Upload
others
View
12
Download
0
Embed Size (px)
Citation preview
Triple IR (IR3) Flame Detector ─> Model 40/40I 6207 s Industry, Inc. Building Technologies Division
s Catalog Sheet
Fire Safety & Security Products
Specialized Detection Devices Triple IR (IR3) Flame Detector Model 40/40I
ARCHITECT AND ENGINEER SPECIFICATIONS• Explosion proof
• Triple-spectrum design
• Sensitivity selection
• RS-485 Interface
• Heated window
• User-programmable configuration
• Resistant to false alarms
• Automatic and manual built-in-test (BIT)
• MTBF minimum of 150,000 hours
• 0-20mA source configuration Stepped
Product Overview RatingsThe Triple IR (IR3) Flame Detector is a reliable, compact and self-contained triple-spectrum infrared flame detector that detects fuel and gas fires at long distances with the highest immunity to false alarms. Model 40/40I (IR3) can detect a 1ft2 (0.1m2) gasoline pan fire at 215 ft (65m) in less than 5 seconds.
Model (40/40I) has considerable durability and weather-related resistance, and is comprised of the following characteristics:
Heated window, eliminating condensation and icing
Highway Addressable Remote Transducer (HART) capabilities, for digital communications low-power requirements
A compact, lighter design
Due to increased reliability, Model 40/40I is SIL2 (TUV) Approved to IEC 61508.
General: Adjustable Time Delay: Up to 30 seconds
Spectral Response: Three (3) IR Bands
Response Time: Typical: 5 seconds
Sensitivity Range: Four (4) sensitivity ranges for 1 ft2 (0.1m2) n-Heptane pan fire from 50 ft (15m) to 215 ft (65m)
Built-in-Test: Manual and Automatic BIT
Field of View: 100° horizontal, 95° vertical
Heated Optics: To eliminate condensation and icing on the window
Operating: -67°F (-55°C) to 167°F (75°C)
Optional: -67°F (-55°C) to 185°F (85°C)
Environmental Ranges:
{up to 95% RH} Storage: -67°F (-55°C) to 185°F (85°C) Diesel-fuel fire at 150 ft (45m) 95% Ethanol fire at 135 ft (40m) Gasoline fire at 215 ft (65m) IPA (Isopropyl Alcohol) fire at 135 ft (40m) JP5 fire at 150 ft (45m) Kerosene fire at 150 ft (45m) LPG* fire at 100 ft (30m) Methane* fire at 100 ft (30m) Methanol fire at 115 ft (35m) n-Heptane fire at 215 ft (65m) Office paper fire at 33 ft (10m)
Detection Ranges:
{at highest sensitivity setting for 1ft2 [0.1m2]
pan fire}
Polypropylene Pellets fire at 16 ft (5m)
* denotes 20’’ (O.5m) high, 8’’ (0.2m) wide plume fire
• ATEX; CSA; CSFM; DNV; EN54-10 (LPCB); FM; FMC; IECEx; GOST R, and SIL2 (TUV) Approved
(713)-395-1508Fax: (713) [email protected]
IndustrialZoneP.O. Box 667306Houston, Texas 77266United States
s Industry, Inc. Building Technologies Division
Ratings ─ (continued) Electrical:
Power Supply: Operating Voltage: 18-32 VDC
Standby: 90mA, max. {110mA with heated window} Power
Consumptions: Alarm: 130mA, max. {160mA with heated window}
Connection: 2-x-3/4’’ - 14NPT conduits, or 2’’-x-M25-x-0.15cm ISO
Interface: Includes 12 terminals with five (5) factory-set wiring options
Wiring: 12 - 22AWG (0.25cm2 - 0.03cm2)
Input Protection: According to MIL-STD-1275B
Electromagnetic Compatibility:
EMI / RFI protected (to EN61326-3 and EN61000-6-3)
Outputs: Alarm: 5A at 30 VDC or 250 VAC
Fault and Accessory: 5A at 30 VDC or 250 VAC Relays: Fault relay normally closed (NC), others normally open (NO)
Fault: 0 + 1mA BIT Fault: 2mA ± 10 % Normal: 4mA ± 10 % Warning: 16mA ± 5 % Alarm: 20mA ± 5 %
0-20mA stepped: Sink (source-option)
configuration
Resistance Loop: 100-600
HART Protocol
Optional HART communications on the 0-20mA analog current (FSK) -- used for maintenance, configuration changes and asset management. Available in mA source-output wiring options.
RS-485
The detector is equipped with a RS-485 proprietary communication-protocol link that can be used in installations with computerized controllers. The RS-485 link is Modbus® compatible.
Mechanical: Dimensions: 4" x 4.6" x 6.2" (10.2 x 11.8 x 15.8 cm)
Aluminum: 2.8 Lbs (1.3 Kgs) St.St 316L: 6.1 Lbs (2.8 Kgs) Weight: Tilt Mount: 2.2 Lbs (1.0 Kgs)
Enclosure[s]:
Aluminum, heavy-duty and low-copper (less than 1%), red epoxy -enamel finish Optional: Stainless steel 316L with electro-polish finish
Accessories: Model # Part # 40 / 40 Air Shield: 777161 S54430-F307-A1
Fire Simulator: 20/20-311 S54430-F300-A1
Laser Pointer: (Detector-area coverage) 777166 S54430-F309-A1
Mini Laptop Kit: 777820 S54430-F295-A1
USB, RS-485 Harness Kit: 794079-5 S54430-F312-A1
Tilt Mount: 40/40-001 S54430-F304-A1
Weather Protector: 777163 S54430-F308-A1
Applications Aircraft hangars
Automotive industry
Chemical plants
Explosives and munitions
Offshore oil-and-gas installations
Onshore oil-and-gas installations and pipelines
Petrochemical plants
Pharmaceutical industry
Power-generation facilities: Pumps, generator rooms and unmanned stations
Printing industry
Storage-tank farms
Warehouses
Waste-disposal facilities
Details for Ordering Model
Number Part
Number Description
40/40I-111SF S54430-F7-A1 IR3 FLM DET WO1 75C M25 SS FM 40/40I-111SC S54430-F8-A1 IR3 FLM DET WO1 75C M25 SS CTEX
40/40I-111AF S54430-F9-A1 IR3 FLM DET WO1 75C M25 AL FM
40/40I-111AC S54430-F10-A1 IR3 FLM DET WO1 75C M25 AL CTEX
40/40I-112SF S54430-F11-A1 IR3 FLM DET WO1 75C 3/4" SS FM
40/40I-112SC S54430-F12-A1 IR3 FLM DET WO1 75C 3/4" SS CTEX
40/40I-112AF S54430-F13-A1 IR3 FLM DET WO1 75C 3/4" AL FM
40/40I-112AC S54430-F14-A1 IR3 FLM DET WO1 75C 3/4" AL CTEX
40/40I-121SF S54430-F15-A1 IR3 FLM DET WO1 85C M25 SS FM
40/40I-121SC S54430-F16-A1 IR3 FLM DET WO1 85C M25 SS CTEX
40/40I-121AF S54430-F17-A1 IR3 FLM DET WO1 85C M25 AL FM
40/40I-121AC S54430-F18-A1 IR3 FLM DET WO1 85C M25 AL CTEX
40/40I-122SF S54430-F19-A1 IR3 FLM DET WO1 85C 3/4" SS FM
40/40I-122SC S54430-F20-A1 IR3 FLM DET WO1 85C 3/4" SS CTEX
40/40I-122AF S54430-F21-A1 IR3 FLM DET WO1 85C 3/4" AL FM
40/40I-122AC S54430-F22-A1 IR3 FLM DET WO1 85C 3/4" AL CTEX
40/40I-211SF S54430-F23-A1 IR3 FLM DET WO2 75C M25 SS FM
40/40I-211SC S54430-F24-A1 IR3 FLM DET WO2 75C M25 SS CTEX
40/40I-211AF S54430-F25-A1 IR3 FLM DET WO2 75C M25 AL FM
40/40I-211AC S54430-F26-A1 IR3 FLM DET WO2 75C M25 AL CTEX
40/40I-212SF S54430-F27-A1 IR3 FLM DET WO2 75C 3/4" SS FM
40/40I-212SC S54430-F28-A1 IR3 FLM DET WO2 75C 3/4" SS CTEX
40/40I-212AF S54430-F29-A1 IR3 FLM DET WO2 75C 3/4" AL FM
40/40I-212AC S54430-F30-A1 IR3 FLM DET WO2 75C 3/4" AL CTEX
40/40I-221SF S54430-F31-A1 IR3 FLM DET WO2 85C M25 SS FM
40/40I-221SC S54430-F32-A1 IR3 FLM DET WO2 85C M25 SS CTEX
40/40I-221AF S54430-F33-A1 IR3 FLM DET WO2 85C M25 AL FM
40/40I-221AC S54430-F34-A1 IR3 FLM DET WO2 85C M25 AL CTEX
40/40I-222SF S54430-F35-A1 IR3 FLM DET WO2 85C 3/4" SS FM
40/40I-222SC S54430-F36-A1 IR3 FLM DET WO2 85C 3/4" SS CTEX
40/40I-222AF S54430-F37-A1 IR3 FLM DET WO2 85C 3/4" AL FM
40/40I-222AC S54430-F38-A1 IR3 FLM DET WO2 85C 3/4" AL CTEX
s Industry, Inc. Building Technologies Division
Wiring Configurations ─ Typical ─
Terminal Blocks
5 8 9
Fault Relay 0 ─ 20 mA 0 ─ 20 mA
(N.C.) (N.C.) (Sink)
Fault Relay Alarm Relay 0 ─ 20 mA
(N.C.) (N.C.) Source
s Industry, Inc. Building Technologies Division
Fire Safety 8 Fernwood Road Florham Park, NJ 07932 Tel: (973) 593-2600 FAX: (908) 547-6877 URL: www.SBT.Siemens.com/FIS
(SII‐FS) Printed in U.S.A.
Fire Safety 2 Kenview Boulevard Brampton, Ontario L6T 5E4 / Canada Tel: (905) 799-9937 FAX: (905) 799-9858
April 2011 Supersedes sheet dated 3/2011
(Rev. 1)
Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product’s installation instructions.
(713)-395-1508Fax: (713) [email protected]
IndustrialZoneP.O. Box 667306Houston, Texas 77266United States