BOD-Especificaciones.pdf

Embed Size (px)

Citation preview

  • 8/10/2019 BOD-Especificaciones.pdf

    1/1

    423

    MBOD METERS

    Features:Exchangeable microbe electrode units

    make operation smoother and less time-consuming than loading and

    replacing conventional membranes.Electrode units may be used for one

    month continuously or for threemonths intermittently with standardsamples. (Electrode units should bestored in refrigerators when not takingmeasurements.)

    Front panel allows simple, pushbuttonoperation.

    Ease of replacement by installingelectrode units or tubing into theopened door in the front panel.

    Anti-reflux valves and antibacterialtubing reduce the frequency of

    maintenance.Bacteriostatic is mixed into standard

    and buffer solutions, so measurements are stable over the long term.

    BODT-1, Biological Oxygen Demand, With Integral Incubator

    Model BODT-1

    Measurement method Biosensor

    MeasurableLiquid samples containing soluble organic matter such

    as drainage and river water

    Measurement range0-20 mg/l (base Measurement range)Variable with pump rpm and sample

    Contact time

    Measurement time60 min/specimen

    (assuming calibration for each specimen)

    Calibration Single-point calibration with glucose glutamic solution

    Readout

    LCD, 20 characters x 2 lines

    Precision up to 0.1 mg/LReproducibility Full-scale within 5%

    OutputRecorder output (0-5 V analog output)

    Hot output (0-5 V analog output)Printer output (Printy 3 serial thermal printer)

    Temperature controller Adjustable within 35C0.2C

    Rated power source AC 100V10V,50/60HZ,3A max

    Dimensions W370 D350 H300 mm

    Weight 14kg

    Ambient temperature 5-40C

    Ambient humidity 90% RH max (Without condensation)

    PeripheralsStandard solution, buffer solution, antibacterial tubing

    set, printer

    The Quick BODT-1 takes significant steps to do away with the weaknesses ofbiosensor BOD measuring apparatus entailed by trouble and time requiredto replace and load microbe membrane and with an exchangeableelectrode. Unit that makes it easy to use right away provides improvedoperability and maintainability standard and buffer bacteriostatic solutions

    and antibacterial tubing allow stable measurements for long terms Thededicated shipping and recovery box for Used and replacement electrodeunits may be reused any number of times and the exclusion of apparatusenvironmentally friendly and easy to use .

    BODT-1

    Application: Apply to Surface Water, Sewage, Industrial Wastewater in the BOD.

    Features:Display the trend curvePrinter outputLink to the compute through USB interfaceMercury-free devices to ensure the accuracy & safety of the BOD measurementReal-time clock displayAutomatic collection and storage of dataDepict BOD curves for the user to view

    Link to the computer to print curvesNo parameter and data loss after sudden cut-offLCD humanization interface display, easy operation1-30days of the test time, setting by the keysStore data and update the result, observe the change rate of BOD in the

    LCD screen during any testing time, store 240 data points and 20 groupsdata of each sample.

    BODT-5, BOD Tester

    Model BODT-5

    Measurableliquid containing soluble organic matter, such as

    drainage and river water

    Range0-35, 0-70, 0-350, 0-700mg/L (without dilution)

    700-4000 mg/L (need to dilute)

    Sample Quantity 6 Bottle Capacity: 500mL

    Repeatability 5%

    Resolution0.1mg/L (0-35, 0-70mg/L)

    1mg/L (0-350mg/L, 0- 700mg/L)Dimension 350 400 350mm

    Display LED

    Power Supply AC 220 50Hz

    BODT-5

    Principle of Operation:The instrument is designed by thepressure-difference method, simulatingthe degradation of natural organicmatter. 21% of the oxygen in the air onthe top of Test Bottle continuouslyreplenish the dissolved oxygenconsumed in water, carbon dioxide(CO2) produced in the process of

    organic matter degradation is absorbedby Sodium hydroxide coming from sealedcap, pressure sensor monitor constantlythe pressure change of sample bottle.There is a correlation between

    Measurements in regions of low concentration are especially stable.Changing pump rpm or sample contact time allows measurements in regions of high concentration.The optional microbe fixation kit enables the use of other microbes and, therefore, a variety of water samples.Making no use of dangerous reagents and emitting no harmful effluents, the Quick BODT-1 is environmentally friendly.

    Biochemical oxygen demand BOD (correspond to the consumption of oxygen in the test bottle) & Gas pressure, suchrelevance is dealt with by this instrument, direct display of Biochemical oxygen demand BOD value on the screen.

    MRC.5.11.13