PROFIBUS/MPI Ethernet NT50-MPI NL50-MPI NT 50-MPI 580,- NL 50-MPI 510,- +24 V C OMMUNICATION All prices in euro excluding VAT PROTOCOL CONVERTER netLINK / netTAP-MPI - Ethernet to MPI / DP / PPI Converter for SIMATIC S7 ® MICRO-CONVERTER PRICE Article Description in Euro Micro-converter Ethernet TCP/IP to S7-MPI/PROFIBUS-DP (up to 12Mbps) in the box of a NetTAP50. Supply: 24VDC. For the use with STEP ® 7 of SIEMENS. Micro-converter Ethernet TCP/IP to S7-MPI/PROFIBUS-DP (up to 12Mbps) in the box of a Profibus-connector. Supply: 24VDC or via PG-Connector. For the use with STEP ® of SIEMENS Technical Data netLINK MPI netTAP MPI Operating Temperature ±0°C … +55°C ±0°C … +60°C Power supply +18 … +30 V/approx. 60mA @ +24 V +18 … +30 V/approx. 130mA @ +24 V Dimensions (L x W x H) 65 x 48 x 16 mm 100 x 52 x 70 mm Supply Mini-COMBICON 3,81mm 2-pole or Mini-COMBICON 3,81mm 2-pole S7 DSub-9 MPI / PROFIBUS Processor netX 50 netX 50 Interfaces Fast Ethernet 10/100 BASE-TX, Fast Ethernet 10/100 BASE-TX, MPI/PROFIBUS 12 MBaud IEC 61158 MPI/PROFIBUS 12 MBaud IEC 61158 LEDs SYS, COM, ACT, LNK SYS, COM, ACT, LNK Weight approx. 40 g approx. 150 g Emission CISPR 11 Class A CISPR 11 Classe A Noise Immunity EN 61131-2:2003 EN 61131-2:2003 Supoorted PLCs SIMATIC S7 ® 200,300,400 CPU/CPs SIMATIC S7 ® 200,300,400 CPU/CPs with MPI/PROFIBUS/PPI Interface with MPI/PROFIBUS/PPI Interface Highlights Parallel communication to 32 PLCs with up to 16 TCP connections Direct PLC to PLC communication, also as projected connection For all S7 Engineering Tools inclusive TIA Portal Web based confi guration, protocol support of RFC1006 and DHCP Full access to PROFIBUS diagnostics and services in STEP7 ® Automatic DP/MPI baud rate detection Controller Programming Tool Visualization System As directly mountable or as firmly attachable DIN rail mountable device the adaptors netLINK- and netTAP-MPI are replacing expensive CP communications processors and allow the programming, visualization and control of S7-200 ® , S7-300 ® or S7-400 ® PLCs over Ethernet. The provided driver integrates into all well-known SIMATIC S7 ® engineering tools like STEP7 ® or TIA portal as PG/PC programming interface. The device is setup within the engineering tool or with conventional web browsers over the integrated web confi guration pages. The adaptors are suitable to program or change S7-PLC control programs and may serve to engineer HMI devices with the visualization software WinCC. By supporting the „ISO on TCP“ RFC1006 Ethernet protocol any third party or SIMATIC ® visualization stations can be coupled to the PLC. Once integrated into the office or plant network and connected to the internet also remote maintenance and logging over a router is possible since plain TCP/IP protocol access mechanisms are used. Organized in a network direct communication between two or several PLCs over Ethernet can be realized. Even a coupling of PLCs with no own Ethernet port is possible using two adapters in conjunction. Featuring full PROFIBUS diagnostics and Master Class 2 DPV1 services enables unrestricted DP Slave device configuration and parameterization in STEP7 ® . Power is supplied by a 24 V DC. If supported by the S7 PLC the netLINK-MPI adaptor may be powered over the DSUB9 connector alternatively and its extra feed-through DSUB9 connector allows the connection of further devices to the same MPI/DP network. Ethernet upgrade for S7-PLCs with MPI/DP/PPI port

COMMUNICATION PROTOCOL CONVERTERS - Gogatec

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: COMMUNICATION PROTOCOL CONVERTERS - Gogatec

PROFIBUS/MPI

Ethernet

NT50-MPINL50-MPI

NT 50-MPI 580,-

NL 50-MPI 510,-

+24 V

COMMUNICATION

VIPA Elektronik-Systeme GmbH [email protected] Phone: +43/1/895 93 63 – 0 / Fax: – 50 www.vipa.at

36

All prices in euro excluding VAT

PROTOCOL CONVERTER

netLINK / netTAP-MPI - Ethernet to MPI / DP / PPI Converter for SIMATIC S7®

MICRO-CONVERTER PRICE Article Description in Euro

Micro-converter Ethernet TCP/IP to S7-MPI/PROFIBUS-DP (up to 12Mbps) in the box of a NetTAP50. Supply: 24VDC. For the use with STEP®7 of SIEMENS.

Micro-converter Ethernet TCP/IP to S7-MPI/PROFIBUS-DP (up to 12Mbps) in the box of a Profibus-connector. Supply: 24VDC or via PG-Connector. For the use with STEP® of SIEMENS

Technical Data

netLINK MPI netTAP MPI Operating Temperature ±0°C … +55°C ±0°C … +60°C Power supply +18 … +30 V/approx. 60mA @ +24 V +18 … +30 V/approx. 130mA @ +24 V Dimensions (L x W x H) 65 x 48 x 16 mm 100 x 52 x 70 mm

Supply Mini-COMBICON 3,81mm 2-pole orMini-COMBICON 3,81mm 2-pole

S7 DSub-9 MPI / PROFIBUS

Processor netX 50 netX 50

Interfaces Fast Ethernet 10/100 BASE-TX, Fast Ethernet 10/100 BASE-TX, MPI/PROFIBUS 12 MBaud IEC 61158 MPI/PROFIBUS 12 MBaud IEC 61158

LEDs SYS, COM, ACT, LNK SYS, COM, ACT, LNK Weight approx. 40 g approx. 150 g Emission CISPR 11 Class A CISPR 11 Classe A Noise Immunity EN 61131-2:2003 EN 61131-2:2003

Supoorted PLCsSIMATIC S7® 200,300,400 CPU/CPs SIMATIC S7® 200,300,400 CPU/CPs with MPI/PROFIBUS/PPI Interface with MPI/PROFIBUS/PPI Interface

Highlights • Parallel communication to 32 PLCs with up to 16 TCP connections • Direct PLC to PLC communication, also as projected connection • For all S7 Engineering Tools inclusive TIA Portal • Web based confi guration, protocol support of RFC1006 and DHCP • Full access to PROFIBUS diagnostics and services in STEP7® • Automatic DP/MPI baud rate detection

Controller

Programming Tool

Visualization System

As directly mountable or as firmly attachable DIN rail mountable device the adaptors netLINK- and netTAP-MPI are replacing expensive CP communications processors and allow the programming, visualization and control of S7-200®, S7-300® or S7-400® PLCs over Ethernet. The provided driver integrates into all well-known SIMATIC S7® engineering tools like STEP7® or TIA portal as PG/PC programming interface. The device is setup within the engineering tool or with conventional web browsers over the integrated web confi guration pages. The adaptors are suitable to program or change S7-PLC control programs and may serve to engineer HMI devices with the visualization software WinCC. By supporting the „ISO on TCP“ RFC1006 Ethernet protocol any third party or SIMATIC® visualization stations can be coupled to the PLC.

Once integrated into the office or plant network and connected to the internet also remote maintenance and logging over a router is possible since plain TCP/IP protocol access mechanisms are used. Organized in a network direct communication between two or several PLCs over Ethernet can be realized. Even a coupling of PLCs with no own Ethernet port is possible using two adapters in conjunction. Featuring full PROFIBUS diagnostics and Master Class 2 DPV1 services enables unrestricted DP Slave device configuration and parameterization in STEP7®. Power is supplied by a 24 V DC. If supported by the S7 PLC the netLINK-MPI adaptor may be powered over the DSUB9 connector alternatively and its extra feed-through DSUB9 connector allows the connection of further devices to the same MPI/DP network.

Ethernet upgrade for S7-PLCs with MPI/DP/PPI port

Page 2: COMMUNICATION PROTOCOL CONVERTERS - Gogatec

NL 51N-DPL 200,-

NL51-DPL

NT51-PROXY

PROFINET Device

+24 V

PROFIBUS Device

COMMUNICATION

VIPA Elektronik-Systeme GmbH [email protected] Phone: +43/1/895 93 63 – 0 / Fax: – 50 www.vipa.at

37

All prices in euro excluding VATAll prices in euro excluding VAT

PROTOCOL CONVERTER netLINK51 PROXY - PROFIBUS to PROFINET PROXY in connector format

netLINK PROXY integrates a PROFIBUS-DP slave into any superordinate PROFINET network. As connector the device is plugged directly onto the PROFIBUS-DP interface of the DP-Slave and connects to the PROFINET network via its RJ45 socket. On PROFINET side netLINK behaves like an ordinary IO device. The DP-Slave’s process data are mapped in accordance with the present PI-organisation’s guideline into the PROFINET slot/subslot addressing model. Commissioning is done via the Ethernet port with either a direct connection to the PC or if already installed and during run time via a PROFINET switch. netLINK PROXY is configured with the FDT/DTM based planning, configuration and diagnostic tool SYCON.net.

With few steps netLINK is getting operative. In case there is no slave GSD file available, a scan function is able to identify the slave on PROFIBUS. After the configuration and the I/O process data length is known, SYCON.net converts the parameters automatically into a standardized GSDML file. This file imports to any PROFINET controller configuration utility and gets netLINK into operation effortless. The netLINK Proxy is supplied by 24 V. During mounting the voltage can be tapped comfortably from the DP-Slave and be led to the 2-pin COMBICON connector. The short distance on PROFIBUS makes a terminator unnecessary. netLINK PROXY – a cost-efficient and handy alternative to redevelopments to get existing DP devices integrated straightforward into the PROFINET world.

MICRO-CONVERTER PRICE Article Description in Euro

Micro converter ProfiNet to PROFIBUS-DP-Link (up to 12MBd) in the box of a Profibus-connector. Power supply: 24VDC

Controller

Highlights • Integrates a single DP-Slave into PROFINET network • For direct mounting on DP interface • Compatible to any PROFIBUS Slave • Automatic GSDML file generation from GSD file for PROFINET controller configuration • Works in accordance with PI-organization’s proxy guideline

Turning any PROFIBUS slave into PROFINET device

Technical Data

netLINK 51 PROXY

Operating Temperature ±0°C … +50°C

Power supply +18 … +30 V/approx. 100mA @ +24 V Dimensions (L x W x H) 65 x 48 x 16 mm Processor netX 50

Mini-COMBICON 2-pole Connectors RJ45-female connector

DSub 9-pin male connector Emission CISPR 11 Class A Noise Immunity EN 61131-2:2003 Weight approx. 40 g LEDs SYS, COM,Link, Rx/Tx Certifications CE Sign

Page 3: COMMUNICATION PROTOCOL CONVERTERS - Gogatec

NT50-MPI

NT 50-RS-EN 263,-

NT 50-CO-RS 263,-

NT 50-CO-EN 263,-

NT 50-DN-RS 263,-

NT 50-DN-EN 263,-

NT 50-DP-RS 263,-

NT 50-DP-EN 263,-

COMMUNICATION

VIPA Elektronik-Systeme GmbH [email protected] Phone: +43/1/895 93 63 – 0 / Fax: – 50 www.vipa.at

36

All prices in euro excluding VAT

PROTOCOL CONVERTER

netTAP 50 - Low-Entry Gateway for Industrial Automation networks

netTAP 50 is a protocol converter for simple conversions. netTAP 50 converts 1-port Real-Time Ethernet, fieldbus and serial automation protocols. Slave to slave or slave to master conversions are supported. As a master, netTAP 50 provides full master functionality to one slave device only. This makes it easy to integrate a single field device into any higher-level network. The design impresses with a cost-optimized, compact hardware implementation being reduced to the elementary requirements of a protocol converter. The converter addresses market segments which set the focus on cost savings. The cost-reduced design combined with its countless conversion possibilities

makes netTAP 50 an attractive gateway in terms of price and universality. netTAP is configured and diagnosed by the universal FDT/DTM technology based configuration tool SYCON.net. LED indicators are visualizing status information for rapid on-site diagnostics. The protocol conversions are preprogrammed and loaded as firmware into the device on demand. Conversions needing the same physical network interface can be managed by a single device variant. So a device can be for example a PROFIBUS slave on one hand or a PROFIBUS master by a simple firmware change on the other.

PROTOCOL CONVERTER PRICE Order No.: Data in Euro

netTAP50 Gateway RS232/422/485 - Ethernet

netTAP50 Gateway CANopen - RS232/422/485

netTAP50 Gateway CANopen - Ethernet

netTAP50 Gateway DeviceNet - RS232/422/485

netTAP50 Gateway DeviceNet - Ethernet

netTAP50 Gateway PROFIBUS-DP - RS232/422/485

netTAP50 Gateway PROFIBUS-DP - Ethernet

Highlights • Parallel communication to 32 PLCs with up to 16 TCP connections • Direct PLC to PLC communication, also as projected connection • For all S7 Engineering Tools inclusive TIA Portal • Web based configuration, protocol support of RFC1006 and DHCP

I/O protocol gateway for basic conversions

Technical Data

netTAP 50

Operating temperature ±0… +60 °C Power Supply +18 … +30 V / 130 mA @ +24 V Dimensions (L x W x H) 100 x 25 x 70 mm (without connector) Weight approx. 80 g Diagnostic Interface Ethernet, RJ45-Buchse Displays SYS, COM,Link, Rx/Tx, protocol specific Configuration SYCON.net, Windows® 7 or higher Connector Mini-COMBICON 2-pin Mounting DIN-Rail, DIN EN 60715 Certification CE Sign RS232/485/422 not electrically isolated Emission CISPR 11 Class A Noise Immunity EN 61131-2:2003

Maximum Cyclic Process Data Master Slave

ASCII 1000 Bytes I/O-Data CANopen 1024 1024 Bytes I/O-Data CC-Link 736 Bytes I/O-Data DeviceNet 510 510 Bytes I/O-Data EtherNet/IP 1008 1008 Bytes I/O-Data Modbus RTU 1024 1024 Bytes I/O-Data Modbus TCP 1024 1024 Bytes I/O-Data PROFIBUS 488 488 Bytes I/O-Data PROFINET 2048 2048 Bytes I/O-Data

Ordering example: PROFIBUS Master to EtherNet/IP Slave = NT 50-DP-EN * Master license included; supports Master functionality to one slave (Modbus RTU/TCP without limitations)

The maximum convertible number of I/O data of a protocol combination is determined by the protocol with the lower amount if I/O Data. Note: All technical data may be changed without further notice.

Page 4: COMMUNICATION PROTOCOL CONVERTERS - Gogatec

NT 100-CO-DN 603,-

NT 100-CO-DP 603,-

NT 100-DN-CO 603-

NT 100-DN-DP 603,-

NT 100-DP-CO 603,-

NT 100-DP-DN 603,-

NT 100-DP-DP 603,-

NT 100-DP-RS 481,-

NT 100-RE-RS 481,-

NT 100-RE-CO 603,-

NT 100-RE-DN 603,-

NT 100-RE-DP 603,-

MASTERLIZENZ 167,-

MRPLiezenz 167,-

NT100-MPI

Highlights • Parallel communication to 32 PLCs with up to 16 TCP connections • Direct PLC to PLC communication, also as projected connection • For all S7 Engineering Tools inclusive TIA Portal • Web based configuration, protocol support of RFC1006 and DHCP

Technical Data

netTAP 100

Operating temperature ±0… +60 °C Power Supply +18 … +30 V / 130 mA @ +24 V Dimensions (L x W x H) 100 x 52 x 70 mm (without connector) Weight approx. 150 g Diagnostic Interface Mini USB Displays SYS, COM, Link, Rx/Tx, protocol specific Configuration SYCON.net, Windows® 7 or higher Connector Mini-COMBICON 2-pin Mounting DIN-Rail, DIN EN 60715 Certification CE Sign, UL 508 Emission CISPR 11 Class A Noise Immunity EN 61131-2:2003

COMMUNICATION

VIPA Elektronik-Systeme GmbH [email protected] Phone: +43/1/895 93 63 – 0 / Fax: – 50 www.vipa.at

37

All prices in euro excluding VATAll prices in euro excluding VAT

PROTOCOL CONVERTER

netTAP 100 - High-end Gateway for Industrial Automation networks

PROTOCOL CONVERTER PRICE Order No.: Data in Euro

netTAP100 Gateway CANopen - DeviceNet

netTAP100 Gateway CANopen - PROFIBUS-DP

netTAP100 Gateway DeviceNet - CANopen

netTAP100 Gateway DeviceNet - PROFIBUS-DP

netTAP100 Gateway PROFIBUS-DP - CANopen

netTAP100 Gateway PROFIBUS-DP - DeviceNet

netTAP100 Gateway PROFIBUS-DP - PROFIBUS-DP

netTAP100 Gateway serial RS232/422/485 - PROFIBUS-DP

nnetTAP100 Gateway serial RS232/422/485 - fieldbus

netTAP100 Gateway RT-Ethernet - DeviceNet

netTAP100 Gateway RT-Ethernet - PROFIBUS-DPP

netTAP100 Gateway RT-Ethernet - Modbus TCP

Master / Controller License for RT-Ethernet, PROFIBUS-DP a.s.o.

MRP extension for PN master license

netTAP 100 is the protocol converter for sophisticated conversions and supports 2-port Real-Time Ethernet to serial, Fieldbus to Fieldbus, Real-Time Ethernet to Fieldbus and Real-Time Ethernet to Ethernet automation protocols. It supports slave and master functionality in any combination. Master functionality is unrestricted when licensed. A memory card slot allows the user to save firmware and configuration data on a removable card. In case of failure all that is necessary to bring the plant back on line within seconds is to move the memory card from the old netTAP 100 onto a spare unit. Apart from standard protocols, netTAP 100 supports the creation of serial protocols with the Lua-based scripting language netSCRIPT. A full featured development environment is included within the delivery. It allows the comfortable and rapid programming of any proprietary serial protocol as well as the I/O data pre-processing during the conversion into the other field protocol.

I/O protocol gateway for demanding conversions

Ordering example: PROFIBUS Master to EtherNet/IP Slave = NT 100-RE-DP * Master license must be ordered separately (Modbus RTU/TCP without limitations)

Maximum Cyclic Process Data Master Slave

ASCII 1024 Bytes I/O-Data CANopen 7168 1024 Bytes I/O-Data CC-Link 736 Bytes I/O-Data DeviceNet 7168 510 Bytes I/O-Data EtherCAT 11472 400 Bytes I/O-Data EtherNet/IP 11472 1008 Bytes I/O-Data Modbus RTU 11520 11520 Bytes I/O-Data Modbus TCP 1024 1024 Bytes I/O-Data netSCRIPT 2048 Bytes I/O-Data POWERLINK 2980 Bytes I/O-Data PROFIBUS 11472 488 Bytes I/O-Data PROFINET 11472 2048 Bytes I/O-Data Sercos 11472 256 Bytes I/O-Data

The maximum convertible number of I/O data of a protocol combination is determined by the protocol with the lower amount if I/O Data. Note: All technical data may be changed without further notice.

Page 5: COMMUNICATION PROTOCOL CONVERTERS - Gogatec

NT 151-RE-RE 602,-

167,-

MRPLizenz 167,-

NT151-RE-RE

All prices in euro excluding VAT

VIPA Elektronik-Systeme GmbH [email protected] Phone: +43/1/895 93 63 – 0 / Fax: – 50 www.vipa.at

COMMUNICATION

38

PROTOCOL CONVERTER

netTAP 151 - High-end Gateway for Real-Time Ethernet Networks

PROTOCOL CONVERTER PRICE Order No.: Data in Euro

netTAP151 Gateway RT-Ethernet - RT-Ethernet

MASTERLIZENZ Master / Controller License for RT-Ethernet

MRP extension for PN master license

The gateway netTAP 151 transmits IO data bidirectionally between any two industrial Real-Time Ethernet networks. It is the ideal solution for installations with heterogeneous networks or such of the same kind to exchange data across given network boundaries. With more than 25 different combinations of the protocols PROFINET, EtherCAT, EtherNet/IP, POWERLINK, Sercos and Modbus TCP, the device series provides a solution for any conversion. The integration as simple I/O device into the primary network makes the converter compatible with any common PLC. On the secondary side it works either as I/O device too or controls a subordinate network as a bus master. The length of the I/O data can be scaled to any application and the data in between can be mapped on byte level arbitrarily.

Secure network separation is provided by two Ethernet controllers, each connected to a Dual Ethernet port with integrated switch. That allows realizing star, ring and inline network topologies without further peripherals. Both controllers handle the protocols independent from each other and exchange only the I/O data across a data buffer. An overall data processing time lower than 10 milliseconds is achieved. The devices can be ordered preloaded with fi rmware and license or unloaded. Unloaded devices minimize the storage costs. Subsequent loading of a firmware configures these devices for any conversion most fl exible. All devices are commissioned and diagnosed network independent over USB.

I/O protocol gateway for basic conversions

Highlights • Bridging between two Real-Time Ethernet networks • Flexible choice of operating modes Slave/Master or Slave/Slave • Effortless integration as standard I/O device • Secure network segregation via internal data buffer • Fast conversion time less than 10 milliseconds

Technical Data

netTAP151

Operating temperature -20 °C .. +60 °C Power Supply +18 … +30 V / 190 mA @ +24 V Dimensions (L x W x H) 99 x 22,5 x 114,5 mm (without connector) Weight 121 g Service Interface Mini USB Displays LED SYS, APL, protocol specific Configuration SYCON.net, Windows® 7 Connector Mini-COMBICON 5-pin Mounting DIN-Rail, DIN EN 60715 Emission EN55011 / CISPR 11 Class A Noise Immunity EN 61000-6-2 Certification CE Sign, UL, cUL Card Slot SD card

Maximum Cyclic Process Data Master Slave

EtherCAT 9200 512 Bytes I/O-Data

EthetNet/IP 11472 1008 Bytes I/O-Data POWERLINK 1490 Bytes I/O-Data PROFINET 11472 1048 Bytes I/O-Data Sercos 11472 240 Bytes I/O-Data Modbus TCP 11520 11520 Bytes I/O-Data

The maximum convertible number of I/O data of a protocol combination is determined by the protocol with the lower amount if I/O Data. Note: All technical data may be changed without further notice.

Note: All technical data may be changed without further notice.