The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 1 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
SAMPLE INFORMATION: Description: 356 ~ white, black, cobalt, 517~ white, black, cobalt, 728 ~ white, black, cobalt, 729
~ white, black, cobalt, 730 ~ white, black, cobalt, 767 ~ white, black, cobalt Assortment: - Purchase Order Number: -
SKU/style No.: - Toy Co./Agency: -
Factory/Supplier/Vendor: - Country of Origin: China
Country of Distribution: - Labeled Age Grade: -
Quantity Submitted: Refer to Page 2 Recommended Age Grade: -
Testing Period: 02/19/2016 – 02/26/2016 Tested Age Grade: -
OVERALL RESULT: PASS
At the request of the client, the following tests were conducted: CONCLUSION TEST(S) CONDUCTED
PASS California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior
PASS FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior
ANSECO GROUP (HK) LIMITED
Vincent Chow Wai Kit Manager, Chemical Laboratory
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 2 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
QUANTITY SUBMITTED DETATILED: Style description Qty.
356 ~ white mug 8 pcs
356 ~ black mug 7 pcs
356 ~ cobalt mug 8 pcs
517 ~ white mug 6 pcs
517 ~ black mug 7 pcs
517 ~ cobalt mug 8 pcs
728 ~ white mug 6 pcs
728 ~ black mug 11 pcs
728 ~ cobalt mug 7 pcs
729 ~ white mug 6 pcs
729 ~ black mug 7 pcs
729 ~ cobalt mug 6 pcs
730 ~ white mug 7 pcs
730 ~ black mug 10 pcs
730 ~ cobalt mug 10 pcs
767 ~ white mug 7 pcs
767 ~ black mug 6 pcs
767 ~ cobalt mug 6 pcs
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 3 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 1A 1B 1C 1D 1E 1F
Volume of acid used (mL) 330 330 330 330 330 330
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 4 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 2A 2B 2C 2D 2E 2F
Volume of acid used (mL) 330 330 330 330 330 330
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 5 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 3A 3B 3C 3D 3E 3F
Volume of acid used (mL) 330 330 330 330 330 330
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 6 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 4A 4B 4C 4D 4E 4F
Volume of acid used (mL) 420 420 420 420 420 420
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 7 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 5A 5B 5C 5D 5E 5F
Volume of acid used (mL) 420 420 420 420 420 420
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 8 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 6A 6B 6C 6D 6E 6F
Volume of acid used (mL) 420 420 420 420 420 420
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 9 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 7A 7B 7C 7D 7E 7F
Volume of acid used (mL) 450 450 450 450 450 450
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 10 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 8A 8B 8C 8D 8E 8F
Volume of acid used (mL) 450 450 450 450 450 450
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 11 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 9A 9B 9C 9D 9E 9F
Volume of acid used (mL) 450 450 450 450 450 450
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 12 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 10A 10B 10C 10D 10E 10F
Volume of acid used (mL) 340 340 340 340 340 340
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 13 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 11A 11B 11C 11D 11E 11F
Volume of acid used (mL) 340 340 340 340 340 340
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 14 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 12A 12B 12C 12D 12E 12F
Volume of acid used (mL) 340 340 340 340 340 340
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 15 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 13A 13B 13C 13D 13E 13F
Volume of acid used (mL) 420 420 420 420 420 420
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 16 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 14A 14B 14C 14D 14E 14F
Volume of acid used (mL) 420 420 420 420 420 420
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 17 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 15A 15B 15C 15D 15E 15F
Volume of acid used (mL) 420 420 420 420 420 420
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 18 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 16A 16B 16C 16D 16E 16F
Volume of acid used (mL) 420 420 420 420 420 420
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 19 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 17A 17B 17C 17D 17E 17F
Volume of acid used (mL) 420 420 420 420 420 420
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 20 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 18A 18B 18C 18D 18E 18F
Volume of acid used (mL) 420 420 420 420 420 420
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 21 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 1A 1B 1C 1D 1E 1F
Volume of acid used (mL) 330 330 330 330 330 330
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 22 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 2A 2B 2C 2D 2E 2F
Volume of acid used (mL) 330 330 330 330 330 330
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 23 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 3A 3B 3C 3D 3E 3F
Volume of acid used (mL) 330 330 330 330 330 330
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 24 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 4A 4B 4C 4D 4E 4F
Volume of acid used (mL) 420 420 420 420 420 420
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 25 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 5A 5B 5C 5D 5E 5F
Volume of acid used (mL) 420 420 420 420 420 420
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 26 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 6A 6B 6C 6D 6E 6F
Volume of acid used (mL) 420 420 420 420 420 420
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 27 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 7A 7B 7C 7D 7E 7F
Volume of acid used (mL) 450 450 450 450 450 450
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 28 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 8A 8B 8C 8D 8E 8F
Volume of acid used (mL) 450 450 450 450 450 450
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 29 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 9A 9B 9C 9D 9E 9F
Volume of acid used (mL) 450 450 450 450 450 450
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 30 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 10A 10B 10C 10D 10E 10F
Volume of acid used (mL) 340 340 340 340 340 340
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 31 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 11A 11B 11C 11D 11E 11F
Volume of acid used (mL) 340 340 340 340 340 340
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 32 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 12A 12B 12C 12D 12E 12F
Volume of acid used (mL) 340 340 340 340 340 340
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 33 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 13A 13B 13C 13D 13E 13F
Volume of acid used (mL) 420 420 420 420 420 420
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 34 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 14A 14B 14C 14D 14E 14F
Volume of acid used (mL) 420 420 420 420 420 420
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 35 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 15A 15B 15C 15D 15E 15F
Volume of acid used (mL) 420 420 420 420 420 420
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 36 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 16A 16B 16C 16D 16E 16F
Volume of acid used (mL) 420 420 420 420 420 420
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 37 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 17A 17B 17C 17D 17E 17F
Volume of acid used (mL) 420 420 420 420 420 420
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 38 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 18A 18B 18C 18D 18E 18F
Volume of acid used (mL) 420 420 420 420 420 420
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS Note: mL = Millilitres NA = Not applicable LT = Less than ND = Not detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 39 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
SPECIMEN DESCRIPTION:
Specimen No. Specimen Description Location
1 White printed dull white ceramic Interior of mug (356 – white style)
2 Black printed dull white ceramic Interior of mug (356 – black style)
3 Blue printed dull white ceramic Interior of mug (356 – cobalt style)
4 Dull white printed dull white ceramic Interior of mug (517 – white style)
5 Dull black printed dull white ceramic Interior of mug (517 – black style)
6 Dull blue printed dull white ceramic Interior of mug (517 – cobalt style)
7 Matt white printed dull white ceramic Interior of mug (728 – white style)
8 Matt black printed dull white ceramic Interior of mug (728 – black style)
9 Matt blue printed dull white ceramic Interior of mug (728 – cobalt style)
10 Off white printed dull white ceramic Interior of mug (729 – white style)
11 Off black printed dull white ceramic Interior of mug (729 – black style)
12 Off blue printed dull white ceramic Interior of mug (729 – cobalt style)
13 Bright white printed dull white ceramic Interior of mug (730 – white style)
14 Bright black printed dull white ceramic Interior of mug (730 – black style)
15 Bright blue printed dull white ceramic Interior of mug (730 – cobalt style)
16 Sharp white printed dull white ceramic Interior of mug (767 – white style)
17 Sharp black printed dull white ceramic Interior of mug (767 – black style)
18 Sharp blue printed dull white ceramic Interior of mug (767 – cobalt style)
The above test(s) is/are accredited under the laboratory’s ISO/IEC 17025 accreditation issued by the ANSI‐ASQ National Accreditation Board (ANAB)according to certificate and scope of accreditation (Certificate # AT‐1500.) Test(s) marked with ‘#’ is/are not covered under the scope of accreditation.
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
ANAB is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 16H-00606
Recipient: Rebecca Williams Date of Issue: February 26, 2016
Recipient Email: [email protected] Pages: Page 40 of 40
cc to Email: - Date Received: February 11, 2016
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.05CS-HK-RE005
SAMPLE PHOTO:
-End Report-