1.1 INTRODUCTIONThe smallest batching controller in the world.Using up to-date delta-sigma A/D converter to achieve a higher speed and higher accuracy for the batching or packing system. Built in RS232 or RS485 is selectable as standard feature(Factory preset)Multi-drop or long distance communication is possible by using RS485. Sophisticated software has provided for different batching system application.
1.2 DEFINITIONDead weight:The output voltage of the load cell in response to the weight of the platform.
Division:The ratio of step width to multiplier. The value of division can only be one of the followings: 1, 2, 5.
Excitation voltage:The voltage that supplied by the indicator to the load cell.
Final setpoint:The target weight of the material to be batched.
Free fall setpoint:When the reading of CB920X is greater than or equal to the final setpoint valueless the free fall setpoint value, the fine relay contact will be turn off.
Free fall value:The average increase in reading after the coarse and fine relay contact had to be turn off due to the free fall of work in process material.
Load cell:Load cell is a device that converts force to electronic voltage. A load cell consists of two parts. The first part is a sensor that can be linear distorted according to the force applied to it. The second part is the strain gauge element which changes its resistance according to the distortion of the sensor.
Load cell rated output:The output voltage from the load cell divided by the excitation voltage.
Maximum capacity:The maximum figure ignoring decimal point that designed to be used by the indicator.
1. DESCRIPTION
2 CB920X Instruction Manual
Multiplier:The multiplier determine the position of the decimal point or the number of tailing zero added to the internal reading.For example:If the internal reading is 234,
Multiplier Display on indicator10 23401 234.1 23.4.01 2.34.001 .234.0001 .0234
Preliminary setpoint:When the reading of CB920X is greater than or equal to the final setpoint valueless the preliminary setpoint value, the coarse output contact will be turned off.
Resolution:The ratio of the maximum capacity and division.
Span:The change of reading from the indicator in response to the change of standard weight applied.
Automatic fine setpoint correction:Fine setpoint(new)=fine setpoint(old)-[(final setpointresult material net value) /2]The correction is performed at the end of each batch process. The fine setpoint value in memory is updated after all materials are batched, and the revised fine setpoint will be used in the next time.No correction is made if fine setpoint(new)is minus.Fine setpoint (new)is set to coarse 1 if fine setpoint(new)is equal to or greaterthan coarse. Fine setpoint(new)will be set to 999 if fine setpoint(new)is greater than 999.
TDC:Time delay for discharge control. At discharge process, the discharge control will be deactivated 0.1 to 9.9 seconds after the gross weight is less than the zero band. Set range is 01to 99(i.e. 0.1 seconds to 9.9 seconds).
TTC:Time delay for tolerance check. At batching process, tolerance will be check with 0.1to 9.9 seconds delay after the fine control is deactivated. Set range is 01 to 99(i.e. 0.1seconds to 9.9 seconds).
CB920X Instruction Manual 3
1.3 FEATURES
l Double display-showing both gross and net weight simultaneously.l The smallest batching controller, panel size is only 96mm 48mm.l Weight indicator integrated with setpoint controller.l Provides complete material batching control function.l Controls up to 4 different kinds of materials.l All setpoints are keyed-in through front panel keyboard and stored in internal
memory.l All setpoints value are protected for power down.l Automatic zero tracking.l Automatically set tare by push button.l Coarse feed, fine feed and freefall compensation.l Software function setting method.l Batch report output through RS232/RS485.l Conversion rate up to 200 times/sec.l Higher accuracy of weighing scale-display resolution up to 1/15000.l RS232/RS485 input can be used to set setpoint data and system function data.l Discharge control is provided.l Tare check cycle is programmable by function setting.l Temperature coefficient is less than (0.0008% of reading +0.3 digits)/.l Optional analog output.l Optional BCD output.l Optional serial printer.l Optional CB920X software for 3 stages batching control.l Discharge control is provided.
4 CB920X Instruction Manual
2.1 GENERAL
1. Mains supply : 110VAC, 220 VAC 10%, 50/60Hz2. Power consumption : 9VA3. Operating temperature : -10 to 50 (14 to 122)4. Humidity : 90%(non-condensing)5. Line filter : Built-in
2.2 DIGITAL SECTION
1. Weight display : 7segment LED 2. LED display : Dual display for GROSS and NET weight 3. Annunciators : M1, M2, M3, M4, ZERO and MOTION 4. Negative sign indication : " " on the left most digit 5. Over-range indication : Display " " 6. Maximum capacity : 500 to 100,000 7. Step width : 1, 2, 5, 10, 20 or 50 8. Decimal point : Displays to 1, 2, 3 or 4 decimal places 9. Output capacity : open collector output 80V 0.3A (maximum)
2.3 ANALOG SECTION
1. Load cell type : All strain gauge load cells 2. Load cell supply : 10 VDC5%, 150mA maximum 3. Input sensitivity : 0.5V per division to 200V per division
4. Input impedance : 10M ohm 5. Zero point adjustment : 0.05mV to 15mV 6. Temperature coefficient : Less than (0.0008% of reading +0.3 digits)/ 7. Non-linearity : Within 0.0067% of full scale 8. A/D conversion method : Delta-Sigma 9. A/D conversion rate : Approximately 200 times/second 10. Internal resolution : 1,000,000 counts 11. Display resolution : 300 to 10,000 divisions
2. SPECIFICATION
CB920X Instruction Manual 5
2.4 RS232/RS485 SERIAL OUTPUT2.4.1 STANDARD: EIA RS232/RS485 serial output.
2.4.2 STREAM FORMAT: Data bit = 7 Parity bit = 1 (even) Stop bit = 1 Code = ASCII Code
Baud rate = 2400, 4800, 9600, 19200
2.4.3 COMMAND FOR RS232/RS485After receiving the command word from RS232/RS485 port, the indicator willcarry out the appropriate action. Those command valid for all operation mode.Output Message From CB920X
Commands Description 1. Z.TRACK T = 0 zero track delay time is off 2. Z.TRACK T = 1 zero track delay time is 1 sec 3. Z.TRACK D = 1 zero track delta band is 1 step width 4. Z.TRACK D = 2 zero track delta band is 2 step width 5. Z.TRACK D = 4 zero track delta band is 4 step width 6. MOTION 1D/S motion detection is 1 step width / sec 7. MOTION 3D/S motion detection is 3 step width / sec 8. D.P 4 multiplier is 0.0001 9. D.P 3 multiplier is 0.001 10. D.P 2 multiplier is 0.01 11. D.P 1 multiplier is 0.1 12. D.P 0 multiplier is 1 13. d 1 division is 1 14. d 2 division is 2 15. d 5 division is 5 16. MAX.CAP 500 maximum capacity is 500 17. MAX.CAP xxxxx maximum capacity is xxxxx range of xxxxx is 500 to 100000 18. MAX.CAP 100000 maximum capacity is 100000 19. BAUD 2400 baud rate is 2400 20. BAUD 4800 baud rate is 4800 21. BAUD 9600 baud rate is 9600
22. BAUD 19200 baud rate is 19200 23. Z.BAND x zero band is x%. Range of x is 1 to 10 24. UNIT kg unit is kg 25. UNIT t unit is ton 26. UNIT OFF unit off 27. CAL ZERO zero calibration is carried out
6 CB920X Instruction Manual
28. CAL SPAN span calibration carried out 29. M1 FINAL xxxxx the final set point for material 1 is xxxxx 30. M2 FINAL xxxxx the final set point for material 2 is xxxxx 31. M3 FINAL xxxxx the final set point for material 3 is xxxxx 32. M4 FINAL xxxxx the final set point for material 4 is xxxxx
33. M1 COARSE xxxx the coarse set point for material 1 is xxxx 34. M2 COARSE xxxx the coarse set point for material 2 is xxxx 35. M3 COARSE xxxx the coarse set point for material 3 is xxxx 36. M4 COARSE xxxx the coarse set point for material 4 is xxxx 37. M1 FINE xxx the fine set point for material 1 is xxx 38. M2 FINE xxx the fine set point for material 2 is xxx 39. M3 FINE xxx the fine set point for material 3 is xxx 40. M4 FINE xxx the fine set point for material 4 is xxx 41. YES no error occur or confirm true 42. NO incorrect command received or confirm false
command 43. ERROR x error number x occurs during calibration 44. TARE xxxx send the value of tare.(xxxx is the current tare weight,
yyyy yyyy is the tare weight for batching) 45. ZERO xxxx send the zero correction value x step width 46. OL, NT, +0123.45kg, Reply to read inquiry CRLF OL = overload ST = stable US = unstable NT = net weight GS = gross weight CRLF = advance to the next line
47. RLY 1 Output of material1 is activated by RLY command 48. RLY D Output of discharge control is activated by RLY 49. TOL 3 tolerance range is 0.3% 50. ZERO x percentage of zero return range is x 51. TOL xx percentage of out of tolerance range is xx 52. TTC xx Time delay for tolerance check 53. TDC xx Time delay for discharge control 54. BCD xx BCD output rate 55. CIT xx Compare inhabit time (No. of batch interval) 56. FILTER xx Digital filtering 57. SDT xx Start delay time 58. EFF xx Enable free fall compensation 59. ETC xx Enable tolerance check 60. ATE xx Automatic tare enable
Input Commands To CB920X: Commands Description 1. FUNC Set CB920X to function setting mode.
2. CAL Set CB920X to calibration mode.
CB920X Instruction Manual 7
3. SET Set CB920X to setpoint setting mode 4. READ Request measured data 5. TARE What is the value of tare 6. TARE ON Set tare 7. TARE OFF Reset tare 8. ZERO What is the value of the zero offset value 9. ZERO ON Set zero offset 10. ZERO OFF Reset zero offset 11. PROG Set RS232/RS485 operation mode as command mode 12. AUTO Set RS232/RS485 operation mode as automatic mode 13. CONT Set RS232/RS485 operation mode as continuous mode 14. RLY Which output is activated by RLY command 15. RLY 1 Activate output for material 1 (output can be activated only when CB920X is in normal weighing mode. 1,2,3,4 represent the output for corresponding material No.
C for coarse output, F for fine output, D for discharge output, T for out of tolerance) 16. RLF OFF Turn off any output that turned on by RLY command 17. ABO Abort production 18. ST Start production
19. KEY ON Key protection on (key function inhibit)20. KEY OFF Key protection off (key function enable)21.DSEL AUTO Auto mode is being used 22.DSEL GROSS Gross mode is being used23.DSEL NET Net mode is being used
NOTE: All command must be ended with , e.g. READ command is "52, 45, 41, 44, 0D, 0A" in ASCII code.
BATCH REPORT FROM CB920X: Note 1: The material net value of each material is stored, then it is simultaneously output only once after the final material net captured.
NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Note2: That material is not output when zero is set to the final value.
M
M
M
M
1
2
4
3
,
,
,
,
N
N
N
N
T
T
T
T
,
,
,
,
+
+
+
+
1
2
1
1
9
0
5
0
.
.
.
.
9
0
0
0
9
0
0
0
k
k
k
k
g
g
g
g
LF
LF
LF
LF
CR
CR
CR
CR
8 CB920X Instruction Manual
OPERATING MODE FOR RS232/RS485:(a) Command Mode(PRO):
After all materials is batched, a "ENQ" message will send out through RS232/RS485. When "ACK" command is received by CB920X, the batch reportwill send out through RS232/RS485. There is no report sending out if start command is activated before "ACK" command is received.
The No. of times of report output is not limited, the report will be cleared when next production is started.
(b) Continuous Mode(CONT):Weighing data will be transferred continuously without any input command to
the RS232/RS485 port. Besides, batch report will send automatically afterbatching is completed.
(c) Automatic Mode(AUTO): A "READ" command is required for reading weighing data from CB920X. However, the batching report will send automatically after batching is completed.
2.4.4 DATA FORMAT:
CR LF STATUS1 STATUS2 WEIGHING DATA UNIT
STATUS1: M1 material 1 M2 material 2
M3 material 3M4 material 4
STATUS2: NT = net weightGS = gross weightAB = abort
WEIGHING DATA: An eight bits stream consists of "0" to "9", negative sign "-", positive sign "+", space " " and decimal point.
UNIT: kg = kilogram t = ton
CB920X Instruction Manual 9
2.4.5 SCHEMATIC DIAGRAM FOR THE OUTPUT PORT
CB920X RS232/RS485 OUTPUT/INPUT
TXD TXD(+)
RXD RXD(-)
COM
2.4.6 OUTPUT SETTING Baud Rate:
2400 Baud 4800 Baud
9600 Baud 19200 Baud
Mode of Operation: Continuous mode Command mode Automatic mode
2.4.7 PIN DESCRIPTION RS232 Connector
PHOTO OUTPUT RS232
Pin Signal descriptionRXD Data receive input TXD Data transmit outputCOM Ground
MA
TER
IAL
1
MA
TER
IAL
2
MA
TER
IAL
3
MA
TER
IAL
4
CO
AR
SE
FIN
E
DIS
CH
AR
GE
TOLE
RA
NC
E
EMTR
CO
M
TXD
RX
D
CO
M
+ CO
M
OPT
ION
AN
ALO
GO
UT
10 CB920X Instruction Manual
3.1 GENERAL RULES Do not install the CB920X in direct sunshine, and avoid sudden temperature changes, vibration, or wind. Best performance is achieved when temperature is about 20/68 and the relative humidity is about 50%.
Ground the CB920X via the power cable to the rear terminal and ensure a good ground connection. Do not ground directly to other equipment. Analog input/output signals are sensitive to electrical noise. Do not bind these cables together as it could result in cross-talk interference. Please also keep them well away from AC power cable, and keep all cable/coax as short as possible.
If the local AC electrical supply fluctuates by more than 10% an AC regulator must be used in order to stabilize the power supply and reduce power spikes.
3.2 INPUT SENSITIVITY OF LOAD CELL
The input sensitivity (A) of load cell can be calculated from the following formula.
A = [Load cell output voltage at scale capacity-Load cell output voltage at dead load] Step width / Scale capacity
CB920X requires that "A" must be greater than or equal to 0.5V per division.
3.3 CONNECTING THE LOAD CELL TO THE INDICATOR
The analog output from the Load Cell and the RS232 input/output signals are sensitive to electrical noise. Do not bind these cables together as it could result incross-talk interference. Please also keep them well away from the AC power cables.
3. OPERATION
CB920X Instruction Manual 11
LOAD CELL CONNECTIONSPin no. Signal
EXC+EXC-SIG+SIG-SHD
Excitation +Excitation -Signal +Signal -Shield
SIG+ SIG- EXC+ EXC- SHDSIG+SIG-
EXC-
EXC+
SHD
12 CB920X Instruction Manual
3.4 FRONT PANEL DESCRIPTION
FRONT PANEL
5
12
3
4
6
7 8 9 10
1. M1 annunciator : Indicates material 1 in process.2. M2 annunciator : Indicates material 2 in process.3. M3 annunciator : Indicates material 3 in process.4. M4 annunciator : Indicates material 4 in process.5. ZERO annunciator : Indicates zero.6. MOTION annunciator : Indicates motion detection.7. ENTER button : Accepts data entry.8. MODE button : Selects the function setting mode.9. TARE button : If motion is not being detected and discharge
relay is in off state, the tare weight will be memorized and the indicator displays zero.This button charges the display mode to NETmode.
10. ZERO button : If the offset from the initially calibrated zero is within 1% to 10% (refer to Function setting) of the
maximum capacity and no motion is being detected, the indicator will display zero weightby pressing this key.
CB920X BATCHING CONTROLLER
ENTER MODE TARE ZERO
MOTION
ZERO
M1
M2
M3
M4
CB920X Instruction Manual 13
3.5 REAR PANEL DESCRIPTION
3.5.1 REAR PANEL
CB920X
CB920XA
M 1
M 2
M 3
M 4
CO
AR
SE
FIN
E
DIS
CH
AR
GE
TOLE
RA
NC
E
EMTR
CO
M
TXD
(+)
RX
D (-
)
CO
M
+ CO
M
SIG
+
SIG
-
EXC
+
EXC
-
SHIE
LD
STA
RT
CO
M
EAR
TH AC
AC
M 1
M 2
M 3
MED
IUM
CO
AR
SE
FIN
E
DIS
CH
AR
GE
TOLE
RA
NC
E
EMTR
CO
M
TXD
(+)
RX
D (-
)
CO
M
+ CO
M
SIG
+
SIG
-
EXC
+
EXC
-
SHIE
LD
STA
RT
CO
M
EAR
TH AC
AC
14 CB920X Instruction Manual
CB920X
DIODE
POWER
SUPPLY6V/12V/+24V
3.5.2 CONNECTION FOR CONTROL OUTPUT
CONNECTION ID SIGNALM1 Material 1 outputM2 Material 2 outputM3 Material 3 outputM4 (MEDIUM) Material 4 output(Medium output)COARSE Coarse outputFINE Fine outputDISCHARGE Discharge outputTOLERANGE Out of tolerance outputEMTR COM CommonTXD RS232/RS485 transmission outputRXD RS232/RS485 receive inputCOM Digital Ground+ Analog output voltage (option)COM Analog Ground
SIG+ Load cell signal +SIG- Load cell signal -EXC+ Load cell excitation +EXC- Load cell excitation -SHIELD Shielding for load cellSTART Production start activateCOM Start comEARTH Electric earthAC AC input AC AC input
The output capacity is 5V to 24V open collector and the max. current is 0.3A. DC operated buffer relay should be used to isolate CB920X from external controlled devices in order to reduce interference. Diode should be connected in parallel with the coil DC operated buffer relay to suppress any spark noise caused by contact switching.
BUFFER RELAY GND
CB920X Instruction Manual 15
The production
start button
M1
EMTR COM.GND
M1 Material 1
M2 Material 2
M3 Material 3
M4 Material 4(Medium)
Coarse
Fine
Discharge
Tolerance
START
COM
The production start button should be momentary switch and production is initiated immediately. When the button is pushed and then released. The
material contacts (M1 to M4) in CB920X are actuated one by one according to the setpoint entered.
6/12/24V POWER SUPPLY
M2
M3
M4 (MEDIUM)
COARSE
FINE
DISCHARGE
TOLERANCE
16 CB920X Instruction Manual
M3
M4
M1
M2
M3
M4
+24V
M1 Coarse
M2 Coarse
M3 Coarse
M4 Coarse
M1 Fine
M2 Fine
M3 Fine
M4 Fine
COARSE
The coarse and fine batching control can be implemented by the following relay logic.
FINE
In all circumstances, the buffer relays should be DC Operated and make sure thatthe contact rating of buffer relays is adequate to drive the corresponding starter orpower controlling device. Diode suppressor should be connected in parallel with the coil of every DC operated buffer relay.
If AC operated relay is needed, RC suppressor should be connected in parallel with therelay coil. It also applies to those controlling device that is inductive in nature. (E.G. solenoid valve).
24V POWER SUPPLY
M1
M2
CB920X Instruction Manual 17
CB920X
CB920X
3.6 FUNCTION SETTING
keyIn function setting process, this key is used to select the digit to be modified. The decimal point of the selected digit will be flashing.
keyIn function setting process, this key is used to change the value of the digit selected.
keyIn function setting process, the user should press to select the next function for setting
keyIn function setting, this key is used to store the data entry for each function setting, and return to normal weighing condition.
3.6.1 START THE FUNCTION SETTING PROCESSPress and hold key, then press the key without releasing the
key. The indicator display , and now set the parameters.
Before changing any of the parameters below, pressing the key and return to the weighing mode.
If multiplier, maximum capacity or division has been changed, the indicator will first check any error occurs before accepting the key.
If the division or multiplier is changed, the indicator will displayed " " and calibration must be carried out.
ZERO
ENTER
MODE
ENTER
TARE
MODE
ENTER
ENTER MODE
ENTER
ENTER
ENTER
18 CB920X Instruction Manual
CB920X
CB920X
CB920X
3.6.2 ZERO TRACKING FUNCTIONTwo parameters are required to define the zero track function. The first one is the zerotrack delta band, and the second one is the zero track delay time. When the ZERO keyis being pressed, the reading will be tracked to zero if the weight is within the zero track delta band for a time interval greater than or equal to the zero delay time.
3.6.3 ZERO TRACK DELAY TIME
While is being displayed, select 0.5, 1.0, 1.5, 2.0 or off.0.5~2.0 = 0.5 to 2.0 sec delay time
off = No zero track
Press MODE key to go to the next step.
3.6.4 ZERO TRACK DELAY BAND
While is being displayed, select 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5 or 5.0.
0.5~5.0 = 0.5 to 5.0 step width
Press MODE key to go to the next step.
TARE
MODE
TARE
MODE
CB920X Instruction Manual 19
CB920X
CB920X
CB920X
3.6.5 MOTION DETECTION TIME
While is being displayed, select 1, 2 or off.1 = 1 sec2 = 2 sec
off = No motion detection
Press MODE key to go to the next step.
3.6.6 MOTION DETECTION BAND
While is being displayed, select 1, 2, 5 or 10.1 = 1 step width/sec
The motion annunciator will illuminate as long as the reading changes by 1 stepwidth within 1 to 2 sec.
2 = 2 step width/secThe motion annunciator will illuminate as long as the reading changes by 2 step width within 1 to 2 sec.
5 = 5 step width/secThe motion annunciator will illuminate as long as the reading changes by 5 step width within 1 to 2 sec .
10 = 10 step width/sec The motion annunciator will illuminate as long as the reading changes by 10 step
width within 1 to 2 sec.
TARE
TARE
MODE
20 CB920X Instruction Manual
CB920X
CB920X
CB920X
CB920X
Press MODE key to go to the next step.
3.6.7 MULTIPLER OR DECIMAL POINT
While is being displayed, select 0 to 4.Display format Multiplier
10
1
0.1
0.01
0.001
0.0001
Press MODE key to go to the next step.
3.6.8 DIVISION
While is being displayed, select 1, 2 or 5.Step width = division multiplier
MODE
TARE
MODE
TARE
CB920X Instruction Manual 21
CB920X
CB920X
CB920X
Press MODE key to go to the next step.
3.6.9 MAXIMUM CAPACITY
While is being displayed, select the range 500 to 100,000.
Press MODE key to go to the next step.
3.6.10 RESOLUTION The maximum resolution is 1/15000 and the minimum resolution is 1/300. Setting
outside the maximum and minimum resolution range is invalid and must be avoided.
Resolution = Step width / Maximum capacity
Note: The resolution can never exceed 1/15000.
MODE
TARE
MODE
22 CB920X Instruction Manual
Step Width
Max Capacity1 2 5 10 20 50
500 1/500
1000 1/1000 1/500
1200 1/1200 1/600
1500 1/1500 1/750 1/300
2000 1/2000 1/1000 1/400
2500 1/2500 1/1250 1/500
3000 1/3000 1/1500 1/600 1/300
4000 1/4000 1/2000 1/800 1/400
5000 1/5000 1/2500 1/1000 1/500
6000 1/6000 1/3000 1/1200 1/600 1/300
8000 1/8000 1/4000 1/1600 1/800 1/400
10000 1/10000 1/5000 1/2000 1/1000 1/500
12000 1/12000 1/6000 1/2400 1/1200 1/600
15000 1/15000 1/7500 1/3000 1/1500 1/750 1/300
20000 1/10000 1/4000 1/2000 1/1000 1/400
25000 1/12500 1/5000 1/2500 1/1250 1/500
30000 1/15000 1/6000 1/3000 1/1500 1/600
40000 1/8000 1/4000 1/2000 1/800
50000 1/10000 1/5000 1/2500 1/1000
60000 1/12000 1/6000 1/3000 1/1200
80000 1/8000 1/4000 1/1600
100000 1/10000 1/5000 1/2000
CB920X Instruction Manual 23
CB920X
CB920X
CB920X
CB920X
3.6.11 BAUD RATE RS232/RS485
While is being displayed, select 240048009600 or 19200 baud.
Press MODE key to go to the next step.
3.6.12 ZERO BAND
While is being displayed, select the range 0.1 to 10, 1 to 100 represent0.1% to 10% of the zero band. If the final weight is 100kg and zero band is set to 1%, the discharge signal will be deactivated when the gross weight is less then 1% of the final weight.
Press MODE key to go to the next step.
TARE
MODE
TARE
MODE
24 CB920X Instruction Manual
CB920X
CB920X
3.6.13 OPERATING MODE OF RS232/RS485
While is being displayed, select the operating mode of RS232/RS485.
: Continuous modeWeighing data will be sent without any command input. After batching is completed, the batching report will be sent also without any command.
: Program ModeAfter receiving a read command, CB920X send out the weighing data. After batching is completed,CB920X send out a ENQ (i.e. 05 in ASCII code). If ACK command is received before next production is activated , then CB920X send out the batching report .The No. of times of report output is not limited, the report will becleared when next production is started.
: Automatic ModeAfter receiving a READ command, CB920X send out the weighingdata.After batching is completed, CB920X send out the batching report without any command input.
Press MODE key to go to the next step.
MODE
MODE
CB920X Instruction Manual 25
CB920X
CB920X
CB920X
CB920X
CB920X
3.6.14 UNIT
While is being displayed, select kgt or OFF. = kg
= t = OFF
Press MODE key to go to the next step.
3.6.15 Press key, enter the second level of function setting.
3.6.16 ZERO RETURN RANGE
While is being displayed, select the range of 1% to 10%.The maximum percentage of zero shift which can suppressed to zero by pressing the key.
Press MODE key to go to the next step.
TARE
MODE
TARE
ZERO
ZERO
ZERO
ZERO
26 CB920X Instruction Manual
CB920X
CB920X
CB920X
CB920X
3.6.17 TOLERANCE RANGE
While is being displayed, select the range of 0.1% to 9.9%. It is the percentage of the final weight.
Press MODE key to go to the next step.
3.6.18 TIME DELAY FOR DISCHARGE CONTROL
While is being displayed, select the range of 0.1s to 9.9s. It is the time delayFor discharge control, in discharge process the discharge control will be deactivateafter the gross weight is less than the zero band and a time delay is passed.
Press MODE key to go to the next step.
Weight
Time
Start
Fine
Free Fall
Tolerance Check
Discharge
Tolerance range
Start
Discharge
Weight
Time
Zero band
tdc
TARE
MODE
TARE
MODE
Fine
Free Fall
Tolerance Check
CB920X Instruction Manual 27
CB920XCB920X
CB920X
CB920X
CB920X
3.6.19 TIME DELAY FOR TOLERANCE CHECK
While is being displayed, select the range of 0.1s to 9.9s. It is the timedelay for tolerance check. The tolerance will be checked only when a valid Enabletolerance check and time delay is passed.
Press MODE key to go to the next step.
3.6.20 COMPARISION INHIBIT TIME (ONLY FOR COARSE CONTROL)
Press TARE key, select the range of 0.1s to 9.9s.
When the feed gate is open or closed, the weight displayed will be very a lot. It is caused by the unstable weighing hopper, specially when the dead weight of the weighting hopper is very small. An invalid control may be caused due to this unstable variation. The comparison inhabit time will result a better accuracy and stability.
Press MODE key to go to the next step.
Weight
Timettc
TARE
Start
Coarse control is deactivated
Weight
TimeCIT.C
MODE
TARE
MODE
StartDischarge
Fine
Free Fall
Tolerance Check
28 CB920X Instruction Manual
CB920XCB920XCB920X
SIG+ SIG-EXC+ EXC- SHD
CB920X
CB920XCB920X
CB920XCB920X
3.6.21 COMPARISION INHIBIT TIME (ONLY FOR FINE CONTROL)
Press TARE key, select the range of 0.1s to 9.9s.
Press MODE key to go to the next step.
3.6.22 DIGITAL FILTERING
While is being displayed, select 0, 2, 4, 8, 16, 32, 64,128 or 256. The weighting hopper may be vibrated due to its resonant frequency and external vibration. This may cause the indication to show an unstable reading. If system is very a lot, select the higher rank, otherwise select the lower rank.
Press MODE key to go to the next step.
More Sensible
Less Sensible
0
256
MODE
TARE
Weight
TimeCIT.F
TARE
MODE
Start
Coarse control is deactivated
CB920X Instruction Manual 29
CB920XCB920XCB920X
SIG+ SIG-EXC+EXC- SHD
CB920XCB920XCB920X
SIG+ SIG-EXC+ EXC- SHD
CB920XCB920XCB920X
SIG+ SIG-EXC+ EXC- SHD
CB920XCB920XCB920X
SIG+ SIG-EXC+ EXC- SHD
3.6.23 THE SECOND STAGE DIGITAL FILTERING
Press TARE key to select 0 or 1.0 = invalid1 = valid
Press MODE key to go to the next step.
3.6.24 THE SECOND STAGE DIGITAL FILTER RANGE
Press TARE key to select 1 to 99.Activate the second stage digital filter when motion detection is within the range of digital filter, otherwise deactivate the second stage digital filter.Note: The setting is valid only when the second stage digital filter is valid, otherwise
skip to the next step.
Press MODE key to go to the next step.
MODE
TARE
TARE
MODE
30 CB920X Instruction Manual
CB920XCB920XCB920X
SIG+ SIG-EXC+ EXC- SHD
CB920XCB920XCB920X
SIG+ SIG-EXC+ EXC- SHD
Batch No.
EFF=0
EFF=1
EFF=3
1 2 3 4 5 6
CB920XCB920XCB920X
SIG+ SIG-EXC+ EXC- SHD
CB920XCB920XCB920X
SIG+ SIG-EXC+ EXC- SHD
3.6.25 START DELAY TIME
While is being displayed, select the range of 0.0s to 9.9s. It is the time difference between the start input and actual batching process. When the discharge gate is closed, it may cause the weighing hopper to be vibrated. The start delay timeis used to ensure that the discharge gate is closed and the weighing hopper is stable.
Press MODE key to go to the next step.
3.6.26 ENABLE FREE-FALL COMPENSATION
While is being displayed, select the range of 0 to 99.
0 = No Free Fall compensation is allowed.1 ~99 = Free Fall compensation will be carried out on every 1 to 99 times of
batching.
Press MODE key to go to the next step.
Weight
Timesdt
MODE
TARE
MODE
MODEStart
Discharge
Fine
Free Fall
Tolerance Check
CB920X Instruction Manual 31
Batch No.
Etc=0
Etc=1
Etc=3
1 2 3 4 5 6CB920XCB920XCB920X
SIG+ SIG-EXC+ EXC- SHD
CB920XCB920XCB920X
SIG+ SIG-EXC+ EXC- SHD
CB920X
CB920X
3.6.27 ENABLE TOLERANCE CHECK
While key is being displayed, select 0 to 99. 0 = No tolerance check is allowed
1 ~99 = Tolerance check will be carried out on every 1 to 99 times of batching.
Press MODE key to go to the next step.
3.6.28 BCD OUTPUT RATE
While is being displayed, select the BCD output rate of 15/sec50/sec100/sec or 200/sec.
Press MODE key to go to the next step.
TARE
MODE
MODE
TARE
32 CB920X Instruction Manual
CB920X
CB920X
CB920X
CB920X
3.6.29 AUTOMATICC TARE ENABLE
If ATE=0, CB920X will use the tare value of the first production as the tare value of all other production until power down.If ATE=1~99, the tare value will be updated for every 1~99times of production.
3.6.30 Press ZERO key, enter the three level function setting.
3.6.31 AUTOMATIC ZERO RETURN
While is being displayed, Select 0 or 1.0 = Disable nothing is done1 = Enable
Press MODE key to go to the next step.
TARE
ZERO
TARE
MODE
CB920X Instruction Manual 33
CB920X
CB920X
3.6.32 START TARE OPERATION
Press TARE key to select 0 or 1. 0 = Tare is not carried out at the first batch when power on 1 = Tare is carried out at the first batch when power on The following table shows the relationship for ATE and STO.
STO=0, ATE=1 STO=0, ATE=2 STO=1, ATE=2BATCH TARE BATCH TARE BATCH TARE1st times No 1st times No 1st times Yes2nd times Yes 2nd times No 2nd times No3rd times Yes 3rd times Yes 3rd times Yes4th times Yes 4th times No 4th times No5th times Yes 5th times Yes 5th times Yes6th times Yes 6th times No 6th times NoEnd of batch cycle.Restart operation when power is not turned off.
End of batch cycle.Restart operation when power is not turned off.
End of batch cycle.Restart operation when power is not turned off.
BATCH TARE BATCH TARE BATCH TARE1st times Yes 1st times Yes 1st times Yes2nd times Yes 2nd times No 2nd times No3rd times Yes 3rd times Yes 3rd times Yes
STO=1, ATE=0BATCH TARE1st times Yes2nd times No3rd times No
If STO and ATE are equal to 0, then the tare weight is equal to 0 and the tare operation is not carried out.
Press MODE key to go to the next step.
TARE
MODE
34 CB920X Instruction Manual
CB920X
CB920X
CB920X
CB920X
3.6.33 START CONDITION
While displaying , select 0 , 1, 2 or 3 to start production.0 = All times besides batchingsetpointfunction settingcalibration1 = Net within zero range2 = Gross within zero range3 = Gross within zero range and no production
Press MODE key to go to the next step.
3.6.34 AUTO TARE CONDITION
While displaying , select 0 or 1.0 = Executed regardless of the value1 = Tare executed at GROSS Weigh Zero range.
Press MODE key to go to the next step.
TARE
MODE
TARE
MODE
CB920X Instruction Manual 35
CB920X
CB920X
3.6.35 TIME DELAY FOR TARE
Press TARE key to select 0.0 to 9.9.0 = No delay time for tare
0.1~9.9 = The delay time for tare is 0.1~9.9 secNote: When ATE is effective, set the delay time for tare to ensure the tare operation
is in stable status. The TDT parameter will be invalid if no tare is accepted.
Press MODE key to go to the next step.
TARE
MODE
Start
Internal tare operation (ATE is valid)
TDT
Internal tare operation(ATE is invalid)
36 CB920X Instruction Manual
CB920X
CB920X
3.6.36 TARE CHECK COUNTER
Press TARE key to select 1 to 99. 1 = No average2~99 = Number of sample for tare check operationDuring batching procedure, the tare value is the average value of number of tare value selected at the tare operation.In normal weighing mode, press TARE key or received a TARE command from RS232/RS485 interface, the tare value will not be averaged.
Press MODE key to go to the next step.
TARE
MODE
CB920X Instruction Manual 37
CB920X
CB920X
3.6.37 FINE CONTROL DELAY
Press TARE key to select 0 to 100.0 = No delay, coarse and fine output are turned on simultaneously
1~99 = At net value (final value coarse value) FCD / 100 100 = Fine output is turned on when coarse output is completed
Note: This parameter is not effective at re-batch process.
Press MODE key to go to the next step.
TARE
MODE
COARSE
FINE
Max. delay time
Final value Coarse value
FCD
38 CB920X Instruction Manual
CB920X
CB920X
3.6.38 FINE DELAY TIME
Press TARE key to select 0.0 to 9.9.(1) When the coarse output is turned on and fine control delay time is passed, the fine
output will be turned on after delay a period of time(FDT).This parameter is not effective at re-batch process.
(2) Fine control delay is completed after the coarse output is turned off.(FCD=100).i) FDT is still valid when dribble control is not effective.ii) FDT will be set to 0 when dribble control is effective.
Press MODE key to go to the next step.
TARE
MODE
COARSE
FINEFCD
FDT
COARSE
FINE(no dribble
control)
FCD FDT
FINE(dribble control)
CB920X Instruction Manual 39
CB920X
CB920X
CB920X
3.6.39 DRIBBLE BATCH CONTROL(ON TIMER FOR FINE CONTROL)
Press TARE key to select 0.0 to 9.9.0.0 = No dribble batch control
0.1~9.9 = The dribble control ON time is 0.1~9.9 seconds.
Press MODE key to go to the next step.
3.6.40 DRIBBLE BATCH CONTROL(OFF TIMER FOR FINE CONTROL)
Press TARE key to select 0.0 to 9.9.0.0 = No dribble batch control
0.1~9.9 = The dribble control OFF time is 0.1~9.9 seconds.
The dribble control is invalid if the net value (final value fine value).
TARE
MODE
TARE
COARSE
FINE
driOFF driON
40 CB920X Instruction Manual
CB920X
CB920X
CB920X
The dribble control will be activated after the coarse feed is turned off.The dribble control will be activated when the net value is within final value less coarse value and tolerance range. The dribble control will be deactivated at re-batch.
Press MODE key to go to the next step.
3.6.41 COMPARISON CHECK COUNTER
Press TARE key to select 1 to 99.1 = Compare the net value displayed with the current value
2~99 = Number of sample for setpoint comparison is 2 to 99The net value will be averaged when the net value is more than and equal to (coarse value / coarse comparison), then compare this average value with thecoarse / fine value .The coarse/fine output will be turned off when the average net value is more than and equal to the coarse / fine value. Note: This parameter will be invalid during the comparison inhibit time.
Press MODE key to go to the next step.
TARE
TARE
MODE
CB920X Instruction Manual 41
CB920X
CB920X
CB920X
CB920X
3.6.42 FREE FALL COMPENSATION RANGE
Press TARE key to select 0 to 999.0 = The free fall compensation will be carried out automatically regardless the
net value1~999 = The free fall compensation will be carried out automatically if the value is
within the free fall compensation range.If the absolute value of the Final less net value is within the free fall compensation range, the fine setpoint compensation will be carried out automatically. When the fine control is deactivated, the net compensation will be carried out.When EFF is equal to 1~xx, it means the free fall compensation will be carried out every 1 or xx times.
Press MODE key to go to the next step.
3.6.43 DELAY HOLD TIME
Press key to select 0.0 to 9.9.0.0 = No hold function
0.1~9.9 = 0.1 to 9.9 sec(net weight hold time)
Press MODE key to go to the next step.
TARE
MODE
TARE
MODE
42 CB920X Instruction Manual
CB920X
CB920X
CB920X
CB920X
3.6.44 MATERIAL RE-BATCH
Press key to select 0 or 1.0 = Disable1 = Enable
Press MODE key to go to the next step.
3.6.45 ID CODE
Press TARE key to select 00 to 99.For 00, RS485 does not use the ID code, the commands can be executed at anytime without acknowledge of ID code.Note: This parameter is valid only when the RS485 interface is selected.
3.6.46 RETURN TO NORMAL WEIGHING CONTROL
Press key to return to normal weighing condition.Note: When maximum capacity, division or multiplier is changed, the system must
calibration again. The gross display of CB920X will show and waiting for a calibration command. After calibration is performed, set setpoint function is required. The gross display will show and waiting for setting command.
ENTER
TARE
TARE
MODE
ENTER
CB920X Instruction Manual 43
CB920XCB920XCB920X
SIG+ SIG-EXC+ EXC- SHD
3.7 FUNCTION SETTING BY RS232/RS485At normal weighing condition, input a command FUNC , The gross display will show .
Command Input CB920X ResponseFUNC
3.7.1 ZERO TRACK DELAY TIMEZ.TRACK T=0
Select 0,5,10,15 or 20 5 Z.TRACK T=0.5
Input N for next settingN
3.7.2 ZERO TRACK DELAY BANDZ.TRACK D=1.0
Select 5,10,15,20,25,30,35,40,45 or 5040 Z.TRACK D=4.0
Input N for next function settingN
3.7.3 MOTION DETECTION TIMEMOTION T=0
Select 0, 1or 2 step width1 MOTION T=1
Input N for next function settingN
3.7.4 MOTION DETECTION RANGEMOTION D=1
Select 1, 2, 5 or 10 step width5 MOTION D=5
Input N for next function settingN
44 CB920X Instruction Manual
3.7.5 DECIMAL POINTD.P 4
Select 0, 1, 2, 3 or 4 0 = No decimal point1 = XXXX.X2 = XXX.XX3 = XX.XXX4 = X.XXXX D.P 0
Input N for next settingN
3.7.6 MULTIPLIER (It is possible to modify the multiplier only when no decimal point is set)
MULT 1Select 1 or 10
10 MULT 10Input N for next setting
N
3.7.7 DIVISIONd 1
Select 1, 2 or 55 d 5
Input N for next settingN
3.7.8 MAXIMUM CAPACITYMAX.CAP 500
Select 500 to 100,000.3500 NO ?100000 MAX.CAP 100000
Input N for next settingN
If there is any error in the maximum capacity, step width and multiplier, error massage Error 1 will be sent out. CB920X will return to step 3.7.5.
3.7.9 BAUD RATE OF RS232/RS485BAUD 2400
Select 2400, 4800, 9600 or 192009600 BAUD 9600
Input N for next settingN
3.7.10 ZERO BANDZ.BAND 5
Select 1 to 1007 Z.BAND 0.7
Input N for next settingN
CB920X Instruction Manual 45
3.7.11 UNITUNIT kg
Select kg, t or OFFt UNIT t
kg UNIT kg OFF UNIT OFF
Input R to exit the setting R YES
Input J enter the second level setting
3.7.12 ZERO RETURN RANGEZ.RANGE 2
Select 1 to 10 5 Z.RANGE 5Input N for next setting
N
3.7.13 TOLERANCE RANGETOL RANGE 0.5
Select 1 to 9999 TOL RANGE 9.9
Input N for next settingN
3.7.14 TIME DELAY FOR DISCHANGE CONTROLTDC 0.5
Select 1 to 9999 TDC 9.9
Input N for next settingN
3.7.15 TIME DELAY FOR TOLT TIMETTC 0.5
Select 1 to 9950 TTC 5.0
Input N for next settingN
46 CB920X Instruction Manual
3.7.16 COMPARISON INHIBIT TIME(ONLY FOR COARSE CONTROL)CIT.C 9.9
Select 1 to 9950 CIT.C 5.0
Input N for next settingN
3.7.17 COMPARISON INHIBIT TIME(ONLY FOR FINE CONTROL)CIT. M 9.9
Select 1 to 995 CIT. M 0.5
Input N for next settingN
3.7.18 DIGITAL FILTERINGD.FILTER 256
Input 0 to 2560 D.FILTER 0
Input N for next settingN
3.7.19 THE SECOND STAGE DIGITAL FILTERING2.D.F. 0
Select 0 or 11 2.D.F. 1
Input N for next settingN
3.7.20 THE SECOND STAGE DIGITAL FILTER RANGED.F.R 0
Select 0 to 9910 D.F.R 10
Input N for next settingN
3.7.21 START DELAY TIMESDT 0.0
Select 0 to 9950 SDT 5.0
Input N for next settingN
CB920X Instruction Manual 47
3.7.22 ENABLE FREE FALL COMPENSATIONEFF 50
Select 0 to 990 EFF 0
Input N for next settingN
3.7.23 ENABLE TOLERANCE CHECKETC 0
Select 0 to 9950 ETC 50
Input N for next settingN
3.7.24 BCD OUTPUT RATEBCD RATE 15
Select 15, 50 100 or 20050 BCD RATE 50
Input N for next settingNBCD
3.7.25 AUTOMATIC TARE ENABLEATE 0
Select 0 to 9999 ATE 99
Input R to return to the normal weighing mode.R YES
Input J to enter the third level setting mode.J
3.7.26 AUTOMATIC ZERO RETURNAZR 0
Select 0 or 11 AZR 1
Input N for next settingN
3.7.27 START TARE OPERATIONSTO 0
Input 0 or 11 STO 1
Input N for next settingN
48 CB920X Instruction Manual
3.7.28 START CONDITIONSTC 0
Select 0, 1, 2 or 33 STC 3
Input N for next settingN
3.7.29 AUTO TARE CONDITIONATC 0
Select 0 or 11 ATC 1
Input N for next settingN
3.7.30 TIME DELAY FOR TARETDT 0
Select 0 to 9950 TDT 5.0
Input N for next settingN
3.7.31 TARE CHECK COUNTERTCC 50
Select 1 to 991 TCC 1
Input N for next settingN
3.7.32 FINE CONTROL DELAY FCD 0
Select 0 to 10060 FCD 60
Input N for next settingN
3.7.33 FINE DELAY TIMERFDT 9.9
Select 0 to 9950 FDT 5.0
Input N for next settingN
CB920X Instruction Manual 49
3.7.34 DRIBBLE BATCHING CONTROL(ON )DRI.ON 0.0
Select 0 to 9999 DRI.ON 9.9
Input N for next settingN
3.7.35 DRIBBLE BATCHING CONTROL(OFF)DRI.OFF 0.0
Select 0 to 9999 DRI.OFF 9.9
Input N for next settingN
3.7.36 COMPARISON CHECK COUNTERCCC 99
Select 1 to 991 CCC 1
Input N for next settingN
3.7.37 FREE FALL COMPENSATION RANGEFFR 50
Select 0 to 25610 FFR 0
Input N for next settingN
3.7.38 DELAY HOLD TIMEDHT 9.9
Select 0 to 9950 DHT 5.0
Input N for next settingN
3.7.39 MATERIAL RE-BATCHREb 0
Select 0 or 10 REb 1
Input N for next settingN
50 CB920X Instruction Manual
CB920X
CB920X
3.7.40 ID CODE(ONLY WHEN RS485 IS SELECTED)ID.NO. 1~99
Select 00 to 995 ID.NO. 5
Input R to return to the normal settingR YES
Note: When maximum capacity, division or multiplier is changed, system must calibrate again. The gross display of CB920X will show and waiting
for a calibration command. After calibration is performed, set setpoint function is required. The gross display will show and waiting for setting command.
3.8 CALIBRATION
Calibration should be carried out during the initial installation of CB920X, or any parts of the complete weighing system is changed or any drift is noted.Note: Zero tracking can not be performed at calibration.
3.8.1 PREPARATIONFunction setting should first be set as required.
3.8.2 START THE CALIBRATION PROCESSPress and hold the key, Press the key without releasing the key.The indicator displays for 2 sec.
3.8.3 ZERO CALIBRATIONZERO CALIBRATION 1
If there is not necessary to calibrate the zero offset, press key to skip the zero calibration procedure, enter the next setting.
ENTER
TARE
TARE
ENTER TARE
TARE
ENTER
CB920X Instruction Manual 51
CB920X
CB920X
CB920X
CB920X
ZERO CALIBRATION 2
The indicator displays .Press the key to perform the zero calibration.
3.8.4 SPAN CALIBRATION SPAN CALIBRATION 1
After performing the zero calibration without error, the indicator displays , press key to skip the span calibration if only zero adjustment is required.
SPAN CALIBRATION 2
Put the standard weight which equals to the scale capacity to the carriage. Use thekey and the key to set the reading of the indicator exactly the same
as the value of the standard weight(press key to change the position of decimal point then press key to change the value).
MODE
MODE
ENTER
MODE
ENTERMODE
TARE
ZERO
ZERO TARE
TARE
ZERO
52 CB920X Instruction Manual
CB920X
3.8.5 ERROR CODE DURING CALIBRATIONError 1 : Incorrect setting for multiplier, division, step width or max. capacity.
Error 2 : Incorrect wiring between load cell and indicator.
Voltage for zero value is greater than the voltage for span value.
Error 3 : Input voltage too low. The dead weight of the weighing platform may be too light.
Add a 1% metal film resistor between EX+ and SG+.
Error 4 : Input voltage too high. The dead weight of the weighing platform may be too heavy. Add a 1% metal film resistor between EX+ and SG-.
Error 5 : Input sensitivity of load cell is too low.
Error 6 : Load cell output voltage at scale capacity is too high.
3.9 CALOBRATION BY USING RS232/RS485Calibration function can be activated by using RS232/RS485. Function setting should be performed before scale calibration.At normal weighing condition, input a command CAL. The gross display will show .
Command input CB920X ResponseCAL
3.9.1 ZERO CALIBRATIONCAL ZERO
Input N, R or JN = perform a zero offset calibrationR = return to the normal weighing condition without any adjustmentJ = skip the zero offset calibration
Note: If maximum capacity, division or multiplier was changed and no calibration is performed after the modification, the R command will be invalid.
CB920X Instruction Manual 53
Be sure that there is nothing on the platform and no motion is detected, then input N command to perform the zero offset calibration.
N Error 3N Error 4
Error 3: Input voltage too low. The dead weight of the weighing platform may be too light.
Add a 1% metal film resistor between EX+ and SG+.
Error 4: Input voltage too high. The dead weight of the weighing platform may be too heavy.
Add a 1% metal film resistor between EX+ and SG-.
N YES YES = zero offset calibration is performed.
3.9.2 SPAN CALIBRATIONAfter performing the zero calibration without error, the message YES and
CAL SPAN will be sent out.
Input R to return to the normal weighing mode and system was only performed a zero offset calibration. Note: If maximum capacity, division or multiplier was changed and no calibration is
performed after the modification, the R command will be invalid.
Put the standard weight to the weighing platform, after no motion is detected, enter the total weighing figure of the standard weight to perform a span calibration.
10000 Error 25000 Error 620000 Error 1
Error 1: Incorrect setting for multiplier, division, or maximum capacity.Error 2: Incorrect wiring between load cell and indicator. Voltage for zero value is greater than the voltage for span value.Error5: input sensitivity of load cell is too low.Error 6: Load cell output voltage at scale capacity is too high.
100000 CAL SPAN 100000 YESYES = Calibration completed.
54 CB920X Instruction Manual
CB920X
CB920X
3.10 SETTING THE SETPOINTDuring the setpoint process, the key, the key, the keyand the : has the following function:
key : It is used to advance to the next step. key : It is used to select the digit to be modified. The decimal point of
the selected digit will be flashing.
key : It is used to change the value of the digit selected. key : It is used to return to weighing mode.
Start the setting process:
Press and hold the key, press the key without releasing the key. The indicator display for 2 seconds.
During the process, we can set the setpoint of 4 different materials, The following table is the relationship of the annunciator to the material.
ANNUNCIATOR MATERIAL# M1 1
M2 2M3 3M4 4
Step 1
The annunciator of material 1 is lit, gross display showing with decimal point flashing at least significant digit. Tare display showing , indicates that final setpoint value is required.
MODE TAREZERO
MODE
ZERO
TARE
ENTER
ENTER
ZERO
ENTER ZERO
TARE
ZERO
ENTER
ENTER
CB920X Instruction Manual 55
CB920X
CB920X
CB920X
CB920X
Use key and key to enter the figure.Use key to go to next step.
Step 2
Gross display showing with decimal point flashing at least significant digit.Tare display showing , indicate that coarse setpoint value is required.
Use key and key to enter the figure.
Use key to go to next step.
Step 3
Gross display showing with decimal point flashing at least significant Digit.Tare display showing , indicates that medium setpoint value is required.Medium setpoint is optional software(CB920A).
ZERO
MODE
MODE
TARE
MODE
ZERO TARE
MODE
56 CB920X Instruction Manual
CB920X
CB920X
CB920X
CB920X
Use key and key to enter the figure.
Use key to go to the next step.
Step 4
Gross display showing with decimal point flashing at the least significant digit.Tare display showing , indicates that fine setpoint is required.
Use key and key to enter the figure.
Use key to go to the next step.
ZERO
ZERO
TARE
MODE
TARE
MODE
ZERO
TARE
MODE
MODE
ZERO TARE
CB920X Instruction Manual 57
CB920X
Step 5
After entering the fine setpoint, CB920X perform a checking on the data entered. The setpoint should fulfill the following condition:
final setpoint>coarse setpoint>medium setpoint>fine setpointIf the above condition is fulfilled then next material will be selected(material1, 2, 3, 4 and then back to 1). Repeat step 1 to 4 until all setpoint is entered.
Step 6After all the setpoint value is entered. Press key to return to normal weighing condition.
Note: If accumulative total of final setpoint of all material is greater than maximum capacity, then CB920X will not return to normal weighing condition.
ENTER
ENTER
58 CB920X Instruction Manual
CB920X
3.11 SETTING SETPOINT BY USING RS232/RS485At normal weighing condition, input a command SET , the gross display will show .
Command Input CB920X ResponseSET
(a) FINAL SETPOINTThe annunciator of M1 is lit
M1 FINAL 1000 Input the final setpoint value
12345 M1 FINAL 12345or input J to skip to next material
or input R to return to normal weighing condition or input N to set coarse setpoint
N
(b) COARSE SETPOINTM1 COARSE 123
Input the coarse setpoint value100 M1 COARSE 100
or input N to go to medium(3 stages batching option)or fine setpoint.N
(c) MEDIUM SETPOINT(3 STAGES BATCHING OPTION)M1 MEDIUM 100
Input the medium setpoint value50 M1 MEDIUM 50
or input N to go to fine setpointN
(d ) FINE SETPOINTM1 FINE 50
Input the fine setpoint value20 M1 FINE 20
or input N to go to next material setpointN
The material 1 setpoint is end, then enter the next setpoint, repeat (a), (b), (c), (d) .(Note: M2, M3, M4 replace M1).After all setpoint values are entered, input R to return to normal operation condition.
R YESYES = Setpoint value storedNO = Setpoint value invalid, system can not return to normal weighing condition.
CB920X Instruction Manual 59
3.12 THE BATCHING OPERATION
Start The weighing hopper is empty, the display shows 0, and all gates are closed.When the start button is being pressed, the pin START short to pin COM. material 1, coarse, medium(3 stages option)and fine outputs go on.
Comment: If gate switch control relays are connected as listed above-the supplying bin gate will be opened using the coarse, medium and fineoutput-on signal.
CB920X When the display reaches coarse setpoint, the coarse output signal will be off.
Comment: The coarse-flow gate will be closed by using the coarse output of signal.
CB920X When the display reaches medium setpoint, the coarse output signal will be off .
Comment: The medium-flow gate will e closed by using the coarse output of signal.
CB920X When the display reaches fine setpoint, the fine output signal will be off.Comment: The gate will be closed by using the fine output off signal. After time
delay for tolerance check(TTC), Tolerance will be checked by CB920X. If net weight batches is out of the tolerance range(i.e. 0.1~9.9%), then
the output of out of tolerance will e activated by 0.5sec.
CB920X The above process will be repeat for material 2,3,4 and one by one .
CB920X Data output is sent (auto or continue mode:RS232/RS485).
CB920X Discharge output will be activated until gross weight is less than zero band and time delay for discharge control(TDC)is over.
CB920X Ready for next batching event.If an abort signal is received anytime after the start is received, then the coarse, medium and fine signals go off, gates will be closed.During a normal batching event, do not press the TARE.
Note: 1. Batching abort signal can be sent by RS232/RS485 input or activated by press the , and key simultaneously.
3. Discharge abort signal can be activated by pressing and hold the key for 1sec.
ZEROTAREMODE
ENTER
60 CB920X Instruction Manual
MEDIUM FLOW GATEFINE FLOW GATE
WEIGHING SYSTEM DIAGRAM:
COARSE FLOW GATE
DISCHARGE GATE
LOADCELL
WEIGHINGHOPPER
STORAGE HOPPER
LOADCELL
CB920X Instruction Manual 61
Discharge
Medium Setpoint Fine Setpoint Final SetpointACTUALWEIGHT
NET WEIGHT
2000
(1000-50) 950
(1000-100) 900
Material 1
Material 2,3,4
Coarse
Material
Fine
Discharge
Out of Tolerance
Data Output
Start
SDT TTC TTC TDC
Start
CONTROL TIMING DIAGRAM:
Example: FINAL : 1000COARSE : 100MEDIUM : 50FREE FALL : 30
TTC: Time delay for tolerance checkTDC: Time delay for discharge controlSDT: Start delay time
Coarse Setpoint
Zero Range 2%
1000(1000-30) 970
62 CB920X Instruction Manual
Attention: Please note that the idea if free fall is based up on the concept of solids falling(After the flow has been cut to zero) from a supply bin into a weighing hopper.When liquids are being added to a weighing hopper, wave propagation must be kept to a minimum to avoid load oscillation. If a submerged filling plan isemployed(which may zero free fall) liquid displacement must be take into consideration.
3.13 BASIC OPERATIONConnection the power cable, the indicator will flag that there has been a power interruption with the display , if this display occurs at any other time you should regard it as a warning that volatile memory(weighing event data)will have been lost. Please allow a warm-up period to achieve thermal stability in the load cell and indicator. Zero will drift initially. To sustain thermal stability you should keep the indicator on.Set and calibrate the indicator as described in the function setting, the setpoint setting and calibration section.When the production start button as shown in connection for control output and input is pressed and the released, production is immediately and materials are batched one by based on the setpoint entered(i.e. from M1, M2, M3, M4).
3.14 OTHER INDICATION3.14.1 DISPLAY
The display will blank and net display when the input signal exceeds the maximum capacity by more than 9 step width.If no load cell is connected to the indicator, or the display value is too low below zero, the display will also blank and net display .
3.14.2 DISPLAY When power up the indicator or power interrupted, will be displayed.
3.14.3 DISPLAY The indicator will display if there is any error detected during the diagnostic function immediately after power up.
: memory for function setting is lost, set again: memory for scale calibration is lost, set again: memory for setpoint is lost, set again: internal memory is lost, unit should send back to manufacturer: internal memory is lost, unit should send back to manufacturer: internal memory is lost, unit should send back to manufacturer
CB920X Instruction Manual 63
4.1 BCD DATA OUTPUT INTERFACE1) PIN DESCRIPTION
Pin No. Signal Pin No. Signal1 BCD1 18 BCD200002 BCD2 19 BCD400003 BCD4 20 BCD800004 BCD8 21 BCD1000005 BCD10 22 LO=negative polarity6 BCD20 23 LO=Overload7 BCD40 24 Print8 BCD80 25 LO=Gross9 BCD100 26 LO=Motion detected10 BCD200 27 LO=kg11 BCD400 28 N.C.12 BCD800 29 LO=Decimal point 1/1013 BCD1000 30 LO= Decimal point 1/10014 BCD2000 31 LO= Decimal point 1/100015 BCD4000 32 LO= Decimal point 1/1000016 BCD8000 33 Ground17 BCD10000 34 Ground
BCD
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34
2 8 2 8 2 8 2 8 2 8 POL
P.C
MO
TIO
N
N.C
DP
2
DP
4
D.G
ND
OV
ER
GR
OSS
/NET
UN
IT
DP
1
DP
3
D.G
ND41 41 41 41 41
100 101 102 103 1041
105
4. OPTIONS
100 101 102 103 104
64 CB920X Instruction Manual
2) DESCRIPTION OF BCDSIGNALl LO = CMOS low level voltage
l BCDDATA OUTPTUTPin number 1 to 21 is BCD data output in CMOS level.
l GROSSA CMOS low signal indicated that the indicator is in GROSS mode. A CMOS high signal indicates that the indicator is in NET mode.
l MOTION DETECTEDThis signal becomes CMOS high level when motion is detected.
l kg ACMOS low signal indicated that the unit selected. A CMOS high signal indicated that the unit selected is ton.
l NEGATIVE POLARITYA CMOS low signal indicates that negative reading will be displayed. A CMOS high signal indicates that negative reading will not been displayed.
l DECIMAL POINTA CMOS low signal indicates the decimal point.XXXX.X Decimal point 1/10XXX.XX Decimal point 1/100XX.XXX Decimal point 1/1000X.XXXX Decimal point 1/10000
l OVERLOADA CMOS low level indicates that there is overload.
l PRINT COMMANDA positive pulse will be sent out for each valid data.
CB920X Instruction Manual 65
4.2 CB920X ANALOG OPTION
Specification
Resolution: 1/10000
Output 0~5V 0~20mA 4~20mALoad resistor Mix.10K Max. 500 Max. 500the output voltage/current at the display equals 0 0V 0mA 4mA
the output voltage/current at the display equals maximum capacity 5V 20mA 20mA
When the display equals 0, the output voltage/current is 0V/0mA/4mA.When the display equals maximum capacity, the output voltage/current is 5V/20mA.
Note: When the display equals negative, the output voltage is 0V.
MA
TER
IAL
1
MA
TER
IAL
2
MA
TER
IAL
3
MA
TER
IAL
4
CO
AR
SE
FIN
E
DIS
CH
AR
GE
TOLE
RA
NC
E
EMTR
CO
M
TXD
(+)
RX
D(-
)
CO
M
+ CO
M
OPT
ION
AN
ALO
GO
UT
PHOTO OUTPUTRS232/RS485
66 CB920X Instruction Manual
PRONT PANEL PANEL CUTOUT
REAR PANEL SIDE PANEL
96mm
48mm
+0.4- 0.0
+0.6 - 0.0
5. DIMENSION
CB920X BATCHING CONTROLLER
ENTER MODE TARE ZERO
M1
MOTION
ZERO
M2
M3
M4
91
45
mm
mm
48m
m
162mm
CB920X Instruction Manual 67
CB920X REPORT PRINT OUT FOR PRODUCTION ABORTM1 , AB , + 12.69kgM2 , AB , + 0.00kgM3 , AB , + 0.00kgM4 , AB , + 0.00kg
(If production is aborted manually or the scale excess the maximum capacity, the above report will be printed out) .
6. APPENDIX
CONTENTS
1. GENERALDESCRIPTION1.1 Introduction .. ...11.2 Definition 11.3 Features ...3
2. SPECIFICATION2.1 General 42.2 Digital Section 42.3 Analog Section 42.4 RS232/RS485 Serial Output ... 5
3. OPERATION3.1 General Rules 103.2 Input Sensitivity of Load Cell ...103.3 Connecting the Load Cell to the Indicator 103.4 Front panel Description .123.5 Rear panel Description ..133.6 Function Setting 173.7 Function Setting By Using RS232/RS485.. . .433.8 Calibration .503.9 Calibration By Using RS232/RS485 .523.10 Setting the Setpoint.. . ..543.11 Setting the Setpoint By Using RS232/RS485 .583.12 The Batching Operation ..593.13 Basic Operation .. .. ...623.14 Other Indication ...62
4. OPTIONS4.1 BCD Data Output Interface ...634.2 CB920X Analog Output Interface .. ...65
5. DIMENSIONDimension ...66
6. APPENDIX CB920X Report Print Out For Production Abort 67
CB920XBATCHING CONTROLLER
INSTRUCTION MANUAL
VER 2000.09
Chi Mei Electronics Co., Ltd.Flat D, 13/F, Por Mee Fty.Bldg., 500 Castle Peak Road, Lai Chi Kok, Kowloon, Hong KongTel : (852)27444419Fax : (852)27442060E-mail : [email protected] : http://www.chimei.com.hk
MC
page1page2page3page4page5page6page7page8page9page10page11page12page13page14page15page16page17page18page19page20page21page22page23page24page25page26page27page28page29page30page31page32page33page34page35page36page37page38page39page40page41page42page43page44page45page46page47page48page49page50page51page52page53page54page55page56page57page58page59page60page61page62page63page64page65page66page67page68page69page70page71