Floodlighting 1 Floodlighting and Road Lighting Powerful and long-lasting lights for maximum illumination and road safety

22 March Floodlight

Embed Size (px)

Citation preview

Page 1: 22 March Floodlight

Floodlighting 1

Floodlighting and Road LightingPowerful and long-lasting lights for maximum illumination and road safety

Page 2: 22 March Floodlight

2 Floodlighting Floodlighting 3

conTempoPhilips conTempo floodlight has a registered design that blends well with contemporary outdoor environments. It has a rugged pressure die-casted aluminum housing with corrosion resistant powder coating. Philips conTempo also features an integrated energy saving copper and aluminium ballast, electronic semi-parallel ignitor and capacitor. The unit has passed rigoroustests for dust and water ingress protection.

Floodlighting

Lighting should perfectly illuminate the sports players, it should never disturb them or be uncomfortable for the live spectators. Many years of experience have enabled Philips engineers to perfect an unequalled competence for application development and optimal sports lighting design, from top-end through recreational sports facilities.

Whether it’s a production centre, container terminal, or industrial site there are continuous activities throughout the night. The efficiency of these locations is greatly extended by lighting which contributes to safety and security of people working on the site. The efficiency of the system due to long burning hours and the limitation of spill light is key for surrounding environment, which might be residential is is key for area lighting.

Today, halogen-based and HID-based flood lights are available in various wattages for sports and area applications.

Features & benefits• Blends well with contemporary

outdoor environments – Rugged pressure die-casted aluminium housing

– Corrosion resistant powder coating – Rigourously tested for dust and water

ingress protection• Reduce your electricity cost – Integrated energy saving copper and

aluminium ballast – Custom-designed peened anodized

reflector for efficient symmetrc and asymmetric optics

• Friendly user interface eases installation and maintenance – Hinged toughened glass cover for

easy operation – Ergonomic installation and

maintenance mechanisms

Application• General lighting, wall washing,

sports court, park, billboard, sculpture and ports

Flood-lighting

RoadLighting

HaloliteconTempo

Smartway

page3

page13

page10

Road Lighting

With over one hundred years of experience, Philips Lighting understands the issues associated with road lighting and offers the experience and solutions to create a safe comfortable environment for all road users, whether they are drivers, cyclists or pedestrians.

All luminaries are optimized in wattage, in order to precisely the right level of light, in the right place at the right time; lamps and electrical components used offer the longest possible lifetime. Compact, aesthetically pleasing luminaries are being designed, often with aluminum housings, reflecting the increasing importance being attached to the daytime appearance of light points, Optics are being adapted to the new lamps, improving performance and the growing popularity of high quality white light sources.

Better materials and IP66 are contributing to the durability of installations. The increasing use of longer-lasting lamps, electronic gear and telemanagement is optimizing running costs.

Floodlighting

Page 3: 22 March Floodlight

4 Floodlighting Floodlighting 5

conTempoType RVP150

RVP250

RVP350

Light source HID:

1 x CDM-TD / Rx7s / 70, 150 W

1 x CDM-TT / E27 / 70 W

1 x CDM-TT / E40 / 150 W

1 x SON-T / E27 / 70 W

1 x SON-T / E40 / 150, 250, 400 W

1 x SON-T Plus / E27 / 70 W

1 x SON-T Plus / E40 / 150, 250, 400 W

1 x HPI-T / E40 / 250, 400 W

1 x HPI-T Plus / E40 / 250, 400 W

1 x MHN-TD / Rx7s / 70, 150 W

Lamp included No

Yes (K)

Gear Electro magnetic (low loss), 220-240 V / 50-60 Hz: Inductive, parallel compensated (IC)

Optic Symmetric reflector (S)

Asymmetric reflector (AS)

Ignitor Semi-parallel (SP)

Materials and finish Die-casted aluminum housing with corrosion resistant powder coating

Peened anodized reflector

Premium bonded silicon gasket

Quick-release steel toggles

Copper and aluminium ballast, electronic ignitor and PF improvement capacitor

Nylon grommet ,ceramic lamp holder, silicon cable with fiber-glass sleeving

Shatter-resistant front safety glass

Installation Mild steel mounting bracket

One installation option available: standing

Please turn off the power supply when product is not in use for a long time

Accessories Front glass is available as a spare part

Classifications IP65

Class I

Complies with IEC 60598

Preferred selection

Product ID Weight (kg) Order code

conTempo L

RVP350 SON-T250W IC 220V-50Hz S SP CN 10.40 910401648780

RVP350 SON-T400W IC 220V-50Hz S SP CN 12.10 910401648880

RVP350 HPI-T250W IC 220V-50Hz S SP CN 9.55 910401648980

RVP350 HPI-T400W IC 220V-50Hz S SP CN 10.20 910401649080

RVP350 SON-T250W IC 220V-50Hz A SP CN 10.40 910401649180

RVP350 SON-T400W IC 220V-50Hz A SP CN 12.10 910401649280

RVP350 HPI-T250W IC 220V-50Hz A SP CN 9.55 910401649380

RVP350 HPI-T400W IC 220V-50Hz A SP CN 10.20 10401649480

conTempo M

RVP250 MHN-TD70W IC 220V-50Hz S SP CN 6.20 910401648180

RVP250 MHN-TD150W IC 220V-50Hz S SP CN 7.05 910401648280

RVP250 SON-T70W IC 220V-50Hz S SP CN 6.20 910401649580

RVP250 SON-T150W IC 220V-50Hz S SP CN 7.05 910401648380

RVP250 MHN-TD70W IC 220V-50Hz A SP CN 6.20 910401648480

RVP250 MHN-TD150W IC 220V-50Hz A SP CN 7.05 910401648580

RVP250 SON-T70W IC 220V-50Hz A SP CN 6.20 910401649680

RVP250 SON-T150W IC 220V-50Hz A SP CN 7.05 910401648680

conTempo S

RVP150 SON-T70W K IC 220V-50Hz SP S 4.54 911401069480

RVP150 SON-T70W K IC 220V-50Hz SP A 4.54 911401069580

RVP150 CDM-TT70W K IC 220V-50Hz SP S 4.54 911401069080

RVP150 CDM-TT70W K IC 220V-50Hz SP A 4.54 911401069180

RVP150 MHN-TD70W K IC 220V-50Hz SP S 4.54 911401069680

RVP150 MHN-TD70W K IC 220V-50Hz SP A 4.54 911401069780

RVP150 CDM-TD70W K IC 220V-50Hz SP S 4.54 911401069280

RVP150 CDM-TD70W K IC 220V-50Hz SP A 4.54 911401069380

RVP150 SON-T70W IC 220V-50Hz SP S 4.54 911401068680

RVP150 SON-T70W IC 220V-50Hz SP A 4.54 911401068780

RVP150 CDM-TT70W IC 220V-50Hz SP S 4.54 911401068280

RVP150 CDM-TT70W IC 220V-50Hz SP A 4.54 911401068380

RVP150 MHN-TD70W IC 220V-50Hz SP S 4.54 911401068880

RVP150 MHN-TD70W IC 220V-50Hz SP A 4.54 911401068980

RVP150 CDM-TD70W IC 220V-50Hz SP S 4.54 911401068480

RVP150 CDM-TD70W IC 220V-50Hz SP A 4.54 911401068580

conTempo

77

9

141

14

RVP150 bracket

RVP350 bracket

77170

9

RVP250 bracket

85

10.4

327

C

D

BF

E A B C D E F

(mm) (mm) (mm) (mm) (mm) (mm)

RVP150 267 303 284 306 109 347

RVP250 327 346 343 363 117 424

RVP350 425 430 440 460 137 476

Product dimensions

All dimensions in mm

Page 4: 22 March Floodlight

6 Floodlighting Floodlighting 7

The lighting requirements of billboards

CR I: >65 Color temperature of lamp source (CCT): >3000K

Recommended Illumination (lux):Tinted billboard surface & dark environments > 200 lux Dark billboard surface & dark environments > 500 lux Tinted billboard surface & bright environments > 500 lux Dark billboard surface & bright environments > 1000 lux

Uniformity (UI) :minimum (billboard surface) lux =>0.4 average (billboard surface) lux

For luminaires installed below the billboard For luminaires installed above & below the billboard

1/2 S

SW

S

H

0.75M

1/2 SD 1/2 S

1/2 S

SW

S

H

0.75M

D

Application example: at 200 lux

1. Determine the size of the billboard, as depicted above: Height = H Width = W

2. Determine the data from the matrices in the following steps: - Refer to the cell in the 200 lux matrix, corresponding to the

matching height (H) & width (W) - Identify the type of luminaire from the first letter: A, B or C - Obtain the required quantity of luminaires to achieve 200 lux

(number suffix after A,B or C) - Obtain the distance of the luminaires from the billboard

(under column ‘D’)

For example, if your search results in B7 from the matrix, this means you require: 7 sets of B type of luminaires, at a distance of 2.6 meters from the billboard

3. Ideally: a. The distance between individual luminaires should be less than 3.5m b. The distance between the vertical edge of the billboard &

first or last luminaire should be less than half the distance between two individual luminaires, as depicted above.

Note• A maintenance index of 0.8 had been included in the given data • I M (in column D) refers to the distance – i.e. the mounted

luminaire is 1 meter away from the lower edge of the billboard

Billboard lighting application guide

5M 6M 7M 8M 9M 10M 11M 12M 13M 14M 15M 16M D Suggested Mounting

200L

ux

4M A2 A2 A3 A3 A3 A4 A4 A4 A4 A4 A5 A51.2M

Mounted below the billboard

5M A2 A3 A3 A3 A4 A4 A4 A5 A5 A5 A6 A6

6M A3 A3 A4 A4 A4 A5 A5 A6 A6 A6 B5 B5 1.5M

7M A3 B3 B3 B3 B3 B4 B4 B4 B4 B5 B5 B5 1.8M

8M B3 B3 B3 B4 B4 B4 B5 B5 B5 B5 B6 B6 2.5M

9M B3 B4 B4 B4 B4 B5 B5 B5 B6 B6 B6 B7 2.6M

10M B4 B4 B5 B5 B5 B5 B6 C4 B6 C5 C5 C5 2.8M

500L

ux

4M C2 C2 C3 C3 C3 C4 C4 C4 C4 C4 C5 C5 1.2M

Mounted below the billboard

5M C3 C3 C3 C3 C4 C4 C4 C5 C5 C5 C6 C6 1.5M

6M C3 C3 C4 C4 C4 C5 C5 C6 C6 C6 C7 C10 1.8M

7M C4 C4 C4 C5 C5 C6 C6 C6 C7 C7 C8 C8 2.5M

8M C4 C5 C5 C6 C6 C7 C7 C7 C8 C8 C9 C9 2.6M

9M C5 C5 C6 C6 C7 C7 C8 C8 C9 C9 C10 C102.8M

10M C6 C6 C7 C8 C8 C8 C9 C9 C10 C10 C12 C11

1000

Lux

4M C3 C3 C4 C5 C5 C6 C6 C7 C7 C8 C8 C9 1.2M

Mounted below the billboard

5M C4 C4 C5 C6 C6 C7 C7 C8 C8 C9 C9 C10 1.5M

6M C5 C6 C6 C8 C8 C9 C10 C11 C11 C12 C13 C13 1.8M

7M C4 C4 C4 C6 C6 C6 C6 C6 C8 C8 C8 C8 2.0M

Mounted below & above the

billboard separately

8M C4 C6 C6 C6 C6 C8 C8 C8 C8 C10 C10 C10 2.5M

9M C4 C6 C6 C6 C8 C8 C8 C10 C10 C10 C10 C122.8M

10M C6 C6 C8 C8 C8 C10 C10 C10 C12 C12 C12 C14

1500

Lux

4M C5 C5 C6 C7 C7 C8 C9 C10 C10 C11 C12 C13 1.2M

Mounted below the billboard

5M C6 C6 C7 C8 C9 C10 C11 C11 C12 C13 C14 C15 1.5M

6M C7 C8 C9 C10 C11 C12 C13 C14 C15 C16 C17 C18 1.8M

7M C6 C6 C6 C8 C8 C10 C10 C10 C10 C12 C12 C14 2.0M

Mounted below & above the

billboard separately

8M C6 C8 C8 C8 C10 C10 C12 C12 C14 C14 C14 C16 2.5M

9M C8 C8 C10 C10 C12 C12 C12 C14 C14 C14 C16 C162.8M

10M C8 C10 C10 C12 C12 C14 C14 C16 C16 C18 C18 C20

Type Product descriptionA conTempo RVP250 1XMHN-TD 150W

B conTempo RVP350 1XHP1-T 250W

C conTempo RVP350 1XHP1-T 400W

W

H

Selection matrix for billboard lighting

Page 5: 22 March Floodlight

8 Floodlighting Floodlighting 9

Lamp type SON-T HPI-T/MHN-TD-Warm white light -Limited colour rendering

-Cool white light -Good colour rendering

Purpose Orientation lighting Visual Task lighting

Light level (lux) 10-30 30-50

Side of area = Spacing (m)

Mast height (m)

Light level(lux) *

Luminaire (Symmetrical) & lamp type

SON-T HPI-T/MHN-TD

S=11 H=6 10-30 conTempo M SON-T 70W conTempo M MHN-TD 150W

30-40 conTempo M SON-T 150W conTempo L HPI-T 250W

S=16 8<=H<=10 10-20 conTempo M SON-T 150W conTempo L HPI-T 250W

30-40 conTempo L SON-T 250W conTempo L HPI-T 400W

S=20 H=12 10-30 conTempo L SON-T 250W conTempo L HPI-T 400W

30-50 conTempo L SON-T 400W 2*conTempo L HPI-T 400W

S=24 H=15 10-20 conTempo L SON-T 250W conTempo L HPI-T 400W

30-50 2*conTempo L SON-T 400W 2*conTempo L HPI-T 400W

*Lighting levels are maintained values, based on a maintenance factor of 0.8

S

H

S

S

S/2

S/2

Area lighting application guide

Color of facade material Brownish/Yellowish OtherLamp type SON-T

Warm white lightLimited colour rendering

HPI-T/MHN-TD Cool white light Good colour rendering

Conditions Light surface dark surroundings

Light surface brightsurroundings or dark surface dark surroundings

Dark surface bright surroundings

Light level (lux) 50-75 100 200

Façade height (mtrs) Light level (lux) * Luminaire (Symmetrical) & lamp type

SON-T HPI-T/MHN-TD

H=6 75 conTempo M SON-T 70W conTempo M MHN-TD 150W

100 conTempo M SON-T 150W conTempo L HPI-T 250W

200 conTempo L SON-T 250W conTempo L HPI-T 400W

H=10 50 conTempo M SON-T 150W conTempo L HPI-T 250W

100 conTempo L SON-T 250W conTempo L HPI-T 400W

200 conTempo L SON-T 400W 2*conTempo L HPI-T 400W

*Lighting levels are maintained values, based on a maintenance factor of 0.8

4m2m

6m 4m2m

8m

H=6m

35m

S=12mS=12m

11m17m

Principal Playing Area (PPA)

Total Playing Area (TPA)

Light level (lux)* Luminiare & number of luminiares per mast

Standard PPA 165 conTempo L SON-T 400W Asymmetrical -1 piece per mast

TPA 145

Deluxe PPA 330 conTempo L SON-T 400W Asymmetrical -2 pieces per mast

TPA 290

* as per international tennis federation recommendations; based on standard grid of 2x2 mtrs for PPA, and 4x4 mtrs for TPA. All lighting levels are maintained values, based on a maintenance factor of 0.8

Facade lighting application guide

Sports lighting application guide

Façade Height 6m Façade Height 10m

Page 6: 22 March Floodlight

10 Floodlighting Floodlighting 11

HalolitePhilips Halolite is a floodlight with a compact and sturdy design. It is lightweight with a die-casted aluminium housing and corrosion-proof powder coating. Its high grade anodised reflectors provide an efficient beam for either downward or upward applications. Easy lamp replacement and rear access for mains connection. Merchandise packaging is available.

Features & benefits• Easy application to meet

your requirements – Wide light beam

– Compact and sturdy design – Corrosion-proof, die-casted

aluminium housing with powder coating

– Toughened glass cover IP54 – Waterproof and heat resistant

silicone gaskets – High-grade anodized reflector – Provide an efficient beam for either

downward or upward applications• Easy maintenance, easy to use – Quick rear access for

main connections – Lamp replacement through

front window

Application• General lighting: garden, billboard,

sculture and security

Type QVF133

QVF135

QVF137

QVF139

Light source Halogen:

1 x Halogen / R7s / 150, 500, 1000, 1500 W

Lamp included No

Yes (K)

Materials and finish Die-casted aluminium housing with powder coating

Anodized reflectors

Silicone gaskets

Installation Mild steel mounting bracket

One option available: standing

Please turn off the power supply when product is not in use for a long time

Accessories Front glass is available as a spare part

Classifications IP54

Class I

Complies with IEC 60598

Halolite

54

QVF133 QVF135

QVF137 QVF139

All dimensions in mm

Product dimensions

Floodlighting

Page 7: 22 March Floodlight

12 Road Light Road Light 13

SmartwayThis cost effective road lighting delivers a fresh new light to city roads, residential areas and industrial estates while making a significant contribution to a safer and more comfortable environment

Features & benefits• Well designed for good

daytime aesthetics• Long-lasting and robust die

cast housing• Ribbed cover for good impact

resistance• High quality gasket and glue-free lamp

compartment installation for IP65 ingress protection

• Intelligent raised frame design for better ingress protection

• Breathing filter and heat sink for good air circulation and heat dissipation

• ‘Twist and Release’ lamp replacement and easy gear replacement for safety and time efficient maintenance

• High purity aluminum reflector for good lighting performance

• Double fold strong open arm for durable and repeated use

Application• City streets, residential roads,

industrial areas

SmartwayType SPP180

SPP185

SPP186

Power supply 220/230/240V 50Hz for SON-T220/230/240V 50-60Hz for CPO-T

Power factor >0.85

Classification IK05, IP65/IP43

Materials and finish Non corrosive high-pressure die-cast aluminum for canopy and frame

High purity aluminum reflector

Toughened glass bowl

Stainless steel clip, Silicon rubber gasket

Color: RAL7040

Installation Side-entry with pole diameter of 48-60 mm for SON-T150W/250W and CPO-T60/140W lamp versions

Side-entry with pole diameter of 34-50 mm for SON-T 70W lamp versions (50S)

Accessories Front glass is available as a spare part

Lamp options SON-T70/150/250 W, CPO-T60/140W

Preferred selection

Product ID Weight (kg) Order code

conTempo L

SPP180 SON-T150W 220V-50Hz GB GR 6.0 910403630194

SPP180 SON-T150W 230V-50Hz GB GR 6.0 910403630195

SPP180 SON-T150W 240V-50Hz GB GR 6.0 910403630196

SPP180 MAX150W GB GR 4.3 910403630197

SPP185 MAX70W-E27 E GB GR 34/50S 2.4 911400989780

SPP185 SON-T70W 220V-50Hz GB GR 34/50S 3.7 911400989480

SPP185 SON-T70W 230V-50Hz GB GR 34/50S 3.7 911400989580

SPP185 SON-T70W 240V-50Hz GB GR 34/50S 3.7 911400989680

SPP186 CPO-T140W K 220-240V GB GR 6.0 910403630187

SPP186 CPO-TW60W 220-240V K GB GR 6.0 910403630188

SPP186 SON-T250W 220V GB SD GR 7.4 910403630191

SPP186 SON-T250W 230V GB SD GR 7.4 910403630192

SPP186 MAX250W-E40 E GB GR 48/60S 4.3 911400990480

SPP186 SON-T150W 220V-50Hz GB GR 48/60S 6.8 911400989880

SPP186 SON-T150W 230V-50Hz GB GR 48/60S 6.8 911400989980

SPP186 SON-T150W 240V-50Hz GB GR 48/60S 6.8 911400990080

SPP186 SON-T250W 220V-50Hz GB GR 48/60S 7.4 911400990180

SPP186 SON-T250W 230V-50Hz GB GR 48/60S 7.4 911400990280

SPP186 SON-T250W 240V-50Hz GB GR 48/60S 7.4 911400990380

Please contact your local Philips representative for additional configurations

Page 8: 22 March Floodlight

14 Floodlighting

©2012 Koninklijke Philips Electronics N.V.

All rights reserved. Reproduction in whole or in part is prohibited without

prior written consent of the copyright owner. The information presented

in this document does not form part of any quotation or contract, is

believed to be accurate and reliable and may be changed without notice.

No liability will be accepted by the publisher for any consequence of its

use. Publication thereof does not convey nor imply any license under

patent- or other industrial or intellectual property rights.

February 2012