36
Direct Burial Floodlight 35 - 175 Watt H.I.D. / 42 - 120 Watt PL ARCHITECTURAL FLOOD DBF

ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

  • Upload
    ngokien

  • View
    227

  • Download
    3

Embed Size (px)

Citation preview

Page 1: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

D i r e c t B u r i a lF l o o d l i g h t

35 - 175 Wat t H . I .D. / 42 - 120 Wat t PL

ARCHITECTURAL FLOOD

DBF

Page 2: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

SITE / AREAPARKING STRUCTURE

ROADWAYARCHITECTURAL FLOOD

ACCENTLANDSCAPE

MAILING ADDRESS:P.O. BOX 60080

CITY OF INDUSTRY, CA91716-0080

BUSINESS ADDRESS:16555 EAST GALE AVENUE

CITY OF INDUSTRY, CA 91745U.S.A.

PHONE 626 / 968 - 5666FAX 626 / 369 - 2695

ENTIRE CONTENTS © COPYRIGHT 2011 KIM LIGHTING INC.

ALL RIGHTS RESERVEDREPRODUCTION IN WHOLE OR IN PART

WITHOUT PERMISSION IS STRICTLY PROHIBITED.U.S. PATENT D535,775

www.kimlighting.com

Printed in U.S.A.5507211200

Version 1.2 (7/19/11)

Hubbell Lighting, Inc.

Table of Contents

Two Basic Configurations 1

Applications 2-3

Mechanical Features 4

Optical Features 5

Virtual Performance Models 6-10

Product Structure 11

Ordering Information 12-13

Luminaire Specifications 14

Option Specifications 15

Installation Guide 16

Beam Spread Data 17-19

Photometric Guide 20

Photometrics 21-29

Lamp and Electrical Guide 30-31

References 33

DBF

Direct Burial Floodlight

The Direct Burial Floodlight (DBF)is a new Kim innovation,combining the features of in-grade accent lights withabove-grade floodlights. The KimDBF offers full floodlight opticalsystems in an architecturalhousing designed to project thelowest possible profile abovegrade. As such, the DBF offers afloodlighting solution for sensitivearchitectural designs whereabove-grade floodlights woulddetract from the purity of thebuilding and site. Using thetechnology developed for Kim’srenowned Lightvault below-grade luminaires, the DBF uses acomposite housing for maximumbelow-grade durability and seal integrity. The above-gradehousing is heavy cast bronze or aluminum and contains 9 optical systems from Kim’s celebrated ArchitecturalFloodlight product line.

Page 3: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

WideFlood

VerticalFlood

MediumFlood

NarrowFlood

Spot NarrowSpot

HorizontalSpot

Spot Grazer

HorizontalGrazer

Two Basic Configurations

9 Light Distributions

KIM LIGHTING 1

45°

9090°

20°

9090°90°

45°

4545°45°Fixed Lens Angle

0° Nominal OpticalAiming Angle

45° Nominal Optical Aiming Angle: ±20°

4545°45°

20°

20°

90°90°

4545°45°

45°

45° Nominal OpticalAiming Angle

FixedLens Angle

0° Nominal Optical Aiming Angle: +5°, -20°

Page 4: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

2 KIM LIGHTING

ApplicationDBF11-1745° Nominal Optical Aiming Angle

20°

20° 90°

4545°45°4545°45°

45° Nominal OpticalAiming Angle

FixedLens Angle

45°

With a nominal optical aiming angle of 45°, DBF11-17models are for mounting away from the building tocreate floodlighting effects. Minimum setback fromthe building should be 6' for DBF11-14 “flood”models, while much greater setbacks will berequired for DBF15-17 “spot” models. For smallsigns, a ≤6' setback could be used. See pages 6-9for examples.

Page 5: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

KIM LIGHTING 3

ApplicationDBF18 and DBF19

0° Nominal Optical Aiming Angle

20°

9090°90°

45°45°

FixedLens Angle

4545°45°

0° Nominal OpticalAiming Angle

With a nominal optical aiming angle of 0° (straight up),DBF18 and 19 models are for mounting close to thebuilding to create grazing and highlighting effects.Setbacks, usually only 2' to 5', should bedetermined in relation to reliefs and projections onthe building facade and whether light should fall onthose features. See page 10 for examples.

Page 6: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

Mechanical Features

4 KIM LIGHTING

Bronze or Aluminum Above-grade HousingsRugged one-piece, heavy-wallcastings are used for the above-grade housing and lens frame.Bronze housing is natural, andwill weather to a deep bronzecolor. Aluminum housing isfinished with Super TGICPowder Coat.

Optional Grout MaskA galvanized steel Grout Mask isavailable to aid fixture installationin paved surfaces or a concretepad. Grout Mask is tied intorebar and supports the fixtureduring concrete pour. Seepages 15 and 16.

Anti-siphon BarriersAll wires entering and exiting theballast compartment passthrough anti-siphon barriers.This prevents any moisture fromseeping into the ballast area through the wiring. Each anti-siphon barrier is a one-piece molded and threadedplug installed at the factory.

Composite Below-gradeHousingFor maximum corrosionresistance, the below-gradehousing is compression-molded, high-temperature, fiberglassimpregnated composite. Captivebrass inserts are molded in toreceive the lens frame screws.Two L" NPT conduit entries areprovided in the bottom.

External AimingTo provide the specifier or ownerwith true visual aiming ability, theDBF has been engineered withan external aiming feature. This means that fine-tuning ofthe lighting effect can be achieved at night, with thefixture energized and anyoptional attachments in position.Removing a waterproof plug ontop of the housing accesses theaiming mechanism. An allenwrench is inserted into the housing and aimingadjustments are made whilevisually observing the changesin the lighting effect on the targetsurface or building feature.When aiming is complete, justre-insert the waterproof plug toseal the housing. The plug istethered to the housing toprevent accidental loss whenremoved.

Page 7: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

Optional Lexan® SLX LensShield and Fixed HoodsFor additional side-glare control,a Fixed Hood or Full Shield isavailable. These glare controldevices may only be used withthe DBF11-17, as they willinterfere with the straight-up lightthrow from the DBF18 and 19.For vandal-prone areas, theoptional Lexan® SLX Lens Shieldcan be added and used inaddition to the Fixed Hood or Full Shield.

Optical Features

KIM LIGHTING 5

Color FiltersKim color filters are constructed ofcolor media material sandwichedbetween two sheets of temperedglass, sealed around all edges.The filter is held 2" away from thefixture lens by an extrudedaluminum holder. Available in 5 colors. See pages 13 and 15.

Nine Optical SystemsThe DBF is available in nineoptical configurations rangingfrom wide flood to narrow spot.For the DBF11-17 (45° nominalaiming), all reflectors are fromKim’s AFL10 series of ArchitecturalFloodlights. For the DBF18 and19 (0° nominal aiming), newreflectors have been engineeredfor this configuration. All 9reflectors are self-containedmodules, fully interchangeablewithin the common housing.Each module is retained in the housing by quick-releasehinges, and all wires have quick-disconnect plugs.

45° Nominal Aiming: ±20°

0° Nominal Aiming: +5°, -20°

Page 8: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

Virtual Performance Models

6 KIM LIGHTING

DBF11Wide Flood

Lamp: 175MHSetback: 7'

Aiming: 45°

NOTE: This optical system has the greatest horizontal light throw. To uniformly light the illustrated wall, two fixtures would normally beused, and possibly a higher aiming angle to place more light at thetop of the wall.

ArchitectureThe building created for theseperformance models is strictlyfor the purpose of showing thelighting effects of all 9 DBFmodels on one structure. It is acombination of geometricshapes and textures thatsimulate the various elementsthat are often found inarchitecture. By creating a singlebuilding for all 9 DBF opticalsystems, it is easier to comparethe differences between theindividual lighting effects. Thebuilding facade is divided intoleft and right sides, separated bya cone element. The left side is atextured wall with variouselements that allow flood, spot,or grazing effects to beillustrated. The right side hasthree columns supporting anoverhang to show the lightingeffect on structural elements andrecessed spaces. To create afinished lighting effect on thisbuilding, multiple fixtures wouldnormally be used.

87'

24'

AimingDBF11-14 45°DBF15-17 55°DBF18-19 0°

Setback

DBF11-14 Setback 7'

DBF15-17 Setback 15'

DBF18-19 Setback 2'

43'

Lighting EffectsThe lighting effects in thefollowing nine illustrations are notrenderings, but actual computergenerated effects derived fromreal photometric data. Eachillustration was created by a 3Ddesign, modeling, and animationprogram capable of readingactual I.E.S. photometric filesfrom each DBF fixture. The illustrations are veryaccurate and represent abreakthrough technology by KimLighting in helping specifiersvisualize and apply the complexart of floodlighting.

Page 9: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

KIM LIGHTING 7

DBF13Medium Flood

Lamp: 175MHSetback: 7'

Aiming: 45°

NOTE: The Medium Flood optical system has less horizontal throw,but is more intense. By increasing the setback to 14'±, the wall couldbe uniformly illuminated with two fixtures. However, the lighting effecton the wall would be flatter, showing less texture than the DBF11Wide Flood at a 7' setback.

DBF12Vertical Flood

Lamp: 175MHSetback: 7'

Aiming: 45°

NOTE: The vertical emphasis of this optical system can easily beseen by the higher light level at the top of the wall. However, thismodel has a narrower horizontal light throw. Consequently, threefixtures could be required to uniformly light the wall, but a muchhigher overall light level would be created.

Page 10: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

Virtual Performance Models

8 KIM LIGHTING

DBF15Spot

Lamp: 175MHSetback: 15'

Aiming: 45°

NOTE: The Spot optical system is not designed to floodlight walls. It is intended for highlighting building elements or signage within itsaiming range of 45° ±20°.

DBF14Narrow Flood

Lamp: 175MHSetback: 7'

Aiming: 45°

NOTE: This optical system is slightly narrower than the MediumFlood, but more intense. Like the Medium Flood, the setback couldbe increased to light the wall with two fixtures, but the lighting effecton the wall would be flat, showing very little texture.

Page 11: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

KIM LIGHTING 9

DBF17Horizontal Spot

Lamp: 175MHSetback: 15'

Aiming: 45°

NOTE: The Horizontal Spot projects a long narrow beam for lightinghorizontal signage or building features. In this Illustration, increasingthe aiming angle would highlight the building top, if that were thedesired effect.

DBF16Narrow Spot

Lamp: 175MHSetback: 15'

Aiming: 45°

NOTE: The Narrow Spot is a very intense beam, much narrower thanthe Spot, but intended for the same applications. This optical systemhas internal louvers to restrict spill light, as seen by the dark walloutside of the main beam compared to the Spot.

Page 12: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

Virtual Performance Models

10 KIM LIGHTING

DBF19Horizontal Grazer

Lamp: 175MHSetback: 2'

Aiming: 0° (Straight up)

NOTE: This optical system is for creating maximum texture, andhighlights on walls and building features. It can also be used forlighting the under side of building overhangs. The optical system issimilar to the DBF17 Horizontal Spot, only for straight up aiming.

DBF18Spot Grazer

Lamp: 175MHSetback: 2'

Aiming: 0° (Straight up)

NOTE: This optical system is for creating dramatic highlights onbuilding features. It is designed for mounting close to the structure,creating a high level of texture and contrast.

Page 13: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

Product Structure

DBF

KIM LIGHTING 11

Wide Flood DBF11

Vertical Flood

DBF12

Medium Flood

DBF13

Narrow Flood

DBF14Spot

DBF15

Narrow Spot

DBF16Horizontal Spot

DBF17

Optional Grout Mask GM-4

Optional Lexan® SLX Lens Shield

(May be used with Full Shield or Fixed Hood)

DBF-LS

Optional Color Filter Assembly CFA4-XX

Optional Fixed Hood DBF-FH

Horizontal Grazer DBF19

Spot Grazer DBF18

DBF18 and 19 AluminumDBF718 and 719 Bronze0° Nominal Optical Aiming Angle

DBF11-17 AluminumDBF711-717 Bronze45° Nominal Optical Aiming Angle

4545°45°4545°45°9090°90°

Optional Full Shield DBF-FS

Page 14: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

Options

DBF-FH/BL-P6-10

Ordering Information

Direct Burial Floodlight

12 KIM LIGHTING

2 Electrical Module:HPS = High Pressure Sodium

MH = Metal Halide

PMH = Pulse Start Metal Halide

PL = Fluorescent

Lamp Lamp LineWatts Type Volts175 MH 277

1 Fixture:Cat. No. designates completefixture and beam pattern.“7” designates bronze above-grade housing.

39PMH120 50PMH120 70PMH120 100PMH120 150PMH120 175MH12039PMH208 50PMH208 70PMH208 100PMH208 150PMH208 175MH20839PMH240 50PMH240 70PMH240 100PMH240 150PMH240 175MH24039PMH277 50PMH277 70PMH277 100PMH277 150PMH277 175MH27739PMH347 50PMH347 70PMH347 100PMH347 150PMH347 175MH347

70PMH4801 100PMH4801 150PMH4801 175MH4801

35HPS120 50HPS120 70HPS120 100HPS120 150HPS120 42PL2,3

35HPS277 50HPS208 70HPS208 100HPS208 150HPS20850HPS240 70HPS240 100HPS240 150HPS24050HPS277 70HPS277 100HPS277 150HPS277

70HPS347 100HPS347 150HPS34770HPS4801 100HPS4801 150HPS4801

Ordering Example:

1 Check with local codes for the use of medium base socket with 480 volt.2 Operates 42 watt compact fluorescent lamp. 120 through 277 volt / 50 or 60 Hz.3 Available in wide flood only (DBF11 or DBF711). Operates 120 through 277 volt / 50 or 60 Hz.4 Optional Electronic Ballast is variable voltage ballast for use in 120 through 277 voltages and 50 or 60 Hz.For use with Metal Halide lamps only. Consult factory for other voltages.

20°20°

90°90°4545°45°

20°

5°9090°9090°90°

45°

DBF11-17DBF711-71745° Nominal Aiming

DBF12 AluminumDBF712 BronzeVertical Flood

DBF13 AluminumDBF713 BronzeMedium Flood

DBF14 Aluminum DBF714 BronzeNarrow Flood

DBF15 AluminumDBF715 BronzeSpot

DBF16 AluminumDBF716 BronzeNarrow Spot

DBF17 AluminumDBF717 BronzeHorizontal Spot

DBF18 AluminumDBF718 BronzeSpot Grazer

DBF19 AluminumDBF719 BronzeHorizontal Grazer

DBF18 and 19DBF718 and 7190° Nominal Aiming

DBF711Beam PatternBronze Above-GradeHousing

DBF11Beam PatternAluminum Above-GradeHousing

DBF11 AluminumDBF711 BronzeWide Flood

Optional OptionalFixture Electrical Module Socket Finish Fuse

DBF15 / 175MH277 / G12 / BL-P / SF1 2 3 4 5

Standard Fixture and Options Ordered Assembled with Fixture Options Ordered and Shipped Separately from Fixture

Available with optionalElectronic Ballast. Add E toElectrical Module number.e.g.: 150PMH277E4

Page 15: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

KIM LIGHTING 13

3 Optional Socket:

4 Finish: Aluminum Color: Black Dark Bronze Light Gray Platinum Silver White Custom Colors2

Above-Grade Cat. No.: BL-P DB-P LG-P PS-P WH-P CC-PHousing1: 1Finish: Super TGIC powder coat paint over clear anodizing and Titanated Zirconium

conversion coating.2Consult representative for custom colors.

Bronze Cat. No.: NB Will rapidly age to a rich deep bronze color, and may Above-Grade Natural Bronze develop areas of verde patina.Housing

6 Optional Fixed Hood:Specify Finish for Aluminum HoodExample: DBF-FH/BL-P

Copper Hood has natural finish,and will age to a deep bronze color.May develop areas of verde patina.Example: DBF7-FH

7 Optional Full Shield:Specify Finish for Aluminum HoodExample: DBF-FS/BL-P

Copper Hood has natural finish,and will age to a deep bronze color.May develop areas of verde patina.

Example: DBF7-FS

9 Optional Color FilterAssembly:Specify Finish Example: CFA4-05/BL-P

8 Optional Lexan® SLXLens Shield:

10 Optional Grout Mask:

Cat. No.: G12 Optional G12 base socket is available for 39, 70, and 150 Metal Halide T-6 Bipin lamps.Must use UV filtering lamp.

Cat. No.: DBF-FH Formed 3⁄32" thick aluminum. Mounts to predrilled Aluminum doorframe holes. Cannot be used with DBF18 and DBF19.

Ordered and shipped separately from fixture.

Cat. No.: DBF7-FH Formed A" thick copper. Mounts to predrilled Copper doorframe holes. Cannot be used with DBF718 and DBF719.

Ordered and shipped separately from fixture.

Cat. No.: DBF-LS F" clear convex vacuum formed non-yellowing Clear Finish Lexan® SLX with gasket. Mounts over lens to predrilled

door frame holes and may be used with FH Fixed Hood or FS Full Shield option. Ordered and shipped separately fromfixture.

Cat. No.: GM-4 For fixture support during concrete pour. Galvanized steel guard and rebar. Ties to paving rebar and provides 2" of space for finishing up to fixture. Fixture must be with groutmask during pour. Ordered and shipped separately from fixture. See pages 15 and 16 for details.

Cat. No.: DBF-FS Formed 3⁄32" thick aluminum. Mounts to predrilled doorframeAluminum holes. Should not be used with DBF11 and DBF12.

Use Fixed Hood instead. Cannot be used withDBF18 and DBF19. Ordered and shipped separately fromfixture.

Cat. No.: DBF7-FS Formed A" thick copper. Mounts to predrilled Copper doorframe holes. Should not be used with DBF711 and

DBF712. Use Fixed Hood instead. Cannot be used withDBF718 and DBF719. Ordered and shipped separately fromfixture.

5 Optional Fusing:

Single Fuse

Line Volts: 120V 208V 240V 277V 347V 480VCat. No.: SF DF DF SF SF DF

Cat. No.: CFA4-XX

Color Filter Assembly Cat. No.includes color filter andchannel finish. Specify filter,substituting XX for color filternumber (See below) and addfinish.

Color Filter: Deep Straw Rose Tint Medium Red Brilliant Blue Primary Green

XX: 15 05 27 69 91

Heavy wall aluminum extrusion with anti-reflection baffles andvertical channels that hold the color filter 2" away from thefixture lens. Quick change-out of the color filter is possible bythe removal of two channel screws. Support mounts topredrilled holes in fixture door frame. May be used inconjunction with FH Fixed Hood or FS Full Shield option.Ordered and shipped separately from fixture.

High temperature fuse holders factory installed inside thefixture housing. Single Fusing (SF) for 120V, 277V and 347Vor Double Fusing (DF) for 208V, 240V and 480V.

Page 16: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

Luminaire Specifications

Direct Burial Floodlight

14 KIM LIGHTING

Above-Grade Housing: One-piece cast aluminum or bronze. Six captive M" blackened stainless steel hex-socket cap screwsattach housing to composite body. One-piece high temperaturesilicone gasket seals housing to composite body.

Lens Frame: One-piece cast aluminum or bronze. Six captive J" blackened stainless steel hex-socket cap screws attach lens frameto housing. One-piece molded high temperature silicone gasket.

Lens: F" impact resistant clear tempered glass enclosed by a one-piece high temperature silicone gasket.

Below-Grade Housing: High temperature, compression molded,fiberglass impregnated, F" min. wall composite. Charcoal gray. No top lip to trap dirt and moisture. Solid brass knurled insertsmolded-in to receive above-grade housing screws. Separate spliceand ballast compartments with individual cast aluminum internalcovers with silicone gaskets. Two L" NPT in bottom for throughwiring, 45 cu in. splice area. Housing supplied with protective plasticmask for clean and easy installation in concrete pad or soil.

Reflector Assemblies: Interchangeable in all models. Specularaluminum optical components mounted to aluminum frame.Reflector assembly snaps into fixture housing with spring clips andis adjustable from outside through a sealed access hole. Socketsare 4KV porcelain medium base for H.I.D. (G12 base socketoptional); Plastic four-pin socket for Fluorescent. Fluorescent is onlyavailable with wide flood reflector (DBF11 and DBF711).

Electrical Module: Electromagnetic H.I.D. ballast shall be highpower factor, -20°F starting. Electronic H.I.D. ballast shall be highpower factor, low frequency electronic, -20°F starting. Fluorescentballast shall be high power factor, 0°F starting, electronic ballast.Ballast shall be factory pre-wired and mounted to ballastcompartment cover.

Wiring: Anti-siphon barriers on all wiring to and from ballastcompartment and lamp compartment. All components wire linkedfor ground, quick disconnect for removal of optical system.

Finish: Cast aluminum housing and lens frame are finished in SuperTGIC thermoset polyester powder coat over clear anodizing.Standard colors are Black, Dark Bronze, Light Gray, Platinum Silver,or White. Powder coating is 2.5-mil nominal thickness, and allcomponents are thoroughly cleaned and primed with a TitanatedZirconium conversion coating prior to powder coating. Cast bronzehousing and lens frame finish shall be natural as cast.

Fixture Assembly: IP68 rated to be completely protected from dustand water from all directions.

4545°45°

45° Nominal OpticalAiming Angle

0° Nominal OpticalAiming Angle

FixedLens Angle

4545°45°FixedLens Angle

45°

17B"

7E"

6"

3" 17B"

3"13E"

10C"

13L"

(2) L" NPT

14C"

14K"

13"

20°

20°

20°5°

9090°9090°90°

4545°45°

Above-grade

Below-grade

Dimensions

DBF11-17, 45° Nominal Optical Aiming Angle

DBF18 and 19, 0° Nominal Optical Aiming Angle

Listings and RatingsUL cUL 1598 25C AmbientIP68 Rated CE ISO 9001:2000

CAUTION: Fixtures must be grounded in accordance with national,state, and/or local electrical codes. Failure to do so may result inserious personal injury.

Page 17: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

Option Specifications

See pages 12-13 for complete ordering information

KIM LIGHTING 15

Color Filter Assembly (CFA4-XX): Heavy wall aluminum extrusionwith anti-reflection baffles and vertical channels that hold the colorfilter 2" away from the fixture lens. Quick change-out of the color filteris possible by the removal of two channel screws. Support mounts topredrilled holes in fixture door frame. May be used with FH FixedHood or FS Full Shield option.Color Filter Assembly includes color filter.Sample Color1 XX Filter # 2 Description

Deep Straw 15 Warms metal halide color. Deepens high pressure sodium color to yellow/orange.

Rose Tint 05 Warms metal halide color. Deepens high pressure sodium color to pink/orange.

Medium Red 27 Deep color accent. Best used with high pressure sodium lamps.NOTE: Very low output with metal halide lamps.

Brilliant Blue 69 Deep color accent. Best used with metal halide lamps. NOTE: Not recommended for high pressure sodium lamps.

Primary Green 91 Deep color accent. Blue shift with metal halide lamps. Yellow shift with highpressure sodium lamps.

NOTE: Color samples shown for reference only and will not represent actual illumination color rendered by H.I.D. lamps.1 Exact color output is highly dependent on lamp used, (i.e. HPS vs. MH, specific lamp color temperature and other factors).2 XX Color filter number corresponds with Roscolux color filter numbers.

Optional Fixed Hood:Cat. No. DBF-FH: Formed 3⁄32" thick aluminum. Mounts to predrilleddoorframe holes. Cannot be used with DBF18 and DBF19. Orderedand shipped separately from fixture. Finish: Super TGIC thermosetpolyester powder coat.Cat. No. DBF7-FH: Formed A" thick copper. Mounts to predrilleddoorframe holes. Cannot be used with DBF718 and DBF719.Ordered and shipped separately from fixture. Finish: Natural copper.

Optional Full Shield:Cat. No. DBF-FS: Formed 3⁄32" thick aluminum. Mounts to predrilleddoorframe holes. Cannot be used with DBF18 and DBF19. Orderedand shipped separately from fixture. Finish: Super TGIC thermosetpolyester powder coat.Cat. No. DBF7-FS: Formed A" thick copper. Mounts to predrilleddoorframe holes. Cannot be used with DBF718 and DBF719.Ordered and shipped separately from fixture. Finish: Natural copper.

Optional Lexan® SLX Lens Shield (DBF-LS): F" clear convexvacuum formed non-yellowing Lexan® SLX with gasket. Mounts overlens to predrilled door frame holes and may be used with Fixed Hoodor Full Shield option. Ordered and shipped separately from fixture.

Optional Grout Mask (GM-4): For fixture support during concretepour. Galvanized steel guard and rebar. Ties to paving rebar andprovides 2" of space for finishing up to fixture. Fixture must be withgrout mask during pour. Ordered and shipped separately fromfixture.

14C" 4"

9K"

14C" 5"

9K"

14C"

9K"

2"

18"21

12C"

13J"

13D"

Page 18: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

Installation Guide

16 KIM LIGHTING

Rock fill2" to 4"

above grade

Buffer ZoneRedwood or other material for edging.

2" to 4"

above gradeRock fill

Concrete InstallationConcrete must have reinforcing rods to preventcracking from fixture heat expansion.

Encase entirehousing inConcrete

Paved Area InstallationOptional grout mask supportsfixture during concrete pour.

Tie groutmask torebar forsupport.

2" grout spacefor finishing.

Advantages• Prevents lens overgrowth.• Provides a defined edge for

trimming.• Provides drainage away from

the lens to maintain lightoutput.

• Visually looks like a flushinstallation.

Advantages• Cleaner, more stable installation,

less susceptible to traffic andmaintenance activity.

• Prevents lens overgrowth.• Provides a defined edge for

trimming.• Provides drainage away from

the lens to maintain lightoutput.

• Visually looks like a flushinstallation.

Advantages• Supports fixture at proper

height during concrete pour.• Provides 2" grout space for

finishing.• Easily adapts to any paving

material; concrete, brick,stone, etc.

Create a Buffer ZoneWhen fixtures are located in areas planted in ground cover or shrubbery, construct a buffer zone to prevent lens overgrowth and to create anedge for trimming. Elevate thefixtures for drainage and backfillwith decorative rock. As theground cover grows, the fixtureswill look flush even though theyare 2" to 4" above grade.

Install in ConcreteAnother option for installations inground cover, shrubbery or lawnareas is to encase the fixture inconcrete. This creates the bufferzone as described above, withthe additional advantage ofgreater fixture stability. Elevatethe fixture 2" to 4" above grade,and slope the concrete awayfrom the housing for drainage.

In Paved AreasWhen below-grade luminairesare installed in paving, it isusually required that the below-grade housing be flushwith finished grade. To make thisinstallation easier, Kim offers anoptional Grout Mask (page 15)to support the housing at theproper height during theconcrete pour. The Grout Maskis normally tied into the pavingrebar for support.

NOTE: Always use adequate rebar surrounding the fixture to preventcracking of the concrete due to heat expansion.

Wiring and AssemblyAfter installing conduit and pulling the correct conductors into thesplice compartment, seal the conduit by injecting silicone sealer intothe open conduit end to completely block the entry of water.Clean all gaskets, cover plates, housing flanges, and housinginterior. Install gaskets, cover plates, and housings as outlined in theInstallation Instructions. Install lamp and test for operation.Energize the fixture. Allow the fixture to reach operating temperature(at least 30 minutes). Remove aiming plug and allow the fixture to“Breathe” for approximately 10 minutes; this will permit the moist airto be “Exhaled”. While the fixture is still energized, replace theaiming plug and tighten as described in the Installation Instructions.This procedure should be repeated each time the fixture is openedfor maintenance.

Isolate and Elevate.The fundamentals of a clean, maintainable installation.

Lens Frame and HousingBolt Tightening Sequence

15

62

3 4

15

62

3 4

Seal conduit atentry with RTVto prevent moisturefrom entering throughconduit system

Ballast Compartment

Ballast CompartmentCover

Above-Grade Housing

Lens Frame

Splice Compartment

Below-Grade Housing

Conduit (by others)

Anti-siphon Barriers

Page 19: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

KIM LIGHTING 17

Beam Spread Data

1 All Initial Lumen values shown are approximate and may vary from one manufacturer to another as well as one operating position to another. Consult lampmanufacturer’s data for exact lumen and life data.

2 Beam Angle: Horizontal and vertical beam spreads interpolated due to no valid I.E.S. standard.3 Field Angle: Horizontal and vertical beam spreads interpolated due to no valid I.E.S. standard.

DBF12 Vertical Flood Beam Spread ChartLamp

Lamp Initial I.E.S. Maximum Field Angle3 Beam Angle2 PhotometricWatts Lumens1 Type Candlepower (10% of max.) (50% of max.) Test No.

35HPS ED-17 clear med. base 35 2250 6H x 5V 1137 (3.0 x 11.0) 121.9 x 96.2 77.3 x 39.0 KL0049350HPS ED-17 clear med. base 50 4000 6H x 5V 2021 (3.0 x 11.0) 121.9 x 96.2 77.3 x 39.0 KL0049270HPS ED-17 clear med. base 70 6300 6H x 5V 3182 (3.0 x 11.0) 121.9 x 96.2 77.3 x 39.1 KL00491100HPS ED-17 clear med. base 100 9500 6H x 5V 4799 (3.0 x 11.0) 121.9 x 96.2 77.3 x 39.0 KL00403150HPS ED-17 clear med. base 150 16000 6H x 5V 7586 (3.0 x 13.0) 123.3 x 98.9 79.2 x 59.4 KL00515

39MH T-6 clear G-12 base 39 3400 6H x 5V 1629 (0.0 x 11.0) 124.1 x 99.8 78.7 x 44.7 KL0048750MH ED-17 clear med. base 50 4000 6H x 5V 2062 (1.0 x 11.0 125.0 x 99.2 82.9 x 70.4 KL0049070MH ED-17 clear med. base 70 5900 6H x 5V 3041 (1.0 x 11.0) 125.0 x 99.2 82.9 x 70.3 KL00489100MH ED-17 clear med. base 100 8800 6H x 5V 4536 (1.0 x 11.0) 125.0 x 99.2 82.9 x 70.3 KL00391150MH ED-17 clear med. base 150 12600 6H x 6V 5415 (3.0 x 7.0) 124.9 x 100.8 84.7 x 76.0 KL00400175MH ED-17 clear med. base 175 12800 6H x 6V 5501 (3.0 x 7.0) 124.9 x 100.8 84.7 x 76.0 KL00343

HIGH PRESSURE SODIUM

METAL HALIDE

DBF13 Medium Flood Beam Spread ChartLamp

Lamp Initial I.E.S. Maximum Field Angle Beam Angle2 PhotometricWatts Lumens1 Type Candlepower (10% of max.) (50% of max.) Test No.

35HPS ED-17 clear med. base 35 2250 7H x 6V 662 (47.5 x 13.0) 148.3 x 125.2 133.9 x 77.1 KL0055650HPS ED-17 clear med. base 50 4000 7H x 6V 1177 (47.5 x 13.0) 148.4 x 125.2 133.9 x 77.1 KL0055570HPS ED-17 clear med. base 70 6300 7H x 6V 1854 (47.5 x 13.0) 148.4 x 125.2 133.9 x 77.1 KL00554100HPS ED-17 clear med. base 100 9500 7H x 6V 2795 (47.5 x 13.0) 148.3 x 125.2 133.9 x 77.1 KL00508150HPS ED-17 clear med. base 150 16000 7H x 6V 7384 (42.5 x 0.0) 145.3 x 116.9 111.7 x 48.5 KL00369

39MH T-6 clear G-12 base 39 3400 7H x 6V 983 (47.5 x -19.5) 148.6 x 127.7 134.5 x 79.5 KL0047550MH ED-17 clear med. base 50 4250 7H x 6V 1330 (47.5 x -15.0) 148.1 x 126.1 132.2 x 74.4 KL0055370MH ED-17 clear med. base 70 6200 7H x 6V 1941 (47.5 x -15.0) 148.1 x 126.2 132.2 x 74.4 KL00552100MH ED-17 clear med. base 100 9300 7H x 6V 2911 (47.5 x -15.0) 148.1 x 126.1 132.2 x 74.4 KL00417150MH ED-17 clear med. base 150 14000 7H x 6V 3965 (47.5 x -11.0) 148.2 x 127.1 131.5 x 79.5 KL00551175MH ED-17 clear med. base 175 14400 7H x 6V 4078 (47.5 x -11.0) 148.2 x 127.1 131.5 x 79.5 KL00426

HIGH PRESSURE SODIUM

METAL HALIDE

DBF14 Narrow Flood Beam Spread ChartLamp

Lamp Initial I.E.S. Maximum Field Angle Beam Angle2 PhotometricWatts Lumens1 Type Candlepower (10% of max.) (50% of max.) Test No.

35HPS ED-17 clear med. base 35 2250 7H x 6V 937 (5.0 x -3.0) 143.8 x 113.6 103.1 x 45.9 KL0056250HPS ED-17 clear med. base 50 4000 7H x 6V 1667 (5.0 x -3.0) 143.8 x 113.6 103.1 x 45.9 KL0056170HPS ED-17 clear med. base 70 6300 7H x 6V 2625 (5.0 x -3.0) 143.8 x 113.6 103.1 x 45.9 KL00560100HPS ED-17 clear med. base 100 9500 7H x 6V 3958 (5.0 x -3.0) 143.8 x 113.6 103.1 x 45.9 KL00507150HPS ED-17 clear med. base 150 16000 7H x 6V 7003 (22.5 x -7.0) 141.9 x 108.9 102.3 x 46.6 KL00370

39MH T-6 clear G-12 base 39 3400 7H x 6V 1738 (5.0 x -9.0) 141.5 x 109.4 89.6 x 34.1 KL0047750MH ED-17 clear med. base 50 4250 7H x 6V 1974 (5.0 x -5.0) 143.2 x 110.1 100.8 x 40.1 KL0055970MH ED-17 clear med. base 70 6200 7H x 6V 2880 (5.0 x -5.0) 143.2 x 110.1 100.8 x 40.1 KL00558100MH ED-17 clear med. base 100 9300 7H x 6V 4320 (5.0 x -5.0) 143.2 x 110.1 100.8 x 40.1 KL00418150MH ED-17 clear med. base 150 14000 7H x 6V 5685 (7.0 x -5.0) 144.3 x 119.2 109.7 x 50.0 KL00557175MH ED-17 clear med. base 175 14400 7H x 6V 5847 (7.0 x -5.0) 144.3 x 119.2 109.7 x 50.0 KL00423

HIGH PRESSURE SODIUM

METAL HALIDE

DBF11 Wide Flood Beam Spread ChartLamp

Lamp Initial I.E.S. Maximum Field Angle Beam Angle2 PhotometricWatts Lumens1 Type Candlepower (10% of max.) (50% of max.) Test No.

35HPS ED-17 clear med. base 35 2250 7H x 7V 579 (47.5 x -15.0) 160 x 138.5 139.5 x 94.5 KL0055050HPS ED-17 clear med. base 50 4000 7H x 7V 1029 (47.5 x -15.0) 160 x 138.5 139.5 x 94.5 KL0054970HPS ED-17 clear med. base 70 6300 7H x 7V 1620 (47.5 x -15.0) 160 x 138.5 139.5 x 94.5 KL00548100HPS ED-17 clear med. base 100 9500 7H x 7V 2443 (47.5 x-15.0) 160 x 138.5 139.5 x 94.5 KL00509150HPS ED-17 clear med. base 150 16000 7H x 6V 4444 (47.5 x -13.0) 148.8 x 126 135.3 x 80.3 KL00544

39MH T-6 clear G-12 base 39 3400 7H x 7V 846 (47.5 x -13.0) 163.1 x 144.2 141.3 x 102.5 KL0047650MH ED-17 clear med. base 50 4250 7H x 6V 1293 (47.5 x -15.0) 147.9 x 125.5 131.5 x 73.0 KL0054770MH ED-17 clear med. base 70 6200 7H x 6V 1887 (47.5 x -15.0) 147.9 x 125.5 131.5 x 73.0 KL00546100MH ED-17 clear med. base 100 9300 7H x 6V 2830 (47.5 x -15.0) 147.9 x 125.5 131.5 x 73.0 KL00543150MH ED-17 clear med. base 150 14000 7H x 6V 4285 (47.5 x -13.0) 148.5 x 127.0 133.5 x 79.6 KL00545175MH ED-17 clear med. base 175 14400 7H x 6V 4407 (47.5 x -13.0) 148.5 x 127.0 133.5 x 79.6 KL00542

42PL PL-T coated GX24q-4 42 3200 7H x 7V 815 (47.5 x -17.0) 157.0 x 139.6 131.1 x 86.8 KL00464

HIGH PRESSURE SODIUM

METAL HALIDE

FLUORESCENT

Page 20: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

18 KIM LIGHTING

Beam Spread Data

DBF15 Spot Beam Spread ChartLamp

Lamp Initial I.E.S. Maximum Field Angle Beam Angle2 PhotometricWatts Lumens1 Type Candlepower (10% of max.) (50% of max.) Test No.

35HPS ED-17 clear med. base 35 2250 3H x 3V 5188 (0.0 x 3.0) 45.9 x 30.1 21.7 x 13.3 KL0056850HPS ED-17 clear med. base 50 4000 3H x 3V 9223 (0.0 x 3.0) 45.9 x 30.1 21.7 x 13.3 KL0056770HPS ED-17 clear med. base 70 6300 3H x 3V 14526 (0.0 x 3.0) 45.9 x 30.1 21.7 x 13.3 KL00566100HPS ED-17 clear med. base 100 9500 3H x 3V 21904 (0.0 x 3.0) 45.9 x 30.1 21.7 x 13.3 KL00510150HPS ED-17 clear med. base 150 16000 5H x 4V 21337 (1.0 x 1.0) 79.1 x 52.6 28.1 x 24.2 KL00372

39MH T-6 clear G-12 base 39 3400 3H x 2V 10695 (1.0 x -5.0) 45.8 x 21.4 19.8 x 9.3 KL0047150MH ED-17 clear med. base 50 4250 3H x 2V 11706 (0.0 x 0.0) 43.4 x 23.6 22.5 x 11.6 KL0056570MH ED-17 clear med. base 70 6200 3H x 2V 17077 (0.0 x 0.0) 43.4 x 23.6 22.5 x 11.6 KL00564100MH ED-17 clear med. base 100 9300 3H x 2V 25615 (0.0 x 0.0) 43.4 x 23.6 22.5 x 11.6 KL00419150MH ED-17 clear med. base 150 14000 3H x 3V 31464 (0.0 x 0.0) 42.9 x 33.9 23.8 x 14.5 KL00563175MH ED-17 clear med. base 175 14400 3H x 3V 32363 (0.0 x 0.0) 42.9 x 33.9 23.8 x 14.5 KL00424

1 All Initial Lumen values shown are approximate and may vary from one manufacturer to another as well as one operating position to another. Consult lampmanufacturer’s data for exact lumen and life data.

2 Beam Angle: Horizontal and vertical beam spreads interpolated due to no valid I.E.S. standard.

HIGH PRESSURE SODIUM

METAL HALIDE

DBF16 Narrow Spot Beam Spread ChartLamp

Lamp Initial I.E.S. Maximum Field Angle Beam Angle2 PhotometricWatts Lumens1 Type Candlepower (10% of max.) (50% of max.) Test No.

35HPS ED-17 clear med. base 35 2250 1H x 2V 11406 (0.0 x 7.0) 16.8 x 26.3 10.6 x 13.5 KL0057450HPS ED-17 clear med. base 50 4000 1H x 2V 20277 (0.0 x 7.0) 16.8 x 26.3 10.6 x 13.5 KL0057370HPS ED-17 clear med. base 70 6300 1H x 2V 31937 (0.0 x 7.0) 16.8 x 26.3 10.6 x 13.5 KL00572100HPS ED-17 clear med. base 100 9500 1H x 2V 48159 (0.0 x 7.0) 16.8 x 26.3 10.6 x 13.5 KL00511150HPS ED-17 clear med. base 150 16000 1H x 3V 111233 (0.0 x 3.0) 13.2 x 31.4 5.5 x 14.7 KL00436

39MH T-6 clear G-12 base 39 3400 1H x 1V 73712 (0.0 x 5.0) 12.2 x 11.0 6.7 x 5.6 KL0047950MH ED-17 clear med. base 50 4250 1H x 1V 75795 (0.0 x 3.0) 9.8 x 17.9 4.8 x 8.7 KL0057170MH ED-17 clear med. base 70 6200 1H x 1V 110572 (0.0 x 3.0) 9.8 x 17.9 4.8 x 8.7 KL00570100MH ED-17 clear med. base 100 9300 1H x 1V 165858 (0.0 x 3.0) 9.8 x 17.9 4.8 x 8.7 KL00420150MH ED-17 clear med. base 150 14000 1H x 1V 138750 (0.0 x 3.0) 13.9 x 24.8 6.2 x 12.8 KL00569175MH ED-17 clear med. base 175 14400 1H x 2V 142714 (0.0 x 3.0) 13.9 x 24.8 6.2 x 12.8 KL00360

HIGH PRESSURE SODIUM

METAL HALIDE

DBF17 Horizontal Spot Beam Spread ChartLamp

Lamp Initial I.E.S. Maximum Field Angle Beam Angle2 PhotometricWatts Lumens1 Type Candlepower (10% of max.) (50% of max.) Test No.

35HPS ED-17 clear med. base 35 2250 6H x 5V 2372 (0.0 x 5.0) 107.2 x 89.6 75.0 x 9.1 KL0057750HPS ED-17 clear med. base 50 4000 6H x 5V 4216 (0.0 x 5.0) 107.2 x 89.6 75.0 x 9.1 KL0057670HPS ED-17 clear med. base 70 6300 6H x 5V 6640 (0.0 x 5.0) 107.2 x 89.6 75.1 x 9.1 KL00575100HPS ED-17 clear med. base 100 9500 6H x 5V 10013 ( 0.0 x 5.0) 107.2 x 89.6 75.0 x 9.1 KL00512150HPS ED-17 clear med. base 150 16000 6H x 5V 19425 (1.0 x 3.0) 103.3 x 85.9 74.0 x 7.2 KL00377

39MH T-6 clear G-12 base 39 3400 6H x 5V 3970 (1.0 x 3.0) 105.4 x 82.6 76.3 x 8.4 KL0048550MH ED-17 clear med. base 50 4000 6H x 5V 4909 (1.0 x 3.0) 107.8 x 85.3 76.9 x 7.6 KL0049870MH ED-17 clear med. base 70 5900 6H x 5V 7240 (1.0 x 3.0) 107.9 x 85.3 76.9 x 7.6 KL00497100MH ED-17 clear med. base 100 8800 6H x 5V 10799 (1.0 x 3.0) 107.9 x 85.3 76.9 x 7.6 KL00392150MH ED-17 clear med. base 150 12600 6H x 5V 12334 (0.0 x 1.0) 106.9 x 89.7 80.1 x 11.8 KL00401175MH ED-17 clear med. base 175 12800 6H x 5V 12530 (0.0 x 1.0) 106.9 x 89.7 80.1 x 11.8 KL00347

HIGH PRESSURE SODIUM

METAL HALIDE

DBF18 Spot Grazer Beam Spread ChartLamp

Lamp Initial I.E.S. Maximum Field Angle Beam Angle2 PhotometricWatts Lumens1 Type Candlepower (10% of max.) (50% of max.) Test No.

35HPS ED-17 clear med. base 35 2250 1H x 3V 8052 (0.0 x 47.5) 16.1 x 31.7 9.3 x 17.9 KL0045450HPS ED-17 clear med. base 50 4000 1H x 3V 14315 (0.0 x 47.5) 16.1 x 31.7 9.3 x 17.9 KL0044170HPS ED-17 clear med. base 70 6300 1H x 3V 22547 (0.0 x 47.5) 16.1 x 31.7 9.3 x 17.9 KL00437100HPS ED-17 clear med. base 100 9500 1H x 3V 33999 (0.0 x 47.5) 16.1 x 31.7 9.3 x 17.9 KL00371150HPS ED-17 clear med. base 150 16000 1H x 3V 66200 (0.0 x 47.5) 13.0 x 33.4 6.5 x 19.5 KL00375

39MH T-6 clear G-12 base 39 3400 1H x 1V 49146 (1.0 x 47.5) 9.9 x 15.4 5.7 x 7.2 KL0036750MH ED-17 clear med. base 50 4000 1H x 2V 30524 (0.0 x 42.5) 12.4 x 18.2 6.9 x 11.6 KL0042270MH ED-17 clear med. base 70 5900 1H x 2V 45023 (0.0 x 42.5) 12.4 x 18.2 6.9 x 11.6 KL00421100MH ED-17 clear med. base 100 8800 1H x 2V 67153 (0.0 x 42.5) 12.4 x 18.2 6.9 x 11.6 KL00359150MH ED-17 clear med. base 150 12600 1H x 2V 52380 (1.0 x 42.5) 16.8 x 26.4 8.6 x 13.4 KL00404175MH ED-17 clear med. base 175 12800 1H x 2V 53211 (1.0 x 42.5) 16.8 x 26.4 8.6 x 13.4 KL00350

HIGH PRESSURE SODIUM

METAL HALIDE

Page 21: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

DBF11-17Fixture Setback and Aiming Range on Vertical Surfaces.

KIM LIGHTING 19

Nomina

l Aim

ing A

ngle

20°

20°

45°4545°45°

AA

B

C

D

B

C

D

Pre-planning fixture locations is very important with the Kim DBF11-17 models, particularly setbacks (A). Unlike above-gradefloodlights, the DBF housing is fixed, and aiming is accomplishedby externally adjusting the reflectors ±20° vertically. Therefore, youmust make sure that the target is within the aiming range of thefixture, based on its setback (A). This is far more critical for theDBF15, 16, and 17 due to the narrow beam spreads of the Spot,Narrow Spot, and Horizontal Spot optical systems.

The following table shows the height on the target surface (typicallya wall or sign) that the 45° nominal aiming angle falls (C), and theheight where it would fall if aimed ±20° (B and D), all based on thesetback (A).

Beam Spread Data

NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative.Lamps by others.

CAUTION: Fixtures must be grounded in accordance with national, state, and/or local electrical codes. Failure to do so may result in serious personal injury.

DBF19 Horizontal Grazer Spread ChartLamp

Lamp Initial I.E.S. Maximum Field Angle Beam Angle2 PhotometricWatts Lumens1 Type Candlepower (10% of max.) (50% of max.) Test No.

35HPS ED-17 clear med. base 35 2250 6H x 4V 748 (0.0 x 33.0) 113.0 x 55.0 69.7 x 27.0 KL0049450HPS ED-17 clear med. base 50 4000 6H x 4V 1330 (9.0 x 33.0) 112.9 x 55.0 69.7 x 26.9 KL0048470HPS ED-17 clear med. base 70 6300 6H x 4V 2094 (0.0 x 33.0) 112.9 x 55.0 69.7 x 27.0 KL00478100HPS ED-17 clear med. base 100 9500 6H x 4V 3158 (9.0 x 33.0) 112.9 x 55.0 69.7 x 27.0 KL00399150HPS ED-17 clear med. base 150 16000 6H x 4V 5619 (0.0 x 42.5) 105.3 x 48.4 70.6 x 22.8 KL00378

39MH T-6 clear G-12 base 39 3400 6H x 4V 1568 (0.0 x 37.5) 105.4 x 51.5 62.6 x 12.8 KL0039050MH ED-17 clear med. base 50 4000 6H x 4V 1305 (13.0 x 37.5) 116.7 x 53.9 74.0 x 20.9 KL0046770MH ED-17 clear med. base 70 5900 6H x 4V 1926 (13.0 x 37.5) 116.7 x 53.8 74.0 x 20.9 KL00462100MH ED-17 clear med. base 100 8800 6H x 4V 2872 (13.0 x 37.5) 116.7 x 53.8 74.0 x 20.9 KL00389150MH ED-17 clear med. base 150 12600 6H x 4V 3943 (1.0 x 25.5) 120.6 x 60.8 81.6 x 31.7 KL00455175MH ED-17 clear med. base 175 12800 6H x 4V 4006 (1.0 x 25.5) 120.6 x 60.8 81.6 x 31.7 KL00394

HIGH PRESSURE SODIUM

METAL HALIDE

1 All Initial Lumen values shown are approximate and may vary from one manufacturer to another as well as one operating position to another. Consult lampmanufacturer’s data for exact lumen and life data.

2 Beam Angle: Horizontal and vertical beam spreads interpolated due to no valid I.E.S. standard.

Distances in Feet

A 3 5 7 9 12 15 18 21 25 30 35 40 45 50 55 60 65 70

B 1.40 2.33 3.26 4.20 5.60 6.99 8.39 9.79 11.66 13.99 16.32 18.65 20.98 23.32 25.65 27.98 30.31 32.64

C 3.00 5.00 7.00 9.00 12.00 15.00 18.00 21.00 25.00 30.00 35.00 40.00 45.00 50.00 55.00 60.00 65.00 70.00

D 6.43 10.72 15.01 19.30 25.73 32.17 38.60 45.03 53.61 64.34 75.06 85.78 96.50 107.23 117.95 128.67 139.39 150.12

Page 22: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

Photometric Guide

20 KIM LIGHTING

DBF11-1745° Nominal OpticalAiming AnglePhotometric charts for thesemodels show lines of equalfootcandle values on a verticalsurface, with a selected setbackdistance, and the optical aimingangle. Distances up and alongthe vertical surface are shown.Because the overall light patternis symmetrical in halves, onlyone half is shown for easierreadability.

Legend for OpticsWF - Wide FloodVF - Vertical FloodMF - Medium FloodNF - Narrow FloodSP - SpotNSP - Narrow SpotHSP - Horizontal Spot

Fixture:Optics:

Lamp Mode:

Lamp

10'20'30'40'

50'

30'

40'

2

1.5

.2

.1

.05

10'

20'

I.E.S. Type: 7H x 6V Field Angle: 147.9° x 125.5° (10% of max.) Beam Angle: 131.5° x 73.0° (50% of max.)

6,200 Initial Lumens Test No.: KL00546

ED-17 70W Metal Halide

45° Optical Aiming Angle10' Setback

DBF11 WF70PMH

Footcandle DiagramTypical Half

DBF18 and 190° Nominal Optical Aiming AnglePhotometric charts for thesemodels show lines of equalfootcandle values on a surfacedirectly above the fixture,representing a buildingoverhang. Footcandle lines arenot shown on the vertical surfacebecause the purpose of grazinglight is to create texture andhighlights, which footcandlelines do not depict. Since the overall light pattern issymmetrical in halves, only onehalf is shown for easierreadability.

50'

40'

10'20'30'40'

30'

20'

10'

10521

I.E.S. Type: 1H x 2V Field Angle: 12.4° x 18.2° (10% of max.) Beam Angle: 6.9° x 11.6° (50% of max.)

5,900 Initial Lumens Test No.: KL00421

ED-17 70W Metal Halide

0° Optical Aiming Angle5' Setback

50' Target Distance

DBF18 SPG70PMH

Fixture:Optics:

Lamp Mode:

Lamp

Footcandle DiagramTypical Half

Legend for OpticsSPG - Spot GrazerHG - Horizontal Grazer

Page 23: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

WF - Wide Flood

KIM LIGHTING 21

10'20'30'40'

2

1.5

.2

.1

.05

50'

10'

30'

20'

40'

I.E.S. Type: 7H x 7V Field Angle: 163.1° x 144.2° (10% of max.) Beam Angle: 141.3° x 102.5° (50% of max.)

3,400 Initial Lumens Test No.: KL00476

T-6 Clear G-12 Base 39W Metal Halide

45° Optical Aiming Angle10' Setback

DBF11 WF39PMH

10'20'30'40'

10'

20'

2

1.5

.2.1

.05

50'

30'

40'

I.E.S. Type: 7H x 6V Field Angle: 147.9° x 125.5° (10% of max.) Beam Angle: 131.5° x 73.0° (50% of max.)

4,250 Initial Lumens Test No.: KL00547

ED-17 50W Metal Halide

45° Optical Aiming Angle10' Setback

DBF11 WF50PMH

10'20'30'40'

50'

30'

40'

2

1.5

.2

.1

.05

10'

20'

I.E.S. Type: 7H x 6V Field Angle: 147.9° x 125.5° (10% of max.) Beam Angle: 131.5° x 73.0° (50% of max.)

6,200 Initial Lumens Test No.: KL00546

ED-17 70W Metal Halide

45° Optical Aiming Angle10' Setback

DBF11 WF70PMH

10'20'30'40'

5

21

.5

.2

.1

50'

30'

40'

10'

20'

I.E.S. Type: 7H x 6V Field Angle: 147.9° x 125.5° (10% of max.) Beam Angle: 131.5° x 73.0° (50% of max.)

9,300 Initial Lumens Test No.: KL00543

ED-17 100W Metal Halide

45° Optical Aiming Angle10' Setback

DBF11 WF100PMH

10'20'30'40'

5

2

1

.5

50'

30'

40'

10'

20'

.2

.1

.1

I.E.S. Type: 7H x 6V Field Angle: 148.5° x 127.0° (10% of max.) Beam Angle: 133.5° x 79.6° (50% of max.)

14,000 Initial Lumens Test No.: KL00545

ED-17 150W Metal Halide

45° Optical Aiming Angle10' Setback

DBF11 WF150PMH

10'20'30'40'

5

21

.5

.2

.1

50'

30'

40'

10'

20'

.1

I.E.S. Type: 7H x 6V Field Angle: 148.5° x 127.0° (10% of max.) Beam Angle: 133.5° x 79.6° (50% of max.)

14,400 Initial Lumens Test No.: KL00542

ED-17 175W Metal Halide

45° Optical Aiming Angle10' Setback

DBF11 WF175MH

1

.5

.2

.1

.05

50'

10'

30'

20'

40'

10'20'30'40'

I.E.S. Type: 7H x 7V Field Angle: 160° x 138.5° (10% of max.) Beam Angle: 139.5° x 94.5° (50% of max.)

2,250 Initial Lumens Test No.: KL00550

ED-17 35W HPS

45° Optical Aiming Angle10' Setback

DBF11 WF35HPS

21

.5

.2

.1

.05

50'

10'

30'

20'

40'

10'20'30'40'

I.E.S. Type: 7H x 7V Field Angle: 160° x 138.5° (10% of max.) Beam Angle: 139.5° x 94.5° (50% of max.)

4,000 Initial Lumens Test No.: KL00549

ED-17 50W HPS

45° Optical Aiming Angle10' Setback

DBF11 WF50HPS

2

1.5

.2

.1

50'

10'

30'

20'

40'

10'20'30'40'

I.E.S. Type: 7H x 7V Field Angle: 160° x 138.5° (10% of max.) Beam Angle: 139.5° x 94.5° (50% of max.)

6,300 Initial Lumens Test No.: KL00548

ED-17 70W HPS

45° Optical Aiming Angle10' Setback

DBF11 WF70HPS

5

2

1

.5

.2

.1

50'

10'

30'

20'

40'

10'20'30'40'

I.E.S. Type: 7H x 7V Field Angle: 160° x 138.5° (10% of max.) Beam Angle: 139.5° x 94.5° (50% of max.)

9,500 Initial Lumens Test No.: KL00509

ED-17 100W HPS

45° Optical Aiming Angle10' Setback

DBF11 WF100HPS

10

52

1.5

.2

.1

.1

50'

10'

30'

20'

40'

10'20'30'40'

I.E.S. Type: 7H x 6V Field Angle: 148.8° x 126° (10% of max.) Beam Angle: 135.3° x 80.3° (50% of max.)

16,000 Initial Lumens Test No.: KL00544

ED-17 150W HPS

45° Optical Aiming Angle10' Setback

DBF11 WF150HPS

10'20'30'40'

2

1.5

.2

.1

.05

50'

30'

40'

10'

20'

I.E.S. Type: 7H x 7V Field Angle: 157.0° x 139.6° (10% of max.) Beam Angle: 131.1° x 86.8° (50% of max.)

3,200 Initial Lumens Test No.: KL00464

PL-T Coated GX24q-4 42W Fluorescent

45° Optical Aiming Angle10' Setback

DBF11 WF42PL

DBF11

Page 24: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

DBF12

VF - Vertical Flood

22 KIM LIGHTING

21

.5

.2.1

.05

10'

30'

50'

10'20'30'40'

20'

40'

I.E.S. Type: 6H x 5V Field Angle: 124.1° x 99.8° (10% of max.) Beam Angle: 78.7° x 44.7° (50% of max.)

3,400 Initial Lumens Test No.: KL00487

T-6 Clear G-12 Base 39W Metal Halide

45° Optical Aiming Angle10' Setback

DBF12 VF39PMH

10'

30'

40'

50'

10'20'30'40'

5

21

.5

.2

.1

.05

20'

I.E.S. Type: 6H x 5V Field Angle: 125.0° x 99.2° (10% of max.) Beam Angle: 82.9° x 70.4° (50% of max.)

4,000 Initial Lumens Test No.: KL00490

ED-17 50W Metal Halide

45° Optical Aiming Angle10' Setback

DBF12 VF50PMH

10'

20'

30'

40'

50'

10'20'30'40'

5

21

.5.2

.1.05

I.E.S. Type: 6H x 5V Field Angle: 125.0° x 99.2° (10% of max.) Beam Angle: 82.9° x 70.3° (50% of max.)

5,900 Initial Lumens Test No.: KL00489

ED-17 70W Metal Halide

45° Optical Aiming Angle10' Setback

DBF12 VF70PMH

10

52

1.5

.2

.1

.05

10'

20'

30'

40'

50'

10'20'30'40'

I.E.S. Type: 6H x 5V Field Angle: 125.0° x 99.2° (10% of max.) Beam Angle: 82.9° x 70.3° (50% of max.)

8,800 Initial Lumens Test No.: KL00391

ED-17 100W Metal Halide

45° Optical Aiming Angle10' Setback

DBF12 VF100PMH

105

21

.5

.2

.1.05

10'

20'

30'

40'

50'

10'20'30'40'

I.E.S. Type: 6H x 6V Field Angle: 124.9° x 100.8° (10% of max.) Beam Angle: 84.7° x 76.0° (50% of max.)

12,600 Initial Lumens Test No.: KL00400

ED-17 150W Metal Halide

45° Optical Aiming Angle10' Setback

DBF12 VF150PMH

105

21

.5

.2.1

.05

10'

20'

30'

40'

50'

10'20'30'40'

I.E.S. Type: 6H x 6V Field Angle: 124.9° x 100.8° (10% of max.) Beam Angle: 84.7° x 76.0° (50% of max.)

12,800 Initial Lumens Test No.: KL00343

ED-17 175W Metal Halide

45° Optical Aiming Angle10' Setback

DBF12 VF175MH

10'

30'

50'

10'20'30'40'

2

1.5

.2

.1

.05

20'

40'

I.E.S. Type: 6H x 5V Field Angle: 121.9° x 96.2° (10% of max.) Beam Angle: 77.3° x 39.0° (50% of max.)

2,250 Initial Lumens Test No.: KL00493

ED-17 35W HPS

45° Optical Aiming Angle10' Setback

DBF12 VF35HPS

21

.5

.2

.1

.05

10'

30'

50'

10'20'30'40'

20'

40'

I.E.S. Type: 6H x 5V Field Angle: 121.9° x 96.2° (10% of max.) Beam Angle: 77.3° x 39.0° (50% of max.)

4,000 Initial Lumens Test No.: KL00492

ED-17 50W HPS

45° Optical Aiming Angle10' Setback

DBF12 VF50HPS

5

21

.5.2

.1

.05

10'

30'

50'

10'20'30'40'

20'

40'

I.E.S. Type: 6H x 5V Field Angle: 121.9° x 96.2° (10% of max.) Beam Angle: 77.3° x 39.1° (50% of max.)

6,300 Initial Lumens Test No.: KL00491

ED-17 70W HPS

45° Optical Aiming Angle10' Setback

DBF12 VF70HPS

10

5

2

1

.5

.2

.1

.05

10'

30'

50'

10'20'30'40'

20'

40'

I.E.S. Type: 6H x 5V Field Angle: 121.9° x 96.2° (10% of max.) Beam Angle: 77.3° x 39.0° (50% of max.)

9,500 Initial Lumens Test No.: KL00403

ED-17 100W HPS

45° Optical Aiming Angle10' Setback

DBF12 VF100HPS

20

10

5

21

.5

.2.1

.05

10'

30'

50'

10'20'30'40'

20'

40'

I.E.S. Type: 6H x 5V Field Angle: 123.3° x 98.9° (10% of max.) Beam Angle: 79.2° x 59.4° (50% of max.)

16,000 Initial Lumens Test No.: KL00515

ED-17 150W HPS

45° Optical Aiming Angle10' Setback

DBF12 VF150HPS

Page 25: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

DBF13

MF - Medium Flood

KIM LIGHTING 23

10'20'30'40'

50'

40'

10'

30'

20'

I.E.S. Type: 7H x 6V Field Angle: 148.6° x 127.7° (10% of max.) Beam Angle: 134.5° x 79.5° (50% of max.)

3,400 Initial Lumens Test No.: KL00475

T-6 Clear G-12 Base 39W Metal Halide

45° Optical Aiming Angle10' Setback

DBF13 MF39PMH

21

.5

.2

.1

.05

21

.5

.2

.1

.05

10'20'30'40'

50'

10'

30'

20'

40'

I.E.S. Type: 7H x 6V Field Angle: 148.1° x 126.1° (10% of max.) Beam Angle: 132.2° x 74.4° (50% of max.)

4,250 Initial Lumens Test No.: KL00553

ED-17 50W Metal Halide

45° Optical Aiming Angle10' Setback

DBF13 MF50PMH

10'20'30'40'

50'

30'

40'

21

.5

.2

.1

.05

10'

20'

I.E.S. Type: 7H x 6V Field Angle: 148.1° x 126.2° (10% of max.) Beam Angle: 132.2° x 74.4° (50% of max.)

6,200 Initial Lumens Test No.: KL00552

ED-17 70W Metal Halide

45° Optical Aiming Angle10' Setback

DBF13 MF70PMH

10'20'30'40'

5

21

.5

.2

.1

50'

30'

40'

10'

20'

I.E.S. Type: 7H x 6V Field Angle: 148.1° x 126.1° (10% of max.) Beam Angle: 132.2° x 74.4° (50% of max.)

9,300 Initial Lumens Test No.: KL00417

ED-17 100W Metal Halide

45° Optical Aiming Angle10' Setback

DBF13 MF100PMH

10'20'30'40'

50'

30'

40'

10'

20'

105

21

.5

.2

.1

I.E.S. Type: 7H x 6V Field Angle: 148.2° x 127.1° (10% of max.) Beam Angle: 131.5° x 79.5° (50% of max.)

14,000 Initial Lumens Test No.: KL00551

ED-17 150W Metal Halide

45° Optical Aiming Angle10' Setback

DBF13 MF150PMH

10'20'30'40'

105

2

1

.5

.2

.1

30'

40'

10'

20'

50'

I.E.S. Type: 7H x 6V Field Angle: 148.2° x 127.1° (10% of max.) Beam Angle: 131.5° x 79.5° (50% of max.)

14,400 Initial Lumens Test No.: KL00426

ED-17 175W Metal Halide

45° Optical Aiming Angle10' Setback

DBF13 MF175MH

10'20'30'40'

1

.5

.2

.1

.05

50'

10'

30'

20'

40'

I.E.S. Type: 7H x 6V Field Angle: 148.3° x 125.2° (10% of max.) Beam Angle: 133.9° x 77.1° (50% of max.)

2,250 Initial Lumens Test No.: KL00556

ED-17 35W HPS

45° Optical Aiming Angle10' Setback

DBF13 MF35HPS

2

1.5

.2.1

.05

10'20'30'40'

50'

10'

30'

20'

40'

I.E.S. Type: 7H x 6V Field Angle: 148.4° x 125.2° (10% of max.) Beam Angle: 133.9° x 77.1° (50% of max.)

4,000 Initial Lumens Test No.: KL00555

ED-17 50W HPS

45° Optical Aiming Angle10' Setback

DBF13 MF50HPS

21

.5

.2

.1

.05

10'20'30'40'

50'

10'

30'

20'

40'

I.E.S. Type: 7H x 6V Field Angle: 148.4° x 125.2° (10% of max.) Beam Angle: 133.9° x 77.1° (50% of max.)

6,300 Initial Lumens Test No.: KL00554

ED-17 70W HPS

45° Optical Aiming Angle10' Setback

DBF13 MF70HPS

10'20'30'40'

50'

5

2

1

.5

.2

.1

I.E.S. Type: 7H x 6V Field Angle: 148.3° x 125.2° (10% of max.) Beam Angle: 133.9° x 77.1° (50% of max.)

9,500 Initial Lumens Test No.: KL00508

ED-17 100W HPS

45° Optical Aiming Angle10' Setback

DBF13 MF100HPS

30'

10'

20'

40'

10'20'30'40'

50'

40'

30'

10

5

21

.5

.2

.1

I.E.S. Type: 7H x 6V Field Angle: 145.3° x 116.9° (10% of max.) Beam Angle: 111.7° x 48.5° (50% of max.)

16,000 Initial Lumens Test No.: KL00369

ED-17 150W HPS

45° Optical Aiming Angle10' Setback

DBF13 MF150HPS

10'

20'

Page 26: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

DBF14

NF - Narrow Flood

24 KIM LIGHTING

21

.5

.2

.1

.05

10'

10'20'30'40'

50'

30'

40'

20'

I.E.S. Type: 7H x 6V Field Angle: 141.5° x 109.4° (10% of max.) Beam Angle: 89.6° x 34.1° (50% of max.)

3,400 Initial Lumens Test No.: KL00477

T-6 Clear G-12 Base 39W Metal Halide

45° Optical Aiming Angle10' Setback

DBF14 NF39PMH

10'20'30'40'

10'

50'

30'

40'

20'

21

.5

.2

.1

.05

I.E.S. Type: 7H x 6V Field Angle: 143.2° x 110.1° (10% of max.) Beam Angle: 100.8 x 40.1° (50% of max.)

4,250 Initial Lumens Test No.: KL00559

ED-17 50W Metal Halide

45° Optical Aiming Angle10' Setback

DBF14 NF50PMH

52

1.5

.2

.1

.05

10'20'30'40'

10'

50'

30'

40'

20'

I.E.S. Type: 7H x 6V Field Angle: 143.2° x 110.1° (10% of max.) Beam Angle: 100.8 x 40.1° (50% of max.)

6,200 Initial Lumens Test No.: KL00558

ED-17 70W Metal Halide

45° Optical Aiming Angle10' Setback

DBF14 NF70PMH

10'20'30'40'

10

52

1

.5

.2

.1

.05

10'

50'

30'

40'

20'

I.E.S. Type: 7H x 6V Field Angle: 143.2° x 110.1° (10% of max.) Beam Angle: 100.8 x 40.1° (50% of max.)

9,300 Initial Lumens Test No.: KL00418

ED-17 100W Metal Halide

45° Optical Aiming Angle10' Setback

DBF14 NF100PMH

10'20'30'40'

10'

50'

30'

40'

20'

105

2

1

.5

.2

.1

I.E.S. Type: 7H x 6V Field Angle: 144.3° x 119.2° (10% of max.) Beam Angle: 109.7° x 50.0° (50% of max.)

14,000 Initial Lumens Test No.: KL00557

ED-17 150W Metal Halide

45° Optical Aiming Angle10' Setback

DBF14 NF150PMH

10'20'30'40'

10'

50'

30'

40'

20'

105

2

1

.5

.2

.1

I.E.S. Type: 7H x 6V Field Angle: 144.3° x 119.2° (10% of max.) Beam Angle: 109.7° x 50.0° (50% of max.)

14,400 Initial Lumens Test No.: KL00423

ED-17 175W Metal Halide

45° Optical Aiming Angle10' Setback

DBF14 NF175MH

21.5

.2

.1

.05

50'

10'

30'

20'

40'

10'20'30'40'

I.E.S. Type: 7H x 6V Field Angle: 143.8° x 113.6° (10% of max.) Beam Angle: 103.1° x 45.9° (50% of max.)

2,250 Initial Lumens Test No.: KL00562

ED-17 35W HPS

45° Optical Aiming Angle10' Setback

DBF14 NF35HPS

50'

10'

30'

10'20'30'40'

21

.5

.2

.1

.05

20'

40'

I.E.S. Type: 7H x 6V Field Angle: 143.8° x 113.6° (10% of max.) Beam Angle: 103.1° x 45.9° (50% of max.)

4,000 Initial Lumens Test No.: KL00561

ED-17 50W HPS

45° Optical Aiming Angle10' Setback

DBF14 NF50HPS

10'20'30'40'

52

1

.5

.2

.1

.05

50'

10'

30'

40'

20'

I.E.S. Type: 7H x 6V Field Angle: 143.8° x 113.6° (10% of max.) Beam Angle: 103.1° x 45.9° (50% of max.)

6,300 Initial Lumens Test No.: KL00560

ED-17 70W HPS

45° Optical Aiming Angle10' Setback

DBF14 NF70HPS

10'20'30'40'

50'

30'

40'

20'

10'10

52

1

.5.2

.1

.05

I.E.S. Type: 7H x 6V Field Angle: 143.8° x 113.6° (10% of max.) Beam Angle: 103.1° x 45.9° (50% of max.)

9,500 Initial Lumens Test No.: KL00507

ED-17 100W HPS

45° Optical Aiming Angle10' Setback

DBF14 NF100HPS

10'20'30'40'

50'

30'

40'

20'

10'

I.E.S. Type: 7H x 6V Field Angle: 141.9° x 108.9° (10% of max.) Beam Angle: 102.3° x 46.6° (50% of max.)

16,000 Initial Lumens Test No.: KL00370

ED-17 150W HPS

45° Optical Aiming Angle10' Setback

DBF14 NF150HPS

2010

52

1.5

.2

.1

Page 27: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

DBF15

SP - Spot

KIM LIGHTING 25

10'30'40' 20'

10'

50'

30'

40'

20'52

1

.5.2

.1

I.E.S. Type: 3H x 2V Field Angle: 45.8° x 21.4° (10% of max.) Beam Angle: 19.8° x 9.3° (50% of max.)

3,400 Initial Lumens Test No.: KL00471

T-6 Clear G-12 Base 39W Metal Halide

45° Optical Aiming Angle20' Setback

DBF15 SP39PMH

5

10'30'40' 20'

10'

50'

30'

40'

20'

21.5

.2

.1

I.E.S. Type: 3H x 2V Field Angle: 43.4° x 23.6° (10% of max.) Beam Angle: 22.5° x 11.6° (50% of max.)

4,250 Initial Lumens Test No.: KL00565

ED-17 50W Metal Halide

45° Optical Aiming Angle20' Setback

DBF15 SP50PMH

10'30'40' 20'

10'

50'

30'

40'

20'

52

1

.5

.2

.1

I.E.S. Type: 3H x 2V Field Angle: 43.4° x 23.6° (10% of max.) Beam Angle: 22.5° x 11.6° (50% of max.)

6,200 Initial Lumens Test No.: KL00564

ED-17 70W Metal Halide

45° Optical Aiming Angle20' Setback

DBF15 SP70PMH

10'30'40' 20'

10'

50'

30'

40'

20'

1052

1.5

.2

I.E.S. Type: 3H x 2V Field Angle: 43.4° x 23.6° (10% of max.) Beam Angle: 22.5° x 11.6° (50% of max.)

9,300 Initial Lumens Test No.: KL00419

ED-17 100W Metal Halide

45° Optical Aiming Angle20' Setback

DBF15 SP100PMH

10'30'40' 20'

10'

50'

30'

40'

10521

.5

.2

20'

I.E.S. Type: 3H x 3V Field Angle: 42.9° x 33.9° (10% of max.) Beam Angle: 23.8° x 14.5° (50% of max.)

14,000 Initial Lumens Test No.: KL00563

ED-17 150W Metal Halide

45° Optical Aiming Angle20' Setback

DBF15 SP150PMH

10'30'40' 20'

10'

50'

30'

40'

20'

1052

1.5

.2

I.E.S. Type: 3H x 3V Field Angle: 42.9° x 33.9° (10% of max.) Beam Angle: 23.8° x 14.5° (50% of max.)

14,400 Initial Lumens Test No.: KL00424

ED-17 175W Metal Halide

45° Optical Aiming Angle20' Setback

DBF15 SP175MH

21

.5

.2

.1

10'30'40' 20'

10'

50'

30'

40'

20'

I.E.S. Type: 3H x 3V Field Angle: 45.9° x 30.1° (10% of max.) Beam Angle: 21.7° x 13.3° (50% of max.)

2,250 Initial Lumens Test No.: KL00568

ED-17 35W HPS

45° Optical Aiming Angle20' Setback

DBF15 SP35HPS

10'30'40' 20'

10'

50'

30'

40'

20'

21

.5.2

.1

I.E.S. Type: 3H x 3V Field Angle: 45.9° x 30.1° (10% of max.) Beam Angle: 21.7° x 13.3° (50% of max.)

4,000 Initial Lumens Test No.: KL00567

ED-17 50W HPS

45° Optical Aiming Angle20' Setback

DBF15 SP50HPS

10'30'40' 20'

10'

50'

30'

40'

20'

21

.5.2

5

I.E.S. Type: 3H x 3V Field Angle: 45.9° x 30.1° (10% of max.) Beam Angle: 21.7° x 13.3° (50% of max.)

6,300 Initial Lumens Test No.: KL00566

ED-17 70W HPS

45° Optical Aiming Angle20' Setback

DBF15 SP70HPS

10'30'40' 20'

10'

50'

30'

40'

20'10

5

2

1

.5

.2

I.E.S. Type: 3H x 3V Field Angle: 45.9° x 30.1° (10% of max.) Beam Angle: 21.7° x 13.3° (50% of max.)

9,500 Initial Lumens Test No.: KL00510

ED-17 100W HPS

45° Optical Aiming Angle20' Setback

DBF15 SP100HPS

10'30'40' 20'

10'

50'

30'

40'

20'10

5

21

.5

I.E.S. Type: 5H x 4V Field Angle: 79.1° x 52.6° (10% of max.) Beam Angle: 28.1° x 24.2° (50% of max.)

16,000 Initial Lumens Test No.: KL00372

ED-17 150W HPS

45° Optical Aiming Angle20' Setback

DBF15 SP150HPS

Page 28: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

DBF16

NSP - Narrow Spot

26 KIM LIGHTING

30'40'

70'

10'

60'21

.5

.2

I.E.S. Type: 1H x 1V Field Angle: 12.2° x 11.0° (10% of max.) Beam Angle: 6.7° x 5.6° (50% of max.)

3,400 Initial Lumens Test No.: KL00479

T-6 Clear G-12 Base 39W Metal Halide

45° Optical Aiming Angle40' Setback

DBF16 NSP39PMH

50'

40'

30'

20' 30'40' 20' 10'

70'

50'

30'

60'521

40'

.5

.2

I.E.S. Type: 1H x 1V Field Angle: 9.8° x 17.9° (10% of max.) Beam Angle: 4.8° x 8.7° (50% of max.)

4,250 Initial Lumens Test No.: KL00571

ED-17 50W Metal Halide

45° Optical Aiming Angle40' Setback

DBF16 NSP50PMH

30'40' 20' 10'

70'

50'

30'

60'

40'

.5

21

5

I.E.S. Type: 1H x 1V Field Angle: 9.8° x 17.9° (10% of max.) Beam Angle: 4.8° x 8.7° (50% of max.)

6,200 Initial Lumens Test No.: KL00570

ED-17 70W Metal Halide

45° Optical Aiming Angle40' Setback

DBF16 NSP70PMH

30'40' 20' 10'

70'

50'

30'

60'

40'

1

1052

.5

I.E.S. Type: 1H x 1V Field Angle: 9.8° x 17.9° (10% of max.) Beam Angle: 4.8° x 8.7° (50% of max.)

9,300 Initial Lumens Test No.: KL00420

ED-17 100W Metal Halide

45° Optical Aiming Angle40' Setback

DBF16 NSP100PMH

105

12

30'40' 20' 10'

70'

50'

60'

40'

30'

I.E.S. Type: 1H x 1V Field Angle: 13.9° x 24.8° (10% of max.) Beam Angle: 6.2° x 12.8° (50% of max.)

14,000 Initial Lumens Test No.: KL00569

ED-17 150W Metal Halide

45° Optical Aiming Angle40' Setback

DBF16 NSP150PMH

30'40' 20' 10'

70'

50'

60'

40'

30'

10521

I.E.S. Type: 1H x 2V Field Angle: 13.9° x 24.8° (10% of max.) Beam Angle: 6.2° x 12.8° (50% of max.)

14,400 Initial Lumens Test No.: KL00360

ED-17 175W Metal Halide

45° Optical Aiming Angle40' Setback

DBF16 NSP175MH

30'40'

1.5.2

30'

70'

50'

60'

40'

10'

I.E.S. Type: 1H x 2V Field Angle: 16.8° x 26.3° (10% of max.) Beam Angle: 10.6° x 13.5° (50% of max.)

2,250 Initial Lumens Test No.: KL00574

ED-17 35W HPS

45° Optical Aiming Angle40' Setback

DBF16 NSP35HPS

20' 30'40' 20'

30'

70'

50'

60'

40'

10'

21

.5

.2

I.E.S. Type: 1H x 2V Field Angle: 16.8° x 26.3° (10% of max.) Beam Angle: 10.6° x 13.5° (50% of max.)

4,000 Initial Lumens Test No.: KL00573

ED-17 50W HPS

45° Optical Aiming Angle40' Setback

DBF16 NSP50HPS

30'40' 20'

30'

70'

50'

60'

40'

10'

21.5.2

I.E.S. Type: 1H x 2V Field Angle: 16.8° x 26.3° (10% of max.) Beam Angle: 10.6° x 13.5° (50% of max.)

6,300 Initial Lumens Test No.: KL00572

ED-17 70W HPS

45° Optical Aiming Angle40' Setback

DBF16 NSP70HPS

30'40' 20'

30'

70'

40'

10'

60'

50'

2

.51

I.E.S. Type: 1H x 2V Field Angle: 16.8° x 26.3° (10% of max.) Beam Angle: 10.6° x 13.5° (50% of max.)

9,500 Initial Lumens Test No.: KL00511

ED-17 100W HPS

45° Optical Aiming Angle40' Setback

DBF16 NSP100HPS

30'40' 20'

30'

70'

50'

40'

10'

60'

10521

.5

I.E.S. Type: 1H x 3V Field Angle: 13.2° x 31.4° (10% of max.) Beam Angle: 5.5° x 14.7° (50% of max.)

16,000 Initial Lumens Test No.: KL00436

ED-17 150W HPS

45° Optical Aiming Angle40' Setback

DBF16 NSP150HPS

Page 29: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

DBF17

HSP - Horizontal Spot

KIM LIGHTING 27

50'

10'

30'

10'20'30'40'

20'

40'

1.5

.2

I.E.S. Type: 6H x 5V Field Angle: 105.4° x 82.6° (10% of max.) Beam Angle: 76.3° x 8.4° (50% of max.)

3,400 Initial Lumens Test No.: KL00485

T-6 Clear G-12 Base 39W Metal Halide

45° Optical Aiming Angle20' Setback

DBF17 HSP39PMH

50'

10'

30'

10'20'30'40'

20'

40'

I.E.S. Type: 6H x 5V Field Angle: 107.8° x 85.3° (10% of max.) Beam Angle: 76.9° x 7.6° (50% of max.)

4,000 Initial Lumens Test No.: KL00498

ED-17 50W Metal Halide

45° Optical Aiming Angle20' Setback

DBF17 HSP50PMH

1.5

.2

50'

10'

30'

10'20'30'40'

20'

40'

21

.5

.2

I.E.S. Type: 6H x 5V Field Angle: 107.9° x 85.3° (10% of max.) Beam Angle: 76.9° x 7.6° (50% of max.)

5,900 Initial Lumens Test No.: KL00497

ED-17 70W Metal Halide

45° Optical Aiming Angle20' Setback

DBF17 HSP70PMH

50'

10'

30'

10'20'30'40'

20'

40'

21

.5

.2

I.E.S. Type: 6H x 5V Field Angle: 107.9° x 85.3° (10% of max.) Beam Angle: 76.9° x 7.6° (50% of max.)

8,800 Initial Lumens Test No.: KL00392

ED-17 100W Metal Halide

45° Optical Aiming Angle20' Setback

DBF17 HSP100PMH

50'

10'

30'

10'20'30'40'

20'

40'

52

1.5

.2

I.E.S. Type: 6H x 5V Field Angle: 106.9° x 89.7° (10% of max.) Beam Angle: 80.1° x 11.8° (50% of max.)

12,600 Initial Lumens Test No.: KL00401

ED-17 150W Metal Halide

45° Optical Aiming Angle20' Setback

DBF17 HSP150PMH

50'

10'20'40'

5

.5

.2

21

10'

30'

20'

40'

ED-17 175W Metal Halide

45° Optical Aiming Angle20' Setback

I.E.S. Type: 6H x 5V Field Angle: 106.9° x 89.7° (10% of max.) Beam Angle: 80.1° x 11.8° (50% of max.)

12,800 Initial Lumens Test No.: KL00347

DBF17 HSP175MH

30'

50'

10'

30'

10'20'30'40'

20'

40'

.5

.2.1

I.E.S. Type: 6H x 5V Field Angle: 107.2° x 89.6° (10% of max.) Beam Angle: 75.0° x 9.1° (50% of max.)

2,250 Initial Lumens Test No.: KL00577

ED-17 35W HPS

45° Optical Aiming Angle20' Setback

DBF17 HSP35HPS

50'

10'

30'

10'20'30'40'

20'

40'

1

.5

.2

I.E.S. Type: 6H x 5V Field Angle: 107.2° x 89.6° (10% of max.) Beam Angle: 75.0° x 9.1° (50% of max.)

4,000 Initial Lumens Test No.: KL00576

ED-17 50W HPS

45° Optical Aiming Angle20' Setback

DBF17 HSP50HPS

50'

10'

30'

10'20'30'40'

20'

40'

1

.5.2

I.E.S. Type: 6H x 5V Field Angle: 107.2° x 89.6° (10% of max.) Beam Angle: 75.1° x 9.1° (50% of max.)

6,300 Initial Lumens Test No.: KL00575

ED-17 70W HPS

45° Optical Aiming Angle20' Setback

DBF17 HSP70HPS

50'

10'

30'

10'20'30'40'

20'

40'

21

.5

.2

I.E.S. Type: 6H x 5V Field Angle: 107.2° x 89.6° (10% of max.) Beam Angle: 75.0° x 9.1° (50% of max.)

9,500 Initial Lumens Test No.: KL00512

ED-17 100W HPS

45° Optical Aiming Angle20' Setback

DBF17 HSP100HPS

50'

10'

30'

10'20'30'40'

20'

40'

5

21

.5

.2

I.E.S. Type: 6H x 5V Field Angle: 103.3° x 85.9° (10% of max.) Beam Angle: 74.0° x 7.2° (50% of max.)

16,000 Initial Lumens Test No.: KL00377

ED-17 150W HPS

45° Optical Aiming Angle20' Setback

DBF17 HSP150HPS

Page 30: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

DBF18

SPG - Spot Grazer

28 KIM LIGHTING

10'20'30'40'

5

2

1.5

50'

40'

30'

20'

10'

I.E.S. Type: 1H x 1V Field Angle: 9.9° x 15.4° (10% of max.) Beam Angle: 5.7° x 7.2° (50% of max.)

3,400 Initial Lumens Test No.: KL00367

T6 Clear G-12 Base39W Metal Halide

0° Optical Aiming Angle5' Setback

50' Target Distance

DBF18 SPG39PMH

52

1

10'20'30'40'

50'

40'

30'

20'

10'

I.E.S. Type: 1H x 2V Field Angle: 12.4° x 18.2° (10% of max.) Beam Angle: 6.9° x 11.6° (50% of max.)

4,000 Initial Lumens Test No.: KL00422

ED-17 50W Metal Halide

0° Optical Aiming Angle5' Setback

50' Target Distance

DBF18 SPG50PMH

50'

40'

10'20'30'40'

30'

20'

10'

10521

I.E.S. Type: 1H x 2V Field Angle: 12.4° x 18.2° (10% of max.) Beam Angle: 6.9° x 11.6° (50% of max.)

5,900 Initial Lumens Test No.: KL00421

ED-17 70W Metal Halide

0° Optical Aiming Angle5' Setback

50' Target Distance

DBF18 SPG70PMH

105

21

10'20'30'40'

50'

40'

30'

20'

10'

I.E.S. Type: 1H x 2V Field Angle: 12.4° x 18.2° (10% of max.) Beam Angle: 6.9° x 11.6° (50% of max.)

8,800 Initial Lumens Test No.: KL00359

ED-17 100W Metal Halide

0° Optical Aiming Angle5' Setback

50' Target Distance

DBF18 SPG100PMH

10

52

1

10'20'30'40'

50'

40'

30'

20'

10'

I.E.S. Type: 1H x 2V Field Angle: 16.8° x 26.4° (10% of max.) Beam Angle: 8.6° x 13.4° (50% of max.)

12,600 Initial Lumens Test No.: KL00404

ED-17 150W Metal Halide

0° Optical Aiming Angle5' Setback

50' Target Distance

DBF18 SPG150PMH

10

52

1

10'20'30'40'

50'

40'

30'

20'

10'

I.E.S. Type: 1H x 2V Field Angle: 16.8° x 26.4° (10% of max.) Beam Angle: 8.6° x 13.4° (50% of max.)

12,800 Initial Lumens Test No.: KL00350

ED-17 175W Metal Halide

0° Optical Aiming Angle5' Setback

50' Target Distance

DBF18 SPG175MH

21

10'20'30'40'

50'

40'

30'

20'

10'

I.E.S. Type: 1H x 3V Field Angle: 16.1° x 31.7° (10% of max.) Beam Angle: 9.3° x 17.9° (50% of max.)

2,250 Initial Lumens Test No.: KL00454

ED-17 35W HPS

0° Optical Aiming Angle5' Setback

50' Target Distance

DBF18 SPG35HPS

2

1

10'20'30'40'

50'

40'

30'

20'

10'

I.E.S. Type: 1H x 3V Field Angle: 16.1° x 31.7° (10% of max.) Beam Angle: 9.3° x 17.9° (50% of max.)

4,000 Initial Lumens Test No.: KL00441

ED-17 50W HPS

0° Optical Aiming Angle5' Setback

50' Target Distance

DBF18 SPG50HPS

21

5

10'20'30'40'

50'

40'

30'

20'

10'

I.E.S. Type: 1H x 3V Field Angle: 16.1° x 31.7° (10% of max.) Beam Angle: 9.3° x 17.9° (50% of max.)

6,300 Initial Lumens Test No.: KL00437

ED-17 70W HPS

0° Optical Aiming Angle5' Setback

50' Target Distance

DBF18 SPG70HPS

5

21

10'20'30'40'

50'

40'

30'

20'

10'

I.E.S. Type: 1H x 3V Field Angle: 16.1° x 31.7° (10% of max.) Beam Angle: 9.3° x 17.9° (50% of max.)

9,500 Initial Lumens Test No.: KL00371

ED-17 100W HPS

0° Optical Aiming Angle5' Setback

50' Target Distance

DBF18 SPG100HPS

105

2

1

10'20'30'40'

50'

40'

30'

20'

10'

I.E.S. Type: 1H x 3V Field Angle: 13.0° x 33.4° (10% of max.) Beam Angle: 6.5° x 19.5° (50% of max.)

16,000 Initial Lumens Test No.: KL00375

ED-17 150W HPS

0° Optical Aiming Angle5' Setback

50' Target Distance

DBF18 SPG150HPS

Page 31: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

DBF19

HG - Horizontal Grazer

KIM LIGHTING 29

50'

40'

10'20'30'40'

30'

20'

10'.5

.2.1.05

I.E.S. Type: 6H x 4V Field Angle: 105.4° x 51.5° (10% of max.) Beam Angle: 62.6° x 12.8° (50% of max.)

3,400 Initial Lumens Test No.: KL00390

T-6 Clear G-12 Base39W Metal Halide

0° Optical Aiming Angle5' Setback

30' Target Distance

DBF19 HG39PMH

50'

40'

10'20'30'40'

30'

20'

10'

.5.2.1

.05

I.E.S. Type: 6H x 4V Field Angle: 116.7° x 53.9° (10% of max.) Beam Angle: 74.0° x 20.9° (50% of max.)

4,000 Initial Lumens Test No.: KL00467

ED-17 50W Metal Halide

0° Optical Aiming Angle5' Setback

30' Target Distance

DBF19 HG50PMH

50'

40'

10'20'30'40'

30'

1.5.2.1.05

20'

10'

50'

40'

10'20'30'40'

30'

20'

10'

I.E.S. Type: 6H x 4V Field Angle: 116.7° x 53.8° (10% of max.) Beam Angle: 74.0° x 20.9° (50% of max.)

5,900 Initial Lumens Test No.: KL00462

ED-17 70W Metal Halide

0° Optical Aiming Angle5' Setback

30' Target Distance

DBF19 HG70PMH

50'

40'

10'20'30'40'

30'

20'

10'

2

1.5.2

.05

I.E.S. Type: 6H x 4V Field Angle: 116.7° x 53.8° (10% of max.) Beam Angle: 74.0° x 20.9° (50% of max.)

8,800 Initial Lumens Test No.: KL00389

ED-17 100W Metal Halide

0° Optical Aiming Angle5' Setback

30' Target Distance

DBF19 HG100PMH

.1

50'

40'

10'20'30'40'

30'

20'

10'

21

.5.2

.1.05

I.E.S. Type: 6H x 4V Field Angle: 120.6° x 60.8° (10% of max.) Beam Angle: 81.6° x 31.7° (50% of max.)

12,600 Initial Lumens Test No.: KL00455

ED-17 150W Metal Halide

0° Optical Aiming Angle5' Setback

30' Target Distance

DBF19 HG150PMH

50'

40'

10'20'30'40'

30'

20'

10'

21

.5.2

.1.05

I.E.S. Type: 6H x 4V Field Angle: 120.6° x 60.8° (10% of max.) Beam Angle: 81.6° x 31.7° (50% of max.)

12,800 Initial Lumens Test No.: KL00394

ED-17 175W Metal Halide

0° Optical Aiming Angle5' Setback

30' Target Distance

DBF19 HG175MH

50'

40'

10'20'30'40'

30'

20'

10'

.5

.2.1.05

I.E.S. Type: 6H x 4V Field Angle: 113.0° x 55.0° (10% of max.) Beam Angle: 69.7° x 27.0° (50% of max.)

2,250 Initial Lumens Test No.: KL00494

ED-17 35W HPS

0° Optical Aiming Angle5' Setback

30' Target Distance

DBF19 HG35HPS

50'

40'

10'20'30'40'

30'

20'

10'.5

.2.1

.05

I.E.S. Type: 6H x 4V Field Angle: 112.9° x 55.0° (10% of max.) Beam Angle: 69.7° x 26.9° (50% of max.)

4,000 Initial Lumens Test No.: KL00484

ED-17 50W HPS

0° Optical Aiming Angle5' Setback

30' Target Distance

DBF19 HG50HPS

50'

40'

10'20'30'40'

30'

20'

10'

1

.5.2.1.05

I.E.S. Type: 6H x 4V Field Angle: 112.9° x 55.0° (10% of max.) Beam Angle: 69.7° x 27.0° (50% of max.)

6,300 Initial Lumens Test No.: KL00478

ED-17 70W HPS

0° Optical Aiming Angle5' Setback

30' Target Distance

DBF19 HG70HPS

50'

40'

10'20'30'40'

30'

20'

10'

2

1.5.2.1.05

I.E.S. Type: 6H x 4V Field Angle: 112.9° x 55.0° (10% of max.) Beam Angle: 69.7° x 27.0° (50% of max.)

9,500 Initial Lumens Test No.: KL00399

ED-17 100W HPS

0° Optical Aiming Angle5' Setback

30' Target Distance

DBF19 HG100HPS

50'

40'

10'20'30'40'

30'

20'

10'21

.5.2.1.05

I.E.S. Type: 6H x 4V Field Angle: 105.3° x 48.4° (10% of max.) Beam Angle: 70.6° x 22.8° (50% of max.)

16,000 Initial Lumens Test No.: KL00378

ED-17 150W HPS

0° Optical Aiming Angle5' Setback

30' Target Distance

DBF19 HG150HPS

Page 32: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

Lamp and Electrical Guide

30 KIM LIGHTING

Lamp

35HPS ED-17 Clear 120 0.38 0.65 0.78 0.78Medium Base 35 S-76 24000+ 2250 277 0.38 0.65 0.38 0.65

50HPS 120 0.55 1.24 0.58 1.24ED-17 Clear 50 S-68 24000+ 4000 208 0.33 0.60 0.35 0.60Medium Base 240 0.30 0.52 0.31 0.52

277 0.26 0.45 0.25 0.4570HPS 120 0.81 1.45 0.75 1.45

E-17 Clear 70 S-62 24000+ 6300 208 0.47 0.85 0.45 0.85Medium Base 240 0.40 0.75 0.37 0.75

277 0.35 0.65 0.35 0.65347 0.30 0.55 0.30 0.55480 0.21 0.36 0.21 0.36

100HPS 120 1.15 2.20 1.30 2.20E-17 Clear 100 S-54 24000+ 9500 208 0.67 1.25 0.75 1.25Medium Base 240 0.58 1.10 0.65 1.10

277 0.50 0.85 0.60 0.85347 0.39 0.70 0.45 0.70480 0.22 0.34 0.21 0.34

150HPS 120 1.65 2.80 2.00 2.80E-18 Clear 150 S-55 24000+ 16000 208 0.95 1.60 1.15 1.60Medium Base 240 0.83 1.40 1.00 1.40

277 0.72 1.25 0.85 1.25347 0.56 0.92 0.52 0.92480 0.42 0.70 0.50 0.70

39MH 120 0.52 0.82 0.53 0.82T-6 Clear 39 M-130 12000+ 3400 208 0.30 0.48 0.31 0.48G-12 Base 240 0.27 0.42 0.28 0.42

277 0.22 0.36 0.23 0.36347 0.20 0.30 0.21 0.30

50MH 120 0.63 1.16 0.87 1.16ED-17 Clear 50 M-110 15000+ 4250 208 0.40 0.67 0.51 0.67Medium Base 10000+ 4000 240 0.35 0.57 0.47 0.57

277 0.33 0.50 0.32 0.50347 0.24 0.48 0.21 0.48

70MH 120 0.85 1.70 0.80 1.70ED-17 Clear 70 M-98 15000+/ 6200/ 208 0.52 1.04 0.50 1.04Medium Base 10000+ 5900 240 0.44 0.87 0.43 0.87

277 0.39 0.78 0.39 0.78T-6 Clear 12000 6600 347 0.28 0.65 0.20 0.65G-12 Base 480 0.23 0.50 0.26 0.50

100MH 120 1.15 2.30 1.20 2.30ED-17 Clear 100 M-90 15000+/ 9300/ 208 0.66 1.40 0.80 1.40Medium Base 11000+ 8800 240 0.58 1.15 0.65 1.15

277 0.50 1.00 0.60 1.00347 0.40 1.00 0.40 1.00480 0.30 0.55 0.30 0.55

150MH 120 1.60 3.65 1.75 3.65ED-17 Clear 150 M-102 15000+/ 14000/ 208 1.00 2.10 1.30 2.10Medium Base 11000+ 12800 240 0.80 1.80 0.85 1.80

277 0.70 1.58 0.77 1.58T-6 Clear 12000 14000 347 0.55 1.25 0.65 1.25G-12 Base 480 0.42 0.81 0.45 0.81

Lam

pW

atts

AN

SI

Bal

last

Typ

e

Lif

e(H

ou

rs)

V/H

Init

ial

Lu

men

s1

V/H

Volt

age

Ope

ratin

gA

mps

.

Op

enC

ircu

it

Sta

rtin

gA

mp

s.

Max

.A

mp

s.

HIGH PRESSURE SODIUM

METAL HALIDE

Page 33: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

KIM LIGHTING 31

Lamp

175MH 120 1.80 1.80 1.30 1.80ED-17 Clear 175 M-57 10000+/ 14000 208 1.04 1.04 0.75 1.04Medium Base 7000+ 240 0.90 0.90 0.65 0.90

277 0.80 0.80 0.55 0.80347 0.65 0.70 0.50 0.70480 0.45 0.45 0.35 0.45

42PL 120 0.39 — 0.39 0.39Coated 42 — 10000+ 3200 208 0.23 — 0.23 0.23GX24q4 4-pin Base 240 0.20 — 0.20 0.20

277 0.17 — 0.17 0.17

METAL HALIDE (continued)

Lam

pW

atts

AN

SI

Bal

last

Typ

e

Lif

e(H

ou

rs)

V/H

Init

ial

Lu

men

s1

V/H

Volt

age

Ope

ratin

gA

mps

.

Op

enC

ircu

it

Sta

rtin

gA

mp

s.

Max

.A

mp

s.

COMPACT FLUORESCENT

1 All Initial Lumen values shown are approximate and may vary from one manufacturer to another as well as one operating position to another. Consult lampmanufacturer’s data for exact lumen and life data.

NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative.Lamps by others.

CAUTION: Fixtures must be grounded in accordance with national, state, and/or local electrical codes. Failure to do so may result in serious personal injury.

Page 34: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

32 KIM LIGHTING

Page 35: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

KIM LIGHTING 33

Surface Reflectance

Brick, dark buff 40%

Brick, light buff 48%

Brick, dark red 30%

Concrete 40%

Glass, clear 7%

Glass, reflective 20-30%

Glass, tinted 7%

Vegetation, average 25%

White Marble 45%

White Paint, new 75%

White Paint, old 55%

Material Reflectance

Approximate Reflectance of Some Common Surfaces

Application Engineering Services

Applications AssistanceKim Lighting utilizes the latest computer technology and softwareto provide specifiers with reliable evaluations of lighting systemperformance. We can analyze a proposed luminaire layout orprovide recommendations based on performance criteria.Electronic copies of plans can be sent directly [email protected]. Hard copies can be sent by fax at864-678-1743, or they can be mailed to Applications Dept, 701 Millennium Blvd, Greenville, SC 29607.

Photometric FilesKim Lighting .ies format photometric files are available for use inlighting calculation software. The complete IES File Library is onthe internet at www.kimlighting.com.

Page 36: ARCHITECTURAL FLOOD DBF Direct Burial Floodlight · Two Basic Configurations 1 ... DBF Direct Burial Floodlight The Direct Burial Floodlight ... with true visual aiming ability, the

How may we serve you better? Let us know by visiting our web site at:

www.kimlighting.com

Your input is valuable to us.

Because of a continuing product improvementprogram, Kim Lighting reserves the right tochange specifications without notice.

Hubbell Lighting, Inc.

D i r e c t B u r i a lF l o o d l i g h t35 - 175 Wat t H . I .D. / 42 - 120 Wat t PL