the throttled discharge valve.

Extra energy used - 8760 hrs/yr x 17 = 1,48,920 kw.= Rs. 5.95 lacs/annum

In this example the extra cost of the electricity could almost equal the cost of purchasing the pump.

Page 119: Compressor -3 PDF

Flow vs Speed

If the speed of the impeller is increased from N1 to N2 rpm,the flow rate will increase from Q1 to Q2 as per the given formula:

Page 120: Compressor -3 PDF

The affinity law for a centrifugal pump with the impeller diameter held constant and the speed changed:

Flow:Flow:Q1 / Q2 = N1 / N2

Example: 100 / Q2 = 1750/3500

Q2 = 200 GPM

Page 121: Compressor -3 PDF

Head Vs speed

The head developed(H) will be proportional to the square of the quantity discharged, so that

Page 122: Compressor -3 PDF

Head:Head:

H1/H2 = (N12) / (N22) Example: 100 /H2 = 1750 2 / 3500 2

H2 = 400 Ft

Page 123: Compressor -3 PDF

Power Vs Speed

The power consumed(W) will be the product of H and Q, and, therefore

Page 124: Compressor -3 PDF

Power(kW):Power(kW):

kW1 / kW2 = (N13) / (N23) Example: 5/kW2 = 17503 / 35003

kW2 = 40

Page 125: Compressor -3 PDF

The affinity law for a centrifugal pump with the speed held constant and the impeller diameter changed:

Flow:Q1 / Q2 = D1 / D2Example: 100 / Q2 = 8/6Q2 = 75 GPM

Head:H1/H2 = (D1) x (D1) / (D2) x (D2)Example: 100 /H2 = 8 x 8 / 6 x 6H2 = 56.25 Ft

Power(kW):kW1 / kW2 = (D1) x (D1) x (D1) / (D2) x (D2) x (D2) Example: 5/kW2 = 8 x 8 x 8 / 6 x 6 x 6kW2 = 2.1

Page 126: Compressor -3 PDF

Pumps in parallel

Page 127: Compressor -3 PDF
Page 128: Compressor -3 PDF

Cooling Tower TheoryHeat is transferred from water drops to the surrounding air by the transfer of sensible and latent heat

Water Drop with Interfacial Film

Page 129: Compressor -3 PDF

How cooling tower works ?• Heat and Mass transfer• 1 kg of water on evaporation removes approximately 530

kcals of heat• The heat given up by the water falling inside the tower

equals the heat gained by the air rising through the tower• The hot water entering the tower is distributed within the

structure in a manner that exposes a very large water surface to the air passing through.

• Water distribution is accomplished by means of spray nozzles or distribution pans and by means of various types of “fill.”

• This fill increases the exposed water surface to maximize contact with the air, increasing the rate of heat transfer.

Page 130: Compressor -3 PDF
Page 131: Compressor -3 PDF

Tower Size vs Approach

Page 132: Compressor -3 PDF
Page 133: Compressor -3 PDF
Page 134: Compressor -3 PDF

Thermal Performance• Thermal performance of an evaporative tower is primarily

dependent upon the entering air wet bulb temperature (WBT) and relative humidity (RH).

• The entering WBT is an independent variable that dictates cooling tower selection.

• It is both the theoretical limit to the leaving cold water temperature and the only air parameter involved in cooling tower selection.

• The difference between the WBT and the tower leaving or cold water temperature (CWT) is called the approach temperature or the approach.

• Approach temperatures generally fall between 5 and 20 F.• The difference between the tower leaving or hot water

temperature (HWT) and the CWT is called the range• Range, heat load, and WBT also affect tower size

Page 135: Compressor -3 PDF
Page 136: Compressor -3 PDF
Page 137: Compressor -3 PDF
Page 138: Compressor -3 PDF
Page 139: Compressor -3 PDF
Page 140: Compressor -3 PDF
Page 141: Compressor -3 PDF

Water losses in cooling tower

Water losses include evaporation, drift (water entrained in discharge vapor), and blow down (water released to discard solids).

Drift losses are estimated to be between 0.1 and 0.2% of water supply.

Evaporation Loss = 0.00085 x water flow rate x (T1-T2)

Blow down Loss = Evaporation Loss/(cycles-1)

where cycles is the ratio of solids in the circulating water to thesolids in the make-up water

Total Losses = Drift Losses + Evaporation Losses + Blow down Losses

Page 142: Compressor -3 PDF

End

Page 143: Compressor -3 PDF

Lighting

SyllabusLighting System: Light source, Choice

of lighting, Luminance requirements, and Energy conservation avenues

Page 144: Compressor -3 PDF

Basic Terms in Lighting System and FeaturesLamps:Lamp is equipment, which produces light. • Incandescent lamps: Incandescent lamps produce light by means of a filament heated to incandescence by the flow of electric current through it. The principle parts of an incandescent lamp, also known as GLS (General Lighting Service) lamp include the filament, the bulb, the fill gas and the cap. • Reflector lamps:Reflector lamps are basically incandescent, provided with a high quality internal mirror, which follows exactly the parabolic shape of the lamp. The reflector is resistant to corrosion, thus making the lamp maintenance free and output efficient. • Gas discharge lamps: The light from a gas discharge lamp is produced by the excitation of gas contained in either a tubular or elliptical outer bulb.The most commonly used discharge lamps are as follows:

Fluorescent tube lamps (FTL) Compact Fluorescent Lamps (CFL)Mercury Vapour Lamps Sodium Vapour Lamps Metal Halide Lamps

Page 145: Compressor -3 PDF

Most commonly used lamps

• Fluorescent lamps (FTL) • Compact Fluorescent Lamps (CFL) • Mercury Vapour Lamps • Sodium Vapour Lamps • Metal Halide Lamps

Page 146: Compressor -3 PDF

Luminaire Luminaire is a device that distributes, filters or transforms the light emitted from one or more lamps. The luminaire includes, all the parts necessary for fixing and protecting the lamps, except the lamps themselves. principles used in optical luminaire are reflection, absorption, transmission and refraction.Control GearThe gears used in the lighting equipment are as follows: § Ballast:A current limiting device, to counter negative resistance characteristics of any discharge lamps. In case of fluorescent lamps, it aids the initial voltage build-up, required for starting.§ Ignitors:These are used for starting high intensity Metal Halide and Sodiumvapour lamps.

Page 147: Compressor -3 PDF

Illuminance This is the quotient of the illuminous flux incident on an element of the surface at a point of surface containing the point, by the area of that element. The illuminanceprovided by an installation affects both the performance of the tasks and the appearance of the space.

Lux (lx): This is the illuminance produced by a luminous flux of one lux, uniformly distributed over a surface area of one square metre. One lux is equal to one lumen per square meter.

Luminous Efficacy (lm/W)This is the ratio of luminous flux emitted by a lamp to the power consumed by the lamp. It is a reflection of efficiency of energy conversion from electricity to light form.

Colour Rendering Index (RI)Is a measure of the degree to which the colours of surfaces illuminated by a given light source confirm to those of the same surfaces under a reference illuminent; suitable allowance having been made for the state of Chromatic adaptation.

Page 148: Compressor -3 PDF

Lighting System Approach

Ceiling Fixture

Lamps (light source)Ballast

Lens or Diffuser

Floor

Switch

Work SurfaceThe Requirement

Walls

Page 149: Compressor -3 PDF

Lighting Quality

• Illumination level.• Uniformity• Absence of glare.• Colour rendering index (CRI).

Page 150: Compressor -3 PDF

Luminaire

• This is a device that distributes, filters or transforms the light emitted from one or more lamps.

• The luminaire includes, all the parts necessary for fixing and protecting the lamps, except the lamps themselves.

• In some cases, luminaires also include the necessary circuit auxiliaries, together with the means for connecting them to the electric supply.

• The basic physical principles used in optical luminaire are reflection, absorption, transmission and refraction.

Page 151: Compressor -3 PDF

Gear

• Ballast– A current limiting device, to counter negative

resistance characteristics of any discharge lamps. In case of fluorescent lamps, it aids the initial voltage build-up, required for starting

• Ignitors– These are used for starting high intensity Metal

Halide and Sodium vapour lamps

Page 152: Compressor -3 PDF

Illuminance

• Is the quotient of the illuminous flux incident on an element of the surface at a point of surface containing the point, by the area of that element.

• The illuminance provided by an installation affects both the performance of the tasks and the appearance of the space.

• Lux (lx)– Is the illuminance produced by a luminous flux of one

lux, uniformly distributed over a surface area of one square metre.

Page 153: Compressor -3 PDF

Luminous Efficacy (lm/W)

Is the ratio of luminous flux emitted by a lamp to the power consumed by the lamp is a reflection of energy efficiency of conversion from electricity to light form

Page 154: Compressor -3 PDF

Colour Rendering Index (RI)

• Is a measure of the degree to which the colours of surfaces illuminated by a given light source confirm to those of the same surfaces under a reference illuminent; suitable allowance having been made for the state of Chromatic adaptation.

• The "color rendering index" (CRI) measures the effect of light on the perceived color of objects. To determine the CRI of a lamp, the color appearances of a set of standard color chips are measured with special equipment under a reference light source with the same correlated color temperature as the lamp being evaluated. If the lamp renders the color of the chips identical to the reference light source, its CRI is 100. If the color rendering differs from the reference light source, the CRI is less than 100. A low CRI indicates that some colors may appear unnatural when illuminated by the lamp.

Page 155: Compressor -3 PDF

Luminous Performance Characteristics of Commonly Used Luminaries

Lum / Watt Type of Lamp

Range Avg. Color Rendering

Index Typical Application Life (Hours)

Incandescent 8-18 14 Excellent Homes, restaurants, general lighting, emergency lighting

1000

Fluorescent Lamps

46-60 50 Good w.r.t. coating

Offices, shops, hospitals, homes

5000

Compact fluorescent lamps (CFL)

40-70 60 Very good Hotels, shops, homes, offices

8000-10000

High pressure mercury (HPMV)

44-57 50 Fair General lighting in factories, garages, car parking, flood lighting

5000

Halogen lamps 18-24 20 Excellent Display, flood lighting, stadium exhibition grounds, construction areas

2000-4000

High pressure sodium (HPSV) SON

67-121 90 Fair General lighting in factories, ware houses, street lighting

6000-12000

Low pressure sodium (LPSV) SOX

101-175 150 Poor Roadways, tunnels, canals, street lighting

6000-12000

Page 156: Compressor -3 PDF

Recommended Illuminance Levels for Various Tasks / Activities / Locations

Scale ofIlluminance:

The minimum illuminance for all non-working interiors, has been mentioned as 20 Lux (as per IS 3646). A factor of approximately 1.5 represents the smallest significant difference in subjective effect ofilluminance. Therefore, the following scale of illuminances is recommended.

20–30–50–75–100–150–200–300–500–750–1000–1500–2000, … Lux

Illuminanceranges:

Because circumstances may be significantly different for different interiors used for the same application or for different conditions for the same kind of activity, a range of illuminances is recommended for each type of interior or activity intended of a single value ofilluminance. Each range consists of three successive steps of the recommended scale of illuminances. For working interiors the middle value (R) of each range represents the recommended serviceilluminance that would be used unless one or more of the factors mentioned below apply.

Page 157: Compressor -3 PDF

Lighting Controls• On/off flip switches

• Timer control & auto timed switch off

• Presence detection

• Luminary grouping / Group Switching

• Day light linking, blinders, corrugated roof sheets

• Dimmers , Lighting voltage controllers

• Photo sensors

Page 158: Compressor -3 PDF

METHODOLOGY OF LIGHTING SYSTEM ENERGY EFFICIENCY STUDY

Step-1 : Inventorise the Lighting System elements, & transformers in the facility as per following typical format.

S. No.

Plant Location

Lighting Device

& Ballast Type

Rating in Watts

Lamp & Ballast

Population Numbers

Use / Shifts as I / II / III shifts /

Day

Page 159: Compressor -3 PDF

Energy savings in lighting System

• Make maximum use of natural light (North roof/translucent sheets/more windows and openings)

• Switch off when not required• Modify lighting layout to meet the need• Select light colours for interiors• Provide timer switches / PV controls• Provide lighting Transformer to operate at reduced voltage• Install energy efficient lamps, luminaries and controls• Clean North roof glass, translucent sheet and luminaries

regularly

Page 160: Compressor -3 PDF

Energy Saving in Lighting

• Separate lighting Transformer– To isolate from power feeder– To avoid voltage fluctuation problem– Energy saving at optimum voltage

• Install Servo stabilizer if separate transformer is not feasible

• High frequency electronic ballast's(30khz)– Energy savings 30 to 35%– Less heat load into A/C room

• Metal halide in place of Mercury and SVL lamps• CFT in place of incandescent lamps

Page 161: Compressor -3 PDF

End

Page 162: Compressor -3 PDF

DG set systemDG set systemSyllabusDiesel Generating systemFactors affecting selectionEnergy performance assessment of diesel conservation avenues

Page 163: Compressor -3 PDF

Typical Diesel CycleTypical Diesel Cycle

Page 164: Compressor -3 PDF

Specific fuel consumptionSpecific fuel consumptionThe specific fuel consumption has come down from a value of 220 g/kWh in the 1970s to a value around 160 g/kWh in present times.

Slow speed diesel engine, with its flat fuel consumption curve over a wide load range (50%-100%), compares veryfavourably over other prime movers such as medium speed diesel engine, steam turbines and gas turbines.

With the arrival of modern, high efficiency turbochargers, it is possible to use an exhaust gas driven turbine generator to further increase the engine rated output. The net result – lower fuel consumption per kWh and further increase in overall thermal efficiency. Turbocharger

Page 165: Compressor -3 PDF

A.C. GeneratorA.C. Generator ControlsControlsDiesel EngineDiesel Engine LoadLoad

AccessoriesAccessories

Excitation Control

Fuel Control

Foundation

Fig-9.2 DG Set System

Page 166: Compressor -3 PDF

DG Set as a SystemDG Set as a System

A diesel generating set should be considered as a system since its successful operation depends on the well-matched performance of the components, namely:

a) The diesel engine and its accessories.b) The AC Generator.c) The control systems and switchgear.d) The foundation and power house civil works.e) The connected load with its own components like heating,

motor drives, lighting etc.

Page 167: Compressor -3 PDF

Advantages of adopting Diesel Advantages of adopting Diesel Power Plants are:Power Plants are:

Low installation costShort delivery periods and installation periodHigher efficiency (as high as 43 -45 %)More efficient plant performance under part loadsSuitable for different type of fuels such as low sulphur

– heavy stock and heavy fuel oil in case of large capacities.Minimum cooling water requirements, Adopted with air cooled heat exchanger in areas

where water is not availableShort start up time

Page 168: Compressor -3 PDF

Sizing of a GensetIf the DG set is required for 100% standby, then the entire

connected load in HP / kVA should be added. After finding out the diversity factor, the correct capacity of a DG set can

be found out.

Example :Connected Load = 650 kWDiversity Factor = 1.86(connected load / demand)Max. Demand = 650/1.86 = 350 kW% Loading = 70Set rating = 350/0.7 = 500 kWAt 0.8 PF, rating = 625 kVA

Page 169: Compressor -3 PDF

High Speed Engine or High Speed Engine or Slow/Medium Speed EngineSlow/Medium Speed Engine

Factor Slow speed engine High speed engine

Break mean effective pressure -therefore wear and tear and consumption of spares

Low High

Weight to power ratio- therefore sturdiness and life

More Less

Space High Less

Type of use Continuous use Intermittent use

Period between overhauls* 8000 hours 3200

Direct operating cost (includes lubricating oils, filters etc.

Less High

Page 170: Compressor -3 PDF

Comparison of Various power Comparison of Various power generation optionsgeneration options

Description Units Combined GT & ST

Conventional Steam Plant

Diesel Engine Power Plants

Thermal Efficiency % 40 - 46 33 - 36 43 - 45

Initial Investment of Installed Capacity Rs./kW 8,500 - 10,000 15,000 -18,000 7,500 - 9,000

Cooling water requirement with once through cooling

(Lt/kWh)

Space requirement 125 % (App.) 250 % (App.) 100 % (App.)

Construction time Months 24 - 30 42 - 48 12 - 15

Project period Months 30 - 36 52 - 60 13 - 12

Auxiliary Power Consumption % 2 - 4 8 - 10 13 - 21

Plant Load Factor kWh/kW 6000 - 7000 5000 - 6000 7200 - 7500

Range of Control of Electrical output on Heavy oil

% 0 - 100 42 - 100 25 - 100

Start up time from cold minutes about 10 120 - 180 15 - 20

Page 171: Compressor -3 PDF

Altitude and Intake Temperature CorrectionsAltitude and Intake Temperature Corrections

Correction Factors For Engine Output

Altitude Correction Temperature CorrectionAltitude Meters over

MSL

Non Super Charged Super Charged Intake oC Correction

Factor

610 0.980 0.980 32 1.000

915 0.935 0.950 35 0.986

1220 0.895 0.915 38 0.974

1525 0.855 0.882 41 0.962

1830 0.820 0.850 43 0.950

2130 0.780 0.820 46 0.937

2450 0.745 0.790 49 0.925

2750 0.712 0.765 52 0.913

3050 0.680 0.740 54 0.900

3660 0.612 0.685

Page 172: Compressor -3 PDF

DeratingDerating due to Air Inter Cooler Water due to Air Inter Cooler Water Inlet TemperatureInlet Temperature

Water Temperature

oCFlow % Derating %

25 100 0

30 125 3

35 166 5

40 166 8

Page 173: Compressor -3 PDF

Power Factor:Power Factor:

The load power factor is entirely dependent on the load. The A.C. generator is designed for the power factor of 0.8 lag as specified by standards. Lower power factor demands higher excitation currents and results in increased losses. Over sizing A.C. generators for operation at lower power factors results in lower operating efficiency and higher costs. The economical alternative is to provide power factor improvement capacitors.

Page 174: Compressor -3 PDF

− Unbalanced Load: Unbalanced loads on A.C. generator leads to unbalanced set of

voltages and additional heating in A.C. generator. When other connected loads like motor loads are fed with unbalanced set of voltages additional losses occur in the motors as well. Hence, the load on the A.C. generators should be balanced as far as possible.

− Transient Loading: On many occasions to contain transient voltage dip arising due to

transient load application, a specially designed generator may have to be selected.

− Special Loads:Special loads like rectifier / thyristor loads, welding loads, furnace

loads need an application check. The manufacturer of diesel engine and AC generator should be consulted for proper recommendation so that desired utilisation of DG set is achieved without any problem.

Page 175: Compressor -3 PDF

Energy BalanceEnergy Balance& & Waste Heat Recovery in DG SetsWaste Heat Recovery in DG Sets

A typical energy balance in a DG set indicates following break-up:

Input : 100% Thermal EnergyOutputs : 35% Electrical Output

: 4% Alternator Losses: 33% Stack Loss through Flue Gases

: 24% Coolant Losses: 4% Radiation Losses

Page 176: Compressor -3 PDF

Typical Flue Gas Temperature and Flow Typical Flue Gas Temperature and Flow Pattern in a 5Pattern in a 5--MW DG Set at various MW DG Set at various

LoadsLoads

100% Load 11.84 kgs/Sec 370oC

90% Load 10.80 kgs/Sec 350oC

70% Load 9.08 kgs/Sec 330oC

60% Load 7.50 kgs/Sec 325oC

If the normal load is 60%, the flue gas parameters for waste heat recovery unit would be 320oC inlet temperature, 180oC outlet temperature and 27180 kgs/Hour gas flow. At 90% loading, however, values would be 355oC and 32,400 kgs/Hour, respectively.

Page 177: Compressor -3 PDF

Energy Saving Measures for DG Energy Saving Measures for DG SetsSets

a) Ensure steady load conditions on the DG set, and provide cold, dust free air at intake

b) Improve air filtration.c) Ensure fuel oil storage, handling and preparation as per manufacturers’

guidelines/oil company data.d) Consider fuel oil additives e) Calibrate fuel injection pumps frequently.f) Ensure compliance with maintenance checklist.g) Ensure steady load conditions, avoiding fluctuations, imbalance in phases,

harmonic loads.h) For base load operation, consider waste heat recovery system steam generation or vapour absorption system adoption.

i) consider partial use of biomass gas for generation. Ensure tar removal from the gas for improving availability of the engine in the long run.j) Consider parallel operation among the DG sets for improved loading .Carryout regular field trials to monitor DG set performance, and maintenance planning as per requirements.

Page 178: Compressor -3 PDF

Typical Format for DG Set MonitoringTypical Format for DG Set Monitoring

DG Set No.

Electricity Generating Capacity (Site), kW

DeratedElectricity Generating

Capacity, kW

Type of Fuel used

Average Load as % of DeratedCapacity

Specific Fuel Cons. Lit/kWh

Specific Lube Oil

Cons. Lit/kWh

1. 480 300 LDO 89 0.335 0.007

2. 480 300 LDO 110 0.334 0.024

3. 292 230 LDO 84 0.356 0.006

4. 200 160 HSD 89 0.325 0.003

5. 200 160 HSD 106 0.338 0.003

18. 880 750 LDO 78 0.345 0.007

19. 800 640 HSD 74 0.324 0.002

Page 179: Compressor -3 PDF

Energy Efficient Technologies

Page 180: Compressor -3 PDF

Maximum Demand

Page 181: Compressor -3 PDF

MD controller

Page 182: Compressor -3 PDF

Automatic Power Factor Controllers

Page 183: Compressor -3 PDF

Energy Efficient Motors

Page 184: Compressor -3 PDF

Design changes

Table 10.1 Watt Loss Area and Efficiency Improvement {PRIVATE}Watts Efficiency Improvement 1. Iron Use of thinner gauge, lower loss core steel reduces eddy current

losses. Longer core adds more steel to the design, which reduces losses due to lower operating flux densities.

2. Stator I 2 R Use of more copper and larger conductors increases cross sectional area of stator windings. This lowers resistance (R) of the windings and reduces losses due to current flow (I).

3. Rotor I 2 R Use of larger rotor conductor bars increases size of cross section, lowering conductor resistance (R) and losses due to current flow (I).

4. Friction & Windage Use of low loss fan design reduces losses due to air movement. 5. Stray Load Loss Use of optimised design and strict quality control procedures

minimizes stray load losses.

Page 185: Compressor -3 PDF
Page 186: Compressor -3 PDF

Technical aspects of Energy Efficient Motors

• Energy-efficient motors last longer, and may require less maintenance. At lower temperatures, bearing grease lasts longer; required time between re-greasing increases. Lower temperatures translate to long lasting insulation. Generally, motor life doubles for each 10°C reduction in operating temperature.

• Electrical power problems, especially poor incoming power quality can affect the operation of energy-efficient motors.

• Speed control is crucial in some applications. In polyphase induction motors, slip is a measure of motor winding losses. The lower the slip, the higher the efficiency. Less slippage in energy efficient motors results in speeds about 1% faster than in standard counterparts.

• Starting torque for efficient motors may be lower than for standard motors. Facility managers should be careful when applying efficient motors to high torque applications.

Page 187: Compressor -3 PDF

Soft Starters

Page 188: Compressor -3 PDF

Characteristics

Page 189: Compressor -3 PDF

Variable Frequency Drives

Motors connected to VFD provide variable speed mechanical output with high efficiency. These devices are capable of up to a 9:1 speed reduction ratio (11 percent of full speed), and a 3:1 speed increase (300 percent of full speed).

Page 190: Compressor -3 PDF

Variable Torque Vs. Constant Torque

• Variable torque loads include centrifugal pumps and fans, which make up the majority of HVAC applications.

• Constant torque loads include vibrating conveyors, punch presses, rock crushers, machine tools, and other applications where the drive follows a constant V/Hz ratio.

Typical full-load efficiencies are 95% and higher

Page 191: Compressor -3 PDF

Fluid coupling

Page 192: Compressor -3 PDF

Energy Efficient Transformers

1600 kVA AmorphousCore Transformer

Page 193: Compressor -3 PDF

Electronic Ballast

Page 194: Compressor -3 PDF

Energy Efficient Lighting Controls

• Occupancy Sensors• Timed Based Control• Daylight Linked Control• Localized Switching