119
OMNI-Test Laboratories, Inc. EPA Standard of Performance for New Residential Wood Heaters Certification Test Report Non-Confidential Business Information (Non-CBI) Manufacturer: Travis Industries, Inc. Heater Type: Pellet-Fired, Freestanding Model: AGP PS Prepared for: Travis Industries, Inc. 12521 Harbour Reach Drive Mukilteo, WA 98275 USA Prepared by: OMNI-Test Laboratories, Inc. 13327 NE Airport Way Portland, OR 97230 (503) 643-3788 Test Period: August 29, 2018 Report Date: October 5, 2018 Report Number: 0028PS018E All data and information contained in this report are confidential and proprietary to Travis Industries. Its significance is subject to the adequacy and representative character of the samples and to the comprehensiveness of the tests, examinations, or surveys made. The contents of this report cannot be copied or quoted, except in full, without specific, written authorization from Travis Industries and OMNI-Test Laboratories, Inc. No use of the OMNI-Test Laboratories, Inc. name, logo, or registered mark (O-TL) is permitted, except as expressly authorized by OMNI-Test Laboratories, Inc. in writing. - Document Edition # 001 -

Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc.

EPA Standard of Performance for New Residential Wood Heaters

Certification Test Report

Non-Confidential Business Information (Non-CBI)

Manufacturer: Travis Industries, Inc.

Heater Type: Pellet-Fired, Freestanding

Model: AGP PS

Prepared for: Travis Industries, Inc.

12521 Harbour Reach Drive Mukilteo, WA 98275 USA

Prepared by: OMNI-Test Laboratories, Inc. 13327 NE Airport Way Portland, OR 97230 (503) 643-3788 Test Period: August 29, 2018 Report Date: October 5, 2018 Report Number: 0028PS018E All data and information contained in this report are confidential and proprietary to Travis Industries. Its significance is subject to the adequacy and representative character of the samples and to the comprehensiveness of the tests, examinations, or surveys made. The contents of this report cannot be copied or quoted, except in full, without specific, written authorization from Travis Industries and OMNI-Test Laboratories, Inc. No use of the OMNI-Test Laboratories, Inc. name, logo, or registered mark (O-TL) is permitted, except as expressly authorized by OMNI-Test Laboratories, Inc. in writing.

- Document Edition # 001 -

Page 2: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E

OMNI-Test Laboratories, Inc.

AUTHORIZED SIGNATORIES This report has been reviewed and approved by the following authorized signatories: Evaluator: ___________________________

Aaron Kravitz OMNI-Test Laboratories, Inc. QA Review: ___________________________

Ken Morgan OMNI-Test Laboratories, Inc. ______________ Issue Date

Page 3: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E

OMNI-Test Laboratories, Inc.

TABLE OF CONTENTS PREFACE ................................................................................................................ (3 pages) Section 1 –Appliance, Testing, & Results ............................................................................. 4

1.1 Summary Tables ............................................................................................................. 5

Table 1 – Particulate Emissions ................................................................................. 5 Table 2 – Efficiency and CO ....................................................................................... 5 Table 3 – Test Facility Conditions ............................................................................ 6 Table 4 – Heater Configuration ................................................................................ 6

1.2 Procedures & Results Summary..................................................................................... 7

1.3 Appliance Description............... .................................................................................... 8

Section 2 – Test Data ................................................................................................................ 11

2.1 Test Data by Run .......................................................................................................... 12

2.2 Sample Analysis & Tares ............................................................................................. 29

Section 3 –Laboratory Quality Assurance ......................................................................... 36

3.1 Quality Assurance/Quality Control ............................................................................. 37

3.2 Calibration Data ........................................................................................................... 38

3.3 Example Calculations .................................................................................................. 54

Appendix A – Labeling & Owner’s Manual

Page 4: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E

OMNI-Test Laboratories, Inc.

Section 1 Appliance, Testing, & Results

1.1 - Summary Tables 1.2 – Procedures and Results Summary 1.3 - Appliance Description

Page 4 of 68

Page 5: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E

OMNI-Test Laboratories, Inc.

1.1 - Summary Tables

Table 1 – Particulate Emissions

One-Hour Filter Integrated Total

Emission Rate (g/hr)

8.203 1.801

Emission Factor (g/dry kg)

3.617 1.663

Table 2 – Efficiency and CO

Burn Rate Segment Integrated Total Maximum Medium Minimum

Time (minutes)

60 120 180 360

Burn Rate (dry kg/hr)

2.269 1.112 0.669 1.083

Heat Input Rate (BTU/hr, HHV)

43,428 21,296 12,806 20,740

Heat Output Rate (BTU/hr, HHV)

34,738 15,937 8,959 15,677

Efficiency (%, HHV)

80.0% 74.8% 70.0% 75.6%

Efficiency (%, LHV)

85.5% 80.0% 74.8% 80.8%

CO Emission Rate (g/min)

1.21 0.12 0.15 0.31

Page 5 of 68

Page 6: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E

OMNI-Test Laboratories, Inc.

1.1 - Summary Tables

Table 3 – Test Facility Conditions

Initial Middle Final

Room Temperature (°F)

74 78 76

Barometric Pressure (in Hg)

29.36 29.37 29.37

Air Velocity (ft/min)

<50 <50 <50

Induced Draft (in H2O)

Φ Φ Φ

Table 4 – Heater Configuration

Pretest

Burn Rate Segment

Maximum Medium Minimum

Heat Output Setting Dial Max Dial Max Dial @ 6 of 14 Dial Min

Fan Setting Max Max Max Max

Medium Heat Settings:

Page 6 of 68

Page 7: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E

OMNI-Test Laboratories, Inc.

1.2 - Procedures and Results Summary TESTING PROCEDURE The AGP PS was tested in accordance with the U.S. EPA 40 CFR Part 60, Subpart AAA – Standards of Performance for New Residential Wood Heaters using ASTM E2515 and ASTM E2779. The fuel used for certification testing was Bear Mountain brand densified wood pellet fuel; this fuel was graded as Premium by the Pellet Fuels Institute and was produced at registered mill # 03541. Particulate emissions were measured using dual sampling trains consisting of two sets of filters (front and back). A single test run was performed. The unit was installed and adjusted in accordance with the manufacturer’s instructions, adjusting an air inlet slide to the fully out position. This slide was fixed in place throughout the integrated test run. The manufacturer’s instructions specified leaving the fan on the maximum dial setting (fixed stop) throughout the run, and operating the preburn and high burn segments at maximum heat dial setting (fixed stop), the medium burn segment at heat dial setting 6 of 14 (see photo in table 4), and the low burn segment at the minimum heat dial setting (fixed stop). These settings were used for the test run, as specified. RESULTS SUMMARY Proportionality results of the integrated test run, in addition to all other validity criteria, were within specified limits, and no sampling anomalies occurred. All burn rate categories were achieved. Therefore, this test run is considered valid. The results of the integrated test run indicate an average particulate emission rate of 1.80 g/hr. The AGP PS results are within the emission limit of 2.0 g/hr for affected appliances manufactured or sold at retail on or after May 15, 2020. The model AGP PS was tested for thermal efficiency and carbon monoxide (CO) emissions in accordance with CSA B415.1-10. The heater has a demonstrated an average thermal efficiency of 75.6%. The calculated CO emission rate was 0.31 g/min. Upon completion of emissions certification testing, the sample unit was sealed and will be stored by the manufacturer in accordance with the requirements of the CFR.

Page 7 of 68

Page 8: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E

OMNI-Test Laboratories, Inc.

1.3 - Appliance Description Appliance Manufacturer: Travis Industries Pellet Stove Model: AGP PS Type: Freestanding, air-circulating type, pellet-fired room heater. The AGP PS’s principle elements include a fuel hopper, stainless-steel firebox chamber, stainless steel burn pot, and electrical fuel feed, combustion air, and convection air supply systems. The frame of the unit is constructed of mild steel, as is the outer fascia. Combustion products are routed out of the firebox chamber via a baffle-type heat exchanger through a 3-inch diameter flue outlet located on the rear of the unit. Fuel is supplied from the hopper to the burn pot via a screw-type auger, mounted horizontally. Fuel supply rate is varied by cycling the auger motor as needed. Ashes fall through the burn pot into a removable ash drawer located at the bottom of the unit. The drawer is accessed through a mild steel door, distinct from the cast aluminum front firebox door, which also features a 15.5” x 10.25” glass panel. The electrical systems are regulated by user-operated dials for the heat setting and convection fan. Both dials have fixed maximum and minimum stops, with 14 demarcations in between. The unit can also be controlled by an external thermostat system. More detailed information is shown in the manufacturer’s design drawings, Appendix C of this report. This information is considered confidential business information (CBI) by the manufacturer and is not included in the non-CBI version of this report.

AGP PS – Sealed Test Unit

Page 8 of 68

Page 9: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E

OMNI-Test Laboratories, Inc.

Appliance Photographs AGP PS

Test Date: 8/30/2018

AGP PS Front AGP PS Back

AGP PS Left AGP PS Right

Page 9 of 68

Page 10: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E

OMNI-Test Laboratories, Inc.

Section 2 Test Data

2.1 Test Data by Run

2.2 Sample Analysis & Tares

Page 10 of 68

Page 11: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E

OMNI-Test Laboratories, Inc.

2.1 - Test Data by Run

Run 1 Notes & Results (1-minute intervals)

Page 11 of 68

Page 12: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc

ASTM E2779 / ASTM E2515 Emissions Results

Manufacturer: Travis

Model: AGP PS

Project No.: 0028PS108E

Tracking No.: 2308

Run: 1 Technician Signature:

Test Date:

Integrated Test Run

Particulate Emission Rate 1.80 g/hr

Total Particulate Emissions - ET 10.81 g

Emissisons Factor 1.66 g/kg

CSA B415 Efficiency 75.6% HHV

First Hour Emissions

Particulate Emission Rate 8.20 g/hr

Total Particulate Emissions - ET 8.20 g

Emissisons Factor 3.62 g/kg

Burn Rate (Composite) 1.08 kg/hr dry

Burn Rate (High) 2.27 kg/hr dry

Burn Rate (Medium) 1.11 kg/hr dry 49.0% Of High

Burn Rate (Low) 0.67 kg/hr dry 29.5% Of High

Average Tunnel Temperature 82 degrees F

Avg.Velocity in Dilution Tunnel - vs 14.22 ft/second

Avg.Flow Rate in Dilution Tunnel - Qsd 9409.7 dscf/hour

Average ∆p 0.050 inches H20

Average ∆H 1.81 inches H20

Total Time of Test 360 minutes

08/29/18

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Emissions Results

Page 12 of 68

Page 13: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc

ASTM E2779 / ASTM E2515 Emissions Results

Manufacturer: Travis

Model: AGP PS

Project No.: 0028PS108E

Tracking No.: 2308

Run: 1 Technician Signature:

Test Date: 08/29/18

1st Hour Sample Train 1 Sample Train 2

Ambient

Sample Unit

Total Sample Volume - Vm 8.809 52.944 52.870 0.000 ft3

Average Gas Meter Temperature 78.43 79.72 79.54 77 °F

Sample Volume (Std. Conditions) - Vmstd 8.488 50.893 49.955 0.000 dsf3

N/A

Total Particulates - mn 7.4 9.7 9.6 0 mg

Particulate Concentration - Cr/Cs 8.718E-04 1.91E-04 1.92E-04 0.00E+00 g/dsf3

Total Particulate Emissions - ET 8.20 10.76 10.85 0.00 g

Particulate Emission Rate 8.20 1.79 1.81 0.00 g/hr

Emissisons Factor 3.62 1.66 1.67 g/kg

Delta from Avg. Particulate Emissions 0.04 0.04 g

Quality Checks

Filter Temps < 90 °F OK Ambient Temp (55-90°F) OK

Filter Face Velocity OK Negative Probe Weight OK

Leakage Rate OK Pro-Rate Variation OK

Medium Burn Rate < 50% OK Dual Train Comparison OK

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Emissions Results

Page 13 of 68

Page 14: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc

CSA B415.1 Results - Overall & By CategoryManufacturer: Travis Run: 1

Model: AGP PS Control #: 0028PS108E

Date: Test Duration: 360

HHV Basis LHV Basis HHV Basis LHV Basis

Overall Efficiency 75.6% 80.8% Overall Efficiency 80.0% 85.5%

Combustion Efficiency 99.5% 99.5% Combustion Efficiency 98.1% 98.1%

Heat Transfer Efficiency 76% 81.2% Heat Transfer Efficiency 82% 87.2%

Output Rate (kJ/h) 16,526 15,677 (Btu/h) Output Rate (kJ/h) 36,620 34,738 (Btu/h)

Burn Rate (kg/h) 1.08 2.39 (lb/h) Burn Rate (kg/h) 2.27 5.00 (lb/h)

Input (kJ/h) 21,863 20,740 (Btu/h) Input (kJ/h) 45,781 43,428 (Btu/h)

Test Load Weight (dry kg) 6.50 14.33 dry lb Test Load Weight (dry kg) 2.27 5.00 dry lb

MC wet (%) 3.85 MC wet (%) 3.85

MC dry (%) 4.00 MC dry (%) 4.00

Particulate (g ) 10.81 Particulate (g ) 7.40

CO (g) 111 CO (g) 73

Test Duration (h) 6.00 Test Duration (h) 1.00

Emissions Particulate CO Emissions Particulate CO

g/MJ Output 0.11 1.12 g/MJ Output 0.20 1.99

g/kg Dry Fuel 1.66 17.02 g/kg Dry Fuel 3.26 32.09

g/h 1.80 18.44 g/h 7.40 72.79

lb/MM Btu Output 0.25 2.59 lb/MM Btu Output 0.47 4.62

Air/Fuel Ratio (A/F) 32.63 Air/Fuel Ratio (A/F) 14.53

HHV Basis LHV Basis HHV Basis LHV Basis

Overall Efficiency 74.8% 99.5% Overall Efficiency 70.0% 99.5%

Combustion Efficiency 99.5% 80.4% Combustion Efficiency 99.5% 75.2%

Heat Transfer Efficiency 75% 80.4% Heat Transfer Efficiency 70% 75.2%

Output Rate (kJ/h) 16,800 15,937 (Btu/h) Output Rate (kJ/h) 9,444 8,959 (Btu/h)

Burn Rate (kg/h) 1.11 2.45 (lb/h) Burn Rate (kg/h) 0.67 1.47 (lb/h)

Input (kJ/h) 22,450 21,296 (Btu/h) Input (kJ/h) 13,499 12,806 (Btu/h)

Test Load Weight (dry kg) 2.22 4.90 dry lb Test Load Weight (dry kg) 2.01 4.42 dry lb

MC wet (%) 3.85 MC wet (%) 3.85

MC dry (%) 4.00 MC dry (%) 4.00

Particulate (g ) - Particulate (g ) -

CO (g) 15 CO (g) 26

Test Duration (h) 2.00 Test Duration (h) 3.00

Emissions Particulate CO Emissions Particulate CO

g/MJ Output - 0.44 g/MJ Output - 0.93

g/kg Dry Fuel - 6.72 g/kg Dry Fuel - 13.19

g/h - 7.47 g/h - 8.82

lb/MM Btu Output - 1.03 lb/MM Btu Output - 2.17

Air/Fuel Ratio (A/F) 31.77 Air/Fuel Ratio (A/F) 57.12

VERSION: 2.2 12/14/2009 Modified to fit this Format

Test Results in Accordance with CSA B415.1-09 - Medium Test Results in Accordance with CSA B415.1-09 - Minimum

Test Results in Accordance with CSA B415.1-09 - MaximumTest Results in Accordance with CSA B415.1-09 - Overall

08/29/18

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Integrated Report

Page 14 of 68

Page 15: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc

Pellet Heater Conditioning Data - ASTM E2779

Manufacturer: Travis

Model: AGP PS

Tracking No.: 2308

Project No.: 0028PS108E

Test Date: 8/1/18 - 8/3/18

Operation Category: Medium

Elapsed Time

(hours)Fuel Added (lbs) Stack (°F)

0 +9 284

1 291

2 293

3 288

4 286

5 289

6 287

7 +20 275

8 289

9 295

10 291

11 288

12 287

13 282

14 286

15 290

16 292

17 291

18 +33 281

19 290

20 293

21 294

22 290

23 288

24 291

25 286

26 288

27 285

28 280

29 +22 281

30 291

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Conditioning

Page 15 of 68

Page 16: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc

Pellet Heater Conditioning Data - ASTM E2779

Manufacturer: Travis

Model: AGP PS

Tracking No.: 2308

Project No.: 0028PS108E

Test Date: 8/1/18 - 8/3/18

Operation Category: Medium

Elapsed Time

(hours)Fuel Added (lbs) Stack (°F)

31 293

32 286

33 289

34 293

35 288

36 290

37 289

38 291

39 286

40 +20 245

41 289

42 286

43 291

44 293

45 290

46 288

47 290

48 292

49 289

50 285

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Conditioning

Page 16 of 68

Page 17: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc

Pellet Heater Preburn Data - ASTM E2779

Manufacturer: Travis

Model: AGP PS

Tracking No.: 2308 PB Length: 60 min

Project No.: 0028PS108E Recording Interval: 1 min

Test Date: 8/29/2018

318 71 -0.04 8.16 0.23

Elapsed Time (min) Scale ReadingWeight

ChangeStack (F) Ambient (F) Draft ("H2O) CO2 (%) CO (%)

0 4.8 - 311 68 -0.04 - -

1 4.7 -0.08 312 68 -0.04 - -

2 4.6 -0.08 312 68 -0.04 - -

3 4.6 -0.08 313 68 -0.04 - -

4 4.5 -0.08 314 68 -0.04 - -

5 4.4 -0.08 314 69 -0.04 - -

6 4.3 -0.08 315 69 -0.04 - -

7 4.2 -0.08 315 69 -0.04 - -

8 4.1 -0.14 315 69 -0.04 - -

9 4.1 -0.02 315 69 -0.04 - -

10 4.0 -0.08 316 69 -0.04 - -

11 3.9 -0.08 316 69 -0.04 - -

12 3.8 -0.08 316 69 -0.04 - -

13 3.8 -0.08 316 70 -0.04 - -

14 3.7 -0.08 317 70 -0.04 - -

15 3.6 -0.08 316 70 -0.04 - -

16 3.5 -0.08 316 70 -0.04 - -

17 3.4 -0.08 316 70 -0.04 - -

18 3.4 -0.08 317 70 -0.04 - -

19 3.3 -0.08 317 70 -0.04 - -

20 3.2 -0.08 317 70 -0.04 - -

21 3.1 -0.08 317 70 -0.04 - -

22 3.0 -0.08 317 70 -0.04 - -

23 3.0 -0.08 318 70 -0.04 - -

24 2.9 -0.08 318 71 -0.04 - -

25 2.8 -0.08 317 72 -0.04 - -

26 2.7 -0.08 317 71 -0.04 - -

27 2.6 -0.08 318 70 -0.04 - -

28 2.6 -0.08 318 71 -0.04 - -

29 2.5 -0.08 318 71 -0.04 - -

Averages:

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Pre burn

Page 17 of 68

Page 18: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc

Pellet Heater Preburn Data - ASTM E2779

Manufacturer: Travis

Model: AGP PS

Tracking No.: 2308 PB Length: 60 min

Project No.: 0028PS108E Recording Interval: 1 min

Test Date: 8/29/2018

318 71 -0.04 8.16 0.23Averages:

30 2.4 -0.08 318 70 -0.04 - -

31 2.3 -0.08 318 70 -0.04 - -

32 2.2 -0.08 318 71 -0.04 - -

33 2.2 -0.08 317 71 -0.04 - -

34 2.1 -0.08 317 71 -0.04 - -

35 2.0 -0.08 317 71 -0.04 - -

36 1.9 -0.08 318 71 -0.04 8.48 0.34

37 1.8 -0.08 319 71 -0.04 8.63 0.41

38 1.8 -0.08 319 71 -0.04 8.05 0.20

39 1.7 -0.08 320 71 -0.04 8.06 0.16

40 1.6 -0.08 320 71 -0.04 7.67 0.27

41 1.5 -0.08 320 71 -0.04 8.56 0.35

42 1.4 -0.08 320 71 -0.04 7.87 0.10

43 1.4 -0.08 320 71 -0.04 8.28 0.13

44 1.3 -0.08 321 71 -0.04 8.53 0.18

45 1.2 -0.08 321 71 -0.04 8.43 0.26

46 1.1 -0.08 322 71 -0.04 8.95 0.43

47 1.0 -0.08 323 71 -0.04 8.45 0.37

48 1.0 -0.08 323 72 -0.04 8.36 0.25

49 0.9 -0.08 323 72 -0.04 8.17 0.12

50 0.8 -0.08 323 72 -0.04 8.17 0.12

51 0.7 -0.08 323 72 -0.04 7.84 0.20

52 0.6 -0.08 323 73 -0.04 8.15 0.13

53 0.6 -0.08 323 73 -0.04 8.21 0.40

54 0.5 -0.08 323 73 -0.04 7.28 0.09

55 0.4 -0.08 322 73 -0.04 8.10 0.32

56 0.3 -0.08 322 74 -0.04 7.94 0.12

57 0.2 -0.08 322 74 -0.04 7.58 0.06

58 0.2 -0.08 322 75 -0.04 - -

59 0.1 -0.08 321 75 -0.03 - -

60 0.0 -0.08 321 76 -0.04 7.84 0.20

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Pre burn

Page 18 of 68

Page 19: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc

Pellet Heater Test Data - ASTM E2779 / ASTM E2515PM Control Modules: 371/372

Run: 1 Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 14.22 ft/sec.

Travis High Burn End Time: 60 Dilution Tunnel MW(wet): 28.78 lb/lb-mole Intial Tunnel Flow: 156.8 scfm

AGP PS Medium Burn End Time: 180 Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 156.8 scfm

2308 360 min Dilution Tunnel Static: -0.150 "H2O Post-Test Leak Check (1): 0.000 cfm @ -6 in. Hg

0028PS108E Recording Interval: 1 min Tunnel Area: 0.1963 ft2

Post-Test Leak Check (2): 0.000 cfm @ -9 in. Hg

29-Aug-18 Pitot Tube Cp: 0.99 Fuel Moisture (%): 4.004 Dry Basis 3.850 Wet Basis

09:11 Background Sample Volume: 0 cubic feet 4.004 3.707

Meter Box Y Factor: 0.997 (1) 0.981 (2) 0 (Amb) Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

Initial dP 0.042 0.046 0.046 0.042 0.044 0.046 0.042 0.044 0.050 "H2O

Barometric Pressure: Begin Middle End Average Temp: 83 83 83 83 83 83 83 83 83 °F

29.36 29.37 29.37 29.37 "Hg Vstrav 14.23 ft/sec Vscent 15.17 ft/sec Fp 0.938

Particulate Sampling Data

Elapsed

Time

(min)

Gas Meter

1 (ft3)

Gas Meter

2 (ft3)

Sample

Rate 1

(cfm)

Sample

Rate 2

(cfm)

Orifice

dH 1

("H2O)

Meter

Temp 1

(°F)

Meter

Vacuum 1

("Hg)

Orifice

dH 2

("H2O)

Meter

Temp 2

(°F)

Meter

Vacuum 2

("Hg)

Dilution

Tunnel (°F)

Tunnel

Center

dP

Pro. Rate

1

Pro. Rate

2

Scale

Reading

Weight

ChangeStack Filter 1 Dryer 1 Filter 2 Dryer 2 Ambient

Draft

("H2O)CO2 (%) CO (%)

0 0.000 0.000 1.82 78 -0.79 1.35 77 -1.50 86 0.050 14.9 320 81 75 82 74 76 -0.046 7.68 0.120

1 0.136 0.138 0.14 0.14 1.73 78 -0.64 1.24 78 -1.10 86 0.050 93 95 14.8 -0.1 320 82 73 83 72 76 -0.047 8.10 0.100

2 0.278 0.282 0.14 0.14 1.71 78 -0.76 1.22 78 -1.50 86 0.050 97 99 14.7 -0.1 321 83 73 83 72 75 -0.047 8.21 0.090

3 0.429 0.428 0.15 0.15 1.90 78 -0.98 1.25 78 -1.40 86 0.050 103 100 14.6 -0.1 320 83 73 84 72 75 -0.046 8.26 0.240

4 0.578 0.572 0.15 0.14 1.87 79 -0.91 1.22 78 -1.30 86 0.050 102 99 14.5 -0.1 320 84 73 84 72 75 -0.046 7.91 0.130

5 0.727 0.716 0.15 0.14 1.84 79 -0.54 1.23 78 -1.60 86 0.050 102 99 14.5 -0.1 321 83 73 82 72 75 -0.047 8.14 0.150

6 0.875 0.860 0.15 0.14 1.81 79 -0.80 1.21 78 -1.30 86 0.050 101 99 14.4 -0.1 321 82 73 80 72 75 -0.047 8.45 0.150

7 1.021 1.003 0.15 0.14 1.79 79 -0.47 1.20 78 -1.50 86 0.050 100 98 14.3 -0.1 322 81 73 79 72 75 -0.046 8.76 0.300

8 1.167 1.147 0.15 0.14 1.81 79 -0.56 1.35 78 -1.60 86 0.050 100 99 14.2 -0.1 322 80 73 78 72 75 -0.047 8.38 0.200

9 1.314 1.298 0.15 0.15 1.80 79 -1.03 1.35 79 -1.80 85 0.050 100 103 14.1 -0.1 323 80 73 78 72 75 -0.047 8.43 0.200

10 1.461 1.450 0.15 0.15 1.79 79 -1.03 1.33 79 -1.80 84 0.050 100 104 14.0 -0.1 323 79 72 77 72 75 -0.048 8.50 0.170

11 1.607 1.600 0.15 0.15 1.77 79 -0.91 1.31 79 -2.00 84 0.050 100 102 13.9 -0.1 323 79 72 77 72 75 -0.048 8.49 0.110

12 1.751 1.750 0.14 0.15 1.76 79 -0.51 1.30 79 -2.20 84 0.050 98 102 13.8 -0.1 323 79 72 77 71 75 -0.048 8.06 0.130

13 1.896 1.898 0.15 0.15 1.75 79 -0.76 1.30 79 -2.10 83 0.050 99 101 13.8 -0.1 322 79 72 77 71 74 -0.047 7.89 0.150

14 2.039 2.047 0.14 0.15 1.73 79 -1.04 1.28 79 -2.40 83 0.050 97 102 13.7 -0.1 322 79 72 77 71 74 -0.047 7.65 0.190

15 2.187 2.195 0.15 0.15 1.84 79 -1.12 1.28 79 -2.20 83 0.050 101 101 13.6 -0.1 322 79 72 77 71 75 -0.046 8.18 0.160

16 2.335 2.342 0.15 0.15 1.82 79 -0.92 1.26 79 -2.50 82 0.050 101 100 13.5 -0.1 322 79 72 77 70 74 -0.048 7.86 0.290

17 2.482 2.489 0.15 0.15 1.80 79 -1.20 1.26 79 -2.50 82 0.050 100 100 13.4 -0.1 322 79 71 77 70 75 -0.047 8.00 0.280

18 2.628 2.635 0.15 0.15 1.79 79 -0.76 1.25 78 -2.60 82 0.050 99 100 13.4 -0.1 322 79 71 76 70 75 -0.049 8.24 0.100

19 2.773 2.779 0.15 0.14 1.77 79 -0.88 1.25 78 -2.40 81 0.050 99 98 13.3 -0.1 322 79 71 77 70 76 -0.048 7.73 0.170

20 2.921 2.925 0.15 0.15 1.90 79 -1.36 1.29 79 -2.40 81 0.050 101 99 13.2 -0.1 321 79 72 77 70 77 -0.049 7.77 0.230

21 3.071 3.073 0.15 0.15 1.88 79 -1.37 1.28 78 -2.40 81 0.050 102 101 13.1 -0.1 321 79 72 77 70 76 -0.048 7.82 0.120

22 3.221 3.221 0.15 0.15 1.86 79 -1.37 1.26 78 -2.30 81 0.050 102 101 13.0 -0.1 321 79 72 77 70 77 -0.046 7.79 0.180

23 3.369 3.367 0.15 0.15 1.85 79 -1.01 1.26 78 -1.80 81 0.050 101 100 12.9 -0.1 320 78 72 77 70 77 -0.048 7.94 0.260

24 3.518 3.513 0.15 0.15 1.82 79 -0.87 1.25 79 -1.80 81 0.050 101 99 12.8 -0.1 320 79 72 77 70 77 -0.048 7.91 0.150

25 3.666 3.658 0.15 0.15 1.80 79 -0.90 1.24 79 -2.00 81 0.050 101 99 12.8 -0.1 320 79 72 77 70 78 -0.047 8.57 0.410

26 3.813 3.805 0.15 0.15 1.79 79 -1.24 1.26 79 -2.00 81 0.050 100 100 12.7 -0.1 320 79 72 77 70 76 -0.048 8.19 0.150

27 3.959 3.951 0.15 0.15 1.78 79 -1.17 1.27 78 -1.90 81 0.050 99 100 12.6 -0.1 320 79 72 77 70 76 -0.047 8.61 0.290

28 4.104 4.098 0.15 0.15 1.77 79 -1.40 1.26 78 -2.10 81 0.050 99 100 12.5 -0.1 320 79 71 77 70 76 -0.047 8.35 0.260

29 4.249 4.244 0.15 0.15 1.75 79 -1.17 1.25 78 -2.50 81 0.050 99 100 12.4 -0.1 320 79 71 77 70 77 -0.047 8.51 0.210

30 4.398 4.391 0.15 0.15 1.92 79 -1.37 1.36 78 -3.10 81 0.050 101 100 12.3 -0.1 321 79 71 77 70 77 -0.047 8.19 0.130

31 4.550 4.542 0.15 0.15 1.91 79 -1.49 1.34 78 -3.30 81 0.050 103 103 12.2 -0.1 321 79 71 77 70 77 -0.047 7.98 0.320

32 4.701 4.693 0.15 0.15 1.90 78 -1.56 1.34 78 -3.40 81 0.050 103 103 12.1 -0.1 321 79 71 78 70 76 -0.048 8.27 0.190

33 4.851 4.845 0.15 0.15 1.89 78 -1.51 1.33 78 -3.00 80 0.050 102 104 12.1 -0.1 321 79 71 78 70 77 -0.047 7.73 0.050

34 5.000 4.995 0.15 0.15 1.88 78 -1.26 1.32 78 -2.90 80 0.050 101 102 12.0 -0.1 320 79 71 78 70 76 -0.047 8.40 0.270

35 5.149 5.145 0.15 0.15 1.87 78 -1.49 1.30 78 -2.80 80 0.050 101 102 11.9 -0.1 321 79 71 78 69 76 -0.048 7.72 0.100

36 5.298 5.294 0.15 0.15 1.85 78 -1.64 1.31 78 -2.90 80 0.050 101 102 11.8 -0.1 321 79 71 78 70 77 -0.049 8.55 0.230

37 5.446 5.443 0.15 0.15 1.83 78 -1.25 1.29 78 -3.10 81 0.050 101 102 11.7 -0.1 322 79 71 78 70 78 -0.046 8.82 0.220

38 5.594 5.590 0.15 0.15 1.82 78 -1.27 1.29 78 -3.10 81 0.050 101 100 11.7 -0.1 322 79 71 78 70 77 -0.048 8.49 0.160

39 5.741 5.738 0.15 0.15 1.81 78 -1.42 1.28 78 -2.90 81 0.050 100 101 11.6 -0.1 323 79 71 78 70 77 -0.048 8.19 0.070

40 5.888 5.886 0.15 0.15 1.79 78 -1.31 1.27 78 -2.80 80 0.050 100 101 11.5 -0.1 323 79 71 78 70 76 -0.047 8.77 0.530

41 6.034 6.032 0.15 0.15 1.78 78 -1.31 1.27 78 -3.00 80 0.050 99 99 11.4 -0.1 322 79 71 78 70 75 -0.048 8.03 0.210

42 6.179 6.178 0.15 0.15 1.79 78 -1.63 1.26 78 -2.90 80 0.050 99 99 11.3 -0.1 323 79 71 78 70 76 -0.048 8.08 0.180

43 6.325 6.324 0.15 0.15 1.76 78 -1.65 1.25 78 -2.90 80 0.050 99 99 11.2 -0.1 323 80 71 78 70 77 -0.048 8.86 0.470

44 6.469 6.469 0.14 0.15 1.75 78 -1.70 1.24 78 -2.90 81 0.050 98 99 11.1 -0.1 324 80 71 78 70 77 -0.048 9.08 0.560

45 6.613 6.614 0.14 0.15 1.73 78 -1.50 1.22 78 -2.90 81 0.050 98 99 11.1 -0.1 324 80 71 79 69 77 -0.048 7.89 0.220

46 6.756 6.758 0.14 0.14 1.73 78 -1.49 1.22 78 -3.20 81 0.050 97 98 11.0 -0.1 324 80 71 79 69 77 -0.048 8.14 0.520

47 6.899 6.902 0.14 0.14 1.70 78 -1.83 1.22 78 -3.30 81 0.050 97 98 10.9 -0.1 324 80 71 79 70 77 -0.048 8.10 0.140

48 7.047 7.048 0.15 0.15 1.87 78 -1.98 1.28 78 -3.10 81 0.050 101 100 10.8 -0.1 324 80 71 79 69 77 -0.048 8.17 0.270

Temperature Data (°F) Stack Gas Data

Velocity Traverse Data

Fuel Weight (lb)

Manufacturer:

Model:

Tracking No.:

Beginning Clock Time:

Total Sampling Time:

Project No.:

Test Date:

Export all Sheets to

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Data EntryPage 19 of 68

Page 20: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc

Pellet Heater Test Data - ASTM E2779 / ASTM E2515PM Control Modules: 371/372

Run: 1 Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 14.22 ft/sec.

Travis High Burn End Time: 60 Dilution Tunnel MW(wet): 28.78 lb/lb-mole Intial Tunnel Flow: 156.8 scfm

AGP PS Medium Burn End Time: 180 Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 156.8 scfm

2308 360 min Dilution Tunnel Static: -0.150 "H2O Post-Test Leak Check (1): 0.000 cfm @ -6 in. Hg

0028PS108E Recording Interval: 1 min Tunnel Area: 0.1963 ft2

Post-Test Leak Check (2): 0.000 cfm @ -9 in. Hg

29-Aug-18 Pitot Tube Cp: 0.99 Fuel Moisture (%): 4.004 Dry Basis 3.850 Wet Basis

09:11 Background Sample Volume: 0 cubic feet 4.004 3.707

Meter Box Y Factor: 0.997 (1) 0.981 (2) 0 (Amb) Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

Initial dP 0.042 0.046 0.046 0.042 0.044 0.046 0.042 0.044 0.050 "H2O

Barometric Pressure: Begin Middle End Average Temp: 83 83 83 83 83 83 83 83 83 °F

29.36 29.37 29.37 29.37 "Hg Vstrav 14.23 ft/sec Vscent 15.17 ft/sec Fp 0.938

Particulate Sampling Data

Elapsed

Time

(min)

Gas Meter

1 (ft3)

Gas Meter

2 (ft3)

Sample

Rate 1

(cfm)

Sample

Rate 2

(cfm)

Orifice

dH 1

("H2O)

Meter

Temp 1

(°F)

Meter

Vacuum 1

("Hg)

Orifice

dH 2

("H2O)

Meter

Temp 2

(°F)

Meter

Vacuum 2

("Hg)

Dilution

Tunnel (°F)

Tunnel

Center

dP

Pro. Rate

1

Pro. Rate

2

Scale

Reading

Weight

ChangeStack Filter 1 Dryer 1 Filter 2 Dryer 2 Ambient

Draft

("H2O)CO2 (%) CO (%)

Temperature Data (°F) Stack Gas Data

Velocity Traverse Data

Fuel Weight (lb)

Manufacturer:

Model:

Tracking No.:

Beginning Clock Time:

Total Sampling Time:

Project No.:

Test Date:

Export all Sheets to

49 7.196 7.195 0.15 0.15 1.86 78 -1.68 1.26 78 -3.20 81 0.050 102 100 10.7 -0.1 324 80 71 79 69 76 -0.048 7.60 0.240

50 7.345 7.342 0.15 0.15 1.85 78 -2.07 1.25 78 -3.30 81 0.050 102 100 10.6 -0.1 323 80 71 79 69 77 -0.048 7.91 0.190

51 7.492 7.487 0.15 0.15 1.82 78 -2.07 1.25 78 -3.10 81 0.050 100 99 10.5 -0.1 323 80 71 79 69 77 -0.046 7.55 0.070

52 7.640 7.633 0.15 0.15 1.83 78 -1.69 1.25 78 -3.20 81 0.050 101 100 10.4 -0.1 323 80 71 79 69 76 -0.049 8.12 0.170

53 7.787 7.778 0.15 0.15 1.79 78 -1.70 1.26 78 -3.30 81 0.050 100 99 10.3 -0.1 323 80 71 79 69 76 -0.049 8.12 0.370

54 7.933 7.925 0.15 0.15 1.77 78 -1.70 1.25 78 -3.40 81 0.050 99 100 10.2 -0.1 323 80 71 79 69 77 -0.048 8.52 0.490

55 8.079 8.070 0.15 0.15 1.77 78 -2.10 1.24 78 -3.40 81 0.050 99 99 10.2 -0.1 323 80 71 79 69 77 -0.047 8.03 0.230

56 8.225 8.216 0.15 0.15 1.83 78 -1.87 1.26 78 -3.10 81 0.050 99 100 10.1 -0.1 322 80 71 79 69 77 -0.047 7.86 0.150

57 8.372 8.362 0.15 0.15 1.82 78 -1.84 1.26 78 -3.40 81 0.050 100 100 10.0 -0.1 322 80 71 79 69 77 -0.048 8.07 0.160

58 8.518 8.508 0.15 0.15 1.80 78 -2.03 1.24 78 -3.30 81 0.050 99 100 9.9 -0.1 322 80 71 79 69 77 -0.048 8.24 0.490

59 8.664 8.653 0.15 0.15 1.79 77 -2.27 1.23 78 -3.50 81 0.050 100 99 9.8 -0.1 323 80 71 79 69 77 -0.047 8.84 0.440

60 8.809 8.798 0.15 0.15 1.75 77 -2.22 1.22 78 -3.50 81 0.050 99 99 9.7 -0.1 324 80 71 79 69 76 -0.047 8.84 0.640

61 8.960 8.941 0.15 0.14 2.77 77 -0.86 1.22 78 -3.50 81 0.050 103 98 9.6 -0.1 325 80 71 79 69 77 -0.048 8.68 0.400

62 9.111 9.086 0.15 0.15 1.88 77 -0.52 1.25 78 -3.60 81 0.050 103 99 9.6 -0.1 324 80 71 79 69 77 -0.048 8.19 0.150

63 9.260 9.231 0.15 0.15 1.86 77 -0.53 1.24 78 -3.40 81 0.050 102 99 9.5 -0.1 325 80 71 80 69 77 -0.049 8.42 0.320

64 9.408 9.376 0.15 0.15 1.85 77 -0.47 1.23 78 -3.50 81 0.050 101 99 9.4 -0.1 325 80 71 80 69 77 -0.048 8.63 0.110

65 9.556 9.520 0.15 0.14 1.83 77 -0.54 1.24 78 -3.50 81 0.050 101 98 9.4 -0.1 325 80 71 80 69 77 -0.048 7.83 0.060

66 9.704 9.668 0.15 0.15 1.82 77 -0.63 1.29 78 -3.60 81 0.050 101 101 9.3 -0.1 324 80 71 80 69 77 -0.048 7.22 0.060

67 9.850 9.816 0.15 0.15 1.81 77 -0.92 1.28 78 -3.60 81 0.050 100 101 9.2 -0.1 323 80 71 80 69 77 -0.047 6.83 0.060

68 9.997 9.963 0.15 0.15 1.81 77 -0.51 1.28 78 -3.70 81 0.050 100 100 9.1 -0.1 321 80 71 80 69 76 -0.046 6.24 0.030

69 10.144 10.110 0.15 0.15 1.80 77 -0.53 1.27 78 -3.80 81 0.050 100 100 9.1 -0.1 320 80 71 80 69 77 -0.046 6.22 0.020

70 10.291 10.258 0.15 0.15 1.82 77 -0.52 1.27 78 -3.30 81 0.050 100 101 9.0 -0.1 317 80 71 80 69 77 -0.046 5.23 0.020

71 10.438 10.405 0.15 0.15 1.82 77 -0.59 1.29 78 -3.60 81 0.050 100 100 9.0 -0.1 315 79 71 80 69 77 -0.046 4.85 0.020

72 10.584 10.553 0.15 0.15 1.82 77 -0.78 1.28 78 -3.40 81 0.050 100 101 8.9 -0.1 311 79 71 80 69 76 -0.045 4.04 0.020

73 10.731 10.700 0.15 0.15 1.81 77 -0.66 1.28 78 -3.50 81 0.050 100 100 8.9 -0.1 308 79 71 80 69 76 -0.044 4.22 0.020

74 10.878 10.848 0.15 0.15 1.81 77 -0.54 1.28 78 -3.60 81 0.050 100 101 8.8 -0.1 305 80 71 80 69 76 -0.046 4.27 0.010

75 11.025 10.995 0.15 0.15 1.81 77 -0.72 1.27 78 -3.40 80 0.050 100 100 8.8 -0.1 301 80 71 80 69 76 -0.043 4.22 0.010

76 11.172 11.143 0.15 0.15 1.81 77 -0.46 1.27 78 -3.30 80 0.050 100 101 8.7 -0.1 298 79 71 80 69 76 -0.043 4.30 0.010

77 11.318 11.289 0.15 0.15 1.81 77 -0.53 1.28 78 -3.60 80 0.050 100 99 8.7 -0.1 295 79 71 80 69 76 -0.043 4.31 0.020

78 11.465 11.437 0.15 0.15 1.80 77 -0.73 1.27 78 -3.40 80 0.050 100 101 8.6 -0.1 293 79 71 80 69 77 -0.042 3.96 0.020

79 11.611 11.584 0.15 0.15 1.80 77 -0.62 1.27 78 -3.30 80 0.050 100 100 8.6 -0.1 290 79 71 80 69 77 -0.042 4.29 0.010

80 11.758 11.731 0.15 0.15 1.81 77 -0.45 1.27 78 -3.40 80 0.050 100 100 8.5 -0.1 288 79 71 80 69 77 -0.040 3.96 0.010

81 11.904 11.878 0.15 0.15 1.81 77 -0.58 1.27 78 -3.80 80 0.050 100 100 8.5 0.0 286 79 71 80 69 76 -0.040 3.92 0.010

82 12.051 12.025 0.15 0.15 1.81 77 -0.50 1.27 78 -3.70 80 0.050 100 100 8.4 0.0 285 79 70 80 69 75 -0.042 3.71 0.010

83 12.198 12.173 0.15 0.15 1.80 77 -0.91 1.27 78 -3.70 80 0.050 100 101 8.4 0.0 281 79 70 80 68 75 -0.041 3.26 0.010

84 12.344 12.319 0.15 0.15 1.81 77 -0.49 1.27 77 -3.70 80 0.050 100 100 8.4 0.0 280 79 70 80 68 76 -0.040 3.75 0.010

85 12.490 12.467 0.15 0.15 1.80 77 -0.58 1.27 77 -3.50 80 0.050 100 101 8.4 0.0 277 79 70 80 68 75 -0.039 4.08 0.010

86 12.637 12.614 0.15 0.15 1.80 77 -0.89 1.27 77 -3.40 80 0.050 100 100 8.3 0.0 277 79 70 80 68 75 -0.041 4.06 0.010

87 12.783 12.761 0.15 0.15 1.81 77 -0.93 1.28 77 -2.90 80 0.050 100 100 8.3 0.0 274 79 70 80 68 76 -0.040 3.49 0.000

88 12.930 12.909 0.15 0.15 1.81 77 -0.92 1.27 77 -2.80 80 0.050 100 101 8.3 0.0 273 79 70 80 68 76 -0.038 3.52 0.000

89 13.076 13.056 0.15 0.15 1.81 77 -0.92 1.26 77 -3.00 80 0.050 100 100 8.2 0.0 271 79 70 80 68 75 -0.038 3.85 0.010

90 13.222 13.203 0.15 0.15 1.81 77 -0.69 1.28 77 -3.10 80 0.050 100 100 8.2 0.0 269 79 70 80 68 75 -0.037 4.03 0.000

91 13.369 13.350 0.15 0.15 1.81 76 -0.73 1.28 77 -3.20 79 0.050 100 100 8.2 0.0 268 79 70 80 68 74 -0.037 3.52 0.000

92 13.515 13.498 0.15 0.15 1.81 76 -0.77 1.27 77 -3.30 79 0.050 100 101 8.1 0.0 267 79 70 80 68 75 -0.037 4.36 0.000

93 13.662 13.645 0.15 0.15 1.81 76 -0.79 1.28 77 -3.30 79 0.050 100 100 8.1 0.0 265 79 70 80 68 74 -0.036 3.08 0.000

94 13.808 13.792 0.15 0.15 1.80 76 -0.56 1.26 77 -2.90 79 0.050 100 100 8.0 0.0 263 79 70 80 68 75 -0.037 3.07 0.000

95 13.954 13.939 0.15 0.15 1.81 76 -0.56 1.26 76 -3.10 79 0.050 100 100 8.0 0.0 262 79 70 80 67 75 -0.036 3.37 0.000

96 14.100 14.086 0.15 0.15 1.81 76 -0.84 1.28 76 -2.90 79 0.050 100 100 8.0 0.0 260 79 70 80 67 75 -0.035 3.66 0.000

97 14.247 14.233 0.15 0.15 1.81 76 -0.55 1.27 77 -2.80 79 0.050 100 100 7.9 0.0 259 79 70 80 67 75 -0.035 3.21 0.010

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Data EntryPage 20 of 68

Page 21: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc

Pellet Heater Test Data - ASTM E2779 / ASTM E2515PM Control Modules: 371/372

Run: 1 Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 14.22 ft/sec.

Travis High Burn End Time: 60 Dilution Tunnel MW(wet): 28.78 lb/lb-mole Intial Tunnel Flow: 156.8 scfm

AGP PS Medium Burn End Time: 180 Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 156.8 scfm

2308 360 min Dilution Tunnel Static: -0.150 "H2O Post-Test Leak Check (1): 0.000 cfm @ -6 in. Hg

0028PS108E Recording Interval: 1 min Tunnel Area: 0.1963 ft2

Post-Test Leak Check (2): 0.000 cfm @ -9 in. Hg

29-Aug-18 Pitot Tube Cp: 0.99 Fuel Moisture (%): 4.004 Dry Basis 3.850 Wet Basis

09:11 Background Sample Volume: 0 cubic feet 4.004 3.707

Meter Box Y Factor: 0.997 (1) 0.981 (2) 0 (Amb) Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

Initial dP 0.042 0.046 0.046 0.042 0.044 0.046 0.042 0.044 0.050 "H2O

Barometric Pressure: Begin Middle End Average Temp: 83 83 83 83 83 83 83 83 83 °F

29.36 29.37 29.37 29.37 "Hg Vstrav 14.23 ft/sec Vscent 15.17 ft/sec Fp 0.938

Particulate Sampling Data

Elapsed

Time

(min)

Gas Meter

1 (ft3)

Gas Meter

2 (ft3)

Sample

Rate 1

(cfm)

Sample

Rate 2

(cfm)

Orifice

dH 1

("H2O)

Meter

Temp 1

(°F)

Meter

Vacuum 1

("Hg)

Orifice

dH 2

("H2O)

Meter

Temp 2

(°F)

Meter

Vacuum 2

("Hg)

Dilution

Tunnel (°F)

Tunnel

Center

dP

Pro. Rate

1

Pro. Rate

2

Scale

Reading

Weight

ChangeStack Filter 1 Dryer 1 Filter 2 Dryer 2 Ambient

Draft

("H2O)CO2 (%) CO (%)

Temperature Data (°F) Stack Gas Data

Velocity Traverse Data

Fuel Weight (lb)

Manufacturer:

Model:

Tracking No.:

Beginning Clock Time:

Total Sampling Time:

Project No.:

Test Date:

Export all Sheets to

98 14.393 14.380 0.15 0.15 1.80 76 -0.90 1.27 76 -2.90 79 0.050 100 100 7.9 0.0 258 79 70 80 68 76 -0.035 4.17 0.000

99 14.539 14.527 0.15 0.15 1.79 76 -0.50 1.27 76 -3.10 79 0.050 100 100 7.8 0.0 257 79 70 80 68 75 -0.034 2.95 0.000

100 14.685 14.674 0.15 0.15 1.79 76 -0.46 1.27 76 -2.80 79 0.050 100 100 7.8 0.0 255 79 70 80 68 74 -0.034 3.16 0.010

101 14.830 14.821 0.15 0.15 1.79 76 -0.52 1.27 76 -3.00 79 0.050 99 100 7.8 0.0 254 79 70 80 68 75 -0.035 3.49 0.010

102 14.976 14.968 0.15 0.15 1.79 76 -0.67 1.26 77 -3.20 79 0.050 100 100 7.7 0.0 254 79 70 80 68 75 -0.035 3.81 0.010

103 15.122 15.115 0.15 0.15 1.79 76 -0.63 1.28 77 -2.90 79 0.050 100 100 7.7 0.0 253 79 70 80 68 75 -0.035 2.90 0.010

104 15.268 15.261 0.15 0.15 1.79 76 -0.45 1.26 77 -3.20 79 0.050 100 100 7.6 0.0 251 79 70 80 68 75 -0.034 2.74 0.020

105 15.414 15.408 0.15 0.15 1.78 76 -0.47 1.27 77 -3.00 79 0.050 100 100 7.6 0.0 251 79 70 80 68 75 -0.034 3.49 0.010

106 15.559 15.555 0.15 0.15 1.77 76 -0.93 1.26 77 -3.00 80 0.050 99 100 7.6 0.0 249 79 70 79 68 75 -0.035 3.39 0.010

107 15.705 15.702 0.15 0.15 1.78 76 -0.66 1.27 77 -3.20 80 0.050 100 100 7.5 0.0 250 79 70 79 68 75 -0.034 3.45 0.010

108 15.850 15.849 0.15 0.15 1.77 76 -0.48 1.26 77 -3.30 80 0.050 99 100 7.5 0.0 249 79 70 79 68 75 -0.035 3.44 0.020

109 15.996 15.995 0.15 0.15 1.78 76 -0.80 1.26 77 -3.20 80 0.050 100 100 7.4 0.0 249 79 70 79 68 75 -0.034 3.07 0.010

110 16.142 16.142 0.15 0.15 1.78 76 -0.63 1.28 77 -3.30 80 0.050 100 100 7.4 0.0 247 79 70 79 68 76 -0.034 2.83 0.020

111 16.288 16.288 0.15 0.15 1.77 76 -0.52 1.27 77 -3.10 80 0.050 100 100 7.4 0.0 247 79 70 79 68 75 -0.032 3.17 0.020

112 16.433 16.435 0.15 0.15 1.79 76 -0.83 1.27 77 -3.30 80 0.050 99 100 7.3 0.0 247 79 70 79 68 75 -0.033 3.34 0.010

113 16.579 16.582 0.15 0.15 1.79 76 -0.93 1.26 77 -3.00 80 0.050 100 100 7.3 0.0 247 79 70 79 68 75 -0.032 3.71 0.010

114 16.725 16.729 0.15 0.15 1.79 76 -0.90 1.27 77 -3.30 79 0.050 100 100 7.2 0.0 247 79 70 79 68 74 -0.032 3.23 0.010

115 16.871 16.876 0.15 0.15 1.79 76 -0.71 1.26 77 -3.40 79 0.050 100 100 7.2 0.0 246 79 70 79 68 75 -0.031 3.47 0.010

116 17.017 17.023 0.15 0.15 1.80 76 -0.50 1.26 77 -3.30 79 0.050 100 100 7.2 0.0 246 79 70 79 68 75 -0.032 3.35 0.010

117 17.162 17.169 0.15 0.15 1.79 76 -0.59 1.26 77 -3.30 80 0.050 99 100 7.1 0.0 245 79 70 79 68 75 -0.032 3.73 0.010

118 17.308 17.316 0.15 0.15 1.79 76 -0.79 1.27 77 -3.30 79 0.050 100 100 7.1 0.0 244 79 70 79 68 75 -0.032 3.20 0.010

119 17.454 17.463 0.15 0.15 1.79 76 -0.93 1.26 77 -3.30 79 0.050 100 100 7.0 0.0 244 79 70 79 68 75 -0.032 3.10 0.010

120 17.600 17.609 0.15 0.15 1.80 76 -0.89 1.27 77 -3.40 79 0.050 100 100 7.0 0.0 244 79 70 79 68 75 -0.034 3.14 0.010

121 17.746 17.756 0.15 0.15 1.80 76 -0.67 1.27 77 -3.40 79 0.050 100 100 7.0 0.0 243 79 70 79 68 75 -0.033 2.99 0.010

122 17.891 17.903 0.15 0.15 1.79 76 -0.89 1.26 77 -4.20 79 0.050 99 100 6.9 0.0 243 79 70 79 68 75 -0.032 3.28 0.010

123 18.037 18.049 0.15 0.15 1.79 76 -0.49 1.26 77 -4.60 79 0.050 100 100 6.9 0.0 243 79 70 79 68 76 -0.032 3.53 0.010

124 18.182 18.196 0.15 0.15 1.78 76 -0.93 1.26 77 -3.90 80 0.050 99 100 6.8 0.0 243 79 70 79 68 75 -0.031 3.09 0.020

125 18.328 18.342 0.15 0.15 1.78 76 -0.51 1.27 77 -4.10 80 0.050 100 100 6.8 0.0 243 79 70 79 68 75 -0.031 3.42 0.010

126 18.473 18.488 0.15 0.15 1.77 76 -0.47 1.27 77 -4.40 80 0.050 99 100 6.8 0.0 243 79 70 79 68 75 -0.032 3.66 0.010

127 18.619 18.636 0.15 0.15 1.77 76 -0.87 1.27 77 -4.30 80 0.050 100 101 6.7 0.0 243 79 70 79 68 75 -0.032 2.81 0.020

128 18.764 18.782 0.15 0.15 1.77 76 -0.93 1.26 77 -4.30 80 0.050 99 100 6.7 0.0 243 78 70 79 68 75 -0.033 3.41 0.020

129 18.909 18.928 0.15 0.15 1.77 76 -0.93 1.26 77 -3.80 80 0.050 99 100 6.6 0.0 242 78 70 79 68 75 -0.032 3.46 0.020

130 19.054 19.075 0.15 0.15 1.77 76 -0.52 1.26 77 -3.80 80 0.050 99 100 6.6 0.0 243 78 70 79 68 75 -0.033 3.83 0.010

131 19.200 19.221 0.15 0.15 1.77 76 -0.94 1.26 77 -3.80 81 0.050 100 100 6.6 0.0 242 78 70 79 68 75 -0.031 2.89 0.020

132 19.345 19.368 0.15 0.15 1.78 76 -0.70 1.25 77 -4.10 81 0.050 99 100 6.5 0.0 242 78 70 79 69 75 -0.032 2.87 0.020

133 19.491 19.514 0.15 0.15 1.79 76 -0.49 1.27 77 -4.30 80 0.050 100 100 6.5 0.0 242 78 70 79 68 75 -0.032 3.43 0.010

134 19.636 19.660 0.15 0.15 1.79 76 -0.94 1.26 77 -4.00 80 0.050 99 100 6.4 0.0 242 78 70 79 68 75 -0.031 3.19 0.020

135 19.782 19.807 0.15 0.15 1.77 76 -0.66 1.26 77 -4.20 80 0.050 100 100 6.4 0.0 242 78 70 79 68 74 -0.031 3.61 0.010

136 19.927 19.954 0.15 0.15 1.78 76 -0.83 1.26 77 -3.90 80 0.050 99 100 6.4 0.0 243 78 70 79 68 74 -0.033 3.62 0.020

137 20.072 20.100 0.15 0.15 1.79 76 -0.84 1.27 77 -3.80 80 0.050 99 100 6.3 0.0 243 78 70 79 68 74 -0.032 3.31 0.010

138 20.218 20.246 0.15 0.15 1.79 76 -0.78 1.25 77 -3.90 80 0.050 100 100 6.3 0.0 242 78 70 79 68 75 -0.031 3.35 0.020

139 20.364 20.393 0.15 0.15 1.79 76 -0.48 1.26 77 -4.00 80 0.050 100 100 6.2 0.0 242 78 70 79 68 75 -0.032 3.47 0.020

140 20.509 20.539 0.15 0.15 1.79 76 -0.57 1.25 77 -3.90 80 0.050 99 100 6.2 0.0 242 78 70 79 68 75 -0.032 3.43 0.010

141 20.654 20.685 0.15 0.15 1.79 76 -0.46 1.27 77 -4.00 80 0.050 99 100 6.2 0.0 242 78 70 79 68 75 -0.032 3.53 0.010

142 20.800 20.832 0.15 0.15 1.78 76 -0.64 1.26 77 -3.30 80 0.050 100 100 6.1 0.0 242 78 70 79 68 75 -0.032 3.28 0.010

143 20.945 20.978 0.15 0.15 1.78 76 -0.50 1.27 77 -3.20 79 0.050 99 100 6.1 0.0 242 78 70 79 68 75 -0.032 3.55 0.010

144 21.090 21.125 0.15 0.15 1.77 76 -0.86 1.26 77 -3.00 79 0.050 99 100 6.0 0.0 241 78 70 79 68 75 -0.032 3.09 0.010

145 21.235 21.271 0.15 0.15 1.77 76 -0.89 1.26 77 -3.30 80 0.050 99 100 6.0 0.0 242 78 70 79 68 76 -0.033 3.42 0.010

146 21.381 21.417 0.15 0.15 1.77 76 -0.94 1.25 77 -3.00 80 0.050 100 100 6.0 0.0 242 78 70 79 68 76 -0.032 3.38 0.010

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Data EntryPage 21 of 68

Page 22: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc

Pellet Heater Test Data - ASTM E2779 / ASTM E2515PM Control Modules: 371/372

Run: 1 Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 14.22 ft/sec.

Travis High Burn End Time: 60 Dilution Tunnel MW(wet): 28.78 lb/lb-mole Intial Tunnel Flow: 156.8 scfm

AGP PS Medium Burn End Time: 180 Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 156.8 scfm

2308 360 min Dilution Tunnel Static: -0.150 "H2O Post-Test Leak Check (1): 0.000 cfm @ -6 in. Hg

0028PS108E Recording Interval: 1 min Tunnel Area: 0.1963 ft2

Post-Test Leak Check (2): 0.000 cfm @ -9 in. Hg

29-Aug-18 Pitot Tube Cp: 0.99 Fuel Moisture (%): 4.004 Dry Basis 3.850 Wet Basis

09:11 Background Sample Volume: 0 cubic feet 4.004 3.707

Meter Box Y Factor: 0.997 (1) 0.981 (2) 0 (Amb) Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

Initial dP 0.042 0.046 0.046 0.042 0.044 0.046 0.042 0.044 0.050 "H2O

Barometric Pressure: Begin Middle End Average Temp: 83 83 83 83 83 83 83 83 83 °F

29.36 29.37 29.37 29.37 "Hg Vstrav 14.23 ft/sec Vscent 15.17 ft/sec Fp 0.938

Particulate Sampling Data

Elapsed

Time

(min)

Gas Meter

1 (ft3)

Gas Meter

2 (ft3)

Sample

Rate 1

(cfm)

Sample

Rate 2

(cfm)

Orifice

dH 1

("H2O)

Meter

Temp 1

(°F)

Meter

Vacuum 1

("Hg)

Orifice

dH 2

("H2O)

Meter

Temp 2

(°F)

Meter

Vacuum 2

("Hg)

Dilution

Tunnel (°F)

Tunnel

Center

dP

Pro. Rate

1

Pro. Rate

2

Scale

Reading

Weight

ChangeStack Filter 1 Dryer 1 Filter 2 Dryer 2 Ambient

Draft

("H2O)CO2 (%) CO (%)

Temperature Data (°F) Stack Gas Data

Velocity Traverse Data

Fuel Weight (lb)

Manufacturer:

Model:

Tracking No.:

Beginning Clock Time:

Total Sampling Time:

Project No.:

Test Date:

Export all Sheets to

147 21.526 21.564 0.15 0.15 1.77 76 -0.58 1.25 76 -3.00 80 0.050 99 101 5.9 0.0 243 78 70 79 68 75 -0.032 3.53 0.010

148 21.671 21.711 0.15 0.15 1.76 76 -0.47 1.25 76 -3.40 80 0.050 99 101 5.9 0.0 242 78 70 79 68 75 -0.032 3.01 0.020

149 21.816 21.857 0.15 0.15 1.77 76 -0.52 1.26 76 -3.20 79 0.050 99 100 5.8 0.0 243 78 70 79 68 75 -0.033 2.98 0.020

150 21.961 22.002 0.15 0.15 1.77 76 -0.71 1.26 76 -3.80 79 0.050 99 99 5.8 0.0 243 78 70 79 68 75 -0.033 2.97 0.010

151 22.107 22.149 0.15 0.15 1.78 76 -0.83 1.26 76 -4.30 79 0.050 100 100 5.8 0.0 243 78 70 79 68 75 -0.033 3.54 0.010

152 22.251 22.296 0.14 0.15 1.78 76 -0.92 1.25 76 -4.20 79 0.050 98 100 5.7 0.0 243 78 70 79 68 75 -0.032 3.61 0.020

153 22.397 22.442 0.15 0.15 1.78 76 -0.78 1.26 76 -3.80 80 0.050 100 100 5.7 0.0 244 78 70 79 68 75 -0.033 3.59 0.020

154 22.542 22.588 0.15 0.15 1.76 76 -0.47 1.25 77 -4.10 80 0.050 99 100 5.6 0.0 243 78 70 79 69 76 -0.033 2.97 0.020

155 22.688 22.734 0.15 0.15 1.78 76 -0.93 1.25 77 -3.90 79 0.050 100 100 5.6 0.0 243 78 70 79 69 76 -0.032 3.26 0.010

156 22.833 22.881 0.15 0.15 1.78 76 -0.85 1.25 77 -3.60 79 0.050 99 100 5.6 0.0 243 78 70 79 69 75 -0.033 3.07 0.020

157 22.978 23.027 0.15 0.15 1.78 76 -0.55 1.26 76 -3.20 79 0.050 99 100 5.5 0.0 243 78 70 79 68 75 -0.031 3.80 0.010

158 23.123 23.173 0.15 0.15 1.76 76 -0.90 1.26 76 -3.30 79 0.050 99 100 5.5 0.0 242 78 70 79 68 75 -0.033 3.39 0.010

159 23.268 23.319 0.15 0.15 1.75 76 -0.89 1.26 76 -3.20 79 0.050 99 100 5.4 0.0 242 78 70 79 68 75 -0.033 3.21 0.020

160 23.412 23.465 0.14 0.15 1.76 76 -0.48 1.25 76 -3.70 80 0.050 98 100 5.4 0.0 242 78 70 79 68 75 -0.032 3.53 0.020

161 23.557 23.611 0.15 0.15 1.75 76 -0.67 1.25 76 -4.20 80 0.050 99 100 5.4 0.0 242 78 70 78 68 75 -0.031 2.85 0.020

162 23.702 23.757 0.15 0.15 1.75 76 -0.50 1.25 76 -3.90 80 0.050 99 100 5.3 0.0 243 78 70 78 68 76 -0.031 3.11 0.020

163 23.847 23.902 0.15 0.15 1.76 76 -0.93 1.25 76 -3.80 80 0.050 99 99 5.3 0.0 243 78 70 78 69 76 -0.032 3.89 0.010

164 23.991 24.048 0.14 0.15 1.77 76 -0.79 1.25 76 -4.00 80 0.050 98 100 5.2 0.0 243 78 70 79 69 75 -0.032 3.35 0.020

165 24.136 24.193 0.15 0.15 1.77 76 -0.52 1.25 76 -3.70 80 0.050 99 99 5.2 0.0 243 78 70 79 69 75 -0.033 3.00 0.020

166 24.281 24.339 0.15 0.15 1.77 76 -0.65 1.24 77 -4.00 80 0.050 99 100 5.2 0.0 244 78 70 78 69 75 -0.032 3.56 0.020

167 24.426 24.485 0.15 0.15 1.77 76 -0.49 1.24 77 -3.90 81 0.050 99 100 5.1 0.0 243 78 70 78 69 76 -0.032 3.63 0.020

168 24.571 24.630 0.15 0.15 1.77 76 -0.95 1.26 77 -3.70 81 0.050 99 99 5.1 0.0 244 78 70 78 69 76 -0.032 3.49 0.020

169 24.715 24.776 0.14 0.15 1.76 77 -0.86 1.25 77 -3.60 81 0.050 98 100 5.0 0.0 244 78 70 78 69 76 -0.032 3.20 0.020

170 24.860 24.921 0.15 0.15 1.76 77 -0.55 1.25 77 -3.30 81 0.050 99 99 5.0 0.0 244 78 70 78 69 76 -0.032 3.39 0.020

171 25.004 25.067 0.14 0.15 1.74 77 -0.47 1.25 77 -3.50 81 0.050 98 100 5.0 0.0 244 78 70 78 69 76 -0.033 2.97 0.020

172 25.148 25.213 0.14 0.15 1.75 77 -0.48 1.25 77 -3.40 81 0.050 98 100 4.9 0.0 244 78 71 78 69 76 -0.032 3.51 0.010

173 25.293 25.358 0.15 0.15 1.75 77 -0.59 1.24 77 -3.30 81 0.050 99 99 4.9 0.0 244 78 71 78 69 76 -0.033 3.41 0.020

174 25.438 25.504 0.15 0.15 1.76 77 -0.68 1.25 77 -3.30 81 0.050 99 100 4.8 0.0 244 78 71 78 69 76 -0.033 3.67 0.020

175 25.582 25.649 0.14 0.15 1.76 77 -0.80 1.24 77 -3.20 81 0.050 98 99 4.8 0.0 243 78 71 78 69 76 -0.032 3.00 0.020

176 25.727 25.795 0.15 0.15 1.77 77 -0.88 1.25 77 -3.40 81 0.050 99 100 4.8 0.0 244 78 71 78 70 76 -0.032 3.54 0.020

177 25.871 25.941 0.14 0.15 1.77 77 -0.48 1.25 77 -3.30 81 0.050 98 100 4.7 0.0 243 78 71 78 70 76 -0.032 3.14 0.020

178 26.017 26.086 0.15 0.15 1.77 78 -0.54 1.25 77 -3.30 81 0.050 99 99 4.7 0.0 244 78 71 78 70 76 -0.032 3.23 0.020

179 26.162 26.232 0.15 0.15 1.76 78 -0.57 1.25 78 -3.40 81 0.050 99 100 4.6 0.0 243 78 71 78 70 77 -0.033 3.33 0.020

180 26.306 26.377 0.14 0.15 1.77 78 -0.56 1.25 78 -3.20 81 0.050 98 99 4.6 0.0 244 78 71 78 70 76 -0.034 3.74 0.020

181 26.454 26.523 0.15 0.15 1.84 78 -0.82 1.24 78 -3.30 81 0.050 101 100 4.6 0.0 244 78 71 78 70 76 -0.032 3.26 0.020

182 26.602 26.668 0.15 0.15 1.85 78 -0.72 1.24 78 -3.10 81 0.050 101 99 4.5 0.0 243 78 71 78 70 76 -0.034 3.16 0.020

183 26.750 26.813 0.15 0.15 1.83 78 -0.60 1.24 78 -3.20 81 0.050 101 99 4.5 0.0 243 78 71 78 70 76 -0.033 3.72 0.010

184 26.897 26.958 0.15 0.15 1.85 78 -0.66 1.23 78 -3.10 81 0.050 100 99 4.5 0.0 244 78 71 78 70 76 -0.033 3.63 0.020

185 27.045 27.105 0.15 0.15 1.85 78 -0.98 1.27 78 -3.20 81 0.050 101 100 4.5 0.0 243 78 71 78 70 76 -0.032 3.14 0.010

186 27.193 27.252 0.15 0.15 1.85 78 -1.00 1.27 78 -3.10 81 0.050 101 100 4.4 0.0 241 78 71 78 70 76 -0.032 2.22 0.030

187 27.341 27.400 0.15 0.15 1.84 78 -0.82 1.26 78 -3.20 82 0.050 101 101 4.4 0.0 239 78 72 78 70 76 -0.031 1.80 0.050

188 27.489 27.546 0.15 0.15 1.83 78 -0.61 1.28 78 -3.30 82 0.050 101 100 4.4 0.0 239 78 72 78 70 76 -0.033 3.21 0.010

189 27.637 27.693 0.15 0.15 1.84 79 -0.55 1.27 78 -3.10 82 0.050 101 100 4.3 0.0 237 78 72 78 70 77 -0.030 2.84 0.020

190 27.785 27.840 0.15 0.15 1.84 79 -1.02 1.27 78 -3.10 83 0.050 101 100 4.3 0.0 236 78 72 78 70 77 -0.029 2.29 0.020

191 27.933 27.988 0.15 0.15 1.83 79 -0.79 1.27 78 -3.00 83 0.050 101 101 4.3 0.0 236 78 72 78 70 77 -0.030 2.81 0.020

192 28.080 28.134 0.15 0.15 1.83 79 -1.00 1.27 78 -3.30 83 0.050 100 100 4.2 0.0 234 78 72 78 70 77 -0.030 2.50 0.020

193 28.228 28.281 0.15 0.15 1.83 79 -1.00 1.26 79 -3.30 83 0.050 101 100 4.2 0.0 231 78 72 78 70 77 -0.029 1.33 0.080

194 28.376 28.429 0.15 0.15 1.82 79 -0.66 1.25 79 -3.30 84 0.050 101 101 4.2 0.0 231 78 72 78 70 77 -0.029 2.67 0.010

195 28.524 28.575 0.15 0.15 1.82 79 -0.93 1.27 79 -3.10 84 0.050 101 100 4.2 0.0 229 78 72 78 71 77 -0.030 2.86 0.010

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Data EntryPage 22 of 68

Page 23: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc

Pellet Heater Test Data - ASTM E2779 / ASTM E2515PM Control Modules: 371/372

Run: 1 Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 14.22 ft/sec.

Travis High Burn End Time: 60 Dilution Tunnel MW(wet): 28.78 lb/lb-mole Intial Tunnel Flow: 156.8 scfm

AGP PS Medium Burn End Time: 180 Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 156.8 scfm

2308 360 min Dilution Tunnel Static: -0.150 "H2O Post-Test Leak Check (1): 0.000 cfm @ -6 in. Hg

0028PS108E Recording Interval: 1 min Tunnel Area: 0.1963 ft2

Post-Test Leak Check (2): 0.000 cfm @ -9 in. Hg

29-Aug-18 Pitot Tube Cp: 0.99 Fuel Moisture (%): 4.004 Dry Basis 3.850 Wet Basis

09:11 Background Sample Volume: 0 cubic feet 4.004 3.707

Meter Box Y Factor: 0.997 (1) 0.981 (2) 0 (Amb) Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

Initial dP 0.042 0.046 0.046 0.042 0.044 0.046 0.042 0.044 0.050 "H2O

Barometric Pressure: Begin Middle End Average Temp: 83 83 83 83 83 83 83 83 83 °F

29.36 29.37 29.37 29.37 "Hg Vstrav 14.23 ft/sec Vscent 15.17 ft/sec Fp 0.938

Particulate Sampling Data

Elapsed

Time

(min)

Gas Meter

1 (ft3)

Gas Meter

2 (ft3)

Sample

Rate 1

(cfm)

Sample

Rate 2

(cfm)

Orifice

dH 1

("H2O)

Meter

Temp 1

(°F)

Meter

Vacuum 1

("Hg)

Orifice

dH 2

("H2O)

Meter

Temp 2

(°F)

Meter

Vacuum 2

("Hg)

Dilution

Tunnel (°F)

Tunnel

Center

dP

Pro. Rate

1

Pro. Rate

2

Scale

Reading

Weight

ChangeStack Filter 1 Dryer 1 Filter 2 Dryer 2 Ambient

Draft

("H2O)CO2 (%) CO (%)

Temperature Data (°F) Stack Gas Data

Velocity Traverse Data

Fuel Weight (lb)

Manufacturer:

Model:

Tracking No.:

Beginning Clock Time:

Total Sampling Time:

Project No.:

Test Date:

Export all Sheets to

196 28.672 28.723 0.15 0.15 1.83 79 -1.03 1.27 79 -3.00 84 0.050 101 101 4.1 0.0 227 78 72 78 71 77 -0.028 1.67 0.050

197 28.820 28.870 0.15 0.15 1.82 79 -0.56 1.26 79 -3.20 84 0.050 101 100 4.1 0.0 226 78 72 78 71 77 -0.029 2.19 0.030

198 28.968 29.017 0.15 0.15 1.82 79 -0.95 1.27 79 -3.30 84 0.050 101 100 4.1 0.0 225 78 72 78 71 77 -0.028 3.19 0.010

199 29.116 29.164 0.15 0.15 1.83 79 -0.55 1.26 79 -3.00 84 0.050 101 100 4.0 0.0 223 78 72 78 71 77 -0.029 2.16 0.020

200 29.264 29.312 0.15 0.15 1.81 79 -0.68 1.26 79 -3.10 84 0.050 101 101 4.0 0.0 223 78 72 78 71 77 -0.028 1.99 0.020

201 29.412 29.458 0.15 0.15 1.83 80 -0.58 1.27 79 -3.30 84 0.050 101 100 4.0 0.0 223 78 72 78 71 77 -0.028 3.40 0.010

202 29.560 29.605 0.15 0.15 1.84 80 -0.61 1.27 79 -3.40 84 0.050 101 100 4.0 0.0 221 78 72 78 71 77 -0.029 1.92 0.050

203 29.708 29.753 0.15 0.15 1.83 80 -0.56 1.27 79 -3.20 84 0.050 101 101 3.9 0.0 220 78 72 78 71 77 -0.027 1.62 0.050

204 29.856 29.900 0.15 0.15 1.83 80 -0.75 1.27 79 -3.20 84 0.050 101 100 3.9 0.0 220 78 72 78 71 77 -0.028 3.03 0.010

205 30.004 30.047 0.15 0.15 1.84 80 -0.55 1.27 79 -3.10 85 0.050 101 100 3.9 0.0 219 78 72 78 71 77 -0.028 2.63 0.010

206 30.152 30.194 0.15 0.15 1.84 80 -0.99 1.27 79 -3.40 85 0.050 101 100 3.9 0.0 217 78 72 78 71 77 -0.026 1.33 0.060

207 30.300 30.341 0.15 0.15 1.84 80 -0.57 1.26 80 -3.40 85 0.050 101 100 3.9 0.0 216 78 72 78 71 77 -0.027 2.31 0.020

208 30.447 30.488 0.15 0.15 1.83 80 -0.99 1.27 80 -3.40 85 0.050 100 100 3.8 0.0 216 78 72 78 71 77 -0.026 2.46 0.010

209 30.595 30.636 0.15 0.15 1.84 80 -1.03 1.27 80 -3.10 85 0.050 101 101 3.8 0.0 214 78 72 78 71 77 -0.026 1.51 0.040

210 30.743 30.783 0.15 0.15 1.83 80 -0.69 1.27 80 -3.10 85 0.050 101 100 3.8 0.0 214 78 72 78 71 77 -0.027 2.64 0.020

211 30.891 30.930 0.15 0.15 1.82 80 -0.81 1.27 80 -3.10 85 0.050 101 100 3.8 0.0 214 78 72 78 71 77 -0.025 2.67 0.010

212 31.039 31.077 0.15 0.15 1.83 80 -0.97 1.26 80 -3.30 85 0.050 101 100 3.7 0.0 212 78 72 78 71 77 -0.026 1.56 0.050

213 31.187 31.225 0.15 0.15 1.82 80 -0.79 1.26 80 -3.10 85 0.050 101 101 3.7 0.0 212 78 72 78 71 77 -0.026 1.92 0.030

214 31.335 31.371 0.15 0.15 1.83 81 -0.56 1.28 80 -3.20 85 0.050 101 100 3.7 0.0 212 78 72 78 71 77 -0.026 2.82 0.010

215 31.483 31.519 0.15 0.15 1.82 81 -0.61 1.28 80 -3.30 85 0.050 101 101 3.7 0.0 210 78 73 78 71 78 -0.026 1.59 0.050

216 31.632 31.666 0.15 0.15 1.82 81 -1.01 1.26 80 -3.30 85 0.050 101 100 3.6 0.0 209 78 73 79 71 77 -0.025 1.30 0.050

217 31.780 31.814 0.15 0.15 1.81 81 -0.99 1.27 80 -3.30 85 0.050 101 101 3.6 0.0 210 78 73 78 71 78 -0.026 2.79 0.010

218 31.928 31.961 0.15 0.15 1.82 81 -1.01 1.26 80 -3.30 85 0.050 101 100 3.6 0.0 209 78 73 78 71 78 -0.024 2.27 0.010

219 32.076 32.108 0.15 0.15 1.82 81 -0.80 1.26 80 -3.30 85 0.050 101 100 3.5 0.0 208 78 73 78 71 78 -0.025 1.56 0.040

220 32.224 32.255 0.15 0.15 1.83 81 -0.95 1.27 80 -3.20 85 0.050 101 100 3.5 0.0 208 78 73 78 71 78 -0.025 2.79 0.020

221 32.373 32.402 0.15 0.15 1.81 81 -0.90 1.27 80 -3.40 85 0.050 101 100 3.5 0.0 208 78 73 78 71 78 -0.025 2.29 0.010

222 32.521 32.550 0.15 0.15 1.83 81 -0.74 1.27 80 -3.30 85 0.050 101 101 3.4 0.0 206 78 73 78 71 78 -0.024 1.28 0.060

223 32.669 32.698 0.15 0.15 1.83 81 -1.04 1.26 81 -3.40 85 0.050 101 101 3.4 0.0 206 78 73 79 72 78 -0.025 2.13 0.010

224 32.817 32.845 0.15 0.15 1.82 81 -0.66 1.27 81 -3.20 85 0.050 101 100 3.4 0.0 206 78 73 78 71 78 -0.025 2.35 0.010

225 32.965 32.992 0.15 0.15 1.82 81 -1.01 1.27 81 -3.30 85 0.050 101 100 3.4 0.0 205 78 73 79 72 78 -0.024 1.68 0.040

226 33.113 33.139 0.15 0.15 1.84 81 -0.65 1.27 81 -3.50 85 0.050 101 100 3.3 0.0 204 78 73 78 72 78 -0.024 1.38 0.040

227 33.261 33.286 0.15 0.15 1.84 81 -0.79 1.27 81 -3.20 85 0.050 101 100 3.3 0.0 204 78 73 79 72 78 -0.025 2.68 0.010

228 33.409 33.434 0.15 0.15 1.83 81 -0.99 1.27 81 -3.30 85 0.050 101 101 3.3 0.0 203 78 73 79 72 78 -0.024 1.86 0.020

229 33.557 33.582 0.15 0.15 1.83 81 -0.69 1.27 81 -3.40 85 0.050 101 101 3.2 0.0 204 78 73 79 72 78 -0.023 1.85 0.020

230 33.705 33.729 0.15 0.15 1.84 82 -1.02 1.27 81 -3.20 85 0.050 100 100 3.2 0.0 204 78 73 78 72 78 -0.024 2.34 0.010

231 33.853 33.876 0.15 0.15 1.83 82 -0.89 1.27 81 -3.40 85 0.050 100 100 3.2 0.0 204 78 73 79 72 78 -0.024 2.08 0.010

232 34.001 34.024 0.15 0.15 1.83 82 -0.58 1.27 81 -3.40 85 0.050 100 101 3.2 0.0 205 78 73 79 72 78 -0.024 1.16 0.070

233 34.149 34.170 0.15 0.15 1.82 82 -1.01 1.27 81 -3.50 85 0.050 100 99 3.1 0.0 204 78 73 79 72 78 -0.024 2.27 0.010

234 34.297 34.318 0.15 0.15 1.82 82 -0.79 1.27 81 -3.50 85 0.050 100 101 3.1 0.0 203 78 73 79 72 77 -0.025 2.44 0.010

235 34.445 34.466 0.15 0.15 1.82 82 -0.98 1.27 81 -3.50 85 0.050 100 101 3.1 0.0 201 78 73 79 72 78 -0.023 1.42 0.030

236 34.594 34.613 0.15 0.15 1.81 82 -0.66 1.27 81 -3.60 85 0.050 101 100 3.1 0.0 201 78 73 79 72 78 -0.024 2.19 0.020

237 34.742 34.760 0.15 0.15 1.81 82 -1.01 1.26 81 -3.30 85 0.050 100 100 3.1 0.0 201 78 73 79 72 78 -0.024 2.45 0.010

238 34.890 34.908 0.15 0.15 1.81 82 -0.83 1.26 81 -3.30 85 0.050 100 101 3.0 0.0 201 78 73 79 72 78 -0.023 1.89 0.020

239 35.038 35.054 0.15 0.15 1.81 82 -1.01 1.27 81 -3.40 85 0.050 100 99 3.0 0.0 201 78 73 79 72 78 -0.024 1.96 0.020

240 35.186 35.202 0.15 0.15 1.82 82 -0.63 1.27 81 -3.40 85 0.050 100 101 3.0 0.0 201 78 74 79 72 78 -0.024 2.33 0.000

241 35.334 35.350 0.15 0.15 1.83 82 -0.57 1.27 81 -3.30 85 0.050 100 101 3.0 0.0 200 78 74 79 72 78 -0.024 1.40 0.040

242 35.483 35.497 0.15 0.15 1.82 82 -0.59 1.27 81 -3.60 85 0.050 101 100 2.9 0.0 200 78 74 79 72 78 -0.023 1.50 0.050

243 35.631 35.644 0.15 0.15 1.83 82 -0.88 1.26 82 -3.50 85 0.050 100 100 2.9 0.0 200 78 74 79 72 78 -0.024 2.81 0.010

244 35.779 35.792 0.15 0.15 1.82 82 -1.04 1.26 82 -3.30 85 0.050 100 101 2.9 0.0 199 78 74 79 72 78 -0.023 2.13 0.010

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Data EntryPage 23 of 68

Page 24: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc

Pellet Heater Test Data - ASTM E2779 / ASTM E2515PM Control Modules: 371/372

Run: 1 Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 14.22 ft/sec.

Travis High Burn End Time: 60 Dilution Tunnel MW(wet): 28.78 lb/lb-mole Intial Tunnel Flow: 156.8 scfm

AGP PS Medium Burn End Time: 180 Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 156.8 scfm

2308 360 min Dilution Tunnel Static: -0.150 "H2O Post-Test Leak Check (1): 0.000 cfm @ -6 in. Hg

0028PS108E Recording Interval: 1 min Tunnel Area: 0.1963 ft2

Post-Test Leak Check (2): 0.000 cfm @ -9 in. Hg

29-Aug-18 Pitot Tube Cp: 0.99 Fuel Moisture (%): 4.004 Dry Basis 3.850 Wet Basis

09:11 Background Sample Volume: 0 cubic feet 4.004 3.707

Meter Box Y Factor: 0.997 (1) 0.981 (2) 0 (Amb) Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

Initial dP 0.042 0.046 0.046 0.042 0.044 0.046 0.042 0.044 0.050 "H2O

Barometric Pressure: Begin Middle End Average Temp: 83 83 83 83 83 83 83 83 83 °F

29.36 29.37 29.37 29.37 "Hg Vstrav 14.23 ft/sec Vscent 15.17 ft/sec Fp 0.938

Particulate Sampling Data

Elapsed

Time

(min)

Gas Meter

1 (ft3)

Gas Meter

2 (ft3)

Sample

Rate 1

(cfm)

Sample

Rate 2

(cfm)

Orifice

dH 1

("H2O)

Meter

Temp 1

(°F)

Meter

Vacuum 1

("Hg)

Orifice

dH 2

("H2O)

Meter

Temp 2

(°F)

Meter

Vacuum 2

("Hg)

Dilution

Tunnel (°F)

Tunnel

Center

dP

Pro. Rate

1

Pro. Rate

2

Scale

Reading

Weight

ChangeStack Filter 1 Dryer 1 Filter 2 Dryer 2 Ambient

Draft

("H2O)CO2 (%) CO (%)

Temperature Data (°F) Stack Gas Data

Velocity Traverse Data

Fuel Weight (lb)

Manufacturer:

Model:

Tracking No.:

Beginning Clock Time:

Total Sampling Time:

Project No.:

Test Date:

Export all Sheets to

245 35.927 35.938 0.15 0.15 1.83 82 -0.61 1.27 82 -3.20 85 0.050 100 99 2.9 0.0 199 78 74 78 72 78 -0.024 1.35 0.040

246 36.074 36.086 0.15 0.15 1.84 82 -0.86 1.27 82 -3.20 85 0.050 100 101 2.8 0.0 200 78 74 79 72 78 -0.023 2.34 0.010

247 36.222 36.234 0.15 0.15 1.83 82 -1.04 1.27 82 -3.20 85 0.050 100 101 2.8 0.0 199 78 74 79 72 78 -0.023 2.01 0.010

248 36.371 36.380 0.15 0.15 1.83 82 -1.01 1.27 82 -3.50 85 0.050 101 99 2.8 0.0 199 78 74 79 72 78 -0.023 1.33 0.040

249 36.519 36.528 0.15 0.15 1.83 82 -0.61 1.26 82 -3.40 85 0.050 100 101 2.7 0.0 199 78 74 79 72 78 -0.023 2.62 0.010

250 36.667 36.675 0.15 0.15 1.83 82 -1.05 1.27 82 -3.20 85 0.050 100 100 2.7 0.0 200 78 74 78 72 78 -0.023 2.74 0.000

251 36.815 36.822 0.15 0.15 1.83 83 -0.58 1.27 82 -3.20 85 0.050 100 100 2.7 0.0 199 78 74 79 73 78 -0.024 1.33 0.050

252 36.963 36.970 0.15 0.15 1.81 83 -0.99 1.27 82 -3.20 85 0.050 100 101 2.7 0.0 200 78 74 79 73 78 -0.023 2.43 0.010

253 37.111 37.117 0.15 0.15 1.82 83 -0.57 1.26 82 -3.40 85 0.050 100 100 2.6 0.0 200 78 74 79 73 78 -0.024 2.44 0.010

254 37.259 37.265 0.15 0.15 1.81 83 -1.02 1.27 82 -3.30 84 0.050 100 100 2.6 0.0 199 78 74 78 73 78 -0.024 1.72 0.030

255 37.407 37.412 0.15 0.15 1.81 83 -1.01 1.26 82 -3.40 84 0.050 100 100 2.6 0.0 199 78 74 78 73 78 -0.023 1.28 0.040

256 37.555 37.560 0.15 0.15 1.81 83 -1.04 1.26 82 -3.10 84 0.050 100 100 2.6 0.0 199 78 74 79 73 78 -0.024 2.27 0.000

257 37.704 37.707 0.15 0.15 1.81 83 -0.92 1.27 82 -3.20 84 0.050 101 100 2.6 0.0 199 78 74 79 73 78 -0.024 2.46 0.000

258 37.852 37.854 0.15 0.15 1.80 83 -0.68 1.27 82 -3.30 84 0.050 100 100 2.5 0.0 199 78 74 79 73 78 -0.023 1.85 0.010

259 38.000 38.002 0.15 0.15 1.82 83 -1.04 1.26 82 -3.30 84 0.050 100 100 2.5 0.0 200 78 74 79 73 78 -0.024 2.92 0.010

260 38.148 38.149 0.15 0.15 1.83 83 -1.04 1.27 82 -3.10 84 0.050 100 100 2.5 0.0 200 78 75 78 73 78 -0.024 2.27 0.010

261 38.296 38.296 0.15 0.15 1.83 83 -1.05 1.26 82 -3.40 85 0.050 100 100 2.5 0.0 199 78 75 78 73 78 -0.023 1.19 0.040

262 38.445 38.443 0.15 0.15 1.81 83 -0.64 1.26 82 -3.40 85 0.050 101 100 2.5 0.0 200 78 75 78 73 78 -0.023 2.19 0.010

263 38.593 38.590 0.15 0.15 1.83 83 -0.98 1.27 82 -3.30 84 0.050 100 100 2.4 0.0 200 78 75 79 73 78 -0.025 2.54 0.010

264 38.740 38.738 0.15 0.15 1.81 83 -0.89 1.27 82 -3.10 85 0.050 100 101 2.4 0.0 199 78 75 79 73 78 -0.023 1.44 0.030

265 38.888 38.885 0.15 0.15 1.83 83 -0.74 1.26 82 -3.40 85 0.050 100 100 2.4 0.0 199 78 75 79 73 78 -0.024 1.56 0.030

266 39.036 39.033 0.15 0.15 1.83 83 -0.59 1.26 82 -3.10 85 0.050 100 101 2.4 0.0 200 78 75 78 73 78 -0.025 2.93 0.000

267 39.184 39.180 0.15 0.15 1.82 83 -0.65 1.26 82 -3.30 85 0.050 100 100 2.4 0.0 199 78 75 79 73 78 -0.025 1.91 0.010

268 39.332 39.327 0.15 0.15 1.83 83 -0.59 1.26 82 -3.10 85 0.050 100 100 2.3 0.0 199 78 75 78 73 78 -0.023 1.86 0.010

269 39.480 39.474 0.15 0.15 1.83 83 -0.59 1.27 82 -3.40 84 0.050 100 100 2.3 0.0 200 78 75 78 73 78 -0.023 2.26 0.010

270 39.628 39.621 0.15 0.15 1.82 83 -0.73 1.27 82 -3.20 84 0.050 100 100 2.3 0.0 199 78 75 79 73 78 -0.023 1.97 0.010

271 39.776 39.769 0.15 0.15 1.83 83 -1.06 1.27 82 -3.10 85 0.050 100 101 2.3 0.0 199 78 75 78 73 78 -0.023 1.34 0.050

272 39.924 39.917 0.15 0.15 1.82 83 -1.01 1.26 82 -3.20 85 0.050 100 101 2.2 0.0 199 78 75 79 73 78 -0.023 2.13 0.020

273 40.073 40.063 0.15 0.15 1.82 83 -1.03 1.27 82 -3.10 85 0.050 101 99 2.2 0.0 199 78 75 79 73 78 -0.023 2.62 0.000

274 40.221 40.211 0.15 0.15 1.81 83 -0.87 1.27 82 -3.10 84 0.050 100 100 2.2 0.0 198 78 75 79 73 78 -0.022 1.42 0.030

275 40.369 40.358 0.15 0.15 1.81 83 -0.59 1.26 82 -3.40 84 0.050 100 100 2.2 0.0 198 78 75 79 74 78 -0.023 1.90 0.020

276 40.517 40.505 0.15 0.15 1.81 83 -0.73 1.27 82 -3.10 84 0.050 100 100 2.1 0.0 199 78 75 79 74 78 -0.023 3.21 0.000

277 40.665 40.653 0.15 0.15 1.80 83 -1.04 1.27 83 -3.20 84 0.050 100 100 2.1 0.0 199 78 75 79 74 78 -0.024 1.72 0.020

278 40.813 40.800 0.15 0.15 1.80 83 -0.68 1.26 83 -3.40 84 0.050 100 100 2.1 0.0 200 78 76 78 74 78 -0.023 2.41 0.010

279 40.962 40.947 0.15 0.15 1.82 83 -0.63 1.27 83 -3.10 84 0.050 101 100 2.0 0.0 200 78 76 79 74 78 -0.024 2.57 0.000

280 41.110 41.094 0.15 0.15 1.83 83 -0.98 1.26 83 -3.10 84 0.050 100 100 2.0 0.0 199 78 76 78 74 78 -0.024 1.40 0.050

281 41.258 41.242 0.15 0.15 1.81 83 -1.06 1.25 83 -3.40 84 0.050 100 100 2.0 0.0 199 78 76 78 74 78 -0.023 1.50 0.030

282 41.406 41.389 0.15 0.15 1.82 83 -0.58 1.27 83 -3.20 84 0.050 100 100 2.0 0.0 199 78 76 79 74 78 -0.024 2.52 0.000

283 41.554 41.536 0.15 0.15 1.82 83 -0.60 1.27 83 -3.40 84 0.050 100 100 1.9 0.0 199 78 76 79 74 78 -0.023 2.29 0.000

284 41.702 41.684 0.15 0.15 1.83 83 -0.95 1.27 83 -3.20 84 0.050 100 100 1.9 0.0 198 78 76 79 74 78 -0.023 1.20 0.050

285 41.850 41.831 0.15 0.15 1.83 83 -0.62 1.27 83 -3.30 84 0.050 100 100 1.9 0.0 198 78 76 79 74 78 -0.024 2.07 0.010

286 41.998 41.978 0.15 0.15 1.83 83 -0.66 1.26 83 -3.50 84 0.050 100 100 1.9 0.0 198 78 76 78 74 78 -0.023 2.21 0.000

287 42.146 42.125 0.15 0.15 1.83 83 -0.63 1.26 83 -3.30 84 0.050 100 100 1.9 0.0 198 78 76 79 74 78 -0.023 1.69 0.020

288 42.294 42.272 0.15 0.15 1.83 83 -1.00 1.27 83 -3.20 84 0.050 100 100 1.8 0.0 199 78 76 79 74 78 -0.023 2.18 0.000

289 42.442 42.420 0.15 0.15 1.83 83 -1.05 1.27 83 -3.10 84 0.050 100 100 1.8 0.0 198 78 76 79 74 78 -0.024 2.29 0.000

290 42.590 42.567 0.15 0.15 1.82 84 -0.88 1.27 83 -3.20 85 0.050 100 100 1.8 0.0 197 78 76 79 74 78 -0.023 1.67 0.020

291 42.738 42.714 0.15 0.15 1.81 84 -0.81 1.26 83 -3.30 85 0.050 100 100 1.8 0.0 198 78 76 79 74 78 -0.024 1.84 0.010

292 42.886 42.861 0.15 0.15 1.81 84 -0.95 1.26 83 -3.00 84 0.050 100 100 1.7 0.0 198 78 77 79 74 78 -0.024 2.52 0.000

293 43.034 43.009 0.15 0.15 1.81 84 -1.05 1.26 83 -3.10 84 0.050 100 100 1.7 0.0 198 78 77 78 74 78 -0.023 1.96 0.000

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Data EntryPage 24 of 68

Page 25: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc

Pellet Heater Test Data - ASTM E2779 / ASTM E2515PM Control Modules: 371/372

Run: 1 Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 14.22 ft/sec.

Travis High Burn End Time: 60 Dilution Tunnel MW(wet): 28.78 lb/lb-mole Intial Tunnel Flow: 156.8 scfm

AGP PS Medium Burn End Time: 180 Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 156.8 scfm

2308 360 min Dilution Tunnel Static: -0.150 "H2O Post-Test Leak Check (1): 0.000 cfm @ -6 in. Hg

0028PS108E Recording Interval: 1 min Tunnel Area: 0.1963 ft2

Post-Test Leak Check (2): 0.000 cfm @ -9 in. Hg

29-Aug-18 Pitot Tube Cp: 0.99 Fuel Moisture (%): 4.004 Dry Basis 3.850 Wet Basis

09:11 Background Sample Volume: 0 cubic feet 4.004 3.707

Meter Box Y Factor: 0.997 (1) 0.981 (2) 0 (Amb) Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

Initial dP 0.042 0.046 0.046 0.042 0.044 0.046 0.042 0.044 0.050 "H2O

Barometric Pressure: Begin Middle End Average Temp: 83 83 83 83 83 83 83 83 83 °F

29.36 29.37 29.37 29.37 "Hg Vstrav 14.23 ft/sec Vscent 15.17 ft/sec Fp 0.938

Particulate Sampling Data

Elapsed

Time

(min)

Gas Meter

1 (ft3)

Gas Meter

2 (ft3)

Sample

Rate 1

(cfm)

Sample

Rate 2

(cfm)

Orifice

dH 1

("H2O)

Meter

Temp 1

(°F)

Meter

Vacuum 1

("Hg)

Orifice

dH 2

("H2O)

Meter

Temp 2

(°F)

Meter

Vacuum 2

("Hg)

Dilution

Tunnel (°F)

Tunnel

Center

dP

Pro. Rate

1

Pro. Rate

2

Scale

Reading

Weight

ChangeStack Filter 1 Dryer 1 Filter 2 Dryer 2 Ambient

Draft

("H2O)CO2 (%) CO (%)

Temperature Data (°F) Stack Gas Data

Velocity Traverse Data

Fuel Weight (lb)

Manufacturer:

Model:

Tracking No.:

Beginning Clock Time:

Total Sampling Time:

Project No.:

Test Date:

Export all Sheets to

294 43.182 43.156 0.15 0.15 1.80 84 -0.58 1.27 83 -3.20 84 0.050 100 100 1.7 0.0 197 78 77 78 74 78 -0.023 1.17 0.060

295 43.330 43.303 0.15 0.15 1.81 84 -0.89 1.26 83 -3.30 84 0.050 100 100 1.7 0.0 198 78 77 78 74 78 -0.024 2.01 0.010

296 43.479 43.450 0.15 0.15 1.80 84 -0.69 1.27 83 -3.30 85 0.050 101 100 1.6 0.0 198 78 77 78 74 78 -0.025 2.54 0.000

297 43.627 43.598 0.15 0.15 1.80 84 -0.63 1.26 83 -3.00 84 0.050 100 100 1.6 0.0 198 78 77 78 75 78 -0.023 1.64 0.010

298 43.775 43.744 0.15 0.15 1.81 84 -0.73 1.26 83 -3.00 85 0.050 100 99 1.6 0.0 198 78 77 79 75 78 -0.023 2.10 0.020

299 43.923 43.892 0.15 0.15 1.83 84 -0.74 1.26 83 -3.10 84 0.050 100 100 1.5 0.0 199 78 77 78 75 78 -0.024 2.42 0.000

300 44.071 44.039 0.15 0.15 1.82 84 -0.59 1.26 83 -3.20 84 0.050 100 100 1.5 0.0 198 78 77 78 75 78 -0.022 1.53 0.030

301 44.219 44.186 0.15 0.15 1.82 84 -0.93 1.26 83 -2.90 84 0.050 100 100 1.5 0.0 199 78 77 79 75 78 -0.024 1.99 0.010

302 44.367 44.334 0.15 0.15 1.82 84 -0.61 1.27 83 -3.00 84 0.050 100 100 1.4 0.0 199 78 77 78 75 78 -0.024 2.68 0.000

303 44.515 44.481 0.15 0.15 1.81 84 -0.73 1.27 83 -3.10 84 0.050 100 100 1.4 0.0 198 78 77 78 75 78 -0.022 1.63 0.020

304 44.663 44.628 0.15 0.15 1.83 84 -0.80 1.26 83 -2.90 84 0.050 100 100 1.4 0.0 198 78 77 78 75 78 -0.024 1.59 0.020

305 44.810 44.775 0.15 0.15 1.82 84 -0.78 1.26 83 -3.00 84 0.050 99 100 1.4 0.0 199 78 77 78 75 78 -0.023 2.71 0.000

306 44.958 44.923 0.15 0.15 1.82 84 -0.61 1.26 83 -3.10 84 0.050 100 100 1.3 0.0 199 78 77 79 75 78 -0.024 2.14 0.000

307 45.107 45.070 0.15 0.15 1.83 84 -0.76 1.27 83 -3.00 84 0.050 101 100 1.3 0.0 198 78 77 78 75 78 -0.023 1.17 0.040

308 45.254 45.217 0.15 0.15 1.82 84 -1.06 1.27 83 -3.20 84 0.050 99 100 1.3 0.0 198 78 77 79 75 78 -0.023 2.55 0.010

309 45.402 45.365 0.15 0.15 1.82 84 -0.94 1.27 83 -2.90 84 0.050 100 100 1.2 0.0 199 78 77 78 75 78 -0.023 2.70 -0.010

310 45.551 45.512 0.15 0.15 1.82 84 -0.61 1.27 83 -2.90 84 0.050 101 100 1.2 0.0 199 78 77 79 75 78 -0.023 1.63 0.030

311 45.699 45.659 0.15 0.15 1.81 84 -0.87 1.25 83 -3.20 84 0.050 100 100 1.2 0.0 200 78 77 78 75 78 -0.025 2.63 0.000

312 45.847 45.806 0.15 0.15 1.80 84 -0.60 1.26 83 -3.00 84 0.050 100 100 1.2 0.0 200 78 77 78 75 78 -0.024 2.23 0.000

313 45.994 45.953 0.15 0.15 1.81 84 -0.93 1.27 83 -2.90 84 0.050 99 100 1.1 0.0 199 78 77 78 75 78 -0.023 1.31 0.050

314 46.142 46.100 0.15 0.15 1.81 84 -0.73 1.26 83 -2.90 84 0.050 100 100 1.1 0.0 200 78 77 78 75 78 -0.024 1.86 0.010

315 46.291 46.248 0.15 0.15 1.80 84 -1.07 1.27 83 -2.90 84 0.050 101 100 1.1 0.0 200 78 78 78 75 78 -0.024 2.47 0.000

316 46.439 46.395 0.15 0.15 1.80 84 -0.96 1.26 83 -3.20 84 0.050 100 100 1.1 0.0 199 78 78 78 75 78 -0.023 1.95 0.010

317 46.587 46.542 0.15 0.15 1.82 84 -0.66 1.26 83 -3.00 84 0.050 100 100 1.1 0.0 199 78 78 78 75 78 -0.023 1.61 0.030

318 46.735 46.689 0.15 0.15 1.80 84 -0.61 1.26 83 -3.20 84 0.050 100 100 1.0 0.0 199 78 78 78 75 78 -0.024 2.30 0.000

319 46.883 46.837 0.15 0.15 1.82 84 -0.60 1.26 83 -2.90 84 0.050 100 100 1.0 0.0 199 78 78 79 75 78 -0.024 2.20 0.000

320 47.031 46.983 0.15 0.15 1.83 84 -0.81 1.26 83 -2.90 84 0.050 100 99 1.0 0.0 199 78 78 78 75 78 -0.023 1.85 0.010

321 47.179 47.131 0.15 0.15 1.82 84 -0.98 1.26 83 -2.90 84 0.050 100 100 1.0 0.0 200 78 78 78 75 78 -0.024 2.46 0.000

322 47.327 47.278 0.15 0.15 1.82 84 -0.64 1.26 83 -3.20 84 0.050 100 100 1.0 0.0 200 78 78 78 75 78 -0.024 2.59 0.000

323 47.475 47.425 0.15 0.15 1.82 84 -1.05 1.26 83 -2.90 84 0.050 100 100 0.9 0.0 199 78 78 78 75 78 -0.023 1.25 0.050

324 47.622 47.572 0.15 0.15 1.82 84 -1.07 1.26 83 -3.00 84 0.050 99 100 0.9 0.0 200 78 78 78 75 78 -0.024 2.05 0.000

325 47.770 47.720 0.15 0.15 1.82 84 -0.79 1.25 83 -3.00 84 0.050 100 100 0.9 0.0 200 78 78 78 75 78 -0.025 2.42 0.000

326 47.918 47.866 0.15 0.15 1.82 84 -0.59 1.27 83 -2.90 84 0.050 100 99 0.9 0.0 199 78 78 78 75 78 -0.023 1.61 0.030

327 48.066 48.014 0.15 0.15 1.82 84 -0.63 1.26 83 -3.20 84 0.050 100 100 0.9 0.0 199 78 78 78 75 78 -0.023 1.66 0.020

328 48.214 48.161 0.15 0.15 1.83 84 -0.94 1.26 83 -3.20 84 0.050 100 100 0.8 0.0 200 78 78 78 75 78 -0.024 3.14 0.000

329 48.362 48.308 0.15 0.15 1.82 84 -1.06 1.27 83 -3.20 84 0.050 100 100 0.8 0.0 199 78 78 78 75 78 -0.024 2.20 0.000

330 48.509 48.455 0.15 0.15 1.82 84 -0.61 1.25 83 -3.20 84 0.050 99 100 0.8 0.0 200 78 78 78 75 78 -0.024 2.13 0.010

331 48.657 48.602 0.15 0.15 1.81 84 -1.05 1.26 83 -3.10 84 0.050 100 100 0.8 0.0 201 78 78 78 75 78 -0.024 2.41 0.000

332 48.805 48.750 0.15 0.15 1.82 84 -0.61 1.27 83 -3.10 84 0.050 100 100 0.7 0.0 200 78 77 78 75 78 -0.025 1.82 0.020

333 48.953 48.896 0.15 0.15 1.80 84 -0.92 1.26 83 -3.10 84 0.050 100 99 0.7 0.0 200 78 77 79 75 78 -0.023 1.38 0.040

334 49.101 49.044 0.15 0.15 1.80 84 -1.00 1.26 83 -3.20 84 0.050 100 100 0.7 0.0 200 78 77 78 75 78 -0.024 2.39 0.010

335 49.248 49.191 0.15 0.15 1.81 84 -1.05 1.26 83 -3.10 84 0.050 99 100 0.7 0.0 200 78 77 78 75 78 -0.025 2.62 0.000

336 49.396 49.338 0.15 0.15 1.81 84 -1.07 1.26 83 -2.90 84 0.050 100 100 0.6 0.0 199 78 77 78 75 78 -0.025 1.19 0.040

337 49.544 49.485 0.15 0.15 1.80 84 -0.91 1.26 83 -3.20 84 0.050 100 100 0.6 0.0 199 78 77 78 75 78 -0.023 1.98 0.010

338 49.692 49.632 0.15 0.15 1.80 84 -0.78 1.25 83 -2.90 84 0.050 100 100 0.6 0.0 200 78 77 78 75 78 -0.024 2.74 0.000

339 49.840 49.779 0.15 0.15 1.80 84 -0.70 1.26 83 -3.10 84 0.050 100 100 0.5 0.0 200 78 76 78 74 78 -0.024 1.76 0.020

340 49.988 49.926 0.15 0.15 1.79 84 -0.98 1.26 83 -3.10 84 0.050 100 100 0.5 0.0 200 78 76 78 74 78 -0.024 2.03 0.000

341 50.136 50.073 0.15 0.15 1.81 84 -0.83 1.26 83 -3.00 84 0.050 100 100 0.5 0.0 201 78 76 78 74 78 -0.025 2.60 0.000

342 50.283 50.221 0.15 0.15 1.80 84 -1.05 1.27 83 -3.00 84 0.050 99 100 0.4 0.0 200 78 76 78 74 78 -0.023 1.72 0.020

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Data EntryPage 25 of 68

Page 26: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc

Pellet Heater Test Data - ASTM E2779 / ASTM E2515PM Control Modules: 371/372

Run: 1 Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 14.22 ft/sec.

Travis High Burn End Time: 60 Dilution Tunnel MW(wet): 28.78 lb/lb-mole Intial Tunnel Flow: 156.8 scfm

AGP PS Medium Burn End Time: 180 Dilution Tunnel H2O: 2.00 percent Average Tunnel Flow: 156.8 scfm

2308 360 min Dilution Tunnel Static: -0.150 "H2O Post-Test Leak Check (1): 0.000 cfm @ -6 in. Hg

0028PS108E Recording Interval: 1 min Tunnel Area: 0.1963 ft2

Post-Test Leak Check (2): 0.000 cfm @ -9 in. Hg

29-Aug-18 Pitot Tube Cp: 0.99 Fuel Moisture (%): 4.004 Dry Basis 3.850 Wet Basis

09:11 Background Sample Volume: 0 cubic feet 4.004 3.707

Meter Box Y Factor: 0.997 (1) 0.981 (2) 0 (Amb) Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center

Initial dP 0.042 0.046 0.046 0.042 0.044 0.046 0.042 0.044 0.050 "H2O

Barometric Pressure: Begin Middle End Average Temp: 83 83 83 83 83 83 83 83 83 °F

29.36 29.37 29.37 29.37 "Hg Vstrav 14.23 ft/sec Vscent 15.17 ft/sec Fp 0.938

Particulate Sampling Data

Elapsed

Time

(min)

Gas Meter

1 (ft3)

Gas Meter

2 (ft3)

Sample

Rate 1

(cfm)

Sample

Rate 2

(cfm)

Orifice

dH 1

("H2O)

Meter

Temp 1

(°F)

Meter

Vacuum 1

("Hg)

Orifice

dH 2

("H2O)

Meter

Temp 2

(°F)

Meter

Vacuum 2

("Hg)

Dilution

Tunnel (°F)

Tunnel

Center

dP

Pro. Rate

1

Pro. Rate

2

Scale

Reading

Weight

ChangeStack Filter 1 Dryer 1 Filter 2 Dryer 2 Ambient

Draft

("H2O)CO2 (%) CO (%)

Temperature Data (°F) Stack Gas Data

Velocity Traverse Data

Fuel Weight (lb)

Manufacturer:

Model:

Tracking No.:

Beginning Clock Time:

Total Sampling Time:

Project No.:

Test Date:

Export all Sheets to

343 50.431 50.368 0.15 0.15 1.81 84 -0.91 1.25 83 -2.90 84 0.050 100 100 0.4 0.0 200 78 76 78 74 78 -0.024 1.71 0.020

344 50.579 50.515 0.15 0.15 1.82 84 -1.01 1.26 83 -2.90 83 0.050 100 100 0.4 0.0 201 78 76 78 74 78 -0.024 3.02 0.000

345 50.727 50.662 0.15 0.15 1.81 84 -1.01 1.27 83 -2.90 84 0.050 100 100 0.4 0.0 201 78 76 78 74 78 -0.024 1.95 0.010

346 50.875 50.809 0.15 0.15 1.82 84 -0.67 1.27 83 -2.90 83 0.050 100 100 0.3 0.0 200 78 76 78 74 78 -0.024 1.12 0.050

347 51.023 50.956 0.15 0.15 1.80 84 -0.61 1.27 83 -3.20 83 0.050 100 100 0.3 0.0 200 78 75 78 74 78 -0.025 2.03 0.000

348 51.170 51.104 0.15 0.15 1.83 84 -0.76 1.26 83 -3.20 83 0.050 99 100 0.3 0.0 200 78 75 78 74 78 -0.025 2.47 0.000

349 51.318 51.251 0.15 0.15 1.82 84 -1.07 1.26 83 -3.10 83 0.050 100 100 0.2 0.0 199 78 75 78 74 78 -0.024 1.46 0.020

350 51.466 51.398 0.15 0.15 1.82 84 -0.88 1.26 83 -3.00 83 0.050 100 100 0.2 0.0 199 78 75 78 74 77 -0.025 1.90 0.000

351 51.613 51.546 0.15 0.15 1.82 84 -0.92 1.26 83 -3.20 83 0.050 99 100 0.2 0.0 199 78 75 78 74 77 -0.025 2.30 0.000

352 51.762 51.692 0.15 0.15 1.81 84 -0.88 1.27 83 -3.20 83 0.050 101 99 0.2 0.0 198 78 75 78 74 78 -0.024 1.56 0.010

353 51.910 51.840 0.15 0.15 1.82 84 -0.84 1.26 83 -3.20 83 0.050 100 100 0.1 0.0 198 78 75 78 73 78 -0.023 1.96 0.010

354 52.058 51.987 0.15 0.15 1.83 84 -1.06 1.26 83 -3.00 83 0.050 100 100 0.1 0.0 199 78 75 78 73 78 -0.024 2.64 0.000

355 52.205 52.135 0.15 0.15 1.81 84 -0.99 1.26 83 -3.00 83 0.050 99 100 0.1 0.0 198 78 75 78 73 78 -0.024 2.10 0.000

356 52.353 52.281 0.15 0.15 1.80 84 -0.95 1.25 83 -3.10 83 0.050 100 99 0.1 0.0 198 78 75 78 73 78 -0.024 1.25 0.050

357 52.501 52.429 0.15 0.15 1.81 84 -0.65 1.25 83 -3.20 83 0.050 100 100 0.1 0.0 199 78 75 78 73 78 -0.025 2.93 0.000

358 52.648 52.575 0.15 0.15 1.80 84 -0.63 1.26 83 -3.20 83 0.050 99 99 0.0 0.0 199 78 75 78 73 78 -0.025 2.36 0.000

359 52.796 52.722 0.15 0.15 1.80 84 -0.84 1.26 83 -3.20 83 0.050 100 100 0.0 0.0 199 78 75 78 73 78 -0.025 1.28 0.040

360 52.944 52.870 0.15 0.15 1.80 84 -1.07 1.26 83 -3.10 83 0.050 100 100 0.0 0.0 199 78 74 79 73 77 -0.024 2.03 0.010

Avg/Tot 52.944 52.870 0.15 0.15 1.81 80 -0.86 1.26 80 -3.19 82 0.05 100 100 243 79 73 79 71 77 -0.032 3.70 0.056

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Data EntryPage 26 of 68

Page 27: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Page 27 of 68

Page 28: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Page 28 of 68

Page 29: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E

OMNI-Test Laboratories, Inc.

2.2 - Sample Analysis & Tares

Analysis Worksheets Tared Filter, Probe, and O-Ring Data

Pellet Fuel Label Pellet Fuel Analysis Report

Page 29 of 68

Page 30: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Page 30 of 68

Page 31: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc

Pellet Heater Lab Data - ASTM E2779 / ASTM E2515

Manufacturer: Travis Equipment Numbers:

Model: AGP PS

Tracking No.: 2308

Project No.: 0028PS108E

Run #: 1 Technician Signature:

Date: 8/29/18

TRAIN 1 (First Hour emissions)

Sample Component Reagent Filter, Probe Mass Readings

or Seal # Tare, mg Final, mg Particulate, mg

A. Front filter catch Filter D309 110.8 118.2 7.4

B. Rear filter catch Filter 0.0

C. Probe catch* Probe 0.0

D. Filter seals catch* Seals 0.0

1st

hour Sub-Total, mg: 7.4

TRAIN 1 (Remainder of Test)

Sample Component Reagent Filter, Probe Mass Readings

or Seal # Tare, mg Final, mg Particulate, mg

A. Front filter catch Filter D310 111.1 113.3 2.2

B. Rear filter catch Filter D311 111.7 111.8 0.1

C. Probe catch* Probe 28 114750.8 114750.8 0.0

D. Filter seals catch* Seals R634 3340.3 3340.3 0.0

Remainder Sub-Total, mg: 2.3

Train 1 Aggregate, mg: 9.7

TRAIN 2

Sample Component Reagent Filter, Probe Mass Readings

or Seal # Tare, mg Final, mg Particulate, mg

A. Front filter catch Filter D312 112.0 120.7 8.7

B. Rear filter catch Filter D313 110.5 110.8 0.3

C. Probe catch* Probe 21.0 114392.2 114392.8 0.6

D. Filter seals catch* Seals R635 3321.6 3321.5 0.0

Train 2 Aggregate, mg: 9.6

AMBIENT

Sample Component Reagent Filter, Probe Mass Readings

or Seal # Tare, mg Final, mg Particulate, mg

A. Front filter catch* Filter 0.0

Ambient Aggregate, mg: 0.0

*Particulate catch that results in a negative number, is assumed to be zero for probes and seals, negative numbers for filters are assumed to be

included in O-ring seal weights.

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Gravimetric Analysis

Page 31 of 68

Page 32: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Page 32 of 68

Page 33: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Page 33 of 68

Page 34: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Page 34 of 68

Page 35: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Twin Ports Testing, Inc.

1301 North 3rd Street

Superior, WI 54880

p: 715-392-7114

p: 800-373-2562

f: 715-392-7163www.twinportstesting.com

Report No: USR:W218-0827-01

Issue No: 1

Client: TRAVIS IND Signed:

12521 Harbour Reach Drive

Mukilteo, WA 98275

Attention: Russ McBrien

PO No: Date of Issue:

THIS DOCUMENT SHALL NOT BE REPRODUCED EXCEPT IN FULL

Sample Details

Sample Log No: Sample Date:

Sample Designation: Sample Time:

Sample Recognized As: Arrival Date:

Test Results

MOISTURE AS

METHOD UNITS FREE RECEIVED

Moisture Total ASTM E871 wt. % 3.85

Ash ASTM D1102 wt. % 0.18 0.17

Volatile Matter ASTM D3175 wt. %

Fixed Carbon by Difference ASTM D3172 wt. %

Sulfur ASTM D4239 wt. % 0.008 0.008

SO₂ Calculated lb/mmbtu 0.019

Net Cal. Value at Const. Pressure ISO 1928 GJ/tonne 18.87 18.05

Net Cal. Value at Const. Pressure ISO 1928 J/g 18868 18047

Gross Cal. Value at Const. Vol. ASTM E711 J/g 20181 19403

Gross Cal. Value at Const. Vol. ASTM E711 Btu/lb 8677 8342

Carbon ASTM D5373 wt. % 50.48 48.53

Hydrogen* ASTM D5373 wt. % 6.03 5.80

Nitrogen ASTM D5373 wt. % < 0.20 < 0.19

Oxygen* ASTM D3176 wt. % > 43.10 > 41.44

*Note: As received values do not include hydrogen and oxygen in the total moisture.

Chlorine ASTM D6721 mg/kg

Fluorine ASTM D3761 mg/kg

Mercury ASTM D6722 mg/kg

Bulk Density ASTM E873 lbs/ft3

Fines (Less than 1/8") TPT CH-P-06 wt.%

Durability Index Kansas State PDI

Sample Above 1.50" TPT CH-P-06 wt.%

Maximum Length (Single Pellet) TPT CH-P-06 inch

Diameter, Range TPT CH-P-05 inch to

Diameter, Average TPT CH-P-05 inch

Stated Bag Weight TPT CH-P-01 lbs

Actual Bag Weight TPT CH-P-01 lbs

Comments

Analytical Test Report

Katy Jahr

Chemistry Lab Supervisor

9/7/2018

W218-0827-01

Pellet Sample

Wood Pellets 8/30/2018

Page 35 of 68

Page 36: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Page 36 of 68

Page 37: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E

OMNI-Test Laboratories, Inc.

Section 3 Laboratory Quality Assurance

3.1 - Quality Assurance/Quality Control 3.2 - Calibration Data 3.3 - Example Calculations

Page 37 of 68

Page 38: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E

OMNI-Test Laboratories, Inc.

3.1 - Quality Assurance/Quality Control

OMNI follows the guidelines of ISO/IEC 17025, “General Requirements for the Competence of Testing and Calibration Laboratories,” and the quality assurance/quality control (QA/QC) procedures found in OMNI’s Quality Assurance Manual. OMNI’s scope of accreditation includes, but is not limited to, the following:

• ANSI (American National Standards Institute) for certification of product to safety standards.

• To perform product safety testing by the International Accreditation Service, Inc. (formerly ICBO ES) under accreditation as a testing laboratory designated TL-130.

• To perform product safety testing as a “Certification Organization” by the Standards Council of Canada (SCC).

• Serving as a testing laboratory for the certification of wood heaters by the U.S. Environmental Protection Agency.

This report is issued within the scope of OMNI’s accreditation. Accreditation certificates are available upon request. The manufacturing facilities and quality control system for the production of the AGP PS at Travis Industries were evaluated to determine if sufficient to maintain conformance with OMNI’s requirements for product certification. OMNI has concluded that the manufacturing facilities, processes, and quality control system are adequate to produce the appliance congruous with the standards and model codes to which it was evaluated. This report shall not be reproduced, except in full, without the written approval of OMNI-Test Laboratories, Inc.

Page 38 of 68

Page 39: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E

OMNI-Test Laboratories, Inc.

3.2 - Calibration Data

Equipment for ASTM E2515, ASTM E2779, & EPA Method 28R

ID # Lab Name/Purpose Log Name Attachment Type

132 10 lb Weight Weight Standard, 10 lb. Calibration Certificate

283A Audit Weights Troemner 21pc Msas Set Calibration Certificate

335 Sample Box / Dry Gas

Meter Apex Automated Emissions

Sampling Box Calibration Log

336 Sample Box / Dry Gas

Meter Apex Automated Emissions

Sampling Box Calibration Log

410 Microtector Dwyer Microtector Calibration Certificate

420 Combustion Gas

Analyzer CAI Gas Analyzer See Run Sheet

559 Vaneometer Dwyer Vaneometer Equipment Record

592 Thermohygrometer Omega Digital

Thermohygrometer Calibration Log

637 Milligram Balance Analytical Balance - Mettler -

Toledo Calibration Certificate

650 Barometer/Hygrometer Digital Barometer Calibration Certificate

Page 39 of 68

Page 40: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

159 of 235

Page 40 of 68

Page 41: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

163 of 235

Page 41 of 68

Page 42: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc.

Thermal Metering System Calibration

Y Factor

Previous Calibration Comparision

Manufacturer: Apex Date 1/16/2018

Acceptable

Deviation (5%) Deviation

Model: XC-60-EP y Factor 0.997 0.04985 0.014

Serial Number: 0702003 Acceptance Acceptable

OMNI Tracking No.: OMNI-00371

Calibrated Orifice: Current Calibration

Acceptable y Deviation 0.020

Average Gas Meter y

Factor

Orifice

Meter

dH@ Maximum y Deviation 0.007

0.983 N/A Acceptable dH@ Deviation N/A

Calibration Date: 07/16/18 Maximum dH@ Deviation N/A

Calibrated by: B. Davis Acceptance Acceptable

Calibration Frequency: 6 months

Next Calibration Due: 1/16/2019

Instrument Range: 1.000 cfm

Standard Temp.: 68 oF Reference Standard *

Standard Press.: 29.92 "Hg Standard Model Standard Test Meter

Barometric Press., Pb: 30.08 "Hg Calibrator S/N OMNI-00001

Signature/Date: 7/16/2018 Calib. Date 30-Oct-17

Calib. Value 0.9977 y factor (ref)

Calibration Parameters Run 1 Run 2 Run 3

Reference Meter Pressure ("H2O), Pr 0.00 0.00 0.00

DGM Pressure ("H2O), Pd 3.00 1.70 1.00

Initial Reference Meter 534.8 524 529.6

Final Reference Meter 540.302 529.514 534.7

Initial DGM 0 0 0

Final DGM 5.505 5.593 5.22

Temp. Ref. Meter (°F), Tr 85.0 82.0 81.0

Temperature DGM (°F), Td 85.0 83.0 84.0

Time (min) 28.8 35.5 47.8

Net Volume Ref. Meter, Vr 5.502 5.514 5.100

Net Volume DGM, Vd 5.505 5.593 5.22

Gas Meter y Factor = 0.990 0.981 0.978

Gas Meter y Factor Deviation (from avg.) 0.007 0.002 0.005

Orifice dH@ N/A N/A N/A

Orifice dH@ Deviation (from avg.) N/A N/A N/A

where:

1. Deviation = |Average value for all runs - current run value|

** 2. y = [Vr x (y factor (ref)) x (Pb + (Pr/ 13.6)) x (Td + 460) ]/ [Vd x (Pb + (Pd / 13.6)) x (Tr + 460)]

** 3. dH@ = 0.0317 x Pd / (Pb (Td + 460)) x [ (Tr + 460) x time) / Vr ]^2

* Reference calibration is traceable to NIST through NIST Test # 40674, Kimble ASTM E1272, or NIST traceable laboratory

** Equations come from EPA Method 5

The uncertainty of measurement is ±0.14 ft3/min. This is based on the reference standard having a TAR (Test Accuracy Ratio) of at least 4:1.

Control No. C-SSB-0005, Effective Date: 7/7/2011 164 of 235

Page 42 of 68

Page 43: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

7/20/18

165 of 235

Page 43 of 68

Page 44: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc.

Control No. C-SFAK-0001, Effective date 12/2/2015 Page 1 of 1

DIFFERENTIAL PRESSURE GAUGE CALIBRATION DATA SHEET

Instrument to be calibrated: Pressure Transducer Maximum Range: 0-2” WC ID Number: OMNI-00371 Calibration Instrument: Digital Manometer ID Number: OMNI-00395 Date: 7/16/18 By: B. Davis This form is to be used only in conjunction with Standard Procedure C-SPC.

*Acceptable tolerance is 4%. The uncertainty of measurement is ±0.4” WC. This is based on the reference standard having a TAR (Test Accuracy Ratio) of at least 4:1.

Technician signature: Date: 7/16/18 Reviewed by: Date:

Range of Calibration Point

(″WC)

Digital Manometer

Input (″WC)

Pressure Gauge Response

(″WC)

Difference (Input -

Response)

% Error of Full Span*

0-20% Max. Range 0 - 0.4

0.231 0.223 0.008 0.4

20-40% Max. Range 0.4 - 0.8

0.571 0.564 0.007 0.35

40-60% Max. Range 0.8 – 1.2

0.991 0.985 0.006 0.3

60-80% Max. Range 1.2 – 1.6

1.228 1.219 0.009 0.45

80-100% Max. Range 1.6 – 2.0

1.840 1.827 0.013 0.65

7/20/2018

166 of 235

Page 44 of 68

Page 45: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc.

Thermal Metering System Calibration

Y Factor

Previous Calibration Comparision

Manufacturer: Apex Date 1/17/2018

Acceptable

Deviation (5%) Deviation

Model: XC-60-EP y Factor 0.981 0.04905 0.007

Serial Number: 0702004 Acceptance Acceptable

OMNI Tracking No.: OMNI-00372

Calibrated Orifice: Current Calibration

Acceptable y Deviation 0.020

Average Gas Meter y

Factor

Orifice

Meter

dH@ Maximum y Deviation 0.008

0.974 N/A Acceptable dH@ Deviation N/A

Calibration Date: 07/16/18 Maximum dH@ Deviation N/A

Calibrated by: B. Davis Acceptance Acceptable

Calibration Frequency: 6 months

Next Calibration Due: 1/16/2019

Instrument Range: 1.000 cfm

Standard Temp.: 68 oF Reference Standard *

Standard Press.: 29.92 "Hg Standard Model Standard Test Meter

Barometric Press., Pb: 30.08 "Hg Calibrator S/N OMNI-00001

Signature/Date: 7/16/2018 Calib. Date 27-Oct-16

Calib. Value 0.9977 y factor (ref)

Calibration Parameters Run 1 Run 2 Run 3

Reference Meter Pressure ("H2O), Pr 0.00 0.00 0.00

DGM Pressure ("H2O), Pd 3.00 1.30 0.80

Initial Reference Meter 540.8 547.1 627.2

Final Reference Meter 547.004 552.102 633.4

Initial DGM 0 0 0

Final DGM 6.244 5.121 6.353

Temp. Ref. Meter (°F), Tr 86.0 88.0 88.0

Temperature DGM (°F), Td 85.0 87.0 87.0

Time (min) 27.5 34.5 56.5

Net Volume Ref. Meter, Vr 6.204 5.002 6.200

Net Volume DGM, Vd 6.244 5.121 6.353

Gas Meter y Factor = 0.982 0.970 0.970

Gas Meter y Factor Deviation (from avg.) 0.008 0.004 0.004

Orifice dH@ N/A N/A N/A

Orifice dH@ Deviation (from avg.) N/A N/A N/A

where:

1. Deviation = |Average value for all runs - current run value|

** 2. y = [Vr x (y factor (ref)) x (Pb + (Pr/ 13.6)) x (Td + 460) ]/ [Vd x (Pb + (Pd / 13.6)) x (Tr + 460)]

** 3. dH@ = 0.0317 x Pd / (Pb (Td + 460)) x [ (Tr + 460) x time) / Vr ]^2

* Reference calibration is traceable to NIST through NIST Test # 40674, Kimble ASTM E1272, or NIST traceable laboratory

** Equations come from EPA Method 5

The uncertainty of measurement is ±0.14 ft3/min. This is based on the reference standard having a TAR (Test Accuracy Ratio) of at least 4:1.

Control No. C-SSB-0005, Effective Date: 7/7/2011 167 of 235

Page 45 of 68

Page 46: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

7/20/18

168 of 235

Page 46 of 68

Page 47: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc.

Control No. C-SFAK-0001, Effective date 12/2/2015 Page 1 of 1

DIFFERENTIAL PRESSURE GAUGE CALIBRATION DATA SHEET

Instrument to be calibrated: Pressure Transducer Maximum Range: 0-2” WC ID Number: OMNI-00372 Calibration Instrument: Digital Manometer ID Number: OMNI-00395 Date: 7/16/18 By: B. Davis This form is to be used only in conjunction with Standard Procedure C-SPC.

*Acceptable tolerance is 4%. The uncertainty of measurement is ±0.4” WC. This is based on the reference standard having a TAR (Test Accuracy Ratio) of at least 4:1.

Technician signature: Date: 7/16/18 Reviewed by: Date:

Range of Calibration Point

(″WC)

Digital Manometer

Input (″WC)

Pressure Gauge Response

(″WC)

Difference (Input -

Response)

% Error of Full Span*

0-20% Max. Range 0 - 0.4

0.037 0.042 0.005 0.25

20-40% Max. Range 0.4 - 0.8

0.512 0.509 0.003 0.15

40-60% Max. Range 0.8 – 1.2

1.169 1.164 0.005 0.25

60-80% Max. Range 1.2 – 1.6

1.540 1.533 0.007 0.35

80-100% Max. Range 1.6 – 2.0

1.772 1.776 0.004 0.20

7/20/2018

169 of 235

Page 47 of 68

Page 48: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

170 of 235

Page 48 of 68

Page 49: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

171 of 235

Page 49 of 68

Page 50: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

172 of 235

Page 50 of 68

Page 51: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Page 51 of 68

Page 52: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

175 of 235

Page 52 of 68

Page 53: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

YES X NO

1) Complete Calibration documentation

Part #

OMNI Track #

Equipment Name/Description

Equipment S/N:

Comments

Status

Reference Standard:

Location of Equipment:

Do the following:

Date of Next Calibration

Date of Last Calibration

Calibration Period (Months)

Type of Calibration

Calibration Vendor

Portable gas cart.

Active, calibrate prior to use.

N5F0112

N/A

N/A

N/A

Calibrate Prior to use.

OMNI in house

CAI ZRE-4 Gas Analyzer

OMNI-00594

CO2, O2, and dual range CO gas analyzer.

ZRE-4

(Check 'X' for answer)

1) Complete Calibration documentation

2) Complete top half of this form

3) Attach appropriate calibration forms and save in following location

\\omni-serv\Test Equipment\Equipment\OMNI-XXXXX - Equipment Name

4) Repopulate database with updated information

5) Print, laminate and adhere calibration tag to equipment

Do the following:

Verify before useOMNI-00594Gas Analyzer

Verify before useOMNI-00594Gas Analyzer

173 of 235

Page 53 of 68

Page 54: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E

OMNI-Test Laboratories, Inc.

3.3 - Example Calculations

Page 54 of 68

Page 55: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc.

Equations and Sample Calculations – ASTM E2779 & E2515

Manufacturer:

Model:

Run:

Category:

MBdb – Weight of test fuel burned during test run, dry basis, kg

MBSidb – Weight of test fuel burned during test run segment i , dry basis, kg

BR – Average dry burn rate over full integrated test run, kg/hr

BRSi – Average dry burn rate over test run segment i , kg/hr

Vs – Average gas velocity in the dilution tunnel, ft/sec

Qsd – Average gas flow rate in dilution tunnel, dscf/hr

Vm(std) – Volume of Gas Sampled Corrected to Dry Standard Conditions, dscf

mn – Total Particulate Matter Collected, mg

Cs - Concentration of particulate matter in tunnel gas, dry basis, corrected to standard conditions, g/dscf

ET – Total Particulate Emissions, g

PR - Proportional Rate Variation

PMR – Average particulate emissions for full integrated test run, g/hr

PMF – Average particulate emission factor for full integrated test run, g/dry kg of fuel burned

Travis

AGP PS

1

Integrated

are provided for each equation. The raw data and printout results from a sample run are also provided for

Equations used to calculate the parameters listed below are described in this appendix. Sample calculations

comparison to the sample calculations.

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Example Calculations

Page 55 of 68

Page 56: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc.

Equations and Sample Calculations – ASTM E2779 & E2515MBdb – Weight of test fuel burned during test run, dry basis, kg

ASTM E2779 equation (1)

MBdb = (MSwb - MEwb)(100/(100 + FM))

Where,

FM = average fuel moisture of test fuel, % dry basis

MSwb = weight of test fuel in hopper at start of test run, wet basis, kg

MEwb = weight of test fuel in hopper at end of test run, wet basis, kg

Sample Calculation:

3.85 %

MSwb = 14.9 lbs

MEwb = 0.0 lbs

0.4536 = Converstion factor from lbs to kg

MBdb = [( 14.9 x 0.4536) - ( 0.0 x 0.4536)] (100/(100 + 3.85 )

MBdb = 6.51 kg

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Example Calculations

Page 56 of 68

Page 57: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc.

Equations and Sample Calculations – ASTM E2779 & E2515MBSidb – Weight of test fuel burned during test run segment i , dry basis, kg

ASTM E2779 equation (2)

MBSidb = (MSSiwb - MESiwb)(100/(100 + FM))

Where,

MSSiwb = weight of test fuel in hopper at start of test run segment i , wet basis, kg

MESiwb = weight of test fuel in hopper at end of test run segment i , wet basis, kg

Sample Calculation (from medium burn rate segment):

FM = 3.85 %

MSSiwb = 9.7 lbs

MESiwb = 4.6 lbs

0.4536 = Converstion factor from lbs to kg

MBSidb = [( 9.7 x 0.4536) - ( 4.6 x 0.4536)] (100/(100 + 4 )

MBSidb = 2.2 kg

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Example Calculations

Page 57 of 68

Page 58: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc.

Equations and Sample Calculations – ASTM E2779 & E2515

BR – Average dry burn rate over full integrated test run, kg/hr

ASTM E2779 equation (3)

60 MBdb

θ

Where,

θ = Total length of full intergrated test run, min

Sample Calculation:

MBdb = 6.51 kg

θ = 360 min

60 x 6.51

BR = 1.08

BR = 360

kg/hr

BR =

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Example Calculations

Page 58 of 68

Page 59: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc.

Equations and Sample Calculations – ASTM E2779 & E2515BRSi – Average dry burn rate over test run segment i , kg/hr

ASTM E2779 equation (4)

60 MBSidb

θSi

Where,

θSi = Total length of test run segment i , min

Sample Calculation (from medium burn rate segment):

MBSidb = 2.23 kg

θ = 120 min

60 x 2.23

BR = 1.11 kg/hr

BRSi =

BR = 120

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Example Calculations

Page 59 of 68

Page 60: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc.

Equations and Sample Calculations – ASTM E2779 & E2515Vs – Average gas velocity in the dilution tunnel, ft/sec

ASTM E2515 equations (9)

Where:

vscent = Dilution tunnel velocity calculated after the multi-point pitot traverse at the center, ft/sec

vstrav = Dilution tunnel velocity calculated after the multi-point pitot traverse, ft/sec

kp = Pitot tube constant, 85.49

Cp = Pitot tube coefficient: 0.99, unitless

ΔP* = Velocity pressure in the dilution tunnel, in H2O

Ts = Absolute average gas temperature in the dilution tunnel, °R; (°R = °F + 460)

Ps = Absolute average gas static pressure in diltuion tunnel, = Pbar + Pg , in Hg

Pbar = Barometric pressure at test site, in. Hg

Pg = Static pressure of tunnel, in. H20; (in Hg = in H20/13.6)

Ms = **The dilution tunnel wet molecular weight; Ms = 28.78 assuming a dry weight of 29 lb/lb-mole

Sample calculation:

14.23

15.17

82.4 + 1/2

Vs = 0.938 x 85.49 x 0.99 x 0.224 x -0.15

13.6

Vs = 14.22 ft/s

*The ASTM test standard mistakenly has the square root of the average delta p instead of

the average of the square root of delta p. The current EPA Method 2 is also incorrect. This

was verified by Mike Toney at EPA.

**The ASTM test standard mistakenly identifies Ms as the dry molecular weight. It should be

the wet molecular weight as indicated in EPA Method 2.

)460

28.7829.37 +((

Fp = Adjustment factor for center of tunnel pitot tube placement, Fp =

Fp = = 0.938

Vstrav

Vscent

, ASTM E2515 Equation (1)

) x

( )ss

s

avgPppsMP

TPCKFV

=

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Example Calculations

Page 60 of 68

Page 61: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc.

Equations and Sample Calculations – ASTM E2779 & E2515Qsd – Average gas flow rate in dilution tunnel, dscf/hr

ASTM E2515 equation (3)

Where:

3600 = Conversion from seconds to hours (ASTM method uses 60 to convert in minutes)

Bws = Water vapor in gas stream, proportion by volume; assume 2%

A = Cross sectional area of dilution tunnel, ft2

Tstd = Standard absolute temperature, 528 °R

Ps = Absolute average gas static pressure in diltuion tunnel, = Pbar + Pg , in Hg

Ts = Absolute average gas temperature in the dilution tunnel, °R; (°R = °F + 460)

Pstd = Standard absolute pressure, 29.92 in Hg

Sample calculation: -0.15

13.6

82.4 + 460

Qsd = 9409.7 dscf/hr

x528

x29.92

14.22 x 0.1963

29.37 +

Qsd = 3600 x (1 - 0.02) x

std

s

s

std

swssdP

P

T

TAvBQ −= )1(3600

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Example Calculations

Page 61 of 68

Page 62: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc.

Equations and Sample Calculations – ASTM E2779 & E2515Vm(std) – Volume of Gas Sampled Corrected to Dry Standard Conditions, dscf

ASTM E2515 equation (6)

Where:

K1 = 17.64 °R/in. Hg

Conversion from seconds to hours (ASTM method uses 60 to convert in minutes) Vm = Volume of gas sample measured at the dry gas meter, dcf

Y = Dry gas meter calibration factor, dimensionless

Pbar = Barometric pressure at the testing site, in. Hg

∆H = Average pressure differential across the orifice meter, in. H2O

Tm = Absolute average dry gas meter temperature, °R

Sample Calculation:

Using equation for Train 1: 1.81

Vm(std) = 17.64 x 52.944 x 0.997 x 13.6

( 79.7 + 460 )

Vm(std) = 50.893 dscf

Using equation for Train 2: 1.26

Vm(std) = 17.64 x 52.870 x 0.981 x 13.6

( 79.5 + 460 )

Vm(std) = 49.955 dscf

Using equation for ambient train: 0.00

Vm(std) = 17.64 x 0.00 x 0 x 13.6

( 76.7 + 460 )

Vm(std) = 0.000 dscf

( )

( 29.37

29.37 +

(

)+

29.37 + )

m

bar

mstdmT

HP

YVKV

+

=6.13

1)(

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Example Calculations

Page 62 of 68

Page 63: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc.

Equations and Sample Calculations – ASTM E2779 & E2515mn – Total Particulate Matter Collected, mg

ASTM E2515 Equation (12)

Where:

mp = mass of particulate matter from probe, mg

mf = mass of particulate matter from filters, mg

mg = mass of particulate matter from filter seals, mg

Sample Calculation:

Using equation for Train 1 (first hour):

mn = 0.0 + 7.4 + 0.0

mn = 7.4 mg

Using equation for Train 1 (remainder):

mn = 0.0 + 2.3 + 0.0

mn = 2.3 mg

Train 1 Aggregate = 9.7 mg

Using equation for Train 2:

mn = 0.6 + 9.0 + 0.0

mn = 9.6 mg

gfpn mmmm ++=

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Example Calculations

Page 63 of 68

Page 64: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc.

Equations and Sample Calculations – ASTM E2779 & E2515Cs - Concentration of particulate matter in tunnel gas, dry basis, corrected to standard conditions, g/dscf

ASTM E2515 equation (13)

Where:

K2 = Constant, 0.001 g/mg

mn = Total mass of particulate matter collected in the sampling train, mg

Vm(std) = Volume of gas sampled corrected to dry standard conditions, dscf

Sample calculation:

For Train 1:

9.7

50.89

Cs = 1.91E-04 g/dscf

For Train 2

9.6

49.95

Cs = 1.92E-04 g/dscf

For Ambient Train

0.0

0.00

Cr = 0.000000 g/dscf

Cs = 0.001 x

Cs = 0.001 x

Cr = 0.001 x

)(

2

stdm

ns

V

mKC =

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Example Calculations

Page 64 of 68

Page 65: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc.

Equations and Sample Calculations – ASTM E2779 & E2515ET – Total Particulate Emissions, g

ASTM E2515 equation (15)

Where:

Cs = Concentration of particulate matter in tunnel gas, g/dscf

Cr = Concentration particulate matter room air, g/dscf

Qstd = Average dilution tunnel gas flow rate, dscf/hr

θ = Total time of test run, minutes

Sample calculation:

For Train 1

ET = ( 0.000191 - 0.000000 ) x 9409.7 x 360 /60

ET = 10.76 g

For Train 2

ET = ( 0.000192 - 0.000000 ) x 9409.7 x 360 /60

ET = 10.85 g

Average

E = 10.81 g

Total emission values shall not differ by more than 7.5% from the total average emissions

7.5% of the average = 0.81

Train 1 difference = 0.04

Train 2 difference = 0.04

( ) −= stdrsT QccE

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Example Calculations

Page 65 of 68

Page 66: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc.

Equations and Sample Calculations – ASTM E2779 & E2515

PR - Proportional Rate Variation

ASTM E2515 equation (16)

Where:

θ = Total sampling time, min

θi = Length of recording interval, min

Vmi = Volume of gas sample measured by the dry gas meter during the “ith”

time interval, dcf

Vm = Volume of gas sample as measured by dry gas meter, dcf

Vsi = Average gas velocity in the dilution tunnel during the "ith" time interval, ft/sec

Vs = Average gas velocity in the dilution tunnel, ft/sec

Tmi = Absolute average dry gas meter temperature during the "ith" time interval, oR

Tm = Absolute average dry gas meter temperature, oR

Tsi = Absolute average gas temperature in the dilution tunnel during the "ith" time interval, oR

Ts = Absolute average gas temperature in the dilution tunnel, oR

Sample calculation (for the first 1 minute interval of Train 1):

360 x 0.136 x 14.22 x ( 86.0 + 460 ) x ( 79.7 + 460 )

1 x 52.944 x 14.27 x ( 82.4 + 460 ) x ( 78.0 + 460 )

PR = 93 %

x 100)(PR =

100

=

smisimi

simsmi

TTVV

TTVVPR

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Example Calculations

Page 66 of 68

Page 67: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc.

Equations and Sample Calculations – ASTM E2779 & E2515PMR – Average particulate emissions for full integrated test run, g/hr

ASTM E2779 equation (5)

PMR = 60 (ET/θ)

Where,

ET = Tota particulate emissions, grams

θ = Total length of full intergrated test run, min

Sample Calculation:

ET (Dual train average) = 10.81 g

θ = 360 min

PMR = 60 x ( 10.81 / 360 )

PMR = 1.80 g/hr

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Example Calculations

Page 67 of 68

Page 68: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

OMNI-Test Laboratories, Inc.

Equations and Sample Calculations – ASTM E2779 & E2515PMF – Average particulate emission factor for full integrated test run, g/dry kg of fuel burned

ASTM E2779 equation (6)

PMF = ET/MBdb

Where,

ET = Tota particulate emissions, grams

MBdb = Weight of test fuel burned during test run, dry basis, kg

Sample Calculation:

ET (Dual train average) = 10.81 g

MBdb = 6.51 kg

PMF = 10.81 / 6.51 )

PMF = 1.66 g/kg

Control No. P-SFDK-0004, Effective Date 9/26/2018 File - P-SFDK-0004, Tab - Example Calculations

Page 68 of 68

Page 69: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E

OMNI-Test Laboratories, Inc.

Appendix A – Labeling & Owner’s Manual

Page 69 of 68

Page 70: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

WARNING - DO NOT REMOVE OR COVER THIS LABEL

Report No. 100517995-001Control No. 4000515

MODEL: AGP PSListed Pelletized Solid Fuel Burning Appliance

Also for use in mobile homesCertified for US and Canada

SERIAL NO:

Conforms to ASTM E1509-12, Room Heater Pellet Burning Type (UM) 84 HUD; Certified to ULC S627Electrical Rating: 120 VAC, 60 Hz, 3 Amp: Start 3 Amps, Run 2.2 Amps with blower on HighMaximum Input Rating: 5.0 lbs/hrThis pellet fired appliance has been tested and listed for use in manufactured (mobile) homes in accordance with OAR 814-23-900 through 814-23-909.WARNING - FOR MANUFACTURED HOMES: Must utilize outside combustion air inlet (part #99200136) or equivalent. Structural integrity of the manufactured home floor, ceiling and walls must be maintained.Install and use only in accordance with the manufacturer’s installation and operating instructions. Contact local building or fire officials about restrictions and installation inspection in your area. Use only 3 in. / 77 mm or 4 in. / 102 mm diameter listed type “L” or “PL” venting system. See manufacturer’s installation instructions and local codes for precautions required for passing chimney through a combustible wall or ceiling. Do not connect this unit to a chimney flue serving another appliance. Inspect and clean exhaust venting system frequently in accordance with manufacturer’s instructions.May be installed in a sleeping room with use of outside combustion air inlet (Part #99200136) or equivalent.This pellet heater needs periodic inspection and repair for proper operation. Consult the owner’s manual for further information. It is against federal regulations to operate this wood heater in a manner inconsistent with the operating instructions in the owner’s manual.

For use with 1/4 in. / 6 mm to 5/16 in. / 7 mm diameter pelletized wood fuels only.Replace glass only with 5 mm ceramic glass available from your dealer.DANGER: Risk of electrical shock. Disconnect power supply before servicing. Route power cord away from unit. Do not route power cord beneath heater.Operate only with viewing door and ash removal tray tightly closed. Do not obstruct combustion air openings. The space beneath heater must not be obstructed. Keep all furnishings away from heater.

Minimum Clearance to Combustible Materials (Measured to Stove Top)

ABCD

SIDE WALLREAR WALLCORNERFLUE VENT

Interior VerticalFlue Installation

6 in. / 153 mm**

3 in. / 77 mm2 in. / 51 mm**

Horizontal Throughthe Wall Installation

6 in. / 153 mm3 in. / 77 mm3 in. / 77 mm

2 in. / 51 mm**

B

E

REAR WALLSI

DEW

ALL

SIDE

WAL

L

D

A A

F F

FLOOR PROTECTOR

CORNER

CORN

ER

C

C

Maximum alcove depth 48 in. / 1220 mm., minimum ceiling height 60 in. / 1524 mm., minimum alcove width 36-9/16 in. / 929 mm.Combustible floor must be protected by a non-combustible material underneath appliance, extending to the front (E) 6 in. / 153 mm. and to the sides (F) 0 in. / 0 mm.EXCEPTIONS: Non-combustible floor protection must extend beneath a vent tee when installed.** This dimension will vary depending on brand of listed type “L” vent. See manual for details.

12521 Harbour Reach DriveMukilteo, WA 98275

Manufactured by:

www.travisproducts.com

OMNI-Test Laboratories, Inc.Report No. 0028PS108E

U.S. ENVIRONMENTAL PROTECTION AGENCYCertified to comply with 2020 particulate emission standards using wood pellet fuel.

1.8 g/h, ASTM E2279-10, ASTM 2515-11, CSA B415.1-10

Made in U.S.A.

2018 2019 2020 Jan. Feb. Mar. Apr. May June July Aug. Sep. Oct. Nov. Dec.DATE OF MANUFACTURE:

1000

Page 71: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

AVERTISSEMENT - NE PAS ENLEVER OU COUVRIR CETTE ÉTIQUETTE

Rapport No. 100517995-001Contrôle No. 4000515

MODÈLE: AGP PSAppareil de combustion à combustible solide granulé

Aussi pour utilisation dans les maisons mobilesCertifié pour les États-Unis et le Canada 12521 Harbour Reach Drive

Mukilteo, WA 98275

Fabriqué par:

www.travisproducts.comConforme à ASTM E1509-04, Room Heater Pellet Burning Type (UM) 84 HUD; Certifié pour ULC S627Puissance électrique: 120 VAC, 60 Hz, 3 ampères: démarrage à 3 ampères, fonctionnement à 2,2 ampères avec ventilateur en hautVALEUR D'ENTRÉE MAXIMALE: 5,0 lb / hCet appareil à pellets a été testé et répertorié pour une utilisation dans les maisons (mobiles) fabriquées conformément aux OAR 814-23-900 à 814-23-909.AVERTISSEMENT - POUR LES MAISONS FABRIQUÉES: Doit utiliser une entrée d'air de combustion extérieure (pièce no. 99200136) ou équivalent. L'intégrité structurelle du plancher, du plafond et des murs de la maison doit être maintenue.Installez et utilisez uniquement conformément aux instructions d’installation et d’utilisation du fabricant. Contactez les responsables locaux du bâtiment ou du service des incendies pour connaître les restrictions et l'inspection de l'installation dans votre région. Utiliser uniquement un système de ventilation de type «L» ou «PL» de 3 po / 77 mm ou de 4 po / 102 mm de diamètre. Voir les instructions d’installation du fabricant et les codes locaux pour connaître les précautions à prendre pour faire passer la cheminée à travers un mur ou un plafond combustible. Ne connectez pas cet appareil à un conduit de cheminée desservant un autre appareil. Inspectez et nettoyez fréquemment le système d’échappe-ment conformément aux instructions du fabricant.Peut être installé dans une chambre à coucher avec une entrée d'air de combustion extérieure (pièce no. 99200136) ou équivalent.Ce radiateur à pellets doit être inspecté et réparé périodiquement pour assurer un fonctionnement correct. Consultez le manuel du propriétaire pour plus d’informations. Il est contraire à la réglementation fédérale d’utiliser ce poêle à bois d’une manière incompatible avec les instructions d’utilisation du manuel de l’utilisateur.

À utiliser uniquement avec des combustibles à base de bois de 1/4 po / 6 mm à 5/16 po / 7 mm de diamètre.Remplacez le verre uniquement avec du verre céramique de 5 mm disponible chez votre revendeur.DANGER: Risque de choc électrique. Débranchez l'alimentation électrique avant de procéder à l'entretien. Éloignez le cordon d'alimentation de l'appareil. Ne pas acheminer le cordon d'alimentation sous le chauffage.Ne faites fonctionner que lorsque la porte et le bac à cendres sont bien fermés. Ne pas obstruer les ouvertures d'air de combustion. L'espace sous le chauffage ne doit pas être obstrué. Gardez tous les meubles loin de l'appareil de chauffage.

DÉGAGEMENT MINIMUM PAR RAPPORT AUX MATÉRIAUX COMBUSTIBLES (MESURÉ SELON LE DESSUS DE LA CUISINIÈRE)

ABCD

MUR LATÉRALMUR ARRIÈRECOINCONDUIT D'ÉVACUATION

Intérieur verticalInstallation de fumée

6 po / 153 mm**

3 po / 77 mm2 po / 51 mm**

Traversée horizontalel'installation murale

6 po / 153 mm3 po / 77 mm3 po / 77 mm

2 po / 51 mm**

B

E

MUR ARRIÈRE

MUR

LATÉ

RAL

MUR

LATÉ

RALD

A A

F F

PROTECTEUR DE SOL

COIN

COIN

C

C

Profondeur alcôve maximale 48 po / 1220 mm, hauteur minimale du plafond 60 po / 1524 mm, largeur minimum de l’alcôve 36-9/16 po / 929 mmLe plancher combustible doit être protégé par un matériau incombustible situé sous l’appareil, jusqu’à l’avant (E) de 153 mm (6 po). et sur les côtés (F) 0 po / 0 mm.EXCEPTIONS: La protection de plancher non combustible doit s'étendre sous un évent si installé.** Cette dimension variera en fonction de la marque de l'évent de type «L» répertorié. Voir le manuel pour plus de détails.

OMNI-Test Laboratories, Inc.Rapport No. 0028PS108E

ETATS-UNIS AGENCE POUR LA PROTECTION DE L'ENVIRONNEMENTCertifié conforme aux normes d'émissions de particules de 2020 utilisant des granulés de bois.

1,8 g/h, ASTM E2279-10, ASTM 2515-11, CSA B415.1-10

Page 72: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

ꞏ AGP Pellet Stove ꞏ

• Horizontal or Vertical Vent

• Freestanding Stove

• Mobile Home Approved

• Class A Chimney Retrofit

• Hearth Stove into Existing Masonry Chimney , Masonry Fireplace, or Z.C. Fireplace

-- Please read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury, or even death.

-- Contact local building or fire officials about restrictions and installation inspection requirements in your area.

-- Save these instructions.

Tested and Listed by:

ASTM E1509-4 ULC-S627

Installer: After installation give this manual to the home-owner and explain operation of this stove.

Consumer: Retain this manual for future reference.

$10.00 Copyright 2018, T.I. Part # 100-01270 10/8/18

Travis Industries, Inc.

www.travisproducts.com

12521 Harbour Reach Drive SW

Mukilteo, WA 98275

Page 73: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

2 Introduction

© Travis Industries 10/8/18- 1270 AGP Stove

Introduction We welcome you as a new owner of an AGP pellet stove. In purchasing an AGP pellet stove you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics. The AGP pellet stove is one of the finest home heaters the world over. This manual will explain the installation, operation, and maintenance of this pellet-burning heater. Please familiarize yourself with this Owner's Manual before operating your heater and save the manual for future reference. Included are helpful hints and suggestions which will make the installation and operation of your new heater an easier and more enjoyable experience. We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your heater.

Important Information No other AGP pellet stove has the same serial number as yours. The serial number is on the safety label on the back of the appliance. This serial number will be needed in case you require service of any type. Model: AGP PS Serial Number: Purchase Date: Purchased From:

Register your warranty online at:

traviswarranty.com

Save Your Bill of Sale.

To receive full warranty coverage, you will need to show evidence of the date you purchased your heater. We suggest that you attach your Bill of Sale to this page so that you will have all the information you need in one place should the need for service or information occur.

Page 74: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Table of Contents 3

© Travis Industries 10/8/18- 1270 AGP Stove

Introduction .............................................................. 2 Important Information .............................................. 2 Heating Specifications ............................................. 7 Dimensions ............................................................... 7 Electrical Specifications .......................................... 7 Fuel ............................................................................ 7 Emissions ................................................................. 7 Efficiency .................................................................. 7 Before You Begin ..................................................... 8 Packing List .............................................................. 8 Items Required ......................................................... 8 Installation Options .................................................. 8 Planning the Installation .......................................... 9 Stove Placement ...................................................... 9 Floor Protection Requirements ............................... 9 Electrical Requirements .......................................... 9 Clearances .............................................................. 10 

Straight Installations ............................................ 10 Corner Installations ............................................. 10 

Venting the Pellet Stove ........................................ 11 Maximum Venting Distance ................................ 11 Pellet Vent Type .................................................. 12 Installing the Pellet Vent ..................................... 12 Pellet Vent Termination ....................................... 12 

Mobile Home Requirements .................................. 13 

Outside Air (Used for Combustion Use Part #99200136) .............................................................. 13 Alcove Installation Requirements ......................... 14 Restrictor Adjustment ........................................... 14 Installation Examples ............................................ 15 

Installation Example: Direct "Through-the-wall" Installation ........................................................... 15 Installation Example: Interior Vertical Installation 16 Installation Example: Class “A” Chimney Retrofit 17 Installation Example: Masonry Fireplace Hearth Stove ................................................................... 18 

Installation Example: Zero-Clearance (Metal) Fireplace Hearth Stove ....................................... 19 Installation Example: Freestanding Masonry Chimney .............................................................. 20 

Safety Notice .......................................................... 21 Location of Controls .............................................. 21 Loading Pellets ....................................................... 22 Starting the Heater for the First Time ................... 22 

Curing the Paint .................................................. 22 Manual Mode .......................................................... 23 

To Start ................................................................... 23 To Shut Down ......................................................... 23 To Adjust the Heat .................................................. 23 To Adjust Heat Output ............................................. 24 Auto-Fan ................................................................. 24 

TSTAT (Thermostat) Mode .................................... 25 To Start the Stove in TSTAT Mode ......................... 25 To Adjust the Heat Output ....................................... 25 To Shut Down ......................................................... 25 

Changing the TSTAT Program ............................ 26 How to Tell Which TSTAT Program You Are In ...... 26 Switching Between Program 1, 2, and 3 ................. 26 Thermostat Program 1 ............................................ 26 Thermostat Program 2 ............................................ 26 Thermostat Program 3 ............................................ 26 

Start-Up Sequence (Igniter) ................................... 27 Power Outages ....................................................... 27 

Manual Mode .......................................................... 27 TSTAT Mode ........................................................... 27 

Stove Maintenance ................................................. 28 Troubleshooting Table .......................................... 42 Replacement Parts ................................................. 42 

Door Parts ........................................................... 42 Wiring Diagram ....................................................... 43 Thermostat Installation (Optional) ........................ 44 Outside Air Kit ........................................................ 44 

Page 75: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

4 Safety Precautions

© Travis Industries 10/8/18- 1270 AGP Stove

HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING, AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. Educate all children of the danger of a high-temperature heater. Young children should be supervised when they are in the same room as the heater.

Contact your local building officials to obtain a permit and information on any installation restrictions or inspection requirements in your area. Notify your insurance company of this appliance as well.

Do not operate the heater if you smell smoke coming from the heater. Press the “STOP” button, monitor your heater, and call your dealer.

Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in this heater. Keep all such liquids well away from the heater while it is in use.

Do not store solid fuel or place such fuel within heater installation clearances or within the space required for charging and ash removal.

Do not unplug the heater if you suspect a malfunction. Press the “STOP” button and periodically inspect the heater.

Do not alter this appliance in any way

Ashes should be placed in a metal container with a tight-fitting lid. The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have been thoroughly cooled.

Never try to repair or replace any part of the heater unless instructions are given in this manual. All other work should be done by a trained technician.

Do not alter this appliance in any way.

The viewing door and ashpan must be closed and latched during operation.

This unit must be properly installed to prevent the possibility of a house fire. The instructions must be strictly adhered to. Do not use makeshift methods or compromise in the installation.

This heater is designed and approved for pelletized wood fuel only.

Ok

Gas

ASHES

Page 76: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Safety Precautions 5

© Travis Industries 10/8/18- 1270 AGP Stove

Allow the appliance to cool completely before carrying out any maintenance or cleaning.

Maintain the door and glass seal and keep them in good condition. Do not operate this heater with broken or missing glass. Do not slam the door or strike the glass.

Notify your dealer to replace the glass if glass on this appliance is broken or damaged.

Do not operate the heater if the flame becomes dark and sooty or if the fire platform overfills with pellets. Press the “STOP” button and periodically inspect the heater.

Do not place clothing or other flammable items on or near this appliance.

The heater will not operate during a power outage.

This heater must be connected to a standard115 V., 60 Hz grounded electrical outlet. Do not use an adapter plug or sever the grounding plug. Do not route the electrical cord underneath, in front of, or over the heater.

Keep foreign objects out of the hopper.

The exhaust system must be completely airtight and properly installed. The pellet vent joints must be sealed with RTV 500 F. (260 C.) silicone sealant.

Your heater requires periodic maintenance and cleaning (see "Stove Maintenance"). Failure to maintain your heater may lead to accumulation of soot, creosote, and ash, and smoke spillage or fire in your home.

When installed in a mobile home, the heater must be bolted to the floor, have outside air, and NOT BE INSTALLED IN THE BEDROOM (per H.U.D. requirements). Check with local building officials.

���

WARNING: This wood heater has a manufacturer-set minimum low burn rate that must not be

altered. It is against federal regulations to alter this setting otherwise operate this wood heater

in a manor inconsistent with operating instructions in this Manual.

Page 77: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

6 Safety Precautions

© Travis Industries 10/8/18- 1270 AGP Stove

Do not throw this manual away. This manual has important operating and maintenance instructions that you will need at a later time. Always follow the instructions in this manual.

Disconnect the power before performing any maintenance.

The exhaust system should be checked at least twice a year for any build-up of soot or creosote.

Travis Industries, Inc. grants no warranty, implied or stated, for the installation or maintenance of your appliance, and assumes no responsibility of any consequential damage(s).

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.

Soot and Flyash: Formation and Need for Removal – The products of combustion will contain small particle of flyash. The flyash will collect in the exhaust venting system and restrict the flow of the flue gases. Incomplete combustion, such as occurs during startup, shutdown, or incorrect operation of the room heater will lead to some soot formation which will collect in the exhaust venting system. The exhaust venting system should be inspected at least twice every year to determine if cleaning is necessary.

NEVER USE SUBSTITUTE MATERIALS FOR ANY PURPOSE ON THIS APPLIANCE.

Establish a routine for fuel, wood burner and firing technique. Check for creosote build-up daily until you know how often to clean the appliance for safe operation. Be aware that the hotter the fire, the less creosote is deposited, and weekly cleaning may be necessary in mild weather even though monthly cleaning may be enough in the coldest months. Contact your municipal or provincial fire authority for information on how to handle a chimney fire. Have a clearly understood plan in place for how to handle a chimney fire.

Do not burn this stove if unburned pellets are in the ashpan. These should be removed as they may ignite.

Smoke and CO Detectors: Make sure your home has a working smoke detector, especially near any bedrooms. We recommend having a smoke and/or CO detector in the same room as the wood heater for additional safety.

Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. California Health & Safety Code Sec. 25249.6

U.S. and Foreign Patents Pending.

ThisManual

Page 78: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Installation (For Qualified Installers Only) 7

© Travis Industries 10/8/18- 1270 AGP Stove

Heating Specifications Approximate Maximum Heating Capacity (in square feet)* ............................................ 800 to 2,000 Sq. Feet BTUs .............................................................................................................................. 11,480 to 41,000 ** Burn Rate (Pounds per Hour)*** .................................................................................... 1.4 to 5 Maximum Burn Time on Low Burn*** ............................................................................. 57 Hours Hopper Capacity ............................................................................................................ 80 Pounds Turn-Down Ratio ............................................................................................................ 71%

* Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature. It is also affected by the fuel size, quality, and moisture level.

** Based on 8,200 BTUs.per pound

*** Small pellet size will decrease the stated burn rates and burn times. Differences of plus or minus 20% depending on fuel quality may occur.

Dimensions

Electrical Specifications Electrical Rating ...................................................................................................... 115 Volts, 3 Amps, 60 Hz Watts during Start-Up Sequence ............................................................................ 350 (approximately) Watts during Operation ........................................................................................... 250 (approximately)

Fuel This heater is designed and approved for pelletized wood fuel only (all grades). Travis Industries Inc. recommends using only fuel that is certified by the Pellet Fuels Institute (PFI).

Emissions

This heater meets the 2020 U.S. EPA’s emission limits for pellet stoves. Report# 0028PS108E Tested to ASTM E2779-10, ASTM 2515-11, CSA B415.1-10 this heater has been shown to deliver heat at rates ranging from 12,806 to 43,428 BTU/hr and an emission value of 1.80g/h.BTU/hr.

Efficiency This model was tested for efficiency using method B415.1-10 and was determined to have a weighted average higher heating Value (HHV) Overall Heating Efficiency (OHE) of 75.6%. Overall efficiency of the heater may be lower if the heater is operated with the heat exchange blower is on low.

3" (77mm) Dia. Exhaust (centered on appliance)

1.75" (45mm) Dia. Air Intake16.5" (420mm)

3.5" (89mm)

24.25" (616mm)

25.25"(642mm)

17.5"(445mm)

3" (77mm) Dia. Exhaust

1.75" (45mm)Dia. Air Intake

33"(839mm)

42.25"(1074mm)

7.25" (185mm)

5.75" (147mm)

Page 79: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

8 Installation (For Qualified Installers Only)

© Travis Industries 10/8/18- 1270 AGP Stove

Before You Begin

READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THIS HEATER. FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.

Check with local building officials for any permits required for installation of this pellet heater and notify your insurance company before proceeding with installation.

Packing List

Items Required AGP Pellet Stove Side Panels (SKU 94400024, 94400025, or 94400026)

Installation Options Residential or Mobile Home (see the section "Mobile Home Requirements")

Alcove Compatible (see the section "Alcove Installation")

Horizontal or Vertical Vent

Outside Air Compatible

Vent with L-Vent, L-Vent Fireplace Liner, or Type “A” Chimney (with adapter)

Cleaning tool

Brush

Bottle Brush

Fuses

Burn Platform Wedge

Page 80: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Installation (For Qualified Installers Only) 9

© Travis Industries 10/8/18- 1270 AGP Stove

Planning the Installation HINT: Have an authorized Travis Industries dealer install this heater. If you install the

heater yourself, have your dealer review your installation plans. HINT: Sketch out a detailed plan of the installation including dimensions. Then verify the

dimensions with the requirements listed in this manual. HINT: When determining the location of the stove, locate the wall studs (for horizontal

penetrations) and ceiling trusses (for vertical penetrations). You may wish to adjust the stove position slightly to ensure the vent does not intersect with a framing member.

The location of your wood heater in your home will decide how affectively the heat produced will spread throughout your house. Attention to the home design with consideration of natural convection and air circulation should be taken into account when choosing the placement of your heater within the home.

Stove Placement Stove must be placed so that no combustibles are within, or can swing within (e.g. drapes,

doors), 36" (915mm) of the front of the heater.

If the stove is placed in a location where the ceiling height is less than 7' (2.134 M), it must follow the requirements in the section "Alcove Installation Requirements".

HINT: REDUCING CLEARANCES - Clearances may be reduced by methods specified in NFPA 211, listed wall shields, pipe shields, or other means approved by local building or fire officials.

Heater and floor protection must be installed on a level, secure floor.

Floor Protection Requirements The heater must be installed on a non-combustible floor protector extending the full width and

depth of the heater and extending 6" (153mm) in front (minimum .018" thick - 26 gauge).

Must extend under and 2" (51mm) to each side and rear of a "Tee" (if used).

Electrical Requirements

This heater requires a standard 120 volt, 60 Hz grounded electrical outlet. Do not use an adapter plug or sever the grounding plug.

This heater requires correct polarity. The line (hot) is on the right and has a smaller plug. The neutral (common) is on the left and has a larger plug. Use a circuit tester (available at hardware stores) or contact an electrician to verify correct polarity and ground.

WARNING: Connection to a reverse polarity or un-grounded circuit may damage your heater’s circuit board. This may cause a safety hazard, improper operation, and void your warranty.

Do not route the electrical cord underneath, in front of, or over the heater.

Page 81: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

10 Installation (For Qualified Installers Only)

© Travis Industries 10/8/18- 1270 AGP Stove

Clearances

Straight Installations

Corner Installations

* Install the vent at the clearance specified by the vent manufacturer.

NOTE: If an interior vertical vent is used, the stove to backwall dimension is determined by the vent being used. This dimension will vary depending on the brand of pellet vent used. To determine the distance from the backwall to the stove, connect the "Tee" and add the vent clearance.

** The floor protection must extend 2” (51mm) beyond the pipe – all vent clearances must be met.

6” Minimum

6” Minimum

2” Minimum**

“Tee”3” Minimum

6” Minimum

Through the Wall Installations Interior Vertical Vents

Floor Protection6” Minimum

Vent Clearance*

Through the Wall Vents

6” Minimum

3” Minimum45° Elbow

45°

Interior Vertical Vents

3” Minimum

6” Minimum

2” Minimum*

3” Minimum

“Tee”Vent

Clearance*

3” Minimum

Page 82: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Installation (For Qualified Installers Only) 11

© Travis Industries 10/8/18- 1270 AGP Stove

Venting the Pellet Stove INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.

DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE OR STOVE.

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.

USE AN APPROVED WALL THIMBLE WHEN PASSING THE VENT THROUGH WALLS AND A CEILING SUPPORT/FIRE STOP SPACER WHEN PASSING THE VENT THROUGH CEILINGS (MAKE SURE TO MAINTAIN CLEARANCE TO ANY COMBUSTIBLES).

No more than one tee and 180° of elbows (one tee with two 90° elbows, one tee with one 90° and two 45° elbows, etc.).

Maximum Venting Distance

Vent must have a support bracket every 5' (1.524 M) of pellet vent when on exterior of structure.

NOTE: Travis Industries recommends a minimum vertical vent of 5’ to ensure adequate draft during a power outage.

0 F

eet

5 F

eet

10 F

eet

(max

.)

0 F eet

5 F eet

10 F eet

15 F eet

20 F eet

25 F eet

30 F eet

T he vent height and run must not exceed the distance shown in the shaded region shown to the right.

NOT E : T o achieve optimum performance, we recommend keeping the vent as short as poss ible (horizontal run especially).

V enting into this shaded area may require restrictor adjustments . S ee the section “R estrictor Adjustment” for details .

35 F eet

40 F eet(max.)

Page 83: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

12 Installation (For Qualified Installers Only)

© Travis Industries 10/8/18- 1270 AGP Stove

Pellet Vent Type

Must be 3" (76mm) or 4” (102mm) diameter Type "L" (except for masonry fireplace installations) - or - connect the vent to a factory built type "A" chimney. All vent joints (including adapters, elbows, etc.) must be sealed (typically 500° F. RTV silicone is used).

Installing the Pellet Vent

Horizontal sections must have a 1/4" (6.4mm) rise every 12" (305mm) of travel.

Pellet vent connections must be sealed airtight with 500° F. RTV silicone and screwed together with at least 3 sheet metal screws (unless the vent manufacturer’s requirements specify otherwise).

Pellet Vent Termination

Vent must terminate on the exterior of the dwelling. Horizontal terminations must protrude a minimum of 12" (305mm) from the wall. Vertical terminations must protrude a minimum 24" (610mm) from the roof surface. In addition, all clearances listed below must be met.

Must have an approved cap (to prevent water from entering) or a 45° downturn with rodent screen.

If the termination is located on a windy side of the house, an approved house shield is recommended to prevent soot from building up on the side of the house.

Must not be located where it will become plugged by snow or other material.

A Minimum 4' (1220mm) clearance below or beside any door or window that opens. (This clearance may be reduced to18” if using outside air (see page 13) – we recommend the door or window be kept closed during operation. Minimum 1’ (458mm) clearance below or beside any window that does not open.

B Minimum 1' (458mm) clearance above any door or window that opens C Minimum 2' (610mm) clearance from any adjacent building

D Minimum 7' (2.134 M) clearance above any grade when adjacent to public walkways

NOTE: Vent may not terminate in covered walkway or breezeway.

E Minimum 2' (610mm) clearance above any grass, plants, or other combustible materials F Minimum 3' (915mm) clearance from any forced air intake of any other appliance G Minimum 2' (610mm) clearance below eaves or overhangs H Minimum 1' (458mm) clearance horizontally from combustible wall X Must be a minimum of 2' (610mm) above the roof

Seal each vent section (including adapters, elbows, etc...) by injecting a liberal amount of 500° F. RTV silicone into the gap between sections.

500° F. R

TV

Silicone

H

G

A

D

F

NOTE: Measure clearances to the nearest edge of the exhaust hood.

A

E

B

C

F

X

H

Install the vent at the clearance specified by the vent manufacturer.

Page 84: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Installation (For Qualified Installers Only) 13

© Travis Industries 10/8/18- 1270 AGP Stove

Mobile Home Requirements Outside air is required (used for combustion) - see the directions below.

The heater must be bolted to the floor (Some states do not require this; check with your local building department).

The heater must be grounded to the steel chassis of the mobile home (Some states do not require this; check with your local building department).

DO NOT INSTALL IN SLEEPING ROOM.

CAUTION: THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED.

Outside Air (Used for Combustion Use Part #99200136) Travis Industries strongly recommends outside air for all installations, especially for those with relatively air-tight homes or with vents that do not include vertical rise.

Must not be drawn from an enclosed space (garage, unventilated crawl space).

Must not be over 48” (1220mm) long

Must be made with 1-¾” (45mm) diameter or larger metal or aluminum duct with a metal screen attached to the end to keep out rodents (P.V.C. or other combustible materials may not be used). We recommend the Travis Industries Outside Air Kit (part # 99200136).

Must not terminate above or within 1' (305mm) of the chimney termination.

Must have a rain cap or down-turned elbow to prevent water from entering.

Must be located so that it will not become plugged by snow or other material.

Page 85: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

14 Installation (For Qualified Installers Only)

© Travis Industries 10/8/18- 1270 AGP Stove

Alcove Installation Requirements When the pellet stove is placed in a location where the ceiling height is less than 7' (2.134 M) tall, it is considered an alcove installation. Because of the reduced height, the requirements listed below must be met.

Minimum height is 60"

Minimum width is 36-9/16"

Maximum depth is 48"

Minimum clearance of 6" on each side and 3" on back

Minimum clearance of 3” for horizontal venting

Minimum clearance of 2” from pipe for vertical venting

Restrictor Adjustment For installations with a tall flue, the restrictor may be needed to adjust airflow to the fire platform. This keeps the fire platform and glass as clean as possible.

For low heat output settings the restrictor may need to be closed or near closed to limit the amount of air. This prevents the stove from burning the pellet fuel faster than it is fed.

For medium heat output settings the restrictor may need to be opened to a medium position.

For high heat output settings the restrictor will need to be opened to a high position. This prevents the fire platform from over-filling with pellets and becoming clogged with ash clumps.

Keeping your fire platform clean is the most important step to maintaining a safe and efficient stove. Check and clean your fire platform daily until you find the correct restrictor settings and appropriate fire platform cleaning interval.

Not Enough Air

If clinkers (ashes that solidify into a clump) develop or the flame appears lazy and slow to blow the ash out of the fire platform, push the restrictor in until the flame becomes active and the fire platform holes remain clean.

NOTE: If the restrictor is fully in, yet the fire platform does not remain clean, the stove needs to be cleaned and checked for air leaks (see “Maintenance” section of this manual).

Too Much Air

If the flames are too active (small, flickering flames), move the restrictor rod out until the flame slows down.

NOTE: It is acceptable to have “glowing embers” jump out of the fire platform. Another symptom of too much air is the heater “blowing the fire out” – a condition in which the pellets burn faster than they are fed (this is most common on low heat settings).

More Air

Less Air

Page 86: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Installation (For Qualified Installers Only) 15

© Travis Industries 10/8/18- 1270 AGP Stove

Installation Examples

Installation Example: Direct "Through-the-wall" Installation

NOTE: Travis Industries recommends a minimum vertical vent of 5’ to ensure adequate draft during a power outage.

Install the vent at the clearance specified by the vent manufacturer.

Floor Protection

House Shield (used to protect

exterior wall from soot

discoloration) is HIGHLY

RECOMMENDED

12” Minimum

Horizontal Rain Cap

Wall Thimble (note clearance between vent and combustibles)

Type "L" Vent

12” Minimum

3” Minimum

Floor Protection

Seal each vent

section (including

adapters, elbows,

etc...) by injecting a

liberal amount of

500° F. RTV

silicone into the gap

between sections, unless otherwisespecified by the manufacturer.

500° F. RTV

Silicone

3” Minimum

6” Minimum

6” Minimum

Page 87: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

16 Installation (For Qualified Installers Only)

© Travis Industries 10/8/18- 1270 AGP Stove

Installation Example: Interior Vertical Installation

* Install vent at clearance specified by the vent manufacturer.

��������������������������������

Floor Protection

Outside air may be drawn from a ventilated crawl space.

2” Min.

Vent Clearance*

������������������������������������������������������������������������������������������������������������������������

���������������

���������������

������

����������������

������

������

��������������

24” Minimum

Insulation must maintain clearance.

2” Min.

Ceiling Support / Fire Stop Spacer

Roof Flashing

Storm Collar

Vertical Cap

Vent must maintain clearance to combustibles.

“L” Vent

Seal each vent section (including adapters, elbows, etc...) by injecting a liberal amount of 500° F. RTV silicone into the gap between sections.

500° F. R

TV

Silicone

Vent Clearance*

Floor Protection

������������������������������������������������������������������������������������������������

6” Minimum

6” Minimum

2” Minimum

“Tee”

Vent Clearance*

7-1/4”

Each manufacturer’s “T” section varies in height. Make sure to measure the “T” prior to installation to verify it fits.

Page 88: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Installation (For Qualified Installers Only) 17

© Travis Industries 10/8/18- 1270 AGP Stove

Installation Example: Class “A” Chimney Retrofit

* Install vent at clearance specified by the vent manufacturer.

Floor Protection

Outside air may be drawn from a ventilated crawl space.

2” Min.

Class A Chimney Ceiling Support

Roof Flashing

“L” Vent to Class A Chimney Adapter

Class A Chimney

“L” Vent

Storm Collar

Class A Chimney must maintain clearances outlined in the chimney’s installation instructions (usually 2”).

Seal each vent

section (including

adapters, elbows,

etc...) by injecting a

liberal amount of

500° F. RTV

silicone into the gap

500° F. RTV

Silicone

Floor Protection

6” Minimum

6” Minimum

2” Minimum

“Tee”

Vent Clearance*

Vent Clearance*

between sections, unless otherwisespecified by the manufacturer.

Page 89: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

18 Installation (For Qualified Installers Only)

© Travis Industries 10/8/18- 1270 AGP Stove

Installation Example: Masonry Fireplace Hearth Stove

“L” Vent Flex

Section

Outside air

may be

drawn from

the ash

cleanout. 6” Min.

“L” Vent

Storm Collar

Vertical Cap

Cover Plate (non-combustible)

Silicone Seal the cover plate with silicone.

NOTE: you may need a short horizontal section here to

clear the lintel and allow the hopper lid to open.

Lintel

Seal each vent

section (including

adapters, elbows,

etc...) by injecting a

liberal amount of

500° F. RTV

silicone into the gap

500° F. RTV

Silicone

Allow room for the

hopper lid to open

between sections, unless otherwisespecified by the manufacturer.

Page 90: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Installation (For Qualified Installers Only) 19

© Travis Industries 10/8/18- 1270 AGP Stove

Installation Example: Zero-Clearance (Metal) Fireplace Hearth Stove

“L” Vent Flex Section

6” Min.

“L” Vent

Storm Collar

Vertical Cap Cover Plate (non-combustible)

Silicone Seal the cover plate with silicone.

NOTE: you may need a short horizontal section here to clear the lintel and allow the hopper lid to open.

Allow room for the hopper lid to open

Seal each vent section (including adapters, elbows, etc...) by injecting a liberal amount of 500° F. RTV silicone into the gap

500° F. RTV

Silicone

between sections, unless otherwisespecified by the manufacturer.

Page 91: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

20 Installation (For Qualified Installers Only)

© Travis Industries 10/8/18- 1270 AGP Stove

Installation Example: Freestanding Masonry Chimney

* Install vent at clearance specified by the vent manufacturer.

6” Min.

“L” Vent Sections

“L” Vent

Storm Collar

Vertical Cap

Cover Plate (non-combustible)

Silicone Seal the cover plate with silicone.

Clean-Out Access

Seal each vent

section (including

adapters, elbows,

etc...) by injecting a

liberal amount of

500° F. RTV

silicone into the gap

500° F. RTV

Silicone

“L” Vent Flex Section

Vent Clearance*

between sections, unless otherwisespecified by the manufacturer.

Page 92: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Operation 21

© Travis Industries 10/8/18- 1270 AGP Stove

Safety Notice READ THIS ENTIRE MANUAL (ESPECIALLY THE "SAFETY PRECAUTIONS" ON PAGES 4 AND 5) BEFORE USING THIS STOVE. FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.

DO NOT UNPLUG THE STOVE TO TURN IT OFF. THIS STOVE RELIES UPON ELECTRICITY TO PUSH THE FLUE GASES OUT THE PELLET VENT – UNPLUGGING IT MAY LEAD TO SMOKE ENTERING YOUR ROOM.

FAILURE TO MAINTAIN YOUR HEATER WILL LEAD TO A RESTRICTED COMBUSTION AIR SYSTEM, LEADING TO POOR PERFORMANCE AND IN SOME CASES, SMOKE SPILLAGE INTO THE ROOM. SEE THE "MAINTENANCE" SECTION FOR DETAILS.

DO NOT USE CHEMICALS OR FLAMMABLE FLUIDS TO START THIS HEATER.

Location of Controls The control panel is located at the top back of the stove as shown below. Open the control panel door to access the controls.

IMPORTANT: Do not let the control panel door bang open, it may scratch if it hits the stove top surface.

TSTATSTOP

HEAT FANAUTO FAN

LOW HIGHwww.travisproducts.com

GLASS AND SURFACES OF UNIT CAN GET HOT ENOUGH

TO CAUSE SEVERE BURNS.KEEP CHILDREN AND PETS AWAY.

WARNING

START

LOW HIGH

Page 93: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

22 Operation

© Travis Industries 10/8/18- 1270 AGP Stove

Loading Pellets Lift the hopper lid to its vertical position. Pour pellets into the hopper.

NOTE: If the hopper lid is opened for more than 1 minute, the stove will enter shut down cycle. If this happens, simply restart the stove.

WARNING: The stove top becomes hot during operation. Make sure to keep any flammable items (bag of pellets) away from the top while reloading.

NOTE: The stove will not run if the lid is open.

Starting the Heater for the First Time Start the Heater - Let it Burn for 1 Hour - THEN OPEN THE DOOR. The stove paint is cured through heat. To prevent it from bonding to the door gasket, you must burn the heater for approximately 1 hour, then open and close the door to break any bonding.

Curing the Paint

This stove uses a heat-activated paint that will emit some fumes while starting the first fire. Open doors and windows to the room to vent these fumes. You may also notice oil burning off of the interior of the stove. This rust-stopping agent will soon dissipate. Allow 48 hours for the paint to cure.

�������

����

2 to 4 hoursAllow 48 hours

Page 94: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Operation 23

© Travis Industries 10/8/18- 1270 AGP Stove

Manual Mode Manual mode requires the user to turn the heater on and off manually and select the heat output setting.

To Start

Press the START button on the control panel. The stove will enter the start-up sequence for approximately 22 minutes.

To Shut Down

Press the STOP button on the control panel. The stove will begin the shut-down process, which takes approximately 45 minutes.

To Adjust the Heat

Turn the HEAT knob on the control panel to the left (lower heat) or right (higher heat). The HEAT knob adjusts the rate of pellets feeding into the stove.

TSTATSTOP

HEAT FANAUTO FAN

LOW HIGHwww.travisproducts.com

GLASS AND SURFACES OF UNIT CAN GET HOT ENOUGH

TO CAUSE SEVERE BURNS.KEEP CHILDREN AND PETS AWAY.

WARNING

START

LOW HIGH

TSTATSTOP

HEAT FANAUTO FAN

LOW HIGHwww.travisproducts.com

GLASS AND SURFACES OF UNIT CAN GET HOT ENOUGH

TO CAUSE SEVERE BURNS.KEEP CHILDREN AND PETS AWAY.

WARNING

START

LOW HIGH

TSTATSTOP

HEAT FANAUTO FAN

LOW HIGHwww.travisproducts.com

GLASS AND SURFACES OF UNIT CAN GET HOT ENOUGH

TO CAUSE SEVERE BURNS.KEEP CHILDREN AND PETS AWAY.

WARNING

START

LOW HIGH

Page 95: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

24 Operation

© Travis Industries 10/8/18- 1270 AGP Stove

To Adjust Heat Output

Turn the FAN knob on the control panel to the left (lower fan) or right (higher fan). The FAN knob adjusts the speed of the stove’s blower to move more heat out into the room.

Auto-Fan

Turn the FAN knob to the AUTO-FAN setting on the control panel to automatically adjust the fan speed based on the feed rate into the hopper. This allows for more efficient operation.

TSTATSTOP

HEAT FANAUTO FAN

LOW HIGHwww.travisproducts.com

GLASS AND SURFACES OF UNIT CAN GET HOT ENOUGH

TO CAUSE SEVERE BURNS.KEEP CHILDREN AND PETS AWAY.

WARNING

START

LOW HIGH

TSTATSTOP

HEAT FANAUTO FAN

LOW HIGHwww.travisproducts.com

GLASS AND SURFACES OF UNIT CAN GET HOT ENOUGH

TO CAUSE SEVERE BURNS.KEEP CHILDREN AND PETS AWAY.

WARNING

START

LOW HIGH

Page 96: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Operation 25

© Travis Industries 10/8/18- 1270 AGP Stove

TSTAT (Thermostat) Mode

TSTAT mode allows you to use a thermostat to control room temperature. The stove automatically turns on when the temperature drops below the thermostat setting and turns off (or to low) once the thermostat setting is met.

Wireless thermostats are available from Travis Industries. See your dealer for details.

To Start the Stove in TSTAT Mode

Press the TSTAT button on the control panel. If there is a call for heat from the thermostat, the stove will enter the start-up sequence for approximately 22 minutes.

To Adjust the Heat Output

Use the HEAT knob on the control panel to adjust the heat output.

NOTE:

Depending upon which TSTAT Program you are in (1, 2, or 3), the heat output may vary once the target temperature is reached. For details see “Changing the TSTAT Program” on the following page.

TIP:

If you find that the stove turns on and off repeatedly, you may wish to turn the heat output to a lower setting, which will provide a more consistent heat output over time, and eliminate the need for the thermostat to repeatedly turn the stove off.

To Shut Down

Press the STOP or TSTAT button on the control panel or turn the thermostat down below the room temperature. The stove will begin the shut-down process, which takes about approximately 45 minutes.

TSTATSTOP

HEAT FANAUTO FAN

LOW HIGHwww.travisproducts.com

GLASS AND SURFACES OF UNIT CAN GET HOT ENOUGH

TO CAUSE SEVERE BURNS.KEEP CHILDREN AND PETS AWAY.

WARNING

START

LOW HIGH

TSTATSTOP

HEAT FANAUTO FAN

LOW HIGHwww.travisproducts.com

GLASS AND SURFACES OF UNIT CAN GET HOT ENOUGH

TO CAUSE SEVERE BURNS.KEEP CHILDREN AND PETS AWAY.

WARNING

START

LOW HIGH

Page 97: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

26 Operation

© Travis Industries 10/8/18- 1270 AGP Stove

Changing the TSTAT Program

This heater comes with three TSTAT programs built in. Each program is unique and allows you to modify your thermostat setting to your preference. The stove is shipped pre-programmed in TSTAT program 1.

How to Tell Which TSTAT Program You Are In

When the heater is placed in thermostat mode (TSTAT button pressed), the BLUE light will flash once, twice, or three times. This will let the operator know which thermostat program the heater in. One blue flash indicates thermostat program 1. Two blue flashes indicates program 2. Three blue flashes indicates program 3.

Switching Between Program 1, 2, and 3

Each time you press the “STOP” and “TSTAT” button simultaneously while the unit is cold, the TSTAT program will toggle to the next program. Continue to press these two buttons until the blue Auto-Fan LED light flashes the program you wish to use.

Thermostat Program 1

When the thermostat stops calling for heat (the thermostat is open) the thermostat “steps down” to a lower heat setting. The heater will stay at this setting for 15 minutes. If the thermostat does not call for heat, the thermostat will “step down” again to a lower setting (or off). At any time if the thermostat calls for heat (thermostat is closed) during this cycle, the heater will resume at the HEAT output setting set at the control board.

Heater Set at

HIGH

If thermostat calls for heat (thermostat closed)

Heater runs at setting set on control panel dial.

If thermostat stops calling for heat (thermostat open)

Heater goes to MEDIUM. If after 15 minutes thermostat still open, heater goes to MEDIUM-LOW. If after 15 minutes thermostat still open, heater goes to LOW. If after 15 minutes thermostat still open, heater turns off.

Heater Set at

MEDIUM

If thermostat calls for heat (thermostat closed)

Heater runs at setting set on control panel dial.

If thermostat stops calling for heat (thermostat open)

Heater goes to MEDIUM-LOW. If after 15 minutes thermostat still open, heater goes to LOW. If after 15 minutes thermostat still open, heater turns off.

Heater Set at

MEDIUM-LOW

If thermostat calls for heat (thermostat closed)

Heater runs at setting set on control panel dial.

If thermostat stops calling for heat (thermostat open)

Heater goes to LOW. If after 15 minutes thermostat still open, heater turns off.

Heater Set at

LOW

If thermostat calls for heat (thermostat closed)

Heater runs at setting set on control panel dial.

If thermostat stops calling for heat (thermostat open)

Heater will run for 15 minutes. If thermostat still open, heater turns off.

NOTE: This program is not recommended for areas with little heating requirements (mild climates, small rooms, etc.).

Thermostat Program 2

In Thermostat Mode Program 2 when the thermostat stops calling for heat (the thermostat is open) the following happens:

The burn rate decreases to Level 1 (low) for 15 minutes. If there is no call for heat during that time…

The unit turns off.

If there is a call for heat by the thermostat (the thermostat is closed) at any point during this cool-down period then the burn rate resumes corresponding with the setting on the control panel.

Thermostat Program 3

In Thermostat Mode Program 3 when the thermostat stops calling for heat (the thermostat is open) the following happens:

The burn rate decreases to Level 1 (low) and remains at this level until there is a call for heat by the thermostat (the thermostat is closed), then resumes corresponding with the setting on the control panel.

Page 98: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Operation 27

© Travis Industries 10/8/18- 1270 AGP Stove

Start-Up Sequence (Igniter) The stove enters a start-up sequence whenever there is a call for heat and the unit isn’t in Run mode. This is ensures proper operation through all possible settings and operational states (hot or cold, pellets burning or not burning, etc.), and overrides all user settings (except the OFF position). During this period the START light will flash. The stove will not enter start-up if you are loading pellets into the hopper. During the start-up sequence, the pellets will load into the fire platform, the flame will ignite, and the room air blower will come on when the heater comes up to the selected temperature. NOTE: If the heater doesn’t light 2 times in a row, both the START and STOP lights will turn on. The combustion blower will run for about an hour before shutting off. Check to make sure there are pellets in the hopper. We recommend cleaning the burn pot and making sure all air ports are clear of debris. Reset the unit by unplugging it and then plugging it back in.

Power Outages

Because this stove relies upon a blower to evacuate smoke, some smoke may enter the home during a power outage. Leave the door closed to keep the possibility of smoke spillage to a minimum.

NOTE: Travis Industries recommends a minimum vertical vent of 5’ to ensure adequate draft during a power outage.

After a power outage (or when plugging the heater in) the exhaust blower will run for approx. 15 minutes. This is a safety feature used to vacate smoke in case of a power outage.

Manual Mode

If a power outage occurs when the unit is hot, it will enter the start-up sequence. If the unit has cooled it will enter a cool-down phase (exhaust blower will run up to 20 minutes to ensure smoke evacuation).

TSTAT Mode

If a power outage occurs while in TSTAT mode, the unit will continue to operate. If the thermostat calls for heat, the unit will enter the start-up sequence and restart. If the thermostat does not call for heat it will enter a cool-down phase (exhaust blower will run up to 20 minutes to ensure smoke evacuation).

Normal Operating Sounds

After a power outage (or when plugging the heater in) the exhaust blower will run for approx. 15 minutes. This is a safety feature used to vacate smoke in case of a power outage.

Metering Auger MotorYou will hear this motor turning intermittently as it feeds pellets. You may also hear the pellets drop into the feed tube.

Exhaust BlowerThis blower creates a low-pitched hum. This sound increases as the heat output is increased.

Convection BlowerThis blower produces a slight hum and wind noise. This sound increases as the blower speed is increased.

ChiselThe chisel separates the pellets in the hopper from the feed tube. Occasionally you may hear a "click" as a pellet is sheared.

Creaks and ClicksThe steel may creak or click when the stove heats up and cools down - this is normal.

Page 99: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

28 Maintenance

© Travis Industries 10/8/18- 1270 AGP Stove

Stove Maintenance

The following section details extensive maintenance procedures. We strongly suggest these items be carried out by a trained service technician, possibly by a service agreement set up with your dealer. NOTE: Pellet quality can vary by state and the maintenance schedule may need to be revised to maintain the heater’s effectiveness.

DISCONNECT THE POWER CORD AND MAKE SURE THE HEATER HAS FULLY COOLED (APPROXIMATELY 45 MINUTES) PRIOR TO CONDUCTING SERVICE.

Maintenance Schedule

Weekly Maintenance (or every 5 bags of fuel):

Inspect Burn Clean the fire platform Clean the heat exchange tubes

Monthly Maintenance (or every 20 bags of fuel):

Empty the ashpan Clean vertical exhaust ducts Clean the glass

Yearly Maintenance (or every ton of fuel):

Clean firebox liners Clean lower exhaust duct Clean convection blower Clean negative pressure tube Clean the vent Clean under fire platform Adjust door hinge and latch Check for air leaks

Removing Flyash

This heater was designed to allow for easy flyash removal with the included tools. However, to ease maintenance, several pellet stove owners have purchased vacuums specifically made to remove flyash. Furthermore, some of these vacuums are heat-resistant to allow for flyash removal while it is still warm. DO NOT USE A STANDARD VACUUM ON THIS APPLIANCE (except to clean the pellet dust out of the hopper). Standard vacuums may spread the fine particles inside the flyash into the home and are not heat-resistant (hot flyash may cause the internal portion of vacuums to ignite).

NOTE: Ask your authorized Travis dealer for a recommended ash vacuum.

Disposal of Ashes

Ashes should be placed in a metal container with a tight-fitting lid. The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have been thoroughly cooled.

Page 100: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Maintenance 29

© Travis Industries 10/8/18- 1270 AGP Stove

Stove Maintenance Tools

Included with the stove are three tools for maintenance: a bottle brush, brush and the cleaning tool.

Stove Tool Storage

The stove tools may be stored on the hooks on the back of the stove. To use the hooks for the first time, bend the hooks with a screwdriver or needle-nose pliers, then hang the tools on the hooks as shown below.

Opening the Door

MAKE SURE THE HEATER HAS FULLY COOLED (APPROXIMATELY 45 MINUTES) BEFORE OPENING THE DOOR AND CONDUCTING SERVICE.

Turn the handle clockwise and pull to open the door, as shown below.

Page 101: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

30 Maintenance

© Travis Industries 10/8/18- 1270 AGP Stove

Weekly Maintenance (or Every 5 Bags of Pellets) - Inspect the Burn

Once a week you should inspect the flame quality inside your appliance. When burning on high, the flames should be bright orange. If the flames seem to be coming only from the sides, or are orange/black, turn the heater off and check for clinkers (ashes that solidify into a clump). The most likely causes of clinkers are:

Restrictor needs adjustment (see “Restrictor Adjustment” in the Installation section of this manual) NOTE: The optimum restrictor position will vary over time as soot builds up inside the exhaust system. See "Restrictor Adjustment" for details.

Poor pellet quality

The door or glass has an air leak

The exhaust system requires cleaning

Weekly Maintenance (or Every 5 Bags of Pellets) - Clean the Fire Platform

Once a week you should clean and inspect the fire platform. The following steps outline this process. 1. Open the door. 2. Remove the visual deflector. Note how the deflector has two hooks on each side that fit over pins to

the side of the burn platform.

NOTES ON REPLACING THE VISUAL DEFLECTOR

When in place, make sure the visual deflector is pressed down fully on both sides. If it is not fully seated, airflow to the burn platform may be displaced and the appliance may burn poorly.

Page 102: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Maintenance 31

© Travis Industries 10/8/18- 1270 AGP Stove

3. Use the cleaning tool to scrape away hardened clinkers or buildup on the fire platform. Use the narrow tip to clear any plugged holes. The fire platform must be free from buildup for the pellets to burn completely.

4. Brush away flyash around the fire platform using the brush included with the insert. The flyash will fall into the ashpan below.

5 Remove the wedge that locks the burn platform in place. If the wedge is difficult to dislodge, use the

cleaning tool to rock the wedge left to right. NOTE: An extra wedge is included with the heater in case the original is mis-placed.

Brush the flat surfaces to remove flyash

Page 103: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

32 Maintenance

© Travis Industries 10/8/18- 1270 AGP Stove

6 Remove the burn platform from the platform holder.

7 Clean the inside of the burnpot holder.

Page 104: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Maintenance 33

© Travis Industries 10/8/18- 1270 AGP Stove

Weekly Maintenance (or Every 5 Bags of Pellets) - Clean the Heat Exchange Tubes

The heat exchange tubes may accumulate ash when the appliance is in use. To clean, follow the directions below. 1. With the door closed, pull the stove grill up and forward as shown below.

NOTE: Use both hands on the grill. Using one hand in the middle of the grill may cause it to warp.

2. Hook the cleaning tool onto the heat exchange scraper rod as shown below.

3. Move the scraper rod back and forth a few times to clean the heat exchange tubes.

Page 105: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

34 Maintenance

© Travis Industries 10/8/18- 1270 AGP Stove

Cleaning Behind the Firebox Liners

Front View of Firebox Liners

Isometric View (note how the top liner has a flange that bends down)

The firebox liners help trap flyash before it enters the exhaust blower. Remove the liners and clean the area behind them following the directions below.

1. Open the door. 2. Remove the top liner. It is held in place with 3 tabs at the bottom and one large tab (and slot) on

the sides. To remove, lift it up and slide it out.

3. Remove the side liners. They have keyhole slots that fit over screws on the side of the firebox. Lift them up, tilt them inwards, then remove.

Page 106: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Maintenance 35

© Travis Industries 10/8/18- 1270 AGP Stove

4. Remove the rear liner. Lift it up and remove it from the firebox.

5. With the liners removed, clean all flyash and debris from the firebox. Clean the liners before replacing.

Monthly Maintenance (or Every 20 Bags of Pellets) - Clean the Glass

Open the doors and clean the glass with a non-abrasive glass cleaner and rag.

Page 107: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

36 Maintenance

© Travis Industries 10/8/18- 1270 AGP Stove

Monthly Maintenance (or Every 20 Bags of Pellets) – Empty the Ashpan

MAKE SURE THE HEATER HAS FULLY COOLED (APPROXIMATELY 45 MINUTES) BEFORE CONDUCTING SERVICE.

THE ASHPAN MUST BE IN PLACE WHILE THE HEATER IS IN USE.

The ashpan will accumulate ash as you use the appliance. See the steps below to empty the ashpan. 1. Rotate the ashpan handle clockwise and pull it down to access the ashpan.

2. Slide the ashpan forward. Use the built-in rod to lift the ashpan out of the firebox.

NOTE: Do not use the ashpan handle to pull the ashpan out; instead use the lip on the front of the ashpan.

3. Remove the ashpan from the appliance and properly dispose of the ashes (see “Disposal of Ashes” on page 28 for details).

Page 108: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Maintenance 37

© Travis Industries 10/8/18- 1270 AGP Stove

Yearly Maintenance (or Every Ton of Pellets) - Clean the Lower Exhaust Duct

1. With the ashpan removed (see page 36), remove the ashpan guide as shown below. Clean the area under the ashpan guide.

2. Remove the exhaust duct cover as shown below. Press up on it and lift it out.

3. Remove the exhaust channel cover plate and gasket (11/32” nutdriver).

Page 109: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

38 Maintenance

© Travis Industries 10/8/18- 1270 AGP Stove

4. Clean the exhaust channel with the bottle brush or vacuum.

5. Clean the combustion blower with the bottle brush or vacuum.

NOTE: Take care to prevent damaging the combustion blower impellers.

Page 110: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Maintenance 39

© Travis Industries 10/8/18- 1270 AGP Stove

Yearly Maintenance (or Every Ton of Pellets) - Clean the Convection Blower

1. Remove the thumb screw on the left side of the stove. Swing the panel out, slide it forward to remove, and place it aside.

2. Remove the top and bottom screws securing the convection blower cover and remove the cover as shown below (5/16” nutdriver).

3. Remove the 2 nuts securing the blower using a 7/16” nutdriver. Lift out and remove the convection blower from the stove as shown below.

4. Remove all dust and debris from the convection blower.

NOTE: Take care to prevent damaging the impellers.

Page 111: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

40 Maintenance

© Travis Industries 10/8/18- 1270 AGP Stove

Yearly Maintenance (or Every Ton of Pellets) - Clean the Negative Pressure Tube

1. Disconnect the end of the tube from the combustion blower.

2. Clean the nozzle using a pipe cleaner.

Yearly Maintenance (or Every Ton of Pellets) - Clean the Vent

WHENEVER ANY PORTION OF THE PELLET VENT IS DISCONNECTED, THE JOINTS MUST BE SEALED WITH RTV 500° F. SILICONE SEALANT, UNLESS OTHERWISE SPECIFIED BY THE VENT MANUFACTURER.

Check the vent sections for creosote accumulation (indicating a poorly burning stove). Accumulation over 1/4” must be removed.

On vertically vented systems, the dirtiest portion is often the point where the vent turns upwards (i.e. the "Tee"). Fortunately, the "Tee" has a built-in clean-out cover. Place a container under the “Tee”, disconnect the cover and remove all flyash. While open, use a flashlight to look up the vent to check for build-up.

Make sure the cap is free of debris (especially if it has a screen that could become blocked).

Flyash will deposit along sections that are horizontal.

������

������

Page 112: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Maintenance 41

© Travis Industries 10/8/18- 1270 AGP Stove

Yearly Maintenance (or Every Ton of Pellets) - Adjust the Door Cam

The door cam should be tight enough to pull the door against the face of the stove yet not so tight as to not allow full handle rotation. To tighten the door cam, remove the door handle and remove one of the washers between the door frame and cam (the washer may be stored for future use by placing it between the cam and nut). To loosen the door cam, add a washer between the door frame and cam.

NOTE: Older models use 7 washers between the door & cam. Newer models use 1 bushing & 3 washers.

Yearly Maintenance (or Every Ton of Pellets) - Check for Air Leaks Around the Door, Glass, and Ashpan

Air leaks into the firebox will decrease the stove's performance greatly, leading to excessive sooting, inefficient burning, and perhaps a malfunction.

Inspect the door gasket to make sure it is fully attached. If the door gasket is worn or flattened, replace.

If the glass is cracked, replace. The glass is held in place with clips.

Open the ashpan access door and inspect the gasket around the door. Re-attach or replace the gasket if necessary. Re-attach, or replace the gasket if necessary.

NOTE: Ask your authorized Travis dealer to demonstrate how to check a door seal.

Every Two Years (or Every 4 to 6 Tons of Pellets) Chisel Replacement

The chisel is designed to shear pellets during operation.  As the chisel becomes dull over time it will make it harder for the appliance to shear pellets and could shorten the life of the feed motor.  We recommend that the chisel be replaced every two years or 4 to 6 tons of pellets to help ensure proper operation of the appliance.   

To remove the chisel, first remove all pellets from the hopper.  Turn the appliance on and turn the heat rate to “HIGH”.  The hopper lid switch will need to be held in the closed position (AGP appliances) or the hopper lid will need to be closed and you can look through the glass lid (Deerfield & Foxfire stoves) for the feed system to turn.  The chisel will rotate into view (it is the serrated component held in place with two screws).  Once the chisel is in the proper position, unplug the heater and remove the cover plate at the bottom of the hopper (6 screws hold it in place).  The chisel is held in place with two cap head screws (use a 1/8” hex wrench to remove).  Remove the chisel and replace with a new chisel (available from your dealer).  NOTE: There is a shim (2 shims on older units) under the chisel – make sure to replace the shim when installing the chisel. When replacing the cover plate, make sure to place the gasket between the cover plate and hopper (use silicone if gasket is not used).  This prevents pellet dust from falling below.  Return the heater to the correct configuration before operating. 

�����

Door Frame (with gasket)

WashersNut

Door Handle

9/16" Wrench

CamBushing/Washers}

1/4" Nutdriver

1/8” Hex Wrench

Shim

Chisel

Page 113: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

42 Maintenance

© Travis Industries 10/8/18- 1270 AGP Stove

Troubleshooting Table Lights on the control panel will flash when a fault has occurred. Follow the steps below to diagnose.

Diagnostic Code:

Possible Cause:

Don't Call for Service Until You:

RED LIGHT FLASHING Inadequate draft, plugged pressure switch, or push auger error.

Press the STOP button to clear the error code.  Press the START button to re‐ignite the appliance. 

RED & GREEN LIGHTS FLASH SIMULTANEOUSLY

Ignition startup has failed.

NOTE: The 2nd time this happens consecutively, the lights will be solid and appliance will lock out for 1 hour.

Press the STOP button to clear the error code.  Verify the appliance has pellets, clean the burn platform, then restart the appliance. 

BLUE LIGHT FLASHING

Appliance is over-temperature and has entered safety shutdown mode. The appliance will no longer feed pellets and both blowers will remain on until the appliance has cooled sufficiently.

Press the STOP button to clear the error code.  Verify the appliance is clean (free of ash and debris) and the room blower operates (clean if necessary).   

Clean the burn platform then restart the appliance. 

RED & GREEN LIGHTS FLASH ALTERNATELY

Appliance ran out of fuel or hopper lid not fully closed. In rare cases, the metering motor or system disc may have malfunctioned.

Press the STOP button to clear the error code.  Verify the appliance has pellets, the hopper is fully closed, clean the burn platform, then restart the appliance. 

Replacement Parts Contract your Travis Industries Dealer for replacement parts. Use only replacement parts from Travis Industries designed specifically for this heater.

Door Parts

ID # Description Qty Part # ID # Description Qty Part # 1 Glass Gasket (3/8” Diameter) 1 250-02801 2 Glass – Rectangular

Glass - Arched 1 1

250-02073 250-02678

3 Glass Clips w Gasket 1 250-00174 4 Door Gasket (7/8” Diameter) 1 250-00178 5 RTV High Temp. 600° Silicone 6 Door Handle Assembly 1 250-02074 7 Door Knob 1 250-02964 8 Door Washer 1 250-00364 9 Door Cam 1 250-00598 10 Screws (8) 8-32 x 1/2” Torx 1 250-01478

7

89

1

2

�����������������������������������

������������������������������������������

34 10

5

6

Page 114: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Maintenance 43

© Travis Industries 10/8/18- 1270 AGP Stove

Wiring Diagram

AGP PELLET WIRING DIAGRAM6 - Pin

ConnectorRed Wire

White Wire

Black Wire

UncoveredPins

7546

13

2 8

1357

2468

1 3 2 413

24

Optional Remoteor Thermostat

Power CordGround

Hot (fuse)

Common

Blac

kW

hite

Red

White

Whi

teW

hite

Whi

te

White

White

Brow

nBl

ack

Red

Blac

kBl

ack

Brown

Brown

Black

Blac

k

Red

Black

Black

Gree

n

Oran

geOr

ange

Gray

Gray

Control BoardEncoder Molex

ConvectionBlower

PushAuger Motor

MeteringAuger Motor

Igniter

Flow Switch

ExhaustBlower

CeramicSystem Disc

120° NO

Hopper LidSwitch

HopperSnap Disc200° NC

SafetySnap Disc200° NC

ApplianceGround

1004

Page 115: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

44 Optional Equipment

© Travis Industries 10/8/18- 1270 AGP Stove

Thermostat Installation (Optional)

DO NOT CONNECT 120 VAC OR 24V TO THE THERMOSTAT CIRCUIT OF THIS HEATER (DO NOT USE A HOUSEHOLD THERMOSTAT USED FOR A WALL-BOARD OR OTHER ELECTRICAL HEATER). USE A LOW VOLTAGE COMPATIBLE THERMOSTAT.

Wired (99300650) or wireless thermostats (99300689) may be attached to this appliance. Open the left side access panel and locate the wires labeled “TSTAT”. Route the thermostat wires to this location and attach them to these wires (orientation does not matter). Make sure the wires do not contact hot or moving components. See the instructions included with the thermostat for further details.

Outside Air Kit

See the instructions included with the outside air kit for full details.

3/8" Screws

Cover Plate &

1-1/4" screws

1-1/4"

Screws

������������������������������������������������������������������������������������������������������������

���������

������������������������������

���������

���������������������������������������������������������������������������������������������������

���������������������������������������������������������������������������������������������������

1-3/4" Diameter Flex Duct

Select a location between framing

members for the outside air hole.

Hood with Screen

Cut a minimum 2" diameter hole in the wall

(use 2" dia. hole saw).

Silic

one

Seal the area around the

tube to prevent air from

entering through the wall.

Sili

cone

3-1/2"

Cen

terli

ne

5-3/4"���������������

Back of AGP Pellet

Stove

Silic

one

Page 116: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Safety Label 45

© Travis Industries 10/8/18- 1270 AGP Stove

Page 117: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

46 Limited 7 Year Warranty

© Travis Industries 10/8/18- 1270 AGP Stove

Register your TRAVIS INDUSTRIES, INC. Limited 7 Year Warranty online at traviswarranty.com. TRAVIS INDUSTRIES, INC. warrants this gas appliance (appliance is defined as the equipment manufactured by Travis Industries, Inc.) to be defect-free in material and workmanship to the original purchaser from the date of purchase as follows:

Check with your dealer in advance for any costs to you when arranging a warranty call. Mileage or service charges are not covered by this warranty. This charge can vary from store to store.

Years 1 & 2 - COVERAGE: PARTS & LABOR

Firebox Assembly: Fire platform, Fire platform Holder, Ash Cleanout Doors, Ash box or Ash Dump, Heat Exchanger Tubes, Exhaust Manifold, Exhaust Box

Door Assembly: Door Frame, Latch Assembly, Glass Retainers

Auger Assembly: Auger Flight, Auger Tube, Auger Bushings, HRD

Ceramic Glass Glass (breakage from thermal shock)

Igniter System Igniter, Igniter Leads Electrical System Auger Motor, Convection Blower, Exhaust Blower, Circuit Board, Snap Disks, Wiring Harness, Vacuum Switch

Re-Installation Allowance In cases where heater must be removed from home for repairs, a partial cost of re-installation is covered (pre-authorization required)

One-Way Freight Allowance One-way freight allowance on pre-authorized repair done at factory is covered.

Exclusions: Paint, Gasketing, Chisel

Years 3 through 5 - COVERAGE: PARTS & LABOR

Firebox Assembly: Fire platform, Fire platform Holder, Ash Cleanout Doors, Ash box or Ash Dump, Cast Fireback, Heat Exchanger Tubes, Exhaust Manifold, Exhaust Box

Door Assembly: Door Frame, Latch Assembly, Glass Retainers

Auger Assembly Auger Flight, Auger Tube, Auger Bushings, HRD

One-Way Freight Allowance One-way freight allowance on pre-authorized repair done at factory is covered.

Exclusions: Paint, Gasketing, Chisel, Ceramic Glass, Igniter System, Electrical System, Cast Iron Parts, Accessories, Re-Installation Allowance

Years 6 & 7 - COVERAGE: PARTS ONLY

Firebox Assembly: Fire platform, Fire platform Holder, Ash Cleanout Doors, Ash box or Ash Dump, Heat Exchanger Tubes, Exhaust Manifold, Exhaust Box

Door Assembly: Door Frame, Latch Assembly, Glass Retainers

Exclusions: Paint, Gasketing, Chisel, Ceramic Glass, Igniter System, Electrical System, Auger Assembly, HRD, Re-Installation Allowance, One-Way Freight Allowance, Labor

CONDITIONS & EXCLUSIONS 1. This new appliance must be installed by a qualified installer. It must be installed, operated, and maintained at all times in accordance with the instructions

in the Owner’s Manual. Any alteration, willful abuse, accident, neglect, or misuse of the product shall nullify this warranty.

2. This warranty is nontransferable, and is made to the ORIGINAL purchaser, provided that the purchase was made through an authorized Travis dealer.

3. Discoloration and some minor expansion, contraction, or movement of certain parts and resulting noise, is normal and not a defect and, therefore, not covered under warranty.

4. The warranty, as outlined within this document, does not apply to the chimney components or other Non-Travis accessories used in conjunction with the installation of this product. If in doubt as to the extent of this warranty, contact your authorized Travis retailer before installation.

5. Travis Industries will not be responsible for inadequate performance caused by environmental conditions such as nearby trees, buildings, roof tops, wind, hills or mountains or negative pressure or other influences from mechanical systems such as furnaces, fans, clothes dryers, etc.

6. This Warranty is void if:

a. The unit has been operated in atmospheres contaminated by chlorine, fluorine or other damaging chemicals.

b. The unit is subject to submersion in water or prolonged periods of dampness or condensation.

c. Any damage to the unit, combustion chamber, heat exchanger or other components due to water, or weather damage which is the result of, but not limited to, improper chimney/venting installation.

7. Exclusions to this 7 Year Warranty include: injury, loss of use, damage, failure to function due to accident, negligence, misuse, improper installation, alteration or adjustment of the manufacturer's settings of components, lack of proper and regular maintenance, damage incurred while the appliance is in transit, alteration, or act of God.

8. This 7 Year warranty excludes damage caused by normal wear and tear, such as paint discoloration or chipping, worn or torn gasketing, chipped or cracked firebrick, etc. Also excluded is damage to the unit caused by abuse, improper installation, modification of the unit, or the use of fuel other than that for which the unit is configured.

9. Damage to gold or nickel surfaces caused by fingerprints, scratches, melted items, or other external sources left on the gold or nickel from the use of cleaners other than denatured alcohol is not covered in this warranty.

10. TRAVIS INDUSTRIES, INC. is free of liability for any damages caused by the appliance, as well as inconvenience expenses and materials. Incidental or consequential damages are not covered by this warranty. In some states, the exclusion of incidental or consequential damage may not apply.

11. This warranty does not cover any loss or damage incurred by the use or removal of any component or apparatus to or from the Travis appliance without the express written permission of TRAVIS INDUSTRIES, INC. and bearing a TRAVIS INDUSTRIES, INC. label of approval.

12. Any statement or representation of Travis products and their performance contained in Travis advertising, packaging literature, or printed material is not part of this 7 year warranty.

13. This warranty is automatically voided if the appliance’s serial number has been removed or altered in any way. If the appliance is used for commercial purposes, it is excluded from this warranty.

14. No dealer, distributor, or similar person has the authority to represent or warrant Travis products beyond the terms contained within this warranty. TRAVIS INDUSTRIES, INC. assumes no liability for such warranties or representations.

15. Travis Industries will not cover the cost of the removal or re-installation of hearths, facing, mantels, venting or other components.

16. If for any reason any section of this warranty is declared invalid, the balance of the warranty remains in effect and all other clauses shall remain in effect.

17. This 7 year warranty is the only warranty supplied by Travis Industries, Inc., the manufacturer of the appliance. All other warranties, whether express or implied, are hereby expressly disclaimed and purchaser’s recourse is expressly limited to the warranties set forth herein.

Page 118: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

Limited 7 Year Warranty 47

© Travis Industries 10/8/18- 1270 AGP Stove

IF WARRANTY SERVICE IS NEEDED:

1. If you discover a problem that you believe is covered by this warranty, you MUST REPORT it to your Travis dealer WITHIN 30 DAYS, giving them proof of purchase, the purchase date, and the model name and serial number.

2. Travis Industries has the option of either repairing or replacing the defective component.

3. If your dealer is unable to repair your appliance’s defect, he may process a warranty claim through TRAVIS INDUSTRIES, INC., including the name of the dealership where you purchased the appliance, a copy of your receipt showing the date of the appliance’s purchase, and the serial number on your appliance. At that time, you may be asked to ship your appliance, freight charges prepaid, to TRAVIS INDUSTRIES, INC. TRAVIS INDUSTRIES, INC., at its option, will repair or replace, free of charge, your appliance if it is found to be defective in material or workmanship within the time frame stated within this 7 year warranty. TRAVIS INDUSTRIES, INC. will return your appliance, freight charges (years 1 to 5) prepaid by TRAVIS INDUSTRIES, INC., to your regional distributor, or dealership.

4. Check with your dealer in advance for any costs to you when arranging a warranty call. Mileage or service charges are not covered by this warranty. This charge can vary from store to store.

Page 119: Certification Test Report - Travis Industries Report AGP... · 2018. 12. 18. · Travis Industries, Inc. Model: AGP PS Report Number: 0028PS108E OMNI-Test Laboratories, Inc. 1.2 -

48 Index

© Travis Industries 10/8/18- 1270 AGP Stove

Adjust the Door Cam ........................................ 41 Alcove Installation Requirements ..................... 14 Before You Begin ............................................... 8 Changing the TSTAT Program......................... 26 Check for Air Leaks Around the Door, Glass,

and Ashdump ............................................... 41 Checking the Ashpan ....................................... 36 Chisel Inspection & Replacement .................... 41 Clean the Convection Blower ............................ 39 Clean the Fire platform ..................................... 30 Clean the Firebox Liners .................................. 34 Clean the Glass ................................................ 35 Clean the Heat Exchange Tubes ..................... 33 Clean the Lower Exhaust Duct ........................ 37 Clean the Vent ................................................. 40 Clearances ....................................................... 10 Corner Installations .......................................... 10 Curing the Paint ............................................... 22 Dimensions ........................................................ 7 Disposing Ashes .............................................. 28 Efficiency ............................................................ 7 Electrical Specifications ..................................... 7 Emissions ........................................................... 7 Floor Protection Requirements .......................... 9 Fuel .................................................................... 7 Heating Specifications ........................................ 7 Important Information ......................................... 2 Inspect the Burn ............................................... 30 Installation Example: Class “A” Chimney Retrofit

...................................................................... 17 Installation Example: Direct "Through-the-wall"

Installation .................................................... 15 Installation Example: Freestanding Masonry

Chimney ....................................................... 20 Installation Example: Interior Vertical Installation

...................................................................... 16

Installation Example: Masonry Fireplace Hearth Stove ............................................................ 18

Installation Example: Zero-Clearance (Metal) Fireplace Hearth Stove ................................ 19

Installation Options ............................................ 8 Installing the Pellet Vent .................................. 12 Introduction ........................................................ 2 Loading Pellets ................................................ 22 Location of Controls ......................................... 21 Manual Mode ................................................... 23 Maximum Venting Distance ............................. 11 Mobile Home Requirements ............................ 13 Opening the Door ............................................. 29 Outside Air ........................................................ 13 Packing List ........................................................ 8 Pellet Vent Termination ................................... 12 Pellet Vent Type ............................................... 12 Planning the Installation ..................................... 9 Power Outages ................................................ 27 Restrictor Adjustment ...................................... 14 Safety Notice .................................................... 21 Starting the Heater for the First Time .............. 22 Start-Up Sequence .......................................... 27 Stove Maintenance .......................................... 28 Stove Maintenance Tools ................................ 29 Stove Placement ................................................ 9 Stove Tool Storage .......................................... 29 Straight Installations ........................................ 10 Thermostat Installation .................................... 44 Troubleshooting Table ..................................... 42 Tstat Mode ....................................................... 25 Venting the Pellet Stove .................................. 11 Yearly Maintenance - Clean the Negative

Pressure Tube .............................................. 40