2
Communication interfaces USB / RS485 interface USB RS485 DIRIS A20 DIRIS A40 Casing USB / RS485 Laptop < 1200 m < 31 devices (1) COUNTIS ECi inter_142_g_1_gb_cat (1) Beyond these characteristics, use an " RS422 / RS485 repeater". inter_002_a_2_cat If the PC is not equipped with a serial port, this interface can be connected via a USB port to obtain an RS485 communication port. Recommended for local use and not for permanent installation. Description of accessories Reference External USB / RS485 interface unit 4899 0110 References Function inter_151_b_gb Connecting the RS485 link Communication accessories Modbus/Profinet communication gateway The PROFINET communication gateway enables SOCOMEC communicating products in TCP modbus to be connected to a PROFINET network. Implementation, maintenance and diagnostic with a unique configuration software (Sycon.net), which is downloadable from SOCOMEC website. Several communication ports. IP20 DIN-rail mounting. Slot for MMC memory card. Configuration via USB port using a PC. Operation signalling Leds. Modbus data conversion up to 512 bytes data with Profinet (Modbus slave). Function Advantages LINK L/A ACT Rx/Tx LINK L/A ACT Rx/Tx RUN STOP RES DIAG MMC APL SYS CH1 OUT CH0 IN X1 X2 LINK ACT X3 Memory 8 MB SDRAM 4 MB serial Flash MMC card (optional) 2 GByte max Power supply Voltage 24 V ± 6 V DC - reverse pole protected 24 V current (typical) 130 mA 3.2 W power consumption Mini-COMBICON, 2-pin connector Configuration interface USB Operating temperature 0 … + 60 °C Dimensions W x H x D 100 x 70 x 52 mm (without connector) Configuration Modbus RTU DIRIS B-30 DIRIS G Modbus RTU DIRIS A DIRIS Digiware RS485 RS485 Ethernet Ethernet Modbus TCP Profinet Logic controllers inter_150_b Description of accessories Reference Profinet / Modbus-TCP interface 4899 0301 612 General Catalogue 2017-2018

Communication accessories - Socomec · Communication interfaces USB / RS485 interface USB RS485 DIRIS A20 DIRIS A40 Casing USB / RS485 Laptop < 1200 m < 31 devices(1) COUNTIS ECi

  • Upload
    others

  • View
    46

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Communication accessories - Socomec · Communication interfaces USB / RS485 interface USB RS485 DIRIS A20 DIRIS A40 Casing USB / RS485 Laptop < 1200 m < 31 devices(1) COUNTIS ECi

Co

mm

unic

atio

n in

terf

aces

USB / RS485 interface

USB RS485

DIRIS A20 DIRIS A40Casing

USB / RS485

Laptop

< 1200 m< 31 devices(1)

COUNTIS ECi

COUNTIS E Ci3

inte

r_14

2_g_

1_gb

_cat

(1) Beyond these characteristics, use an " RS422 / RS485 repeater".

inte

r_00

2_a_

2_ca

t If the PC is not equipped with a serial port, this interface can be connected via a USB port to obtain an RS485 communication port.Recommended for local use and not for permanent installation.

Description of accessories Reference

External USB / RS485 interface unit 4899 0110

References

Function

inte

r_15

1_b_

gb

Connecting the RS485 link

Communication accessories

Modbus/Profinet communication gateway

The PROFINET communication gateway enables SOCOMEC communicating products in TCP modbus to be connected to a PROFINET network.

Implementation, maintenance and diagnostic with a unique configuration software (Sycon.net), which is downloadable from SOCOMEC website. • Several communication ports. • IP20 DIN-rail mounting. • Slot for MMC memory card. • Configuration via USB port using a PC. • Operation signalling Leds. • Modbus data conversion up to 512 bytes data with Profinet(Modbus slave).

Function

AdvantagesLINKL/A

ACTRx/TxLINKL/A

ACTRx/Tx

RUNSTOPRES

DIAG

MM

CA

PL S

YS

CH1

O

UT

CH

0

IN

X1

X2

LINK

ACTX3

Memory

8 MB SDRAM

4 MB serial Flash

MMC card (optional) 2 GByte max

Power supply

Voltage 24 V ± 6 V DC - reverse pole protected

24 V current (typical) 130 mA

3.2 W power consumption

Mini-COMBICON, 2-pin connector

Configuration interface USB

Operating temperature 0 … + 60 °C

Dimensions W x H x D 100 x 70 x 52 mm (without connector)

Configuration

ModbusRTU DIRIS B-30

DIRIS G

ModbusRTUDIRIS A

DIRIS Digiware

RS485

RS485

Ethernet Ethernet

ModbusTCP

Profinet

Logiccontrollers

LINKL/A

ACTRx/TxLINKL/A

ACTRx/Tx

RUNSTOPRES

DIAG

MM

CA

PL

SY

S

CH

1

OU

T

C

H0

IN

X1

X2

LINK

ACTX3

inte

r_15

0_b

Description of accessories Reference

Profinet / Modbus-TCP interface 4899 0301

Communication accessories

RS422 / RS485 repeater

BLB

LN

BLARDA RDB

PWR

R- R+ T- T+

R-R+T-T+

POWER

LINE-B

LINE-A

RS422/RS485REPEATER

DIRIS A40

DIRIS A40

RS485 RS485

DIRIS A40

RS485

BLB

LN

BLARDA RDB

PWR

R- R+ T- T+

R-R+T-T+

POWER

LINE-B

LINE-A

RS422/RS485REPEATER

1200

m

DIRIS A40

RS485

BLB

LN

BLARDA RDB

PWR

R- R+ T- T+

R-R+T-T+

POWER

LINE-B

LINE-A

RS422/RS485REPEATER

1200

m

RS232 / RS485Interface

RS232

< 1200 m< 31 devices

PC

ORothers

systems

ORprogrammable

logic controllers

COUNTIS ECi COUNTIS ECi

COUNTIS ECi

COUNTIS ECi

COUNTIS E Ci3

COUNTIS E Ci3

COUNTIS E Ci3

COUNTIS E Ci3

inte

r_14

3_h_

1_gb

_cat

inte

r_01

1_a

In some applications the maximum distance and/or the maximum number of devices can be exceeded. One solution to this technical restriction is to install an interface which amplifies the signal over a further 1200 m (at 9600 bauds) for 31 devices.In addition, it allows you to introduce a new branch to the network, thereby making it possible to reduce the length of connection cable required by avoiding back and forth cabling.

Auxiliary power supply Us Frequency Reference

95 … 240 VAC / 110 … 250 VDC 50 Hz 4899 0120

References

Function

Other solutions and services

mes

ur_1

12_d

_1_g

b_ca

t

COCOCUNTISTIST

E 50

M

DIRISA40

COUNTISCOUNTISCE30

DIRISA10

COUNTISCOUNTISCE40

COUNTISCOUNTISCE50

DIRISA20

COUNTISCOUNTISCE00

OUNTISECi

RS485

RS485

BMS/CTM

PLC

GatewayTCP/IP

GatewayTCP/IP

DIRISA40 The accessories listed in these pages represent a selection from our range.

We can supply many other solutions upon request, such as SHDSL interfaces, fibre optics/RS485, GSM/GPRS and protocol converter interfaces.

Need something integrating into your network?No problem for our Expert Services team. They will fully integrate all your SOCOMEC devices, audit your system, commission selected equipment and train your staff on its use.For further information, please contact your nearest SOCOMEC branch.

612 General Catalogue 2017-2018

Page 2: Communication accessories - Socomec · Communication interfaces USB / RS485 interface USB RS485 DIRIS A20 DIRIS A40 Casing USB / RS485 Laptop < 1200 m < 31 devices(1) COUNTIS ECi

Co

mm

unic

atio

n in

terf

aces

USB / RS485 interface

USB RS485

DIRIS A20 DIRIS A40Casing

USB / RS485

Laptop

< 1200 m< 31 devices(1)

COUNTIS ECi

COUNTIS E Ci3

inte

r_14

2_g_

1_gb

_cat

(1) Beyond these characteristics, use an " RS422 / RS485 repeater".

inte

r_00

2_a_

2_ca

t If the PC is not equipped with a serial port, this interface can be connected via a USB port to obtain an RS485 communication port.Recommended for local use and not for permanent installation.

Description of accessories Reference

External USB / RS485 interface unit 4899 0110

References

Function

inte

r_15

1_b_

gb

Connecting the RS485 link

Communication accessories

Modbus/Profinet communication gateway

The PROFINET communication gateway enables SOCOMEC communicating products in TCP modbus to be connected to a PROFINET network.

Implementation, maintenance and diagnostic with a unique configuration software (Sycon.net), which is downloadable from SOCOMEC website. • Several communication ports. • IP20 DIN-rail mounting. • Slot for MMC memory card. • Configuration via USB port using a PC. • Operation signalling Leds. • Modbus data conversion up to 512 bytes data with Profinet(Modbus slave).

Function

AdvantagesLINKL/A

ACTRx/TxLINKL/A

ACTRx/Tx

RUNSTOPRES

DIAG

MM

CA

PL S

YS

CH1

O

UT

CH

0

IN

X1

X2

LINK

ACTX3

Memory

8 MB SDRAM

4 MB serial Flash

MMC card (optional) 2 GByte max

Power supply

Voltage 24 V ± 6 V DC - reverse pole protected

24 V current (typical) 130 mA

3.2 W power consumption

Mini-COMBICON, 2-pin connector

Configuration interface USB

Operating temperature 0 … + 60 °C

Dimensions W x H x D 100 x 70 x 52 mm (without connector)

Configuration

ModbusRTU DIRIS B-30

DIRIS G

ModbusRTUDIRIS A

DIRIS Digiware

RS485

RS485

Ethernet Ethernet

ModbusTCP

Profinet

Logiccontrollers

LINKL/A

ACTRx/TxLINKL/A

ACTRx/Tx

RUNSTOPRES

DIAG

MM

CA

PL

SY

S

CH

1

OU

T

C

H0

IN

X1

X2

LINK

ACTX3

inte

r_15

0_b

Description of accessories Reference

Profinet / Modbus-TCP interface 4899 0301

Communication accessories

RS422 / RS485 repeater

BLB

LN

BLARDA RDB

PWR

R- R+ T- T+

R-R+T-T+

POWER

LINE-B

LINE-A

RS422/RS485REPEATER

DIRIS A40

DIRIS A40

RS485 RS485

DIRIS A40

RS485

BLB

LN

BLARDA RDB

PWR

R- R+ T- T+

R-R+T-T+

POWER

LINE-B

LINE-A

RS422/RS485REPEATER

1200

m

DIRIS A40

RS485

BLB

LN

BLARDA RDB

PWR

R- R+ T- T+

R-R+T-T+

POWER

LINE-B

LINE-A

RS422/RS485REPEATER

1200

m

RS232 / RS485Interface

RS232

< 1200 m< 31 devices

PC

ORothers

systems

ORprogrammable

logic controllers

COUNTIS ECi COUNTIS ECi

COUNTIS ECi

COUNTIS ECi

COUNTIS E Ci3

COUNTIS E Ci3

COUNTIS E Ci3

COUNTIS E Ci3

inte

r_14

3_h_

1_gb

_cat

inte

r_01

1_a

In some applications the maximum distance and/or the maximum number of devices can be exceeded. One solution to this technical restriction is to install an interface which amplifies the signal over a further 1200 m (at 9600 bauds) for 31 devices.In addition, it allows you to introduce a new branch to the network, thereby making it possible to reduce the length of connection cable required by avoiding back and forth cabling.

Auxiliary power supply Us Frequency Reference

95 … 240 VAC / 110 … 250 VDC 50 Hz 4899 0120

References

Function

Other solutions and services

mes

ur_1

12_d

_1_g

b_ca

t

COCOCUNTISTIST

E 50

M

DIRISA40

COUNTISCOUNTISCE30

DIRISA10

COUNTISCOUNTISCE40

COUNTISCOUNTISCE50

DIRISA20

COUNTISCOUNTISCE00

OUNTISECi

RS485

RS485

BMS/CTM

PLC

GatewayTCP/IP

GatewayTCP/IP

DIRISA40 The accessories listed in these pages represent a selection from our range.

We can supply many other solutions upon request, such as SHDSL interfaces, fibre optics/RS485, GSM/GPRS and protocol converter interfaces.

Need something integrating into your network?No problem for our Expert Services team. They will fully integrate all your SOCOMEC devices, audit your system, commission selected equipment and train your staff on its use.For further information, please contact your nearest SOCOMEC branch.

613General Catalogue 2017-2018