Columbus JACK /Regent “The Strength of Experience”. Axle Jack Model 2295-10PR. Capacity 95 tons Hydraulic Stroke 11 inches Screw Extension 5 inches Closed Height 10 inches Extended Height 26 inches Operating Pressure First Stage4335 psi - PowerPoint PPT Presentation
Citation preview
© Columbus JACK Corp. 2011
Axle Jack
Model 2295-10PR
ColumbusJACK/Regent“The Strength of Experience”
© Columbus JACK Corp. 2011
2295-10PR
• Capacity 95 tons
• Hydraulic Stroke 11 inches
• Screw Extension 5 inches
• Closed Height 10 inches
• Extended Height 26 inches
• Operating Pressure
– First Stage 4335 psi
– Second Stage 6795 psi
© Columbus JACK Corp. 2011
2295-10PR
Cylinder Support Caster
Air Pump
Accumulator
Cylinder Assembly
© Columbus JACK Corp. 2011
2295-10PR
Hand Pump
Towbar
Control Console
© Columbus JACK Corp. 2011
2295-10PR
© Columbus JACK Corp. 2011
2295-10PR
Air Control Valve
Release Valve
Dual Reading Load Gauge (Optional)
© Columbus JACK Corp. 2011
2295-10PR
Air Pressure Relief Valve
Air Inlet
System Relief Valve
Shown Without Optional Load Gauge
Release Valve
© Columbus JACK Corp. 2011
2295-10PR
Accumulator Charge Port
Test Port
Accumulator Relief Valve
© Columbus JACK Corp. 2011
2295-10PR
Cylinder Bushing
O-Ring
O-Ring
1st Stage Ram
2nd Stage Ram
O-Ring
© Columbus JACK Corp. 2011
Operation – To Raise
• Locate jack under aircraft lifting point.
• Raise towbar to lower cylinder to ground.
• Raise rain hat and unscrew screw extension as required.
• Close release valve.
• Operate pump until rams have raised aircraft to desired height.
© Columbus JACK Corp. 2011
Operation – To Lower
• Slowly open release valve.
– Opening release valve too quickly will cause restrictor fuse to actuate, resulting in the rams lowering very slowly.
– To reset the restrictor fuse, close release valve, operate hand pump 1-2 strokes. Open release valve slowly to lower rams.
• When load is removed from cylinder rams, accumulator will “power retract” rams to their fully collapsed position.
© Columbus JACK Corp. 2011
Operation – To Lower
• Lower screw extension completely.
• Place rain hat over cylinder.
© Columbus JACK Corp. 2011
• To verify/recharge the nitrogen pressure in the accumulator:
– Open release valve on console and insure rams are fully collapsed.
Special Maintenance Instructions
– Open accumulator isolation valve under frame.
– Attach 0-300 psi test gauge to top of accumulator.
– Verify accumulator charge is 225 + 5 psi. Re-charge as necessary with nitrogen.
– Close accumulator isolation valve.
© Columbus JACK Corp. 2011
• To recharge hydraulic fluid pressure in the accumulator:
– Open release valve on console.
– Attach 0-600 psi test gauge to test port at bottom of accumulator.
– Close release valve on console.
– Fully extend both cylinder rams.
– Open accumulator isolation valve under frame.
– Loosen hose fitting at top of cylinder assembly.
Special Maintenance Instructions
© Columbus JACK Corp. 2011
Special Maintenance Instructions
– Using hand pump, slowly pump hydraulic fluid until all entrapped air is removed.
– Tighten hose fitting at top of cylinder assembly.
– Loosen gauge fitting at test port at bottom of accumulator.
– Using hand pump, slowly pump hydraulic fluid until all entrapped air is removed.
– Tighten gauge fitting at test port.
– Using hand pump, pressurize system to 425 psi maximum.
– Close accumulator isolation valve under frame.
© Columbus JACK Corp. 2011
Special Maintenance Instructions
– As there may be some residual pressure in the system, slowly remove gauge from test port on bottom of accumulator and install cap.
– Cycle rams several times to verify smooth extension and retraction.
– Open release valve on console and verify rams retract fully.
© Columbus JACK Corp. 2011