2
www.fut-gmbh.de Compressed Air Heater - Series FT-F Compressed Air Heater Series FT-F Compressed air in-line heater packages with unique features to ensure variable compressed air temperature control from 20°C (68°F) to 120°C (248°F), ideally suitable for industrial or breathing air applications. The compressed air line heater systems use an open wound heating coil and a high accuracy output temperature sensing device. This combination of fast responding heater and sensor allows the unit to adjust quickly to any variations in flow rate or line pressure, without devi- ation in the output temperature. The heater is controlled by a compact solid state temperature controller mounted on top of the unit. The temperature is set using a rotary knob located at the top of the unit. The temperature is set using a rotary knob located at the top of the unit. The exact temperature output is indicated by a bi-metallic thermometer clearly visible at the front of the heater, providing an in- dependent indication of controller operation. Heaters can also be supplied, directly mounted to filtration pre-filters to ensure that process air is clean. Type Connection BSP Max. pressure (bar g) Material Dimension (mm) Weight (kg) Height Width FT-F 50 HB 3/8 16 Aluminium 340 90 1,00 FT-F 50 HF 3/8 16 Aluminium 340 175 2,30 FT-F 50 HT 3/8 16 Aluminium 340 140 1,30 FT-F 50 HFT 3/8 16 Aluminium 340 225 2,60 FT-F 100 HB 1/2 16 Aluminium 340 90 1,00 FT-F 100 HF 1/2 16 Aluminium 340 175 2,30 FT-F 100 HT 1/2 16 Aluminium 340 140 1,30 FT-F 100 HFT 1/2 16 Aluminium 340 225 2,60 A D B C A D B C C A D B A B C FT-F 50/100 HB FT-F 50/100 HT FT-F 50/100 HF FT-F 50/100 HFT Update: 12.08.2013

Compressed Air Heater - Home | F&T GmbH

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

www.fut-gmbh.de

Compressed Air Heater - Series FT-F

Compressed Air HeaterSeries FT-F

Compressed air in-line heater packages with unique features to ensure variable compressed air temperature control from 20°C (68°F) to 120°C (248°F), ideally suitable for industrial or breathing air applications. The compressed air line heater systems use an open wound heating coil and a high accuracy output temperature sensing device. This combination of fast responding heater and sensor allows the unit to adjust quickly to any variations in flow rate or line pressure, without devi-ation in the output temperature. The heater is controlled by a compact solid state temperature controller mounted on top of the unit. The temperature is set using a rotary knob located at the top of the unit. The temperature is set using a rotary knob located at the top of the unit. The exact temperature output is indicated by a bi-metallic thermometer clearly visible at the front of the heater, providing an in-dependent indication of controller operation. Heaters can also be supplied, directly mounted to filtration pre-filters to ensure that process air is clean.

Type Connection BSP Max. pressure (bar g) Material Dimension (mm) Weight (kg)

Height Width

FT-F 50 HB 3/8 16 Aluminium 340 90 1,00

FT-F 50 HF 3/8 16 Aluminium 340 175 2,30

FT-F 50 HT 3/8 16 Aluminium 340 140 1,30

FT-F 50 HFT 3/8 16 Aluminium 340 225 2,60

FT-F 100 HB 1/2 16 Aluminium 340 90 1,00

FT-F 100 HF 1/2 16 Aluminium 340 175 2,30

FT-F 100 HT 1/2 16 Aluminium 340 140 1,30

FT-F 100 HFT 1/2 16 Aluminium 340 225 2,60

A

D

B

C A

D

B

C CA

D

B

A

B

C

Model A39 TH & A55 TH Model A39 FH & A55 FH Model A39 FTH & A55 FTHModel A39 BH & A55 BHFT-F 50/100 HB FT-F 50/100 HT FT-F 50/100 HF FT-F 50/100 HFT

Upd

ate:

12.

08.2

013

www.fut-gmbh.de-Technical details to change without notice -Upd

ate:

12.

08.2

013

COM

PRESSED A

IR FILTERS

2929

heater & filter heater

Compressed air in-line heater packages ensure variable compressed air temperature control from 20°C (68°F) to 120°C (248°F), ideally suitable for industrial or breathing

air applications.

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

technical notes1 Drain valves are fitted as standard to all heaters and filters.2 When liquid, oil and water are present, FH or FTH models should be specified.3 Electrical connections to the unit are via an industry standard DIN connector.4 When placing an order, please specify voltage required. Example A39FTH-115.

FHfilter

modelpipe size

flow rate dimensions (mm) weight (kg)

complete price (£)

element model

element price (£)Nl/sec SCFM A B C

A39BH 13 27 88 337 130 1.0 533.00 - -

A39FH 13 27 176 337 130 2.3 643.00 E511 XA 60.00

A39TH 13 27 138 337 130 1.3 625.00 - -

A39FTH 13 27 226 337 130 2.6 734.00 E511 XA 60.00

A55BH ½ 26 54 88 337 130 1.0 667.00 - -

A55FH ½ 26 54 176 337 130 2.3 886.00 E511 XA 60.00

A55TH ½ 26 54 138 337 130 1.3 771.00 - -

A55FTH ½ 26 54 226 337 130 2.6 990.00 E511 XA 60.00

specificationHeater specification 230 volt AC 115 volt AC

Supply voltage 230 volt AC-50/60Hz 115 volt AC-50/60Hz

Power rating 1.5Kw 1.5Kw

Maximum working pressure 16 barg 232 psig 16 barg 232 psig

Controlled output range 20°C to 120°C 68°F to 248°F 20°C to 120°C 68°F to 248°F

Minimum inlet temperature -20°C -4°F -20°C -4°F

replacement parts for heater models

model description complete price (£)

WKN40037 replacement heating element P.O.A.

WKN40170 replacement printed circuit board P.O.A.

WKN40171 replacement sensor P.O.A.

WKN40173 replacement thermometer P.O.A.

20(68)

013 (27)

40(104)

60(140)

80(175)

100(212)

FLOW Nl/sec (SCFM)

26 (54)

A39BH &A55BH

A39FH &A55FH

A39TH &A55TH

A39FTH &A55FTH

Notes:1. Cool to touch heaters are manufactured from aluminium and carry the CE mark.2. If used in a breathing air installation, the air line heater and filter packages will not remove certain types of gases including Carbon Monoxide and Carbon Dioxide.3. Condensate drain: internal automatic float drain4. All filter bodies are electrophoretically painted and then coated with blue polyester powder paint finnish to eliminate corrosion.5. Airline heaters must not operate where liquid oil and water are present.6. Heaters and filter heaters are silicon free.

Supply voltage 230V AC 115V AC

Power rating 1,5 kw 1,5 kw

Maximum working pressure 16 bar g 16 bar b

Controlled ouput range 20°C bis 120°C 20°C bis 120°C

Minimum inlet temperature -20°C -20°C

Compressed Air Heater - Series FT-F