8
CASH VALVE B SERIES PRESSURE REGULATORS CAVMC-0509-US-1212 Copyright © 2012 Pentair WWW.PENTAIR.COM/VALVES Series B regulators are designed and built to withstand long periods of service without maintenance. Features • Sizes: Available in 1 /4", 3 /8", 1 /2", 3 /4", 1", 1 1 /4", 1 1 /2" and 2" sizes with either iron or bronze bodies with female threaded connections. Simplicity of Design: The rugged but simple design incorporated in all versions of the Type B regulator lends itself to easy maintenance and repair. Disassembly is simple since there are only six rustproof bolts to remove when replacing diaphragms or pressure springs. The inner valve assembly is easy to clean or replace by just loosening the large hex head bottom plug. All major repairs can normally be made without removing the valve from the line. Optional Cryogenic Service: Approved construction is offered for the Type B regulator to enable it to be used in handling cold fluids or gases. For more information write for Data Sheet CAVMC-0514. Inbuilt Strainer Screen: The working parts of the valve are protected by a self-supporting inbuilt Monel ® strainer screen which is easily removed for cleaning by removing the bottom plug. Time Tested Rugged Construction: The Type B regulator has proven itself in countless applications for well over 40 years. The heavy rugged construction ensures long life and service; bodies are of iron or bronze. The large area reinforced BUNA-N diaphragm is furnished as standard for water or air. These valves are fitted with a carefully matched brass piston and cylinder with a composition seat disc insert for tight shut-off. Easy Pressure Adjustment: Pressure adjustment can be changed easily by loosening the lock nut and simply turning the adjusting screw – clockwise to increase, and counterclockwise to decrease the delivery pressure. The Type B regulator is furnished with a square head adjusting screw and hex lock nut as standard. They may also be fitted with either a T-handle or an aluminum handwheel for an additional charge. Note: If downstream pressure control is critical to the safety of the installation, then the downstream side should be protected by a safety relief valve set to relieve at the maximum safe limit, but at least 10 psi higher than the delivery setting of the pressure regulator. Description The Cash Valve Series B pressure reducing and regulating valves are single seated, spring loaded, direct acting diaphragm- type valves that automatically reduce a high initial inlet pressure to a lower delivery pressure and maintain that lower pressure within reasonably close limits. Exceptionally dependable, Series B regulators are an excellent example of sound engineering and design. They are made of high quality materials to meet the requirements of a variety of applications. Each valve is assembled by skilled workmen and tested before shipment. Series B regulators are designed and built to withstand long periods of service without maintenance. However, a functioning or operating piece of equipment such as an automatic valve does, in time, require attention. Simplicity of design aids in the ease of maintenance when repairs may be needed. To keep these regulators in top operating order, Cash Valve make available for the more popular valve models, a convenient, pre-packaged repair kit specifically designed for that particular valve. Each kit includes genuine Cash Valve replacement parts for those that are subject to wear or damage through normal regulator usage. Every regulator is supplied with the desired delivery pressure pre-set by the factory. Cash Valve Series B regulators are designed to meet the installation requirements of a variety of systems and are designated as follows: Type B – Water and Air Service (Up to 180°F) Type B – Steam Service (Up to 400°F)

CASH VALVE B SERIES PRESSURE REGULATORS - … - B Series - TEMPRESCO.pdf · CASH VALVE B SERIES PRESSURE REGULATORS Copyright © 2012 Pentair CAVMC-0509-US-1212 page 3 Optional Differential

  • Upload
    vantruc

  • View
    230

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CASH VALVE B SERIES PRESSURE REGULATORS - … - B Series - TEMPRESCO.pdf · CASH VALVE B SERIES PRESSURE REGULATORS Copyright © 2012 Pentair CAVMC-0509-US-1212 page 3 Optional Differential

CASH VALVE B SERIESPRESSURE REGULATORS

CAVMC-0509-US-1212 Copyright © 2012 Pentair WWW.PENTAIR.COM/VALVES

Series B regulators are designed and built to withstand long periods of service without maintenance.

Features• Sizes: Available in 1/4", 3/8", 1/2", 3/4", 1",11/4", 11/2" and 2" sizes with either ironor bronze bodies with female threadedconnections.

• Simplicity of Design: The rugged butsimple design incorporated in allversions of the Type B regulator lendsitself to easy maintenance and repair.Disassembly is simple since there areonly six rustproof bolts to remove whenreplacing diaphragms or pressuresprings. The inner valve assembly iseasy to clean or replace by justloosening the large hex head bottomplug. All major repairs can normally be made without removing the valvefrom the line.

• Optional Cryogenic Service: Approvedconstruction is offered for the Type Bregulator to enable it to be used in

handling cold fluids or gases. For more information write for Data SheetCAVMC-0514.

• Inbuilt Strainer Screen: The workingparts of the valve are protected by aself-supporting inbuilt Monel® strainerscreen which is easily removed forcleaning by removing the bottom plug.

• Time Tested Rugged Construction:The Type B regulator has proven itself in countless applications for well over 40 years. The heavy ruggedconstruction ensures long life andservice; bodies are of iron or bronze.The large area reinforced BUNA-Ndiaphragm is furnished as standard forwater or air. These valves are fitted witha carefully matched brass piston andcylinder with a composition seat discinsert for tight shut-off.

• Easy Pressure Adjustment: Pressureadjustment can be changed easily byloosening the lock nut and simplyturning the adjusting screw – clockwiseto increase, and counterclockwise todecrease the delivery pressure. TheType B regulator is furnished with asquare head adjusting screw and hexlock nut as standard. They may also be fitted with either a T-handle or analuminum handwheel for an additionalcharge.

Note: If downstream pressure control iscritical to the safety of the installation,then the downstream side should beprotected by a safety relief valve set torelieve at the maximum safe limit, butat least 10 psi higher than the deliverysetting of the pressure regulator.

DescriptionThe Cash Valve Series B pressure reducingand regulating valves are single seated,spring loaded, direct acting diaphragm-type valves that automatically reduce ahigh initial inlet pressure to a lowerdelivery pressure and maintain that lowerpressure within reasonably close limits.

Exceptionally dependable, Series Bregulators are an excellent example of sound engineering and design. They aremade of high quality materials to meet therequirements of a variety of applications.Each valve is assembled by skilledworkmen and tested before shipment.

Series B regulators are designed and built to withstand long periods of servicewithout maintenance. However, afunctioning or operating piece ofequipment such as an automatic valvedoes, in time, require attention. Simplicityof design aids in the ease of maintenance

when repairs may be needed. To keepthese regulators in top operating order,Cash Valve make available for the morepopular valve models, a convenient, pre-packaged repair kit specificallydesigned for that particular valve. Each kitincludes genuine Cash Valve replacementparts for those that are subject to wear ordamage through normal regulator usage.

Every regulator is supplied with thedesired delivery pressure pre-set by the factory.

Cash Valve Series B regulators aredesigned to meet the installationrequirements of a variety of systems and are designated as follows:

• Type B – Water and Air Service (Up to 180°F)

• Type B – Steam Service (Up to 400°F)

Page 2: CASH VALVE B SERIES PRESSURE REGULATORS - … - B Series - TEMPRESCO.pdf · CASH VALVE B SERIES PRESSURE REGULATORS Copyright © 2012 Pentair CAVMC-0509-US-1212 page 3 Optional Differential

CASH VALVE B SERIESPRESSURE REGULATORS

page 2 CAVMC-0509-US-1212 Copyright © 2012 Pentair

Series B regulators are available in 1/4" through 2" sizes with either iron orbronze bodies and feature a variety ofoptional internal trim (diaphragm, pistonand cylinder) that enable them to be usedin a wide range of applications.

Each Series B regulator is equipped with a pressure spring selected to providethe desired outlet or reduced deliverypressure setting. Depending on theadjusting spring installed, deliverypressures may be adjusted from aminimum of 2 psi to a maximum of 150 psi. The range of adjustment orsatisfactory working range of the individualsprings that may be fitted to each valvesize are listed in the Spring Range Tableshown under Specifications, Page 4.

Type B Water and Air regulators aresuitable for use on paint spray equipment,dishwashers, air tanks and equipment,food, chemical, and industrial processlines, and hundreds of other applications.

The Type B Water and Air regulator isdesigned for systems having a maximumoperating temperature of 180°F. The tablebelow shows the standard factory trim andinlet pressure maximums for valves fittedwith iron or bronze bodies. Type B Waterand Air regulators are normally furnishedas indicated in the table, however, anycombination of body material, piston-cylinder and diaphragm is available onspecial order.

B Water and Air Service (up to 180°F)

Application

B Steam Service (up to 400°F)

ApplicationType B Steam pressure reducing andregulating valve is ideally suited forinstallation in pressing irons, steamcookers, degreasers, sterilizers,vulcanizers, and hundreds of otherapplications. These valves are designed forsteam operating temperatures up to 400°Fand are available in 1/4" to 2" sizes witheither iron body or bronze bodies: iron

body valves are for systems having initialpressures up to 150 psi. Bronze bodies arefor initial pressures up to 250 psi.

The table below shows standard factorytrim and inlet pressure maximums forType B Steam regulators. Valves willnormally be furnished as indicated,however, other combinations of body

material, piston-cylinder and diaphragmare available on special order. Iron body B valves furnished with Teflon® seat.

Type B Steam regulators can also befurnished with a differential pressurecontrol feature which may be desirable in steam/oil atomizing service. Refer toFeatures section.

Water or Air

Service

Maxim

umInitial Pressure

(psig

)

Maxim

umReduced P

ressure

(psig

)

Iron

Bronze

Bronze

BUNA

-N

BUNA

-N

BodyMaterial

Piston andCylinder

Seat DiscMaterial

DiaphragmStock

Max. Oper.Temp. °F

400200 125

150 X XX

XX

XX

180180X

ServiceSaturatedSteam

Maximum

Initial Pressure

(psig)

Maximum

Reduced Pressure

(psig)

Iron

Bronze

Bronze

Teflo

Phosphor

Bronze

BodyMaterial

Piston andCylinder

Teflon®Seat Disc*

DiaphragmStock

250150 125

150 X X XX X

XXX

Max. Oper.Temp. °F

400400

Type B Pressure Regulator/Water and Air

Page 3: CASH VALVE B SERIES PRESSURE REGULATORS - … - B Series - TEMPRESCO.pdf · CASH VALVE B SERIES PRESSURE REGULATORS Copyright © 2012 Pentair CAVMC-0509-US-1212 page 3 Optional Differential

CASH VALVE B SERIESPRESSURE REGULATORS

Copyright © 2012 Pentair CAVMC-0509-US-1212 page 3

Optional Differential Pressure Control(Type B Steam regulators only):The Type B Steam regulator can be factory modified to serve as a constantdifferential pressure control valve byincorporating a 1/4" side tap in the springhousing. In a typical steam-oil atomizinginstallation sketch below, fluid loadingpressure is introduced above thediaphragm of the Type B regulator and

steam is delivered through the valve at a regulated pressure higher than theloading pressure, with the difference inpressure being determined by thediaphragm spring setting. The outletsteam pressure is automaticallymaintained to provide a constant, fixedpressure differential between the steampressure and the oil pressure. Variations inthe loading pressure are reflected in a

pound-for-pound change in the dischargepressure.

Valves equipped with the optionaldifferential pressure control are fitted witha pressure-tight closing cap and gasketover the pressure adjusting screw. Inaddition, a gasket is installed above thediaphragm to ensure a good seal betweenthe spring housing and the valve body.

B Steam Service (up to 400°F)

StandardAdjusting Screw

T-Handle

Pump

Oil ControlValve

OilBurner

BoilerSteam

Cash ValveType B

From Oil Tank

DifferentialLine

Type B Steam WithDifferential

Construction Interior

Options

Typical Steam-Oil Atomizing Installation

*For pressure loaded valves only**For use with metal diaphragms only

Materials of Construction Part DescriptionAdjusting Screw Cap*Cap Gasket*BodySpring ChamberAdjusting SpringPressure PlateDiaphragmDiaphragm Gasket**Pusher Post Button

BrassFiberIron or BronzeIron or BronzeSteelCast Iron or BronzeBUNA-N, BronzeAramid FiberBrass

Materials

CylinderPistonPusher PostSeat DiscPiston SpringStrainer ScreenBottom GasketBottom Plug

BrassBrassBrassBUNA-N or Teflon®

302 Stainless SteelMonel®

Copper/FiberBrass

Size Spring Ranges (in psi)1/4"3/8"1/2"3/4"1"11/4"11/2"2"

2-252-30

2-202-30

2-202-152-152-20

20-6020-7010-5010-3510-4510-3010-3010-60

30-10040-11030-12530-7520-6020-5020-5020-100

50-15090-15050-15050-11055-10045-10045-10090-150

105-15090-15090-15090-150

Type BValve Size A B C Iron Bronze

Dimensions Shipping Weight (lbs.)

1/4"3/8"1/2"3/4"1"11/4"11/2"2"

3"37/8"41/2"51/8"57/8"63/4"63/4"91/4"

27/8"41/2"41/2"45/8"53/8"61/8"61/8"81/2"

13/4"13/4"21/8"21/8"21/8"25/8"25/8"31/2"

23/451/281016202037

571/2912181832

3

Specifications

B

C

A

Page 4: CASH VALVE B SERIES PRESSURE REGULATORS - … - B Series - TEMPRESCO.pdf · CASH VALVE B SERIES PRESSURE REGULATORS Copyright © 2012 Pentair CAVMC-0509-US-1212 page 3 Optional Differential

CASH VALVE B SERIESPRESSURE REGULATORS

page 4 CAVMC-0509-US-1212 Copyright © 2012 Pentair

Gallons Per Minute By SizeInlet Pressure(psig)

OutletPressure(psig) 1/4" 3/8" 1/2" 3/4" 1" 11/4" 11/2" 2"151040251065502510907550251007550251401007550251501007550251501007550251501007550

.6

.6

.8

.8

.81.01.11.31.31.51.61.71.81.51.72.02.01.51.92.02.22.21.92.22.52.72.72.12.52.82.92.92.53.54.24.2

1.01.21.41.61.62.02.12.32.32.73.03.23.42.93.33.63.62.93.53.84.04.03.54.04.64.94.93.94.65.25.55.54.66.57.87.8

2.62.93.53.83.84.85.15.85.86.77.48.08.37.08.09.09.07.08.69.39.99.98.69.911.212.212.29.611.212.813.413.411.216.019.219.2

4.04.55.56.06.07.58.09.09.010.511.512.513.011.012.514.014.011.013.514.515.515.513.515.517.519.019.015.017.520.021.021.017.525.030.030.0

5.76.47.98.68.610.711.412.912.915.016.417.918.615.717.920.020.015.719.320.722.222.219.322.225.027.227.221.525.028.630.030.025.035.842.942.9

9.210.412.713.813.817.318.420.720.724.226.528.829.925.328.832.232.225.327.033.435.735.731.135.740.343.743.734.540.346.048.348.340.357.569.069.0

10.411.714.315.615.619.520.423.423.427.329.932.533.828.632.536.436.428.635.137.740.340.335.140.345.549.449.439.045.552.054.654.645.565.078.078.0

16.018.022.024.024.030.032.036.036.042.046.050.052.044.050.056.056.044.054.058.062.062.054.062.070.076.076.060.070.080.084.084.070.0100.0120.0120.0

25

50

75

100

125

150

200

250

300/400

Note: Capacities are based upon a 20% fallout.

The amount of air or fluid any regulatorwill pass is governed by two factors; (1)pressure differential, or the differencebetween the inlet and outlet pressure,and (2) a characteristic known as fall-offor droop, by which the outlet pressuredrops slightly as flow starts through the

valve and drops off even more asincreased demand requires increasedflow. The rates of flow stated on thefollowing charts are based on assumedconditions, which may be consideredaverage for a given installation.

Specifications (Continued)

B Series Water Capacity Information

Page 5: CASH VALVE B SERIES PRESSURE REGULATORS - … - B Series - TEMPRESCO.pdf · CASH VALVE B SERIES PRESSURE REGULATORS Copyright © 2012 Pentair CAVMC-0509-US-1212 page 3 Optional Differential

CASH VALVE B SERIESPRESSURE REGULATORS

Copyright © 2012 Pentair CAVMC-0509-US-1212 page 5

Note: Capacities are based upon a 20% fallout.

B Series Air Capacity InformationAir Capacity in SCFM By SizeInlet

Pressure(psig)

OutletPressure(psig) 1/4" 3/8" 1/2" 3/4" 1" 11/4" 11/2" 2"151040251065502510907550251007550251401007550251501007550251501007550251501007550

4.75.07.08.28.27.58.511.011.09.012.015.015.013.015.018.018.015.018.023.025.025.019.023.027.029.029.025.033.037.037.037.034.037.043.043.0

7.07.510.512.312.311.312.816.516.513.518.022.522.519.522.527.027.022.527.034.537.537.528.534.540.543.543.537.549.555.555.555.551.055.564.564.5

16.517.524.528.728.726.329.838.538.531.542.052.552.545.552.563.063.052.563.080.587.587.566.580.594.5101.5101.587.5115.5129.5129.5129.5115.0129.5150.5150.5

23.525.035.041.041.037.542.555.055.045.060.075.075.065.075.090.090.075.090.0115.0125.0125.095.0115.0135.0145.0145.0125.0165.0185.0185.0185.0170185215215

37.640.056.065.665.660.068.088.088.072.096.0120.0120.0104.0120.0144.0144.0120.0144.0184.0200.0200.0152.0184.0216.0232.0232.0200.0264.0296.0296.0296.0272.0296.0344.0344.0

56.460.084.098.498.490.0102.0132.0132.0108.0144.0180.0180.0156.0180.0216.0216.0180.0216.0276.0300.0300.0228.0276.0324.0348.0348.0300.0396.0444.0444.0444.0408.0444.0516.0516.0

65.870.098.0114.8114.8105.0115.0154.0154.0126.0168.0210.0210.0182.0236.0252.0252.0210.0252.0322.0350.0350.0266.0322.0378.0406.0406.0350.0462.0518.0518.0518.0476.0518.0602.0602.0

105.8112.5157.5184.5184.5168.8191.3247.5247.5203.0270.0337.5337.5293.0338.0405.0405.0338.0405.0518.0563.0563.0428.0518.0608.0653.0653.0563.0743.0833.0833.0833.0765.0833.0968.0968.0

25

50

75

100

125

150

200

250

300/400

Specifications (Continued)

Page 6: CASH VALVE B SERIES PRESSURE REGULATORS - … - B Series - TEMPRESCO.pdf · CASH VALVE B SERIES PRESSURE REGULATORS Copyright © 2012 Pentair CAVMC-0509-US-1212 page 3 Optional Differential

CASH VALVE B SERIESPRESSURE REGULATORS

page 6 CAVMC-0509-US-1212 Copyright © 2012 Pentair

B Series Steam Capacity Information (with Teflon® Seat)Steam LBS Per Hour By SizeInlet

Pressure(psig)

OutletPressure(psig) 1/4" 3/8" 1/2" 3/4" 1" 11/4" 11/2" 2"1510402510655025109075502510075502514012510075501501251007515012510075150125100

252536424239536869498485858811111511563112116137137130153179179190214230230196253253

383855636359781021029112612912913316517217295168174204204195230267267287322344344294379379

8888129137137139185239239154294300300266385400400126392405479479454535626626671750804804686888888

12612618321021019726334234223142042742744155057357321056057868368364876389389395610721147114798012671267

2022022943363363164215465463716726836837068819169163508969241093109310371221142914291532171518351835156820272027

3023024405045044736318208205601008102510251008132013751375525134413871639163915551831214321432297257227522752235230393039

3533535145885885537369569566541176119611961165154016031603616156816181912191218142136250025002681300232123212274435463546

56756782694594588911841537153710501890192219221985247725772577994252026033074307429163434401940194308482351625162441056995699

25

50

75

100

125

150

200

225

250

Specifications (Continued)

*To determine capacity when valves have metal-to-metal seats use a multiplier of 0.6.Note: Capacities are based upon a 20% fallout.

Page 7: CASH VALVE B SERIES PRESSURE REGULATORS - … - B Series - TEMPRESCO.pdf · CASH VALVE B SERIES PRESSURE REGULATORS Copyright © 2012 Pentair CAVMC-0509-US-1212 page 3 Optional Differential

CASH VALVE B SERIESPRESSURE REGULATORS

Copyright © 2012 Pentair CAVMC-0509-US-1212 page 7

DescriptionThe Type B-95 is a fully automaticpressure reducing valve designed toreduce a high inlet pressure to a lowerpressure and maintain the lower pressureto reasonably close limits. Also availablein a cryogenic version, it is ideal for use in the pressure build-up circuit, for eitherliquid or gas service.

Specification DataService: Air, water, steam, oil and otherliquids, also cryogenic liquids and gases.

Sizes: 1/2", 3/4" and 1"

Connections: Threaded (NPTF)

Temperature Rating: +450°F to -320°F depending on construction.

Maximum Inlet Pressure:720 psig @ +180°F 400 psig @ -320°F to +450°F

MaterialsAvailable in carbon steel and stainlesssteel.Diaphragms — BUNA-N and stainlesssteel.Teflon® seat or BUNA-N seat disc.

Available OptionsClosing cap. T-Handle. Also available withdrilled and tapped spring chamber fordifferential service.

Note (1) Steel springs are furnished asstandard. Stainless springsfurnished for higher ranges andfor all cryogenic valves.

Note (2) Stainless Steel valves availablewith 200-400 psi range. Consultfactory.

Note (3) For steam service, werecommend a Max. differentialpressure of 150 psi to preventseat erosion.

Reduced Pressure Ranges (psig)

1/2" 3/4" 1"2-3010-5030-12550-150

2-2010-3530-7550-110105-150

2-2010-4520-6055-10090-150

Type B-95

Steel Steel SteelSize Spring Size Spring Size Spring

Type BBC is a direct acting, single seated,spring loaded diaphragm-type pressurereducing and regulating valve thatautomatically reduces a high pressure to alower pressure and maintains the lowerpressure within reasonably close limits. Itis available in 3/8" through 11/2" sizes andmay be fitted with either a cast iron orbronze body.

The Type BBC regulator is designed forheavy oil service (Bunker C and othergrades), as well as dirty liquids or fluidswith a high viscosity. These valves are wellsuited for systems having a maximumoperating temperature of 180°F whenfitted with a BUNA-N diaphragm andsystems with a maximum operatingtemperature of 400°F when fitted with a Monel® metal diaphragm. Type BBCregulators are equipped with a stainlesssteel piston and seat as standard.

Depending on the setting of the adjustingspring installed, delivery pressures may beadjusted from a minimum of 2 psi to a maximum of 200 psi. The range ofadjustment for each of the various springsthat may be installed is shown in the Spring Range Table underSpecifications, Page 8.

The table shows the standard factory trim(piston, piston seat, and diaphragm) as

well as the inlet pressure maximums forthe Type BBC Heavy Oil or Viscous Fluidsregulators. Valves will normally befurnished as indicated, however, othercombinations of body material, piston-cylinder and diaphragm are available onspecial order.

The Type BBC Heavy Oil and Viscous Fluid regulator incorporates a radicaldeparture from the conventional regulatorvalve design, featuring a “universal joint”type seating arrangement which insuresfree valve operation. As a result of thisdesign there are no small ports or closetolerances that would prevent dependableperformance. Like other Series Bregulators, the working parts are easilyaccessible without removing the valve fromthe line. The standard regulator is fittedwith a square head adjusting screw andlock nut arrangement. For a smalladditional charge, a T-handle or ahandwheel may also be fitted.

Note: If downstream pressure control is critical to the safety of the installation,then the downstream side should beprotected by a safety relief valve set torelieve at the maximum safe limit, but at least 10 psi higher than the pressureregulator's delivery setting.

BBC Heavy Oil or Viscous Fluids

Description/Application

Service Iron Bronze SS BUNA-N Monel®

MaximumInitial

Pressure(psig)

MaximumReducedPressure(psig)

BodyMaterial

DiaphragmStock

PistonandSeat

Oil up to180°F

Oil 180°Fto 400°F

200400150250

125200125200

X

XX

X

XXXX

XX

XX

Page 8: CASH VALVE B SERIES PRESSURE REGULATORS - … - B Series - TEMPRESCO.pdf · CASH VALVE B SERIES PRESSURE REGULATORS Copyright © 2012 Pentair CAVMC-0509-US-1212 page 3 Optional Differential

page 8 CAVMC-0509-US-1212 Copyright © 2012 Pentair

CASH VALVE B SERIESPRESSURE REGULATORS

5500 WAYZATA BLVD # 800, MINNEAPOLIS, MN 55416 WWW.PENTAIR.COM/VALVESCash Valve; 953 Old U.S. Highway 70; Black Mountain, NC 28771; Phone: 800-879-2042 • WWW.CASHVALVE.COMAll Pentair trademarks and logos are owned by Pentair, Inc. All other brand or product names are trademarks or registered marks of their respective owners. Because we are continuously improving our products andservices, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer.

Dimensions and Weights: The dimensionsand weights stated for the 3/8" through11/2" Series B regulators as shown in the table on page 4 also apply to the Type BBC – Heavy Oil or Viscous FluidsRegulator.

Capacity Information: For specificcapacity information, consult the factorygiving the pressure conditions that applyto your system.

2-15

2-152-152-202-20

10-502-3510-3010-4010-3010-30

40-8020-5020-7530-6020-10020-100

75-15040-12060-12550-150100-150100-150

125-200100-200100-200100-200100-200100-200

Spring Ranges (in psi)Size3/8"1/2"3/4"1"11/4"11/2"

Materials of Construction Part DescriptionAdjusting SpringSpring HousingPressure PlateDiaphragmDiaphragm Gasket(For Metal Diaphragms only)

Body

SteelCast Iron or BronzeCast IronBUNA-N or Monel®

Aramid Fiber

Cast Iron or Bronze

Materials Part DescriptionPusher Post SeatBody SeatBottom Plug GasketPistonPusher PostPiston Spring

Brass303 Stainless SteelCopper/Fiber303 Stainless SteelMonel®Monel®

Materials

How To Order To order, specify Cash Valve type by specific series designation (i.e. B Series). Also state the following:1. Valve size2. Service (water, air, oil, etc.)3. Inlet pressure4. Outlet or delivery pressure range and setting5. Maximum required flow rate6. System operating temperature7. Optional features, if any, as described for a specific valve.

Notes:1. NPTF, also referred to as “Dryseal” thread, is designed to provide a more leak-free seal without the

use of Teflon tape or other sealant compound. NPTF threads are interchangeable with NPT threadsand are standard on all Cash Valve products.

2. Series B valves are also available with special modifications. Cash Valve will be pleased to assist you in selecting the regulator features that are needed to meet the service requirements of yourparticular system. Consult the factory for details.

Specifications