ARKEL Vision Setup and User Manual V14

Embed Size (px)

Citation preview

  • 8/11/2019 ARKEL Vision Setup and User Manual V14

    1/18

    ARKEL VisionARL-500 Remote Control and Monitoring System

    Setup and User Manual

  • 8/11/2019 ARKEL Vision Setup and User Manual V14

    2/18

    2

    CONTENTS

    1. Introduction ............................................................................................................................ 3

    2.

    Installation Steps ..................................................................................................................... 3

    2.1.

    Installation of Remote Connection Module .................................................................................................. 3

    2.2.

    Installation of PC Windows software (ARKEL Vision)............................................................................ 6

    2.3. Installation of Network Enabler Administrator software........................................................................... 6

    2.4. Configuring the ARKEL-ETCM remote connection module................................................................... 6

    2.5. Configuring your network equipment (modem / firewall) ....................................................................... 11

    2.6. Defining your ETCM board in ARKEL Vision ......................................................................................... 12

    3.

    Using the ARKEL Vision .................................................................................................. 14

  • 8/11/2019 ARKEL Vision Setup and User Manual V14

    3/18

    3

    1. Introduction

    TheARKEL Vision enables the user to monitor anARL-500 controlled elevator via Internet or LAN

    from remote locations and in case of need, gives the ability to modify its parameters.

    2. Installation Steps

    The ARL-500 Remote Control & Monitoring System consists of these main components:

    1. An ARL-500 Lift Control Panel

    2. AnARKEL ETCMremote connection module

    3. A personal computer running on Windows XP or Vista operating System

    4. A local area network Ethernet connection node (i.e. a modem)

    2.1.

    Installation of Remote Connection Module

    2.1.1. ETCM remote connection module

    ETCM remote connection module contains required components for internet/LAN

    connection. The connection to ARL-500 control panel is made via CANbus. And the

    connection to internet or LAN is made with only an ethernet cable from ETCM module to

    network device.

    The overview of the system is shown in Fig.1a. for an Internet connection, and in Fig. 1b.

    for a local area network connection.

    CAN-0: CANbusconnection plug

    NET: Network

    connection plug

    DIPswitches

    Reset button

  • 8/11/2019 ARKEL Vision Setup and User Manual V14

    4/18

    4

    2.1.2.

    Internet connection

    Fig. 1a: Internet connection

    CAT5

  • 8/11/2019 ARKEL Vision Setup and User Manual V14

    5/18

    5

    2.1.3.

    Local area network connection

    Fig. 1b: Local area network connection

    CAT5

  • 8/11/2019 ARKEL Vision Setup and User Manual V14

    6/18

    6

    2.2. Installation of PC Windows software (ARKEL Vision)

    - Please download theARKEL Visionsoftware setup file from ARKEL website.

    - Open the contents of package to a local folder in your computer.

    - Run setup.exe

    -

    Follow on-screen instructions to install the software.

    2.3. Installation of Network Enabler Administrator software

    -

    Please download theNetwork Enabler Administratorfile from ARKEL website.

    - Open the contents of package to a local folder in your computer.

    -

    Run the setup file

    - Follow on-screen instructions to install the software.

    2.4.

    Configuring the ARKEL-ETCM remote connection module

    The ETCMboard works as a TCP server. It must be assigned a static IP and a TCP port

    number to listen for connections.

    Assigning a static IP and TCP port to the ETCM board:

    Your network specialist must first decide a suitable IP number and a TCP port number to be

    assigned to yourETCMboard. (In this document, we suppose the IP number 192.168.1.13

    and port number 4001 will be used as an example)

    Before configuration, the ETCM board must be connected to the network and powered. Also

    the DIP switches must be set to configuration mode position. For this, please follow these

    steps:

    1. Connect the socket indicated by CAN-0to the ARL-500 Controller Car-CANbus by the

    supplied CANbus cable.

    2. Connect the socket indicated byNET to your ethernet switch,hub or modem by a

    standard ethernet cable. When connected properly, the 10M or the 100M led should light

    up depending on your ethernet speed.

    3. To go into configuration mode, move all 4 DIP-switches onETCMto ON position

    (up). And press the Reset button on ETCM.

    4. The 5 leds on the ETCM board (CPU, CON, RDY, CAN0, CAN1) should start to blink.

    This means that the ETCM board is in configuration mode.

    To assign the IP (192.168.1.13 in our example) to theETCMboard, you will need to use the

    Network Enabler Administratorsoftware which was installed in 2.3. (Start / Programs /

    Network Enabler Administrator / Network Enabler Administrator)

  • 8/11/2019 ARKEL Vision Setup and User Manual V14

    7/18

    7

    When first launched, you will see the following screen:

    Click on Configuration / Broadcast search menu item:

  • 8/11/2019 ARKEL Vision Setup and User Manual V14

    8/18

    8

    If theETCMboard is connected properly, it will be discovered by the software as in the

    following picture:

    If more thanone ETCM are being used, Network Enabler Administrator lists all of the

    network enablers. Code numbers listed in the "MAC Address" column are written on the

    ETCM boards also. You can determine the specific ETCM board via these codes.

    Select the discoveredETCMboard and click Configuration / Configure menu item.

  • 8/11/2019 ARKEL Vision Setup and User Manual V14

    9/18

    9

    Select the Network tab and make the following changes:

    - Click on Modify checkbox above the IP Address textbox and enter 192.168.1.13 in

    the textbox.

    - Click on Modify checkbox under the IP Address textbox and enter the local IP address

    of your modem in the Gateway textbox. (In this example IP number 192.168.1.1 is used).

    Select the Operating Mode tab, click on Modify and select Port-1 in the list. Then

    click the Settings button.

  • 8/11/2019 ARKEL Vision Setup and User Manual V14

    10/18

    10

    Enter the TCP port number (4001 in our example) to the Local TCP Port textbox. Do not

    change the other settings.

    Click OK buttons twice and you will see the following message: Configuration is

    applied OK

    Now, to exit configuration mode, move all 4 DIP switches to OFF position (down). And

    press the Reset button onETCMboard.

  • 8/11/2019 ARKEL Vision Setup and User Manual V14

    11/18

    11

    2.5. Configuring your network equipment (modem / firewall)

    If theETCMboard will be used only inside your network (LAN), it is sufficient to assign it a

    static internal IP number and a TCP port number.

    If it will be accessed from Internet (out of your LAN), your modem and firewall must also

    be configured so as to allow and redirect the incoming TCP traffic from the specific port(port 4001 in our example) to the internal IP of theETCMboard.

    This is usually done from the configuration console supplied by your modem, usually under

    the items NAT (network address translation) settings or Port forwarding settings.

    Please note: As the configuration of every modem differs from each other,

    ARKEL cannot give support about the details of configuration of your specific

    modem / firewall. You will need to contact a network specialist or the

    manufacturer of your modem to get support on configuring your modem and

    firewall.

    How to test your network configuration:

    To check if your modem / firewall is configured properly, you can use the following

    procedure (for Windows XP):

    - Click Start / Run

    -

    Enter cmd in the textbox and click OK

    - In the command screen, type telnet 192.168.1.13 4001 and press enter.

    When you press enter, if the screen goes blank and there are no messages on the screen, your

    network configuration is done properly.

    If you receive the message Connecting 192.168.1.13Unable to connect to host:

    Connection refused, you must review your modem / firewall connections.

    In case the above mentioned network connection test passes but you still have no

    connection, please check the following settings from Network Enabler Administrator:

    Serial settings page:

    Baud rate: 57600

    Parity: None

    Data bits: 8

    Stop bits: 1Flow control: None

    FIFO: Disabled

  • 8/11/2019 ARKEL Vision Setup and User Manual V14

    12/18

    12

    2.6. Defining your ETCM module in ARKEL Vision

    ARKEL Visioncan connect to multiple ETCM boards simultaneously. But to be able to

    connect, it must be given the IP number and TCP port number. The following steps describe

    how to accomplish this:

    Launch theARKEL Visionby clicking Start > Programs > Arkel > ARKEL Vision > StartARKEL Vision.

    You will see the following screen:

    The window on the left is the list of defined elevators. At first run, there is only one item

    Sample Elevator Setting in the list. It is only added as an example and you can delete it byright-clicking and clicking Delete.

  • 8/11/2019 ARKEL Vision Setup and User Manual V14

    13/18

    13

    To add your own elevators to the list, click on the New Elevator button and fill in the

    textboxes as in the following screenshot.. Then click Save.

    Note:The password 12345BCA must be entered in the password field. It will be mademodifiable from ARL-500 menu in the next release. Currently, the password is not

    modifiable.

    When you click on the Save button, your elevator will be added to the list:

    Now your elevator is ready to be monitored.

  • 8/11/2019 ARKEL Vision Setup and User Manual V14

    14/18

    14

    3.Using the ARKEL Vision

    TheARKEL Visioncan connect to multipleETCMboards at the same time. After adding your

    specificETCMboards in the Elevators List as described in 2.6, double-click on the elevator

    item that you want to connect.

    A child window will be opened as shown below:

    Click on the Connect button to connect.

    When a connection is established, the progress bar in the bottom-right corner of the window will

    start to fill. (If the connection cannot be established for the first time, please try again a few

    times as the board resets itself in regular intervals when not connected and is unresponsive

    during the moments of reset)

  • 8/11/2019 ARKEL Vision Setup and User Manual V14

    15/18

    15

    - The Remote Control tab for monitoring and commanding the ARL-500 remotely:

    ARL-500 LCD screen

    ARL-500 keypad

    Special button

  • 8/11/2019 ARKEL Vision Setup and User Manual V14

    16/18

    16

    - The Monitoring tab to see information about the elevator:

    Position indicator

    General purpose inputs

    on ETCM module

    General purpose relayson ETCM module

    Elevator status

    Hall callsCar calls (Clickable)

    Door side A

    Door side B

  • 8/11/2019 ARKEL Vision Setup and User Manual V14

    17/18

    17

    - The Errors tab to see information about the last 200 errors:

  • 8/11/2019 ARKEL Vision Setup and User Manual V14

    18/18

    18

    Publisher ARKEL Elektrik Elektronik Ticaret Ltd. ti.

    Bostanci Yolu ehit Sok. No:36 Yukari Dudullu Istanbul TURKIYE

    TEL : (+90 216) 540 03 10 - 11 -12

    Fax : (+90 216) 540 03 09

    E-mail : [email protected]

    www.arkel.com.tr

    Issue Date 2010

    Document Version V1.4