Upload
phamkhuong
View
218
Download
0
Embed Size (px)
Citation preview
0870 870 7500Customer Service number
Integra 1630
Gen-Trans EN/L
Elapsed Time Meter
Gen-Trans EN/D
Gen-ATS
Single-phase KWH
Three-phase KWH
New Products
1
Contents Page
Product Range 2 – 3
Integra Digital Metering Systems 4 – 7
Kilowatt Hour Energy Meters 8 – 12
Integra and Paladin Transducers 13 – 16
Protector Relays 17 – 20
Analogue Instruments 21 – 35
Selector Switches 36
Current Transformers 37 – 42
Shunts 43
Generator Set Controllers 44 – 47
Power Measurement, Control and
Protection Solutions
The Crompton Instruments business unit of Tyco Electronics offer one of the largest product ranges of power measurement, control and protection instrumentation for switchgear and generator setmanufacturers, panel builders and OEMs. Crompton branded productsoffer proven reliability across a diverse array of industries includingpower generation, process control, test and measurement, utility,marine, defence and energy management applications.
This combined catalogue and price list presents a small selection of our complete product portfolio and is in no way exhaustive.
For comprehensive information of our complete product range pleasevisit our web site www.crompton-instruments.com or ask your salesrepresentative for our CD-ROM.
Delivery Codes
A – 2-4 days
B – 5-10 days
C – 10-20 days
Z – Consult factory
*Note: max order guidelines apply
Tyco ElectronicsOver the past five years Tyco Electronics has grown rapidly to become the world’s largest passive componentmanufacturer. A complement of leading component brands such as Raychem, AMP, Elcon, P&B and manyothers, offers customers an unparalleled portfolio of connectors, relays, circuit breakers, power components,fibre optic and wireless products, motors and a myriad of others across 25 product segments.
• Surge arresters• Switching, protection and lightning • Power measurement and control
Energy Division – Connecting the world of powerThe Energy Division, a global operating unit, is focused on providing products and systems for the electricalpower industry supplying power utilities, equipment manufacturers, railways and a wide range of industries.
Each business unit within the Division comes with specialised product line and focused set of application skills for its specific market. In addition to Crompton Instruments other brands include ALR, AMP, Axicom,B&H, Bowthorpe EMP, Dorman Smith, Dulmison, Guro, Helstern, La Praire, Morlyn, Raychem and Simel.
The Energy Division is able to bring innovative and technology driven products efficiently to the market bysynchronising the product development and manufacturing facility capabilities of its brands. Significant positionin multiple market segments and its size and expertise allow the unit to provide customers with a high level ofengineering assistance and continuous after-sales support.
The Energy Division is a leading supplier of:• Cable accessories• Connectors and fittings• Insulators and insulation
2
Crompton InstrumentsBeginning with a variant of the Serrin arc lamp, CromptonInstruments has brought innovative products to market for over a century and Integra digital metering systems are just oneexample of how the technology is put to work.
The focus on measuring energy began with Colonel Crompton’spatenting the concept for a revolving energy counter and hissupport for a combined circuit that could measure both voltageand current. From this beginning, analogue instruments soonbecame Crompton Instruments’ primary product. By the 1970sthis product range had widened to include transducers, protectortrip relays and current transformers.
Progressive upgrading of discrete circuitry to micro-basedintegrated technology in the 1980s increased Crompton’scompetitive position in the marketplace. With thelaunch of the Integra 2000 digital metering system in1993, Crompton had its first digital metering system of what has since grown to become a completeproduct line.
Tyco Electronics has been able to retain in-housemanufacturing of its analogue instruments in the UK due to the focus on skilled assembly, value engineering and use of supporting Six Sigma processes.
Crompton Instruments branded products are usedthroughout the electrical energy circle, beginning with power generation and continuing to the finalconsumers of electrical power.
Crompton Instruments comprehensive measuring and controlsolutions are used by control solutions from Crompton are usedby power generators and panel builders and provide a costeffective way for panel builders to upgrade their existinganalogue equipment and an efficient alternative to multi-functionrelays. Crompton Instruments remote communication protocols allow of remote communication protocols allowsenergy managers to integrate site metering equipment intocomputer-based systems.
Crompton Instruments protector trip and meter relays are used throughout the industry. We provide OEMs with both off-the-shelf and custom solutions for test and measurementapplications. Switchgear and control panel builders are long-timeconsumers of our instruments. Regardless of the applicationCrompton Instruments branded products measure up.
Integra Digital Metering Systems
Integra multi-function metering systems measure,display and communicate over 100 parameters,including true RMS and power quality data. Integrasystems are fully programmable via a simple menu-driven interface and can be integrated into energymanagement systems via external interface options.Options include pulsed, analogue and digital outputs, a choice of DIN, ANSI case styles and LED or LCD displays.
Integra and Paladin Transducers
Transducers measure, isolate and convert electricalparameters into industry standard dc output signals and broadcast the results via communication interfaceoptions such as RS232 and Modbus®. These vibration-resistant transducers protect against high voltage andoverload. Integra transducers offer up to four userprogrammable analogue outputs and measure up to 50electrical and power quality parameters. Paladin DIN railtransducers offer multiple analogue outputs from asingle housing and Class 0.5 or 0.2 measurement of upto seven electrical parameters.
Kilowatt Hour Energy Meters
Tyco Electronics under its Crompton Instrumentsbrand offers offers self-contained panels or DIN rail-mounted meters measure combined kWh orkVArh with pulsed or analogue output options andselectable CT and VT ratios, replacing the need forseparate rotating disc meters or instantaneouswattmeters. Micro-processor controlled circuitryprovides up to Class 1.0 accuracy. Outputs aredisplayed via electro-mechanical indicators, LCDcounters or other integral instantaneous indication options.
Protector Trip Relays
Trip relays continuously monitor and protect anyelectrical parameter within a set point limit. The rangeoffers both traditional and technologically advancedproducts, including single parameter units, earth leakageprotection, ground fault relays, vector shift and ROCOFand microprocessor system protection relays.
Meter Relays & Digital Indicators
Tyco Electronics under its Crompton Instruments brandoffers a comprehensive range of meter relays and digitalindicators for measuring, monitoring and control of anyelectrical or process parameter. Meter relays are idealfor process control and load shedding applications,combining an indicator with set points which operatealarm and control circuits when the signal deviates from set limits. This range includes digital and analogue meter relays, digital bar graph indicators and controllers. Instruments are designed for controlpanels and switchboards, monitoring systems, power generation and control applications.
Current Transformers
Complete range of transformers for reducing highprimary currents down to a consistent 5 or 1 ampsecondary current. Transformer options include mouldedcase width, busbar and aperture sizes tape wound,balanced and split cores, current ratings, and variousmounting options.
Analogue Instruments
Comprehensive range of analogue instruments formeasuring electrical and electronic parameters. Rangeincludes DIN instruments, ANSI switchboard meters,panel indicators, sealed and ruggedised instruments andcomplementary selector switches for line-to-line and line-to-neutral readings. Precision engineeredinstruments are robust in design, ensuring accuratemeasurement and display in the demand environments.All instruments are available in a range of styles, sizesand specifications to meet the specific industry needs.
Shunts
Shunts provides an accurate dc millivolt signal, exactlyproportional to the system current, to drive ammeterindicators, overload protection and control devices. Therange includes industrial, switchboard, DEF 66-13, DIN,base mounted, tag end, lightweight and panel metershunts which can be supplied in a variety of formats and configurations.
Generator Set Controllers
Generator-set control units provide integrated manage-ment of all combined heat and power, co-generation,diesel and gas engine generator applications. Unitsmonitor energy supply within pre-set limits, auto-matically starting generator motors and transferringloads between mains and generator as needed. Unitscan be programmed to monitor a variety of energyparameters directly through the instrument monitor or a remote PC.
Modbus® is a trademark of Schneider Automation Inc
3
4
Integra Digital Metering Systems
OperationThe multifunction Integra 1630 digital metering system offers uncomplicated operationand high accuracy measurement of three-phase voltage, current, frequency, Watts,VAr, VA, energy, power factor and total harmonic distortion measurement of bothphase and system, current and voltage.
Three-phase four-wire system line-to-line voltage measurements are often a vectorcalculation of the line-to-neutral voltage measurements. However Integra 1630 digitalmetering system includes true measurement of both line-to-neutral, and line-to-linemeasurements, ensuring accurate readings even with unusual wiring configurations(e.g. four-wire open delta). To suit the requirements of individual power monitoringapplications, the Integra 1630 digital metering system offers simple programming anddisplay via the menu driven interface. Alternatively, an optional Windows-basedsoftware package can be used for remote configuration and monitoring. Onceconfigured by either method, simultaneous monitoring of up to 60 electrical and powerquality variables can be communicated to building management systems via pulsed ordigital communication options.
If customer requirements extend beyond the original specified capabilities, thefunctionality of this innovative product is easily enhanced to meet new clientexpectations. Integra plug-in option modules allow cost effective upgrades with anycombination of pulsed and digital communication outputs. The option module isinterchangeable without recalibration.
AccuracyIntegra 1630 digital metering systems utilise true rms measurement techniques up tothe 31st harmonic. An exceptional tolerance to high harmonic frequencies is achievedfrom a robust frequency detection method which is able to detect the fundamentalfrequency on any phase. For safe maintenance, the system indicates CT current in theabsence of voltage signals.
System Input
Designed for all low, medium and high voltage switchgear and distribution systems,the Integra 1560 and 1580 digital metering systems offer programmable VT and CTratio capability. Direct connection up to 480V ac with 5A CT inputs is standard and 1ACT inputs are optional.
DIN Integra 1630 Series
Multifunction Integra 1630 digital metering systems provide high accuracy0.2% measurement, display and communication of all major electrical and power quality parameters including total harmonic distortion (THD)measurement up to the 31st harmonic. To suit user requirements the rangeincludes single-phase, three-phase three-wire and three-phase four-wirecapability, all selectable at the point of installation.
This DIN 96 panel mounted enclosure offers simple programming and displayof up to 35 electrical measurement parameters via a simple menu-driven userinterface on the front panel. Integra 1630 digital metering system benefitsfrom optional pulsed and digital communication outputs. This allows enhancedstatus information of up to 60 measured parameters to be communicated toSCADA, building management or other systems. Additionally, a simpleWindows-based software package is available to remotely configure theIntegra and display all 60 major electrical and power quality parameters.
The Integra digital metering systems are designed to suit any powermonitoring application. These multi-function products replace the needfor numerous single function instruments, providing significant costsavings and reduced wiring times for all new or retrofit projects.
Measurement and DisplayUp to 35 electrical and power qualityparameters can be configured anddisplayed.
1 System (average) voltsSystem (average) currentSystem (total) kW
2 System volts (average) THD%System current (average) THD%
3 Volts L1–NVolts L2–NVolts L3–N(four-wire only)Volts L1–L2Volts L2–L3Volts L3–L1(three-wire only)
4 Volts L1–N THD%Volts L2–N THD%Volts L3–N THD%(four-wire only) Volts L1–L2 THD%Volts L2–L3 THD%Volts L3–L1 THD%(three-wire only)
5 Volts L1–L2Volts L2–L3Volts L3–L1 (four-wire only)
6 Current L1Current L2Current L3
7 Current line 1 THD%Current line 2 THD%Current line 3 THD%
8 Neutral current(four-wire only)FrequencyPower factor (overall)
9 kVAr kVA kW 10 kW Hr import (seven-digit
resolution) 11 kVArh import (seven-digit
resolution) 12 kW Hr export (seven-digit
resolution) 13 kVArh export (seven-digit
resolution) 14 kW demand
Current demand15 Maximum kW demand
Maximum current demand16 Hours run
5
Product Codes
I N T – X X X X – X - X – X - X X X
Product System Type Input Input Auxiliary Options
Family V I V
16 30–LED DIN96 L–57.7–139 L–N 5–5A L–12–48V dc 000 - No option(100–240 L–L) 1–1A M–100–250V 010 - Modbus®
Low User M–140–277 L–N ac/dc 100 - 1-pulseprofile selectable system (241–480 L–L) 110 - 1-pulse
type 1 Modbus®
Features as Factory default 200 - 2-pulsespecified - 4-wire 210 - 2-pulse
1 Modbus®
Order Code Example
INT-1630-M-5-M-110 Integra 1630 digital metering system, three-phase four-wire, nominal inputvoltage, 140-277V L-N (241-480V) L-L,5A CT input, auxiliary supply 100 to250V ac or dc, one relay pulsed outputand one RS485 Modbus®
communication port.
Modbus® is a trademark of SchneiderAutomation Inc
Product Description and Order Codes
Description Code
CROMPTON
3-phase 3/4-wire 100-240V L-L, 5A CT input. Aux. 100-250V ac/dc INT-1630-L-5-M-option3-phase 3/4-wire 241-480V L-L, 5A CT input. Aux. 100-250V ac/dc INT-1630-M-5-M-optionOptions No options 0001 kWhr pulsed output 1002 kWhr pulsed outputs 200RS485 interface Modbus® 010RS485 interface Modbus® +1kWhr 110
Wiring
Dimensions
6
Integra Digital Metering Systems
Series 1530
Multi-function Integra 1530 digital metering systems provide highaccuracy <0.2% measurement, display and communication of all major electrical and power quality parameters, including true rms system values, power quality data and total harmonic distortion (THD) measurement up to the 31st harmonic. To meet customer requirements, the range comes in single-phase, single-phase three-wire, three-phase three or four-wire, and three-phase four-wire with neutral CT configurations.
• DIN 96x96 format with LED display• Programmable VT and CT ratio - In/5A or In/1A• Displays: up to three parameters at a time• Front panel or Windows based software configuration with password protection• Auxiliaries: 100/250V ac/dc or 12/48V dc• Options: RS485 Modbus® RTU/Johnson Controls, Lonworks interface, Profibus pulse
outputs (kWh and KVArh) + analogue outputs• Consult customer service department
Description Code
CROMPTON
3-phase 3-wire 100-240V L-L, 5A CT INT-1533-L-5-M-option-***input. Aux. 100-250V ac/dc3-phase 3-wire 241-480V L-L, 5A INT-1533-M-5-M-option-***CT input. Aux. 100-250V ac/dc3-phase 4-wire 100-240V L-L, 5A CT INT-1534-L-5-M-option-***input. Aux. 100-250V ac/dc3-phase 4-wire 241-480V L-L, 5A INT-1534-M-5-M-option-***CT input. Aux. 100-250V ac/dcOptions-***No options 0001 kWhr pulsed output 1002 kWhr pulsed outputs 200RS485 interface Modbus® 010RS485 interface Modbus® + 1 110kWhr pulse outputRS485 interface Modbus® + 2 210kWhr pulse outputProfibus 050Lonworks 0301 analogue output (0/20mA) 001=12 analogue outputs (0/20mA) 002=1
Product Description and Order Codes
Dimensions
Connections
PANEL CUT-OUT 3.62"92mm
3.62"92mm
MAX PANEL THICKNESS 0.19", 5mm
Three-phase
four-wire
unbalance load
Three-phase
three-wire
unbalance load
Modbus® is a trademark of Schneider Automation IncLonworks is a trademark of Echelon Corporation. Profibus is a trademark of PROFIBUS Nutzerorganisation e.v
3.78"96mm
3.78"96mm
FRONT DISPLAYAREA
5.87" 149mm
5.67" 144mm
7
Integra Digital Metering Systems
Series 510
The Integra 510 generator set integrated power metering unit providescost effective digital multifunction metering. Designed for continuoususe in harsh environmental conditions, the unit typically replaces three conventional ammeters, a voltmeter, a selector switch and a frequency meter.
Integra 510 digital metering system offers a simple two-button interfacefor the measurement of up to nine electrical parameters andprogramming of current transformer ratios up to 8000A. The highcontrast large character LCD display provides readings for current perphase and system average, voltage per phase and system average, andsystem frequency.
Description Code
CROMPTON
3-phase 3-wire 400V 5A CT input. 244-513W-38LS-SPSelf powered 3-phase 3-wire 400V 5A CT input. 244-513W-38LS-19aux. 190/240V ac3-phase 4-wire 400V+N 5A CT 244-514W-38LS-SPinput. Self powered3-phase 4-wire 400V+N 5A CT 244-514W-38LS-19input. aux.190/240V ac
Product Description and Order Codes
Dimensions
Connections
Three-phase four-wire unbalanced load Three-phase three-wire unbalanced load
• DIN 96 x 96 format with LCD display• Equivalent to:
– Three ammeters– Three voltmeters– One frequency meter
• Programmable CT ratio – In/5A or In/1A• Displays: line current, voltage L-L and L-N
and system frequency• Self powered or separate auxiliary
PANEL CUT-OUT
8
Kilowatt Hour Energy Meters – DIN Rail
Single-phase: 230V – Direct Connected
Description Code
CROMPTON
1-phase 15A – pulse output DRK-1PPO-240
Description Code
CROMPTON
3-phase CT connected 5A DRK-3PCT-415Output pulse – 3 or 4-wire system
Description Code
CROMPTON
1-phase CT 5A – pulse output DRK-1PCT-240
Description Code
CROMPTON
Pulse collector – collects 8 pulsed DRK-485-230inputs to RS485 Modbus® output
Single-phase: 230V – CT Connected 5A(*)
Three-phase: 400V (+N) CT Connected 5A(*)
Concentrator Module – Pulse Collector
Self-contained energy metering system which is ideal for switchgear,plant instrumentation and process control. The range has significantadvantages over the traditional energy meters with pulsed outputs,communications and direct connection all available as options.
Modbus® is a trademark of Schneider Automation Inc*Current transformers must be ordered separately
9
Single-phase: 230V – Direct Connected 63A
Description Cat. no.
1-phase 230V–63A direct DRK-1P-230-D63connected, pulsed output (Opto)
Description Cat. no.
3-phase 230V L-N (400V L-L) – DRK-3P-400-D9090A direct connected, pulsed output (Opto)
Three-wire System Four-wire System
Connections
Three-phase: 230V (400V) – Direct Connected 90A
10
Voltage Mechanical Mechanical Import LCD Mechanicalsystem counter counter + export counter counter +
only meter counter only meter 90° scale only 240° scale
1-phase 244-HWM 244-HWG 244-HEM 244-HWS 244-HWB3-phase 3-wire 244-HWN 244-HWH 244-HEN 244-HWT 244-HWCbalanced load3-phase 3-wire 244-HW2 244-HW3 – 244-HW4 –balanced load with reversedCTs3-phase 4-wire 244-HWY 244-HWV 244-HE7 244-HWZ 244-HWUbalanced load3-phase 3-wire 244-HWP 244-HWJ 244-HEP 244-HWW 244-HWDunbalanced load3-phase 4-wire 244-HWQ 244-HWK 244-HEQ 244-HWX 244-HWEunbalanced loadTransducer 244-KWL 244-KWF – 244-KWR 244-KWAinputs
Voltage Mechanical Mechanical Import LCD Mechanical
system counter counter + export counter counter + only meter counter only meter
90° scale only 240° scale
1-phase 244-HXM 244-HXG 244-HIM 244-HXS 244-HXB3-phase 3-wire 244-HXN 244-HXH 244-HIN 244-HXT 244-HXCbalanced load3-phase 3-wire 244-HXP 244-HXJ 244-HIP 244-HXW 244-HXDunbalanced load3-phase 4-wire 244-HXQ 244-HXK 244-HIQ 244-HXX 244-HXEunbalanced loadTransducer 244-KXL 244-KXF – 244-KXR 244-KXAinputs
Ordering Codes for Wattmeters
Example: 3ph 4W unbalanced mechanical counter with 240° meter.Specify: 244-HWE followed by voltage ratio, current ratio, frequency, Fsd watts,energy/pulse and options if required.
Example: 3ph 4W unbalanced mechanical counter with 240° meter.Specify: 244-HXE followed by voltage ratio, current ratio, frequency, Fsd watts,energy/pulse and options if required.
Ordering Codes for Varmeters
OutputPulse
87 45
35 60
DRK-1PCT/3PCT/485
DRK-1PPO
Dimensions
11
* CT ratio configurable via selector switch 5,10, 25, 50, 75, 100, 125, 150, 200, 250, 300,400, 500, 600, 800 or 1000A
230 V ac 50/60Hz User Load(Max 22.5A)
5-6 Output Pulse1 Imp/0.1 kWh
Connections
DRK-1PPO Single-phase 15A DRK-1PCT Single-phase CT 5A*
DRK-485 Concentrator Module
DRK-3PCT Three-phase DRK-3PCT Three-phase
CT connected 5A(*) three-wire System CT connected 5A(*) four-wire System
OutputPulse
OutputPulse
12
CT ratio DIP switch Multiplier
setting
4 3 2 1
5/5A 1 1 1 1 0.0110/5A 1 1 1 0 0.120/5A 1 1 0 1 0.130/5A 1 1 0 0 0.140/5A 1 0 1 1 0.150/5A 1 1 1 1 0.160/5A 1 0 1 0 0.175/5A 1 0 0 1 0.180/5A 0 1 1 0 0.1100/5A 1 1 1 0 1125/5A 0 1 0 0 1150/5A 1 0 0 0 1200/5A 1 1 0 1 1250/5A 0 1 1 1 1300/5A 1 1 0 0 1400/5A 1 0 1 1 1500/5A 1 1 1 1 1600/5A 1 0 1 0 1750/5A 1 0 0 1 1800/5A 0 1 1 0 11000/5A 1 1 1 0 101200/5A 0 1 0 1 101250/5A 0 1 0 0 101500/5A 1 0 0 0 101600/5A 0 0 1 1 102000/5A 1 1 0 1 102500/5A 0 1 1 1 103000/5A 1 1 0 0 103200/5A 1 1 0 1 104000/5A 1 0 1 1 105000/5A 1 1 1 1 10
+ _
PULSEOUTPUT
L1L2L3
S1
P1S1
P1
LOAD
+ _
PULSEOUTPUT
L1L2L3N
S1
P1S1
P1
LOAD
S1
P1
S1 S2 S1 S2 L1 L2 L3 + _ S1 S2 S1 S2 L1 L2 L3 + _S1 S2 N
Kilowatt Hour Energy Meters
Panel Mount Series
Dimensions
Connections
It is recommended that all voltage lines are fitted with 1 amp HRC fuses. For safety reasons, CT secondary connections should be grounded according tolocal codes of practice.
Three-phase three-wire Unbalanced Load Three-phase four-wire Unbalanced Load
Description Code
CROMPTON
3-phase 3 or 4-wire 400V KWH-400-3P 3W5A CT input, opto pulse output
3-phase 4-wire 400V 5A CT input, KWH-400-3P4Wopto pulsed output
3-phase 4-wire 400V 5A CT input, KWH-400-3P4W-RLYrelay output
PanelCut-Out
13
Integra and Paladin Transducers
Integra 1560 multi function transducers provide high accuracy <0.2%measurements and communicate up to 50 major electrical and powerquality parameters, including true RMS system values, power qualitydata and total harmonic distortion (THD) measurement up to the 31stharmonic. Transducers meet high technical specifications andincorporate pulsed, analogue and digital communication outputs.
Operation
The multi function Integra 1560 transducer offers uncomplicated operation and highaccuracy <0.2% measurement of three-phase voltage, current, frequency, watts, VAr,VA, energy, power factor and total harmonic distortion measurement of both phase andsystem, current and voltage. A simple WindowsTM based software package is providedto configure the transducer. Once configured, up to 50 electrical and power qualityvariables can be simultaneously input into building management systems via pulsed,analogue or digital communication options. Status may also be monitored via a PCthrough a software package.
Alternatively, an optional menu driven display unit can be used to configure and monitorup to 32 measured parameters including three-phase voltage and current and systemwatts, VAr, VA, power factor, energy and total harmonic distortion. The Integra Displayunit panel can be permanently mounted next to the transducer or simply connected attimes when configuration, adjustment and/or status information is required.
Accuracy
Integra transducers utilize true RMS measurement techniques up to the 31stharmonic, providing <0.2% accuracy. An exceptional tolerance to high harmonicfrequencies is achieved from the robust frequency detection method, which is able tolock the fundamental frequency onto any phase. High integrity measurements arepossible where the system approximates CT current in the absence of voltage signals.
Dimensions
Integra 1560 DIN Rail Mounted Transducer
Measurement and Communication
Up to 50 electrical and power qualityparameters can be measured and inputinto building management systems orviewed through the softwareconfiguration package via a PC.
Volts L1-N, L2-N, L3-NVolts L1-L2, L2-L3, L3-L1System volts L-N (average)System volts L-L (average)Current line 1, 2 and 3System current (average)Current sumCurrent demandCurrent maximum demandNeutral currentSystem frequencyWatts 1, 2 and 3System watts (sum)Watts demand (import)Watts maximum demand (import)Watt-hours (import)VAr 1, 2 and 3System VAr (sum)VAr-hours (import)VA 1, 2 and 3System VA (sum)Power factor 1, 2 and 3System power factor (average)Phase angle 1, 2 and 3System phase angle (average)THD volts 1, 2 and 3THD system volts (mean)THD amps 1, 2 and 3THD system amps (mean)
14
Ordering code key Product configuration
INT-1561-*-5-**-option-*** Integra 1560 1-phase 5A CT input, DIN railINT-1562-*-5-**-option-*** Integra 1560 1-phase 3-wire 5A CT input, DIN railINT-1563-*-5-**-option-*** Integra 1560 3-phase 3-wire 5A CT input, DIN railINT-1564-*-5-**-option-*** Integra 1560 3-phase 4-wire 5A CT input, DIN railINT-1581-*-5-**-option-*** Integra 1580 1-phase 5A CT input, base mountINT-1582-*-5-**-option-*** Integra 1580 1-phase 3-wire 5A CT input, base mountINT-1583-*-5-**-option-*** Integra 1580 3-phase 3-wire 5A CT input, base mountINT-1584-*-5-**-option-*** Integra 1580 3-phase 4-wire 5A CT input, base mount*Input voltage suffix
L 57.7–139V L-N 1561 and 1581114–278V L-L (57.7–139V L-N) 1562 and 1582100–240V L-L (57.7–139V L-N) 1563,4 and 1583,4
M 140–277V L-N 1561 and 1581279–480V L-L (140–240V L-N) 1562 and 1582241–480V L-L (140–277V L-N) 1563,4 and 1583,4
**Auxiliary supply suffixL 12–48V dcM 100–250V ac/dc
Communications
010 1011 1 1012 1 2013 1 3014 1 4020 2021 2 1022 2 2023 2 3024 2 4040 1 1110 1 1111 1 1 1112 1 1 2113 1 1 3114 1 1 4120 1 2121 1 2 1122 1 2 2123 1 2 3124 1 2 4210 2 1211 2 1 1212 2 1 2220 2 2221 2 2 1222 2 2 2410 4 1411 4 1 1412 4 1 2420 4 2421 4 2 1422 4 2 2610 6 1611 6 1 1612 6 1 2620 6 2621 6 2 1622 6 2 2***Analogue output
range0 No output1 0-20 mA, 10V compliance (user configurable as
4-20 mA)Available for up to 3 output channels only
2 0-1 mA, 10V compliance3 -1/0/+1 mA, 10V compliance4 0-5 mA, 10V compliance6 0-10 mA, 10V compliance
Ordering Codes
Puls
ed/re
lay
outp
uts
RS4
85 in
terf
ace
Mod
bus®
orJo
hnso
n C
ontr
ols
Met
asys
NII
Lonw
orks
inte
rfac
e
Ana
logu
e ou
tput
s
1560 - Three-phase four-wire
Unbalanced Load
1560 - Three-phase three-wire
Unbalanced Load
Modbus® is a trademark of Schneider Automation IncLonworks is a trademark of Echelon Corporation. Profibus is a trademark of PROFIBUS Nutzerorganisation e.v
15
AC Current Average Sensing
AC Voltage Average Sensing
Frequency Transducer
Watts Power Transducers
Other Transducers avaliable consult Paladin and Integra 1560/1580 literature.*Please specify, voltage and current transformer ratios and kW range. e.g. 11KV/110V,200/5A, 0/4MW.
Description – CT and Watts Code
Rating to be specified CROMPTON
upon ordering
3-phase 3-wire balanced load 256-TWLW-QZFA-C5-VN5A + 400V-0/1mA self powered3-phase 3-wire balanced load 256-TWLW-QZHG-C5-VN5A + 400V-4/20mA self powered3-phase 3-wire unbalanced load 256-TWMW-QZFA-C5-VN5A + 400V-0/1mA self powered3-phase 3-wire unbalanced load 256-TWMW-QZHG-C5-VN5A + 400V-4/20mA self powered3-phase 4-wire balanced load 256-TWHW-VRFA-C5-VN5A + 400V-0/1mA self powered3-phase 4-wire balanced load 256-TWHW-VRHG-C5-VN5A + 400V-4/20mA self powered3-phase 4-wire unbalanced load 256-TWNW-VRFA-C5-VN5A + 400V-0/1mA self powered3-phase 4-wire unbalanced load 256-TWNW-VRHG-C5-VN5A + 400V-4/20mA self powered
Description Code
CROMPTON
1-phase 5A-0/20mA 5A CT 253-TAAW-LSHF-C5input. Self powered1-phase 5A-4/20mA 5A CT 253-TALW-LSHG-C5-AMinput. aux 230V/50Hz1-phase 5A4/20mA 5A CT 253-TALW-LSHG-C5-AVinput. aux 400V/50Hz
Description Code
CROMPTON
1-phase 230V-0/20mA 253-TVAW-RQHF-C5 self powered 1-phase 400V-0/20mA 253-TVAW-SCHF-C5self powered 1-phase 230V-4/20mA 253-TVLW-RQHG-C5-AMaux 230V/50Hz1-phase 230V-4/20mA 253-TVLW-RQHG-C5-AVaux 400V/50Hz1-phase 400V- 4/20mA 253-TVLW-SCHG-C5-AMaux 230V/50Hz1-phase 400V-4/20mA 253-TVLW-SCHG-C5-AVaux 400V/50Hz
Description Code
CROMPTON
230V-0/20mA 45/55Hz 253-THZW-RQHF-AGself powered230V-4/20mA 45/55Hz 253-THZW-RQHG-AGself powered
An extensive range of Class 0.5 transducers providing measurement,isolation and conversion of electrical parameters into industry standarddc output signals. The range offers protection against high voltage andoverload and resistance to vibration in harsh electrical environments.Transducers offer multiple analogue outputs in a single housing andindividual measurement of most electrical parameters.
Paladin Transducers 250 series
16
Connections
253-TAA 253-TAL
253-TVA/253-THZ 253-TVL
256-TWL Three-wire System 256-TWH Four-wire System
Balanced Balanced
256-TWM Three-wire System 256-TWN Four-wire System
Unbalanced Unbalanced
Dimensions
A
70mm
35mm
REAR VIEW SHOWING PANELMOUNTING HOLES
B
50mm(M4)
60mm(M5)
70mm
RELEASE CLIP
112
Model A B
253 75 60256-T* 150 135
17
Protector Relays
AC Current Relays – Aux. 230 AC with Adjustable Time Delay (0-10 seconds)
AC Voltage Relays with Adjustable Differential
AC Voltage Relay with Adjustable Time Delay (0-10 seconds)
Frequency Relay
Phase Sequence and Phase Failure Relay
Description Code
CROMPTON
1-phase 5A CT input, 50/60Hz, 252-PAUW-LSBX-C7-AM-D1-EBunder-current 40-120%. aux 230V ac1-phase 5A CT input, 50/60Hz, 252-PAOW-LSBX-C7-AM-D1-EAover-current 40-120%. aux 230V ac1-phase 5A CT input, 50/60Hz, 253-PADW-LSBX-C7-AM-D1-ECunder/over-current 40-120%. aux 230V ac3-phase 3 or 4-wire 5A CT input, 253-PAVW-LSBX-C7-AM-D1-EB50/60Hz, under-current 40-120%. aux 230V ac3-phase 3 or 4-wire 5A CT input, 253-PAPW-LSBX-C7-AM-D1-EA50/60Hz, over-current 40-120%. aux 230V ac
Description Code
CROMPTON
1-phase 230V 50Hz 252-PVUW-RQBX-C5-EBunder-voltage 75-100%1-phase 230V 50Hz 252-PVOW-RQBX-C5-EAover-voltage 100-125%1-phase 230V 50Hz 253-PVBW-RQBX-C5-ECunder/over-voltage 3-phase 3-wire 400V L-L 50Hz 253-PVMW-SCBX-C5-ECunder/over-voltage3-phase 4-wire 230V L-N 50Hz 253-PVEW-RQBX-C5-ECunder/over-voltage
Description Code
CROMPTON
3-phase 3-wire 400V L-L 50Hz 252-PVJW-SCBX-C5-EB-T1under-voltage 75-100%3-phase 3-wire 400V L-L 50Hz 252-PVCW-SCBX-C5-EA-T1over-voltage 100-125%3-phase 4-wire 230V L-N 50Hz 252-PVXW-RQBX-C5-EB-T1under-voltage 75-100%3-phase 4-wire 230V L-N 50Hz 252-PVSW-RQBX-C5-EA-T1over-voltage 100-125%
Description Code
CROMPTON
3-phase 3 or 4-wire 400V L-L phase 252-PVRW-SCBX-C5sequence and under-voltage 80%
Description Code
CROMPTON
1-phase 2-wire 230V L-L or L-N 252-PHUW-RQBX-C5-EBunder-frequency (nominal 50Hz)1-phase 2-wire 230V L-L or L-N 252-PHOW-RQBX-C5-EAover-frequency (nominal 50Hz)1-phase 2-wire 230V L-L or L-N 253-PHDW-RQBX-C5-ECunder/over-frequency (nominal 50Hz)1-phase 2-wire 400V L-L or L-N 253-PHDW-SCBX-C5-ECunder/over-frequency (nominal 50Hz)
An extensive range of electronic control products providing continuousmonitoring and protection of any electrical parameter. When the monitoredparameter deviates from the desired set-point limit, the relay will operate toprevent damage to the power asset. Designed to suit a wide variety ofapplications the range offers both traditional and technologically advancedproducts, from single parameter units through to multifunctionalmicroprocessor based protection relays.
18
Reverse Power (Current)
Input1
Input2
Input3
SupplyRelayContact Set 1
RelayContact Set 2
Contact Set 1 Contact Set 2
Input
Under RelayContact Set 1
Over RelayContact Set 1
Under RelayContact Set 2
Over RelayContact Set 2
Input
Relay
Input VoltsSingle-phase3-phase 4-wire
3-phase 3-wire
Contact Set 1 Contact Set 2Output Relay
Input Amps
Description Code
CROMPTON
1 or 3-phase 4-wire 230V L-N, 256-PASW-LSBX-RQ-C5-EA5A, 50Hz. Reverse power protection 2-20%3-phase 3-wire 400V L-L, 5A, 50Hz 256-PATW-LSBX-SC-C5-EAReverse power protection 2-20%
55mm (2.2”)70
mm
(2.8
”)
35m
m (1
.37”
)
112mm (4.4”)
RELEASE CLIP
55mm (2.2”)
35m
m (1
.37”
)
17.5mm(0.68”) 35mm
(1.37”) 15.5
mm
(0.6
”)12
mm
(0.5
”)
2 HOLESØ 4.1”
75mm (2.9”)
70m
m (2
.8”)
112.5mm (4.4”)
35m
m
(1.3
7”)
RELEASE CLIP
60mm (2.4”)
2 FIXING HOLE'A' TO SUIT M4
2 FIXING HOLE'A' TO SUIT M4
50m
m (1
.96”
)60
mm
(2.3
6”)
150mm (5.9”)
70m
m (2
.8”)
112.5mm (4.4”)
135mm (5.3”)
2 FIXING HOLE'A' TO SUIT M4
2 FIXING HOLE'A' TO SUIT M4
RELEASE CLIP
Dimensions
Connections
253-PAP
253-PVM
252-PVJ
252-PVR
253-PHD
256-PAS/256-PAT
256-PAQ/256-PAR
Input
Input
Contact Set 1 Contact Set 2
Input Aux supplyWhen required
Relay
Format 256
Format 253
Format 252
19
Earth Leakage Relays
Earth Leakage Relays – Pre-Alarm Option (SPCO)
Dimensions to DIN 43880
• Monitors and detects potentially dangerous earth leakage currents• Used in conjunction with core balanced CTs• Precision digital settings
• 10 x current trip levels 30mA–10A• 16 x time delays 0–10 seconds
• LED Bar-graph display• 0/1mA analogue output• User selectable energise or de-energise on trip link• Double-pole change over relay (standard)• Single-pole pre-alarm option
110.0mm 4.32"
73.0mm 2.87"
33.0mm 1.3"
48.0mm 1.89"
71.0mm2.79"
62.5
mm
2.46
"
90.5
mm
3.56
"
46.0
mm
1.87
"
Description Code
CROMPTON
24-48 volts ac 373-ELRW-CBC5-A2-ST100-250 volts ac and dc 373-ELRW-CBC5-A3-ST
Description Code
CROMPTON
24-48 volts ac 373-ELRW-CBC5-A2-PA100-250 volts ac and dc 373-ELRW-CBC5-A3-PA
Residual current devices are used to detect potentially dangerous earthfault currents before damage is caused. The 373-ELR earth leakageprotection relay allows the fault current to be continuously monitored andcompared with the user selectable leakage level. Should the leakageexceed this level, the relay will trip to indicate a fault condition. With avery fast response time of under 40ms, the supply can be disconnectedbefore serious damage can occur.
Remoteresetswitch
FusedAuxiliarysupply
The equipment grounding conductormust bypass the CT
CommissioningMeter
Link to energiseon trip
GND
Relay 1 Relay 2
Connections
151 152
20
Core Balance CTs
Aperture
Dim E Dim A Dim B Dim C Dim D Catalogue no.
35mm 100mm 79mm 26mm 48.5mm CBT-94F-03570mm 130mm 110mm 32mm 66mm CBT-94F-070105mm 170mm 146mm 38mm 94mm CBT-94F-105140mm 220mm 196mm 49mm 123mm CBT-94F-140210mm 299mm 284mm 69mm 161mm CBT-94F-210300mm 400mm 380mm – – CBT-94F-300
• For use with model 373-ELR earth leakage relay• Leakage measurement range 0 to 10A• Toroidal CT• UL94V-0 flame retardant plastic case• Terminal cover• Steel mounting feet
A
øE
B
33
DC
46
Product Codes and Dimensions
Earth Leakage Relays – Core Balanced Current Transformers
Description Code
CROMPTON
Aperture diameter 35mm CBT-94F-035Aperture diameter 70mm CBT-94F-070Aperture diameter 105mm CBT-94F-105Aperture diameter 140mm CBT-94F-140Aperture diameter 210mm CBT-94F-210Aperture diameter 300mm CBT-94F-300
The CBT-94F series of core balanced current transformers are exclusivelyfor use with our 373-ELR earth leakage protection relay. The extremelysensitive toroidal core and secondary winding are encapsulated by a selfextinguishing case providing excellent mechanical strength, protectionfrom damage and electrical insulation.
21
High quality analogue instruments designed to measure an extensiverange of electrical and electronic parameters. This comprehensive rangeoffers DIN instruments, ANSI switchboard meters, panel indicators,sealed and ruggedised instruments and complementary selectorswitches for line-to-line and line-to-neutral readings. Instruments areprecision engineered and robust in design, ensuring accuratemeasurement and display in the most demanding of environments.All instruments are available in a range of styles, sizes and specificationsto meet the exacting needs of your industry.
Analogue Instruments
Contents Page
DIN Panel Meter with Selector Switch 22
AC Ammeters 23 – 28
AC Voltmeters 29
Frequency Meters 30
Hour Run Meters 31
DC Ammeters 32 – 34
DC Voltmeters 35
22
Product Codes – AC Ammeters with Selector Switch
**Insert application CT primary value.
**Insert application able, e.g. 15kV/110V VT, VT primary and secondary value.
Code Case Full Scale Switch Notation
Size Deflection
E243-02E-G-LS**-C7-AMP3 72mm 0/5A ac OFF L1 L2 L3E244-02E-G-LS**-C7-AMP3 96mm 0/5A ac OFF L1 L2 L3E243-022E-G-LS**-C7-AMP3 72mm 0/5/10A ac OFF L1 L2 L3E244-022E-G-LS**-C7-AMP3 96mm 0/5/10A ac OFF L1 L2 L3E243-02E-G-LA**-C7-AMP3 72mm 0/1A ac OFF L1 L2 L3E244-02E-G-LA**-C7-AMP3 96mm 0/1A ac OFF L1 L2 L3E243-022E-G-LA**-C7-AMP3 72mm 0/1/2A ac OFF L1 L2 L3E244-022E-G-LA**-C7-AMP3 96mm 0/1/2A ac OFF L1 L2 L3
Product Codes – AC Voltmeters with Selector Switch
Dimensions
72DIN Models
96DIN Models
Code Case Full Scale Switch Notation 3-
Size Deflection phase
E243-02Q-G- 72mm 0/120V ac 0FF L1L2 L2L3 3WPM**-C7-SW6 L3L1-C7-SW6E243-02Q-G 72mm 0/150V ac 0FF L1L2 L2L3 3WPZ**-C7-SW6 L3L1-C7-SW6E243-02Q-G-PZ 72mm 0/150V ac 0FF L1L2 L2L3 3WPZ-C7-SW6 L3L1-C7-SW6E243-02Q-G-RX- 72mm 0/300V ac 0FF L1L2 L2L3 3WRX-C7-SW6 L3L1-C7-SW6E243-02Q-G- 72mm 0/500V ac L1L3 L1L2 L2L3-C7 4WSF-SF-C7-SW6 -SW3 L3N L2N L1NE243-02Q-G- 72mm 0/600V ac L1L3 L1L2 L2L3-C7 4WSJ-SJ-C7-SW6 -SW3 L3N L2N L1NE244-02Q-G 96mm 0/150V ac 0FF L1L2 L2L3 3W-PZ**-C7-SW6 L3L1-C7-SW6E244-02Q-G- 96mm 0/150V ac 0FF L1L2 L2L3 3WPZ-PZ-C7-SW6 L3L1-C7-SW6E244-02Q-G- 96mm 0/300V ac 0FF L1L2 L2L3 3WRX-RX-C7-SW6 L3L1-C7-SW6E244-02Q-G- 96mm 0/500V ac L1L3 L1L2 L2L3-C7 4WSF-SF-C7-SW6 -SW3 L3N L2N L1NE244-02Q-G- 96mm 0/600V ac L1L3 L1L2 L2L3-C7 4WSF-S3-C7-SW6 -SW3 L3N L2N L1N
Connections
AC Ammeters with Selector Switch
AC Voltmeters three-phase three-wire
AC Voltmeters three-phase four-wire
DIN Panel Meter with Selector Switch
Panel
Cut-Out
Panel
Cut-Out
23
Description Code
CROMPTON
5A CT operated, scaled 0-1A. 50/60Hz E242-75A-G-LS-LA-C75A CT operated, scaled 0-2A. 50/60Hz E242-75A-G-LS-LE-C75A CT operated, scaled 0-2.5A. 50/60Hz E242-75A-G-LS-LF-C75A CT operated, scaled 0-5A. 50/60Hz E242-75A-G-LS-LS-C75A CT operated, scaled 0-7.5A. 50/60Hz E242-75A-G-LS-MF-C75A CT operated, scaled 0-10A. 50/60Hz E242-75A-G-LS-MT-C75A CT operated, scaled 0-15A. 50/60Hz E242-75A-G-LS-ND-C75A CT operated, scaled 0-20A. 50/60Hz E242-75A-G-LS-NG-C75A CT operated, scaled 0-25A. 50/60Hz E242-75A-G-LS-NJ-C75A CT operated, scaled 0-30A. 50/60Hz E242-75A-G-LS-NL-C75A CT operated, scaled 0-40A. 50/60Hz E242-75A-G-LS-NP-C75A CT operated, scaled 0-50A. 50/60Hz E242-75A-G-LS-NT-C75A CT operated, scaled 0-60A. 50/60Hz E242-75A-G-LS-NW-C75A CT operated, scaled 0-75A. 50/60Hz E242-75A-G-LS-PB-C75A CT operated, scaled 0-80A. 50/60Hz E242-75A-G-LS-PD-C75A CT operated, scaled 0-100A. 50/60Hz E242-75A-G-LS-PK-C75A CT operated, scaled 0-120A. 50/60Hz E242-75A-G-LS-PQ-C75A CT operated, scaled 0-125A. 50/60Hz E242-75A-G-LS-PS-C75A CT operated, scaled 0-150A. 50/60Hz E242-75A-G-LS-PZ-C75A CT operated, scaled 0-200A. 50/60Hz E242-75A-G-LS-RL-C75A CT operated, scaled 0-250A. 50/60Hz E242-75A-G-LS-RS-C75A CT operated, scaled 0-300A. 50/60Hz E242-75A-G-LS-RX-C75A CT operated, scaled 0-400A. 50/60Hz E242-75A-G-LS-SC-C75A CT operated, scaled 0-500A. 50/60Hz E242-75A-G-LS-SF-C75A CT operated, scaled 0-600A. 50/60Hz E242-75A-G-LS-SJ-C75A CT operated, scaled 0-750A. 50/60Hz E242-75A-G-LS-SM-C75A CT operated, scaled 0-800A. 50/60Hz E242-75A-G-LS-SN-C75A CT operated, scaled 0-1000A. 50/60Hz E242-75A-G-LS-SS-C75A CT operated, scaled 0-1200A. 50/60Hz E242-75A-G-LS-A9-C75A CT operated, scaled 0-1250A. 50/60Hz E242-75A-G-LS-A1-C75A CT operated, scaled 0-1500A. 50/60Hz E242-75A-G-LS-B2-C75A CT operated, scaled 0-1600A. 50/60Hz E242-75A-G-LS-AE-C75A CT operated, scaled 0-2000A. 50/60Hz E242-75A-G-LS-A3-C75A CT operated, scaled 0-2500A. 50/60Hz E242-75A-G-LS-A4-C75A CT operated, scaled 0-3000A. 50/60Hz E242-75A-G-LS-A5-C7
DIN48 Moving Iron Shortscale AC Ammeters CT Operated
Analogue Indicators –
AC Ammeters 90°, 48mm
Description Code
CROMPTON
1A direct connected. Scaled 0-1A. 50/60Hz E242-75A-G-LA-LA-C72.5A direct connected. Scaled 0-2.5A. 50/60Hz E242-75A-G-LF-LF-C75A direct connected. Scaled 0-5A. 50/60Hz E242-75A-G-LS-LS-C77.5A direct connected. Scaled 0-7.5A. 50/60Hz E242-75A-G-MF-MF-C710A direct connected. Scaled 0-10A. 50/60Hz E242-75A-G-MT-MT-C715A direct connected. Scaled 0-15A. 50/60Hz E242-75A-G-ND-ND-C720A direct connected. Scaled 0-20A. 50/60Hz E242-75A-G-NG-NG-C725A direct connected. Scaled 0-25A. 50/60Hz E242-75A-G-NJ-NJ-C730A direct connected. Scaled 0-30A. 50/60Hz E242-75A-G-NL-NL-C740A direct connected. Scaled 0-40A. 50/60Hz E242-75A-G-NP-NP-C7
DIN48 Moving Iron Shortscale AC Ammeters Direct Connected
Description Code
CROMPTON
1A direct connected. Scaled 0-1A. 50/60Hz E242-75A-G-LA-LA-C72.5A direct connected. Scaled 0-2.5A. 50/60Hz E242-75A-G-LF-LF-C75A direct connected. Scaled 0-5A. 50/60Hz E242-75A-G-LS-LS-C77.5A direct connected. Scaled 0-7.5A. 50/60Hz E242-75A-G-MF-MF-C710A direct connected. Scaled 0-10A. 50/60Hz E242-75A-G-MT-MT-C715A direct connected. Scaled 0-15A. 50/60Hz E242-75A-G-ND-ND-C720A direct connected. Scaled 0-20A. 50/60Hz E242-75A-G-NG-NG-C725A direct connected. Scaled 0-25A. 50/60Hz E242-75A-G-NJ-NJ-C730A direct connected. Scaled 0-30A. 50/60Hz E242-75A-G-NL-NL-C740A direct connected. Scaled 0-40A. 50/60Hz E242-75A-G-NP-NP-C7
DIN48 Moving Iron Shortscale AC Ammeters Direct Connected
Dimensions
Max. panel thickness = 40mm
Dimensions
Moving coil measuring range
6-60A C=67mm >60A C=78mm
Moving coil measuring range
0-30A C=64mm >30A C=67mm
D A B
48 x 48 45 x 45 472 x 72 68 x 68 496 x 96 92 x 92 4
144 x 144 135 x 135 4
A B
24
DIN72 Moving Iron Shortscale AC Ammeters Direct Connected
Description Code
CROMPTON
5A CT operated, scaled 0-1A. 50/60Hz E243-02A-G-LS-LA-C75A CT operated, scaled 0-2A. 50/60Hz E243-02A-G-LS-LE-C75A CT operated, scaled 0-2.5A. 50/60Hz E243-02A-G-LS-LF-C75A CT operated, scaled 0-5A. 50/60Hz E243-02A-G-LS-LS-C75A CT operated, scaled 0-7.5A. 50/60Hz E243-02A-G-LS-MF-C75A CT operated, scaled 0-10A. 50/60Hz E243-02A-G-LS-MT-C75A CT operated, scaled 0-15A. 50/60Hz E243-02A-G-LS-ND-C75A CT operated, scaled 0-20A. 50/60Hz E243-02A-G-LS-NG-C75A CT operated, scaled 0-25A. 50/60Hz E243-02A-G-LS-NJ-C75A CT operated, scaled 0-30A. 50/60Hz E243-02A-G-LS-NL-C75A CT operated, scaled 0-40A. 50/60Hz E243-02A-G-LS-NP-C75A CT operated, scaled 0-50A. 50/60Hz E243-02A-G-LS-NT-C75A CT operated, scaled 0-60A. 50/60Hz E243-02A-G-LS-NW-C75A CT operated, scaled 0-75A. 50/60Hz E243-02A-G-LS-PB-C75A CT operated, scaled 0-80A. 50/60Hz E243-02A-G-LS-PD-C75A CT operated, scaled 0-100A. 50/60Hz E243-02A-G-LS-PK-C75A CT operated, scaled 0-120A. 50/60Hz E243-02A-G-LS-PQ-C75A CT operated, scaled 0-125A 50/60Hz E243-02A-G-LS-PS-C75A CT operated, scaled 0-150A. 50/60Hz E243-02A-G-LS-PZ-C75A CT operated, scaled 0-200A. 50/60Hz E243-02A-G-LS-RL-C75A CT operated, scaled 0-250A. 50/60Hz E243-02A-G-LS-RS-C75A CT operated, scaled 0-300A. 50/60Hz E243-02A-G-LS-RX-C75A CT operated, scaled 0-400A. 50/60Hz E243-02A-G-LS-SC-C75A CT operated, scaled 0-500A. 50/60Hz E243-02A-G-LS-SF-C75A CT operated, scaled 0-600A. 50/60Hz E243-02A-G-LS-SJ-C75A CT operated, scaled 0-750A. 50/60Hz E243-02A-G-LS-SM-C75A CT operated, scaled 0-800A. 50/60Hz E243-02A-G-LS-SN-C75A CT operated, scaled 0-1000A. 50/60Hz E243-02A-G-LS-SS-C75A CT operated, scaled 0-1200A. 50/60Hz E243-02A-G-LS-A9-C75A CT operated, scaled 0-1250A. 50/60Hz E243-02A-G-LS-A1-C75A CT operated, scaled 0-1500A. 50/60Hz E243-02A-G-LS-B2-C75A CT operated, scaled 0-1600A. 50/60Hz E243-02A-G-LS-AE-C75A CT operated, scaled 0-2000A. 50/60Hz E243-02A-G-LS-A3-C75A CT operated, scaled 0-2500A. 50/60Hz E243-02A-G-LS-A4-C75A CT operated, scaled 0-3000A. 50/60Hz E243-02A-G-LS-A5-C7
Description Code
CROMPTON
0/1A direct connected, scaled 0-1A. E243-02A-G-LA-LA-C750/60Hz2.5A direct connected, scaled 0-2.5A. E243-02A-G-LF-LF-C750/60Hz5A direct connected, scaled 0-5A. E243-02A-G-LS-LS-C750/60Hz7.5A direct connected, scaled 0-7.5A. E243-02A-G-MF-MF-C750/60Hz10A direct connected, scaled 0-10A. E243-02A-G-MT-MT-C750/60Hz15A direct connected, scaled 0-15A. E243-02A-G-ND-ND-C750/60Hz20A direct connected, scaled 0-20A. E243-02A-G-NG-NG-C750/60Hz25A direct connected, scaled 0-25A. E243-02A-G-NJ-NJ-C750/60Hz30A direct connected, scaled 0-30A. E243-02A-G-NL-NL-C750/60Hz40A direct connected, scaled 0-40A. E243-02A-G-NP-NP-C750/60Hz50A direct connected, scaled 0-50A. E243-02A-G-NT-NT-C750/60Hz60A direct connected, scaled 0-60A. E243-02A-G-NW-NW-C750/60Hz
DIN72 Moving from Shortscale AC Ammeters CT Operated
Analogue Indicators –
AC Ammeters 90°, 72mm
25
Description Code
CROMPTON
0-1A direct connected, scaled 0-1A. 50/60Hz E244-02A-G-LA-LA-C72.5A direct connected, scaled 0-2.5A. 50/60Hz E244-02A-G-LF-LF-C75A direct connected, scaled 0-5A. 50/60Hz E244-02A-G-LS-LS-C77.5A direct connected, scaled 0-7.5A. 50/60Hz E244-02A-G-MF-MF-C710A direct connected, scaled 0-10A. 50/60Hz E244-02A-G-MT-MT-C715A direct connected, scaled 0-15A. 50/60Hz E244-02A-G-ND-ND-C720A direct connected, scaled 0-20A. 50/60Hz E244-02A-G-NG-NG-C725A direct connected, scaled 0-25A. 50/60Hz E244-02A-G-NJ-NJ-C730A direct connected, scaled 0-30A. 50/60Hz E244-02A-G-NL-NL-C740A direct connected, scaled 0-40A. 50/60Hz E244-02A-G-NP-NP-C750A direct connected, scaled 0-50A. 50/60Hz E244-02A-G-NT-NT-C760A direct connected, scaled 0-60A. 50/60Hz E244-02A-G-NW-NW-C7
Description Code
CROMPTON
5A CT operated, scaled 0-1A. 50/60Hz E244-02A-G-LS-LA-C75A CT operated, scaled 0-2A. 50/60Hz E244-02A-G-LS-LE-C75A CT operated, scaled 0-2.5A. 50/60Hz E244-02A-G-LS-LF-C75A CT operated, scaled 0-5A. 50/60Hz E244-02A-G-LS-LS-C75A CT operated, scaled 0-7.5A. 50/60Hz E244-02A-G-LS-MF-C75A CT operated, scaled 0-10A. 50/60Hz E244-02A-G-LS-MT-C75A CT operated, scaled 0-15A. 50/60Hz E244-02A-G-LS-ND-C75A CT operated, scaled 0-20A. 50/60Hz E244-02A-G-LS-NG-C75A CT operated, scaled 0-25A. 50/60Hz E244-02A-G-LS-NJ-C75A CT operated, scaled 0-30A. 50/60Hz E244-02A-G-LS-NL-C75A CT operated, scaled 0-40A. 50/60Hz E244-02A-G-LS-NP-C75A CT operated, scaled 0-50A. 50/60Hz E244-02A-G-LS-NT-C75A CT operated, scaled 0-60A. 50/60Hz E244-02A-G-LS-NW-C75A CT operated, scaled 0-75A. 50/60Hz E244-02A-G-LS-PB-C75A CT operated, scaled 0-80A. 50/60Hz E244-02A-G-LS-PD-C75A CT operated, scaled 0-100A. 50/60Hz E244-02A-G-LS-PK-C75A CT operated, scaled 0-120A. 50/60Hz E244-02A-G-LS-PQ-C75A CT operated, scaled 0-125A. 50/60Hz E244-02A-G-LS-PS-C75A CT operated, scaled 0-150A. 50/60Hz E244-02A-G-LS-PZ-C75A CT operated, scaled 0-200A. 50/60Hz E244-02A-G-LS-RL-C75A CT operated, scaled 0-250A. 50/60Hz E244-02A-G-LS-RS-C75A CT operated, scaled 0-300A. 50/60Hz E244-02A-G-LS-RX-C75A CT operated, scaled 0-400A. 50/60Hz E244-02A-G-LS-SC-C75A CT operated, scaled 0-500A. 50/60Hz E244-02A-G-LS-SF-C75A CT operated, scaled 0-600A. 50/60Hz E244-02A-G-LS-SJ-C75A CT operated, scaled 0-750A. 50/60Hz E244-02A-G-LS-SM-C75A CT operated, scaled 0-800A. 50/60Hz E244-02A-G-LS-SN-C75A CT operated, scaled 0-1000A. 50/60Hz E244-02A-G-LS-SS-C75A CT operated, scaled 0-1200A. 50/60Hz E244-02A-G-LS-A9-C75A CT operated, scaled 0-1250A. 50/60Hz E244-02A-G-LS-A1-C75A CT operated, scaled 0-1500A. 50/60Hz E244-02A-G-LS-B2-C75A CT operated, scaled 0-1600A. 50/60Hz E244-02A-G-LS-AE-C75A CT operated, scaled 0-2000A. 50/60Hz E244-02A-G-LS-A3-C75A CT operated, scaled 0-2500A. 50/60Hz E244-02A-G-LS-A4-C75A CT operated, scaled 0-3000A. 50/60Hz E244-02A-G-LS-A5-C7
Analogue Indicators –
AC Ammeters 90°, 96mm
DIN96 AC Ammeters Direct Connected
DIN96 AC Ammeters Connect via CT X/5A with Fixed Dial Plate
Normal Scaling
26
Analogue Indicators –
AC Ammeters 90°, 48mm
Description Code
CROMPTON
1A direct connected, scaled 0-1A. 50/60Hz E242-756A-G-LA-LA-C72.5A direct connected, scaled 0-2.5A. 50/60Hz E242-756A-G-LF-LF-C75A direct connected, scaled 0-5A. 50/60Hz E242-756A-G-LS-LS-C77.5A direct connected, scaled 0-7.5A. 50/60Hz E242-756A-G-MF-MF-C710A direct connected, scaled 0-10A. 50/60Hz E242-756A-G-MT-MT-C715A direct connected, scaled 0-15A. 50/60Hz E242-756A-G-ND-ND-C720A direct connected, scaled 0-20A. 50/60Hz E242-756A-G-NG-NG-C725A direct connected, scaled 0-25A. 50/60Hz E242-756A-G-NJ-NJ-C730A direct connected, scaled 0-30A. 50/60Hz E242-756A-G-NL-NL-C740A direct connected, scaled 0-40A. 50/60Hz E242-756A-G-NP-NP-C7
Description Code
CROMPTON
5A CT operated, scaled 0-1/6A 50/60Hz E242-756A-G-LS-LA-C75A CT operated, scaled 0-2/12A 50/60Hz E242-756A-G-LS-LE-C75A CT operated, scaled 0-2.5/15A 50/60Hz E242-756A-G-LS-LF-C75A CT operated, scaled 0-5/30A 50/60Hz E242-756A-G-LS-LS-C75A CT operated, scaled 0-7.5/45A 50/60Hz E242-756A-G-LS-MF-C75A CT operated, scaled 0-10/60A 50/60Hz E242-756A-G-LS-MT-C75A CT operated, scaled 0-15/90A 50/60Hz E242-756A-G-LS-ND-C75A CT operated, scaled 0-20/120A 50/60Hz E242-756A-G-LS-NG-C75A CT operated, scaled 0-25/150A 50/60Hz E242-756A-G-LS-NJ-C75A CT operated, scaled 0-30/180A 50/60Hz E242-756A-G-LS-NL-C75A CT operated, scaled 0-40/240A 50/60Hz E242-756A-G-LS-NP-C75A CT operated, scaled 0-50/300A 50/60Hz E242-756A-G-LS-NT-C75A CT operated, scaled 0-60/360A 50/60Hz E242-756A-G-LS-NW-C75A CT operated, scaled 0-75/450A 50/60Hz E242-756A-G-LS-PB-C75A CT operated, scaled 0-80/480A 50/60Hz E242-756A-G-LS-PD-C75A CT operated, scaled 0-100/600A 50/60Hz E242-756A-G-LS-PK-C75A CT operated, scaled 0-120/720A 50/60Hz E242-756A-G-LS-PQ-C75A CT operated, scaled 0-125/750A 50/60Hz E242-756A-G-LS-PS-C75A CT operated, scaled 0-150/900A 50/60Hz E242-756A-G-LS-PZ-C75A CT operated, scaled 0-200/1200A 50/60Hz E242-756A-G-LS-RL-C75A CT operated, scaled 0-250/1500A 50/60Hz E242-756A-G-LS-RS-C75A CT operated, scaled 0-300/1800A 50/60Hz E242-756A-G-LS-RX-C75A CT operated, scaled 0-400/2400A 50/60Hz E242-756A-G-LS-SC-C75A CT operated, scaled 0-500/3000A 50/60Hz E242-756A-G-LS-SF-C75A CT operated, scaled 0-600/3600A 50/60Hz E242-756A-G-LS-SJ-C75A CT operated, scaled 0-750/4500A 50/60Hz E242-756A-G-LS-SM-C75A CT operated, scaled 0-800/4800A 50/60Hz E242-756A-G-LS-SN-C75A CT operated, scaled 0-1000/6000A 50/60Hz E242-756A-G-LS-SS-C75A CT operated, scaled 0-1200/7200A 50/60Hz E242-756A-G-LS-ZW-C75A CT operated, scaled 0-1250/7500A 50/60Hz E242-756A-G-LS-BF-C75A CT operated, scaled 0-1500/9000A 50/60Hz E242-756A-G-LS-A1-C75A CT operated, scaled 0-1600/9600A 50/60Hz E242-756A-G-LS-Z7-C75A CT operated, scaled 0-2/12KA 50/60Hz E242-756A-G-LS-TM-C75A CT operated, scaled 0-2.5/15KA 50/60Hz E242-756A-G-LS-TU-C75A CT operated, scaled 0-3/18KA 50/60Hz E242-756A-G-LS-UA-C7
DIN48 Moving Iron Shortscale AC Ammeters x 6 Overload
Direct Connected
DIN48 Moving Iron Shortscale AC Ammeters x 6 Overload CT Operated
27
Analogue Indicators –
AC Ammeters 90°, 72mm
Description Code
CROMPTON
0/1A direct connected, scaled 0-1/6A. 50/60Hz E243-026A-G-LA-LA-C72.5A direct connected, scaled 0-2.5/15A. 50/60Hz E243-026A-G-LF-LF-C75A direct connected, scaled 0-5/30A. 50/60Hz E243-026A-G-LS-LS-C77.5A direct connected, scaled 0-7.5/45A. 50/60Hz E243-026A-G-MF-MF-C710A direct connected, scaled 0-10/60A. 50/60Hz E243-026A-G-MT-MT-C715A direct connected, scaled 0-15/90A. 50/60Hz E243-026A-G-ND-ND-C720A direct connected, scaled 0-20/120A. 50/60Hz E243-026A-G-NG-NG-C725A direct connected, scaled 0-25/150A. 50/60Hz E243-026A-G-NJ-NJ-C730A direct connected, scaled 0-30/180A. 50/60Hz E243-026A-G-NL-NL-C740A direct connected, scaled 0-40/240A. 50/60Hz E243-026A-G-NP-NP-C750A direct connected, scaled 0-50/300A. 50/60Hz E243-026A-G-NT-NT-C760A direct connected, scaled 0-60/360A. 50/60Hz E243-026A-G-NW-NW-C7
Description Code
CROMPTON
5A CT operated, scaled 0-1/6A E243-026A-G-LS-LA-C75A CT operated, scaled 0-2/12A E243-026A-G-LS-LE-C75A CT operated, scaled 0-2.5/15A E243-026A-G-LS-LF-C75A CT operated, scaled 0-5/30A E243-026A-G-LS-LS-C75A CT operated, scaled 0-7.5/45A E243-026A-G-LS-MF-C75A CT operated, scaled 0-10/60A E243-026A-G-LS-MT-C75A CT operated, scaled 0-15/90A E243-026A-G-LS-ND-C75A CT operated, scaled 0-20/120A E243-026A-G-LS-NG-C75A CT operated, scaled 0-25/150A E243-026A-G-LS-NJ-C75A CT operated, scaled 0-30/180A E243-026A-G-LS-NL-C75A CT operated, scaled 0-40/240A E243-026A-G-LS-NP-C75A CT operated, scaled 0-50/300A E243-026A-G-LS-NT-C75A CT operated, scaled 0-60/360A E243-026A-G-LS-NW-C75A CT operated, scaled 0-75/450A E243-026A-G-LS-PB-C75A CT operated, scaled 0-80/480A E243-026A-G-LS-PD-C75A CT operated, scaled 0-100/600A E243-026A-G-LS-PK-C75A CT operated, scaled 0-120/720A E243-026A-G-LS-PQ-C75A CT operated, scaled 0-125/750A E243-026A-G-LS-PS-C75A CT operated, scaled 0-150/900A E243-026A-G-LS-PZ-C75A CT operated, scaled 0-200/1200A E243-026A-G-LS-RL-C75A CT operated, scaled 0-250/1500A E243-026A-G-LS-RS-C75A CT operated, scaled 0-300/1800A E243-026A-G-LS-RX-C75A CT operated, scaled 0-400/2400A E243-026A-G-LS-SC-C75A CT operated, scaled 0-500/3000A E243-026A-G-LS-SF-C75A CT operated, scaled 0-600/3600A E243-026A-G-LS-SJ-C75A CT operated, scaled 0-750/4500A E243-026A-G-LS-SM-C75A CT operated, scaled 0-800/4800A E243-026A-G-LS-SN-C75A CT operated, scaled 0-1000/6000A E243-026A-G-LS-SS-C75A CT operated, scaled 0-1200/7200A E243-026A-G-LS-ZW-C75A CT operated, scaled 0-1250/7500A E243-026A-G-LS-ZG-C75A CT operated, scaled 0-1500/9000A E243-026A-G-LS-A1-C75A CT operated, scaled 0-1600/9600A E243-026A-G-LS-Z7-C75A CT operated, scaled 0-2/12KA E243-026A-G-LS-TM-C75A CT operated, scaled 0-2.5/15KA E243-026A-G-LS-TU-C75A CT operated, scaled 0-3/18KA E243-026A-G-LS-UA-C7
DIN72 Moving Iron Shortscale AC Ammeters x 6 Overload
Direct Connected
DIN72 AC Ammeters Connect via CT X/5A with Fitted Dial Plate Motor
Overload Scaling 6 x In
28
Analogue Indicators –
AC Ammeters 90°, 96mm
DIN96 AC Ammeters x 6 Overload Direct Connected
DIN96 AC Ammeters Connect via CT X/5A with Fitted Dial Plate Motor
Overload Scaling 6 x In
Description Code
CROMPTON
0-1A direct connected, scaled 0-1/6A. 50/60Hz E244-026A-G-LA-LA-C72.5A direct connected, scaled 0-2.5/15A. 50/60Hz E244-026A-G-LF-LF-C75A direct connected, scaled 0-5/30A. 50/60Hz E244-026A-G-LS-LS-C77.5A direct connected, scaled 0-7.5/45A. 50/60Hz E244-026A-G-MF-MF-C710A direct connected, scaled 0-10/60A. 50/60Hz E244-026A-G-MT-MT-C715A direct connected, scaled 0-15/90A. 50/60Hz E244-026A-G-ND-ND-C720A direct connected, scaled 0-20/120A. 50/60Hz E244-026A-G-NG-NG-C725A direct connected, scaled 0-25/150A. 50/60Hz E244-026A-G-NJ-NJ-C730A direct connected, scaled 0-30/180A. 50/60Hz E244-026A-G-NL-NL-C740A direct connected, scaled 0-40/240A. 50/60Hz E244-026A-G-NP-NP-C750A direct connected, scaled 0-50/300A. 50/60Hz E244-026A-G-NT-NT-C760A direct connected, scaled 0-60/360A. 50/60Hz E244-026A-G-NW-NW-C7
Description Code
CROMPTON
5/30A CT operated, scaled 0-1/6A. 50/60Hz E244-026A-G-LS-LA-C75/30A CT operated, scaled 0-2/12A. 50/60Hz E244-026A-G-LS-LE-C75/30A CT operated, scaled 0-2.5/15A. 50/60Hz E244-026A-G-LS-LF-C75/30A CT operated, scaled 0-5/30A. 50/60Hz E244-026A-G-LS-LS-C75/30A CT operated, scaled 0-7.5/45A. 50/60Hz E244-026A-G-LS-MF-C75/30A CT operated, scaled 0-10/60A. 50/60Hz E244-026A-G-LS-MT-C75/30A CT operated, scaled 0-15/90A. 50/60Hz E244-026A-G-LS-ND-C75/30A CT operated, scaled 0-20/120A. 50/60Hz E244-026A-G-LS-NG-C75/30A CT operated, scaled 0-25/150A. 50/60Hz E244-026A-G-LS-NJ-C75/30A CT operated, scaled 0-30/180A. 50/60Hz E244-026A-G-LS-NL-C75/30A CT operated, scaled 0-40/240A. 50/60Hz E244-026A-G-LS-NP-C75/30A CT operated, scaled 0-50/300A. 50/60Hz E244-026A-G-LS-NT-C75/30A CT operated, scaled 0-60/360A. 50/60Hz E244-026A-G-LS-NW-C75/30A CT operated, scaled 0-75/450A. 50/60Hz E244-026A-G-LS-PB-C75/30A CT operated, scaled 0-80/480A. 50/60Hz E244-026A-G-LS-PD-C75/30A CT operated, scaled 0-100/600A. 50/60Hz E244-026A-G-LS-PK-C75/30A CT operated, scaled 0-120/720A. 50/60Hz E244-026A-G-LS-PQ-C75/30A CT operated, scaled 0-125/750A. 50/60Hz E244-026A-G-LS-PS-C75/30A CT operated, scaled 0-150/900A. 50/60Hz E244-026A-G-LS-PZ-C75/30A CT operated, scaled 0-200/1200A. 50/60Hz E244-026A-G-LS-RL-C75/30A CT operated, scaled 0-250/1500A. 50/60Hz E244-026A-G-LS-RS-C75/30A CT operated, scaled 0-300/1800A. 50/60Hz E244-026A-G-LS-RX-C75/30A CT operated, scaled 0-400/2400A. 50/60Hz E244-026A-G-LS-SC-C75/30A CT operated, scaled 0-500/3000A. 50/60Hz E244-026A-G-LS-SF-C75/30A CT operated, scaled 0-600/3600A. 50/60Hz E244-026A-G-LS-SJ-C75/30A CT operated, scaled 0-750/4500A. 50/60Hz E244-026A-G-LS-SM-C75/30A CT operated, scaled 0-800/4800A. 50/60Hz E244-026A-G-LS-SN-C75/30A CT operated, scaled 0-1000/6000A. 50/60Hz E244-026A-G-LS-SS-C75/30A CT operated, scaled 0-1200/7200A. 50/60Hz E244-026A-G-LS-ZW-C75/30A CT operated, scaled 0-1250/7500A. 50/60Hz E244-026A-G-LS-BF-C75/30A CT operated, scaled 0-1500/9000A. 50/60Hz E244-026A-G-LS-A1-C75/30A CT operated, scaled 0-1600/9600A. 50/60Hz E244-026A-G-LS-Z7-C75/30A CT operated, scaled 0-2/12KA. 50/60Hz E244-026A-G-LS-TM-C75/30A CT operated, scaled 0-2.5/15KA. 50/60Hz E244-026A-G-LS-TU-C75/30A CT operated, scaled 0-3/18KA. 50/60Hz E244-026A-G-LS-UA-C7
29
DIN48 AC Voltmeters
DIN72 AC Voltmeters
DIN96 AC Voltmeters
Analogue Indicators – AC Voltmeters 90°
Description Code
CROMPTON
0-150V direct connected.Scaled 0-150V. 50/60Hz E242-75V-G-PZ-PZ-C7
0-300V direct connected. Scaled 0-300V. 50/60Hz E242-75V-G-RX-RX-C7
0-500V direct connected. Scaled 0-500V. 50/60Hz E242-75V-G-SF-SF-C7
0-600V direct connected. Scaled 0-600V. 50/60Hz E242-75V-G-SJ-SJ-C7
Description Code
CROMPTON
0-150V direct connected.Scaled 0-150V. 50/60Hz E243-02V-G-PZ-PZ-C7
0-300V direct connected. Scaled 0-300V. 50/60Hz E243-02V-G-RX-RX-C7
0-500V direct connected. Scaled 0-500V. 50/60Hz E243-02V-G-SF-SF-C7
0-600V direct connected. Scaled 0-600V. 50/60Hz E243-02V-G-SJ-SJ-C7
Description Code
CROMPTON
0-150V direct connected. Scaled 0-150V. 50/60Hz E244-02V-G-PZ-PZ-C7
0-300V direct connected. Scaled 0-300V. 50/60Hz E244-02V-G-RX-RX-C7
0-500V direct connected. Scaled 0-500V. 50/60Hz E244-02V-G-SF-SF-C7
0-600V direct connected. Scaled 0-600V. 50/60Hz E244-02V-G-SJ-SJ-C7
Analogue Indicators – Frequency Meters 90°
DIN48 Frequency Meters
DIN72 Frequency Meters
DIN96 Frequency Meters
Description Code
CROMPTON
45-55Hz 100-125V, scaled 45/50/55Hz E242-41S-G-PL-AG-AG45-55Hz 200-250V, scaled 45/50/55Hz E242-41S-G-RN-AG-AG45-55Hz 400V, scaled 45/50/55Hz E242-41S-G-SC-AG-AG45-65Hz 100-125V, scaled 45/55/65Hz E242-41S-G-PL-AJ-AJ45-65Hz 200-250V, scaled 45/56/65Hz E242-41S-G-RN-AJ-AJ45-65Hz 400V, scaled 45/55/65Hz E242-41S-G-SC-AJ-AJ55-65Hz 100-125V, scaled 55/60/65Hz E242-41S-G-PL-AN-AN55-65Hz 200-250V, scaled 55/60/65Hz E242-41S-G-RN-AN-AN55-65Hz 400V, scaled 55/60/65Hz E242-41S-G-SC-AN-AN
Description Code
CROMPTON
45-55Hz 100-125V, scaled 45/50/55Hz E243-41S-G-PL-AG-AG45-55Hz 100-125V, scaled 45/50/55Hz E244-41S-G-PL-AG-AG45-55Hz 200-250V, scaled 45/50/55Hz E244-41S-G-RN-AG-AG45-55Hz 400V, scaled 45/50/55Hz E244-41S-G-SC-AG-AG45-65Hz 100-125V, scaled 45/55/65Hz E244-41S-G-PL-AJ-AJ45-65Hz 200-250V, scaled 45/56/65Hz E244-41S-G-RN-AJ-AJ45-65Hz 400V, scaled 45/55/65Hz E244-41S-G-SC-AJ-AJ55-65Hz 100-125V, scaled 55/60/65Hz E244-41S-G-PL-AN-AN55-65Hz 200-250V, scaled 55/60/65Hz E244-41S-G-RN-AN-AN55-65Hz 400V, scaled 55/60/65Hz E244-41S-G-SC-AN-AN
Description Code
CROMPTON
45-55Hz 100-125V, scaled 45/50/55Hz E243-41S-G-PL-AG-AG45-55Hz 200-250V, scaled 45/50/55Hz E243-41S-G-RN-AG-AG45-55Hz 400V, scaled 45/50/55Hz E243-41S-G-SC-AG-AG45-65Hz 100-125V, scaled 45/55/65Hz E243-41S-G-PL-AJ-AJ45-65Hz 200-250V, scaled 45/56/65Hz E243-41S-G-RN-AJ-AJ45-65Hz 400V, scaled 45/55/65Hz E243-41S-G-SC-AJ-AJ55-65Hz 100-125V, scaled 55/60/65Hz E243-41S-G-PL-AN-AN55-65Hz 200-250V, scaled 55/60/65Hz E243-41S-G-RN-AN-AN55-65Hz 400V, scaled 55/60/65Hz E243-41S-G-SC-AN-AN
30
31
Description Code
CROMPTON
100-125V ac 50Hz M242-155-G-PL-ZH-C5200-250V ac 50Hz M242-155-G-RN-ZH-C5380-440V ac 50Hz M242-155-G-RY-ZH-C5100-125V ac 60Hz M242-156-G-PL-ZH-C6200-250V ac 60Hz M242-156-G-RN-ZH-C6380-440V ac 60Hz M242-156-G-RY-ZH-C66-30V dc M242-157-G-BU-ZH-DC10-80V dc M242-157-G-NR-ZH-DC110V dc M242-157-G-PM-ZH-DC
M series Elapsed time or hours run meters
DIN48 AC Hours Run Meter
Description Code Delivery £
CROMPTON
100-125V ac 50Hz M243-155-G-PL-ZH-C5 A 18.50200-250V ac 50Hz M243-155-G-RN-ZH-C5 A 18.50380-440V ac 50Hz M243-155-G-RY-ZH-C5 A 18.50100-125V ac 60Hz M243-156-G-PL-ZH-C6 A 18.50200-250V ac 60Hz M243-156-G-RN-ZH-C6 A 18.50380-440V ac 60Hz M243-156-G-RY-ZH-C6 A 18.506-30V dc M243-157-G-BU-ZH-DC A 18.5010-80V dc M243-157-G-NR-ZH-DC A 18.50110V dc M243-157-G-PM-ZH-DC A 18.50
DIN72 AC Hours Run Meter
Description Code Delivery £
CROMPTON
100-125V ac 50Hz M244-155-G-PL-ZH-C5 A 20.50200-250V ac 50Hz M244-155-G-RN-ZH-C5 A 20.50380-440V ac 50Hz M244-155-G-RY-ZH-C5 A 20.50100-125V ac 60Hz M244-156-G-PL-ZH-C6 A 20.50200-250V ac 60Hz M244-156-G-RN-ZH-C6 A 20.50380-440V ac 60Hz M244-156-G-RY-ZH-C6 A 20.506-30V dc M244-157-G-BU-ZH-DC A 20.5010-80V dc M244-157-G-NR-ZH-DC A 20.50110V dc M244-157-G-PM-ZH-D A 20.50
DIN96 AC Hours Run Meter
Analogue Indicators – Hours Run Meters
Elapsed time meters (ETM) or hours run meters monitor ON/RUN time of plant and emergency, allowing the user to effectively controlproduction efficiency, cost estimation and service period monitoring forpreventative maintenance. Time is measured in increments of 0.01h up to99999.99 hours after which the meter automatically resets to zero. Metersare non resettable before this time to prevent accidental resetting.
Specifications
AC
Display 99999.99Voltage 100-125V ac
200-250V ac380-440V ac
Frequency 50 or 60HzOperating -25C to +80CtemperatureBurden 1VA (100-25V ac)
2VA (200-250V ac)3.5VA (380-440V ac)
DC
Display 99999.99Voltage 6-30V dc
10-80V dc110V dc
Operating -20C to +70CtemperatureBurden 0.5VA (6-30V dc)
1VA (10-80V dc)1.5VA (110V dc)
32
Analogue Indicators – DC Ammeters 90°
DIN48 DC Ammeters Direct Connect
DIN48 DC Ammeters Connect via Shunt X/75mV with Fitted Dial Plate –
Normal Scaling
Description Code Delivery £
CROMPTON
75mV shunt operated, scaled 0-1A. 50/60Hz E242-89A-G-EJ-LA B 32.0075mV shunt operated, scaled 0-2A. 50/60Hz E242-89A-G-EJ-LE B 32.0075mV shunt operated, scaled 0-5A. 50/60Hz E242-89A-G-EJ-LS B 32.0075mV shunt operated, scaled 0-10A. 50/60Hz E242-89A-G-EJ-MT B 32.0075mV shunt operated, scaled 0-15A. 50/60Hz E242-89A-G-EJ-ND B 32.0075mV shunt operated, scaled 0-20A. 50/60Hz E242-89A-G-EJ-NG B 32.0075mV shunt operated, scaled 0-25A. 50/60Hz E242-89A-G-EJ-NJ B 32.0075mV shunt operated, scaled 0-30A. 50/60Hz E242-89A-G-EJ-NL B 32.0075mV shunt operated, scaled 0-40A. 50/60Hz E242-89A-G-EJ-NP B 32.0075mV shunt operated, scaled 0-50A. 50/60Hz E242-89A-G-EJ-NT B 32.0075mV shunt operated, scaled 0-60A. 50/60Hz E242-89A-G-EJ-NW B 32.0075mV shunt operated, scaled 0-75A. 50/60Hz E242-89A-G-EJ-PB B 32.0075mV shunt operated, scaled 0-80A. 50/60Hz E242-89A-G-EJ-PD B 32.0075mV shunt operated, scaled 0-100A. 50/60Hz E242-89A-G-EJ-PK B 32.0075mV shunt operated, scaled 0-150A. 50/60Hz E242-89A-G-EJ-PZ B 32.0075mV shunt operated, scaled 0-200A. 50/60Hz E242-89A-G-EJ-RL B 32.0075mV shunt operated, scaled 0-250A. 50/60Hz E242-89A-G-EJ-RS B 32.0075mV shunt operated, scaled 0-300A. 50/60Hz E242-89A-G-EJ-RX B 32.0075mV shunt operated, scaled 0-400A. 50/60Hz E242-89A-G-EJ-SC B 32.0075mV shunt operated, scaled 0-500A. 50/60Hz E242-89A-G-EJ-SF B 32.0075mV shunt operated, scaled 0-600A. 50/60Hz E242-89A-G-EJ-SJ B 32.0075mV shunt operated, scaled 0-750A. 50/60Hz E242-89A-G-EJ-SM B 32.0075mV shunt operated, scaled 0-800A. 50/60Hz E242-89A-G-EJ-SN B 32.0075mV shunt operated, scaled 0-1000A. 50/60Hz E242-89A-G-EJ-SS B 32.0075mV shunt operated, scaled 0-1500A. 50/60Hz E242-89A-G-EJ-TC B 32.0075mV shunt operated, scaled 0-2000A. 50/60Hz E242-89A-G-EJ-TM B 32.00
Description Code Delivery £
CROMPTON
1A direct connected, scaled 0-1A. 50/60Hz E242-89A-G-LA-LA A 32.002A direct connected, scaled 0-2A. 50/60Hz E242-89A-G-LE-LE A 32.003A direct connected, scaled 0-3A. 50/60Hz E242-89A-G-LJ-LJ A 32.004A direct connected, scaled 0-4A. 50/60Hz E242-89A-G-LL-LL A 32.005A direct connected, scaled 0-5A. 50/60Hz E242-89A-G-LS-LS A 32.0010A direct connected, scaled 0-10A. 50/60Hz E242-89A-G-MT-MT A 32.0015A direct connected, scaled 0-15A. 50/60Hz E242-89A-G-ND-ND A 32.0020A direct connected, scaled 0-20A. 50/60Hz E242-89A-G-NG-NG A 32.0025A direct connected, scaled 0-25A. 50/60Hz E242-89A-G-NJ-NJ A 32.00
33
DIN72 DC Ammeters Direct Connected
DIN72 DC Ammeters Connect via Shunt X/75mV with Fitted Dial Plate –
Normal Scaling
Description Code Delivery £
CROMPTON
75mV shunt operated, scaled 0-1A. 50/60Hz E243-01A-G-EJ-LA B 32.0075mV shunt operated, scaled 0-2A. 50/60Hz E243-01A-G-EJ-LE B 32.0075mV shunt operated, scaled 0-5A. 50/60Hz E243-01A-G-EJ-LS B 32.0075mV shunt operated, scaled 0-10A. 50/60Hz E243-01A-G-EJ-MT B 32.0075mV shunt operated, scaled 0-15A. 50/60Hz E243-01A-G-EJ-ND B 32.0075mV shunt operated, scaled 0-20A. 50/60Hz E243-01A-G-EJ-NG B 32.0075mV shunt operated, scaled 0-25A. 50/60Hz E243-01A-G-EJ-NJ B 32.0075mV shunt operated, scaled 0-30A. 50/60Hz E243-01A-G-EJ-NL B 32.0075mV shunt operated, scaled 0-40A. 50/60Hz E243-01A-G-EJ-NP B 32.0075mV shunt operated, scaled 0-50A. 50/60Hz E243-01A-G-EJ-NT B 32.0075mV shunt operated, scaled 0-60A. 50/60Hz E243-01A-G-EJ-NW B 32.0075mV shunt operated, scaled 0-75A. 50/60Hz E243-01A-G-EJ-PB B 32.0075mV shunt operated, scaled 0-80A. 50/60Hz E243-01A-G-EJ-PD B 32.0075mV shunt operated, scaled 0-100A. 50/60Hz E243-01A-G-EJ-PK B 32.0075mV shunt operated, scaled 0-150A. 50/60Hz E243-01A-G-EJ-PZ B 32.0075mV shunt operated, scaled 0-200A. 50/60Hz E243-01A-G-EJ-RL B 32.0075mV shunt operated, scaled 0-250A. 50/60Hz E243-01A-G-EJ-RS B 32.0075mV shunt operated, scaled 0-300A. 50/60Hz E243-01A-G-EJ-RX B 32.0075mV shunt operated, scaled 0-400A. 50/60Hz E243-01A-G-EJ-SC B 32.0075mV shunt operated, scaled 0-500A. 50/60Hz E243-01A-G-EJ-SF B 32.0075mV shunt operated, scaled 0-600A. 50/60Hz E243-01A-G-EJ-SJ B 32.0075mV shunt operated, scaled 0-750A. 50/60Hz E243-01A-G-EJ-SM B 32.0075mV shunt operated, scaled 0-800A. 50/60Hz E243-01A-G-EJ-SN B 32.0075mV shunt operated, scaled 0-1000A. 50/60Hz E243-01A-G-EJ-SS B 32.0075mV shunt operated, scaled 0-1500A. 50/60Hz E243-01A-G-EJ-TC B 32.0075mV shunt operated, scaled 0-2000A. 50/60Hz E243-01A-G-EJ-TM B 32.00
Description Code Delivery £
CROMPTON
1A direct connected, scaled 0-1A. 50/60Hz E243-01A-G-LA-LA A 32.002A direct connected, scaled 0-2A. 50/60Hz E243-01A-G-LE-LE A 32.003A direct connected, scaled 0-3A. 50/60Hz E243-01A-G-LJ-LJ A 32.004A direct connected, scaled 0-4A. 50/60Hz E243-01A-G-LL-LL A 32.005A direct connected, scaled 0-5A. 50/60Hz E243-01A-G-LS-LS A 32.0010A direct connected, scaled 0-10A. 50/60Hz E243-01A-G-MT-MT A 32.0015A direct connected, scaled 0-15A. 50/60Hz E243-01A-G-ND-ND A 32.0020A direct connected, scaled 0-20A. 50/60Hz E243-01A-G-NG-NG A 32.0025A direct connected, scaled 0-25A. 50/60Hz E243-01A-G-NJ-NJ A 32.0030A direct connected, scaled 0-30A. 50/60Hz E243-01A-G-NL-NL A 35.0040A direct connected, scaled 0-40A. 50/60Hz E243-01A-G-NP-NP A 35.00
34
DIN96 DC Ammeters Direct Connect
DIN96 DC Ammeters Connect via Shunt X/75mV with Fitted Dial Plate –
Normal Scaling
Description Code Delivery £
CROMPTON
75mV shunt operated, scaled 0-1A. 50/60Hz E244-01A-G-EJ-LA B 35.0075mV shunt operated, scaled 0-2A. 50/60Hz E244-01A-G-EJ-LE B 35.0075mV shunt operated, scaled 0-5A. 50/60Hz E244-01A-G-EJ-LS B 35.0075mV shunt operated, scaled 0-10A. 50/60Hz E244-01A-G-EJ-MT B 35.0075mV shunt operated, scaled 0-15A. 50/60Hz E244-01A-G-EJ-ND B 35.0075mV shunt operated, scaled 0-20A. 50/60Hz E244-01A-G-EJ-NG B 35.0075mV shunt operated, scaled 0-25A. 50/60Hz E244-01A-G-EJ-NJ B 35.0075mV shunt operated, scaled 0-30A. 50/60Hz E244-01A-G-EJ-NL B 35.0075mV shunt operated, scaled 0-40A. 50/60Hz E244-01A-G-EJ-NP B 35.0075mV shunt operated, scaled 0-50A. 50/60Hz E244-01A-G-EJ-NT B 35.0075mV shunt operated, scaled 0-60A. 50/60Hz E244-01A-G-EJ-NW B 35.0075mV shunt operated, scaled 0-75A. 50/60Hz E244-01A-G-EJ-PB B 35.0075mV shunt operated, scaled 0-80A. 50/60Hz E244-01A-G-EJ-PD B 35.0075mV shunt operated, scaled 0-100A. 50/60Hz E244-01A-G-EJ-PK B 35.0075mV shunt operated, scaled 0-150A. 50/60Hz E244-01A-G-EJ-PZ B 35.0075mV shunt operated, scaled 0-200A. 50/60Hz E244-01A-G-EJ-RL B 35.0075mV shunt operated, scaled 0-250A. 50/60Hz E244-01A-G-EJ-RS B 35.0075mV shunt operated, scaled 0-300A. 50/60Hz E244-01A-G-EJ-RX B 35.0075mV shunt operated, scaled 0-400A. 50/60Hz E244-01A-G-EJ-SC B 35.0075mV shunt operated, scaled 0-500A. 50/60Hz E244-01A-G-EJ-SF B 35.0075mV shunt operated, scaled 0-600A. 50/60Hz E244-01A-G-EJ-SJ B 35.0075mV shunt operated, scaled 0-750A. 50/60Hz E244-01A-G-EJ-SM B 35.0075mV shunt operated, scaled 0-800A. 50/60Hz E244-01A-G-EJ-SN B 35.0075mV shunt operated, scaled 0-1000A. 50/60Hz E244-01A-G-EJ-SS B 35.0075mV shunt operated, scaled 0-1500A. 50/60Hz E244-01A-G-EJ-TC B 35.0075mV shunt operated, scaled 0-2000A. 50/60Hz E244-01A-G-EJ-TM B 35.00
Description Code Delivery £
CROMPTON
1A direct connected, scaled 0-1A. 50/60Hz E244-01A-G-LA-LA A 32.002A direct connected, scaled 0-2A. 50/60Hz E244-01A-G-LE-LE A 32.003A direct connected, scaled 0-3A. 50/60Hz E244-01A-G-LJ-LJ A 32.004A direct connected, scaled 0-4A. 50/60Hz E244-01A-G-LL-LL A 32.005A direct connected, scaled 0-5A. 50/60Hz E244-01A-G-LS-LS A 32.0010A direct connected, scaled 0-10A. 50/60Hz E244-01A-G-MT-MT A 32.0015A direct connected, scaled 0-15A. 50/60Hz E244-01A-G-ND-ND A 32.0020A direct connected, scaled 0-20A. 50/60Hz E244-01A-G-NG-NG A 32.0025A direct connected, scaled 0-25A. 50/60Hz E244-01A-G-NJ-NJ A 32.0030A direct connected, scaled 0-30A. 50/60Hz E244-01A-G-NL-NL A 35.0040A direct connected, scaled 0-40A. 50/60Hz E244-01A-G-NP-NP A 35.00
35
Dimensions
D A B
cutout
48 x 48 45 x 45 472 x 72 68 x 68 496 x 96 92 x 92 4
C C
current ac current ac
0-30A : 64 6-60A : 67>30A : 67 >60A : 78
A
DIN48 DC Voltmeters
Description Code Delivery £
CROMPTON
0-15V direct connected, scaled 0-15V. 50/60Hz E243-01V-G-ND-ND A 31.800-30V direct connected, scaled 0-30V. 50/60Hz E243-01V-G-NL-NL A 31.800-40V direct connected, scaled 0-40V. 50/60Hz E243-01V-G-NP-NP A 31.800-60V direct connected, scaled 0-60V. 50/60Hz E243-01V-G-NW-NW A 31.800-100V direct connected, scaled 0-100V. 50/60Hz E243-01V-G-PK-PK A 31.800-150V direct connected, scaled 0-150V. 50/60Hz E243-01V-G-PZ-PZ A 31.800-200V direct connected, scaled 0-200V. 50/60Hz E243-01V-G-RL-RL A 31.800-250V direct connected, scaled 0-250V. 50/60Hz E243-01V-G-RS-RS A 31.800-300V direct connected, scaled 0-300V. 50/60Hz E243-01V-G-RX-RX A 31.800-400V direct connected, scaled 0-400V. 50/60Hz E243-01V-G-SC-SC A 31.800-500V direct connected, scaled 0-500V. 50/60Hz E243-01V-G-SF-SF A 31.80
DIN72 DC Voltmeters
DIN96 DC Voltmeters
Analogue Indicators – DC Voltmeters 90°
Description Code Delivery £
CROMPTON
0-15V direct connected, scaled 0-15V. 50/60Hz E244-01V-G-ND-ND A 31.800-30V direct connected, scaled 0-30V. 50/60Hz E244-01V-G-NL-NL A 31.800-40V direct connected, scaled 0-40V. 50/60Hz E244-01V-G-NP-NP A 31.800-60V direct connected, scaled 0-60V. 50/60Hz E244-01V-G-NW-NW A 31.800-100V direct connected, scaled 0-100V. 50/60Hz E244-01V-G-PK-PK A 31.800-150V direct connected, scaled 0-150V. 50/60Hz E244-01V-G-PZ-PZ A 31.800-200V direct connected, scaled 0-200V. 50/60Hz E244-01V-G-RL-RL A 31.800-250V direct connected, scaled 0-250V. 50/60Hz E244-01V-G-RS-RS A 31.800-300V direct connected, scaled 0-300V. 50/60Hz E244-01V-G-RX-RX A 31.800-400V direct connected, scaled 0-400V. 50/60Hz E244-01V-G-SC-SC A 31.800-500V direct connected, scaled 0-500V. 50/60Hz E244-01V-G-SF-SF A 31.80
Description Code Delivery £
CROMPTON
0-15V direct connected, scaled 0-15V. 50/60Hz E242-89V-G-ND-ND A 31.800-30V direct connected, scaled 0-30V. 50/60Hz E242-89V-G-NL-NL A 31.800-40V direct connected, scaled 0-40V. 50/60Hz E242-89V-G-NP-NP A 31.800-60V direct connected, scaled 0-60V. 50/60Hz E242-89V-G-NW-NW A 31.800-100V direct connected, scaled 0-100V. 50/60Hz E242-89V-G-PK-PK A 31.800-150V direct connected, scaled 0-150V. 50/60Hz E242-89V-G-PZ-PZ A 31.800-200V direct connected, scaled 0-200V. 50/60Hz E242-89V-G-RL-RL A 31.800-250V direct connected, scaled 0-250V. 50/60Hz E242-89V-G-RS-RS A 31.800-300V direct connected, scaled 0-300V. 50/60Hz E242-89V-G-RX-RX A 31.800-400V direct connected, scaled 0-400V. 50/60Hz E242-89V-G-SC-SC A 31.800-500V direct connected, scaled 0-500V. 50/60Hz E242-89V-G-SF-SF A 31.80
B
Selector Switches
36
Description Nameplate Code Delivery £
CROMPTON
4-position 20Aammeter switch L1-L2-L3-0 SO3-SAB A 13.00
Ammeter Switch
Description Nameplate Code Delivery £
CROMPTON
L1N-L2N-L3N7-position 20A -0- SO3-SVD A 13.00voltmeter switch L1L2-L2L3-L3L1
Voltmeter Switch
Dimensions
Connections
High quality analogue instruments designed to measure an extensiverange of electrical and electronic parameters. This comprehensive rangeoffers DIN instruments, ANSI switchboard meters, panel indicators,sealed and ruggedised instruments and complementary selectorswitches for line-to-line and line-to-neutral readings. Instruments areprecision engineered and robust in design, ensuring accuratemeasurement and display in the most demanding of environments.All instruments are available in a range of styles, sizes and specificationsto meet the exacting needs of your industry.
Current Transformers
37
55mm
78mm
45mm
Moulded case type
Bar Primary PEWPL
Dimensions : 55mm width x45mm depth x78mm height
Fixing : M8
Weight : 0,45 Kg
Through Hole PE201
Dimensions : 55mm width x45mm depth x78mm height
Hole : Ø 20 mm
Weight : 0,4 Kg 78mm
45mm55mm
Ratio VA VA VA Code Delivery £
Class 3 Class 1 Class 0,5 CROMPTON
5/5 – 5 – PEWPL-5/5 A 11.0010/5 – 5 – PEWPL-10/5 A 11.0015/5 – 5 – PEWPL-15/5 A 11.0020/5 – 5 – PEWPL-20/5 A 11.0025/5 – 5 – PEWPL-25/5 A 11.0030/5 – 5 – PEWPL-30/5 A 11.0040/5 – 5 – PEWPL-40/5 A 11.0050/5 – 5 –- PEWPL-50/5 A 11.00
Ratio VA VA VA Code Delivery £
Class 3 Class 1 Class 0,5 CROMPTON
30/5 1.5 – – PE201-30/5 A 11.0040/5 1.5 – – PE201-40/5 A 11.0050/5 – 1.5 – PE201-50/5 A 11.0060/5 – 1.5 – PE201-60/5 A 11.0080/5 – 4 – PE201-80/5 A 11.00100/5 – 4 – PE201-100/5 A 11.00200/5 – 8 – PE201-200/5 A 11.00250/5 – 10 – PE201-250/5 A 11.00
Current Transformers perform two main functions:
a Accurate reproduction at a given ratio in a secondary winding of thecurrent passing through the primary winding.
b Electrical separation between both windings.
These factors make it possible to:• Separate the circuit in which measurements are taken, which makes
handling of the meters safer, because normally one end of the secondarywinding is grounded.
• Measure high currents with low current input meters, therefore, whateverthe primary rated current value may be, the secondary current can remaina constant 5 or 1 amp.
38
70mm
32mm
50mm
Through Hole PE401
Dimensions : 60mm width x32mm depth x78mm height
Hole : 40x12 mm and Ø 28 mm
Weight : 0,4Kg
Through Hole PE301
Dimensions : 55mm width x32mm depth x70mm height
Hole : 30x10mm, 25x15mm and 20x20mm, horizontal and vertical
Weight : 0,22 Kg
60mm
78mm
32mm
Ratio VA VA VA Code Delivery £
Class 3 Class 1 Class 0,5 CROMPTON
150/5 – 2.5 – PE401-150/5 A 8.00200/5 – 2.5 – PE401-200/5 A 8.00250/5 5 2.5 – PE401-250/5 A 8.00300/5 5 2.5 – PE401-300/5 A 8.00400/5 7.5 5 – PE401-400/5 A 8.00500/5 – 7.5 5 PE401-500/5 A 8.00600/5 – 7.5 5 PE401-600/5 A 8.00750/5 – 7.5 5 PE401-750/5 A 8.00800/5 – 7.5 5 PE401-800/5 A 8.00
Ratio VA VA VA Code Delivery £
Class 3 Class 1 Class 0,5 CROMPTON
75/5 1 – – PE301-75/5 A 7.0080/5 1 – – PE301-80/5 A 7.00100/5 – 1 – PE301-100/5 A 7.00125/5 – 1 – PE301-125/5 A 7.00150/5 2.5 1 – PE301-150/5 A 7.00200/5 3 2.5 – PE301-200/5 A 7.00250/5 3 2.5 – PE301-250/5 A 7.00300/5 5 2.5 – PE301-300/5 A 7.45400/5 7.5 5 – PE301-400/5 A 7.45500/5 7.5 5 – PE301-500/5 A 7.45600/5 7.5 5 – PE301-600/5 A 7.45
39
Through Hole PE801
Dimensions : 100mm width x40mm depth x122mm height
Hole : 80x10mm, 60x30mm, 50x50mm and Ø 60mm
Weight : 0,5Kg
85mm
108mm
32mm
Through Hole PE601
Dimensions : 85mm width x32mm depth x108mm height
Hole : 60x10mm, 50x30mm and Ø 45mm
Weight : 0,45Kg
100mm
122mm
40mm
Ratio VA VA VA Code Delivery £
Class 3 Class 1 Class 0,5 CROMPTON
400/5 – 10 5 PE801-400/5 A 10.80500/5 – 10 5 PE801-500/5 A 10.80600/5 15 10 5 PE801-600/5 A 10.80750/5 – 15 10 PE801-750/5 A 10.80800/5 – 15 10 PE801-800/5 A 10.801000/5 – 15 10 PE801-1000/5 A 10.801200/5 – 15 10 PE801-1200/5 A 10.801250/5 – 15 10 PE801-1250/5 A 10.801500/5 – 15 10 PE801-1500/5 A 10.801600/5 – 15 10 PE801-1600/5 A 10.802000/5 – 15 10 PE801-2000/5 A 10.80
Ratio VA VA VA Code Delivery £
Class 3 Class 1 Class 0,5 CROMPTON
400/5 – 10 – PE601-400/5 A 9.30500/5 – 10 – PE601-500/5 A 9.30600/5 – 15 10 PE601-600/5 A 9.30750/5 – 15 10 PE601-750/5 A 9.30800/5 – 15 10 PE601-800/5 A 9.301000/5 – 15 10 PE601-1000/5 A 9.301200/5 – – 15 PE601-1200/5 A 9.301250/5 – – 15 PE601-1250/5 A 9.301500/5 – – 15 PE601-1500/5 A 9.301600/5 – – 15 PE601-1600/5 A 9.30
40
Through Hole PE1001
Dimensions : 135mm width x40mm depth x160mm height
Hole : 100x30mm, 80x50mm, Ø 85mm
Weight : 0,7Kg
160mm
135mm40mm
Busbar Mounting RS125
Dimensions : 110mm width x62mm depth x182mm height
Hole : 126x36mm
Weight : 0,6Kg181.7mm
1230mm
Wire Holding Loop
Terminals x 4
Ratio VA VA VA Code Delivery £
Class 3 Class 1 Class 0,5 CROMPTON
800/5 – 30 15 RS125-800/5 A 18.501000/5 – 30 15 RS125-1000/5 A 20.501200/5 – 30 15 RS125-1200/5 A 23.001250/5 – 30 15 RS125-1250/5 A 23.001500/5 – 30 15 RS125-1500/5 A 27.501600/5 – 30 15 RS125-1600/5 A 28.502000/5 – 30 15 RS125-2000/5 A 33.002500/5 – 30 15 RS125-2500/5 A 39.003000/5 – 30 15 RS125-3000/5 A 44.003500/5 – 30 15 RS125-3500/5 A 50.004000/5 – 30 15 RS125-4000/5 A 57.00
Ratio VA VA VA Code Delivery £
Class 3 Class 1 Class 0,5 CROMPTON
500/5 – 10 5 PE1001-500/5 A 13.00600/5 15 10 5 PE1001-600/5 A 13.00750/5 – 15 10 PE1001-750/5 A 13.00800/5 – 15 10 PE1001-800/5 A 13.001000/5 – 15 15 PE1001-1000/5 A 13.001200/5 – 15 15 PE1001-1200/5 A 13.001250/5 – 15 15 PE1001-1250/5 A 13.001500/5 – 30 15 PE1001-1500/5 A 13.001600/5 – 30 15 PE1001-1600/5 A 13.002000/5 – 30 15 PE1001-2000/5 A 13.003000/5 – – 30 PE1001-3000/5 A 13.004000/5 – – 30 PE1001-4000/5 A 13.00
41
Dimensions
Ring Type
Tyco Electronics under its Crompton Instruments brand offers offers anextensive portfolio of current transformers that provide comprehensivemeasuring accuracy. MR transformers accurately measure high primarycurrents, converting the primary current into a proportional 5 amp secondary current.
Model type A B C D E
inside outside axel mounting mounting
diameter diameter length feet pitch feet
MR-28'S 28 70 40 77.5 92.5
MR-42'S 42 80 30 86 100
MR-45'S 45 80 30 86 100
MR-60'S 60 100 30 86 100
MR-85'S 85 120 20 86 100
MR-125'S 125 165 20 86 100
Dimensions and Connections
Model type Ratio range VA at VA at VA at Delivery £
Class 3 Class 1 Class 0.5
MR-28-30/5A 30/5 - - - A 9.00
MR-28-40/5A 40/5 1.5 - - A 9.00
MR-28-50/5A 50/5 2 - - A 9.00
MR-28-60/5A 60/5 2.5 - - A 9.00
MR-42-75/5A 75/5 1.5 A 9.00
MR-42-80/5A 80/5 1.5 A 9.00
MR-42-100/5A 100/5 5 3 1.5 A 9.00
MR-42-150/5A 150/5 10 3 2.5 A 9.00
MR-42-200/5A 200/5 10 5 3 A 9.20
MR-42-250/5A 250/5 10 7.5 5 A 9.20
MR-45-300/5A 300/5 15 10 5 A 9.30
MR-45-400/5A 400/5 15 10 5 A 9.50
MR-60-400/5A 400/5 15 10 7.5 A 9.90
MR-60-500/5A 500/5 20 15 7.5 A 10.10
MR-60-600/5A 600/5 20 15 10 A 10.40
MR-85-800/5A 800/5 20 15 10 A 15.50
MR-85-1000/5A 1000/5 25 20 15 A 17.00
MR-85-1200/5A 1200/5 25 20 15 A 19.00
MR-85-1500/5A 1500/5 25 20 15 A 21.00
MR-85-1600/5A 1600/5 25 20 15 A 23.50
MR-125-2000/-5 2000/5 25 20 15 A 27.00
MR-125-2500/-5 2500/5 25 20 15 A 27.50
MR-125-3000/-5 3000/5 25 20 15 A 28.00
MR-125-4000/-5 4000/5 25 20 15 A 29.00
Specifications
42
Dimensions
Split Core Type
The Crompton Instruments split core current transformer offers a costeffective and efficient method by which current can be measured withoutthe need to break into the conductor, thereby reducing installation andcommissioning time.
Model Case 1 Case 2 Case 3 Case 4 Case 5
A 20 50 80 80 80
B 30 80 80 120 160C 51 78 108 108 120D 89 114 144 144 184E 110 145 145 185 245F 34 32 32 32 52G 47 32 32 32 47H 40 32 32 32 52I 32 33 33 33 38Weight (Kg) 0.75 0.9 1.0 1.2 3.5
Burden VA Apperatureagainst class index Busbar/cable
Part no. Primary A 0.5 1 3 (mm) Delivery £
SCPKLSCA1 100/5 – – 1.5 20 x 30 B 62.00SCPZLSCA1 150/5 – – 2 20 x 30 B 62.00SCRLLSCA1 200/5 – 1.5 2.5 20 x 30 B 62.00SCRSLSCA1 250/5 – 2 4 20 x 30 B 62.00SCRXLSCA1 300/5 1.5 4 10 20 x 30 B 62.00SCSCLSCA1 400/5 2.5 6 10 20 x 30 B 62.00
SCRSLSCA2 250/5 1 2 4 50 x 80 B 67.00SCRXLSCA2 300/5 1.5 3 6 50 x 80 B 67.00SCSCLSCA2 400/5 1.5 3 10 50 x 80 B 67.00SCSFLSCA2 500/5 2.5 5 15 50 x 80 B 67.00SCSJLSCA2 600/5 2.5 5 17.5 50 x 80 B 67.00SCSMLSCA2 700/5 6 6 18 50 x 80 B 67.00SCSNLSCA2 800/5 3 7 18 50 x 80 B 67.00SCSSLSCA2 1000/5 5 10 20 50 x 80 B 67.00
SCRSLSCA3 250/5 1 2 4 80 x 80 B 75.00SCRXLSCA3 300/5 1.5 3 6 80 x 80 B 75.00SCSCLSCA3 400/5 1.5 3 10 80 x 80 B 75.00SCSFLSCA3 500/5 2.5 5 15 80 x 80 B 75.00SCSJLSCA3 600/5 2.5 5 17.5 80 x 80 B 75.00SCSMLSCA3 700/5 6 6 18 80 x 80 B 75.00SCSNLSCA3 800/5 3 7 18 80 x 80 B 75.00SCSSLSCA3 1000/5 5 10 20 80 x 80 B 75.00
SCSFLSCA4 500/5 – 4 12 80 x 120 B 115.00SCSJLSCA4 600/5 – 5 14 80 x 120 B 115.00SCSMLSCA4 750/5 2.5 6 17 80 x 120 B 115.00SCSNLSCA4 800/5 3 7 18 80 x 120 B 115.00SCSSLSCA4 1000/5 5 9 20 80 x 120 B 115.00SCSULSCA4 1200/5 6 11 24 80 x 120 B 115.00SCSVLSCA4 1250/5 7 15 28 80 x 120 B 115.00SCTCLSCA4 1500/5 8 17 30 80 x 120 B 115.00
SCSSLSCA5 1000/5 10 15 20 80 x 160 B 230.00SCTCLSCA5 1500/5 15 20 25 80 x 160 B 230.00SCTMLSCA5 2000/5 15 20 25 80 x 160 B 230.00SCTULSCA5 2500/5 15 20 25 80 x 160 B 230.00SCUJLSCA5 3000/5 20 25 30 80 x 160 B 230.00SCXZLSCA5 4000/5 20 25 30 80 x 160 B 230.00SCUJLSCA5 5000/5 20 25 30 80 x 160 B 230.00
Case 1
Case 2
Case 3
Case 4
Case 5
Dimensions and Connections
Specifications
43
Description Code Delivery £
CROMPTON
25A-75mV – Class 1 busbar mounted 876-92NW-NJEJ C 14.0030A-75mV – Class 1 busbar mounted 876-92NW-NLEJ C 14.0040A-75mV – Class 1 busbar mounted 876-92NW-NPEJ C 14.0050A-75mV – Class 1 busbar mounted 876-92NW-NTEJ C 15.0060A-75mV – Class 1 busbar mounted 876-92NW-NWEJ C 15.0075A-75mV – Class 1 busbar mounted 876-92NW-PBEJ C 15.0080A-75mV – Class 1 busbar mounted 876-92NW-PDEJ C 15.00100A-75mV – Class 1 busbar mounted 876-92NW-PKEJ C 15.00150A-75mV – Class 1 busbar mounted 876-92NW-PZEJ C 16.00200A-75mV – Class 1 busbar mounted 876-92NW-RLEJ C 16.00250A-75mV – Class 1 busbar mounted 876-92NW-RSEJ C 16.00
Series 876
Description Code Delivery £
CROMPTON
1A-75mV class 0.5 base mounted 881-92MB-LAEJ C 33.002A-75mV class 0.5 base mounted 881-92MB-LEEJ C 33.005A-75mV class 0.5 base mounted 881-92MB-LSEJ C 33.0010A-75mV class 0.5 base mounted 881-92MB-MTEJ C 33.0015A-75mV class 0.5 base mounted 881-92MB-NDEJ C 33.0020A-75mV class 0.5 base mounted 881-92MB-NGEJ C 33.0025A-75mV class 0.5 base mounted 881-92MB-NJEJ C 33.0030A-75mV class 0.5 base mounted 881-92MB-NLEJ C 33.0030A-75mV class 0.5 busbar mounted 882-92MB-NLEJ C 29.0040A-75mV class 0.5 busbar mounted 882-92MB-NPEJ C 29.0050A-75mV class 0.5 busbar mounted 882-92MB-NTEJ C 29.0060A-75mV class 0.5 busbar mounted 882-92MB-NWEJ C 29.0075A-75mV class 0.5 busbar mounted 882-92MB-PBEJ C 29.0080A-75mV class 0.5 busbar mounted 882-92MB-PDEJ C 29.00100A-75mV class 0.5 busbar mounted 882-92MB-PKEJ C 29.00150A-75mV class 0.5 busbar mounted 882-92MB-PZEJ C 29.00200A-75mV class 0.5 busbar mounted 883-92MB-RLEJ C 37.00250A-75mV class 0.5 busbar mounted 883-92MB-RSEJ A 37.00300A-75mV class 0.5 busbar mounted 883-92MB-RXEJ A 37.00400A-75mV class 0.5 busbar mounted 883-92MB-SCEJ A 37.00500A-75mV class 0.5 busbar mounted 883-92MB-SFEJ C 52.00
Series 880
Dimensions
A = 80mm B = 100m
Dimensions
Shunts
2 Holes11 Ø
2 Holes14 Ø
Shunt 881 (1-30A) Shunt 882 (30-150A) Shunt 883 (200-500A)
44
Generator Set Controllers
Description Code Delivery £
CROMPTON
Engine cranking controlAutomatic shutdown on fault condition KEY-START A 54.50Pre-heat capabilityEngine cranking controlAutomatic shutdown on fault conditionPre-heat capability KEY-START-ALT A 73.50Over-speed sensing via alternator inputTachometer outputEngine cranking controlAutomatic shutdown on fault conditionPre-heat capability KEY-START-MAG A 74.50Over-speed sensing via magnetic pickup inputTachometer outputSpare keys set of 2 KEYS-KS A 15.00
KEY-START DIN72 Manual Engine Start Unit with Protection
Description Code Delivery £
CROMPTON
Engine cranking controlAutomatic shutdown on fault condition KEY-START-ETM A 70.50Pre-heat capabilityEngine cranking controlAutomatic shutdown on fault conditionPre-heat capability KEY-START-ETM-ALT A 89.00Over-speed sensing via alternator inputTachometer outputEngine cranking controlAutomatic shutdown on fault conditionPre-heat capability KEY-START-ETM-MAG A 87.00Over-speed sensing via magnetic pickup input Tachometer outputSpare keys set of 2 KEYS-KS A 15.00
KEY-START DIN72 Manual Engine Start Unit with Elapsed Time Meter and Protection
Description Code Delivery £
CROMPTON
Engine cranking controlAutomatic shutdown on fault conditionStop button, two programmable KEY-START-STOP A 70.50Shutdown/warning inputsPre-heat capabilityEngine cranking controlAutomatic shutdown on fault conditionStop button, two programmable Shutdown/warning inputs KEY-START-STOP-ALT A 93.00Pre-heat capabilityOver-speed sensing via alternator inputTachometer outputEngine cranking controlAutomatic shutdown on fault conditionStop button, two programmable Shutdown/warning inputs KEY-START-STOP-MAG A 93.00Pre-heat capability, over-speed sensingvia magnetic pickup input, Tachometer outputSpare keys set of 2 KEYS-KS A 15.00
KEY-START-STOP DIN72 Manual Engine Start Unit with Stop Button and Protection
A range of multifunction products designed specifically to meet the exactingstandards required by OEM specification. The range offers the generatorset manufacturer and panel builder space saving and cost effectivealternatives to traditional analogue meters, relays, timers and switches.
To suit the requirements of combined heat and power, co-generation, dieseland gas engine generator applications, the Generator Set Controller rangeoffers products for basic levels of control, through to sophisticatedmultifunctional products offering automated engine starting, stopping,transfer switching, protection, control and metering.
45
Description Code Delivery £
CROMPTON
Engine cranking controlAutomatic shutdown on fault conditionRemote fuel on and remote start inputs GEN-KEY-12V A 104.00Pre-heat capability12 volt systemEngine cranking controlAutomatic shutdown on fault conditionRemote fuel on and remote start inputs GEN-KEY-24V A 104.00Pre-heat capability24 volt systemSpare keys set of 2 KEYS-GK A 15.00
GEN-KEY DIN96 Key Operated Automatic Start Unit
Description Code Delivery £
CROMPTON
Engine cranking controlGenerator voltage meteringGenerator frequency meteringEngine cool downEngine RPM metering GEN-AUTO A 184.50Engine run time meteringBattery voltage meteringEngine maintenance monitoring
GEN-AUTO DIN96 Automatic Start Unit with Metering
Description Code Delivery £
CROMPTON
Engine cranking controlGenerator voltage meteringGenerator frequency meteringGenerator load current and kVA meteringEngine cool down GEN-AUTOXM A 208.00Engine RPM meteringEngine run time meteringBattery voltage meteringEngine maintenance monitoring
GEN-AUTO DIN96 Automatic Start Unit with Advanced Metering
Description Code Delivery £
CROMPTON
Engine cranking controlGenerator voltage metering 3-phaseGenerator frequency meteringGenerator load current 1-phaseGenerator kVA meteringEngine cool downEngine RPM metering GEN-AUTOEN A 215.00Engine oil pressure meteringEngine temperature meteringEngine run time meteringFuel level meteringBattery voltage meteringEngine maintenance monitoring
GEN-AUTO DIN96 Automatic Start Unit with Engine Metering
Description Code Delivery £
CROMPTON
Engine cranking controlAutomatic shutdown on fault condition, KEY-START-ETM- A 70.50stop button, Two programmable STOPshutdown/warning inputs Pre-heat capabilityEngine cranking control Automatic shutdown on fault condition, stop button Two programmable shutdown/ KEY-START-ETM- A 93.00warning inputs Pre-heat capability, over-speed STOP-ALTsensing via alternator input, Tachometer outputEngine cranking controlAutomatic shutdown on fault condition, stop button Two programmable shutdown/ KEY-START-ETM- A 93.00warning inputs Pre-heat capability, over-speed STOP-MAGsensing via magnetic pickup input, Tachometer outputSpare keys set of 2 KEYS-KS A 15.00
KEY-START DIN72 Manual Engine Start Unit with Elapsed Time Meter,
Stop Button and Protection
46
Description Code Delivery £
CROMPTON
Engine cranking control AGenerator voltage metering 3-phase AGenerator frequency metering AGenerator load current 3-phase AGenerator kVA metering AEngine cool down AEngine RPM metering GEN-AUTOFP C 190.00Engine oil pressure metering (50/60Hz) CEngine temperature metering CEngine run time metering GEN-AUTOGP C 215.00Fuel level metering (400Hz) CBattery voltage metering CEngine maintenance monitoring C
GEN-AUTO DIN204 x 144 Automatic Start Unit with Advanced Metering
and Engine Metering
Description Code Delivery £
CROMPTON
Automatic engine start, stop and load transferManual engine start/stopManual load transferringGenerator no load testMains voltage metering 3-phase GEN-TRANS A 231.00Generator voltage metering Generator frequency meteringEngine cranking controlEngine cool downEngine run time meteringBattery voltage metering
GEN-TRANS DIN96 Automatic Transfer Switch with Display and
Relay Outputs
Description Code Delivery £
CROMPTON
Automatic engine start, stop and load transferManual engine start/stopManual load transferringGenerator no load testMains voltage metering 3-phaseGenerator voltage metering GEN-XFER A 190.00Generator frequency meteringEngine cranking controlEngine cool downEngine run time meteringBattery voltage metering
GEN-TRANS DIN204 x 144 Automatic Transfer Switch with Display and
Transistor Outputs
GEN-TRANS DIN204 x 144 Automatic Transfer Switch with
Transistor Outputs (No Display)
Description Code Delivery £
CROMPTON
Automatic engine start, stop and load transferManual engine start/stopManual load transferringGenerator no load testMains voltage supervision GEN-XFERND A 145.00Generator voltage protectionGenerator frequency protectionEngine cranking controlEngine cool downEngine run time supervisionBattery voltage supervision
PC Communication and Programming
Description Code Delivery £
CROMPTON
Configuring and monitoring software PC Windows style user interfaceAllows the user to load and save configuration to and from a hard discAllows the user to send and retrieve configuration settings to and from the GEN-SOFT A 25.00generator set controllerSuitable for use with GEN-AUTO, GEN-AUTO XM, GEN-AUTO EN, GEN-AUTO FP, GEN-TRANS, GEN-XFER, and GEN-XFER NDCost includes registration and free updates
Configurable Annunciator Unit
Description Code Delivery £
CROMPTON
10 configurable inputs(Failures or status signal)5 configurable control inputs6 configurable relay inputs GEN-ANNUN A 282.00 Failure reset. Lamp test and hornsilence functionsRS232 communication
47
49
Tyco Electronics under its Bowthorpe EMP brand specializes in low voltagetransient surge suppression, protecting against the secondary impacts fromlightning strikes and switching electrical conductive loads.
Bowthorpe EMP protection starts where power and communication lines firstenter a building and continues with devices designed for the specific needs ofall equipment and electronics within those four walls.
Snap-in protection module - SPM seriesSurge protected filter adaptors, plug protectorsModular distribution surge protector - MDSP 90, 150 and 300 Series Distribution surge protector - DSP600 series Mains barrier surge protector - MBP series Spur protector - SPLB1/13
To find out more, please contact our sales teamTel: 0870 870 7500 Fax: 0870 240 5287or Email: [email protected] • www.energy.tycoelectronics.comTyco and Bowthorpe EMP are a trademarks
Prepared for a surge?
ENERGY DIVISION
© Tyco Electronics CI-EPP-UK-CATALIST-01/07
All of the above information, including drawings, illustrations and graphic designs, reflects our present understandingand is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate thesuitability of each product for the desired application. Under no circumstances does this constitute an assurance of anyparticular quality or performance. Such an assurance is only provided in the context of our product specifications orexplicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions ofsale. CROMPTON is a trademark of Crompton Parkinson Ltd. and is used by Tyco Electronics under licence.
Energy Division – economical solutions for the electrical power industry: cableaccessories, connectors & fittings, electrical equipment, instruments, lighting controls,insulators & insulation enhancement and surge arresters.
Tyco Electronics UK Limited, Crompton InstrumentsFreebournes Road, Witham, Essex, CM8 3AH, UKPhone: +44 (0) 870 870 7500 Fax: +44 (0) 870 240 5287www.crompton-instruments.com
a vital part of your world