GENERAL NOTES: 1. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE ARCHITECTURAL, CIVIL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS, AND THE SPECIFICATIONS. THE CONTRACTOR SHALL VERIFY THE REQUIREMENTS OF OTHER TRADES AS TO SLEEVES, CHASES, HANGERS, INSERTS, ANCHORS, HOLES, AND ADDITIONAL ITEMS TO BE PLACED OR SET IN THE STRUCTURAL WORK. 2. THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE PROVISIONS OF THE VIRGINIA CONSTRUCTION CODE, 2012 EDITION. 3. THE WORK OUTLINED IN SPECIFICATION SECTION 014100 IS SUBJECT TO SPECIAL INSPECTIONS AS DESCRIBED IN THE TECHNICAL SPECIFICATIONS. 4. THE CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND BRACING REQUIRED TO ERECT AND HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL PERMANENT SUPPORTS AND LATERAL BRACING ARE IN PLACE. 5. PORTIONS OF THE STRUCTURE NOT ALTERED AND NOT AFFECTED BY THE ALTERATION HAVE NOT BEEN REVIEWED FOR COMPLIANCE WITH THE CODE REQUIREMENTS FOR A NEW STRUCTURE. 6. BEFORE PROCEEDING WITH WORK WITHIN THE EXISTING STRUCTURE, THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE EXISTING STRUCTURAL CONDITIONS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE DESIGN AND ERECTION OF ANY AND ALL SAFEGUARDS NECESSARY TO PROTECT THE EXISTING STRUCTURE. 7. THE CONTRACTOR SHALL FIELD VERIFY THE DIMENSIONS, ELEVATIONS, AND OTHER REQUIREMENTS NECESSARY FOR THE PROPER CONSTRUCTION AND ALIGNMENT OF THE NEW PORTIONS OF THE STRUCTURE TO THE EXISTING. ANY DIMENSIONS SHOWN OF EXISTING STRUCTURES SHALL BE CONSIDERED AS APPROXIMATE AND ADEQUATE FOR BIDDING PURPOSES ONLY. THE CONTRACTOR SHALL MAKE ALL MEASUREMENTS NECESSARY FOR THE FABRICATION AND ERECTION OF STRUCTURAL MEMBERS. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. 8. DESIGN CRITERIA: ROOF AT MECHANICAL ROOMS 40 PSF ROOF 20 PSF SLAB ON GRADE LIVE LOADS - UNIFORM: 100 PSF 10.1 KIPS 32.3 KIPS -35 PSF/+26 PSF -72 PSF/+12 PSF III B 1.25 0.093 0.099 0.048 0.077 D INTERMEDIATE REINFORCED MASONRY SHEAR WALLS 3.5 0.035 22.7 KIPS ±0.18 98 MPH 126 MPH LIVE LOADS - CONCENTRATED: ROOFS 300# UNLESS OTHERWISE NOTED, CONCENTRATED LOADS ARE APPLIED UNIFORMLY OVER 2'-6" x 2'-6" AREA. 1.0 1.10 11 PSF 10 PSF GROUND SNOW LOAD SNOW LOADS: FLAT ROOF LOAD IMPORTANCE FACTOR (Is) THERMAL FACTOR (Ct) EXPOSURE FACTOR (Ce) ULTIMATE DESIGN WIND SPEED (V ) WIND LOADS: NOMINAL DESIGN WIND SPEED (V ) INTERNAL PRESSURE COEFFICIENT ROOF, ZONE 3 (10 SF) WALLS, ZONE 5 (10 SF) COMPONENT AND CLADDING PRESSURES: V V WIND BASE SHEARS (FOR MWFRS): ANALYSIS PROCEDURE: SPECTRAL RESPONSE ACCELERATIONS: S S SITE CLASSIFICATION SEISMIC LOADS: S 1 S DS S D1 SEISMIC DESIGN CATEGORY IMPORTANCE FACTOR (I ) BASIC STRUCTURAL SYSTEM: RESPONSE MODIFICATION COEFFICIENT (R) SEISMIC RESPONSE COEFFICIENT (Cs) SEISMIC BASE SHEAR (V) LATERAL DESIGN CONTROL CONTROLLING LATERAL LOADS: RISK CATEGORY CLASSIFICATION OF BUILDING EQUIVALENT LATERAL FORCE B EXPOSURE CATEGORY 0.90 DRIFT SURCHARGE (Pd) REF TABLE W 18 PSF 27.5 PSF 1 Pd W 2 0 PSF Pd # DRIFT VALUES SNOW DRIFT SCHEDULE 5 FT 7.5 FT NOTE: SNOW DRIFT LOADS ARE IN ADDITION TO FLAT ROOF LOADS. E ULT E-W N-S ASD 0.149 0.115 S MS S M1 SEISMIC WIND EAST-WEST NORTH-SOUTH 15 PSF 3 5 FT 7 PSF 4 3 FT 1. FOUNDATIONS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE RECOMMENDATIONS IN THE REPORT OF SUBSURFACE EXPLORATION AND GEOTECHNICAL ENGINEERING SERVICES PREPARED BY GET SOLUTIONS, INC., DATED AUGUST 23, 2017. 2. FOUNDATIONS HAVE BEEN DESIGNED FOR A NET ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PSF 3. PRIOR TO PLACING FOUNDATION CONCRETE, ALL FOUNDATION EXCAVATIONS SHALL BE INSPECTED BY THE SPECIAL INSPECTOR TO EXPLORE THE EXTENT OF LOOSE, SOFT, EXPANSIVE, OR OTHERWISE UNSATISFACTORY SOIL MATERIAL AND TO VERIFY DESIGN BEARING PRESSURE. DIRECTION FOR CORRECTIVE ACTION WILL BE PROVIDED WHERE REQUIRED. 4. NO UNBALANCED BACKFILLING SHALL BE DONE AGAINST MASONRY UNLESS WALLS ARE SECURELY BRACED AGAINST OVERTURNING, EITHER BY TEMPORARY CONSTRUCTION BRACING OR BY PERMANENT CONSTRUCTION. 5. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONTROL OF GROUNDWATER AND SURFACE RUNOFF THROUGHOUT THE CONSTRUCTION PROCESS. INUNDATION AND LONG TERM EXPOSURE OF BEARING SURFACES WHICH RESULT IN DETERIORATION OF BEARING SHALL BE PREVENTED. 6. FOLLOWING SUBGRADE 3- FOUR FOOT DEEP TEST PITS SHALL BE EXCAVATED WITHIN THE PROPOSED CONSTRUCTION UNDER THE OBSERVATION OF THE SPECIAL INSPECTOR TO EVALUATE THE EXISTING SOILS. DIRECTIVE FOR CORRECTIVE ACTION FOR UNSUITABLE SOILS WILL BE PROVIDED WHERE REQUIRED. FOUNDATION NOTES: 1. CONCRETE SHALL BE IN ACCORDANCE WITH AMERICAN CONCRETE INSTITUTE (ACI) 301 AND 318. 2. CONCRETE SHALL BE NORMAL WEIGHT AND SHALL OBTAIN A 28 DAY COMPRESSIVE STRENGTHS AS NOTED: SLAB-ON-GRADE................................................................3,500 PSI FOOTINGS...........................................................................3,000 PSI 3. REINFORCING MATERIALS SHALL BE AS FOLLOWS: A. REINFORCING BARS - ASTM A 615, GRADE 60, DEFORMED. B. WELDED WIRE REINFORCEMENT - ASTM A 185, WELDED STEEL WIRE REINFORCEMENT; PROVIDE SHEET TYPE, ROLL TYPE IS NOT ACCEPTABLE. 4. ALL REINFORCING STEEL AND EMBEDDED ITEMS SUCH AS ANCHOR RODS AND WELD PLATES SHALL BE ACCURATELY PLACED AND ADEQUATELY TIED AND SUPPORTED BEFORE CONCRETE IS PLACED TO PREVENT DISPLACEMENT BEYOND PERMITTED TOLERANCES. 5. CONCRETE COVER TO REINFORCING STEEL SHALL CONFORM TO THE MINIMUM COVER RECOMMENDATIONS IN ACI 318, UNLESS THE DRAWINGS SHOW GREATER COVER REQUIREMENTS. 6. LAP CONTINUOUS REINFORCING STEEL 57 X BAR DIAMETER, TYPICAL UNLESS OTHERWISE NOTED. CAST-IN-PLACE CONCRETE NOTES: 1. CONCRETE MASONRY MATERIALS AND CONSTRUCTION SHALL CONFORM TO THE AMERICAN CONCRETE INSTITUTE (ACI) 530. 2. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C 90 AND SHALL BE MADE WITH LIGHTWEIGHT AGGREGATE. MINIMUM NET AREA COMPRESSIVE STRENGTH OF MASONRY UNITS SHALL BE 2,800 PSI AT 28 DAYS. 3. COMPRESSIVE STRENGTH OF MASONRY SHALL BE DETERMINED BY THE UNIT STRENGTH METHOD AS SET FORTH IN ACI 530.1. THE NET AREA COMPRESSIVE STRENGTH OF MASONRY, f'm, SHALL BE 2,000 PSI AT 28 DAYS. 4. MORTAR SHALL BE TYPE M OR S AND SHALL COMPLY WITH ASTM C270, PROPORTIONS OR PROPERTIES SPECIFICATION. 5. GROUT SHALL COMPLY WITH ASTM C 476 PROPERTIES SPECIFICATION, AND SHALL BE PROPORTIONED TO OBTAIN A DOCUMENTED 28 DAY COMPRESSIVE STRENGTH OF 2,000 PSI. 6. REINFORCING STEEL SHALL COMPLY WITH ASTM A 615, GRADE 60. SHOP FABRICATE REINFORCING BARS WHICH ARE SHOWN TO BE BENT OR HOOKED. 7. ALL BOND BEAMS, REINFORCED CELLS AND CELLS WITH EXPANSION BOLTS, EMBED PLATES OR OTHER ANCHORS AND ALL CELLS BELOW GRADE SHALL BE GROUTED SOLID. GROUT PROCEDURE SHALL COMPLY WITH ACI 530.1. 8. PROVIDE REINFORCING BARS OF THE GIVEN SIZE AND SPACING SHOWN. LAP CONTINUOUS REINFORCING STEEL 72 BAR DIAMETERS UNLESS OTHERWISE NOTED. 9. ALL NON-BEARING MASONRY WALLS SHALL BE REINFORCED WITH #4 VERTICAL BARS AT 48 INCHES ON CENTER, TYPICAL UNLESS OTHERWISE NOTED. ALL NON-BEARING MASONRY WALLS SHALL BE BRACED PER "TYPICAL NON- BEARING MASONRY PARTITION DETAILS". 10. PROVIDE REINFORCING STEEL DOWELS OF THE SAME SIZE AND SPACING AS VERTICAL REINFORCING FROM THE SUPPORTING STRUCTURE. DOWELS SHALL HAVE STANDARD ACI HOOKS. LAP LENGTH FOR DOWELS FROM FOUNDATION NOT OTHERWISE NOTED MAY BE 36 X BAR DIAMETER. 11. PROVIDE STANDARD 9 GAGE LADDER TYPE HORIZONTAL JOINT REINFORCING IN CMU WALLS AT 16 INCHES ON CENTER AND IN TWO JOINTS IMMEDIATELY ABOVE AND BELOW ALL OPENINGS, EXTENDING A MINIMUM OF 2 FEET BEYOND THE JAMB ON EACH SIDE OF THE OPENING, EXCEPT AT CONTROL JOINTS. 12. PROVIDE HORIZONTAL BOND BEAMS WITH CONTINUOUS REINFORCING AS SHOWN IN THE SECTIONS AND DETAILS. DISCONTINUE ALL HORIZONTAL REINFORCING AT CONTROL JOINTS EXCEPT FOR THE BOND BEAMS AT JOIST BEARING ELEVATIONS. 13. DO NOT LOCATE CONTROL JOINTS WITHIN TWO FEET OF STEEL BEAM BEARING LOCATIONS. CONCRETE MASONRY NOTES: 1. STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) 360. 2. STRUCTURAL STEEL SHALL COMPLY WITH THE FOLLOWING SPECIFICATIONS: A. STRUCTURAL STEEL SHAPES, PLATES AND BARS (EXCEPT W-SHAPES) - ASTM A 36, Fy = 36 KSI B. STRUCTURAL STEEL W-SHAPES - ASTM A 992/A572, GRADE 50, Fy = 50 KSI C. ANCHOR RODS - ASTM F 1554, GRADE 36 D. HIGH STRENGTH BOLTS - ASTM A325 (TYPICAL UON) E. WASHERS - ASTM F 436 F. NUTS - ASTM A 563 3. UNLESS OTHERWISE NOTED, BEAM CONNECTIONS SHALL BE AISC "SIMPLE SHEAR BEAM CONNECTIONS" WITH ASTM A 325 BOLTS, DESIGNED FOR ONE- HALF THE UNIFORM LOAD CONSTANTS FOR LATERALLY SUPPORTED BEAMS GIVEN IN PART 3 OF THE "STEEL CONSTRUCTION MANUAL". 4. HIGH STRENGTH BOLTS MAY BE TIGHTENED TO THE "SNUG TIGHT" CONDITION IN LIEU OF FULL PRETENSIONING EXCEPT FOR BOLTED CONNECTIONS USING NON-STANDARD HOLES WHICH SHALL BE FULLY PRETENSIONED. 5. PROVIDE L3x3x1/4 ANGLE FRAMING AROUND OPENINGS LARGER THAN 12 INCHES IN ANY DIMENSION (INCLUDING ROOF DRAINS) TO SUPPORT STEEL DECK, TYPICAL UNLESS OTHERWISE NOTED OR DETAILED. 6. WELDING SHALL BE IN ACCORDANCE WITH AWS D1.1, "STRUCTURAL WELDING CODE - STEEL." WELD ELECTRODES SHALL BE E70XX LOW HYDROGEN. UNLESS OTHERWISE NOTED, PROVIDE CONTINUOUS FILLET WELDS WITH MINIMUM SIZE REQUIRED BY TABLE J2.4 AISC 360. 7. COORDINATE ALL MEMBER LOCATIONS, UNIT WEIGHTS, OPENING SIZES, AND CURB DIMENSIONS FOR MECHANICAL EQUIPMENT WITH THE ACTUAL EQUIPMENT FURNISHED. 8. STRUCTURAL STEEL SCHEDULED TO RECEIVE SPRAYED-ON FIREPROOFING SHALL NOT BE PRIME PAINTED. 9. HOT DIP GALVANIZE AFTER FABRICATION THE FOLLOWING: A. ANGLES AND PLATES SUPPORTING MASONRY IN EXTERIOR WALLS. B. LINTELS AND LINTEL ASSEMBLIES SUPPORTING MASONRY IN EXTERIOR WALLS. C. ALL STEEL EXPOSED TO WEATHER IN THE FINAL CONSTRUCTION. D. ITEMS IDENTIFIED AS GALVANIZED ON ARCHITECTURAL OR STRUCTURAL DRAWINGS. STRUCTURAL STEEL NOTES: 1. STEEL JOISTS SHALL BE IN ACCORDANCE WITH THE STEEL JOIST INSTITUTE (SJI) STANDARD SPECIFICATIONS. 2. JOIST BRIDGING SHALL CONFORM TO SJI SPECIFICATIONS, INCLUDING BRIDGING REQUIRED FOR JOISTS SUBJECTED TO UPLIFT LOADS. PROVIDE CROSS- BRIDGING AT ENDS OF BRIDGING LINES AND CHANGES IN JOIST DEPTHS AND AT ROLLED STEEL SHAPES RUNNING PARALLEL TO JOISTS. BRIDGING SHOWN SHALL BE PROVIDED, IN ADDITION TO THE REQUIRED STANDARD BRIDGING. ENDS OF ALL BRIDGING LINES SHALL BE ANCHORED TO WALLS OR BEAMS. 3. ROOF JOISTS SHALL BE DESIGNED FOR A NET UPLIFT LOAD OF 20 PSF. 4. ALL JOISTS SHALL BE DESIGNED FOR A CONCENTRATED LOAD OF 300 LBS. HUNG FROM THE JOIST TOP OR BOTTOM CHORD AT ANY POINT ALONG THE SPAN. 5. STEEL JOISTS SCHEDULED TO RECEIVE SPRAYED-ON FIREPROOFING SHALL NOT BE PRIME PAINTED. 6. PERMANENT SUSPENDED LOADS SHALL NOT BE SUPPORTED BY JOIST BRIDGING. 7. SUBMIT SPRINKLER SHOP DRAWINGS INCLUDING LOADS AND LOCATIONS PRIOR TO FABRICATION OF JOISTS. 8. COMPLY WITH OSHA SAFETY STANDARDS FOR THE ERECTION OF STEEL JOISTS. STEEL JOIST NOTES: 1. STEEL DECK SHALL BE IN ACCORDANCE WITH THE AMERICAN IRON AND STEEL INSTITUTE (AISI), "NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD- FORMED STEEL STRUCTURAL MEMBERS" AND THE STEEL DECK INSTITUTE (SDI), "DESIGN MANUAL FOR COMPOSITE DECKS, FORM DECKS, AND ROOF DECKS." 2. STEEL DECK INSTALLATION SHALL COMPLY WITH THE FOLLOWING: A. ROOF DECK: 1 1/2" X 22 GAGE TYPE B GALVANIZED. UNLESS OTHERWISE NOTED, ATTACH DECK TO SUPPORTS WITH 5/8 INCH DIAMETER PUDDLE WELDS IN ALL RIBS WHERE END LAPS OCCUR AND AT 12 INCHES ON CENTER ALONG SUPPORTS WITH A 36/4 PATTERN. FASTEN SIDE LAPS WITH #10 SELF-TAPPING HEX HEAD SCREWS AT 1/3 POINTS BETWEEN SUPPORTS. FASTEN EDGEMOST DECK PANEL TO STEEL FRAMING WITH 5/8 INCH DIAMETER PUDDLE WELDS AT SAME SPACING AS SIDELAP FASTENERS. 3. STEEL DECK SHALL BE INSTALLED PERPENDICULAR TO SUPPORTS AND SHALL HAVE A MINIMUM OF THREE CONTINUOUS SPANS. ENDLAPS SHALL ONLY OCCUR AT SUPPORTS. 4. WELDING SHALL BE IN ACCORDANCE WITH AWS D1.3 "STRUCTURAL WELDING CODE - SHEET STEEL". 5. PERMANENT SUSPENDED LOADS SHALL NOT BE SUPPORTED BY STEEL ROOF DECK. STEEL DECK NOTES: RTU-X = JOIST BEARING ELEVATION MEASURED FROM REFERENCED FINISHED FIRST FLOOR ELEVATION = 0'-0" = MECHANICAL UNIT SUPPORTED ABOVE FRAMING (WEIGHT IN POUNDS) - COORDINATE W/ MECH DWGS = FLOOR / ROOF OPENING = TOP OF FOOTING ELEVATION MEASURED FROM REFERENCED FINISHED FIRST FLOOR ELEVATION = 0'-0" (-X'-X") = CHANGE IN ELEVATION - REF ARCH DWGS FOR DIMENSIONS = DIRECTION OF SLOPE KCJ, CJ, OR SJ LINE ON PLAN = WARP LINE OF ROOF DECK = PLAN KEY NOTE MARK = X SX SECTION/DETAIL MARK = SECTION/DETAIL NUMBER/LETTER SHEET NUMBER WHERE SECTION/DETAIL MARK IS DRAWN WALL FOOTING MARK = WFX FIELD VERIFY = ± PLAN LEGEND: SL X JBE = +X'-X" PIPE CROSSING FOOTING = SF SF = TOP OF EXISTING FOOTING ELEVATION MEASURED FROM REFERENCED FINISHED FIRST FLOOR ELEVATION = 0'-0" <-X'-X"±> AFF ARCH BD BEJ BLDG BOD BOT, B BRG BTWN C TO C CFMF CJ CL CLR CMU COL CONC CONN CONSTR CONT COORD CTR CTRD CW DBL DCJ DIA DJ DWGS EA EF EJ EL ELEV EMBED EOD EOS EQ EW EXIST EXP EXT FD FDN FO FF EL FIN FIN FLR FOB FOC FOM FOS FRMG FTG FV GALV GEN GR BM H HK HORIZ ABOVE FINISHED FLOOR ARCHITECT BAR DIAMETER BUILDING EXPANSION JOINT BUILDING BOTTOM OF DECK BOTTOM BEARING BETWEEN CENTER TO CENTER COLD FORMED METAL FRAMIN CONTROL JOINT CENTERLINE CLEAR CONCRETE MASONRY UNIT COLUMN CONCRETE CONNECTION CONSTRUCTION CONTINUOUS COORDINATE CENTER CENTERED CURTAIN WALL DOUBLE DOWELED CONSTRUCTION JOINT DIAMETER DOUBLE JOIST DRAWINGS EACH EACH FACE EXPANSION JOINT ELEVATION ELEVATOR EMBEDMENT EDGE OF DECK EDGE OF SLAB EQUAL EACH WAY EXISTING EXPANSION EXTERIOR FLOOR DRAIN FOUNDATION FACE OF FINISHED FLOOR ELEVATION FINISH FINISHED FLOOR FACE OF BUILDING FACE OF CONCRETE FACE OF MASONRY FACE OF SLAB/ STUD FRAMING FOOTING FIELD VERIFY GALVANIZED GENERAL GRADE BEAM HIGH HOOK HORIZONTAL HSS HT HVY INT JBE JT KCJ L LLH LLV LSH LSV LTWT LWC MAS MATL MAX MECH MFR MID MIN MOD MOS NOM NTS OC OPH OPNG PAF PAR PC PEN PERP PL R REF REINF REQD REQMTS SCHED SF SGB SIM SJ SL T&B T&G THK TOC TOF TOM TOS TS TYP UON VERT W/ WP WSP WWR HOLLOW STRUCTURAL SECTIONS HEIGHT HEAVY INTERIOR JOIST BEARING ELEVATION JOINT KEYED CONSTRUCTION JOINT LOW LONG LEG HORIZONTAL LONG LEG VERTICAL LONG SIDE HORIZONTAL LONG SIDE VERTICAL LIGHTWEIGHT LIGHTWEIGHT CONCRETE MASONRY MATERIAL MAXIMUM MECHANICAL MANUFACTURER MIDDLE MINIMUM MODIFY MIDDEPTH OF SLAB NOMINAL NOT TO SCALE ON CENTER OPPOSITE HAND OPENING POWDER ACTUATED FASTENER PARALLEL PIECE PENETRATE, PENETRATION PERPENDICULAR PLATE RADIUS REFERENCE, REFER TO REINFORCE, REINFORCED, REINFORCING REQUIRED REQUIREMENTS SCHEDULE STEPPED FOOTING STEPPED GRADE BEAM SIMILAR SAWED JOINT SLOPE TOP AND BOTTOM TONGUE AND GROOVE THICKNESS TOP OF CONCRETE TOP OF FOOTING TOP OF MASONRY TOP OF STEEL THICKENED SLAB TYPICAL UNLESS OTHERWISE NOTED VERTICAL WITH WORKING POINT WOOD STRUCTURAL PANEL(S) WELDED WIRE REINFORCING ABBREVIATIONS: Structural Engineers 5032 Rouse Dr., Ste 200 Virginia Beach, VA 23462 757.671.8626 - lynchmykins.com A B C E F 1 2 3 4 5 6 1 2 3 4 5 6 1/32"=1'-0" 1/16"=1'-0" 3/32"=1'-0" 1/8"=1'-0" 1/4"=1'-0" 3/8"=1'-0" 1/2"=1'-0" 3/4"=1'-0" 1"=1'-0" 1 1/2"=1'-0" 3"=1'-0" 0 6" 5" 4" 3" 2" 1" 3" 6" 9" 1' 0 SHEET NUMBER 1909 CYPRESS AVENUE VIRGINIA BEACH, VA 23451 (757) 417 - 0140 0 3" 6" 9" 1' 1.5" 0 6" 1' 2' 0 6" 1' 2' 3' 0 1' 2' 3' 4' 0 2' 4' 6' 0 4' 8' 12' 0 4' 8' 16' 0 4' 8' 16' 24' 0 16' 32' 48' SHEET TITLE PROJECT NO DATE REVISIONS PROJ MGR CHECKED DESIGNED DRAWN 7 8 6"=1'-0" 0 3" 2" 1" 12"=1'-0" 0 1.5" 1" 1' 7 8 D LM Project # V17.048 FOR PERMIT REVIEW 11-2-17 1 11−22−17 D:\Work\Projects\01 - Revit Local Files\V17048_BMW Addition_Struct_ [email protected] 11/20/2017 2:22:35 PM S001 B.M. WILLIAMS PRIMARY SCHOOL ADDITION GENERAL NOTES CS TDC JDT 1716 11.22.17 CHESAPEAKE VIRGINIA MSM SYMBOL DESCRIPTION DATE

B.M. WILLIAMS PRIMARY SCHOOL ADDITION · reinforcing steel shall comply with astm a 615, ... astm f 1554, grade 36 ... welding shall be in accordance with aws d1.3 "structural welding

Embed Size (px)

Citation preview

GENERAL NOTES:

1. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE ARCHITECTURAL, CIVIL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS, AND THE SPECIFICATIONS. THE CONTRACTOR SHALL VERIFY THE REQUIREMENTS OF OTHER TRADES AS TO SLEEVES, CHASES, HANGERS, INSERTS, ANCHORS, HOLES, AND ADDITIONAL ITEMS TO BE PLACED OR SET IN THE STRUCTURAL WORK.

2. THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE PROVISIONS OF THE VIRGINIA CONSTRUCTION CODE, 2012 EDITION.

3. THE WORK OUTLINED IN SPECIFICATION SECTION 014100 IS SUBJECT TO SPECIAL INSPECTIONS AS DESCRIBED IN THE TECHNICAL SPECIFICATIONS.

4. THE CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND BRACING REQUIRED TO ERECT AND HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL PERMANENT SUPPORTS AND LATERAL BRACING ARE IN PLACE.

5. PORTIONS OF THE STRUCTURE NOT ALTERED AND NOT AFFECTED BY THE ALTERATION HAVE NOT BEEN REVIEWED FOR COMPLIANCE WITH THE CODE REQUIREMENTS FOR A NEW STRUCTURE.

6. BEFORE PROCEEDING WITH WORK WITHIN THE EXISTING STRUCTURE, THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE EXISTING STRUCTURAL CONDITIONS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE DESIGN AND ERECTION OF ANY AND ALL SAFEGUARDS NECESSARY TO PROTECT THE EXISTING STRUCTURE.

7. THE CONTRACTOR SHALL FIELD VERIFY THE DIMENSIONS, ELEVATIONS, AND OTHER REQUIREMENTS NECESSARY FOR THE PROPER CONSTRUCTION AND ALIGNMENT OF THE NEW PORTIONS OF THE STRUCTURE TO THE EXISTING. ANY DIMENSIONS SHOWN OF EXISTING STRUCTURES SHALL BE CONSIDERED AS APPROXIMATE AND ADEQUATE FOR BIDDING PURPOSES ONLY. THE CONTRACTOR SHALL MAKE ALL MEASUREMENTS NECESSARY FOR THE FABRICATION AND ERECTION OF STRUCTURAL MEMBERS. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT.

8. DESIGN CRITERIA:

ROOF AT MECHANICAL ROOMS 40 PSFROOF 20 PSFSLAB ON GRADE

LIVE LOADS - UNIFORM:100 PSF

10.1 KIPS32.3 KIPS

-35 PSF/+26 PSF

-72 PSF/+12 PSF

III

B1.25

0.093

0.099

0.048

0.077

D

INTERMEDIATE REINFORCEDMASONRY SHEAR WALLS

3.50.035

22.7 KIPS

±0.18

98 MPH126 MPH

LIVE LOADS - CONCENTRATED:

ROOFS 300#

UNLESS OTHERWISE NOTED, CONCENTRATED LOADS ARE APPLIED UNIFORMLY OVER 2'-6" x 2'-6" AREA.

1.01.10

11 PSF 10 PSFGROUND SNOW LOAD

SNOW LOADS:

FLAT ROOF LOADIMPORTANCE FACTOR (Is)THERMAL FACTOR (Ct)EXPOSURE FACTOR (Ce)

ULTIMATE DESIGN WIND SPEED (V )WIND LOADS:

NOMINAL DESIGN WIND SPEED (V )

INTERNAL PRESSURE COEFFICIENT

ROOF, ZONE 3 (10 SF)

WALLS, ZONE 5 (10 SF)COMPONENT AND CLADDING PRESSURES:

V V

WIND BASE SHEARS (FOR MWFRS):

ANALYSIS PROCEDURE:

SPECTRAL RESPONSE ACCELERATIONS:

SS

SITE CLASSIFICATIONSEISMIC LOADS:

S1

SDS SD1

SEISMIC DESIGN CATEGORYIMPORTANCE FACTOR (I )

BASIC STRUCTURAL SYSTEM:

RESPONSE MODIFICATION COEFFICIENT (R)SEISMIC RESPONSE COEFFICIENT (Cs)SEISMIC BASE SHEAR (V)

LATERAL DESIGN CONTROLCONTROLLING LATERAL LOADS:

RISK CATEGORY

CLASSIFICATION OF BUILDING

EQUIVALENT LATERAL FORCE

BEXPOSURE CATEGORY

0.90DRIFT SURCHARGE (Pd) REF TABLE

W

18 PSF

27.5 PSF

1

PdW

2

0 PSF

Pd#

DRIFT VALUES

SNOW DRIFT SCHEDULE

5 FT

7.5 FT

NOTE: SNOW DRIFT LOADS ARE IN ADDITION TO FLAT ROOF LOADS.

E

ULT

E-W

N-S

ASD

0.149 0.115SMS SM1

SEISMICWIND

EAST-WESTNORTH-SOUTH

15 PSF3 5 FT

7 PSF4 3 FT

1. FOUNDATIONS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE RECOMMENDATIONS IN THE REPORT OF SUBSURFACE EXPLORATION AND GEOTECHNICAL ENGINEERING SERVICES PREPARED BY GET SOLUTIONS, INC., DATED AUGUST 23, 2017.

2. FOUNDATIONS HAVE BEEN DESIGNED FOR A NET ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PSF

3. PRIOR TO PLACING FOUNDATION CONCRETE, ALL FOUNDATION EXCAVATIONS SHALL BE INSPECTED BY THE SPECIAL INSPECTOR TO EXPLORE THE EXTENT OF LOOSE, SOFT, EXPANSIVE, OR OTHERWISE UNSATISFACTORY SOIL MATERIAL AND TO VERIFY DESIGN BEARING PRESSURE. DIRECTION FOR CORRECTIVE ACTION WILL BE PROVIDED WHERE REQUIRED.

4. NO UNBALANCED BACKFILLING SHALL BE DONE AGAINST MASONRY UNLESS WALLS ARE SECURELY BRACED AGAINST OVERTURNING, EITHER BY TEMPORARY CONSTRUCTION BRACING OR BY PERMANENT CONSTRUCTION.

5. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONTROL OF GROUNDWATER AND SURFACE RUNOFF THROUGHOUT THE CONSTRUCTION PROCESS. INUNDATION AND LONG TERM EXPOSURE OF BEARING SURFACES WHICH RESULT IN DETERIORATION OF BEARING SHALL BE PREVENTED.

6. FOLLOWING SUBGRADE 3- FOUR FOOT DEEP TEST PITS SHALL BE EXCAVATED WITHIN THE PROPOSED CONSTRUCTION UNDER THE OBSERVATION OF THE SPECIAL INSPECTOR TO EVALUATE THE EXISTING SOILS. DIRECTIVE FOR CORRECTIVE ACTION FOR UNSUITABLE SOILS WILL BE PROVIDED WHERE REQUIRED.

FOUNDATION NOTES:

1. CONCRETE SHALL BE IN ACCORDANCE WITH AMERICAN CONCRETE INSTITUTE (ACI) 301 AND 318.

2. CONCRETE SHALL BE NORMAL WEIGHT AND SHALL OBTAIN A 28 DAY COMPRESSIVE STRENGTHS AS NOTED:

SLAB-ON-GRADE................................................................3,500 PSIFOOTINGS...........................................................................3,000 PSI

3. REINFORCING MATERIALS SHALL BE AS FOLLOWS:

A. REINFORCING BARS - ASTM A 615, GRADE 60, DEFORMED.

B. WELDED WIRE REINFORCEMENT - ASTM A 185, WELDED STEEL WIRE REINFORCEMENT; PROVIDE SHEET TYPE, ROLL TYPE IS NOT ACCEPTABLE.

4. ALL REINFORCING STEEL AND EMBEDDED ITEMS SUCH AS ANCHOR RODS AND WELD PLATES SHALL BE ACCURATELY PLACED AND ADEQUATELY TIED AND SUPPORTED BEFORE CONCRETE IS PLACED TO PREVENT DISPLACEMENT BEYOND PERMITTED TOLERANCES.

5. CONCRETE COVER TO REINFORCING STEEL SHALL CONFORM TO THE MINIMUM COVER RECOMMENDATIONS IN ACI 318, UNLESS THE DRAWINGS SHOW GREATER COVER REQUIREMENTS.

6. LAP CONTINUOUS REINFORCING STEEL 57 X BAR DIAMETER, TYPICAL UNLESS OTHERWISE NOTED.

CAST-IN-PLACE CONCRETE NOTES:

1. CONCRETE MASONRY MATERIALS AND CONSTRUCTION SHALL CONFORM TO THE AMERICAN CONCRETE INSTITUTE (ACI) 530.

2. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C 90 AND SHALL BE MADE WITH LIGHTWEIGHT AGGREGATE. MINIMUM NET AREA COMPRESSIVE STRENGTH OF MASONRY UNITS SHALL BE 2,800 PSI AT 28 DAYS.

3. COMPRESSIVE STRENGTH OF MASONRY SHALL BE DETERMINED BY THE UNIT STRENGTH METHOD AS SET FORTH IN ACI 530.1. THE NET AREA COMPRESSIVE STRENGTH OF MASONRY, f'm, SHALL BE 2,000 PSI AT 28 DAYS.

4. MORTAR SHALL BE TYPE M OR S AND SHALL COMPLY WITH ASTM C270, PROPORTIONS OR PROPERTIES SPECIFICATION.

5. GROUT SHALL COMPLY WITH ASTM C 476 PROPERTIES SPECIFICATION, AND SHALL BE PROPORTIONED TO OBTAIN A DOCUMENTED 28 DAY COMPRESSIVE STRENGTH OF 2,000 PSI.

6. REINFORCING STEEL SHALL COMPLY WITH ASTM A 615, GRADE 60. SHOP FABRICATE REINFORCING BARS WHICH ARE SHOWN TO BE BENT OR HOOKED.

7. ALL BOND BEAMS, REINFORCED CELLS AND CELLS WITH EXPANSION BOLTS, EMBED PLATES OR OTHER ANCHORS AND ALL CELLS BELOW GRADE SHALL BE GROUTED SOLID. GROUT PROCEDURE SHALL COMPLY WITH ACI 530.1.

8. PROVIDE REINFORCING BARS OF THE GIVEN SIZE AND SPACING SHOWN. LAP CONTINUOUS REINFORCING STEEL 72 BAR DIAMETERS UNLESS OTHERWISE NOTED.

9. ALL NON-BEARING MASONRY WALLS SHALL BE REINFORCED WITH #4 VERTICAL BARS AT 48 INCHES ON CENTER, TYPICAL UNLESS OTHERWISE NOTED. ALL NON-BEARING MASONRY WALLS SHALL BE BRACED PER "TYPICAL NON-BEARING MASONRY PARTITION DETAILS".

10. PROVIDE REINFORCING STEEL DOWELS OF THE SAME SIZE AND SPACING AS VERTICAL REINFORCING FROM THE SUPPORTING STRUCTURE. DOWELS SHALL HAVE STANDARD ACI HOOKS. LAP LENGTH FOR DOWELS FROM FOUNDATION NOT OTHERWISE NOTED MAY BE 36 X BAR DIAMETER.

11. PROVIDE STANDARD 9 GAGE LADDER TYPE HORIZONTAL JOINT REINFORCING IN CMU WALLS AT 16 INCHES ON CENTER AND IN TWO JOINTS IMMEDIATELY ABOVE AND BELOW ALL OPENINGS, EXTENDING A MINIMUM OF 2 FEET BEYOND THE JAMB ON EACH SIDE OF THE OPENING, EXCEPT AT CONTROL JOINTS.

12. PROVIDE HORIZONTAL BOND BEAMS WITH CONTINUOUS REINFORCING AS SHOWN IN THE SECTIONS AND DETAILS. DISCONTINUE ALL HORIZONTAL REINFORCING AT CONTROL JOINTS EXCEPT FOR THE BOND BEAMS AT JOIST BEARING ELEVATIONS.

13. DO NOT LOCATE CONTROL JOINTS WITHIN TWO FEET OF STEEL BEAM BEARING LOCATIONS.

CONCRETE MASONRY NOTES:

1. STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) 360.

2. STRUCTURAL STEEL SHALL COMPLY WITH THE FOLLOWING SPECIFICATIONS:

A. STRUCTURAL STEEL SHAPES, PLATES AND BARS (EXCEPT W-SHAPES) -ASTM A 36, Fy = 36 KSI

B. STRUCTURAL STEEL W-SHAPES - ASTM A 992/A572, GRADE 50, Fy = 50 KSI

C. ANCHOR RODS - ASTM F 1554, GRADE 36

D. HIGH STRENGTH BOLTS - ASTM A325 (TYPICAL UON)

E. WASHERS - ASTM F 436

F. NUTS - ASTM A 563

3. UNLESS OTHERWISE NOTED, BEAM CONNECTIONS SHALL BE AISC "SIMPLE SHEAR BEAM CONNECTIONS" WITH ASTM A 325 BOLTS, DESIGNED FOR ONE-HALF THE UNIFORM LOAD CONSTANTS FOR LATERALLY SUPPORTED BEAMS GIVEN IN PART 3 OF THE "STEEL CONSTRUCTION MANUAL".

4. HIGH STRENGTH BOLTS MAY BE TIGHTENED TO THE "SNUG TIGHT" CONDITION IN LIEU OF FULL PRETENSIONING EXCEPT FOR BOLTED CONNECTIONS USING NON-STANDARD HOLES WHICH SHALL BE FULLY PRETENSIONED.

5. PROVIDE L3x3x1/4 ANGLE FRAMING AROUND OPENINGS LARGER THAN 12 INCHES IN ANY DIMENSION (INCLUDING ROOF DRAINS) TO SUPPORT STEEL DECK, TYPICAL UNLESS OTHERWISE NOTED OR DETAILED.

6. WELDING SHALL BE IN ACCORDANCE WITH AWS D1.1, "STRUCTURAL WELDING CODE - STEEL." WELD ELECTRODES SHALL BE E70XX LOW HYDROGEN. UNLESS OTHERWISE NOTED, PROVIDE CONTINUOUS FILLET WELDS WITH MINIMUM SIZE REQUIRED BY TABLE J2.4 AISC 360.

7. COORDINATE ALL MEMBER LOCATIONS, UNIT WEIGHTS, OPENING SIZES, AND CURB DIMENSIONS FOR MECHANICAL EQUIPMENT WITH THE ACTUAL EQUIPMENT FURNISHED.

8. STRUCTURAL STEEL SCHEDULED TO RECEIVE SPRAYED-ON FIREPROOFING SHALL NOT BE PRIME PAINTED.

9. HOT DIP GALVANIZE AFTER FABRICATION THE FOLLOWING:

A. ANGLES AND PLATES SUPPORTING MASONRY IN EXTERIOR WALLS.

B. LINTELS AND LINTEL ASSEMBLIES SUPPORTING MASONRY IN EXTERIOR WALLS.

C. ALL STEEL EXPOSED TO WEATHER IN THE FINAL CONSTRUCTION.

D. ITEMS IDENTIFIED AS GALVANIZED ON ARCHITECTURAL OR STRUCTURAL DRAWINGS.

STRUCTURAL STEEL NOTES:

1. STEEL JOISTS SHALL BE IN ACCORDANCE WITH THE STEEL JOIST INSTITUTE (SJI) STANDARD SPECIFICATIONS.

2. JOIST BRIDGING SHALL CONFORM TO SJI SPECIFICATIONS, INCLUDING BRIDGING REQUIRED FOR JOISTS SUBJECTED TO UPLIFT LOADS. PROVIDE CROSS-BRIDGING AT ENDS OF BRIDGING LINES AND CHANGES IN JOIST DEPTHS AND AT ROLLED STEEL SHAPES RUNNING PARALLEL TO JOISTS. BRIDGING SHOWN SHALL BE PROVIDED, IN ADDITION TO THE REQUIRED STANDARD BRIDGING. ENDS OF ALL BRIDGING LINES SHALL BE ANCHORED TO WALLS OR BEAMS.

3. ROOF JOISTS SHALL BE DESIGNED FOR A NET UPLIFT LOAD OF 20 PSF.

4. ALL JOISTS SHALL BE DESIGNED FOR A CONCENTRATED LOAD OF 300 LBS. HUNG FROM THE JOIST TOP OR BOTTOM CHORD AT ANY POINT ALONG THE SPAN.

5. STEEL JOISTS SCHEDULED TO RECEIVE SPRAYED-ON FIREPROOFING SHALL NOT BE PRIME PAINTED.

6. PERMANENT SUSPENDED LOADS SHALL NOT BE SUPPORTED BY JOIST BRIDGING.

7. SUBMIT SPRINKLER SHOP DRAWINGS INCLUDING LOADS AND LOCATIONS PRIOR TO FABRICATION OF JOISTS.

8. COMPLY WITH OSHA SAFETY STANDARDS FOR THE ERECTION OF STEEL JOISTS.

STEEL JOIST NOTES:

1. STEEL DECK SHALL BE IN ACCORDANCE WITH THE AMERICAN IRON AND STEEL INSTITUTE (AISI), "NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS" AND THE STEEL DECK INSTITUTE (SDI), "DESIGN MANUAL FOR COMPOSITE DECKS, FORM DECKS, AND ROOF DECKS."

2. STEEL DECK INSTALLATION SHALL COMPLY WITH THE FOLLOWING:

A. ROOF DECK: 1 1/2" X 22 GAGE TYPE B GALVANIZED. UNLESS OTHERWISE NOTED, ATTACH DECK TO SUPPORTS WITH 5/8 INCH DIAMETER PUDDLE WELDS IN ALL RIBS WHERE END LAPS OCCUR AND AT 12 INCHES ON CENTER ALONG SUPPORTS WITH A 36/4 PATTERN. FASTEN SIDE LAPS WITH #10 SELF-TAPPING HEX HEAD SCREWS AT 1/3 POINTS BETWEEN SUPPORTS. FASTEN EDGEMOST DECK PANEL TO STEEL FRAMING WITH 5/8 INCH DIAMETER PUDDLE WELDS AT SAME SPACING AS SIDELAP FASTENERS.

3. STEEL DECK SHALL BE INSTALLED PERPENDICULAR TO SUPPORTS AND SHALL HAVE A MINIMUM OF THREE CONTINUOUS SPANS. ENDLAPS SHALL ONLY OCCUR AT SUPPORTS.

4. WELDING SHALL BE IN ACCORDANCE WITH AWS D1.3 "STRUCTURAL WELDING CODE - SHEET STEEL".

5. PERMANENT SUSPENDED LOADS SHALL NOT BE SUPPORTED BY STEEL ROOF DECK.

STEEL DECK NOTES:

RTU-X

= JOIST BEARING ELEVATION MEASUREDFROM REFERENCED FINISHED FIRSTFLOOR ELEVATION = 0'-0"

= MECHANICAL UNIT SUPPORTED ABOVEFRAMING (WEIGHT IN POUNDS) -COORDINATE W/ MECH DWGS

= FLOOR / ROOF OPENING

= TOP OF FOOTING ELEVATION MEASUREDFROM REFERENCED FINISHED FIRSTFLOOR ELEVATION = 0'-0"

(-X'-X")

= CHANGE IN ELEVATION -REF ARCH DWGS FOR DIMENSIONS

= DIRECTION OF SLOPE

KCJ, CJ, OR SJ LINE ON PLAN=

WARP LINE OF ROOF DECK=

PLAN KEY NOTE MARK=

XSX

SECTION/DETAIL MARK=

SECTION/DETAIL NUMBER/LETTER

SHEET NUMBER WHERE SECTION/DETAIL MARK IS DRAWN

WALL FOOTING MARK=WFX

FIELD VERIFY=±

PLAN LEGEND:

SL

X

JBE = +X'-X"

PIPE CROSSING FOOTING=

SFSF

= TOP OF EXISTING FOOTING ELEVATION MEASURED FROM REFERENCED FINISHED FIRSTFLOOR ELEVATION = 0'-0"

<-X'-X"±>

AFFARCHBDBEJBLDGBODBOT, BBRGBTWNC TO CCFMFCJCLCLRCMUCOLCONCCONNCONSTRCONTCOORDCTRCTRDCWDBLDCJDIADJDWGSEAEFEJELELEVEMBEDEODEOSEQEWEXISTEXPEXTFDFDNFOFF ELFINFIN FLRFOBFOCFOMFOSFRMGFTGFVGALVGENGR BMHHKHORIZ

ABOVE FINISHED FLOORARCHITECTBAR DIAMETERBUILDING EXPANSION JOINTBUILDINGBOTTOM OF DECKBOTTOMBEARINGBETWEENCENTER TO CENTERCOLD FORMED METAL FRAMINCONTROL JOINTCENTERLINECLEARCONCRETE MASONRY UNITCOLUMNCONCRETECONNECTIONCONSTRUCTIONCONTINUOUSCOORDINATECENTERCENTEREDCURTAIN WALLDOUBLEDOWELED CONSTRUCTION JOINTDIAMETERDOUBLE JOISTDRAWINGSEACHEACH FACEEXPANSION JOINTELEVATIONELEVATOREMBEDMENTEDGE OF DECKEDGE OF SLABEQUALEACH WAYEXISTINGEXPANSIONEXTERIORFLOOR DRAINFOUNDATIONFACE OFFINISHED FLOOR ELEVATIONFINISHFINISHED FLOORFACE OF BUILDINGFACE OF CONCRETEFACE OF MASONRYFACE OF SLAB/ STUDFRAMINGFOOTINGFIELD VERIFYGALVANIZEDGENERALGRADE BEAMHIGHHOOKHORIZONTAL

HSSHTHVYINTJBEJTKCJLLLHLLVLSHLSVLTWTLWCMASMATLMAXMECHMFRMIDMINMODMOSNOMNTSOCOPHOPNGPAFPARPCPENPERPPLRREFREINFREQDREQMTSSCHEDSFSGBSIMSJSLT&BT&GTHKTOCTOFTOMTOSTSTYPUONVERTW/WPWSPWWR

HOLLOW STRUCTURAL SECTIONSHEIGHTHEAVYINTERIORJOIST BEARING ELEVATIONJOINTKEYED CONSTRUCTION JOINTLOWLONG LEG HORIZONTALLONG LEG VERTICALLONG SIDE HORIZONTALLONG SIDE VERTICALLIGHTWEIGHTLIGHTWEIGHT CONCRETEMASONRYMATERIALMAXIMUMMECHANICALMANUFACTURERMIDDLEMINIMUMMODIFYMIDDEPTH OF SLABNOMINALNOT TO SCALEON CENTEROPPOSITE HANDOPENINGPOWDER ACTUATED FASTENERPARALLELPIECEPENETRATE, PENETRATIONPERPENDICULARPLATERADIUSREFERENCE, REFER TOREINFORCE, REINFORCED, REINFORCINGREQUIREDREQUIREMENTSSCHEDULESTEPPED FOOTINGSTEPPED GRADE BEAMSIMILARSAWED JOINTSLOPETOP AND BOTTOMTONGUE AND GROOVETHICKNESSTOP OF CONCRETETOP OF FOOTINGTOP OF MASONRYTOP OF STEELTHICKENED SLABTYPICALUNLESS OTHERWISE NOTEDVERTICALWITHWORKING POINTWOOD STRUCTURAL PANEL(S)WELDED WIRE REINFORCING

ABBREVIATIONS:

Structural Engineers5032 Rouse Dr., Ste 200

Virginia Beach, VA 23462

757.671.8626 - lynchmykins.com

A

B

C

E

F

1 2 3 4 5 6

1 2 3 4 5 6

1/32"=1'-0" 1/16"=1'-0" 3/32"=1'-0" 1/8"=1'-0" 1/4"=1'-0" 3/8"=1'-0" 1/2"=1'-0" 3/4"=1'-0" 1"=1'-0" 1 1/2"=1'-0" 3"=1'-0"0 6"5"4"3"2"1"3" 6" 9"1'0

SHEET NUMBER

1909 CYPRESS AVENUEVIRGINIA BEACH, VA 23451

(757) 417 - 0140

0 3" 6" 9" 1' 1.5"0 6" 1' 2'0 6" 1' 2' 3'0 1' 2' 3' 4'0 2' 4' 6'0 4' 8' 12'0 4' 8' 16'0 4' 8' 16' 24'0 16' 32' 48'

SH

EE

T T

ITLE

PR

OJE

CT

NO

DA

TE

RE

VIS

ION

S

PR

OJ

MG

R

CH

EC

KE

D

DE

SIG

NE

D

DR

AW

N

7 8

6"=1'-0"0 3"2"1"

12"=1'-0"0 1.5"1"1'

7 8

D

LM Project # V17.048

FO

R P

ER

MIT

RE

VIE

W11

-2-1

71

11−22−17

D:\W

ork\

Pro

ject

s\01

- R

evit

Loca

l File

s\V

1704

8_B

MW

Add

ition

_Stru

ct_

R17

_tde

lacr

uz@

lync

hmyk

ins.

com

.com

.rvt

11/2

0/20

17 2

:22:

35 P

M

S001

B.M

. W

ILLIA

MS

PR

IMA

RY

SC

HO

OL A

DD

ITIO

N

GE

NE

RA

L N

OT

ES

CS

TD

C

JDT

1716

11.2

2.17

CH

ES

AP

EA

KE

VIR

GIN

IA

MS

MS

YM

BO

LD

ES

CR

IPT

ION

DA

TE

6'-0" ±202'-0"

2"

BE

J5

4'-0"

50'-8 3/4"43'-4"23'-4"34'-3"21'-11"

93'-8" ±

15

'-1"

±

1'-4"

21'-8

1/2

" 3

7'-4"

1'-4"

19'-8" ±

16'-0"

2"

BE

J

TS

.KC

J

TS (TYP UON)

WF2 (TYP UON)

WF3

WF

3

1

S301_________

S301_________

5

S301_________

1

S301_________

1

S301_________1

S301_________

TS

/KC

J

TS

/KC

J

S1

< -1'

-4" ±>

< -2'-0

" ±>

< -2'-0

" ±>

< -1'-4" ±>

TYP

S2

N1

2

S301_________

62'-1"

S3

N2N2

S3

S301_________

S301_________

3

S301_________

WF3.5S502

B

S502A

S502C

S502D

4A

S301_________4C 4B

4A

2" BEJ25'-4"46'-0"22'-0"2" BEJ

1

S301_________

1

S301_________SIM

TO

( -1

'-4"

)

SFSF

SF

SFSF

( -1'-4" )

SF

SF( -

2'-0

" )

( -2

'-0" )

SFSFSFSF

( -2

'-0" )

SFSF

N1 N1

SFSF

N1

( -2'-0

" )

( -2'-0" )( -2'-0

" ) N1

N1

( -2'-0

" )

SFSFSFSF

WF3

N1

N1

SFSF

( -2

'-0" )

( -2

'-0" )

( -2'-0

" )

N1

SF SF

( -2

'-0"

)

Structural Engineers5032 Rouse Dr., Ste 200

Virginia Beach, VA 23462

757.671.8626 - lynchmykins.com

A

B

C

E

F

1 2 3 4 5 6

1 2 3 4 5 6

1/32"=1'-0" 1/16"=1'-0" 3/32"=1'-0" 1/8"=1'-0" 1/4"=1'-0" 3/8"=1'-0" 1/2"=1'-0" 3/4"=1'-0" 1"=1'-0" 1 1/2"=1'-0" 3"=1'-0"0 6"5"4"3"2"1"3" 6" 9"1'0

SHEET NUMBER

1909 CYPRESS AVENUEVIRGINIA BEACH, VA 23451

(757) 417 - 0140

0 3" 6" 9" 1' 1.5"0 6" 1' 2'0 6" 1' 2' 3'0 1' 2' 3' 4'0 2' 4' 6'0 4' 8' 12'0 4' 8' 16'0 4' 8' 16' 24'0 16' 32' 48'

SH

EE

T T

ITLE

PR

OJE

CT

NO

DA

TE

RE

VIS

ION

S

PR

OJ

MG

R

CH

EC

KE

D

DE

SIG

NE

D

DR

AW

N

7 8

6"=1'-0"0 3"2"1"

12"=1'-0"0 1.5"1"1'

7 8

D

LM Project # V17.048

FO

R P

ER

MIT

RE

VIE

W11

-2-1

71

11−22−17

D:\W

ork\

Pro

ject

s\01

- R

evit

Loca

l File

s\V

1704

8_B

MW

Add

ition

_Stru

ct_

R17

_tde

lacr

uz@

lync

hmyk

ins.

com

.com

.rvt

11/2

0/20

17 2

:22:

36 P

M

S101

B.M

. W

ILLIA

MS

PR

IMA

RY

SC

HO

OL A

DD

ITIO

N

FO

UN

DA

TIO

N P

LA

N

CS

TD

C

JDT

1716

11.2

2.17

CH

ES

AP

EA

KE

VIR

GIN

IA

MS

M

1/8" = 1'-0"S101

FOUNDATION PLAN1

FOUNDATION PLAN NOTES

1. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS TONONBEARING WALLS, WALL CONTROL JOINTS AND OPENINGS.

2. UNLESS OTHERWISE NOTED, ALL ELEVATIONS ARE BASED ON AFINISHED FIRST FLOOR REFERENCE OF 0'-0". ACTUAL FINISHEDFLOOR ELEVATION IS 20.96'. REFER TO ARCHITECTURAL DRAWINGSFOR FINISHED FLOOR MATERIAL.

3. TOP OF ALL FOOTINGS SHALL BE AT ELEVATION -1'-4" UNLESSOTHERWISE NOTED.

4. NOT ALL UTILITY LOCATIONS ARE SHOWN ON PLAN. THECONTRACTOR SHALL COORDINATE THE LOCATIONS, SIZES, ANDINVERTS OF UTILITIES. AT LOCATIONS WHERE UTILITIES PASSBELOW THE TOP OF FOOTING ELEVATION, STEP THE TOP OFFOOTING DOWN ON EACH SIDE PER THE "STEPPED FOOTING DETAIL"AND SLEEVE THE UTILITY THROUGH THE FOUNDATION WALL. THECONTRACOTR MAY, AT HIS OPTION, SLEEVE THE UTILITY THROUGHTHE FOUNDATION PER THE "PIPE SLEEVE DETAIL." ALLPENETRATIONS IN MASONRY WALLS GREATER THAN 1'-4" REQUIRE ABOND BEAM LINTEL.

5. UNLESS OTHERWISE INDICATED, EXTEND WALL FOOTINGS AMINIMUM OF 6 INCHES BEYOND ENDS OF WALLS.

SLAB-ON-GRADE PLAN NOTES

1. SLAB-ON-GRADE JOINTS SHALL BE SAWED JOINTS OR KEYEDCONSTRUCTION JOINTS UNLESS SPECIFICALLY DENOTED TO BE KEYEDCONSTRUCTION JOINTS. CONTRACTOR SHALL COORDINATE ALL SLABJOINTS WITH JOINTS IN BONDED FLOOR FINISHES. REFER TOARCHITECTURAL DRAWINGS FOR FLOOR FINISH JOINT LOCATIONS.

2. FLOOR DRAINS AND FLOOR SINKS ARE NOT SHOWN ON PLAN. REFERTO PLUMBING DRAWINGS FOR LOCATIONS.

3. REFER TO CIVIL DRAWINGS FOR EXTERIOR CONCRETE SLABS ANDPAVING.

WALL FOOTING SCHEDULE

MARK

SIZE REINFORCING

REMARKSWIDTH DEPTH CONTINUOUS TRANSVERSE

WF2 2' - 0" 1'-0" 3-#4 BOT #3 AT 48" OC BOT -

WF3 3' - 0" 1'-0" 4-#4 BOT #3 AT 48" OC BOT -

WF3.5 3' - 6" 1'-0" 5-#4 BOT #3 AT 48" OC BOT -

SLAB-ON-GRADE KEY NOTES

S1 PLACE 1-#4 x 3’-0” IN MIDDLE OF SLAB AT REENTRANT CORNERS WHEREA SLAB JOINT DOES NOT OCCUR.

S2 4" CONCRETE SLAB-ON-GRADE OVER VAPOR RETARDER AND 4" DEPTHOF POROUS FILL UNLESS OTHERWISE INDICATED. REINFORCE SLABWITH 6x6 W2.9xW2.9 WELDED WIRE REINFORCING PLACED 1 1/2" CLEARBELOW TOP OF SLAB. MAINTAIN REINFORCEMENT IN POSITION ONBOLSTERS, CHAIRS OR SPACERS DURING CONCRETE PLACEMENT.

S3 EXISTING 4" CONCRETE SLAB-ON-GRADE.

FOUNDATION PLAN KEY NOTES

N1 REFER TO TYPICAL PIPE SLEEVE DETAILS ON SHEET S501.

N2 DOWEL NEW FOOTING REINFORCING 8" INTO EXISTING FOOTING.

SY

MB

OL

DE

SC

RIP

TIO

ND

AT

E

2.5

K1

2.5

K1

2.5

K1

2.5

K1

SL

SL

SL

SL

SL

SL

SL

JBE = +12'-4"

RTU-19,500#

2

1

6

S301_________

2"

BE

J

2" BEJ

7

S301_________

13

S301_________

12

S301_________

10

S301_________

2.5

K1

2.5

K1

16K

4

16K

4

16K

4

16K

4

16K

4

16K

4

16K

4

16K

4

14K

4

14K

4

14K

4

14K

4

14K

4

14K

4

14K

4

14K

4

14K

4

14K

4

10K

CS

1

10K

CS

1

10K

CS

1

10K

CS

1

10K

CS

1

10K

CS

1

10K

CS

1

10K

CS

1

12K1

12K1

12K1

14K

4

14K

4

14K

4

14K

4

10K

1

2.5

K2

2.5

K2 2.5

K2

2.5

K2

2.5

K2

2.5

K2

2.5

K2

6

S301_________

JBE = +12'-4"

JBE = +12'-4"

SL

JBE = +13'-0"

JBE = +12'-4"

6

S301_________

6

S301_________

8

S301_________

10K

1

GRSR8 50#

GRSR1550#

CU 150#

GRSR8 50#

GRSR12

GRSR8 50#

GRSR8 50#

GRSR1550#

7

S301_________

3

3

3

4

4

4

3

4

TOM EL =+14'-8" (TYP UON)

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

22K

10

JBE = +13'-6"

3

3

3

3

3

16K

4

DJ

R3

15

S301_________

9

S301_________

4

4

EXISTING TOM = +13'-0"±

EXISTING JBE = +12'-1"±

R4

1

22K

10

22K

10

4

3

4

43 3

4

R1

R4

8

S301_________

6

S301_________

JBE = +13'-4"

EX

IST

ING

12"

DE

EP

JO

IST

S

EXISTING JBE = +12'-4"±

EX

IST

ING

20K

4

EX

IST

ING

24K

6

EXISTING JBE = +12'-4"±

SLSL

EXISTING JBE = +13'-4"±

R2

14

S301_________

JBE = +13'-0" 2

EXISTING JBE = +12'-1"±

11

S301_________

SIM TO

R5 R5 R5 R5

JBE = +12'-10"JBE = +12'-9 5/8"

R6

SIM TO

R5

10

S301_________

2

S102_________

6

S301_________

JBE = +13'-3 1/2"

3

S102_________

JBE = +13'-2 1/2"

JBE = +13'-2 1/2"

EXIST STEEL DECK

EXIST JOIST

TOP OF MAS EL -REF ARCH DWGS

8" DEEP CMU BOND BM W/ 2 - #4 CONT BOT (TYP)

CONT L3x3x1/4

JOIST - REF PLAN

8" CMU

VERT WALL REINF REF FND SECTIONS

STEEL DECK

EXIST CMU

EXIST VENEER

2" BEJ 2" BEJ

EXIST STEEL DECK

EXIST JOIST

6" CMU REINF W/ #4 AT 48" OC

8" DEEP CMU BOND BM W/ 1 - #4 CONT BOT

TOP OF MAS EL -REF ARCH DWGS

8" DEEP CMU BOND BM W/ 2 - #4 CONT BOT (TYP)

CONT L3x3x1/4

UPLIFT BRIDGING

JOIST - REF PLAN

8" CMU

VERT WALL REINF REF FND SECTIONS

STEEL DECK

EXIST CMU

Structural Engineers5032 Rouse Dr., Ste 200

Virginia Beach, VA 23462

757.671.8626 - lynchmykins.com

A

B

C

E

F

1 2 3 4 5 6

1 2 3 4 5 6

1/32"=1'-0" 1/16"=1'-0" 3/32"=1'-0" 1/8"=1'-0" 1/4"=1'-0" 3/8"=1'-0" 1/2"=1'-0" 3/4"=1'-0" 1"=1'-0" 1 1/2"=1'-0" 3"=1'-0"0 6"5"4"3"2"1"3" 6" 9"1'0

SHEET NUMBER

1909 CYPRESS AVENUEVIRGINIA BEACH, VA 23451

(757) 417 - 0140

0 3" 6" 9" 1' 1.5"0 6" 1' 2'0 6" 1' 2' 3'0 1' 2' 3' 4'0 2' 4' 6'0 4' 8' 12'0 4' 8' 16'0 4' 8' 16' 24'0 16' 32' 48'

SH

EE

T T

ITLE

PR

OJE

CT

NO

DA

TE

RE

VIS

ION

S

PR

OJ

MG

R

CH

EC

KE

D

DE

SIG

NE

D

DR

AW

N

7 8

6"=1'-0"0 3"2"1"

12"=1'-0"0 1.5"1"1'

7 8

D

LM Project # V17.048

FO

R P

ER

MIT

RE

VIE

W11

-2-1

71

11−22−17

D:\W

ork\

Pro

ject

s\01

- R

evit

Loca

l File

s\V

1704

8_B

MW

Add

ition

_Stru

ct_

R17

_tde

lacr

uz@

lync

hmyk

ins.

com

.com

.rvt

11/2

0/20

17 2

:22:

40 P

M

S102

B.M

. W

ILLIA

MS

PR

IMA

RY

SC

HO

OL A

DD

ITIO

N

RO

OF

FR

AM

ING

PLA

N

CS

TD

C

JDT

1716

11.2

2.17

CH

ES

AP

EA

KE

VIR

GIN

IA

MS

M

1/8" = 1'-0"S102

ROOF FRAMING PLAN1

ROOF FRAMING PLAN NOTES

1. REFER TO FOUNDATION PLAN AND ARCHITECTURAL DRAWINGS FORDIMENSIONS NOT SHOWN.

2. JOIST BEARING ELEVATIONS ARE SHOWN ON PLAN. INTERMEDIATEELEVATIONS SHALL BE STRAIGHT LINES BETWEEN GIVENELEVATIONS. INTERPOLATE AS REQUIRED FOR INTERMEDIATEBEARING ELEVATIONS, UNLESS OTHERWISE NOTED.

3. ROOF FRAMING SHALL BE EQUALLY SPACED NOT TO EXCEED 5'-0" OCTO SUPPORT STEEL ROOF DECK.

4. COORDINATE AND VERIFY ALL MEMBER LOCATIONS, DIMENSIONS,WEIGHTS, OPENING SIZES, AND CURB DIMENSIONS FOR ALLMECHANICAL EQUIPMENT WITH THE ACTUAL EQUIPMENT FURNISHED.INCLUDE THIS INFORMATION ON THE JOIST AND STRUCTURAL STEELSHOP DRAWINGS.

ROOF FRAMING PLAN KEY NOTES

R1 DOUBLE JOIST WITH FOLDING PARTIOTION BELOW. REFER TO"TYPICAL MOVABLE PARTITION SUPPORT DETAIL" ON SHEET S503.

R2 SHORE EXISTING JOIST DURING DEMOLITION. CUT JOIST 2" FROMBOTTOM FACE OF CMU AND BEAR ON NEW CMU WALL.

R3 BUILD NEW CMU WALL 1" CLEAR AROUND EXISTING JOIST.

R4 EXISTING 1 1/2"

R5 REFER TO "TYPICAL DAVIT POST DETAIL" ON SHEET S503 AND TOARCHITECTURAL DRAWINGS FOR LOCATIONS.

R6 CANOPY.

3/4" = 1'-0"S102

SECTION2 3/4" = 1'-0"S102

SECTION3

SY

MB

OL

DE

SC

RIP

TIO

ND

AT

E

1'-4"

VENEER - REF ARCH DWGS

REF CIVIL DWGS

4" CMU

CONT CONC FTG -REF PLAN

#4 AT 48" OC

CONC SLAB - REF PLAN

8" CMU - GROUT ALL CMU SOLID BELOW GRADE

GROUT COLLAR JOINT SOLID BELOW GRADE

8" CMU

REF "TYP EPOXYDOWEL DETAIL"

ROUGHEN CONTACT SURFACE OF EXIST FTG TO FULL 1/4" AMPLITUDE. PAINT W/ BONDING COMPOUND PRIOR TO PLACING NEW CONC

EXIST FTG NEW FTG

#5 AT 12" OC W/ STD 90° HOOK - TILT FROM VERT AS REQ TO MAINTAIN CLR

FOR DETAILS NOT NOTED REF SECTION 1/S301

2" BEJ

REMOVE 3" OF EXIST FTG

EXISTING 8" CMU AT 4AEXISTING 4" CMU AT 4B AND 4C

SLAB - REF PLAN

EXISTING FOOTING

2-#4 CONT

EXISTING SLAB

EXISTING 6" CMU AT 4CEXISTING 4" VENEER AT 4A AND 4B

2'-0"

EXIST WALL BEYOND#4 CONT

#4 AT 12" OC

EXIST CONSTRUCTION

CONC SLAB -REF PLAN

TOP OF MAS -REF ARCH DWGS

JBE - REF PLAN

VENEER - REF ARCH DWGS

CONT L3x3x1/4

STEEL DECK

UPLIFT BRIDGING

JOIST - REF PLAN

8" CMU

VERT WALL REINF

12" WIDE x 8" DEEP CMU BOND BEAM W/ 2-#5 BOT CONT

8" CMU BOND BEAM W/ 2-#4 BOT CONT

STD 90° HOOK

TOP OF MAS -REF PLAN

EXISTING WALL

CONT L3x3x1/4

STEEL DECK

JOIST - REF PLAN

8" CMU

VERT WALL REINF

8" CMU BOND BEAM W/ 2-#4 BOT CONT

8" CMU BOND BEAM W/ 2-#4 BOT CONT

6" CMU

EXISTING JOIST

JOIST -REF PLAN

8" CMU

FOR DETAILS NOT NOTED REF SECTIONS 6/S301 AND 12/S301

JOIST -REF PLAN

JBE - REF PLAN

TOP OF MAS -REF PLAN

CONT L3x3x1/4

8" CMU

JOIST -REF PLAN

TOP OF MAS -REF ARCH DWGS

VERT WALL REINF

VENEER - REF ARCH DWGS

CONT L3x3x1/4

BRIDGING

12" WIDE x 8" DEEP CMU BOND BM W/ 2 - #5 CONT BOT

STD 90° HOOK

8" CMU

FOR DETAILS NOT NOTED REF SECTIONS 6/S301 AND 7/S301

JOIST -REF PLAN

JBE - REF PLAN

TOP OF MAS -REF PLAN

JOIST -REF PLAN

SL

CONT 16" DEEP CMU BOND BEAM REINF W/ 2-#5 CONT

CONT L3x3x1/4

8" CMU

FOR DETAILS NOT NOTED REF SECTION 12/S301

JOIST -REF PLAN

TOP OF MAS -REF PLAN

VERT WALL REINF

EXISTING WALL

EXISTING JOIST

CONT L3x3x1/4

EL VARIES

REMOVE EXISTING 4" BRICK AND INSTALL 4" CMU

EXISTING 4" CMU

L4x4x1/4 LOOSE LINTEL BEAR 8" EACH END

FOR DETAILS NOT NOTED REF SECTION 7/S301

2" BEJ CONT L3x3x1/4

EL = +8'-8"

REF ARCH DWGS

EXISTING 4" SLAB-ON-GRADE TO REMAIN

#4 AT 12" OC

TEMPORARILY UNDERPIN EXISTING SLAB-ON-GRADE UNTIL CONC FOOTING AND WALL HAVE BEEN INSTALLED

CONT CONC FTG -REF PLAN

REMOVE EXISTING SLAB-ON-GRADE 6" FROM FACE OF EXISTING CMU

CONC SLAB -REF PLAN

4-#4 CONT

2-#4 CONT

EXISTING 8" CMU TO REMAIN

8" CMU

8"± 8"±

6"

1'-0"

#4 AT 24" OC

6"

2"

8" CMU

2-#4 CONT

#4 AT 24" OC

BREAK FACE SHELL ON CAVITY SIDE OF EXISTING CMU AND INSTALL #4 IN 2- CELLS BELOW JOIST BEARING ABOVE

EXISTING SLAB

EXISTING FOOTING

1'-0

EXISTING 8" CMU

2" BEJ

10"

2'-0"

BUILD NEW 8" CMU AROUND EXISTING JOIST

EXISTING STEEL DECK

L3x3x1/4 EACH SIDE OF JOIST WEB

EXISTING JOIST

TEMPORARILY SHORE EXISTING JOIST

BRG PLATE - REF TYP DETAIL

SLSL

STEEL DECK

CONT L3x3x1/4

REMOVE EXISTING JOIST BEYOND WALL

FOR DETAILS NOT NOTED REF SECTION 3/S301

8" CMU

L2x2x1/4 AT EACH BRACE

2- 3/4" DIAM x 5" EMBED POST INSTALLED ANCHORS

EXISTING STEEL DECK

EXISTING JOIST

L6x6x3/8x1'-0" AT 32" OC W/ 2- 3/4" DIAM x1 1/2" VERT SLOTTED HOLES AT 8" OC

8" CMU BOND BEAM REINF W/ 2-#4 CONT (TYP)

SL

CONT L5x5x1/4 W/ 3/4" DIAM x 5" EMBED POST INSTALLED ANCHORS AT 48" OC

GROUT SOLID WITHIN 8" OF ANCHOR

EXISTING CMU

2" BEJ

JBE - REF PLAN

EXISTING 4" CMU

TOP OF MAS -REF PLAN

EXISTING STEEL DECK

EXISTING STEEL JOIST

EL VARIES

CONT L3x3x1/4

Structural Engineers5032 Rouse Dr., Ste 200

Virginia Beach, VA 23462

757.671.8626 - lynchmykins.com

A

B

C

E

F

1 2 3 4 5 6

1 2 3 4 5 6

1/32"=1'-0" 1/16"=1'-0" 3/32"=1'-0" 1/8"=1'-0" 1/4"=1'-0" 3/8"=1'-0" 1/2"=1'-0" 3/4"=1'-0" 1"=1'-0" 1 1/2"=1'-0" 3"=1'-0"0 6"5"4"3"2"1"3" 6" 9"1'0

SHEET NUMBER

1909 CYPRESS AVENUEVIRGINIA BEACH, VA 23451

(757) 417 - 0140

0 3" 6" 9" 1' 1.5"0 6" 1' 2'0 6" 1' 2' 3'0 1' 2' 3' 4'0 2' 4' 6'0 4' 8' 12'0 4' 8' 16'0 4' 8' 16' 24'0 16' 32' 48'

SH

EE

T T

ITLE

PR

OJE

CT

NO

DA

TE

RE

VIS

ION

S

PR

OJ

MG

R

CH

EC

KE

D

DE

SIG

NE

D

DR

AW

N

7 8

6"=1'-0"0 3"2"1"

12"=1'-0"0 1.5"1"1'

7 8

D

LM Project # V17.048

FO

R P

ER

MIT

RE

VIE

W11

-2-1

71

11−22−17

D:\W

ork\

Pro

ject

s\01

- R

evit

Loca

l File

s\V

1704

8_B

MW

Add

ition

_Stru

ct_

R17

_tde

lacr

uz@

lync

hmyk

ins.

com

.com

.rvt

11/2

0/20

17 2

:22:

46 P

M

S301

B.M

. W

ILLIA

MS

PR

IMA

RY

SC

HO

OL A

DD

ITIO

N

SE

CT

ION

S

Des

igne

r

Aut

hor

Che

cker

1716

11.2

2.17

CH

ES

AP

EA

KE

VIR

GIN

IA

MS

M

3/4" = 1'-0"S301

SECTION1 3/4" = 1'-0"S301S301S301

SECTION4C4B4A 3/4" = 1'-0"S301

SECTION5

3/4" = 1'-0"S301

SECTION6

3/4" = 1'-0"S301

SECTION12

3/4" = 1'-0"S301

SECTION10 3/4" = 1'-0"S301

SECTION7 3/4" = 1'-0"S301

SECTION8

3/4" = 1'-0"S301

SECTION13

3/4" = 1'-0"S301

SECTION9

3/4" = 1'-0"S301

SECTION2 3/4" = 1'-0"S301

SECTION3

3/4" = 1'-0"S301

SECTION14 3/4" = 1'-0"S301

SECTION15 3/4" = 1'-0"S301

SECTION11

SY

MB

OL

DE

SC

RIP

TIO

ND

AT

E

2'-0"

MA

X

DE

PT

H

D

LAP 44 x BAR

DIA (TYP)

DE

PT

H

D

2'-0" MIN

RE

F P

LA

N2" CLR

MATCH CONTFTG REINF

3" CLR (BOTAND SIDES)

0" (TYP)

TYPICAL STEPPED FOOTING DETAILNTS (DENOTED SF ON PLAN)

STD 90°HOOK (TYP)

LARGER OF

CONT FTG REINF

TRANSVERSE REINF

D OR 1'-4"

EQ EQ TOP OF FTGEL - REF PLAN

CL OF FTG ANDWALL (TYP UON)

FTG - REF PLAN

3" CLR(TYP)

WALL -REFSECTIONS

NTS

TYPICAL WALL FOOTING DETAIL

MAINTAIN 12" MIN AROUNDSLEEVE (TYP) 2

1

LEAN CONC -WIDTH TO MATCHFTG WIDTH ABOVE

8" MIN

BELOW FOOTING

3" CLR (TYP)

SLEEVE (INSIDE DIA2" LARGER THANPIPE OUTSIDE DIA)

ADDED BAR OFSAME SIZE ANDSPACING AS TYPFTG REINF

MAINTAIN 12" MINAROUND SLEEVE(TYP)

#4 TIE BARS

PIPE - REF PMEDWGS

2" CLR

FTG - REFPLAN

STD 90°HOOK

PIPE - REFPME DWGS

FTG - REFPLAN

THROUGH FOOTING

#4 TIE BARS

SLEEVE (INSIDE DIA2" LARGER THANPIPE OUTSIDE DIA)

NTS

TYPICAL PIPE SLEEVE DETAILS

NOTE: SLEEVES SHALL NOT BE LOCATED IN OR UNDER COL FTGS.

1 1/2"

DE

PT

H

(D)

D/3

D/3

D/3

NEW POURPREVIOUS POUR

TIE BAR EA SIDE

3" CLR

REINF IS CONT THRU JOINT

2" CLR

KEY FULL WIDTHOF FTG

2-#5 x 4'-0" CONT THRUJOINT WHERE NO CONTTOP BARS ARE REQD

3" CLR (BOTAND SIDES)

NTS

TYPICAL FOOTING CONSTRUCTIONJOINT DETAIL

NTS

TYPICAL CORNER AND INTERSECTIONDETAILS

3" CLR (TYP)

TRANSVERSE REINF (TYP)

CONT REINF (TYP)

NTS

TYPICAL DETAIL AT INTERSECTION OFNEW AND EXISTING FOOTINGS

2" BEJ

ROUGHEN CONTACTSURFACE OF EXIST FTGTO FULL 1/4" AMPLITUDE.PAINT W/ BONDINGCOMPOUND PRIOR TOPLACING NEW CONC EXIST FTG NEW FTG

CL OF DOWELS

REF "TYP EPOXYDOWEL DETAIL"

8"

EMBED

16"

12" LAP

EQ

EQ

STEP NEW FTG ASREQD TO MATCH EXISTFTG

NEW CMU WALL

NTS

TYPICAL EPOXY DOWEL DETAIL

DRILL HOLES INTO EXIST FTG TORECEIVE DOWELS. CLEAN HOLESTHOROUGHLY OF DEBRIS AND FILL W/ EPOXY. DIA OF HOLES SHALL BE AS RECOMMENDED BY MFR OF EPOXY MATL. IF NOT SPECIFIED BY EPOXY MFR, DIA OF HOLES SHALL BE 1/8" LARGER THAN DOWEL SIZE.

EXIST FTG

8"

EM

BE

D(U

ON

)

LA

P L

EN

GT

H

NOTE: VERT DOWEL SHOWN. HORIZ DOWEL SIMILAR.

NTS

TYPICAL DEPRESSED SLAB DETAIL(DENOTED THUS: ON PLAN)

CONC SLAB -REF PLAN

REF ARCH DWGS

REF PLAN

2t

t

t

NTS

TYPICAL EXTERIOR DOORS / OPENINGS DETAIL

#4 AT 12" OC TOP W/ STD 90° HOOK

1-#4 MOS, EA SIDE

1/2" EXPANSION JOINT MATERIAL (TYP)

MAS WALL

1-#4

SLAB-ON-GRADE

WALL BEYOND

REF CIVIL DWGS

1/2" EXPANSION JOINT MATERIAL

1-#4

#4 AT 12" OC TOP W/ STD 90° HOOK

2'-0"

8"

2'-0"

OPENING

(TYP)

1'-0"

1'-4

"

2" CLR

1

1

PLAN SECTION

1"

CLR

COORD W/ ARCH SILL DETAILS

NTS

TYPICAL DETAIL AT INTERIOR DOOR OPENINGS

CMU WALL

FACE OF WALLBEYOND

CONC SLAB -REF PLAN

1/2" EXP JT FILLER -CONT AROUND CMU(TYP AT JAMBS)

CONC SLAB -REF PLAN

FTG - REFPLAN

SECTION PLAN

REF "TYP KCJ DETAIL"

KC

J

NTS

TYPICAL KEYED CONSTRUCTION JOINTDETAIL

6" 6"

EDGE TO 1/8" RADIUS BEFORE REMOVING BULKHEAD

JOINT SEALANT

CL OF JOINT

NEW POURPREVIOUS POUR

CONC SLAB -REF PLAN

PAINT FACE OF PREVIOUS POUR W/ CURING COMPOUND BEFORE MAKING NEW POUR

CONT 2x4 KEY

8"

1"

(DENOTED KCJ ON PLAN)

1

1

NTS

TYPICAL SAWED JOINT DETAIL

JOINT SEALANT

CL OF JOINT

CONC SLAB -REF PLAN

CUT EVERY OTHER WIRE AT JOINT

(DENOTED SJ ON PLAN)

t/4 DEEP

t = SLAB THICKNESS

1/8" JOINT

NTS

TYPICAL SLAB REMOVAL ANDREPLACEMENT DETAIL

SAWCUT 1" DEEP ATPERIMETER OF AREA TO BE REMOVED AND BREAK OUT EXIST SLAB

NEW SLABEXISTING SLAB

CLEAN AND REUSE PORTION OF EXIST WWR(LAP 12" MIN W/ NEW)

SURFACE OF EXIST SLAB SHALL BESQUARE AND SOUND

CONC SLAB -REF PLAN (MATCH EXIST)

CLEAN SURFACE ANDPAINT WITH BONDINGCOMPOUND PRIOR TOPLACING NEW CONC

NTS

TYPICAL THICKENED SLAB / KEYEDCONSTRUCTION JOINT DETAIL

3-#4 CONT

CONC SLAB -REF PLAN

3" CLR (TYP)

(DENOTED TS/KCJ ON PLAN)

4" 6" 6" 4"

WALL THICKNESS

KCJ

REF "TYPICAL EPOXY DOWEL DETAIL" NON-BRG MAS

WALL

VERT WALL REINF

NTS

TYPICAL THICKENED SLAB DETAIL(DENOTED TS ON PLAN)

2-#4 CONT

CONC SLAB -REF PLAN

3" CLR (TYP)

4" 4" 4" 4"

WALL THICKNESS

REF "TYPICAL EPOXY DOWEL DETAIL" NON-BRG MAS

WALL

VERT WALL REINF

Structural Engineers5032 Rouse Dr., Ste 200

Virginia Beach, VA 23462

757.671.8626 - lynchmykins.com

A

B

C

E

F

1 2 3 4 5 6

1 2 3 4 5 6

1/32"=1'-0" 1/16"=1'-0" 3/32"=1'-0" 1/8"=1'-0" 1/4"=1'-0" 3/8"=1'-0" 1/2"=1'-0" 3/4"=1'-0" 1"=1'-0" 1 1/2"=1'-0" 3"=1'-0"0 6"5"4"3"2"1"3" 6" 9"1'0

SHEET NUMBER

1909 CYPRESS AVENUEVIRGINIA BEACH, VA 23451

(757) 417 - 0140

0 3" 6" 9" 1' 1.5"0 6" 1' 2'0 6" 1' 2' 3'0 1' 2' 3' 4'0 2' 4' 6'0 4' 8' 12'0 4' 8' 16'0 4' 8' 16' 24'0 16' 32' 48'

SH

EE

T T

ITLE

PR

OJE

CT

NO

DA

TE

RE

VIS

ION

S

PR

OJ

MG

R

CH

EC

KE

D

DE

SIG

NE

D

DR

AW

N

7 8

6"=1'-0"0 3"2"1"

12"=1'-0"0 1.5"1"1'

7 8

D

LM Project # V17.048

FO

R P

ER

MIT

RE

VIE

W11

-2-1

71

11−22−17

D:\W

ork\

Pro

ject

s\01

- R

evit

Loca

l File

s\V

1704

8_B

MW

Add

ition

_Stru

ct_

R17

_tde

lacr

uz@

lync

hmyk

ins.

com

.com

.rvt

11/2

0/20

17 2

:22:

47 P

M

S501

B.M

. W

ILLIA

MS

PR

IMA

RY

SC

HO

OL A

DD

ITIO

N

TY

PIC

AL D

ET

AIL

S

CS

TD

C

JDT

1716

11.2

2.17

CH

ES

AP

EA

KE

VIR

GIN

IA

MS

MS

YM

BO

LD

ES

CR

IPT

ION

DA

TE

NTS

BOND BEAM LINTEL DETAILS

D

8"

BRG

8"

BRG

2-#4 BOT

2-#6 TOP & BOT

BOND BEAM LINTEL SCHEDULE

DEPTH'D'

CLEAR SPAN REINFORCING

3/8"

1/2" CLR (TYP 3-SIDES)

50 DUROMETER NEOPRENE PAD

CONTROL JOINT- REF ARCH DWGS

EL - REF ARCH OR MECH DWGS REF BOND

BM LINTEL SCHED

JAMB VERT REINF - REF TYP CONC MAS DETAILS

BRG PAD

VERT WALL REINF - OFFSET AND LAP VERT REINF 48 x BAR DIA AT CONTROL JOINT

SEALANT

BOT REINF

NOTES:

1. REFER TO ARCHITECTURAL DRAWINGS FOR SIZE AND LOCATION OF OPENINGS; FOR DUCT OPENINGS REFER TO MECHANICAL DRAWINGS.

2. REFER TO ARCHITECTURAL DRAWINGS FOR WIDTH OF LINTEL.

3. SCHEDULE APPLIES ONLY TO LINTELS NOT OTHERWISE SHOWN ON THE DRAWINGS.

0 TO 6'-4"

6'-5" TO 7'-4" 16"

8"

TYPICAL SECTION TYPICAL JAMB JAMB AT CONTROL JOINT

MAS OPNG

VENEER MAS NOT SHOWN - REF MAS SHELF ANGLE DETAILS

INTERLOCKING BLOCK OROTHER DEVICE FOROUT-OF-PLAN SHEARTRANSFER AT CJ ABOVELINTEL

WIDTH'W'

'W'

8"

8"

TOP REINF2-#5 TOP & BOT7'-5" TO 10'-0" 24" 8"

'D'

8"

CONT REINF

0" (TYP)

GROUT SOLID

CORNER INTERSECTIONCLOSED BOTTOM

NTS

TYPICAL BOND BEAM REINFORCINGDETAILS

OPEN BOTTOM

3"

1 1

/2"

2 1

/2"

WALL THICKNESS (TYP)

LAP

1'-0"

LAP

1'-0"

LAP

1'-0"

LA

P

1'-6"

NTS

BRICK SHELF ANGLE DETAILS

3/4" MAX

8"(*)

BRG

L4x4x3/8VENEER

BRICK SHELF ANGLE - REF SCHED (LLV WHERE LEGS ARE UNEQUAL)

WALL TYPE BACKUP - REF ARCH DWGS

NOTES:

1. REFER TO ARCHITECTURAL DRAWINGS FOR SIZE AND LOCATION OF ALL OPENINGS.

2. SHELF ANGLE SCHEDULE APPLIES ONLY TO SHELF ANGLES NOT OTHERWISE DETAILED.

SIZE

7'-5" TO 10'-0"

0 TO 7'-4"

CLEAR SPAN

BRICK SHELF ANGLE SCHEDULE

REF BRICK SHELF ANGLE SCHED

MAS OPNG

TYPICAL SECTION TYPICAL JAMB

* WHERE JAMBS BTWN ADJACENT OPNGS IS 16" OR LESS, PROVIDE CONT ANGLES.

L6x4x7/16 (LLV)

NTS

TYPICAL DETAIL AT INTERSECTION OFEXTERIOR AND INTERIOR CMU WALLS

3" 24"3"

( )3/16"x1 1/4"

VERTICAL REINFORCING -REF PLAN

EXTERIOR WALL

RAKE OUT AND CAULK TO FORM CONTROL JOINTINTERIOR WALL

EMBED BENT ENDS IN CORES FILLED WITH MORTAR OR CONCRETE

STRAP ANCHORS AT VERTICAL SPACING OF 32" OC

NTS

STEPPED BOND BEAM DETAIL

40" LAP

BOND BM

MAS WALL BOND BM REINF

NTS

TYPICAL FIRE DOOR DETAILS

CLEAR SPAN -

REF ARCH DWGS

RE

F

EL - REF ARCH DWGS

FIRE CAULK

VERT WALL REINF

3/8" CJ

STD 90° HOOK

VERT WALL REINF EA CELL

VERT REINF

2 - LAYERS 30# FELT

HEAD ELEVATION

CONC SLAB REINF W/ #5 AT 12" OC EW BOT W/ 180° HOOKS

2'-0" BOND BEAM W/ 2 - #5 TOP AND BOT (TYP)

BEJ - REF PLAN

WA

LL

BO

ND

BE

AM

WALL BOND BEAM CLEAR SPAN

7 5

/8"

REF ARCH DWGS

REF PLAN

AR

CH

DW

GS

EL = +10'-0"

3/8" CJ

NTS

TYPICAL CONCRETE MASONRY REINFORCING DETAILS

EQ EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

CORNER

TYPICAL

INTERSECTION

WALL THICKNESS

AT VERT CONTROL JOINT

1 - VERT BAR EA SIDE OF CONTROL JOINT

VERT BAR SAME AS TYP WALL REINF (TYP)

OPENING < 3'-0" 3'-1" < OPENING > 10'-0"

OPENING NTE 7'-4" EACH SIDE

OPENING ABOVE3 - VERT BARS

( 1 BAR EA CELL)

2 - VERT BARS

OPNG ABOVE

1 - VERT BAR

1 - VERT BAR

WALL THICKNESS

CONTROL JT -REF ARCH DWG

OPNG ABOVE

2'-0"

GROUT EXISTING JAMBS SOLID (GC TO VERIFY IF EXISTING JAMBS ARE GROUTED SOLID)

HORIZONTAL BOND BEAM REINFORCED WITH 2-#5. LOCATE 2'-0" FROM TOP AND AT BOTTOM OF OPENING

DRILL 6" INTO EXISTING CMU AND EPOXY #4x1'-0" LONG DOWEL. PROVIDE DOWELS AT 2'-0" MAX AT EXISTING JAMBS

TOP OF EXISTING CONCRETE SLAB

EXISTING CONCRETE FOOTING

GROUT SOLID 2 SIDES AND BOTTOM OF NEW CMU FILL

TYPICAL ELEVATION

NTS

TYPICAL MASONRY WALLINFILL AT EXISTING OPENING

NTS

TYPICAL LINTEL BEARINGON EXISTING MASONRY DETAIL

MAS OPNG8" BRG

EA END

D

INSTALL #5 JAMB REINF IN EXISTING CMU EACH SIDE OF OPENING MAKE OPENING IN A

SAWTOOTH FASHION TO INSTALL NEW 8" CMU AT JAMBS

REF 'BOND BEAM LINTEL SCHEDULE'

EXIST CMU

BRACE EXISTING CMU WALL TO EXISTING STRUCTURE ABOVE AT EACH JAMB PER TYPICAL DETAILS

BE

J

BEJ

#4 EA CELL (TYP)

8" CMU (TYP)

FIRE CAULK

FIRE CAULK

BEJ

BE

J

8" CMU (TYP)

FIRE CAULK

#4 EA CELL(TYP)

FIRE CAULK

BE

J

BEJ

BE

J

#4 EA CELL (TYP)

8" CMU (TYP)

FIRE CAULK

FIRE CAULK

EXIST CMU

#4 EA CELL (TYP)

8" CMU (TYP) FIRE CAULK

FIRE CAULK

BE

J

Structural Engineers5032 Rouse Dr., Ste 200

Virginia Beach, VA 23462

757.671.8626 - lynchmykins.com

A

B

C

E

F

1 2 3 4 5 6

1 2 3 4 5 6

1/32"=1'-0" 1/16"=1'-0" 3/32"=1'-0" 1/8"=1'-0" 1/4"=1'-0" 3/8"=1'-0" 1/2"=1'-0" 3/4"=1'-0" 1"=1'-0" 1 1/2"=1'-0" 3"=1'-0"0 6"5"4"3"2"1"3" 6" 9"1'0

SHEET NUMBER

1909 CYPRESS AVENUEVIRGINIA BEACH, VA 23451

(757) 417 - 0140

0 3" 6" 9" 1' 1.5"0 6" 1' 2'0 6" 1' 2' 3'0 1' 2' 3' 4'0 2' 4' 6'0 4' 8' 12'0 4' 8' 16'0 4' 8' 16' 24'0 16' 32' 48'

SH

EE

T T

ITLE

PR

OJE

CT

NO

DA

TE

RE

VIS

ION

S

PR

OJ

MG

R

CH

EC

KE

D

DE

SIG

NE

D

DR

AW

N

7 8

6"=1'-0"0 3"2"1"

12"=1'-0"0 1.5"1"1'

7 8

D

LM Project # V17.048

FO

R P

ER

MIT

RE

VIE

W11

-2-1

71

11−22−17

D:\W

ork\

Pro

ject

s\01

- R

evit

Loca

l File

s\V

1704

8_B

MW

Add

ition

_Stru

ct_

R17

_tde

lacr

uz@

lync

hmyk

ins.

com

.com

.rvt

11/2

0/20

17 2

:22:

51 P

M

S502

B.M

. W

ILLIA

MS

PR

IMA

RY

SC

HO

OL A

DD

ITIO

N

TY

PIC

AL D

ET

AIL

S

CS

TD

C

JDT

1716

11.2

2.17

CH

ES

AP

EA

KE

VIR

GIN

IA

MS

M

3/4" = 1'-0"S502

PLAN DETAILC 3/4" = 1'-0"S502

PLAN DETAILA 3/4" = 1'-0"S502

PLAN DETAILB 3/4" = 1'-0"S502

PLAN DETAILD

SY

MB

OL

DE

SC

RIP

TIO

ND

AT

E

NTS

TYPICAL MASONRY ANCHORAGE DETAILS

CONT ANGLE

PL1/4x6x3 W/ 1-3/4"Ø HEADED STUD AT 48" OC

8" DEEP CMU BOND BM W/ 2-#4 CONT

BREAK FACE SHELL AS REQD TO INSTALL STUD

CMU

5" (TYP UON) 4" AT 6" CMU

EQ

EQ

1/8

CONT L3x3x1/4

NTS

TYPICAL NON-BEARING MASONRY PARTITION BRACING DETAILSNOTE: PROVIDE SUPPORT FRAME AT EACH JOIST OR 6'-0" OC MAX

L2x2x1/4 - LENGTH = 0'-0" TO 6'-0"L3x3x1/4 - LENGTH = 6'-1" TO 9'-6"

PARALLEL WITH JOISTS

L3x3x1/4 x 0'-6" FLUSH TO WALL EA SIDE

8" DEEP CMU BOND BM AT UPPERMOST FULL COURSE OFPARTITION REINF W/ 2- #4 CONT

L2x2x1/4 - LOCATE AT TOP CHORD PANEL POINTS

PERPENDICULAR TO SLOPED JOISTS

L2x2x1/4 x 0'-6" CLIPS -LOCATE AT BOT CHORD PANEL POINTS

L2x2x1/4 - LENGTH = 0'-0" TO 6'-0"L3x3x1/4 - LENGTH = 6'-1" TO 9'-6"

WALLS ABOVE CEILING WALLS TO UNDERSIDE OF DECK

PERPENDICULAR TO JOISTS PARALLEL WITH JOISTS

ROOF OR SLAB (TYP)

STEEL DECK

L3x3x1/4 x 0'-6", EA SIDE AT EA JOIST

L3x3x1/4, EA SIDE AT EA BRIDGING LINE

1" CLR BTWN TOP OF MAS AND UNDERSIDE OF DECK- FOR COMPRESSIBLE FILLER (IF ANY) REF ARCH DWGS (TYP)

BUILD MAS 1" (MIN) CLR AROUND ALL JOISTS AND BRIDGING

1/8TYP

8" DEEP CMU BOND BM AT UPPERMOST FULL COURSE OFPARTITION. REINF W/ 2- #4 CONT

1/8TYP

NOTES :

POINTLOADS

CL OF PANELPOINT

A. POSITION HANGER RODS ON JOIST CENTERLINES BETWEEN CHORD JOIST MEMBERS. DO NOT USE C-CLAMPS TO CHORD ANGLE LEGS.

B. WHERE CONCENTRATED LOADS EXCEEDING 300 LBS ARE APPLIED TO TOP CHORDS OR HUNG FROM BOTTOM CHORDS BETWEEN PANEL POINTS, ADD 2-L1x1x1/8 TO PANEL POINT AS SHOWN FOR K SERIES JOISTS.

POINT LOAD

JOIST

NOTE 'B'

JOISTCHORD

JOISTCHORD

DETAIL

DETAIL

ADDEDANGLES

DETAIL

DETAIL

JOISTCHORD

JOISTCHORD

HANGER ROD -NOTE 'A'

ELEVATION

CL OF ADDEDANGLES

C

B A

A

C

B

D

NTS

TYPICAL DETAIL AT CONCENTRATED LOADS ON JOISTS

1/8

TYPEAEND,EAANGLE

CL OF HANGER ROD

HANGER ROD -NOTE 'A'

CL OF HANGER ROD

D

NTS

TYPICAL JOIST BEARING ON MASONRY WALL DETAILS

BEAR JOISTFULL LENGTHOF BRG PL

VERT WALL REINF

JOIST

ONE SIDE

3 1/2" JOIST SEAT

VERT WALL REINF

JOIST BEYOND

TWO SIDES

3 1/2" JOIST SEAT

CMU CUT COURSE AS REQD

BRG PL1/4x8x6 W/ 2-1/2"Ø x 4" HEADED STUDS

CMU

8" DEEP CMUBOND BM W/ 2- #4BOT CONT

8" DEEP CMUBOND BM W/ 2-#4 BOT CONT

BRG PL1/4x8x6 W/ 2-1/2"Ø x 4" HEADEDSTUDS SET ANDLEVELED IN FULLMORTAR BED 1/2"

1/8 1

1/8 1

1/8 1

1/8 1

1/2"

MIN4" BRG

NOTE: OFFSET JOISTS TO PROVIDE MINIMUM BEARING WHENEVER POSSIBLE. OTHERWISE, BUTT JOISTS ENDS TOGETHER OVER SUPPORT CENTERLINE AND PROVIDE BEARING PL1/2x12x7 WITH 3- 3/4"Øx6" HEADED STUDS AND SPECIAL JOIST ENDS PER SJI REQUIREMENTS.

CUT COURSE AS REQD

NOTE: STAGGER JOIST BEARING ON WALL TO AVOID CONFLICT WITH PLATES

AT DOUBLE JOISTS

BRG PL1/2x12x7 W/ 3-1/2"Ø x 6" HEADED STUDS

1/8 1

1/8 1TYP

DBL JOISTS

6"

NTS

TYPICAL MOVABLE PARTITION SUPPORT DETAIL

L4x4x1/4 AT 4'-0" MAX

JOIST BRIDGING

JOIST

TYPICAL

1

TRACK AND MOVABLE PARTITION BY OPERABLE PARTITION MFR

(2)-L2 1/2x2 1/2x1/4 AT EA L4x4

CONT WT7x26.5 -SPACE BOLTS PER PARTITION MFR'S REQUIREMENTS

L2 1/2x2 1/2x1/4 AT EA L4x4 (ALTERNATE EACH SIDE)

PL3/8 W/ 2- 3/4" DIAM BOLTS

JOIST

PL 1/4

8" CMU -REF SECTIONS

AT CMU

REF 'TYPICAL'

PL 1/4x8x8 W/ 2-1/2" DIAMx5" EMBED HEADED ANCHORS

4" BRG

6"

BOS EL = +9'-4"

NTS

TYPICAL ROOF TOP MECHANICAL UNIT SUPPORT DETAILS

L4x4x1/4 SUPPORTFRAME

L4x4x1/4 SUPPORT FRAME

L4x4x1/4 SUPPORTFRAME (TYP)

REF "TYP DETAILATCONCENTRATEDLOADS ON JOIST"

JOIST JOIST

STEEL DECK

MECH UNIT ANDCURB - REF MECHDWGS

STEEL DECK

JOISTS

MECH UNIT ANDCURB - REFMECH DWGS

PART PLAN SECTION

STEEL DECK

PC OFL6x4x5/16x0'-6" ATEA END OF L4x4BTWN JOISTS

SECTION

AB

A B

2x4 BLOCKING BETWEEN EA STEEL DECK RIB

REMOVE AS REQD AT DUCT OPENINGS

NTS

TYPICAL STEEL ROOF DECK OPENING DETAIL

6" MIN EA SIDE OF OPNG

EXTEND PLATE BEYOND OPENING AS REQUIRED TO LAP WITH FIRST FULL LOW RIB

71 MIL PLATE WELDED OR FASTENED AT 6" OC W/ #10 SCREWS TO EA DECK RIB ALL AROUND PERIMETER OF PLATE AND OPENING

12" MAX

NOTES:

1. FOR OPENINGS LESS THAN 6", NO REINFORCEMENT IS REQUIRED.

2. FOR OPENINGS GREATER THAN 12", PROVIDE ANGLE FRAMING PER "STEEL DECK NOTES" ON SHT S001.

DECK RIB (TYP)

STEEL ROOF DECK

12" MAX

NTS

TYPICAL JOIST BRIDGING DETAILS

AT WALL AT STEEL BEAM

ALLBRIDGINGCONTACTPOINTSREPEAT DETAIL ON OPPOSITE SIDE

OF WALL WHERE APPLICABLE

GROUT CELLS SOLID 12" MIN ALL AROUND AT ANCHOR BOLT (TYP)

COPE VERT ANGLE AS REQUIRED

WELD PL W/ HEADED STUDS

PARAPET OR WALL ABOVE -REF ARCH DWGS CONT ANGLE AND EMBED

PL - REF "TYPICAL MASONRY ANCHORAGE DETAIL"

ROOF DECK (TYP)

JOIST BRIDGING PER SJI SPECIFICATION UON

PROVIDE CROSS BRIDGING IN NEXT TO LAST BAY AT EACH BRIDGING LINE

L3x3x1/4 (LENGTH = DEPTH OF ADJACENT JOIST) AT EACH BRIDGING LINE - COPE AND WELD TO CONT ANGLE AT TOP

REPEAT ON OPPOSITE SIDE OF BEAM WHERE APPLICABLE

BEAM

PROVIDE CROSS BRIDGING IN LAST BAY AT EACH BRIDGING LINE

NOTE: VERTICAL WALL REINFORCING, BOND BEAMS AND VENEER MASONRY NOT SHOWN. COORDINATE WITH PLANS, OTHER DETAILS AND ARCHITECTURAL DRAWINGS.

AT CHANGES IN JOIST DEPTH

NTS

TYPICAL DAVIT POST DETAIL

3/16

ROOF DECK -REF PLAN

JOIST - REF PLAN (TYP)

GALVANIZED HSS6x6x1/4 GUY WIRE POST - LOCATE NEAREST TO CENTER BETWEEN JOISTS (REF PLAN)

FALL PROTECTION LINE (BY OWNER)

D-RING RATED FOR 3,000 LBS IN ANY DIRECTION

L4x4x1/4 EACH SIDE OF POST (L5x5x3/8 AT SPANS GREATER THAN 7'-0")

1"

PERDECK

SUPPORTPATTERN

CAP PL1/4

1/4TYP

TYP

1'-0"

1'-8"

MA

X

LOCATE AT PANEL POINTS OR ADD CONCENTRATED LOAD ANGLES

Structural Engineers5032 Rouse Dr., Ste 200

Virginia Beach, VA 23462

757.671.8626 - lynchmykins.com

A

B

C

E

F

1 2 3 4 5 6

1 2 3 4 5 6

1/32"=1'-0" 1/16"=1'-0" 3/32"=1'-0" 1/8"=1'-0" 1/4"=1'-0" 3/8"=1'-0" 1/2"=1'-0" 3/4"=1'-0" 1"=1'-0" 1 1/2"=1'-0" 3"=1'-0"0 6"5"4"3"2"1"3" 6" 9"1'0

SHEET NUMBER

1909 CYPRESS AVENUEVIRGINIA BEACH, VA 23451

(757) 417 - 0140

0 3" 6" 9" 1' 1.5"0 6" 1' 2'0 6" 1' 2' 3'0 1' 2' 3' 4'0 2' 4' 6'0 4' 8' 12'0 4' 8' 16'0 4' 8' 16' 24'0 16' 32' 48'

SH

EE

T T

ITLE

PR

OJE

CT

NO

DA

TE

RE

VIS

ION

S

PR

OJ

MG

R

CH

EC

KE

D

DE

SIG

NE

D

DR

AW

N

7 8

6"=1'-0"0 3"2"1"

12"=1'-0"0 1.5"1"1'

7 8

D

LM Project # V17.048

FO

R P

ER

MIT

RE

VIE

W11

-2-1

71

11−22−17

D:\W

ork\

Pro

ject

s\01

- R

evit

Loca

l File

s\V

1704

8_B

MW

Add

ition

_Stru

ct_

R17

_tde

lacr

uz@

lync

hmyk

ins.

com

.com

.rvt

11/2

0/20

17 2

:22:

53 P

M

S503

B.M

. W

ILLIA

MS

PR

IMA

RY

SC

HO

OL A

DD

ITIO

N

TY

PIC

AL D

ET

AIL

S

CS

TD

C

JDT

1716

11.2

2.17

CH

ES

AP

EA

KE

VIR

GIN

IA

MS

MS

YM

BO

LD

ES

CR

IPT

ION

DA

TE