Application Note 24 A Simplified Test Set for Op Amp Characterization
Literature Number: SNOA637
A Simplified Test Set forOp Amp Characterization
INTRODUCTION
The test set described in this paper allows complete quanti-tative characterization of all dc operational amplifier param-eters quickly and with a minimum of additional equipment.The method used is accurate and is equally suitable for labo-ratory or production test — for quantitative readout or for limittesting. As embodied here, the test set is conditioned fortesting the LM709 and LM101 amplifiers; however, simplechanges discussed in the text will allow testing of any of thegenerally available operational amplifiers.
Amplifier parameters are tested over the full range of com-mon mode and power supply voltages with either of two out-put loads. Test set sensitivity and stability are adequate fortesting all presently available integrated amplifiers.
The paper will be divided into two sections, i.e., a functionaldescription, and a discussion of circuit operation. Completeconstruction information will be given including a layout forthe tester circuit boards.
FUNCTIONAL DESCRIPTION
The test set operates in one of three basic modes. Theseare: (1) Bias Current Test; (2) Offset Voltage, Offset CurrentTest; and (3) Transfer Function Test. In the first two of thesetests, the amplifier under test is exercised throughout its fullcommon mode range. In all three tests, power supply volt-ages for the circuit under test may be set at ±5V, ±10V,±15V, or ±20V.
POWER SUPPLY
Basic waveforms and dc operating voltages for the test setare derived from a power supply section comprising a posi-tive and a negative rectifier and filter, a test set voltage regu-lator, a test circuit voltage regulator, and a function genera-tor. The dc supplies will be discussed in the section dealingwith detailed circuit description.
The waveform generator provides three output functions, a±19V square wave, a −19V to +19V pulse with a 1% dutycycle, and a ±5V triangular wave. The square wave is thebasic waveform from which both the pulse and triangularwave outputs are derived.
The square wave generator is an operational amplifier con-nected as an astable multivibrator. This amplifier provides anoutput of approximately ±19V at 16 Hz. This square wave isused to drive junction FET switches in the test set and togenerate the pulse and triangular waveforms.
The pulse generator is a monostable multivibrator driven bythe output of the square wave generator. This multivibrator isallowed to swing from negative saturation to positive satura-tion on the positive going edge of the square wave input andhas a time constant which will provide a duty cycle of ap-proximately 1%. The output is approximately −19V to +19V.
The triangular wave generator is a dc stabilized integratordriven by the output of the square wave generator and pro-vides a ±5V output at the square wave frequency, invertedwith respect to the square wave.
The purpose of these various outputs from the power supplysection will be discussed in the functional description.
AN007190-1
FIGURE 1. Functional Diagram of Bias Current Test Circuit
National SemiconductorApplication Note 24M. YamatakeApril 1986
AS
implified
TestSetfor
Op
Am
pC
haracterizationA
N-24
AN
-24
© 1998 National Semiconductor Corporation AN007190 www.national.com 1
PrintDate=1998/04/24 PrintTime=08:34:00 39684 an007190 Rev. No. 3 cmservProof 1
BIAS CURRENT TEST
A functional diagram of the bias current test circuit is shownin Figure 1. The output of the triangular wave generator andthe output of the test circuit, respectively, drive the horizontaland vertical deflection of an oscilloscope.
The device under test, (cascaded with the integrator, A7), isconnected in a differential amplifier configuration by R1, R2,R3, and R4. The inputs of this differential amplifier are drivenin common from the output of the triangular wave generatorthrough attenuator R8 and amplifier A8. The inputs of the de-vice under test are connected to the feedback networkthrough resistors R5 and R6, shunted by the switch S5a andS5b.
The feedback network provides a closed loop gain of 1,000and the integrator time constant serves to reduce noise atthe output of the test circuit as well as allowing the output ofthe device under test to remain near zero volts.
The bias current test is accomplished by allowing the deviceunder test to draw input current to one of its inputs throughthe corresponding input resistor on positive going or nega-tive going halves of the triangular wave generator output.This is accomplished by closing S5a or S5b on alternatehalves of the triangular wave input. The voltage appearingacross the input resistor is equal to input current times the in-put resistor. This voltage is multiplied by 1,000 by the feed-back loop and appears at the integrator output and the ver-tical input of the oscilloscope. The vertical separaton of thetraces representing the two input currents of the amplifier un-der test is equivalent to the total bias current of the amplifierunder test.
The bias current over the entire common mode range maybe examined by setting the output of A8 equal to the amplifiercommon mode range. A photograph of the bias current oscil-loscope display is given as Figure 2. In this figure, the totalinput current of an amplifier is displayed over a ±10V com-mon mode range with a sensitivity of 100 nA per verticaldivision.
The bias current display of Figure 2 has the added advan-tage that incipient breakdown of the input stage of the deviceunder test at the extremes of the common mode range iseasily detected.
If either or both the upper or lower trace in the bias currentdisplay exhibits curvature near the horizontal ends of the os-cilloscope face, then the bias current of that input of the am-plifier is shown to be dependent on common mode voltage.The usual causes of this dependency are low breakdownvoltage of the differential input stage or current sink.
OFFSET VOLTAGE, OFFSET CURRENT TEST
The offset voltage and offset current tests are performed inthe same general way as the bias current test. The only dif-ference is that the switches S5a and S5b are closed on thesame half-cycle of the triangular wave input.
The synchronous operation of S5a and S5b forces the ampli-fier under test to draw its input currents through matchedhigh and low input resistors on alternate halves of the inputtriangular wave. The difference between the voltage dropacross the two values of input resistors is proportional to thedifference in input current to the two inputs of the amplifierunder test and may be measured as the vertical spacing be-tween the two traces appearing on the face of the oscillo-scope.
Offset voltage is measured as the vertical spacing betweenthe trace corresponding to one of the two values of sourceresistance and the zero volt baseline. Switch S6 and Resis-tor R9 are a base line chopper whose purpose is to providea baseline reference which is independent of test set and os-cilloscope drift. S6 is driven from the pulse output of the func-tion generator and has a duty cycle of approximately 1% ofthe triangular wave.
Figure 3 is a photograph of the various waveforms presentedduring this test. Offset voltage and offset current are dis-played at a sensitivity of 1 mV and 100 nA per division, re-spectively, and both parameters are displayed over a com-mon mode range of ±10V.
AN007190-2
FIGURE 2. Bias Current and CommonMode Rejection Display
AN007190-3
FIGURE 3. Offset Voltage, Offset Currentand Common Mode Rejection Display
PrintDate=1998/04/24 PrintTime=08:34:00 39684 an007190 Rev. No. 3 cmservProof 2
www.national.com 2
TRANSFER FUNCTION TEST
A functional diagram of the transfer function test is shown inFigure 4. The output of the triangular wave generator and theoutput of the circuit under test, respectively, drive the hori-zontal and vertical inputs of an oscilloscope.
The device under test is driven by a ±2.5 mV triangular wavederived from the ±5V output of the triangular wave generatorthrough the attenuators R11, R12, and R1, R3 and through thevoltage follower, A7. The output of the device under test isfed to the vertical input of an oscilloscope.
Amplifier A7 performs a dual function in this test. When S7 isclosed during the bias current test, a voltage is developedacross C1 equal to the amplifier offset voltage multiplied bythe gain of the feedback loop. When S7 is opened in thetransfer function test, the charge stored in C1 continues toprovide this offset correction voltage. In addition, A7 sumsthe triangular wave test signal with the offset correction volt-age and applies this sum to the input of the amplifier undertest through the attenuator R1, R3. This input sweeps the in-put of the amplifier under test ±2.5 mV around its offset volt-age.
Figure 5 is a photograph of the output of the test set duringthe transfer function test. This figure illustrates the functionof amplifier A7 in adjusting the dc input of the test device sothat its transfer function is displayed on the center of the os-cilloscope face.
The transfer function display is a plot of VIN vs VOUT for anamplifier. This display provides information about three am-plifier parameters: gain, gain linearity, and output swing.
Gain is displayed as the slope, ∆VOUT/∆VIN of the transferfunction. Gain linearity is indicated change in slope of theVOUT/VIN display as a function of output voltage. This displayis particularly useful in detecting crossover distortion in aClass B output stage. Output swing is measured as the ver-tical deflection of the transfer function at the horizontal ex-tremes of the display.
AN007190-4
FIGURE 4. Functional Diagram of Transfer Function Circuit
AN007190-5
FIGURE 5. Transfer Function Display
3 www.national.com
PrintDate=1998/04/24 PrintTime=08:34:01 39684 an007190 Rev. No. 3 cmservProof 3
DETAILED CIRCUIT DESCRIPTION
POWER SUPPLIES
As shown in Figure 6, which is a complete schematic of thepower supply and function generator, two power supplies areprovided in the test set. One supply provides a fixed ±20V topower the circuitry in the test set; the other provides ±5V to±20V to power the circuit under test.
The test set power supply regulator accepts +28V from thepositive rectifier and filter and provides +20V through the
LM100 positive regulator. Amplifier A1 is powered from thenegative rectifier and filter and operates as a unity gain in-verter whose input is +20V from the positive regulator, andwhose output is −20V.
The test circuit power supply is referenced to the +20V out-put of the positive regulator through the variable divider com-prising R7, R8, R9, R10, and R26. The output of this divider is+10V to +2.5V according to the position of S2a and is fed tothe non-inverting, gain-of-two amplifier, A2. A2 is poweredfrom +28V and provides +20V to +5V at its output. A3 is a
AN007190-6
NOTE: All resistor valves in ohms.All resistors 1⁄4W, 5% unless specified otherwise.
FIGURE 6. Power Supply and Function Generator
PrintDate=1998/04/24 PrintTime=08:34:01 39684 an007190 Rev. No. 3 cmservProof 4
www.national.com 4
unity gain inverter whose input is the output of A2 and whichis powered from −28V. The complementary outputs of ampli-fiers A2 and A3 provide dc power to the circuit under test.
LM101 amplifiers are used as A2 and A3 to allow operationfrom one ground referenced voltage each and to provideprotective current limiting for the device under test.
FUNCTION GENERATOR
The function generator provides three outputs, a ±19Vsquare wave, a −19V to +19V pulse having a 1% duty cycle,and a ±5V triangular wave. The square wave is the basicfunction from which the pulse and triangular wave are de-rived, the pulse is referenced to the leading edge of thesquare wave, and the triangular wave is the inverted and in-tegrated square wave.
Amplifier A4 is an astable multivibrator generating a squarewave from positive to negative saturation. The amplitude ofthis square wave is approximately ±19V. The square wavefrequency is determined by the ratio of R18 to R16 and by thetime constant, R17C9. The operating frequency is stabilizedagainst temperature and power regulation effects by regulat-ing the feedback signal with the divider R19, D5 and D6.
Amplifier A5 is a monostable multivibrator triggered by thepositive going output of A4. The pulse width of A5 is deter-mined by the ratio of R20 to R22 and by the time constantR21C10. The output pulse of A5 is an approximately 1% dutycycle pulse from approximately −19V to +19V.
Amplifier A6 is a dc stabilized integrator driven from theamplitude-regulated output of A4. Its output is a ±5V triangu-lar wave. The amplitude of the output of A6 is determined bythe square wave voltage developed across D5 and D6 andthe time constant Radj C14. DC stabilization is accomplishedby the feedback network R24, R25, and C15. The ac attenua-tion of this feedback network is high enough so that the inte-grator action at the square wave frequency is not degraded.
Operating frequency of the function generator may be variedby adjusting the time constants associated with A4, A5, andA6 in the same ratio.
TEST CIRCUIT
A complete schematic diagram of the test circuit is shown inFigure 7. The test circuit accepts the outputs of the powersupplies and function generator and provides horizontal andvertical outputs for an X-Y oscilloscope, which is used as themeasurement system.
The primary elements of the test circuit are the feedbackbuffer and integrator, comprising amplifier A7 and its feed-back network C16, R31, R32, and C17, and the differential am-plifier network, comprising the device under test and thefeedback network R40, R43, R44, and R52. The remainder ofthe test circuit provides the proper conditioning for the deviceunder test and scaling for the oscilloscope, on which the testresults are displayed.
The amplifier A8 provides a variable amplitude source ofcommon mode signal to exercise the amplifier under testover its common mode range. This amplifier is connected asa non-inverting gain-of-3.6 amplifier and receives its inputfrom the triangular wave generator. Potentiometer R37 al-lows the output of this amplifier to be varied from ±0 volts to±18 volts. The output of this amplifier drives the differentialinput resistors, R43 and R44, for the device under test.
The resistors R46 and R47 are current sensing resistorswhich sense the input current of the device under test. Theseresistors are switched into the circuit in the proper sequenceby the field effect transistors Q6 and Q7. Q6 and Q7 are
driven from the square wave output of the function generatorby the PNP pair, Q10 and Q11, and the NPN pair, Q8 and Q9.Switch sections S1b and S1c select the switching sequencefor Q8 and Q9 and hence for Q6 and Q7. In the bias currenttest, the FET drivers, Q8 and Q9, are switched by out ofphase signals from Q10 and Q11. This opens the FETswitches Q6 and Q7 on alternate half cycles of the squarewave output of the function generator. During the offset volt-age, offset current test, the FET drivers are operated syn-chronously from the output of Q11. During the transfer func-tion test, Q6 and Q7 are switched on continuously by turningoff Q11. R42 and R45 maintain the gates of the FET switchesat zero gate to source voltage for maximum conductanceduring their on cycle. Since the sources of these switchesare at the common mode input voltage of the device undertest, these resistors are connected to the output of the com-mon mode driver amplifier, A8.
The input for the integrator-feedback buffer, A7, is selectedby the FET switches Q4 and Q5. During the bias current andoffset voltage offset current tests, A7 is connected as an inte-grator and receives its input from the output of the device un-der test. The output of A7 drives the feedback resistor, R40.In this connection, the integrator holds the output of the de-vice under test near ground and serves to amplify the volt-ages corresponding to bias current, offset current, and offsetvoltage by a factor of 1,000 before presenting them to themeasurement system. FET switches Q4 and Q5 are turnedon by switch section S1b during these tests.
FET switches Q4 and Q5 are turned off during the transferfunction test. This disconnects A7 from the output of the de-vice under test and changes it from an integrator to anon-inverting unity gain amplifier driven from the triangularwave output of the function generator through the attenuatorR33 and R34 and switch section S1a. In this connection, am-plifier A7 serves two functions; first, to provide an offset volt-age correction to the input of the device under test and, sec-ond, to drive the input of the device under test with a ±2.5mV triangular wave centered about the offset voltage. Duringthis test, the common mode driver amplifier is disabled byswitch section S1a and the vertical input of the measurementoscilloscope is transferred from the output of theintegrator-buffer, A7, to the output of the device under test byswitch section S1d. S2a allows supply voltages for the deviceunder test to be set at ±5, ±10, ±15, or ±20V. S2b changesthe vertical scale factor for the measurement oscilloscope tomaintain optimum vertical deflection for the particular powersupply voltage used. S4 is a momentary contact pushbuttonswitch which is used to change the load on the device undertest from 10 kΩ to 2 kΩ.
A delay must be provided when switching from the inputtests to the transfer function tests. The purpose of this delayis to disable the integrator function of A7 before driving it withthe triangular wave. If this is not done, the offset correctionvoltage, stored on C16, will be lost. This delay between open-ing FET switch Q4, and switch Q5, is provided by the RC fil-ter, R35 and C19.
Resistor R41 and diodes D7 and D8 are provided to controlthe integrator when no test device is present, or when afaulty test device is inserted. R41 provides a dc feedbackpath in the absence of a test device and resets the integratorto zero. Diodes D7 and D8 clamp the input to the integrator toapproximately ±0.7 volts when a faulty device is inserted.
FET switch Q1 and resistor R28 provide a ground referenceat the beginning of the 50-ohm-source, offset-voltage trace.This trace provides a ground reference which is independentof instrument or oscilloscope calibration. The gate of Q1 is
5 www.national.com
PrintDate=1998/04/24 PrintTime=08:34:01 39684 an007190 Rev. No. 3 cmservProof 5
driven by the output of monostable multivibrator A5, andshorts the vertical oscilloscope drive signal to ground duringthe time that A5 output is positive.
Switch S3, R27, and R28 provide a 5X scale increase duringinput parameter tests to allow measurement of amplifierswith large offset voltage, offset current, or bias current.
Switch S5 allows amplifier compensation to be changed for101 or 709 type amplifiers.
CALIBRATION
Calibration of the test system is relatively simple and re-quires only two adjustments. First, the output of the mainregulator is set up for 20V. Then, the triangular wave genera-tor is adjusted to provide ±5V output by selecting Radj. Thissets the horizontal sweep for the X-Y oscilloscope used asthe measurement system. The oscilloscope is then set up for1V/division vertical and for a full 10 division horizontalsweep.
Scale factors for the three test positions are:
1. Bias Current Display (Figure 2)
Ibias total 100 nA/div. vertical
Common Mode Voltage Variable horizontal
2. Offset Voltage-Offset Current (Figure 3)
Ioffset 100 nA/div. vertical
Voffset 1 mV/div. vertical
Common Mode Voltage Variable horizontal
AN007190-7
Note: All resistors 1/4W, 5% unless specified otherwise *2N3819 matched for on resistance within 200Ω Select for BVGS > 45V
FIGURE 7. Test Circuit
PrintDate=1998/04/24 PrintTime=08:34:01 39684 an007190 Rev. No. 3 cmservProof 6
www.national.com 6
3. Transfer Function (Figure 5)
VIN 0.5 mV/div.
VOUT 5V/div. @ Vs ±20V
5V/div. @ Vs ±15V
2V/div. @ Vs ±10V
1V/div. @ Vs ±5V
CONSTRUCTION
Test set construction is simplified through the use of inte-grated circuits and etched circuit layout.
Figures 8, 9, 10 give photographs of the completed tester.Figure 11 shows the parts location for the components onthe circuit board layout of Figure 12. An attempt should bemade to adhere to this layout to insure that parasitic couplingbetween elements will not cause oscillations or give calibra-tion problems.
Table 1 is a listing of special components which are neededto fit the physical layout given for the tester.
TABLE 1. Partial Parts List
T1 Triad F-90X
S1 Centralab PA2003 non-shorting
S2 Centralab PA2015 non-shorting
S3, S4 Grayhill 30-1 Series 30 subminiaturepushbutton switch
S5, S6 Alcoswitch MST-105D SPDT
CONCLUSIONS
A semi-automatic test system has been described which willcompletely test the important operational amplifier param-eters over the full power supply and common mode ranges.The system is simple, inexpensive, easily calibrated, and isequally suitable for engineering or quality assurance usage.
AN007190-8
FIGURE 8. Bottom of Test Set
7 www.national.com
PrintDate=1998/04/24 PrintTime=08:34:02 39684 an007190 Rev. No. 3 cmservProof 7
AN007190-9
FIGURE 9. Front Panel
AN007190-10
FIGURE 10. Jacks
PrintDate=1998/04/24 PrintTime=08:34:02 39684 an007190 Rev. No. 3 cmservProof 8
www.national.com 8
AN007190-11
FIGURE 11. Component Location, Top View
9 www.national.com
PrintDate=1998/04/24 PrintTime=08:34:02 39684 an007190 Rev. No. 3 cmservProof 9
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DE-VICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF NATIONAL SEMI-CONDUCTOR CORPORATION. As used herein:1. Life support devices or systems are devices or sys-
tems which, (a) are intended for surgical implant intothe body, or (b) support or sustain life, and whose fail-ure to perform when properly used in accordancewith instructions for use provided in the labeling, canbe reasonably expected to result in a significant injuryto the user.
2. A critical component in any component of a life supportdevice or system whose failure to perform can be rea-sonably expected to cause the failure of the life supportdevice or system, or to affect its safety or effectiveness.
National SemiconductorCorporationAmericasTel: 1-800-272-9959Fax: 1-800-737-7018Email: [email protected]
www.national.com
National SemiconductorEurope
Fax: +49 (0) 1 80-530 85 86Email: [email protected]
Deutsch Tel: +49 (0) 1 80-530 85 85English Tel: +49 (0) 1 80-532 78 32Français Tel: +49 (0) 1 80-532 93 58Italiano Tel: +49 (0) 1 80-534 16 80
National SemiconductorAsia Pacific CustomerResponse GroupTel: 65-2544466Fax: 65-2504466Email: [email protected]
National SemiconductorJapan Ltd.Tel: 81-3-5620-6175Fax: 81-3-5620-6179
AN007190-12
FIGURE 12. Circuit Board Layout
AN
-24
AS
impl
ified
Test
Set
for
Op
Am
pC
hara
cter
izat
ion
10
PrintDate=1998/04/24 PrintTime=08:34:02 39684 an007190 Rev. No. 3 cmservProof 10
BookExtractEnd
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications.
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,and other changes to its products and services at any time and to discontinue any product or service without notice. Customers shouldobtain the latest relevant information before placing orders and should verify that such information is current and complete. All products aresold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standardwarranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except wheremandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products andapplications using TI components. To minimize the risks associated with customer products and applications, customers should provideadequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Informationpublished by TI regarding third-party products or services does not constitute a license from TI to use such products or services or awarranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectualproperty of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompaniedby all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptivebusiness practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additionalrestrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids allexpress and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is notresponsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonablybe expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governingsuch use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, andacknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their productsand any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may beprovided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products insuch safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products arespecifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet militaryspecifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely atthe Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products aredesignated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designatedproducts in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products Applications
Audio www.ti.com/audio Communications and Telecom www.ti.com/communications
Amplifiers amplifier.ti.com Computers and Peripherals www.ti.com/computers
Data Converters dataconverter.ti.com Consumer Electronics www.ti.com/consumer-apps
DLP® Products www.dlp.com Energy and Lighting www.ti.com/energy
DSP dsp.ti.com Industrial www.ti.com/industrial
Clocks and Timers www.ti.com/clocks Medical www.ti.com/medical
Interface interface.ti.com Security www.ti.com/security
Logic logic.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense
Power Mgmt power.ti.com Transportation and Automotive www.ti.com/automotive
Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video
RFID www.ti-rfid.com
OMAP Mobile Processors www.ti.com/omap
Wireless Connectivity www.ti.com/wirelessconnectivity
TI E2E Community Home Page e2e.ti.com
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265Copyright © 2011, Texas Instruments Incorporated