70
ISOKINETIC CATALOG XC-522 XC-5000 XC-40 Av. Juan Bautista Alberdi 5283 1°P Ciudad Autónoma de Buenos Aires Tel: +54 11 4684 2232 http://www.siafa.com.ar [email protected]

Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

Embed Size (px)

DESCRIPTION

Catalogo de isocinetismo

Citation preview

Page 1: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

IsokInetIc catalog

XC-522

XC-5000

XC-40

Av. Juan Bautista Alberdi 5283 1°PCiudad Autónoma de Buenos AiresTel: +54 11 4684 2232http://[email protected]

Page 2: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

ISOKINETIC SOURCE SAMPLING EQUIPMENT

FLOW, PRESSURE & TEMPERATURE

MERCURY ANd GAS SAMPLING SYSTEMS & EQUIPMENT

GAS ANALYSIS EQUIPMENT

APPENdIX

INdEX

ACCESSORIES

Meter Consoles............................................5 - 11

Sample Pumps ............................................12, 13

Nozzles & Nozzle Accessories .......................14, 15

Probes, Liners, Sheaths & Accessories..........16 - 18

Modular Sample Case AssembliesFilter Ovens, Impinger Cases, Risers .............19 - 21

Glassware, Adapters & Impingers ..................22 - 28

Umbilical Cords, Sample LinesMethod 4, Method 5 ....................................29 - 34

Method 8, Method 17, Method 23 Method 7C & 7D ..........................................35 - 38

Method 26A, Method 29, Ontario-Hydro ..............................................39 - 41

Method 201A, Cascade Impactor Kit, Method 202 ..................................................42 - 46

Filter Media, Sample Recovery Desiccator and Desiccants ........................47 - 51

Silica Gel, Balances Calibration Weights .....................................52 - 55

Calibration Equipment, Monorails .............56 - 60

XC-522/XC-572 Components List ............61

Appendix .......................................................62-66

Isokinetic Index ............................................67

isokinetic sampling equipment

Stationary source sampling is conducted to evaluate gas stream emissions to the atmosphere from stacks, ducts or process exhausts. A pol-lutant’s concentration is measured by extracting a known volume from the gas stream and determining the average stack gas flow rate over the sampling period. The mass emission rate of each constituent then may be calculated. In the area of Stack Sampling Methods, there are 3 major categories of test-ing: Isokinetic Reference Methods, Instrumental Reference Methods (IRM), and Gaseous Sampling (which includes sampling for mercury). Obtaining a representative sample of particulate matter from a gas stream requires a more complex procedure than sampling only for gases. Particles can be either liquid droplets or solids. Representative sampling requires that the velocity of the gas/particle mixture passing into the sampling nozzle must be as close as possible to the velocity of the gas stream in the stack or duct. When the velocities are the same, the sampling is isokinetic. During the entire sampling period, the stack velocity must be monitored constantly and the pumping rate adjusted so that the nozzle intake veloc-ity matches as closely as possible the velocity of the in-stack gas/particle mixture. In addition, the pumping rate needs to be adjusted for differences in pressure, temperature and moisture between the stack conditions and the pump or meter console. The exact steps to conduct this type of sampling are spelled out in U.S. EPA Reference Method 5. This method also requires knowledge of U.S. EPA References Methods 1 through 4. The Apex AutoKineticTM method 5 sampling system offers modular components that can be arranged and re-arranged to perform multiple U.S. EPA Reference Methods. Select from manual, digital or automated meter consoles, as well as a wide range of heated filter and impinger boxes, heavy-wall glassware with unground o-ring ball joints, probes built to customer specified lengths, new designs for umbilical cords, and custom modifications to meet your unique needs. All delivered in a timely manner at a competitive price. For over 22 years, Apex Instruments, Inc., has concentrated on manufacturing equipment designed for use in sampling stationary combustion sources. Apex Instruments has always been directly involved with the envi-ronmental industry, working close with the U.S. EPA. When the Clean Air Act was enacted in 1990 and hazardous air pollutants were identified for control, Apex Instruments was at the forefront of product design, method evaluation and implementation.

ISOKINETIC SAMPLING EQUIPMENT

Page 3: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

62

ISOKINETIC SOURCE SAMPLING EQUIPMENT

Delivery:Most orders are shipped within 24 hours of receipt. Please allow extra time for custom orders. Shipping times vary according to the requested shipping service. If you have questions about your shipment please email our shipping management at [email protected].

Return Merchandise AuthorizationCustomers wishing to return items for service or credit need to contact our sales associates for an RMA. Contact by email at [email protected] or by phone (919) 557-7300 or toll free (800) 882-3214.

PricingPrices are published for U.S. customers only. International customers should contact their local distributor. Prices are in U.S. Dollars, FOB shipping point, or Ex Works for International orders. Please confirm current prices by phone, fax or email. Please refer to our price list for a complete list of part numbers and kit configurations.

PaymentFor your convenience, MasterCard, VISA and American Express arewelcome. Company purchase orders are accepted upon credit approval.

We back up this commitment with extensive knowledge of our products, good communication and an excellent customer service history. Our equipment isdesigned by experienced stack testers who know what you face when performing compliance testing.

We encourage you to suggest ideas to improve our equipment. We work closely with you, over the long term, to provide the best equipment for your needs.

CUSTOMER SATISFACTION is guaranteed at APEX INSTRUMENTS.

Page 4: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

3

ISOKINETIC SOURCE SAMPLING EQUIPMENT

Apex Isokinetic Source Sampling Systems are rugged versatile equipment designed for extracting a representa-tive flue gas sample from a source to determine dust and fumes emissions in accordance with many U.S. EPA Reference Methods as published in CFR 40 Part 60 Appendix A. The Apex Isokinetic Source Sampling System allows the operator to monitor gas velocities, temperatures, pressures and adjust sample flow rates to obtain a representative flue gas sample.

The results are often used to prove compliance with existing and applicable regulations. It can also be used to characterize the gas stream, tune or optimize the process or combustion source, or validate control processes in place.

isokinetic source sampling /method 5 and associated methods

Modular Sample Cases, page 19

Probes and Liners, page 16 - 18

Consoles, page 4 - 11

Pumps, page 12 - 13

Umbilicals, page 29

Nozzles, page 14

Glassware, page 22

Featuring the XC-5000 AutoKineticTM Sampler

Versatile System designs for Multiple Methods:

The Apex Method 5 Source Sampling System can be configured with various accessories and used to sample a wide range of pollutants, such as metals, halides and halogens, polychlorinated biphenyls (PCBs), dioxins/furans, polycyclic aromatic hydrocarbons (PAH’s), particle size distributions and an ever-increasing group of pollutants by adaptations of basic test methods. Within our catalog we feature sampling kits and accessories for the most popular isokinetic methods and pollutants of interest. A list of featured methods can be found on page 4.

Method 1 Determination of Sampling Location and Traverse PointsMethod 2 Determination of Stack Gas Velocity and Volumetric Flow RateMethod 3 Determination of Excess Air and Dry Molecular WeightMethod 4 Determination of Moisture In Stack GasesMethod 5 Determination of Particulate Emissions from Stationary Sources

Isokinetic Testing Requires a Thorough Understanding of the First Five Test Methods Presented in the CFR 40 Part 60, Appendix A.

Method 5 - CompactMethod 5 - FlexibleMethod 5 - Rigid

Method 17Method 23Method 26A

Method 29Method 201AMethod 202

Page 5: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

4

ISOKINETIC SOURCE SAMPLING EQUIPMENT

See Links for Methods on Our Website

See Links for Gas Testing Methods

See Links for Flow Testing Methods

METhOd dESCRIPTIONMETHOD 4 Determination of MoistureMETHOD 5 Determination of Particulate

Emissions from Stationary SourcesMETHOD OTM-28 Controlled CondensateMETHOD 17 Particulate by In-stack FiltrationMETHOD 23 Dioxins and Furans

METHOD 0061 Hexavalent Chromium

Recommended Accessories to Convert M5 Kit to Perform:METHOD 26A Hydrogen Halides and HalogensMETHOD 29 Multiple MetalsMETHOD 201A PM10 EmissionsMETHOD 202 Condensable Particulate Matter,

PM 2.5ONTARIO HyDRO ASTM-D6784-02 Mercury

hOW TO GET STARTEd Versatile system designs are available to serve complex and challenging stack testing locations. The Method 5 System, combined with the appropriate accessories, can be used to sample a wide range of pollutants, such as dust, metals, polychlorinated bi-phenyls (PCBs), dioxins/furans, polycyclic aromatic hydrocarbons (PAH’s), particle size distributions and an ever-increasing group of pollutants by adaptations of basic test methods. Contact our helpful sales staff to configure a system to meet your needs.

SELECT METER CONSOLESelect a meter console that is appropriate for the test method and select a configuration that suits your specific conditions.

ChOOSE A PUMPChoose an external pump that suits your specific conditions and desired flow rates.

dETERMINE SAMPLING KITS REQUIREMENTSSelect method specific accessories and kits to complete your system.

NEEd ASSISTANCE?We are never more that a phone call away during normal business hours, and would be glad to help answer any questions you may have. hours of Operation: Monday through Friday from 8:00 am, until 5:00 p.m. (EST).

Fax : (919) 557-7110Email : [email protected] # : (919) 557-7300 (800) 882-3214

Rigid-Set-up

FEATUREd METhOdS Apex Instruments method kits are available for the most popular methods. After choosing the meter console and sample pump, purchase the kit you need to conduct the desired method.

Flexible System

Console & Pump

Page 6: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

5

ISOKINETIC SOURCE SAMPLING EQUIPMENT

multiple-methodAutoKineticTM Sampler Console

The Apex Instruments XC-5000 AutoKineticTM Sampler is designed for conducting US EPA Method 5 and associated isokinetic methods. Take the worry out of isokinetic calculations and the human error out of data entries recorded by hand. The new XC-5000 is compatible with your existing Method 5 stack sampling components. Report preparation is streamlined with accurate data downloadable to files for easy preparation and submission to your regulating agency.

XC-5000 AUTOKINETICTM SAMPLER CONSOLE

Features • Uses standard Apex Instruments sample train components (probe, nozzle, heated filter box, impinger box, etc.)

• Maintains isokinetic sampling conditions without operator assistance

• Calculates stack traverse points

• Calculates correct nozzle diameter for site conditions

• Stores and displays user entered data and parameters

• Upload and download data files

• Performs instantaneous isokinetic sample flow calculations

• Timer alerts operator to move the probe

• Alarms indicate when acceptable conditions are not met• English or metric units selectable

Model description

XC-5000 AutoKineticTM Sampler Console, 110V

XC-5000-V AutoKineticTM SamplerTM Console, 240V

Sample Pump: Accepts standardmethod 5 pump assemblies.

XC-5000 Isokinetic Source Sampler

XC-5000AutoKineticTM SamplerConsole with Laptop

Wireless or Ethernet Connection Available

Main Power

ProbePower

Color CodedThermocouple

Jacks

Stainless SteelVacuum Pump

Quick Connects

Pump PowerConnection Stainless Steel

Pitot QuickConnects

Ethernet Interface

Umbilical Cable Power Connection

Stainless Steel Sample Quick Connect

LED Display

LEDIndicator

Delta H Calibration

External

Connections

Page 7: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

6

ISOKINETIC SOURCE SAMPLING EQUIPMENT

Specifications

Optional:4 channel analog input module for logging external data (4-20ma, 0-10V, 1-5V).

dimensions:23” x 21” x 12” (58 cm x 53 cm x 30.5 cm).

Weight: 39 lbs. (17.7 kg).

Power: 120V / 60 Hz. 220V / 50 Hz (optional).

Console Power Requirements:120V 15amp max.

Umbilical Connections:Electrical: 4 conductor circular connector grounded shell.Sample line: Stainless Steel 1/2” Quick Connector.Pitot Line: Stainless Steel 1/4” Quick Connectors (optional 3/8”).External pump: Stainless Steel 3/8” Quick Connect.Thermocouples: Type-K standard size.

Communication:Wireless and Ethernet.

Gas Meter: Model AP25, Precision DGM, 0.7 liters per revolution, digital gas volume with Internal Quadrature Encoder with 6 digit LCD display, 1cc resolution.

Temperature Control: Integrated temperature control via the Control and Data Acquisition Board, probe and oven with solid state relays.

Thermocouple display: 7 temperatures displayed simultaneously on the PC User Interface, °F or °C, Probe, Stack, Oven, Filter, Exit, AUX and DGM.

Digital Pressure Transducers for H, and P (Bi-Directional), Barometric.

P +/- 2.5” 0.01” resolution +/- 63mm 0.01 mm resolution

H 0”-5” 0.01” resolutions 0mm-127mm 0.01mm resolution

Barometric 17.7 inHg – 32.5 inHg 0.01 inHg resolution 450 mmHg – 825 mmHg 0.01m mmHg resolution

XC-5000 software screen shot.

Features

• Uses Standard Apex Instruments Sample Train Components (Probe, Nozzle, Heated Filter Box, Impinger Box)• Calculates Stack traverse Points (Method 1)• Stores and Displays User Entered Data and Parameters• Performs Instantaneous Isokinetic Sample Flow Calculations & Controls Isokinetic Flow• Timer Alerts Operator to Move the Probe• English or Metric Units

XC-5000 AutoKineticTM SamplerConsole and Laptop

Wireless or Ethernet Connection Available

Page 8: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

7

ISOKINETIC SOURCE SAMPLING EQUIPMENT

ISOKINETIC SOURCE SAMPLING CONSOLE - MANUALThe XC-500 Series Sampling Console is a rugged, lightweight metering console used to extract gas samples in accordance with US EPA Method 5 for determining source emissions for dust and fumes. The Apex Isokinetic Source Sampler allows the operator to monitor gas velocities, temperatures, pressures and adjust sample flow rates to maintain isokinetic sampling conditions. Comes with digital temperature controllers, a choice between digital or liquid manometers, digital temperature displays and external pump connections. Stainless steel fittings and quick connects are standard. Units in the XC-500 Series are available in Standard or Metric units, 110V or 220VAC, optional internal orsat pump. XC-500 Series Sampling Console features a molded, rugged X-case with side handles for attaching the easy carry strap. The X-case allows for rear door access. Apex Instrument’s Isokinetic Sampling Consoles are manufactured to conform to the construction design criteria and specifications cited in U.S. EPA Method 5, Code of Federal Regulations (40 CFR Part 60) and APTD-0581 documents. All Apex consoles are calibrated prior to shipping.

Slide Out Front PanelThe meter console has a slide-out panel for easy access.

Rear ViewRemovable back panel allows for quick audits.

PortableX-case with sample pump on portable hand cart. (optional)

Temperature Display Manometer Quick

Connects

Dual Column Manometer

Coarse Control Valve

Dry Gas Meter

Fine Control Valve

Heavy Duty Panel Latches

Manometer Zero Adjust Knobs

Manometer Level Adjust

StandardStainless Steel Pitot

Quick Connects

StandardStainless Steel

Sample Quick Connect

Standard Stainless Steel Pump Connection

(Pressure)Umbilical

Cable Power Connection

Color Coded Thermocouple Jacks

Temperature Selector Switch

Vacuum Gauge

Elapsed Timer

Rocker Switches with Magnetic

Circuit Breakers

Optional Orsat Pump and

Rotameter

Rugged Custom Molded X-Case

Digital Filter and Probe Temperature

Controllers

Stainless SteelNon-Reversible Pump

Quick Connect(Vaccum)

Strap

Page 9: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

8

ISOKINETIC SOURCE SAMPLING EQUIPMENT

XE-0523 Sample Pump Mounted in UhMWPolyethylene Case• Motor: 1/4 hp, 120/240V 60/50Hz 4.6/2.3 Amp., RPM 1725/1425• Measured Flow: 3.1 cfm@ 1 inch Hg; 1.5 cfm@ 15 inches Hg • Maximum Vacuum: 25.5 inches Hg • Weight: 35 lbs. (16kg)

XC-522 Source Sampling ConsoleThe Apex Instruments Model XC-522 is a full featured manual meter console. The Apex Isokinetic Source Sampling Console allows the operator to monitor gas velocities, temperatures, pressures and adjust sample flow rates to maintain isokinetic sampling conditions. Designed with convenient display layout for manual data recording.The Apex Instruments Isokinetic Source Sampling Consoles are manufactured to conform to the construction design criteria and specifications cited in U.S. EPA Method 5, Code of Federal Regulations (40 CFR Part 60) and APTD-0581 documents.

Features:• Low Cost - Manual Console• Easy to Operate and Maintain• Rugged, Lightweight, Stackable Case• Removable 19” Front Panel• Carry Strap for Easy Transport• Non-Reversible Sample Pump Connections• Color Coded Thermocouple Jacks• Bright, Easy-to-Read Temperature Displays• Easy-Leveling Dual Column Manometers• Dry Gas Meter with direct read index• Stainless Steel Quick Connects & Fittings

Model description

XC-522 English Meter Console, 120 V/60 Hz

XC-522-V English Meter Console, 240 V/50 Hz

XC-522-O English Meter Console with optional Orsat Pump Assembly, 120 V/60 Hz

XC-522-OV English Meter Console with optional Orsat Pump Assembly, 240 V/50 H

XC-522 English Units (Cubic Feet, oF)

XC-522 Source Sampler

XC-522 Recommended Accessories

Nomographs & Calculators, See Accessories Section

Page 29d

Specifications

Temperature Controllers for Probe and Oven: 1/32 DIN bright red LED display, indicating temperature controllers with separate 25 amp solid state relay, auto-tuning. Standard Type-K jack for input.

Vacuum Gauge: Dual Scale Vacuum Gauge, 0-30” Hg / 0-100kPa.

Sample Pump Connections: 3/8” Quick Connects, Stainless Steel, non-reversible.

Umbilical Connections: Sample Inlet: ½” Stainless Steel Quick-Connect; Pitot Lines: 1/4” (3/8” optional) stainless steel Quick Connect; Electrical: 4 conductor circular connector; Thermocouples: 6 Type K inputs, standard size.

Power: 120V/60Hz standard; 240V/50Hz optional

dimensions: 23” x 21” x 12” (58 x 53 x 30cm) Panel 19”

Weight: 43 lbs (19.5kg)

Gas Meter: Rockwell S110 remanufactured with direct read index, 0.1 cubic feet/revolution, res. 0.001 cubic feet direct read analog totalizer with 999.999 cubic feet capacity.

Manometer: Dual Inclined/Vertical Manometer for determining stack velocity and sample flow rate. Inclined Range 0-1.0” H²0 with 0.01 divisions. Vertical Range 1-10” H²O with 0.1” divi-sions. Fabricated from solid acrylic, precision bored, accurate to +/- 1%. Convenient self-sealing chrome plated brass quick-connects with Viton® O-Rings. Supplied with plastic plugs for positive secondary seal. Temperature display: Panel mount digital thermometer, bright red LED display, 1/8 DIN plastic housing, Range -157° to 1999°F, with separate 7-channel selector switch.

Sample Pumps are sold separately, Page 12-13

Page 10: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

9

ISOKINETIC SOURCE SAMPLING EQUIPMENT

XC-572 Source Sampler

Model description

XC-572 XC-572 Isokinetic Meter Console, Metric, 120V/60Hz

XC-572-V XC-572 Isokinetic Meter Console, Metric, 240 V/50 Hz

XC-572-O XC-572 Isokinetic Meter Console, Metric, with optional Orsat Pump Assembly, 120V/60Hz

XC-572-OV XC-572 Isokinetic Meter Console, Metric, with optional Orsat Pump Assembly, 240 V/50 Hz

XC-572 Metric Units

XC-572 Source Sampling ConsoleThe XC-572 Source Sampling Console is the metric version of the XC-522. It is a full featured, compact, and lightweight Isoki-netic Source Sampler. It has all the great features you want and the reliability you need. Field set up is easy with non-reversible external pump connections and the industry standard 4-pin electrical connector. (External sample pump sold separately).Console allows operators to monitor gas velocities, tempera-tures, pressures, and sample flow rates for maintaining isokinetic sampling conditions.

Specifications

Gas Meter: AP-25 easy to read numeric index with leak check wheel, low pressure drop, rated 42 lpm at 15mm H2O, maximum capacity approx. 70 lpm. Totalizer capacity 9999.9999 cubic meter, resolution 0.1 Liter.

Manometer: Dual Inclined/Vertical Manometer for determin-ing stack velocity and sample flow rate. Inclined Range of 0-26mm H²0 with .2mm. Vertical Range of 26-250mm H²O with .2mm. Fabricated from solid acrylic, precision bored, accurate to +/- 1%. Convenient self-sealing chrome plated brass quick-connects with Viton® O-Rings. Supplied with plastic plugs for positive secondary seal.

Temperature display: Panel mount digital thermometer, bright red LED display, 1/8 DIN plastic housing. Range -105°C to 1372°C, with separate 7-channel selector switch.

Temperature Controllers for Probe and Oven: 1/32 DIN bright red LED display, indicating temperature controllers with separate 25 amp solid state relay, auto-tuning. Standard Type-K jack for input.

Vacuum Gauge: Dual Scale Vacuum Gauge, 0-30” Hg / 0-100kPa.

Sample Pump Connections: 3/8” Quick Connects, Stainless Steel, non-reversible.

Umbilical Connections: Sample Inlet: ½” Stainless Steel Quick-connect; Pitot Lines: 1/4” (3/8” optional) Stainless Steel Quick Con-nect; Electrical: 4 conductor circular connector; Thermocouples: 6 Type K inputs, standard size.

Power: 120V/60Hz standard; 240V/50Hz optional.dimension: 23” x 21” x 12” (58 x 53 x 30cm) Panel 19”.Weight: 40 lbs (18kg)

Features:• Precision gas meter with leak check indicator• Low Cost - Manual Console• Easy Operation and Maintenance• Rugged, Lightweight, Stackable Case• Removable 19” Front Panel• Carry Strap for Easy Transport• Non-Reversible Sample Pump Connections• Color Coded Thermocouple Jacks• Bright, Easy-to-Read Temperature Displays• Easy-Leveling Dual Column Manometer• Stainless Steel Quick Connects & Fittings• Convenient Layout for Manual Data Recording

Low Flow Adapters,VUA,

See Accessories Section

Page 18d

XC-572 Recommended AccessoriesXE-dAA Sample Pump Mounted in UhMWPolyethylene Case• Motor: 1/2 hp, 120V/60Hz 5 1/2 Amp• 2.9 cfm@ 1 inch Hg; 1.4 cfm@ 15 inches Hg • 26.5 inches Hg • Weight: 30 lbs. (14kg)

Sample Pumps are sold separately, Page 12-13

Page 11: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

10

ISOKINETIC SOURCE SAMPLING EQUIPMENT

XC-563 dIGITAL SOURCE SAMPLING CONSOLEApex Instruments Model 563 Source Sampling Console is thedigital equivalent to the XC-522 and XC-572; featuring an AP25Dry Gas Meter with optical encoder and digital totalizer. Theconsole also features differential pressure transducers for Pand H. The temperature controllers, thermometer and timerall have digital displays.

XC-563 Source Sampler

Model description

XC-563 XC-563 Meter Console, 120V/60Hz

XC-563-V XC-563 Meter Console, 240V/50Hz

XC-563-O XC-563 Meter Console, with optional Orsat Pump Assembly, 120V/60Hz

XC-563-OV XC-563 Meter Console, with optional Orsat Pump Assembly, 240V/50Hz

XC-563 Source Sampler Console

Features • Precision Gas Meter with LCD Totalizer• Module with Dual Pressure Transducers• Digital Probe Temperature Control/Display• Vacuum Gauge (Dual Scale)• Stainless Steel Quick Connects and Control Valves• Digital Temperature Display (oF or oC) with up to 6 Type-K Inputs• Non-Reversible External Pump Connections• Removable Front Lid and Back Panel• Digital Display for P Velocity Pressure, and H Orifice Pressure• No Messy Manometer Fluid• Digital Elapsed Timer• Lightweight

Specifications

Umbilical Connections:Electrical: 4 conductor circular connector grounded shell.

Sample Line: Stainless Steel 1/2” Quick Connectors.

Pitot Line: Stainless Steel 1/4” Quick Connectors (optional 3/8”).

External Pump: Stainless Steel 3/8” Quick Connect.

Thermocouples: Type-K Standard Size.

Power: 120V / 60Hz Standard

240V / 50Hz Optional

dimensions: 23” x 21” x 12” (58cm x 53cm x 30.5cm)

Weight: 39 lbs. (17.7 kg).

Sample Pump: Accepts Standard Method 5 Pump Assemblies.

Gas Meter: AP25, 0.7 liters per revolution, digital gas volume total-izer with Quadrature Encoder, 8 digit LCD display, 1cc resolution.

Temperature Control: Digital temperature controllers for probe and oven 1/32 DIN with solid-state relays.

Temperature display: Type-K 3.5 Digit LED display (°C is standard for export). °C/°F selectable via plastic jumper behind front bezel, -105°C to 1372°C range. (-157°F to 1999°F). Separate 7-channel TC selector switch. Standard and Metric Units.

digital Pressure Transducers for h P +/-2.5” range 0.01” resolution

+/-63mm range 0.1mm resolution H 0” - 5” range 0.01” resolution 0” - 127mm range 0.1mm resolution

(Bi-Directional)

Audit Kit for Digital Metering Console. ak-563audit kit

dhM-M100 - Handheld Meriam Manometer

INCLUdES:

Sh-32 - 8 x 10 Molded Plastic Case

SCL-F4 - Plastic Quick-Turn (Luer Lock)

SYR-30ML-LL dhM-M100

Sh-32

SCL-F4SYR-30ML-LL - Syringe, Luer Lock Tip, 30ml with 1 ml Increments

Page 12: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

11

ISOKINETIC SOURCE SAMPLING EQUIPMENT

Features• Rugged lightweight case with Molded-In Handle

• Precision Dry Gas Meter with Digital Display

• Minihelic Pressure Gauge

• Internal Diaphragm Pump

• Digital Temperature Display with up to 5 Type-K Inputs (°F)

• All Stainless Steel Fittings and Control Valves

• Digital PID Probe Temperature Controller

• Digital Elapsed Timer (hr:min:sec)

• Vacuum Gauge (Dual Scale)

• Easy Access for Service

METhOd 4 SOURCE SAMPLING CONSOLEThe Apex XC-40 Source Sampler Console is a durable, lightweight meter console ideal for Method 4 (Determination of the Moisture Content of Stack Gas). The meter console can be used with standard impingers and accessories to collect moisture for required calculations. This unit heats the stack probe and with its internal pump pulls 0.75 cfm as required to comply with Method 4.

XC-40 Source Sampler

See more information on our Method 4 Condenser Assemblies and Accessories for use with theXC-40 Source Sampler Console.

Method 4 Determination of the Moisture Content of Stack Gas Summary: Stack gas is extracted at constant rate (less than 21lpm) for a minimum volume of 600 liters. Moisture is scrubbed from the sample stream and measured volumetrically or gravimetrically.

Specifications

Gas Meter: Model AP25, 0.7/rev., digital gas volume totalizer, with Quadrature Encoder, 8 digit LCD Display, 1cc resolution.

Flow Indicator: Mechanical Orifice w/Minihelic Pressure Gauge, range (0-2”) or (0-50MM H2O).

Temperature display: Type-K 3.5 Digit LED display (°C is stan-dard for export). °C/°F selectable via plastic jumper behind front bezel, -105°C to 1372°C range. (-157°F to 1999°F).

Probe Temperature Control: Compact, 1/32 DIN autotuning indicating temperature controller with separate 25 amp solid state relay. 115 VAC outlet 5-15R, Type-K jack for input.

Internal Sample Pump: Single cylinder oil-less pump, long life diaphrams, 1/8-27 NPT Connections, Max. vacuum 23” hg, Min. full load speed 2800 rpm, nominal free flow 1.15cfm, 12V 3.8 amps

Vacuum Gauge: Dual Scale, 0 to 30” Hg and 0 to 100kPa.

Power: 115V/60Hz; 240V/50Hz (optional).

Sample Inlet: 1/2” Stainless Steel Quick-Connect (alternate sizes available)

dimensions: HxWxD: 21” x 9.5” x 14” (53 cm x 24 cm x 35.5 cm)

Weight: 22 lbs (9.98kg)

Model descriptionXC-40 Standard Metering Console with Digital Gas Meter, plus

Digital 8 digit LCD Totalizer. -.001 cu.ft. res. (120V/60Hz)

XC-40-V Standard Metering Console with Digital Gas Meter, plus Digital 8 digit LCD Totalizer. -.001 cu.ft. res.(240V/50 Hz)

XC-40M Metric Metering Console with Digital Gas Meter and a 8 digit Digital LCD Totalizer. 1cc res. (120V/60Hz)

XC-40M-V Metric Metering Console with Digital Gas Meter and a 8 digit Digital LCD Totalizer. 1cc res. (240V/50 Hz)

Method 4 Source Sampler Console

Method 4 Condenser Assemblies, Page 33

Page 13: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

12

ISOKINETIC SOURCE SAMPLING EQUIPMENT

The open tubular steel frame is designed for the meter console to sit on top of the pump frame. For easy maneuverability, an optional wheeled handle assembly is available. For use with XF version sample pump assembly.

XF-05HW Optional Pump FrameHandle Assembly. Black Tubular Steel with 8” Wheels

XF-05HW

METHOD 5 PUMP ASSEMBLIES

Lubricated Rotary Vane Pump (0523)The Lubricated Rotary Vane Pump includes two 5’ wire-reinforced, kink-free hoses with nonreversible quick connects. The pump is mounted in either the new, improved, stronger tubular steel frame, or the standard x-case with removable covers providing easy access for service. The wick style lubricator requires less maintenance. Option “V” added for 240V.

Specifications• Motor: 1/4hp, 120/240V 60/50Hz 4.6/2.3 Amp., RPM 1725/1425• Measured Flow: 3.1 cfm@ 1 inch Hg; 1.5 cfm@ 15 inches Hg • Maximum Vacuum: 25.5” Hg• Weight: 35 lbs., (16kg)

XE-0523

XE-0523 Pump Shown with Console

Model Description

XE-0523 Rotary Vane Pump in a Molded X-Case (120V/ 60 Hz)

XE-0523-V Rotary Vane Pump in a Molded X-Case (240V/ 50Hz)

XE-0523 Rotary Vane Pumps

XF-0523

Model Description

XF-0523 Rotary Vane Pump in Tubular Steel Frame (120V / 60 Hz)

XF-0523-V Rotary Vane Pump in Tubular Steel Frame (240V / 50Hz)

XF-0523 Rotary Vane Pumps

Model Description

E-0523 External Pump Assembly (std), Vane Pump, Open Aluminum Frame, Lubricator, 5ft Pwr Cord & Hoses,Stainless Quick Connects Standard, 120V

E-0523-V External Pump Assembly (std), Vane Pump, Open Aluminum Frame, Lubricator, 5ft Pwr Cord & Hoses, Brass Quick Connects Standard, 240V

E-0523 Open Aluminum Pump Frame

Page 14: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

13

ISOKINETIC SOURCE SAMPLING EQUIPMENT

XE-DAA

Model Pump

XE-DAA Double Headed Diaphragm Pump in a Molded X-Case, 110V/60Hz

XE-DAA-V Double Headed Diaphragm Pump in a Molded X-Case, 220V/50Hz

XE-DAA Pumps Diaphragm Pumps

XF-DAA Pump Shown with Console and XF-05HW Optional

Pump Frame

XF-05HW Optional Pump FrameHandle Assembly. Black Tubular Steel with 8” Wheels.

XF-05HW

XF-DAA

Model Pump

XF-DAA Double Headed Diaphragm Pump in Tubular Steel Frame, 110V/60Hz

XF-DAA-V Double Headed Diaphragm Pump in Tubular Steel Frame, 220V/50Hz

XF-DAA Diaphragm Pumps

Double Headed Diaphragm Pump (DAA)The Double Headed Diaphragm Pump will never require any lubrication. Pump is easy to service within its frame and includes a power cord, two 5’ wire-reinforced, kink-free hoses with non-reversible stainless steel quick connects (this pump is not recommended for use in extremely cold environments).

METHOD 5 PUMP ASSEMBLIES

Specifications• Motor: 1/2hp, 120V/60Hz, 5 1/2 Amp• Measured Flow: 2.9 cfm@ 1 inch Hg; 1.4 cfm@ 15 inches Hg • Maximum Vacuum: 26.5” Hg• Weight: 30 lbs., (14kg)

*See Accessories for Spare parts

Model Pump

E-DAA External Pump Assembly (alt), Double Diaphragm Pump, Open Frame, 5ft Pwr Cord & Hoses, 120V

E-DAA-V External Pump Assembly (alt), Double Diaphragm Pump, Open Frame, 5ft Pwr Cord & Hoses, S.S. Quick Connects Standard, 240Volt

E-DAA Open Aluminum Pump Frame

Page 15: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

14

ISOKINETIC SOURCE SAMPLING EQUIPMENT

NOZZLES FOR ISOKINETIC SAMPLING Apex Instruments offers Button-Hook Nozzles in multiple materials. The size needed for isokinetic sampling depends on the stack gas velocity; the material depends on the stack temperature andthe sampling method. The most popular nozzles are constructed from seamless 316 stainless steel and can be coated with FEP or SilcoSteelCR®. Other nozzle materials include Borosilicate Glass, Alloy 600 and Quartz. Standard sampling nozzles are 4”long and have a 5/8” o.d. shank for attaching to theprobe union. Stainless steel nozzles are configured with an O-Ring to aid in positive leak checks. A bored out union is needed with Apex O-Ring nozzles, although a standard union can be used if the O-Ring is removed. Other sizes and configurations are available. Nozzles must be measured before initial use. Glass and Quartz Nozzles are available with a female 14/35 ground glass taper joint eliminating the need for the 5/8” union. For use with male taper joint probe liners.

Unique to Apex Instruments, the Nozzle Shank has integrated Ferrule with O-Ring Groove. O-Ring (O-O14V) shown.

Nozzle Sets come in stainless steel, glass, quartz, inconel or FEP lined. Includes a Nozzle Case, Seven Nozzles, (sizes 4, 6, 8, 10, 12, 14, 16) and select Accessories.

Nozzle Sets

Nozzle w/ Female 14/35 Taper Joint

Size

-�

Standard I.D. Stainless Steel NS-�

Alloy 600

NI-�

FEP Lined

Stainless Steel

NST-�

Glass NG-�

Quartz NQ-�

Glasswith

Taper Joint

NG-�T

Quartz with

Taper Joint

NQ-�T

Silico Coated

Stainless Steel

NSIL-�Inch Decimal mm

4 1/8 0.120 3.048 5 5/32 0.152 3.861 6 3/16 0.180 4.572 7 7/32 0.209 5.309 8 1/4 0.245 6.223 9 9/32 0.277 7.05610 5/16 0.305 7.74711 11/32 0.334 8.48412 3/8 0.370 9.39813 13/32 0.402 10.2114 7/16 0.430 10.9215 15/32 0.459 11.6616 1/2 0.495 12.5717 17/32 0.527 13.3918 9/16 0.568 14.4

Individual Nozzles

Apex Instruments Threaded Nozzle Set (NS-TH-SET) features the larger ID nozzles for low stack gas velocity and a buttonhook Nozzle Blank (NS-THB) with a tapered fitting. The set includes seven SS Nozzle Tips that thread onto the Nozzle Blank. Sizes include 5/8”, 11/16”, 3/4”, 13/16”, 7/8”, 15/16” and 1”.

ns-th-set

Oversized Nozzles

Note: When using O-Ring, a Bored Union, (P/N: N-10UB) is required.

NS-SET

NG-SET

Model DescriptionNS-SET Stainless Steel Nozzles. Includes Four

5/8” Tube Nuts, O-Viton RingsNG-SET Glass Nozzles. Includes Three 5/8”

Glass Filled PTFE FerrulesNI-SET Alloy 600 Nozzles, with Inconel Tube NutNQ-SET Quartz Nozzles (Order Ferrules

Separately)NST-SET FEP lined, Stainless Steel Nozzles,

Includes Four 5/8” Tube Nuts, O-Viton Rings

NSIL-SET Silica Coated Stainless Steel Nozzle Set

Nozzle Sets

Size Nominal I.D. Stainless Steel

NS-TH� Inch Decimal mm20 5/8 0.625 15.87522 11/16 0.6875 17.46224 3/4 0.750 19.05 26 13/16 0.8125 20.63728 7/8 0.875 22.22530 15/16 0.9375 23.81232 1 1.0 25.4B Blank

Oversized Nozzles

Call For Additional Information

Page 16: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

15

ISOKINETIC SOURCE SAMPLING EQUIPMENT

Model Description (Standard 5/8”)N-10 5/8” Stainless Steel Tube Nut

NI-10N 5/8” Alloy 600 Tube Nut

N-10TG 5/8” Glass Filled PTFE Tube Nut

Model Description (Standard 5/8”)N-10BR Thrust Backer Ring, 5/8” for O-Ring

Seal, Stainless Steel. For use with O-113V

O-113V Viton® 5/8” O-Ring to seal liner (for use with N-10BR)

O-113V-DZ Viton® 5/8” O-Ring to seal liner (for use with N-10BR), Dozen

O-014V Viton O-Ring for 1/2” UltraTorr Fitting when Adapting to 1/4” UltraTorr Fitting

O-014V-DZ Viton® O-Ring for 1/2” UltraTorr Fitting when Adapting to 1/4” UltraTorr Fitting, Dozen

Model Description (Standard 5/8”)N-10 5/8 inch Stainless Steel Tube Nut.

N-10TG 5/8 inch Glass Filled Teflon Tube Nut, 12 flats (sided) Fits Unions and Ball Adapters

N-10UB Stainless Steel Union, Bored Out, with Nuts and Ferrules

N-10US Stainless Steel Union, Bored Straight Through, with Nuts and Ferrules

N-10UBT Stainless Steel union, Bored Out, PTFE Coated, with Nuts and Ferrules

N-10UST Stainless Steel, Bored Straight Through, PTFE Coated, with Nuts and Ferrules

NI-10UB Alloy 600, 5/8” Tube Union Bored Out, with Nuts and Ferrules

NI-10US Alloy 600, 5/8” Bored straight through, with Nuts and Ferrules

N-10USIB 5/8” Silcosteel®-treated Stainless Steel Bored Union, Nuts and Ferrules included

NTG-10U Glass Filled 5/8” PTFE Tube Union with Nuts and Ferrules

NTG-10UNN Glass Filled PTFE Tube Union without Nuts and Ferrules, Body Only

Material Max TemperatureStainless Steel 650°C (1200°F)PFA Fittings 177°C (350°F)Borosilicate Glass 480°C (900°F)Inconel 980°C (1800°F)Quartz 900°C (1650°F)Viton® O-Rings 260°C (500°F)Graphite Ferrules 980°C (1800°F)Glass Filled PTFE 315°C (500°F)Hastelloy C276 980°C (1800°F)

Recommended Maximum Temperatures

Nozzle AccessoRies

Model Description

NB-3 3/16” Diameter, Twisted Stainless Steel Wire and Nylon Bristles

NB-5 5/16” Diameter, Twisted Stainless Steel Wire and Nylon Bristles

NB-8 1/2” Diameter, Twisted Stainless Steel Wire and Nylon Bristles

NBT-1/2 PTFE Nozzle Brush, 1/2” Diameter, PTFE Barrel and Bristles

Nozzle Brushes

Nozzle Brush set (NB-seT) One of each type brush from three popular sizes in a convenient carrying tube (sizes 3, 5, & 8).

Model DescriptionVPC-4-16 1/4” Vinyl Push-On Cap, 1/4” OD,

1” Inside Height, Red

VPC-6-16 3/8” Vinyl Push-On Cap, 3/8” OD, 1” Inside Height, Red

VPC-8-16 1/2” Vinyl Push-On Cap, 1/2” OD, 1” Inside Height, Red

VPC-10-16 5/8” Vinyl Push-On Cap, 5/8” OD, 1” Inside Height, Red

Vinyl Nozzle caps Great for Leak Checks!

Rings

Nozzle Unions

Model Description (Standard 5/8”)10FF-S Stainless Steel, Front Ferrule

10FB-S Stainless Steel, Back Ferrule

10F-GR Graphite High Temp, Single Ferrule

10F-GR-DZ Graphite High, Temp, Ferrule (12 pc) Dozen

NTG-10F Glass Filled PTFE, Single Ferrule

NTG-10F-DZ Glass Filled PTFE, Ferrule (12 pc) Dozen

NI-10FF Alloy 600 Front Ferrule

NT-10BF Alloy 600 Back Ferrule

NT-10F PTFE Single Ferrule 5/8”

NT-10F-DZ PTFE, Single Ferrule, 5/8”, (12 pc) Dozen

Ferrules

NBT-1/2

Tube NutsIndividual Components can be Ordered Separately. Please Call for Pricing.

Integrated Ferrule on Stainless Nozzle for Steel Only

0-113V

N-10 N-10UBNN PL-[_]

PS-[_]N-10BR

(Welded)

IntegratedFerrule

Nozzle installation for steel Alloys.

Nozzle Installation for Glass and Quartz. Nozzle installation for Glass and Quartz.

N-10N-10UBNN

PL-[_] [_]

NB-SET

Includes 5/8” Bored Union Body, Nut, Ferrules, Backer Ring and Viton® O-Rings. PK-SP

small Parts Kit

Page 17: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

16

ISOKINETIC SOURCE SAMPLING EQUIPMENT

Standard Method 5 Probe

Method 5 Probe with Optional Oversheath

Optional OversheathPacking GlandPG-32S

STANdARd METhOd 5 hEATEd PROBESThe Apex Instruments Standard Method 5 Heated Probe Sheath feature 1” diameter sheaths constructed from corrosion resistant stainless steel, modular 3/8” pitot tip, 1/4” stainless steel quick connects, Type-K thermocouples for stack & probe temperature, probe heater and an orsat line, small parts package. Standard lengths are 3’ to 16’. Longer lengths and custom orders are available by request. Order probe liners separately. Probes are ordered according to nominal (liner length). Effective length is one foot less than nominal length.

Replace � with Nominal Length (feet)

Stainless Steel Probe Sheath + Heater PS-�H

Optional with 2” OD Probe Oversheath

PS-�HO2�

Replacement Heater PH-�

Watt

3 3504 3505 4006 4007 4008 4509 475

10 50011 55012 60014 60016 700

Probe Sheaths & heaters

Add “V” to end of part number for 240V option at no extra cost.

The unique design of the Apex Modular Pitot Tip reduces the collection of water droplets in the pitot lines. The lower tube is self-draining while the offset in the upper tube acts as water trap.

Replacement Pitot TipsProduct DescriptionMPT-6-133 Type S Modular Pitot Tip for Oversheath Probes, 3/8”

Stainless Steel, 133mmMPT-6-181 Replacement Pitot Tip for Standard Method 5 Probe Assemblies,

3/8” SS, 181mmMPT-6-181-OFF

Replacement Pitot Tip, 3/8”, Stainless Steel, Offset for use with 47mm Filter holder and PM2.5 Cyclone, 181mm

MPT-6-218 Replacement Pitot Tip, 3/8”, Stainless Steel, Extended for use with Method 5 nozzle and SFA-47 In-Stack filter, Length 218mm

MPT-6-283 Replacement Pitot Tip,3/8”, Stainless Steel, extended for use with PM10 Cyclone and 47mm In-Stack Filter, Length 283mm

MPT-6-320 Replacement Pitot Tip, 3/8”, Stainless Steel, Extended for use with standard Method 5 nozzle and SFA-190, SFA-300, or SFA-2590 In-Stack Filters, Length 320mm

MPT-6-421 Replacement Pitot Tip, 3/8”, Stainless Steel, Extended for use with PM10/2.5 Cyclones and SFA-47 In-Stack Filter, Length 421mm

- 1 foot shorter then effective

Features a tightly wound heating element around a rigid tube. The rigid tube design allows liner replacement without removing the heating element. Actual tube length is 2-3/8” less than nominal length. Apex probe heaters are designed to operate at the method 5 specified temperature of 245°F (+/-25 Degree F). Specify alternate temp requirement if needed at the time of order. The maximum recommended temperature is 260°C (500°F). In extreme applications (probe heaters over 11 feet, long u-cord, long power extension cord), power drops may occur. In these instances, a separate temperature controller is suggested. See Gas Analysis Section, Page 9 for Apex ICH-901 Temperature Controller. Alternate wattage requirement to be specified at time of order.

Method 5 Probe (Tube) heaters

PG-32S

2” Oversheath Packing Gland, 2” NPT Threads, Stainless Steel with PTFE Ferrule. Must be Specified at time of order.

pg-32s

Packing Gland (Optional)

length in mm

M

‘S’ type pitots manufactured in accordance with U.S. EPA Reference Method 2 may be assigned a baseline coefficient of 0.84. Geometric and wind-tunnel calibrations are offered:

PT-CAL-G (Geometric Certification)PT-CAL-W (Wind Tunnel Calibration)

-1 foot shorter then effective

Call For Additional Information

Page 18: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

17

ISOKINETIC SOURCE SAMPLING EQUIPMENT

Part Number DescriptionGA-28B10TG PTFE Adapter Glass filled, 28mm Ball to 5/8 inch Tube Fitting, Straight Probe

Liner Ball Adapter. Includes PTFE/glass nut, ferrule and Viton® O-RingGA-28B10TGNN PTFE Adapter Glass filled, 28mm Ball to 5/8 inch Tube Fitting, No Nut

PROBE LINERSStandard Probe Liners are constructed from 5/8” diameter tubing and have #28 ball joint attached. Liners are available in borosilicate glass, quartz, stainless steel, Alloy 600 and PFA; liners with integrated nozzles require a ball joint adapter. Glass and quartz liners with male 14/35” taper joint are available for attaching to the nozzle, eliminating the need for the 5/8” union.

Monorails, page 52

Length in Feet

Standard Probe Liner

Tubing

Probe Liner with Male 14/35 Taper Joint and #28 Ball Joint

Probe Liner with Nozzle(shown with optional #28 ball adapter)

GA-28B10TG

PLN- GTor

PL- QT

N - T

PLS- GN Specify Nozzle Size

Quartz or Glass 14/35 TaperSize

TubingSeamless, for use as probe liner (plain ends)

Part Number DescriptionTTG-10/6 Glass Filled PTFE Probe Liner Material, 5/8 inch OD, 3/8 inch IDTPFA-10/6 Tubing PFA, 3/8 ID x 5/8 OD Heavy WallTS10-035S Seamless 316 Stainless Steel Tubing, 5/8” OD x .035 Wall TI10-035S Seamless Alloy 600 Tubing, 5/8” OD x .035 Wall

MaterialReplace �

with Nominal Length (feet)

Glass

PLN-�G

Stainless Steel

PL-�S

QuartzPL-�Q

Alloy 600

PL-�I

C-276 PL-�C

GT

PLN-�GTQT

PL-�QT

3456789

1011121416

Probe Liners

Call for Pricing on PLS- GN

*See Accessories for Isokinetic Software

Isokinetic Slide RuleThis device performs Isokinetic Stack Sampling Calculations. The slide rule provides new ∆H settings at a glance.

M5A-1.......English Units

M5A-1M....Metric Units

Programs included: • Traverse Points Location• Stack Gas Velocity and Volumetric Flow Rate• Stack Gas Moisture Content• Stack Gas Saturation Moisture Content• Ideal Nozzle Size and K-Factor with ∆H Loop• Post-Test Isokinetics• DGM Field Calibration using Critical Orifices

m5a-C

ISOKINETIC CALCULATORS & SPREAdShEET

M5A-C

Isokinetic M5A-C CalculatorThe Casio Graphic Scientific Calculator comes pre-programmed with valuable Isokinetic stack sampling calculations making field calculations quick and easy. Programmed in English and metric units.

Special OptionsPTFE

Adapters

Call For Additional Information

Page 19: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

18

ISOKINETIC SOURCE SAMPLING EQUIPMENT

AIR COOLEd METhOd 5 PROBE

Alloy Method 5 Probe Sheaths are for hot corrosive gases. Includes a 3/8” pitot tip, 1/4” stainless steel quick connects, stack temperature thermocouple with magnesium oxide insulation, and orsat line. The Alloy probe sheaths come standard with Alloy 600 unions for nozzle and pitot (stainless steel optional). Order liners separately. Alternate alloys available, please call for more information and for pricing.

SPECIAL ALLOY METhOd 5 PROBE ShEAThS

Call for current pricing for the following items:• Alloy Liners (PL-��I) • Alloy Sheaths (IPS-��)

- Recommended for High Temperature Applications - Highly Corrosion Resistant

BlowersSBR Blower Assembly, variable speed 93 cfm, connects to SB-2M, also includes hose (110V/60Hz). Add “V” for 240V option.

sBr-93CFm

sBr-93CFm-V

Glass and Quartz Liners Not Recommended Due to Breakage

Part

NumberNominal

Length (feet)APS-4I 4

APS-6I 6

APS-8I 8

Air Cooled Method 5 Probe Assembly with unheated alloy 600 Liner

Call for pricing on additional lengths.

SB2M

SB3

SBR-93CFM

Air Cooled Probe

Air flow in air cooled probes.

Add “V” to end of part number for 240 V at no extra cost.

Air Cooled Method 5 Probes up to 8’ in length, applicable for high temperature sources. Concentric tubular design allows the cooling air to return and exhaust out of the stack. The probe sheath is constructed from stainless steel tubing while the liner, pitot, thermocouple and nozzle union are made from inconel. A variable speed high capacity blower is needed for cooling. Order blower separately.

Page 20: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

19

ISOKINETIC SOURCE SAMPLING EQUIPMENT

MOdULAR SAMPLE CASE ASSEMBLIESApex Instruments Modular Sample Case Assemblies are versatile, lightweight and available in a variety of configura-tions. There are three different filter ovens, and two different risers that can attach to the bottom of the ovens, with four different impinger cases. The impinger cases slide on and off for easy changing of the impinger sets between test runs. Several standard assemblies are available or the individual components can be purchased separately. Please inquire for additional details.

Model description

SB-50 Modular Sample Case Assembly, Includes Miniature Heated Filter Box SB-2M, Riser SBR-10, and Impinger Box SB-3 (holds 4 impingers), 120 V

SB-50-V Modular Sample Case Assembly, Includes Miniature Heated Filter Box SB-2MV, Riser SBR-10, and Impinger Box SB-3 (holds 4 impingers), 240 V

SB-50/4 Modular Sample Case Assembly, Includes Miniature Heated Filter Box SB-2M, Riser SBR-10, and MId-Sized Impinger Box SB-4 (holds 6-8 impingers), 1`0 V

SB-50/4-V Modular Sample Case Assembly, Includes Miniature Heated Filter Box SB-2M-V, Riser SBR-10, and Mid-Sized Impinger Box SB-4 (holds 6-8 impingers), 240 V

SB-50 Modular Sample Case Assembly

SB-2 heated Filter Box

SB-3

SB-1 Classic Modular Sample Case Assembly Model description

SB-1 Modular Sample Case Includes SB-2 Heated Filter Box & SB-3 Impinger Box, 120V

SB-1V Modular Sample Case (Includes SB-2V Heated Filter Box & SB-3 Impinger Box), 240V

SB-1/4Modular Sample Case Includes SB-2 Heated Filter Box, 110 VAC and SB-4 Impinger Box, holds 6-8 impingers

SB-1/4V Modular Sample Case, includes SB-2 V Heated Filter Box, 240V and SB-4 Impinger Box, holds 6-8 impingers

Heated Filter Box Standard Features• Lightweight aluminum construction• Stainless Steel Probe Clamp• Type K Thermocouple Jack• Probe and Auxiliary Power Jacks• 500 Watt Heater (750 Watt Optional)• 1/2 inch E-Glass Insulation• Mounting Hardware for Riser• Double Doors• Handle/Monorail Attachment• Aluminum Liner• Stainless Steel Latches• Internal Reinforcement

Rigid Arrangement

Monorails, page 52

Flexible Arrangement

SBR-10SB-3

SB-2M Miniatureheated Filter Box

Page 21: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

20

ISOKINETIC SOURCE SAMPLING EQUIPMENT

FILTER OVENSFilter ovens have lightweight powder-coated aluminum-lined panels with stainless steel clamps, hardware and E-Glass insulation thermal insulation. Internal reinforcements reduce flexing of box when testing with long probes. Front and rear doors provide greater accessibility. The handle is designed for attaching to a monorail for easy traversing. The 1” probe clamp may easily be removed from the oven and replaced with differ-ent alternative probe clamps. A SBR-10 Riser is for mounting the impinger case in the rigid arrangement. The SB-2 is the traditional full-size filter oven that is designed for the rigid arrangements for accommodating a cyclone before the filter. The SB-2M Miniature Filter Box and SB-2 Filter Oven will accept standard 2”, 3”, and 4” filter assemblies.

Classic Full Size heated Filter Box has 2 access doors, probe clamp and accepts cyclone. 120 V/60 Hz standard. Dimensions: 23.5” x 9.5” x 9.5”, (60 x 24 x 24 cm), Weight: 16 lbs (7.3 kg).

Add “V” to end of part numberfor 240V/50Hz at no extra cost.

sB-2

sB-2VSB-2

STRAIN RELIEFS FOR SB-2M

GA-104

GA-107-12

The GA-104 connects a 3/8” sample line to the filter exit of the SB-2M oven. Standard comes with #28 socket, thermo-couple, and 1/2” to 3/8” reducing union.

ga-104

The GA-107 strain relief is used with sample lines at the SB-2M during Flexible Method 5 sampling. Includes bracket that attaches to the SB-2M and standard mount with clamp. 1/2” tube.

ga-107-12

The GA-113 strain relief is used spe-cifically with heated sample lines at the SB-2M during Flexible Method 5 sampling. Includes bracket that attaches to the SB-2M and an adjustable Velcro® strap to grip heated sample lines.

ga-113 GA-113

Model description

PC-1 Probe Clamp for 1 inch OD Probe Assemblies

PC-1VU Vertical Probe Clamp for Up-Traverses, 1 inch Clamp

PC-1VD Probe Clamp for Down-Traverse, 1 inch Clamp

PC-2/32 Probe Clamps for 2” Bevel Packing Gland

SB-2M-ST Straight Through Heated Filter Box has two access doors and probe clamp. The Apex SB-2M-ST is the SB-2M with the probe clamp raised so an in-line filter assembly can be used without the need for the cyclone bypass. In addition #28 Stainless Steel Socket with a 3/8” full flow quick-connect is installed on the outlet. Accepts filter assembly GNFA-3-STR. Dimensions: 13.5” x 9.5” x 9.5”, (34.3 x 24 x 24 cm), Weight: 10 lbs (4.5 kg) 120V/60 Hz standard. Add “V” to end of part number for 240V/50 Hz at no extra cost.

sB-2m-st

sB-2m-st-V

SB-2M Miniature heated Filter Box has two access doors and probe clamp; 120V/60 Hz standard. Dimensions: 13.5” x 9.5” x 9.5”, (34.3 x 24 x 24 cm), Weight: 10 lbs (4.5 kg).

sB-2m

sB-2m-V

Add “V” to end of part number for 240V at no extra cost.

SB-2MShown with GA-104 Strain Relief. Order Separately

SB-2M-STSB-2M-ST-V

GA-108

Stainless Steel #28 Socket Adapter with Full Flow 3/8” quick connect and Mounting Bracket, Used on SB-2M Straight Thru To Attach Sample Line.

ga-108

Page 22: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

21

ISOKINETIC SOURCE SAMPLING EQUIPMENT

Model Description

SB-50 Modular Sample Case Model 50, (includes SB-2M, SBR-10, & SB-3 & probe clamp), 120V

SB-50-V Modular Sample Case Assembly, Includes Miniature Heated Filter Box SB-2M-V, Riser SBR-10, PC-1, and Impinger Box SB-3, 220V

SB-50/4 Modular Sample Case Assembly, Includes Miniature Heated Filter Box SB-2M, Riser SBR-10, PC-I, and MId-Sized Impinger Box SB-4 (holds 6-8 impingers), 110V

SB-50/4-V Modular Sample Case Assembly, Includes Miniature Heated Filter Box SB-2M, Riser SBR-10, PC-1, and MId-Sized Impinger Box SB-5, 220V

SB-50/5 Modular Sample Case Assembly, Includes Miniature Heated Filter Box SB-2M, Riser SBR-10, PC-I, and MId-Sized Impinger Box SB-5, 110V

SB-50/5-V Modular Sample Case Assembly, Includes Miniature Heated Filter Box SB-2M, Riser SBR-10, PC-1, and MId-Sized Impinger Box SB-5, 220V

Model Description Holds Impingers Dimensions (HxWxD) Weight

SB-3 Impinger Box/Insulated Coolant Reservoir; Model 100 4 9.5” x 9.5” x 13.5” (24.1 cm x 24.1 cm x 34.3 cm) 5 lbs (2.3 kg)

SB-4 Impinger Box/Insulated Coolant Reservoir; Model 150 6 12.5” x 9.5” x 13.5” (31.8 cm x 24.1 cm x 34.3 cm) 6 lbs (2.7 kg)

SB-4SD Impinger Box/Insulated Coolant Reservoir; Divided; Model 150 4 12.5” x 9.5” x 13.5” (31.8 cm x 24.1 cm x 34.3 cm) 6 lbs (2.7 kg)

SB-5 Impinger Box/Insulated Coolant Reservoir; Model 200 8 16” x 9.5” x 13.5” (40.6 cm x 24.1 cm x 34.3 cm) 7 lbs (3.2 kg)

SB-8

GA-100UA-3J

SB-3

Power Box AdapterThe UA-3J connects to umbilical 4-pin circular connector and converts to three straight blade receptacles. Clamps to 1/2” sample line or GA-100 adapter. The UA-3J is used in conjunction with the Compact Method 5, Method 8, Method 17 and in other sampling situations in which power for the probe is not available due to the absence of a heated filter box.ua-3J

Impinger Inlet Strain ReliefThe GA-109 strain relief is used with sample lines at the impinger box when performing Flexible Method 5 sam-pling. Includes bracket that attaches to the impinger box and standard mount with sample line clamp (specify size). Available from 3/8” tube to 2” or 3”.-S is for Velcro version.

ga-109-12ga-109-s

UA-3J-V Adapter, Power,U-Cord, 3 receptacles, 220V Power Box Adapter, Includes 1/2 inch Mounting Clamp and 4 Pin Amphenol to 3 Receptacles.ua-3J-V

UA-3J

UA-3J-VGA-109-12

Sample Case Risers attach to the base of the filter oven for test methods requiring extra height between the filter outlet and the first impinger. The SBR-10 Riser is required for attaching the impinger case to the SB-2M for rigid arrangements. SBR-18 Riser is primarily used for Method 23 sampling when using a vertical condenser.

RISERS

IMPINGER CASES (COLd BOXES)

MOdULAR SAMPLE CASE FRAMEThe Modular Sample Frame (SB-8) with Probe Clamp is an ideal addition for sampling methods that require no heated filter compartment such as Method 8, Method 306 and in-stack filtration methods. The SB-8 secures the probe and impinger case in a rigid manner. The sample frame is made of durable powder coated aluminum with stainless steel probe clamp and impinger case slides.

sB-8

Apex offers four different removable Sample Box Impinger Cases. These cases are constructed from a thicker aluminum to reduce cracking, durable polyethylene foam insulation, and pre-punched foam insert for holding the impinger bottles in place, and have a fold down handle with a rope centering guide and two high strength brackets for mounting strain relief. The cases slide on and off the heated filter box for easy changing of the impingers between test runs. All cases are equipped with a spring-loaded latch to prevent accidental slippage.

SB-3 SB-4 SB-4Sd SB-5Impingers Cases

Model Description Dimensions (HxWxD) Weight

SBR-10 Riser for SB-2M, impinger box adapter, 10” riser with insulated reservoir 9.5” x 9.5” x 10” (24.1 cm x 24.1 cm x 25.4 cm) 10 lbs (4.5 kg)

SBR-18 Riser for MM5, impinger box adapter, 18” riser with insulated reservoir 9.5” x 9.5” x 18” (24.1 cm x 24.1 cm x 45.7 cm) 10 lbs (4.5 kg)

Umbilical (Gooseneck) AdapterThe GA-100 connects the final impinger outlet to the umbilical cable. Standard with #28 socket, thermocouple and 1/2” stainless steel male quick connect. Mounts on Impinger box.ga-100

GA-100

SBR-10 SBR-18

Page 23: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

22

ISOKINETIC SOURCE SAMPLING EQUIPMENT

GN-9A GN-9AO

GN-1GNFA-3

GN-8-18K

GN-2Cyclone Body

(optional)

GN-3Cyclone Flask

(optional)

O-116V #28 Ball Viton® O-Ring

O-126V Impinger Taper Viton®, O-Ring, Top

O-123V Impinger Taper Viton®,

O-Ring, Bottom

GN-11

GN-9A GN-9A

ISOKINETIC GLASSWARE SETSBASIC GLASSWARE SETS Apex Instruments offers a complete line of glassware. Our Standard Glassware features extra heavy borosilicate glass with unground #28 Ball and Socket Joints with O-Ring Seals. Cost effective unground joints are more durable than ground joints and the O-Rings provide a tight, leak-free seal without grease. This set includes all the glassware necessary for one train.

Model DescriptionGN-CGS Basic Method 5 Glassware Set

(3” Filter Assembly)GN-CGS4 Basic Method 5 Glassware Set

(4” Filter Assembly)GN-CGS-Z Basic Method 5 Glassware Set

(3” Filter Assembly) with OZ style ClampsGN-CGS4-Z Basic Method 5 Glassware Set

(4” Filter Assembly) with OZ Style Clamps

Qty Part # Description1 GN-1 Cyclone Bypass, Unground with O-Ring

1 GNFA-� Filter Assembly, Unground Glass, PTFE Frit, Open Style Aluminum Clamp, 3” or 4”

1 GN-8-18K Double “L” Adapter with Type K Thermocouple Assembly, Cap and Silicone Seal

1 GN-9AO Greenburg Smith Impinger with Orifice, Unground

3 GN-9A Modified Greenburg Smith Impinger, Plain, Unground

3 GN-11 U-Tube, Unground Sockets

12 BS28WS #28 Ball Joint Clamp, Generic

Basic Method 5 Glassware Sets

Includes:

Qty Part Description1 GN-8 Double L Adapter, Unground #28 Sockets1 GN-9AO Greenburg Smith Impinger with Orifice, Unground3 GN-9A Modified Greenburg Smith Impinger, Plain, Unground3 GN-11 U-Tube, Unground Sockets10 BS28WS #28 Ball Joint Clamp, Generic

Method 4 Glassware Sets Model DescriptionGN-CG4 Basic Method 4 (Moisture) Glassware Set

Includes:

Alternative Styles and Filter AssembliesAre also Available.

Page 24: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

23

ISOKINETIC SOURCE SAMPLING EQUIPMENT

dELUXE METhOd 5 GLASSWARE SET WITh TRANSPORT CASE

NOTE: Set does not include cyclone or cyclone flask. Spare O-Rings are included.

Case dimensions: 25” (63.5 cm) x 19” (48.2 cm) x 23” (58.4 cm)

Full Weight: 63 lbs. (29 kg.) Empty Weight: 39 lbs. (18 kg.)

dELUXE METhOd 5 GLASSWARE SET The deluxe Method 5 Glassware Set with Transport Case (GN-dGS) contains all the glassware plus spares for a full test series. Four filter assemblies cover three sampling runs plus one as a spare. Two full sets of impingers and U-Tubes permit a second run before recovering the first run results. The deluxe glassware set includes spare impingers, U-tubes and Double “L” adapters. The glassware set fits easily into foam lined custom pockets. The sturdy transport case is lockable for secure chain-of-custody. Optional FEP Encapsulated O-Rings are available upon request.

Model Description

GN-DGS Deluxe Method 5 Glass Set w/ Transport Case (3” FA)

GN-DGS4 Deluxe Method 5 Glass Set w/ Transport Case (4” FA)

deluxe Method 5 Glassware Set

Qty Part Description

1 TC-GW2.5 Glassware Transport Case

4 GN-1 Cyclone Bypass, Unground with O-Ring

4 GNFA-� Filter Assembly, Unground Glass, PTFE Frit, Open Style Aluminum Clamp. - Specify Size 3” or 4”

2 GN-8 Double “L” Adapter, Unground Sockets

2 GN-8-18K Double “L” Adapter with Type K Thermocouple Assem-bly, Cap and Silicone Seal

3 GN-9AO Greenburg Smith Impinger with Orifice, Unground

7 GN-9A Modified Greenburg Smith Impinger, Plain, Unground

8 GN-11 U-Tube, Unground Sockets

30 BS28WS #28 Ball Joint Clamp, Generic

1 GA-3P Filter Tripod

30* O-116S Silicone O-Ring for Grooved #28 Ball

10* O-123V Bottom Viton® O-Ring for Impinger Insert

10* O-126V Top Viton® O-Ring for Impinger Insert

deluxe Method 5 Glassware Set Includes:

* Spares

#28 Ball Joint Sockets are Standard.

Ball Joint Clamps

GLASSWARE ACCESSORIES

Caps & Seals

Product DescriptionO-116V-DZ Viton® O-Ring for

grooved #28 ball, dozenO-116T-DZ TFE Encapsulated

Silicone O-Rings for grooved #28 ball, dozen

O-123V-DZ Viton® O-Ring for bottom groove in Impenger Stem Joint, Dozen

O-126V-DZ Viton® O-Ring for top groove in Impenger Stem Joint, Dozen

#28 Ball Joint & Taper Joints Seals

Product DescriptionBS28WS #28 Stainless steel

ball joint clampRC-29 #28 Stainless steel

ball joint clamp, Pyrex brand

KBS-29 Keck Clip,#29, plastic ball joint clamp

Product Description

GA-GL-18B Bored Cap with hole, #18 threads

GA-18C Solid Cap without hole, #18 threads

GA-GL-18S #18 Silicone Seal Ring, 50 Durometer#18 Threads, 6.5mm Hole Diameter

GA-GL-18ST #18 Silicone with PTFE Seal Ring, #18 Threads,6.5mm Hole Diameter, w/PTFE on half

GA-GL-18T6 #18 Threads Silicone Seal Ring 6.5mmHole Diameter with PTFE on half

GA-GL-18T8 #18/8 PTFE Seal Ring

GA-GL-18/9 #18 Silicone Seal Ring, with PTFE 9 mm to 11 mm

Page 25: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

24

ISOKINETIC SOURCE SAMPLING EQUIPMENT

GLASSWARE FILTER ASSEMBLIES & COMPONENTS

Filter Media, page 46-47

4” Unground Glass, PTFE Filter support, OZ Style Threaded Filter Clamp.

gnFa-4Z

Model Description

GN-2S 2” Glass Filter Inlet, #28 Unground Socket, 90 Degree Bend

GN-2B 2” Glass Filter Outlet, #28 Unground O-Ring Ball

GA-2CA 2” Aluminum Filter Clamp, Open Plate Style

GA-2T 2” PTFE Filter Support with Viton® O-Rings

O-138T FEP Encapsualted O-Ring for GA-2T

O-138V Viton® O-Ring for GA-2T

GA-2P 2” Nylon Filter Tripod

3” Unground Glass, PTFE Filter Support, Open Style Aluminum Clamp.

gnFa-3

4” Unground Glass, PTFE Filter Support, Open Style Aluminum Clamp.

gnFa-4Model Description

GN-4S 4” Glass Filter Inlet, #28 Unground Socket, 90 Degree Bend

GN-4B 4” Glass Filter Outlet, #28 Unground O-Ring Ball

GA-4CA 4” Aluminum Filter Clamp, Open Plate Style

GA-4CZ 4” Single Thread Filter Assembly, OZ Style

GA-4T 4” FEP Filter Support with Viton® O-Rings

O-156T FEP Encapsulated O-Ring for GA-4T with Hollow Silicone Core

O-156V Viton® O-Ring for GA-4T

GA-4P 4” Nylon Filter Tripod

2” Filter Components (55mm)

4” Filter Components (110mm)

Open Style Aluminum Clamp, U-Style with90o inlet and outlet, and #18 threaded joint.

gnFa-3u-18

3” Unground Glass, PTFE Filter Support, Open Style Aluminum Clamp, Straight Through Style.

gnFa-3-str

4 inch Filter Assembly, Unground Glass, Poly Donut Spacer with TC assembly, Dual PTFE Frits, Open Style Aluminum Clamp.

gnFa-4-5g

2” Unground Glass, PTFE Filter Support, Open Style Aluminum Clamp.

gnFa-2

2” U-Style Unground Glass, with 90° inlet & outlet, PTFE Filter Support, Open StyleAluminum Clamp.

gnFa-2u

3” Unground Glass Filter Support, OZ Style Threaded Filter Clamp.

gnFa-3Z

Kit with Thermocouple Assembly.

gnFa-3u-18k

Model Description

GN-3S 3” Glass Filter Inlet, #28 Unground Socket, 90 Degree Bend

GN-3SS-S 3” Glass Short Stem, Straight Inlet with #28 Unground Socket

GN-3B 3” Glass Filter Outlet, #28 Unground O-Ring Ball

GA-3CA 3” Aluminum Filter Clamp, Open Plate Style

GA-3CZ 3” Single Thread Filter Clamp Assembly, OZ Style

GA-3T 3” PTFE Filter Support with Viton® O-Rings

GA-3SS 3” Machined Stainless Steel Filter Support Disk with Viton® O-rings, Accepts 82.6 mm filter

O-152T FEP Encapsulated O-Ring for GA-3T

O-152V Viton® O-Ring for GA-3T

GA-3G 3” Glass Filter Disk with Rubberized Edge

3” Filter Components (82.6mm)

3” Glass Filter Disk with Rubberized Edge.

ga-3g

3” Stainless SteelFilter Support Disk.

ga-3ss

3” Filter PTFE Disk with Viton O-rings.

ga-3t

Page 26: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

25

ISOKINETIC SOURCE SAMPLING EQUIPMENT

INdIVIdUAL GLASSWARE ANd ACCESSORIESApex Instruments offers a complete line of glassware featuring Extra Heavy Borosilicate Glass with unground #28 ball and socket joints with O-Ring seals. Unground joints are more durable and price effective than ground joints and the O-Rings provide a tight, leak-free seal without grease. Standard GN-Series Glassware includes Unground O-Ring joints and double O-Ring 45/50 taper joints.

IMPINGER ASSEMBLIES (BOTTLES WITh INSERTS)

GN-9A GN-9AK GN-9AO-M7GN-9AO

403mm15.867in

Model DescriptionGN-9A Modified Greenburg-Smith

(plain stem), 500 ml

GN-9AO Greenburg-Smith (stem with orifice and plate), 500 ml

GN-9AK Knock-out (short stem), 500 ml

GN-9AO-M7 Method 7 (stem with restricted orifice), 250 ml

CYCLONESModel DescriptionGN-2 Cyclone Body, #28, unground

socket and O-Ring ball

GN-3 Cyclone Flask, #28 unground sockets

GN-2RH Cyclone for Mini Hot Box, Reduced Height, includesTeflon-lined #30 Cap

GN-3GN-2 GN-2Rh

Model DescriptionGN-9I Modified Greensburg-Smith O-Ring balls

(plain stem), unground taper joint with double O-Ring seals

GN-91O Greenburg-Smith (orifice stem), O-Ring ball, unground taper joint with double O-Ring seals

GN-91K Knock-out stem, O-Ring balls, unground taper joint with double O-Ring seals

GN-9I

GN-9IK

GN-9IO

387mm15.0 in

INSERTS

Model DescriptionGN-9B Bottle, unground taper joint, 500 ml,

330 mm x 57 mm

GN-9B-1 1.0 liter, 330 mm x 75 mm

GN-9B-1.5 1.5 liter, 330 mm x 100 mm.

GN-9B-2 2 liter, 330 mm x 110 mm

GN-9B-4 4 liter, 330 mm x 140 mm

GN-9B-M7 Method 7 Bottle, 250 ml, accepts GN-9I. 330 mm x 38 mm

BOTTLES

380 mm.13.0 in.

Page 27: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

26

ISOKINETIC SOURCE SAMPLING EQUIPMENT

GFA-2590N-CC

GFA-2590N-CCSUse with these Connections

GFA-2590B-CC

GN-8-18K

GN-1 GN-11 GN-13 GN-8

CONNECTORS

Model DescriptionGN-1 Cyclone Bypass, #28 unground socket and O-Ring BallGN-1-18 #18 Thread for TC (no cap or TC) (not shown)GN-8 Double “L” with #18 Thread for TC. Order

cap and seal separatelyGN-8-18 Double “L” with #18 Thread for TC. Order

cap and seal separatelyGN-8-18K Double “L” withType-K TC assembly,

cap and silicone sealGN-11 U-Tube, #28 unground socketsGN-13 Filter By-Pass, #28 unground socket and O-Ring ball

Glass Cap #28 unground socket.

gn-16

Glass Plug, #28 unground ball with Vitron® O-Ring.

gn-17

Balls and Caps

INdIVIdUAL GLASSWARE ANd ACCESSORIES

Product DescriptionGFA-2590N-CCS GFA-2590 Insert Straight-Thru with

Unground #28Socket to Male Taper Joint, Connects directly to probe. Linear distance socket to taper start 2.5 inches.

GFA-2590B-CC Body for Controlled Condensate Method with ground #28 Ball on outlet

GFA-2590N-CC Insert with “S” Offset, Unground #28 SocketGFA-2590B-CC Body for Controlled Condensate Method with

ground #28 Ball on outletGN-HCCH-A Horizontal Condenser, CCS, Assembly #28

Controlled Condensate Sampling with #11 port for inserting cartridge heater, with Heater and TC assembly, #28 Socket both ends, Water Jacket w/Hose Barbs, TC-well and # 15 Solid Cap

Controlled Condensate Glassware

Page 28: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

27

ISOKINETIC SOURCE SAMPLING EQUIPMENT

Model DescriptionGN-20B4 #28 unground O-Ring ball to 1/4” tube

GN-20B6 #28 unground O-Ring ball to 3/8” tube

GN-20B8 #28 unground O-Ring ball to 1/2” tube

GN-20B10 #28 unground O-Ring ball to 5/8” tube

GN-19 #28 unground O-Ring ball to #22 thread. Order cap and seal separately

AdAPTERS

GN-20BGN-18 GN-18B GN-19 GN-20S

Method 17 Glassware

Product DescriptionGFA-2590N* Nozzle Insert, Glass for

GFA-2590 In-StackFilter Assembly, Specify Nozzle Size (N4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 16, 18, 20)

GFA-2590 Thimble Filter, 25x90mm,Binderless Glass Fiber,Tapered, 10/box

GFA-2590B Filter Body, Glass, for GFA-2590 Filter Assembly, 5/8” shank

Product DescriptionG-47N 4 Nozzle I.D. 1/8”

G-47N 5 Nozzle I.D. 5/32”

G-47N 6 Nozzle I.D. 3/16”

G-47N 7 Nozzle I.D. 7/32”

G-47N 8 Nozzle I.D. 1/4”

Product DescriptionG-47N 10 Nozzle I.D. 5/16”

G-47N 12 Nozzle I.D. 3/8”

G-47N 14 Nozzle I.D. 7/16”

G-47N 16 Nozzle I.D. 1/2”

Glass Filter Inlet, 47 mm, with Attached Nozzle

CONdENSERS

Product Description

VGC-9A Condenser Assembly-Includes #7 and #11nylon caps with o-rings and PTFE ferrules.

VGC-12A Condenser Assembly-Includes black nylonbushings, caps o-rings and PTFE ferrules.

INdIVIdUAL GLASSWARE ANd ACCESSORIES

VGC-12AVGC-9A

Model DescriptionGN-18 #28 unground socket to hose barb

GN-18B #28 unground O-Ring ball to hose barb

GN-20S4 #28 unground socket to 1/4” tube.

GN-20S6 #28 unground socket to 3/8” tube

GN-20S8 #28 unground socket to 1/2” tube

GN-20S10 #28 unground socket to 5/8” tube

GFA-2590N GFA-2590BGF-2590 G-47N

Page 29: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

28

ISOKINETIC SOURCE SAMPLING EQUIPMENT

Product DescriptionGNM-HC Horizontal Condenser, #28 Unground Sockets, Water Jacket Hose Barbs.

GNM-HC-18 Horizontal Condenser, #28 Socket both ends, Water Jacket with Hose Barbs with #18 GL joint for monitoring condenser outlet temperature.

GNM-HC-18F Horizontal Condenser, #28 Socket both ends, #18 joint for monitoring Filter Outlet temperature, Water Jacket with Hose Barbs, Glass Type K thermocouple assembly NOT included.

GNM-T XAD Trap, #28 Unground Socket & O-Ring Ball (Top), Water, Jacket Hose Barbs.

GN-9AKS Knock-Out Impinger Assembly, Unground (for Horizontal MM5)

GN-9AKSA Knockout Impinger Stem - 24/40 Taper Short Male, UsedBefore Purge on MTHD 202.

Method 23 Glassware

GNM-hCGNM-hC-18F

GNM-hC-18

Product DescriptionGN-VCHM-M202 M202 Spiral Condenser, #28 Socket

both ends Water Jacket Hose Barbs, High Moisture sources above 15%

GN-9AKS Knock-out Impinger Assembly, Unground, (for HorizMM5)

GNFA-3U-18K 3 inch Filter Assembly, Unground Glass with 90 degree Inlet & Outlet, Open Style Alum Clamp & TC

Method 202 Glassware

INdIVIdUAL GLASSWARE ANd ACCESSORIES

Product DescriptionGN-9AKSA Knockout Impinger Assembly - 24/40 Taper Unground (for HorizMM5),

Included with Long / Short Stem.

GN-9AKSB Knockout Impinger Bottle - 24/40 Taper Unground (for HorizMM5),Used with Long / Short Stem.

GN-9AKSI Knockout Impinger Stem - 24/40 Taper Short Male, UsedBefore Purge on MTHD 202.

GN-9AKSIL Knockout Impinger Stem - 24/40 Taper Long MaleUsed for Purge on MTHD 202.

GNM-T

GN-9AKSGN-9AKSA

GN-9AKSA

GN-VChM-M202

GN-9AKSIL

GN-9AKSI

GN-9AKSB

GN-9AKS

GNFA-3U-18K

Page 30: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

29

ISOKINETIC SOURCE SAMPLING EQUIPMENT

BALL ANd SOCKET JOINT AdAPTERSGlass-Filled PTFE

PFA FittingsApex offers both Straight and Elbow PFA Fittings with 1/4” NPT for 1/4”, 3/8” and 1/2” tubing and a ball joint with a 5/8” tube union for adapting to plain probe liners. PFA (Perfluoro-alkoxy) fittings are chemically inert and highly corrosive resistant. Higher mechanical strength than PTFE at elevated temperatures (to 500O).

Apex offers Glass-Filled PTFE #28 Ball and Socket Adapters. Glass fiber fillers are added to Virgin PTFE to improve upon the mechanical properties. Adapters are resistant to deformation under a heavy load and will significantly improve the performance of the seal during a test. Glass-filled adapters are tapped for 1/4” NPT fittings.

Glass Filled PTFE#28 Ball to 1/4” Female NPT

ga-28B4ntg

Glass Filled PTFE#28 Socket to 1/4” Female NPT

ga-28s4ntg

Glass Filled PTFE#28 Socket to 3/8” Tube Fitting(Includes Nylon Nut & PTFE Ferrule)

ga-28s6tg

Probe Liners, page 17

Glass Filled PTFE#28 Ball to 5/8” Tube Fitting(Includes glass Nut, Ferrule and Viton® O-Ring)

ga-28B10tg

Glass Filled PTFE Ferrules5/8” Glass Filled PTFE Ferrule

ntg-10F

5/8” Glass Filled PTFE Ferrule, Dozen

ntg-10F-dZ

Glass Filled PTFE NutGlass Filled PTFE 5/8” Tube Nut

n-10tg

Glass Filled PTFE UnionTube Union, 5/8” Body Only

ntg-10unn

Glass Filled PTFE Union5/8” Union (includes nuts and ferrules)

ntg-10u

PFA Straight Connectors:

PFA Elbow Connectors:

3/8” Tube Fitting to 1/4” MNPT6msC4n-pFa

1/2” Tube Fitting to 1/4” MNPT8msC4n-pFa

1/4” Tube Fitting to 1/4” MNPT4msC4n-pFa

1/2” Tube Fitting to 1/4” MNPT8msel4n-pFa

1/4” Tube Fitting to 1/4” MNPT4msel4n-pFa

3/8” Tube Fitting to 1/4” MNPT6msel4n-pFa

Page 31: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

30

ISOKINETIC SOURCE SAMPLING EQUIPMENT

Stainless Steel Impingers and Accessories are manufactured with #28 Ball and Sockets, 2” diameter and a 500ml capacity. Stainless Steel Impingers are interchangeable with glass impingers for many applications. This kit includes an impinger with Double “L” Inlet Stem, one impinger with restricted inlet U-Stem, two impingers with plain inlet U-Stem, straight inlet stem, five #28 ball joint clamps.

Stainless Steel Ball Adapters#28 Ball to 1/4” FNPTga-28B4n

Stainless Steel Socket Adapter#28 Socket to 1/4” Tube Fittingga-28s4

#28 Socket to 1/4” FNPTga-28s4n

#28 Socket to 3/8” Tube Fittingga-28s6

#28 Socket to 1/2” Tube Fittingga-28s8

#28 Socket to 5/8” Tube Fittingga-28s10

BALL ANd SOCKET JOINT AdAPTERSApex Instruments offers Stainless Steel #28 Ball and Socket Adapters in a variety of sizes, used for connecting to rigid or flexible sample lines. The #28 Ball includes O-Ring (O-116V).

Model Description

S-9A6 Impinger Bottle, 500 ml, 2” diameter, 3/8” Tube Unions, Q-Clamp, No Stem, Stainless Steel

S-9AL Impinger Double “L”, Inlet Stem and #28 Socket and Ball with, Stainless Steel

S-9AO Impinger with Restricted Inlet U-Stem, #28 Socket and Ball, Stainless Steel

S-9A Impinger with Plain Inlet U-Stem, #28 Socket and Ball, Stainless Steel

S-9IL Double “L” Inlet Stem, #28 Socket with Plain End, Stainless Steel

S-9IS Straight Inlet Stem, #28 Ball with Plain End, Stainless Steel

S-9IR U-Stem Inlet, #28 socket on 3/8” Tube with Restricted Tip, Stainless Steel

S-9I U-Stem Inlet, #28 socket on 3/8” Tube with Plain Tip, Stainless Steel

S-9IT Stem Outlet, #28 Ball with O-Ring on 3/8” Tube, Stainless Steel

S-9C2 2” Q-Clamp with Wing Nut, Stainless Steel

40MPU-2 For 2” Q-Clamp, Gasket Buna

S-9B Impinger Bottle Only, 500 ml, Stainless Steel

STAINLESS STEEL IMPINGERS ANd ACCESSORIES

Stainless Steel Impingers and Accessories

#28 Socket 3/8” Elbow Tube Fitting ga-28s4el6

Stainless Steel Socket & Elbow Adapter

Double “L” with #28 Sockets and 1/4” Union for Thermocouple. (TCA-6X24).s-8-4

Stainless Steel Double “L” Connector U-Tube connector with #28 Sockets.s-11

Stainless Steel U-Tube Connector

1/4” Tube Fitting to 1/4” MNPT4msC4n-s3/8” Tube Fitting to 1/4” MNPT6msC4n-s1/2” Tube Fitting to 1/4” MNPT8msC4n-s

1/4” Tube Fitting to 1/4” MNPT 4msel4n-s3/8” Tube Fitting to 1/4” MNPT6msel4n-s1/2” Tube Fitting to 1/4” MNPT8msel4n-s

Stainless Steel Male Elbow Connector

Stainless Steel Straight Adapter

s-8-4kDouble “L” Adapter w/Thermocouple Kit

S-9I

S-9B

S-9IT

S-9IS

S-9IL

BS28WS

S-9AL S-9AO S-9A S-9ATHE SECOND IMPINGER HAS A RESTRICTOR

AT THE BASE OF THE STEM.

See Page 23 for Ball Joint Clamps

Fitting SizeTube Union

4N=NPT (Female)

Set of 4 Stainless Steel Impingers - Stainless Steel Impinger Condenser Assembly, #28 Socket & Ball, Methods 4, 5 and 17. S-5CN

Page 32: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

31

ISOKINETIC SOURCE SAMPLING EQUIPMENT

UA-FP

UA-HJ

SPlit BAck UmBilicAl cABleSplit Umbilical Cables replace Standard Umbilical Cords for added versatility. They are constructed the same way as the Standard Method 5 umbilicals with the sample line and exit thermocouple split to the specified length. Split umbilicals are useful in flexible systems when the filter compartment is separated from impinger box with a flexible sample line such as Method 17, Flexible Method 5 set-ups and Compact Method 5. The umbilical lengths are specified according to overall length. Stainless steel quick connects are standard.

clASSic UmBilicAl cABleS Are lightweight with braided cover. The easily repaired umbilical cable includes one kink-free, wire reinforced sample line, 3 kink-resistant polyethylene lines (2 pitot & 1 orsat line), 6 type K thermocouple extensions, and five conductor electrical cable with 4-pin circular connectors. Thermocouple plugs are colored coded. The sample line has 1/2 inch quick connect and the pitot lines have 1/4 inch quick connects standard (3/8 inch optional). Standard lengths are 30, 60 and 90 feet. U-bag included.

classic Umbilical cordModel DescriptionU-30 30’, Method 5, 1/4” Pitot Quick Connects, Stainless Steel Quick ConnectsU-60 60’, Method 5, 1/4” Pitot Quick Connects, Stainless Steel ConnectsU-90 90’, Method 5, 1/4” Pitot Quick Connects, Stainless Steel Quick Connects

Model DescriptionU-BAG Large Canvas Bag with straps and logoQS4/6 Stainless Steel Quick Connects 1/4” Male, 3/8” Female Pitot Quick ConnectsQS6 Stainless Steel Quick Connects 3/8” Male and Female Pitot Quick Connects

Optional Accessories

Split Umbilical cables

clASSic UmBilicAl Power Box Adapter (UA-3J)The UA-3J connects to umbili-cal 4-pin circular connector and converts to three straight blade receptacles. Clamps to 1/2 inch sample line or GA-100 adapter. The UA-3J is used in conjunction with the Compact Method 5, Method 8, Method17 and in other sampling situations in which power for the probe is not available due to the absence of a heated filter box.

UA-3JUA-3J-V

Probe Power Adapter (UA-HJ)Connects to umbilical 4-pin circular connector and converts to a single female receptacle for the probe power.

UA-HJ

Heated Filter Box Power Adapter (UA-FP)The UA-FP connects with male plug to the 4-pin circular connector on the filter oven and allows the oven to connect to a standard receptacle.

UA-FP

Heated Filter Box Power Adapter (UA-FP2)Heated Filter Box Power Adapter, Includes one (1) 4 Socket Amphenol to two (2) Male Standard 120V Plugs

UA-FP2

UA-3J UA-3JV

Split -Back Umbilical Cord

Aux

Exit

Sample 1/2” QCStack

To Meter Console

Orsat

Pitot 1/4” QC Probe

Filter

Oven

Amphenol

6 connectors

Filter

Split Umbilical cord

Model DescriptionUS-30-10 30’ Umbilical w 10’ Split 1/4” Pitot Quick Connects,

Stainless Steel Quick ConnectsUS-60-10 60’ Umbilical w 10’ Split 1/4” Pitot Quick Connects,

Stainless Steel Quick ConnectsUS-90-10 90’ Umbilical w 10’ Split 1/4” Pitot Quick Connects,

Stainless Steel Quick ConnectsAlternate Lengths Available, Call for Pricing

Umbilical cord Bag

U-BAG

Large Canvas Bag with straps and logo

Page 33: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

32

ISOKINETIC SOURCE SAMPLING EQUIPMENT

Unheated Sample Line jumpers are used between the filter and the first impinger in “flexible” sampling arrangements. Jumpers are available in various lengths and configurations. Stainless steel overbraid 3/8” ID PFA tubing is standard.

UNhEATEd SAMPLE LINES

Unheated Sample Line

hEATEd SAMPLE LINES (JUMPERS)

heated Sample Line Jumper

Add “V” to end of part number for 240V at no extra cost.

STRAIN RELIEFMini heated Filter Box Sample Line Strain ReliefThe GA-107 strain relief is used with sample lines at the SB-2M during Flexible Method 5 sampling. Includes bracket that attaches to the SB-2M and standard mount with sample line clamp (specify size).

Model DescriptionGA-107-9 Line Adapter (for SB-2M), includes Bracket and 3/8 inch ID Sample Line Clamp

GA-107-12 Line Adapter (for SB-2M), includes Bracket and 1/2 inch ID Sample Line Clamp

GA-107-32 Line Adapter (for SB-2M), includes Bracket and 1-1/4 inch ID Sample Line Clamp

GA-107-50 Line Adapter (for SB-2M), includes Bracket and 2 inch ID Sample Line Clamp

GA-107-57 Line Adapter (for SB-2M), includes Bracket and 2-1/4 inch ID Sample Line Clamp

Heated Sample Line Jumpers are used when source sampling site has limited access and insufficient space for a traditional, rigid sample train. Apex Instruments manufactures short heated sample lines/jumpers for use between the probe and the heated filter assembly or between the probe and the first impinger inlet. Temperature Controller Required.

USL-�-SSTConnects to the

SB-2M

USL-�-QSTConnects to the SFA-82h

USL-�-SSConnects to Probe Liner

Impinger

The GA-113 strain relief is used specifically with heated sample lines at the SB-2M during Flexible Method 5 sampling. Includes bracket that attaches to the SB-2M and an adjustable Velcro® strap to grip heated sample lines.

GA-113

HSL-�-� HSRL- � Diameter of each sample or cal gas tubing (4 = 1/4”, 6 = 3/8”, 8= 1/2”) - � Length of line in feet

HSL-6-10 10’, 3/8” PFA Sample Line, with Insulation & Protective Sleeve, 120V, ~ 20 Watts / Per Ft.HSL-6-15 15’, 3/8” PFA Sample Line, with Insulation & Protective Sleeve, 120V, ~ 20 Watts / Per Ft.HSL-6-20 20’, 3/8” PFA Sample Line, with Insulation & Protective Sleeve, 120V, ~ 20 Watts / Per Ft.HSL-6-25 25’, 3/8” PFA Sample Line, with Insulation & Protective Sleeve, 120V, ~ 20 Watts / Per Ft.HSL-6-10V 10’, 3/8” PFA Sample Line, with Insulation & Protective Sleeve, 240V, ~ 20 Watts / Per Ft.HSL-6-15V 10’, 3/8” PFA Sample Line, with Insulation & Protective Sleeve, 240V, ~ 20 Watts / Per Ft.HSL-6-20V 20’, 3/8” PFA Sample Line, with Insulation & Protective Sleeve, 240V, ~ 20 Watts / Per Ft.HSL-6-25V 25’, 3/8” PFA Sample Line, with Insulation & Protective Sleeve, 240V, ~ 20 Watts / Per Ft.

heated Sample Lines/Jumpers

Model DescriptionUSL-�-� USL- � Length in feet / � SST (#28 socket elbow fitting) or QST

(1/2” quick connects/#28 socket elbow)USL-10-SST 10’ Unheated, PTFE/Stainless Steel Overbraid, w/Thermocouple Assembly,

#28 Stainless Steel, Socket Elbow FittingsUSL-10-SS 10’ Unheated Sample Line, 3/8PTFE/Stainless Steel

PTFE with SS overbraid, #28 Socket Elbow Fitting Both Ends USL-15-SST 15’ Unheated, PTFE/Stainless Steel Overbraid, w/Thermocouple Assembly,

#28 Stainless Steel, Socket Elbow FittingsUSL-25-SST 25’ Unheated, PTFE/Stainless Steel Overbraid, w/Thermocouple Assembly,

#28 Stainless Steel, Socket Elbow FittingUSL-10-QST 10’ Unheated, PTFE/Stainless Steel Overbraid, 1/2” Female Stainless

Steel Quick Connect, w/Thermocouple Assembly, #28 Stainless Steel Socket ElbowUSL-15-QST 15’ Unheated, PTFE/Stainless Steel Overbraid, 1/2” Female Stainless Steel

Quick Connect, w/Thermocouple Assembly, #28 Stainless Steel Socket ElbowUSL-25-QST 25’ Unheated, PTFE/Stainless Steel Overbraid, 1/2” Female Stainless Steel

Quick Connect, w/Thermocouple Assembly, #28 Stainless Steel Socket Elbow

GA-107-�GA-113

Page 34: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

33

ISOKINETIC SOURCE SAMPLING EQUIPMENT

METhOd 4 SAMPLING TRAIN

Flexible Method 4 Arrangement

Rigid Method 4 Arrangement

Method 4 Determination of the Moisture Content of Stack Gas Summary: Stack gas is extracted at constant rate (less than 21lpm) and a minimum volume of 600 liters. Moisture is removed from the sample stream, and measured volumetrically or gravimetrically.

sk-m4

sk-m4-V

Part DescriptionPC10-4S CEM IRM Probe, 4ft,

Stainless Steel Sheath,5/8” Stainless Steel Liner.

PLS-4S-QCF6 Probe Liner, 4ft, SS, w/Full Flow, 3/8” QC.

USL-15-QS 15ft Unheated Sample Line, PTFE with SS Overbraid, #28 Socket Elbow Fitting and Full Flow 3/8” QCF Elbow Fitting.

SB-8 Probe Clamp FrameGN-CG4 Method 4 Glassware Set,

Unground Joints.SB-3 Impenger box, Model 100,

Insulated Cooltant Reservoir, Holds 4 Impingers

GA-100 Sample Case AdapterUS4-25-10 U-Cord, Method 4, 25”,

Splitback 10ft.

Method 4 Individual Accessories

XC-40 Meter ConsoleRecommended for Method 4 Testing

Meter Consoles, page 4-11

Meter Console Sold Separately

Page 35: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

34

ISOKINETIC SOURCE SAMPLING EQUIPMENT

BASIC-PLUS METhOd 5For a source sampling company to get started sampling for particulates (U.S. EPA Reference Method 5), Apex recommends a combination of equipment that can be configured for both rigid and flexible set-ups.Select your METER CONSOLE (see page 8-10)Select your SAMPLE PUMP (see page 12 - 13)

sk-m5Bp

sk-m5Bp-V

Basic Method 5 Includes:• Stainless Steel Nozzle Set• 6-ft Probe with Heater• 1 Stainless Steel Probe Liner, 3 Glass Probe Liners• 30-ft Split U-Cord• 15-ft Unheated Sample Line• Hot & Cold Box Assembly with Riser• Sample Frame for Cold Box (Flexible Config.)• Strain Reliefs• Basic Glassware Set (1 sample run configuration)• Filter Paper• Brushes (Probe & Nozzle)• Calculator (programmed for Method 5)

dELUXE-PLUS METhOd 5The professional source sampling company must be prepared for a wide variety of con-ditions and locations. Apex recommends the “Deluxe Plus” system, which can be used in both rigid and flexible configurations. Even with the classic rigid arrangement, the ad-ditional glassware allows you to have pre-measured and filled impingers, pre-weighed filter assemblies, and minimum turnaround time between runs. The flexible arrange-ment is effective for challenging environments like vertical traverses and space-limited sources. After selection of a meter console and external sample pump, the Deluxe-Plus system provides all of the components listed in the above Basic-Plus system.

Schematic of Method 5 Flexible Sampling Train

Schematic of Method 5 Rigid Sampling Train

PLUS:• Glass Nozzle Set• 3-ft & 9-ft Probe Assemblies with • Stainless Steel & Glass Probe Liners• 60-ft Split U-Cord• 2.5 Sets of Glassware Plus Carrying Case• 4 Monorail Assemblies (9-ft & 12-ft)• Transport Case for a Meter Console• Calibrated Orifice Set

sk-m5dp

sk-m5dp-V

Page 36: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

35

ISOKINETIC SOURCE SAMPLING EQUIPMENT

COMPACT METhOd 5The Apex Compact Method 5 Sampler Kit features an independently Heated Stainless Steel Filter Assembly (SFA-82H) that connects directly to a standard Method 5 probe. It does not require a separate heated filter compartment, and utilizes a flexible sample line, and a split umbilical cord with power adapter, to allow sampling in space-limited areas. The standard glass impingers have been replaced with Stainless Steel Impingers (S-5CN) to eliminate glass breakage. Three filter assemblies are recommended to speed up the turn around time between consecutive runs. Add “V” to end of part number for 240V option at no additional cost.

sk-Cm5

sk-Cm5-V

STAINLESS STEEL hEATEd FILTER ASSEMBLYThe Apex Instruments Heated Stainless Filter Assembly (SFA-82H) is for sampling particulates from space-limited industrial sources. The filter assembly has a two piece threaded clamping ring with an integral 300 watt ring heater . A Viton® O-Ring seals the 82.6 mm filter and prevents sample bypass. It has stainless steel inlet, outlet and a PTFE filter support screen (GA-3T). The inlet plate comes with a 5/8” tube union for swaging directly to a plain probe liner. The outlet plate has 3/8” female NPT connection and a male 3/8” full flow quick connect. The mating female quick connects with the thermocouple, which is supplied with the Unheated Sample Line (USL-�-QST) or SFA-82-QCF6, may be ordered separately. There is a thermal insulated blanket supplied with each unit. An unheated version is also available without the integral heater and blanket. Add “V” to end of part number for 240V at no extra cost.

SFA-82 (unheated)sFa-82hsFa-82hVsFa-82-qCF6sFa-82-Bkt

SFA-82hDepending upon the source, it may be possible to combine

Method 5 and Method 8 into the same train.

SK-CM5 Kit• Heated Filter Assemblies (3)• Probe Sheath with Heater • Stainless Steel Probe Liner• Impinger Box • Impinger Inlet Strain Relief• 60’ Split Umbilical Cord• Unheated Sample Line with Stainless Steel Overbraid• Power Box Adapter • Umbillical Adapter • Stainless Steel Nozzle Set• Stainless Steel Impinger Assembly• PTFE Coated Glass Fiber Filters

Schematic of U.S. EPA Method 5 Compact Sampling Train

SFA-82-QCF6

SFA-82-BKT

Page 37: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

36

ISOKINETIC SOURCE SAMPLING EQUIPMENT

METhOd 5GMethod 5G Determination of Particulate Matter Emissions from Wood Heaters (Dilution Tunnel Sampling Location). The exhaust from a wood heater is collected with a total collection hood, and is combined with ambient dilution air. Particulate matter is withdrawn proportionally from a single point in a sampling tunnel and is collected on two glass fiber filters in series.

gnFa-4-5g

Components Include:4” Filter Assembly, Unground Glass #28 Ball/Socket, Poly Donut Spacer with ThermocoupleAssembly, Dual PTFE Filter Supports and Open Style Aluminum Clamp.

METhOd 5I The METHOD 5I SAMPLING KIT is similar to Basic Method 5, except for the addition of the 5I Holder (SGFA-47-5I) and is designed for the determination of low-level particulate matter (PM) emissions from stationary sources. Method 5I is most effective for PM catches less than 50 mg and is valid for performing correlation of manual PM measurements to PM con-tinuous emission monitors or determining PM emissions from low-level sources such as turbines. Add “V” to end of part number for 240V at no extra cost. After selecting a Method 5 Meter Console and an external sample pump in conjunction with a Method 5 kit, add a Method 5I Holder.

The 5I Filter Holder inlet is constructed of Borosilicate Glass to hold a 47mm glass fiber filter with a wafer-thin stainless steel filter support and a Viton® O-Ring. The assembly is wrapped with PTFE tape for weighing, averaging less than 35 grams, providing a positive seal against leakage. Method 5I 47mm Filter Assembly with Glass Inlet & SS Outlet, with 2 45 deg bends.

ALTERNATE METhOd 5I FILTER ASSEMBLY (Straight) Same Application as Method 5IStraight version of SGFA-47-5I, for use with SB-2M-ST, straight through heated filter box.

sgFa-47-5is

SGFA-47-5IS

SGFA-47-5I

GNFA-4-5G

Page 38: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

37

ISOKINETIC SOURCE SAMPLING EQUIPMENT

Controlled Condensate is an alternative to EPA Method 8 for determining sulfuric acid emissions. Sulfuric acid vapor or mist and the sulfur dioxide are separated, by controlling the condensation based on difference in dew points, and both fractions are measured separately by the barium-thorin titration method. Controlled condensation method is the primary sampling and analytical tool for quantifying sulfuric acid emissions from stationary sources. The method is based upon the selective condensation of sulfuric acid from a gas stream by means of a water cooled condenser. The major advantage of the condensation method is that it provides reliable reproducible SO3 and SO2 values with minimal interference from high SO2 concentrations. There are several versions of the method. Option “V” is added for 240V.

sk-CC

sk-CC-V

METhOd 8

Method 8 Sampling Kit

Part Description

SB-8 Sample Frame with Probe Clamp

UA-3J Power Box Adapter

GNFA-2U 2” Filter Assembly,Unground Glass with 90° Inlet and Outlet,Open Style Alum Clamp

METhOd 8 RECOMMENdEdACCESSORIES

CONTROLLEd CONdENSATEConditional Test Method CTM-13

Quartz Liner Available

Glass Liner

GFA-2590#-CC SB-2M-STCC

Sampling Kit Available

The Method 8 Sampling Kit is used with either the XC-522 or XC-572 Meter Console and an external sample pump for the determination of sulfuric acid mist and sulfur dioxide emissions from stationary sources. U.S. EPA Reference Method 8 was originally developed to test emissions from sulfuric acid plants but has been adapted to sample emis-sions from sulfur dioxide sources. Call for details on Flex-ible Arrangements. Add “V” to end of part number for 240V at no extra cost.

Schematic of EPA Method 8 Sampling Train

UA-3J

GA-100

SB-3SB-8

PS- H PLN- GGlass Lined Probe

Glass NozzleNG-

US- -10

Page 39: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

38

ISOKINETIC SOURCE SAMPLING EQUIPMENT

Schematic of EPA Method 17 Flexible Sampling Train

Schematic of U.S. EPA Method 17 Rigid Sampling Train

In Method 7C and 7d an integrated sample is passed through a series of full-size orifice impingers that contain an alkaline-potassium permanganate solution. The sample rate is between 400 and 500 cc per minute, normally three one hour samples are collected per test. The MC-623 is the console of choice, however, a low flow orifice adapter is offered for converting the XC-572 Method 5 source sampler console for low flow sampling. The Method 7C sample is analyzed colorimetrically and for Method 7D analysis is by ion chromatography. Please inquire for additional details. Add “V” for 220VAC option.

Ck-m7Cd

METhOd 7C and 7d

Model descriptionPC10-3G 3 ft CEM Probe Assembly, 5/8” Glass liner, 110 VAC

PLN-3G 3 ft Glass Probe liner, 5/8” OD with unground #28 grooved ball

GN-8 Double”L” Adapter, #28 unground sockets

GN-11 U-Tube, #28 unground sockets

GN-9AO-M7 Impinger Assembly, Stem with Orifice, 250 mL, unground O-ring joints

Method 7 Accessories

PC10-3G

GN-9AO-M7GN-9A

SB-3

GN-8GN-11

SB-8

Method 17 Sampling Kit Components Include:• In-stack Filter Assembly

• Glass Fiber Thimbles

• Method 5 Probe Sheath with Tube Heater

• Method 17 Probe Liner w/ 3/8” Full Flow Male Quick Connects

• Unheated Sample Line with PFA Over braid

• 30’ Split Umbilical Line

• Power Box Adapter

• Sample Case Adapter

• Impinger Inlet Strain Relief

• Impinger Box, Insulated Coolant Reservoir

• Stainless Steel Nozzle Set

• Stainless Steel Impinger Assembly

sk-m17psk-m17p-V

METhOd 17 PLUS (RIGId & FLEXIBLE)The Apex Instruments Method 17 Sampling Kit is a convenient package for sampling particulate matter. Multiple fitting arrangements and filter assemblies are available with an in-stack filter. Add “V” to end of part number for 240V at no extra cost.

GN-9A Impinger Assembly, Plain Stem, 500 mL, unground O-ring joints, modified Greenburg-Smith

GA-100 Umbilical Adapter (Gooseneck) , #28 Socket with thermocouple, mounting bracket, 1/2” Male quick connects

SB-3 Impinger Box/Insulated Coolant Reservoir Model 100, holds 4 impingers

SB-8 Modular Sample Frame with Probe Clamp and Impinger Box Slides

Page 40: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

39

ISOKINETIC SOURCE SAMPLING EQUIPMENT

SFA-4(Nozzles not included)

INTEGRATEd IN-STACK FILTER ASSEMBLY KIT The SGFA-47NK In-Stack Filter assembly kit features the unique design combination of borosilicate glass 47mm filter inlet with integrated nozzle, allowing the option to weigh the glass fiber filter media individually for Method 17 or very similar to Method 5I by weighing the combined nozzle, filter media with a support, O-Ring and PTFE Tape. The kit includes the standard array of seven nozzle sizes from 1/8” to 1/2”.

sgFa-47nk

METhOd 17 IN-STACK FILTER ASSEMBLIES

GLASS IN-STACK FILTER ASSEMBLIESThe Apex Instruments GFA-2590 Thimble Holder is constructed completely from borosilicate glass for use with Conditional Method for Ammonia (CTM-027) and accepts tapered 25 x 90mm thimbles, specifically manufactured for stack sampling. Does not require O-Rings, for testing at higher temperatures. The borosilicate glass withstands temperatures up to 480°C (900°F).

Nozzle Insert - Replace � with nozzle diameter. (Sizes 4-16). Call for additional sizesGFA-2590N�

Filter Body - 5/8” Glass Filter BodygFa-2590B

Metal Taper Joint Clamp - A durable nickel plated steel clip that securely holds the conical joint under pressure to withstand temperatures of up to 500°C (932°F).ktm-29

In-Stack Filter Assembly using a 47 mm diameter Filter Element.sFa-47

In-Stack Filter Assembly using 19mm x 90 mm Thimble Filter Element.sFa-190In-Stack Filter Assembly using 30mm x 100 mm Thimble Filter Element.sFa-300

In-Stack Filter Assembly using 25mm x 90mm Thimble Filter Element.sFa-2590

Inconel Version sFa-47inCo

Filter Inlet 47 mm Glass Filter Inlet with Integrated Nozzle. Replace � with nozzle diameter.

Part descriptionO-128V Viton® O-Ring for SFA-2590 (450 °F)

O-324S Silicone O-Ring for SFA-300 (500 °F)

O-324G Graphite O-Ring for SFA-300 (1000 °F)

O-324V Viton® O-Ring for SFA-300 (500 °F)

Q4213 Viton® Quad Ring for SFA-190 (450 °F)

O-223V Viton® O-Ring, 47 mm for SFA-47 (450 °F)

O-223H High Temperature Stainless Steel O-Ring for SFA -47

SF-TT20 PTFE Thrust Ring for SFA-47 Filter Assembly

O-324G Graphite O-Ring for SFA-300 (1000+ °F)

Replacement Seals

Filters and Thimbles, page 46

GFA-2590K In-Stack Thimble holder Kit - Includes a selection of the seven most commonly used nozzle inserts from 1/8” to 1/2” and one housing. Kit is conveniently packaged in a foam-lined carrying case for protection. The thimble holder connects directly to the end of the probe with a 5/8” tube union.gFa-2590k

Nozzle Size

GFA-2590N □ Nozzle Insert GFA-2590B

Filter Body

5/8” ShankKTM-29 CLIP

Product Glass Filter Inlet Integrated Nozzles

G-47N-ST 47 mm Glass Filter Inlet with ground #28 Socket on inlet

G-47N-4 47mm, with Attached Nozzle, Nozzle I.D. 1/8”

G-47N-5 47mm, with Attached Nozzle, Nozzle I.D. 5/32”

G-47N-6 47mm, with Attached Nozzle, Nozzle I.D. 3/16”

G-47N-7 47mm, with Attached Nozzle, Nozzle I.D. 7/32”

G-47N-8 47mm, with Attached Nozzle, Nozzle I.D. 1/4”

G-47N-10 47mm, with Attached Nozzle, Nozzle I.D. 5/16”

G-47N-12 47mm, with Attached Nozzle, Nozzle I.D. 3/8”

G-47N-14 47mm, with Attached Nozzle, Nozzle I.D. 7/16”

G-47N-16 47mm, with Attached Nozzle, Nozzle I.D. 1/2”

Call for Pricing of Quartz Components

Page 41: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

40

ISOKINETIC SOURCE SAMPLING EQUIPMENT

Schematic of Method 23Sampling Train

METhOd 23 dELUXE PLUSThe Apex Instruments Method 23 (Modified Method 5) Source Sampler Kit is utilized for Method 23 determination of dioxins and furans (D/F’s) and/or Method 0010 Determination of Semi-Volatile Organic Compounds. The sampling train is identical to the standard Method 5 system with the addition of a water-cooled glass condenser and an XAD absorbent module followed by a knockout impinger. Additional glassware configurations are available. Please call for information.

Select Meter Console and External Pump for M23 then add a kit. Add “V” to part number for 240V option at an additional cost.

sk-m23dp

sk-m23dp-V

Product Conversion Accessories

SB-4 Impinger Box/Insulated Coolant Reservoir Model 150, Holds 8 Impingers

MM5-P Submersible Coolant Pump, 120V

GNM-T XAD Trap, #28 Ball & Socket Joints, Unground

GN-16 Glass Cap #28 Socket, Unground, to Seal XAD Trap

GN-17 Glass Plug #28 Ball, Unground, to Seal XAD Trap

KBS-29 Clip, Knock, Plastic out Impinger, Unground

TL-7/5 Latex Tubing, 7/16 OD, 5/16 ID, Natural Color, Per Foot

Method 23 Individual Accessories

Product description

GNM-HC Horizontal Condenser, #28 Unground Sockets, Water Jacket, Hose Barbs

GNM-VC Vertical Condenser, #28 Unground Sockets, Water Jacket Hose Barbs

GNM-T XAD Trap, #28 Unground Socket nd O-Ring Ball (Top), Water, Jacket Hose Barbs

GN-9AKS Knock-Out Impinger Assembly, Unground (for Horizontal MM5)

Method 23 Glassware

Requirements:• Borosilicate Glass or Quartz Nozzles and Probe Liners are recommended.• Wrap XAD sorbent module with aluminum foil to shield from radiant heat and ultraviolet rays that dechlorinate the D/F isomers.• Sealing greases are not allowed. FEP O-Ring seals are recommended and may be required by some agencies.• Flexible train requires heated flexible sample lines.

Coolant Pump OptionsProduct Description

MM5-P Submersible Coolant Pump, 110V

MM5-PM Mini Submersible Coolant Pump, 110V

MM5-P220 Submersible Coolant Pump, 220V

MM5-P MM5-PM

M23 Sampling Train

Method 23 Source Sampler Kit Components:• 6’ Probe with Heater• Glass Probe Liners (3)• Glass Nozzle Set• Hot/Cold Box/Riser• 30’ Split-Back Umbilical • Glassware, Deluxe Set

• Horizontal Condensers (2)• XAD Traps (8)• Submersible Recirculating Pump• Probe and Nozzle Brushes• Programmed Calculator

Page 42: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

41

ISOKINETIC SOURCE SAMPLING EQUIPMENT

METhOd 26A – hCl

M26A Sampling Train

The Apex Instruments Method 26A Sampling Train is used for determination of hydrogen halide and halogen emis-sions. Method 26A is the isokinetic alternative to Method 26. This method is particularly suited for sampling sources controlled by wet scrubbers emitting acid particulate matter. The method requires a Method 5 sampling train with the use of additional impingers, reagents and PTFE coated glass fiber filter media. Please call for more information. Add “V” to end of part number for 240V at no additional cost.

Product Conversion Accessories

SB-4 Impinger Box/Insulated Coolant Reservoir Model 150, Holds 8 Impingers

NG-SET Set of 7 Glass Nozzles - Sizes 4,6,8,10,12,14&16, Includes Case and Three 5/8” Glass Filled PFA Ferrules

NBT-1/2 Nozzle Brush, 1/2” diameter, PTFE Bristles

PBX-10T 10 foot Flexible PTFE Probe Brush Extension, Brush not Included

PBT-5/8 PTFE Probe Brush Tip (PTFE Barrel and Bristles), 5/8 inch Bristle Diameter

GN-9AK Knock-Out Impinger, Short Stem, 500ml, Unground O-Ring Joints

GN-9AO Impinger Assembly, Stem with Orifice & Plate, 500ml, Unground O-Ring Joints, Greenburg-Smith

GF-3TPG 82mm PTFE Coated Glass Fiber Filters - Hydrophobic, Low absorption of acid gases such as SOX or NOX . 50/box (MFS PG60)

Method 26A Recommended Accessories

Schematic of Method 26A Sampling Train

When stack temperatures exceed 210oC (410oF) a one-piece glass nozzle/liner assembly is recommended.

Page 43: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

42

ISOKINETIC SOURCE SAMPLING EQUIPMENT

The METHOD 29 determination of metal emissions from hazardous waste incinerators involves a modification of the Method 5 train. The sampling train is the same as a Method 5 particulate train with the addition of up to three impingers to enhance the collection of metals of interest. The impinger train requires the SB-4 impinger case, glass nozzles, probe liners and non-metallic union. The method has been validated for the collection of 17 different metals.

Add “V” to end of part number for 240V option at no additional cost.

METhOd 29 – MULTIPLE METALS

Schematic of Method 29 Sampling Train

The standard glass filters are replaced with low background quartz filters. The impinger solutions are specific for different metals. Recovered samples are digested and appropriate fractions are analyzed by various means; inductively coupled argon plasma emission spectroscopy (ICPES), atomic absorption spectroscopy (AAS) or graphite furnace AAS, depending upon sensitivity required or the matrix effects on the specific analyte.

M29 Sampling TrainProduct Conversion Accessories

SB-4 Impinger Box/Insulated Coolant Reservoir Model 150, Holds 8 Impingers

NG-SET Set of 7 Glass Nozzles - Sizes 4,6,8,10,12,14&16, Includes Case and Three 5/8” Glass Filled PFA Ferrules

GF-3QR 3 inch Quartz Fiber Filters-100/box (MFS QR100 82mm)

GN-9AK Knock-Out Impinger, Short Stem, 500ml, Unground O-Ring Joints

GN-9A Modified Greenburg-Smith Impinger (Plain), Unground

GF-3Q 3 inch Quartz Fiber Filters-25/box (Pallflex 8.26cm)

PBT-5/8 PTFE Probe Brush, Extension, 10 Foot Flexible (Brush Not Included)

PBX-10T PTFE Probe Brush, 5/8” diameter, 4” length, 8-32 thread

NBT-1/2 Nozzle Brush, PTFE, 1/2 inch

Method 29 Recommended Accessories

Page 44: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

43

ISOKINETIC SOURCE SAMPLING EQUIPMENT

In the Ontario-Hydro Method (ASTM D6784-02) a sample is withdrawn from the flue gas stream isokinetically through probe/filter system, maintained at 120OC (250OF) or the flue gas temperature (whichever is greater), followed by a series of impingers in an ice bath. Particle-bound mercury is collected in the front half of the sampling train. Oxidized mercury is collected in impingers containing a chilled aqueous potassium chloride solution. Elemental mercury is collected in subsequent impingers (one impinger containing chilled aqueous acidic solution of hydrogen peroxide and three impingers containing chilled aqueous solutions of potassium permanganate). Samples are recovered, digested, and then analyzed for mercury using cold-vapor atomic absorption (CVAAS) or flourescence spectroscopy (CVAFS). The scope of the method applies to determination of elemental, oxidized, particle-bound and total mercury emissions from coal-fired stationary sources with concentrations ranging from approximately .05 to 100 ug/dscm. The sample train is similar to EPA Method 5.

ONTARIO-hYdRO – METhOd (ASTM d6784-02) MERCURY

Schematic of Ontario-hydro Method Sampling Train

Product Conversion Accessories

SB-4 Impinger Box / Insulated Coolant Reservoir Model 150, Holds 8 Impingers

NG-SET Set of 7 Glass Nozzles - Sizes 4,6,8,10,12,14&16, Includes Case and Three 5/8” Glass Filled PFA Ferrules

BS28WS #28 Ball Joint Clamp (Generic), Stainless Steel

NBT-1/2 Nozzle Brush, 1/2 inch diameter, PTFE Bristles

PBX-10T 10 foot Flexible PTFE Probe Brush Extension, Brush not Included

PBT-5/8 PTFE Probe Brush Tip (PTFE Barrel AND PTFE Bristles), 5/8 inch Bristle Diameter

GN-9A Greenburg-Smith Impinger (with orifice), Unground

GN-9AO Impinger Assembly, Stem with Orifice & Plate, 500ml, Unground O-Ring Joints, Greenburg-Smith

GN-11 U-Tube, #28 Unground Sockets

GF-3Q 3” Quartz Fiber Filters, 25/Box

Ontario-hydro Recommended Accessories

Ontario-hydro - Mercury Sampling Train

Page 45: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

44

ISOKINETIC SOURCE SAMPLING EQUIPMENT

Method 201A applies to the in-stack measurement of particulate matter (PM) emissions equal to or less than an aerodynamic diameter of nominally 10 microns (PM10) and or 2.5 microns from stationary sources. A gas sample is extracted at a constant flow rate through Apex instruments cyclone, which separates PM greater than PM10.. PM .less than PM10 is collected on the in-line filter. In order to maintain a cut size of 10 microns in the cyclone, the flow rate must be maintained at a constant, discrete value during the run. Apex cyclones meets the specifications of Method 201A and allows use of the equations in Method 201A to calculate the constant sample flow rate.

pm2-k

PARTICLE SIZING - PROPOSEd MOdIFICATION METhOd 201A

Packing List

Introducing PM1 CycloneApex Instruments now offers a cyclone designed for sampling very fine particulate matter in the 1.5 to 0.5 micron range. The cyclone is based on the cyclone “V” from the Multi-stage cyclone system designed and calibrated by Southern Research Institute under contract for the EPA. The design has been modified to accept the nozzles from the PM 2.5 cyclone, which has been expanded to a set of 12 different size nozzles. The sample flow rate must be maintained, in which the constant rate determines the actual “D50” cut-point. The cyclone is followed by a 47 mm filter assembly. Quartz or PTFE coated glass fiber filters should be used to minimize reactivity with the flue gas. The cyclone and nozzles are constructed from grade 316 stainless steel with Viton o-rings. Other materials are available upon request for corrosive or high temperature applications.

pm1-k

Product Size

PM2-N1 .125 Size 1

PM2-N2 .138 Size 2

PM2-N3 .156 Size 3

Apex Expanded Nozzle SetPM2-NS Nozzle Set Includes 1 Each

Product Size

PM2-N7 .216 Size 7

PM2-N8 .234 Size 8

PM2-N9 .253 Size 9

Product Size

PM2-N4 .172 Size 4

PM2-N5 .188 Size 5

PM2-N6 .200 Size 6

PM2-NS Nozzle Set Includes 1 Each

Product Size

PM2-N10 .274 Size 10

PM2-N11 .296 Size 11

PM2-N12 .320 Size 12

PM1 Cyclone Kit ComponentsThe PM1 Cyclone is used for in-stack measurement of very fine particulate matter. The 47 mm filter assembly outlet connector has a 5/8” outer diameter for easy installation Method 5 Probe Assemblies. The cyclone kit is enclosed in a sturdy plastic case.

Product description

PM1-K PM1 Cyclone Set Includes: Cyclone Body, 12 Nozzles, (PM2-NS), Filter (SFA-47), Manual and Case

PM1 PM1 Cyclone Body Only, Stainless Steel with Viton® O-Rings

PM2-NS Set of 12 Nozzles for PM1 and/or PM2.5 Cyclone, Stainless Steel

Packing List

Product description

PM2-K PM2.5 Cyclone Set Includes: Cyclone Body, 12 Nozzles, (PM2-NS), Filter (SFA-47), Manual and Case

PM2 PM2.5 Cyclone Body Only, Stainless Steel with Viton® O-Rings

PM2-NS Set of 12 Nozzles for PM2.5 Cyclone, Stainless Steel

PM2-NSA Add-On Set of 6 Nozzles (NS-7, 8, 9, 10, 11, 12) for upgrading PM2.5 Cyclone Existing Kits, Stainless Steel

O-024V Viton® O-Ring for PM2.5 Cyclone, (2 per cyclone).

O-024H High Temperature O-Ring for PM2.5 Cyclone, Stainless Steel

MPT-6-181 Pitot Tip, 3/8” Tube, Stainless Steel Replacement for Standard Method 5 Probe Assemblies

PM2.5 Cyclone Kit Components

PM2.5 Cyclone KitThe PM2.5 Cyclone is used for in-stack measurement of particulate matter equal to or less than 2.5 microns. The shank has a 5/8” outer diameter for easy adaptation to the Method 5 Probe Assemblies. The kit is enclosed in a sturdy plastic case with 12 nozzles.

Alloy 600 Components Available. Call for Pricing.

Page 46: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

45

ISOKINETIC SOURCE SAMPLING EQUIPMENT

PM10 Cyclone KitPM10 is used for Method 201A testing and is designed for in-stack measurement of particulate matter equal to or less than 10 microns. The shank has a 5/8” outer diameter for easy adaptation to Method 5 Probe Assemblies. The cyclone kit is enclosed in a sturdy plastic case with twelve nozzles (4” diameter port opening minimum). Call for High Temperature Alloy 600 PM10 Cyclones and Filter Holders.

pm10-k

Product description

PM10-K PM10-K Cyclone Kit, Includes: Cyclone, 12 Nozzles Set (PM10-NS), 47mm Filter Holder (SFA-47), Manual & Case

PM10 PM10 Cyclone Only, Stainless Steel with Viton® O-Rings

PM10-NS Set of 12 Nozzles for PM10 Cyclone (Now with 12 Nozzles)

O-032V Viton® O-Ring for PM10 Cyclone

O-032H High Temperature Stainless Steel O-Ring for PM10, Cyclone

MPT-6-320 Extended Pitot Tip for PM10, SFA-300, and SFA-2590

PM10 Cyclone Kit Components

PM10/2.5 Cyclone KitPM10/PM2.5 Set combines the in-stack measurement of particulate matter (PM) equal to or less than an aerodynamic diameter of nominally 10 (PM10) and 2.5 (PM2.5 ) microns from stationary sources. The sampling train and operation are identical to Method 201A except that the PM2.5 cyclone is inserted between the PM10 cyclone and the 47mm filter. The PM10 cyclone collects particulate matter greater than PM10 while the PM2.5 collects PM less than PM10 and greater than PM2.5. The in-line filter collects PM less than PM2.5 (6” diameter port opening minimum).

pm2.5-10k

Packing List

Product description

PM2.5-10K PM 2.5/10 Cyclone Kit Includes: PM10 Kit, with PM10/PM2.5 Nozzle, Cyclone Assembly, 47 mm Filter Assembly, Stainless Steel, Adapters, Pitot & Case

PM2/10-CK Connector Kit includes: GA-110 Strain Relief Adapter for PM2.5 and PM10 Cyclones, NSB-16 Button Hook Adapter for connecting the PM10/2.5 Cyclones, 10MSC5-S Connector, adapts NSB-16 to PM2.5 Cyclone, 5/8” TU to 5/16” bevel seat, Stainless Steel, and N-10UBNN SS Union, 5/8”, Bored out .660 with shoulder, Body only, No Nuts or Ferrules

PM2/10-CKI Connector Kit includes: INCONEL EQUIVALENT TO: GA-110 Strain Relief Adapter for PM2.5 and PM10 Cyclones, NSB-16 Button Hook Adapter for connecting the PM10/2.5 Cyclones, 10MSC5-S Connec-tor, adapts NSB-16 to PM2.5 Cyclone, 5/8” TU to 5/16” bevel seat, and N-10UBNN Union, 5/8”, Bored out .660 with shoulder, Body only, No Nuts or Ferrules

SFA-47 Filter Assembly, 47mm, 5/8TU, Stainless Steel, Method 17 In-Stack Filter Unit, 5/8 inch Tube Unions, uses 47mm diameter Filter Element

GA-110 Strain Relief Adapter for PM2.5 and PM10 Cyclones

NSB-16 Button Hook Adapter for Connecting the PM10/2.5 Cyclones

10MSC5-S PM10/2.5 Connector, Adapts NSB-16 to PM2.5 Cyclone,5/8” TU to 5/16” Bevel Seat, Stainless Steel

PM10/2.5 Cyclone Kit Components

PM10/2.5 Cyclone 12 Nozzle Set - 1 Each

Product Size

PM10-N6 .215 Size 6

PM10-N7 .233 Size 7

PM10-N9 .300 Size 9

Product Size

PM10-N3 .164 Size 3

PM10-N4 .180 Size 4

PM10-N5 .197 Size 5

Product Size

PM10-N10 .342 Size 10

PM10-N11 .390 Size 11

PM10-N12 .320 Size 12

Product Size

PM10-N0 .125 Size 0

PM10-N1 .136 Size 1

PM10-N2 .150 Size 2

Recommended Accessories for Sampling with Cyclone Sets.Power Box Adapter, Includes 1/2 inch Mounting Clamp and 4 Pin Amphenol to 3 Receptacles.ua-3J

Extended Pitot Tip for PM10/2.5 Sampling, Tube Diameter 3/8”, Length 421 mmmpt-6-421

47mm Glass Fiber Filters, 100/box (Whatman 934AH-4.7cm).gF-47

Sample Frame with Probe Clamp & Impinger Box SlidessB-8

Page 47: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

46

ISOKINETIC SOURCE SAMPLING EQUIPMENT

CI-700K Cascade Impactor Kit includes 7 stage impactor, a PRA-K pre-cutter, nozzles, interconnecting tube, glass fiber filters (45 mm, 47 mm and GFDN filters) and foil collection plate.

CI-700-K Stainless Steel Pre-Collector

Price Description

PRA-K Pre-Cutter Assembly Kit, Includes Body, Cap, Outlet Cap with Union, Nuts, Ferrulesand Set of 6 Nozzles

PRA-N4 1/8”

PRA-N6 3/16”

PRA-N8 1/4”

PRA-N10 5/16”

PRA-N12 3/8”

PRA-N16 1/2”

PRA-NS Set of 6 Pre-Collector Nozzles, Sizes 4-16

Cascade Impactor 7 Stage 47 mm filter outlet, Viton® O-Rings, Foil collection plates.

CI-700

Set of 7 Lightweight Stainless Steel Foil Collection Plate Inserts.

CI-FP

CASCADE IMPACTOR KIT

CI-700

PRA-K

CI-700-K

Data Reduction Software

Product Description

PM-2.5-10C Particle Sizing Software for PM2.5 and PM10 Cyclones

PARTICLE SIzING DATA REDUCTION SOfTwARE

functions• Calculates each stage’s aerodynamic cut point and DP50, needed to reduce particle size data. • Calculates and Stores ancillary data, such as dry gas composition and moisture content. • Reduces velocity traverse data. • Aids in selection of sample flow rates and ideal nozzle size. • Calculates flow rates and dwell times required for PM10 and PM2.5 sampling traverses. • Calculates fractional efficiencies of control devices from samples obtained at inlets and outlets.

wINCIDRS

Windows-based Cascade Impactor Data Reduction System (WINCIDRS) calculates particle size distribution of stack particulate matter (PM) taken with the Cascade Impactor, as well as particle-sizing cyclones. Developed by stack particle analysis experts, this software reduces the time and chances of error involved with reducing particle sizing data. (The PM10/2.5 Software Program (PM-2.5-10C) is extracted from WinCIDRS and simplified for use only with PM10 and PM2.5 cyclones. The calculations are similar to the WinCIDRS, scaled-down specifically for cyclone data reduction. The calculations are intensive enough to demand computer software.)

Page 48: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

47

ISOKINETIC SOURCE SAMPLING EQUIPMENT

This isokinetic method is used to measure Condensable Particulate Matter (CPM) from stationary source emissions after particulate matter has been removed by a heated filter, such as in Method 5, 17 or 201A. The CPM is collected in dry impingers. The impinger contents are purged with nitrogen (N2) immediately after sample collection to remove dissolved sulfur dioxide (SO2) gases from the impinger. The organic and aqueous fractions are dried and the residues are weighed. The total of the aqueous and organic fractions represents the CPM.

Method 202 (dry IMpInger Method)

Schematic of the M202 Sampling train

Method 202 Sampling train

Components ListgnFA-3U-18K3” filter assembly, ungrounded glass with 90 degree inlet and outlet, open style alum clamp. With rubberized silicone filter support.

gn-9AKSAKnock-out impinger assembly,ungrounded (for HorizMM5).Includes: GN-9AKSB (Bottle), GN-9AKS-I (Short Stem),GN-9AKS-IL (Purge Stem).

gF-3tM3” PTFE membrane filter - 50 per box(Palifex 90mm).

gn-VChM-M202M202 Spiral Condenser, #28 Ball and Socket. Water Jacket Hose Barbs, High Moisture sources above 15%.

MM5-pMMini submersible coolant pump, 110V.

MM5-p Submersible coolant pump, 110V.

SB-4SdImpinger box - insulated coolant reservoir model 150, holds 8 impingers.

gA-28S4Stainless steel adapter, 28mm socket to 1/4” FNPT, 3” long 400°F rating.

SFA-116IL Stainless steel filter housing in-line 1/4” FNPT, 3” long 400°F rating. Size: 1 Micron. Other sizes available.

SFA-1101t 316L mesh stainless steel elements are recommended for filtration of heavily contaminated gases, liquids, polymers, and steam. Temperature range of -65° F to 1000°F. Withstands 1000 PSIG differential.

FILter And pUrge AdApterFilter System for Purging Method 202.

Call for more details.

A

PurgeStem

GN-VCHM-M202

GN-8

See Page 45 for PM10-2.5 Configurations

See Page 40 for Available Pumps

See Page 28 for Full-Part Assembly Break-Down

For KnockoutGN-9AKSA

Method 202 (ContInUed on next pAge)

gn-9AKSB (Bottle)gn-9AKS-I ( Short Stem)gn-9AKS-IL (purge Stem)Can be Sold Separately

gn-9AKSB

gn-9AKS-IL

gn-9AKS-I

Page 49: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

48

ISoKInetIC SoUrCe SAMpLIng eQUIpMent

pp907-049

ntg-10Unn

Quantity product description1 SB-4SD Two Section Divided Impinger Box

1 GN-VCHM-M202 Vertical Condenser #28 Socket to M202 Spiral Condenser, #28 Socket both ends Water Jacket Hose Barbs, High Moisture Source above 15%.

1 GN-9AKSA Glass Knock-out Impinger Assembly, Unground, (for HorizMM5) included with Long / Short Stem

1 GNFA-3U-18K CPM 3” Filter Assembly including Flexable TC

1 GF-3TM TPFE Membrane Filters with Support, 1 Micron Pore Size, 50/Box

1 MM5-P MM5-P Submersible Coolant Pump, 110V

1 MM5-PM Mini Submersible Coolant Pump, 110V

1 SB-8 Sample Frame with Probe Clamp

1 SFA-116IL Stainless Steel Filter Assembly, 3” L In-Line

2 SFA-1101T Stainless Steel FIlter Element

1 GA-28S4 #28 Socket Bored Purge Adapter

1 GN-9AKA Knock-out impinger assembly, ungrounded (for HorizMM5). Includes: GN-9AKSB (Bottle), GN-9AKS-I (Short Stem), GN-9AKS-IL (Purge Stem).

Method 202 SAMpLIng ACCeSSorIeS

Method 202 pUrge ACCeSSorIeS

hexAVALent ChroMIUM pFA IMpInger trAInS & ACCeSSorIeS

SK-0061H SK-0061H-V

Method 0061 Hexavalent Chromium Emissions from Stationary Sources determines hexavalent chromium emissions from hazardous waste incinerators, municipal waste incinerators, municipal waste combustors and sewage sludge incinerators. Isokinetically collected with a train where the impinger reagent is recirculated continuously. Samples are analyzed with an ion chromatograph. Method 0061H Hexavalent Chromium High Temperature Source Sampling Kit is used as an alternative for temperatures above 150°C (300° F). Option “V” is added for 240 V.

Schematic of Method 0061h Sampling train

FILter And pUrge AdApterFilter System for Purging Method 202.

Call for more details.

hexavalent Chromium Method 0061 high or Low temperature Source Sampling Kit

• 4’ Stainless Steel Probe Assembly (Not Heated)• Glass Probe Liners (2)• Glass Nozzle Set• PTFE Impingers

• 30’ Split Umbilical • Impinger Box• Peristalic Pump• PTFE Membrane• Sample Frame

Page 50: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

49

ISOKINETIC SOURCE SAMPLING EQUIPMENT

Apex Instruments offers a wide range of filter media to meet any sampling requirements. Listed below are the standard media and sizes that Apex Instruments normally stock. Additional materials and sizes are available upon request.

FILTER MEdIA

QUARTZ FIBER FILTERSQuartz Fiber Filters are manufactured from pure quartz with-out a binder and are frequently used for sampling for metals analyses and acidic gases.

Model descriptionGF-2Q 2 inch Quartz Fiber Filters-25/box

GF-25Q 25mm Quartz Fiber Filters-100/box

GF-3Q 3 inch Quartz Fiber Filters-25/box (Pallflex 8.26cm)

GF-4Q 4 inch Quartz Fiber Filters-25/box (Pallflex 11 cm)

GF-45Q 45mm Quartz Fiber Filter-100/box

GF-47Q 47mm Quartz Fiber Filter-25/box

GF-54Q 54mm Quartz Fiber Filters-25/box (Pallflex 54mm)

GF-63Q 63.5mm Quartz Fiber Filters-25/box (Pallflex 63.5mm)

GF-3QR 3 inch Quartz Fiber Filters-100/box (MFS QR100 82mm)

GF-4QR 4 inch Quartz Fiber Filters-100/box (MFS QR100 110mm)

GF-47QR 47mm Quartz Fiber Filters-100/box (MFS QR100 47mm)

GF-90QR 90mm Quartz Fiber Filters-100/box (MFS QR100 90mm)

GLASS FIBER FILTERSGlass Fiber Filters are most commonly used filters for particulate sampling. All of the glass fiber filters are binder free and exhibit at least 99.9% efficiency for 0.3 micron dioctyl phthalate (DOP) smoke particles. Not recommended for metals analysis.

Grade E FIBER FILTERSIdeally suited for suspended solids analysis and high volume air monitoring applications. Softening point of glass fiber is 500°C, therefore upper limit temperature in use is 475°C. Low fiber shedding improves quality assurance of test results. high loading capacity. This media meets requirements for standard method 2540D and EPA Method 160.2 for establishing water quality in suspended solids content.

Model descriptionGF-2 2 inch Glass Fiber Filters-100/box

(934AH-5.5cm)

GF-2X6.5

2x6.5 inch Glass Fiber Filters-100/box (934AH)

GF-3 3 inch Glass Fiber Filters-100/box (934AH-8.26cm)

GF-4 4 inch Glass Fiber Filters-100/box (934-AH-11cm)

GF-45 45mm Glass Fiber Filters-100/box (934-AH-45mm)

GF-47 47mm Glass Fiber Filters-100/box(934AH-4.7cm)

GF-63 63.5mm Glass Fiber Filters-100/box (934-AH-63.5mm)

GF-90 90mm Glass Fiber Filters-100/Box (934AH-9.0cm)

GF-2E 2 inch Glass Fiber Filters-100/box Grade E

GF-3E 3 inch Glass Fiber Filters-100/box Grade E

GF-4E 4 inch Glass Fiber Filters-100/box Grade E

GF-25E 25mm Glass Fiber Filters-100/box Grade E

GF-47E 47mm Glass Fiber Filters-100/box Grade E

GLASS FIBER FILTERS

Page 51: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

50

ISOKINETIC SOURCE SAMPLING EQUIPMENT

ALUNDUM® THIMBLES (CERAMIC)Alundum® Thimbles are used for in-stack filtration for process engineering studies when a large sample is needed for analyses. These thimbles are made from fused alumina oxide and remain very constant in weight and can be re-used an infinite number of times. There are two different porosity thimbles that can be used in the SFA-300 thimble holder. The medium porosity retain particles 5 micron and larger and the coarse retain particles 20 micron and larger.

PTFE COATED GLASS FIBER FILTERS PTFE Coated Glass Fiber Filters are constructed from borosilicate microfibers and bonded with PTFE. The filters can be folded & handled without loss of fibers. Great for especially low loading rates. Specifically recommended for Method 26 & PM10 sampling.

Product descriptionGF-2T 2 inch PTFE Coated Glass

Fiber Filters-100/box

GF-3T 3 inch PTFE Coated Glass Fiber Filters-100/box (Pallflex 82.6mm)

GF-4T 4 inch PTFE Coated Glass Fiber Filters-100/box (Pallflex 11cm)

GF-25T 25mm PTFE Coated Glass Fiber Filters-100/box (Pallflex 2.5 cm)

GF-47T 47mm PTFE Coated Glass Fiber Filters-100/box (Pallflex 4.7cm)

GF-90T 90mm PTFE Coated Glass Fiber Filters-100/box (Pallflex 90mm)

PTFE FILTER MEMBRANESPTFE Filter Membranes are produced of pure PTFE resins. They withstand the most severely corrosive conditions at temperatures as high as 500°F (260°C) and down to the cryogenic range. The membrane is hydrophobic and maintains its strength wet or dry.

Model descriptionTF1121 PTFE Membrane, 47mm,

0.45 Micron (10/pack)

TF1131 PTFE Membrane, 47mm, 1-2 Micron (10/pack)

TF1141 PTFE Membrane, 47mm, 5-6 Micron (10/pack)

PTFE FILTER MEMBRANES

Product descriptionGF-90T 90mm PTFE Coated Glass Fiber Filters-100/box

(Pallflex 90mm)

GF-90T 90mm PTFE Coated Glass Fiber Filters-100/box (Pallflex 90mm)

GF-3TPG 3 inch PTFE Coated Glass Fiber Filters-50/box (MFS PG60) 82mm-Hydrophobic, Low absorption of acid gases such as SOX or NOX.

GF-4TPG 4" PTFE Coated Glass Fiber Filters-50/box (MFS PG60) 110mm-Hydrophobic, Low absorption of acid gases such as SOX or NOX.

GF-25TPG 25mm PTFE Coated Glass Fiber Filters-100/box (MFS PG60) 25mm-Hydrophobic, Low absorption of acid gases such as SOX or NOX.

GF-47TPG 47mm PTFE Coated Glass Fiber Filters-100/box (MFS PG60) 47mm-Hydrophobic, Low absorption of acid gases such as SOX or NOX.

Model descriptionGF-300C Alundum Thimble, medium porosity, 5+ micron retention, 34x100ml,

round bottom, fits SFA-300 use with additional O-ring, O-123V.

GF-300-C Alundum Thimble, COARSE porosity, 20 micron retention, 34x100ml, round bottom, fits SFA-300 use with additional O-ring, O-123V.

GF-300C

IN-STACK THIMBLES AND ACCESSORIES Apex Instruments stocks a variety of Fiber Thimbles for in-stack particulate sampling. The thimbles are seamless, high purity filters and available from a choice of two different types of fibers: Borosilicate glass and quartz. Borosilicate glass fiber thimbles are acid washed to reduce the trace metal content to an absolute minimum. Quartz fiber thimbles are strengthened with alumina and are prefired at 900°C for 2 hours during manufacturing to stabilize the weight prior to use. The gas collection efficiency of the thimbles is 99.9% (0.3 micron DOP). The 25 x 90mm thimbles are specifically manufactured for stack sampling and tapered for ease in loading. Cellulose thimbles are available upon request.

GF-2590Q

Model descriptionTF1165 PTFE Membrane, 25mm, 30-60 Micron (10/Pack)

GF-3TM 3 inch PTFE Membrane Filters-50/box (82.6mm) PTFE filter media provides durability for hostile acid aerosol monitoring. 1.0µm pore size membrane.

PTFE FILTER MEMBRANES

Model descriptionGF-190Q 19X90mm Quartz Fiber Filter

Thimble-25/box (For SFA-190)

GF-300Q 30x100mm Quartz Fiber Filter Thimble-25/box (For SFA-300) grade 88R

GF-2590Q 25x90mm Tapered Quartz Fiber Thimble-10/box (For SFA-2590) Grade 88R

QUARTZ FIBER THIMBLESModel descriptionGF-190 19x90mm Glass Fiber Filter

Thimble-25/box (For SFA-190)

GF-2590 25x90mm Tapered Glass Fiber Thimble -10/box (For SFA-2590) Grade 86R

GF-300 30x100mm Glass Fiber Filter Thimble-25/box (For SFA-300) Grade 86R

GLASS FIBER FILTER THIMBLES

Page 52: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

51

ISOKINETIC SOURCE SAMPLING EQUIPMENT

PTFE Probe Brush Extensions The flexible PTFE Probe Brush Extension attaches to the PBT-5/8 or PB-5/8. Made with 8/32 threads with a phenolic knob. Please specify length.

PTFE Probe BrushAll PTFE construction. The PBT-5/8” diameter with four spiral rows of black PTFE bristles. Over all length is 2”. The shaft is 1/4” diameter with 8-32 female threads. PTFE Barrel and PTFE Bristles.PBT-5/8

SAMPLE RECOVERY

PBT-5/8

NB-SET

B-3

B-4

PBX-S

Modular Probe Brush Set The PBX-S Modular Probe Brush Set contains two of the 5/8” stainless steel twisted wire brushes with nylon bristles and a total of 13’ in stainless steel extensions.PBX-S

Model description

PB- 5/8A Probe Brush/Stainless Steel, Nylon Bristles & Allen Set Screw (HD1088)

PBX-2 2’ Probe Brush Extension, Stainless Steel

PBX-3 3’ Probe Brush Extension, Stainless Steel

PBK-832 Probe Brush Knob

NOZZLE BRUSh SET The NB-SET Nozzle Brush Set includes one each of the three most popular sizes in a convenient carrying tube. (#3,#5,#8)NB-SET

B-1

Impinger Bottle Brush with Plastic Handle and Nylon Bristles.B-1

Impinger Bottle Brush

B-2

Flask Brush, Stainless Steel Handle and Nylon Bristles.B-2

Flask Brush

Filter Brush, 3/16” diameter, Stainless Steel Handle and Nylon Bristles, 5/16”.B-3

Filter Recovery Brush

Rubber Policeman with 18” Delrin® HandleB-4

Policeman

Model description

PBX-4T 4” PTFE ProbeBrush Extension

PBX-6T 6” PTFE Probe Brush Extension

PBX-8T 8” PTFE Probe Brush Extension

PBX-10T 10” PTFE Probe Brush Extension

PBX-12T 12” PTFE Probe Brush Extension

Brush Sold Separately

PTFE NOZZLE BRUShES Nozzle Brush NBT-1/2 is constructed of pure PTFE featuring a 1/8” diameter shaft with 1/2” long soft PTFE bristles. NBT-1/2

NBT-1/2

PBX- T

NOZZLE BRUShES Apex Instruments Nozzle Brushes feature stainless steel handle and nylon bristles. Super flexible for cleaning button hook nozzles with eye tip to reduce scarring of the nozzle.

Model description

NB-3 3/16” diameter, Nylon Bristles

NB-5 5/16” diameter, Nylon Bristles

NB-8 1/2” diameter, Nylon Bristles

NB-5

NB-8NB-3

20 ft.Teflon Sample Line Brush, 1/8” diameter rod with 1/2” long bristles B-5

Sample Line Brush

Page 53: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

52

ISOKINETIC SOURCE SAMPLING EQUIPMENT

250ML-CyL-PMP

Aluminum Weighing dishes (70 ml)100/pack.25433-062

Aluminum Weighing dishes 100 Pack (12.1 cm) 12175-001

Petri dish 100x15mm (3” Diameter),25/pack. 25373-1100

Petri dish 150x15mm (4” Diameter), 10/pack25373-187

Graduated Cylinder 250ml, Plastic250ML-CYL-PMP

Graduated Cylinder 250ml, Glass250ML-CYL

TW-1

Nylon TweezersTW-1

Polypropylene FunnelTop Diameter 108mm.

30255

Funnel Parafilm M, Laboratory Sealing Film, Roll is 2” x 250 ft.PARA-2X250

Synthetic Cotton Balls (For Impinger Outlet Filter), 300/bagMS-1

Cotton Balls

SAMPLE RECOVERY BOTTLES

POLYEThYLENE SAMPLE BOTTLES 125 mL vw/Wide Mouth, w/Cap.WB-1W250 mL w/Cap.WB-2p250 mL w/Wide Mouth.WB-2pW 16oz. / 500 mL w/Wide Mouth.WB-4p1000 mL w/Wide Mouth.WB-10p1000 mL w/Wide Mouth.WB-1000pW

Wide Mouth Bottles for Easy Filling and Pouring. The HDPE bottle with polypropylene closures are made of FDA compliant material. Recycling code molded into base of bottles. Simple to pour-wide mouth bottles. Chemically resistant. Leak proof, firm. Excellent for packaging chemicals, pharmaceuticals and adhesives.

WB-2P/with Cap250ml

WP-4B/with Cap500ml

FEP WASh BOTTLE500mL Wash Bottles, FEP.WB-500Fep

WB-500FEP

GSB-250

GLASS BOTTLES250mL Glass Sample Bottles with PFA-Lined Lid.Case of 12.gsB-250

SAMPLE RECOVERY ACCESSORIES

WB-5P

PLASTIC WASh BOTTLE500mL Plastic Wash BottlesWB-5p

Page 54: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

53

ISOKINETIC SOURCE SAMPLING EQUIPMENT

dESICCATOR ANd dESICCANTS Acrylic Desiccator Cabinets feature adjustable shelves with grooves for positioning, removeable lip tray, gasketed door, built-in hygrometer. Cabinets do not include Desiccant, order separately.

31000

www.belart.com

Features• Patented Sealed Construction is Airtight, Dust and Moisture Free.• Portable and Stackable with a Small Footprint.

PORTABLE dESI-VAC CONTAINER Desiccator with a vacuum pump is ideal for drying, preserving, storing, and even shipping samples. Vacuum pump built into the top removes air with manual strokes. Rubber O-ring sealed cover maintains vacuum. Achieves a vacuum of better than 200 inches of water (15 inches of mercury). A release button on top allows air into the container to remove the lid. Sample Humidity Sponges™ desiccant drying packets are included. O-ring-sealed cover maintains vacuum. Achieves a vacuum of better than 200 inches of water (15 inches of mercury A release button on top allows air into the container to remove the lid. Keep powder dry. Plastic container is ideal for storing chemicals, powders, tissues, plant sections, electronics, and weighing samples. Vacuum and desiccants keep mate-rial dry. Supplied with a vacuum indicating button that confirms interior vacuum and a dial hygrometer that displays 0 to 100% relative humidity with a resolution of 2%RH.Dimensions: HxWxD: 11” x 9” x 10”.

des-3164dES-3164

• Embedded UV Protection and Superior Chemical Resistance.• Built-in Hygrometer for Quick Check on RH Levels.• Rugged Construction with Sturdy Latches and Lock Provisions.

Model description dimensions Features

DES-10000 Desiccator Cabinet 8.4” x 13.4” x 16.3” Gasketed door, built in hygrometer, 0.75 cu.ft.

DES-21000 Desiccator Cabinet 12.4” x 13.4” x 16.3”, Gasketed door, 2 shelves, built in hygrometer 1.17 cu.ft.

DES-21115 Auto-Desiccator Cabinet

12.4” x 13.4” x 16.3” Gasketed door, 2 shelves, built in hygrometer 1.17 cu.ft. 110V

DES-21115V Auto-Desiccator Cabinet

12.4” x 13.4” x 16.3”, Gasketed door, 2 shelves, built in hygrometer 220V fan, 1.17 cu.ft.

DES-31000 Desiccator Cabinet 16.4” x 13.4” x 16.3”, Gasketed door, 3 shelves, built in hygrometer stackable

DES-31115 Auto-Desiccator Cabinet

16.4” x 13.4” x 16.3”, Gasketed door, 3 shelves, built in hygrometer stackable, 110V

DES-31115V Auto-Desiccator Cabinet

16.4” x 13.4” x 16.3”, Gasketed door, 3 shelves, built in hygrometer 220V fan

DES-40000 Desiccator Cabinet 13.4” x 20.4” x 16.3”,

Gasketed door, 2 shelves, horizontal Profile

DES-41115 Auto-Desiccator Cabinet

20.4” x 13.4” x 16.3” Gasketed door, 3 shelves, built in hygrometer

DES-41220 Auto-Desiccator Cabinet

20.4” x 13.4” x 16.3”, Gasketed door, 3 shelves, built in hygrometer, 220V fan

Page 55: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

54

ISOKINETIC SOURCE SAMPLING EQUIPMENT

Adsorption Housing, 1/4” FNPT Fittings. Without Sorbent.

SILICA GELBlue Indicating, 12/case, 250 ml per bottle.

sg-kitSG-KIT

Apex Instruments Silica Gel is primarily used for drying sample gas prior to measurement and can absorb moisture 40% of its weight. The silica gel can be regenerated by drying in an oven and used over and over again.

SILICA GEL

SILICA GEL3-5mm Bead, Indicating, 2.3Kg.

sg-3/5B

24005 14005

Part Number description

14005 DRIERITE®, Nonindicating 10-20 Mesh, 5 Lbs. (2.3 kg)

23005 DRIERITE®, Indicating 8 Mesh, 5 Lbs. (2.3 kg)

24005 DRIERITE®, Indicating 10-20 Mesh, 5 Lbs. (2.3 kg)

26840 DRIERITE®, Cartridge, 50g H2O Capacity

26809 Mounting Clip for Use with Gas Drying Units

SG-3/5B

The activated alumina is primarily used for air drying at low temperature applications, 5.5 lb. container.

80% Activated Alumina (White). 1/8” Diameter Beads.

20% Silica Gel (Blue) 3-5 mm Beads.

Aluma-sorb

ACTIVATEd ALUMINA WITh SILICA GEL

Aluma-sorb

SILICA GEL3-5 mm Bead, Bulk55 LBS, CONTAINER.

sg-3/5B-55

Ah-610R

dRIERITE® dESICCANTSApex Instruments carries both non indicating and indicating DRIERITE®. (anhydrous calcium sulfate) Economical to use, it can be regenerated repeatedly. The indicating DRIERITE® is impregnated with cobalt chloride: blue when dry and changes to pink upon absorption of moisture.

SG-3/5B-55

ah-610r

Page 56: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

55

ISOKINETIC SOURCE SAMPLING EQUIPMENT

BALANCES

MOdEL dESCRIPTION

BAL-EJ1500 1500g x 0.1 g.

BAL-EJ3000 3100g x 0.1 g.

BAL-EJ6100 6100g x 0.1 g.

BAL-EJ02 USB Interface with Cable

BAL-EJ12 Carrying Case

EJ-SERIES• Easy to read LCD Display with Backlight

• Percentage and Counting

• USB or RS-232 Interface Optional

• Battery Operated (4 x AA not included)

• AC Adapter Included

• Pan Size: 5” x 5.5”

• Check-Weighing Capacity

• 5 Year Warranty

PORTABLE BALANCES

MOdEL dESCRIPTION WEIGhT

BAL-W1000ASTM Weight for Electronic Balance. 1 kg. ASTM GRADE 7

BAL-W2000ASTM Weight for Electronic Balance. 2 kg. ASTM SHAPE

BAL-W5000ASTM Weight for Electronic Balance. 5 kg. Class F, meet Tolerances of NIST

CALIBRATION WEIGhTS

COMES wiTh CERTiFiCATE OF CONFORMANCE

Page 57: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

56

ISOKINETIC SOURCE SAMPLING EQUIPMENT

BALANCES

MOdEL dESCRIPTION PAN SIZE

BAL-HR60-C 60g x 0.1mg with RS-232C. 3.3”

BAL-HR120-C 120g x 0.1mg with RS-232C. 3.3”

BAL-HR200-C 210g x 0.1mg with RS-232C. 3.3”

BAL-HR202i 220g/51g x 0.1mg/0.01mg Semi-Micro with R-232C. 3.6”

hR-SERIES• Percentage and Counting Modes.

• Digital Preset Tare.

• One Touch Printing.

• Last Digital Suppression.

• Standard Underhook.

• Optional Rechargeable Battery Pack.

• GLP/LIMS/ISO Compliant.

• RS-232C Standard.

• 5 Year Warranty.

ANALYTICAL BALANCES

Analytical Balances - Calibration Weight Set

MOdEL

BAL-W1-100

dESCRIPTIONWeight Set - 1mg-100gStainless Steel Calibration Weight Set for Lab Use. Set of 9 Weights Plus Fractional Weights in Wooden Storage Box.

Note: Please check with State Department of Weights and Measurements for calibrations.

Page 58: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

57

ISOKINETIC SOURCE SAMPLING EQUIPMENT

METER CALIBRATION

CALIBRATION SERVICESApex performs both calibrations using a wet test meter and bell-prover primary standard. Calibration services are available from Apex Instruments on a fee per console basis. Extra charge for low flow. All console and dry gas meter calibrations are conducted in accordance with U.S. EPA standards. Apex Instruments calibrates source sampler consoles, reference dry gas meters, orifices and pitots.

Calibration being performed with Wet Test Meter

dRY GAS SECONdARY REFERENCE METER (ENGLISh)Dry Gas Meter Secondary Reference Meter (Standard) with 15 pt cal, valve, 5’ hose, 1/2” Quick Connect. Used for calibrating Method 5 Source Sampler Consoles.

dgm-110sr

SECONdARY REFERENCE METER (METRIC)Dry Gas Meters Secondary Reference Meter (Metric AP25) with 15 pt cal, valve, 5’ hose, 1/2” Quick Connect.Used for calibrating Method 5 Source Sampler Consoles.

dgm-ap25sr

METER CALIBRATION EQUIPMENT

Model description

DGR-2VER Verification of DGM for Secondary Reference, 2 Point Verification of Previous Calibration

DGMC-5A Pre-Test 5 Point Calibration for Compatible Meter Consoles

DGMC-3A Post Test 3 Point Calibration for Meter Consoles

CAL-ORF Orifice Calibration, 3 Point

dRY GAS METER CALIBRATION SERVICES

dGM-110SR dGM-AP25SR

Page 59: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

58

ISOKINETIC SOURCE SAMPLING EQUIPMENT

U.S. EPA allows critical orifices to be used as calibration standards. The orifice calibration set contains five of our critical orifices with 1/2” quick connects and software. Recalibration recommended annually. Calibration Orifice Set, 5 Calibrated Critical Orifices and Spreadsheet Diskette for Method 5.

CALIBRATION ORIFICE SET

m5Co-set....$510.00

Available on CD

Model A description: Shinagawa Precision Wet Test Meter Weight height Width depth

W-NK-0.5A Max Flow 5 LPM, 0.5 Liter per Revolution 4.5kg 420 290 190

W-NK-1A Max Flow 10 LPM, 1 Liter per Revolution. 6.0kg 450 315 210

W-NK-2A Max Flow 20 LPM, 2 Liter per Revolution 9.0kg 390 350 255

W-NK-2.5A Precision Meter, 2.5 Liter Capacity, 5 to 1500 L/HR 9.0kg 390 350 255

W-NK-5A Precision Meter, 5 Liter Capacity, 5 to 3000 L/HR 25kg 575 455 295

W-NK-10A Precision Meter, 10 Liter Capacity, 20 to 6000 L/HR 35kg 656 535 380

The Best Standard for Calibration of dry Gas Meters.

Different Models Available.

The Model W-NK Wet Gas Meter is a net-volume type integrating flowmeter that employs a drum as the metering element. As the drum is sealed with water or other fluid, the Model W-NK provides the measurement of any gas irrespective of the gas specific gravity and viscosity. Further, since this gas meter permits the measurement of very small flows, exhibits high reproducibility, and offers various other excellent features, it properly serves as a standard as well as a testing instrument.

PRECISION WET TEST METERSCALIBRATION EQUIPMENT ANd SERVICES

Model B description: Shinagawa Precision Wet Test Meter Weight height Width depth

W-NK-0.5B Max Flow 5 LPM, 0.5 Liter per Revolution, Corrosion Resistant 4.5kg 420 290 190

W-NK-1B Max Flow 10 LPM, 1 Liter per Revolution, Corrosion Resistant 6.0kg 450 315 210

W-NK-2B Max Flow 20 LPM, 2 Liter per Revolution, Corrosion Resistant 9.0kg 390 350 255

W-NK-2.5B Precision Meter, 2.5 Liter Capacity, 5 to 3000 L/HR, Corrosion Resistant

9.0kg 390 350 255

W-NK-5B Precision Meter, 5 Liter Capacity, 5 to 3000 L/HR, Corrosion Resistant

25kg 575 455 295

W-NK-10B Precision Meter, 10 Liter Capacity, 20 to 6000 L/HR, Corrosion Resistant

35kg 656 535 380

W-NK

Model description

M5CO-40 Calibration Critical Orifice, Size 40, Flow Rate. ~.31cfm (~8.8 lpm) with 1/2” Male QC

M5CO-48 Calibration Critical Orifice, Size 48, Flow Rate. ~.46cfm (~13.0 lpm) with 1/2” QC

M5CO-55 Calibration Critical Orifice, Size 55, Flow Rate. ~.61cfm (~17.3 lpm) with 1/2” QC.

M5CO-63 Calibration Critical Orifice, Size 63, Flow Rate. ~.79cfm (~22.4 lpm) with 1/2” QC.

M5CO-73 Calibration Critical Orifice, Size 73, Flow Rate. ~1.1cfm (~31.14 lpm) with 1/2” QC.

Orifice Set Contains the following:

Page 60: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

59

ISOKINETIC SOURCE SAMPLING EQUIPMENT

dIAL CALIPERS

Geometric of Type-S Pitot Tube to Method 2.

pt-Cal-gWind Tunnel of Type-S Pitot Tube to Method 2.

pt-Cal-W

PITOT CALIBRATION SERVICES

ThERMOCOUPLE SIMULATOR / CALIBRATOR This Thermocouple Simulator/Calibrator is convenient for checking the accuracy of most Controllers and Temperature Displays. Whe Cold Junction Compensated, is calibrated without External Compensators or Icebaths the Simulator Source is designed for Type-K Thermocou-ples and has 22 precise test points.

m5C-520

dial Calipers are used for measuring nozzle diameter and inspection of pitots. Dial Caliper, 0-6”/ 150mm Direct inch/Metric Conversion.

m5C-3d

NOZZLE CALIBRATION

CALIBRATION EQUIPMENT ANd SERVICES

M5C-520

BULL’S EYE LEVELBull’s Eye Level is 1/2” diameter and used for pitot calibrations. Comes with thumb screws for clamping to pitot.

m5C-2

M5C-2

Pendulum Style Inclinometer for the Calibration of Type-S Pitots.

inC-a300

A300 LEVEL INdICATOR

INC-A300

PITOT AUdIT EQUIPMENT & MANOMETERS

Meriam Handheld, LCD DISPDigital Manometer, Hand held, 0-28 inch H2O Selectable Range, English/Metric, with certificate of NIST traceability.

dhm-m100

hANdhELd MANOMETER

dhM-M100

hANdhELd MANOMETER LCD DISP., Digital Manometer, Method 2, Hand held, 0-10 inch H2O Selectable Range, English/Metric.

dhm-28-10

dhM-28-10

MANOMETER SOFTWARE Software and cable for Digital Manometer, HM28 series.

dhm-28-1

MANOMETER dIGITAL dISPLAYDP-CALC Micromanometer makes differential pressure measurements, static, total, and velocity pressures as well as pressure drops across filters, coils, fans, and diffusers. Differential and static pressure from -15 to +15 in. H2O (-3735 to +3735 Pa) lightweight and durable design with an easy-to-read display, certificate of NIST traceability.

dhm-5825

Page 61: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

60

ISOKINETIC SOURCE SAMPLING EQUIPMENT

MONORAILS

MONORAIL hARdWARE

(Threaded pipe flanges are available in 3”, 4” or 6”, stainless steel or aluminum.) Note: The chain must be attached to the stack so that the chain angle to the monorail is no less than 30° (45° is recommended).

PF- CSPipe Flange

PART # Monorail with Cable and Chain LF

P1001-10 MONORAIL, 10FT, STEEL Heavy Duty, Double Channel, W/CHAIN, L-Bracket & Hardware.

10

P1001-12 MONORAIL, 12FT, STEEL Heavy Duty, Double Channel, W/CHAIN, L-Bracket & Hardware.

12

P1001-14 MONORAIL, 14FT, STEEL Heavy Duty, Double Channel, w/ Adjustment Chain, L-Bracket & Hardware.

14

P1001-16 MONORAIL, 16FT, STEEL Heavy Duty, Double Channel, w/Cable, Adjustable Strap, L-Bracket & Hardware.

16

P1001-17 MONORAIL, 17FT, STEEL Heavy Duty, Double Channel, w/Cable, Adjustable Strap, L-Bracket & Hardware.

17

P1001-18 MONORAIL, 18FT, STEEL W/CHAIN Heavy Duty, DoubleChannel, w/Cable, Adjustable Strap, L-Bracket & Hardware.

18

PART # Flange

PF-3CS Flange, 3” 150 lb. FF, 2.67 Bored, Stainless Steel, with Threaded Coupling.

PF-4CS Flange, 4” 150 lb. FF, 2.67 Threaded, Stainless Steel, with Threaded Coupling.

PF-6CLS Flange, 6” 150 lb. FF, 2.67 Bored, Stainless Steel with Cam-lock Connector.

See Accessories Section for Different Configurations.

PART # Trolley and Monorail Support Bracket

P2751 MONORAIL, TROLLEy Swivel Frame Trolley with Eyebolt, 1 Foot Chain and Snap-hook.

P501 MONOMOUNT, MONORAIL SUPPORT Support Bracket; Fits 3”, 4”, 6” & 8”, Standard Pipe Flanges, Includes P1354 Hinge, (4) P3010 Nuts and P371 Bolts.

Link to Flanges

LF 6 7 8 9 10 12

Part # P1000-6 P1000-7 P1000-8 P1000-9 P1000-10 P1000-12

Probe Size

For use with probes over 6’

For use with probes over 7’

For use with probes over 8’

For use with probes over 9’

For use with probes over 10’

For use with probes over 12’

Monorail with ChainHeavy Duty Steel Monorail with Chain, L-Bracket and Hardware (for use with probes).

Page 62: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

61

ISOKINETIC SOURCE SAMPLING EQUIPMENT

XC-522 and XC-572 Components ListPart Number Description QC-MAN-M2 QC-Manometer, M-1/4HB, Delrin XC-10U Black RotoRack Shallow Case M-RA911 Switch, Curvette, EC Comp., I-O AM-MCP Replacement Meter Console Wired Amphenol Sub-Assembly M-422B Bracket, Manometer, Adjust, Stainless Steel M-422DS Manometer Displacer Knob L-441160 Latch, Panel, Screw, Large, Sou 3439T12 Webbing, 2”, Black Nylon M-CBR5A-M Magnetic Type Circuit Breaker Rocker Switch, 5 Amp., 120V M-CBR3A-M Magnetic Type Circuit Breaker Rocker Switch, 3 Amp., 240V

Part Number Description TC-765KF Display, TC, PNI, LED, 120/220V M-SD31 Controller, Temp, Red LED, Watlow MC-T Timer, MC, Veeder-Root M-SCKT15A Conn, Pwr, IEC Inlet 15A/250V M-49BK Recept, EL, Snap-In, Term M-31302A Switch, TC. 7 Channel TC-PJK TC Jack, Type K, PNL, Snap-In QC-BHF8-SS QC, Blkhd, 1/2IN-1/2TU, F, SS QC-BHF4-SS QC, Blkhd, 1/4IN-1/4TU, F, SS QC-BHF6-SS QC, Blkhd, 3/8IN-3/8TU, F, SS QC-BHM6-SS QC, Blkhd, 3/8IN-3/8TU, M, SS B2VH-6S Valve, Ball, 3/8TU, SS, PNL, Nut NV3HA-6S Valve, Needle, Angle, 3/8T-3/8T, S DGM-110 Meter, Dry Gas, 110 Rockwell G301U Gage, Vac, 0-30HG, 1.5IN, PNL M-42210 Manometer, Dual, PNL, 0-10” H2 QC-MAN-F3 QC-Manometer, F-1/8MNPT, S

1234567891011121314151617

18192021

22

23242526

27

xC-522 SoUrCE SAMPLING CoNSoLE (ENGLISh) xC-572 SoUrCE SAMPLING CoNSoLE (METrIC)

TC-765KF

Temperature Display

Manometer Quick Connects

Fine Control Valve

Manometer Zero Adjust Knobs

Manometer Level Adjust

Standard Stainless Steel Pitot Quick

Connects

Standard Stainless Steel Sample Quick Connect

Standard StainlessSteel Female Pump Connection (Pressure)

UmbilicalCable Power Connection

Color Coded Thermocouple Jacks

7-ChannelTemperature

Selector Switch

Vacuum Gauge

Elapsed Timer

Rugged Custom Molded X-Case

Digital Filter and Probe Temperature

Controllers

Stainless Steel MaleNon-Reversible Pump

Quick Connect(Vaccum)

Strap

9

10

11

1

7

XC-10U19

13

4

21

ElectricReceptacle

Power Connect Inlet

25 3439T12

Heavy Duty Panel Latches

24 L-441160

XC-522 Dry English Gas Meter14 dGM-110

CoarseControl Valve

12 B2Vh-6S

Dual Column

Manometer

16 M-42210

1718 QC-MAN-M2

QC-MAN-F32 M-Sd31

MC-T

G301U

3

15

M-31302A 6

TC-PJK

QC-BhM6-SS

QC-BhF6-SS

5M-49BK

QC-BhF8-SS8

QC-BhF4-SSAM-MCP NV3hA-6S

M-422B22

M-422dS23

Rocker Switches

M-RA91120

M-SCKT15A

XC-522

28 dGM-AP25

XC-572 Dry Metric Gas Meter

XC-572 (Metric) DGM-AP25 Meter, Dry Gas, AP25 W/Union 28

Magnetic Type Circuit Breaker Rocker Switch

M-CBR3A-M27

M-CBR5A-M26

Call for information on 110V / 240V Models.

Page 63: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

62

ISOKINETIC SOURCE SAMPLING EQUIPMENT

ConVersion FaCtorsConversion Factors

To Convert From to multiply ByareaSquare Feet (ft2) Square Centimeters (cm2) 929.0304

Square Feet (ft2) Square Meter (m2) 0.09290304

Square Feet (ft2) Square Inches (in2) 144

Square Inches (in2) Square Centimeters (cm2) 6.4516

LengthFeet (ft....) Centimeters (cm) 30.48

Feet (ft....) Meters (m) 0.3048

Feet (ft....) Inches (in) 12

Inches (in) Millimeters (mm) 25.4

Inches (in) Centimeters (cm) 2.54

Mass/ForcePounds (lb) Grains (gr) 7000

Pounds (lb) Grams (g) 453.59237

Grains (gr) Grams (g) 0.06479891

Kilograms (kg) Pounds (lb) 2.2046226

Kilogram-force (kgf) Newton (N) 9.80665

Pound-Force9 (lbf) Newton (N) 4.44822

temperatureDegrees Celsius (°C) Kelvin (K) K = °C + 273.15

Degrees Celsius (°C) Degrees Fahrenheit (°F) °F = 9/5 (°C + 32)

Degrees Fahrenheit (°F) Degrees Rankine (°R) °R = °F + 459.67 = 1.8k

Degrees Fahrenheit (°F) Degrees Celsius (°C) °C = 5/9 (°F -32)

Power, Energy, heatBritish Thermal Unit per Min. (Btu/min.) Steam, Pounds per Hour (lb/hr Steam) 1 X 103

Horsepower (hp) Watts (W) 745.7

Horsepower, boiler (hp) British Thermal Unit Per Hour (Btu/hr) 33445.7

Horsepower, boiler (hp) Kilowatts (kW) 9.8095

Kilowatts, Hours (kWhr) British Thermal Unit Per Hour (Btu/hr) 3414.43

British Thermal Unit, mean (Btu) Kilogram-Calories (kcal) 0.252

British Thermal Unit, mean (Btu) Watts per Second, Joule (J) 1055.06

PressureInches of Mercury (in Hg) Millimeters of Mercury (mm Hg) 25.4

Inches of Mercury (in Hg) Inches of Water (in H20) 13.6

Inches of Mercury (in Hg) Atmospheres (atm) 0.0334211

Inches of Mercury (in Hg) Kilopascals (kPa) 3.386388

Atmospheres (atm) Bars (bar) 1.01325

Atmospheres (atm) Pounds per Square Inch (psi) 14.695949

Pascals (Pa) Newton per Square Meter (N/m2) 1.0

VolumeCubic Meters (m3) Cubic Feet (ft3) 35.314667

Cubic Feet (ft3) Liters (l) 28.136847

Liters (l) Cubic Centimeters (ccm) 1000

Page 64: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

63

ISOKINETIC SOURCE SAMPLING EQUIPMENT

equations

Page 65: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

64

ISOKINETIC SOURCE SAMPLING EQUIPMENT

Avogadro’s Number 6.02 x 1023 atoms/g atomGas Constants 82.05 atm cm3/(g-mole * K) 1.987 cal/(g-mole * K) 10.731 ft.... lb in2/(lb-mole * oR) 0.732 ft3 atm/(lb-mole * oR)1 g-mole of Ideal Gas 24.05 Liters at US EPA Standard Conditions

Constants

Standard Temperature (Tstd) 20oC (68oF)Standard Pressure (Pstd) 760mm Hg (29.92in Hg)

us epa standard Conditions

gas ConCentration unitsParts-per-million by volume (ppmv) to milligrams per dry standard cubic meter (mg/dscm)

Correct to x% O2

−−

×=)(2

2%@ %9.20

%9.202

dryactualsOxs O

OxCC

Gas Concentration UnitTo Convert From To Multiply ByParts-per-million(ppm) SO2 Nanogram/Std Cubic Meter (ng/scm) SO2 2.66 x 106

Parts-per-million(ppm) SO2 Pounds/Std Cubic Foot (lb/scf) SO2 1.660 x 10-7

Parts-per-million(ppm) NOx Nanogram/Std Cubic Meter (ng/scm) NOx 1.912 x 106

Parts-per-million(ppm) NOx Pounds/Std Cubic Foot (lb/scf) NOx 1.194 x 10-7

Page 66: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

65

ISOKINETIC SOURCE SAMPLING EQUIPMENT

An Sampling Nozzle Cross-Sectional Area, mm2 (in2)As Stack Cross-Sectional Area, m2 (ft2)Bws Percent Moisture in Stack Gas, % H2OCp Pitot Tube Calibration CoefficientCp(std) Standard Pitot Tube Calibration Coefficientcs Particulate Concentration in Stack Gas, g/dscm gr/dscm (lb/dscf gr/dscf)De Equivalent Diameter, m (ft....)Dn Sampling Nozzle Diameter, mm (in)∆p Stack Gas Velocity Pressure, mm H2O (in H2O)(∆p1/2) avg Average of the Squareroots of Velocity Pressure, (mm H2O)1/2 (in H2O)1/2

%EA Percent Excess Air, %Fd F factor for dry effluent, used with percent O2, dry basisFo Fuel Factor∆H@ Pressure Drop across Orifice Meter for 21.2 lpm (0.75cfm) at Std Conditions, mm H20 (in H2O)∆H Pressure Drop across Orifice Meter, mm H20 (in H2O)%I Isokinetic Sampling Rate, %K Isokinetic Rate ConstantK’ Critical Orifice Calibration FactorKp Pitot Tube ConstantL Length of Duct Cross-Section at Sampling Site, m (ft....)m Mass, g (lb)Md Stack Gas Dry Molecular Weight, g/g-mole (lb/lb-mole)Ms Stack Gas Wet Molecular Weight, g/g-mole (lb/lb-mole)pmr Pollutant Mass Emission Rate, kg/hr (lb/hr)Pb Barometric Pressure, mm Hg (in Hg)Ps Absolute Stack Pressure, mm Hg (in Hg)Pstd Standard Pressure, 760 mm Hg (29.92 in Hg)Qaw Actual Wet Volumetric Flowrate, acmm (acfm)Qsd Dry Standard Volumetric Flowrate, dscmm (dscfm)ρw Density of Water, 0.9982 g/mlθ Time (minutes)Ts Stack Temperature, oC (oF)Tstd Standard Temperature, 293K (528oR)Tamb Ambient Temperature, oC (oF)Vcr Critical Orifice Volume, m3 (ft3)Vm Dry Gas Meter Volume, m3 (ft3)Vlc Volume or Mass Liquid Collected in Impingers, ml or gW Width of Duct Cross-Section at Sampling Site, m (ft....)y Dry Gas Meter Calibration Factor

nomenClature

Page 67: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

66

ISOKINETIC SOURCE SAMPLING EQUIPMENT

MERCURY SAMPLING EQUIPMENT APPENdIX K SORBENT TRAP MONITORING

METhOd 30B SORBENT TRAP RELATIVE ACCURACY TESTING AUdIT (RATA)

ISOKINETIC SAMPLING EQUIPMENT METhOd 1 dETERMINATION OF SAMPLING LOCATION ANd TRAVERSE POINTS

METhOd 2 dETERMINATION OF STACK GAS VELOCITY ANd VOLUMETRIC FLOW RATE

METhOd 3 dETERMINATION OF EXCESS AIR ANd dRY MOLECULAR WEIGhT

METhOd 4 dETERMINATION OF MOISTURE IN STACK GASES

METhOd 5 dETERMINATION OF PARTICULATE EMISSIONS FROM STATIONARY SOURCES

METhOd 5B NONSULFURIC ACId PM

METhOd 8 SULFURIC ACId MIST & SO2

METhOd 12 INORGANIC LEAd (SZL)

METhOd 13A TOTAL FLUORIdES (SIE)

METhOd 13B TOTAL FLUORIdES

METhOd 17 PARTICULATE BY IN-STACK FILTRATION

METhOd 23 dIOXINS & FURANS

METhOd 26A hYdROGEN hALIdES & hALOGENS

METhOd 29 MULTIPLE METALS

METhOd 201A PM10 EMISSIONS

METhOd 202 CONdENSABLE PARTICULATE MATTER

METhOd 202 CONdENSABLE PARTICULATE MATTER FIGURES

METhOd 206 AMMONIA

METhOd 306 hEXAVALENT ChROMIUM FROM ELECTROPLATING ANd ANOdIZING OPERATIONS

METhOd 316 FORMALdEhYdE FROM MINERAL WOOL ANd WOOL FIBERGLASS NdUSTRIES

METhOd 0010 SEMIVOLATILE ORGANIC COMPOUNdS

METhOd 0011 FORMALdEhYdE, OThER ALdEhYdES ANd KETONES

METhOd 0061 hEXAVALENT ChROMIUM

FLOW, PRESSURE & TEMPERATURE METhOd 2 dETERMINATION OF STACK GAS VELOCITY ANd VOLUMETRICFLOW RATE (TYPE S-PITOT TUBE)

GAS SAMPLING EQUIPMENT METhOd 4A STACK GAS MOISTURE (APPROX. METhOd)

METhOd 6 SULFURIC ACId MIST & SO2

METhOd 6A SULFURIC dIOXIdE, MOISTURE ANd CARBON dIOXIdE

epa reFerenCe methods

METhOd 6B SULFUR dIOXIdE ANd CARBON dIOXIdE

METhOd 11 hYdROGEN SULFIdE IN PETROLEUM REFINERY FUEL GAS STREAMS

METhOd 15A TOTAL REdUCEd SULFUR FROM PETROLEUM REFINERY SULFUR PLANTS

METhOd 16A TOTAL REdUCEd SULFUR

METhOd 18 INTEGRATEd BAG SAMPLING FOR ORGANIC COMPOUNdS

METhOd 26 hYdROGEN hALIdES & hALOGENS

METhOd 106 INTEGRATEd BAG SAMPLING FOR VINYL ChLORIdE

METhOd 308 METhANOL

METhOd 0030 VOLATILE ORGANIC COMPOUNdS (VOST)

METhOd 0031 VOLATILE ORGANIC COMPOUNdS (SMVOC OR SUPERVOST)

METhOd 0040 PRINCIPLE ORGANIC hAZARdOUS CONSTITUENTS (POhCS) USING TEdLAR® BAGS

METhOd 0051 hYdROGEN ChLORINE ANd ChLORINE

GAS ANALYSIS EQUIPMENTMEThOd 3 GAS ANALYSIS FOR ThE dETERMINATION OF dRY MOLECULAR WEIGhT

METhOd 3B GAS ANALYSIS FOR ThE dETERMINATION OF EMISSION RATE CORRECTION FACTOR OR EXCESS AIR

METhOd 7 dETERMINATION OF NITROGEN OXIdE EMISSIONS FROM STATIONARY SOURCES

IRM EQUIPMENTMEThOd 3A dETERMINATION OF OXYGEN ANd CARBON dIOXIdE CONCENTRATIONS IN EMISSIONS FROM STATIONARY SOURCES

METhOd 6C dETERMINATION OF SULFUR dIOXIdE EMISSIONS FROM STATIONARY SOURCES

METhOd 6C dETERMINATION OF SULFUR dIOXIdE EMISSIONS FROM STATIONARY SOURCES FIGURES

METhOd 7E dETERMINATION OF NITROGEN OXIdES EMISSIONS FROM STATIONARY SOURCES METhOd 10 dETERMINATION OF CARBON MONOXIdE EMISSIONS FROM STATIONARY SOURCES

METhOd 25A dETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Page 68: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

67

ISOKINETIC SOURCE SAMPLING EQUIPMENT

Meter Calibration .............................................57Meter Calibration Equipment ...........................57Method 4 .........................................................33Method 4, Accessories ....................................33Method 5, Basic ..............................................34Method 5, Deluxe-Plus ....................................34Method 5, Compact .........................................35Method 5, Heated Filter Assembly ...................35Method 5, 5G ..................................................36Method 5, 5I ....................................................36Method 5, Alternate 5I .....................................36Method 8 .........................................................37Method 8, Accessories ....................................37Method 8, Alternate CTM-13 ...........................37Method 17, Flexible & Rigid.............................38Method 17, In-Stack Filter Assemblies ............39Method 17, Integrated In-Stack Filter Assemblies .............................................39Method 17, Glass In-Stack Filter Assemblies .............................................39Method 23, Deluxe Plus ..................................40Method 23, Sampler Kit Components ..............40Method 23, Coolant Pump Options .................40Method 23, Glassware ....................................40Method 23, Individual Accessories ..................40Method 26A, HCI ............................................41Method 26A, Accessories ................................41Method 29, Multiple Metals .............................42Method 29, Accessories ..................................42Monorails ........................................................60Method 201A, Particle Sizing ..........................44Method 201A, PM2.5 Cyclone Set ..................44Method 201A, Expanded Nozzle Set ...............44Method 201A, PM10 Cyclone Set ...................45Method 201A, PM10 & PM2.5 Cyclone Set .....45Method 201A, Cascade Impactor Set ..............46Method 201A, Particle Sizing Data Reduction WINCIDRS Software ......................................46Method 202, Dry Impinger ...............................47Method 202, Sampling Accessories ................48Method 202, Purge Accessories ......................48Method 0061, Hexavalent Chromium ..............48Nozzle Calibration ...........................................59Nozzles, Isokinetic Sampling ..........................14

Alumina ...........................................................54 Balances .........................................................55-56Ball & Socket Joint Adapters ...........................29-30Ball & Socket Joint Adapters, Impingers ..........29-30Calibration Equipment & Services ..................59Cases, Equipment ...........................................19Cases, Impinger ..............................................21Cases, Risers ..................................................21Cases, Modular Sample Frame .......................21Cases, Umbilical Gooseneck Adapter .............21Cases, Impinger Inlet Strain Relief ..................21Cases, Power Box Adapter .............................21Consoles, XC-5000 Automated Sampling ......4-5 Consoles, XC-522 / XC-572 Manual ..............6-9Consoles, XC-522 Accessories ......................8Consoles, XC-572 Accessories ......................9Consoles, XC-563 Digital Source Sampling ...43Consoles, XC-522 Accessories ......................8Consoles, XC-563 Digital Source Sampling ...10Consoles, XC-563 Audit Kit ............................10Consoles, Method 4 Source Sampling ………11Dessicator & Desiccants .................................53Dessicator & Desiccants, Vacuum Pump ........53Drierite Desiccants ..........................................54Filter Media .....................................................49-50Filter Ovens, Heated .......................................20Filter Ovens, Strain Reliefs ..............................20Filter Ovens, Socket Adapter ...........................20Filter Media, In-Stack Thimbles .......................50Glassware, Sets ..............................................22Glassware, Method 5 Sets ..............................22Glassware, Deluxe Method 5 Sets ..................23Glassware, Accessories ..................................23Glassware, Filter Assemblies/Components .....24Glassware, Individual & Accessories ...............25Glassware, Impinger Accessories ...................25Glassware, Cyclones ......................................25Glassware, Connectors ...................................26Glassware, Controlled Condensate .................26Glassware, Condensers ..................................27Glassware, Adapters .......................................27Glassware, Method 17 ....................................27Glassware, Method 202 ..................................28Glassware, Method 23 ....................................28

Nozzles, Sets..................................................14Nozzles, Oversized.........................................14Nozzles, Unions..............................................15Nozzles, Tube Nuts ........................................15Nozzles, Rings................................................15Nozzles, Vinyl Nozzle Caps ............................15Nozzles, Brushes............................................15Nozzles, Brush Sets .......................................15Nozzles, Ferrules............................................15Nozzles, Small Parts Kit .................................15Nozzles, Steel Alloys ......................................15Ontario-Hydro/Mercury ....................................43Ontario-Hydro/Mercury Accessories ................43Orifice Set .......................................................58Pitot Audit Equipment & Manometers ..............59Probe Assemblies, Method 5 ..........................16Probe Assemblies, Packing Gland .................16Probe, Method 5 Tube Heaters .......................16Probe, Replacement Pitot Tips .......................16Probe Liners ...................................................17Probe Liners, Tubing ......................................17Probe Liners, Adapters ...................................17Probe Sheaths, Method 5 Inconel ..................18Probe Sheaths, Method 5 Stainless Steel .......18Probe Sheaths, Air Cooled Method 5 ..............18Probe Sheaths, Alloy Method 5 .......................18Probe Sheaths, Blowers ..................................18Pump Assemblies, Method 5..........................12Pump Frame, Optional XF-05HW...................12Pumps, Lubricated Rotary Vane .....................12 Pumps, Lubricated Rotary Vane .....................12 Pumps, Diaphragm .........................................13Sample Lines, Heated .....................................32Sample Lines, Unheated Jumpers ..................32Sample Lines, Strain Relief .............................32Sample Recovery ............................................51Sample Recovery, Accessories .......................52Sample Recovery, Bottles ...............................52Silica Gel .........................................................54Umbilical Cables, Split Back ............................31Umbilical Cables, Classic ................................31Umbilical Cables, Classic Adapters .................31Umbilical Cables, Accessories .........................31Wet Test Meters ..............................................58

Isokinetic

Page 69: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

TERMS ANd CONdITIONS

PRICES ANd TERMSOur prices are subject to change without notice. The price in effect when we receive your order will apply. All prices are Ex Works Holly Springs, North Carolina. We will be pleased to furnish quotations by phone, fax or e-mail. Terms of payment are Net 30 days with established credit, or by Visa/MasterCard/American Express at time of order. Invoices over 30 days past due are subject to 1.5% per month finance charge.

CONFIRMING ORdERSPlease make sure that all confirming orders are clearly marked to avoid duplicate orders.

ShIPMENTS ANd dELIVERYUnless otherwise instructed, shipments are made as soon as possible after receipt of order by method of transportation which in our judgement will be most satisfactory. Freight charges are prepaid and added to the invoice. The right is reserved to make partial shipments where delays beyond our control may delay a portion of the order.

EXPORT PROCESSING ANd PRICINGPrices do not include customs and duty charges, freight, insurance, export fees, bank wire transaction fees or any additional handling fees.

RETURNEd ITEMSAuthorization must be obtained from us before returning any goods. When requesting return authorization, please advise reason for return, date of purchase, your P.O. number and our invoice number. Equipment produced to special specifications are not returnable. All returns must be shipped freight prepaid at the purchasers expense and are subject to a restocking fee.

LIMITEd WARRANTYAPEX INSTRUMENTS, INC. warrants products to be free from defects in workmanship for a period of one year from date of delivery. The sole and exclusive remedy for defective goods shall be to repair or replace defective parts or payment price of the goods for which damages are claimed at APEX INSTRUMENTS, INC.’s option. Freight for return of defective items will be at the sole discretion of APEX INSTRUMENTS, INC. Except as described in our guarantee, there are no express warranties or implied warranties including, but not limited to, merchantability and fitness for a particular purpose. APEX INSTRUMENTS, INC. shall not be subject to and disclaims: (1) any other obligations or liabilities arising out of breach of contract or warranty, (2) any obligations whatsoever arising from tort claims (including negligence and strict liability) or arising under other theories of law with respect to products sold or services rendered by APEX INSTRUMENTS, INC., or any undertakings, acts or omissions relating thereto, and (3) all consequential, incidental and contingent damages whatsoever.

dESIGN ChANGESDesign changes are made from time to time. Some items may differ slightly from catalog illustrations or descriptions. Changes are made in the interest of better performance and quicker delivery.

ACCEPTANCE OF TERMS ANd CONdITIONSAPEX INSTRUMENTS, INC. sells products only under foregoing terms and conditions and will not be bound to terms and conditions stated by any purchaser in any offer, acceptance or other contractual document. Placing an order or accepting delivery of products constitutes acceptance of terms and conditions.

Great care has been taken in preparation of this literature, however, we cannot be responsible for any omissions or typographical errors.

APEx INSTrUMENTS, INC.Solutions for Source Sampling EquipmentApex Instruments is a world leader in the manufacture, design and distribution of source sampling equipment. Our products are used in a wide variety of sampling scenarios. Our equipment complies with emissions measurement standards for stationary combustion sources in accordance with US EPA guidelines. We are located approximately 20 miles from the United States Environmental Protection Agency in Research Triangle Park, N.C. Our goal is to provide you with the proper, well engineered equipment in order for your job to run smoothly and have consistent, accurate and reliable results.

teChniCal serViCesApex Instruments understands the needs and high demands of the individuals working in the source sampling industry. The primary end users of our equipment consist of government agencies, consulting firms and private industries throughout North America and in 50 countries around the globe. Our knowledgeable staff includes many skilled industry professionals, stack testers and chemists. They all will help you make important decisions regarding your specific ap-plication needs.

CaliBration serViCesApex Instruments offers dedicated, climate controlled, precision calibration services for a variety of measuring instruments. This includes gas meters, orifices and pitot tubes to help keep all your calibration equipment up-to-date. Our trained staff will utilize the reliable calibration equipment and tools such as NIST Certified Bell Prover, wet test meters, electronic flow calibrators and wind tunnels. We offer a certification of calibration when requested.

Custom FaBriCation and assemBlYApex Instruments’ custom-designed facility was built in 2005. The warehouse layout provides a smooth flow for the assembly and fabrication departments. We can design, build and expedite all equipment orders quickly through our in-house engineering, production and welding departments. Apex continues with their steady commitment to quality in compliance testing, by consistently designing and developing reliable source sampling equipment. We follow guidelines set by U.S. EPA Reference Methods and always keeping the genuine needs of the stack samplers in mind.

aWardsApex Instruments recently received the (SHARP) Safety and Health Achievement Award from the NC (DOL) Department of Labor. This program recognizes small to medium size businesses that establish and maintain effective safety standards and health programs. We were also ranked in the top 500 by Inc. Magazine as being one of the fastest growing privately held companies.

Page 70: Catalogo Isocineticos APEX 1-01-12 NP SIAFAweb

XC-522

XC-5000

XC-40

Publication:Date Issued:

PEC-Isokinetic1-01-12

IsokInetIcequIpmentcatalog

Av. Juan Bautista Alberdi 5283 1°PCiudad Autónoma de Buenos AiresTel: +54 11 4684 2232http://[email protected]