1
est. 1912 -HF Change-HF Cross Section We know total safety is important to you and protecting your people in an HF-Alky service is priority one! This is why we have designed the Change-HF ™. This gasket is the superior choice in HF-Alky service. The Change-HF ™ protects and outperforms every other HF-Alky gasket on the market . Change-HF Installed in a Corroded Flange Change HF Cross Section Change HF Installed in a Corroded Flange Why does it work so well? Why does it work so well? > Flexibility of a proven spiral wound, low seating stress of a kammpro > Graphite filled like a spiral wound, graphite faced like a kammpro > Sigma PTFE inner ring barrier protects the flange from acid corrosion and also fills any existing corrosion damage > Unique wire profile stores more elastic energy to create better dynamic performance and superior load retention in cyclic applications > Excellent recovery (tested with 34% recovery @ 18K PSI [124 MPa], 30% compression) > No spring washers needed, n o r e - t o r q u e r e q u i r e d * > Cycle over & over, and m a i n t a i n s e a l a b i l i t y THAT’S SAFE. Ask about our successful full plant conversion for a major national refiner who has switched all of their HF-Alky Gaskets to the Change-HF ™ . Proven to work. T h e r m a l C y c l e T e s t - 2 4 C y c l e s Flexitallic US, LLC 6915 HWY 225 Deer Park, TX 77536 ●flexitallic.com 281-604-2400 *100% gasket stress retenon achieved under EN13555 relaxaon test. Contact us: [email protected] Pressure vs Cycle

Change-HF Flyer 05-15-2019 · 2020-04-05 · est. 1912-HF ™ Change-HF ™ Cross Section We know total safety is important to you and protecting your people in an HF-Alky service

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Change-HF Flyer 05-15-2019 · 2020-04-05 · est. 1912-HF ™ Change-HF ™ Cross Section We know total safety is important to you and protecting your people in an HF-Alky service

est. 1912

-HF™

Change-HF ™ Cross Section

We know total safety is important to you and protecting your people in an HF-Alky service is

priority one! This is why we have designed the Change-HF ™. This gasket is the superior choice in

HF-Alky service. The Change-HF ™ protects and outperforms every other HF-Alky gasket onthe market .

Change-HF ™ Installed in a Corroded FlangeChange HF Cross Section Change HF Installed in a Corroded Flange

Why does it work so well?Why does it work so well?> Flexibility of a proven spiral wound, low seating stress of a kammpro> Graphite filled like a spiral wound, graphite faced like a kammpro

> Sigma PTFE inner ring barrier protects the flange from acid corrosion andalso fills any existing corrosion damagey g g

> Unique wire profile stores more elastic energy to create better dynamicperformance and superior load retention in cyclic applications

> Excellent recovery (tested with 34% recovery @ 18K PSI [124 MPa], 30% compression)

> No spring washers needed, no re-torque required*> Cycle over & over, and maintain sealability

…THAT’S SAFE.Ask about our successful full plant conversion for amajor national refiner who has switched all of theirHF-Alky Gaskets to the Change-HF ™ .

Proven to work.

Thermal Cycle Test- 24 Cycles

Flexitallic US, LLC ● 6915 HWY 225 Deer Park, TX 77536 ● flexitallic.com ● 281-604-2400*100% gasket stress retention achieved under EN13555 relaxation test.

Contact us: [email protected]

Pressure vs Cycle