34
Department of Public Works and Environmental Services Huntington Levee Community Meeting October 26, 2016

Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Department of Public Works and Environmental Services

Huntington LeveeCommunity Meeting

October 26, 2016

Page 2: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 2

AgendaHuntington Levee

I. Project Background

II. Levee System Design

III. Construction

IV. Community Amenities

V. Flood Modeling Results

VI. Permitting

VII. Schedule

VIII. Environmental Design

IX. Community Outreach

X. Questions

Page 3: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 3

Project Background

• June 2006 -160 homes were flooded from a storm event

• 2009 – US Army Corps of Engineers (USACE) completed a study to evaluate flood damage reduction measures in the Huntington Community

• November 6, 2012 – Fairfax County voters approved stormwater bond referendum

• November 2013 – Phase I design completed

• January 2014 – Fairfax County and Huntington Community reached consensus on conceptual design features

Page 4: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 4

Project Background

• July 2014 – Hydraulic and Hydrologic Modelling for Cameron Run

• September 2014 – Schematic (30%) Design

• October 2014 - Value Engineering Workshop

• June 2015 – Design Development (60%) Design

• February 2016 – Construction Documents (100%) Design

• Spring 2016 – Technical review by County and Corps of Engineers

• July 2016 – CLOMR approved by FEMA

• August 2016 – Project advertised for bid to pre-qualified contractors

• September 2016 – Wetlands permitting approved by DEQ and Corps of Engineers

Page 5: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 5

Levee System Design

Levee System

Page 6: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 6

Levee System Design

Key Design Features

• Earthen Levee/I-Wall Combination

• Pump Station

• Stormwater Diversion

Page 7: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 7

Levee System Design

Rendering – Looking West

Levee I-WallOpen Channel

Ponding AreaCameron Run

Page 8: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 8

Levee System Design

Rendering – Looking East with Cross Section

Asphalt Trail

Open Channel with Drains

Ponding Area

Ponding Area

SlopeSlope

Slope

Sloped to Pump Station

Page 9: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 9

Levee System Design

Rendering – Looking East from Top of Levee Trail

Asphalt Trail

Concrete I-Wall

Ponding Area

Page 10: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 10

Levee System Design

Rendering – Looking Northeast Toward Pump Station

Note: Fence with gate to be constructed around Pump Station

Page 11: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 11

Levee System Design

Rendering – Cross Section of Pump Station

Page 12: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 12

Construction

Next Steps in Construction

Bids Opened

Bid Evaluation

County Approval of

Contract

Notice of Award

Notice to Proceed

October 6, 2016

October 2016

November 2016

December 2016

January 2017

Page 13: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 13

Construction

Key Activities during Construction

Notice to Proceed

Site Management

Plan

Contractor Mobilization

Substantial Completion

January 2017

January/ February

2017

January/ February

2017

February 2019

Page 14: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 14

Site Management Plan

• Submitted by contractor 30 days after NTP

• Approved by County

Included in Site Management Plan

• Phasing of Construction

• Control of Water

• Emergency Response

Construction

Page 15: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 15

Contractor Restrictions

• Construction activities limited to 7:00am to 7:00pm, Monday – Friday

• Weekend and holiday work to be approved by County

• Contractor parking prohibited in neighborhood

• Truck traffic through neighborhood restricted

• Noise per Fairfax County Noise Ordinance

Construction

Page 16: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 16

Construction

First Construction Activities

• Identification of Limits of Disturbance

• Safety Fencing

• Erosion and Sediment Control

• Construction of Access Road

Page 17: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 17

Construction

Construction ExtentsFor General Reference – Actual Extent determined by Contractor

Construction Safety Fence around Site Perimeter

Construction Access Road

Utility Work

Location of Pump Station

Page 18: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 18

Construction

Construction Access

• Route A: Primary Construction Access

• Route D: Secondary Access for Pump Station

• Routes B and C: Possible Tertiary Construction Access

Page 19: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 19

Community Amenities

Trails• Native Grasses in Ponding Area, Mowed 1-3 times per Year

• Coarse Turf Grass on Levee

Trail Atop Levee

Trail in Ponding Area

Pump Station

Existing Trail

Service Drive

Page 20: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 20

Community Amenities

Playground Area in Farrington Park• Worked with Community Group in Fall 2015

• Separate Equipment for Age Groups

• Construction in December 2016/ January 2017

Page 21: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 21

Community Amenities

Playground Area in Farrington Park – Proposed Design

Page 22: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 22

Flood Modelling Results

Protection of Homes from 100-Year StormFlood elevation 1-ft below lowest home opening

Page 23: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 23

Flood Modelling Results

100-year Stormwater Ponding

Some Street Flooding, but Water Surface Elevation Below Structures

Page 24: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 24

Flood Modelling Results

25-year Stormwater Ponding

Some Street Flooding, but Water Surface Elevation Below Structures

Page 25: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 25

Flood Modelling Results

10-year Stormwater Ponding

Some Street Flooding, but Water Surface Elevation Below Structures

Page 26: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 26

Permitting Update

All Permitting Completed

• Joint Permit Application (Wetlands)

• Conditional Letter of Map Revision (CLOMR)

• DEQ Stormwater Permit

• Building Permit

• Site Permit

• Zoning

• Floodplain Study

Page 27: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 27

Permitting Update

Permitting Requirements

• Construction Limits marked with 4-foot tall orange fencing

• Non-impacted surface waters with 50-feet of construction limits clearly demarcated

• Monthly DEQ inspection checklist

• Inspections by DEQ and US Army Corps of Engineers

Tree Preservation Areas

Levee

Page 28: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 28

Schedule

• Phase II (January 2014-Winter 2017)

Schematic Design (30%)

Design Development (60%)

Permitting (began March 2015)

Land Acquisition (began September 2014)

Construction Documents

• Bidding

• Phase III (Winter 2017-Spring 2019)

• Construction

Project Remains on Schedule

Page 29: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 29

Environmental Design

Envision• Rating System for Infrastructure Projects

• Bronze Level

• Similar to LEED

• 5 Categories:

• Quality of Life

• Leadership

• Resource Allocation

• Natural World

• Climate and Risk

Page 30: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 30

Community Outreach

Page 31: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 31

Community Outreach

Page 32: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 32

Community Outreach

• Bi-annually

• Important Milestones

• Next Community meeting – Spring 2017

Community Meetings

Page 33: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 33

Community Outreach

• Similar to current response

• Contractor responsible to maintain current condition (no worse)

• Temporary pumping as needed

• Contractor will be notified when County dispatches to site

Storm Events

Page 34: Community MeetingBuilding Design and Construction Division 4 Project Background •July 2014 –Hydraulic and Hydrologic Modelling for Cameron Run •September 2014 –Schematic (30%)

Building Design and Construction Division 34

Community Outreach

Contact Information – Huntington Levee Project Phone #: 703-324-5800

Email address: [email protected]

Huntington Levee Website: www.fairfaxcounty.gov/dpwes/huntingtonlevee

To request this document in an alternate format call 703-324-5800, TTY 711.