MADE IN USA 100 School Street, Bergenfield, NJ 07621 Phone: (201) 385 - 0500 Fax: (201) 385 - 0702 NOVA ELECT RIC Leader in power conversion technology since 1966 [email protected] www.novaelectric.com AS 9100 Certificate No: US008267-1 AS 9100 Certificate No: US008267-1 1U 2U 3U 5U RUGGED RACK MOUNT AC TO AC FREQUENCY CONVERTERS 50 Hz 60 Hz 400 Hz - SINGLE OR 3 PHASE INPUT ACTIVE POWER FACTOR CORRECTION MIL-SPEC COMPLIANT 900 VA - 5 KVA SINGLE PHASE 375 VA - 10.5 KVA THREE PHASE NOTE: (1) May require external EMI Filter. (2) Requires external shock absorbers. OPTIONAL COMPLIANCES BY DESIGN OR TEST MIL-STD-810 MIL-STD-1399 MIL-STD-461 (1) MIL-STD-167 MIL-STD-704 MIL-S-901D (2) DO-160 APPLICATIONS Shelters Taccal Systems Shipboard Power HMMWVs Mobile Systems Ground Support Aircraſt

Certi˜cate No: US008267-1 - Nova ElectricCerti˜cate No: US008267-1 1U 2U 3U 5U RUGGED RACK MOUNT AC TO AC FREQUENCY CONVERTERS 50 Hz 60 Hz 400 Hz - SINGLE OR 3 PHASE INPUT ACTIVE

  • Upload
    others

  • View
    13

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Certi˜cate No: US008267-1 - Nova ElectricCerti˜cate No: US008267-1 1U 2U 3U 5U RUGGED RACK MOUNT AC TO AC FREQUENCY CONVERTERS 50 Hz 60 Hz 400 Hz - SINGLE OR 3 PHASE INPUT ACTIVE

MADE IN USA100 School Street, Bergen�eld, NJ 07621 • Phone: (201) 385 - 0500 Fax: (201) 385 - 0702NOVA ELEC T RIC Leader in power conversion technology since 1966

[email protected] www.novaelectric.com AS 9100

Certi�cate No: US008267-1

AS 9100

Certi�cate No: US008267-1

1U

2U

3U

5U

RUGGED RACK MOUNTAC TO AC FREQUENCY CONVERTERS 50 Hz 60 Hz 400 Hz - SINGLE OR 3 PHASEINPUT ACTIVE POWER FACTOR CORRECTION

MIL-SPEC COMPLIANT900 VA - 5 KVA SINGLE PHASE

375 VA - 10.5 KVA THREE PHASE

NOTE: (1) May require external EMI Filter. (2) Requires external shock absorbers.

OPTIONAL COMPLIANCESBY DESIGN OR TESTMIL-STD-810MIL-STD-1399MIL-STD-461 (1)

MIL-STD-167MIL-STD-704MIL-S-901D (2)

DO-160

APPLICATIONSSheltersTactical SystemsShipboard PowerHMMWVsMobile SystemsGround SupportAircraft

Page 2: Certi˜cate No: US008267-1 - Nova ElectricCerti˜cate No: US008267-1 1U 2U 3U 5U RUGGED RACK MOUNT AC TO AC FREQUENCY CONVERTERS 50 Hz 60 Hz 400 Hz - SINGLE OR 3 PHASE INPUT ACTIVE

MADE IN USA100 School Street, Bergen�eld, NJ 07621 • Phone: (201) 385 - 0500 Fax: (201) 385 - 0702NOVA ELEC T RIC Leader in power conversion technology since 1966

[email protected] www.novaelectric.comAS 9100

Certi�cate No: US008267-1MADE IN USA100 School Street, Bergen�eld, NJ 07621 • Phone: (201) 385 - 0500 Fax: (201) 385 - 0702NOVA ELEC T RIC Leader in power conversion technology since 1966

[email protected] www.novaelectric.com AS 9100

Certi�cate No: US008267-1

FEATURES• Crystal Controlled Frequency• Compact and light weight, yet rugged and vehicle rated. • 80-88% efficient. • Tightly regulated output voltage and freq. • Able to supply inrush current.• Factory set to 50 Hz, 60 Hz or 400 Hz output. • Capable of driving highly reactive loads • Capable of driving highly capacitive loads such as non PFC switching power supplies. • Very low harmonic distortion, THD<3%. • Suitable for vehicle mounting. • Fan cooled with air filter.

ELECTRICALInput Voltage (select): See TableOutput Voltage (select): See TableOutput Frequency: 50 Hz, 60 Hz or 400 HzOverload: 125% for 5 minutesOutput Waveform Sinewave: <3% THD Output Regulation: ± 2.5% MTBF: over 100,000 hours per field dataMTTR: 30 minutesEMI: per MIL-STD-461E or F (Note 1)

PROTECTIVE FEATURES• Overload• Overvoltage• Overtemperature

ENVIRONMENTALOperating Temperature: -20°C to +50°C Storage Temperature: -40°C to + 85°C Shock: 20g / 11 mS per MIL-STD-810Vibration: per MIL-STD-810 for Airborne or Surface Vehicle and MIL-STD-167 ShipboardHumidity: per MIL-STD-810 to 95% non condensing

POPULAR OPTIONS• MS Connector and Mates• Chassis Slides• Internal Electromechanical Transfer Switch• EMI Filter (Input or Output)• SNMP• Remote ON/OFF• Output Inhibit• Input and Output Circuit Breakers• Circuit Breaker Guards

APPLICATIONSThe NGFCPFCRK frequency converters are intended for industrial and military applications where DC voltage needs to be converted to 50 Hz, 60 Hz or 400 Hz, 3Ø. These frequency converters are used for running electronic loads such as computers, monitors, printers, telecom systems and radios derived from utility or field generators. They can also be used for hand tools & motors. These units can be further ruggedized for military grade shock, vibration, temperature and humidity. Utilizing field proven technology, this series of rack mount rugged frequency converters is suitable for harsh environments and can be optionally customized for unique sizes and shapes. The output is either single phase or three phase, four wire WYE with and a neutral line. It can work with totally unbalanced three phase loads.

q MILITARY SHELTERS q GROUND SUPPORT q MOBILE SYSTEMS

q TACTICAL SYSTEMS q SHIP APPLICATIONS q COMMUNICATIONS

1U

2U

3U

5U

AVIONIC AUTOMATIC TEST EQUIPMENT SYSTEM

Note:1. EMI Compliance will require additional internal or external EMI filtering, specify requirements.

Note:All images are for reference only. Actual product may be somewhat different.

Input Power Factor CorrectedRack Mount Frequency Converters for

Naval • Ground • Airborne Applications

Page 3: Certi˜cate No: US008267-1 - Nova ElectricCerti˜cate No: US008267-1 1U 2U 3U 5U RUGGED RACK MOUNT AC TO AC FREQUENCY CONVERTERS 50 Hz 60 Hz 400 Hz - SINGLE OR 3 PHASE INPUT ACTIVE

MADE IN USA100 School Street, Bergen�eld, NJ 07621 • Phone: (201) 385 - 0500 Fax: (201) 385 - 0702NOVA ELEC T RIC Leader in power conversion technology since 1966

[email protected] www.novaelectric.comAS 9100

Certi�cate No: US008267-1MADE IN USA100 School Street, Bergen�eld, NJ 07621 • Phone: (201) 385 - 0500 Fax: (201) 385 - 0702NOVA ELEC T RIC Leader in power conversion technology since 1966

[email protected] www.novaelectric.com AS 9100

Certi�cate No: US008267-1

Input Power Factor CorrectedRack Mount Frequency Converters for

Naval • Ground • Airborne Applications

MODEL SELECTION

NGFCPFCRK 0.3K3 / 60 - Y115/200 - 120/208

Inverter Style Output Power KVA, 3 Phase Output FrequencySelection

Input VoltageSelection

Output VoltageSelection

NGFCPFCRK0K3 /000-000/000-000/0001 2 43

Partial Three Phase Model Selection

MODEL

1. See “XX” in Model SelectionK VA/KW

OUTPUT FREQ.(Hz)

2. See “YYY” in Model

NOMINAL INPUT(VAC)

3. See “ZZZ/ZZZ” in Model

OUTPUT VOLTAGE(VAC)

4. See “QQQ/QQQ” in Model

WEIGHT

(Lb. / Kg.)

DIMENSIONS

( H x W x L - Inch & [cm] )

NGFCPFCRK0.3K3/X-YYY-ZZZ/ZZZ 0.375 KVA0.3 KW Select:

50 | 60 | 400

Specialty frequencies also

available.

Consult Factory.

Select:

Y 115/200Y 120/208Y 240V L-N

∆ 208V L-L ∆ 230V L-L∆ 240V L-L

Specialty inputs also available.Consult Factory.

Select:

115/200 | 120/208

220/380 | 230/400

240/415

Specialty outputs also available.

Consult Factory.

26 lb12 kg

1.75” x 19” x 24”[4.45 x 48.26 x 60.96]

NGFCPFCRK3K3X-YYY-ZZZ/ZZZ 3KVA2.4 KW

35 lb16 kg

3.5” x 19” x 24”[8.89 x 48.26 x 60.96]

NGFCPFCRK5K3/X-YYY-ZZZ/ZZZ 4.5 KVA3.6 KW

46 lb21 kg

8.75” x 19” x 24”[22.23 x 48.26 x 60.96]

NGFCPFCRK6K3/X-YYY-ZZZ/ZZZ 6 KVA4.8 KW

60 lb27 kg

8.75” x 19” x 24”[22.23 x 48.26 x 60.96]

NGFCPFCRK9K3/X-YYY-ZZZ/ZZZ 10.5 KVA8.4 KW

60 lb27 kg

8.75” x 19” x 24”[22.23 x 48.26 x 60.96]

{

1U

2U

3U

5U

{ X Y Y Y Q Q Q

Note: For custom shapes and sizes contact factory at (201) 385 - 0500

Example 3Ø Model Selection:

GLFCPFC - 1K 60 - 120/240 - 115

Inverter Style Output Power KVA Output FrequencySelection Nominal Input Voltage Output Voltage

Selection

Example 1Ø Model Selection:

GLFCPFC-00K000-120/240-0001 2 3

{ Y Y Y Z Z Z { X X {

Single Phase Model Selection

MODEL

1. See “XX” in Model SelectionK VA/KW

OUTPUT FREQ.(Hz)

2. See “YYY” in Model

NOMINAL INPUT(VAC)

OUTPUT VOLTAGE(VAC)

3. See “ZZZ” in Model

WEIGHT

(Lb. / Kg.)

DIMENSIONS

( H x W x L - Inch & [cm] )

GLFCPFC-1KYYY-120/240-ZZZ 0.9 KVA0.7 KW

Select:

50 | 60 | 400

Specialty frequencies also available.

Consult Factory.

120/240 V

Specialty inputs also available.

Consult Factory.

Select:

115 | 120 | 220

230 | 240

Specialty outputs also available.

Consult Factory.

25 lb11.3 kg

1.75” x 19” x 22”[4.45 x 48.26 x 55.88]

GLFCPFC-1.5KYYY-120/240-ZZZ 1.5 KVA1.2 KW

30 lb13.6 kg

3.5” x 19” x 24”[8.89 x 48.26 x 60.96]

GLFCPFC-2KYYY-120/240-ZZZ 2 KVA1.6 KW

40 lb18.1 kg

5.25” x 19” x 24”[13.34 x 48.26 x 60.96]

GLFCPFC-3KYYY-120/240-ZZZ 3 KVA2.4 KW

40 lb18.1 kg

5.25” x 19” x 24”[13.34 x 48.26 x 60.96]

GLFCPFC-3KYYY-120/240-ZZZ 3 KVA3 KW

42 lb19.1 kg

7” x 19” x 24”[17.78 x 48.26 x 60.96]

GLFCPFC-5KYYY-120/240-ZZZ 5 KVA4 KW

45 lb20.4 kg

7” x 19” x 24”[17.78 x 48.26 x 60.96]

Z Z Z Q Q Q { Z Z Z {

Page 4: Certi˜cate No: US008267-1 - Nova ElectricCerti˜cate No: US008267-1 1U 2U 3U 5U RUGGED RACK MOUNT AC TO AC FREQUENCY CONVERTERS 50 Hz 60 Hz 400 Hz - SINGLE OR 3 PHASE INPUT ACTIVE

MADE IN USA100 School Street, Bergen�eld, NJ 07621 • Phone: (201) 385 - 0500 Fax: (201) 385 - 0702NOVA ELEC T RIC Leader in power conversion technology since 1966

[email protected] www.novaelectric.comAS 9100

Certi�cate No: US008267-1MADE IN USA100 School Street, Bergen�eld, NJ 07621 • Phone: (201) 385 - 0500 Fax: (201) 385 - 0702NOVA ELEC T RIC Leader in power conversion technology since 1966

[email protected] www.novaelectric.com AS 9100

Certi�cate No: US008267-1

Input Power Factor CorrectedRack Mount Frequency Converters for

Naval • Ground • Airborne Applications

OUTLINE DRAWING

DISCLAIMERExcept where otherwise noted or superseded by process of law, Nova Electric accepts no responsibility or liability for any losses or damages of any kind arising out of the use of this catalog or any of its related functions.

WARRANTYAll products of Nova Electric are warrantied for one year parts and labor. Repair is done at the Nova Electric service department.

TYPICAL FRONT VIEW

TYPICAL REAR VIEW

TYPICAL LEFT SIDE VIEW

TYPICAL TOP VIEW

FREQUENCY CONVERTER

24.00”(22.00” - 1U)

16.8

6”

19.00”

A

PANEL SIZE DIMENSION

1U A = 1.75”

2U A = 3.50"

3U A = 5.25”

4U A = 7.00”

5U A = 8.75”

( )

( )

NOTES:1. ALL UNIDIMENSIONED PICTORIAL CONFIGURATIONS ARE FOR REFERENCE ONLY2. FRONT AND REAR MARKINGS FOR REFERENCE ONLY3. REFER TO WEBSITE FOR ACTUAL DRAWINGS

7.00

3.00”

1U PROFILEHAS STEP HERE

NGLFCRK4PG2017.A