CADENZA 3m CD‐C18 HPLC Columns
Up to 2000,000 Plates/m the same or more than UPLCtm Columns
A Revolution in Column Efficiency
Compare Cadenza CD-C18
Use any U/HPLC or LC-MS System You can get twice the throughput with the same or better resolution and you don’t need to buy an Ultra HPLC System. Use with any U/HPLC or LC‐MS System.
High Throughput Columns
Cadenza CD-C18 Phase Structure
Chromatographic Characteristics
Cadenza CD-C18 pH Tolerance
This data shows the pH stability using the Cadenza stationary phase. In aqueous eluants of acid and alkali with no organic solvent, we measured the rate of change in column durability after a constant period of exposure. Conven-tional ODS columns showed a huge change in column life with acidic and al-kali eluants. The cause of this is hydro-lytic degradation of the ODS and end‐capping functional groups. The pH used in the experiment was outside that toler-ated by conventional columns.
Cadenza CD‐C18, however, can handle these severe conditions. There is little change in retention or binding strength under these conditions. This is one of many points proving the power of polymeric end‐capping, the most superior stationery phase design technology. By using Cadenza CD‐C18, you will no longer face the traditional problems moving from low pH to high pH mobile phases, finding a new durability in your columns, discover the Cadenza ad-vantage.
+44 (0) 1420 549922 +44 (0) 1420 84254
OTHER FORMATS AVAILABLE FROM NANO TO PREP For more information or to place an order contact:
[email protected] PO Box 275, ALTON, Hampshire, GU34 9FJ, United Kingdom
www.arcsciences.com
4.6mm ID, 3μm C18
CD001 Cadenza CD-C18 (30x4.6mm) 3um, ODS, end-capped CD002 Cadenza CD-C18 (50x4.6mm) 3um, ODS, end-capped
CD003 Cadenza CD-C18 (75x4.6mm) 3um, ODS, end-capped
CD004 Cadenza CD-C18 (100x4.6mm) 3um, ODS, end-capped CD005 Cadenza CD-C18 (150x4.6mm) 3um, ODS, end-capped CD006 Cadenza CD-C18 (250x4.6mm) 3um, ODS, end-capped CD007 Cadenza CD-C18 (500x4.6mm) 3um, ODS, end-capped
2mm ID, 3μm C18
CD029 Cadenza CD-C18 (20x2mm) 3um, ODS, end-capped
CD021 Cadenza CD-C18 (30x2mm) 3um, ODS, end-capped CD022 Cadenza CD-C18 (50x2mm) 3um, ODS, end-capped CD023 Cadenza CD-C18 (75x2mm) 3um, ODS, end-capped
CD024 Cadenza CD-C18 (100x2mm) 3um, ODS, end-capped CD025 Cadenza CD-C18 (150x2mm) 3um, ODS, end-capped CD026 Cadenza CD-C18 (250x2mm) 3um, ODS, end-capped
1mm ID, 3μm C18
CD011 Cadenza CD-C18 (30x1mm) 3um, ODS, end-capped
CD012 Cadenza CD-C18 (50x1mm) 3um, ODS, end-capped CD013 Cadenza CD-C18 (75x1mm) 3um, ODS, end-capped CD014 Cadenza CD-C18 (100x1mm) 3um, ODS, end-capped CD015 Cadenza CD-C18 (150x1mm) 3um, ODS, end-capped CD016 Cadenza CD-C18 (250x1mm) 3um, ODS, end-capped
ARC Sciences is the Exclusive Distributor of Imtakt products in the UK and Ireland. All trademarks are the property of their rightful owners
Ordering Information