164
Prices and specifications 04/2013 ROTEX Products 2013

Catalog Rotex 2013

Embed Size (px)

Citation preview

  • Prices and specifications 04/2013

    ROTEX Products 2013

  • 22

    Heat pump 4

    Boiler 36

    Flue gas systems 52

    Thermal store 96

    Solar heating system 110

    Heat distribution 124

    Installation system 142

    Fuel oil tanks 150

    Rainwater storage tanks 158

  • Index

    The pricelist is valid from 01/04/2013 to 31/03/2014. All prices excl. VAT. Technical changes reserved.

    An overview of ROTEX spare parts is available at www.rotex-heating.com > Service > Spare Parts.

    Heat pump HPSU 4HPSU compact 6HPSU Bi Bloc 12HPSU monobloc 16HPSU hitemp 20HybridCube 31

    Technical dataHPSU compact HPSU compact H/C Biv 23HPSU compact HPSU compact H/C 24G-plus 26HPSU indoor unit LT Bi-Bloc 26HPSU outdoor unit LT Bi-Bloc 27HPSU monobloc 29HPSU indoor unit /outdoor unit HT Bi-Bloc 30HP convector 31HybridCube 35

    Boiler 36A1 oil condensing 36A1 gas condensing 40GCU compact 42Gas condensing wall-mounted boiler GW 48Flue gas systems 52

    Technical dataA1 oil/gas condensing boiler 41GCU compact 46Gas condensing wall-mounted boiler GW 50

    Thermal store 96Sanicube / HybridCube 96

    Technical dataSanicube / HybridCube 104

    Solar heating system 110Material combinations 111Solaris 115

    Technical dataSolaris 121

    Heat distribution 124Monopex, System 70 124Room controller 133

    Installation system 142VA Installation system 142

    Fuel oil tanks 150Variosafe 152VA-Oil 156Variosystem / highcube 157

    Rainwater storage tanks 158Variocistern 158

    General Business Terms 159Our offices in Europe 160

    3

  • 4Hea

    t pum

    pHeat pump

    Overview

    ROTEX heat pump HPSU compact H/C Biv HPSU compact H/C

    Heat pump for maximum flexibility:Combination with solar (pressurised solar or drain-

    back) and second heat generator

    Heat pump for combination with solar(ROTEX Solaris Drain Back)

    SGReady

    Smart Heat Pumps

    Maximum inflow temperature 55 C

    New-build applications

    Existing building underfloor heating orLow-temperature radiators (50 C)

    Existing buildings with radiators above 50 C

    Bivalency option integratedsecond heat generator can be connected

    Heating and hot water

    Combination with solar (can also be retro-fitted)

    Combination with second Heat generator (can also be retro-fitted)

    Cooling (Comfort 365)

    The components

    External unit

    Internal unit

    Hygienic storage facility with solar option

    Stainless steel storage tank

    Standard not available

    The SG Ready label is issued exclusively in Germany. It indicates that the control technology of the individual heat pump allows incorporation of an intelligent mains power network.

    SGReady

    Smart Heat Pumps

  • 5Hea

    t pum

    p

    Heat pump

    ROTEX heat pump HPSU Bi Bloc HPSU monobloc HPSU hitemp

    Maximum inflow temperature 55 C 80 C

    New-build applications

    Existing building underfloor heating orLow-temperature radiators (50 C)

    Existing buildings with radiators above 50 C

    Bivalency option integratedsecond heat generator can be connected

    Heating and hot water

    Combination with solar (can also be retro-fitted)

    /

    Cooling (Comfort 365)

    The components

    External unit

    Internal unit

    Hygienic storage facility with solar option

    Stainless steel storage tank

    Standard optional when using the HybridCube

    not available

    4kW 6kW 8kW 11kW 14kW 16kW

    HPSU compact 304 H/C Biv & 304 H Biv

    HPSU compact 308 H/C Biv & 308 H Biv

    HPSU compact 508 H/C Biv & 508 H Biv

    HPSU compact 516 H/C Biv & 516 H Biv

    HPSU compact 304 H/C & 304 H

    HPSU compact 308 H/C& 308 H

    HPSU compact 508 H/C & 508 H

    HPSU compact 516 H/C & 516 H

    HPSU Bi Bloc

    HPSU monobloc

    HPSU hitemp

    Size available Size not available

    Overview

    5

  • 6Heat pumpH

    eat p

    ump

    Air-to-water heat pump, HPSU compactLow Temperature

    ROTEX HPSU compactt 4QMJUTZTUFNDPOTJTUJOHPGPVUEPPSVOJUJOEPPSVOJUXJUIJOUFHSBUFEFOFSHZTUPSBHFUBOLt 'PSIPUXBUFSBOEIFBUJOHt -PX5FNQFSBUVSFNBYJNVNGMPXUFNQFSBUVSF$t 0VUQVUTQFDUSVNUPL8t 0VUQVUNPEVMBUJOHPQFSBUJPOJOWFSUFSUFDIOPMPHZt $POUFOUPGTUPSBHFUBOLPSMJUSFTt *OUFHSBUFETPMBSPQUJPO%SBJO#BDL

    t )FBUJOHBOEDPPMJOHt *4.*OUFMMJHFOU4UPSBHF.BOBHFNFOU

    t *OUFHSBUFEPWFSGMPXWBMWFt 4NBSU(SJE3FBEZt *OUFHSBUFEFMFDUSPOJDDPOWFOJFODFDPOUSPMMFS305&93P$PO# - Simple and consistent handling for ROTEX A1, GCU compact and HPSU compact - Clear text display with multi-coloured background lighting for visualisation of status and

    error messages - Intuitive menu guidingAdditional features for Version Biv:t #JWBMFODZPQUJPOGPSJOUFHSBUJPOPGBOBEEJUJPOBMIFBUTPVSDFPSBQSFTTVSJTFETPMBSTZTUFN#JW

    SGReady

    Smart Heat Pumps

    Lo

    w T

    em

    pe

    ratu

    re

  • 7Split air -to- water heat pumps up to 55 C flow Type Order No. Price

    HPSU compact 304 H/C Biv or 308 H/C BivFor outdoor units 4 kW, 6 kW, 8 kW (heating and cooling). Indoor unit with integrated 300 l energy store for hygienic hot water generation on the instantaneous throughput principle. Hydraulically equipped with a high-efficiency pump, diverter valves for hot water / heating and heating / cooling with integrated return flow temperature limitation for solar use, integrated overflow, safety module with electonic pressure gauge and safety valve, flow sensor and filling and draining cocks. Additional pressurised heat exchanger for solar applications or external heat generators. Electrical equipment with load relay and prepared plug-and-play connection for electric auxiliary heating / process water heating (9 kW).This immersion heater should be ordered separately.Dimensions (B x T x H) 595 x 615 x 1945 mm.

    HPSU compact 304 H/C Biv 4 kWHPSU compact 308 H/C Biv 6 8 kW

    14 15 3414 15 35

    3.807,004.129,00

    HPSU compact 508 H/C Biv or 516 H/C BivFor outdoor units 6 kW, 8 kW, 11 kW, 14 kW, 16 kW (heating and cooling). Indoor unit with integrated 500 l energy store for hygienic hot water generation on the instantaneous through-flow principle. Hydraulically equipped with a high-efficiency pump, diverter valves for hot water / heating and heating / cooling with integrated return flow temperature limitation for solar use, integrated overflow, safety module with electonic pressure gauge and safety valve, flow sensor and filling and draining cocks. Additional pressure heat exchanger for solar applications or external heat generators. Electrical equipment with load relay and prepared plug-and-play connection for electric auxiliary heating / process water heating (9 kW). Please order this immersion heater separately. Dimensions (W x D x H) 790 x 790 x 1951 mm.

    HPSU compact 508 H/C Biv 6 8 kWHPSU compact 516 H/C Biv 11 16 kW

    14 15 3614 15 37

    4.769,004.999,00

    HPSU compact 304 H/C or 308 H/C For outdoor units 4 kW, 6 kW, 8 kW (heating and cooling). Indoor unit with integrated 300 l energy store for hygienic hot water generation on the instantaneous throughput principle. Hydraulically equipped with a high-efficiency pump, diverter valves for hot water / heating and heating / cooling with integrated return flow temperature limitation for solar use, integrated overflow, safety module with electonic pressure gauge and safety valve, flow sensor and filling and draining cocks. Electrical equipment with load relay and prepared plug-and-play connection for electric auxiliary heating / process water heating (9 kW). This immersion heater should be ordered separately. Dimensions (B x T x H) 595 x 615 x 1945 mm.

    HPSU compact 304 H/C 4 kWHPSU compact 308 H/C 6 8 kW

    14 15 3014 15 31

    3.549,003.849,00

    HPSU compact 508 H/C or 516 H/CFor outdoor units 6 kW, 8 kW, 11 kW, 14 kW, 16 kW (heating and cooling). Indoor unit with integrated 500 l energy store for hygienic hot water generation on the instantaneous through-flow principle. Hydraulically equipped with a high-efficiency pump, diverter valves for hot water / heating and heating / cooling with integrated return flow temperature limitation for solar use, integrated overflow, safety module with electonic pressure gauge and safety valve, flow sensor and filling and draining cocks. Electrical equipment with load relay and prepared plug-and-play connection for electric auxiliary heating / process water heating (9 kW). This immersion heater should be ordered separately. Dimensions (B x T x H) 790 x 790 x 1,951 mm.

    HPSU compact 508 H/C 6 8 kWHPSU compact 516 H/C 11 16 kW

    14 15 3214 15 33

    4.459,004.679,00

    Hea

    t pum

    p

    Heat pump

    Air-to-water heat pump, HPSU compactLow Temperature

    Lo

    w T

    em

    pe

    ratu

    re

    7

  • 8Heat pumpH

    eat p

    ump

    Air-to-water heat pump, HPSU compactLow Temperature

    Lo

    w T

    em

    pe

    ratu

    re

    Split air -to- water heat pumps up to 55 C flow Type Order No. Price

    HPSU compact 304 H Biv or 308 H BivFor outdoor units 4 kW, 6 kW, 8 kW (heating). Indoor unit with integrated 300 l energy store for hygienic hot water generation on the instantaneous throughput principle. Hydraulically equipped with a high-efficiency pump, diverter valves for hot water / heating and heating with integrated return flow temperature limitation for solar use, integrated overflow, safety module with electonic pressure gauge and safety valve, flow sensor and filling and draining cocks. Additional pressurised heat exchanger for solar applications or external heat generators. Electrical equipment with load relay and prepared plug-and-play connection for electric auxiliary heating / process water heating (9 kW).This immersion heater should be ordered separately.Dimensions (B x T x H) 595 x 615 x 1945 mm.

    HPSU compact 304 H Biv 4 kWHPSU compact 308 H Biv 6-8 kW

    14 15 4214 15 43

    3.757,004.079,00

    HPSU compact 508 H Biv or 516 H BivFor outdoor units 6 kW, 8 kW, 11 kW, 14 kW, 16 kW (heating). Indoor unit with integrated 500 l energy store for hygienic hot water generation on the instantaneous through-flow principle. Hydraulically equipped with a high-efficiency pump, diverter valves for hot water / heating and heating with integrated return flow temperature limitation for solar use, integrated overflow, safety module with electonic pressure gauge and safety valve, flow sensor and filling and draining cocks. Additional pressure heat exchanger for solar applications or external heat generators. Electrical equipment with load relay and prepared plug-and-play connection for electric auxiliary heating / process water heating (9 kW). Please order this immersion heater separately. Dimensions (W x D x H) 790 x 790 x 1951 mm.

    HPSU compact 508 H Biv 6 8 kWHPSU compact 516 H Biv 11 16 kW

    14 15 4414 15 45

    4.719,004.949,00

    HPSU compact 304 H or 308 H For outdoor units 4 kW, 6 kW, 8 kW (heating). Indoor unit with integrated 300 l energy store for hygienic hot water generation on the instantaneous throughput principle. Hydraulically equipped with a high-efficiency pump, diverter valves for hot water / heating and heating with integrated return flow temperature limitation for solar use, integrated overflow, safety module with electonic pressure gauge and safety valve, flow sensor and filling and draining cocks. Electrical equipment with load relay and prepared plug-and-play connection for electric auxiliary heating / process water heating (9 kW). This immersion heater should be ordered separately. Dimensions (B x T x H) 595 x 615 x 1945 mm.

    HPSU compact 304 H 4 kWHPSU compact 308 H 6 8 kW

    14 15 3914 15 40

    3.499,003.799,00

    HPSU compact 508 H or 516 HFor outdoor units 6 kW, 8 kW, 11 kW, 14 kW, 16 kW (heating). Indoor unit with integrated 500 l energy store for hygienic hot water generation on the instantaneous through-flow principle. Hydraulically equipped with a high-efficiency pump, diverter valves for hot water / heating and heating with integrated return flow temperature limitation for solar use, integrated overflow, safety module with electonic pressure gauge and safety valve, flow sensor and filling and draining cocks. Electrical equipment with load relay and prepared plug-and-play connection for electric auxiliary heating / process water heating (9 kW). This immersion heater should be ordered separately. Dimensions (B x T x H) 790 x 790 x 1,951 mm.

    HPSU compact 508 H 6 18 kWHPSU compact 516 H 11 16 kW

    14 15 4114 15 38

    4.409,004.629,00

  • 9Hea

    t pum

    p

    Heat pump

    Lo

    w T

    em

    pe

    ratu

    re

    Regulation accessories Type Order No. Price

    Room controllerConvenience controller with wall-mounting for use asa) A remote control (external equipment controller)b) Mixer unit (additional or standalone)c) Room thermostat for heat exchanger

    RoCon U1 15 70 34 159,00

    Option 1: Cabled room thermostat

    Option 2: Wireless Room Thermostat

    RKRTW

    RKRTR

    14 10 03

    14 10 04

    149,00

    289,00

    Mixer moduleController for mixer valve with speed-controlled high-efficiency pump including mixer circuit sensora) in combination with an equipment controller (RoCon B1).Mixer parameters adjustable via the heat generator.b) in combination with room controller (RoCon U1)1. can be used as a standalone solution2. can be integrated in the system via BUS

    RoCon M1 15 70 68 169,00

    Outdoor sensor for RoCon convenience regulation RoCon OT1 15 60 70 29,00

    Backup heaterAdditional heating for HSPU compact.Electric immersion heater 3 x 230 V 50 Hz / 9000 Watt to support the heat pump as a back-up and booster heater. 1000mm long.Plug-and-play installation, ready to plug in.

    BU9c 14 10 28 410,00

    G-plusWall-mounted gas condensing unit, room-air independent.3.5 - 15 kW to support the HPSU compact heat pump.Instead of the electrical auxiliary heating, the condensing unit can be used as a backup and booster heater. Actuation is by the intelligent HPSU compact controller. ROTEX G-plus is supplied ready for connection, with integrated circulation pump, automatic vent and installation kit. The connection kit G-plus (Item No. 16 01 28) is available for the connection of the condensing unit to the HSPU compact.Dimensions (W x D x H) 340 x 340 x 640 mm; weight 25 kg.

    G-plus 14 07 00 1.654,00

    G-plus storage tank connection(storage tank return connection and electric immersion heater connection)Kit for connecting the G-plus gas condensing unit to the HSPU compact. Consists of: piping, fittings, storage tank incorporation, Communication line and double-wall reducer 80 / 60 cm. Unpressurised mode.

    SAG-plus 16 01 28 210,00

    Storage tank incorporation heat exchanger Variant 2 (storage tank return connection and electric immersion heater connection)Kit for connecting a wood-burning, pellet, oil or gas boiler the HSPUcompact or a ROTEX storage tank (compatible for all models from 2013) as an alternative to an immersion heater. Consists of: piping, fittings, storage tank incorporation and circulation pump. For the connection of a boiler to the unpressurised area, you will need an additional plate heat exchanger (e.g. ROTEX RPWT1 Order No. 16 20 31). This variant can only be realised with controllable heat generators.

    SAK 16 01 27 263,00

    Boiler incorporation A1(storage tank return connection and electric immersion heater connection)Kit for connecting of a ROTEX A1 condensing boiler for bivalent operation with an HPSU compact. Consists of: piping, fittings, storage tank incorporation. Unpressurised mode.

    SAA1 16 01 25 144,00

    Air-to-water heat pump, HPSU compactLow Temperature

    9

  • 10

    Heat pumpH

    eat p

    ump

    Lo

    w T

    em

    pe

    ratu

    re

    Article Type Order No. Price

    Hydraulic diverter DN 125 for HSPU compact,HPSU Bi-Bloc and HPSU hitemp

    Consisting of DN125 round pipe sub-divided into four zones (using perforated separator discs, length approx. 1550 mm), equipped with 8 x heating circuit connections 1 male thread, and a 1 x sleeve and standing foot. Max. permissible operating pressure: 6 bar, max. permissible temperature: 110 C.

    HWC 17 29 00 489,00

    Thermal insulation for hydraulic diverterThermal insulation in accordance with EnEV, consisting of 60 mm PUR foam in a sheet steel casing.

    WHWC 17 29 01 309,00

    Mixer group for all ROTEX heat generators For a mixed heating circuit. Ready to plug in, in the thermal insulation case, with pressure controlled high-efficiency circulation pump, motor mixer, stops valves and temperature displays.

    MK1 15 60 67 799,00

    Mixer group for all ROTEX heat generatorsFor a mixed heating circuit.Ready to plug in, in the thermal insulation case, with PWM-controlled high-efficiency circulation pump, motor mixer, stops valves and temperature displays. (Available from June 2013)

    MK2 15 60 72 799,00

    Fittings kit for mixer group MK1 female thread x 1 1 / 2 flat-sealing.

    VMK1 15 60 53 21,00

    Sludge and magnetic separatorCompact sludge separator with drain cock and thermal insulation. Input G1-IG (union nut), outlet G1-lG.

    SAS1 15 60 21 199,00

    Burner blocking contact connection cableFor RPS2, RPS3, RPS3 M, RPS3 25 M.

    BSKK 16 41 10 16,80

    Air-to-water heat pump, HPSU compactLow Temperature

  • 11

    Hea

    t pum

    p

    Heat pump

    Lo

    w T

    em

    pe

    ratu

    re

    11

  • 12

    Air-to-water heat pump, HPSU Bi-BlocLow Temperature

    ROTEX HPSU Bi-Bloct 4QMJUTZTUFNDPOTJTUJOHPGFYUFSOBMVOJUBOEJOUFSOBMVOJUt 'PSIPUXBUFSIFBUJOHBOEDPPMJOHt -PX5FNQFSBUVSFNBYJNVNGMPXUFNQFSBUVSF$t 0VUQVUTQFDUSVNUPL8t 0VUQVUNPEVMBUJOHPQFSBUJPOJOWFSUFSUFDIOPMPHZt 'PSDPNCJOBUJPOXJUIUIFFOFSHZTUPSF305&9)ZCSJE$VCFTFFQBHFt $BOCFTFMFDUFEXJUITPMBSPQUJPOJODPNCJOBUJPOXJUI305&9)ZCSJE$VCF

    Hea

    t pum

    pHeat pump

    EU Environ-mental Labelfor HPSU in combination with under-floor heating

    Lo

    w T

    em

    pe

    ratu

    re

  • 13

    Air-to-water heat pump, HPSU Bi-BlocLow Temperature

    Hea

    t pum

    p

    Heat pump

    Accessories Type Order No. Price

    Option 1: Cabled room thermostat

    Option 2: Wireless Room Thermostat

    RKRTW

    RKRTR

    14 10 03

    14 10 04

    149,00

    289,00

    Screed temperature sensor EKRTETS 14 10 36 29,00

    E-Pac LT switching unitSwitching unit for mounting on the HybridCube energy storage unit (300 l, 500 l). Includes three-way switching valve, connection cable and storage tank sensor. Required for connecting the HybridCube energy storage unit to the HPSU. Please order the immersion heater separately if you want additional heating output.

    EP LT 3H (for 300 L HYC, HPSU heating/heating and cooling)EP LT 5H (for 500 l HYC, HPSU only heating)EP LT 5X (for 500 L HYC, HPSU heating and cooling)

    DVCPLT3H / XDVCPLT5HDVCPLT5X

    14 10 6214 10 60 14 10 61

    259,00459,00609,00

    Storage tank sensor for HPSU LT Bi-BlocFor use if no E-Pac is being used and the heat pump is directly connected to the storage tank (by customer).

    SF LT 14 10 37 42,00

    Booster heater supplementary heating for HPSU Bi-Bloc in combination with HybridCubeElectric immersion heater 230 V-50 Hz / 3000 Watt to support the heat pumps as a booster heater. 900 mm long.

    BO3S 16 51 37 299,00

    Split air -to- water heat pumps up to 55 C flow Type Order No. Price

    ROTEX HPSU Bi-Bloc Internal UnitFor external unit 4 16 kW. Hydraulically equipped with high-efficiency pump, expansion vessel, safety module with pressure gauge and safety valve, flow monitor and filling and evacuation valves and brass dirt trap. Electrical equipment with load contactors for 3/6/9 kW auxiliary electric heating and heat circulating pump.Dimensions (W x D x H) 502 x 361 x 922 mm.

    Heating only:

    HPSU 4 kW internal unit with 3 kW electric immersion heater 1~230 V for 4 kW external unit.HPSU 8 kW internal unit with 9 kW electric immersion heater 3~400 V for 6 8 kW external unit.HPSU 16 kW internal unit with 9 kW electric immersion heater 3~400 V for 11 16 kW external unit.

    Heating and cooling:

    HPSU 4 kW internal unit with 3 kW electric immersion heater 1~230 V for 4 kW external unit.HPSU 8 kW internal unit with 9 kW electric immersion heater 3~400 V for 6 8 kW external unit.HPSU 16 kW internal unit with 9 kW electric immersion heater 3~400 V for 11 16 kW external unit.

    RHBH04CA3V

    RHBH08CA9W

    RHBH16CA9W

    RHBX04CA3V

    RHBX08CA9W

    RHBX16CA9W

    14 41 70

    14 41 71

    14 41 76

    14 41 72

    14 41 73

    14 41 75

    2.479,00

    2.799,00

    3.019,00

    2.729,00

    3.059,00

    3.309,00

    Lo

    w T

    em

    pe

    ratu

    re

    13

  • 14

    Hea

    t pum

    pHeat pump

    Air-to-water heat pump, HPSU Bi-BlocLow Temperature

    Accessories Type Order No. Price

    SOL-PAC LT/HTCommunication unit between the ROTEX HPSU Bi-Bloc / HPSU Monobloc / HPSU hitemp and ROTEX Solaris. Consisting of connecting cable and circuit board.

    Supplementary package SOLARIS Sol-Pac SOL-PAC LT/HT 14 05 38 149,00

    Burner blocking contact connection cableFor RPS2, RPS3, RPS3 M, RPS3 25 M.

    BSKK 16 41 10 16,80

    Condensate pan for Internal Unit EKHBDPCA2 14 05 40 169,00

    Return flow temperature limitation Thermal return flow temperature limitation to max. 55 C.Component required for connecting a solar system to the HPSU.Choice depends on pipework design and flow rates.

    RLB 300 with 1 male thread and Kvs 3.2 (only 6 8 kW HPSU)RLB 500 with 1 1 / 4 male thread and Kvs 9 (6 16 kW HPSU)

    RLB 300RLB 500

    14 01 1414 01 15

    108,00124,00

    3-way switch valve3-way switch valve 1 male thread with motor drive 240 V, switching time 6 sec. including connection cable 2 m.

    3-W SV 15 60 34 115,00

    Supplementary user interface for HPSU Bi-Bloc indoor unitFor direct operation at the unit, if the heat pumpcontroller (REMOCON) is used as a room thermostat

    EKRUCAL1 14 10 44 129,00

    Interface cable for configuration of the heat pump controllerVia PC, for HPSU Bi-Bloc

    RKPCCAB1 14 05 42 239,00

    Decentalised outdoor temperature sensor RKRSCA1 14 10 39 83,00

    Overflow valveOverflow valve DN 20 or DN 25 with fitting with angle body.Necessary component of an HPSU heat pump system excluding HPSUcompact, in order to the minimum flow rate on the internal unit.

    UESV 20UESV 25

    14 01 1114 01 16

    82,00109,00

    Hydraulic diverter DN 125 for HSPU compact,HPSU Bi-Bloc and HPSU hitemp

    Consisting of DN125 round pipe sub-divided into four zones (using perforated separator discs, length approx. 1550 mm), equipped with 8 x heating circuit connections 1 male thread, and a 1 x sleeve and standing foot. Max. permissible operating pressure: 6 bar, max. permissible temperature: 110 C.

    HWC 17 29 00 489,00

    Thermal insulation for hydraulic diverterThermal insulation in accordance with EnEV, consisting of 60 mm PUR foam in a galvanised sheet steel casing.

    WHWC 17 29 01 309,00

    Sludge and magnetic separatorCompact sludge separator with drain cock and thermal insulation. Input G1-IG (union nut), outlet G1-lG.

    SAS 1 15 60 21 199,00

    Lo

    w T

    em

    pe

    ratu

    re

  • 15

    Hea

    t pum

    p

    Heat pump

    External unit Low TemperatureAir-to-water heat pump, HPSU compact and HPSU Bi-Bloc

    Split air -to- water heat pumps up to 55 C flow Type Order No. Price

    ROTEX HPSU compact / HPSU Bi-Bloc External unit 4 8 kW(Heating and cooling) Inverter split heat pump external unit as an inverter-controlled compressor- / evaporator unit with extended modulation range. Accommodated in a weatherproof, galvanized sheet steel housing, primed, synthetic resin and powder coated. Application range: Heating to -25 C external temperature. Dimensions (B x T x H) 825 x 300 x 735 mm.

    HPSU Bi-Bloc 4 kW External unit 1~230 VHPSU Bi-Bloc 6 kW External unit 1~230 VHPSU Bi-Bloc 8 kW External unit 1~230 V

    RRLQ004CAV3RRLQ006CAV3RRLQ008CAV3

    14 51 5114 51 5214 51 53

    1.520,001.596,002.389,00

    ROTEX HPSU compact / HPSU Bi-Bloc External unit 11 16 kW(Heating and cooling) Inverter split heat pump external unit as an inverter-controlled compressor- / evaporator unit with extended modulation range. Accommodated in a weatherproof, galvanized sheet steel housing, primed and synthetic resin and powder coated. Application range heating to -25 C external temperature. Dimensions (B x T x H) 900 x 320 x 1,345 mm.

    HPSU Bi-Bloc 11 kW external unit 3~400 VHPSU Bi-Bloc 14 kW external unit 3~400 VHPSU Bi-Bloc 16 kW external unit 3~400 V

    HPSU Bi-Bloc 11 kW external unit 1~230 V HPSU Bi-Bloc 14 kW external unit 1~230 VHPSU Bi-Bloc 16 kW external unit 1~230 V

    RRLQ011CAW1RRLQ014CAW1RRLQ016CAW1

    RRLQ011CAV3 RRLQ014CAV3 RRLQ016CAV3

    14 51 4814 51 4914 51 50

    14 51 45 14 51 46 14 51 47

    3.999,004.449,004.889,00

    3.649,003.999,004.399,00

    Accessories Type Order No. Price

    Wall bracketWall bracket for mounting the external unit, including rubber buffer for noise de-coupling.

    Wall bracket for 4 8 kW external unitWall bracket for 11 16 kW external unit

    WKS 1WKS 2

    14 05 0514 05 28

    108,00169,00

    Standing bracketOptional, for external units 11 16 kW Dimensions (B x T x H) 120 x 64 x 30 cmWeight 25 kg.

    SKS 14 05 32 420,00

    Mounting feet, optional, for external units 4 8 kW,Height 10 cm recommended for socket and wall bracket mounting

    EKFT008CA 14 05 41 119,00

    Drain pan for 4 8 kW external unitWith central drain for collecting and removal of the melt water.

    EKDP008CA 14 05 33 159,00

    Heater for drain pan trough for 4 8 kW external unit EKDPH008CA 14 05 34 239,00

    Article Size VPE Order No. Price

    Coolant line copper tharmally insulated. The thermal insulation of the coolant line meets Euro Class E (fire behaviour / material class) in accordance with DIN EN 13501-1.

    Copper thermally insulatedCopper thermally insulatedCopper thermally insulatedCopper thermally insulatedCopper thermally insulatedCopper thermally insulated

    1 / 41 / 43 / 83 / 85 / 85 / 8

    12 m 25 m 12 m 25 m 12 m 25 m

    14 31 3314 31 3914 31 3414 31 4014 31 3514 31 41

    94,00139,00134,00199,00192,00339,00

    Lo

    w T

    em

    pe

    ratu

    re

    15

  • 16

    Heat pumpHeat pump

    Air-to-water heat pump, HPSU monoblocLow Temperature

    ROTEX HPSU monobloct 4PMPVOJUGPSJOTUBMMBUJPOPVUEPPSTJOTUBMMBUJPOXJUIPVUDPPMBOUMJOF

    t 'PSIPUXBUFSBOEIFBUJOHt -PX5FNQFSBUVSFNBYJNVNGMPXUFNQFSBUVSF$t 0VUQVUTQFDUSVNUPL8t 0VUQVUNPEVMBUJOHPQFSBUJPOJOWFSUFSUFDIOPMPHZt 'PSDPNCJOBUJPOXJUIUIFFOFSHZTUPSF305&9)ZCSJE$VCFTFFQBHFt $BOCFTFMFDUFEXJUITPMBSPQUJPOJODPNCJOBUJPOXJUI305&9)ZCSJE$VCFt )FBUJOHBOEDPPMJOH

    Hea

    t pum

    pL

    ow

    Te

    mp

    era

    ture

  • 17

    Heat pump

    Air-to-water heat pump, HPSU monoblocLow Temperature

    Heat pump

    Hea

    t pum

    pL

    ow

    Te

    mp

    era

    ture

    Air -to- water heat pumps monobloc up to 55 C flow Type Order No. Price

    ROTEX HPSU monobloc

    Heating and cooling

    HPSU monobloc 11 kW X 3~400 VHPSU monobloc 16 kW X 3~400 VHPSU monobloc 11 kW X 1~230 VHPSU monobloc 16 kW X 1~230 V

    RBLQ011AA6W1RBLQ016AA6W1 RBLQ011AA6V3 RBLQ016AA6V3

    14 31 7614 31 78 14 31 73 14 31 75

    7.649,008.599,007.085,007.850,00

    Accessories Type Order No. Price

    Option 1: Cabled room thermostat

    Option 2: Wireless Room Thermostat

    RKRTW

    RKRTR

    14 10 03

    14 10 04

    149,00

    289,00

    Screed temperature sensor EKRTETS 14 10 36 29,00

    E-Pac LT switching unitSwitching unit for mounting on the HybridCube energy storage unit (300 l, 500 l). Includes three-way switching valve, connection cable and storage tank sensor. Required for connecting the HybridCube energy storage unit to the HPSU. Please order the immersion heater separately if you want additional heating output.

    EP LT 3H (for 300 L HYC, HPSU heating/heating and cooling)EP LT 5X (for 500 L HYC, HPSU heating and cooling)

    DVCPLT3H / XDVCPLT5X

    14 10 6214 10 61

    259,00609,00

    SOL-PAC LT/HTCommunication unit between the ROTEX HPSU Bi-Bloc / HPSU Monobloc / HPSU hitemp and ROTEX Solaris. Consisting of connecting cable and circuit board.

    Supplementary package SOLARIS Sol-Pac SOL-PAC LT/HT 14 05 38 149,00

    Connection cable for burner blocking contact for RPS2, RPS3, RPS3 M, RPS3 25 M

    BSKK 16 41 10 16,80

    Return flow temperature limitation Thermal return flow temperature limitation to max 55 C.Component required for connecting a solar system to the HPSU.Choice depends on pipework design and flow rates.

    RLB 300 with 1 male thread and Kvs 3.2 (only 6 8 kW HPSU)RLB 500 with 1 1 / 4 male thread and Kvs 9 (6 16 kW HPSU).

    RLB 300RLB 500

    14 01 1414 01 15

    108,00124,00

    3-way switch valveThree-way swithc valve 1" male thread with motor drive 240 V,Switch time 6 seconds, including 2 m connection cable.

    3-W SV 15 60 34 115,00

    17

  • 18

    Hea

    t pum

    pHeat pump

    Air-to-water heat pump, HPSU monoblocLow Temperature

    Article Type Order No. Price

    Overflow valveOverflow valve DN 25 with screw fitting in angle body.Necessary component of an HPSU heat pump system excluding HPSUcompact, in order to the minimum flow rateon the internal unit.

    UESV 25 14 01 16 109,00

    Hydraulic diverter DN 125 for HSPU compact,HPSU Bi-Bloc and HPSU hitemp Consisting of DN125 round pipe sub-divided into four zones (using perforated separator discs, length approx. 1550 mm), equipped with 8 x heating circuit connections 1 male thread, and a 1 x sleeve and standing foot. Max. permissible operating pressure: 6 bar, max. permissible tempera-ture: 110 C.

    HWC 17 29 00 489,00

    Thermal insulation for hydraulic diverterThermal insulation in accordance with EnEV, consisting of 60 mm PUR foam in a sheet steel casing.

    WHWC 17 29 01 309,00

    Sludge and magnetic separatorCompact sludge separator with drain cock and thermal insulation. Input G1-IG (union nut), outlet G1-lG.

    SAS 1 15 60 21 199,00

    Lo

    w T

    em

    pe

    ratu

    re

  • 19

    Hea

    t pum

    p

    Heat pump

    19

  • 20

    Heat pump

    Air-to-water heat pump, HPSU hitemp

    High Temperature

    ROTEX HPSU hitemp t 4QMJUTZTUFNDPOTJTUJOHPGFYUFSOBMVOJUBOEJOUFSOBMVOJUt 'PSIPUXBUFSBOEIFBUJOHt )JHI5FNQFSBUVSFNBYJNVNGMPXUFNQFSBUVSF$t 0VUQVUTQFDUSVNUPL8t 0VUQVUNPEVMBUJOHPQFSBUJPOJOWFSUFSUFDIOPMPHZt 'PSDPNCJOBUJPOXJUIUIFFOFSHZTUPSBHFVOJU305&9)ZCSJE$VCFTFFQBHFPSBTUBJOMFTTTUFFMTUPSBHFUBOLTFFQBHFt $BOCFTFMFDUFEXJUITPMBSPQUJPOJODPNCJOBUJPOXJUI305&9)ZCSJE$VCF

    Hea

    t pum

    pH

    igh

    Te

    mp

    era

    ture

  • 21

    Heat pump

    Air-to-water heat pump, HPSU hitemp

    High Temperature

    Hea

    t pum

    p

    Split air -to- water heat pumps up to 80 C flow Type Order No. Price

    ROTEX HPSU hitemp Internal unitFor external unit 11, 14 and 16 kW (Heating)Heating of internal unit. Hydraulically equipped with speed-controlled heating circulation pump, expansion vessel, safety module with pressure gauge and safety valve, filling and evacuation valves and brass dirt trap.Including external control unit which can also be used as a room thermostat. Dimensions (W x D x H) 600 x 695 x 705 mm.

    HPSUhitemp 11 kW internal unit 3~400VHPSUhitemp 14 kW internal unit 3~400VHPSUhitemp 16 kW internal unit 3~400V

    HPSUhitemp 11 kW internal unit 1~230V HPSUhitemp 14 kW internal unit 1~230VHPSUhitemp 16 kW internal unit 1~230V

    RKHBRD011ABY1RKHBRD014ABY1RKHBRD016ABY1

    RKHBRD011ABV1 RKHBRD014ABV1RKHBRD016ABV1

    14 31 8814 31 8914 31 90

    14 31 85 14 31 86 14 31 87

    4.820,004.965,005.115,00

    4.630,004.770,004.915,00

    Accessories Type Order No. Price

    Backup heater HPSU hitemp Supplementary heatingElectric supplementary heating with 230/400 V-50 Hz / 6000 Watt for HPSU hitemp for wall-mounting. Comprises backup heater with flow monitor, bleeder valve, overcurrent protection and cable bushing. For connection to the HPSU hitemp you will need the communication board RKRP1AHT.

    1-phase connection 3-phase connection

    RKBUHAA6V3 RKBUHAA6W1

    14 10 26 10 10 27

    806,00 806,00

    Communication boardRequired for the connection of max. 2 additional room thermostats (RKRTRW) or max. 2 additional self-contained mixer units.

    RKRP1AHT 14 10 11 159,00

    Supplementary user interface For direct operation at the unit, if the heat pumpcontroller (REMOCON) is used as a room thermostat.

    RKRUAHT 14 10 10 222,00

    E-Pac HT switching unitSwitching unit for mounting on the HybridCube energy storage unit (300 / 500 l). Includes three-way switch valve, connection cable and storage tank sensor. Required for connecting theHybridCube energy storage unit to the HPSU hitemp.

    EP HT 3H (for 300 l HYC)EP HT 5H (for 500 l HYC)

    EP HT 3HEP HT 5H

    14 10 4614 10 45

    239,00429,00

    SOL-PAC LT/HTCommunication unit between the ROTEX HPSU Bi-Bloc / HPSU Monobloc / HPSU hitemp and ROTEX Solaris. Consisting of connect-ing cable and circuit board.

    Supplementary package SOLARIS Sol-Pac SOL-PAC LT/HT 14 05 38 149,00

    Burner blocking contact connection cableFor RPS2, RPS3, EPS3 M, RPS3 25 M.

    BSKK 16 41 10 16,80

    3-way switch valveThree-way swithc valve 1" male thread with motor drive 240 V,Switch time 6 seconds, including 2 m connection cable.

    3-W SV 15 60 34 115,00

    Hig

    h T

    em

    pe

    ratu

    re

    21

  • 22

    Heat pumpH

    eat p

    ump

    Split air -to- water heat pumps up to 80 C flow Type Order No. Price

    ROTEX HPSU hitemp External unit (Heating)Inverter split heat pump external unit as an inverter-controlled compressor / condenser unit. Accommodated in a weatherproof, galvanized sheet steel housing, primed and synthetic resin and powder coated. Application for high temperatures up to 80 C without electrical heating. Operation of the appliance down to -25 C.Dimensions (W x D x H) 900 x 320 x 1,345 mm.

    HPSU hitemp 11 kW external unit 3~400 VHPSU hitemp 14 kW external unit 3~400 VHPSU hitemp 16 kW external unit 3~400 V

    HPSU hitemp 11 kW external unit 1~230 V HPSU hitemp 14 kW external unit 1~230 V HPSU hitemp 16 kW external unit 1~230 V

    RRRQ011AAY1RRRQ014AAY1RRRQ016AAY1

    RRRQ011AAV1 RRRQ014AAV1 RRRQ016AAV1

    14 31 8214 31 8314 31 84

    14 31 79 14 31 80 14 31 81

    4.010,004.465,004.885,00

    3.665,004.015,004.395,00

    Accessories air -to- water heat pumps up to 80 C flow Type Order No. Price

    Wall bracketWall bracket for mounting the external unit, including rubber buffer for noise de-coupling. Wall bracket external units 11 16 kW.

    WKS 2 14 05 28 169,00

    Standing bracketOptional, for external units 11 16 kW Dimensions (B x T x H) 120 x 64 x 30 cmWeight 25 kg

    SKS 14 05 32 420,00

    Air-to-water heat pump, HPSU hitemp

    High Temperature

    Hig

    h T

    em

    pe

    ratu

    re

    Accessories Type Order No. Price

    Hydraulic diverter DN 125 for HSPU compact,HPSU Bi-Bloc and HPSU hitemp Consisting of DN125 round pipe sub-divided into four zones (using perforated separator discs, length approx. 1550 mm), equipped with 8 x heating circuit connections 1 male thread, and a 1 x sleeve and standing foot. Max. permissible operating pressure: 6 bar, max. permissible temperature: 110 C.

    HWC 17 29 00 489,00

    Thermal insulation for hydraulic diverterThermal insulation in accordance with EnEV, consisting of 60 mm PUR foam in a galvanised sheet steel casing.

    WHWC 17 29 01 309,00

    Sludge and magnetic separatorCompact sludge separator with drain cock and thermal insulation. Input G1-IG (union nut), outlet G1-lG.

    SAS 1 15 60 21 199,00

  • 23

    Heat pump

    Hea

    t pum

    p

    HPSU compact (Internal unit) HPSU compact H/C Biv (HPSU compact H Biv)

    HPSU compact 304 4 kW

    HPSU compact 308 6 8 kW

    HPSU compact 508 6 8 kW

    HPSU compact 516 11 16 kW

    14 15 34 (14 15 42) 14 15 35 (14 15 43) 14 15 36 (14 15 44) 14 15 37 (14 15 45)

    Basic data

    Dimensions (W x D x H) mm 595 x 615 x 1945 595 x 615 x 1945 790 x 790 x 1951 790 x 790 x 1951

    Unit weight kg 92 92 119 121

    Operational range flow temperature (Heating) C Min: 15 / Max: 55 Min: 15 / Max: 55 Min: 15 / Max: 55 Min: 15 / Max: 55

    Operational range flow temperature (Cooling) 1) C Min: 5 / Max: 22 Min: 5 / Max: 22 Min: 5 / Max: 22 Min: 5 / Max: 22

    Operational range DHW (with EHS) C Min: 25 / Max: 80 Min: 25 / Max: 80 Min: 25 / Max: 80 Min: 25 / Max: 80

    Connection refrigerant line

    Gas lines (mm) 5 / 8 (15,9) 5 / 8 (15,9) 5 / 8 (15,9) 5 / 8 (15,9)

    Liquid line (mm) 1 / 4 (6,4) 1 / 4 (6,4) 1 / 4 (6,4) 3 / 8 (9,5)

    Storage tank data

    Total storage capacity Litres 300 300 500 500

    Max. permissible storage water temperature C 85 85 85 85

    Heat consumption at readiness and at 60 C kWh / 24 h 1,3 1,3 1,4 1,4

    Drinking water heating

    Drinking water capacity Litres 27,8 27,8 29 29

    Maximum operating pressure bar 6 6 6 6

    Material of domestic hot water heat exchanger

    stainless steel stainless steel stainless steel stainless steel

    Drinking water heat exchanger surface m 5,8 5,8 6 6

    Storage tank charging / discharging heat exchanger (stainless steel)

    Water capacity heat exchanger Litres 13,2 13,2 12,1 17,4

    Surface of charging heat exchanger m 2,7 2,7 2,5 3,5

    Pressurised solar heat exchanger (stainless steel)

    Water capacity heat exchanger Litres 4,2 4,2 12,5 12,5

    Surface of charging heat exchanger m 0,8 0,8 1,7 1,7

    Thermal output data

    Hot water volume without reheatingat 8 l / min / 12 l / min draw-off rate (TKW = 10 C / TWW = 40 C / TSP = 50 C)*

    Litres 184 / 153 184/153 324 / 282(288 / 240)**

    324 / 282(288 / 240)**

    Hot water volume without reheating at 8 l / min / 12 l / min draw-off rate (TKW = 10 C / TWW = 40 C / TSP = 60 C)*

    Litres 282 / 252 282 / 252 492 / 444 492 / 444

    Hot water volume without reheating at 8 l / min / 12 l / min draw-off rate (TKW = 10 C / TWW = 40 C / TSP = 65 C)*

    Litres 352 / 321 352 / 321 560 / 516 560 / 516

    Reheating time draw-off volume140 l -> 5820 Wh (bath draw off)

    Min. 90 45 45 25

    Reheating time draw-off volume90 l -> 3660 Wh (shower draw off)

    Min. 55 30 30 17

    Pipe connections

    Cold and hot water Inch 1" male thread 1" male thread 1" male thread 1" male thread

    Heating inflow and return flow Inch 1" female thread 1" female thread 1" female thread 1" female thread

    Technical dataair-to-water heat pump, HPSU compactLow Temperature

    * with storage tank heat exchanger completely charged, ** Storage tank only charged with heat pump without immersion heaterReheating time = The time needed to reheat the thermal store after a certain quantity of DHW has been discharged to a store temperature of 50 C 1) Only for devices heating and cooling

    Lo

    w T

    em

    pe

    ratu

    re

    23

  • 24

    Hea

    t pum

    pHeat pump

    HPSU compact (Internal unit) HPSU compact H/C (HPSU compact H)

    HPSU compact 304 4 kW

    HPSU compact 308 6 8 kW

    HPSU compact 508 6 8 kW

    HPSU compact 516 11 16 kW

    14 15 30 (14 15 39) 14 15 31 (14 15 40) 14 15 32 (14 15 41) 14 15 33 (14 15 38)

    Basic data

    Dimensions (W x D x H) mm 595 x 615 x 1945 595 x 615 x 1945 790 x 790 x 1951 790 x 790 x 1951

    Unit weight kg 87 87 114 116

    Operational range flow temperature (Heating) C Min: 15 / Max: 55 Min: 15 / Max: 55 Min: 15 / Max: 55 Min: 15 / Max: 55

    Operational range flow temperature (Cooling) 1) C Min: 5 / Max: 22 Min: 5 / Max: 22 Min: 5 / Max: 22 Min: 5 / Max: 22

    Operational range DHW (with EHS) C Min: 25 / Max: 80 Min: 25 / Max: 80 Min: 25 / Max: 80 Min: 25 / Max: 80

    Connection refrigerant line

    Gas lines (mm) 5 / 8 (15,9) 5 / 8 (15,9) 5 / 8 (15,9) 5 / 8 (15,9)

    Liquid line (mm) 1 / 4 (6,4) 1 / 4 (6,4) 1 / 4 (6,4) 3 / 8 (9,5)

    Storage tank data

    Total storage capacity Litres 300 300 500 500

    Max. permissible storage water temperature C 85 85 85 85

    Heat consumption at readiness and at 60 C kWh / 24 h 1,3 1,3 1,4 1,4

    Drinking water heating

    Drinking water capacity Litres 27,8 27,8 29 29

    Maximum operating pressure bar 6 6 6 6

    Material ofdomestic hot water heat exchanger

    stainless steel stainless steel stainless steel stainless steel

    Drinking water heat exchanger surface m 5,8 5,8 6 6

    Storage tank charging / discharging heat exchanger (stainless steel)

    Water capacity heat exchanger Litres 13,2 13,2 12,1 17,4

    Surface of charging heat exchanger m 2,7 2,7 2,5 3,5

    Pressurised solar heat exchanger (stainless steel)

    Water capacity heat exchanger Litres

    Surface of charging heat exchanger m

    Thermal output data

    Hot water volume without reheating at 8 l / min / 12 l / min draw-off rate (TKW = 10 C / TWW = 40 C / TSP = 50 C)*

    Litres 184 / 153 184 / 153 364 / 318(328 / 276)**

    364 / 318(328 / 276)**

    Hot water volume without reheating with 8l / min / 12 l / min draw-off rate(TKW = 10 C / TWW = 40 C / TSP = 60 C)*

    Litres 282 / 252 282 / 252 540 / 494 540 / 494

    Hot water volume without reheating with 8l / min / 12 l / min draw-off rate(TKW = 10 C / TWW = 40 C / TSP = 65 C)*

    Litres 352 / 321 352 / 321 612 / 564 612 / 564

    Reheating time draw-off volume140 l -> 5820 Wh (bath draw off)

    Min. 90 45 45 25

    Reheating time draw-off volume90 l -> 3660 Wh (shower draw off)

    Min. 55 30 30 17

    Pipe connections

    Cold and hot water Inch 1" male thread 1" male thread 1" male thread 1" male thread

    Heating inflow and return flow Inch 1" female thread 1" female thread 1" female thread 1" female thread

    Technical dataAir-to-water heat pump, HPSU compactLow Temperature

    * with storage tank heat exchanger completely charged, ** Storage tank only charged with heat pump without immersion heaterReheating time = The time needed to reheat the thermal store after a certain quantity of DHW has been discharged to a store temperature of 50 C 1) Only for devices heating and cooling

    Lo

    w T

    em

    pe

    ratu

    re

  • 25

    Hea

    t pum

    p

    Heat pump

    Technical dataAir-to-water heat pump, HPSU compactLow Temperature

    HPSU external unit for HPSU compact ~1 / 230 V ~1/230 V ~3 / 400 V

    4kW 6kW 8kW 11kW 14kW 16kW 11kW 14kW 16kW14 51 51 14 51 52 14 51 53 14 51 45 14 51 46 14 51 47 14 51 48 14 51 49 14 51 50

    Basic data

    Nominal heat output A-7 / W35 kW 4,37 5,29 5,53 6,0 8,3 8,0 6,0 8,3 8,0

    Nominal heat output A2 / W35 kW 3,27 4,56 5,51 7,7 9,6 10,1 7,7 9,6 10,1

    Nominal heat output A7 / W35 kW 4,4 6,22 7,78 11,8 14,8 15,3 11,8 14,8 15,3

    Nominal heat output A10 / W35 kW 1) 1) 1) 11,5 14,5 16,1 11,5 14,5 16,1

    Nominal COP A-7 / W35 2,81 2,85 2,78 2,45 2,58 2,44 2,45 2,58 2,44

    Nominal COP A2 / W35 4,02 3,68 3,54 3,29 3,22 3,15 3,29 3,22 3,15

    Nominal heat output A7 / W35 5,04 4,88 4,6 4,47 4,27 4,1 4,47 4,27 4,1

    Nominal COP A10 / W35 5,12 5,18 4,9 4,6 4,41 4,31 4,6 4,41 4,31

    Nominal EER A35 / W18 1) 3,99 3,64 3,32 2,96 2,72 3,32 2,96 2,72

    Max. heat output A-7 / W35 kW 4,6 5,3 6,4 8,8 11,7 12,3 8,8 11,7 12,3

    Max. heat output A2 / W35 kW 4,8 6,4 7,7 9,1 10,9 11,4 9,1 10,9 11,4

    Max. heat output A7 / W35 kW 5,1 8,4 10,2 11,4 14,6 16,1 11,4 14,6 16,1

    Max. heat output A10 / W35 kW 1) 1) 1) 11,9 15,0 16,5 11,9 15,0 16,5

    Max. cooling output A35 / W18 kW 5,9 7,3 8,4 15,1 16,1 16,8 15,1 16,1 16,8

    Max. cooling output A35 / W7 kW 4,5 5,5 6,4 11,7 12,6 13,1 11,7 12,6 13,1

    Dimensions of unit (W x T x H) mm 832 x 307 x 735 900 x 320 x 1345 900 x 320 x 1345

    Unit weight kg 54 / 56 114 114

    Operating range, outside temperature (heating) C Min: -25 / Max: 25 Min: -25 / Max: 35 Min: -25 / Max: 35

    Operating range, outside temperature (cooling) C Min: 10 / Max: 43 Min: 10 / Max: 46 Min: 10 / Max: 46

    Operating range, outside temperature (DHW) C Min: -25 / Max: 35 Min: -20 / Max: 35 Min: -20 / Max: 35

    Noise level Heating* dB (A) 48 48 49 51 51 52 51 51 52

    Noise level Cooling* dB (A) 48 49 50 50 52 54 50 52 54

    Noise level Heating dB (A) 61 61 62 64 64 66 64 64 66

    Noise level Cooling dB (A) 63 63 63 64 66 69 64 66 69

    Power supply, phase 1 ~ 1 ~ 3 ~

    Power supply Frequency Hz 50 50 50

    Power supply Voltage V 230 230 400

    Inrush current A 18 22 13,5

    Operating current (maximum) A 1) 34,2 16,3

    Refrigerant R410A R410A R410A

    Coolant volume (prefilled) kg 1,45 / 1,6 3,4 3,4

    Connection refrigerant line

    Gas lines (mm) 5 / 8 (15,9) 5 / 8 (15,9) 5 / 8 (15,9)

    Liquid line (mm) 1 / 4 (6,4) 3 / 8 (9,5) 3 / 8 (9,5)

    Refrigerant line length max. m 30 50 50

    Refrigerant line length min. m 3 3 3

    * at 1 m separation1) Data not available when going to press

    Lo

    w T

    em

    pe

    ratu

    re

    25

  • 26

    Heat pumpH

    eat p

    ump

    Technical dataAir-to-water heat pump, HPSU compactLow Temperature

    ROTEX G-plus gas auxiliary heating

    14 07 00

    Dimensions (W x D x H) mm 340 x 340 x 640

    Weight kg 25

    Voltage V 230

    Frequency Hz 50

    Min. output kW 3,5

    Max. output kW 15

    Max. effectiveness % 109

    Water content l 2,5

    Inflow temp. C 40 76

    Suitable for gas types 2E, 2H, 2LL, 2LLiquid gas 3P

    Optional accessories: Supplementary heating (electric immersion heater) backup heater Output kW 9

    Power supply, phase 3~*

    Power supply Frequency Hz 50

    Power supply Voltage V 400

    Operating current A 3 x 13.1

    * 1~ phase connection (3 x 230 V / 50 Hz) possible (except in Germany)

    Technical dataAir-to-water heat pump, HPSU Bi-BlocLow Temperature

    HPSU Internal unit(LT Bi-Bloc)

    HPSU LT Bi-Bloc

    4 kW 6 8 kW 11 16 kW

    14 41 70 / 14 41 72 14 41 71 / 14 41 73 14 41 76 / 14 41 75

    Heating / Heating and cooling

    Basic data

    Colour white (RAL 9010)

    Unit dimesnsions (W x D x H) mm 480 x 344 x 890

    Unit weight kg 46 48

    Operating range, flow temperature (heating) C Min: 15 / Max: 55 Min: 15 / Max: 55 Min: 15 / Max: 55 Min: 15 / Max: 55

    Connection refrigerant line

    Gas lines " (mm) 5/8 (15,9) 5/8 (15,9) 5/8 (15,9) 5/8 (15,9)

    Liquid line " (mm) 1/4 (6,4) 3/8 (9,5) 1/4 (6,4) 3/8 (9,5)

    Type Backup Heater 3V 9W

    Heating output kW 3 9

    Power supply, phase 1~ 3~

    Power supply Frequency Hz 50 50

    Power supply Voltage V 230 400

    Operating current A 13 13

    Lo

    w T

    em

    pe

    ratu

    re

  • 27

    Heat pump

    Hea

    t pum

    p

    HPSU External unit Bi-Bloc Internal unit ~1 / 230 V ~1/230 V ~3 / 400 V

    6kW 8kW 11kW 14kW 16kW 11kW 14kW 16kW

    14 51 52 14 51 53 14 51 45 14 51 46 14 51 47 14 51 48 14 51 49 14 51 50

    Basic data

    Nominal heat output A-7 / W35 kW 5,31 5,46 8,6 10,0 11,1 8,6 10,0 11,1

    Nominal heat output A2 / W35 kW 4,58 5,8 8,56 10,3 11,1 8,56 10,3 11,1

    Nominal heat output A7 / W35 kW 6 7,4 11,2 14,5 16,0 11,2 14,5 16,0

    Nominal heat output A10 / W35 kW 6,25 7,39 11,2 14,3 15,7 11,2 14,3 15,7

    Nominal COP A-7 / W35 2,84 2,71 2,75 2,65 2,64 2,75 2,65 2,64

    Nominal COP A2 / W35 3,68 3,53 3,6 3,41 3,35 3,6 3,41 3,35

    Nominal heat output A7 / W35 4,74 4,45 4,6 4,3 4,25 4,6 4,3 4,25

    Nominal COP A10 / W35 5,07 4,75 4,85 4,7 4,5 4,85 4,7 4,5

    Nominal EER A35 / W18 2) 3,45 3,42 3,32 2,96 2,72 3,32 2,96 2,72

    Max. heat output A-7 / W35 kW 5,3 6,4 8,8 11,7 12,3 8,8 11,7 12,3

    Max. heat output A2 / W35 kW 6,4 7,7 9,1 10,9 11,4 9,1 10,9 11,4

    Max. heat output A7 / W35 kW 8,4 10,2 11,4 14,6 16,1 11,4 14,6 16,1

    Max. heat output A10 / W35 kW 1) 1) 1) 1) 1) 1) 1) 1)

    Max. cooling output A35 / W18 2) kW 7,3 8,4 15,1 16,1 16,8 15,1 16,1 16,8

    Max. cooling output A35 / W7 2) kW 5,5 6,4 11,7 12,6 13,1 11,7 12,6 13,1

    Unit dimesnsions (W x D x H) mm 832 x 307 x 735 900 x 320 x 1345 900 x 320 x 1345

    Unit weight kg 56 114 114

    Operating range outdoor temperature(Heating)

    C Min: -25 / Max: 25 Min: -25 / Max: 35 Min: -25 / Max: 35

    Operating range outdoor temperature(Cooling) 2)

    C Min: 10 / Max: 43 Min: 10 / Max: 46 Min: 10 / Max: 46

    Operating range outdoor temperature(tap water)

    C Min: -25 / Max: 35 Min: -20 / Max: 35 Min: -20 / Max: 35

    Noise level Heating* dB (A) 48 49 51 51 52 51 51 52

    Noise level Cooling* 2) dB (A) 49 50 50 52 54 50 52 54

    Noise level Heating dB (A) 61 62 64 64 66 64 64 66

    Noise level Cooling 2) dB (A) 63 63 64 66 69 64 66 69

    Power supply, phase 1 ~ 1 ~ 3 ~

    Power supply Frequency Hz 50 50 50

    Power supply Voltage V 230 230 400

    Inrush current A 18 34,2 13,5

    Operating current (maximum) A 1) 16,3 16,3

    Refrigerant R410A R410A R410A

    Coolant volume (prefilled) kg 1,6 3,4 3,4

    Connection refrigerant line

    Gas lines (mm) 5 / 8 (15,9) 5 / 8 (15,9) 5 / 8 (15,9)

    Liquid line (mm) 1 / 4 (6,4) 3 / 8 (9,5) 3 / 8 (9,5)

    Refrigerant line length max. m 30 50 50

    Refrigerant line length min. m 3 3 3

    Technical dataAir-to-water heat pump, HPSU Bi-BlocLow Temperature

    * at 1 m separation1) Data not available when going to press2) Only for devices heating and cooling

    Lo

    w T

    em

    pe

    ratu

    re

    27

  • 28

    Heat pumpH

    eat p

    ump

    Technical dataAir-to-water heat pump, HPSU monoblocLow Temperature

    HPSU monobloc ~1 /230 V ~3 / 400 V

    11kW 16kW 11kW 16kW

    14 31 73 14 31 75 14 31 76 14 31 78

    Three phase with base plate heater

    Nominal heat output A-7 / W35 * kW 6,5 9,2 6,5 9,2

    Nominal heat output A2 / W35 * kW 8,1 10,7 8,1 10,7

    Nominal heat output A10 / W35 * kW 11,8 16,4 11,8 16,4

    Nominal COP A-7 / W35 * 2,5 2,4 2,5 2,4

    Nominal COP A2 / W35 * 3,1 3,1 3,1 3,1

    Nominal COP A10 / W35 * 4,6 4,3 4,6 4,3

    Nominal cooling output A35 / W18 * kW 12,85 16,73 12,85 16,73

    Nominal cooling output A35 / W7 * kW 10 13,1 10 13,1

    Nominal EER A35 / W18 * 3,332 2,72 3,332 2,72

    Nominal EER A35 / W7 * 2,71 2,28 2,71 2,28

    Max. heat output A-7 / W35 ** kW 6,5 9,2 6,5 9,2

    Max. heat output A2 / W35 ** kW 8,1 10,7 8,1 10,7

    Max. heat output A10 / W35 ** kW 11,8 16,4 11,8 16,4

    Max. cooling output A35 / W18 ** kW 12,85 16,73 12,85 16,73

    Max. cooling output A35 / W7 ** kW 10 13,1 10 13,1

    Operating range (outdoor temperature) **** HEATING C -20 ~ 35 (1)

    Cooling C 10 ~ 46

    Hot water C -20 ~ 35 (1) (2)

    Noise level *** dB (A) 48 48 48 48

    Noise level dB (A) 48 49 48 49

    Weight kg 180

    Refrigerant quantity R -410A kg 2,95

    Power supply C 3N~ / 400 V / 50 Hz

    Recommended fuses A 32 20

    Measurement conditions: Heating Ta 7 C/ - TVL 35 C (dT = 5K) - Cooling Ta 35 C - TVL1 8 C (dT = 5 K)(1) Units can reach -25 C, but this performance cannot be guaranteed.(2) Operation of the auxiliary heater from 35 C upwards* Measured in accordance with DIN EN 14511** Measured at maximum speed Compressor in accordance with Eurovent 6/C/003-2006*** Measured at a distance of 1 m**** It may be necessary for the installer to obtain and install a trace heater strip for the pipes installed

    outside the unit. If a continuous power supply cannot be guaranteed, we recommend adding glycol to the water circuit (see installation instructions).

    Lo

    w T

    em

    pe

    ratu

    re

  • 29

    Heat pump

    Hea

    t pum

    p

    Technical dataAir-to-water heat pump, HPSU hitemp

    High Temperature

    HPSU hitemp (HT Bi-Bloc) External unit Internal unit

    ~3 / 400 V ~1 / 230 V ~3 / 400 V ~1 / 230 V

    11 kW 14 kW 16 kW 11 kW 14 kW 16 kW 11 kW 14 kW 16 kW 11 kW 14 kW 16 kW

    14 31 82 14 31 83 14 31 84 14 31 79 14 31 80 14 31 81 14 31 88 14 31 89 14 31 90 14 31 85 14 31 86 14 31 87

    Performance data

    Max. heat output A2 / W65 kW 9,6 11,9 13,5 9,6 11,9 13,5 9,6 11,9 13,5 9,6 11,9 13,5

    Power consumption A2 / W65 kW 3,9 5 5,8 3,9 5 5,8

    COP A2 / W65 2,48 2,38 2,33 2,48 2,38 2,33

    Max. heat output A7 / W65 kW 11 14 16 11 14 16 11 14 16 11 14 16

    Power consumption A7 / W65 kW 3,6 4,7 5,6 3,6 4,7 5,6

    COP A7 / W65 3,08 3 2,88 3,08 3 2,88

    Dimensions

    Unit dimesnsions (W x D x H) 900 x 320 x 1345 600 x 695 x 705

    Weight

    Mass Net kg 120 147

    Mass Gross kg 130 156

    Compressor

    Motor Type Fully hermetic scroll compressor Fully hermetic scroll compressor

    Operating range

    Heating applications C -25 to +20 -25 to +20

    Domestic hot water generation C -25 to +35 -25 to +35

    Flow max. C 80

    Flow min. C 25

    HW temperature min. C 25

    HW temperature max. C 75

    Noise level

    Noise level* db (A) 52 53 55 52 53 55 43 45 46 43 45 46

    Noise level* db (A) 68 69 71 68 69 71 59 60 60 59 60 60

    Refrigerant

    Type R410A R410A and R134a

    Control Electronic expansion valve Electronic expansion valve

    Max. line length m 50

    Max. height difference m 30

    Defrost method Process inversion

    Output control Inverter controlled Inverter controlled

    Power supply Y1 V1 Y1 V1

    Phases 3~ 1~ 3~ 1~

    Frequency Hz 50 50 50 50

    Voltage V 380 415 220 240 380 415 220 240

    Power consumption

    Maximum operating current A 13,5 13,5 13,5 23,8 23,8 23,8 12,5 12,5 12,5 22,5 23,8 23,8

    Recommended fuses A 16 16 16 25 25 25 16 16 16 25 25 25

    Pump

    Nominal ESP kPa 92 88 85 92 88 85

    Power input w 87 95 101 87 95 101

    Water side

    Nominal flow rate l / min 15,8 20,1 22,9 15,8 20,1 22,9

    * at 1m separation

    Hig

    h T

    em

    pe

    ratu

    re

    29

  • 30

    Heat pumpH

    eat p

    ump

    HP convector

    Article Type Order No. Price

    HP convectorBlower convector for room heating and cooling with compact dimensions and very quiet operation. The convector can be used both for heating and cooling and is ideally suited for operation with a heat pump. It can be used both in combination with underfloor heating and a space-saving replacement for low-temperature radiators. Theremote control with integrated temperature regulation facilitates problem-free and rapid adaption to various different requirements. The integrated air filter provides clean and pleasant room air.

    HP convector 1.5 kWHP convector 2.0 kW

    RFWXV15AVEBRFWXV20AVEB

    14 20 1014 20 11

    680,00830,00

    HPc connection packageThermally insulated flexible connecting line with fittings.

    HPc-AP 14 20 12 83,00

    HPc regulation packageThis is required if the HPc is not connected via a heating circuit distributor. Includes electrical 2-way valve, section regulation valve and connecting fittings.

    HPc-RP 14 20 13 159,00

    HPc connecting cableCable for extension of the output signals of the HPSU compact for connection of a HPc with cooling and heating function or actuation of an external valve for bypassing the heating support exchanger.

    HPc-VK-1 14 20 15 32,00

    * at 1m separation ** In combination with underfloor heating (connected in the same circuit).1) 2x (1 Kit per connection side HP convector / distributor)

    Connection accessories on RMX heating circuit distributor

    With VA pipe DN 16x2.2

    t YBEBQUFSNBMFUISFBE/P (See Installation system VA page 146)

    t $MBNQJOHSJOHLJU.7/P (See accessories heating circuit distributor RMX page 130)

    Monopex pipe 14x2

    t $POOFDUJPOOJQQMFiNBMFUISFBE9i/P (See accessories heating circuit distributor RMX page 130)

    t $MBNQJOHSJOHLJU.7/P (See accessories heating circuit distributor RMX page 130) 1)

    Connection accessories on HKV heating circuit distributor

    With VA pipe DN 16x2.2

    t YBEBQUFSNBMFUISFBE/P (See Installation system VA page 146)

    t $MBNQJOHSJOHLJU&/P (See accessories heating circuit distributor HKV page 131)

    Monopex pipe 14x2

    t $POOFDUJPOOJQQMFiNBMFUISFBE9i/P (See accessories heating circuit distributor RMX page 130)

    t $MBNQJOHSJOHLJU&/P (See accessories heating circuit distributor HKV page 131) 1)

    Technical data HP convector

    HP convector RFWXV15A RFWXV20A

    14 20 10 14 20 11

    Performance data

    Heating output kW 1,5 2

    Cooling capacity kW 1,2 1,7

    Application range

    Water temperature min. C 6 / 18** 6 / 18**

    Water temperature max. C 60 60

    Dimensions

    (W x D x H) mm 700 x 210 x 600 700 x 210 x 600

    Weight kg 15 15

    Noise level

    Noise level (mid-range ventilation)*

    dB (A) 19 29

    Power supply

    Phases 1- 1-

    Frequency Hz 50 / 60 50 / 60

    Voltage V 220 240 220 240

  • 31

    Heat pump

    Hea

    t pum

    p

    Thermal store and solar storage tank, ROTEX HybridCube

    ROTEX Hygienic storage tank HYC 343 / 19 / 0-P

    HYC 544 / 19 / 0-P

    HYC 544 / 32 / 0-P

    HYC 343 / 19 / 0-DB

    HYC 544 / 19 / 0-DB

    HYC 544 / 32 / 0-DB

    Hygienic hot water generation in instantaneous through-flow principle

    Solar heating support

    Electric immersion heater

    Heat pump combinations

    HPSU Low Temp to 8 kW

    HPSU Low Temp to 16 kW

    HPSU hitemp

    HPSU monobloc

    Solar combination

    Pressurised solar combination *

    Drain-Back combination

    * If a pressurised solar combination or a bivalency solaution is to be combined with a heat pump, we can use the ROTEX compact heat pump HPSU compact Biv Variant. See pages 7, 8.

    31

  • 32

    Heat pumpH

    eat p

    ump

    HPSU thermal store and solar storage tank, ROTEX HybridCube

    Article Type Order No. Price

    HybridCube HYC 343 / 19 / 0-PHigh-performance 300 litre energy store fordomestic hot water generation.Dimensions (W x D x H) 595 x 615 x 1646 mm, weight 57 kg

    HYC 343 / 19 / 0-P 14 05 54 1.649,00

    HybridCube HYC 544 / 19 / 0-P High-performance 500 litre stratified storage tank forhot water generation and heating support.Dimensions (W x D x H) 790 x 790 x 1,658 mm, weight 87 kg

    HYC 544 / 19 / 0-P 14 05 61 1.879,00

    HybridCube HYC 544 / 32 / 0-P High-performance 500 litre stratified storage tank forhot water generation and heating support.Dimensions (W x D x H) 790 x 790 x 1,658 mm, weight 87 kg

    HYC 544 / 32 / 0-P 14 05 63 2.039,00

    HybridCube HYC 343 / 19 / 0-DBHigh-performance 300 litre energy store for hot water generation.Dimensions (W x D x H) 595 x 615 x 1,646 mm, weight 59 kg.

    HYC 343 / 19 / 0-DB 14 05 53 1.469,00

    HybridCube HYC 544 / 19 / 0-DB High-performance 500 litre stratified storage tank for hot water generation and heating support. Dimensions (W x D x H) 790 x 790 x 1658 mm, weight 87 kg.

    HYC 544 / 19 / 0-DB 14 05 60 1.679,00

    HybridCube HYC 544 / 32 / 0-DB High-performance 500 litre stratified storage tank for hot water generation and heating support. Dimensions (W x D x H) 790 x 790 x 1658 mm, weight 93 kg.

    HYC 544 / 32 / 0-DB 14 05 62 1.819,00

  • 33

    HPSU thermal store and solar storage tank, ROTEX HybridCube

    Article Type Order No. Price

    Stainless steel hot water storage tank For combination with HPSU hitemp Internal unit or HPSU Bi-Bloc(from Version BB of internal unit). With HPSU hitemp Mounting on the internal unit is possible. With individual installation next to the internal unit you will need the mounting unit RKFMAHT for the HPSU hitemp.For installation in combination with the HPSU Bi-Bloc you will need the RKFMALTA kit.

    With a capacity of 200 litres Dimensions (W x D x H) 600 x 695 x 1,335 mm, weight 70 kg.

    With a capacity of 260 litres Dimensions (W x D x H) 600 x 695 x 1,610 mm, weight 78 kg.

    RKHTS200AC

    RKHTS260AC

    14 05 10

    14 05 11

    1.755,00

    1.999,00

    Hot water storage tank installation kitFor individual installation of the stainless steel hot water storage tank RKHTS200AC and RKHTS260AC next to the HPSU hitemp internal unit.

    For installation of the stainless steel hot water storage tank RKHTS200AC and RKHTS260AC in combination with the HPSU Bi-Bloc.

    RKFMAHT

    RKFMALTA

    14 10 09

    14 10 43

    539,00

    380,00

    Enamel-coated stainless steel hot water storage tankwith a capacity of 300 litres.Height: 1572 mm, diameter: 660 mm, weight: 140 kgincl. integrated 3 kW electrical heating element. Please order hotwater storage tank sensors separately (order number 14 10 37).

    RKHWE300A3V3 14 05 19 1480,00

    Hot water storage tank sensors, LowTempTo measure the water temperature in the storage tank.Needed for storage tank RKHWE300A3V3 for the automaticcontrol at the heat pump device. Cable length: 12 metres.

    SF LT 14 10 37 42,00

    Heat pump

    Hea

    t pum

    p

    33

  • 34

    Heat pumpH

    eat p

    ump

    Technical dataThermal store and solar storage tank, ROTEX HybridCube

    Technical data storage tank for heat pumps for Bi-Bloc, monobloc, HPSU hitemp

    HYC 343 / 19 / 0-P HYC 544 / 19 / 0-P HYC 544 / 32 / 0-P

    14 05 54 14 05 61 14 05 63

    Basic data

    Total storage capacity Litres 300 500 500

    Empty weight kg 64 92 98

    Total filled weight kg 364 592 598

    Dimensions (W x D x H) mm 595 x 615 x 1646 790 x 790 x 1658 790 x 790 x 1658

    Tilt dimension cm 170 167 167

    Max. permissible storage water temperature C 85 85 85

    Heat consumption at readiness and at 60 C kWh /24h 1,3 1,4 1,4

    Drinking water heating

    Drinking water capacity Litres 27,9 29,0 29,0

    Maximum operating pressure bar 6 6 6

    Drinking water heat exchanger material stainless steel stainless steel stainless steel

    Drinking water heat exchanger surface m 5,8 5,8 5,8

    Storage tank charging heat exchanger (stainless steel)

    Water capacity heat exchanger Litres 13,2 9,9 18,5

    Surface of charging heat exchanger m 2,7 2,0 3,8

    Solar heating support (stainless steel)

    Water capacity heat exchanger Litres

    Heat exchanger surface area m

    Thermal output data

    Hot water volume without re-heating with 8 l / min / 12 l / min draw-off rate (TKW = 10 C / TWW = 40 C / TSP = 50 C)

    Litres 184 / 153 324 / 282 (288 / 240)*

    324 / 282 (288 / 240)*

    Hot water volume without re-heating with 8 l / min / 12 l / min draw-off rate (TKW = 10 C / TWW = 40 C / TSP = 60 C)

    Litres 282 / 252 492 / 444 492 / 444

    Hot water volume without re-heating with 8 l / min / 12 l / min draw-off rate (TKW = 10 C / TWW = 40 C / TSP = 65 C)

    Litres 352 / 321 560 / 516 560 / 516

    Re-heating time *Draw off volume 140 l -> 5820 Wh (bath draw off )

    Min. 45(HPSU 008)

    45(HPSU 008)

    25(HPSU 016)

    Re-heating time *Draw off volume 90 l -> 3660 Wh (shower draw off )

    Min. 30(HPSU 008)

    30(HPSU 008)

    17(HPSU 016)

    Pipe connections

    Cold and hot water Inch 1" male thread 1" male thread 1" male thread

    Heating inflow and return flow Inch 1" female thread / 1" male thread

    1" female thread / 1" male thread

    1" female thread / 1" male thread

    Drain-back connection Inch

    Pressure solar connection Inch 3/4 female thread 3/4 female thread 3/4 female thread

  • 35

    Heat pump

    Technical dataThermal store and solar storage tank, ROTEX HybridCube

    * Storage tank only charged with heat pump without immersion heaterReheating time = The time needed to reheat the thermal store to a temperature of 50 C after a certain quantity of DHW has been discharged.

    Suitable solar system ROTEX Solaris from page 110. Storage tank accessories see page 102.

    HYC 343 / 19 / 0-DB HYC 544 / 19 / 0-DB HYC 544 / 32 / 0-DB RKHTS 200 RKHTS 260

    14 05 53 14 05 60 14 05 62 14 05 10 14 05 11

    300 500 500 201 258

    59 87 93 70 78

    359 587 593 271 336

    595 x 615 x 1646 790 x 790 x 1658 790 x 790 x 1658 695 x 600 x 1335 695 x 60 x 1610

    163 167 167 - -

    85 85 85 75 75

    1,3 1,4 1,4 1,2 1,5

    27,9 29,0 29,0 193,5 250,5

    6 6 6 10 10

    stainless steel stainless steel stainless steel

    5,8 6,0 6,0

    13,2 9,9 18,5 7,5 7,5

    2,7 2,0 3,8 1,56 1,56

    2,3 2,3

    0,5 0,5

    184 / 153 364 / 318(328 / 276)*

    364 / 318(328 / 276)*

    255 / 251 330 / 326

    282 / 252 540 / 494 540 / 494 320 / 316 415 / 411

    352 / 321 612 / 564 612 / 564 352 / 348 457 / 453

    45(HPSU 008)

    45(HPSU 008)

    25(HPSU 016)

    30(HPSU hitemp 016)

    40(HPSU hitemp 016)

    30(HPSU 008)

    30(HPSU 008)

    17(HPSU 016)

    1" male thread 1" male thread 1" male thread 3 / 4" female thread 3 / 4" female thread

    1" female thread / 1" male thread

    1" female thread / 1" male thread

    1" female thread / 1" male thread

    3 / 4" female thread 3 / 4" female thread

    1" female thread 1" female thread 1" female thread

    Hea

    t pum

    p

    35

  • 36

    BoilerBo

    iler

    ROTEX A1 oil condensing boiler

    ROTEX A1 oil condensingt Floor-standing oil condensing boilert Power spectrum 12 to 34 kWt Oil blue burner, integrated regulated high-efficiency pump, LAS connection and condensate treatmentt Integrated electronic convenience regulation ROTEX RoCon B1 - Simple and consistent handling for ROTEX A1, GCU compact and HPSU compact - Clear text display with multi-coloured background lighting for visualisation of status and error messages - Intuitive menu guidingt 3FBEZGPSCJPPJM#t 1BUFOUFEBOENVMUJBXBSEXJOOJOH58*/5&$UFDIOPMPHZt ZFBSHVBSBOUFFPOUIFCPJMFSCPEZ

    Our confidence in guaranteeing optimum functionality, particularly in terms of noise emissions from our heat generators, is based on the use of genuine ROTEX flue gas systems. This optimised and adapted to all ROTEX oil condensing boiler and gas condensing boilers.

  • 37

    Boile

    r

    Boiler

    37

  • 38

    Article Type Order No. Price

    A1 BO 15-e 12 to 15 kW A1 BO 15-e 15 49 60 4.199,00

    A1 BO 20-e 12 to 20 kW A1 BO 20-e 15 49 61 4.249,00

    A1 BO 27-e 20 to 27 kW A1 BO 27-e 15 49 62 4.699,00

    A1 BO 34-e 27 to 34 kW A1 BO 34-e 15 49 63 5.349,00

    Attention: Please order the connecting kit A1 (storage tank temperature sensor, connecting fittings, 3-way switch valve), safety group and outdoor sensor separately.

    Additional regulation accessories Type Order No. Price

    Room controllerConvenience regulation with wall housingFor use asa) A remote control (external equipment controller)b) Mixer unit (additional or standalone)c) Room thermostat for heat exchanger.

    RoCon U1 15 70 34 159,00

    Mixer moduleController for mixer valve with speed-controlled high-efficiency pump including mixer circuit flow temperature sensora) in combination with an equipment controller (RoCon B1).Mixer parameters adjustable via the heat generator(up to 16 mixer modules).b) in combination with room controller (RoCon U1)1. can be used as a standalone solution2. can be integrated in the system via BUS.

    RoCon M1 15 70 68 169,00

    Outdoor sensor for RoCon convenience regulation RoCon OT1 15 60 70 29,00

    Storage tank sensor for RoCon DT1 convenience regulation Suitable for all A1 oil condensing boilers. Is only required,if no A1 connection-set is ordered.

    RoCon DT1 15 60 68 29,00

    Accessories for all ROTEX A1 Type Order No. Price

    Boiler support frame 400 mm,With removable casing made of plastic

    KU 15 30 21 289,00

    Safety group for the A1 product rangeWith pressure gauge, 3 bar over-pressure valve, automatic bleeding,MAG connections, filling cock and connector.

    SBG A1 15 60 18 89,00

    Mixer group for all ROTEX heat generators For a mixed heating circuit. Ready to plug in, in the thermal insulation case, with high-efficiency circulation pump, motor mixer, stops valves and temperature displays.

    MK1 15 60 67 799,00

    Mixer group for all ROTEX heat generatorsFor a mixed heating circuit.Ready to plug in, in the thermal insulation case, with PWM-controlled high-efficiency circulation pump, motor mixer, stops valves and temperature displays. (Available from June 2013)

    MK2 15 60 72 799,00

    Fittings kit for mixer group MK1 female thread x 1 1 / 2 flat-sealing.

    VMK1 15 60 53 21,00

    Additive against limescale and corrosion"FERNOX" concentrate cartridge with connecting adapterand hose, pack size 290 ml. Enough for 100 150 l heating water.

    KSK 15 60 50 127,00

    ROTEX A1 oil condensing boiler

    BoilerBo

    iler

  • 39

    Boiler

    Accessories for all ROTEX A1 Type Order No. Price

    Connection Set A1Consisting of storage tank temperature sensor, connection fittings and 3-way switching valve 1" with 230 V motor drive(switching time 6 secs.) for hydraulic connection of a thermal store to the A1 condensing boiler. For installation of the VSA1 it is neccesary to mount the security group SBG A1.

    VSA1 15 48 22 169,00

    Dirt filterFor intercepting dirt in the heater return flow.Input 3/4" female thread, Output 1" female threadup to 28 kWup to 50 kW

    SFR 28SFR 50

    15 60 1115 60 12

    148,35169,95

    Sludge and magnetic separatorCompact sludge separator with drain cock andthermal insulation.Input G1-IG (union nut), outlet G1-lG.

    SAS 1 15 60 21 199,00

    ROTEX A1 oil condensing boiler accessories Type Order No. Price

    Burner-conversion kit for BL15 / BLB20 - Nominal output 12 14 kW (oil nozzle 0.30 / 80H)

    URS12 15 46 15 23,00

    Burner conversion kit for BL27 - Nominal output 20 24 kW (oil nozzle 0.50 / 80H, air nozzle 22)

    URS20 15 46 24 77,50

    Burner conversion kit for BLB34 - Nominal output 25 27 kW (oil nozzle 0.55 / 80H)- Nominal output 33 34 kW (oil nozzle 0.65 / 80H, air nozzle 27)

    URS25URS34

    15 46 2815 46 35

    26,9079,00

    Additional oil connection adaptorPlug in adaptor for connecting up additional plant components,e.g. solenoid valves, temperature monitors, oil feed pump

    ZS 15 40 71 149,00

    Microtec oil filter cartridge, shortMicrotec oil filter cartridge, long

    MC7MC18

    15 60 1315 60 14

    16,0017,00

    Neutralising agent For topping up the NBO condensate treatment

    NKN 15 45 75 35,60

    Service case SKA1 2013 for A1 oilFor all A1 oil condensing boilers from 3/2013

    SKA1 2013 15 41 70 1.279,00

    ROTEX A1 oil condensing boiler

    Type Pack size Order No. Price, each Price / Pack

    VA-Oil feeding linePEX-AL compound pipe as oil supply line approved by the building supervision authorities in the DIBT test. Test mark of the building supervision authority: Z-40.23-331Thick-walled PEX inner pipe with butt-welded aluminium covering and silver-grey PE external layer.Due to the aluminium covering 100 % diffusion tightness. Neutral to heating oil, prevents degradation in the heating oil.Type of delivery: Ring coil packaged in box.

    VA oil pipe, 12 x 3 60 m 17 06 31 2,35 / m 141,25

    Connection screwed fitting VA-OilFor connection the oil feed pipe VA-oil to the extraction armature and to the oil filter.Clamping ring screwed fitting made of brass or parts in contact with oil made of stainless steel.Suitable for VA-Oil pipe 12 x 3, connecting thread 3 / 8 male threadTest mark of the building supervision authority: Z-40.23-331

    Connection screwed fitting VA-Oil VAR1 10 pieces. 17 80 13 10,15 / piece 101,45

    Connect VA-Oil10 m PEX-AL compound pipe as an oil-conveying line with two screwed connection fittings 12 x 3 - 3 / 8 male thread

    10 m 17 06 32 55,00

    Boile

    r

    39

  • 40

    Boiler

    Article Type Order No. Price

    A1 BG 25-e 5 to 25 kW A1 BG 25-e 15 59 35 3.999,00

    A1 BG 25F-e 5 to 25 kW for liquid gas A1 BG 25-e 15 59 36 4.099,00

    A1 BG 40-e 8 to 40 kW A1 BG 40-e 15 59 42 4.999,00

    A1 BG 40F-e 8 to 40 kW for liquid gas A1 BG 40-e 15 59 43 5.099,00

    Attention: Please order the connecting kit A1 (storage tank temperature sensor, connecting fittings, 3-way switch valve) separately. See page 38. Accessories page 38, 39.

    ROTEX A1 gas condensing boiler

    ROTEX A1 gas condensing boilert Floor-standing gas condensing boilert Power spectrum 5 to 40 kWt Modulating burner operationt Gas surface burner, integrated regulated high-efficiency pump, LAS connectiont Integrated electronic convenience regulation ROTEX RoCon B1 - Simple and consistent handling for ROTEX A1, GCU compact and HPSU compact - Clear text display with multi-coloured background lighting for visualisation

    of status and error messages - Intuitive menu guiding- Patented and multi-award winning TWINTEC technology- 15 year guarantee on the boiler body

    Our confidence in guaranteeing optimum functionality, particularly in terms of noise emissions from our heat generators, is based on the use of genuine ROTEX flue gas systems. This is optimised and adapted to all ROTEX oil condensing and gas condensing boilers.

    Boile

    r

  • 41

    Boiler

    Condensing boiler with low-toxin oil blue burner or modulating gas surface burner, regulation RoCon B1, high-efficiency pump and LAS connection for room-air independent operation.

    Oil condensing boiler Gas condensing boilers

    A1 BO 15-e A1 BO 20-e A1 BO 27-e A1 BO 34-e A1 BG 25-e A1 BG 40-e

    modulating

    Nominal output according to DIN-EN 303 kW 15 20 24 34 5 25 8 40

    Ready for bio-oil Fully equippedFully

    equippedFully

    equippedFully

    equipped

    Factory setting kW / %* 15 18 25 30 30 80 * 30 80 *

    Setting range in standard equipment 1) kW / %* 15 15 20 24 27 27 32 20 100 * 20 100 *

    Permissible operating excess pressure bar 4 4 4 4 4 4

    Max. permissible feed temperature C 80 80 80 80 80 80

    Max. boiler efficiency % 105 105 105 105 109 109

    Circulation pump high-efficiency, regulated - ErP-ready (EEI < 0.23)3)

    Flue gas temperature C 35 75 35 85 38 89 40 98 32 60 34 82

    Weight of the boiler body kg 49 49 58 67 49 67

    Total weight Unit2) kg 81 81 96 113 77 107

    Length cm 72 72 72 72 72 72

    Width cm 62,5 62,5 62,5 62,5 62,5 62,5

    Height cm 110 110 122 134 110 134

    Minimum height of the installation room cm 134 134 147 159 134 159

    Water content Litres 3 3 4,5 5 3 5

    Flue gas / supply air connection diameter mm 80 / 125 80/125 80 / 125 80 / 125 80 / 125 80 / 125

    Order No. 15 49 60 15 49 61 15 49 62 15 49 63 15 59 35 15 59 42

    Control RoCon B1 RoCon B1 RoCon B1 RoCon B1 RoCon B1 RoCon B1

    *Can be parametrised via RoCon controller1) For smaller or greater outputs of the A1 condensing boiler you will need conversion kits - see accessories.2) Transport weight with the lining and condensate treatment unit removed.3) From 2015, the European ErP Guidelines will only permit the use of pumps with an energy efficiency index < 0.23 in boilers. From 2020, these requirements will also apply to spare parts. All the ROTEX condensing boilers A1 and GCU are already fitted with pumps that will be permitted up to and beyond 2020.

    Flue gas systems from page 52

    Technical dataROTEX A1 oil/gas condensing boilers

    Boile

    r

    41

  • 42

    Boile

    rBoiler

    Gas condensing/solar combination, ROTEX GCU compact

    ROTEX GCU compactt Floor-standing gas condensing boiler with integrated hot water or solar storage tankt Power spectrum 5 to 33 kWt Storage tank volume 300 or 500 litrest Solar option (Drain-Back)t Gas-adaptive combustion system SCOT with fully-electronic gas-air compoundt Unit ready to plug in with regulated high-efficiency pump, 3-way switch valve and LAS connectiont Integrated electronic convenience regulation ROTEX RoCon B1 - Simple and consistent handling for ROTEX A1, GCU compact and HPSU compact - Clear text display with multi-coloured background lighting for visualisation of status and error messages - Intuitive menu guidingAdditional features for Version Biv:t #JWBMFODZPQUJPOGPSJOUFHSBUJPOPGBOBEEJUJPOBMIFBUTPVSDFPSBQSFTTVSJTFETPMBSTZTUFN#JW

    Our confidence in guaranteeing optimum functionality, particularly in terms of noise emissions from our heat generators, is based on the use of genuine ROTEX flue gas systems. This optimised and adapted to all ROTEX oil condensing boiler and gas condensing boilers.

  • 43

    Boile

    r

    Boiler

    Article Type Order No. Price

    GCU compact BivOutput-modulating from 5 15 kW for natural and liquid gas, storage tank volume 300 litres, additional pressurised heat exchanger for solar applications or external heat generator.

    GCU compact 315 Biv 15 74 02 3.709,00

    GCU compact BivOutput-modulating from 5 24 kW for natural and liquid gas, storage tank volume 300 litres, additional pressurised heat exchanger for solar applications or external heat generator.

    GCU compact 324 Biv 15 74 08 3.869,00

    GCU compact BivOutput-modulating from 5 15 kW for natural and liquid gas, storage tank volume 500 litres, additional pressurised heat exchanger for solar applications or external heat generator.

    GCU compact 515 Biv 15 74 04 4.339,00

    GCU compact BivOutput-modulating from 5 24 kW for natural and liquid gas, storage tank volume 500 litres, additional pressurised heat exchanger for solar applications or external heat generator.

    GCU compact 524 Biv 15 74 06 4.499,00

    GCU compact BivOutput-modulating from 5 33 kW for natural and liquid gas, storage tank volume 500 litres, additional pressurised heat exchanger for solar applications or external heat generator.

    GCU compact 533 Biv 15 74 07 4.659,00

    GCU compactOutput-modulating from 5 15 kW, storage tank volume 300 litres for natural and liquid gas

    GCU compact 315 15 74 01 3.299,00

    GCU compactOutput-modulating from 5 24 kW, storage tank volume 300 litres for natural and liquid gas

    GCU compact 324 15 74 09 3.459,00

    GCU compactOutput-modulating from 5 15 kW, storage tank volume 500 litres for natural and liquid gas

    GCU compact 515 15 74 03 3.929,00

    GCU compactOutput-modulating from 5 24 kW, storage tank volume 500 litres for natural and liquid gas

    GCU compact 524 15 74 10 4.089,00

    GCU compactOutput-modulating from 5 33 kW, storage tank volume 500 litres for natural and liquid gas

    GCU compact 533 15 74 05 4.249,00

    Regulation accessories Type Order No. Price

    Room controllerConvenience regulation with wall housingFor use asa) A remote control (external equipment controller)b) Mixer operating unit (additional or standalone)c) Room thermostat for heat exchanger.

    RoCon U1 15 70 34 159,00

    Mixer moduleController for mixer valve with speed-controlled high-efficiency pump including mixer circuit sensora) in combination with an equipment controller (RoCon B1).Mixer parameters adjustable via the heat generator.b) in combination with room controller (RoCon U1)1. can be used as a standalone solution2. can be integrated in the system via BUS.

    RoCon M1 15 70 68 169,00

    Outdoor sensor for RoCon convenience regulation RoCon OT1 15 60 70 29,00

    Tip: GCU compact available from June 2013.

    Gas condensing/solar combination, ROTEX GCU compact

    43

  • 44

    BoilerBo

    iler

    Accessories Type Order No. Price

    Flue-gas kit GCU compactDouble-walled connection set of 2x45 elbows with connection extenderfrom DN60 / 100 to DN80 / 125.

    AAS1 GCU c 15 50 79.17 169,00

    Mixer group for all ROTEX heat generators For a mixed heating circuit. Ready to plug in, in the thermal insulation case, with high-efficiency circulation pump, motor mixer, stops valves and temperature displays.

    MK1 15 60 67 799,00

    Mixer group for all ROTEX heat generatorsFor a mixed heating circuit.Ready to plug in, in the thermal insulation case, with PWM-controlled high-efficiency circulation pump, motor mixer, stops valves and temperature displays. (Available from June 2013)

    MK2 15 60 72 799,00

    Fittings kit for mixer group MK1 female thread x 1 1 / 2 flat-sealing.

    VMK1 15 60 53 21,00

    Safety module for the GCU compactProduct rangeWith pressure gauge, 3 bar over-pressure valve, automatic bleeder, MAG connection and filling cock.

    SBG GCU compact 15 70 46 89,00

    Sludge and magnetic separatorCompact sludge separator with drain cock and thermal insulation. Input G1-IG (union nut), outlet G1-lG.

    SAS1 15 60 21 199,00

    Service case for GCU compact(from year of manufacture 06 / 2013)

    SKGCUc1 15 41 72 929,00

    Gas condensing/solar combination, ROTEX GCU compact

  • 45

    Boiler

    Boile

    r

    45

  • 46

    BoilerBo

    iler

    Technical data GCU compact GCU compact 315 Biv

    GCU compact 324 Biv

    GCU compact 515 Biv

    GCU compact 524 Biv

    GCU compact 533 Biv

    Basic data 15 74 02 15 74 08 15 74 04 15 74 06 15 74 07

    Total storage capacity Litres 300 300 500 500 500

    Empty weight kg 86 86 124 124 124

    Total filled weight kg 386 386 624 624 624

    Dimensions (W x D x H) mm 595 x 615 x 1945 595 x 615 x 1945 790 x 790 x 1951 790 x 790 x 1951 790 x 790 x 1951

    Max. permissible storage water temperature C 85 85 85 85 85

    Stand-by heating power kWh / 24h 1,7 1,7 1,8 1,8 1,8

    Control RoCon RoCon RoCon RoCon RoCon

    Circulation pump high-efficiency, regulated - ErP ready (EEI < 0.23)3)

    Drinking water heating

    Drinking water capacity Litres 19 19 24,5 24,5 24,5

    Maximum operating pressure bar 6 6 6 6 6

    Material domestic water heat exchanger stainless steel stainless steel stainless steel stainless steel stainless steel

    Drinking water heat exchanger surface m 4 4 5 5 5

    Storage tank charging / discharging heat exchanger (stainless steel)

    Water capacity heat exchanger Litres 9,4 9,4 10,5 10,5 19,3

    Surface of charging heat exchanger m 1,9 1,9 2,1 2,1 4

    Pressurised solar heat exchanger (stainless steel)

    Water capacity heat exchanger Litres 4,2 4,2 12,5 12,5 12,5

    Surface of charging heat exchanger m 0,8 0,8 1,7 1,7 1,7

    Thermal output data

    NL efficiency characteristic acc. to DIN 47081) 2 2,1 2,1 2,1 2,2

    D value (specific water flow) acc. to EN625 2) l / min 22 24 23 25 27

    Continuous output in accordance with DIN4708 Qn

    kW 15 24 15 24 33

    Max. draw-off rate for a period of 10 min at(TKW = 10 C / TWW = 40 C / TSP = 60 C)

    l / min 19 21 20 23 24

    Hot water volume without reheating at 15 l / min draw-off rate (TKW = 10 C / TWW = 40 C / TSP = 60 C)

    Litres 200 200 230 230 230

    Hot water volume with reheating at 15 l / min with draw-off rate (TKW = 10 C / TWW = 40 C / TSP = 60 C)

    Litres 300 400 370 600 1300

    Short-term water quantity in 10min Litres 190 210 200 230 240

    Heat generator characteristic data

    Nominal output kW 5 15 5 24 5 15 5 24 5 33

    Rated thermal load kW 5,5 16 5,5 25 5,5 16 5,5 25 5,5 34

    Device type B23 / B23P / B33 / B53 / B53P / C13x / C33x / C43x / C53x / C63x / C83xElectrical data V / Hz 230 / 50 230 / 50 230 / 50 230 / 50 230 / 50

    Protection type IP 20 20 20 20 20

    Maximum permissible operating pressure bar 3 3 3 3 3

    Maximum permitted operating temperature C 85 85 85 85 85

    Maximum boiler efficiency % 110 110 110 110 110

    Flue gas / air infeed connection diameter mm DN 60 / 100 (with connection kit No. 155079.17 DN 80 / 125)

    Pipe connections

    Cold and hot water Inch 1" male thread 1" male thread 1" male thread 1" male thread 1" male thread

    Heating inflow and return flow Inch 1" female thread 1" female thread 1" female thread 1" female thread 1" female thread

    Technical data GCU compact

  • 47

    1) At nominal output, 80 C feed temperature, 65 C storage tank temperature, 45 C hot water temperature and 10 C cold water temperature

    2) Explanation: The specific water flow to EN 625 is the flow of drinking water at an average temperature increase of 30 K that the GCU compact can supply during two consecutive draw-offs of 10 minutes each, starting from a charging temperature of 65 C. The standard calls for a delay between the draw-offs of 20 minutes. The GCU compact achieves this value even at shorter delay periods.

    3) From 2015, the European ErP Guidelines will only permit the use of pumps with an energy efficiency index < 0.23 in boilers. From 2020, these requirements will also apply to spare parts. AllROTEX condensing boilers A1 and GCU compact are already equipped with pumps that will be permitted up to and beyond 2020.

    GCU compact315

    GCU compact324

    GCU compact515

    GCU compact524

    GCU compact533

    15 74 01 15 74 09 15 74 03 15 74 10 15 74 05

    300 300 500 500 500

    86 86 124 124 124

    386 386 624 624 624

    595 x 615 x 1945 595 x 615 x 1945 790 x 790 x 1951 790 x 790 x 1951 790 x 790 x 1951

    85 85 85 85 85

    1,7 1,7 1,8 1,8 1,8

    RoCon RoCon RoCon RoCon RoCon

    high-efficiency, regulated - ErP ready (EEI < 0.23)3)

    19 19 24,5 24,5 24,5

    6 6 6 6 6

    stainless steel stainless steel stainless steel stainless steel stainless steel

    4 4 5 5 5

    9,4 9,4 10,5 10,5 19,3

    1,9 1,9 2,1 2,1 4

    - - - - -

    - - - - -

    2 2,1 2,1 2,1 2,2

    22 24 23 25 27

    15 24 15 24 33

    19 21 20 23 24

    200 200 230 230 230

    300 400 370 600 1300

    190 210 200 230 240

    5 15 5 24 5 15 5 24 5 33

    5,5 16 5,5 25 5,5 16 5,5 25 5,5 34

    B23 / B23P / B33 / B53 / B53P / C13x / C33x / C43x / C53x / C63x / C83x230 / 50 230 / 50 230 / 50 230 / 50 230 / 50

    20 20 20 20 20

    3 3 3 3 3

    85 85 85 85 85

    110 110 110 110 110

    DN 60 / 100 (with connection kit No. 155079.17 DN 80 / 125)

    1" male thread 1" male thread 1" male thread 1" male thread 1" male thread

    1" female thread 1" female thread 1" female thread 1" female thread 1" female thread

    Boiler

    Boile

    r

    Technical data GCU compact

    47

  • 48

    Gas condensing wall-mounted boiler ROTEX GW

    Boiler

    Article Type Order No. Price

    ROTEX GWVersion CWall-mounted gas condensing unit compact unit with integrated hygienic hot water generation in the instantaneous through-flow principle

    4,5 21.6 kW (80 / 60 C), 3-step pump 5,2 24.2 kW (50 / 30 C), 3-step pump

    5,8 26.2 kW (80 / 60 C), 3-step pump 6.6 29.1 kW (50 / 30 C), 3-step pump

    8,5 36.5 kW (80 / 60 C), high efficiency pump9,6 40.0 kW (50 / 30 C), high efficiency pump

    GW 22C

    GW 26C

    GW 37C

    15 00 28

    15 00 29

    15 00 30

    2.359,00

    2.449,00

    2.569,00

    Article Type Order No. Price

    ROTEX GWVersion TWall-mounted gas condesning compact unit with integrated 3-way valve for storage tank charging

    4,5 21.6 kW (80 / 60 C), 3-step pump5,2 24.2 kW (50 / 30 C), 3-step pump

    5,8 26.2 kW (80 / 60 C), 3-step pump6,6 29.1 kW (50 / 30 C), 3-step pump

    8,5 36.5 kW (80 / 60 C), high efficiency pump9,6 40.0 kW (50 / 30 C), high efficiency pump

    GW 22T

    GW 26T