Purifying your compressed air, increasing your efficiency.
COMPRESSED AIR & GAS TREATMENT
Refrigeration dryers with Energy Saving Impulse Technology and Thermal MassNominal air flow 0,3 - 32,0 m³/min.
DEi
With the introduction of DE iTECH, the new generation of energy-saving refrigeration dryers, MTA not only renews its product offering for the compressed air treatment but also reinterprets the concept of thermal storage operation, that made the international success of the DE Hybrid dryers. The new Impulse Technology offers important advantages in terms of energy saving, reliability and operating costs as the DE iTECH dryer is able to adapt itself to the real needs of the compressed air system. The regulation system of the dryer controls the dryer operation granting the most energetically effective method of compressed air drying, achieving high energy saving and ensuring at the same time an excellent dew point stability also in dynamic conditions.
Refrigeration dryers with Energy Saving Impulse Technology and Thermal Mass
Enhanced Energy Savings
New 3-in-1 high efficiency heat exchanger with opti-mized fluid dynamics useful to keep the pressure drops to a minimum level. Advanced drying capacity control by impulses or by thermal stor-age effect. Enhanced energy savings (up to 80% compared with hot gas by-pass dryers).
User Friendly
DE iTECH automatically adapts itself to any operat-ing condition, without any need to adjust or switch OFF the dryer. User friendly digi-tal control is standard on all the models and shows all the main parameters, providing warnings and alarms to en-sure correct dryer operation.
Easy installation
Advanced design makes this dryer extremely compact and lightweight.Small footprint and frontal access for all controls and re-frigeration components save valuable plant floor space.
High Operating Limits
High maximum inlet tempera-ture +70 °C (DEiT 003-080) +60 °C (DEiT 101-320) and maximum ambient tempera-ture (+46°/50 °C) ensure a fail-safe operation at all times. High maximum operating pressure (16 barg).
Reliable Drying & Separation
The stainless steel demister separator efficiently removes the condensed moisture at all airflows (unlike centrifugal separators). This ensures a high grade of drying all the time.
DEi
UNBEATABLE ENERGY EFFICIENCY, LOW PRESSURE DROPS, MAXIMUM RELIABILITY, SYSTEM SIMPLIFICATION: THESE ARE
THE ADVANTAGES OF MTA DRYERS.
This revolutionary design matches energy consumption to the work load to achieve energy savings while in operation.Thanks to some sensors placed on the refrigeration and on the compressed air cir-cuits, the microprocessor controls the dryer operation granting the most effective method of compressed air drying.
• For high/medium flows, the dryer applies the Impulse Technology to regulate its drying capacity.
• For low air flows, the dryer utilizes the “thermal storage” operation.
IMPULSE TECHNOLOGY FOR HIGH/MEDIUM AIR FLOWS
The refrigerant compressor is permanently ON to achieve a perfect control of the dew point. The microprocessor controls through “impulses” the opening and closing of a solenoid valve installed on the suction pipe of the refrigeration compressor, in partial load conditions then only a small portion of the nominal refrigerant flows through a by-pass calibrated orifice of the solenoid valve to the compressor.In partial load conditions the compressor compresses less refrigerant than at peak load and therefore it consumes less energy (refrigerant flow control technology).
THERMAL STORAGE OPERATION FOR LOW AIR FLOWS
The refrigerant compressor cycles ON/OFF for maximum savings and reliability.Since the refrigeration capacity is greater than the load, the excess capacity cools the all-in-one exchanger that acts like a thermal storage.
IMPULSE TECHNOLOGYENERGY SAVING
Reliable operation
The simple refrigeration cir-cuit, without hot gas by-pass valve, and the careful selec-tion of the materials and components assure long, trouble free service life. The condenser coil is generously sized to maintain efficiency in all environments even at high ambient temperatures.
Robust Design
Heavy duty structure with panels protected by an epoxy polyester powder coating. Electrical panel (DEiT 140-320) is IP54 compliant with EN 60204-1 and tested for electromagnetic compatibility in accordance with applicable EMC standards. Phase monitor standard DEiT 165-320.
Respect of Environment
DE iTECH’s energy savings coupled with R134a and R410A non ozone depleting refriger-ants, reduce the environment impact minimizing the energy waste. Recyclable and high quality materials ensure re-spect of environment. and re-duced carbon footprint.
Guaranted Quality
All models are individually tested: refrigerant charge and leakage control, micro-processor and safety device setting verification. Leading brand components are used throughout, ensuring long term reliability.
Easy Serviceability
Removable frontal panel as-sures easy access to the main refrigeration components, thus facilitating maintenance op-erations also with dryer ON. There is no need of seasonal adjustments unlike hot gas by-pass dryers. Condenser fil-ters standard (DEiT 101-320) prevent mechanical equipment fouling by stopping debris.
Enhanced Energy Savings
ENERGY SAVING COMPARISONNormally a refrigeration dryer is sized to reach its nominal performance even in the most extreme conditions. In reality, these conditions are rarely achieved and the dryer works at partial load for most of its operating life. This is due to both the high variability of the compressed air flow of industrial plants and for the average operating temperature that normally is lower than the tempera-ture used to select the dryer itself. Only a dryer capable to adapt its working cycle to the real working conditions can provide a real energy savings.
HGBV
HGBVDE iTECH Scroll versionDE iTECH Piston version
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%0%
100%
80%
40%
60%
20%
% FLOW RATE
% A
BSO
RB
ED P
OWER
Hot Gas by-pass Valve (HGBV)“Non cycling” dryers work with the refrigerant compressor continuously run-ning independently from the inlet condition, using a by-pass valve to control evaporating pressure. Energy consumption remains almost constant also in absence of compressed air flow.
Impulse Technology (iTECH)Impulse Technology combines the technologies of regulation by impulses of the refrigerant flow (cooling capacity control for medium/high compressed air flow) and thermal storage effect (low compressed air flow) to produce maxi-mum energy savings and the lowest dew point.
DEW POINT COMPARISON
PDP HGB
T ev HGB
0% 20% 40% 60% 80% 100% 120% 140%0
9
45678
23
1
% COMPRESSED AIR FLOW
TEM
PER
ATU
RE
(°C)
Hot Gas by-pass Valve dryers (HGBV)• The HGBV valve is calibrated to compensate the whole cooling capacity of
the compressor in all ambient working conditions (5 °C ÷ 46°/50 °C).• The set-up of the HGBV valve at an ambient temperature of 5 °C is com-
pletely different from the one at 50 °C .• Normally for practical purpose the HGBV set-up is done at 25 °C ambient in
order to maintain 2 °C ÷ 4 °C evaporating temperature.• The consequence of this HGBV set-up is that the pressure dew point will
never be lower than 5 °C in order to avoid icing due to the collapse of evapo-ration at lower ambient temperatures.
Impulse Technology (iTECH)• At the contrary the Impulse Technology by MTA is able to control the flow
of refrigerant in order to match the thermal load with any external ambient temperature.
• The result is a perfect dew point control in every working condition ensuring nominal performance in CLASS 4.
HOW IT WORKSHot moist compressed air enters the Air-to-Air heat exchanger (1) where it is precooled by the dry air leaving the dryer. The refrigerant compressor (3) compresses the refrigerant gas and push it through the condenser (4) where it is condensed in high pressure liquid. The re-frigerant liquid then passes through a capillary/calibrated orifice (5) that meters it into the evapo-rator (2) as a low pressure liquid. The microprocessor adapts the working cycle to the real working conditions by controlling through “impulses” the opening and closing of the solenoid valve (6). In partial load conditions only a small portion of the refrigerant flows through the calibrated orifice of the solenoid valve (7) to the compressor that therefore consumes less energy.The precooled air enters the evaporator (2) where it is cooled to the required dew point by the incoming refrigerant liquid that changes phase and becomes a low pressure gas suitable to continue the process as it returns to the suction side of the refrigerant compressor (3). The exiting cold dry compressed air then returns to the Air-to-Air heat exchanger (1) where it is reheated by the incoming air, to prevent sweating in your plant.
ENERGY SAVING CALCULATIONS
Productivity Savings
Compressed air networks rarely operate at full load. Air compressors typically run at 70-80% of capacity for the first shift operation, further decreasing on second and third shifts because of variable process demands as well as sea-sonal fluctuations in ambient temperature. DEiTECH saves energy across the full load spectrum and maximizes the bottom line energy savings. The chart below shows a comparison between a DE iTECH 230 (23 m³/min) and a dryer which uses hot gas by-pass control. The DE iTECH 230 ensures an annual energy saving of 8103 kWh corresponding to a cost saving of 810 € and a reduction on annual CO² emissions of 2334 kg.
Compressed air flow 23 m³/min Non Cycling Dryers DE iTECH 230
Energy consumption per year Kwh 24370 16266
Energy cost per year € 2436 1626
CO² emission per year kg 7018 4684
Energy saving per year Kwh - 8103
Cost saving per year € - 810
CO² emission saved per year kg - 2334
(*) 6000 hours/year. Load profile: for 4800 h/year, load = 80%; for 1200 h/year, load = 30%. Energy costs = 0,1 €/ kWh.
Low Pressure Drops Savings
The pressure drops generated by a refrigerant dryer must be considered as an extra load that must be overcome by the compressed air compressor to en-sure the pressure level required. DE iTECH are designed and optimized from the fluid dynamics point of view to keep the pressure drops to a minimum. The graph represents the increase in power consumption (kWh per year) of a screw compressors 132 kW caused by the pressure drops (6000 working hours per year).
DE iTECH 230
0 0,13 0,23 0,30
2000
4000
6000
8000
10000
12000
Dp (bar)
kWh
/ Yea
r
DE iTECH 230 with a pressure drop 0,13 bar provides a considerable energy sav-ing respect another dryer with higher pressure drop 0,23 bar: Annual Energy Saving = (7945 - 4490) kWh/year = 3454 kWh/year. That corre-sponds to an yearly cost saving of 345 € (energy cost 0,10 € per kWh) and to a reduction on annual CO² emissions of 995 kg.
Total Productivity and Low Pressure Drops SavingsDE iTECH 230 (23 m³/min) Total savings per year
Total energy saving per year Kwh 11557
Total cost saving per year € 1155
CO² emission saved per year kg 3329
1
2
3
4
5
6
7
Built to perform
REFRIGERATION COMPRESSORS FULLY HERMETIC
Piston/rotary compressors (DEiT 003-140) ensure high reliability and long service life.Scroll compressors (DEiT 165-320) offer reduced energy consump-tions, low vibrations, less moving parts and high reliability.
ENVIRONMENTALLY FRIENDLY REFRIGERANTS
R134a refrigerant: DEiT 003-101R410A refrigerant: DEiT 121-320
HIGH EFFICIENCY 3-IN-1 HEAT EXCHANGER
3-in-1 compact aluminium heat exchanger including an Air-Air heat exchanger, the evaporator and a separator combined in a single module.
HIGH-PERFORMANCES CONDENSER
The air-cooled condenser is designed to ensure operation up to 50 °C external temperature and to achieve very high energy efficiency values. DEiT 003-032 are supplied with tubeless con-denser with steel fins protected by a double layer dipping paint-ing. DEiT 040-320 are equipped with a condenser coil with cop-per tubes and aluminium fins. Thanks to the ducted condenser coil, the maintenance activities are possible also with dryer ON. Condenser filters standard on DEiT 140-320.
Innovative design
NO NEED OF SEASONAL SETTING
DE iTECH features advanced microprocessor control technology, with all models fitted with easy to use digital controls. A comprehensive digital display keeps the user fully informed. Maintenance operations are simplified, and remote supervision RS485 can easily be supplied.
• The display shows continuously with icon-based menus the following parameters: Status of the dryer (OFF/dry/hdP); Status of the compressor; Status of condensate drain; Energy saving level; Alarms.
• 3 coded alarms ensuring faultless dryer operation.
• Programmable user alarm.
• Service warning, informing user that preventive maintenance should be carried out.
• Condensate drain control and programming, including manual drain test function.
• Remote ON/OFF function.
• General alarm contact for remote alarm indication.
• Possibility to connect the dryer to a supervisor system via RS485 Modbus (option).
ADVANCED DIGITAL CONTROL
Even with variable working conditions or ambient temperature the Impulse Technology let the DEiTECH to control accu-rately dew points without the need of any setting (HGBV requires recurring adjust-ment as ut is a mechanical device).
Built to perform
NEW ADVANCED 3-IN-1 HEAT EXCHANGER
3-in-1 compact aluminium heat exchang-er including an Air-Air heat exchanger, the evaporator and a separator combined in a single module.The new internal geometry allowed to opti-mize the fluid dynamics of the heat exchanger, increasing the exchange capacity with the same surface area, keeping pressure losses to a mini-mum level.
Air-to-Air Heat Exchanger
Hot and moist air enters the Air-to-Air heat exchanger where it exchanges heat in total counter flow with the outgoing cold air. Precooling saves energy by reducing the heat load on the evaporator section.
Evaporator (Air-to-Refrigerant Heat Exchanger)
The pre-cooled air enters the evaporator where it is cooled to the required dew point by exchanging heat in counter flow with the evaporating refrigerant, allowing maximum thermal exchange. The dew point tempera-ture is held within its optimum performance range by the microprocessor even under dif-fering ambient conditions.
Demister Separator
After cooling the cold air enters the high efficiency stainless steel separator where the condensate is removed by a demister fall-ing into the generously dimensioned drainage chamber or sump for disposal through the microprocessor controlled drain. The cold dry compressed air passes through the secondary side of the Air-to-Air heat exchanger where it is reheated by the hot inlet air it is precooling. Reheating prevents down-stream pipe sweating.
HIGH EFFICIENCY HEAT EXCHANGER
It is mandatory to install a pre-filter (min. filtration grade P 3μm) to prevent module and drainer clogging.
ELECTRIC POWER AND CONTROL PANEL
The control section is electrically isolated from the power section through a transformer. On DEiT 140-320 the power section is fit-ted with an interlocked door main switch to prevent access while power supply is ON. Electrical equipment is compliant with EN 60204-1 and electrical panel pro-tection degree IP54 compliant with EN 60529 (DEiT 140-320). Thanks to the dual frequency design the DEiT 101 and 165÷320 models are ready both for 50Hz and 60Hz applica-tions. A phase monitor (DEiT 165–320) provides protection against phase loss and phase reversal.
IMPULSE TECHNOLOGY
The microprocessor adapts the working cycle to the real working conditions by controlling through “impulses” the opening and closing of the solenoid valve.
ROBUST CABINET AND STRUCTURE
Heavy duty structure with panels protected by an epoxy polyester power coating RAL 7035. Simple and safe handling by forklift or pallet truck.
CONDENSATE DRAINS
All the dryers have microprocessor controlled drains. The drain open time and cycle time are fully adjust-able and the settings can be locked in to avoid tampering.Zero loss drain (option): a level sen-sor measures the level of the con-densed moisture and automatically opens a valve to drain it off, prevent-ing any pressure loss.
Technical data
DEiT 018 – 032
A B
C
D
F
E
DEiT 003 – 012
A D
FC
E B
DEiT 040 – 121
A B
C
D
E
F
DEiT 140 – 320
A B
C
D
F
E
Complete your compressed air treatment system with MTA aftercoolers, separators, filters, adsorption dryers, drains, oil-water separators and chillers.
Model
Nominal air flow (*)
Power supplyNominal
absorption power (*)
Airconnections
Overall dimensions (mm) Weight
CLASS 4 dew point ≤ 3 °C
Nominal flow rate
m3/min m3/h V/Ph/Hz kW Rp A B C D E F (Kg)
DEiT 003 0,3 18 230/1/50 0,12 3/8" 319 298 390 70 32 353 18
DEiT 005 0,5 30 230/1/50 0,16 3/8" 319 298 390 70 32 353 18
DEiT 007 0,7 42 230/1/50 0,19 3/8" 319 298 390 70 32 353 19
DEiT 009 0,9 54 230/1/50 0,19 1/2" 359 298 415 70 32 367 22
DEiT 012 1,2 72 230/1/50 0,29 1/2" 359 298 415 70 32 367 22
DEiT 018 1,8 108 230/1/50 0,35 1" 380 514 625 70 76 480 35
DEiT 026 2,6 156 230/1/50 0,47 1" 380 514 625 70 76 480 39
DEiT 032 3,2 192 230/1/50 0,56 1" 380 514 625 70 76 480 42
DEiT 040 4 240 230/1/50 0,74 1" 680 511 860 80 79 685 68
DEiT 050 5 300 230/1/50 0,78 1 1/2" 680 511 860 120 96 646 75
DEiT 060 6 360 230/1/50 0,84 1 1/2" 680 511 860 120 96 646 76
DEiT 070 7 420 230/1/50 0,95 1 1/2" 755 555 995 150 104 751 93
DEiT 080 8 480 230/1/50 1,10 1 1/2" 755 555 995 150 104 751 94
DEiT 101 10 600 230/1/50-60 1,33 2" 883 721 1107 150 123 821 138
DEiT 121 12 720 230/1/50 1,09 2" 883 721 1107 150 123 821 140
DEiT 140 14 840 230/1/50 1,28 2 1/2" 1170 939 1180 200 165 840 247
DEiT 165 16,5 990 400/3/50 (460/3/60) 1,78 2 1/2" 1170 939 1180 200 165 840 254
DEiT 190 19 1140 400/3/50 (460/3/60) 1,98 2 1/2" 1170 939 1180 200 165 840 255
DEiT 230 23 1380 400/3/50 (460/3/60) 2,24 2 1/2" 1170 939 1180 200 165 840 252
DEiT 270 27 1620 400/3/50 (460/3/60) 2,70 2 1/2" 1170 939 1180 200 165 840 276
DEiT 320 32 1920 400/3/50 (460/3/60) 3,56 2 1/2" 1170 939 1180 200 165 840 285
(*) Data refers to the following working conditions: power supply 50 Hz, air FAD 20 °C / 1bar A, pressure 7 bar(g), ambient temperature 25 °C, air inlet temperature 35 °C, according to ISO 8573.1 standard.Weights are net (without packing and for timed drain confirguration). Refrigerant fluids: R134a (DEiT 003-101), R410A (DEiT 121-320). Protection class IP22.Maximum working pressure 16 bar(g); maximum ambient temperature +50 °C (DEiT 003-101), +46 °C (DEiT 121-320); maximum inlet temperature +70 °C (DEiT 003-080), +60 °C (DEiT 101-320). The correction factors in the following table should be used as a guide only; for accurate selection at conditions differing from the above the selection software should be utilised.Capacity Correction Factors (indicative values): CAPACITY = RATED VALUE 7 bar(g) x K1 x K2 x K3.
working pressure bar (g) 3 4 5 6 7 8 9 10 11 12 13 14 15 16
correction factor K1 0,71 0,82 0,9 0,96 1,00 1,04 1,07 1,09 1,11 1,13 1,15 1,16 1,18 1,19
air inlet temperature °C 30 35 40 45 50 55 60 65 70
correction factor K2 1,23 1,00 0,81 0,66 0,57 0,52 0,48 0,44 0,40
ambient temperature °C 20 25 30 35 40 45 50
correction factor K3 1,05 1,00 0,95 0,89 0,84 0,78 0,72
MTA is represented in over 80 countries worldwide. For information concerning your nearest MTA representative please contact M.T.A. S.p.A.
The continuous improvement of MTA's products can cause some variations in the information herein even without prior notice. Reproduction in whole or in part is forbidden.
M.T.A. S.p.A.Viale Spagna, 8 ZI35020 Tribano (PD) Italy
Tel. +39 049 9588611Fax +39 049 9588676
[email protected] www.mta-it.com
MTA France S.A.Tel: +33 04 7249 8989www.mtafrance.fr
MTA Deutschland GmbHTel: +49 (2157) 12402 - 0www.mta.de
Novair-MTA, S.A.U. (España)Tel: +34 938 281 790www.novair-mta.com
SC MTA ROMÂNIA SrlTel: +40 723 022023www.mta-it.ro
MTA USA, LLCTel: +1 716 693 8651www.mta-usa.com
MTA Australasia Pty LtdTel: +61 1300 304 177www.mta-au.com
The
imag
es o
f the
pro
duct
s in
the
docu
men
t are
for
illus
trat
ive
purp
oses
onl
y an
d th
eref
ore
do n
ot h
ave
any
cont
ract
ual v
alue
.
5050
DD
EiT0
01G
B
12-
17
MTA products comply with European safety directives, as recognised by the CE symbol.
MTA is ISO9001 certified, a sign of its commitment to complete customer satisfaction.
EAC Declaration