Contact: RectorSeal® 2601 Spenwick Drive, Houston, TX 713-263-8001 800-231-3345 713-263-7577 800-441-0051 rectorseal.comP F W
A CSW Industrials Company
P-J-15
Specification: SureSeal Plus model SS2009P Waterless Inline Trap Seal with integral pressure relief valve. Commercial grade HDPE plastic housing with proprietary heavy duty silicone diaphragm and EPDM soft rubber sealing gasket. Floor Rating ASSE 1072 AF GW.
Function: Installs into the outlet of drain bodies, drain hubs, or floor sinks to protect the trap seal from evaporation. Creates a physical barrier that blocks bugs, sewer gases and odors from escaping; PLUS, it holds back up to 5' of columnar (head) back flow pressure. Built-in pressure relief valve equalizes air pressure if needed. Provides waterless trap seal protection equivalent to water based trap primers.• New Construction: Used as a trap primer replacement or in conjunction with a trap primer to provide protection against escaping sewer gases
and protection from water/sewer backups. Eliminates the need to repair/replace trap primers when they fail, and/or prevents damage caused by backups.
• Retrofit: Used in situations where trap primers have failed or where trap primers were never installed and/or where protection from back flow is needed.
Benefits: Simple to install, eliminates the need for complex, time consuming, and expensive repairs to fix a failed trap primer or damage caused by water/sewer backup. No Guessing - SureSeal Plus has a built-in torque release and is installed with a 3/8" ratchet and extension. NO TRAP PRIMER NEEDED! ECO FRIENDLY PROVIDES 100% WATER SAVINGS EFFICIENCY OVER TRADITIONAL METHODS.
ICC-ES Listed: PMG-1070 IAPMO Listed: C-4165 U.S. Patent 9,010,363 Other Patents Pending
EXPANSION DISK
EXPANSION RING
STRAINER
FLOOR
SureSeal PLUS
DRAIN OUTLET
EXPANSION DISK
EXPANSION RING
STRAINER
FLOOR
SureSeal PLUS
DRAIN OUTLET
EXPANSION DISK
EXPANSION RING
STRAINER
FLOOR
SureSeal PLUS
DRAIN OUTLET
2" SureSeal® PLUS MODEL #SS2009P
WATERLESS INLINE DRAIN TRAP SEAL with BUILT-IN CHECK VALVE
The Green Solution
Expansion Disk
A00 RELEASED FOR PRODUCTIONN/A
APPROVEDDATEDESCRIPTIONREV.ZONE
REVISIONS
10/27/2015 DFC
ITEM NO. PART NUMBER DESCRIPTION QTY.
12-400-023 (2IN BACKFLOW CLIP) - REVA00
2IN BACK FLOW CLIP 1
22-400-017 (2IN TEST HOUSING) - REVH00
2IN LOWER BACKFLOW HOUSING 1
32-400-005 (2IN FLAPPER) - REVG00
2IN FLAPPER 1
42-400-015 (2IN TEST MEMBRANE) - REVE00
2IN MEMBRANE 1
52-400-016 (2IN BALL FLOAT) - REVA03
2IN BACKFLOW BALL FLOAT 2
62-400-022 (2IN BACKFLOW TOOL PLATE) - REVD00
2IN BACK FLOW TOOL PLATE 1
7
2-400-024-SA (2IN BackFlow Gasket SANTOPRENE) - REVC00
2IN UNIVERSAL GASKET 1
82-400-018 (2IN TEST UPPER HOUSING) - REVB00
2IN UPPER BACKFLOW HOUSING 1
92-400-019 (2IN TEST RING) - REVB00
2IN LOCKING BACKFLOW TEST RING 1
102-400-029 (2IN BACKFLOW 0-RING) - REVA00
2IN BACKFLOW O-RING 1
6
8
5
SECTION A-A1
3
4
9
10
PROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SURE SEAL MANUFACTURING. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SURE SEAL MANUFACTURING IS PROHIBITED.
THIRD ANGLE PROJECTION
D
C
B
AA
B
C
D
12345678
8 7 6 5 4 2 1
SH 1 OF 1CAD FILE: SolidWorksSCALE: NONE
SIZE REV.
B A00
APPROVALS
DATEDRAWN
CHECKED
MATERIAL
FINISH
DATE
01 - AUG - 2015DH
3
UNLESS OTHERWISE SPECIFIED
UNLESS OTHERWISE SPECIFIED:
2IN BACKFLOW ASSY
SS2009PLUS
N/A
N/A
RectorSeal
PER RMA "A3" COMMERCIAL
TOLERANCES:
(713) 263-8001
PART NO
DESCRIPTION
DFC
DIMENSIONS ARE IN INCHES
2601 Spenwick Drive
Houston, TX 77055 USA
01 - AUG - 2015
2
7
9
28.30 1.11
60.40 2.382.33
59.13
1.7644.83
1.9449.28
1.95
49.53
2.9374.40
6 REF1.07R27.05
AA
Expansion Ring
Body
SECTION A-A
28.30 1.11
60.40 2.382.33
59.13
1.7644.83
1.9449.28
1.95
49.53
2.93
74.40
1.07R27.05
AA
SECTION A-A
28.30 1.11
60.40 2.382.33
59.13
1.7644.83
1.9449.28
1.95
49.53
2.93
74.40
1.07R27.05
AA
SECTION A-A
28.30 1.11
60.40 2.382.33
59.13
1.7644.83
1.9449.28
1.95
49.53
2.93
74.40
1.07R27.05
AA
Contact: RectorSeal® 2601 Spenwick Drive, Houston, TX 713-263-8001 800-231-3345 713-263-7577 800-441-0051 rectorseal.comP F W
A CSW Industrials Company
P-J-15
Specification: SureSeal Plus model SS3009P Waterless Inline Trap Seal with integral pressure relief valve. Commercial grade HDPE plastic housing with proprietary heavy duty silicone diaphragm and EPDM soft rubber sealing gasket. Floor Rating ASSE 1072 AF GW.
Function: Installs into the outlet of drain bodies, drain hubs, or floor sinks to protect the trap seal from evaporation. Creates a physical barrier that blocks bugs, sewer gases and odors from escaping; PLUS, it holds back up to 5' of column water back flow. Built-in pressure relief valve equalizes air pressure if needed. Provides waterless trap seal protection equivalent to water based trap primers.• New Construction: Used as a trap primer replacement or in conjunction with a trap primer to provide protection against escaping sewer gases
and protection from water/sewer backups. Eliminates the need to repair/replace trap primers when they fail, and/or fix damage caused if the drain backs up.
• Retrofit: Used in situations where trap primers have failed or where trap primers were never installed and/or where protection from back flow drains is needed.
Benefits: Simple to install, eliminates the need for complex, time consuming, and expensive repairs to fix a failed trap primer or damage caused by water/sewer backup. No Guessing - SureSeal Plus has a built-in torque release and is installed with a 3/8" ratchet and extension. NO TRAP PRIMER NEEDED! ECO FRIENDLY PROVIDES 100% WATER SAVINGS EFFICIENCY OVER TRADITIONAL METHODS.
6
5
A-ASECTION3
10
4
97
2
THIRD ANGLE PROJECTION
D
C
B
AA
B
C
D
12345678
8 7 6 5 4 2 1
SH 1 OF 1CAD FILE: SolidWorksSCALE: NONE
SIZE REV.
B A00
APPROVALS
DATEDRAWN
CHECKED
MATERIAL
FINISH
3
PROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SURE SEAL MANUFACTURING. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SURE SEAL MANUFACTURING IS PROHIBITED.
DATE
01 - AUG - 2015
UNLESS OTHERWISE SPECIFIED
UNLESS OTHERWISE SPECIFIED:
3IN BACKFLOW ASSY
SS3009PLUS
N/A
N/A
RectorSeal
PER RMA "A3" COMMERCIAL
TOLERANCES:
(713) 263-8001
PART NO
DESCRIPTION
DFC
DH
DIMENSIONS ARE IN INCHES
2601 Spenwick Drive
Houston, TX 77055 USA
01 - AUG - 2015
DFC10/27/2015RELEASED FOR PRODUCTIONA00N/A
APPROVEDDATEDESCRIPTIONREV.ZONE
REVISIONS
ITEM NO. PART NUMBER DESCRIPTION QTY.
13-400-017 (3IN TEST HOUSING) REVL00
3IN BACKFLOW LOWER HOUSING 1
2
3-400-025-SI (3IN BACKFLOW MEMBRANE SILICONE) REVB00
3IN BACKFLOW MEMBRANE 2
33-400-028 (3IN BACKFLOW CLIP) - REVD00
3IN BACKFLOW RETAINER CLIP 1
43-400-005 (3IN FLAPPER) - REVD00
3IN FLAPPER 1
53-400-016 (3in BALL FLOAT) - REVA03
3IN BACKFLOW BALL FLOAT 1
63-400-018 (3IN TEST UPPER HOUSING) - REVD00
3IN BACKFLOW UPPER HOUSING 1
73-400-020 (3IN BACKFLOW RING) - REVB00
3IN BACKFLOW LOCKING RING 1
8
3-400-023-SA (3IN BACKFLOW GASKET SANTOPRENE) - REVD00
3IN BACKFLOW GASKET 1
93-400-022-NYLON (3IN BACKFLOW TOOL PLATE) - REVA00
3IN BACKFLOW TOOL PLATE 1
10 3in O-ring (2418T117) 3IN BACKFLOW O-RING 1
3.2081.28
AA
1
8
7
2.74 69.49
68.432.69
74.172.92
74.682.94
73.662.90
71.35 2.81
34.38 1.35
66.74 2.63
3.4086.46
ICC-ES Listed: PMG-1070 IAPMO Listed: C-4165 U.S. Patent 9,010,363 Other Patents Pending
EXPANSION DISK
EXPANSION RING
STRAINER
FLOOR
SureSeal PLUS
DRAIN OUTLET
EXPANSION DISK
EXPANSION RING
STRAINER
FLOOR
SureSeal PLUS
DRAIN OUTLET
EXPANSION DISK
EXPANSION RING
STRAINER
FLOOR
SureSeal PLUS
DRAIN OUTLET
3" SureSeal® PLUS MODEL #SS3009P
INLINE FLOOR DRAIN TRAP SEALER
The Green Solution
A-ASECTION
3.2081.28
AA
2.74 69.49
68.432.69
74.172.92
74.682.94
73.662.90
71.35 2.81
34.38 1.35
66.74 2.63
3.40
86.46
A-ASECTION
3.2081.28
AA
2.74 69.49
68.432.69
74.172.92
74.682.94
73.662.90
71.35 2.81
34.38 1.35
66.74 2.63
3.40
86.46
A-ASECTION
3.2081.28
AA
2.74 69.49
68.432.69
74.172.92
74.682.94
73.662.90
71.35 2.81
34.38 1.35
66.74 2.63
3.40
86.46