40
CABLE-TV NETWORKS: HFC PRODUCTS & MONITORING

CABLE-TV NETWORKS: HFC PRODUCTS & …smartel.rs/wp-content/uploads/2016/03/Catalogue-HFC-2015.pdf · 7 HFC-COMPONENTS FOSTRA-F NETWORK MONITORING FOSTRA-F Microreceiver for Fibre

Embed Size (px)

Citation preview

CABLE-TV NETWORKS: HFC PRODUCTS & MONITORING

7000

0147

Editi

on 4

2

3

TYPE DESCRIPTION PAGE

DELTANET Monitoring Software solution 4

Overview Amplifiers 1 GHz 9

Overview Amplifier Plug-In modules 10

BKE-P/BKE-PS House amplifier Profi-Line 1GHz 11

BKD-SF House amplifier Profi-Line 1GHz 13

LHE-P Line- and Distributionamplifier 1GHz 14

LHE Line- and Distributionamplifier 1GHz 16

LHD Line- and Distributionamplifier 1GHz 18

NVD-ED Line- and Distributionamplifier Expert-Line 1GHz 20

Overview Amplifiers 1.2 GHz 23

Overview Amplifier Plug-In modules 24

BKD G House amplifier Profi-Line 1,2GHz 25

LHD G/GR Line- and Distributionamplifier 1,2GHz 27

NVD G/GR Line- and Distributionamplifier Expert-Line 1,2GHz 29

GE Gain Extender 1,2 GHz 32

AGC/VM/AM System modules for Line- and Distributionamplifier 33

RV Return way modul for House amplifier 34

RLK Return way modul for Line- and Distributionamplifier 34

LPF/HPF Low- and Highpass Filter 35

NHP Return way - Ingressfilter 35

PAD/PAD-L JXP-PAD’s attenution 36

PG Connectors, Accessories 37

HÜP BK-Networktermination point Profi-Line 38

ZGV-A 2-way apartment-amplifier 39

4

DELTANET INTELLIGENT MONITORING SOFTWARE SOLUTION

DELTANET NMS software for monitoring and troubleshooting your FTTx and cable networks Powerful non-proprietary monitoring software to manage your network

HJ Module-oriented NMS-solution for: HFC, fibre optics, FOSTRA-F, FOSTRA-D, head end devices, provisioning

HJ Graphical user interface for display of all parameters of your net-work and the network topology

HJ Automatic analysis feature for ingress fighting and error analysis in collaboration with our managed components

HJ A highly powerful analysis tool lets you quickly locate sources of interference on the network by evaluation of important parameters of the CMTS and the cable modem in conjunction with managed components.

HJ Supported standards and protocols: SNMP, SOAP, HTTP, Telnet, XML, XSLT and JavaHJ Integration and capture of your managed components in the

DELTANET is possible with intelligent Smart Phone Application (FOSTRA-F) in conjunction with a database system – this saves the installer considerable time during commissioning while visuali-zation is made within a few minutes

HJ Take advantage of our sophisticated service and software maintenance system

HJ DELTANET is suitable for FOSTRA-F, FOSTRA-D – but also for the integration of multi-vendor components

HJ FOSTRA-F = FSK-Monitoring FOSTRA-D = DOCSIS-Monitoring

5

HFC-

COM

PON

ENTS

SNMP clientwww client

SNMP clientwww client

HEC(open socket)

SNMP clientwww client

SNMP clientwww client

Server, DB(Web server, SNMP server)

Fostra-F endpoints

Fostra-F endpoints

Fostra-F endpoints

Data base synch. MAC-Adr. scan

Position

DELTANET NMS software for monitoring and troubleshooting your FTTx and cable networks Powerful non-proprietary monitoring software to manage your network

HJ A smartphone or tablet PC connection via our app provides an auto-mated collection of your device locations

HJ With the App, a system check in relation with the head-end control-ler and DELTANET is possible in field

HJ Systematic recording of location data and documentation of the settings parameters of your network componentsHJ Access to DELTANET via internet connection HJ Device control by Android App: DELTA amplifier and

DELTA nodes

6

FOSTRA-F NETWORK MONITORING

Head End Controller für FOSTRA-F Cost-effective monitoring system for RFoG nodes and amplifiers to manage you network

HJ Head End Controller in operation with FOSTRA-F and DELTANET NMS-Software acc. to EN 60728-14

HJ Compact FSK-transmitter 19“, 1RU standard housingHJ Transmit frequency 868.3 MHz HJ Web server with DELTANET application, Linux operatedHJ 4 outputs with RF testpoint, optimal cluster splitting possibleHJ Electronic level adjustment of each outputHJ 10Base-T RJ-45 connection, USB-port

Application

Article-No.

TX-frequency MHz

Monitoring-Status LED

Bandwidth kHz

Spurious dBµV

Distortion dB

Transmitting level dBµV

RF test point

Data Speed Bps

Local Interface

Power supply V~/W

Dimensions mm

Weight kg

DELTANET / FOSTRA-F

5700 2115

868.3 MHz (other frequencies on request)

green

200

< 10

> 66

4 x 75...105 (set up by software)

4x-20dB

9600

10 Base-T RJ-45 and USB

185...265 / < 10

19“, 1 HE 482 x 260 x 44 / IP 20, In-door

2.0

Type HEC-1004

7

HFC-

COM

PON

ENTS

FOSTRA-F NETWORK MONITORING

FOSTRA-F Microreceiver for Fibre Nodes and Amplifiers Cost-effective monitoring system for RFoG nodes and amplifiers to manage your network

HJ FSK Microreceiver in operation with HEC 1004 and DELTANET NMS-Software acc. EN 60728-14

HJ Plug-able module for: ONH, ONB, BKD, LHD, NVD Typen (latest generation)HJ RX frequency 868.3 MHz HJ Monitoring status LED for displaying operation modeHJ Monitoring functions: DS ON/OFF, Burst Mode ON/OFF,

Ingress Detection Switch 0 / 6 / 45 dBHJ Intelligent integration into DELTANET via Smart Phone

applicationHJ Very low power consumption and cost-effective solution

for monitoring your network

Application

Article-No.

RX frequency MHz

Monitoring-Status LED

Bandwidth kHz

Spurious dBµV

Dynamic-Input level dBµV

Data Speed Bps

Local Interface

Power supply V~/W

Dimensions mm

Weight kg

ONH, ONB, BKD, LHD, NVD types (latest generation)

5700 1981

868,3 MHz (other frequencies on request)

green: 0 / 6 / 45dB, DS ON/OFF, Burst Mode ON/OFF

200

< 10

30...75

9600

RS-232

6-24V / < 0,4W@24V / <0.18W@12V

25 x 24 x 8

0.02

Typee FOSTRA-F

8

FOSTRA-D NETWORK MONITORING

FOSTRA-D- Kit DOCSIS Monitoring System for nodes and ampliifers to manage your network

HJ EURODOCSIS 2.0 Transponder in operation with DELTANET NMS-Software, SNMP capable

HJ Modular plugable: LHD, NVD types

HJ Monitoring status LED for displaying operation modeHJ Monitoring function: RX, TX Pegel, SNR, BER

Ingress Detection Switch 0 / 6 / 45 dB, otherHJ Intelligent integration into DELTANET via Smart Phone

applicationHJ Web-Gui https, RJ-45 connector, HMS MIB‘s available

Type Fostra D Kit I

NVD types

5700 2329

5-65 / 50-930

RX/TX/connect

0.2 / 6-8

2-256QAM / 4-1024 QAM

8...58 / -15...+15

10/100 Mbps

RJ 45

3.3V / 3.5W

80 x 50 x 10 / 0.02

Application

Article-No.

RX Frequencyrange US / DS MHz

Monitoring-Status LED

Bandwidth US / DS MHz

Modulation US / DS

RF-level TX / RX dBmV

Ethernet 10BaseT

Local Interface

Power supply V / W

Dimensions/Weight mm/kg

Fostra D Kit II*

LHD types

5700 2330

5-65 / 50-930

RX/TX/connect

0.2 / 6-8

2-256QAM / 4-1024 QAM

8...58 / -15...+15

10/100 Mbps

RJ 45

3.3V / 3.5W

80 x 50 x 10 / 0.02

* Fostra D Kit II with adapterboard and assembling kit

9

HFC-

COM

PON

ENTS

OVERVIEW AMPLIFIERS 1 GHzHouse amplifiers

Product family

BK

98 - 106

active, on board

PAD-JXP

F-connector

W / –

BK

99 - 109

active, modular

Step-Spin

F-connector

W / –

BKE-PS BKD-SF LHE-P

BK

110

active, on board

PAD-JXP

F-connector

W /–

Application

Output level dBuV (CTB/CSO > 60 dB)

Return way 65 MHz

Adjustments

RF-connections

Local / remote feeding

BKE-P

BK

98 - 101

active, on board

variable level attn.

F-connector

W / –

BKE-Series: PS: adjustments with variable level attenuators: no accessories needed for operation; P: adjustments with PAD’s: JXP PAD‘s needed for operation, values readableBKD-Series: SF: 1 GHz house amplifier, modular active return way, Step Spin adjustments: simply value adjustment and values directly readable, no accessories needed for operation, IDS – Ingress Detection Switch, FOSTRA-F compliant

Line extender- and Distribution amplifier

Type

Line extender and

distribution amplifier

110

1 / 2

electronical

active, on board

PG 11 oder 5/8”

W /W

LHE

Line extender and

distribution amplifier

110

1 / 2

electronical

active, modular

PG 11 oder 5/8”

W /W

LHD

Networkmanagement-

compl. distribution amplifier

2x114

2 / 2

electronical

active, modular

PG 11 oder 5/8”

W /W

NVD

Application

Output level dBuV (CTB/CSO > 60 dB)

No. of outputs

Adjustments

Return way

RF-connections

Local / remote feeding

Line extender- and Distribution amplifier LHE / LHD: Distribution amplifier NVD:FOSTRA-F and partially FOSTRA-D compliant; IDS – Ingress Detection Switch (partially) 2 active outputs possible; modulare return way Remote pwr. 10A depending on model; protection class IP 65 FOSTRA-F and FOSTRA-D compliant Remote pwr. 10A; protection class IP 65

10

HJ In the table hereafter the plug-ins for the following products are listed: HJ Amplifier: BKD-SF, LHD, NVD

OVERVIEW AMPLIFIER PLUG-IN MODULES

RLK 565

HPF 85-1

LPF 5-65

RLK 585

HPF 105-1

LPF 5-85

NHP 15-1

RV 65-22 EF

RV 65-32 EF

FOSTRA-F

FOSTRA-D Kit I

FOSTRA-D Kit II

VM 302

VM 202-2

AM 301-10 A

AM 301-10 B

AGC 203-1

AGC 303

AGC 403

Types NVD 9240 ED

Diplexer 65/85 MHz

Highpass Filter 85 MHz

Lowpass Filter 65 MHz

Diplexer 85/105 MHz

Highpass Filter 105 MHz

Lowpass Filter 85 MHz

Ingress-Filter 15 MHz

RW-Module 22dB

RW-Module 32dB

FSK-Tr.

DOCSIS-Tr.

DOCSIS-Tr.

2-way splitter

2-way splitter

Tap 10 dB Line out

Tap. 10 dB Tap out

AGC-Module

AGC-Module

AGC-Module

LHD 41 LHD 41 ED

5700 2095

5700 2297

5700 2295

5700 2096

5700 2298

5700 2296

5700 2116

5700 2432

5700 1956

5700 1981

5700 2329

5700 2330

5700 2092

5700 1674

5700 2093

5700 2117

5700 2054

5700 2091

5700 2493

BKD-SF LHE 40

1 GHz - Amplifiers

Article No. Description

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

Glossar y

JXP-PADs required for adjustment

Variable level attenuator included, no additional accessories required for level adjustment

Step-Spin adjustment, precise step control, values readable

Electronical adjustment, display, key pad, precise step control, values readable

1,2 GHz technology, DOCSIS 3.1 compliant

Remote management using FOSTRA-TechnologyFOSTRA-F FSK Monitoring FOSTRA-D DOCSIS Monitoring

1.2G

W

W

W

W

W

W

W

W

W

W

W

W

W

W

11

HFC-

COM

PON

ENTS

HOUSE AMPLIFIER PROFI-LINE BKE-PS

HJ KDG amplifier models are listed in the table below from model year 2014 on

HJ BKE-PS amplfier: return way on boardHJ Precise and reliable adjustments by variable level attn. (PS)

for level and slope controlHJ Low noiseHJ LED indicator for operation status HJ Kabel Deutschland certified

Types: BKE-PS

Article-No.

Description

Frequency range US / DS MHz

Gain US / DS dB

Adj. level/slope DS dB

Interstage slope DS (Jumper)

Noise US/DS dB

Output level CENLEC42 flat dBµV

Return way (KDG 1TS140) dB

Level adjustment US dB

Slope return way dB

Test point

Pwr. supply V~/W

Dimensions / Weight mm/kg

KDG class

Type

5700 2410 (PU:10)5700 2597 (PU:1)

ampl. with level attn.

5-65 / 85-1006

25 / 35

0 ... 20

0 / 7

5 / 6

100

medium load

0 ... 20

0/3/6/9

Input+Output

230/8

150x90x50/ 0.85

B (3.2) + C (3.2)

5700 2411 (PU:10)5700 2598 (PU:1)

ampl. with level attn.

5-65 / 85-1006

29 / 39

0 ... 20

0 / 7

5 / 6

101

medium load

0 ... 20

0/3/6/9

Input+Output

185-265/6

150x90x50/ 0.85

C (4.2)

5700 2409 (PU:10)5700 2596 (PU:1)

ampl. with level attn.

5-65 / 85-1006

25 / 33

0 ... 20

0 / 7

5 / 6

98

medium load

0 ... 20

-

-

230/8

150x90x50/ 0.85

B (3.1)

5700 2408 (PU:10)5700 2595 (PU:1)

ampl. with level attn.

5-65 / 85-1006

18 / 20

0 ... 20

0 / 7

5 / 6

100

medium load

0 ... 20

-

-

230/7,5

150x90x50/ 0.85

B (1.1)

BKE 22PS-KDG BKE 33PS-KDG BKE 36PS-KDG BKE 39PS-KDG

12

Upst

ream

Dow

nstre

am

BKE 41 P

HOUSE AMPLIFIER PROFI-LINE BKE-P

HJ Return way on board HJ Frequency range up to 1006 MHz HJ Extreme low distortion and noise on return way HJ JXP PAD‘s for level and slope adjustmentHJ Die-cast housing IP 20 for low operating temperature, long lifetime

and reliabilityHJ Very compact shape HJ LED indicator for operation statusHJ F-connectorsHJ UPC - Unitymedia KBW certified

Article-No.

Frequency range MHz

Gain dB

Noise dB

Linearity dB

Attenuation (PAD‘s) dB

Attenuation Interstage switchable dB

Slope dB

Interstage slope switchable dB

Outputlevel max.CSO / CTB > 60 dB, 42 CH flat dBµV95K n. UM ch grid 7dB slope dBµV

Frequency range MHz

Gain with fix 3dB slope dB

Noise dB

Attenuation (PAD‘s) dB

64 QAM, 3 carriers,120 dBµV, UM

Power supply V~

Power consumption W

Test point F -20 dB

Burst protection kV

Connector

Dimensions mm

Weight kg

Type5700 2303

PU: 10

85 - 1006

33 ± 1

5

± 0.5

0 ,1,2... 20

0 ,1,2... 20

0/7

9899

5 - 65

23 ± 1

5

0 ,1,2... 20

< 1*10-8

230

8.0

output

2.0

F-connector

188 x 85 x 50

0.8

5700 2008

PU: 1

85 - 1006

20 ± 1

5

± 0.5

102104

5 - 65

20 ± 1

5

< 1*10-8

185-265

4.5

Input + output

4.5

F-connector

188 x 85 x 50

0.7

5700 2304

PU: 10

85 - 1006

35 ± 1

5

± 0.5

0 ,1,2... 20

0 ,1,2... 20

0/7

100 101

5 - 65

25 ± 1

5

0 ,1,2... 20

< 1*10-8

230

8.0

output

2.0

F-connector

188 x 85 x 50

0.8

BKE 33 P BKE 2220-1 BKE 36 P5700 2306

PU: 10

85 - 1006

41 ± 1

5

± 0,7

0 ,1,2... 20

0/6

0 ,1,2... 20

0/7

106108

5 - 65

32 ± 1

5

0 ,1,2... 20

< 1*10-8

185-265

7.0

Input + output

2.0

F-connector

188 x 85 x 50

0.7

5700 2305

PU: 10

85 - 1006

39 ± 1

5

± 0.5

0 ,1,2... 20

0/6

0 ,1,2... 20

0/7

103105

5 - 65

29 ± 1

5

0 ,1,2... 20

< 1*10-8

185-265

5.0

Input + output

2.0

F-connector

188 x 85 x 50

0.7

BKE 41 PBKE 39 P

13

HFC-

COM

PON

ENTS

HOUSE AMPLIFIER PROFI-LINE BKD-SF

HJ Prepared for FOSTRA-F network monitoringHJ 1 GHz bandwidth, modular return way (page 33) HJ Unique Step Spin technology - allows readable values and fast

adjustmentHJ No accessories needed for operation HJ Low noise by GaAs-FET IC‘s HJ Cable equivalent 0 / 5 / 10 dB on input selectableHJ Modular power supply allows an easy in field replacement or up-

grade - less service interruption, no new adjustment neededHJ With FOSTRA-F: IDS 0 / 6 / 45 dB on return switchable (option)

BKD xx SF: HJ Push-Pull amplifer with high output level (BKD 40SF)HJ MultiGainTech: gain switchableHJ Kabel Deutschland certified

Article-No.

Frequency range

Plug-in slot

Gain dB

Noise1 dB

Linearity1 dB

Slope Step Spin

Level Step Spin

Interstage slope

Interstage attenuation

Output level1 max.1

CSO / CTB > 60 dB, 42 Ch flat dBµV 95 K Unity Media grid, 7dB Slope dBµV

Power supply V~

Power consumption W

Test point F -20 dB

Burst protection kV

Connector

Dimensions / Weight mm/kg

5700 2160

40 - 1006

1

25/31 ± 1switchable

7

± 0.7

0/7 dB switchable

0/6 dB switchable

99 / 100102

230

3.6

Input + output

2.0

F-connector

170x85x50/ 0.7

BKD 30 SF

5700 1867

40 - 1006

1

29/35 ± 1switchable

7

± 0.7

0/7 dB switchable

0/6 dB switchable

105 / 105106

185-265

5.1

Input + output

2.0

F-connector

188x85x50/ 0.7

5700 1868

40 - 1006

1

34/40 ± 1 switchable

7

± 0.7

0/7 dB switchable

0/6 dB switchable

109 / 109110

185-265

8.3

Input + output

2.0

F-connector

188x85x50/ 0.7

BKD 35 SF BKD 40 SF

step attenuator slope 0...10 dB + 10dB; 2 dB step wide

step attenuator 0...10 dB + 5dB; 2 dB step wide

1 without returnway module

Type

BKD 40 SF

14

Upst

ream

Dow

nstre

am

HOUSE AMPLIFIER LHE-P

HJ 1 GHz bandwidth HJ MultiGainTech 40/32 dB HJ JXP PADs for level and slope adjustment HJ Reliable adjustment of all values over life timeHJ Cable simulator on input HJ Extreme low distortion and noise on return wayHJ Input/Output horizontal or vertical assemblyHJ Excellent linearity up to 1 GHzHJ Alu die-cast housing IP 65, strand mount possibleHJ UPC - Unitymedia KBW certified

Article-No.Frequency range MHz

Gain dB

Linearity dB

Cable simulation dB

Attenuation dB

Slope dB 0-point loss dB

Interstage attenuation dB

Interstage-slope dB

Return loss Input/Output dB

Return loss Input/Output dB

Output level 41 Ch, CENELEC, CSO/CTB > 60 dB 7dB Slope dBµV

Output level 95 K, UM-ch grid, 7 dB slope dBµV

Operation level 95 K, UM-ch grid, 7 dB slope dBµV

Frequency range MHz

Gain dB

Linearity dB

Attenuation input dB

Slope dB

Attenuation output dB

Return loss Input/Output dB

Noise

Outputlevel-BER at 120 dBµV

64 QAM, 3 carrier,120 dBµV, UM dBµV

Pwr. supply V~

Pwr. consumption W

Dimensions / weight mm/kg

Connector

Type LHE 41 P

5700 193685-1006 (Diplexer on board)

32/40, switchable

± 0.5

0,1,2,3…10, plug able JXP-PADs

0,1,2,3…20, plug able JXP PADs

0,1,2,3…20, plug able JXP-PADs± 0.5, at 1 GHz

0,1,2,3…10 with PADs

0/7/10 with PADs

18 -1.5 dB, Octave, Reference 47 MHz

< 6, Tu ≤ 40° C

113/112, without K2

110, CTB/CSO > 60 dB; BER < 1*10-9

108

5-65

22/32, switchable

± 0.8

0,1,2,3…15, pluggable JXP-PADs

0,1,2,3…12, pluggable JXP-PADs

0,1,2,3…20, pluggable JXP-PADs

18, 5-65 MHz

5, Tu ≤ 40° C

< 1*10-8

185 - 265

14.5 max. incl. active return way

225x180x95/ 1.8

PG 11/F-connector included

15

HFC-

COM

PON

ENTS

HOUSE AMPLIFIER LHE-P

16

LINE EXTENDER-/ DISTRIBUTION-AMPLIFIER LHE

HJ 1 GHz bandwidth HJ Interrupt free electronic adjustment, basic settings without

additional accessoriesHJ 7-Segment display, simply to adjust by keypad HJ MultiGainTech 41/30 dB HJ AGC module available HJ High output level by GaAs-FETHJ 2 outputs, Input/Output horizontal or vertical assemblyHJ LED indicator for operation status HJ Alu die-cast housing IP 65, strand mount possible

Upst

ream

Dow

nstre

am

Article-No.Frequency range MHz

Gain dB

Linearity dB

Slope dB 0-point loss dB

Interstage slope dB

Attenuation dB

Interstage attn, slot. UPP1/UPP2 dB

Interstage slope, slot UPP1/UPP2 dB

Testpoint input dB

Testpoint output dB

Return loss In/Out dB

Noise dB

Outputlevel 42 Ch, CENELEC, flat dBµV

Outputlevel 42 Ch, CENELEC, 7dB slope dBµV

Frequency range MHz

Gain passive /active dB

Linearity dB

Slope (Output) dB

Attenuation (Output) dB

Input slot UPP3 dB

Interstage attenuation dB

Testpoint 5 - 65 MHz dB

Noise dB

Outputlevel 2nd order, -60 dB dBµV

Outputlevel 3rd order, -60 dB dBµV

Outputlevel-BER at 120 dBµV medium load 3 carrier 16 QAM BER

Power supply V~

Power consumption W

Dimensions / Weight mm/kg

Connector

Type LHE 40-1 LHE 40-1R

85-1006 (Diplexer on board)

40, to 30 dB switchable

± 0,5

0 ... 20, 1 dB steps adjustment, electronical ± 0,5, at 1 GHz

0/6, switchable

0 ... 20, 1 dB steps adjustment, electronical

0,1,2, ... 20 JXP-Pads for 1 dB step adjustment

3,6,9,12 with EZL/EZP adjustment

-20 ± 1.5 dB, F-connector, internal

-20 ± 0.75 dB, F-connector, internal

-20 ± 1.5 dB/Octave, min. -12 dB at 1 GHz

6,5 Tu ≤ 40° C

110, CTB/CSO > 60 dB

113, CTB/CSO > 60 dB

5-65 (Diplexer on board)

-4 / 24 / 32

± 0.5

0 ... 20, 1 dB steps adjustment, electronical

0 ... 20, 1 dB steps adjustment, electronical

0,1,2, ... 20 JXP-Pads in 1 dB steps adjustable

0 / 8, switchable by jumper

-20 ± 0.75 dB, F-connector, 2x internal

6, Tu ≤ 40° C

108, DIN 45004A1

116, DIN 45004B

1*10-6 (KDG 1TS140)

185 - 265 local pwr. or. 28 - 65 V remote pwr. 10 A feed through

14.5 max. active return way

225 x 180 x 95/ 1.8

PG 11 thread (connectors excluded)

5700 1626 (local pwr.) 5700 1627 (remote pwr.)

For the necessary plu-in modules please refer to the table on page 10.

17

HFC-

COM

PON

ENTS

LINE EXTENDER-/ DISTRIBUTION-AMPLIFIER LHE

18

LINE EXTENDER-/ DISTRIBUTION-AMPLIFIER LHD

HJ ,Prepared for network management systemHJ 1 GHz Bandwidth, modulare return way by diplexerHJ Interrupt free electronic adjustment, get it operable without

additional accessoriesHJ 7-segment display, simply to adjust by keypad HJ Extended up stream bandwidth to 105 MHz to configure by diplexer HJ AGC module available HJ 2 outputs, IN/OUT connectors in vertical or horizontal positionHJ Compact alu die-cast housing acc. IP 65, strand mountableHJ With FOSTRA-F: IDS 0 / 6 / 45 dB switchable at the return HJ FOSTRA-D (DOCSIS transponder) LHD 41 ED / R-ED Version

HJ FOSTRA-F FSK-RX HJ FOSTRA-D DOCSIS-Transponder

Upst

ream

Dow

nstre

am

Article-No.

Frequency range MHz

Gain dB

Linearity dB

Slope dB 0-point loss dB

Interstage slope dB

Attenuation dB

Interstage attn., slot UPP1 dB

Cablesimulation dB

Testpoint input dB

Testpoint output dB

Return loss In/Out dB

Noise dB

Outputlevel 42 Ch, CENELEC, flat dBµV

Outputlevel 42 Ch, CENELEC, 7dB slope dBµV

Frequency range MHz

Gain passive / active dB

Linearity dB

Slope (Output) dB

Attenuator (Output) dB

Input slot UPP2 dB

Ingress Detection Switch dB

Slope frequency point dB

Noise dB NPR/CNIR @ 35MHz, 65MHz noise bw

Output-BER at 120 dBµV full load 6 carrier 16 QAM BER

Power supply V~

Power consumption W

Dimensions / Weight mm/kg

Connector

Type LHD 41 LHD 41 R

5-1006 (return way ampl. 105 MHz on board, modular diplexer)

40, to 30 dB ± 1 switchable

± 0.5

0 ... 25, 1 dB step adjustment, electronical ± 0.5, at 1 GHz at 862 MHz switchable

0...15, electronical adjustment

0 ... 20, 1 dB step adjustment, electronical

for JXP-PAD‘s useable

0 / 5 / 10 by jumper switchable

-20 ± 1.5 dB, F-connector, internal

-20 ± 0.75 dB, F-connector, internal

18dB @ 40MHz -1.5 dB/Octave

typ. 6.5 Tu ≤ 40° C

110, CTB/CSO > 60 dB

113, CTB/CSO > 60 dB

5-105 (configuration with modular diplexer)

-4.5 / 26

± 0.5

0 ... 10, 1 dB step adjustment, electronical

0 ... 20, 1 dB step adjustment, electronical

for additional low pass filter LPF 5-85 or JXP-PAD‘s

0 / 6 / 45, switchable by FOSTRA

65/85 switchable by jumper

6.5 Tu ≤ 40° C

50dB @ -46dBmV/Hz input level, 24dB Dynamic range

1*10-6 (acc. KDG 1TS140)

16.3 active return way

225 x 180 x 95/ 1.8

PG 11 thread (connectors excluded)

5700 2098 LHD 41 R (remote pwr.)5700 2823 LHD 41-1 R (Line-OUT, remote pwr.)5700 2100 LHD 41 R-ED (DOCSIS, remote pwr.)

185 - 265 V local pwr. 28 - 65 V remote pwr.

10 A feed through

5700 2097 LHD 41 (local pwr.) 5700 2822 LHD 41-1 (Line-OUT) 5700 2099 LHD 41 ED (DOCSIS)

19

HFC-

COM

PON

ENTS

LINE EXTENDER-/ DISTRIBUTION-AMPLIFIER LHD

20

LINE EXTENDER-/ DISTRIBUTION-AMPLIFIER NVD

FOSTRA-D transponder acc. to EURODOCSIS-Standard 2.0

The following parameters can be monitored and controlled via the trans-ponder:

HJ QoS information such as C/N, BER, MHz, HF-level etc. HJ Return way Ingress-Control-Switch HJ Temperature HJ Identification of the amplifier type and place of installationHJ Other control and monitoring functions

Key benefitsHJ Manageable 1GHz trunk and line extender for modern

HFC-architectures

HJ Flexible transponder solution with DOCSIS-transponder FOSTRA-D or FSK FOSTRA-F microreceiver used to control and monitor with Webbrowser WebGui

HJ Manageable by DELTANET

HJ Solid alu die-cast housing, protection class IP 65

HJ Built in return amplifier, extended bandwidth to 105 MHz configurable via modular diplexer

HJ Ingress-Control-Switch 0 / 6 / 45 dB.

HJ State of the art GaAs-FET-IC pre-stages and GaAs-FET MMIC final stage for excellent linearity, low noise and high output level

HJ All adjustments by electronic keypad and LED-display

HJ Electronic Interstage-slope and attenuation

HJ For automatic adjustment of temperature induced level variations an AGC module can be used

HJ Complete equipment and testpoints

Remark: Fittings are not included in delivery.

HJ FOSTRA-D DOCSIS-TransponderHJ FOSTRA-F FSK-RX

FOSTRA-F microreceiver for amplifier Cost-effective monitoring system for amplifier and nodes:

HJ Monitoring function: Ingress Detection Switch 0 / 6 / 45 dBHJ Monitoring status LED indicates the operational modusHJ RX frequency 868.3 MHz HJ Identification of the amplifier type and place of installation

21

HFC-

COM

PON

ENTS

LINE EXTENDER-/ DISTRIBUTION-AMPLIFIER NVD

HJ Controlable line- and distribution amplifier for interactive HFC-networks

HJ Two independent, active high power outputsHJ Flexible transponder solution with DOCSIS-transponder FOSTRA-D or FSK FOSTRA-F microreceiverHJ Electronic level and slope adjustmentHJ Flexible and future proof returnway with bandwidth extension to

105 MHz, configurable by modular diplexerHJ Ingress-Control-Switch 0 / 6 / 45 dB on return way HJ Low noise by GaAs-FET-IC pre-amplifier stagesHJ High output level using Power-Doubler GaAs-FET technologyHJ AGC ± 3.5 dB - module plugable HJ Power pass of 10 A, with overvoltage protection 6 kVHJ Compact alu-die cast housing IP 65

Upst

ream

Dow

nstre

am

Article-No.

Final stage

Frequency range MHz

Gain dB

Noise dB

Linearity dB

Attenuation input dB

Slope 862/1006 MHz dBInterstage slope + attenuation dB

Outputlevel max

CSO / CTB > 60 dB, 42 CH flat dBµV

Return loss dB

Frequency range MHz

Gain dB

Noise dB

Attenuation dB

Slope dB

lngress Detection Switch dB NPR/CNIR @ 35MHz, 65MHz noise bw

BER @ 120 dBµV BER (6 carrier QAM 16; 5,12 Msym/s)

Power supply V~

Power pass A

Hum-isolation dB

Power consumption

Testpoint inputTestpoint output

Burst- / Surge protection kV

Connector

Dimensions / Weight mm/kg

RF-IN/OUT connection

Type NVD 9240 ED

5700 2101

2 x Power Doubler GaAs-FET

5 - 1006

2 x 41 ± 1

typ. 6.5 Tu ≤ 40° C

± 0.7

0 ... 20

0 ... 200 ... 15

2 x 114

5 - 105 (configured by Diplexer)

26 ± 1

7

0 ... 20

0 ... 10

0 / 6 / 45 switchable with FOSTRA

50dB@ -46dBmV/Hz input level

< 1*106

(KDG 1TS140)

28-65

10

> 60

31 W (without transp.)

6 / 6

PG 11 oder 5/8”

250x220x100/ 3.0

2/2

NVD 9240 R-ED

-20 dB (F-connector, internal) bidirectional -20 dB (F-connector, internal) unidirectional

18 dB bei 40 MHz (-1.5 dB/Octave)

5700 2824

2 x Power Doubler GaAs-FET

5 - 1006

2 x 41 ± 1

typ. 6.5 Tu ≤ 40° C

± 0.5

0 ... 20

0 ... 200 ... 15

2 x 114

5 - 105 (configured by diplexer)

26 ± 1

7

0 ... 20

0 ... 10

0 / 6 / 45 switchable with FOSTRA

50dB@ -46dBmV/Hz input level

< 1*106

(KDG 1TS140)

185-265

10

> 60

31 W (without transp.)

6 / 6

PG 11 oder 5/8”

250x220x100/ 3.0

2/2

22

LINE EXTENDER-/ DISTRIBUTION-AMPLIFIER EXPERT-LINE NVD

23

HFC-

COM

PON

ENTS

OVERVIEW AMPLIFIERS 1.2 GHz

House amplifier/Line- and Distributionamplifier

Product family

BK

99 - 109

up to 1218

active, modular 204 MHz

Step-Spin

F-connector

W / –

BKD-G

Application

Output level dBuV

Downstream MHz

Return way

Adjustments

RF-connections

Local / Remote pwr.

LHD-G

Line- and Distribution-

amplifier

114

up to 1218

active, modular 204 MHz

electronical

PG 11 or 5/8”

W /W

GE

Networkmanagement-

compl. distribution amplifier

r

2x115

up to 1218

active, modular 204 MHz

electronical

PG 11 or 5/8”

W /W

NVD-G

BK

105

up to 1218

passive, mod. 204 MHz

JXP-PAD

5/8”

- / W

BKD - G: 1.2 GHz house amplifier, modular return way up to 204 MHz, FOSTRA-F compliant, IDS Ingress Detection Switch, Step-Spin

LHD/NVD: 1.2 GHz Line- and Distribution ampl., modular return way up to 204 MHz, FOSTRA-F / -D compliant, electronical adjustments

GE: 1.2 GHz Gain Extender - pimp up your network on dedicated areas, passive return way, JXP-PAD level adjustment

Glossary

JXP-PADs for adjustments required

Variable level attenuator included, no additional accessories required for level adjustment

Step-Spin adjustment, precise step control, values readable

Electronical adjustment, display, key pad, precise step control, values readable

1.2 GHz technology, DOCSIS 3.1 compliant

Remote management using FOSTRA-TechnologyFOSTRA-F FSK MonitoringFOSTRA-D DOCSIS Monitoring

1.2G

1.2G

24

HJ In the table hereafter the plug-ins for the following products are listed: HJ Amplifier: BKD-G, LHD-G, NVD-G, GE 1212 R

OVERVIEW AMPLIFIER PLUG-IN MODULES

RLK 565-1

HPF 85-1

LPF 5-65

RLK 585-1

HPF 105-1

LPF 5-85

NHP 15-1

RLK 5200

HPF 258-1

LPF 5-204

FOSTRA-F

FOSTRA-D Kit I

VM 302

AM 301-10 A

AM 301-10 B

AGC 303

AGC 403

CK 5-0

Type NVD 9243 GR

Diplexer 65/85 MHz

High pass filter 85 MHz

Low pass filter 65 MHz

Diplexer 85/105 MHz

High pass filter 105 MHz

Low pass filter 85 MHz

Ingress-Filter 15 MHz

Diplexer 204/254 MHz

High pass filter 258 MHz

Low pass filter 204 MHz

FSK-Tr.

DOCSIS-Tr.

2-way splitter

Tap 10dB line out

Tap. 10dB Tap out

AGC-Module

AGC-Module

Jumper-Module 0dB

LHD 43 GR

5700 2732

5700 2297

5700 2295

5700 2733

5700 2298

5700 2296

5700 2116

5700 2776

5700 2819

5700 2820

5700 1981

5700 2329

5700 2092

5700 2093

5700 2117

5700 2091

5700 2493

5700 2308

BKD-GArticle No. DescriptionW

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

GE 1212 R

25

HFC-

COM

PON

ENTS

Dow

nstre

amUp

stre

am

HOUSE AMPLIFIER PROFI-LINE BKD-G

HJ 1.2 GHz DS-bandwidth, modular return way up to 204 MHzHJ FOSTRA-F network monitoring preparedHJ Unique Step Spin technology - allows readable values and fast

adjustmentHJ No accessories necessary for operationHJ DOCSIS 3.1 compliant HJ Modular power supply allows an easy in field replacement or up grade - less service interruption, no new adjustment neededHJ Mit FOSTRA-F: IDS 0 / 6 / 45 dB on return switchable

BKD xx G: HJ Push-Pull amplifer with high output levelHJ Switchable De-emphasis

BKD 22 G BKD 38 G

* to configure by RLK diplexer

Type BKD 30 G

5700 2827

40 - 1218*

2

32/38 ± 1

± 0.8

6.5

0/5/10

0/6 dB switchable

0/6 dB switchable

109107

5-65/85/204*

28

± 0.5

0/6

0/10

0/6/45

< 1.0E-09

185-265

11.1

input + output

2.0

F-connector

188x85x50/ 0.7

5700 2826

40 - 1218*

2

24/30 ± 1

± 0.7

6.5

0/5/10

0/6 dB switchable

0/6 dB switchable

109107

5-65/85/204*

25

± 0.5

0/6

0/10

0/6/45

< 1.0E-09

185-265

10.4

input + output

2.0

F-connector

188x85x50/ 0.7

5700 2825

40 - 1218*

2

22 ± 1

± 0.7

6.5

0/5/10

0/6 dB switchable

106102

5-65/85/204*

21

± 0.5

0/6

0/10

0/6/45

< 1.0E-09

185-265

10.4

input + output

2.0

F-connector

188x85x50/ 0.7

step attenuator 0...10 dB + 10dB; 2 dB steps

step attenuator 0...10 dB + 5dB; 2 dB steps

1.2G

@ -8dBµV/Hz input level dynamic range = 24dB

step attenuator 0...10 dB ; 2 dB steps

step attenuator 0...10 dB ; 2 dB steps

Article-No.

Frequency range DS MHz

Slot for return way diplexer

Gain dB

Linearity dB

Noise dB

De-emphasis input dB

Slope Step Spin

Attenuation Step Spin

Interstage slope

Interstage attenuation

Outputlevel max.1

CSO / CTB > 60 dB, 42 Ch flat dBµV

110 Ch 256 QAM,flat, BER< 1.0E-09 dBµV

Frequency range US MHz

Gain dB

Linearity dB

Interstage slope dB

Interstage attenuation dB

Slope output dB

Attenuation output dB

Ingress Detection Switch dB

50dB NPR @ 35 MHz/65 MHz noise bw

BER @ 107 dBµV, 24 carrier QAM 256

Power supply V~

Power consumption W

Test point F -20 dB

Burst protection kV

Connector

Dimensions / Weight mm/kg

26

HOUSE AMPLIFIER PROFI-LINE BKD-G

BKD 30 G

27

HFC-

COM

PON

ENTS

LINE EXTENDER-/ DISTRIBUTION-AMPLIFIER LHD-G

HJ 1.2 GHz DS-bandwidth, modular return way up to 204 MHzHJ Prepared for network monitoring FOSTRA-FHJ Interrupt free electronic adjustment, basic settings without

additional accessoriesHJ 7-Segment display, simply to adjust by keypad HJ DOCSIS 3.1 compliantHJ AGC/ALSC module available HJ With FOSTRA-F: IDS 0 / 6 / 45 dB switchable at the return HJ 2 outputs, IN/OUT connectors in vertical or horizontal position HJ 10 A remote current feed through, surge protection 6kVHJ Compact alu die-cast housing acc. IP 65, strand mountable HJ FOSTRA-F FSK-RX

Upst

ream

Dow

nstre

am

Article-No.

Frequency range MHz

Gain dB

Linearity dB

Slope dB 0-point loss dB

Interstage slope dB

Attenuation dB

Interstage attn., slot UPP1 dB

Cablesimulation dB

Testpoint input dB

Testpoint output dB

Return loss In/Out dB

Noise dB

Output level 42 Ch, CENELEC, flat dBµV

110 Ch 256 QAM, 9 dB Slope

Frequency range MHz

Gain passive / active dB

Linearity dB

Slope (Output) dB

Attenuator (Output) dB

Input slot UPP2 dB

Ingress Detection Switch dB

Slope frequency point dB

Noise dB

50dB NPR @ 35 MHz/65 MHz noise bw

BER @ 107 dBµV with 24 carrier QAM 256

Power supply V~

Power consumption W

Dimensions / Weight mm/kg

Connector

Type LHD 43 G LHD 43 GR

LHD 43G 5700 2810 (local pwr.)

LHD 43-1G 5700 2829 (Line-OUT local pwr.)

LHD 43GR 5700 2811 (remote pwr.)

LHD 43-1GR 5700 2830 (Line-OUT rem. pwr.)

28 - 65 V remote pwr. 10 A feed through185 - 265 V local pwr..

40 - 1218 (return way ampl. 204 MHz on board, diplexer modular)

43, to 30 dB ± 1 switchable

± 0.5

0 ... 25, 1 dB step adjustment, electronical ± 0.5 at 1218 MHz, switchable to 1006 MHz

0...15, electronical adjustment

0 ... 20, 1 dB step adjustment, electronical

for JXP-PAD‘s

for JXP-PAD‘s

-20 ± 1.5 dB, F-connector, internal

-20 ± 0.75 dB, F-connector, internal

20dB @ 40MHz -1.5 dB/Octave

typ. 6.5 Tu ≤ 40° C

114, CTB/CSO > 60 dB

109 dBµV / BER < 1.0E-09

5-65/85/204 (configuration with modular diplexer)

-5 / 28

± 0.5

0 ... 10, 1 dB step adjustment, electronical

0 ... 20, 1 dB step adjustment, electronical

for additional low pass filter LPF x-xx or JXP-PAD‘s

0 / 6 / 45, switchable with FOSTRA

85/204 switchable by Jumper

6.5 Tu ≤ 40° C@ -6dBµV/Hz input level, 24dB dynamic range

< 1.0E-09

17.0 with active return way

225 x 180 x 95/ 1.8

PG 11 thread (connectors not included)

1.2G

28

LINE EXTENDER-/ DISTRIBUTION-AMPLIFIER LHD-G

29

HFC-

COM

PON

ENTS

1.2G

LINE EXTENDER-/ DISTRIBUTION-AMPLIFIER EXPERT-LINE NVD 1.2 GHz

FOSTRA-D Transponder acc. to EURODOCSIS-Standard 2.0

The following parameters can be monitored and controlled via the trans-ponder:

HJ QoS information such as C/N, BER, MHz, HF-level etc. HJ Return way Ingress-Control-Switch HJ Temperature HJ Identification of the amplifier type and place of installationHJ Other control and monitoring functions

Key benefitsHJ Manageable 1.2 GHz trunk and line extender for modern

HFC-architectures

HJ Flexible transponder solution with DOCSIS-transponder FOSTRA-D or FSK FOSTRA-F microreceiver used to control and monitor with Webbrowser WebGui

HJ Manageable by DELTANET

HJ Solid Alu-die cast housing, protection class IP 65

HJ Built-in return amplifier, extended bandwidth to 204 MHz configurable via modular diplexer

HJ Ingress-Control-Switch 0 / 6 / 45 dB.

HJ State of the art GaAs-FET-IC pre-stages and GaAs-FET MMIC final stage for excellent linearity, low noise and high output level

HJ All adjustments electronically operated by keypad and LED-display

HJ Electronic interstage-slope and attenuation adjustment

HJ For automatic adjustment of temperature induced level variations an AGC/ALSC module can be used

HJ Complete equipment and testpoints

Remark: Fittings are not included in delivery

HJ FOSTRA-D DOCSIS-TransponderHJ FOSTRA-F FSK-RX

FOSTRA-F microreceiver for amplifier Cost-effective monitoring system for amplifier and nodes:

HJ Monitoring function: Ingress Detection Switch 0 / 6 / 45 dBHJ Monitoring status LED indicates the operational modeHJ RX frequency 868.3 MHz HJ Identification of the amplifier type and place of installation

30

1.2G

LINE EXTENDER-/ DISTRIBUTION-AMPLIFIER EXPERT-LINE NVD-G

HJ 1.2 GHz DS-bandwidth, modular return way up to 204 MHzHJ Controlable line- and distribution amplifier

for interactive HFC-networksHJ Two independent, active high power outputsHJ Flexible transponder solution with DOCSIS-transponder FOSTRA-D or FSK FOSTRA-F microreceiverHJ Electronical level and slope adjustmentHJ DOCSIS 3.1 compliant HJ Ingress-Control-Switch 0 / 6 / 45 dB on return wayHJ Low noise by GaAs-FET-IC pre-amplifier stagesHJ High output level using Power-Doubler GaAs-FET technologyHJ AGC module available HJ Power pass of 10 A, with overvoltage protection 6 kVHJ Compact die-cast housing IP 65

Upst

ream

Dow

nstre

am

Article-No.

Final stage

Frequency range MHz

Gain dB

Noise dB

Linearity dB

Attenuation input dB

Slope 1006/1218 MHz dBInterstage Slope + Attnuation . dBCSO / CTB > 60 dB, 42 Ch flat dBµV110 Ch 256 QAM, 9 dB Slope dBµV

Return loss dB

Frequency range MHz

Gain dB

Noise dB

Attenuation dB

Slope dB

Ingress Detection Switch

50dB NPR@35 MHz/65 MHz noise bw

BER @ 107 dBµV with 24 carrier

QAM 256

Power supply V~

Power pass A

Hum-isolation dB

Power consumption

Testpoint inputTestpoint output

Burst- / Surge protection kV

Connector

Dimensions / Weight mm/kg

RF-IN/OUT connection

Type NVD 9243 G-ED

5700 2812

2 x Power Doubler GaAs-FET

40 - 1218

2 x 43 ± 1

typ. 7,0 Tu ≤ 40° C

± 0.5

0 ... 20

0 ... 200 ... 152 x 115

110 dBµV / BER < 1.0E-09

5 - 65/85/204 (with diplexer)

28 ± 1

7

0 ... 20

0 ... 10

0 / 6 / 45 switchable FOSTRA

< 1.0E-09

28 - 65 V remote pwr.

10

> 60

35 W (without transp.)

6 / 6

250x220x100/ 3,0

2/2 PG 11 thread

NVD 9243 GR-ED

5700 2831

2 x Power Doubler GaAs-FET

40 - 1218

2 x 43 ± 1

typ. 7,0 Tu ≤ 40° C

± 0.5

0 ... 20

0 ... 200 ... 152 x 115

110 dBµV / BER < 1.0E-09

5 - 65/85/204 (with diplexer)

28 ± 1

7

0 ... 20

0 ... 10

0 / 6 / 45 switchable FOSTRA

< 1.0E-09

185 - 265 V local pwr.

10

> 60

35 W (without transp.)

6 / 6

250x220x100/ 3,0

2/2 PG 11 thread

-20 dB (F-Buchse, intern) bidirectional -20 dB (F-Buchse, intern) unidirectional

18 dB bei 40 MHz (-1.5 dB/Octave)

@ -6dBµV/Hz input level dynamic range = 24dB

PG 11 (connectors not incl.)

31

HFC-

COM

PON

ENTS

LINE EXTENDER-/ DISTRIBUTION-AMPLIFIER EXPERT-LINE NVD-G

32

1.2G

GE 1212 R

GAIN EXTENDER 1.2GHz

HJ Applicable for simple network extension to 1.2 GHz HJ 1.2 GHz bandwidth HJ Passive return way 204 MHz to configure by diplexerHJ Low gain, low noise by GaAs-FET IC‘s HJ JXP-PAD‘s for adjustments HJ Push-Pull stage with high output levelHJ Remote power with 10A feed throughHJ DOCSIS 3.1 compliant HJ Compact die-cast housing IP 65, 6 kV surge protected

Article-No.

Frequency range

Slot for return way diplexer RLK

Gain dB

Return way loss dB

Noise dB

Linearity dB

Slope (JXP-PAD)

Attenuation (JXP-PAD

0dB slope point MHz

Output level max.CSO / CTB > 60 dB, 42 Ch flat dBµV 110 Ch 256 QAM, BER < 1.0E-09 dBµV

Power supply V~

Power consumption W

Power pass A

Burst+Surge protection kV

Connector

Dimensions / Weight mm/kg

5700 2488

40 - 1218

2

12 ± 1

3

5,5 (< 1GHz) 6,5 (<1.2GHz)

± 0.5

with JXP-PAD 0...20 dB

with JXP-PAD 0...20 dB

1218

10598

30...65

3.5

10

6

2 x 5/8“- Connector

155x120x100/ 1.1

GE 1212 RType

33

HFC-

COM

PON

ENTS

1.2G

OVERVIEW AMPLIFIER PLUG-IN MODULES

AGC 403HJ AGC module for automatic gain and slope controlHJ 2-tone-controlled module HJ Upper and lower QAM channels will be used as reference pilotHJ Stable control over a wide temperatur rangeHJ LED-indicator for level and slope adjustment HJ Precise adjustment by potentiometer

Article-No.

Description

Frequency range MHz

Linearity dB

Through loss dB

Gain control dB

Slope control

Pilottone 1 MHz

Pilottone 2 MHz

Temperature control range

NVD 9xxx

LHD 4x

Dimension / Weight mm/kg

Type 5700 2091

AGC Module

5-1218

± 0.2

2

± 3dB (sum control)

-30...+60

W

W

29 x 34 x 10 / 0.05

AGC 303 5700 2493

AGC Module

5-1218

± 0.2

2

± 3dB

± 2dB

125 ...160

542...630

-30...+60

W

W

29 x 37 x 10 / 0.05

AGC 403

AGC 303HJ AGC sum level module for automatic gain control HJ Sum channel load will be used as reference pilotHJ Stable control over a wide temperatur rangeHJ Precise adjustment by potentiometer

Article-No.

Description

Frequency range MHz

Loss dB

Type

NVD 9xxx

LHD 4x

Type 5700 2092

2-way splitter

5-1218

4.5

W

W

VM 302

5700 2093

1-way tap

5-1218

1.3 / 10.0

Tap out

W

W

AM 301-10A

5700 2117

1-way tap

5-1218

1.3 / 10.0

Line out

W

W

AM 301-10B

AM/VM-Plug-in modulesHJ Taps- and splitter modules for LHD/NVD

For detailed application of VM/AM modules please refer to the respective block diagram (S.28/31)

34

RETURNWAY PLUG-IN MODULES FOR HOUSE AMPLIFIER BKD-SF

HJ For BKD-SF amplifier HJ IDS - Ingress Detection SwitchHJ Step Spin adjustment, readable valuesHJ High output levelHJ Excellent linearity

Type

Article-No.

Return way MHz

Gain dB

Attenuation dB

Slope dB

Linearity dB

Noise dB

Ingress Detection Switch dB

Output level KBW medium load dBµV 4 carrier QAM 64 BER

DS frequency range MHz

Loss dB

Power consumption W

5700 2432

5-65

23

0,2,4...16 dB

0/2/4/6

± 0.5

4.5

0 / 6 / 45 115

< 1*10-8

85-1006

- 1.0

1.6

5700 1956

5-65

32

0,2,4...16 dB

0/3/6/9

± 0.5

4.5

0 / 6 / 45 115

< 1*10-8

85-1006

- 1.0

1.7

RV 65-22 EF RV 65-32 EF

RETURNWAY PLUG-IN MODULES FOR LINE-/ DISTRIBUTION-AMPLIFIERS

HJ Diplexer-Modules RLKHJ For 1 GHz amplifier LHD 41 and NVD 9240HJ Return loss >20 dB at 47 MHz, -1.5 dB per octaveHJ Metal cover for solid protection and high screening immunityHJ Remark: multiple pieces per amplifier needed

Type

5700 2095

LHD 41 / NVD 9240

5-65

85-1006

0.5

> 50 per diplexer

30 x 35 x 8 / 0.05

RLK 565

5700 2096

LHD 41 / NVD 9240

5-85

105-1006

0.5

> 50 per diplexer

30 x 35 x 8 / 0.05

RLK 585

Article-No.

Application

Frequency range Upstream MHz

Frequency range Downstream MHz

Through loss dB

Isolation Up-/Downstream dB

Dim. / Weight mm/kg

35

HFC-

COM

PON

ENTS

RETURNWAY PLUG-IN MODULES FOR LINE-/ DISTRIBUTION-AMPLIFIERS

HJ Diplexer-Module RLKHJ For 1.2 GHz amplifier BKD-G/LHD-G/NVD-GHJ Return loss >20 dB at 47 MHz, -1.5 dB per octaveHJ Metal cover for solid protection and high screening immunityHJ Remark: multiple pieces per amplifier needed

Type

5700 2732

BKD-G/LHD 43G / NVD 9243G

5-65

85-1218

0.5

> 50 per diplexer

30 x 26 x 8 / 0.05

RLK 565-15700 2776

BKD-G/LHD 43G / NVD 9243G

5-204

258-1218

0.5

> 50 per diplexer

30 x 26 x 8 / 0.05

RLK 585-1Article-No.

Application

Frequency range Upstream MHz

Frequency range Downstream MHz

Through loss dB

Isolation Up-/Downstream dB

Dimens. / Weight mm/kg

1.2G

5700 2733

BKD-G/LHD 43G / NVD 9243G

5-85

105-1218

0.5

> 50 per diplexer

30 x 26 x 8 / 0.05

RLK 5200

High pass / low pass-filter plug-in modulesHJ For LHD/NVD to increase the isolation between US/DS HJ For pairwise use LPF/HPF depends on RLK diplexer configurationHJ E.g. 2 x RLK 565-1 requires 1 x LPF 5-65 + 1 x HPF 85-1HJ Style JXP 1“, 3-PIN

Type LPF 5-65

5700 2295

LHD / NVD

5-65

LP stopp

0.4

> 30

8 x 28 x 4 /0.01

Article-No.

Application

Frequency range Upstream MHz

Frequency range Downstream MHz

Through loss dB

Stopp band isolation dB

Dimens. / Weight mm/kg

LPF 5-85 LPF 5-204 HPF 85-1 HPF 105-1 HPF 258-1

5700 2296

LHD / NVD

5-85

LP stopp

0.4

> 30

8 x 28 x 4 /0.01

5700 2820

LHD / NVD

5-204

LP stopp

0.5

> 30

8 x 28 x 4 /0.01

5700 2297

LHD / NVD

HP stopp

85-1218

0.5

> 30

8 x 28 x 4 /0.01

5700 2298

LHD / NVD

HP stopp

105-1218

0.5

> 30

8 x 28 x 4 /0.01

5700 2819

LHD / NVD

HP stopp

285-1218

0.5

> 30

8 x 28 x 4 /0.01

Type NHP 12-1

5700 2815

LHD / NVD

12-204

0.1-10

0.4

> 40

8 x 28 x 4 /0.01

Article-No.

Application

Frequency range Upstream MHz

Stopp band MHz

Through loss dB

Stopp band isolation dB

Dimens. / Weight mm/kg

NHP 15-1 NHP 18-1

5700 2116

LHD / NVD

15-204

0.1-13

0.4

> 40

8 x 28 x 4 /0.01

5700 2814

LHD / NVD

18-204

0.1-15

0.4

> 40

8 x 28 x 4 /0.01

Ingress high pass filter - plug-in moduleHJ For LHD/NVD to prevent Ingress distortion jamming on return wayHJ Style JXP 1“, 3-PIN

36

Article-No.

Loss dB

Type

1016 1523

0

PAD 0

1016 1524

1

PAD 1

1016 1525

2

PAD 2

1016 1526

3

PAD 3

1016 1527

4

PAD 4

1016 1528

5

PAD 5

1016 1529

6

PAD 6

Article-No.

Loss dB

Type

1016 1530

7

PAD 7

1016 1531

8

PAD 8

1016 1532

9

PAD 9

1016 1533

10

PAD 10

1016 1534

11

PAD 11

1016 1535

12

PAD 12

1016 1536

13

PAD 13

Article-No.

Loss dB

Type

1016 1537

14

PAD 14

1016 1538

15

PAD 15

1016 1539

16

PAD 16

1016 1540

17

PAD 17

1016 1541

18

PAD 18

1016 1542

19

PAD 19

1016 1543

20

PAD 20

Length 25.4 mm (1”)

ATTENUATION JXP-PADS

HJ Fix attenuation-PAD’sHJ 1 dB step values for gain and slope adjustmentHJ Plastic cover for solid protectionHJ Length 1” available

PAD SETBOX

TypeArticle-No.

Description

5700 2032

Setbox equipped with 630 pcs PADs

30 x 0, 1, 2 ... 20 dB PADs 1“

pre equipped unequipped

5700 2084

empty setbox with 21 separations

37

HFC-

COM

PON

ENTS

Article-No.

Description

Type

1016 1204

PG 11 - reduction ringPG 11 / 5/8”

PG 11m-5/8f

1016 1205PG 11

Blind cap

PG 11 PC

Article-No.

Description

Connector Pin length

Type

5700 1141

PG 11 - Adapter

PG 11 / 3.5/12 female

47 mm

PG11m-3,5/12f

5700 1291

PG 11 - Adapter

PG 11 / 3.5/12 female

17 mm

PG11m 3,5/12f

5700 1082

PG 11 - Adapter

PG 11 / F-female

47 mm

PG11m-Ff

1016 1203

PG 11 - Adapter

PG 11 / IEC-female

17 mm

PG11m-IECf

FITTINGS PG 11

38

~~TP 65 MHz

HP 5 MHz3 kV

Deemphasis3 dB

Deemphasis6 dB

OUT (NE 4)TP IN/OUTIN (NE 3)

S 3 S 4

S 5

S 6

S 2S 1

75 Ohm

ÜSA / 3 kV~~

Article-No.

Frequency range MHz

Isolation 5-65 MHz dB

Through loss dB

Linearity dB

Isolation In/Out at S1 at 75 Ω dB

Deemphase 470-1006 MHz dB

Surge- and Burst protection kV

Test point

Dimensions B x H x T mm

Weight kg

Network termination NE3

Return loss dB

Type

5700 1434

0.8

± 0.5

50

0 / 3 / 6 switchable

3

1 F-connector (switchable between in- and output)

100 x 90 x 45

0.3

75 Ohm (switchable)

-20 dB at 40 MHz / -1.5 dB/octave

HÜP 862 D

CATV-NETWORK TERMINATION POINT PROFI-LINE

HJ For broadband network termination between level 3 (street installa-tion) and level 4 (house installation)

HJ Alu die-cast housing, IP 54HJ Frequency range 5 to 1006 MHzHJ Switchable return way cut off filter built-inHJ Galvanic isolated inner conductorHJ Deemphase slope adjustableHJ Surge- and Burst protectionHJ Test point, between IN/OUT switchableHJ Plastic cover for solid protectionHJ Secured against unauthorized opening

5-1006without return way blocking

85-1006with return way blocking

40

39

HFC-

COM

PON

ENTS

Upst

ream

Dow

nstre

am

TV

TV

TV

LaptopCM

Laptop

CM

Laptop

CM

Receiver

TV

DOCSIS-STB

TVLaptop CMTV

HÜP

2-WAY APARTMENT-AMPLIFIER

HJ 2-way apartment-amplifier with active return way HJ Perfect for Multimedia-or DOCSIS-application,

Modem-, TV- or STB-extensionHJ For push on at antenna wall outletsHJ Active 2-way split to connect a cablemodem to one or more

multimedia wall outletsHJ Connection: 2 x F-female connector, 1 x F-male connectorHJ Including power adapter

Article-No.

Input

Outputs

Frequency range MHz

Gain dB

Noise dB

Linearity dB

OutputlevelCSO / CTB > 60 dB, 42 CH flat dBµVMA

2 / IMA

3 > 60 dB, DIN-level dBµV

Frequency range MHzGain dB

Linearity dB

Power supply V~

Power consumption W

Connector

Dimension B x H x T / Weight mm/kg

Type

5700 1631

1

2

85 - 1006

2x10

4.5

± 0.5

98112/113

5 - 652x10

± 0.7

230

0.5

2 x F-female connector, 1 x F-male connector

44 x 48 x 24 / 0.6

ZGV 12-65 A

HJ Perfect to extend multimedia wall outlets in case of to high loss or for

connection of a second cable modem or set top box with integrated

cable modem. Ideal to connect another appartment wall outlet.

Germany and Austria

DCT DELTA GmbH

Bodanrückstraße 1

D-78351 Bodman

Tel. +49 7773 929258

Fax +49 7773 929259

[email protected]

www.dct-delta.de

Schwitzerland

DELTA Swiss AG

Industriezone Schächenwald

CH-6460 Altdorf

Tel. +41 4161 91400

Fax +41 4161 91409

[email protected]

www.delta-swiss.ch

7000

0147

Editi

on 4