295
Compact Bankable Directional Valves

Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Compact BankableDirectional Valves

Page 2: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

i

Product Selection Guide

Symbol Designation Model PortsPmax

bar (PSI)Qmax

l/min (GPM) Page

P1

LS1

T1

P

T

G LS

Basic inlet TA-00 SAE 8 210 (3000) 60 (15) 1

P1

LS1

T1

P

T

G

0 6 mm

LS

Inlet plate with LS drain TA-03 SAE 8 210 (3000) 60 (15) 3

LS

T

P

G

T1

LS1

P1Relief inlet TA-04 SAE 8 210 (3000) 60 (15) 5

T T1

PLS1P1

G LS

Relief and unloading inlet TA-05 SAE 8 210 (3000) 60 (15) 9

T1

LS1

P1

T

P

G LS

1

2

Compensator inlet TA-06 SAE 8 210 (3000) 60 (15) 13

P1

LS1

T1

P

T

G LSB

Priority fl ow control inletTA-28TA-38TA-48

SAE 8 210 (3000) P: 121 (32)P1: 68 (18) 17

LS1

T T1

P

G

P1

LS

1

2

Proportional inlet TA-10 SAE 8 210 (3000) 40 (11) 21

P

T

M

Inlet elements with pressure reducing valve on the P line TE-11 SAE 8 250 (3625) 50 (13.1) 25

Inlet elements from compact power module K to ED horizontal

TE-K > ED-O CPM-K 250 (3625) 35 (9.2) 29

A

PT

B A

PT

B

A

PLST

B

4/3 – 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

EDBY SAE 6 250 (3625) 15 (4) 31

Click on link below to go to the desired section

RA 15900-08/04.13 Product Selection Guide Hydraulics | Bosch Rexroth Corp. i

Page 3: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

ii

Product Selection Guide (continued)

A

PT

B A

PT

B

A

PLST

B

4/3 Directional valve elements with or without secondary relief valves, with or without LS connections, and with PO check valves

EDBY-VR SAE 6 250 (3625) 15 (4) 39

A

PT

B A

PT

B

A

PLST

B

4/3 – 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

EDBZ SAE 6 310 (4500) 25 (6.6) 47

A

PT

B A

PT

B

A

PLST

B

4/3 Directional valve elements with or without secondary relief valves, with or without LS connections, and with PO check valves

EDBZ-VR SAE 6 250 (3625) 20 (5.3) 57

4/2 Directional valve elements with or without secondary relief valves, with or without LS connections, and with 2/2 solenoid cartridge valve

EDBZ-VEI SAE 6 310 (4500) 25 (6.6) 67

A

P

T

B A

PLST

B 4/3 – 4/2 Directional valve elements with proportional control and with or without LS connections.

EDB-P SAE 6 310 (4500) 0-17 (0-4.5) 75

A

PT

PT

B

PLST

A B

A B

4/3 – 4/2 Directional valve elements with or without secondary relief valves, with or without LS connections.

ED1-Z SAE8 310 (4500) 30 (7.9) 83

A

PT

PT

B

PLST

A B

A B

4/3 – 4/2 Directional valve elements with or without secondary relief valves, with or without LS connections

ED2-DZ SAE 8 310 (4500) 50 (13.2) 95

A B

P

a a 0 b b

T

A B

P

a a 0

T

4/3 – 4/2 Directional valve elements with soft-shift ED2S-DZ G 3/8 310 (4500) 50 (13.2) 105

P

T

Directional valve elements with proportional control of Tank unloaded excess fl ow

ED4-PT — 310 (4500) 28 (7.4) 113

P P1

T T

Directional valve elements with compensated proportional control of Tank unloaded excess fl ow

ED4-PTC — 250 (3625) 40 (10.6) 123

Symbol Designation Model PortsPmax

bar (PSI)Qmax

l/min (GPM) Page

Click on link below to go to the desired section

Bosch Rexroth Corp. | Hydraulics Product Selection Guide RA 15900-08/04.13ii

Page 4: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

iii

Product Selection Guide (continued)

A

P

T

B A

PLST

B 4/3 – 4/2 Directional valve elements with proportional control and with or without LS connections

ED4-P SAE8 310 (4500) 45 (11.9) 131

A

P

T

B A

PLST

B 4/3 – 4/2 Directional valve elements with proportional hydraulic control and with or without LS connections

ED-IP SAE 8 310 (4500) 45 (11.9) 141

A

PT

B A

PLST

B 4/3 – 4/2 Directional valve elements with manual lever operated control and with or without LS connections

ED-LV SAE 8 310 (4500) 60 (15.8) 147

a

A B

P T b a

A B

P T b

4/2 and 4/3 on-off directional valve elements with fl ow sharing control (LUDV concept) PATENT PENDING

EDC-Z SAE 8 310 (4500) 23.5 (6.2) 155

a

A B

P T b a

A B

P T b

4/2 and 4/3 on-off directional valve elements with fl ow sharing control (LUDV concept)

EDC-DZ SAE 8 310 (4500) 48 (12.7) 167

a

A B

P T b a

A B

P T b

4/2 and 4/3 Proportional directional valve elements with fl ow sharing control (LUDV concept)PATENT PENDING

EDC-P SAE 8 310 (4500) 55 (14.5) 179

P1

T1

P2

T2

M

Intermediate elements with check valves for emergency pump TI-00 — 250 (3625) 50 (13.2) 191

M

PLS

T

P1LST1

Intermediate elements with pressure reducer, and relieving TI-03 — 250 (3625) 50 (13.2) 193

M

P

T

P1

T1

Intermediate elements with fl ow regulator on P line TI-04 — 250 (3625) 50 (13.2) 195

Intermediate elements with 2 way compensator, and with LS connec-tions

TI-C2 — 310 (4500) 30 (7.9) 197

EDM4 12Intermediate elements for interfacing ED with M4-12

TI-M4-12 >ED — 310 (4500) — 199

Symbol Designation Model PortsPmax

bar (PSI)Qmax

l/min (GPM) Page

Click on link below to go to the desired section

RA 15900-08/04.13 Product Selection Guide Hydraulics | Bosch Rexroth Corp. iii

Page 5: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

iv

PLS

T

P1LS1T1

Intermediate elements with double acting hand pump EPM-DE-18 — 310 (4500) — 201

P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203

A B

Cross-port relief stacking modules EDM-CR SAE 8 210 (3000) 60 (15) 205

Flow control stacking modules EDM-FC SAE 8 210 (3000) 60 (15) 207

Counterbalance stacking modules EDM-CB SAE 8 210 (3000) 60 (15) 209

B

T

AFlangeable elements with single or double secondary pressure relief valves and anti-cavitation function

EDCMF-VM SAE 8 310 (4500) 30 (7.93) 211

A

T

B

Flangeable elements with secondary pressure relief valve single or double

EDCMF-VM5 SAE 8 310 (4500) 50 (13.2) 215

A BFlangeable elements with single or double acting cross piloted check valves

EDCMF-VR SAE 8 310 (4500) 70 (18.5) 219

P

T

Outlet elements basic TC SAE 6SAE 8 250 (3625) 30 (8)

60 (15) 223

P1

M1

P

T

T1

Outlet elements with pressure relief valve and with P, T and M ports for downstream operators

TC-04 G 3/8 250 (3625) 35 (9.2) 225

Accessories and fi xation elements 227

Cartridge Valves 233

Product Selection Guide (continued)

Symbol Designation Model PortsPmax

bar (PSI)Qmax

l/min (GPM) Page

Click on link below to go to the desired section

Bosch Rexroth Corp. | Hydraulics Product Selection Guide RA 15900-08/04.13iv

Page 6: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

v

Introduction

Bosch Rexroth Oil Control (DCOC - Drive Control Oil Control) manufactures a wide range of solenoid and directional valves for different applications grouped by typology in the present catalogue.

For valves not included in this catalogue, please consult Bosch Rexroth Oil Control.

Technical Data

The solenoid valves are composed by:

high strength cast iron body, with control spool made of special heat treated steel for long-lasting performance; 1 or 2 oil immersed sole-noids and 1 or 2 coils made by copper wire winding, with isolating coating, optimized for high hydraulic performance with limited current absorption.

The directional valves bodies can be manufactured with different materials like high strength cast iron, steel or high strength wrought aluminium; their internal parts are manufactured with top quality steel processed with the most advanced machinery, which combines high production capacity with full and precise control of dimensions.

All external cast iron or steel parts are protected by zinc plating; aluminium parts are available with and without anodizing; special coating is available on request.

All solenoid valves are designed according to the highest specifi cations and are manufactured and tested with the most advanced machin-ery and equipment which combines high production capacity with full and precise control of dimensions.

Ports, when present, can be drilled according to different specifi cations like: G sizes (BSPP) according to UNI-ISO 228/1; Metric with O-Ring, or with fl at washer, according to UNI-ISO 6149; SAE threaded ports UN-UNF 2B; BSPP thread with O-Ring, according to JIS 2351-90 Type “O”.

Seals:

O-Rings: are made with acrylonitrile/butadiene, commonly called BUNA-N (or NBR, according to ASTM and ISO), standard for tempera-tures between -20°C and +80°C [-68°F and + 176°F]. Special O-Rings for higher temperatures can be supplied upon request.

Back-up Rings and Slide Rings are made of reinforced poly-tetrafl uoroethylene (PTFE), or BUNA-N (NBR) as well.

Quality System Approval Orders

DCOC distributes its valves through its sales network in compliance with the delivery terms shown in the specifi c documents. Customer orders must be transmitted to the Vendor in written form (via fax, telecommunication, or electronic means) and must contain the following information:

a) date and place of issue of the order;

b) exact name of the Customer company and its complete shipping and billing addresses;

c) a reference to the offer made by the Vendor company with the relevant agreed prices (if such an offer exists);

d) valid Vendor’s part numbers and description/specifi cation of all the products to which the order refers;

e) the required quantities;

f ) the quality requirements with which the Vendor must comply;

g) the signature of an authorized representative;

h) the required delivery date;

i) terms of payment;

j) shipping agent

For Customers supplied by DCOC directly, the orders are offi cially as accepted when the relevant order confi rmation, duly signed by DCOC, arrives at the Customer; or, if such a document is not forthcoming, orders will be considered confi rmed by the Vendor, at the terms requested, if they are not explicitly refused in writing within 10 working days from the order date.

NOTE: except if otherwise agreed with the Customer, DCOC can introduce technical modifi cations to the product specifi cations without notice; in any event, DCOC undertakes to execute customer orders/contracts which are already confi rmed without applying any modifi ca-tions to the product and/or anyway guaranteeing product interchange.

RA 15900-08/04.13 Product Selection Guide Hydraulics | Bosch Rexroth Corp. v

Page 7: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

vi

Product Quality and Compliance to the Specifications

All DCOC valves are subject to the necessary checks/tests in various production phases in order to guarantee compliance with the speci-fi cations and settings shown in the catalogues, drawings, and/or technical data sheets. The Customer may make visits to and to carry out Quality AUDITS at the Vendor’s plant, provided that a specifi c appointment is agreed.

Due to the wide range of variants and operating conditions of the equipment manufactured by the Customers, DCOC does not assume any liability for the results of tests performed by third parties. The Customer is therefore responsible for the fi nal choice of the valve and for the adoption of all the measures required to achieve the functional and safety specifi cations of the system in which the valve is to be installed, in addition to the compliance with any specifi c regulation or standard applicable to the system in question.

In the event of product non compliance due to Vendor’s mistake, in addition to the warranty coverage here described, the Customer can demand the Vendor to perform the necessary corrective actions in order to promptly improve its quality level.

Application Limitations

The Customer is expressly prohibited from using the products sold by the Vendor for purposes other than those specifi ed in the offer, catalogs, or technical documentation.

Specifi cally, DCOC ‘s Dealers or Agents are not authorised to approve the use of DCOC valves for the following applications:

− any passenger or goods carrying road vehicle or equipment subject to Highway Safety Standards and Directives, such as (without limita-tion) steering, or brake systems;

− aircraft or space vehicles;

− ordnance equipment;

− medical and health products, including life support equipment or vehicles;

− systems to be used under any Nuclear Regulatory Act or Regulation;

− systems for use in explosive or otherwise hazardous environments.

If the Customer intends to use the valves supplied for any applications falling into one or more of the above categories or other similar categories, or for any applications other than those expressly described in the documentation, or in case of doubts concerning the applica-tion, he must require prior specifi c authorisation directly from DCOC and proceed only after such authorisation has been issued in writing.

Any damage suffered by the Customer or third parties arising from failure to comply with the above mentioned terms and limitations, or due to non compliance to DCOC’s instructions/specifi cations shown in the catalogue pages or in the technical drawings, will be borne entirely by the Customer himself.

Customer's Obligations to Prevent Damages within His Own Production Process

If the valves are employed in a production process which could cause substantial damage to the Customer or to third parties in case of assembly line stopping as consequence of defects or lack of availability of valves, the Customer has the responsibility to maintain a safety stock in order to promptly replace the defective or missing parts; the Customer undertakes to engineer the production cycle so that the replacements can be carried out easily.

In any event, DCOC will be responsible for the repair or replacement of any part or valve found to be defective due to its own manufactur-ing causes.

Warranty

DCOC warrants the original purchaser of its valves that the products are free from defects in material and workmanship, when handled, installed and operated under normal conditions, in accordance with DCOC and Industry recommended practises, for a period of 12 months from the fi rst installation, provided that the installation date is within 6 months from the manufacturing date marked on the valve itself.

Seals and O-Rings are expressly excluded from the warranty.

This warranty is applicable only to the original purchaser of the valves, and is not transferable.

This warranty will not apply to products that have been subject to conditions of contamination in the customer’s hydraulic circuit, or to products which have been incorrectly handled, fi tted, used or modifi ed/disassembled without the Vendor’s supervision or authorisation.

In the event that the Customer believes that the valves or parts of valves supplied are defective for causes attributable to the Vendor, the Customer shall notify the alleged defects by sending a detailed written report, thereby allowing the Vendor to understand and verify the nature of the claimed defects, also through its authorised technical personnel.

Bosch Rexroth Corp. | Hydraulics Product Selection Guide RA 15900-08/04.13vi

Page 8: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

vii

Once the defect has been analysed and after determination that the defect is attributable to the Vendor’s fault, DCOC will repair or replace the valve within a reasonable time and/or inform the Customer of the cause of such defect.

The DCOC warranty policy does not provide for refund or credit for the defective material; specifi cally DCOC shall not be held responsible under any circumstances for loss of profi t, costs of disassembly and reassembly of the product, nor for any damages connected with such operation, nor for any cost related to the fi tting of the repaired or replaced valves, including losses of earnings related to machine being temporarily out of service.

If the valve supplied is to be fi tted in assembly plants potentially capable of causing damages to third parties of magnitude signifi cantly greater than the cost of the valve itself, it is the Customer’s responsibility to adopt all the possible safety measures in order to avoid any such damages; in fact, the production of valves at competitive market prices cannot ensure the total absence of defects, in spite of DCOC’s continuous concern to provide top quality products. Should the Customer face the need of a Recall Campaign in which an DCOC valve is involved, DCOC’s involvement shall be discussed and agreed between DCOC and the Customer prior to the start of any action. Should the Customer face a problem connected with an DCOC valve and potentially capable to raise a “Product Liability” case, the Customer shall immediately notify the Vendor who will participate to the joint analysis of the problem, together with the Customer.

NOTE: any warranty condition or obligation different from this policy can be effective only if specifi cally agreed and undersigned by both Parties: Customer and Vendor.

Technical Assistance

DCOC guarantees to the Customer its availability to perform free of charge a joint analysis of any defect reported by end users, also when such analysis is to be carried out at the Customer’s site, provided that the timing is reciprocally agreed.

However, if the malfunction is found to be not due to DCOC’s responsibility, the Vendor will issue a debit note to the Customer for the cost of the services rendered. When the Customer requires the assistance of DCOC’s engineers on its sites, he shall make a written request to this effect (which can be transmitted also by e-mail or fax).

Statement

The valves described in this catalogue can be employed in systems or machines falling under the specifi cations of the EEC European Directive 2006/42/CE (Machine Directive) and later amendments. The valves shall not be operated, adjusted or disassembled before the complete machines are verifi ed to be in compliance with the requirements of the above mentioned Directive.

Applicable Law

For all matters that are here omitted, any delivery performed by DCOC directly will be subject to the applicable provisions of the Italian law.

If the Customer’s address is in a Foreign Country, any case of dispute, also of “International nature”, which should arise from these sales conditions shall be subject to the provisions of the Italian Law, with the sole competence of the Court of Modena – Italy.

ATTENTION

Limited to the valves and related products here included, this catalogue cancels and supersedes any prior issue.

All rights are reserved. It is specifi cally forbidden to reproduce partially or totally the present catalogue.

RA 15900-08/04.13 Product Selection Guide Hydraulics | Bosch Rexroth Corp. vii

Page 9: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

viii

Viscosity Class and Filtration Data

Table A

Viscosity classKinematic viscosity

Maximum at 0°C (0°F) Medium at 40°C (64°F) Minimum at 100°C (212°C)

ISO VG 10 90 10 2.4

ISO VG 22 300 22 4.1

ISO VG 32 420 32 5.0

ISO VG 46 780 46 6.1

ISO VG 68 1400 68 7.8

ISO VG 100 2560 100 9.9

Table B

Type of systemType of valve

L.C. fi ltration recommendations

Nominal fi ltration (micron)

Absolute fi ltration rating ISO 4572 (Betax ≥ 75)

Contamination class according to:

ISO 4406 NAS 1638

System/components operating at High Pressure >250 bar (3500 PSI)

High Duty Cycle Applications Systems/components with

LOW dirt tolerance

10 X = 10...12 19 / 17 / 14 8

System/components operating at Medium High Pressure

High Duty Cycle ApplicationsSystems/components with moderately dirt tolerance

15 X = 12... 15 20 / 18 / 15 9

System/components operating at Low Pressure <100 bar (1450 PSI)

Low Duty Cycle Applications Systems/components with

GOOD dirt tolerance

25 X = 15... 25 21 / 19 / 16 10

Bosch Rexroth Corp. | Hydraulics Product Selection Guide RA 15900-08/04.13viii

Page 10: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-01/10.11

Inlet Plate –Basic

TA-00

1

1/2

Circuit

P1

LS1

T1

P

T

G LS

Description

The inlet elements TA-00-__ are employed to connect the external P, T lines to the P, T channels inside the ED elements of the Directional Valve Assembly and to connect to the LS ports of the elements equipped with LS channels.

− Port sizes: P and T – SAE 8; LS and G – SAE 4. − Includes a test point port “G” for pressure gauge connection. − Special plating and coating availabe, C.F.

Technical Features

Maximum pressure bar [psi] 210 [3000]*

Maximum inlet fl ow l/min [gpm] 60 [15]

Material Aluminum

Seals NBR

Fluid Temperature °C [°F] –20 to +80 [–4 to +176]

* For higher pressure, C.F.

Page 11: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics TA00 RA 18300-01/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

2

2/2

Overall Dimensions

LSG P

T17.5

[0.6

9]

18.3[0.72]

19.0[0.75]

20.4

[0.8

0]50

.1[1

.97]

19.5[0.77]

T1

LS1

(2) M637.5

[1.47]

13.0[0.51]

P1

(3) M8

7.5

[0.2

9]

34.0

[1.3

4]

22.5[0.88]

30.0[1.18]

74.9[2.95]

42.0

[1.6

5]74

.9[2

.95]

49.5

[1.9

5]

mm[Inches]

Third angleprojection

Ordering details

T A - 0 0 - 56

Inlet elements 56 =Port size

SAE 8

Note! P1 and T1 use 9mm diameter fl ow restrictor.

Page 12: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-03/01.13

Inlet Plate –with LS Drain

TA-03

3

1/2

Circuit

P1

LS1

T1

P

T

G

0.6 mm

LS

Description

The inlet elements TA-03-__ are employed to connect the external P, T lines to the P, T channels inside the ED elements of the Directional Valve Assembly and to connect to the LS ports of the elements equipped with LS channels. The LS line can be drained to tank by choosing the size of orifi ce required.

− Port sizes: P and T – SAE 8; LS and G – SAE 4. − Includes a test point port “G” for pressure gauge connection. − Special plating and coating availabe, C.F.

Technical Features

Maximum pressure bar [psi] 210 [3000]*

Maximum inlet fl ow l/min [gpm] 60 [15]

Material Aluminum

Seals NBR

Fluid Temperature °C [°F] –20 to +80 [–4 to +176]

* For higher pressure, C.F.

Page 13: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics TA00 RA 18300-03/01.13

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

4

2/2

Overall Dimensions

G

LS

41.9[1.65]

7.62[0.30]

22.35[0.88]

29.97[1.18]

(3) M8

(2) M6

DO NOT STAMP OR PAINT ON THIS SURFACE

37.59[1.48]

55.37[2.18]

74.93[2.95]

50.04[1.97]

20.57[0.81]

74.93[2.95]

Ordering details

T A - 0 3 - 5 6

Inlet elements 00 =04 =05 =06 =

Orifice sizeNo drain

0.4 mm (0.016 inch) orifice0.5 mm (0.020 inch) orifice0.6 mm (0.024 inch) orifice

56 =Port size

SAE 8

Page 14: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

5

RA 18300-02/10.11

Inlet Plate – Relief

TA-04

1/4

Description

The inlet elements TA-04-__ are employed to connect the external P, T lines to the P, T channels inside the ED elements of the Directional Valve Assembly and to connect to the LS ports of the elements equipped with LS channels. They incorporate a pressure relief cartridge which limits the maximum primary pressure in the P line and unloads to Tank any excess fl ow.

− Port sizes: P and T – SAE 8; LS and G – SAE 4. − Special plating and coating available, C.F.

Technical Features

Maximum pressure bar [psi] 210 [3000]*

Maximum inlet fl ow l/min [gpm] 60 [15]

Material Aluminum

Seals NBR

Fluid Temperature °C [°F] –20 to +80 [–4 to +176]

* For higher pressure, C.F.

Circuit

LS

T

P

G

T1

LS1

P1

Page 15: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

6

Bosch Rexroth Corp. | Hydraulics TA-04 RA 18300-02/10.112/4

Overall Dimensions

LSG

T P

7.5

[0.2

9]

40.6

[1.6

0]

17.5

[0.6

9]

15.5[0.61]

30.1[1.19]

18.8[0.74]

58.0[2.28]

20.3

[0.8

0]

58.0[2.28]

(2) M6

(3) M8

31.6

[1.2

4]74

.9[2

.95]

P1

T1

LS1

25.0[0.98]

30.0[1.18]74.9

[2.95]57.1

[2.25]132.1[5.20]

42.7

[1.6

8]

mm[Inches]

Third angleprojection

Note! P1 and T1 use 9mm diameter fl ow restrictor.

Page 16: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

7

RA 18300-02/10.11 TA-04 Hydraulics | Bosch Rexroth Corp. 3/4

T A - 0 4 - 56 -

Ordering Details

Inlet element

Port sizeSAE 8 = 56

D =P =

Relief typeDirect acting

Pilot operated

0 =1 =2 =3 =

1 =2 =3 =

Pressure rangeDirect acting

5–70 bar (75–1000 PSI)*35–140 bar (500–2000 PSI)

105–210 bar (1500–3000 PSI)175–350 bar (2500–5000 PSI)

Pilot operated35–140 bar (500–2000 PSI)

70–280 bar (1000–4000 PSI)140–420 bar (2030–6000 PSI)

* Minimum pressure setting intended with Q = 5 LPM (1.3 GPM)

Page 17: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

8

Bosch Rexroth Corp. | Hydraulics TA04 RA 18300-02/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

4/4

Page 18: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

9

RA 18300-05/10.11

Inlet Plate – Relief and Dump

TA-05

1/4

Description

The inlet elements TA-05-__ are employed to connect the external P and T lines to the P and T channels inside the ED elements of the Directional Valve Assembly. They incorporate a pressure relief cartridge which limits the primary pressure in the P line. The relief setting can be checked through the Test Point port G. When fi tted, the Normally Open Solenoid Unloading VEI Cartridge unloads to Tank all the P line fl ow; unloading stops when the cartridge coil is energized.

− Port sizes: P and T – SAE 8; LS and G – SAE 4.

− Ports LS and G are provided with plugs.

− Special plating and coating available, C.F.

Technical Features

Maximum pressure bar [psi] 210 [3000]*

Maximum inlet fl ow l/min [gpm] 60 [15]

Material Aluminum

Seals Buna N (NBR)

Fluid Temperature °C [°F] –20 to +80 [–4 to +176]

* For higher pressure, C.F.

Circuit

T T1

PLS1P1

G LS

Page 19: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics TA-05 RA 18300-05/10.11

10

2/4

Overall Dimensions

LS

G

P

T

28.8[1.13]

7.5

[0.3

0]

57.2

[2.2

5]

87.6[3.45]

46.4[1.83]

30.8

[1.2

1]68.8

[2.71]

29.4

[1.1

6]

19.3[0.76]

17.5

[0.6

9]

19.6[0.77]

68.1[2.68]

(2) M6

(3) M8

P1

T1

LS1

87.6

[3.4

5]

30.0[1.18]

57.1[2.25]

65.0[2.56]

84.3[3.32]

229.1[9.02]

33.1

[1.3

0] 54.8

[2.1

6]

mm[Inches]

Third angleprojection

Assembly tag

Note! P1 and T1 use 9mm diameter fl ow restrictor.

Page 20: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-05/10.11 TA-05 Hydraulics | Bosch Rexroth Corp.

11

3/4

Ordering Details

T A - 0 5 - 5 6 - - - -

Inlet element

Port sizeSAE 8 = 56

Pressure rangeDirect acting35–140 bar (500–2000 PSI)105–210 bar (1500–3000 PSI)175–350 bar (2500–5000 PSI)Pilot operated35–140 bar (500–2000 PSI)70–280 bar (1000–4000 PSI)140–420 bar (2030–6000 PSI)

= 1= 2= 3

= 1= 2= 3

Relief typeDirect actingPilot operated

= D= P

A =C =

Dump valve override type**No manual override

Push & Twist manual override

00 =OB =OC =

Coil features*VoltageNo coil12 Vdc24 Vdc

00 =01 =07 =

Coil features*Connection type

No coilDIN 43650

Deutsch DT04-2P

* Alternate connections and voltages available, see page 265.

** Alternate 2-way solenoid cartridge options available, see pages 253 and 257.

Page 21: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics TA05 RA 18300-05/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

12

4/4

Page 22: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

13

RA 18300-06/10.11

Inlet Plate – Compensator (Unloading)

TA-06

1/4

Description

The inlet elementsTA-06-__ are employed to connect the external P, T lines to the P, T channels inside the ED elements of the Directional Valve Assembly and to connect to the LS ports of the elements equipped with LS channels. An LS controlled 3-way compensator provides pressure compensated fl ow to the ED elements of the Directional Valve Assembly. The same 3-way compensator is also controlled by a pilot relief cartridge and unloads to tank any excess fl ow in order to limit the primary pressure in the system.

− Port sizes: P and T – SAE 8; LS and G – SAE 4. − Ports LS and G are provided with plugs − Special plating and coating available. C.F.

Technical Features

Maximum pressure bar [psi] 210 [3000]*

Maximum inlet fl ow l/min [gpm] 60 [15]

Material Aluminum

Seals Buna N (NBR)

Fluid Temperature °C [°F] –20 to +80 [–4 to +176]

* For higher pressure, C.F.

Circuit

T1

LS1

P1

T

P

G LS

1

1

2

2= Code option= Orifice provision, C.F.

Page 23: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics TA-06 RA 18300-06/10.11

14

2/4

Overall Dimensions

P

T

LS

G

18.5[0.73]30.0

[1.18]87.6

[3.45]

13.2[0.52]

126.6[4.99]

7.5

[0.3

0]

61.0

[2.4

0]

33.5[1.32]

72.8[2.87]

19.0

[0.7

5]34

.9[1

.37] 49

.5[1

.95]74

.9[2

.95]

P1

T1

LS19.0

[0.35]

17.5

[0.6

9]30

.5[1

.20]

17.8[0.70]

(2) M6

(3) M8

mm[Inches] Third angle

projection

Assembly tag

Note! P1 and T1 use 9mm diameter fl ow restrictor.

Page 24: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-06/10.11 TA-06 Hydraulics | Bosch Rexroth Corp.

15

3/4

Ordering Details

T A - 0 6 - 5 6 - - -

Inlet element

Port sizeSAE 8 = 56

Pressure range25–100 bar (360–1450 PSI)100–200 bar (1450–2900 PSI)200–350 bar (2900–5000 PSI)

= 1= 2= 3

0 =1 =

LS drain optionsPlugged (standard)

LS drain orifice – 0.5 mm (0.020 in.)

00 =04 =08 =14 =17 =

Compensator bias*Adjustable – 2–8 bar (30–115 PSI)

Fixed – 4 bar (58 PSI) Fixed – 8 bar (116 PSI)

Fixed – 14 bar (203 PSI)Fixed – 17 bar (247 PSI)

D =Relief type

Direct acting

* Standard setting for “00” is 4 bar (60 PSI). For further detail see catalog page 235.

Page 25: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics TA06 RA 18300-06/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

16

4/4

Page 26: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

17

RA 18300-08/10.11

Inlet Plate – Priority Flow Control

TA-_8

1/4

Description

The inlet elements TA-_8-__ are employed to connect the external P and T lines to the P1 pressure lines and tank lines in the ED elements of the Directional Valve Assembly. The main functions are: to limit the maximum primary pressure in the P line and to control the priority fl ow (P1) in the ED elements of the Directional Valve Assembly, with the excess fl ow delivered to port B for a secondary actua-tion.*

Both priority (P1) and by-pass fl ow (A) can be separately unloaded to tank through the two solenoid (VEI*) cartridges 1 and 2.

− Port sizes: P, T, and B – SAE 8; LS and G – SAE 4. − Relief valve is available in direct-acting and pilot-operated.

* Three circuit types are available for confi gurations of B to tank line, P to tank line, and P to B line.

Technical Features

Maximum pressure bar [psi] 210 [3000]*

Maximum inlet fl ow at P l/min [gpm] 121 [32]

Maximum inlet fl ow at P1 l/min [gpm] 68 [18]

Material Aluminum

Seals Buna N (NBR)

Fluid Temperature °C [°F] –20 to +80 [–4 to +176]

* For higher pressure, C.F.

Circuit

T T1

LS1

P

G B

P1

LS

P1

LS1

T1

P

T

G LSB

T T1

LS1

P

G B

P1

LS

= 28

= 38

= 48

Page 27: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics TA-08 RA 18300-08/10.11

18

2/4

Note! P1 and T1 use 9mm diameter fl ow restrictor.

Overall Dimensions

T

P B

LS

G

P1

T1LS1

28.8[1.13]30.0

[1.18]125.7[4.95]

57.1[2.25]

29.2

[1.1

5]10

0.3

[3.9

5]

70.5[2.77]

41.9

[1.6

5]78

.1[3

.07]

53.8[2.12]

85.7[3.37]

106.0[4.17]

19.3[0.76]

17.5

[0.6

9]

85.7[3.37]

36.8

[1.4

5]

(2) M6

(3) M8

65.0[2.56]

84.3[3.32]

267.2[10.52]

7.5

[0.2

9]

86.4

[3.4

0]

mm[Inches] Third angle

projection

Assembly tag

Page 28: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-08/10.11 TA-08 Hydraulics | Bosch Rexroth Corp.

19

3/4

Ordering Details

T A - - 5 6 - - - - -

Inlet element

Circuit type (See page 15)= 28= 38= 48

Port sizeSAE 8 = 56

Pressure rangeDirect acting35–140 bar (500–2000 PSI)105–210 bar (1500–3000 PSI)175–350 bar (2500–5000 PSI)Pilot operated35–140 bar (500–2000 PSI)70–280 bar (1000–4000 PSI)140–420 bar (2030–6000 PSI)

= 1= 2= 3

=1=2=3

Relief typeDirect actingPilot operated

= D= P

15 =23 =29 =37=45 =58 =63 =0V =

VRF setting type*Fixed – 15 l/min (4.0 GPM)Fixed – 23 l/min (6.0 GPM)Fixed – 29 l/min (8.0 GPM)

Fixed – 37 l/min (10.0 GPM)Fixed – 45 l/min (12.0 GPM)Fixed – 58 l/min (15.0 GPM)Fixed – 63 l/min (17.0 GPM)

Adjustable – 2–50 l/min (0.6–13.21 GPM)

A =C =

Dump valve override type**No manual override

Push & Twist

00 =OB =OC =

Voltage***No coil12 Vdc24 Vdc

00 =01 =07 =

Connection type***No coil

DIN 43650Deutsch DT04-2P

* Other fi xed fl ow rates available on request. See page 231 – consult factory.

** Alternate 2-way solenoid cartridge options available see pages 253 and 257.

*** Alternate voltages and connections available, see page 265.

Page 29: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics TA-08 RA 18300-08/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

20

4/4

Page 30: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

21

RA 18300-09/10.11

Inlet Plate – Proportional Flow Control with LS Controlled Compensation and Unloading Valve

TA-10

1/4

Description

The inlet elements TA-10-__ are employed to connect the external P, T lines to the P, T channels inside the ED elements of the Directional Valve Assembly and to connect to the LS ports of the ED elements equipped with LS channels. The LS signal is sent downstream of the proportional fl ow restrictor VEP*: it provides a proportional pressure compensated fl ow, across the VEP*, for the ED elements of the Directional Valve Assembly, and it unloads the excess fl ow. The main functions are: to limit the maximum primary pressure in the P line and to supply proportional pressure compensated fl ow the ED elements of the Directional Valve Assembly.

− Port sizes: P and T – SAE 8; LS and G – SAE 4. − Ports LS and G are provided with plugs. − Special plating and coating available, C.F.

Technical Features

Maximum pressure bar [psi] 210 [3000]*

Maximum inlet fl ow l/min [gpm] 40 [11]

Material Aluminum

Seals Buna N (NBR)

Fluid Temperature °C [°F] –20 to +80 [–4 to +176]

* For higher pressure, C.F.

Circuit

LS1

T T1

P

G

P1

LS

1

1

2

2= Code option= Orifice provision, C.F.

Page 31: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics TA-10 RA 18300-09/10.11

22

2/4

Overall Dimensions

T

P

LSG

19.8[0.78]

30.0[1.18]

92.1[3.62]

26.8[1.05]

7.5

[0.3

0]

61.0

[2.4

0]

10.3[0.40]

17.5

[0.6

9]

22.8

[0.9

0]76

.2[3

.00]

19.4[0.76]

34.8[1.37]

18.8[0.74]

47.2[1.86]

30.5

[1.2

0]46

.1[1

.81]

100.

3[3

.95]P1

T1

LS1

(2) M6

(3) M8

93.2[3.67]

107.4[4.23]

226.3[8.91]

mm[Inches]

Third angleprojection

Assembly tag

Note! P1 and T1 use 9mm diameter fl ow restrictor.

Page 32: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-09/10.11 TA-10 Hydraulics | Bosch Rexroth Corp.

23

3/4

Ordering Details

T A - 1 0 - 5 6 - - - - -

Inlet element

Port sizeSAE 8 = 56

Pressure range25–100 bar (360–1450 PSI)100–200 bar (1450–2900 PSI)200–350 bar (2900–5000 PSI)

= 1= 2= 3

Relief typeDirect acting = D

Connection type*No coilDIN 43640Deutsch DT04-2P

= 00= 01= 07

P =L =

LS optionsP feed compensator

LS feed compensator

01 =02 =03 =

Prop. max. flow20 l/min (5.3 GPM)30 l/min (7.9 GPM)40 l/min (11 GPM)

A =C =

Dump valve override typeNo manual override

Knob-style manual override

00 =OB =OC =

Voltage*No coil12 Vdc24 Vdc

* Alternate voltages and connections available see page 265.

Page 33: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics TA-10 RA 18300-09/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

24

4/4

Page 34: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-10/10.11

Inlet Plate with Pressure Reducing Valve on the P Line

TE-11-__-

25

1/4

Description

The inlet elements TE-11-__ are employed to connect the external P and T lines to the P and T channels inside the ED elements of the Directional Valve Assembly. They incorporate a 3-way pressure reducing / relieving cartridge which allows to control the primary pressure in the P line of the ED elements. The primary pres-sure can be adjusted and can be checked and through the Test Point port M.

− Ports sizes: P and T – SAE 8; Test port M – SAE 4.

Technical Data (for applications outside these parameters, please consult us)

GeneralModel Weight TE-11-56-S_- kg (lbs) 0.54 (1.19)Ambient Temperature °C (°F) –20....+50 (–4....+120)

HydraulicMaximum pressure bar (PSI) 250 (3625)Maximum inlet fl ow l/min (GPM) 50 (13.2)Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR]

Permissible degree of fl uid contaminationISO 4572: βx≥75 X=12...15ISO 4406: classe 20/18/15NAS 1638: classe 9

Viscosity range mm2/s 5....420

P

T

M

Circuit

Page 35: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics TE-11 RA 18300-10/10.112/4

26

1 Flange specifi cations for coupling to the ED Directional Valve Elements (for Version TE-11-02…).

2 Three threaded holes M 8 for coupling of the ED Directional Valve Elements. Recommended bolt strength class: DIN 8.8. Torque 17–19 Nm [12.5–14 ft-lb].

3 Hydraulic Ports P-T SAE 8, for versions TE-11-56.

1) 2)

6)

4)3)

5)

External Dimensions and Fittings

4 Test Point port SAE 4, for versions TE-11-56-…

5 Pressure Reducing/Relieving Cartridge VRPR, with screw type adjuster (refer to RE 18301-91).

6 Pressure Reducing/Relieving Cartridge VRPR, with hand-knob type adjuster (refer to RE 18301-91).

Page 36: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-10/10.11 TE-11 Hydraulics | Bosch Rexroth Corp. 3/4

27

Ordering Details

FamilyInlet Elements

Configurationwith pressure reducing valve on the P line

Ports3/4-16 UNF-2B (SAE8) = 56

Pressure Reducing Valve range Without Pressure Reducing Valve Pressure range 2–25 bar (30–350 PSI)Pressure range 10–50 bar (145–758 PSI)Pressure range 28–80 bar (400–1160 PSI)

= 0= 1= 2= 3

Material Aluminium

0 =S =K =

Type of pressure adjustment Without Pressure Reducing Valve Screw type adjuster Hand-knob type adjuster

T E - 1 1 - 5 6 - - A L

Page 37: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics TE-11 RA 18300-10/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

28

4/4

Page 38: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-11/10.11

Inlet Element for Interfacing a Horizontal Directional Control Valve ED to a K Series Power Unit

TE-K-ED-O

29

1/2

Function, section

The inlet elements TE-K-ED-0 are employed to connect a directional control valve ED type to a K series power unit. When needed, the TE-K-ED-0 elements can incorporate a check valve (shown with dotted lines in the hydraulic symbol). The directional control valve assembly should develop in horizontal direction.

− Body made of Black Anodized Aluminium (EN-AW 2011 T6 )

Technical Data (for applications outside these parameters, please consult us)

GeneralWeight kg (lbs) 0.71 (1.56)Ambient Temperature °C (°F) –20....+50 (–4....+120)

HydraulicMaximum pressure bar (PSI) 250 (3625)Inlet maximum pressure l/min (GPM) 50 (13.10)

Hydraulic fl uidGeneral properties: it must have physical lubrica-ting and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR]

Permissible degree of fl uid contaminationISO 4572: βx≥75 X=12...15ISO 4406: classe 20/18/15NAS 1638: classe 9

Viscosity range mm2/s 5....420

Connection element between an horizontal directional control valve ED to a K series power unit

Circuit

Page 39: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics TE-K-ED-O RA 18300-11/10.112/2

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

30

External Dimensions and Fittings

1 Flange specifi cations for coupling to the ED Direc-tional Valve Elements.

2 Three threaded holes M 8 for coupling of the ED Directional Valve Elements. Recommended bolt strength class: DIN 8.8. Torque 20-22 Nm [16.2-17.7 ft-lb].

3 Two through holes for installation on the hydraulic power unit.

Power unit side

ED directional control valve side

Installation scheme

Ordering Details

Code Description

R933007063 TE-K-ED-O

Page 40: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-50/10.11

4/3, 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

B8_05… (EDBY)

31

1/8

Summary

Description Page

General specifi cations 1

Ordering Details 2

Confi guration 2

Spool variants 3

Principles of operation, cross section 3

Technical Data 4

Δp-Qv characteristic curves 5

Performance limits 5

External Dimensions and Fittings 6

Electric connection 7

General specifications

− Valve elements with 4 ways and 3, or 2, positions.

− Control spools directly operated by screwed-in solenoids with extractable coils.

− In the de-energized condition, the control spool is held in the central position by return springs.

− Wet pin tubes for DC coils, with push rod for mechanical overri-de; burnish surface treatment.

− Coils can be rotated 360°around the tube.

− Manual override (push-button or screw type) available upon request.

− Plug-in connectors available: EN 175301-803 (Was DIN 43650); DT04-2P (Deutsch).

Page 41: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBY RA 18300-50/10.112/8

32

B 8 _ 0 5 _ _ _ _ _ _ _ _ _ _ 0 _

Ordering Details

1) The required hydraulic symbol and spool variant can be chosen by consulting page 3.

2) Only for confi guration 1.* Without secondary valve, the standard confi guration corresponds

to “0”.** Additional ports on request.Note: the secondary valve has a maximum fl ow capacity of 6 l/min. (1.6 GPM).

Configuration

0 =P =F =

Optional fittingsStandard emergency

Push-button type emergency Screw type emergency

0 =1 =2 =

Secondary valves setting 2)

50-210 bar (725-3045 PSI) *100-310 bar (1450-4500 PSI)

25-50 bar (362-725 PSI)

B =Ports**

9/16-18 UNF 2-B (SAE6)

00 =01 =02 =

07 =

Electric connectionsWithout coils

With coils, without connectorsWith coils and with non-assembled connectors, type EN 175301-803

With coils having DEUTSCH DT 04-2P connector

Family Directional valve elements EDB

TypeSize 4

Configuration *Standard With secondary valve on AWith ch. for Load Sensing

= 0= 1= 4

Coil type C31

Spool variants 1)

4/3 operated on both sides a and b 4/2 operated on side a only

= _ 2 _ _= _ 3 _ _

Voltage supplyWithout coil 12V DC 24V DC

= 00= OB= OC

A

PT

B A

PT

B

A

PLST

B

= 0 = 1

= 4

Page 42: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-50/10.11 EDBY Hydraulics | Bosch Rexroth Corp. 3/8

33

Spool variants

Principles of operation, cross section

The sandwich plate design directional valve elements B8_05… are very compact direct operated solenoid valves which control the start, the stop and the direction of the oil fl ow. These elements basically consist of a stackable housing (1) with a control spool (2), one or two solenoids (5), and one or two return springs (4). When energized, the force of the solenoid (5) pushes the control spool (2) from its neutral-central position “0” to the required end position “a” or “b”, and the required fl ow from P to A (with B to T), or P to

B (with A to T) is achieved. Once the solenoid is de-energized, the return spring (4) pushes the spool thrust washer (3) back against the housing and the spool returns in its neutral-central position.

Each coil is fastened to the solenoid tube by a ring nut (6). A pin (7) allows to push the spool (2) in emergency conditions, when the solenoid cannot be energized, like in case of voltage shortage.

A

= A201

= B201

= X301

= Y301

= C201

= E201

= K201

B

Pa a 0 a 0b b a

T

A B

P T

05 _ 2 _ _ 05 _ 3 _ _

7 6 5 4 3 1 2 3 4 5 6 7

Page 43: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBY RA 18300-50/10.114/8

34

Technical Data (for applications with different specifications consult us)

General

Valve element with 2 solenoids and plug-in pins EN 175301-803 kg (lbs) 1.2 (2.65)

Valve element with 1 solenoidand plug-in pins EN 175301-803 kg (lbs) 1.0 (2.20)

Ambient Temperature °C (°F) –20....+50 (–4....+122) [NBR seals]

Hydraulic

Maximum pressure at P, A and B ports bar (PSI) 250 (3625)

Maximum dynamic pressure at T bar (PSI) 150 (2176)

Maximum static pressure at T bar (PSI) 210 (3045)

Maximum inlet fl ow l/min (GPM) 15 (4)

Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR seals]

Permissible degree of fl uid contamination ISO 4572: βx≥75 X=12...15ISO 4406: class 20/18/15NAS 1638: class 9

Viscosity range mm2/s 5....420

Electrical

Voltage type DC

Voltage tolerance (nominal voltage) % –10 .... +10

Duty Continuous, with ambient temperature ≤ 50°C (122°F)

Maximum coil temperature °C (°F) 150 (302)

Insulation class H

Compliance with Low Voltage Directive LVD 73/23/EC (2006/95/EC), 2004/108/EC

Coil weight with connection EN 175301-803 kg (lbs) 0.18 (0.4)

Voltage V 12 24

Voltage type DC DC

Power consumption W 20 20

Current 1) A 1.72 0.86

Resistance 2) Ω 6.97 27.88

1) Nominal 2) ± 7% at temperature 20°C [68°F]

Voltage (V) Connector type Coil description Marking Coil Mat no.

= OB 01= OB 02 12 DC EN 175301-803

(Ex. DIN 43650) C3101 12DC 12 DC R933002776

= OB 07 12 DC DEUTSCH DT 04-2P C3107 12DC 12 DC R933002778

= OC 01= OC 02 24 DC EN 175301-803

(Ex. DIN 43650) C3101 24DC 24 DC R933002777

= OC 07 24 DC DEUTSCH DT 04-2P C3107 24DC 24 DC R933002779

Page 44: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-50/10.11 EDBY Hydraulics | Bosch Rexroth Corp. 5/8

35

The performance curves are measured with fl ow going across and coming back, like P > A and B > T, with symmetrical fl ow areas.In case of special circuit connections, the performance limits can change.

Performances limits

Measured with the solenoids at their operating temperature, 10% under voltage and without pre-loading of the tank.

Spool VariantsCurve No.

P > T P > A P > B A > T B > T

A201 2 1 1 1 1

B201 3 3 2 2

C201 4 4 4 4 4

E201 3 3 4 4

K201 3 3 4 3

Y301 2 3 3 2

X301 3 3 3 3

Spool Variants Curve No.

A201 3B201 2C201 1E201 1K201 3X301 1Y301 2

Characteristic curves

Measured with hydraulic fl uid ISO-VG32 at 45° ± 5° C (113° ± 9° F); ambient temperature 20° C (68° F).

Lowest pressure setting curve for secondary valves

Secondary valve setting Curve No.

50–210 bar (700–2950 PSI) 0

100–310 bar (1400–4500 PSI) 1

25–50 bar (350–700 PSI) 2

Minimum flow for efficiency of LS control

4

116 8

6

4

2

0

100

50

0

3 2 1

Pre

ssur

e Δp

PSI bar

0

0

5 10 15

1 2 3 4

l/min

GPMFlow Q

3 2 1

Pre

ssur

e Δp

PSI bar

l/min

GPMFlow Q

3625 250

200

150

100

50

0

3000

2000

1000

00

0

5 10 15

1 2 3 4

Pre

ssur

e Δp

PSI bar

l/min

GPMFlow Q

000 1 2 3 4 5 6

0 0.3 0.4 0.9 1.2 1.6

900

750

600

450

300

150

60

50

40

30

20

10

Pre

ssur

e Δp

PSI bar

0

10

20

30

40

50

60

0

150

300

450

600

750

900

l/min

GPMFlow Q

0 1 2 3 4 5 6

0 0.3 0.4 0.9 1.2 1.6

012

Page 45: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBY RA 18300-50/10.116/8

36

External Dimensions and Fittings

1 Solenoid tube hex 12.7 mm (0.5 inch). Torque 15–16 Nm (11–11.8 ft-lb).

2 Ring nut for coil locking [OD 20.5 mm (0.81 inch)]; torque 3–4 Nm (2.2–3 ft-lb).

3 Identifi cation label.

4 Clearance needed for connector removal.

5 Optional push-button emergency, EP type, for spool opening: it is pressure stuck to the ring nut for coil locking. Mat no. R933000042.

6 Optional screw type emergency, EF type, for spool open-ing: it is screwed (torque 6–7 (4.4–5.2 ft-lb)] to the tube as replacement of the coil ring nut. Mat no. R933006377.

7 Flange specifi cations for coupling to ED intermediate elements.

8 One through hole for coupling of the ED Directional Valve Elements. Recommended tie rod M8 with strength class DIN 8.8. Torque 20–22 Nm (14.7–16.2 ft-lb).

9 O-Rings for P and T ports.

10 Space needed for secondary valve.

11 Plug for 2 positions versions (4/2); hex 22 mm, torque 20–22 Nm (14.7–16.2 ft-lb).

12 A and B ports.

Page 46: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-50/10.11 EDBY Hydraulics | Bosch Rexroth Corp. 7/8

37

Electric connection (or connections, in case of two solenoids)

= 00

Without coils, but with ring nut and O-Rings for coil fi tting (solution recommended for fl exible stock handling)

= 01

With coils having plug-in pins EN 175301-803, without connectors

= 02

With coils and with connectors non-assembled, type EN 175301-803.

Protection class: IP 65 when connector with seal is properly screwed down, and cable clamp is

correctly tightened.

182-09: Standard

Material No. DescriptionR933002885 182-09 GRAYR933002889 182-09 BLACK

=07

With coils having DEUTSCH DT 04-2P connector, and with bi-directional diode.

Protection class: IP 69 K with female connector properly fi tted (see drawing).

Page 47: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBY RA 18300-50/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

8/8

38

Page 48: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-51/10.11

4/3 Directional valve elements with or without secondary relief valves, with or without LS connections, and with PO check valves

B8_45… (EDBY-VR)

39

1/8

Summary

Description Page

General specifi cations 1

Ordering Details 2

Confi guration 2

Spool variants 3

Principles of operation, cross section 3

Technical Data 4

Δp-Qv characteristic curves 5

Performance limits 5

External Dimensions and Fittings 6

Electric connection 7

General specifications

− Valve elements with 4 ways and 3 positions.

− Control spools directly operated by screwed-in solenoids with extractable coils.

− In the de-energized condition, the control spool is held in the central position by return springs.

− Wet pin tubes for DC coils, with push rod for mechanical overri-de; burnish surface treatment.

− Single or Dual cross piloted checks on A and B ports.

− PO checks with 4:1 pilot ratio.

− Coils can be rotated 360° around the tube.

− Manual override (push-button or screw type) available upon request.

− Plug-in connectors available: EN 175301-803 (Was DIN 43650); DT04-2P (Deutsch).

Page 49: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBY-VR RA 18300-51/10.11

40

2/8

B 8 _ 4 5 _ _ _ _ _ _ _ _ _ _ _ _

Ordering Details

1) The required hydraulic symbol and spool variant can be chosen by consulting page 3.

2) Only for confi guration 1.* Without secondary valve, the standard confi guration corresponds

to “0”.** Additional ports on request.Note: the secondary valves have a maximum fl ow capacity of 6 l/min. (1.6 GPM).

Configuration

0 =P =F =

Optional fittingsStandard emergency

Push-button type emergency Screw type emergency

1 =3 =

PO check valve positionCheck valve on port A

Check valve on both ports A and B

0 =1 =2 =3 =

Secondary valves setting 2)

50-210 bar (725-3045 PSI) 1)

100-310 bar (1450-4500 PSI) 1) 25-50 bar (362-725 PSI) 1)

Without secondary valves

B =Ports**

9/16-18 UNF 2-B (SAE6)

00 =01 =02 =

07 =

Electric connectionsWithout coils

With coils, without connectorsWith coils having connectors

EN 175301-803With coils having DEUTSCH DT 04-2P

connector

Family Directional valve elements EDB

TypeSize 4

Configuration *Standard With secondary valve on AWith ch. for Load Sensing

= 0= 1= 4

Coil type C31

Spool variants 1)

4/3 operated on both sides a and b = _ 2 _ _

Voltage supplyWithout coil 12V DC 24V DC

= 00= OB= OC

A

PT

B A

PT

B

A

PLST

B

= 0 = 1

= 4

Page 50: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-51/10.11 EDBY-VR Hydraulics | Bosch Rexroth Corp. 3/8

41

Spool variants

Principles of operation, cross section

A B

Pa a 0 b a 0 bb a b

= B201

= E201

T P T

A B

The sandwich plate design directional valve elements B8_45… are very compact direct operated solenoid valves which control the start, the stop and the direction of the oil fl ow. These elements basically consist of a stackable housing (1) with a control spool (2), two solenoids (5), and two return springs (4). The upper part of the housing is extended in order to provide space for the cavities where two PO check valves are fi tted. They consist of two calibra-ted balls (10), with return springs (11), which allow upstream fl ow but lock on the respective seats (9) and prevent the return fl ow. The return fl ow is possible when they are opened by the pilot piston (8), if enough pilot pressure is present in the opposite line.

When energized, the force of the solenoid (5) pushes the control spool (2) from its neutral-central position “0” to the required end position “a” or “b”, and the required fl ow from P to A (with B to T), or P to B (with A to T) is achieved.

Once the solenoid is de-energized, the return spring (4) pushes the spool thrust washer (3) back against the housing and the spool (2) returns in its neutral-central position.

Each coil is fastened to the solenoid tube by a ring nut (6). A pin (7) allows to push the spool (2) in emergency conditions, when the solenoid cannot be energized, like in case of voltage shortage.

12

7 6 5 4 3 1 2 3 4 5 6 7

11 10 9 8 9 10 11 12

45 _ 2 ________ 3 45 _ 2 ________ 1

Page 51: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBY-VR RA 18300-51/10.11

42

4/8

Technical Data (for applications with different specifications consult us)

General

Valve element with 2 solenoids and plug-in pins EN 175301-803 kg (lbs) 1.6 (3.5)

Ambient Temperature °C (°F) –20....+50 (–4....+122) [NBR seals]

Hydraulic

Maximum pressure at P, A and B ports bar (PSI) 250 (3625)

Maximum dynamic pressure at T bar (PSI) 150 (2176)

Maximum static pressure at T bar (PSI) 210 (3045)

Maximum inlet fl ow l/min (GPM) 15 (4)

Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR seals]

Permissible degree of fl uid contamination ISO 4572: βx≥75 X=12...15ISO 4406: class 20/18/15NAS 1638: class 9

Viscosity range mm2/s 5....420

Electrical

Voltage type DC

Voltage tolerance (nominal voltage) % –10 .... +10

Duty Continuous, with ambient temperature ≤ 50°C (122°F)

Maximum coil temperature °C (°F) 150 (302)

Insulation class H

Compliance with Low Voltage Directive LVD 73/23/EC (2006/95/EC), 2004/108/EC

Coil weight with connection EN 175301-803 kg (lbs) 0.18 (0.4)

Voltage V 12 24

Voltage type DC DC

Power consumption W 20 20

Current 1) A 1.72 0.86

Resistance 2) Ω 6.97 27.88

1) Nominal 2) ± 7% at temperature 20°C [68°F]

Voltage (V) Connector type Coil description Marking Coil Mat no.

= OB 01= OB 02 12 DC EN 175301-803

(Ex. DIN 43650) C3101 12DC 12 DC R933002776

= OB 07 12 DC DEUTSCH DT 04-2P C3107 12DC 12 DC R933002778

= OC 01= OC 02 24 DC EN 175301-803

(Ex. DIN 43650) C3101 24DC 24 DC R933002777

= OC 07 24 DC DEUTSCH DT 04-2P C3107 24DC 24 DC R933002779

Page 52: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-51/10.11 EDBY-VR Hydraulics | Bosch Rexroth Corp. 5/8

43

The performance curves are measured with fl ow going across and coming back, like P > A and B > T, with symmetrical fl ow areas.In case of special circuit connections, the performance limits can change.

Performances limits

Characteristic curves

Lowest pressure setting curve for secondary valves

Minimum flow for efficiency of LS control

174 12

8

10

6

2

4

0

150

100

50

0

3 2 1

Pre

ssur

e Δp

PSI bar

0

0

5 10 15

1 2 3 4

l/min

GPMFlow Q

900

750

600

450

300

150

0

PSI60

30

40

50

20

10

0

Pre

ssur

e Δp

bar

0

0

1 2 3 4 5 6

0.3 0.90.6 1.2 1.6

l/min

GPMFlow Q

900

750

600

450

300

150

0

PSI60

30

40

50

20

10

0

Pre

ssur

e Δp

bar

0

0

1 2 3 4 5 6

0.3 0.90.6 1.2 1.6

l/min

GPMFlow Q

012

3625

3000

2000

1000

0

Pre

ssur

e Δp

PSI250

200

150

50

100

0

2 1bar

0

0

5 10 15

1 2 3 4

l/min

GPMFlow Q

Measured with hydraulic fl uid ISO-VG32 at 45° ± 5° C (113° ± 9° F); ambient temperature 20° C (68° F).

Measured with the solenoids at their operating temperature, 10% under voltage and without pre-loading of the tank.

Spool VariantCurve No.

P > A P > B A > T B > T

B201 2 2 1 1

E201 2 2 3 3

Spool Variant Curve No.

B201 2

E201 1

Secondary valve setting Curve No.

50–210 bar (700–2950 PSI) 0

100–310 bar (1400–4500 PSI) 1

25–50 bar (350–700 PSI) 2

Page 53: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBY-VR RA 18300-51/10.11

44

6/8

External Dimensions and Fittings

1 Solenoid tube hex 11 mm (0.43 inch).Torque 15–16 Nm (11–11.8 ft-lb).

2 Ring nut for coil locking (OD 20.5 mm); torque 3–4 Nm (2.2–3 ft-lb).

3 Identifi cation label.

4 Clearance needed for connector removal.

5 Optional push-button emergency, EP type, for spool opening: it is pressure stuck to the ring nut for coil locking. Material no. R933000042

6 Optional screw type emergency, EF type, for spool opening: it is screwed (torque 6–7 Nm [4.4–5.2 ft-lb]) to the tube as replacement of the coil ring nut. Material no. R933006377.

7 Flange specifi cations for coupling to ED intermediate elements.

8 One through hole for coupling of the ED Directional Valve Elements. Recommended tie rod M8 with strength class DIN 8.8. Torque 20–22 Nm (14.7–16.2 ft-lb).

9 O-Rings for P and T ports.

10 Space needed for secondary valve.

11 Plug hex. 6 mm; torque 30–33 Nm (22–24 ft-lb).

12 A and B ports.

Page 54: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-51/10.11 EDBY-VR Hydraulics | Bosch Rexroth Corp. 7/8

45

= 00

Without coils, but with ring nut and O-Rings for coil fi tting (solution recommended for fl exible stock handling)

= 01

With coils having plug-in pins EN 175301-803, without connectors

= 02

With coils and with connectors non-assembled, type EN 175301-803.

Protection class: IP 65 when connector with seal is properly screwed down, and cable clamp is

correctly tightened.

182-09: Standard

Material No. DescriptionR933002885 182-09 GRAYR933002889 182-09 BLACK

=07

With coils having DEUTSCH DT 04-2P connector, and with bi-directional diode.

Protection class: IP 69 K with female connector properly fi tted (see drawing).

Electric connection (or connections, in case of two solenoids)

Page 55: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBY-VR RA 18300-51/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

46

8/8

Page 56: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-52/10.11

4/3 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

B8_08… (EDBZ)

47

1/10

Summary

Description Page

General specifi cations 1

Ordering details 2

Confi guration 2

Spool variants 3

Principles of operation, cross section 3

Technical Data 4

Δp-Qv characteristic curves 6

Performance limits 6

External Dimensions and Fittings 7

Electric connection 8

General specifications

− Valve elements with 4 ways and 3, or 2, positions

− Control spools directly operated by screwed-in solenoids with extractable coils

− In the de-energized condition, the control spool is held in the central position by return springs.

− Wet pin tubes for DC coils, with push rod for mechanical override; burnish surface treatment

− Coils can be rotated 360° around the tube.

− Manual override (push-button or screw type) available upon request

− Plug-in connectors available: EN 175301-803 (Was DIN 43650); AMP Junior; DT04-2P (Deutsch); free leads

Page 57: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBZ RA 18300-52/10.11

48

2/10

Ordering Details

Configuration

B 8 _ 0 8 _ _ _ _ _ _ _ _ _ _ 0 _

Family Directional valve elements EDB

TypeSize 4

ConfigurationStandardWith secondary valve on AWith ch. for Load Sensing

= 0= 1= 4

Coil type C36

Spool variants 1)

4/3 operated on both sides a and b4/2 operated on side a only

= _ 2 _ _= _ 3 _ _

Votage supply

Without coil = 00

12V DC = OB

13V DC = AD

24V DC = OC

27V DC = AC

48V DC = OD

110V DC = OE

(21.5 DC) 24V AC = OV

(98 DC) 110V AC = OW

(207 DC) 230V AC = OZ

00 01 02 03 04 07 31

Available connections

* Without secondary valve (versions B80__; B84__), the standard confi guration corresponds to “0”.** Additional ports on request.1) The required hydraulic symbol and spool variant can be chosen by consulting page 3.2) Only for confi guration (1) The secondary valves have a maximum fl ow capacity of 6 l/min (1.6 GPM).

0 =P =F =

Optional fittingsStandard emergency

Push-button type emergencyScrew type emergency

0 =1 =2 =

Secondary valves setting 2)

50–210 bar (725–3045 PSI) *100–310 bar (1450–4500 PSI)

25–50 bar (362–725 PSI)

B =Ports**

9/16-18 UNF 2-B (SAE6)

00 =01 =02 =03 =04 =07 =31 =

Electric connectionsWithout coils

With coils, without connectorsWith coils having connectors EN 175301-803

With coils having AMP Junior connectorWith coils having horizontal AMP Junior connectorWith coils having DEUTSCH DT 04-2P connector

With coils and bipolar sheathed lead 350mm (13.8 in) long

A

PT

B A

PT

B

A

PLST

B

= 0 = 1

= 4

Page 58: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-52/10.11 EDBZ Hydraulics | Bosch Rexroth Corp. 3/10

49

A B

Pa a 0 b a 0b

T P T

A B

= A201

= B201

= X301

= Y301

= C201

= E201

= K201

Spool variants

Principles of operation, cross section

The sandwich plate design directional valve elements B8_08… are very compact direct operated solenoid valves which control the start, the stop and the direction of the oil fl ow. These elements basically consist of a stackable housing (1) with a control spool (2), one or two solenoids (5), and one or two return springs (4). When energized, the force of the solenoid (5) pushes the control spool (2) from its neutral-central position “0” to the required end position “a” or “b”, and the required fl ow from P to A (with B to T), or P to

B (with A to T) is achieved. Once the solenoid is de-energized, the return spring (4) pushes the spool thrust washer (3) back against the housing and the spool returns in its neutral-central position.

Each coil is fastened to the solenoid tube by a ring nut (6).

A pin (7) allows to push the spool (2) in emergency conditions, when the solenoid cannot be energized, like in case of voltage shortage.

08 _ 2 _ _ 08 _ 3 _ _

7 6 5 4 3 1 2 3 4 5 6 7

Page 59: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBZ RA 18300-52/10.11

50

4/10

Technical Data (for applications with different specifications consult us)

General

Valve element with 2 solenoids and plug-in pins EN 175301-803 kg (lbs) 1.34 (2.95)

Valve element with 1 solenoids and plug-in pins EN 175301-803 kg (lbs) 1.06 (2.34)

Ambient Temperature °C (°F) –20....+50 (–4....+122) [NBR seals]

Hydraulic

Maximum pressure at P, A, and B ports bar (PSI) 310 (4500)

Maximum dynamic pressure at T bar (PSI) 180 (2610)

Maximum static pressure at T bar (PSI) 210 (3045)

Maximum inlet fl ow l/min (GPM) 25 (6.6)

Maximum inlet fl ow with spool A201 l/min (GPM) 20 (5.3)

Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR seals]

Permissible degree of fl uid contamination ISO 4572: βx≥75 X=12...15ISO 4406: class 20/18/15NAS 1638: class 9

Viscosity range mm2/s 5....420

Electrical

Voltage type DC (AC only with RAC)

Voltage tolerance (nominal voltage) % –10 .... +10

Duty Continuous, with ambient temperature ≤ 50°C (122°F)

Maximum coil temperature °C (°F) 150 (302)

Insulation class H

Compliance with Low Voltage Directive LVD 73/23/EC (2006/95/EC), 2004/108/EC

Coil weight with connection EN 175301-803 kg (lbs) 0.215 (0.44)

Voltage V 12 13 24 27 48 11024

+RAC(21.5)

110+RAC(98)

230+RAC(207)

Voltage type DC DC DC DC DC DC AC AC AC

Power consumption W 26 26 26 26 26 26 29 29 29

Current 1) A 2.15 2.00 1.10 1.00 0.54 0.27 1.20 0.29 0.14

Resistance 2) Ω 5.5 6.5 22 28 89 413 18 338 1430

1) Nominal 2) ± 7% at temperature 20°C [68°F]

Page 60: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-52/10.11 EDBZ Hydraulics | Bosch Rexroth Corp. 5/10

51

Voltage (V) Connector type Coil description Marking Coil Mat no.

=OB 01=OB 02

12 DC EN 175301-803 (Ex. DIN 43650) C3601 12DC 12 DC R933000044

=OB 03 12 DC AMP JUNIOR C3603 12DC 12 DC R933000047

=OB 04 12 DC AMP JUNIOR Horizontal C3604 12DC 12 DC R933002913

=OB 07 12 DC DEUTSCH DT 04-2P C3607 12DC 12 DC R933000048

=OB 31 12 DC Cable 350 mm long C3631 12DC 12 DC R933000045

=AD 01=AD 02

13 DC EN 175301-803 (Ex. DIN 43650) C3601 13DC 13 DC R933000051

=AD 07 13 DC DEUTSCH DT 04-2P C3607 13DC 13 DC R933000049

=OC 01=OC 02

24 DC EN 175301-803 (Ex. DIN 43650) C3601 24DC 24 DC R933000053

=OC 03 24 DC AMP JUNIOR C3603 24DC 24 DC R933000057

=OC 04 24 DC AMP JUNIOR Horizontal C3604 24DC 24 DC R933002914

=OC 07 24 DC DEUTSCH DT 04-2P C3607 24DC 24 DC R933000058

=OC 31 24 DC Cable 350 mm long C3637 24DC 24 DC R933000055

=AC 01=AC 02

27 DC EN 175301-803 (Ex. DIN 43650) C3601 27DC 27 DC R933000056

=AC 07 27 DC DEUTSCH DT 04-2P C3607 27DC 27 DC R933000050

=OD 01=OD 02

48 DC EN 175301-803 (Ex. DIN 43650) C3601 48DC 48 DC R933000059

=OD 04 48 DC AMP JUNIOR Horizontal C3604 48DC 48 DC R933002915

=OE 01=OE 02

110 DC EN 175301-803 (Ex. DIN 43650) C3601 110DC 110 DC R933000061

=OV 01=OV 02

24 RAC EN 175301-803 (Ex. DIN 43650) C3601 21.5DC 21.5 DC R933000054

=OW 01=OW 02

110 RAC EN 175301-803 (Ex. DIN 43650) C3601 98DC 98 DC R933000060

=OZ 01=OZ 02

230 RAC EN 175301-803 (Ex. DIN 43650) C3601 207DC 207 DC R933000062

Page 61: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBZ RA 18300-52/10.11

52

6/10

Performances limits

Characteristic curves

Lowest pressure setting curve for secondary valves

Minimum flow for efficiency of LS control

Measured with hydraulic fl uid ISO-VG32 at 45° ± 5° C (113° ± 9° F); ambient temperature 20° C (68° F).

Measured with the solenoids at their operating temperature, 10% under voltage and without pre-loading of the tank.

Spool VariantCurve No.

P > T P > A P > B A > T B > TB201 3 3 2 2E201 3 3 4 4A201 2 1 1 1 1C201 4 4 4 4 4K201 3 3 4 3X301 2 3 3 2Y301 2 3 3 2

The performance curves are measured with fl ow going across and coming back, like P > A and B > T, with symmetrical fl ow areas.In case of special circuit connections, the performance limits can change.

Spool Variant Curve No.B201 1E201 1A201 4C201 1K201 3X301 1Y301 2

Secondary valve setting Curve No.

50–210 bar (700-2950 PSI) 0

100–310 bar (1400-4500 PSI) 1

25–50 bar (350-700 PSI) 2

0

0

5 10 2515 20

1 2 3 4 5 6 6.6

l/min

GPMFlow Q

290

250

200

150

100

50

PSI20

12

16

8

4

00

34 2 1

Pre

ssur

e Δp

bar

0

0

5 10 2515 20

1 2 3 4 5 6 6.6

l/min

GPMFlow Q

5076

4000

3000

2000

1000

PSI350

150

300250200

10050

00

34 2 1

Pre

ssur

e Δp

bar

0

0

1 2 3 64 5

0.3 0.6 0.9 1.2 1.6

l/min

GPMFlow Q

900

750

600

450

300

150

PSI60

40

50

30

20

10

00

Pre

ssur

e Δp

bar

0

0

1 2 3 64 5

0.3 0.6 0.9 1.2

l/min

GPMFlow Q

900

750

600

450

300

150

PSI60

40

50

30

20

10

00

Pre

ssur

e Δp

bar

1.6

210

Page 62: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-52/10.11 EDBZ Hydraulics | Bosch Rexroth Corp. 7/10

53

External Dimensions and Fittings

1 Solenoid tube hex 22 mm (0.87 inch);torque 20–22 Nm (14.7–16.2 ft-lb).

2 Ring nut for coil locking (OD 20.5 mm); torque 3–4 Nm (2.2–3 ft-lb).

3 Identifi cation label.

4 Clearance needed for connector removal.

5 Optional push-button emergency, EP type, for spool opening: it is pressure stuck to the ring nut for coil locking. Material no. R933000042.

6 Optional screw type emergency, EF type, for spool opening: it is screwed (torque 6-7 [4.4-5.2 ft-lb]) to the tube as replacement of the coil ring nut. Material no. R933006377.

7 Flange specifi cations for coupling to ED intermediate elements.

8 One through hole for coupling of the ED Directional Valve Elements. Recommended tie rod M8 with strength class DIN 8.8. Torque 20–22 Nm (14.7–16.2 ft-lb).

9 O-Rings for P and T ports.

10 Space needed for secondary valve.

11 Plug for 2 positions versions (4/2); hex 22 mm, [0.87 inch].Torque 20-22 Nm [14.7-16.2 ft-lb].

12 A and B ports.

Page 63: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBZ RA 18300-52/10.11

54

8/10

= 00

Without coils, but with ring nut and O-Rings for coil fi tting (solution recommended for fl exible stock handling)

= 01

With coils having plug-in pins EN 175301-803, without connectors

With coils and with connectors non-assembled, type EN 175301-803.Protection class: IP 65 when connector with seal is properly screwed down, and cable clamp is correctly tightened.

= 02

182-09: Standard.182-LED-T-A1: with LED monitoring presence of voltage.182-09-G-DO-2-1: with VDR (Voltage Dependent Resistor), to prevent input voltage over-shootings.

Material No. DescriptionR933002885 182-09 GRAYR933002889 182-09 BLACKR933002893 182-LED-T-A1 12 DC/ACR933002894 182-LED-T-A1 24 DC/ACR933002896 182-LED-T-A1 48 DC/ACR933002897 182-LED-T-A1 110 DC/ACR933002898 182-LED-T-A1 230 DC/ACR933002886 182-09-G-DO-2-1 12DC with VDRR933002887 182-09-G-DO-2-1 24DC with VDR

532-09 RAC: special connectors with rectifi er (RAC) for AC applications.

Material No. DescriptionR933002892 532-09 RAC GRAYR933002891 532-09 RAC BLACK

= 03

With coils having AMP Junior connector, and with bi-directional diode.

Protection class: IP 65 with female connector properly fi tted (see drawing).

= 04

With coils having Horizontal AMP Junior connector, and with bi-directional diode.

Protection class: IP 65 with female connector properly fi tted (see drawing).

= 31

With coils having bi-directional diode and bipolar sheathed free lead, 350 mm long, without pins.

= 07

With coils having DEUTSCH DT 04-2P connector, and with bi-directional diode.

Protection class: IP 69 K with female connector properly fi tted (see drawing).

Electric connection (or connections, in case of two solenoids)

Page 64: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-52/10.11 EDBZ Hydraulics | Bosch Rexroth Corp. 9/10

55

Page 65: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBZ RA 18300-52/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

10/10

56

Page 66: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-53/10.11

4/3 Directional valve elements with or without secondary relief valves, with or without LS connections, and with PO check valves

B8_48… (EDBZ-VR)

57

1/10

Summary

Description Page

General specifi cations 1

Ordering details 2

Confi guration 2

Spool variants 3

Principles of operation, cross section 3

Technical Data 4

Δp-Qv characteristic curves 6

Performance limits 6

External Dimensions and Fittings 7

Electric connection 8

General specifications

− Valve elements with 4 ways and 3 positions.

− Control spools directly operated by screwed-in solenoids with extractable coils.

− In the de-energized condition, the control spool is held in the central position by return springs.

− Wet pin tubes for DC coils, with push rod for mechanical overri-de; burnish surface treatment.

− Single or Dual cross piloted check valves on A and B ports.

− PO checks valves with 4:1 pilot ratio.

− Coils can be rotated 360° around the tube.

− Manual override (push-button or screw type) available upon request.

− Plug-in connectors available: EN 175301-803 (Was DIN 43650); AMP JUNIOR; DT04-2P (Deutsch); free leads.

Page 67: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBZ-VR RA 18300-53/10.11

58

2/10

Ordering Details

Configuration

B 8 _ 4 8 _ _ _ _ _ _ _ _ _ _ _ _

Family Directional valve elements EDB

TypeSize 4

ConfigurationStandardWith secondary valve on AWith ch. for Load Sensing

= 0= 1= 4

Coil type C36

Spool variants 1)

4/3 operated on both sides a and b = _ 2 _ _

Votage supply

Without coil = 00

12V DC = OB

13V DC = AD

24V DC = OC

27V DC = AC

48V DC = OD

110V DC = OE

(21.5 DC) 24V AC = OV

(98 DC) 110V AC = OW

(207 DC) 230V AC = OZ

00 01 02 03 04 07 31

Available connections

1) The required hydraulic symbol and spool variant can be chosen by consulting page 3.2) Only for confi guration (1). The secondary valves have a maximum fl ow capacity of 6 l/min (1.6 GPM).

* Additional ports on request.

0 =P =F =

Optional fittingsStandard emergency

Push-button type emergencyScrew type emergency

1 =3 =

PO check vlave positionCheck valve on port A

Check valve on both ports A and B

3 =2 =0 =1 =

Secondary valves settingWithout secondary valve

25–50 bar (362–725 PSI) 2)

50–210 bar (725–3045 PSI) 2)

100–310 bar (1450–4500 PSI) 2)

B =Ports*

9/16-18 UNF 2-B (SAE6)

00 =01 =02 =

03 =04 =07 =31 =

Electric connectionsWithout coils

With coils, without connectorsWith coils and connectors non-assembled,

type EN 175301-803 With coils having AMP Junior connector

With coils having horizontal AMP Junior connectorWith coils having DEUTSCH DT 04-2P connector

With coils having bi-directional diode and bipolar sheathed cable 350 mm (13.8 in) long

A

PT

B A

PT

B

A

PLST

B

= 0 = 1

= 4

Page 68: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-53/10.11 EDBZ-VR Hydraulics | Bosch Rexroth Corp. 3/10

59

Spool variants

Principles of operation, cross section

The sandwich plate design directional valve elements B8_48… are very compact direct operated solenoid valves which control the start, the stop and the direction of the oil fl ow. These elements basically consist of a stackable housing (1) with a control spool (2), two solenoids (5), and two return springs (4). The upper part of the housing is extended in order to provide space for the cavities where two PO check valves are fi tted. They consist of two calibrated balls (10), with return springs (11), which allow upstream fl ow but lock on the respective seats (9) and prevent the return fl ow. The return fl ow is possible when they are opened by the pilot piston (8), if enough pilot pressure is present in the opposite line.

When energized, the force of the solenoid (5) pushes the control spool (2) from its neutral-central position “0” to the required end position “a” or “b”, and the required fl ow from P to A (with B to T), or P to B (with A to T) is achieved.

Once the solenoid is de-energized, the return spring (4) pushes the spool thrust washer (3) back against the housing and the spool (2) returns in its neutral-central position.

Each coil is fastened to the solenoid tube by a ring nut (6). A pin (7) allows to push the spool (2) in emergency conditions, when the solenoid cannot be energized, like in case of voltage shortage.

A B

Pa a 0 b a 0 bb a b

= B201

= E201

T P T

A B

48 _ 2 ________ 3 48 _ 2 ________ 1

12

7 6 5 4 3 1 2 3 4 5 6 7

11 10 9 8 9 10 11 12

Page 69: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBZ-VR RA 18300-53/10.11

60

4/10

Technical Data (for applications with different specifications consult us)

General

Valve element with 2 solenoids and plug-in pins EN 175301-803 kg (lbs) 1.75 (3.86)

Ambient Temperature °C (°F) –20....+50 (–4....+122) [NBR seals]

Hydraulic

Maximum pressure at P, A, and B ports bar (PSI) 250 (3625)

Maximum dynamic pressure at T bar (PSI) 180 (2610)

Maximum static pressure at T bar (PSI) 210 (3045)

Maximum inlet fl ow l/min (GPM) 20 (5.3)

Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR seals]

Permissible degree of fl uid contamination ISO 4572: βx≥75 X=12...15ISO 4406: class 20/18/15NAS 1638: class 9

Viscosity range mm2/s 5....420

Electrical

Voltage type DC (AC only with RAC)

Voltage tolerance (nominal voltage) % –10 .... +10

Duty Continuous, with ambient temperature ≤ 50°C (122°F)

Maximum coil temperature °C (°F) 150 (302)

Insulation class H

Compliance with Low Voltage Directive LVD 73/23/EC (2006/95/EC), 2004/108/EC

Coil weight with connection EN 175301-803 kg (lbs) 0.215 (0.44)

Voltage V 12 13 24 27 48 11024

+RAC(21.5)

110+RAC(98)

230+RAC(207)

Voltage type DC DC DC DC DC DC AC AC AC

Power consumption W 26 26 26 26 26 26 29 29 29

Current 1) A 2.15 2.00 1.10 1.00 0.54 0.27 1.20 0.29 0.14

Resistance 2) Ω 5.5 6.5 22 28 89 413 18 338 1430

1) Nominal 2) ± 7% at temperature 20°C [68°F]

Page 70: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-53/10.11 EDBZ-VR Hydraulics | Bosch Rexroth Corp. 5/10

61

Voltage (V) Connector type Coil description Marking Coil Mat no.

=OB 01=OB 02

12 DC EN 175301-803 (Ex. DIN 43650) C3601 12DC 12 DC R933000044

=OB 03 12 DC AMP JUNIOR C3603 12DC 12 DC R933000047

=OB 04 12 DC AMP JUNIOR Horizontal C3604 12DC 12 DC R933002913

=OB 07 12 DC DEUTSCH DT 04-2P C3607 12DC 12 DC R933000048

=OB 31 12 DC Cable 350 mm long C3631 12DC 12 DC R933000045

=AD 01=AD 02

13 DC EN 175301-803 (Ex. DIN 43650) C3601 13DC 13 DC R933000051

=AD 07 13 DC DEUTSCH DT 04-2P C3607 13DC 13 DC R933000049

=OC 01=OC 02

24 DC EN 175301-803 (Ex. DIN 43650) C3601 24DC 24 DC R933000053

=OC 03 24 DC AMP JUNIOR C3603 24DC 24 DC R933000057

=OC 04 24 DC AMP JUNIOR Horizontal C3604 24DC 24 DC R933002914

=OC 07 24 DC DEUTSCH DT 04-2P C3607 24DC 24 DC R933000058

=OC 31 24 DC Cable 350 mm long C3637 24DC 24 DC R933000055

=AC 01=AC 02

27 DC EN 175301-803 (Ex. DIN 43650) C3601 27DC 27 DC R933000056

=AC 07 27 DC DEUTSCH DT 04-2P C3607 27DC 27 DC R933000050

=OD 01=OD 02

48 DC EN 175301-803 (Ex. DIN 43650) C3601 48DC 48 DC R933000059

=OD 04 48 DC AMP JUNIOR Horizontal C3604 48DC 48 DC R933002915

=OE 01=OE 02

110 DC EN 175301-803 (Ex. DIN 43650) C3601 110DC 110 DC R933000061

=OV 01=OV 02

24 RAC EN 175301-803 (Ex. DIN 43650) C3601 21.5DC 21.5 DC R933000054

=OW 01=OW 02

110 RAC EN 175301-803 (Ex. DIN 43650) C3601 98DC 98 DC R933000060

=OZ 01=OZ 02

230 RAC EN 175301-803 (Ex. DIN 43650) C3601 207DC 207 DC R933000062

Page 71: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBZ-VR RA 18300-53/10.11

62

6/10

The performance curves are measured with fl ow going across and coming back, like P > A and B > T, with symmetrical fl ow areas.In case of special circuit connections, the performance limits can change.

Performances limits

Characteristic curves

Lowest pressure setting curve for secondary valves

Minimum flow for efficiency of LS control

261 18

12

15

9

3

6

0

200

150

100

50

0

3 2 1

Pre

ssur

e Δp

PSI bar

0

0

5 10 2015

1 2 3 54

l/min

GPMFlow Q

900

750

600

450

300

150

0

PSI60

30

40

50

20

10

0

Pre

ssur

e Δp

bar

0

0

1 2 3 4 5 6

0.3 0.90.6 1.2 1.6

l/min

GPMFlow Q

900

750

600

450

300

150

0

PSI60

30

40

50

20

10

0

Pre

ssur

e Δp

bar

0

0

1 2 3 4 5 6

0.3 0.90.6 1.2 1.6

l/min

GPMFlow Q

012

0

0

5 10 2015

1 2 3 54

l/min

GPMFlow Q

3625

3000

2000

1000

0

Pre

ssur

e Δp

PSI250

200

150

50

100

0

1bar

Measured with hydraulic fl uid ISO-VG32 at 45° ± 5° C (113° ± 9° F); ambient temperature 20° C (68° F).

Measured with the solenoids at their operating temperature, 10% under voltage and without pre-loading of the tank.

Spool VariantCurve No.

P > A P > B A > T B > T

B201 2 2 1 1

E201 2 2 3 3

Spool Variant Curve No.

B201 1

E201 1

Secondary valve setting Curve No.

50–210 bar (700–2950 PSI) 0

100–310 bar (1400–4500 PSI) 1

25–50 bar (350–700 PSI) 2

Page 72: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-53/10.11 EDBZ-VR Hydraulics | Bosch Rexroth Corp. 7/10

63

External Dimensions and Fittings

1 Solenoid tube hex 22 mm [0.87 inch]. Torque 15-16 20–22 Nm [14.6–16.2 lb-ft].

2 Ring nut for coil locking (OD 20.5 mm); torque 3–4 Nm [2.2–3 ft-lb].

3 Identifi cation label.

4 Clearance needed for connector removal.

5 Optional push-button emergency, EP type, for spool opening: it is pressure stuck to the ring nut for coil locking. Material no. R933000042.

6 Optional screw type emergency, EF type, for spool opening: it is screwed (torque 6–7 Nm [4.4–5.2 ft-lb]) to the tube as replacement of the coil ring nut. Material no. R933000021.

7 Flange specifi cations for coupling to ED intermediate elements.

8 One through hole for coupling of the ED Directional Valve Elements. Recommended tie rod M8 with strength class DIN 8.8. Torque 20–22 Nm [14.7–16.2 ft-lb].

9 O-Rings for P and T ports.

10 Space needed for secondary valve, for confi guration 1. Hex. 17, torque 9–10 Nm [6.6–7.4 lb-ft].

11 Plug hex. 6 mm ; torque 30–33 Nm [22–24 ft-lb].

12 A and B ports.

Page 73: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBZ-VR RA 18300-53/10.11

64

8/10

= 00

Without coils, but with ring nut and O-Rings for coil fi tting (solution recommended for fl exible stock handling)

= 01

With coils having plug-in pins EN 175301-803, without connectors

With coils and with connectors non-assembled, type EN 175301-803.Protection class: IP 65 when connector with seal is properly screwed down, and cable clamp is correctly tightened.

= 02

182-09: Standard.182-LED-T-A1: with LED monitoring presence of voltage.182-09-G-DO-2-1: with VDR (Voltage Dependent Resistor), to prevent input voltage over-shootings.

Material No. DescriptionR933002885 182-09 GRAYR933002889 182-09 BLACKR933002893 182-LED-T-A1 12 DC/ACR933002894 182-LED-T-A1 24 DC/ACR933002896 182-LED-T-A1 48 DC/ACR933002897 182-LED-T-A1 110 DC/ACR933002898 182-LED-T-A1 230 DC/ACR933002886 182-09-G-DO-2-1 12DC with VDRR933002887 182-09-G-DO-2-1 24DC with VDR

532-09 RAC: special connectors with rectifi er (RAC) for AC applications.

Material No. DescriptionR933002892 532-09 RAC GRAYR933002891 532-09 RAC BLACK

= 03

With coils having AMP Junior connector, and with bi-directional diode.

Protection class: IP 65 with female connector properly fi tted (see drawing).

= 04

With coils having Horizontal AMP Junior connector, and with bi-directional diode.

Protection class: IP 65 with female connector properly fi tted (see drawing).

= 31

With coils having bi-directional diode and bipolar sheathed free lead, 350 mm long, without pins.

= 07

With coils having DEUTSCH DT 04-2P connector, and with bi-directional diode.

Protection class: IP 69 K with female connector properly fi tted (see drawing).

Electric connection (or connections, in case of two solenoids)

Page 74: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-53/10.11 EDBZ-VR Hydraulics | Bosch Rexroth Corp. 9/10

65

Page 75: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBY-VR RA 18300-53/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

10/10

66

Page 76: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-54/10.11

4/2 Directional valve elements with or without secondary relief valves, with or without LS connections, and with 2/2 solenoid cartridge valve

B8_58… (EDBZ-VEI)

67

1/8

Summary

Description Page

General specifi cations 1

Ordering details 2

Confi guration 2

Spool variants 3

Principles of operation, cross section 3

Technical Data 4

Δp-Qv characteristic curves 6

Performance limits 6

External Dimensions and Fittings 7

Electric connections 8

General specifications

− Valve elements with 4 ways and 2 positions.

− Control spools directly operated by screwed-in solenoids with extractable coils.

− In the de-energized condition, the control spool is held in the central position by return spring.

− Wet pin tubes for DC coils, with push rod for mechanical overri-de; burnish surface treatment.

− Manual override (push-button or screw type) available upon request.

− Additional solenoid cartridge 2/2, NO or NC, single locking or dual locking on port A.

− Plug-in connectors available: EN 175301-803 (Was DIN 43650); DT04-2P (Deutsch); AMP Junior.

Page 77: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBZ-VEI RA 18300-54/10.11

68

2/8

Ordering Details

Configuration

B 8 _ 5 8 E 4 0 1 _ _ _ _ _ _ _ _

FamilyDirectional valve element EDB

TypeSize 4

ConfigurationStandard With secondary valve on AWith ch. for Load Sensing

= 0= 1= 4

Coil typeC36

Spool Variants4/2 operated on side b only

Voltage supply

Without coil = 00

12V DC = OB

24V DC = OC

(21.5 DC) 24V AC = OV

(98 DC) 110V AC = OW

(207 DC) 230V AC = OZ

00 01 02 03 07Available connections

0 =P =F =

Optional fittingsStandard emergency

Push-button type emergencyScrew type emergency

N =C =A =D =O =

Solenoid screw-in cartridge VEIWithout valve 2)

Normally closedNormally open

Double seal, normally closedDouble seal, normally open

0 =1 =2 =3 =

Secondary valve setting50– 210 bar (725–3045 PSI) 1)

100–310 bar (1450– 4500 PSI) 1)

25–50 bar (362–725 PSI) 1)

Without secondary valve

B =Ports *

9/16-18 UNF 2-B (SAE6)

00 =01 =02 =

03 =07 =

Electric connections Without coil

With coil, without connectorWith coil and with connector non-assembled,

type EN 175301-803With coil having AMP Junior connector

With coil having DEUTSCH DT 04-2P connector

1) Only for confi guration (1).

2) The VEI solenoid cartridge must be ordered separately (refer to pages 245 and 249).

The secondary valves have a maximum fl ow capacity of 6 l/min (1.6 GPM).

* Additional ports on request.

= 0 = 1

= 4

Page 78: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-54/10.11 EDBZ-VEI Hydraulics | Bosch Rexroth Corp. 3/8

69

= E401

A B A B A B A B

P

0 b 0 b 0 b 0 bb b b bT P T P T P T

Spool variants

Principles of operation, cross section

The sandwich plate design directional valve elements B8_58… are very compact direct operated solenoid valves which control the start, the direction and the leak free stop the oil fl ow. These elements basically consist of a stackable housing (1) with a control spool (2), one solenoid (5), a spring holder plug (7); two return springs (4); a solenoid screw-in cartridge VEI (8) with its coil (9).

When energized, the force of the solenoid (5) pushes the control spool (2) from its rest position “0” to the end position “b”. If there is a solenoid cartridge VEI (8) type C, A, O, the oil fl ow goes direct-ly to the port A; if there is a solenoid cartridge VEI (8) type D (Dual locking), it is necessary the energize the solenoid cartridge as well in order to allow the oil fl ow to the port A.

Once the solenoid (5) is de-energized, the return spring (4) pushes the spool thrust washer (3) back against the housing and the spool (2) returns in its rest position. The leak free holding at port A is provided by energizing (or de-energizing, if the VEI is NC type) the solenoid cartridge.

By energizing (or de-energizing) the VEI (8) to an open position, the A port is open to tank and downstream fl ow is possible.

The coils are fastened to the respective solenoids (5) and VEI (8) by the ring nuts (6) and (10).

_ _ C _ _ _ A _ _ _ D _ _ _ O _

7 4 3 1 2 3 4 5 6

10 9 8

Page 79: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBZ-VEI RA 18300-54/10.11

70

4/8

Technical Data (for applications with different specifications consult us)

General

Valve element with solenoidand plug-in pins EN 175301-803 kg (lbs) 1.8 (3.96)

Ambient Temperature °C (°F) –20....+50 (–4....+122) [NBR seals]

Hydraulic

Maximum pressure at P, A, and B ports bar (PSI) 310 (4500)

Maximum dynamic pressure at T bar (PSI) 180 (2610)

Maximum static pressure at T bar (PSI) 210 (3045)

Maximum inlet fl ow l/min (GPM) 25 (6.6)

Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR seals]

Permissible degree of fl uid contamination ISO 4572: βx≥75 X=12...15ISO 4406: class 20/18/15NAS 1638: class 9

Viscosity range mm2/s 5....420

Electrical

Voltage type DC (AC only with RAC)

Voltage tolerance (nominal voltage) % –10 .... +10

Duty Continuous, with ambient temperature ≤ 50°C (122°F)

Maximum coil temperature °C (°F) 150 (302)

Insulation class H

Compliance with Low Voltage Directive LVD 73/23/EC (2006/95/EC), 2004/108/EC

Coil weight with connection EN 175301-803 kg (lbs) 0.215 (0.44)

Voltage V 12 2424

+RAC(21.5)

110+RAC(98)

230+RAC(207)

Voltage type DC DC AC AC AC

Power consumption W 26 26 29 29 29

Current 1) A 2.15 1.10 1.20 0.29 0.14

Resistance 2) Ω 5.5 22 18 338 1430

1) Nominal 2) ± 7% at temperature 20°C (68°F)

For the technical data of the VEI coils, please refer to page 265.

Page 80: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-54/10.11 EDBZ-VEI Hydraulics | Bosch Rexroth Corp. 5/8

71

Voltage (V) Connector type Coil description Marking Coil Mat no.

=OB 01=OB 02 12 DC EN 175301-803

(Ex. DIN 43650) C3601 12DC 12 DC R933000044

=OB 03 12 DC AMP JUNIOR C3603 12DC 12 DC R933000047

=OB 07 12 DC DEUTSCH DT 04-2P C3607 12DC 12 DC R933000048

=OC 01=OC 02 24 DC EN 175301-803

(Ex. DIN 43650) C3601 24DC 24 DC R933000053

=OC 03 24 DC AMP JUNIOR C3603 24DC 24 DC R933000057

=OC 07 24 DC DEUTSCH DT 04-2P C3607 24DC 24 DC R933000058

=OV 01=OV 02 24 RAC EN 175301-803

(Ex. DIN 43650) C3601 21.5DC 21.5 DC R933000054

=OW 01=OW 02 110 RAC EN 175301-803

(Ex. DIN 43650) C3601 98DC 98 DC R933000060

=OZ 01=OZ 02 230 RAC EN 175301-803

(Ex. DIN 43650) C3601 207DC 207 DC R933000062

For the technical data of the VEI coils, please refer to page 265.

Page 81: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBZ-VEI RA 18300-54/10.11

72

6/8

The performance curves are measured with fl ow going across and coming back, like P > A and B > T, with symmetrical fl ow areas.In case of special circuit connections, the performance limits can change.

Performances limits

Characteristic curves

Lowest pressure setting curve for secondary valves

Minimum flow for efficiency of LS control

261 18

12

15

9

3

6

0

200

150

100

50

0

2 1

Pre

ssur

e Δp

PSI bar

0

0

5 10 2515 20

1 2 3 4 5 6 6.6

l/min

GPMFlow Q

900

750

600

450

300

150

0

PSI60

30

40

50

20

10

0

Pre

ssur

e Δp

bar

0

0

1 2 3 4 5 6

0.3 0.90.6 1.2 1.6

l/min

GPMFlow Q

900

750

600

450

300

150

0

PSI60

30

40

50

20

10

0

Pre

ssur

e Δp

bar

0

0 1 2 3 4 5 6

0.3 0.90.6 1.2 1.6

l/min

GPMFlow Q

012

1

0

0

5 10 2515 20

1 2 3 4 5 6 6.6

l/min

GPMFlow Q

5076

4000

3000

2000

1000

PSI350

150

300

250

200

100

50

00

Pre

ssur

e Δp

bar

Measured with hydraulic fl uid ISO-VG32 at 45° ± 5° C (113° ± 9° F); ambient temperature 20° C (68° F).

Measured with the solenoids at their operating temperature, 10% under voltage and without pre-loading of the tank.

Secondary valve setting Curve No.

50–210 bar (700–2950 PSI) 0

100–310 bar (1400–4500 PSI) 1

25–50 bar (350–700 PSI) 2

Spool VariantCurve No.

B > T P > A

X301 1 2

Spool Variant Curve No.

X401 1

Page 82: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-54/10.11 EDBZ-VEI Hydraulics | Bosch Rexroth Corp. 7/8

73

External Dimensions and Fittings

1 Solenoid tube hex 24 mm [0.94 inch]. Torque 22-24 Nm [16.2-17.7 lb-ft].

2 Screw-in solenoid cartridge VEI hex 24 mm [0.94 inch].Torque 39-51Nm [28.8-37.6 lb-ft].

3 Ring nut for coil locking (OD 20.5 mm); torque 3-4Nm [2.2-3 ft-lb].

4 Identifi cation label.5 Clearance needed for connector removal.6 Optional push-button emergency, EP type, for spool opening:

it is pressure stuck to the ring nut for coil locking. Mat no. R933000042.

7 Optional screw type emergency, EF type, for spool open-ing: it is screwed (torque 6-7 [4.4-5.2 ft-lb]) to the tube as replacement of the coil ring nut. Mat no. R933006377.

8 Optional emergency control for VEI cartridge: it can be push/pull or screw type. Please refer to the VEI catalogue for details.

9 Flange specifi cations for coupling to ED intermediate ele-ments.

10 One through hole for coupling of the ED Directional Valve Elements. Recommended tie rod M8 with strength class DIN 8.8. Torque 20-22 Nm [14.7-16.2 ft-lb].

11 O-Rings for P and T ports.12 Space needed for secondary valve in confi guration 1.13 A and B ports.

Page 83: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDBZ-VEI RA 18300-54/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

74

8/8

= 00

Without coils, but with ring nut and O-Rings for coil fi tting (solution recommended for fl exible stock handling)

= 01

With coils having plug-in pins EN 175301-803, without connectors

With coils and with connectors non-assembled, type EN 175301-803.Protection class: IP 65 when connector with seal is properly screwed down, and cable clamp is correctly tightened.

= 02

182-09: Standard.182-LED-T-A1: with LED monitoring presence of voltage.182-09-G-DO-2-1: with VDR (Voltage Dependent Resistor), to prevent input voltage over-shootings.

Material No. DescriptionR933002885 182-09 GRAYR933002889 182-09 BLACKR933002893 182-LED-T-A1 12 DC/ACR933002894 182-LED-T-A1 24 DC/ACR933002896 182-LED-T-A1 48 DC/ACR933002897 182-LED-T-A1 110 DC/ACR933002898 182-LED-T-A1 230 DC/ACR933002886 182-09-G-DO-2-1 12DC with VDRR933002887 182-09-G-DO-2-1 24DC with VDR

532-09 RAC: special connectors with rectifi er (RAC) for AC applications.

Material No. DescriptionR933002892 532-09 RAC GRAYR933002891 532-09 RAC BLACK

= 03

With coils having AMP Junior connector, and with bi-directional diode.

Protection class: IP 65 with female connector properly fi tted (see drawing).

= 07

With coils having DEUTSCH DT 04-2P connector, and with bi-directional diode.

Protection class: IP 69 K with female connector properly fi tted (see drawing)

Electric connection (or connections, in case of two solenoids)

Page 84: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-55/10.11

4/3 4/2 Directional valve elements with proportional control and with or without LS connections

B8_80… (EDB-P)

75

1/8

Summary

Description Page

General specifi cations 1

Ordering details 2

Confi guration 2

Spool variants 3

Principles of operation, cross section 3

Technical Data 4

Δp-Qv characteristic curves 5

External Dimensions and Fittings 6

Electric connection 7

Electronic feed regulator 8

General specifications

− Valve element with direct proportional control of spool.

− Control spool operated by screwed-in solenoid with extractable coil.

− In the de-energized condition, the control spool is held in the central position by return springs.

− Wet pin proportional tubes for DC coils, with push rod for mechanical override; nickel plated surface.

− Manual override (push-button or screw type) available upon request.

− Plug-in connectors available: EN 175301-803 (Was DIN 43650), AMP Junior.

Page 85: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDB-P RA 18300-55/10.11

76

2/8

Ordering Details

Configuration

B 8 _ 8 0 _ _ S _ _ _ _ _ _ 0 0 _

1) The required hydraulic symbol and spool variant can be chosen by consulting page 3.

* With Δp (P > T) 10 bar (145 PSI).

** Additional ports on request

Family Directional valve elements EDB

TypeSize 4 proportional

ConfigurationStandard With Load Sensing control

= 0= 4

Coil typeP45

Spool variants 1)

4/3 operated both sides a and b;P – T closed in neutral 4/2 operated on side a only; P – T closed in neutral 4/2 operated on side b only; P – T closed in neutral4/3 operated on both sides a and b; A and B to T in neutral4/2 operated on side a only; A and B to T in neutral4/2 operated on side b only; A and B to T in neutral

= B2

= B3

= B4

= E2

= E3

= E4

Flow patternSymmetrical

Nominal flow*4 l/min (1.06 GPM)9 l/min (2.38 GPM)17 l/min (4.50 GPM)

= 3= 4= 5

0 =F =

Optional fittingsStandard version

Screw type emergency

B =Ports**

9/16-18 UNF 2-B (SAE6)

00 =01 =02 =

03 =

Electric connectionWithout coils

With coils, without connectorsWith coils and with non-assembled con-

nectors, type EN 175301-803 With coils having AMP Junior connector

00 =OB =OC =

Voltage supplyWithout coil

12V DC24V DC

A

P

T

B

A

PLST

B

= 0

= 4

Page 86: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-55/10.11 EDB-P Hydraulics | Bosch Rexroth Corp. 3/8

77

Spool variants

Principles of operation, cross section

The sandwich plate design directional valve elements B8080… are compact direct operated proportional solenoid valves which control the start, the stop, the direction and the quantity of the oil fl ow. These elements basically consist of a stackable housing (1) with a control spool (2), one or two solenoids (5), and one or two return springs (4).

Energized by an electronic feed regulator, each solenoid (5) displaces the control spool (2) from its neutral-central position “0” proportionally to the current received, in open loop mode; a regu-

lated oil fl ow P to A , or P to B, is achieved. Once the solenoid is de-energized, the return spring (4) pushes the spool thrust washer (3) back against the housing and the spool (2) returns in its neutral-central position “0”.

Each coil is fastened to the solenoid tube (5) by a ring nut (6). A pin (7) allows to push the spool (2) in emergency conditions, when the solenoid cannot be energized, like in case of voltage shortage.

A B

Pa a 0 b a 0 0 bb a b

T

A B

P T

A B

P T

= B2

= E2

= B3

= E3

= B4

= E4

= .2 = .3 = .4

7 6 5 4 3 1 2 3 4 5 6 7

Page 87: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDB-P RA 18300-55/10.11

78

4/8

Technical Data (for applications with different specifications consult us)

General

Valve element with 2 solenoids kg (lbs) 1.5 (3.3)

Valve element with 1 solenoids kg (lbs) 1.1 (2.5)

Ambient Temperature °C (°F) –20....+50 (–4....+122) [NBR seals]

Hydraulic

Maximum pressure at P, A, and B ports bar (PSI) 310 (4500)

Maximum dynamic pressure at T bar (PSI) 180 (2610)

Maximum static pressure at T bar (PSI) 210 (3045)

Maximum inlet fl ow l/min (GPM) 24 (6.3)

Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR seals]

Permissible degree of fl uid contamination ISO 4572: βx≥75 X=10...12ISO 4406: class 19/17/14NAS 1638: class 8

Viscosity range mm2/s 20....380 (best 30....46)

Electrical

Voltage type PWM (Power Wave Modulator) best 120 Hz

Voltage tolerance (nominal voltage) % –10 .... +10

Duty Continuous, with ambient temperature ≤ 50°C (122°F)

Maximum coil temperature °C (°F) 150 (302)

Insulation class H

Compliance with Low Voltage Directive LVD 73/23/EC (2006/95/EC), 2004/108/EC

Coil weight with connection EN 175301-803 kg (lbs) 0.228 (0.503)

Voltage V 12 24

Voltage type DC DC

Current 1) A 1.76 0.94

Cool max resistance 2) Ω 3.71 13

Hot max resistance Ω 6.1 22.9

1) Nominal 2) ± 7% at temperature 20°C [68°F]

Voltage (V) Connector type Coil description Marking Coil Mat no.

=OB 01=OB 02 12 DC EN 175301-803

(Ex. DIN 43650) P45 01 12 DC R933000088

=OB 03 12 DC AMP-JUNIOR P45 03 12 DC R933000089

=OC 01=OC 02 24 DC EN 175301-803

(Ex. DIN 43650) P45 01 24 DC R933000090

=OC 03 24 DC AMP-JUNIOR P45 03 24 DC R933000091

Electronic control

Electronic feed regulators (1) Upon request

1) An electronic, open loop type, regulator with plug-in pins EN 175301-803 is available and can be fi tted onto the solenoid directly. For valve elements with two solenoids, two electronic regulators are needed.

Page 88: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-55/10.11 EDB-P Hydraulics | Bosch Rexroth Corp. 5/8

79

Characteristic curves

10

2

1

0

2

3

4

1

0

2

3

4

5

6

7

8

1

0

16

30272421181512

9630

14

12

10

8

6

4

2

0

8

6

4

2

020 30 40 50 60 70 80 90 100

Flow

l/m

in (G

PM

)Fl

ow l/

min

(GP

M)

Flow

l/m

in (G

PM

)

%A

20 30 40 50 60 70 80 90 100%A

20 30 40 50 60 70 80 90 100%A

Ordering code S3: 4 l/min (1.06 GPM) with ∆P 10 bar (145 PSI)

Ordering code S4: 9 l/min (2.38 GPM) with ∆P 10 bar (145 PSI)

Ordering code S5: 17 l/min (4.50 GPM) with ∆P 10 bar (145 PSI)

∆P = 20 bar (290 PSI)

∆P = 10 bar (145 PSI)

∆P = 20 bar (290 PSI)

∆P = 10 bar (145 PSI)

∆P = 20 bar (290 PSI)

∆P = 10 bar (145 PSI)

∆P = is the actual one-way pressure drop across the open spool (inlet pressure minus outlet – port pressure)

The curves refer to the spool fully open

A B

P T

A B

P T

Page 89: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDB-P RA 18300-55/10.11

80

External Dimensions and Fittings

6/8

1 Solenoid tube hex 16 mm (0.63 inch). Torque 20–22 Nm (14.6–16.2 ft-lb).

2 Ring nut for coil locking OD 30 mm (1.18 inch); torque 6–7 Nm (4.4–5.2 ft-lb).

3 Identifi cation label.

4 Dimension with electronic feed regulator.

5 Clearance needed for connector removal.

6 Optional screw type emergency, EF type, for spool opening: it is screwed (torque 6–7 [4.4–5.2 ft-lb]) to the tube as replacement of the coil ring nut. Material no. R933003848.

7 Flange specifi cations for coupling to ED intermediate elements.

8 One through hole for coupling of the ED Directional Valve Elements. Recommended tie rod M8 with strength class DIN 8.8. Torque 20–22 Nm (14.7–16.2 ft-lb).

9 Plug for 2 positions versions (4/2); hex 22 mm, torque 20–22 Nm (14.6–16.2 ft-lb).

10 A and B ports.

Page 90: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18300-55/10.11 EDB-P Hydraulics | Bosch Rexroth Corp. 7/8

81

Electric connection (or connections, in case of two solenoids)

= 00

Without coils, but with ring nut and O-Rings for coil fi tting (solution recommended for fl exible stock handling)

= 01

With coils having plug-in pins DIN 43650 – ISO 4400, without connectors.

Protection class: IP 65 when connector with sealis properly screwed down.

= 02

With coils and with connectors non-assembled, type DIN 43650 – ISO 4400.

Protection class: IP 65 when connector with seal is properly screwed down.

182-09: Standard

Material No. DescriptionR933002885 182-09 GRAYR933002889 182-09 BLACK

=03

With coils having AMP Junior connector, and with bi-directional diode.

Protection class: IP 69 K with female connector properly fi tted (see drawing).

Page 91: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics EDB-P RA 18300-55/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

82

8/8

S UP P L Y

O FF S E T

RA M P UP

RA MP DOW N

FU L L LO A D

CV P 4 H

2 A M E RE

12 2 4V DCC UR R E N T

32

1

Electronic feed regulator (or regulators, in case of two solenoids)

Supply: yellow LED, lit up with power ON.

Off set: minimum current adjustment. Adjust solenoid current so that the desired minimum value is obtained. Clockwise rotation increases current.

Ramp up: Ramping up time adjustment.

Ramp down: Ramping down time adjustment.For longer ramping times, turn potentiometers clockwise; for shorter ramping times, turn the potentiometers counter-clockwise.

Full load current: Maximum current adjustment. Adjust solenoid current so that the desired maximum value is obtained (up to 2A). Clockwise rotation increases current.

Frequency adjustment: it is possible to set the PWM frequency obtaining the desired control sensitivity. After removing the external plastic cover, turn the adjusting screw; clockwise rotation increases frequency from 100 to 500 Hz.

Regulator ordering code R933003290

Supply voltage 12-30 VDC

Control Signal 0-10 VDC

Max. output current 2 A

Minimum output current 0....0.6 A

Ramp adjustment up/down 0.1....10 s

PWM Frequency adjustment (pre-set 120 Hz) 100....500 Hz

Ambient operating temperature -10....+60 °C [14....+140 °F]

Weight 0.12Kg [26.4 lbs]

4 pins connector details R933002888 (Grey)

R933002890 (Black)

Electromagnetic compatibility EN50081-1/2EN61000-4-2/3/4/5/6

Protection class with connector and seal correctly fi tted and properly screwed down.

IP 65 (DIN40050 part 9)

Potentiometer resistance 5....10 κ Ω

Page 92: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-01/10.11

4/3 4/2 Directional valve elements with or without secondary relief valves, with or without LS connections

L8_10… (ED1-Z)

83

1/12

Summary

Description Page

General specifi cations 1

Ordering details 2

Confi guration 2

Spool variants 3

Principles of operation, cross section 4

Technical Data 4

Δp-Qv characteristic curves 6

Performance limits 6

External Dimensions and Fittings 7

Electric connection 10

General specifications

− Valve elements with solenoid operated directional spool.

− Control spools operated by screwed-in solenoids with extractable coils.

− In the de-energized condition, the control spool is held in the central position by return springs.

− Wet pin tubes for DC coils, with push rod for mechanical override; nickel plated surface.

− Coils can be rotated 360° around the tube; they can be energized by AC current through special connectors with rectifi er (RAC).

− Manual override (push-button or screw type) available upon request.

− Plug-in connectors available: EN 175301-803 (Was DIN 43650); AMP Junior; DT04-2P (Deutsch), free leads.

Page 93: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED1-Z RA 18301-01/10.11

84

2/12

Ordering Details

Configuration

L 8 _ 1 0 _ _ _ _ _ _ _ _ _ _ _ _

* Without secondary valves (versions L80__; 84__), the standard confi guration corresponds to “0”

** Additional ports on request

1) The secondary valves have a maximum fl ow capacity of 6 l/min [1.6 gpm]

2) The required hydraulic symbol and spool variant can be chosen by consulting page 3

3) Each different option for the type of emergency chosen implies a specifi c ordering code (refer to page 9)

Family Directional valve elements ED

TypeSize 6

Configuration 1)

StandardWith secondary valve on AWith secondary valve on BWith sec. valve on A and BWith channels for Load Sensing

= 0= 1= 2= 3= 4

Coil type C36

Spool variants 2)

4/3 operated on both sides a and b4/2 operated on side a only4/2 operated on side b onl

= _ 2 _ _= _ 3 __= _ 4 _ _

Votage supply

Without coil = 00

12V DC = OB

13V DC = AD

24V DC = OC

27V DC = AC

48V DC = OD

110V DC = OE

(21.5 DC) 24V AC = OV

(98 DC) 110V AC = OW

(207 DC) 230V AC = OZ

00 01 02 03 04 07 31

Available connections

_ _ =0P =0F =

Optional fittingsLever type emergency 3)

Push-button type emergencyScrew type emergency

0* =1 =2 =3 =

Secondary valves setting50–210 bar (725–3045 PSI)

100–310 bar (1450–4500 PSI)25–50 bar (362–725 PSI)

50–100 bar (725–1450 PSI)

3 =Ports**

3/4-16 UNF 2-B (SAE8)

00 =01 =02 =

03 =04 =

07 =

31 =

Electric connection Without coils

With coils, without connectorsWith coils and with non-assembled connectors, type EN 175301-803

With coils having AMP Junior connectorWith coils having horizontal AMP

Junior connectorWith coils having DEUTSCH

DT 04-2P connectorWith coils and bipolar sheathed lead

350mm [13.8 in] long

= 0 = 4

= 1

= 2

= 3

A

PT

PT

PT

PT

B

A

PLST

B

A B A B

A B

Page 94: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-01/10.11 ED1-Z Hydraulics | Bosch Rexroth Corp. 3/12

85

Spool variants

A B

P

aa 0 b

b

T

= A201

= B201

= C201

= D201

= E201

= K201

= K209

= A401

= B401

= C401

= D401

= E401

= N401

= X401

= Y401

= A301

= B301

= C301

= D301

= E301

= N301

= X301

= Y301

_ 2 _ _

A B

P

0 bb

T

_ 4 _ _

A B

P

aa 0

T

_ 3 _ _

Page 95: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED1-Z RA 18301-01/10.11

86

4/12

Technical Data (for applications with different specifications consult us)

Principles of operation, cross section

The sandwich plate design directional valve elements L8_10… are compact direct operated solenoid valves which control the start, the stop and the direction of the oil fl ow. These elements basically consist of a stackable housing (1) with a control spool (2), one or two solenoids (5), and one or two return springs (4).

When energized, the force of the solenoid (5) pushes the control spool (2) from its neutral-central position “0” to the required end position “a” or “b”, and the required fl ow from P to A (with B to T),

or P to B (with A to T) is achieved. Once the solenoid is de-ener-gized, the return spring (4) pushes the spool thrust washer (3) back against the housing and the spool returns in its neutral-central position.

Each coil is fastened to the solenoid tube by a ring nut (6). A pin (7) allows to push the spool (2) in emergency conditions, when the solenoid cannot be energized, like in case of voltage shortage.

7 6 5 4 3 1 2 3 4 5 6 7

General

Valve element with 2 solenoids kg (lbs) 1.55 (3.42)

Valve element with 1 solenoid kg (lbs) 1.25 (2.76)

Valve element with 2 solenoid with lever override kg (lbs) 1.9 (4.2)

Valve element with 1 solenoid with lever override kg (lbs) 1.6 (3.5)

Ambient Temperature °C (°F) –20....+50 (–4....+122) [NBR seals]

Hydraulic

Maximum pressure at P, A, and B ports bar (PSI) 310 (4500)

Maximum dynamic pressure at T bar (PSI) 180 (2610)

Maximum dynamic pressure,with lever type emergency at T bar (PSI) 100 (1450)

Maximum static pressure at T bar (PSI) 210 (3045)

Maximum inlet fl ow l/min (GPM) 30 (7.9)

Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR seals]

Permissible degree of fl uid contamination ISO 4572: βx≥75 X=12...15ISO 4406: class 20/18/15NAS 1638: class 9

Viscosity range mm2/s 5....420

Page 96: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-01/10.11 ED1-Z Hydraulics | Bosch Rexroth Corp. 5/12

87

Technical Data (for applications with different specifications consult us)

Electrical

Voltage type DC (AC only with RAC)

Voltage tolerance (nominal voltage) % –10 .... +10

Duty Continuous, with ambient temperature ≤ 50°C (122°F)

Maximum coil temperature °C (°F) 150 (302)

Insulation class H

Compliance with Low Voltage Directive LVD 73/23/EC (2006/95/EC), 2004/108/EC

Coil weight with connection EN 175301-803 kg (lbs) 0.215 (0.44)

Voltage V 12 13 24 27 48 11024

+RAC(21.5)

110+RAC(98)

230+RAC(207)

Voltage type DC DC DC DC DC DC AC AC AC

Power consumption W 26 26 26 26 26 26 29 29 29

Current 1) A 2.15 2.00 1.10 1.00 0.54 0.27 1.20 0.29 0.14

Resistance 2) Ω 5.5 6.5 22 28 89 413 18 338 1430

1) Nominal 2) ± 7% at temperature 20°C (68°F)

Voltage (V) Connector type Coil description Marking Coil Mat no.

=OB 01=OB 02 12 DC EN 175301-803

(Ex. DIN 43650) C3601 12DC 12 DC R933000044

=OB 03 12 DC AMP JUNIOR C3603 12DC 12 DC R933000047

=OB 04 12 DC AMP JUNIOR Horizontal C3604 12DC 12 DC R933002913

=OB 07 12 DC DEUTSCH DT 04-2P C3607 12DC 12 DC R933000048

=OB 31 12 DC Cable 350 mm long C3631 12DC 12 DC R933000045

=AD 01=AD 02 13 DC EN 175301-803

(Ex. DIN 43650) C3601 13DC 13 DC R933000051

=AD 07 13 DC DEUTSCH DT 04-2P C3607 13DC 13 DC R933000049

=OC 01=OC 02 24 DC EN 175301-803

(Ex. DIN 43650) C3601 24DC 24 DC R933000053

=OC 03 24 DC AMP JUNIOR C3603 24DC 24 DC R933000057

=OC 04 24 DC AMP JUNIOR Horizontal C3604 24DC 24 DC R933002914

=OC 07 24 DC DEUTSCH DT 04-2P C3607 24DC 24 DC R933000058

=OC 31 24 DC Cable 350 mm long C3637 24DC 24 DC R933000055

=AC 01=AC 02 27 DC EN 175301-803

(Ex. DIN 43650) C3601 27DC 27 DC R933000056

=AC 07 27 DC DEUTSCH DT 04-2P C3607 27DC 27 DC R933000050

=OD 01=OD 02 48 DC EN 175301-803

(Ex. DIN 43650) C3601 48DC 48 DC R933000059

=OD 04 48 DC AMP JUNIOR Horizontal C3604 48DC 48 DC R933002915

=OE 01=OE 02 110 DC EN 175301-803

(Ex. DIN 43650) C3601 110DC 110 DC R933000061

=OV 01=OV 02 24 RAC EN 175301-803

(Ex. DIN 43650) C3601 21.5DC 21.5 DC R933000054

=OW 01=OW 02 110 RAC EN 175301-803

(Ex. DIN 43650) C3601 98DC 98 DC R933000060

=OZ 01=OZ 02 230 RAC EN 175301-803

(Ex. DIN 43650) C3601 207DC 207 DC R933000062

Page 97: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED1-Z RA 18301-01/10.11

88

6/12

Spool VariantCurve No.

P > T P > A P > B A > T B > TA201, A301, A401 3 2 2 1 1X301, X401 4 4 5 5Y301, Y401 4 4 5 5B201, B301, B401 5 5 5 5C201, C301, C401 5 4 4 6 6D201, D301, D401 5 5 4 4E201, E301, E401 4 4 6 6N301, N401 4 4K201, K209 4 4 4 4

Spool Variant Curve No.

A201-A301-A401-B201-B301-B401-X301-X401-Y301-Y401

C201-C301-C401-D201-D301-D401

1

K201-E201-E301-E401 2

N301, N401 3The performance curves are measured with fl ow going across and coming back, like P>A and B>T. With “lever type” emergency control, the performance limits are slightly lower.

Secondary valve setting Curve No.

50–210 bar (700–2950 PSI) 0

100–310 bar (1400–4500 PSI) 1

25–50 bar (350–700 PSI) 2

50–100 bar (700–2950 PSI) 3

Characteristic curves

Performances limits

Minimum flow for efficiency of LS control

Lowest pressure setting curve for secondary valves

261 18

12

15

9

3

6

0

200

150

100

50

0

1

2

3

4

5

6

Pre

ssur

e Δp

PSI bar

0

0

5 10 25 3015 20

1 2 3 4 5 6 7 7.9

l/min

GPMFlow Q

0

0

5 10 25 3015 20

1 2 3 4 5 6 7 7.9

l/min

GPMFlow Q

1

2

3

5076

4000

3000

2000

1000

PSI350

150

300

250

200

100

50

00

Pre

ssur

e Δp

bar

900

750

600

450

300

150

0

PSI60

30

40

50

20

10

0

Pre

ssur

e Δp

bar

0

0

1 2 3 4 5 6

0.3 0.90.6 1.2 1.6

l/min

GPMFlow Q

900

750

600

450

300

150

0 0

PSI60

30

40

50

20

10

Pre

ssur

e Δp

bar

0

0

1 2 3 4 5 6

0.3 0.90.6 1.2 1.6

l/min

GPMFlow Q

123

0

Measured with hydraulic fl uid ISO-VG32 at 45° ± 5° C (113° ± 9° F); ambient temperature 20° C (68° F).

Measured with the solenoids at their operating temperature, 10% under voltage and without pre-loading of the tank.

Page 98: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-01/10.11 ED1-Z Hydraulics | Bosch Rexroth Corp. 7/12

89

External Dimensions and Fittings

1)

3)

2)

8)10)

4) 5)

6)

9)

11) 5)

1 Solenoid tube hex 24 mm (0.94 inch).Torque 22–24 Nm (16.2–17.7 ft-lb).

2 Plug for 2 positions versions (4/2); hex 24 mm. Torque 22–24 Nm (16.2–17.7 ft-lb).

3 Ring nut for coil locking (OD 24 mm);torque 3–4 Nm (2.2–3 ft-lb).

4 Flange specifi cations for coupling to ED intermediate elements with ports SAE 06.

5 Three through holes for coupling of the ED Directional Valve Elements. Recommended tie rods M8 with strength class DIN 8.8. Torque 20–22 Nm (14.7–16.2 ft-lb).

6 Four threaded holes M5 for fi tting a secondary fl angeable element (for elements with SAE 6 ports). Four threaded holes M6 for fi tting a secondary fl angeable element (for elements with SAE 8 ports). Bolts with recommended strength class DIN 8.8: torque 9-12 Nm (6.5-9 ft-lb).

7 A and B ports.

8 O-Rings for P and T ports.

9 Clearance needed for connector removal.

10 Identifi cation label.

11 Flange specifi cations for coupling to ED intermediate elements with ports SAE 08.

Page 99: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED1-Z RA 18301-01/10.11

90

8/12

13)

14)

7)7)

11) 12)

11 Flange specifi cations for coupling to ED intermediate elements.

12 Three through holes for coupling of the ED Directional Valve Elements. Recommended tie rods M8 with strength class DIN 8.8. Torque 20–22 Nm (14.75–16.2 ft-lb).

13 Optional push-button emergency, EP type, for spool opening: it is pressure stuck to the ring nut for coil locking. Material no. R933000042

14 Optional screw type emergency, EF type, for spool opening: it is screwed (torque 6–7 [4.4–5.2 ft-lb]) to the tube as replacement of the coil ring nut. Material no. R933000021.

External Dimensions and Fittings

Page 100: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-01/10.11 ED1-Z Hydraulics | Bosch Rexroth Corp. 9/12

91

2)

1)

3) 4)

5)

6)

External Dimensions and Fittings

1 Ordering Details: HA (if fi tted to side A) or HB (if fi tted to side B)

2 Ordering Details: VA (if fi tted to side A) or VB (if fi tted to side B)

3 Ordering Details: H1 (if fi tted to side A) or H9 (if fi tted to side B)

4 Ordering Details: V1 (if fi tted to side A) or V9 (if fi tted to side B)

5 Ordering Details: XA (if fi tted to side A)or XB (if fi tted to side B)

6 Ordering Details: X1 (if fi tted to side A) or X9 (if fi tted to side B)

Page 101: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED1-Z RA 18301-01/10.11

92

10/12

= 00

Without coils, but with ring nut and O-Rings for coil fi tting (solution recommended for fl exible stock handling)

= 01

With coils having plug-in pins EN 175301-803, without connectors

With coils and with connectors non-assembled, type EN 175301-803.Protection class: IP 65 when connector with seal is properly screwed down, and cable clamp is correctly tightened.

= 02

182-09: Standard.182-LED-T-A1: with LED monitoring presence of voltage.182-09-G-DO-2-1: with VDR (Voltage Dependent Resistor), to prevent input voltage over-shootings.

Material No. DescriptionR933002885 182-09 GRAYR933002889 182-09 BLACKR933002893 182-LED-T-A1 12 DC/ACR933002894 182-LED-T-A1 24 DC/ACR933002896 182-LED-T-A1 48 DC/ACR933002897 182-LED-T-A1 110 DC/ACR933002898 182-LED-T-A1 230 DC/ACR933002886 182-09-G-DO-2-1 12DC with VDRR933002887 182-09-G-DO-2-1 24DC with VDR

532-09 RAC: special connectors with rectifi er (RAC) for AC applications.

Material No. DescriptionR933002892 532-09 RAC GRAYR933002891 532-09 RAC BLACK

= 03

With coils having AMP Junior connector, and with bi-directional diode.

Protection class: IP 65 with female connector properly fi tted (see drawing).

= 04

With coils having Horizontal AMP Junior connector, and with bi-directional diode.

Protection class: IP 65 with female connector properly fi tted (see drawing).

= 31

With coils having bi-directional diode and bipolar sheathed free lead, 350 mm long, without pins.

= 07

With coils having DEUTSCH DT 04-2P connector, and with bi-directional diode.

Protection class: IP 69 K with female connector properly fi tted (see drawing).

Electric connection (or connections, in case of two solenoids)

Page 102: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-01/10.11 ED1-Z Hydraulics | Bosch Rexroth Corp. 11/12

93

Page 103: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED1-Z RA 18301-01/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

12/12

94

Page 104: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-02/10.11

4/3 4/2 Directional valve elements with or without secondary relief valves, with or without LS connections

L8_11… (ED2-DZ)

95

1/10

Summary

Description Page

General specifi cations 1

Ordering details 2

Confi guration 2

Spool variants 3

Principles of operation, cross section 4

Technical Data 4

Δp-Qv characteristic curves 6

Performance limits 6

External Dimensions and Fittings 7

Electric connection 10

General specifications

− Valve elements with solenoid operated directional spool

− Control spools operated by screwed-in solenoids with extracta-ble coils

− In the de-energized condition, the control spool is held in the central position by return springs.

− Wet pin tubes for DC coils, with push rod for mechanical overri-de; nickel plated surface

− Coils can be rotated 360° around the tube; they can be ener-gized by AC current through special connectors with rectifi er (RAC)

− Manual override (push-button or screw type) available upon request

− Plug-in connectors available: EN 175301-803 (Was DIN 43650); AMP Junior; DT04-2P (Deutsch), free leads.

Page 105: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED2-DZ RA 18301-02/10.11

96

2/10

Ordering Details

Configuration

L 8 _ 1 1 _ _ _ _ _ _ _ _ _ _ _ _

* Without secondary valves (versions L80__; L84__), the standard confi guration corresponds to “0”.

** Additional ports on request.

1) The secondary valves, with maximum fl ow capacity of 6 l/min [1.6 gpm].

2) The required hydraulic symbol and spool variant can be chosen by consulting page 3.

3) Each different option for the type of emergency chosen implies a specifi c ordering code (refer to page 9).

= 0 = 4

= 1

= 2

= 3

A

PT

PT

PT

PT

B

A

PLST

B

A B A B

A B

FamilyDirectional Valve elements ED

TypeSize 6

Configuration 1)

StandardWith secondary valve on AWith secondary valve on BWith sec. valves on A and BWith channels for Load Sensing

= 0= 1= 2= 3= 4

Coil type C45

Spool Variants 2)

4/3 operated on both sides a and b4/2 operated on side a only4/2 operated on side b only

= _ 2 _ _= _ 3 _ _= _ 4 _ _= _ 5 _ _

Voltage supply

Without coil = 0012V DC = OB13V DC = AD24V DC = OC27V DC = AC48V DC = OD110V DC = OE(21.5 DC) 24V AC = OV(98 DC) 110V AC = OW(207 DC) 230V AC = OZ

00 01 02 03 07Available connections

_ _ =0P =0F =

Optional fittingsLever type emergency 3)

Push-button type emergencyScrew type emergency

0* =1 =2 =3 =

Secondary valves setting*50–210 bar (725–3045 PSI)

100–310 bar (1450–4500 PSI)25–50 bar (362–725 PSI)

50–100 bar (725–1450 PSI)

3 =Ports**

3/4-16 UNF 2-B (SAE8)

00 =01 =02 =

03 =07 =

Electric connectionWithout coils

With coils, without connectorsWith coils and with non-assembled connectors,

type EN 175301-803.With coils having AMP Junior connectorWith coils having DEUTSCH DT 04-2P

connector

Page 106: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-02/10.11 ED2-DZ Hydraulics | Bosch Rexroth Corp. 3/10

97

Spool variants

A B

Pa a 0 b b

T

= A201

= B201

= C201

= D201

= E201

= F201

= G201

= K201

= U201

= E2R1

= G209

= K209

= A401

= B401

= C401

= D401

= E401

= K401

= T409

= X401

= A301

= B301

= C301

= D301

= E301

= K301

= T301

= X301

= U369

= L201

= M201

= N201

= L501

= N501

= A581

= M501

= A361

= B361

= C361

= D361

= E361

= N301

= T361

= Y301

= A471

= B471

= C471

= D471

= E471

= N401

= T479

= Y401

_ 2 _ _

A B

P

0 b bT

_ 4 _ _

A B

Pa a 0

T

_ 3 _ _

A B

Pa a b b

T

_ 2 _ _

A B

Pa a b b

T

_ 5 _ _

Page 107: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED2-DZ RA 18301-02/10.11

98

4/10

Technical Data (for applications with different specifications consult us)

Principles of operation, cross section

The sandwich plate design directional valve elements L8_11… are compact direct operated solenoid valves which control the start, the stop and the direction of the oil fl ow. These elements basical-ly consist of a stackable housing (1) with a control spool (2), one or two solenoids (5), and one or two return springs (4).

When energized, the force of the solenoid (5) pushes the control spool (2) from its neutral-central position “0” to the required end position “a” or “b”, and the required fl ow from P to A (with B to T),

or P to B (with A to T) is achieved. Once the solenoid is de-ener-gized, the return spring (4) pushes the spool thrust washer (3) back against the housing and the spool returns in its neutral-central position.

Each coil is fastened to the solenoid tube by a ring nut (6). A pin (7) allows to push the spool (2) in emergency conditions, when the solenoid cannot be energized, like in case of voltage shortage.

7 6 5 4 3 1 2 3 4 5 6 7

General

Valve element with 2 solenoids kg (lbs) 1.95 (4.3)

Valve element with 1 solenoid kg (lbs) 1.45 (3.2)

Valve element with 2 solenoid with lever override kg (lbs) 2.2 (4.85)

Valve element with 1 solenoid with lever override kg (lbs) 1.7 (3.75)

Ambient Temperature °C (°F) –20....+50 (–4....+122) [NBR seals]

Hydraulic

Maximum pressure at P, A, and B ports bar (PSI) 310 (4500)

Maximum dynamic pressure at T bar (PSI) 250 (3625)

Maximum dynamic pressure,with lever override at T bar (PSI) 100 (1450)

Maximum static pressure at T bar (PSI) 310 (4500)

Maximum static pressure,with lever override at T bar (PSI) 290 (4200)

Maximum inlet fl ow l/min (GPM) 50 (13.2)

Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR seals]

Permissible degree of fl uid contamination ISO 4572: βx≥75 X=12...15ISO 4406: class 20/18/15NAS 1638: class 9

Viscosity range mm2/s 5....420

Page 108: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-02/10.11 ED2-DZ Hydraulics | Bosch Rexroth Corp. 5/10

99

Technical Data (for applications with different specifications consult us)

Electrical

Voltage type DC (AC only with RAC)

Voltage tolerance (nominal voltage) % –10 .... +10

Duty Continuous, with ambient temperature ≤ 50°C (122°F)

Maximum coil temperature °C (°F) 150 (302)

Insulation class H

Compliance with Low Voltage Directive LVD 73/23/EC (2006/95/EC), 2004/108/EC

Coil weight with connection EN 175301-803 kg (lbs) 0.335 (0.74)

Voltage V 12 13 24 27 48 11024

+RAC(21.5)

110+RAC(98)

230+RAC(207)

Voltage type DC DC DC DC DC DC AC AC AC

Power consumption W 33 31 33 33 33 35 33 33 35

Current 1) A 2.80 2.30 1.40 1.20 0.70 0.32 1.60 0.34 0.16

Resistance 2) Ω 4.24 5.42 17.0 21.8 69.8 341.8 13.6 285.0 1229.0

1) Nominal 2) ± 7% at temperature 20°C (68°F)

Voltage (V) Connector type Code Marking Coil Mat no.

=OB 01=OB 02 12 DC EN 175301-803

(Ex. DIN 43650) C4501 12DC 12 DC R933000026

=OB 03 12 DC AMP JUNIOR C4503 12DC 12 DC R933000027

=OB 07 12 DC DEUTSCH DT 04-2P C4507 12DC 12 DC R933000030

=AD 01=AD 02 13 DC EN 175301-803

(Ex. DIN 43650) C4501 13DC 13 DC R933000028

=AD 03 13 DC AMP JUNIOR C4503 13DC 13 DC R933000029

=AD 07 13 DC DEUTSCH DT 04-2P C4507 13DC 13 DC R933000031

=OC 01=OC 02 24 DC EN 175301-803

(Ex. DIN 43650) C4501 24DC 24 DC R933000034

=OC 03 24 DC AMP JUNIOR C4503 24DC 24 DC R933003630

=OC 07 24 DC DEUTSCH DT 04-2P C4507 24DC 24 DC R933000032

=AC 01=AC 02 27 DC EN 175301-803

(Ex. DIN 43650) C4501 27DC 27 DC R933000035

=AC 03 27 DC AMP JUNIOR C4503 27DC 27 DC R933000036

=AC 07 27 DC DEUTSCH DT 04-2P C4507 27DC 27 DC R933000033

=OD 01=OD 02 48 DC EN 175301-803

(Ex. DIN 43650) C4501 48DC 48 DC R933000037

=OE 01=OE 02 110 DC EN 175301-803

(Ex. DIN 43650) C4501 110DC 110 DC R933000040

=OV 01=OV 02 24 RAC EN 175301-803

(Ex. DIN 43650) C4501 21.5DC 21.5 DC R933000038

=OW 01=OW 02 110 RAC EN 175301-803

(Ex. DIN 43650) C4501 98DC 98 DC R933000039

=OZ 01=OZ 02 230 RAC EN 175301-803

(Ex. DIN 43650) C4501 207DC 207 DC R933000041

Page 109: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED2-DZ RA 18301-02/10.11

100

6/10

The performance curves are measured with fl ow going across and coming back, like P>A and B>T. With “lever type” emergency control, the performance limits are slightly lower.

Characteristic curves

Performances limits

Minimum flow for efficiency of LS control

Lowest pressure setting curve for secondary valves

261 18

12

15

9

3

6

0

200

150

100

50

0

1 2 3 4 5 6

Pre

ssur

e Δp

PSI bar

0

0

5 10 25 504540353015 20

1 2 3 4 5 6 8 9 10 11 127 13.2

l/min

GPMFlow Q

0

0

5 10 25 504540353015 20

1 2 3 4 5 6 8 9 10 11 127 13.2

l/min

GPMFlow Q

5076

4000

3000

2000

1000

PSI350

150

300

250

200

100

50

00

Pre

ssur

e Δp

bar 1 2 3 4

900

750

600

450

300

150

0

PSI60

30

40

50

20

10

0

Pre

ssur

e Δp

bar

0

0

1 2 3 4 5 6

0.3 0.90.6 1.2 1.6

l/min

GPMFlow Q

900

750

600

450

300

150

0

PSI60

30

40

50

20

10

0

Pre

ssur

e Δp

bar

0

0

1 2 3 4 5 6

0.3 0.90.6 1.2 1.6

l/min

GPMFlow Q

1

2

3

0

Measured with hydraulic fl uid ISO-VG32 at 45° ± 5° C (113° ± 9° F); ambient temperature 20° C (68° F).

Measured with the solenoids at their operating temperature, 10% under voltage and without pre-loading of the tank.

Spool Variant Curve No.P > T P > A P > B A > T B > T

A201-A301-A401-A401-A471-A361-G201-G209 2 1 1 1 1

B201-B301-B401-B471-B361-L201-M201-U201-L501-M501 4 4 4 4

C201-C301-C401-C471-C361 6 5 5 6 6D201-D301-D471-D401-D361 6 6 5 5E201-E301-E401-E471-E361-E2R1-T301-T409 5 5 6 6

K201-K209-K301-T361-K401-T479 5 5 3 3X301-X401-Y301-Y401 4 4 4 4N301-N201-N401-F201-U361-N501 4 4

Spool Variant Curve No.A201-A301-A401-A471-A361- C201-C301-C401-C471-C361-G201-G209 - T301- T401-T479- T361

1

B201-B301-B401-B471-B361- D201-D301-D401- D471-D361 -K201-K209-K301-K401

2

X301-X401-Y301-Y401-M201-L201-U201-U369 -E201-E301-E401-E471-E361-E2R1

3

N301-N401-N201-N501-L501-M501-F201 4

Secondary valve setting Curve No.

50–210 bar (700–2950 PSI) 0

100–310 bar (1400–4500 PSI) 1

25–50 bar (350–700 PSI) 2

50–100 bar (700–2950 PSI) 3

Page 110: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-02/10.11 ED2-DZ Hydraulics | Bosch Rexroth Corp. 7/10

101

External Dimensions and Fittings

3) 1)

2)

6) 5)

4) 5)

7)

11) 9)

1 Solenoid tube hex 17 mm (0.7 inch). Torque 22–24 Nm (16.2–17.7 ft-lb).

2 Plug for 2 positions versions (4/2); hex 24 mm, torque 22–24 Nm (16.2–17.7 ft-lb).

3 Ring nut for coil locking (OD 26.5 mm); torque 3–4 Nm (2.2–3 ft-lb).

4 Flange specifi cations for coupling to ED intermediate elements with ports G 3/8 and SAE 6.

5 Three through holes for coupling of the ED Directional Valve Elements. Recommended tie rods M8 with strength class DIN 8.8. Torque 20–22 Nm (14.7–16.2 ft-lb).

6 Flange specifi cations for coupling to ED intermediate elements with ports G 1/2 and SAE 8.

7 Four threaded holes M5 for fi tting a secondary fl angeable element (for elements with SAE 6 ports). Four threaded holes M6 for fi tting a secondary fl angeable element (for elements with SAE 8 ports). Bolts with recommended strength class DIN 8.8: torque 9–12 Nm (6.5–9 ft-lb).

8 A and B ports.

9 O-Rings for P and T ports.

10 Clearance needed for connector removal.

11 Identifi cation label.

Page 111: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED2-DZ RA 18301-02/10.11

102

8/10

External Dimensions and Fittings

15)

12) 13)

14) 13)

16)

8)8)8)8)

12 Flange specifi cations for coupling to the ED intermediate elements with LS channels (for port sizes G 3/8 and SAE6).

13 Three through holes for coupling of the ED Directional Valve Elements. Recommended tie rods M8 with strength class: DIN 8.8. Torque 20–22 Nm (14.7–16.2 ft-lb).

14 Flange specifi cations for coupling to the ED intermediate elements with LS channels (for port sizes G 1/2 and SAE 8)

15 Optional push-button emergency, EP type, for spool opening: it is pressure stuck to the ring nut for coil locking. Material no. R933000043.

16 Optional screw type emergency, EF type, for spool opening: it is screwed (torque 6–7 [4.4–5.2 ft-lb]) to the tube as replacement of the coil ring nut. Material no. R933007215

Page 112: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-02/10.11 ED2-DZ Hydraulics | Bosch Rexroth Corp. 9/10

103

External Dimensions and Fittings

1 Ordering Details: HA (if fi tted to side A) or HB (if fi tted to side B)

2 Ordering Details: VA (if fi tted to side A) or VB (if fi tted to side B)

3 Ordering Details: H1 (if fi tted to side A) or H9 (if fi tted to side B)

4 Ordering Details: V1 (if fi tted to side A) or V9 (if fi tted to side B)

5 Ordering Details: XA (if fi tted to side A)or XB (if fi tted to side B)

6 Ordering Details: X1 (if fi tted to side A) or X9 (if fi tted to side B)

2)

1)

3)

4)

5)

6)

Page 113: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED2-DZ RA 18301-02/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

104

10/10

= 00

Without coils, but with ring nut and O-Rings for coil fi tting (solution recommended for fl exible stock handling)

= 01

With coils having plug-in pins EN 175301-803, without connectors

With coils and with connectors non-assembled, type EN 175301-803.Protection class: IP 65 when connector with seal is properly screwed down, and cable clamp is correctly tightened.

= 02

182-09: Standard.182-LED-T-A1: with LED monitoring presence of voltage.182-09-G-DO-2-1: with VDR (Voltage Dependent Resistor), to prevent input voltage over-shootings.

Material No. DescriptionR933002885 182-09 GRAYR933002889 182-09 BLACKR933002893 182-LED-T-A1 12 DC/ACR933002894 182-LED-T-A1 24 DC/ACR933002896 182-LED-T-A1 48 DC/ACR933002897 182-LED-T-A1 110 DC/ACR933002898 182-LED-T-A1 230 DC/ACR933002886 182-09-G-DO-2-1 12DC with VDRR933002887 182-09-G-DO-2-1 24DC with VDR

532-09 RAC: special connectors with rectifi er (RAC) for AC applications.

Material No. DescriptionR933002892 532-09 RAC GRAYR933002891 532-09 RAC BLACK

= 03

With coils having AMP Junior connector, and with bi-directional diode.

Protection class: IP 65 with female connector properly fi tted (see drawing).

= 07

With coils having DEUTSCH DT 04-2P connector, and with bi-directional diode.

Protection class: IP 69 K with female connector properly fi tted (see drawing).

Electric connection (or connections, in case of two solenoids)

Page 114: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-03/10.11

4/3 4/2 Directional valve elements with soft-shift

L8011… (ED2S-DZ)

105

1/8

Summary

Description Page

General specifi cations 1

Ordering details 2

Confi guration 3

Spool variants 3

Principles of operation, cross section 4

Technical Data 4

Δp-Qv characteristic curves 6

Performance limits 6

External Dimensions and Fittings 7

Electric connection 8

General specifications

− Valve elements with solenoid operated directional spool.

− Switching time adjustment by calibrated orifi ces.

− Control spools operated by screwed-in solenoids with extracta-ble coils.

− In the de-energized condition, the control spool is held in the central position by return springs.

− Wet pin tubes for DC coils, with push rod for mechanical overri-de; nickel plated surface.

− Coils can be rotated 360° around the tube; they can be ener-gized by AC current through special connectors with rectifi er (RAC).

− Manual override (push-button or screw type) available upon request.

− Plug-in connectors available: EN 175301-803 (Was DIN 43650); AMP Junior; DT04-2P (Deutsch), free leads.

Page 115: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED2S-DZ RA 18301-03/10.11

106

2/8

Ordering Details

L 8 0 1 1 _ _ _ _ _ _ _ _ 0 0 _ _

FamilyDirectional valve elements ED

TypeSize 6

ConfigurationStandard

Coil type C45

Spool variants (refer to page 3)With two solenoids, side a and bWith one solenoid, side a only

= _ 2 _ _= _ 3 _ _

Voltage supply

Without coil = 00

12V DC = OB

13V DC = AD

24V DC = OC

27V DC = AC

00 01 02 03 07

Available Connections

_ =F =P =

Emergency operationStandard

Screw type emergencyPush button type emergency

D =

E =G =

Orifice type0.5 mm hole with 0.4 mm wire –

Equivalent to 0.3 mm (0.012 inch) hole 0.4 mm (0.016 inch) hole0.5 mm (0.020 inch) hole

Ports G 3/8 ISO 228

00 =01 =02 =

03 =07 =

Electric connectionWithout coils

With coil, without connectorWith coils and with connectors non-

assembled, type EN 175301-803With coils having AMP Junior connectorWith coils having DEUTSCH DT 04-2P

connector

Page 116: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-03/10.11 ED2S-DZ Hydraulics | Bosch Rexroth Corp. 3/8

107

Spool variants

Configuration

A B

P

a a 0 b b

T

_ 2 _ _

A B

P

a a 0

T

_ 3 _ _

= A201

= B201

= C201

= E201

= A301

= B301

= C301

= E301

= X301

= Y301

Page 117: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED2S-DZ RA 18301-03/10.11

108

4/8

Technical Data (for applications with different specifications consult us)

Principles of operation, cross section

The sandwich plate design directional valve elements L8011… are compact direct operated solenoid valves which control the start, the stop and the direction of the oil fl ow, with the option to adjust the spool switching time. These elements basically consist of a stackable housing (1) with a control spool (2), one or two solenoids (5), and one or two return springs (4).

The spring chambers are connected to the tank port through orifi ces. When energized, the spool (2) travels and oil is pushed to tank from one of the spring chambers: if the cross section of the orifi ces changes, the switching time changes as well. Three orifi ce sizes are available: smaller orifi ce diameter results in longer

switching time, even though the actual time is dependent upon pressure, fl ow and viscosity.

When energized, the force of the solenoid (5) pushes the control spool (2) from its neutral-central position to the required end posi-tion, and the required fl ow from P to A (with B to T), or P to B (with A to T) is achieved. Once the solenoid is de-energized, the return spring (4) pushes the spool thrust washer (3) back against the housing and the spool returns in its neutral-central position.

Each coil is fastened to the solenoid tube by a ring nut (6). A pin (7) allows to push the spool (2) in emergency conditions, when the solenoid cannot be energized, like in case of voltage shortage.

General

Valve element with 2 solenoids kg (lbs) 1.95 (4.3)

Valve element with 1 solenoid kg (lbs) 1.45 (3.2)

Ambient Temperature °C (°F) –20....+50 (–4....+122) [NBR seals]

Hydraulic

Maximum pressure at P, A, and B ports bar (PSI) 310 (4500)

Maximum dynamic pressure at T bar (PSI) 180 (2611)

Maximum static pressure at T bar (PSI) 250 (3626)

Maximum inlet fl ow l/min (GPM) 30 (7.9)

Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR seals]

Permissible degree of fl uid contamination ISO 4572: βx≥75 X=12...15ISO 4406: class 20/18/15NAS 1638: class 9

Viscosity range mm2/s 5....420

Orifi ce sizes available in A position Orifi ce type Ø mm (inch) Code

D 0.3 (0.012) 18-00944

E 0.4 (0.016) 18-0093

G 0.5 (0.020) 18-0094

7 6 5 4 3 A A1 2 3 4 5 6 7

Page 118: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-03/10.11 ED2S-DZ Hydraulics | Bosch Rexroth Corp. 5/8

109

Technical Data (for applications with different specifications consult us)

Electrical

Voltage type DC (AC only with RAC)

Voltage tolerance (nominal voltage) % –10 .... +10

Duty Continuous, with ambient temperature ≤ 50°C (122°F)

Maximum coil temperature °C (°F) 150 (302)

Insulation class H

Compliance with Low Voltage Directive LVD 73/23/EC (2006/95/EC), 2004/108/EC

Coil weight with connection EN 175301-803 kg (lbs) 0.335 (0.74)

Voltage V 12 13 24 27

Voltage type DC DC DC DC

Power consumption W 33 31 33 33

Current 1) A 2.8 2.4 1.4 1.2

Resistance 2) Ω 4.2 5.2 17 21.7

1) Nominal 2) ± 7% at temperature 20°C (68°F)

Voltage (V) Connector type Coil description Marking Coil Mat no.

=OB 01=OB 02 12 DC EN 175301-803

(Ex. DIN 43650) C4501 12DC 12 DC R933000026

=OB 03 12 DC AMP JUNIOR C4503 12DC 12 DC R933000027

=OB 07 12 DC DEUTSCH DT 04-2P C4507 12DC 12 DC R933000030

=AD 01=AD 02 13 DC EN 175301-803 (Ex. DIN

43650) C4501 13DC 13 DC R933000028

=AD 03 13 DC AMP JUNIOR C4503 13DC 13 DC R933000029

=AD 07 13 DC DEUTSCH DT 04-2P C4507 13DC 13 DC R933000031

=OC 01=OC 02 24 DC EN 175301-803 (Ex. DIN

43650) C4501 24DC 24 DC R933000034

=OC 07 24 DC DEUTSCH DT 04-2P C4507 24DC 24 DC R933000032

=AC 01=AC 02 27 DC EN 175301-803 (Ex. DIN

43650) C4501 27DC 27 DC R933000035

=AC 03 27 DC AMP JUNIOR C4503 27DC 27 DC R933000036

=AC 07 27 DC DEUTSCH DT 04-2P C4507 27DC 27 DC R933000033

Page 119: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED2S-DZ RA 18301-03/10.11

110

6/8

Characteristic curves

Performances limits

Measured with hydraulic fl uid ISO-VG32 at 45° ± 5° C (113° ± 9° F); ambient temperature 20° C (68° F).

Measured with the solenoids at their operating temperature, 10% under voltage and without pre-loading of the tank.

362.6 25

20

15

5

10

0

300

200

100

0

Pre

ssur

e Δp

PSI bar

0

0

10 50403020

2 4 6 8 10 12 13.2

l/min

GPMFlow Q

1 2 3 4

Spool VariantCurve No.

P > T P > A P > B A > T B > T

A201, A301 2 1 1 1 1

B201, B301 3 3 3 3

C201, C301 4 3 3 4 4

E201, E301 3 3 4 4

X301, Y301 3 3 3 3

Spool Variant Curve No.

A201, A301 1

B201, B301, C201, C301 2

E201, E301 3

X301, Y301 4

The performance range has been established by employing a 0.3 mm orifi ce. The performance range is wider with larger orifi ces.

The performance curves are measured with fl ow going across and coming back, like P > A and B > T. With “lever type” emer-gency control, the performance limits are slightly lower.

5000 350

250

200

300

150

50

100

0

4000

3000

2000

1000

0

Pre

ssur

e Δp

PSI bar

0

0

10 50403020

2 4 6 8 10 12 13.2

l/min

GPMFlow Q

1 2 34

Page 120: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-03/10.11 ED2S-DZ Hydraulics | Bosch Rexroth Corp. 7/8

111

3)

1) 2)

8)12)

4) 5)

7)

6)

9)

10)11)

External Dimensions and Fittings

1 Solenoid tube hex 17 mm. Torque 22–24 Nm (16.2–17.7 ft-lb).

2 Plug for 2 positions versions (4/2);torque 22–24 Nm (16.2–17.7 ft-lb).

3 Ring nut for coil locking (OD 26,5 mm); torque 5–6 Nm (3.7–4.4 ft-lb).

4 Flange specifi cations for coupling to ED intermediate elements.

5 Three through holes for coupling of the ED Directional Valve Elements. Recommended tie rods M8 with strength class DIN 8.8. Torque 20–22 Nm (14.7–16.2 ft-lb).

6 Four threaded holes M5 for fi tting a secondary fl angeable element. Bolts M5 with recommended strength class DIN 8.8: torque 5–6 Nm (3.6–4.4 ft-lb).

7 A and B ports.

8 O-Rings for P and T ports.

9 Clearance needed for connector removal.

10 Optional push-button, EP type, for emergency spool opening: it is pressure stuck to the ring nut for coil locking. Material no. R933000043.

11 Optional screw type emergency, EF type, for spool opening: it is screwed (torque 6–7 Nm [4.4–5.2 ft-lb]) to the tube as replacement of the coil ring nut. Material no. R933007215.

12 Identifi cation label.

Page 121: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED2S-DZ RA 18301-03/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

112

8/8

Electric connection (or connections, in case of two solenoids)

= 00

Without coils, but with ring nut and O-Rings for coil fi tting (solution recommended for fl exible stock handling)

= 01

With coils having plug-in pins EN 175301-803, without connectors

With coils and with connectors non-assembled, type EN 175301-803.Protection class: IP 65 when connector with seal is properly screwed down and cable clamp is correctly tightened.

= 02

182-09: Standard.182-LED-T-A1: with LED monitoring presence of voltage.182-09-G-DO-2-1: with VDR (Voltage Dependent Resistor), to prevent input voltage over-shootings.

Material No. DescriptionR933002885 182-09 GRAYR933002889 182-09 BLACKR933002893 182-LED-T-A1 12 DC/ACR933002894 182-LED-T-A1 24 DC/ACR933002896 182-LED-T-A1 48 DC/ACR933002897 182-LED-T-A1 110 DC/ACR933002898 182-LED-T-A1 230 DC/ACR933002886 182-09-G-DO-2-1 12DC with VDRR933002887 182-09-G-DO-2-1 24DC with VDR

532-09 RAC: special connectors with rectifi er (RAC) for AC applications.

Material No. DescriptionR933002892 532-09 RAC GRAYR933002891 532-09 RAC BLACK

= 03

With coils having AMP Junior connectorand with bi-directional diode.

Protection class: IP 65 with female connector properly fi tted (see drawing).

= 07

With coils having DEUTSCH DT 04-2P connectorand with bi-directional diode.

Protection class: IP 69 K with female connector properly fi tted (see drawing).

Page 122: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-04/10.11

Directional valve elements with proportional control of tank unloaded excess flow

L808003P… (ED4-PT)

113

1/10

Summary

Description Page

General specifi cations 1

Ordering details 2

Spool variants 2

Principles of operation, cross section 3

Technical Data 4

Δp-Qv characteristic curves 5

External Dimensions and Fittings 6

Electric connection 8

Electronic feed regulator 9

General specifications

− Valve element with direct proportional control of spool.

− Proportional, non pressure compensated, valve element for parti-al or total unloading to Tank of P fl ow.

− Control spool operated by screwed-in solenoids with extractable coils.

− In the de-energized condition, the control spool is held in normal position by return spring.

− Wet pin proportional tubes for DC coils, with push rod for mechanical override; nickel plated surface.

− Manual override (push-button, screw or lever type) available upon request.

− Plug-in connectors available: EN 175301-803 (Was DIN 43650) and DT04-2P (Deutsch).

Page 123: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED4-PT RA 18301-04/10.11

114

2/10

Ordering Details

Configuration

L 8 0 8 0 0 3 P _ _ _ _ _ 0 0 _ _

* With ΔP (P > T) 10 bar (145 PSI).

1) As lever type emergency a choice of options is available and each one implies a specifi c ordering code (refer to page 7).

Family Directional valveelements ED

TypeSize 6, proportional

Coil typeD15

Spool variant2/2 normally open proportional P to T, controlled side a

Nominal flow*12 l/min (3.2 GPM) 18 l/min (4.75 GPM)25 l/min (6.6 GPM)

= 1= 2= 3

_ _ =0P =0F =_ _ =

Optional fittings Without emergency

Push-button type emergencyScrew type emergency

Lever type emergency 1)

00 =01 =02 =

03 =07 =

Electric connectionWithout Coils

With coils, without connectorsWith coils and with non-assembled connectors,

type EN 175301-803With coils having AMP Junior connectorWith coils having DEUTSCH DT 04-2P

connector

00 =Voltage supply

Without coils

OB = 12V DC

OC = 24V DC

31 07 03 02 01

Available connections

P

T

Page 124: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-04/10.11 ED4-PT Hydraulics | Bosch Rexroth Corp. 3/10

115

Example of application

P

M A B A B

T

Principles of operation, cross section

The sandwich plate design valve elements L808003P… are compact direct operated proportional solenoid valves which divert totally or partially the inlet P fl ow to Tank.

These elements basically consist of a stackable housing (1) with a control spool (2), one solenoid (3), and one return spring (4).

With the solenoid de-energized, the return spring (4) keeps the spool (2) in its rest position “0” and all the inlet P fl ow passes through the valve and is unloaded to Tank. When energized by the electronic feed regulator, the solenoid (3) displaces the control

spool (2) from its rest position proportionally to the current recei-ved and proportionally restricts the fl ow area to Tank. A regulated, non pressure compensated, oil fl ow is diverted from P to T and the remaining amount of inlet fl ow in the P line remains available for the downstream operators.

The coil (3) is fastened to the solenoid tube by a ring nut (5). A pin (6) allows to push the spool (2) in emergency conditions, when the solenoid cannot be energized, like in case of voltage shortage.

1 2 4356

Page 125: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED4-PT RA 18301-04/10.11

116

4/10

Technical Data (for applications with different specifications consult us)

General

Valve element with 1 solenoid, pins EN175301-803 kg (lbs) 1.45 (3.2)

Ambient Temperature °C (°F) –20....+50 (–4....+122) [NBR seals]

Hydraulic

Maximum pressure at P, A, and B ports bar (PSI) 310 (4500)

Maximum inlet fl ow l/min (GPM) 28 (7.4)

Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR seals]

Permissible degree of fl uid contamination ISO 4572: βx≥75 X=12...15ISO 4406: class 20/18/15NAS 1638: class 9

Viscosity range mm2/s 5....420

Electrical

Voltage type DC (AC only with RAC)

Voltage tolerance (nominal voltage) % –10 .... +10

Duty Continuous, with ambient temperature ≤ 50°C (122°F)

Maximum coil temperature °C (°F) 150 (302)

Insulation class H

Compliance with Low Voltage Directive LVD 73/23/EC (2006/95/EC), 2004/108/EC

Coil weight with connection EN 175301-803 kg (lbs) 0.335 (0.74)

Voltage V 12 24

Current 1) A 1.76 0.88

Coil resistance 2) – Cold value at 20°C (68°F) Ω 4 16

– Maximum hot value Ω 6.1 24.4

Electronic control

Electronic feed regulators 3) Upon request

1) Nominal 2) ± 7% at temperature 20°C (68°F) 3) An electronic, open loop type, regulator with plug-in pins EN 175301-803 is available and can be fi tted onto the solenoid directly. For valve elements with two solenoids, two electronic regulators are needed.

Voltage (V) Connector type Coil description Marking Coil Mat no.

=OB 01=OB 02 12 DC EN 175301-803

(Ex. DIN 43650) D15 01 12 DC R933000092

=OB 03 12 DC AMP JUNIOR D1530 12 DC R933002877

=OB 07 12 DC DEUTSCH DT 04-2P D15 07 12 DC R933000094

=OC 01=OC 02 24 DC EN 175301-803

(Ex. DIN 43650) D15 01 24 DC R933000093

=OC 07 24 DC DEUTSCH DT 04-2P D15 07 24 DC R933002798

Page 126: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-04/10.11 ED4-PT Hydraulics | Bosch Rexroth Corp. 5/10

117

Characteristic curves

Measured with hydraulic fl uid ISO-VG32 at 45° ± 5° C (113° ± 9° F); ambient temperature 20° C (68° F).

Curve No.

Nominal fl owwith ΔP (P > T)

10 bar (145 PSI)Max fl ow Max pressure

at P

1 12 l/min (3.17 GPM)

14 l/min (3.7 GPM)

310 bar (4500 PSI)

2 18 l/min (4.75 GPM)

20 l/min (5.3 GPM)

310 bar (4500 PSI)

3 25 l/min (6.6 GPM)

28 l/min (7.4 GPM)

310 bar (4500 PSI)

Curve No.

Nominal fl owwith ΔP (P > T)

10 bar (145 PSI)Max fl ow Max pressure

at P

1 12 l/min (3.17 GPM)

14 l/min (3.7 GPM)

310 bar (4500 PSI)

2 18 l/min (4.75 GPM)

20 l/min (5.3 GPM)

310 bar (4500 PSI)

3 25 l/min (6.6 GPM)

28 l/min (7.4 GPM)

310 bar (4500 PSI)

P → T, vs %A = Percentage of the maximum current supplied to the coil

Pressure Drop

7.9

7.0

6.0

5.0

30

20

25

15

5

10

0

4.0

3.0

2.0

1.0

0

3

2

1

Flow

GPM l/min

0 20 40 10060 80 %A

%A = Percentage of the maximum current supplied to the coil.

7.9

7.0

6.0

5.0

30

20

25

15

5

10

0

4.0

3.0

2.0

1.0

0

3

2

1Flow

GPM l/min

0

0

2 4 126 8 10

30 60 90 150 174120

bar

PSIPressure ∆p

Page 127: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED4-PT RA 18301-04/10.11

118

6/10

External Dimensions and Fittings

1 Solenoid tube key.20,4. Torque 22–24 Nm (16.2–17.7 ft-lb).

2 Plug for 2 positions versions; hex 24 mm, torque 22–24 Nm (16.2–17.7 ft-lb).

3 Ring nut for coil locking (OD 30.3 mm [1.18 ln]); torque 6–7 Nm (4.4 – 5.2 ft-lb).

4 Flange specifi cations for coupling to ED intermediate elements.

5 Three through holes for coupling of the ED Directional Valve Elements. Recommended tie rods M8 with strength class DIN 8.8. Torque 20–22 Nm (14.7–16.2 ft-lb).

6 Clearance needed for connector removal.

7 Identifi cation label.

8 Optional push-button emergency, EP type, for spool opening: it is pressure stuck to the ring nut for coil locking. Material no. R933003289.

9 Optional screw type emergency, EF type, for spool opening: it is screwed (torque 6–7 Nm [4.4–5.2 ft-lb]) to the tube as replacement of the coil ring nut. Material no. R933003116.

6)

3)2) 4) 5)

7)8)

9)

1)

Page 128: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-04/10.11 ED4-PT Hydraulics | Bosch Rexroth Corp. 7/10

119

1)

2)

3) 4)

5)

6)

External Dimensions and Fittings

1 Ordering Details: HA (if fi tted to side A) or HB (if fi tted to side B)

2 Ordering Details: VA (if fi tted to side A) or VB (if fi tted to side B)

3 Ordering Details: H1 (if fi tted to side A) or H9 (if fi tted to side B)

4 Ordering Details: V1 (if fi tted to side A) or V9 (if fi tted to side B)

5 Ordering Details: XA (if fi tted to side A)or XB (if fi tted to side B)

6 Ordering Details: X1 (if fi tted to side A) or X9 (if fi tted to side B)

Page 129: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED4-PT RA 18301-04/10.11

120

8/10

Electric connection (or connections, in case of two solenoids)

= 01

With coil having plug-in pins EN 175301-803 – ISO 4400, without connector.Protection class: IP 65 when connector with seal is properly screwed down.

= 02

With coils and with connectors non-assembled, type EN 175301-803 – ISO 4400.Protection class: IP 65 when connector with seal is properly screwed down.

Material No. DescriptionR933002885 182-09 GRAYR933002889 182-09 BLACK

= 03

With coils having AMP Junior connectorand with bi-directional diode.

Protection class: IP 65 with female connector properly fi tted (see drawing).

= 07

With coils having DEUTSCH DT 04-2P connectorand with bi-directional diode.

Protection class: IP 69 K with female connector properly fi tted (see drawing).

Page 130: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-04/10.11 ED4-PT Hydraulics | Bosch Rexroth Corp. 9/10

121

Supply: yellow LED, lit up with power ON.

Off Set: minimum current adjustment. Adjust solenoid current so that the desired minimum value is obtained. Clockwise rotation increases current.

Ramp up: Ramping up time adjustment.

Ramp down: Ramping down time adjustment.For longer ramping times, turn potentiometers clockwise; for shorter ramping times, turn the potentiometers counter-clockwise.

Full load current: Maximum current adjustment. Adjust solenoid current so that the desired maximum value is obtained (up to 2A). Clockwise rotation increases current.

Frequency adjustment: it is possible to set the PWM frequency obtaining the desired control sensitivity. After removing the external plastic cover, turn the adjusting screw; clockwise rotation increases frequency from 100 to 500 Hz.

Electronic feed regulator

Regulator ordering code R933003290

Supply voltage 12-30 VDC

Control Signal 0–10 VDC

Max. output current 2 A

Minimum output current 0....0.6 A

Ramp adjustment up/down 0.1....10 s

PWM Frequency adjustment (pre-set 120 Hz) 100....500 Hz

Ambient operating temperature –10....+60 °C (14....+140 °F)

Weight 0.12 Kg (26.4 lbs)

4 pins connector details R933002888 (Gray)R933002890 (Black)

Electromagnetic compatibility EN50081-1/2EN61000-4-2/3/4/5/6

Protection class with connector and seal correctly fi tted andproperly screwed down.

IP 65 (DIN40050 part 9)

Potentiometer resistance 5....10 k Ω

SU PPLY

OFF SE T

R AM P UP

RA MP DOWN

FU LL LOAD

CV P4−H

2 A M PE RE

2 2 V D CCUR R ENT

32

1

Page 131: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED4-PT RA 18301-04/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

122

10/10

Page 132: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-05/10.11

Directional valve elements with compensated proportional control of Tank unloaded excess flow

L808003C… (ED4-PTC)

123

1/8

Summary

Description Page

General specifi cations 1

Ordering details 2

Spool variants 3

Principles of operation, cross section 3

Technical Data 4

Δp-Qv characteristic curves 5

External Dimensions and Fittings 6

Electric connection 7

Electronic feed regulator 8

General specifications

− Valve element with direct proportional pressure compensated control of inlet, P line, fl ow.

− Three way pressure compensator included.

− Wet pin proportional screwed-in tube for extractable DC coil.

− In the de-energized condition, the control spool is held in normal position by return spring.

− Solenoid tube with push rod for mechanical override; nickel plated surface.

− Manual override (push-button, screw type) available upon request.

− Plug-in connectors available: EN 175301-803 (Was DIN 43650) and DT04-2P (Deutsch).

Page 133: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED4-PTC RA 18301-05/10.11

124

2/8

Ordering Details

* DEUTSCH DT 04-2P available upon request.

Family Directional valveelements ED

TypeSize 6, proportional

Coil typeD15

Spool variantProportional pressure compensatedflow control

Nominal flow10 L/MIN (2.6 GPM)20 l/min (5.3 GPM) 30 l/min (7.9 GPM)40 l/min (10.6 GPM)

= C2= C4= C6= C8

_ _ =0P =0F =

Optional fittings Without emergency

Push-button type emergencyScrew type emergency

00 =01 =02 =

03 =07 =

Electric connectionWithout coils

With coils, without connectorsWith coils and with non-assembled connector,

type EN 175301-803With coils having AMP Junior connectorWith coils having DEUTSCH DT 04-2P

connector*

00 =Voltage supply

Without coils

OB = 12V DC

OC = 24V DC

31 07 03 02 01

Available connections

L 8 0 8 0 0 3 _ _ _ _ _ _ 0 0 _ _

Page 134: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-05/10.11 ED4-PTC Hydraulics | Bosch Rexroth Corp. 3/8

125

Spool variant

Principles of operation, cross section

The sandwich plate design elements L808003C… are 3 way proportional pressure compensated direct solenoid operated valves. They control the inlet (P) fl ow and allow through (out of P1) only the fl ow required by the downstream operators; the excess oil, pressurized at working pressure, is diverted from the inlet P line to Tank. The combination of the proportional regulator with the unloading compensator guarantees stable and constant fl ow, independently from the working pressure.

The proportional control is achieved by a wet pin proportional screwed-in tube, with extractable coil which is energized by an external electronic feed regulator; the electronic regulator performs an “open loop” control of the current supplied to the coil.

These elements basically consist of a stackable housing (1) with a control spool (2), a solenoid (3), and one return spring (4); additio-nally there is a compensator (6), with a preset spring (7), a spring retainer plug (8) and a drain orifi ce (9). A coil (5) is held to the solenoid tube by the ring nut (10).

With the solenoid de-energized, the spool stays in the closed position; the pressure overcomes the compensator spring (7) and the inlet (P) oil is unloaded to Tank at the p value shown by the characteristic curve. Pressure at (P1) is drained to Tank through the orifi ce and drops to zero.

By energizing the solenoid (3) through the electronic feed regulator, the control spool (2) is displaced from its rest position proportio-nally to the current; the corresponding opening allows a pressure compensated fl ow to proceed to P1, while the excess fl ow is diverted to Tank.

With the solenoid (3) de-energized, the return spring (4) pushes the spool (2) to its rest position “0” fully closed. No fl ow goes to P1 and any residual pressure at P1 is drained through the orifi ce. The compensator (6) is pushed fully open all the oil is unloaded to Tank.

P P1

T T

1243510 9 6 7 8

Page 135: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED4-PTC RA 18301-05/10.11

126

4/8

Technical Data (for applications with different specifications consult us)

General

Valve element with 1 solenoid kg (lbs) 1.53 (3.37)

Ambient Temperature °C (°F) –20....+50 (–4....+122) [NBR seals]

Hydraulic

Maximum pressure at P bar (PSI) 250 (3625)

Maximum fl ow rated at P1 l/min (GPM) 40 (10.6)

Maximum inlet fl ow l/min (GPM) 50 (13.2)

Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR seals]

Permissible degree of fl uid contamination ISO 4572: βx≥75 X=12...15ISO 4406: class 20/18/15NAS 1638: class 9

Viscosity range mm2/s 20....380 (optimal 30....46)

Electrical

Voltage type PWM Power wave modulation pre-set at 120 Hz

Voltage tolerance (nominal voltage) % –10 .... +10

Duty Continuous, with ambient temperature ≤ 50°C (122°F)

Maximum coil temperature °C (°F) 150 (302)

Insulation class H

Compliance with Low Voltage Directive LVD 73/23/EC (2006/95/EC), 2004/108/EC

Coil weight kg (lbs) 0.335 (0.74)

Voltage V 12 24

Current 1) A 1.76 0.88

Coil resistance 2) – Cold value at 20°C (68°F) Ω 4 16

– Maximum hot value Ω 6.1 24.4

Electronic control

Electronic feed regulators 3) Upon request

Voltage (V) Connector type Coil description Marking Coil Mat no.

=OB 01=OB 02 12 DC EN 175301-803

(Ex. DIN 43650) D15 01 12 DC R933000092

=OB 03 12 DC AMP JUNIOR D1530 12 DC R933002877

=OB 07 12 DC DEUTSCH DT 04-2P D15 07 12 DC R933000094

=OC 01=OC 02 24 DC EN 175301-803

(Ex. DIN 43650) D15 01 24 DC R933000093

=OC 07 24 DC DEUTSCH DT 04-2P D15 07 24 DC R933002798

1) Nominal 2) ± 7% at temperature 20°C (68°F) 3) An electronic, open loop type, regulator with plug-in pins EN 175301-803 is available and can be fi tted onto the solenoid directly. For valve elements with two solenoids, two electronic regulators are needed.

Page 136: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-05/10.11 ED4-PTC Hydraulics | Bosch Rexroth Corp. 5/8

127

Characteristic curves

0

0

10 50403020

2 4 6 8 10 12 13.2

l/min

GPMFlow Q

217.5 15

2 1

12

9

3

6

0

200

150

100

50

0

Pre

ssur

e ∆p

PSI bar

0 20 100806040 %A

13.2 50

40

30

10

20

0

12

10

8

6

4

2

0

Flow

Q

GPM l/min

0

0

50 250200150100

1000 2000 3000 3625

bar

PSIPressure ∆p

13.2 50

40

30

10

20

0

12

10

8

6

4

2

0

o

GPM l/min

Flow

Q

0

0

50 250200150100

1000 2000 3000 3625

bar

PSIPressure ∆p

0.264 1.00

0.75

0.50

0.25

0

0.20

0.25

0.15

0.10

0.05

0

l Q

GPM l/min

Flow

Q

Compensated flow curves

Drain to tank

Nominal Flow Curve No.

C2 – C4 – C6 1

C8 2

Nominal Flow Curve No.

C2 1

C4 2

C6 3

C8 4

Page 137: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED4-PTC RA 18301-05/10.11

128

6/8

External Dimensions and Fittings

6)

3) 1)2)

7)

8)

9)

4) 5)

1 Solenoid tube key 21. Torque 22–24 Nm (16.2–17.7 ft-lb).

2 Plug for spring housing hex 24 mm, torque 22–24 Nm (16.2–17.7 ft-lb).

3 Ring nut for coil locking (OD 30.3 mm [1.18 in.]); torque 6–7 Nm (4.4 – 5.2 ft-lb).

4 Flange specifi cations for coupling to ED intermediate elements.

5 Three through holes for coupling of the ED Directional Valve Elements. Recommended tie rods M8 with strength class DIN 8.8. Torque 20–22 Nm (14.7–16.2 ft-lb).

6 Clearance needed for connector removal.

7 Identifi cation label.

8 Optional push-button emergency, EP type, for spool opening: it is pressure stuck to the ring nut for coil locking. Material no. R933003289.

9 Optional screw type emergency, EF type, for spool opening: it is screwed (torque 6-7 [4.4-5.2 ft-lb]) to the tube as replace-ment of the coil ring nut. Mat no. R933003116.

Page 138: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-05/10.11 ED4-PTC Hydraulics | Bosch Rexroth Corp. 7/8

129

Electric connection (or connections, in case of two solenoids)

= 01

With coil having plug-in pins EN 175301-803 – ISO 4400, without connector.Protection class: IP 65 when connector with seal is properly screwed down.

= 02

With coils and with connectors non-assembled, type EN 175301-803 – ISO 4400.Protection class: IP 65 when connector with seal is properly screwed down.

Material No. DescriptionR933002885 182-09 GRAYR933002889 182-09 BLACK

= 03

With coils having AMP Junior connectorand with bi-directional diode.

Protection class: IP 65 with female connector properly fi tted (see drawing).

= 07

With coils having DEUTSCH DT 04-2P connectorand with bi-directional diode.

Protection class: IP 69 K with female connector properly fi tted (see drawing).

Page 139: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED4-PTC RA 18301-05/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

130

8/8

Supply: yellow LED, lit up with power ON.

Off Set: minimum current adjustment. Adjust solenoid current so that the desired minimum value is obtained. Clockwise rotation increases current.

Ramp up: Ramping up time adjustment.

Ramp down: Ramping down time adjustment.For longer ramping times, turn potentiometers clockwise; for shorter ramping times, turn the potentiometers counter-clockwise.

Full load current: Maximum current adjustment. Adjust solenoid current so that the desired maximum value is obtained (up to 2A). Clockwise rotation increases current.

Frequency adjustment: it is possible to set the PWM frequency obtaining the desired control sensitivity. After removing the external plastic cover, turn the adjusting screw; clockwise rotation increases frequency from 100 to 500 Hz.

Electronic feed regulator

Regulator ordering code R933003290

Supply voltage 12-30 VDC

Control Signal 0–10 VDC

Max. output current 2 A

Minimum output current 0....0.6 A

Ramp adjustment up/down 0.1....10 s

PWM Frequency adjustment (pre-set 120 Hz) 100....500 Hz

Ambient operating temperature –10....+60 °C (14....+140 °F)

Weight 0.12 Kg (26.4 lbs)

4 pins connector details R933002888 (Gray)R933002890 (Black)

Electromagnetic compatibility EN50081-1/2EN61000-4-2/3/4/5/6

Protection class with connector and seal correctly fi tted andproperly screwed down.

IP 65 (DIN40050 part 9)

Potentiometer resistance 5....10 k Ω

SU PPLY

OFF SE T

R AM P UP

RA MP DOWN

FU LL LOAD

CV P4−H

2 A M PE RE

12 2 4 V D CCUR R ENT

32

1

Page 140: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-06/10.11

4/3 4/2 Directional valve elements with proportional control and with or without LS connections

L8_80… (ED4-P)

131

1/10

Summary

Description Page

General specifi cations 1

Ordering details 2

Confi guration 2

Spool variants 3

Principles of operation, cross section 3

Technical Data 4

Δp-Qv characteristic curves 5

External Dimensions and Fittings 6

Electric connections 8

Electronic feed regulators 9

General specifications

− Valve element with direct proportional control of spool

− Control spool operated by screwed-in solenoid with extractable coil

− In the de-energized condition, the control spool is held in the central position by return springs.

− Wet pin proportional tubes for DC coils, with push rod for mechanical override; nickel plated surface

− Manual override (push-button or screw type) available upon request

− Plug-in connectors available: EN 175301-803 (Was DIN 43650) and DT04-2P (Deutsch)

Page 141: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED4-P RA 18301-06/10.11

132

2/10

Ordering Details

* With ∆p (P > T) 10 bar (145 PSI).

Configurations

L 8 _ 8 0 _ _ S _ _ _ _ _ _ 0 _ _

1) The required hydraulic symbol and spool variant can be chosen by consulting page 3.2) Each different option for the type of emergency chosen implies a specifi c ordering code (refer to page 7).

Family Directional valve elements ED

TypeSize 6, proportional

ConfigurationsStandard With Load Sensing control

= 0= 4

Coil typeD15

Spool variants 1)

4/3 operated both sides a and b; P – T closed in neutral4/2 operated on side a only; P – T closed in neutral4/2 operated on side b only; P – T closed in neutraL4/3 operated on both sides a and b; A and B to T in neutraL4/2 operated on side a only; A and B to T in neutral4/2 operated on side b only; A and B to T in neutral

= B2

= B3

= B4

= E2

= E3

= E4

Flow patternSymmetrical

Nominal flow *10 l/min (2.64 GPM)20 l/min (5.28 GPM)30 l/min (7.9 GPM)

= 2= 4=6

_ _ =0F =0P =_ _ =

Optional fittings Without emergency

Screw type emergency Push-button type emergency

Lever type emergency 2)

3 =Ports

3/4-16 UNF 2-B (SAE8)

00 =01 =02 =

03 =07 =

Electric connectionWithout coils

With coils, without connectorsWith coils and with non-assembled connector,

type EN 175301-803With coils having AMP Junior connectorWith coils having DEUTSCH DT 04-2P

connector*

00 =Voltage supply

Without coils

OB = 12V DC

OC = 24V DC

07 03 02 01

Available connections

A

P

T

B

A

PLST

B

= 0

= 4

Page 142: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-06/10.11 ED4-P Hydraulics | Bosch Rexroth Corp. 3/10

133

Spool variant

Principles of operation, cross section

= B2

A B

Pa b

T

= B4

= B3

= E2

= E4

= E3

A B

Pb

T

A B

Pa

T

A B

Pa b

T

A B

Pb

T

A B

Pa

T

The sandwich plate design directional valve elements L8080… are compact direct operated proportional solenoid valves which control the start, the stop, the direction and the quantity of the oil fl ow. These elements basically consist of a stackable housing (1) with a control spool (2), one or two solenoids (3), and one or two return springs (4).

Energized by an electronic feed regulator, each solenoid (3) displaces the control spool (2) from its neutral-central position “0”

proportionally to the current received; a regulated oil fl ow P to A , or P to B, is achieved. Once the solenoid is de-energized, the return spring (4) pushes the spool thrust washer (5) back against the housing and the spool returns in its neutral-central position.

Each coil (3) is fastened to the solenoid tube by a ring nut (6). A pin (7) allows to push the spool (2) in emergency conditions, when the solenoid cannot be energized, like in case of voltage shortage.

1 24 43 35 56 67 7

Page 143: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED4-P RA 18301-06/10.11

134

4/10

Technical Data (for applications with different specifications consult us)

General

Valve element with 2 solenoids kg (lbs) 2.20 (4.85)

Valve element with 1 solenoid kg (lbs) 1.70 (3.75)

Ambient Temperature °C (°F) –20....+50 (–4....+122) [NBR seals]

Hydraulic

Maximum pressure at P bar (PSI) 250 (3625)

Maximum dynamic pressure at T bar (PSI) 210 [3050]

Maximum static pressure at T bar (PSI) 250 [3625]

Maximum inlet fl ow l/min (GPM) 45 (11.9)

Nominal fl ow with DP = 10 bar (145 PSI) l/min (GPM) 10, 20, 30 (2.64, 5.28, 7.9)

Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR seals]

Permissible degree of fl uid contamination ISO 4572: βx≥75 X=12...15ISO 4406: class 20/18/15NAS 1638: class 9

Viscosity range mm2/s 20....380 (optimal 30....46)

Electrical

Voltage type PWM Power wave modulation pre-set at 120 Hz

Voltage tolerance (nominal voltage) % –10 .... +10

Duty Continuous, with ambient temperature ≤ 50°C (122°F)

Maximum coil temperature °C (°F) 150 (302)

Insulation class H

Compliance with Low Voltage Directive LVD 73/23/EC (2006/95/EC), 2004/108/EC

Coil weight kg (lbs) 0.335 (0.74)

Voltage V 12 24

Current 1) A 1.76 0.88

Coil resistance 2) – Cold value at 20°C (68°F) Ω 4 16

– Maximum hot value Ω 6.1 24.4

Electronic control

Electronic feed regulators 3) Upon request

Voltage (V) Connector type Coil description Marking Coil Mat no.

=OB 01=OB 02 12 DC EN 175301-803

(Ex. DIN 43650) D15 01 12 DC R933000092

=OB 03 12 DC AMP JUNIOR D1530 12 DC R933002877

=OB 07 12 DC DEUTSCH DT 04-2P D15 07 12 DC R933000094

=OC 01=OC 02 24 DC EN 175301-803

(Ex. DIN 43650) D15 01 24 DC R933000093

=OC 07 24 DC DEUTSCH DT 04-2P D15 07 24 DC R933002798

1) Nominal 2) ± 7% at temperature 20°C (68°F) 3) An electronic, open loop type, regulator with plug-in pins EN 175301-803 is available and can be fi tted onto the solenoid directly. For valve elements with two solenoids, two electronic regulators are needed.

Page 144: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-06/10.11 ED4-P Hydraulics | Bosch Rexroth Corp. 5/10

135

Characteristic curves

Measured with hydraulic fl uid ISO-VG32 at 45° ± 5° C [113° ± 9° F]; ambient temperature 20° C [68° F].

307.9

7

6

5

4

3

2

1

0

4

6

8

10

12

14

15.8

2

0

60

50

40

30

20

10

0

25

20

15

10

5

0

Flow

Q –

l/m

in (G

PM

)

307.9

7

6

5

4

3

2

1

0

25

20

15

10

5

0

Flow

Q –

l/m

in (G

PM

)Fl

ow Q

– l/

min

(GP

M)

Ordering code 2: 10 l/min (2.64 GPM) with ∆P 10 bar (145 PSI)

∆P = 20 bar (290 PSI)

∆P = 10 bar (145 PSI)

∆P = 20 bar (290 PSI)

∆P = 10 bar (145 PSI)

∆P = 20 bar (290 PSI)

∆P = 10 bar (145 PSI)

∆P = is the actual one-way pressure drop across the open spool (inlet pressure minus outlet – port pressure)

0 20 40 60 80 100%A

20 30 40 50 60 70 80 90 100%A

20 30 40 50 60 70 80 90 100%A

The curves refer to the spool fully open

A B

P T

A B

P T

Ordering code 4: 20 l/min (5.28 GPM) with ∆P 10 bar (145 PSI)

Ordering code 6: 30 l/min (7.92 GPM) with ∆P 10 bar (145 PSI)

Page 145: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED4-P RA 18301-06/10.11

136

6/10

External Dimensions and Fittings

1 Solenoid tube key 21 mm. Torque 22–24 Nm (16.2–17.7 ft-lb).2 Plug for 2 positions versions (4/2); hex 24 mm,

torque 22–24 Nm (16.2–17.7 ft-lb).3 Ring nut for coil locking (OD 30 mm);

torque 6–7 Nm (4.4–5.2 ft-lb).4 Flange specifi cations for coupling to ED intermediate elements

with ports G 3/8 and SAE 6.5 Three through holes for coupling of the ED Directional Valve

Elements. Recommended tie rods M8 with strength class DIN 8.8. Torque 20–22 Nm (14.7–16.2 ft-lb).

6 Clearance needed for connector removal.7 A and B ports.8 Identifi cation label.

9 Optional push-button emergency, EP type, for spool opening: it is pressure stuck to the ring nut for coil locking. Material no. R933003289.

10 Optional screw type emergency, EF type, for spool opening: it is screwed (torque 6–7 [4.4–5.2 ft-lb]) to the tube as replacement of the coil ring nut. Material no. R933003116.

11 Four threaded holes M5 for fi tting a secondary fl angeable element (for elements with SAE 6 ports). Four threaded holes M6 for fi tting a secondary fl angeable element (for elements with SAE 8 ports). Bolts with recommended strength class DIN 8.8: torque 9–12 Nm (6.5–9 ft-lb).

12 Flange specifi cations for coupling to ED intermediate elements with ports G 1/2 and SAE 8.

Page 146: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-06/10.11 ED4-P Hydraulics | Bosch Rexroth Corp. 7/10

137

External Dimensions and Fittings

1)

2)

3) 4)

5)

6)

1 Ordering Details: HA (if fi tted to side A) or HB (if fi tted to side B)

2 Ordering Details: VA (if fi tted to side A) or VB (if fi tted to side B)

3 Ordering Details: H1 (if fi tted to side A) or H9 (if fi tted to side B)

4 Ordering Details: V1 (if fi tted to side A) or V9 (if fi tted to side B)

5 Ordering Details: XA (if fi tted to side A) or XB (if fi tted to side B)

6 Ordering Details: X1 (if fi tted to side A) or X9 (if fi tted to side B)

Page 147: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED4-P RA 18301-06/10.11

138

8/10

Electric connection (or connections, in case of two solenoids)

= 01

With coil having plug-in pins DIN 43650 – ISO 4400, without connector.Protection class: IP 65 when connector with seal is properly screwed down.

= 02

With coils and with connectors non-assembled, type DIN 43650 – ISO 4400.

Protection class: IP 65 when connector with seal is properly screwed down.

Material No. DescriptionR933002885 182-09 GRAYR933002889 182-09 BLACK

= 03

With coils having AMP Junior connectorand with bi-directional diode.

Protection class: IP 65 with female connector properly fi tted (see drawing).

= 07

With coils having DEUTSCH DT 04-2P connector.Protection class: IP 69 K with female connector

properly fi tted (see drawing).

Page 148: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-06/10.11 ED4-P Hydraulics | Bosch Rexroth Corp. 9/10

139

Supply: yellow LED, lit up with power ON.

Off Set: minimum current adjustment. Adjust solenoid current so that the desired minimum value is obtained. Clockwise rotation increases current.

Ramp up: Ramping up time adjustment.

Ramp down: Ramping down time adjustment.For longer ramping times, turn potentiometers clockwise; for shorter ramping times, turn the potentiometers counter-clockwise.

Full load current: Maximum current adjustment. Adjust solenoid current so that the desired maximum value is obtained (up to 2A). Clockwise rotation increases current.

Frequency adjustment: it is possible to set the PWM frequency obtaining the desired control sensitivity. After removing the external plastic cover, turn the adjusting screw; clockwise rotation increases frequency from 100 to 500 Hz.

Electronic feed regulator

Regulator ordering code R933003290

Supply voltage 12-30 VDC

Control Signal 0–10 VDC

Max. output current 2 A

Minimum output current 0....0.6 A

Ramp adjustment up/down 0.1....10 s

PWM Frequency adjustment (pre-set 120 Hz) 100....500 Hz

Ambient operating temperature –10....+60 °C (14....+140 °F)

Weight 0.12 Kg (26.4 lbs)

4 pins connector details R933002888 (Gray)R933002890 (Black)

Electromagnetic compatibility EN50081-1/2EN61000-4-2/3/4/5/6

Protection class with connector and seal correctly fi tted andproperly screwed down.

IP 65 (DIN40050 part 9)

Potentiometer resistance 5....10 k Ω

SU PPLY

OFF SE T

R AM P UP

RA MP DOWN

FU LL LOAD

CV P4−H

2 A M PE RE

2 2 V D CCUR R ENT

32

1

Page 149: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED4-P RA 18301-06/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

140

10/10

Page 150: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

4/3 4/2 Directional valve elements with proportional hydraulic control and with or without LS connections

L8_P5… (ED-IP)

141

RA 18301-07/10.11 1/6

Summary

Description Page

General specifi cations 1

Ordering details 2

Confi gurations 2

Spool variants 3

Principles of operation, cross section 3

Technical Data 4

Δp-Qv characteristic curves 5

External Dimensions and Fittings 6

General specifications

− Valve element 4 ways, 3 positions.

− Hydraulically direct operated spool.

− Hydraulic operating element bolted on.

− Hydraulic operating element available with inlet port: G1/4 DIN 3852; 9/16-18 UNF 2-B.

− The control spool is held in the central position by return springs.

Page 151: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED-IP RA 18301-07/10.11

142

2/6

Ordering Details

Spool variant

Configurations

L 8 _ P 5 _ _ S _ 0 0 0 0 _ 0

1) Refer to page 3 for the selection of the hydraulic symbol and circuit features.

* Without secondary valves (versions L80__; L84__), the standard confi guration corresponds to “0”.

** Additional ports on request.

FamilyDirectional Valves elements ED

TypeSize 6

Configuration*Standard = 0With LS channels = 4

= 0= 4

Operation typeDirect hydraulic proportional

Spool Variants 1)

4/3 operated both sides a and b; P – T closed in neutral4/3 operated both sides a and b; A and B to T in neutral

= B2

= E2

Flow patternSymmetrical

3 =Ports**

3/4-16 UNF 2-B (SAE8)

Hydraulic control pressure 10–21 bar (145–305 PSI)

2 =4 =6 =

Nominal flow (Δp=10bar [145 PSI])0–10 l/min (0–2.6 GPM)0–20 l/min (0–5.3 GPM)0–30 l/min (0–7.9 GPM)

A

P

T

B

A

PLST

B

= 0

= 4

= B2

A B

Pa b

T

= E2

A B

Pa b

T

Page 152: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-07/10.11 ED-IP Hydraulics | Bosch Rexroth Corp. 3/6

143

Principles of operation, cross section

The sandwich plate design directional valve elements L8_P5… are compact direct hydraulic operated valves which control the start, the stop and the direction of the oil fl ow. These elements basical-ly consist of a stackable housing (1) with a control spool (2), two hydraulic operating blocks (5), and two return springs (4).

The hydraulic pressure in one of the blocks (5) pushes the control spool (2) from its neutral-central position “0” to the required end position “a” or “b”, and the required fl ow from P to A (with B to T), or P to B (with A to T) is achieved. When pressure is removed from either one of blocks (5), the return spring (4) pushes the spool thrust washer (3) back against the housing and the spool returns in its neutral-central position “0”.

1 24 43 35 5

Technical Data (for applications with different specifications consult us)

General

Valve element with 2 hydraulic controls kg (lbs) 1.23 (2.71)

Ambient Temperature °C (°F) –20....+50 (–4....+122) [NBR seals]

Hydraulic

Maximum pressure at P, A, and B ports bar (PSI) 310 (4500)

Maximum pressure at T bar (PSI) 100 [1450]

Maximum pressure at T with joystick bar (PSI) 10 [145]

Maximum pilot pressure bar (PSI) 210 (3045)

Minimum pilot pressure bar (PSI) refer to page 5

Maximum inlet fl ow l/min (GPM) 45 (11.9)

Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR seals]

Permissible degree of fl uid contamination ISO 4572: βx≥75 X=12...15ISO 4406: class 20/18/15NAS 1638: class 9

Viscosity range mm2/s 5....420

Page 153: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED-IP RA 18301-07/10.11

144

4/6

Characteristic curves

Measured with hydraulic fl uid ISO-VG32 at 45° ± 5° C [113° ± 9° F]; ambient temperature 20° C [68° F].

Ordering code S2: 10 l/min (2.64 GPM)

Ordering code S4: 20 l/min (5.28 GPM)

Ordering code S6: 30 l/min (7.92 GPM)

∆P = 20 bar (290 PSI)∆P = 10 bar (145 PSI)

∆P = 20 bar (290 PSI)∆P = 10 bar (145 PSI)

∆P = 20 bar (290 PSI)

∆P = 10 bar (145 PSI)

The performance curves are measured with flow going across and coming back, like P > A and B > T, with symmetrical flow areas and with back-pressure in T ≤ 10 bar (145 PSI)

The curves refer to the spool fully open

A B

P T

A B

P T

307.9

7

6

5

4

3

2

1

0

25

20

15

10

5

00 8 11.5

Pressure ∆p – bar (PSI)

15 18.5 22

0 116 166 217.5 268 319

Flow

Q –

l/m

in (G

PM

)

6015.8

15

12

10

8

6

4

2

0

50

40

30

20

10

0

Flow

Q –

l/m

in (G

PM

)

6015.8

15

12

10

8

6

4

2

0

50

40

30

20

10

0

Flow

Q –

l/m

in (G

PM

)

0 8 11.5

Pressure ∆p – bar (PSI)

15 18.5 22

0 116 166 217.5 268 319

0 8 11.5

Pressure ∆p – bar (PSI)

15 18.5 22

0 116 166 217.5 268 319

Page 154: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-07/10.11 ED-IP Hydraulics | Bosch Rexroth Corp. 5/6

145

External Dimensions and Fittings

1)

7)

10) 9)

2)

5) 3)6) 6)

6)

8)

8)

8)

8)

4) 6)

1 Hydraulic operating element available with inlet port: G1/4 DIN 3852; 9/16-18 UNF 2-B (SAE 6).

2 Flange specifi cations for coupling to ED intermediate elements with ports G 3/8 and SAE 6

3 Flange specifi cations for coupling to ED intermediate elements with LS channels and with ports G 3/8 and SAE 6

4 Flange specifi cations for coupling to ED intermediate elements with ports G 1/2 and SAE 8

5 Flange specifi cations for coupling to ED intermediate elements with LS channels with and ports G 3/8 and SAE 6

6 Three through holes for coupling of the ED Directional Valve Elements. Recommended tie rods M8 with strength class DIN 8.8. Torque 20–22 Nm (14.7–16.2 ft-lb).

7 Four threaded holes M6 for fi tting a secondary fl angeable element (only for elements with ports SAE 8). Bolts M6 with recommended strength class DIN 8.8: torque 9–12 Nm (6.5–9 ft-lb).

8 A and B ports

9 O-Rings for P and T ports

10 Identifi cation label

Page 155: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED-IP RA 18301-07/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

146

6/6

Page 156: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

4/3 4/2 Directional valve elements with manual lever operated control and with or without LS connections

L8_L1… (ED-LV)

147

1/8

Summary

Description Page

General specifi cations 1

Ordering details 2

Confi guration 2

Spool variants 3

Principles of operation, cross section 4

Technical Data 5

Δp-Qv characteristic curves 6

Performance limits 6

External Dimensions and Fittings 7

General specifications

− Valve elements 4 ways 3 positions.

− Control spools manual operated by hand lever.

− Control spool with return spring or mechanical detent for all three positions.

RA 18301-10/03.13Replaces: 10.11

Page 157: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED-LV RA 18301-08/03.13

148

2/8

Ordering Details

Configurations

L 8 _ L 1 _ _ _ _ _ _ _ _ _ 0

Family Directional valve elements ED

ModelSize 6

ConfigurationStandard With channels for Load Sensing

= 0= 4

Operation type Manual lever

Spool variants (refer to page 3)

4/3 4 ways and 3 positions = _ 2

Flow patternSymmetrical = S

0 =2 =3 =

Ports*G 3/8 DIN 3852G 1/2 DIN 3852

3/4-16 UNF 2-B (SAE8)

M1 =F1 =

Manual lever controlWith return spring

With mechanical detent for all three positions

A0 =

A2 =

B0 =

B2 =

Side with the control levera side with handle aiming high

(A and B direction)a side with handle aiming low

(opposite to A and B) b side with handle aiming high

(A and B direction) b side with handle aiming low

(opposite to A and B)

4* =8 =

Nominal flow 1)

18 l/min (5.75 GPM)40 l/min (10.6 GPM)

1) With Δp (P>T) 10 bar (145 psi), corresponding approximately to Δp P>A,B 5 bar (73 psi).* Available only for B_, E_ spool variants.

A

PT

B A

PLST

B

= 0 = 4

Page 158: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-08/03.13 ED-LV Hydraulics | Bosch Rexroth Corp. 3/8

149

Side with the control lever

= _2S_A_M1_a

A B

P T

A B

P T

A B

P T

A B

P T

0 b

= _2S_A_F1_a 0 b

= _2S_B_M1_a 0 b

= _2S_B_F1_a 0 b

Spool variant

= A2S

= B2S

= E2S

= E2S8

a 0 b

Page 159: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED-LV RA 18301-08/10.11

150

4/8

543 1 2

Principles of operation, cross section

The sandwich plate design directional valve elements L8_1… are compact manual operated valves which control the start, the stop and the direction of the oil fl ow.

These elements basically consist of a stackable housing (1) with a control spool (2), a block with the control lever (3), and a spring housing (4) with a return spring (5).

The hand operated lever moves the control spool (2) from its neutral-central position “0” to the required position “a” or “b”, and the required fl ow from P to A (with B to T), or P to B (with A to T) is achieved.

Type L8_L1_2S_ __M100 is the valve version in which the return spring (5) brings the spool back to neutral-central position “0” when the manual lever is not operated.

The valve is available with a choice of spool variants (refer to page 3).

Type L8_L1_2S_ __F100 is the valve version with mechanical detent in which the control spool (2) stays in anyone of the 3 achieved positions “0”, “a” or “b” when the lever is left free. With this valve, the oil delivery can continue without any action on the lever.

Also this version is available with a choice of spool variants (refer to page 3).

Special types of control are available upon request.

Page 160: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-08/03.13 ED-LV Hydraulics | Bosch Rexroth Corp. 5/8

151

Technical Data (for applications with different specifications consult us)

General

Valve element weight kg (lbs) 1.55 (3.42)

Mounting position Unrestricted

Ambient Temperature °C (°F) –20....+50 (–4....+120) [NBR seals]

Hydraulic

Maximum pressure at P, A, and B ports bar (PSI) 310 (4500)

Maximum pressure at T bar (PSI) 160 [2320]

Maximum inlet fl ow l/min (GPM) 60 (15.9)

Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR seals]

Permissible degree of fl uid contamination ISO 4572: βx≥75 X=12...15ISO 4406: class 20/18/15NAS 1638: class 9

Viscosity range mm2/s 5....420

Page 161: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED-LV RA 18301-08/03.136/8

152

Characteristic curves

Measured with hydraulic fl uid ISO-VG32 at 45° ± 5° C (113° ± 9° F); ambient temperature 20° C (68° F).

Performances limits

Minimum flow for efficiency of LS control

Spool VariantCurve No.

P > A P > B A > T B > T P > T

B2S8, E2S8 2 2 4 4 —

A2S8 3 3 3 3 1

B2S4, E2S4 1 1 5 5 —

Spool Variant Curve No.

A2S8, B2S8, E2S8, B2S4, E2S4 1

0

0

10 20 30 40 50 60

2 86 1412104 15.8

l/min

GPMFlow – Q

260250

200

150

100

50

0

PSI18

68

10121416

420

Pre

ssur

e –

Δp

bar1

2

3

4

5

51005000

4000

3000

2000

100

0

PSI350

150

200

250

300

100

50

0

Pre

ssur

e –

p

bar

0

0

10 20 30 40 50 60

2 86 1412104 15.8

l/min

GPMFlow – Q

1

900

750

600

450

300

150

0

PSI60

30

40

50

20

10

0

Pre

ssur

e –

p

bar

0

0

1 2 3 4 5 6

0.3 0.90.6 1.2 1.6

l/min

GPMFlow – Q

Page 162: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18301-08/03.13 ED-LV Hydraulics | Bosch Rexroth Corp.

153

7/8

External Dimensions and Fittings

4 Flange specifi cations for coupling to ED intermediate elements with ports G 3/8

5 For tie rod and tightening torque information see data sheet RE 18301-90.

6 Flange specifi cations for coupling to ED intermediate elements with ports G 1/2 (SAE 8).

7 A and B ports8 Side with the control lever (Standard is side A).9 Hand lever orientation.

10 Hand lever orientation for packing and shipment.11 Identifi cation label.12 LS channel (only for versions L84…).13 Four threaded holes for fi tting secondary fl angeable elements:

– M5 holes on versions with ports G 3/8.– M6 holes on versions with ports SAE 8.– Without when the ports is G 1/2.

Page 163: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics ED-LV RA 18301-08/03.13

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

8/8

154

Page 164: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

155

RA 18301-10/01.13Replaces: 10.11

4/2 and 4/3 on-off directional valve elements with flow sharing control (LUDV concept)

PATENT PENDING

L8510… (EDC-Z)

1/12

General Specifications

− Valve element with direct on-off fl ow sharing control.

− It can achieve multiple simultaneous maneuver by distributing the available fl ow to each actuator selected by the operator, indepen-dently from the working pressure required.

− All simultaneous movements go on at the same reduced speed in case of fl ow shortage.

− Each energized actuator receives a pressure compensated fl ow.

− No shuttle valve fi tted.

− Control spools directly operated by screwed-in solenoids with removable coils.

− Wet pin tubes for DC coils, with push rod for mechanical over-ride; nickel plated surface.

− Manual override (push-button, screw type or lever) available upon request.

− Different plug-in connectors available: see ordering details.

Summary

Description Page

General specifi cations 1

Ordering details 2

Port options 3

Spool variant and Flow pattern 3

Principles of operation, cross section 4

Technical Data 5

∆p-Qv characteristic curves 7

Performance limits 8

External Dimensions and Fittings 9

Electric connection 11

Page 165: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

156

Bosch Rexroth Corp. | Hydraulics EDC-Z RA 18301-10/01.132/12

L 8 5 10 0

Ordering Details

FamilyDirectional valve elements ED

ModelSize 6, on-off

ConfigurationsFlow sharing

Coil typeC36

Spool variants 1)

4/3 operated both sides a and b; P, A, B, T closed in neutral4/2 operated on side a only; P, A, B, T closed in neutral4/2 operated on side b only; P, A, B, T closed in neutral 4/3 operated on both sides a and b; P closed; A and B to T in neutral4/3 operated on side a only; P closed; A and B to T in neutral4/3 operated on side b only; P closed; A and B to T in neutral

= B2

= B3

= B4

= E2

= E3

= E4

Flow pattern & Nominal flow 1), 4) Both meter in and out, A 3 l/min (0.79 gpm) – B 3 l/min (0.79 gpm)Both meter in and out, A 6 l/min (1.59 gpm) – B 6 l/min (1.59 gpm)Both meter in and out, A 9 l/min (2.37 gpm) – B 9 l/min (2.37 gpm)Both meter in and out, A 13 l/min (3.43 gpm) – B 13 l/min (3.43 gpm)Both meter in and out, A 23.5 l/min (6.21 gpm) – B 23.5 l/min (6.21 gpm)Only meter in, A 6 l/min (1.59 gpm) – B 6 l/min (1.59 gpm) 2)

Only meter in, A 9 l/min (2.37 gpm) – B 9 l/min (2.37 gpm) 2)

Only meter in, A 23.5 l/min (6.21 gpm) – B 23.5 l/min (6.21 gpm) 2)

Both meter in and out, A 3 l/min (0.79 gpm) – B 6 l/min (1.59 gpm) 2)

Both meter in and out, A 6 l/min (1.59 gpm) – B 9 l/min (2.37 gpm) 2)

Both meter in and out, A 6 l/min (1.59 gpm) – B 13 l/min (3.43 gpm) 2)

Both meter in and out, A 9 l/min (2.37 gpm) – B 13 l/min (3.23 gpm) 2)

Both meter in and out, A 9 l/min (2.37 gpm) – B 23.5 l/min (6.21 gpm) 2)

Both meter in and out, A 13 l/min (3.43 gpm) – B 23.5 l/min (6.21 gpm) 2)

= S0

= S1

= S2

= S3

= S4

= I1

= I2

= I4

= 01

= 12

= 13

= 23

= 24

= 34

00 =0F =0P =_ _ =

Optional fittingsStandard

Screw type manual overridePush-button type manual override

Lever type manual override 3)

0 =3 =M 5) =

PortsG 3/8 DIN 3852

3/4-16 UNF 2B (SAE8)Machined for interfacing to modular elements

00 =01** =

03 =

04 =

07 =

31 =

Electric connectionsWithout coils

With coils, without mating connector DIN EN 175301-803

With coils, with bi-directional diode, without mating connector vertical Amp-Junior

With coils, with bi-directional diode, without mating connector horizontal Amp-Junior

With coils, with bi-directional diode, without mating connector DT04-2P

With coils and bipolar sheathed lead 350 mm (13.8 inch) long

Voltage supply00 = Without coilOB = 12V DCAD = 13V DCOC = 24V DCAC = 27V DCOD = 48V DCOE = 110V DCOV = (21.5 DC) 24V ACOW = (98 DC) 110V ACOZ = (207 DC) 230V AC

31 07 04 03 01 00

Available connections

1) The required hydraulic layout and spool variant can be chosen by consulting page 3.

2) Available only for E_ spool variant.

3) Each different option for the type of emergency chosen implies a specifi c ordering code (refer to page 7).

4) With ∆p (P > A or P > B) 14 bar (203 psi).

5) See RE18301-45, RE18301-46, RE18301-47, for fl ange-able elements.

** For connectors ordering code see data sheet RE 18325-90.

Page 166: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

157

RA 18301-10/01.13 EDC-Z Hydraulics | Bosch Rexroth Corp. 3/12

Ports Options

a

A B

P T b a

A B

P T b

= 0= 3

= M

Spool Variant and Flow Pattern

a

A B

P T b

a

A B

P T

A B

P T b

a

A B

P T b

a

A B

P T

A B

P T b

a

A B

P T b

a

A B

P T

A B

P T b

= B2

Both meter in and out Only meter in

= B3

= B4

= E2

= E3

= E4

= E2I

= E3I

= E4I

Page 167: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

158

Bosch Rexroth Corp. | Hydraulics EDC-Z RA 18301-10/01.134/12

Principles of Operation, Cross Section

The sandwich plate design directional valve elements L8510… are compact direct operated pressure compensated solenoid valves which control the start, the stop, the direction and the quantity of the oil fl ow, with a FLOW SHARING principle. These elements basically consist of a stackable housing (1) with a control spool, two solenoids (4), two return springs. When energized, each sole-noid (4) displaces the control spool from its neutral-central position “0” and the metering notches are open; fl ow is delivered to the 3 way pressure compensator followed by a check valve for each port A and B. The compensator, balanced by the LS pressure at the opposite end, lifts up and unloads a pressure compensated fl ow which is sent to the A (or B) port through the relevant check valve; at the same time the opposite port allows oil return to tank.

LS pressure reaches the compensator “dead end” directly from the A or B port, while the check valves lock eventual pressure oscilla-tions which could affect the compensator function.

When the solenoid is de-energized, the return spring pushes the spool thrust washer back against the housing and the spool returns in its neutral-central position.

Each coil (4) is fastened to the solenoid tube by a ring nut (7). A pin allows to push the spool under emergency conditions, when the solenoid cannot be energized, like in case of voltage shortage.

5

7 4 2 1 3 4 7

6A B

Page 168: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

159

RA 18301-10/01.13 EDC-Z Hydraulics | Bosch Rexroth Corp. 5/12

Technical Data (for applications with different specifications consult us)

General

Valve element with 2 solenoids kg [lbs] 3.42 [7.54]

Valve element with 1 solenoid kg [lbs] 2.81 [6.19]

Ambient Temperature °C [°F] –20....+50 [–4....+122] (NBR seals)

Hydraulic

Maximum pressure at P, A and B ports bar [psi] 310 [4500]

Maximum pressure at T bar [psi] 210 [3045]

Maximum pressure, with lever type emergency at T bar [psi] 140 [2030]

Maximum fl ow at 14 bar [203 psi] l/min [gpm] 23.5 [6.2]

Maximum fl ow at 18 bar [261 psi] l/min [gpm] 26.5 [7]

Hydraulic fl uid

General properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C [°F] –20....+80 [–4....+176] (NBR seals)

Permissible degree of fl uid contaminationISO 4572: βx≥75 X=12...15ISO 4406: class 20/18/15NAS 1638: class 9

Viscosity range mm2/s 5....420

Electrical

Voltage type DC (AC only with RAC connection)

Voltage tolerance (nominal voltage) % –10 .... +10

Duty Continuous, with ambient temperature ≤ 50°C [122°F]

Coil wire temperature not to be exceeded °C [°F] 150 [302]

Insulation class H

Compliance with Low Voltage Directive LVD 73/23/EC (2006/95/EC), 2004/108/EC

Coil weight with connection EN 175301-803 kg [lbs] 0.215 [0.44]

Voltage V 12 13 24 27 48 11024

+RAC(21.5)

110+RAC(98)

230+RAC(207)

Voltage type DC DC DC DC DC DC AC AC AC

Power consumption 26 26 26 26 26 26 29 29 29

Current (nominal at 20° C [68° F]) A 2.15 2.00 1.10 1.10 0.54 0.27 1.20 0.29 0.14

Resistance (nominal at 20° C [68° F]) Ω 5.5 6.5 22 28 89 413 18 338 1430

Page 169: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

160

Bosch Rexroth Corp. | Hydraulics EDC-Z RA 18301-10/01.136/12

Voltage (V) Connector type Coil description Marking Coil Mat no.

=OB 01 12 DC EN 175301-803 (Ex. DIN 43650) C3601 12DC 12 DC R933000044

=OB 03 12 DC AMP JUNIOR C3603 12DC 12 DC R933000047

=OB 04 12 DC AMP JUNIOR Horizontal C3604 12DC 12 DC R933002913

=OB 07 12 DC DEUTSCH DT 04-2P C3607 12DC 12 DC R933000048

=OB 31 12 DC Cable 350 mm long C3631 12DC 12 DC R933000045

=AD 01 13 DC EN 175301-803 (Ex. DIN 43650) C3601 13DC 13 DC R933000051

=AD 07 13 DC DEUTSCH DT 04-2P C3607 13DC 13 DC R933000049

=OC 01 24 DC EN 175301-803 (Ex. DIN 43650) C3601 24DC 24 DC R93x3000053

=OC 03 24 DC AMP JUNIOR C3603 24DC 24 DC R933000057

=OC 04 24 DC AMP JUNIOR Horizontal C3604 24DC 24 DC R933002914

=OC 07 24 DC DEUTSCH DT 04-2P C3607 24DC 24 DC R933000058

=OC 31 24 DC Cable 350 mm long C3637 24DC 24 DC R933000055

=AC 01 27 DC EN 175301-803 (Ex. DIN 43650) C3601 27DC 27 DC R933000056

=AC 07 27 DC DEUTSCH DT 04-2P C3607 27DC 27 DC R933000050

=OD 01 48 DC EN 175301-803 (Ex. DIN 43650) C3601 48DC 48 DC R933000059

=OD 04 48 DC AMP JUNIOR Horizontal C3604 48DC 48 DC R933002915

=OE 01 110 DC EN 175301-803 (Ex. DIN 43650) C3601 110DC 110 DC R933000061

=OV 01 24 RAC EN 175301-803 (Ex. DIN 43650) C3601 21.5DC 21.5 DC R933000054

=OW 01 110 RAC EN 175301-803 (Ex. DIN 43650) C3601 98DC 98 DC R933000060

=OZ 01 230 RAC EN 175301-803 (Ex. DIN 43650) C3601 207DC 207 DC R933000062

Page 170: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

161

RA 18301-10/01.13 EDC-Z Hydraulics | Bosch Rexroth Corp. 7/12

bar3.0

2.5

2.0

1.5

1.0

0.5

0

psi43.5

40353025201510

50

Ppr

essu

re-∆

p

5 section

4 section

3 section

2 section

1 section

0 10 20 30 40 50 60 l/min

0 2 4 6 8 10 12 14 15.8 gpmFlow-Q

Pressure drop ∆p = ∆p(Q) (PIN – POUT) to the next section

bar30

25

20

15

10

05

0

psi435400350300250200150100

500

Ppr

essu

re-∆

p

0 5 10 15 20 25 30 l/min

0 1 2 3 4 5 6 7 7.9 gpmFlow-Q

P>A or P>B

B>T or A>T

Pressure drop ∆p = ∆p(Q) with spool B2S4

15.85 60gpm l/min

1.051.0

0.8

0.6

0.4

0.2

0

4

3

2

1

0

gpm l/min

50

40

30

Flow

-Q

Flow

-Q

20

10

00

0

bar

Nominal flow = 4

Nominal flow = 3Nominal flow = 2Nominal flow = 1Nominal flow = 0

psi200 400 600 800 870.2

10 20 30

Pressure-∆pPressure differential across the spool (∆P Is)

40 50 0

0

bar

psi1000 2000 3000 3625

50 100 150

Pressure-p

200 250

12

8

4

0

Nominal flow Qnom=Qnom (∆P Is) LS drain

Characteristic Curves

Measured with hydraulic fl uid ISO-VG32 at 45° ± 5°C (113° ± 9°F); ambient temperature 20°C (68°F).

Page 171: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

162

Bosch Rexroth Corp. | Hydraulics EDC-Z RA 18301-10/01.138/12

Performances limits

bar

350

300

250

200

150

100

50

0

psi

5000

4000

3000

2000

1000

0

Pre

ssur

e-p

0 5 10 15 20 25 30 l/min

0 1 2 3 4 5 6 7 7.9 gpmFlow-Q

1 2 3 4 5 SPOOL VARIANT Curve No.

B2S0, E2S0, B3S0, E3S0, B4S0, E4S0,B2I0, E2I0, B3I0, E3I0, B4I0, E4I0 1

B2S1, E2S1, B3S1, E3S1, B4S1, E4S1,B2I1, E2I1, B3I1, E3I1, B4I1, E4I1 2

B2S2, E2S2, B3S2, E3S2, B4S2, E4S2,B2I2, E2I2, B3I2, E3I2, B4I2, E4I2 3

B2S3, E2S3, B3S3, E3S3, B4S3, E4S3,B2I3, E2I3, B3I3, E3I3, B4I3, E4I3 4

B2S4, E2S4, B3S4, E3S4, B4S4, E4S4,B2I4, E2I4, B3I4, E3I4, B4I4, E4I4 5

The performance curves are measured with fl ow going across and coming back, like P>A and B>T. With “lever type” emergency control, the performance limits are slightly lower.

Page 172: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

163

RA 18301-10/01.13 EDC-Z Hydraulics | Bosch Rexroth Corp. 9/12

External Dimensions and Ports

1 Solenoid tube hex 24 mm [0.94 inch].2 Plug for 2 positions versions (4/2); hex 24 mm.3 Ring nut for coil locking (Ø20.4 mm).

Torque 5–6Nm [3.6–4.4 ft-lb].4 Flange specifi cations for coupling to ED intermediate

elements.5 For tie rod and tightening torque information see data sheet

RE 18301-90.6 Clearance needed for connector removal.7 A and B ports.

8 Identifi cation label.9 Optional push-button manual override, 0P type, for spool

opening: it is pressure stuck to the ring nut for coil locking. Mat no. R933000042.

10 Optional screw type manual override, 0F type, for spool open-ing: it is screwed (torque 6–7 Nm [4.4–5.2 ft-lb]) to the tube as replacement of the coil ring nut. Mat no. R933000021.

11 Four threaded holes M5 deepth 12 mm [0.47 inch] for fi tting a secondary fl angeable element. Bolts M5 with recommended strength class DIN8.8: torque 5–6 Nm [3.6–4.4 ft-lb] (only for version with modular secondary valves).

Page 173: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

164

Bosch Rexroth Corp. | Hydraulics EDC-Z RA 18301-10/01.1310/12

External Dimensions and Ports

1 Ordering Details: HA (if fi tted to side A) or HB (if fi tted to side B)

2 Ordering Details: VA (if fi tted to side A) or VB (if fi tted to side B)

3 Ordering Details: H1 (if fi tted to side A) or H9 (if fi tted to side B)

4 Ordering Details: V1 (if fi tted to side A) or V9 (if fi tted to side B)

5 Ordering Details: XA (if fi tted to side A) or XB (if fi tted to side B)

6 Ordering Details: X1 (if fi tted to side A) or X9 (if fi tted to side B)

Page 174: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

165

RA 18301-10/01.13 EDC-Z Hydraulics | Bosch Rexroth Corp. 11/12

Electric connections

= 00 = 01

Protection class: IP 65 with female connectorproperly fi tted (see drawing).

Protection class: IP 65 with female connectorproperly fi tted (see drawing).

= 03 = 04

Protection class: IP 69 K with female connectorproperly fi tted (see drawing).

= 31 = 07

Page 175: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

166

Bosch Rexroth Corp. | Hydraulics EDC-Z RA 18301-10/01.13

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

12/12

Page 176: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

167

RA 18301-11/01.13

4/2 and 4/3 on-off directional valve elements with flow sharing control (LUDV concept)

L8511… (EDC-DZ)

1/10

General Specifications

− Valve element with direct on-off fl ow sharing control.

− It can achieve multiple simultaneous manoeuvres by distribu-ing the available fl ow to each actuator selected by the operator, independently from the working pressure required.

− All simultaneous movements go on at the same reduced speed in case of fl ow shortage.

− Each energized actuator receives a pressure compensated fl ow.

− No shuttle valve fi tted.

− Control spools directly operated by screwed-in solenoids with extractable coils.

− Wet pin tubes for DC coils, with push rod for mechanical over-ride; nickel plated surface.

− Manual override (push-button, screw type or lever) available upon request.

− Different plug-in connectors available: see ordering details.

Summary

Description Page

General specifi cations 1

Ordering details 2

Ports options 3

Spool variants and fl ow patterns 4

Principles of operation, cross section 5

Technical data 6

∆p-Qv characteristic curves 8

Performance limits 8

External dimensions and ports 9

Electric connection 10

Page 177: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

168

Bosch Rexroth Corp. | Hydraulics EDC-DZ RA 18301-11/01.132/10

L 8 5 11 0

Ordering Details

FamilyDirectional valve elements ED

ModelSize 6, on-off

ConfigurationsFlow sharing

Coil typeC36

Spool variants 1)4/3 operated both sides a and b; P, A, B, T closed in neutral4/2 operated on side a only; P, A, B, T closed in neutral4/2 operated on side b only; P, A, B, T closed in neutral 4/3 operated on both sides a and b; P closed; A, B, T in neutral position4/3 operated on side a only; P closed; A, B, T in neutral position4/3 operated on side b only; P closed; A, B, T in neutral position

= B2

= B3

= B4

= E2

= E3

= E4

Flow pattern & Nominal flow 1), 2) Both meter in and out, A 35 l/min (9.25 GPM) – B 35 l/min (9.25 GPM)Both meter in and out, A 48 l/min (12.7 GPM) – B 48 l/min (12.7 GPM)Only meter in, A 35 l/min (9.25 GPM) – B 35 l/min (9.25 GPM) 5)

Only meter in, A 48 l/min (12.7 GPM) – B 48 l/min (12.7 GPM) 5)

Both meter in and out, A 15 l/min (3.9 GPM) – B 35 l/min (9.25 GPM) 5)

Both meter in and out, A 24 l/min (6.3 GPM) – B 35 l/min (9.25 GPM) 5)

Both meter in and out, A 24 l/min (6.3 GPM) – B 48 l/min (12.7 GPM) 5)

Both meter in and out, A 35 l/min (9.25 GPM) – B 48 l/min (12.7 GPM) 5)

= S8

= S9

= I 8

= I 9

= 38

= 48

= 49

= 89

00 =0F =0P =_ _ =

Optional fittingsStandard

Screw type emergencyPush-button type emergency

Lever type emergency 3)

2 =3 =M 4) =

PortsG 1/2 DIN 3852

3/4-16 UNF 2B (SAE8)Machined for interfacing to modular elements

00 =01** =

03 =

04 =

07 =

Electric connectionsWithout coils

With coils, without mating connector DIN EN 175301-803

With coils, with bi-directional diode, without mating connector vertical Amp-Junior

With coils, with bi-directional diode, without mating connector horizontal Amp-Junior

With coils, with bi-directional diode, without mating connector DT04-2P

Voltage supply00 = Without coilsOB = 12V DCAD = 13V DCOC = 24V DCAC = 27V DCOD = 48V DCOE = 110V DCOV = (21.5 DC) 24V ACOW = (98 DC) 110V ACOZ = (207 DC) 230V AC

07 03 01 00

Available connections

1) The required hydraulic layout and spool variant can be chosen by consulting page 3.

2) With ∆P (P>A or P>B) 14 bar [203 psi].

3) Each different option for the type of emergency chosen implies a specifi c ordering code (refer to page 7).

4) See RE18301-45, RE18301-46, RE18301-47, for fl angeable elements.

5) Available only for E_spool variant.

** For connectors ordering code see data sheet RE 18325-90.

Page 178: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

169

RA 18301-11/01.13 EDC-DZ Hydraulics | Bosch Rexroth Corp. 3/10

Adjusting Options

a

A B

P T b a

A B

P T b

= 2= 3

= M

a

A B

P T b

a

A B

P T

A B

P T b

a

A B

P T b

a

A B

P T

A B

P T b

a

A B

P T b

a

A B

P T

A B

P T b

= B2

Both meter in and out Only meter in

= B3

= B4

= E2

= E3

= E4

= E2I

= E3I

= E4I

Spool Variant and Flow Pattern

Page 179: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

170

Bosch Rexroth Corp. | Hydraulics EDC-DZ RA 18301-11/01.134/10

5

7 4 2 1 3 4 7

6A B

Adjusting Options

The sandwich plate design directional valve elements L8511… are compact direct operated pressure compensated solenoid valves which control the start, the stop, the direction and the quantity of the oil fl ow, with a FLOW SHARING principle. These elements basically consist of a stackable housing (1) with a control spool, two solenoids (4), two return springs. When energized, each sole-noid (4) displaces the control spool from its neutral-central position “0” and the metering notches are open; fl ow is delivered to the 3 way pressure compensator followed by a check valve for each port A and B. The compensator, balanced by the LS pressure at the opposite end, lifts up and unloads a pressure compensated fl ow which is sent to the A (or B) port through the relevant check valve; at the same time the opposite port allows oil return to tank.

LS pressure reaches the compensator “dead end” directly from the A or B port, while the check valves lock eventual pressure oscilla-tions which could affect the compensator function.

When the solenoid is de-energized, the return spring pushes the spool thrust washer back against the housing and the spool returns in its neutral-central position.

Each coil (4) is fastened to the solenoid tube by a ring nut (7). A pin allows to push the spool under emergency conditions, when the solenoid cannot be energized, like in case of voltage shortage.

Page 180: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

171

RA 18301-11/01.13 EDC-DZ Hydraulics | Bosch Rexroth Corp. 5/10

Technical Data (for applications with different specifications consult us)

General

Valve element with 2 solenoids kg [lbs] 3.82 [8.42]

Valve element with 1 solenoid kg [lbs] 3.00 [6.61]

Valve element with 2 solenoids andlever type emergency kg [lbs] 4.10 [9.00]

Valve element with 1 solenoid andlever type emergency kg [lbs] 3.25 [7.16]

Ambient Temperature °C [°F] –20....+50 [–4....+122] (NBR seals)

Hydraulic

Maximum pressure at P, A and B ports bar [psi] 310 [4500]

Maximum pressure at T bar [psi] 210 [3045]

Maximum pressure, with lever type emergency at T bar [psi] 140 [2030]

Maximum fl ow l/min [gpm] 48 [12.7]

Hydraulic fl uid

General properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C [°F] –20....+80 [–4....+176] (NBR seals)

Permissible degree of fl uid contaminationISO 4572: bx≥75 X=12...15ISO 4406: class 20/18/15NAS 1638: class 9

Viscosity range mm2/s 5....420

Electrical

Voltage type DC (AC only with RAC connection)

Voltage tolerance (nominal voltage) % –10 .... +10

Duty Continuous, with ambient temperature ≤ 50°C [122°F]

Maximum coil temperature °C [°F] 150 [302]

Insulation class H

Compliance with Low Voltage Directive LVD 73/23/EC (2006/95/EC), 2004/108/EC

Coil weight with connection EN 175301-803 kg [lbs] 0.335 [0.74]

Voltage V 12 13 24 27 48 11024

+RAC(21.5)

110+RAC(98)

230+RAC(207)

Voltage type DC DC DC DC DC DC AC AC AC

Power consumption W 33 31 33 33 33 35 33 33 35

Current 1) A 2.80 2.30 1.40 1.20 0.70 0.32 1.60 0.34 0.16

Resistance 2) Ω 4.24 5.42 17 21.8 69.8 341.8 13.6 285 1229

1) Nominal 2) ± 7% at temperature 20°C [68°F]

Page 181: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

172

Bosch Rexroth Corp. | Hydraulics EDC-DZ RA 18301-11/01.136/10

Voltage (V) Connector type Coil description Marking Coil Mat no.

=OB 01 12 DC EN 175301-803 C4501 12DC 12 DC R933000026

=OB 03 12 DC AMP-Junior C4503 12DC 12 DC R933000027

=OB 07 12 DC DEUTSCH DT 04-2P C4507 12DC 12 DC R933000030

=AD 01 13 DC EN 175301-803 C4501 13DC 13 DC R933000028

=AD 03 13 DC AMP-Junior C4503 13DC 13 DC R933000029

=AD 07 13 DC DEUTSCH DT 04-2P C4507 13DC 13 DC R933000031

=OC 01 24 DC EN 175301-803 C4501 24DC 24 DC R933000034

=OC 03 24 DC AMP-Junior C4503 24DC 24 DC R933003630

=OC 07 24 DC DEUTSCH DT 04-2P C4507 24DC 24 DC R933000032

=AC 01 27 DC EN 175301-803 C4501 27DC 27 DC R933000035

=AC 03 27 DC AMP-Junior C4503 27DC 27 DC R933000036

=AC 07 27 DC DEUTSCH DT 04-2P C4507 27DC 27 DC R933000033

=OD 01 48 DC EN 175301-803 C4501 48DC 48 DC R933000037

=OE 01 110 DC EN 175301-803 C4501 110DC 110 DC R933000040

=OV 01 24 RAC EN 175301-803 C4501 21.5DC 21.5 DC R933000038

=OW 01 110 RAC EN 175301-803 C4501 98DC 98 DC R933000039

=OZ 01 230 RAC EN 175301-803 C4501 207DC 207 DC R933000041

Page 182: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

173

RA 18301-11/01.13 EDC-DZ Hydraulics | Bosch Rexroth Corp. 7/10

Characteristic curves

Measured with the hydraulic fl uid ISO-VG32 at 45° ±5° C (113° ± 9° F); ambient temperature 20° C (68° F)

Performances limits

Measured with the hydraulic fl uid ISO-VG32 at 45° ±5° C (113° ± 9° F); ambient temperature 20° C (68° F)

SPOOL VARIANT Curve No.

B2S8, E2S8, B3S8, E3S8, B4S8, E4S8, B2I8, E2I8, B3I8, E3I8, B4I8, E4I8

1

B2S9, E2S9, B3S9, E3S9, B4S9, E4S9, B2I9, E2I9, B3I9, E3I9, B4I9, E4I9

2

The performance curves are measured with fl ow going across and coming back, like P>A and B>T. With “lever type” emergency control, the performance limits are slightly lower.

l/min

80

70

60

50

40

30

10

20

0

gpm21.13

l/min3.0

2.5

2.0

1.5

1.0

0.5

0

gpm43.5

40353025201510

50

20

16l/min

4

3

2

1

0

gpm1.05

1.0

0.8

0.6

0.4

0.2

0

12

8

4

0

Flow

– Q

Flow

– Q

0 10 15 20 25 30 bar

Nominal flow = 9

5 section

4 section

3 section

2 section

1 section

Nominal flow = 8

0 200 400 600 800 870.2 psiPressure – ∆p

0 10 20 30 40 50 60 l/min

0 2 4 6 8 10 12 14 15.8 gpmFlow – Q

Pre

ssur

e – ∆p

Pressure differential across the spool (∆P Is)

0 10 15 20 25 30 bar

0 1000 2000 3000 3625 psiPressure – p

Nominal flow Qnom = Qnom (∆P Is)

Version: Pressure drop ∆p = ∆p(Q) (PIN – POUT) to the next section

LS drain

bar

350

1 2

300

250

200

150

100

50

0

psi

5000

4000

3000

2000

1000

0

Pre

ssur

e-p

0 10 20 30 40 50 60 l/min

0 2 4 6 8 10 12 14 15.8 gpmFlow-Q

Page 183: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

174

Bosch Rexroth Corp. | Hydraulics EDC-DZ RA 18301-11/01.138/10

External Dimensions and Ports

1 Solenoid tube Ø19 mm [0.75 inch].2 Plug for 2 positions versions (4/2).3 Ring nut for coil locking (Ø26.5 mm).

Torque 6–7Nm [4.4–5.2 ft-lb].4 Flange specifi cations for coupling to ED intermediate

elements.5 For tie rod and tightening torque information, see data sheet

RE 18301-90.6 Clearance needed for connector removal.7 A and B ports.8 Identifi cation label.

9 Optional push-button manual override, 0P type, for spool opening: it is pressure stuck to the ring nut for coil locking.Mat no. R933000043.

10 Optional screw type emergency, 0F type, for spool opening: it is screwed (torque 6–7 [4.4–5.2 ft-lb]) to the tube as replacement of the coil ring nut. Mat no. R933007215.

11 Four threaded holes M5 depth 12 mm [0.47 inch] for fi tting a secondary fl angeable element. Bolts M5 with recommended strength class DIN8.8: torque 5–6 Nm [3.6–4.4 ft-lb]. (only for version with modular secondary valves).

Page 184: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

175

RA 18301-11/01.13 EDC-DZ Hydraulics | Bosch Rexroth Corp. 9/10

External Dimensions and Ports

1 Ordering Details: HA (if fi tted to side A) or HB (if fi tted to side B)

2 Ordering Details: VA (if fi tted to side A) or VB (if fi tted to side B)

3 Ordering Details: H1 (if fi tted to side A) or H9 (if fi tted to side B)

4 Ordering Details: V1 (if fi tted to side A) or V9 (if fi tted to side B)

5 Ordering Details: XA (if fi tted to side A) or XB (if fi tted to side B)

6 Ordering Details: X1 (if fi tted to side A) or X9 (if fi tted to side B)

Page 185: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

176

Bosch Rexroth Corp. | Hydraulics EDC-DZ RA 18301-11/01.13

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

10/10

Electric connections

= 00 = 01

Protection class: IP 65 with female connectorproperly fi tted (see drawing).

Protection class: IP 69 K with female connector.

= 03 = 07

Page 186: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

177

RA 18301-09/01.13Replaces: 10.11

4/3 and 4/2 Proportional directional valve elements with flow sharing control (LUDV concept)

PATENT PENDING

L8580... (EDC-P)

1/10

General Specifications

− Valve element with direct proportional fl ow sharing control.

− It can achieve the simultaneous activation of different actuators by distributing the available fl ow proportionally to the speeds selected by the operator.

− All simultaneous movements go on at the same reciprocal speed also in case of fl ow shortage.

− Each energized actuator receives a pressure compensated fl ow.

− No shuttle valve fi tted.

− Wet pin proportional tubes for DC coils, with push rod for mechanical override; nickel plated surface.

− Manual override (push-button, screw type or lever) available upon request.

− Different plug-in connectors available: see ordering details.

Summary

Description Page

General specifi cations 1

Ordering details 2

Ports options 3

Spool variant and Flow pattern 4

Principles of operation, cross section 5

Technical Data 6

∆p-Qv characteristic curves 8

External Dimensions and Fittings 9

Electric connection 10

Page 187: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

178

Bosch Rexroth Corp. | Hydraulics EDC-P RA 18301-09/01.132/10

L 8 5 80 0

Ordering Details

00 =0F =0P =_ _ =

Optional fittingsWithout manual override

Screw type manual overridePush-button type manual override

Lever type manual override 3)

0 =2 =3 =M =

PortsG 3/8 DIN 3852G 1/2 DIN 3852

3/4-16 UNF 2B (SAE8)Machined for interfacing to modular elements

00 =01** =

03 =07 =

Electric connections Without coils

With coils, without mating connectorDIN EN 175301-803

With coils , with bi-directional diode, without mating connector vertical Amp-Junior

With coils, with bi-directional diode, without mating connector DT04-2O

00 =OB =OC =

Voltage suppllyWithout coils

12V DC24V DC

1) The required hydraulic layout and spool variant can be chosen by consulting page 3.

2) Available only for E_ spool variant.

3) Each different option for the type of emergency chosen implies a specifi c ordering code (refer to page 8).

4) With ∆p (P > A or P > B) 14 bar (203 psi).

5) See RE18301-45, RE18301-46, RE18301-47, for fl angeable elements.

** For connectors ordering code see data sheet RE 18325-90.

FamilyDirectional valve elements ED

ModelSize 6, proportional

ConfigurationsFlow sharing

Coil typeDiameter 23 mm (0.91 in.)

Spool variants 1)

4/3 operated both sides a and b; P, A, B, T closed in neutral4/2 operated on side a only; P, A, B, T closed in neutral4/2 operated on side b only; P, A, B, T closed in neutral 4/3 operated on both sides a and b; P closed; A and B to T in neutral4/3 operated on side a only; P closed; A and B to T in neutral4/3 operated on side b only; P closed; A and B to T in neutral

= B2

= B3

= B4

= E2

= E3

= E4

Flow pattern & Nominal flow 1), 4)

Both meter in and out, A 4 l/min [1.06 gpm] – B 4 l/min (1.06 gpm)Both meter in and out, A 8 l/min (1.85 gpm) – B 8 l/min (1.85 gpm)Both meter in and out, A 12 l/min (3.17 gpm) – B 12 l/min (3.17 gpm)Both meter in and out, A 16 l/min (4.23 gpm) – B 16 l/min (4.23 gpm)Both meter in and out, A 25 l/min (6.6 gpm) – B 25 l/min (6.6 gpm)Both meter in and out, A 40 l/min (10.57 gpm) – B 40 l/min (10.57 gpm)Both meter in and out, A 50 l/min (13.2 gpm) – B 50 l/min (13.2 gpm)Only meter in, A 8 l/min (1.85 gpm) – B 8 l/min (1.85 gpm) 2)

Only meter in, A 12 l/min (3.17 gpm) – B 12 l/min (3.17 gpm) 2)

Only meter in, A 25 l/min (6.6 gpm) – B 25 l/min (6.6 gpm) 2)

Only meter in, A 40 l/min (10.57 gpm) – B 40 l/min (10.57 gpm) 2)

Only meter in, A 50 l/min (13.2 gpm) – B 50 l/min (13.2 gpm) 2)

Both meter in and out, A 4 l/min (1.06 gpm) – B 8 l/min (1.85 gpm) 2)

Both meter in and out, A 8 l/min (1.85 gpm) – B 12 l/min (3.17 gpm) 2)

Both meter in and out, A 8 l/min (1.85 gpm) – B 16 l/min (4.23 gpm) 2)

Both meter in and out, A 12 l/min (3.17 gpm) – B 16 l/min (4.23 gpm) 2)

Both meter in and out, A 12 l/min (3.17 gpm) – B 25 l/min (6.6 gpm) 2)

Both meter in and out, A 16 l/min (4.23 gpm) – B 25 l/min (6.6 gpm) 2)

Both meter in and out, A 16 l/min (4.23 gpm) – B 40 l/min (10.57 gpm) 2)

Both meter in and out, A 25 l/min (6.6 gpm) – B 40 l/min (10.57 gpm) 2)

Both meter in and out, A 25 l/min (6.6 gpm) – B 50 l/min (13.2 gpm) 2)

Both meter in and out, A 40 l/min (10.57 gpm) – B 50 l/min (13.2 gpm) 2)

= S0= S1= S2

= S3

= S4

= S8

= S9

= I1= I2= I4= I8= I9= 01

= 12

= 13

= 23

= 24

= 34

= 38

= 48

= 49

= 89

Page 188: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

179

RA 18301-09/01.13 EDC-P Hydraulics | Bosch Rexroth Corp. 3/10

Ports Options

a

A B

P T b a

A B

P T b

= 0= 2= 3

= M

Spool Variant and Flow Pattern

a

A B

P T b

a

A B

P T

A B

P T b

a

A B

P T b

a

A B

P T

A B

P T b

a

A B

P T b

a

A B

P T

A B

P T b

= B2

Both meter in and out Only meter in

= B3

= B4

= E2

= E3

= E4

= E2I

= E3I

= E4I

Page 189: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

180

Bosch Rexroth Corp. | Hydraulics EDC-P RA 18301-09/01.134/10

Principles of Operation, Cross Section

The sandwich plate design directional valve elements L8580… are compact direct operated pressure compensated proportional solenoid valves which control the start, the stop, the direction and the quantity of the oil fl ow, with a FLOW SHARING principle. These elements basically consist of a stackable housing (1) with a control spool, two solenoids (4), two return springs. Energized by an electronic feed regulator, each solenoid (4) displaces the control spool from its neutral-central position “0” proportionally to the current received. When the spool is shifted and the metering notch is open, fl ow delivery starts and is controlled by a 3 way pressure compensator followed by a check valve for each port A and B. The compensator, balanced by the LS pressure at the opposite end, lifts up and unloads a regulated fl ow which is sent to the A (or B) port through the relevant check valve; at the same time the oppo-site port allows oil return to tank.

LS pressure reaches the compensator “dead end” directly from the A or B port, while the check valves lock eventual pressure oscilla-tions which could affect the compensator function.

When the solenoid is de-energized, the return spring pushes the spool thrust washer back against the housing and the spool returns in its neutral-central position.

Each coil (4) is fastened to the solenoid tube by the ring nut (7). A pin allows to push the spool under emergency conditions, when the solenoid cannot be energized, like in case of voltage shortage.

5

7 4 2 1 3 4 7

6A B

Page 190: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

181

RA 18301-09/01.13 EDC-P Hydraulics | Bosch Rexroth Corp. 5/10

Technical Data (for applications with different specifications consult us)

General

Valve element with 2 solenoids kg [lbs] 3.95 [8.71]

Valve element with 1 solenoid kg [lbs] 3.6 [7.91]

Ambient Temperature °C [°F] –20....+50 [–4....+122] (NBR seals)

Hydraulic

Maximum pressure at P, A and B ports bar [psi] 310 [4500]

Maximum pressure at T bar [psi] 210 [3045]

Maximum pressure with lever emergency at T bar [psi] 140 [2030]

Maximum regulated fl ow at 14 bar [203 psi] l/min [gpm] 50 [13.2]

Maximum regulated fl ow at 18 bar [261 psi] l/min [gpm] 58 [15.3]

E-schemes fl ow pattern symmetrical closed pass in the neutral position (connection from A to T and B to T) Approx. 2% of the nominal cross-section

Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C [°F] –20....+80 [–4....+176] (NBR seals)

Permissible degree of fl uid contaminationISO 4572: βx≥75 X=10...12ISO 4406: class 19/17/14NAS 1638: class 8

Viscosity range mm2/s 20....380 (optional 30....46)

Electrical

Voltage type PWM Pulse Width Modulation pre-set at 120 Hz

Voltage tolerance (nominal voltage) % –10 .... +10

Duty Continuous, with ambient temperature ≤ 50°C [122°F]

Maximum coil temperature °C [°F] 150 [302]

Insulation class H

Compliance with Low Voltage Directive LVD 73/23/EC (2006/95/EC), 2004/108/EC

Coil weight kg [lbs] 0.335 [0.739]

Voltage V 12 24

Current (nominal at 20° C[68° F]) A 1.76 0.88

Resistance(nominal at 20° C[68° F])

– Cold value at 20°C Ω 4 16

– Max. hot value Ω 6.1 24.4

Voltage (V) Connector type Coil description Marking Coil mat. no.

=OB 01 12 DC EN 175301-803 (Ex. DIN 43650) D15 01 12 DC R933000092

=OB 03 12 DC AMP JUNIOR D15 03 12 DC R933002877

=OB 07 12 DC DEUTSCH DT 04-2P D15 07 12 DC R933000094

=OC 01 24 DC EN 175301-803 (Ex. DIN 43650) D15 01 24 DC R933000093

=OC 03 24 DC AMP JUNIOR D15 03 24 DC R933003515

=OC 07 24 DC DEUTSCH DT 04-2P D15 07 24 DC R933002798

Page 191: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

182

Bosch Rexroth Corp. | Hydraulics EDC-P RA 18301-09/01.136/10

Characteristic Curves

Measured with hydraulic fl uid ISO-VG32 at 45° ± 5°C (113° ± 9°F); ambient temperature 20°C (68°F).

0 20 40 60 80 100

l/min6

5

4

3

2

1

0

gpm1.61.5

1.2

0.9

0.6

0.3

0

∆p = 261 psi∆p = 18 bar∆p = 203 psi∆p = 14 bar

Nominal Flow = 0

3/1 - Characteristic curves Q=Q (I)

Flow

-Q

% of maximum control current %A

0 20 40 60 80 100% of maximum control current

%A

l/min18

15

12

9

6

3

0

gpm4.7

4

3

2

1

0

∆p = 261 psi∆p = 18 bar∆p = 203 psi∆p = 14 bar

0 20 40 60 80 100% of maximum control current

%A

0 20 40 60 80 100% of maximum control current

%A

∆p = 261 psi∆p = 18 bar

∆p = 203 psi∆p = 14 bar

∆p = 261 psi∆p = 18 bar∆p = 203 psi∆p = 14 bar

Nominal Flow = 2

Flow

-Q

l/min30

25

20

15

10

5

0

gpm7.9

76543210

Nominal Flow = 4

0 20 40 60 80 100

∆p = 261 psi∆p = 18 bar∆p = 203 psi∆p = 14 bar

Nominal Flow = 1

% of maximum control current %A

0 20 40 60 80 100% of maximum control current

%A

∆p = 261 psi∆p = 18 bar∆p = 203 psi∆p = 14 bar

0 20 40 60 80 100% of maximum control current

%A

∆p = 261 psi∆p = 18 bar∆p = 203 psi∆p = 14 bar

Nominal Flow = 3

Nominal Flow = 8

Flow

-Q

l/min

60

50

40

30

20

10

0

gpm16.37

12

8

4

0

Nominal Flow = 9

Flow

-Q

l/min60

50

40

30

20

10

0

gpm15.8

141210

86420

Flow

-Q

l/min12

10

8

6

4

2

0

gpm3.2

2.5

2.0

1.5

1.0

0.5

0

Flow

-Q

l/min

24

20

16

12

8

4

0

gpm

6.36

5

4

3

2

1

0

Flow

-Q

The curves refer to the spool fully open.

Page 192: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

183

RA 18301-09/01.13 EDC-P Hydraulics | Bosch Rexroth Corp. 7/10

Characteristic Curves

Measured with hydraulic fl uid ISO-VG32 at 45° ± 5°C (113° ± 9°F); ambient temperature 20°C (68°F).

bar3.0

2.5

2.0

1.5

1.0

0.5

0

psi43.5

40353025201510

50

Ppr

essu

re-∆

p

5 section

4 section

3 section

2 section

1 section

0 10 20 30 40 50 60 l/min

0 2 4 6 8 10 12 14 15.8 gpmFlow-Q

Pressure drop ∆p = ∆p(Q) (PIN – POUT) to the next section

bar30

25

20

15

10

05

0

psi435400350300250200150100

500

Ppr

essu

re-∆

p

0 10 20 30 40 50 60 l/min

0 2 4 6 8 10 12 14 15.8 gpmFlow-Q

P>A or P>B

B>T or A>T

Pressure drop ∆p = ∆p(Q) with spool B2S9

21.1320

15

10

5

80

70

60

50

40

30

20

10

gpm l/min

1.051.0

0.8

0.6

0.4

0.2

0

4

3

2

1

00 50 100 150 200 250

gpm l/min

Flow

-Q

Flow

-Q

0 10 15 20 25 30

0 300 500 700 870.2

bar

Nominal flow = 9

Nominal flow = 8

Nominal flow = 4

Nominal flow = 1Nominal flow = 2Nominal flow = 3

Nominal flow = 0

psi

bar

psiPressure-∆p

Pressure differential across the spool (∆P Is)

0 1000 2000 3000 3625Pressure-p

0 0

Nominal flow Qnom=Qnom (∆P Is)

LS drain

Page 193: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

184

Bosch Rexroth Corp. | Hydraulics EDC-P RA 18301-09/01.138/10

External Dimensions and Fittings

1 Solenoid tube Ø23 mm (0.91 inch).

2 Plug for 2 positions versions (4/2).

3 Ring nut for coil locking (Ø30.3 mm). Torque 6–7 Nm (4.4–5.2 ft-lb).

4 Flange specifi cations for coupling to ED intermediate elements.

5 For tie rod and tightening torque information see data sheet RE 18301-90.

6 Clearance needed for connector removal.

7 A and B ports.

8 Identifi cation label.

9 Optional push-button manual override, 0P type, for spool opening: it is pressure stuck to the ring nut for coil locking.Mat no. R933003289.

10 Optional screw type manual override, 0F type, for spool opening: it is screwed (torque 6-7 Nm [4.4-5.2 ft-lb]) to the tube as replacement of the coil ring nut. Mat no. R933003116.

11 Four threaded holes M5 deepth 12mm [0.47 inch] for fi tting a secondary fl angeable element. Bolts M5 with recommended strength class DIN8.8: torque 5-6 Nm [3.6-4.4 ft-lb] (only for version with modular secondary valves).

Page 194: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

185

RA 18301-09/01.13 EDC-P Hydraulics | Bosch Rexroth Corp. 9/10

External Dimensions and Ports

1 Ordering Details: HA (if fi tted to side A) or HB (if fi tted to side B)

2 Ordering Details: VA (if fi tted to side A) or VB (if fi tted to side B)

3 Ordering Details: H1 (if fi tted to side A) or H9 (if fi tted to side B)

4 Ordering Details: V1 (if fi tted to side A) or V9 (if fi tted to side B)

5 Ordering Details: XA (if fi tted to side A) or XB (if fi tted to side B)

6 Ordering Details: X1 (if fi tted to side A) or X9 (if fi tted to side B)

Page 195: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

186

Bosch Rexroth Corp. | Hydraulics EDC-P RA 18301-09/01.13

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

10/10

Electric connection (or connections, in case of two solenoids)

Protection class: IP 65 when connector with seal is properly screwed down.

= 01

Protection class: IP 65 with female connectorproperly fi tted (see drawing).

Protection class: IP 69 K with female connectorproperly fi tted (see drawing).

= 03 = 07

Page 196: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

187

Description

The intermediate elements TI-00-__- are designed to be fi tted between two directional valve elements. They are available with check valve in (P) line, or in (T) line , or in both (P) and (T) line.

With the check valve on (P) line, they are normally fi tted to allow free fl ow from (P) to (P1) and prevent reverse fl ow from (P1) to (P).

With the check valve on (T) line, they are normally fi tted to allow free fl ow from (T1) to (T), and to prevent reverse fl ow (T) to (T1).

Technical Data (for applications outside these parameters, please consult us)

General

TI-00-PT.. Weight kg (lbs) 0.54 (1.19)TI-00-0P.. Weight kg (lbs) 0.52 (1.15)TI-00-0T.. Weight kg (lbs) 0.52 (1.15)Ambient Temperature °C (°F) –20....+50 (–4....+120)

HydraulicMaximum pressure bar (PSI) 250 (3625)Maximum inlet fl ow l/min (GPM) 50 (13.2)Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR]

Permissible degree of fl uid contaminationISO 4572: βx≥75 X=12...15ISO 4406: classe 20/18/15NAS 1638: classe 9

Viscosity range mm2/s 5....420

Hydraulic Symbol

P1

T1

P2

T2

M

TI-00-PT

P1

T1

P2

T2

M

TI-00-0P

P1

T1

P2

T2

M

TI-00-0T

10

8

6

4

2

00 10 20

Flow Q

30 40 50

0 3 6 9 12 13.2

l/min

GPM

140barPSI

112

84

56

28

0

Pre

ssur

e ∆p

Pressure drop through thecheck valves P > P1 and T1 > T

RA 18301-25/10.11

Intermediate elements with check valves for emergency pump

TI-00-__-

1/2

Page 197: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

188

Bosch Rexroth Corp. | Hydraulics TI-00 RA 18301-25/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

4)

3)

1) 2)

2/2

Ordering Details

External Dimensions and Fittings

1 Flange specifi cations for coupling to ED interme-diate elements.

2 Three through holes (8.1 mm dia.) for coupling of the ED directional valve elements. Recommended tie rods M8 with strength class DIN 8.8. Torque 20–22 Nm (14.7–16.2 ft-lb).

3 Identifi cation label.

4 Test point for pressure gauge connection.

TI - 0 0 - _ _ - 0 1 - A LFamily Intermediate element

Configuration with checking valves for emergency pump

Check valve positionOn pressure line POn tank line TOn both lines P and T

= 0P= 0T= PT

Material Aluminium

Cracking pressure 1 bar (14.5 PSI)

TI - 00 - . . -

Page 198: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

189

Description

The intermediate elements TI-03-__- are designed to be fi tted between two directional valve elements. They have a pressure reducing and relieving cartridge which supplies a fl ow with constant reduced pressure to the downstream operators.

The same cartridge relieves to Tank directly any excessive pressure surge in the downstream line.

These elements basically consist of a stackable aluminium housing, with a VRPX-10A type pressure reducing cartridge.

Technical Data (for applications outside these parameters, please consult us)

General

Intermediate element without cartridge TI-03-00-00-AL kg (lbs) 0.42 (0.93)

Intermediate element without cartridge TI-03-00-_ _-AL kg (lbs) 0.52 (1.15)

Ambient Temperature °C (°F) –20....+50 (–4....+120)

HydraulicMaximum pressure bar (PSI) 250 (3625)Maximum inlet fl ow l/min (GPM) 50 (13.2)Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR]

Permissible degree of fl uid contaminationISO 4572: βx≥75 X=12...15ISO 4406: classe 20/18/15NAS 1638: classe 9

Viscosity range mm2/s 5....420

Hydraulic Symbol

M

PLS

T

P1LST1

RA 18301-26/10.11

Intermediate elements with pressure reducer, and relieving

TI-03-__-

1/2

Page 199: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

190

Bosch Rexroth Corp. | Hydraulics TI-03 RA 18301-26/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

2)

3)1)

2/2

Ordering Details

External Dimensions and Fittings

TI - 0 3 - 0 0 - _ _ - A L

Family Intermediate element

Configuration with pressure reducer and relieving

MaterialAluminium

V1 =V2 =

Pressure reducing valve range35–140 bar (500–2000 PSI)

70–280 bar (1000–4000 PSI)

TI - 03 - . . -

1 Three through holes (8.5 mm dia.) for coupling of the ED directional valve elements. Recommended tie rods M8 with strength class DIN 8.8. Torque 20–22 Nm (14.7–16.2 ft-lb).

2 Pressure reducing and relieving cartridge VRPX (refer to RE 18301-91).

3 Identifi cation label.

4 Test point for pressure gauge connection.

Page 200: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

191

Description

The intermediate elements TI-04-__- are designed to be fi tted between two directional valve elements. They incorporate an adjustable fl ow restrictor which limits the fl ow at the outlet P1 for the downstream operators.

The body is made of black anodized aluminium (Al).

Technical Data (for applications outside these parameters, please consult us)

General

Weight with cartridge kg (lbs) 0.42 (0.93)Weight without cartridge kg (lbs) 0.52 (1.15)Ambient Temperature °C (°F) –20....+50 (–4....+120)

HydraulicMaximum pressure bar (PSI) 250 (3625)Maximum inlet fl ow l/min (GPM) 50 (13.2)Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR]

Permissible degree of fl uid contaminationISO 4572: βx≥75 X=12...15ISO 4406: classe 20/18/15NAS 1638: classe 9

Viscosity range mm2/s 5....420

Hydraulic Symbol

M

P

T

P1

T1

RA 18301-27/10.11

Intermediate elements with flow regulator on P line

TI-04-__-

1/2

Page 201: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

192

Bosch Rexroth Corp. | Hydraulics TI-04 RA 18301-27/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

2/2

Ordering Details

External Dimensions and Fittings

TI - 04 - . . -

3)

4)

5)

1)

2)

1 Flange specifi cations for coupling to ED intermediate elements.

2 Three through holes (8.1 mm dia.) for coupling of the ED directional valve elements. Recommended tie rods M8 with strength class DIN 8.8. Torque 20–22 Nm (14.7–16.2 ft-lb).

3 Identifi cation label.

4 Test point M(G 1/4) for pressure gauge connection.

5 Flow regulator cartridge ST-C-06.

T I - 0 4 - 0 1 - A L

Material Aluminium

Family Intermediate element

Configuration with flow regulator on P line

Page 202: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

193

Description

The sandwich plate design directional valve elements TI-C2-__-… basically consist of a stackable housing with a 2 way compensator controlled by the LS pressure signal. The normally open compensator maintains a constant pres-sure difference between the P1 (outlet) line and the LS pressure; the result is a constant oil fl ow to the P1 port for the downstream operators, independently from the working pressure.

The excess oil must be unloaded to tank through a relief valve.

The stackable housing is made of Yellow Zinc plated (Cr+3) Cast Iron.

Technical Data (for applications outside these parameters, please consult us)

General

Valve element TI-C2-__- kg (lbs) 1.7 (3.75)Ambient Temperature °C (°F) –20....+50 (–4....+120)

HydraulicMaximum pressure bar (PSI) 310 (4500)Maximum inlet fl ow l/min (GPM) 30 (7.9)Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR]

Permissible degree of fl uid contaminationISO 4572: βx≥75 X=12...15ISO 4406: classe 20/18/15NAS 1638: classe 9

Viscosity range mm2/s 5....420

Hydraulic Symbol

15barPSI

l/minGPM

200

150

100

50

0

12

9

6

3

0

0

2

4

6

8

10

1213.2

0

10

20

30

40

50

0 10

0 2 4 6 8 10 13.2

20

Flow Q

Pressure ∆p

30 40 50

0

0 1000 2000 3625

50 100 150 200 250

PSI

bar

GPM

l/min

Pre

ssur

e ∆p

Flow

Q

RA 18301-28/10.11

Intermediate elements with 2 way compensator, and with LS connections

TI-C2-__-__

1/2

Page 203: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

194

Bosch Rexroth Corp. | Hydraulics TI-C2 RA 18301-28/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

2/2

Ordering Details

External Dimensions and Fittings

1 Flange specifi cations for coupling to ED intermediate elements. 2 Three through holes (8.1 mm dia.) for coupling of the ED directional valve elements. Recommended tie rods M8 with strength class DIN 8.8. Torque 20–22 Nm (14.7–16.2 ft-lb).

T I - C 2 - M 0 - 0 0

Version Standard

Compensator springSetting 6 bar (87 PSI)

Family Intermediate element

Configuration with 2-way compensator and with LS connections

1)2)

Page 204: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

195

Description

The adaptor elements TI-M412 -__ are employed to connect an ED directional valve assembly to a main control valve Rexroth M4-12.

These elements basically consist of body made of Yellow Zinc plated (Cr+3) steel which incorporates the following items:

− a check valve on the P – P1 line.

− a shuttle valve on the LS lines.

− a relief valve on the un the LS line which controls the maximum pressure output from the pump.

− a pressure compensated orifi ce which drains to tank the LS pressure by unloa-ding a small regulated fl ow.

Technical Data (for applications outside these parameters, please consult us)

General

Valve element TI-C2-__- kg (lbs) 6 (13.2)Ambient Temperature °C (°F) –20....+50 (–4....+120)

HydraulicMaximum pressure bar (PSI) 310 (4500)

Maximum fl ow at P1 The max. rated fl ow depends on the directional control element

Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR]

Permissible degree of fl uid contaminationISO 4572: βx≥75 X=12...15ISO 4406: classe 20/18/15NAS 1638: classe 9

Viscosity range mm2/s 5....420

Hydraulic Symbol

LS

LS

ED...

P1

LS

T

LS

T

X

Y

T

RA 18301-29/10.11

Intermediate elements for interfacing ED with M4-12

TI-M412-__-__

1/2

Page 205: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

196

Bosch Rexroth Corp. | Hydraulics TI-M412 RA 18301-29/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

2/2

Ordering Details

External Dimensions and Fittings

5)

3)

4)

1)2)

1 Flange specifi cations for coupling to ED directional valve elements.

2 Three threaded holes M8 for screwing the M8 tie rods of the ED Directional Valve Elements. Recommended strength class DIN 8.8; torque 20–22 Nm (14.7–16.2 ft-lb).

3 No. 2 threaded holes M10 for assembling to the Main Directional Control Valve M4-12.

4 No. 3 holes 10.5 mm dia. for assembling M4-12 directional valve elements.

5 LS port (locked by a G 1/4 plug).

T I - M 4 1 2 0 0 - _ _ - S T

FamilyIntermediate element

ConfigurationAdaptor plate for interfacing EDwith Rexroth M4-12

LS port (external)G 1/4

MaterialZinc plated (Cr+3) steel

01 =02 =03 =

P1 pressure range50–210bar (725–3045 PSI)

100–310bar (1450–4500 PSI)25–50bar (362–725 PSI)

Page 206: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

197

Description

The intermediate plate with an auxiliary hand pump has to be insert between the inlet plate and the ED modular directional valves. It necessary to use an interme-diate plate with a hand pump (EPM) when for directive or technical motivations it needs to generate a pressure without the use of any other energy source. Handling the lever the spool is moved and by two relieves, it transfers a fl ow rate of oil from T line to P line. This hand pump is declared: double effect hand pump, because the fl ow is transferred whether pulling whether pushing the lever. When the pump is not used, the lever is positioned in the opening phase end-run.

It is available, on request, a longer lever. In this way the operator force to move the lever is lower.

Technical Data (for applications outside these parameters, please consult us)

GeneralWeight of the EPM (hand pump slice)

kg (lbs) 3.8 (8.4)

Weight of the extension lever kg (lbs) 0.7 (1.5)Ambient Temperature °C (°F) –20....+50 (–4....+120) [NBR seals]HydraulicMaximum resistance pressure bar (PSI) 310 (4500)Maximum generated pressure bar (PSI) 250 (3625)Total displacement cc (in3) 18 (1.08)Opening displacement cc (in3) 8.5 (0.51)Closing displacement cc (in3) 9.5 (0.57)Maximum aspiration height m (ft) 1.5 (4.92) [with pipe DN6]Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR]Permissible degree of fl uid contamination ISO 4572: βx≥75 X=12...15

ISO 4406: classe 20/18/15NAS 1638: classe 9

Viscosity range mm2/s 5....420Maximum internal leakage cc/min (in3/min) 0.2 (0.012)

PLS

T

P1LS1T1

1 2

3 2 5 4 1 5 P T

2503625

3000

2000

1000

0

200

150

100

Pre

ssur

e ∆p

50

00

0 25 50 75 100

100 200 300 400 500 N*

lbs*

Characteristic chart

1 Opening stroke 2 Closing stroke * Force applied by operator using our extension lever, length 457.5 mm (18 in.)

Hydraulic Symbol

RA 18301-30/10.11

Intermediate elements with double acting hand pump

EPM-DE-18

1/2

Page 207: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

198

Bosch Rexroth Corp. | Hydraulics EPM-DE-18 RA 18301-30/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

2/2

Ordering Details

External Dimensions and Fittings

6)

5)

4)

3)

1) 2)

7)

1 Flange specifi cations for coupling to ED intermediate elements.

2 Three through holes for coupling of the ED Directional Valve Elements. Recommended tie rods M8 with strength class DIN 8.8. Torque 20–22 Nm (16.2–17.7 ft-lb).

3 N° 2 Fixing Hole. M8. tightening torque 35–40 Nm (26–29.5 ft-lbs).

4 Optional extension lever. (See ordering code).5 Side of position of inlet plate.6 End-run lever (opening phase).7 End-run lever (closing phase).

Code Description

L88700000000000 Hand pump ED

L88700000000001 Extension lever for hand pump ED

Page 208: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

199

RA 18301-40/10.11

Stacking Modules – Pilot Operated Check

EDM-PO

1/2

Description

The secondary fl angeable elements EDM-PO-__ can be interfaced and bolted on top of the A and B ports of the ED elements of the Directional Valve Assembly.

They incorporate two Cross Piloted Check Valves which allow free fl ow toward the A and B outlet ports, and lock in a leak free mode the fl ow returning from the actuator, until suffi cient pilot pressure is built up in the opposite line and the check valve is opened.

Depending on the version selected (AB, or 0A, or 0B), the PO Check Valve is in both A and B ports, or in A port only, or in B port only (see hydraulic symbols).The Pilot Ratio is 4:1, consequently, the pilot pressure needs to be at least 1/4, or 25% of the load induced pressure in the actuator before the Check Valve opens, and oil can return to tank.

− Hydraulic port sizes: A and B – SAE 8. − Special coating and plating available, C.F.

Technical Data (for applications outside these parameters, please consult us)

General

Ambient Temperature °C (°F) –20....+50 (–4....+120)Material Aluminum

HydraulicMaximum pressure bar (PSI) 210 (3000)Maximum fl ow l/min (GPM) 60 (15)Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR]

Permissible degree of fl uid contaminationISO 4572: βx≥75 X=12...15ISO 4406: classe 20/18/15NAS 1638: classe 9

Viscosity range mm2/s 5....420

*310 bar (4500 PSI) available. Consult factory.

Circuit

= AB

= 0A

= 0B

Page 209: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

200

Bosch Rexroth Corp. | Hydraulics EDM-PO RA 18301-40/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

2/2

L 88 4A 00 00

Ordering Details

Overall Dimensions

A B

114.2[4.50]128.7[5.07]

7.2[0.28]

7.2[0.28]

58.0

[2.2

8]

45.0

[1.7

7]

30.6[1.21]

53.0[2.09]

39.6[1.56]

35.0[1.38]

5.5

[0.2

2]34

.0[1

.34]

22.5

[0.8

9]

(4) Ø0.265 drill thru & Ø0.406 C'bore x 0.275 dp.

mm[Inches]

Third angleprojection

ED directional valve element

Stacking module

Pilot operated check

Cartridge model

Check valveCheck valve for both A and B portsCheck valve for port A onlyCheck valve for port B only

= AB= 0A= 0B

0 =V =

VersionStandard

Seals in Viton

3 =Port size

SAE8

01 =05 =

Cracking pressure0.5 bar (7 PSI)

5.0 bar (75 PSI)

Page 210: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

201

RA 18301-41/10.11

Stacking Modules – Cross-over Relief

EDM-CR

1/2

Description

The secondary fl angeable elements EDM-CR-__ can be interfaced and bolted on top of the A and B ports of the ED elements of the Directional Valve Assembly.

The body consists of one direct acting pressure relief valve. The relief valve for line A releases the oil into line B and vice versa.*

The maximum secondary pressure in line A, or B, can be adjusted through the adjuster screw (3).

− Port sizes: A and B – SAE 8

− Special coating and plating available, C.F.

* A bi-directional relief is utilized for protection on A and B.

Technical Data (for applications outside these parameters, please consult us)

General

Ambient Temperature °C (°F) –20....+50 (–4....+120)Material Aluminum

HydraulicAB 0A 0B

Maximum pressure bar (PSI) 210 (3000) 210 (3000) 210 (3000)Maximum fl ow l/min (GPM) 60 (15) 50 (13) 60 (15)Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR]

Permissible degree of fl uid contamination

ISO 4572: βx≥75 X=12...15ISO 4406: classe 20/18/15NAS 1638: classe 9

Viscosity range mm2/s 5....420

*310 bar (4500 PSI) available. Consult factory.

Circuit

= AB

= 0A

= 0B

A B

A B

A B

Page 211: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

202

Bosch Rexroth Corp. | Hydraulics EDM-CR RA 18301-41/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

2/2

L 88 6A 02

Ordering Details

Overall Dimensions

ED directional valve element

Stacking module

Cross-over relief

Cartridge model

Hydraulic schemeSolenoid cartridge for both A and B portsSolenoid cartridge for port A onlySolenoid cartridge for port B only

= AB= 0A= 0B

0 =V =

VersionStandard

Seals in Viton

3 =Ports size

SAE8

00 =_ _ =

SettingStandard

Consult factory

1 =

2 =

3 =

Pressure rangeAB – 30–100 bar (435–1450 PSI)

0A or 0B – 35–140 bar (500–2000 PSI)AB – 100–210 bar (1450–3000 PSI)0A – 105–210 bar (1500–3000 PSI)0A – 175–350 bar (2500–5000 PSI)0B – 100–350 bar (1450–5000 PSI)

S =Adjustment

Screw

A B9.8

[0.39]53.0

[2.09]35.0

[1.38]18.8

[0.74]

5.5

[0.2

2]34

.0[1

.34]

22.5

[0.8

9]

45.0

[1.7

7]

72.6[2.86]

58.0

[2.2

8]

57.7[2.27]

130.2[5.13]

(4) Ø0.265 drill thru & Ø0.406 C'bore x 0.275 dp.

mm[Inches]

Third angleprojection

Page 212: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

203

RA 18301-42/10.11

Stacking Modules – Flow Control

EDM-FC

1/2

Description

The secondary fl angeable elements EDM-FC-__ can be interfaced and bolted on top of the A and B ports of the ED elements of the Directional Valve Assembly.

They incorporate two unidirectional fl ow restrictors, and, depending on the version selected (01 AB, or 02 AB), they allow free fl ow A1>A2 and B1>B2, with and controlled/restricted fl ow in the reverse directions A2>A1 and B2>B1, or vice-versa.

Also the single acting versions are available, with only one fl ow restrictor fi tted either in side A or in side B.

The restrictors are adjustable through the adjuster screw.

− Hydraulic port sizes: A and B – SAE 8.

− Special coating and plating available, C.F.

Technical Data (for applications outside these parameters, please consult us)

General

Ambient Temperature °C (°F) –20....+50 (–4....+120)Material Aluminum

HydraulicMaximum pressure bar (PSI) 210 (3000)*Maximum fl ow l/min (GPM) 60 (15)Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR]

Permissible degree of fl uid contaminationISO 4572: βx≥75 X=12...15ISO 4406: classe 20/18/15NAS 1638: classe 9

Viscosity range mm2/s 5....420

*310 bar (4500 PSI) available. Consult factory.

Circuit

= 01AB

= 010A

= 010B

= 02AB

= 020A

= 020B

Page 213: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

204

Bosch Rexroth Corp. | Hydraulics EDM-FC RA 18301-42/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

2/2

L 88 5A 2 00

Ordering Details

Overall Dimensions

ED directional valve element

Stacking module

Flow control with reverse check

CircuitMeter-outMeter-in

= 01_ _= 02_ _

0 =V =

VersionStandard

Seals in Viton

3 =Ports size

SAE8

2S =2K =

AdjustmentScrewKnob

A B

58.0

[2.2

8]

45.0

[1.7

7]

30.6[1.21]

53.0[2.09]

39.6[1.56]

35.0[1.38]

5.5

[0.2

2]34

.0[1

.34]

22.5

[0.8

9]

(4) Ø0.265 drill thru & Ø0.406 C'bore x 0.275 dp.

39.3[1.55]

51.7[2.04]

114.2[4.50]

51.7[2.04]

217.7[8.57]

mm[Inches]

Third angleprojection

Page 214: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

205

RA 18301-43/10.11

Stacking Modules – Counterbalance

EDM-CB

1/2

Description

The secondary fl angeable elements EDM-CB-__ can be interfaced and bolted on top of the A and B ports of the ED elements of the Directional Valve Assembly.

They incorporate one or two Cross Piloted Counterbalance Valves which allow free fl ow toward the A and B outlet ports, and lock in a leak free mode the fl ow returning from the actuator. Pilot pressure in the opposite line reduces the pres-sure setting of the counterbalance valve in proportion to the pilot ratio until open-ing and allowing the fl ow return from the actuator.

The pressure setting should be at least 1.3 times the highest expected load.Depending on the version selected, the counterbalance function can be double-acting or single-acting in both A and B ports, or in A port only, or in B port only (see hydraulic symbols).

− Port sizes: A and B – SAE 8.

− Special coating and plating available, C.F.

Technical Data (for applications outside these parameters, please consult us)

General

Ambient Temperature °C (°F) –20....+50 (–4....+120)Material Aluminum

HydraulicMaximum pressure bar (PSI) 210 (3000)Maximum fl ow l/min (GPM) 60 (15)Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR]

Permissible degree of fl uid contaminationISO 4572: βx≥75 X=12...15ISO 4406: classe 20/18/15NAS 1638: classe 9

Viscosity range mm2/s 5....420

*310 bar (4500 PSI) available. Consult factory.

Circuit

= AB

= 0A

= 0B

Page 215: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

206

Bosch Rexroth Corp. | Hydraulics EDM-CB RA 18301-43/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

2/2

L 8 8 3 5 A 2

Ordering Details

Circuit Type

Overall Dimensions

ED directional valve element

Stacking module

Counterbalance

Hydraulic schemeCounterbalance valve for both A and B portsCounterbalance valve for port A onlyCounterbalance valve for port B only

= AB= 0A= 0B

Pressure range35–105 bar (500–1500 PSI) only for S315–175 bar (350–2500 PSI) only for V370–210 bar (1000–3000 PSI)*140–350 bar (2000–5000 PSI)**

= 10= 15= 20= 35

0 =Version

Standard

3 =Ports SAE8

R4 =R9 =S1 =S3 =S8 =C3 =V3 =

Circuit type***VBSN-08UU, 4:1 pilot ratioVBSN-08UU, 9:1 pilot ratioVBSN-08U, 1.5:1 pilot ratio

VBSN-08U, 3:1 pilot ratioVBSN-08U, 8:1 pilot ratioVBSP-08U, 3:1 pilot ratioVBST-08U, 3:1 pilot ratio

* If R4, R9, or V3 = 70–280 bar (1000–4000 PSI)** Not available for R4, R9, or V3*** See data sheets on page 211 for further detail.

A B

163.8[6.45]

44.0[1.73]

44.0[1.73]

251.9[9.92]

58.0

[2.2

8]

45.0

[1.7

7]

55.4[2.18]

64.4[2.54]

53.0[2.09]35.0

[1.38]

5.5

[0.2

2]34

.0[1

.34]

22.5

[0.8

9]

(4) Ø0.265 drill thru & Ø0.406 C'bore x 0.275 dp.

mm[Inches]

Third angleprojection

VBSN-08UU = R

Restricted

VBSN-08U = S

Standard

VBSP-08U = C

Compensated

VBST-08U = V

Vented

Page 216: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

207

RA 18301-45/01.13Replaces: 10.11

Flangeable elements with single or double secondary pressure relief valves and anti-cavitation function

EDCM/EDCMF-VM

1/4

Description

These modular secondary elements can be fl ange mounted on top of the EDC elements machined with the interfacing surface.

They let through free fl ow to the A (or B) port until pressure increases and reach-es the selected pressure setting; then they release fl ow into the Tank channels.

The direct acting relief cartridges are designed for quick response and stable pressure control; they also incorporate a reverse fl ow check for anti-cavitation.

With a body made of zinc plated cast iron, these elements combine secondary pressure relief and dual cross-over, with anti-cavitation function.

Technical Data (for applications outside these parameters, please consult us)

General

Weight kg (lbs) 0.6 (1.3)Ambient Temperature °C (°F) –20....+50 (–4....+120) [NBR seals]

HydraulicMaximum pressure bar (PSI) 310 (4500)Maximum fl ow l/min (GPM) 30 (7.93)Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR]

Permissible degree of fl uid contaminationISO 4572: βx≥75 X=10...12ISO 4406: classe 19/17/14NAS 1638: classe 8

Viscosity range mm2/s 5....420

B

Pressure relief valvesand anti-cavitation function

Only anti-cavitation function

T

A

B

T

A

Page 217: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

208

Bosch Rexroth Corp. | Hydraulics EDCM/EDCMF-VM RA 18301-45/01.132/4

Characteristic Curves

Measured with hydraulic fl uid ISO-VG32 at 45° ± 5° C [113° ± 9° F]; ambient temperature 20° C [68° F].

Hydraulic – Symbol

Pressure relieving Pressure drop (anticavitation)

psi435400

300

200

100

00 5 10 15 20 25 30 l/min

0 1 2 3 4 5 6 7 7.9 gpm

bar30

25

20

15

10

5

0

Flow-Q

Pressure drop misured with EDC valveL8580_2S9000000M000

Pre

ssur

e-p

0 10 20 30 l/min

0 1 2 3 4 5 6 7 7.9 gpm

Flow-Q

3

2

1

bar300

250

200

150

100

50

0

psi43514000

3000

2000

1000

0

Pre

ssur

e-p

Example Curve No.

Example of setting 100 bar – 5 l/min [1450 psi – 1.32 gpm] 1

Example of setting 150 bar – 5 l/min [2175 psi – 1.32 gpm] 2

Example of setting 250 bar – 5 l/min [3626 psi – 1.32 gpm] 3

B

T

A

AB_ _

0A_0

0B0_

AB99

0A90

AB9_

AB_9

0B09

B

T

A

B

T

A

B

T

A

B

T

A

B

T

A

B

T

A

B

T

A

Page 218: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

209

RA 18301-45/01.13 EDCM/EDCMF-VM Hydraulics | Bosch Rexroth Corp. 3/4

External Dimensions and Ports

1 Four through holes 5.5mm [0.217 inch] for screws and tighten-ing torques see data sheet RE 18301-90.

2 A and B ports.

3 Identifi cation label.

4 Machined for interfacing to modular elements (=M ports version).

Page 219: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

210

Bosch Rexroth Corp. | Hydraulics EDCM/EDCMF-VM RA 18301-45/01.13

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

4/4

L 85 65 00 0

Ordering Details

FamilyDirectional Valve

ModelFlangeable element for EDC valves

TypeFlangeable elements with secondary pressure relief valves and anti-cavitation functions

CongfigurationCavity for cartridge for both A and B portsCavity for cartridge for port A onlyCavity for cartridge for port B only

= 01AB= 010A= 010B

0 =2 =3 =M =

PortsG 3/8 DIN 3852G 1/2 DIN 3852

3/4“ – 16 UNF – SAE8Machined for interfacing to

modular elements

A_X =

9 =

Cartridge for B sideRelief valve setting A side Q = 5 l/min [1.3gpm]

Ex. Setting at 5 l/min 20 bar (see table below)Check valve (on B side)

A_X =

9 =

Cartridge for A sideRelief valve setting A side Q = 5 l/min [1.3gpm]

Ex. Setting at 5 l/min 20 bar (see table below)Check valve (on A side)

A B C D E F G H I J K L M N O P Q R S T U V W X

20bar

30bar

40bar

50bar

60bar

70bar

80bar

90bar

100bar

110bar

120bar

130bar

140bar

150bar

160bar

170bar

180bar

190bar

200bar

210bar

220bar

230bar

240bar

250bar

290psi

435psi

580psi

725psi

870psi

1015psi

1160psi

1305psi

1450psi

1595psi

1740psi

1885psi

2030psi

2175psi

2320psi

2465psi

2611psi

2756psi

2901psi

3046psi

3191psi

3336psi

3481psi

3626psi

Page 220: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

211

RA 18301-47/01.13

Flangeable elements with secondary pressure relief valves single or double

EDCM/EDCMF-VM5

1/4

Description

These modular secondary elements can be fl ange mounted on top of the EDC elements machined with the interfacing surface.

They let through free fl ow to the A (or B) port until pressure increases and reaches the pressure setting; then they release fl ow into the Tank channels (T).

The maximum secondary pressure in line A, or B, can be adjusted through the adjuster screw (2).

The body (1) is made of Yellow Zinc Plated ( Cr+3) Cast Iron (CI). Hydraulic Ports A2 and B2 are size G3/8 and G1/2; with the modular version (M) is possible to fl ange the others type of EDCM-modular-elements available.

Technical Data (for applications outside these parameters, please consult us)

General

Weight kg (lbs) 2.0 (4.4)Ambient Temperature °C (°F) –20....+50 (–4....+120) [NBR seals]

HydraulicMaximum pressure bar (PSI) 310 (4500)Maximum fl ow l/min (GPM) 50 (13.2)Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR]

Permissible degree of fl uid contaminationISO 4572: βx≥75 X=10...12ISO 4406: classe 19/17/14NAS 1638: classe 8

Viscosity range mm2/s 5....420

Hydraulic – Symbol

A2

2

1

B2

A1 B1

A

T

0A

B

A

T

0B

B

A

T

AB

B

Page 221: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

212

Bosch Rexroth Corp. | Hydraulics EDCM/EDCMF-VM5 RA 18301-47/01.132/4

Characteristic Curves

Measured with hydraulic fl uid ISO-VG32 at 45° ± 5° C [113° ± 9° F]; ambient temperature 20° C [68° F].

External Dimensions and Ports

L85_ _ AB version

Example Curve No.

VMD1040SN set at 120 bar at 5 l/min [1740 psi at 1.32 gpm] 1

VMD1040SB set at 200 bar at 5 l/min [2900 psi at 1.32 gpm] 2

VMD1040SV set at 250 bar at 5 l/min [3625 psi at 1.32 gpm] 3

psi5000

4000

3000

2000

1000

00 10 20 30 40 50 l/min

0 2 4 6 8 10 12 13.2 gpm

bar

3

2

1

350

250

300

200

150

100

50

0

Flow-Q

0 10 20 30 40 50 60 70 l/min

0 2 4 6 8 10 12 14 16 18.5 gpmFlow-Q

Pre

ssur

e-p

psi120

80

60

40

20

0

bar

7

5

6

4

3

2

1

0

Pre

ssur

e-p

Pressure relieving Pressure drop of the modular element alone

Page 222: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

213

RA 18301-47/01.13 EDCM/EDCMF-VM5 Hydraulics | Bosch Rexroth Corp. 3/4

External Dimensions and Ports

L85_ _ 0A version

1 Four through holes Ø 5.5 mm [0.216 inch] for screws and tightening torques see data sheet RE 18301-90.

2 Pressure relief cartridge with adjuster screw VMD1040 refer to RE 18301-91.

3 A and B ports for the actuator.

4 Identifi cation label.5 Adjuster screw.: 5mm [0.2 inch].6 Machined for interfacing to modular elements

(= M ports version).

L85_ _ 0B version

Page 223: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

214

Bosch Rexroth Corp. | Hydraulics EDCM/EDCMF-VM5 RA 18301-47/01.13

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

4/4

L 8 5 6 1 0 0

Ordering Details

FamilyDirectional Valve

ModelFlangeable element for EDC valves

TypeFlangeable elements with secondary pressure relief valves and anti-cavitation functions

CongfigurationPressure relief for both A and B portsPressure relief for port A onlyPressure relief for port B only

= 05AB= 050A= 050B

0 =2 =M =

PortsG 3/8 DIN 3852G 1/2 DIN 3852

Machined for interfacing to modular elements

0 =N =B =V =

Pressure range on port BNot present

25–120 bar (360–1740 psi)40–200 bar (580–2900 psi)

150–350 bar (2175–5075 psi)

0 =N =B =V =

Pressure range on port ANot present

25–120 bar (360–1740 psi)40–200 bar (580–2900 psi)

150–350 bar (2175–5075 psi)

S =Pressure adjustment

Relief cartridge with adjuster screw

Page 224: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

215

RA 18301-46/01.13

Flangeable elements with single or double acting cross piloted check valves

EDCM/EDCMF-VR

1/4

Description

These secondary fl angeable elements can be interfaced and bolted on top of the A and B ports of the ED elements of the directional valve assembly.

They incorporate two cross piloted check valve which allow free fl ow toward the A and B outlet ports, and lock in a leak free mode the fl ow returning from the actuator, until suffi cient pilot pressure is built up in the opposite line and the check valve in opened.

Depending on the version selected (AB, or 0A, or 0B), the PO check valve is in both A and B ports, or in A port only, or in B port only (see hydraulic symbols).

The pilot ratio in 3:1, consequently, the pilot pressure needs to be at least 1/3, or 33% of the load induced pressure in the actuator before Check Valve opens, and oil can return to tank.

The body of these elements in made of Yellow Zinc Plated (Cr+3) Cast Iron (CI). Hydraulic Ports A2 and B2 are size G3/8 or G1/2 or 3/4-16 UNF 2-B (SAE8).

Technical Data (for applications outside these parameters, please consult us)

General

Weight kg (lbs) 2.0 (4.4)Ambient Temperature °C (°F) –20....+50 (–4....+120) [NBR seals]

HydraulicMaximum pressure bar (PSI) 310 (4500)Maximum fl ow l/min (GPM) 70 (18.5)Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR]

Permissible degree of fl uid contaminationISO 4572: βx≥75 X=10...12ISO 4406: classe 19/17/14NAS 1638: classe 8

Viscosity range mm2/s 5....420

Hydraulic – Symbol

A2 B2

A1A B

B1

A

AB

B

A

0A

B

A

0B

B

Page 225: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

216

Bosch Rexroth Corp. | Hydraulics EDCM/EDCMF-VR RA 18301-46/01.132/4

Characteristic Curves

Measured with hydraulic fl uid ISO-VG32 at 45° ± 5° C [113° ± 9° F]; ambient temperature 20° C [68° F].

Cracking pressure Curve No.

5 bar [72.5 psi] free fl ow either A1 > A2 or B1> B2 1

0.5 bar [7.3 psi] free fl ow either A1 > A2 or B1> B2 2

Returning fl ow, fully piloted, either A2 > A1 or B2 > B1 3

290

psi

Pre

ssur

e –

p

240

180

120

60

0

20

bar

16

12

8

4

00

0

1

3

2

2 4 6 8Flow – Q

10 12 14 16 18 gpm

10 20 30 40 50 60 70 l/min

Page 226: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

217

RA 18301-46/01.13 EDCM/EDCMF-VR Hydraulics | Bosch Rexroth Corp. 3/4

External Dimensions and Fittings

1 Four through holes Ø 5.2 mm [0.205 inch] for screws and tightening torques see data sheet RE 18301-90.

2 A and B ports for the actuator.

3 Identifi cation label.4 Machined for interfacing to modular elements

(= M ports version).

Page 227: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

218

Bosch Rexroth Corp. | Hydraulics EDCM/EDCMF-VR RA 18301-46/01.13

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

4/4

L 8 5 4 1 0 0 0

Ordering Details

FamilyDirectional Valve

ModelFlangeable element for EDC valves

TypeCross piloted check valves

CongfigurationPressure relief for both A and B portsPressure relief for port A onlyPressure relief for port B only

= 00AB= 000A= 000B

Additional fixturesStandard

0 =2 =3 =M =

PortsG 3/8 DIN 3852G 1/2 DIN 3852

3/4-16 UNF 2-B (SAE 8)Machined for interfacing to

modular elements

01 =05 1) =

Cracking pressure0.5 bar (7.3 psi)5 bar (72.5 psi)

1) Recommended version for EDC-P (RE 18301-09)

Page 228: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

219

Description

The exit plate TC… is employed as end plates to plug the P and T channels of the ED element of the Directional Valve Assembly, or to provide an extra port for P, T, or P and T. Port sizes are available in SAE 6 and SAE 8.

Technical Data (for applications outside these parameters, please consult us)

General

Weight (w/o ports & SAE 6) kg (lbs) 0.3 (0.66)

Weight (SAE 8) kg (lbs) 0.5 (1.10)

Ambient Temperature °C (°F) –20....+50 (–4....+120) [NBR seals]

Hydraulic

Maximum pressure (TC0000) bar (PSI) 250 (3600)*

Maximum pressure bar (PSI) 210 (3000)*

Maximum fl ow l/min (GPM) 60 (15)

Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR seals]

Permissible degree of fl uid contamination

ISO 4572: bx≥75 X=12...15ISO 4406: classe 20/18/15NAS 1638: classe 9

Viscosity range mm2/s 5....420

*310 bar (4500 PSI) available – consult factory

Hydraulic Symbol

Without ports = 00

With T port = 01

T

With P port = 02

P

With P and T ports = 03

T

P

RA 18301-60/10.11

Exit Plate –Basic

TC-...

1/2

Page 229: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

220

Bosch Rexroth Corp. | Hydraulics TC RA 18301-60/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

2/2

Tightening torques

External dimensions and fittings

T C _ _ _ _

Ordering Details

14.48[0.57]

11.4

3[0

.45]

A

29.98[1.18]

BC 74

.93

[2.9

5]

74.93[2.95]

M6

T

P

11.4

3[0

.45]

14.48[0.57]

29.98[1.18]

M6

A

74.93[2.95]

74.9

3[2

.95]

B

28.70[1.13]

14[0

.55]

27.6

7[1

.09]

For ports SAE 8

BracketsN°2 M6x12: 9+10 Nm (6.5–7.5 lb-ft.)

Tie RodsN°3 M8: 17–19 Nm (12.5–14 lb-ft.)

Model PortsP-T

Max. fl owl/min (GPM)

Max. operating pressure* – bar (PSI) A B C Weights

kg (lbs.)

TC0000 — — 250 (3600) 22 — — 0.3 (0.66)

TC0155 SAE6 30 (8) 210 (3000) 22 14 — 0.3 (0.66)

TC0255 SAE6 30 (8) 210 (3000) 22 41.7 — 0.3 (0.66)

TC0355 SAE6 30 (8) 210 (3000) 22 14 27.7 0.3 (0.66)

TC0177 SAE8 60 (15) 210 (3000) 22 34 — 0.5 (1.1)

TC0277 SAE8 60 (15) 210 (3000) 22 34 — 0.5 (1.1)

Aluminum body. * 310 bar (4500 PSI) available – consult factory

FamilyExit plate

Hydraulic scheme (see page 1)Without portsWith port TWith port PWith ports P & T (only available with Ports SAE 6)

= 00= 01= 02= 03

00 =55 =77 =

PortsWithout ports

SAE 6SAE 8

Page 230: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

221

Description

The outlet elements TC-04-__ are employed to connect the P and T channels of the ED elements of the Directional Valve Assembly to the P1 and T1 ports for downstream operators. They incorporate a pressure relief cartridge which controls the maximum pressure in the P1 line. The relief setting can be checked through the Test Point port M.

The TC-04-__ elements are available with body made of Black Anodized Alumini-um (Al).

Hydraulic Ports P1 and T1 are size G 3/8, and Test Point port (M) is G 1/4.

Technical Data (for applications outside these parameters, please consult us)

General

Weight kg (lbs) 0.31 (0.67)

Weight kg (lbs) 0.44 (0.96)

Ambient Temperature °C (°F) –20....+50 (–4....+120)

Hydraulic

Maximum pressure bar (PSI) 250 (3625)

Maximum fl ow l/min (GPM) 35 (9.2)

Hydraulic fl uidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:

Mineral oil based hydraulic fl uids HL (DIN 51524 part 1). Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2). For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.

Fluid Temperature °C (°F) –20....+80 (–4....+176) [NBR seals]

Permissible degree of fl uid contamination

ISO 4572: bx≥75 X=12...15ISO 4406: classe 20/18/15NAS 1638: classe 9

Viscosity range mm2/s 5....420

Hydraulic Symbol

P1

M1

P

T

T1

RA 18301-64/10.11

Outlet elements with pressure reilief valve and with P, T, and M ports for downstream operators

TC-04

1/2

Page 231: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

222

Bosch Rexroth Corp. | Hydraulics TC-04 RA 18301-64/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

2/2

External dimensions and fittings

Ordering Details

1) 2)

5)

4)3)

T C - 0 4 - _ _ - _ _ - A L

FamilyOutlet Elements

ConfigurationWith Pressure Relief Valve and through ports P and T

PortsG 3/8 DIN 3852 = 02

MaterialAluminium

00 =SN =SB =SV =

Pressure Relief range Without pressure relief valve

25–125 bar (362–1813 PSI)40–200 bar (580–2900 PSI)

200–350 bar (2900–5076 PSI)

1 Flange specifi cations for coupling to the ED Directional Valve Elements.

2 Three through holes 8.5 mm DIA (0.335 in.) for coupling of the ED Directional Valve Elements.

3 Hydraulic Ports P1 and T1 size G 3/8 for downstream operators.

4 Test Point port (M) G 1/4…5 Pressure Relief Cartridge VMD1025, with screw type adjuster

(refer to RE 18301-91).

Page 232: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

223

Summary

Description Page

Assembly of directional elements 2

Fitting of mounting brackets 3

Fitting of secondary elements 3

Flow restrictors 4

Series circuits 5

Pressure drop through elements 5

Universal seal kit 5

RA 18301-90/10.11

Accessories and fixation elements

1/6

Page 233: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

224

Bosch Rexroth Corp. | Hydraulics Accessories and fi xation elements RA 18301-90/10.112/6

Assembly of directional elements

Total fl angeableelements

Screw or tie-rod length (L)

mm (inch)Tightening torque

Nm (ft-lb) Reference code Type Material Number

1 80 (3.150) 17–19 (12.5–14) K-2201 Screw R933003721

2 125 (4.921) 17–19 (12.5–14) K-2202 Screw R933003722

3 185 (7.283) 17–19 (12.5–14) K-2203 Tie-rod R933003723

4 230 (9.055) 17–19 (12.5–14) K-2204 Tie-rod R933003724

5 275 (10.827) 17–19 (12.5–14) K-2205 Tie-rod R933003725

6 320 (12.598) 17–19 (12.5–14) K-2206 Tie-rod R933003726

7 365 (14.370) 17–19 (12.5–14) K-2207 Tie-rod R933003727

8 410 (16.142) 17–19 (12.5–14) K-2208 Tie-rod R933003728

9 460 (18.110) 17–19 (12.5–14) K-2209 Tie-rod R933003729

10 510 (20.079) 17–19 (12.5–14) K-2210 Tie-rod R933000000

For 1 or 2 elements, the assembly kit is composed by 3 screws and 3 washers

For 3 or more elements, the assembly kit is composed by 3 tie-rods, 3 washers and 3 nuts

Page 234: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

225

RA 18301-90/10.11 Accessories and fi xation elements Hydraulics | Bosch Rexroth Corp. 3/6

Assembling of flangeable element

Fitting of mounting brackets

Total fl angeable elements

Screw or tie-rod length (L)

mm (inch)Tightening torque

Nm (ft-lb) Reference code Material Number

1 60 (2.326) 9-10 (6.64-7.37) K-2221A R987281101

2 120 (4.724) 9-10 (6.64-7.37) K-2222A R987281102

Note:

The kit is composed by 2 brackets, 4 screws, and 4 washers

TypeTightening torque

Nm (ft-lb) Material Number

K-2215 9-10 (6.64-7.37) R933003730

K-2216 9-10 (6.64-7.37) R933007089

K-2217 9-10 (6.64-7.37) R933007514*

Note:

The assembly kit is composed by 4 screws and 4 washers.

Note:

The kit is composed by 1 bracket, 2 screws, and 2 washers.* To be used with TI-M412

Page 235: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

226

Bosch Rexroth Corp. | Hydraulics Accessories and fi xation elements RA 18301-90/10.114/6

Material description Orifi ce I.D. mm (inch) Material Number

50-04999 Closed R933002917

50-05003 0.3 (0.012) R933002922

50-05004 0.4 (0.016) R933003398

50-05001 0.5 (0.020) R933002920

50-05000 0.6 (0.024) R933002919

50-05002 0.7 (0.028) R933002921

50-0500 0.8 (0.031) R933002918

50-05008 0.9 (0.035) R933002923

50-0501 1.0 (0.039) R933002924

50-05015 1.1 (0.043) R933002925

50-0502 1.2 (0.047) R933002926

50-05022 1.35 (0.053) R933002927

50-0503 1.5 (0.059) R933002928

50-05032 1.6 (0.063) R933002930

50-05031 1.7 (0.067) R933002929

50-0504 2.0 (0.079) R933002931

50-0505 2.2 (0.087) R933002933

50-05045 2.5 (0.098) R933002932

50-0506 3.0 (0.118) R933002934

50-0508 3.2 (0.126) R933002935

Flow restrictor

Material description Orifi ce I.D. mm (inch) Material Number

50-07000 Closed R933002936

50-07020 0.8 (0.031) R933002937

50-07021 1.0 (0.039) R933007090

50-07030 1.6 (0.063) R933002938

50-07031 1.7 (0.067) R933007091

50-07040 2.0 (0.079) R933002939

50-07047 2.75 (0.108) R933002940

50-07050 3.0 (0.118) R933002941

Kit for spacers between elements

The spacers (code 44-00257012) are fi tted in order to install longer tie-rods for future insertion of an extra directional element.

Page 236: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

227

RA 18301-90/10.11 Accessories and fi xation elements Hydraulics | Bosch Rexroth Corp. 5/6

M A

PT

B A B

T1

P

T

T1 P

T T1

T1

M A

PT

B A BA B

T1T1

To have information about the pressure drops on elements, see the (DELTA P-Q) curves of P>T of A201 circuit of ED1 (RE 18301-01) or ED2 (RE 18301-02) modular elements.

Flangeable elements in even number Flangeable elements in odd number

Universal seal kit

Series circuits

Universal Seal Kit – includes o-rings for one inlet plate and one stacking module OR one directional element and one stacking module. Universal seal kits can be applied to any Bankable component type or size.

Description Number Material Number

Seal kit K-1000A R987367243

Cartridge seal kits ordered separately. See data sheets page 211.Directional element solenoid tube coil nuts and seals ordered separately, C.F.

Page 237: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

228

Bosch Rexroth Corp. | Hydraulics Accessories and fi xation elements RA 18301-90/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

6/6

Page 238: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Contents

Description Model Page

Relief Valves

Direct acting poppet type VS-5 213

Direct acting guided poppet type VSBN-10A 215

Direct acting poppet type differential area VSDN-10A 217

Bi-directional direct acting poppet type differential area

VSNG-10A 219

Pilot operated spool type VSPN-10A 221

Pressure Reducing/Relieving

Direct acting spool type VRPR-10A 223

Pilot operated spool type VRPX-10A 225

Direction Valves

Check valve poppet type VUCN-10A 227

Flow Control Valves

Needle restrictor, free reverse fl ow STVU-10A 229

3-way pressure compensated fl ow control, combination type fi xed setting

VRFC-12A-TF 231

3-way pressure compensated fl ow control, combination type fully adjustable

VRFD-12A 233

Logic Valves

Flow and pressure control with external pilot

VLST-10A 235

Description Model Page

Counterbalance

Standard guided poppet type, counterclockwise adjustment

VBSN-08UU-RS 237

Standard poppet type, differential area, counterclockwise adjustment

VBSN-08U-RS 239

Relief compensated poppet type, differ-ential area, counterclockwise adjustment

VBSP-08U-RS 241

Vented guided poppet type, counterclockwise adjustment

VBST-08U-RS 243

2-way Solenoid Operated Valves

Pilot operated poppet type, Normally closed, Size 08

VEI-8A-06-NC 245

Pilot operated poppet type,Normally open, Size 08

VEI-8A-06-NA 249

Pilot operated poppet type, Normally open, Size 10

VEI-8A-10-NA 253

Pilot operated poppet type,Normally closed, Size 10

VEI-8A-10-NC 257

Proportional Valves

Non-compensated fl ow regulator VEP-5A-2Q-09 261

Coils

2-way continuous duty, Class H S8-356 265

Proportional continuous duty, Class H S5 267

Cartridge Valves

RA 18301-91/10.11

229

Page 239: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

231

1/2

Description

Flow is blocked from 1 to 2 until pressure increases to meet the selected valve setting, lifting the poppet from its seat and allowing relief fl ow through 2 to tank. Pressure at 2 is additive to the relief setting of the valve. The cartridge is suitable only for pilot or thermal relief applications.

Technical Features

Max. operating pressure bar (psi) 460 (6600)

Max. fl ow l/min. (gpm) 1.5 (0.4)

Max. internal leakage (*) drops/min. 15

Fluid temperature range °C (°F) –30 to 100 (–22 to 212)

Installation torque Nm (ft-lbs) 27-33 (20-24)

Weight kg (lbs) 0.05 (0.11)

Special cavity 348see data sheet RE 18325-75

Seal kit (**) codematerial no.

RG0348010520100R930001669

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 10 to 500 mm2/s (cSt)

Filtration Nominal value max. 10μm (NAS 8)ISO 4406 19/17/14

Installation No restrictions

Other Technical Data See data sheet RE 18350-50

(*) at 80% of pressure setting(**) Only external seals for 10 valves

Performance

Relief, direct acting poppet type

Special cavity, 348

VS-5-CN 04.11.58 - X - 99 - Z

RA 18318-19/10.11

Page 240: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics 041158X99Z RA 18318-19/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

232

232/2

Type Material number

04115803991000A R901098796

041158039920000 R901113594

041158039935000 R901113597

041158039946000 R901098895

Type Material number

Dimensions

Ordering code

Series 0/A to L unchanged performances and dimensions

Relief, direct acting poppet type Version and options standard

SPRINGS

Adjustments Adj. press. rangebar (psi)

Pressure increasebar/turn(psi/turn)

Std. settingbar (psi)

cracking pressure= 03 Leakproof hex. socket screw= 10 25-100 (350-1450) 40 (580) 100 (1450)

Special cavity, 348 = 20 100-200 (1450-2900) 73 (1059) 200 (2900)= 35 200-350 (2900-5000) 167 (2422) 350 (5000)= 46 350-460 (5000-6600) 228 (3306) 350 (5000)

Note: Special settings available. Contact factory authorized representative for ordering code

04.11.58 X 99 Z 00 *

Leakproof hex. socket screw

OPTIONTamper resistant capordering code 11.04.31.001Mat. no. R930000777

Page 241: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

233

1/2

Description

Flow is blocked from 1 to 2 until pressure increases to meet the selected valve setting, lifting the poppet from its seat and allowing relief fl ow through port 2 to tank. Pressure at port 2 is additive to the relief setting of the valve. The unique Bosch Rexroth Oil Control poppet design provides enhanced stability at all fl ows and pressures.

Technical Features

Max. operating pressure port 1 (P)

bar (psi) 350 (5000)

Max. pressure admitted port 2 (T)

bar (psi) 350 (5000)

Max. fl ow l/min. (gpm) 50 (13)

Max. internal leakage (*) drops/min. 15

Fluid temperature range °C (°F) –30 to 100 (–22 to 212)

Installation torque Nm (ft-lbs) 41-47 (30-35)

Weight kg (lbs) 0.2 (0.44)

Cavity CA-10A-2Nsee data sheet RE 18325-70

Line bodies See data sheet RE 18325-85

Seal kit (**) codematerial no.

RG10A2010530100R901111366

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 10 to 500 mm2/s (cSt)

Filtration Nominal value max. 10μm (NAS 8)ISO 4406 19/17/14

Installation No restrictions

Other Technical Data See data sheet RE 18350-50

(*) Max. to 80% of nominal setting(**) Only external seals for 10 valves

Performance

Relief, direct acting guidedpoppet type

Common cavity, Size 10

VSBN-10A 04.11.55 - X - 85 - Z

RA 18318-05/10.11

Page 242: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics 041155X85Z RA 18318-05/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

234

234/2

Type Material number 041155038505000 R901191831

041155038510000 R901113609

041155038520000 R901113610

041155038535000 R901115702

Type Material number

Dimensions

Ordering code

Leakproof hex. socket screw

OPTIONTamper resistant capOrdering code 11.04.23.002Mat. no. R930000752

Series 0/A to L unchanged performances and dimensions

Relief, direct acting guided poppet type Version and options standard

SPRINGS

AdjustmentsAdj. press. range

bar (psi)Pressure increasebar/turn (psi/turn)

Std. settingbar (psi)

Q=5 l/min.= 03 Leakproof hex. socket screw

= 05 5-70 (75-1000) (*) 16 (232) 50 (725)

Common cavity, Size 10 = 10 35-140 (500-2000) 24 (348) 100 (1450)

= 20 105-210 (1500-3000) 54 (783) 200 (2900)

= 35 175-350 (2500-5000) 84 (1218) 350 (5000)

Note: Special settings available. Contact factory authorized representative for ordering code (*) minimum pressure setting intended with Q=5 l/min. (1.3 gpm)

04.11.55 X 85 Z 00 *

Page 243: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

235

1/2

Description

Flow is blocked from 2 to 1 until pressure increases to meet the selected valve setting, lifting the poppet from its seat and allowing relief fl ow through port 1 to tank. Pressure at port 1 is additive to the relief setting of the valve. The unique Bosch Rexroth Oil Control poppet design provides enhanced stability at all fl ows and pressures.

Technical Features

Max. operating pressure port 2 (P)

bar (psi) 350 (5000)

Max. pressure admitted port 1 (T)

bar (psi) 140 (2000)

Max. fl ow l/min. (gpm) 120 (32)

Max. internal leakage (*) drops/min. 15

Fluid temperature range °C (°F) –30 to 100 (–22 to 212)

Installation torque Nm (ft-lbs) 41–47 (30–35)

Weight kg (lbs) 0.2 (0.44)

Cavity CA-10A-2Nsee data sheet RE 18325-70

Line bodies See data sheet RE 18325-85

Seal kit (**) codematerial no.

RG10A2010520100R901111363

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 10 to 500 mm2/s (cSt)

Filtration Nominal value max. 10μm (NAS 8)ISO 4406 19/17/14

Installation No restrictions

Other Technical Data See data sheet RE 18350-50

(*) Max. to 80% of nominal setting(**) Only external seals for 10 valves

Performance

Relief, direct acting poppet typedifferential area

Common cavity, Size 10

VSDN-10A 04.15.23 - X - 85 - Z

RA 18318-03/10.11

Page 244: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics 041523X85Z RA 18318-03/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

236

2/2

Type Material number 041523038510000 R930005643

041523038535000 R930005644

Type Material number

Dimensions

Ordering code

Leakproof hex. socket screw

OPTIONTamper resistant capOrdering code 11.04.23.002Mat. no. R930000752

Series 0/A to L unchanged performances and dimensions

Relief, direct acting poppet type differential area Version and options standard

SPRINGS

AdjustmentsAdj. press. range

bar (psi)

Pressure increasebar/turn(psi/turn)

Std. settingbar (psi)

(Q=5 l/min)= 03 Leakproof hex. socket screw

= 10 35-140 (500-2000) 46 (667) 100 (1450)

Common cavity, Size 10 = 35 100-350 (1450-5000) 86 (1247) 350 (5000)

Note: Special settings available. Contact factory authorized representative for ordering code

04.15.23 X 85 Z 00 *

Page 245: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

237

1/2

Description

Flow is blocked bi-directionally between 1 and 2 until pressure at either port increases to meet the selected valve setting, lifting the poppet from its seat and allowing relief fl ow to the opposite port. The unique Bosch Rexroth Oil Control poppet design provides consistent cracking pressures at both ports and enhanced stability at all fl ows and pressures. Maximum difference for crack pressure in both direction: 10 bar (145 psi).

Technical Features

Max. operating pressure port 1 (P)

bar (psi) 240 (3500)

Max. pressure admitted port 2 (T)

bar (psi) 240 (3500)

Max. fl ow l/min. (gpm) 56 (15)

Max. internal leakage (*) cm3/min.(cu.in./min.)

30(1.8)

Fluid temperature range °C (°F) –30 to 100 (–22 to 212)

Installation torque Nm (ft-lbs) 41–47 (30–35)

Weight kg (lbs) 0.25 (0.55)

Cavity CA-10A-2Nsee data sheet RE 18325-70

Line bodies See data sheet RE 18325-85

Seal kit (**) codematerial no.

RG10A2010530100R901111366

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 10 to 500 mm2/s (cSt)

Filtration Nominal value max. 10μm (NAS 8)ISO 4406 19/17/14

Installation No restrictions

Other Technical Data See data sheet RE 18350-50

(*) Measured at 200 bar (2900 psi)(**) Only external seals for 10 valves

Performance

Relief, bi-directional direct acting poppet type differential area

Common cavity, Size 10

VSNG-10A 04.11.59 - X - 85 - Z

RA 18318-07/10.11

Page 246: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics 041159X85Z RA 18318-07/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

238

2/2

Type Material number 041159038510000 R901109725

041159038520000 R901109726

Type Material number

Dimensions

Ordering code

Leakproof hex. socket screw

Series 0/A to L unchanged performances and dimensions

Relief, bi-directional direct acting poppet type differential area Version and options standard

SPRINGS

AdjustmentsAdj. press. range

bar (psi)

Pressure increasebar/turn(psi/turn)

Std. settingbar (psi)

(Q=5 l/min)= 03 Leakproof hex. socket screw

= 10 30-100 (450-1450) 13.5 (196) 100 (1450)

Common cavity, Size 10 = 20 100-240 (1450-3500) 31 (450) 200 (2900)

Note: Special settings available. Contact factory authorized representative for ordering code

04.11.59 X 85 Z 00 *

Page 247: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

239

1/2

Description

Flow is blocked from 1 to 2 until pressure increases to meet the selected valve setting, lifting the conical, pilot-stage poppet from its seat. This action exhausts oil above the main-stage piston (spool type), allowing it to shift and provide relief fl ow through 2 to tank. Pressure at 2 is additive to the relief setting of the valve.

Technical Features

Max. operating pressure port 1 (P)

bar (psi) 420 (6000)

Max. pressure admittedport 2 (T)

bar (psi) 350 (5000) for version 03210 (3000) for version 04

Flow range l/min. (gpm) 3–120 (1–32)

Max. internal leakage (*) cm3/min.(cu.in./min.)

200(12)

Fluid temperature range °C (°F) –30 to 100 (–22 to 212)

Installation torque Nm (ft-lbs) 41–47 (30–35)

Weight (**) kg (lbs) 0.21 (0.46)

Cavity CA-10A-2Nsee data sheet RE 18325-70

Line bodies See data sheet RE 18325-85

Seal kit (***) codematerial no.

RG10A2010530100R901111366

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 10 to 500 mm2/s (cSt)

Filtration Nominal value max. 10μm (NAS 8)ISO 4406 19/17/14

Installation No restrictions

Other Technical Data See data sheet RE 18350-50

(*) Measured at 200 bar (2900 psi)(**) Standard version X=03 type(***) Only external seals for 10 valves

Performance

Relief, pilot operated spool type

Common cavity, Size 10

VSPN-10A 04.12.08 - X - 85 - Z

RA 18318-08/10.11

Page 248: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics 041208X85Z RA 18318-08/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

240

2/2

Type Material number 041208038510000 R901097726

041208038520000 R901097722

041208038535000 R901104103

041208048535000 R901104104

Type Material number

Dimensions

Ordering code

Leakproof hex. socket screw

04.12.08 X 85 Z 00 *

OPTIONTamper resistant capOrdering code 11.04.23.002Mat. no. R930000752

Handknob and locknut

Series 0/A to L unchanged performances and dimensions

Relief, pilot operated spool type Version and options standard

SPRINGS

Adjustments Adj. pressure rangebar (psi)

Pres. increasebar/turn(psi/turn)

Std. settingbar (psi)

Q=5 l/min.= 03 Leakproof hex. socket screw

= 04 Handknob and locknutfor

X=03

= 10 35-140 (500-2000) 48 (696) 100 (1450)

= 20 70-280 (1000-4000) 88 (1276) 200 (2900)

Common cavity, Size 10 = 35 140-420 (2000-6000) 140 (2030) 350 (5000)for

X=04 = 35 35-350 (500-5000) 68 (986) 350 (5000)

Note: Special settings available. Contact factory authorized representative for ordering code

Page 249: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

241

1/2

Description

Initially, fl ow passes freely from 2 to 1. When the pressure at 1 exceeds the pres-sure setting, the valve acts to restrict input fl ow at 2. This increases the pres-sure drop through the valve and maintains consistent pressure at 1. The spring chamber is drained at 3 to prevent a build-up of back-pressure against the spool. Additionally, if pressure at 1 rises above the pressure setting, fl ow is relieved to 3 until the setting is re-attained.

Technical Features

Max. operating pressure port 2 (P)

bar (psi) 350 (5000)210 (3000) for version Z=01

Max. pressure admittedport 1 (A)

bar (psi) 105 (1500)

Max. fl ow l/min. (gpm) 30 (8)

Max. internal leakage (*) cm3/min.(cu.in./min.)

50(3)

Fluid temperature range °C (°F) –30 to 100 (–22 to 212)

Installation torque Nm (ft-lbs) 41–47 (30–35)

Weight (**) kg (lbs) 0.26 (0.57)

Cavity CA-10A-3Nsee data sheet RE 18325-70

Line bodies See data sheet RE 18325-85

Seal kit (***) codematerial no.

RG10A3010520100R901111369

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 10 to 500 mm2/s (cSt)

Filtration Nominal value max. 10μm (NAS 8)ISO 4406 19/17/14

Installation No restrictions

Other Technical Data See data sheet RE 18350-50

(*) 1–3 to 80% of pressure setting(**) Standard version X=03 type(***) Only external seals for 10 valves

Performance

Pressure reducing and relieving,direct acting spool type

Common cavity, Size 10

VRPR-10A 04.95.04 - X - 85 - Z

RA 18318-53/10.11

Page 250: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics 049504X85Z RA 18318-53/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

242

2/2

Type Material number 04950403850100A R901104066

04950403850200A R901109740

04950403850400A R901102333

04950403850800A R901109742

049504048501000 R901109743

Type Material number 04950404850200A R901109744

04950404850400A R901109745

04950404850800A R901109747

Dimensions

Ordering code

Leakproof hex. socket screw

04.95.04 X 85 Z 00 *

Handknob and locknut

Series 0/A to L unchanged performances and dimensions

Pressure reducing and relieving,direct acting spool type Version and options standard

SPRINGS

Adjustments Adj. pressure rangebar (psi)

Pres. increasebar/turn(psi/turn)

Std. settingbar (psi)

(reduc. mode)= 03 Leakproof hex. socket screw

= 04 Handknob and locknut = 01 2-14 (30-200) 2 (29) 8-10 (115-145)

= 02 2-25 (30-350) 3 (44) 7-10 (100-145)

Common cavity, Size 10 = 04 10-50 (145-725) 7 (102) 35-40 (500-580)

= 08 28-80 (400-1160) 14 (203) 45-50 (650-725)

Note: Special settings available. Contact factory authorized representative for ordering code

OPTIONTamper resistant capordering code 11.04.23.004Mat. no. R930001411

Page 251: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

243

1/2

Description

Initially, fl ow passes freely from 2 to 1. When the pressure at 1 exceeds the pres-sure setting, the conical poppet in the upper, pilot stage is lifted from its seat. This allows the main-stage piston to shift, restricting input fl ow at 2. This increases the pressure drop through the valve and maintains consistent pressure at 1. The spring chamber is drained at 3 to prevent a build-up of back-pressure against the spool. Additionally, if pressure at 1 rises above the pressure setting, fl ow is relieved to 3 until the setting is re-attained.

Technical Features

Max. operating pressure port 2 (P)

bar (psi) 350 (5000)

Max. pressure admittedport 1 (A)

bar (psi) 280 (4000)

Max. fl ow l/min. (gpm) 60 (16)

Standard internal pilotorifi ce diameter

mm 0.6

Fluid temperature range °C (°F) –30 to 100 (–22 to 212)

Installation torque Nm (ft-lbs) 41–47 (30–35)

Weight (*) kg (lbs) 0.2 (0.44)

Cavity CA-10A-3Nsee data sheet RE 18325-70

Line bodies See data sheet RE 18325-85

Seal kit (**) codematerial no.

RG10A3010520100R901111369

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 10 to 500 mm2/s (cSt)

Filtration Nominal value max. 10μm (NAS 8)ISO 4406 19/17/14

Installation No restrictions

Other Technical Data See data sheet RE 18350-50

(*) Standard version X=03 type(**) Only external seals for 10 valves

Performance

Pressure reducing and relieving,pilot operated spool type

Common cavity, Size 10

VRPX-10A 04.93.07 - X - 85 - Z

RA 18318-56/10.11

Page 252: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics 049307X85Z RA 18318-56/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

244

2/2

OPTIONTamper resistant capordering code 11.04.23.002Mat. no. R930000752

Type Material number 049307038510000 R901104118

049307038520000 R901106468

049307048535000 R930005596

Type Material number

Dimensions

Ordering code

Leakproof hex. socket screwHandknob and locknut

04.93.07 X 85 Z 00 *

Series 0/A to L unchanged performances and dimensions

Pressure reducing and relieving,pilot operated spool type

Version and options standard

SPRINGS

Adjustments Adj. pressure rangebar (psi)

Pres. increasebar/turn(psi/turn)

Std. settingbar (psi)

Q=5 l/min.= 03 Leakproof hex.socket screw

= 04 Handknob and locknut forX=03

= 10 35-140 (500-2000) 48 (696) 100 (1450)

= 20 70-280 (1000-4000) 88 (1276) 200 (2900)

Common cavity, Size 10for

X=04 = 35 35-350 (500-5000) 68 (986) 350 (5000)

Note: Special settings available. Contact factory authorized representative for ordering code

Page 253: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

245

1/2

Description

When pressure at 1 rises above the spring bias pressure, the poppet is lifted and fl ow allowed from 1 to 2. The valve is closed (checked) from 2 to 1. Precision machining and hardening processes allow virtually leak-free performance in the checked condition.

Technical Features

Max. operating pressure bar (psi) 350 (5000)

Max. fl ow l/min. (gpm) 80 (21)

Max. internal leakage drops/min. 5

Fluid temperature range °C (°F) –30 to 100 (–22 to 212)

Installation torque Nm (ft-lbs) 41–47 (30–35)

Weight (*) kg (lbs) 0.15 (0.33)

Cavity CA-10A-2Nsee data sheet RE 18325-70

Line bodies See data sheet RE 18325-85

Seal kit (**) codematerial no.

RG10A2010520100R901111363

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 15 to 800 mm2/s (cSt)

Filtration Nominal value max. 10μm (NAS 8)ISO 4406 19/17/14

Installation No restrictions

Other Technical Data See data sheet RE 18350-50

(*) Only external seals for 10 valves

Performance

Check, poppet type

Common cavity, Size 10

VUCN-10A 04.31.23.00.85 - Z

RA 18318-90/10.11

Page 254: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics 0431230085Z RA 18318-90/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

246

2/2

Type Material number 043123008500000 R901106596

043123008501000 R930005884

043123008505000 R901106601

043123008509000 R930000962

04312300851500A R901106602

Type Material number

Dimensions

Ordering code

Check, poppet type

Common cavity, Size 10

Series 0/A to L unchanged performances and dimensions

Version and options standard

SPRINGSCracking pressure

bar (psi)

= 00 0.5 (7.25)

= 01 1.4 (20)

= 05 5 (75)

= 09 9 (131)

= 15 15 (220)

04.31.23.00 85 Z 00 *

Page 255: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

247

1/2

Description

With fl ow from 2 to 1, the valve provides a fully adjustable orifi ce restriction. Free fl ow is permitted from 1 to 2, regardless of valve adjustment, by when pressure overcomes the spring bias of the valve’s check function.

Technical Features

Max. operating pressure bar (psi) 350 (5000)

Max. fl ow l/min. (gpm) 80 (21)

Max. internal leakage (*) drops/min. 15 closed

Fluid temperature range °C (°F) –30 to 100 (–22 to 212)

Installation torque Nm (ft-lbs) 41–47 (30–35)

Weight kg (lbs) 0.2 (0.44)

Cavity CA-10A-2Nsee data sheet RE 18325-70

Line bodies See data sheet RE 18325-85

Seal kit (**) codematerial no.

RG10A2010520100R901111363

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 5 to 800 mm2/s (cSt)

Filtration Nominal value max. 10μm (NAS 8)ISO 4406 19/17/14

Installation No restrictions

Other Technical Data See data sheet RE 18350-50

(*) Measured at 200 bar (2900 psi)(**) Only external seals for 10 valves

Performance

Needle restrictor,free reverse flow

Common cavity, Size 10

STVU-10A 04.01.05 - X - 85.00

RA 18321-11/10.11

Page 256: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics 040105X8500 RA 18321-11/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

248

2/2

Type Material number 040105038500000 R930005606

040105048500000 R930005607

Type Material number

Dimensions

Ordering code

Needle restrictor, free reverse flow

Adjustments

= 03 Leakproof hex. socket screw

= 04 Handknob and locknut

Common cavity, Size 10

Series 0/A to L unchanged performances and dimensions

Version and options standard

Leakproof hex. socket screw

Handknob and locknut

04.01.05 X 85 00 00 *

Page 257: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

249

1/2

Description

A constant fl ow rate, regardless of system pressures, is established from 1 to 3 while a minimum pressure differential of 14 bar (200 psi) exists between the two ports. Input fl ow supplied to 1 in excess of the regulated output at 3 is by-passed to 2. The valve cannot be adjusted for variable fl ow output. Flow from 3 to 1 is limited by the diameter of the selected control orifi ce and is not pressure compen-sated. Flow from 2 to 1 is not permitted.

Technical Features

Pressure min–max bar (psi) 14–350 (200–5000)

Max. inlet fl ow l/min. (gpm) 130 (34)

Flow range l/min (gpm) See “Regulated fl ow range” table

Fluid temperature range °C (°F) –30 to 100 (–22 to 212)

Installation torque Nm (ft-lbs) 81–95 (60–70)

Weight kg (lbs) 0.26 (0.57)

Cavity CA-12A-3Nsee data sheet RE 18325-70

Line bodies See data sheet RE 18325-85

Seal kit (*) codematerial no.

RG12A3010520100R930000941

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 10 to 500 mm2/s (cSt)

Filtration Nominal value max. 10μm (NAS 8)ISO 4406 19/17/14

Installation No restrictions

Other Technical Data See data sheet RE 18350-50

(*) Only external seals for 10 valves

Performance

Flow control, 3-way pressure compensated, combination type fixed settingCommon cavity, Size 12

VRFC-12A-TF 04.04.03.00.57 - Z

RA 18321-19/10.11

Page 258: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics 0404030057Z RA 18321-19/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

250

2/2

Type Material number 040403005715000 R930000070040403005720000 R930000071040403005723000 R930000072040403005726000 R930000073040403005729000 R930000074040403005737000 R930000075

Type Material number 040403005741000 R930000076040403005745000 R930000077040403005750000 R930000078040403005758000 R930000079040403005763000 R930000080

Dimensions

Ordering code

Flow control, 3-way pressure compensated combination type fixed setting

Common cavity, Size 12

Series 0/A to L unchanged performances and dimensions

Version and options standard

Regulated flow rangel/min. (gpm) ±10%

= 15 15 (4)= 20 20 (5)= 23 23 (6)= 26 26 (7)= 29 29 (8)= 37 37 (10)= 41 41 (11)= 45 45 (12)= 50 50 (13)= 58 58 (15)= 63 63 (17)

04.04.03.00 57 Z 00 *

Page 259: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

251

1/2

Description

A constant fl ow rate, regardless of system pressures, is established from 1 to 3 while a minimum pressure differential of 14 bar (200 psi) exists between the two ports. Input fl ow supplied to 1 in excess of the regulated output at 3 is by-passed to 2. Output fl ow can be varied from closed to the nominal maximum rating for the valve. Flow from 2 to 1 is not permitted.

Technical Features

Pressure min–max bar (psi) 14–350 (200–5000)

Max. inlet fl ow l/min. (gpm) 120 (32)

Flow range l/min (gpm) See “Regulated fl ow range” table

Fluid temperature range °C (°F) –30 to 100 (–22 to 212)

Installation torque Nm (ft-lbs) 81–95 (60–70)

Weight (*) kg (lbs) 0.3 (0.66)

Cavity CA-12A-3Nsee data sheet RE 18325-70

Line bodies See data sheet RE 18325-85

Seal kit (**) codematerial no.

RG12A3010530100R930001668

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 10 to 500 mm2/s (cSt)

Filtration Nominal value max. 10μm (NAS 8)ISO 4406 19/17/14

Installation No restrictions

Other Technical Data See data sheet RE 18350-50

(*) Standard version X=03 type(**) Only external seals for 10 valves

Performance

Flow control, 3-way pressure compensated, combination type fully adjustableCommon cavity, Size 12

VRFD-12A 04.04.04 - X - 57 - Z

RA 18321-21/10.11

Page 260: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Type Material number 040404035750000 R930006092

040404045750000 R930006093

Type Material number

Dimensions

Ordering code

Flow control, 3-way pressure compensated, combination type fully adjustable

Adjustments

= 03 Leakproof hex. socket screw

= 04 Handknob and locknut

Common cavity, Size 12

Series 0/A to L unchanged performances and dimensions

Version and options standard

Regulated flow rangel/min. (gpm)

= 50 2-50 (0.6-13.21)

04.04.04 X 57 Z 00 *

Bosch Rexroth Corp. | Hydraulics 040404X57Z RA 18321-21/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

252

2/2

Leakproof hex. socket screw

Handknob and locknut

Page 261: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

253

1/2

Description

When pressure at 1 rises above the selected spring bias pressure against the spool, the valve shifts to allow fl ow from 1 to 2. Pilot pressure at 3 is additive to the spring bias pressure. The valve may be used in switching or compensation type applications.

Technical Features

Max. operating pressure bar (psi) 350 (5000)

Max. inlet fl ow l/min. (gpm) 60 (16)

Max. internal leakage (*) cm3/min.(cu.in./min.)

50(3)

Fluid temperature range °C (°F) –30 to 100 (–22 to 212)

Installation torque Nm (ft-lbs) 41–47 (30–35)

Weight (**) kg (lbs) 0.12 (0.27)

Cavity CA-10A-3Csee data sheet RE 18325-70

Line bodies See data sheet RE 18325-85

Seal kit (***) codematerial no.

RG10A9010520100R901111367

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 10 to 500 mm2/s (cSt)

Filtration Nominal value max. 10μm (NAS 8)ISO 4406 19/17/14

Installation No restrictions

Other Technical Data See data sheet RE 18350-50

(*) Measured at 200 bar (2900 psi)(**) Standard version X=00 type(***) Only external seals for 10 valves

Performance

Logic element, flow and pressurecontrol with external pilot

Common cavity, Size 10

VLST-10A 04.84.01 - X - 85 - Z

RA 18321-60/10.11

Page 262: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics 048401X85Z RA 18321-60/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

254

2/2

Type Material number 048401008504000 R901106800

048401008508000 R901106801

048401008514000 R930000190

048401008517000 R930000095

048401038500000 R901104079

Type Material number

Dimensions

Ordering code

Logic element, flow and pressure control with external pilot

Adjustments

= 00 Fixed setting

= 03 Leakproof hex. socket screw

Common cavity, Size 10

Series 0/A to L unchanged performances and dimensions

Version and options standard

SPRINGS

Standard settingbar (psi)

Pres. increasebar/turn (psi/turn)

Bias springbar (psi)

forX=00

= 04 — — 4 (60) ±20%= 08 — — 8 (115) ±15%= 14 — — 14 (200) ±15%= 17 — — 17 (250) ±15%

forX=03 = 00 4 (60) 1 (15) 2-8 (30-115)

Note: Special settings available. Contact factory authorized representative for ordering code

04.84.01 X 85 Z 00 *

Fixed settingZ=04 and Z=08versions

Fixed settingZ=14 version

Fixed settingZ=17 version

Leakproof hex. socket screw

Page 263: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

255

1/2

Description

When pressure at 2 rises above the spring bias pressure, the check seat is pushed away from the piston and fl ow is allowed from 2 to 1. When load pressure at 1 rises above the pressure setting (turn counterclockwise to increase setting – turn clockwise to decrease setting), the direct-acting, relief function is activated and fl ow is relieved from 1 to 2. With pilot pressure at 3, the pressure setting is reduced in proportion to the stated ratio of the valve, until fully open with free-fl ow from 1 to 2. The spring chamber is drained to 2, and any back-pressure at 2 is additive to the pressure setting in all functions.

Technical Features

Max. operating pressure bar (psi) 280 (4000)

Max. fl ow l/min. (gpm) 30 (8)

Max. internal leakage (*) drops/min 15

Fluid temperature range °C (°F) –30 to 100 (–22 to 212)

Installation torque Nm (ft-lbs) 40–50 (30–37)

Weight kg (lbs) 0.18 (0.4)

Cavity SUN T-11A

Seal kit (**) codematerial no.

RG08U9020110100R901193388

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 10 to 500 mm2/s (cSt)

Filtration Nominal value max. 10μm (NAS 8)ISO 4406 19/17/14

Installation No restrictions

Other Technical Data See data sheet RE 18350-50

Pressure setting: at least 1.3 times the load induced pressure.(*) At 70% of pressure setting(**) Only external seals for 10 valves

Performance

Counterbalance, standard guidedpoppet type, counterclockwiseadjustmentSUN cavity interchange, T-11A

VBSN-08UU-RS 04.52.42 - X - 20 - Z

RA 18320-16/10.11

Page 264: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics 045242X20Z RA 18320-16/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

256

2/2

Type Material number 045242102020000 R930006107

045242372020000 R930006108

Type Material number

Dimensions

Ordering code

Counterbalance, standard guided poppettype, counterclockwise adjustment

Pilot ratio

= 10 4:1

= 37 9:1

SUN cavity interchange, SUN T-11A

Series 0/A to L unchanged performances and dimensions

Version and options standard

SPRINGS

Standard settingbar (psi)

Pres. increasebar/turn (psi/turn)

Cracking pressurebar (psi)

= 20 70-280 (1000-4000) 124 (1798) 210 (3000)

Note: Special settings available. Contact factory authorized representative for ordering code

04.52.42 X 20 Z 00 *

Turn adjustment clockwise to decrease setting and release load

Leakproof hex. socket screw

Page 265: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

257

1/2

Description

When pressure at 2 rises above the spring bias pressure, the check seat is pushed away from the piston and fl ow is allowed from 2 to 1. When load pressure at 1 rises above the pressure setting (turn counterclockwise to increase setting - turn clockwise to decrease setting), the direct-acting, differential area relief function is activated and fl ow is relieved from 1 to 2. With pilot pressure at 3, the pressure setting is reduced in proportion to the stated ratio of the valve, until fully open with free-fl ow from 1 to 2. Any back-pressure at 2 is additive to the pressure setting in all functions.

Technical Features

Max. operating pressure bar (psi) 350 (5000)

Max. fl ow l/min. (gpm) 60 (16)

Max. internal leakage (*) drops/min 15

Fluid temperature range °C (°F) –30 to 100 (–22 to 212)

Installation torque Nm (ft-lbs) 40–50 (30–37)

Weight kg (lbs) 0.19 (0.42)

Cavity SUN T-11A

Seal kit (**) codematerial no.

RG08U9020110100R901193388

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 10 to 500 mm2/s (cSt)

Filtration Nominal value max. 10μm (NAS 8)ISO 4406 19/17/14

Installation No restrictions

Other Technical Data See data sheet RE 18350-50

Pressure setting: at least 1.3 times the load induced pressure.(*) At 70% of pressure setting(**) Only external seals for 10 valves

Performance

Counterbalance, standard poppet type, differential area,counterclockwise adjustmentSUN cavity interchange, T-11A

VBSN-08U-RS 04.52.43 - X - 20 - Z

RA 18320-17/10.11

Page 266: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics 045243X20Z RA 18320-17/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

258

2/2

Type Material number 045243032010000 R930006109

045243032020000 R930006110

045243032035000 R930006111

045243102020000 R930006112

045243102035000 R930006113

Type Material number 045243312020000 R930006114

045243312035000 R930006115

Dimensions

Ordering code

Counterbalance, standard poppet type, differential area, counterclockwise adjustment

Pilot ratio

= 03 3:1 standard version

= 10 8:1 standard version

= 31 1.5:1 with bleed-through pilot

SUN cavity interchange, SUN T-11A

04.52.43 X 20 Z 00 *

Turn adjustment clockwise to decrease setting and release load

Leakproof hex. socket screw

Series 0/A to L unchanged performances and dimensions

Version and options standard

SPRINGS

Standard settingbar (psi)

Pres. increasebar/turn (psi/turn)

Cracking pressurebar (psi)

forX=03

= 10 35-105 (500-1500) 26 (377) 70 (1000)

= 20 70-210 (1000-3000) 106 (1537) 200 (2900)

= 35 140-350 (2000-5000) 165 (2393) 350 (5000)

forX=10

= 20 70-210 (1000-3000) 40 (580) 200 (2900)

= 35 140-350 (2000-5000) 70 (1015) 350 (5000)

forX=31

= 20 70-210 (1000-3000) 106 (1537) 200 (2900)

= 35 140-350 (2000-5000) 165 (2393) 350 (5000)

Note: Special settings available. Contact factory authorized representative for ordering code

Page 267: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

259

1/2

Description

When pressure at 2 rises above the spring bias pressure, the check seat is pushed away from the piston and fl ow is allowed from 2 to 1. When load pressure at 1 rises above the pressure setting (turn counterclockwise to increase setting - turn clockwise to decrease setting), the direct-acting, differential area relief function is activated and fl ow is relieved from 1 to 2. With pilot pressure at 3, the pressure setting is reduced in proportion to the stated ratio of the valve, until fully open with free-fl ow from 1 to 2. The valve applies a balanced piston design allowing relief operation at the valve setting independent of back-pressure at 2. However, the piloted opening of the valve remains subject to additive pressure at port 2.

Technical Features

Max. operating pressure bar (psi) 350 (5000)

Max. fl ow l/min. (gpm) 60 (16)

Max. internal leakage (*) drops/min 15

Fluid temperature range °C (°F) –30 to 100 (–22 to 212)

Installation torque Nm (ft-lbs) 40–50 (30–37)

Weight kg (lbs) 0.19 (0.42)

Cavity SUN T-11A

Seal kit (**) codematerial no.

RG08U9020110100R901193388

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 10 to 500 mm2/s (cSt)

Filtration Nominal value max. 10μm (NAS 8)ISO 4406 19/17/14

Installation No restrictions

Other Technical Data See data sheet RE 18350-50

Pressure setting: at least 1.3 times the load induced pressure.(*) At 70% of pressure setting(**) Only external seals for 10 valves

Performance

Counterbalance, relief compensated poppet type, differential area,counterclockwise adjustmentSUN cavity interchange, T-11A

VBSP-08U-RS 04.54.15 - X - 20 - Z

RA 18320-20/10.11

Page 268: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics 045415X20Z RA 18320-20/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

260

2/2

Type Material number 045415032020000 R930006122

045415032035000 R930006123

Type Material number

Dimensions

Ordering code

Counterbalance, relief compensated poppet type differential area, counterclockwise adjustment

Pilot ratio

= 03 3:1

SUN cavity interchange, SUN T-11A

04.54.15 X 20 Z 00 *

Turn adjustment clockwise to decrease setting and release load

Leakproof hex. socket screw

Series 0/A to L unchanged performances and dimensions

Version and options standard

SPRINGS

Adj. pressure rangebar (psi)

Pressure increasebar/turn (psi/turn)

Cracking pressurebar (psi)

= 20 70-210 (1000-3000) 106 (1537) 200 (2900)

= 35 140-350 (2000-5000) 165 (2393) 350 (5000)

Note: Special settings available. Contact factory authorized representative for ordering code

Page 269: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

261

1/2

Description

When pressure at 2 rises above the spring bias pressure, the check seat is pushed away from the piston and fl ow is allowed from 2 to 1. When load pressure at 1 rises above the pressure setting (turn counterclockwise to increase setting - turn clockwise to decrease setting), the direct-acting, relief function is activated and fl ow is relieved from 1 to 2. With pilot pressure at 3, the pressure setting is reduced in proportion to the stated ratio of the valve, until fully open with free-fl ow from 1 to 2. The spring chamber is vented to atmosphere allowing operation of all functions independent of back-pressure at 2.

Technical Features

Max. operating pressure bar (psi) 350 (5000)

Max. fl ow l/min. (gpm) 60 (16)

Max. internal leakage (*) drops/min 15

Fluid temperature range °C (°F) –30 to 100 (–22 to 212)

Installation torque Nm (ft-lbs) 40–50 (30–37)

Weight kg (lbs) 0.19 (0.42)

Cavity SUN T-11A

Seal kit (**) codematerial no.

RG08U9020110100R901193388

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 10 to 500 mm2/s (cSt)

Filtration Nominal value max. 10μm (NAS 8)ISO 4406 19/17/14

Installation No restrictions

Other Technical Data See data sheet RE 18350-50

Pressure setting: at least 1.3 times the load induced pressure.(*) At 70% of pressure setting(**) Only external seals for 10 valves

Performance

Counterbalance, vented guided poppet type,counterclockwise adjustmentSUN cavity interchange, T-11A

VBST-08U-RS 04.59.29 - X - 20 - Z

RA 18320-23/10.11

Page 270: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics 045929X20Z RA 18320-23/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

262

2/2

Type Material number 045929032015000 R930006129

045929032020000 R930006130

Type Material number

Dimensions

Ordering code

Counterbalance, vented guided poppet type, counterclockwise adjustment

Pilot ratio

= 03 3:1

SUN cavity interchange, SUN T-11A

04.59.29 X 20 Z 00 *

Turn adjustment clockwise to decrease setting and release load

Leakproof hex. socket screw

Series 0/A to L unchanged performances and dimensions

Version and options standard

SPRINGS

Standard settingbar (psi)

Pressure increasebar/turn (psi/turn)

Cracking pressurebar (psi)

= 10 25-175 (350-2500) 70 (1015) 175 (2500)

= 20 70-280 (1000-4000) 109 (1581) 280 (4000)

Note: Special settings available. Contact factory authorized representative for ordering code

Page 271: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

263

1/4

Solenoid operated valves pilot operated poppet type 2-way normally closedCommon cavity, Size 08

VEI-8A-06-NC OD.15 - X - Y - Z - S

RA 18323-02/10.11

version 1 version 2 version 3 version 4

GeneralWeight kg (lbs) 0.16 (0.35)

Installation orientation Optional

Ambient temperature range °C (°F) –30 to 60 (–22 to 140)

HydraulicMax. operating pressure bar (psi) 350 (5000)

Max. proof pressure bar (psi) 420 (6000)

Flow range l/min. (gpm) 0.5–40 (0.1–11)

Fatigue cycle life cycles 1 million cycles at 350 bar

Max. internal leakage drops/min. 20

Fluid temperature range °C (°F) –20 to 80 (–4 to 176)

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 20 to 380 mm2/s (cSt)

Installation torque Nm (ft-lbs) 39–51 (29–38)

Filtration Nominal value max. 10μm (NAS 8) ISO 4406 19/17/14

Cavity CA-08A-2N (version 4: 019-E)

Line bodies See data sheet RE 18325-85

Seal kit version 1 codematerial no.

RG08A2010520100R901101437

Seal kit version 2-3

codematerial no.

RG08A2010530100R901101544

Seal kit version 4 codematerial no.

RG19E201053010R934003561

Seal kit coil codematerial no.

RG12A1PNBR7000R934003591

Other technical data See data sheet RE 18350-50

ElectricalType of voltage DC voltage

Coil type S8-356 see RE 18325-90

Supply voltage See data sheet RE 18325-90

Nominal voltage ± 10%

Power consumption W 20

Duty cycle coil % See performance graphs

Type of protection See data sheet RE 18325-90

Note: Coils must be ordered separately.

Page 272: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics OD15XYZS RA 18323-02/10.11

264

2/4

Dimensions

Knob style manual override typeStandard type

Standard type

Standard type

Version 1: Solenoid operated valve, poppet 2-way normally closed

Version 4: Solenoid operated valve, poppet 2-way normally closed

Version 2: Solenoid operated valve, poppet 2-way normally closedVersion 3: Solenoid operated valve, poppet 2-way double lock normally closed

Version 1 - 2 - 3 - 4

Page 273: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18323-02/10.11 OD15XYZS Hydraulics | Bosch Rexroth Corp.

265

3/4

Performance graphs

Version 1 – Version 2

Version 4

Version 3

Standard

Standard

Standard

Extra spring

Extra spring

Page 274: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics OD15XYZS RA 18323-02/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

266

4/4

Type Material number OD1501183AS000 R901091096

OD1501183DS000 R901091101

OD1503183AS000 R934000779

OD1503183AS800 R934003063

OD1503183DS000 R901091112

OD1503183DS800 R934003064

Type Material number OD1505183AS000 R901083058

OD1505183AS800 R934003080

OD1505183DS000 R901087979

OD1509183AS000 R901091150

OD1509183DS000 R901091151

OD1531183AS000 R901082015

Type Material number OD1531183AS800 R934000104

OD1531183DS000 R901091164

OD1511193AS000 R901091157

OD1511193DS000 R901091158

Ordering code

OD.15 X Y * *

Solenoid operated valves poppet type 2-waynormally closed

monodirectional type

= 01

bidirectional type

= 05

monodirectional type

= 09

bidirectional type

= 03

bidirectional type

= 31

monodirectional type

only with Y = 19

= 11

S0 = Tube not welded

S8 = Tube not welded with extra spring

for X = 05

for X = 03

for X = 31

3A =

standard type

3D =

knob style manual override

18 = Common cavity: CA-08A-2N

19 = Special cavity: 019-E only with X = 11

Page 275: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

267

1/4

Solenoid operated valves pilot operated poppet type 2-way normally openCommon cavity, Size 08

VEI-8A-06-NA OD.15 - X - Y - Z - S0

RA 18323-06/10.11

version 1 version 2 version 3 version 4

GeneralWeight kg (lbs) 0.12 (0.26)

Installation orientation Optional

Ambient temperature range °C (°F) –30 to 60 (–22 to 140)

HydraulicMax. operating pressure bar (psi) 350 (5000)

Max. proof pressure bar (psi) 420 (6000)

Flow range l/min. (gpm) 1.5–40 (0.4–11)

Fatigue cycle life cycles 1 million cycles at 350 bar

Max. internal leakage drops/min. 20

Fluid temperature range °C (°F) –20 to 80 (–4 to 176)

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 20 to 380 mm2/s (cSt)

Installation torque Nm (ft-lbs) 39–51 (29–38)

Filtration Nominal value max. 10μm (NAS 8) ISO 4406 19/17/14

Cavity CA-08A-2N / 019-E see RE 18325-75

Line bodies See data sheet RE 18325-85

Seal kit version 1 codematerial no.

RG08A2010520100R901101437

Seal kit version 2-3

codematerial no.

RG04A2010530100R901101544

Seal kit version 4 codematerial no.

RG19E201053010R934003561

Seal kit coil codematerial no.

RG12A1PNBR7000R934003591

Other technical data See data sheet RE 18350-50

ElectricalType of voltage DC voltage

Coil type S8-356 see RE 18325-90

Supply voltage See data sheet RE 18325-90

Nominal voltage ± 10%

Power consumption W 20

Duty cycle coil % See performance graphs

Type of protection See data sheet RE 18325-90

Note: Coils must be ordered separately.

Page 276: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics OD15XYZS0 RA 18323-06/10.11

268

2/4

Dimensions

Push style manual override

Push and twist style manual override

Standard type

Standard type

Standard type

Version 1: Solenoid operated valve, poppet 2-way normally open

Version 4: Solenoid operated valve, poppet 2-way normally open

Version 2: Solenoid operated valve, poppet 2-way normally openVersion 3: Solenoid operated valve, poppet 2-way double lock normally open

Version 1 - 2 - 3 - 4

Page 277: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18323-06/10.11 OD15XYZS0 Hydraulics | Bosch Rexroth Corp.

269

3/4

Performance graphs

Version 1 – Version 2

Standard

Version 4

Standard

Version 3

Standard

Page 278: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics OD15XYZS0 RA 18323-06/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

270

4/4

Type Material number OD1502181AS000 R901091102

OD1502181BS000 R901091105

OD1502181CS000 R901091106

OD1506181AS000 R901091130

OD1506181BS000 R901091131

OD1506181CS000 R901091132

Type Material number OD1504181AS000 R901091121

OD1504181BS000 R901091122

OD1504181CS000 R901091123

OD1510181AS000 R901091152

OD1510181BS000 R901091154

OD1510181CS000 R901091155

Type Material number OD1532181AS000 R901091171

OD1532181BS000 R901091173

OD1532181CS000 R901091174

OD1512191AS000 R901091159

OD1512191BS000 R901091161

OD1512191CS000 R901091162

Ordering code

OD.15 X Y * S0

Solenoid operated valves poppet type 2-waynormally open

monodirectional type

= 02

bidirectional type

= 06

monodirectional type

= 10

bidirectional type

= 04

bidirectional type

= 32

monodirectional type

only with Y = 19

= 12

Tube not welded

1A =

standard type

1B =

Push style manual override

1C =

Push and twist style manual override

18 = Common cavity: CA-08A-2N

19 = Special cavity: 019-E only with X = 12

Page 279: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

271

1/4

Solenoid operated valves pilot operated poppet type 2-way normally openCommon cavity, Size 10

VEI-8A-10-NA OD.15 - X - 36 - Y - S0

RA 18323-12/10.11

version 1 version 2 version 3

GeneralWeight kg (lbs) 0.16 (0.35)

Installation orientation Optional

Ambient temperature range °C (°F) –30 to 60 (–22 to 140)

HydraulicMax. operating pressure bar (psi) 350 (5000)

Max. proof pressure bar (psi) 420 (6000)

Flow range l/min. (gpm) 2–70 (0.5–18)

Fatigue cycle life cycles 1 million cycles at 350 bar

Max. internal leakage drops/min. 20

Fluid temperature range °C (°F) –20 to 80 (–4 to 176)

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 20 to 380 mm2/s (cSt)

Installation torque Nm (ft-lbs) 44–56 (33–42)

Filtration Nominal value max. 10μm (NAS 8) ISO 4406 19/17/14

Cavity CA-10A-2N see RE 18325-75

Line bodies See data sheet RE 18325-85

Seal kit version 1 codematerial no.

RG10A2010520100R901111363

Seal kit version 2-3

codematerial no.

RG10A2010530100R901111366

Seal kit coil codematerial no.

RG12A1PNBR7010R934003958

Other technical data See data sheet RE 18350-50

ElectricalType of voltage DC voltage

Coil type S8-356 see RE 18325-90

Supply voltage See data sheet RE 18325-90

Nominal voltage ± 10%

Power consumption W 20

Duty cycle coil % See performance graphs

Type of protection See data sheet RE 18325-90

Note: Coils must be ordered separately.

Page 280: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics OD15X36YS0 RA 18323-12/10.11

272

2/4

Dimensions

Push style manual override

Push and twist style manual override

Standard type

Standard type

Version 1: Solenoid operated valve, poppet 2-way normally open

Version 2: Solenoid operated valve, poppet 2-way normally openVersion 3: Solenoid operated valve, poppet 2-way double lock normally open

Version 1 - 2 - 3

Page 281: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18323-12/10.11 OD15X36YS0 Hydraulics | Bosch Rexroth Corp.

273

3/4

Performance graphs

Version 1 – Version 2

Standard

Version 3

Standard

Page 282: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics OD15X36YS0 RA 18323-12/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

274

4/4

Type Material number OD1504361AS000 R901091124

OD1504361BS000 R901091125

OD1504361CS000 R901091126

OD1506361AS000 R901080489

OD1506361BS000 R901091136

OD1506361CS000 R901091137

Type Material number OD1532361AS000 R901091175

OD1532361BS000 R901091176

OD1532361CS000 R901091178

Ordering code

OD.15 * 36 * S0

Solenoid operated valves poppet type 2-waynormally open

monodirectional type

= 06

bidirectional type

= 04

monodirectional type with filter

= 32

Tube not welded

1A =

standard type

1B =

Push style manual override

1C =

Push and twist style manual override

Common cavity: CA-10A-2N

Page 283: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

275

1/4

Solenoid operated valves pilot operated poppet type 2-way normally closedCommon cavity, Size 10

VEI-8A-10-NC OD.15 - X - 36 - Y - Z

RA 18323-11/10.11

version 1 version 2 version 3

GeneralWeight kg (lbs) 0.16 (0.35)

Installation orientation Optional

Ambient temperature range °C (°F) –30 to 60 (–22 to 140)

HydraulicMax. operating pressure bar (psi) 350 (5000)

Max. proof pressure bar (psi) 420 (6000)

Flow range l/min. (gpm) 2–70 (0.5–18)

Fatigue cycle life cycles 1 million cycles at 350 bar

Max. internal leakage drops/min. 20

Fluid temperature range °C (°F) –20 to 80 (–4 to 176)

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 20 to 380 mm2/s (cSt)

Installation torque Nm (ft-lbs) 44–56 (33–42)

Filtration Nominal value max. 10μm (NAS 8) ISO 4406 19/17/14

Cavity CA-10A-2N see RE 18325-75

Line bodies See data sheet RE 18325-85

Seal kit version 1 codematerial no.

RG10A2010520100R901111363

Seal kit version 2-3

codematerial no.

RG10A2010530100R901111366

Seal kit coil codematerial no.

RG12A1PNBR7010R934003958

Other technical data See data sheet RE 18350-50

ElectricalType of voltage DC voltage

Coil type S8-356 see RE 18325-90

Supply voltage See data sheet RE 18325-90

Nominal voltage ± 10%

Power consumption W 20

Duty cycle coil % See performance graphs

Type of protection See data sheet RE 18325-90

Note: Coils must be ordered separately.

Page 284: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics OD15X36YZ RA 18323-11/10.11

276

2/4

Dimensions

Knob style manual override

Standard type

Standard type

Version 1: Solenoid operated valve, poppet 2-way normally closed

Version 2: Solenoid operated valve, poppet 2-way normally closedVersion 3: Solenoid operated valve, poppet 2-way double lock normally closed

Version 1 - 2 - 3

Page 285: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18323-11/10.11 OD15X36YZ Hydraulics | Bosch Rexroth Corp.

277

3/4

Performance graphs

Version 1 – Version 2

Version 3

Standard

Standard

Extra spring

Extra spring

Page 286: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics OD15X36YZ RA 18323-11/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

278

4/4

Type Material number OD1503363AS000 R901091113

OD1503363AS800 R901091114

OD1503363DS800 R901109956

OD1505363AS000 R901090947

OD1505363AS800 R901090945

OD1505363DS000 R901080482

Type Material number OD1505363DS800 R901109969

OD1531363AS000 R901091166

OD1531363AS800 R901109984

OD1531363DS000 R901091167

OD1531363DS800 R901109985

Ordering code

OD.15 X 36 * *

Solenoid operated valves poppet type 2-waynormally closed

bidirectional type

= 05

bidirectional type

= 03

double lock

= 31

S0 = Tube not welded

S8 = Tube not welded with extra spring

for X = 05

for X = 03

for X = 31

3A =

standard type

3D =

knob style manual override

Common cavity: CA-10A-2N

Page 287: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

(*) Measure at 210 bar (3000 psi). Oil at 46 cSt.

279

1/4

Proportional valves notcompensated flow regulator

Common cavity, Size 10

VEP-5A-2Q-09 OD.92 - X - 77 - Y - Z

RA 18323-63/10.11

Inlet

Outlet

Drain

Version 03 Version 05

Version 03: Port 1 not used.

GeneralWeight kg (lbs) 0.32 (0.71)

Installation orientation Optional

Ambient temperature range °C (°F) –30 to 60 (–22 to 140)

HydraulicMax. operating pressure bar (psi) 210 (3000)

Flow range l/min. (gpm) see fl ow diagram

Max. internal leakage (*) cm3/min.(cu.in/min.) 100 (6)

Fluid temperature range °C (°F) –20 to 80 (–4 to 176)

Fluids Mineral-based or synthetics with lubricating properties at viscosities of 15 to 380 mm2/s (cSt)

Installation torque Nm (ft-lbs) 44–56 (33–41)

Filtration Nominal value max. 10μm (NAS 8) ISO 4406 19/17/14

Cavity CA-10A-3N see RE 18325-70

Line bodies See data sheet RE 18325-85

Seal kit codematerial no.

RG10A3010520100R901111369

Seal kit coil codematerial no.

RG19A1PNBR7010R934003964

Other technical data See data sheet RE 18325-90

ElectricalType of voltage DC voltage

Coil type S5

Supply voltage 12 DC

Nominal voltage ± 10%

Power consumption W 23

Duty cycle coil % 100

Type of protection See data sheet RE 18325-90

Note: Coils must be ordered separately.

Page 288: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics OD92X77YZ RA 18323-63/10.11

280

2/4

Dimensions

Proportional valves not compensated fl ow regulator

Version 03PORT NOT USED

Page 289: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18323-63/10.11 OD92X77YZ Hydraulics | Bosch Rexroth Corp.

281

3/4

Performance graphs

PMW Frequency: 120-150 Hz

Hysteresis: < 5%

Note: It is recommended to use coil 12 DC.

Z = 01

Z = 02

Z = 03

Page 290: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics OD92X77YZ RA 18323-63/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

282

4/4

Type Material number OD920377030100 R934001518

OD920377030200 R934001519

OD920377030300 R934001520

OD920377040100 R934001521

OD920377040200 R934003909

OD920377040300 R934001522

Type Material number OD920577030100 R934001524

OD920577030200 R934003130

OD920577030300 R934001525

OD920577040100 R934001526

OD920577040200 R901176252

OD920577040300 R93401528

Ordering code

OD.92 X 77 Y Z

Proportional valves not compensated flow regulator

= 03

= 05

Operating rangeRated fl ow max

l/min (gpm)I Min.

A (±10%)I Max.

A (±10%)= 01 20 (6) 0.9 2

= 02 30 (8) 0.8 2

= 03 40 (11) 0.8 2

03 =

standard type

04 =

knob style manual override

Common cavity: CA-10A-3N

Page 291: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

283

1/4

Coils

RA 18325-90/10.11

Description Page

Coil S8-356 – CLASS H – 20 W 1-2

Coil S5 – CLASS H – 20 W 3

Summary

Coil S8-356 – Class H – 20 W OD.02.17 - X - Y - Z

Technical DataWeight: 0.18 kg (0.40 lbs)Heat insulation Class H: 180°C (356°F)Ambient temperature range: –30/+60°C (–22/+140°F)Inlet voltage fl uctuations must not exceed ±10% of nominal voltage to obtain correct operation and long life coils.

X Y Connections Circuit Voltage

01 30 DIN 43650 – ISO 4400 Standard DC-RAC07 30 AMP JUNIOR Standard DC0G 03 SINGLE LEAD Standard DC *14 30 DIN 43650 – ISO 4400 Bidirectional Diode DC15 30 AMP JUNIOR Bidirectional Diode DC0H 03 SINGLE LEAD Bidirectional Diode DC *

* Length 300mm (11.8 inches). Ext. diameter 6.3mm (0.25 inches). External and internal Shealth Silicone rubber.

Z

Voltage (V)

Resistance Ω (±7%)

Power (W)

Current (A)

ΔT °C (°F)

Nominal Ta = 20–25 °C (68–77 °F)

Cold coil

Cold coil

Hot coil

1 hour energized at Ta = 20–25 °C

(68–77 °F)Nominal voltage

OB 12 DC 7.2 20 1.7 1.2105–110

(221–230)OG 14 DC 9.0 20 1.6 1.1OC 24 DC 28.2 20 0.9 0.6AC 26 DC 33.6 20 0.8 0.5OV 24 RAC 23.1 20 0.9 —

110–125(230–257)

OW 110 RAC 478.3 20 0.2 —OZ 220 RAC 1919.9 20 0.1 —

Page 292: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics Coils RA 18325-90/10.11

284

2/4

Coil S8-356 – Class H – 20 W (continued) OD.02.17 - X - Y - Z

Preferred types (readily available)

X Y Connections Circuit Voltage

20 30 DEUTSCH DT04-2P-L Standard DC20 3P DEUTSCH DT04-2P-V Standard DC30 3P AMP SUPERSEAL-V Standard DC22 30 DEUTSCH DT04-2P-L Bidirectional Diode DC22 3P DEUTSCH DT04-2P-V Bidirectional Diode DC32 3P AMP SUPERSEAL-V Bidirectional Diode DC

Z

Voltage (V)

Resistance Ω (±7%)

Power (W)

Current (A)

ΔT °C (°F)

Nominal Ta = 20–25 °C (68–77 °F)

Cold coil

Cold coil

Hot coil

1 hour energized at Ta = 20–25 °C

(68–77 °F)Nominal voltage

OB 12 DC 7.2 20 1.7 1.2105–110

(221–230)OC 24 DC 28.2 20 0.9 0.6AC 26 DC 33.6 20 0.8 0.5

These coils have passed the THERMAL SHOCK DUNK TEST

Type Material number OD02170130AC00 R901058832

OD02170130OB00 R901090821

OD02170130OC00 R901083065

OD02170130OG00 R901144215

OD02170130OV00 R901090820

OD02170130OW00 R901087981

OD02170130OZ00 R901085466

OD02170730AC00 R934000494

OD02170730OB00 R901094604

OD02170730OC00 R901094607

OD02170730OG00 R934000498

OD02170G03OB00 R901100773

OD02170G03OC00 R901100775

OD02171430OB00 R901131889

OD02171430OC00 R901121821

OD02171530AC00 R901133139

Type Material number OD02171530OB00 R901111032

OD02171530OC00 R901125292

OD02172030OB00 R901094609

OD02172030OC00 R901094611

OD0217203PAC00 R934000509

OD0217203POB00 R901110014

OD0217203POC00 R901110015

OD02172230OB00 R901130433

OD02172230OC00 R901130401

OD02172230OG00 R934003033

OD0217223POB00 R901120671

OD0217223POC00 R901114602

OD0217303PAC00 R934000516

OD0217303POB00 R901110016

OD0217323POB00 R934000519

Further types available by request.

Page 293: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 18325-90/10.11 Coils Hydraulics | Bosch Rexroth Corp.

285

3/4

Coil S5 – Class H – 20 W OD.02.09 - X - Y - Z - 01

Preferred types (readily available)

Type Material number OD02090130OB01 R901090827

OD02090130OC01 R901090828

OD0209203POB01 R901110011

Type Material number OD0209203POC01 R901110012

OD0209223POB01 R901090829

OD0209223POC01 R901110013

Further types available by request.

Technical DataWeight: 0.47 kg (1.04 lbs)Heat insulation Class H: 180°C (356°F)Ambient temperature range: –30/+70°C (–22/+158°F)Inlet voltage fl uctuations must not exceed ±10% of nominal voltage to obtain correct operation and long life coils.

X Y Connections Circuit Voltage

20 3P DEUTSCH DT-04-2P-V Standard DC

22 3P DEUTSCH DT-04-2P-V Bidirectional Diode DC

Z

Voltage (V)

Resistance Ω (±7%)

Power (W)

Current (A)

ΔT °C (°F)

Nominal Ta = 20–25 °C (68–77 °F)

Cold coil

Cold coil

Hot coil

1 hour energized at Ta = 20–25 °C

(68–77 °F)Nominal voltage

OB 12 DC 6.2 23 1.9 1.4 92–96(198–205)OC 24 DC 24.9 23 1.0 0.7

Page 294: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

Bosch Rexroth Corp. | Hydraulics Coils RA 18325-90/10.11

Bosch Rexroth Corp.Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

© This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties.

The data specifi ed above only serve to describe the product. Nostatements concerning a certain condition or suitability for a certainapplication can be derived from our information. The information givendoes not release the user from the obligation of own judgment andverifi cation. It must be remembered that our products are subject to anatural process of wear and aging.

286

4/4

Page 295: Compact Bankable Directional Valves · 2019. 7. 4. · P.O. check stacking modules EDM-PO SAE 8 210 (3000) 60 (15) 203 AB Cross-port relief stacking modules EDM-CR SAE 8 210 (3000)

RA 00159/04.13© Bosch Rexroth Corporation 2013 Printed in the United States

Bosch Rexroth CorporationBosch Rexroth Oil Control, N.A.Applications Center553 Telser RoadLake Zurich, IL 60047Telephone (847) 719-2950Facsimile (847) 719-2955www.boschrexroth-us.com

Bosch Rexroth CorporationBosch Rexroth Oil Control, N.A.2315 City Line RoadBethlehem, PA 18017-2131Telephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com