GHD | Report for TasWater - Carrick STP New Discharge Pipeline and Outfall , 32/17413 Appendix B – Pipeline and Outfall Design

Appendix B – Pipeline and Outfall Design · water and environment taswater taswater locality plan n.t.s. drawing list design philosophy to replace the existing outfall arrangement

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Appendix B – Pipeline and Outfall Design · water and environment taswater taswater locality plan n.t.s. drawing list design philosophy to replace the existing outfall arrangement

GHD | Report for TasWater - Carrick STP New Discharge Pipeline and Outfall , 32/17413

Appendix B – Pipeline and Outfall Design

Page 2: Appendix B – Pipeline and Outfall Design · water and environment taswater taswater locality plan n.t.s. drawing list design philosophy to replace the existing outfall arrangement

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateDrawnRevisionNo A1Original Size

Title

Project

Client

Check

DesignerDrawn

Scale

Design

Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Level 2, 102 Cameron St, Launceston TAS 7250 AustraliaPO Box 1269 Launceston TAS 7250T 61 3 6332 5500 F 61 3 6332 5555E [email protected] W www.ghd.com

Plot Date: Cad File No:21 October 2014 - 11:10 AM G:\32\17221\CADD\Drawings\32-17221-G001.dwgPlotted by: Jim Rogers

(Project Director)Approved

JobManager

ProjectDirector

PRELIMINARY

32-17221-G001 A

J. ROGERS E. GRUBER

AS SHOWN

Map data reproduced withthe permission of TASMAP

DEPARTMENT ofPRIMARY INDUSTRIES,

WATER and ENVIRONMENT

TasWater

TasWater

LOCALITY PLANN.T.S.

DRAWING LIST

DESIGN PHILOSOPHYTO REPLACE THE EXISTING OUTFALL ARRANGEMENT THAT SEES TREATEDEFFLUENT FROM THE CARRICK WWTP DISCHARGED INTO AN OPENCHANNEL THAT CONVEYS THE FLOW TO THE LIFFEY RIVER WHICH,IN TURN DISCHARGES INTO THE MEANDER RIVER.THE PROPOSED ARRANGEMENT WILL ALLOW TREATED EFFLUENTTO BE USED FOR IRRIGATION PURPOSES ON THE FARMING PROPERTY"THE MOAT" AND EXCESS TO BE DISCHARGED TO THE MEANDER RIVER.

MODES OF OPERATIONTHE PROPOSED SCHEME WILL OPERATE UNDER A NUMBER OF SCENARIOS. THESEINCLUDE THE FOLLOWING MODES OF OPERATION:1. REUSE IRRIGATION - TREATED EFFLUENT TO IRRIGATION PUMP FOR USE BYPROPERTY OWNER FOR IRRIGATION.2. OUTFALL - TREATED EFFLUENT TO THE OUTFALL IN THE MEANDER RIVER.3. STORAGE - TREATED EFFLUENT TO FILL THE WWTP STORAGE LAGOON4. EMERGENCY - TREATED EFFLUENT TO OPEN CHANNELSYSTEM CONTROLS WILL PERMIT ONLY ONE MODE OF OPERATION AT A TIME.TREATED EFFLUENT STORAGE LAGOON ( TESL ) = 25MLWWTP AVERAGE DAILY FLOW ( THROUGHPUT ) = 0.5 TO 0.6ML / DAY ( 5.8 TO 6.9 L/S )ESTIMATED TIME TO FILL THE TESL FROM EMPTY = 50 DAYS TO 42 DAYSESTIMATED AVERAGE FLOW DELIVERED TO IRRIGATION PUMP = 42 L/SESTIMATED NETT EMPTYING RATE OF TESL = 36.2 TO 35.1 L/SESTIMATED TIME TO EMPTY THE TESL FROM FULL = 8 DAYS TO 8.2 DAYS

DESIGN BASISREFER TO DESIGN BASIS REPORT JULY 2014 ( GHD ) DTC 32/17221/614561

DRAWING No. DRAWING TITLE32-17221-G001 COVER PAGE, LOCALITY PLAN & DRAWING LIST32-17221-J001 PROCESS & INSTRUMENTATION DIAGRAM32-17221-C00132-17221-C002

PLAN & LONGITUDINAL SECTION - SHEET 1 OF 3

32-17221-C003PLAN & LONGITUDINAL SECTION - SHEET 2 OF 3

32-17221-C004PLAN & LONGITUDINAL SECTION - SHEET 3 OF 3

32-17221-C005PIPEWORK DETAILS - MEANDER RIVER OUTFALL

32-17221-C006

CONNECTION TO EXIST. IRRIGATION WET WELL32-17221-C007 FLOW CONTROL VALVE & FLOW METER CHAMBER32-17221-C008

TYPICAL TRENCH SECTION, GAS MAIN CROSSING

32-17221-S001

CARRICK WWTP

OUTFALL

PROPOSED PIPELINE

TASWATER REFERENCE DRAWINGSBLW G-100 TRENCH REINSTATEMENTS - FLEXIBLE PAVEMENTS

CONNECTION TO WWTP PIPEWORK

FLOW CONTROL VALVE & FLOW METER CHAMBERSTRUCTURAL DETAILS

GENERAL NOTES FOR PIPEWORK

1. TAKE MEASURES TO PREVENT THERMALEXPANSION/CONTRACTION OF THE PIPELINE DURINGINSTALLATION. FOLLOW SUPPLIERS GUIDELINES TOPREVENT POST INSTALLATION FAILURES CAUSED BYTHERMAL EXPANSION/CONTRACTION.2. PIPELINE AUTHORITY MARKER POSTS TO BEINSTALLED AT ALL CHANGES OF DIRECTION & ATFENCELINES. REFER WSAA STANDARD DWG WAT-1300.MARKER POSTS TO BE "DURA-POST REG. DESIGN131212", LABEL TO BE ADVISED.3. ALL SUBSURFACE BOLTS AND NUTS TO BE GRADE316 CLASS 50 (MIN) STAINLESS STEEL. ENSURETHREADS ARE CLEAN & FREE OF GRIT. APPLY ANANTI-SEIZE COMPOUND LIBERALLY TO ALL THREADS.4. INSTALL LOOSE POLYETHELENE SLEEVING(EXTERNAL PROTECTION) TO ALL DI PIPES AND FITTINGSINSTALLED BELOW GROUND.5. INSULATE ALL DISSIMILAR METALS .6. CONFINE WORK UNDER THE CONTRACT TO WITHINTHE ROAD RESERVATIONS, LIMITS OF SITE OREASEMENTS SHOWN ON THE DRAWINGS.

7. SURVEY PROVIDED BY:BULLOCK CONSULTING287 CHARLES STREET, LAUNCESTON, TAS 7250PH: 03 6332 3300CO-ORDINATE DATUM IS PLANE BASED ON MGA( GDA94 ) AT SPM 8240E 502459.105, N 5402933.853, RL 142.368 THE HEIGHT DATUM IS AHD 83 ( TAS )8. ALL PIPEWORK SETOUT TO BE CARRIED OUT BY ALICENSED SURVEYOR.9. ALL PE BENDS TO BE THE SAME PN RATING ORHIGHER AS ADJACENT PE PIPE.10. ROTATE HORIZONTAL BENDS TO PROVIDEVERTICAL DEFLECTION AS REQUIRED.11. TRACKER MARKER TAPE TO BE INSTALLED OVERALL PIPELINES. TAPE TO BE INSTALLED BETWEENOVERLAY MATERIAL AND REFILL.12. USE "LILAC" COLOUR CODING FOR ALL REUSEPIPEWORK.

32-17221-S002 MODIFICATIONS TO EXISTING PUMP PLATFORM14070-S1-E01 ELECTRICAL SERVICES LAYOUTS14070-S1-E02 FLOW CONTROL VALVE LAYOUT14070-S1-E03 PLATFORM LAYOUTS14070-S1-E04 SCHEMATICS

AIR VALVE DETAIL AND AIR VENT DETAIL

Page 3: Appendix B – Pipeline and Outfall Design · water and environment taswater taswater locality plan n.t.s. drawing list design philosophy to replace the existing outfall arrangement

LSHLSL

M

RM

LEGEND

MOTORPUMP (ELECTRIC)LEVEL SENSOR HIGHLEVEL SENSOR LOW

RISING MAINVALVE OPENVALVE CLOSEDNON-RETURN VALVE

NEW WORKS SHOWN BOLDCONTROL VALVE - SOLENOID

S

RL REDUCED LEVEL (AHD)

AIR VALVE

M

FLOW METER

CARRICK WWTP

PLC PROGRAMMABLE LOGIC CONTROLLER

PLC

"C"

CARRICK WWTP TREATEDEFFLUENT STORAGE LAGOON

TWL 135.7

FL 132.5BWL 133.2

RL 136.0 WEIR CREST

WEIR CHAMBER

OVERFLOW PIPELINE

GAS M

AIN CR

OSSIN

G

LEVELS TAKEN FROM AS CONSTRUCTED DRAWINGS BY CEE PTY. LTD. ( CIRA 2000 )TWL TO BE CHECKED / CONFIRMED ON SITE ANDADJUSTED ACCORDINGLY TO ENSURE SPILLS DO NOTOCCUR VIA OVERFLOW PIPELING

*

* *

*

MEANDER RIVER

RL 127.3 ( 6/3/13 )

FM 2

FM 1S

S

"A"

"B"

INFRASTRUCTURE OWNED AND OPERATEDBY "THE MOAT" PROPERTY

S

RISING MAIN TOCENTRE PIVOT

"PUMP" RL124.85

RL127.30RL128.70RL129.88

( 6/3/13 )

SCENARIO MODES OF OPERATION

1. RE-USE - TREATED EFFLUENT TO IRRIGATION PUMP

VALVE "A" VALVE "B" VALVE "C"

OPENED CLOSED OPENED MEASURING NOT MEASURING

2. OUTFALL - TREATED EFFLUENT TO OUTFALL( FILL EFFLUENT STORAGE LAGOON & SURPLUS TO OUTFALL )

CLOSED OPENED OPENED NOT MEASURING MEASURING

3. STORAGE - TREATED EFFLUENT TO FILL STORAGE LAGOON CLOSED CLOSED OPENED NOT MEASURING NOT MEASURING

4. EMERGENCY - TREATED EFFLUENT TO OPEN CHANNEL CLOSED NOT MEASURING NOT MEASURING( OUTFALL PIPELINE OUT OF SERVICE )

FLOWMETER 1 FLOWMETER 2"PUMP"

ON

OFF

OFF

ON OR OFF

SIGNAL TO OPEN CONTROL VALVE "B" WHEN LEVEL SENSOR DETECTS EFFLUENT STORAGE LAGOON IS FULL I.E. AT TWL

SIGNAL TO CLOSE CONTROL VALVES "A" & "B" WHEN LEVEL SENSOR DETECTS EFFLUENT STORAGE LAGOON IS NOT FULL I.E. BELOW TWL

( EXISTING VALVE )

AIR RE

LEAS

E VEN

T

" THE MOAT" IRRIGATIONPUMPING STATION

"D"

VALVE "D" - FLOW LIMITING VALVE( TO BE SET DURING COMMISSIONINGTO LIMIT FLOW TO 10 l/s )

FM

EMERGENCY TO OPEN CHANNEL DN225 PE OUTFALL PIPELINE

AIR VA

LVE

SCOU

R TEE

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateDrawnRevisionNo A1Original Size

Title

Project

Client

Check

DesignerDrawn

Scale

Design

Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Level 2, 102 Cameron St, Launceston TAS 7250 AustraliaPO Box 1269 Launceston TAS 7250T 61 3 6332 5500 F 61 3 6332 5555E [email protected] W www.ghd.com

Plot Date: Cad File No:21 October 2014 - 11:11 AM G:\32\17221\CADD\Drawings\32-17221-J001.dwgPlotted by: Jim Rogers

(Project Director)Approved

JobManager

ProjectDirector

PRELIMINARY

32-17221-J001 A

J. ROGERS E. GRUBER

N.T.S.

TasWater

Page 4: Appendix B – Pipeline and Outfall Design · water and environment taswater taswater locality plan n.t.s. drawing list design philosophy to replace the existing outfall arrangement

CH 0.0

0

CH 10

0.00

CH 20

0.00

CH 30

0.00

PI: 1.07

PI: 9.55

PI: 20

2.12

BC: 14

5.12

EC: 15

3.45

EFFLUENT PONDS

STORAGE POND

TEMPORARY ELECTRIC FENCE ONLY

SWSW

CH 32

0.00

CH 12

1.39

LIMIT OF SITE

LIMIT OF SITE

LIMIT OF SITE

20.00m

20.00m

==

R15.00

L1L2

L3

L4

L5

C1

DATUM 125.000PIPE LENGTH (m)PIPE GRADE (%)

DEPTH TO INVERT

PIPE INVERT LEVEL

EXISTING SURFACE LEVEL

CHAINAGE

LAGOON_OUTFALL LONG SECTION

L: 320.000mG: -0.40%

133.33

4

133.49

5

-1.334

-2.695

132.00

0

130.80

0

0.000

300.00

0

DIAMETER & MATERIAL DN225 PE100 PN6.3

TWL 135.7

BWL 133.2

HGL - NO FLOWSTATIC

HGL - Q 50 L/s @ 1.48 m/sTWL ˜̃

HGL - Q 30 L/s @ 0.90 m/sBWL ˜̃

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateDrawnRevisionNo A1Original Size

Title

Project

Client

Check

DesignerDrawn

Scale

Design

Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Level 2, 102 Cameron St, Launceston TAS 7250 AustraliaPO Box 1269 Launceston TAS 7250T 61 3 6332 5500 F 61 3 6332 5555E [email protected] W www.ghd.com

Plot Date: Cad File No:21 October 2014 - 11:12 AM G:\32\17221\CADD\Drawings\32-17221-C001_C003.dwgPlotted by: Jim Rogers

(Project Director)Approved

JobManager

ProjectDirector

PRELIMINARY

32-17221-C001 A

G. SCOLYER E. GRUBER

AS SHOWN

LONGITUDINAL SECTIONSCALE 1:500 H 1:100V

PLANSCALE 1:500

0 1 4 5m32

SCALE 1:100 AT ORIGINAL SIZE0 5 20 25m1510

SCALE 1:500 AT ORIGINAL SIZE

EXISTING GROUNDWATERMONITORING BORE

APPROXIMATE LOCATION OFEXISTING SUBSOIL DRAINS

AIR RELEASE VENT2C006

AIR RE

LEAS

E VEN

TCO

NNEC

T TO E

XISTIN

G 2C006

1C005

1C005

SCOUR TEE5

C006

SUBS

OIL DR

AIN

CARRICK WWTP

TasWater

PROPOSED DN225 PE100PN6.3 OUTFALL PIPELINE

TBM PEG BRL 134.71

Page 5: Appendix B – Pipeline and Outfall Design · water and environment taswater taswater locality plan n.t.s. drawing list design philosophy to replace the existing outfall arrangement

CH 30

0.00

CH 40

0.00

CH 50

0.00

CH 60

0.00

BC: 46

5.41

BC: 48

2.83

BC: 58

2.05

BC: 61

4.24

EC: 46

7.01

EC: 48

4.76

EC: 58

3.88

EC: 62

1.51

W

W

WCH 32

0.00

LIMIT OF SITE

LIMIT OF SITE

20.00m==

R15.00

R15.00

R15.00

R15.00

L5L6 L7 L8C2 C3

C4C5

DATUM 125.000PIPE LENGTH (m)PIPE GRADE (%)

DEPTH TO INVERT

PIPE INVERT LEVEL

EXISTING SURFACE LEVEL

CHAINAGE

LAGOON_OUTFALL LONG SECTION

L: 320.000mG: -0.40%

L: 170.000G: 0.532%

L: 130.000mG: -0.40%

133.49

5

133.30

9

133.15

1

132.66

4

-2.695

-2.589

-1.526

-1.564

130.80

0

130.72

0

131.62

5

131.10

0

300.00

0

320.00

0

490.00

0

620.00

0

GAS PIPELINE

DIAMETER & MATERIAL DN225 PE100 PN6.3

HGL - NO FLOWSTATIC

HGL - Q 50 L/s @ 1.48 m/sTWL ˜̃

HGL - Q 30 L/s @ 0.90 m/sBWL ˜̃

PROVIDE COMPACTEDGRAVEL BACKFILL UNDER

ACCESS TRACK

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateDrawnRevisionNo A1Original Size

Title

Project

Client

Check

DesignerDrawn

Scale

Design

Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Level 2, 102 Cameron St, Launceston TAS 7250 AustraliaPO Box 1269 Launceston TAS 7250T 61 3 6332 5500 F 61 3 6332 5555E [email protected] W www.ghd.com

Plot Date: Cad File No:21 October 2014 - 11:13 AM G:\32\17221\CADD\Drawings\32-17221-C001_C003.dwgPlotted by: Jim Rogers

(Project Director)Approved

JobManager

ProjectDirector

PRELIMINARY

32-17221-C002 A

G. SCOLYER E. GRUBER

AS SHOWN

0 1 4 5m32

SCALE 1:100 AT ORIGINAL SIZE0 5 20 25m1510

SCALE 1:500 AT ORIGINAL SIZE

LONGITUDINAL SECTIONSCALE 1:500 H 1:100V

PLANSCALE 1:500

4C006

SCOUR TEE5

C006

APPROXIMATE LOCATION OFEXISTING SUBSOIL DRAINSTYPICAL

APPROXIMATE LOCATION OFEXISTING GAS MAIN

AIR VALVE # 3C006

PROPOSED DN225 PE100PN6.3 OUTFALL PIPELINE

4C006

SUBS

OIL DR

AIN

5C006

3C006

AIR VALVE #

SUBS

OIL DR

AIN

# - AIR VALVE LEAKAGE ANTICIPATED(ONLY WHEN H.G.L. PASSES THROUGH AIR VALVE)

EXIST. PIVOT IRRIGATOR

TasWaterTasWaterTasWater

TBM BOLT CRL 133.25

Page 6: Appendix B – Pipeline and Outfall Design · water and environment taswater taswater locality plan n.t.s. drawing list design philosophy to replace the existing outfall arrangement

CH 0.0

0CH

10.00

CH 20

.00

CH 778.94

CH 600.00

CH 70

0.00

PI: 775.86

BC: 582.05

BC: 614.24

EC: 583.88

EC: 62

1.51

MEANDER RIVERW

WW

WW

WW

WW

WW

WW

LIMIT OF SITE

LIMIT OF SITE

20 .00m

R15.00

==

L8

L10

L9

C5

DATUM 125.000PIPE LENGTH (m)PIPE GRADE (%)

DEPTH TO INVERT

PIPE INVERT LEVEL

EXISTING SURFACE LEVEL

CHAINAGE

L: 40.000mG: -2.48%

L: 119.089mG: -1.21%

132.66

4

131.27

4

-1.564

-1.168

131.10

0

130.10

6

128.66

2

620.00

0

660.00

0

779.08

9

DIAMETER & MATERIAL DN225 PE100 PN6.3

HGL - NO FLOWSTATIC

SETOUT TABLETag

L1

L2

L3

C1

L4

L5

C2

L6

C3

L7

C4

L8

C5

L9

L10

BPEPBPEPBPEPTPIPTPBPEPBPEPTPIPTPBPEPTPIPTPBPEPTPIPTPBPEPTPIPTPBPEPBPEP

CHAINAGE0+000.000+001.070+001.070+009.550+009.550+145.12

0+145.120+153.45

0+153.450+202.120+202.120+465.41

0+465.410+467.01

0+467.010+482.83

0+482.830+484.76

0+484.760+582.05

0+582.050+583.88

0+583.880+614.24

0+614.240+621.51

0+621.510+775.860+775.860+778.94

NORTHING5402970.45635402969.72255402969.72255402976.18195402976.18195403064.7273

5403064.72735403071.5946

5403071.59465403118.03845403118.03845403373.0090

5403373.00905403374.5380

5403374.53805403389.3477

5403389.34775403391.1929

5403391.19295403485.9167

5403485.91675403487.6643

5403487.66435403516.1624

5403516.16245403522.1277

5403522.12775403625.52405403625.52405403627.7051

EASTING501273.9113501273.1357501273.1357501267.6365501267.6365501370.2963

501370.2963501374.8111

501374.8111501389.3861501389.3861501455.0366

501455.0366501455.5188

501455.5188501461.0753

501461.0753501461.6352

501461.6352501483.8443

501483.8443501484.3680

501484.3680501494.8353

501494.8353501498.8672

501498.8672501613.4653501613.4653501615.6464

LENGTH

1.068

8.483

135.570

8.325

48.677

263.287

1.604

15.818

1.930

97.293

1.825

30.360

7.271

154.349

3.085

RADIUS

15.000

15.000

15.000

15.000

15.000

BEARING

S46° 35' 12.31"W

N40° 24' 35.33"W

N49° 13' 18.54"E

N33° 19' 20.42"E

N17° 25' 22.31"E

N14° 26' 20.54"E

N17° 30' 08.81"E

N20° 33' 57.07"E

N16° 52' 50.11"E

N13° 11' 43.15"E

N16° 40' 54.12"E

N20° 10' 05.08"E

N34° 03' 17.38"E

N47° 56' 29.68"E

N45° 00' 00.00"E

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateDrawnRevisionNo A1Original Size

Title

Project

Client

Check

DesignerDrawn

Scale

Design

Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Level 2, 102 Cameron St, Launceston TAS 7250 AustraliaPO Box 1269 Launceston TAS 7250T 61 3 6332 5500 F 61 3 6332 5555E [email protected] W www.ghd.com

Plot Date: Cad File No:21 October 2014 - 11:13 AM G:\32\17221\CADD\Drawings\32-17221-C001_C003.dwgPlotted by: Jim Rogers

(Project Director)Approved

JobManager

ProjectDirector

PRELIMINARY

32-17221-C003 A

G. SCOLYER E. GRUBER

AS SHOWN

0 1 4 5m32

SCALE 1:100 AT ORIGINAL SIZE0 5 20 25m1510

SCALE 1:500 AT ORIGINAL SIZE

LONGITUDINAL SECTIONSCALE 1:500 H 1:100V

PLANSCALE 1:500

EXISTING PIVOT IRRIGATOR

EXISTING DN200 PE IRRIGATION MAIN

PROPOSED DN225 PE100PN6.3 OUTFALL PIPELINE

FLOW CHAMBER6C007

OUTFALL PIPELINEREFER DRG. 32-17221-C004

CONNECTION TO EXISTINGIRRIGATION WELL

7C008

APPROXIMATE LOCATION OFEXISTING SUBSOIL DRAINSTYPICAL

- LOCATION AND INVERT LEVELS ATTHESE LOCATIONS ARE CRITICAL

*

*

*

FLOW

CHAM

BER

TasWater

TBM BOLT CRL 133.25

6C007

Page 7: Appendix B – Pipeline and Outfall Design · water and environment taswater taswater locality plan n.t.s. drawing list design philosophy to replace the existing outfall arrangement

W

W

W

GENERALLY ROCKY BOTTOM

EXISTING IRRIGATION

RISING MAIN

MEANDERRIVER

DN200 PE100 PN16

DN100 PVC DRAIN PIPEAND HEADWALL

E 501615.700N 5403626.463

E 501615.867N 5403631.387

CH -1.60

CH. 0 .00

CH. 10 .0 0

CH. 20. 00

CH. 1 5.0 0

8 No. PRECASTCONCRETE ANCHORBLOCKS

PLANSCALE 1:200

CH. 30. 00

CH. 34. 70

2-

3-

4-

DN200 x 45° SWEPTBEND

PIPE LENGTHPIPE GRADE / RADIUS

DEPTH TO INVERT

INVERT LEVEL

EXISTING SURFACE LEVEL

CHAINAGE

-1.107

128.70

0129

.807

125.84

8

125.82

5

0.000

20.000

30.000

L: 2.584mG: 0%

L: 19.240mG: VARIES

L: 4.570mG: -31.167%

MEANDER RIVERWL 127.3 (06/06/13)

-1.600

129.80

1CE

NTRE

45° S

WEPT

BEND

OUTFALL PIPE LONGITUDINAL SECTIONSCALE 1:200

128.70

0

-1.063

128.70

0129

.763

2.584

L: 4.463mR: 15m

L: 3.660mR: 15m

-0.980

128.02

1129

.001

7.048

-1.112

128.02

1126

.596

11.617

0.125

125.93

8125

.813

15.277

125.92

333.

300

15.000

11.5°

SWEP

T BEN

D

OUTL

ET PO

RT

OUTL

ET PO

RT

OUTL

ET PO

RT

OUTL

ET PO

RT

17.450

22.450

27.450

32.450

34.7008.500

500

500 600 500

250300

180

R120

GALV. SWIFT LIFTANCHORS

PRECAST CONCRETE ANCHORBLOCKS CAST TO SIZE & SHAPEAS SHOWN 3 No.fc = 32Mpa, 50 COVER

240

B-

SECTIONA- 10SCALE 1 :

SECTIONB- 10SCALE 1 :

50 50ANCHOR BLOCK RESTRAINTTIOP HALF OF PIPE ONLYWELD 25mm THICK 80mm FLANGETO PIPE

EXCAVATE RIVER BED UNDER ANCHOR BLOCKS TO180mm DEEP OR TO FIRM FOUNDATION OR ROCKEXTEND UNDERSIDE PROFILE

PERMITTED TO SUIT RIVER BEDN12 EF AND CENTRAL

DN200 PE100 PN16 PIPE DN200 STUB FLANGE ANDS/S BACKING RING

DETAIL1- 20SCALE 1 :

( DISMANTLING JOINT )

WL. 127.30200

RL 127.50 45.00°

SECTIONC- 10SCALE 1 :

OUTLET PORT

PRECAST CONCRETE ANCHOR BLOCK

4No. OUTLET PORTS AT5m CENTRESDN110 PE100 PN16

FIRST OUTLET PORTDN200 x DN110 TEE( BUTT WELD ) LAST OUTLET PORT

DN200 STUB FLANGEAND S/S BACKING RING

DN200 STUB FLANGEAND S/S BACKING RINGWITH BLANK END

DN200 PE100 PN16 PIPELINE11.5° HORIZONTAL BEND

ANCHOR BLOCK RESTRAINTWELD 25mm THICK 80mm FLANGETO PIPE (TYPICAL)

DETAIL3- 20SCALE 1 :

A-

1500 2000 1500

5000

C-

600

DETAIL2- 20SCALE 1 :

TYPICAL TYPICAL TYPICAL

DETAIL4- 20SCALE 1 :

CH'GE 15.00

CH'GE 34.70

OUTLET PORT DN200 x DN110 TEE( BUTT WELD )

1500 TO CENTRE OF 1500 7501500 TO CENTRE OFNEXT ANCHOR BLOCKNEXT ANCHOR BLOCK

1500950

DIREC

TION

OF FL

OWNOTE:CONTRACTOR IS TO CHECK THE EXISTING SITE CONDITIONS ANDPIPELINE SET OUT PRIOR TO FABRICATION / CONSTRUCTION.

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateDrawnRevisionNo A1Original Size

Title

Project

Client

Check

DesignerDrawn

Scale

Design

Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Level 2, 102 Cameron St, Launceston TAS 7250 AustraliaPO Box 1269 Launceston TAS 7250T 61 3 6332 5500 F 61 3 6332 5555E [email protected] W www.ghd.com

Plot Date: Cad File No:21 October 2014 - 3:42 PM G:\32\17221\CADD\Drawings\32-17221-C004.dwgPlotted by: Jim Rogers

(Project Director)Approved

JobManager

ProjectDirector

PRELIMINARY

32-17221-C004 A

G. SCOLYER E. GRUBER

AS SHOWN

0 200 800 1000mm600400

SCALE 1:20 AT ORIGINAL SIZE

0 2 8 10m64

SCALE 1:200 AT ORIGINAL SIZE

1-

6C007

REFER DRG. 32-17221-C003FOR CONTINUATION

FLOW CHAMBER

7C008

PIPELINE SETOUT POINTSCHAINAGE EASTING NORTHING DESCRIPTION

CH. 0 501618.729 5403630.788 CENTRE 45° BENDCH. 15 501633.659 5403631.571 CENTRE 11.5° BEND

CH. 34.7 501652.732 5403636.548 END OF PIPELINE

0 100 400 500mm300200

SCALE 1:10 AT ORIGINAL SIZE

Page 8: Appendix B – Pipeline and Outfall Design · water and environment taswater taswater locality plan n.t.s. drawing list design philosophy to replace the existing outfall arrangement

DETAIL AT EFFLUENT STORAGE LAGOONSCALE 1 : 50

133.641

132.921

133.024

STORAGE LAGOON

TO DISCHARGE - IRRIGATOR / MEANDER RIVER

EXISTING OUTLETMANHOLE

NEW DN225 PE100 PN6.3 PIPE

EXIST. DN225 OUTFALL PIPES

EXISTING DN450 RCP OUTLET PIPE

GRADE APPROX. 1 IN 29.5

NEW DN225 PE100 PN6.3 PIPE

EXIST. POST & WIRE FENCE

DEFLECT PIPE AS REQUIREDTO SUIT ALIGNMENT

EXIST. DN200 JOHN FIG. 637SLUICE VALVE

EXIST. DN200 JOHN FIG. 630SLUICE VALVE

DN225 PE SWEPT BEND 90°

DN225 STUB FLANGE & S/SBACKING RING ( CONFIRMEXIST. FLANGE TABLE )

I.L. 131.65

DEFLECT PIPE AS REQUIREDTO SUIT ALIGNMENT

I.L. 132.00

I.L. 131.65

EXIST. DN200 DICL PIPE

1.11

FROM EFFLUENT

AIR RELEASE VENT2C006

1C001

NEW PIPELINE TO PASS OVER EXISTINGOUTFALL PIPES ( DETERMINE LEVEL OFEXISTING PIPES PRIOR TO ANYCONSTRUCTION )

EXISTIN

G DN450 RCP OUTLE

T PIPE

THRUST BLOCK

THRUST BLOCK

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateDrawnRevisionNo A1Original Size

Title

Project

Client

Check

DesignerDrawn

Scale

Design

Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Level 2, 102 Cameron St, Launceston TAS 7250 AustraliaPO Box 1269 Launceston TAS 7250T 61 3 6332 5500 F 61 3 6332 5555E [email protected] W www.ghd.com

Plot Date: Cad File No:21 October 2014 - 11:15 AM G:\32\17221\CADD\Drawings\32-17221-C005.dwgPlotted by: Jim Rogers

(Project Director)Approved

JobManager

ProjectDirector

PRELIMINARY

32-17221-C005 A

J. ROGERS E. GRUBER

AS SHOWN

0

SCALE 1:50 AT ORIGINAL SIZE

0.5 2.0 2.5m1.51.0

TasWater

N

Page 9: Appendix B – Pipeline and Outfall Design · water and environment taswater taswater locality plan n.t.s. drawing list design philosophy to replace the existing outfall arrangement

TYPICAL TRENCH SECTIONSCALE 1 : 10

ELECTROMAGNETIC INDICATORTAPE "LILAC COLOUR" WITHS/S WIRE TRACE

600

150150

TREN

CH RE

FILL

TOPSOIL TO BE REMOVED AND STOREDSEPARATELY FROM ( DEEPER ) TRENCHMATERIAL. REINSTATE TOP SOIL TOMATCH SURROUND

EXCAVATED MATERIAL

EMBEDMENT ( BEDDING, SIDE SUPPORT ANDOVERLAY )

NOTE: REFER TO BEN LOMOND WATER ST'D DRAWING G-100FOR BEDDING, HAUNCHING AND OVERLAYMATERIALS, COMPACTION AND TRENCH WIDTH.

REFE

R TO L

ONGIT

UDINA

L SEC

TION

FOR PE PIPE USE SAND OR CRUSHED ROCK MATERIALGRADUATION AS PER TABLE 3.

1100 C

OVER

NOM.

1080 N

OM.

100 MI

N.

CONCRETE SUPPORT

DN225 x DN90 REDUCING TEE

DN90 STUB FLANGE, GASKETAND S/S BACKING RING

DN80 DI PIPE FL-FL

ICON SEPTECH CIRCULAR GRATE320G6D, OR APPROVED EQUIVALENTMANHOLE SURROUND TO SUIT

1050 ID MANHOLE SHAFT

DN50 AVK DOUBLE ORIFICEAIR VALVE PN16, SERIES 851/10COLOUR "LILAC"

DN80-DN50TAPER DN80 HYDRANT / AIR VALVE

ISOLATOR, COLOUR "LILAC"

AIR VALVE DETAILSCALE 1 : 20

CONCRETE FOOTING

2 N12 TOP & BOTTOM

600200

150

150 150

NOM. 20 DIA SINGLE SIZE METALINFILL

CONCRETE SUPPORT

DN225 x DN90 REDUCING TEEDN90 STUB FLANGE, GASKETAND S/S BACKING RING

RL 136.65

DN80 DI PIPE FL - SP

FABRICATED 316 S/S MESH COVERNOM. 20mm OPENINGS

RL 133.30 APPROX.

400

200 200

AIR RELEASE VENT DETAILSCALE 1 : 20

CONCRETE SUPPORT BLOCK

DETAIL AT GAS MAIN CROSSINGSCALE 1 : 20

1200 T

O 1500

COVE

R

1800 M

IN.

300 MI

N.

PRECAST CONCRETE PROTECTIONSLABS, NOM. 800 LONG x 60 THICK,600 EITHER SIDE OF OUTFALL MAIN

EXISTING 200 DIA. GAS MAIN

DN225 PE100 PN6.3 PIPE LENGTHTO BE MIN. WIDTH OF THE GAS MAINTRENCH

200 MI

N.

EXIST. TRENCH

SCOUR TEE DETAILSCALE 1 : 20

800

CONCRETE SUPPORT

DN225 PE100 PN6.3 PIPE

DN225 x DN225 TEE

100 MI

N.

DN225 PE100 PN6.3 PIPE

DN225 STUB FLANGE, GASKETS/S BACKING RING & BLANKFLANGE, COLOUR "LILAC" ICON SEPTECH CIRCULAR GRATE

320G6D, OR APPROVED EQUIVALENTMANHOLE SURROUND TO SUIT

1050 ID MANHOLE SHAFT

CONCRETE FOOTING

150

150

2 N12 TOP & BOTTOM

600200

150

150 150

1 N12, R10 LIGS - 250NOM. 20 DIA SINGLE SIZE METALINFILL

NOTES: 1. ALL PE PIPE JOINTS TO BE BUTT WELDED2. WRAP DN80 RISER TO AIR VALVE WITH 20mm POLILAG

WHERE IT IS ENCASED IN THE CONCRETE BASE

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateDrawnRevisionNo A1Original Size

Title

Project

Client

Check

DesignerDrawn

Scale

Design

Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Level 2, 102 Cameron St, Launceston TAS 7250 AustraliaPO Box 1269 Launceston TAS 7250T 61 3 6332 5500 F 61 3 6332 5555E [email protected] W www.ghd.com

Plot Date: Cad File No:21 October 2014 - 11:16 AM G:\32\17221\CADD\Drawings\32-17221-C006.dwgPlotted by: Jim Rogers

(Project Director)Approved

JobManager

ProjectDirector

PRELIMINARY

32-17221-C006 A

J. ROGERS E. GRUBER

AS SHOWN

TasWater

2

4C002

3C002 5

C002

C001 - C005

0 200 800 1000mm600400

SCALE 1:20 AT ORIGINAL SIZE

0 100 400 500mm300200

SCALE 1:10 AT ORIGINAL SIZE

Page 10: Appendix B – Pipeline and Outfall Design · water and environment taswater taswater locality plan n.t.s. drawing list design philosophy to replace the existing outfall arrangement

PLAN OF TOPSCALE 1 : 20

A-

SECTIONA- 20SCALE 1 :

FITTINGS SCHEDULE1. DN225 PE STUB FLANGE AND S/S BACKING RING2.3.4.5.6.7.8.9.

10.11.12.13.14.

DN225 - DN200 DI TAPER, FL-FL ECCENTRICDN200 RESILIENT SEATED GATE VALVE, FL-FL WITH EXTN. SPINDLEDN200 DI PIPE FL-FLDN200 PUDDLE FLANGEDN200 FLOWMETER DN200 DI PIPE FL-FL, 1250 LONGDN200 DISMANTLING JOINTDN200 HYDRAULIC CONTROL VALVE, BERMAD 700 SERIES "Y PATTERN"

DN200 DI PIPE FL-FLDN200 PE STUB FLANGE AND S/S BACKING RINGDN200 x 90° DI BEND, FL-FLDN200 DI PIPE FL-FLDN100 SOC-SOC RESILIENT SEATED VALVE, COMPLETE WITH

1875

330

TERRAFIRMA COMPOSITE FIBREGLASS COVERSCLASS B, COMPLETE WITH H.D. GALV. FRAMESAND SUPPORT BEAMS ( REFER TO DR'G32-17221-S001 )

TO OUTFALL

TO IRRIGATION WELL INLET

DN200 PE PIPE, FALLTO IRRIGATION WET WELL

1 2

3

4

56

78

9

10

5

11

1

2

3

4

5

7

8

9

10

5

11

14

12

13

5

1

2

3

4

5

6

7

8

9

DN200 PE100, PN16 PIPE

DN100 SERIES 2 PVC PIPE WITH HEADWALLAND IPLEX PVC FLAP VALVE

CONCRETE SURROUND

PVC PIPE SHROUD, SUPPORTABOVE PIPE ( PIPE NOT TO BEUSED FOR SUPPORT )

CONCRETE SUPPORT BLOCK

NOTES:1. ALL DI FITTINGS TO BE PN162. ALL FLANGED VALVES TO BE PN163. ALL VALVES AND FITTINGS TO BE THERMAL BONDED

POLYMETRIC COATED, COLOUR "LILAC"

FALL

CAST-IN ELECTRICAL CONDUIT( REFER TO ELEC'T. ENGINEERSDRAWINGS FOR SIZE ) ENSURETHERE IS FALL IN CONDUIT BACKTO THIS CHAMBER

4. VALVE PIT DIMENSIONS ARE APPROXIMATE, CONTRACTORTO CHECK PIPE FITTING DIMENSIONS PRIOR TO CONSTRUCTINGPRECAST VALVE PIT.

PRECAST CONCRETE PIT, REFER TODR'G 32-17221-S001 FOR STRUCTURALDETAILS

6

FROM

STOR

AGE

DN225 PE x 45° BRANCH

LAGO

ONS

DN225 PE x 45° SWEPT BEND

400900

NOM.

MIN.

PVC PIPE SHROUD, VALVE BOX & CONCRETE SURROUND

ELECTRICAL TRAY ( REFER TOELECTRICAL ENGINEERS DRAWINGSFOR SIZE AND LOCATION )

DN100 x 45° PVC BEND

DN200 PE x 45° SWEPT BEND( CONFIRM ANGLE ON SITE )

720 1560 720

COLOUR "LILAC"

330

350

200

11 3

3

3

FLOW LIMITING VALVE ( TO BE SETDURING COMMISSIONING TO LIMITFLOW TO 10 L/S )

IL 128.700

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateDrawnRevisionNo A1Original Size

Title

Project

Client

Check

DesignerDrawn

Scale

Design

Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Level 2, 102 Cameron St, Launceston TAS 7250 AustraliaPO Box 1269 Launceston TAS 7250T 61 3 6332 5500 F 61 3 6332 5555E [email protected] W www.ghd.com

Plot Date: Cad File No:21 October 2014 - 11:16 AM G:\32\17221\CADD\Drawings\32-17221-C007.dwgPlotted by: Jim Rogers

(Project Director)Approved

JobManager

ProjectDirector

PRELIMINARY

32-17221-C007 A

J. ROGERS E. GRUBER

1 : 20

0 200 800 1000mm600400

SCALE 1:20 AT ORIGINAL SIZE TasWater

DETAIL6C003 20SCALE 1 :

Page 11: Appendix B – Pipeline and Outfall Design · water and environment taswater taswater locality plan n.t.s. drawing list design philosophy to replace the existing outfall arrangement

FROM FLOW CONTROL CHAMBERDN200 PE PIPE

DN200 PE100 x 90° BEND

EXISTING WET WELL

EXIST. OUTLET PIPETO IRRIGATOR

EXIST. STEEL COLUMN

1000

EXISTING CONCRETE SLAB

PLAN OF IRRIGATION WELLSCALE 1 : 20

A-

A-

THRUST BLOCK

EXISTING INTAKE PIPE FROM RIVERSIZE AND DEPTH TO BE CONFIRMED

SECTIONA- 20SCALE 1 :

WL 127.34 ( 6/3/13 )

IL 128.70

RL 129.88

EXISTING PUMP COLUMN

EXISTING WET WELL

EXISTING CONCRETE SLAB ( ARRANGEMENTSHOWN IS INDICATIVE ONLY )

EXIST. HORIZONTALBRACE

EXISTING STEEL PLATFORMCOLUMN

DN200 PE PIPE

150

SANDPAPER, ETCH PRIME ANDAPPLY SIKASWELL 'S" BEAD

SIKASWELL "S" BEAD ALL ROUND80mm MIN. FROM EDGE

CONCRETE PLUGENSURE SUFFICIENT CLEARANCEFOR PUMP REMOVAL / INSTALLATION( CONFIRM ON SITE )

50CEMENT STABILISED SANDBACKFILL

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateDrawnRevisionNo A1Original Size

Title

Project

Client

Check

DesignerDrawn

Scale

Design

Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Level 2, 102 Cameron St, Launceston TAS 7250 AustraliaPO Box 1269 Launceston TAS 7250T 61 3 6332 5500 F 61 3 6332 5555E [email protected] W www.ghd.com

Plot Date: Cad File No:21 October 2014 - 11:17 AM G:\32\17221\CADD\Drawings\32-17221-C008.dwgPlotted by: Jim Rogers

(Project Director)Approved

JobManager

ProjectDirector 32-17221-C008 A

J. ROGERS E. GRUBER

AS SHOWN

0 200 800 1000mm600400

SCALE 1:20 AT ORIGINAL SIZE TasWater

DETAIL7C003 20SCALE 1 :

Page 12: Appendix B – Pipeline and Outfall Design · water and environment taswater taswater locality plan n.t.s. drawing list design philosophy to replace the existing outfall arrangement

A-

A-

SECTIONA- 20SCALE 1 :

400 WIDE PLASTIC COATED STEP IRONSTO COMPLY WITH AS1657

3600

3400

2082

200 3200 200

200

50mm LAYERCRUSHER DUST

MIN. 50 THICK CONC. SCREED40 FALL TO DRAIN PIPE

TERRAFIRMA COMPOSITE FIBREGLASS COVERSCLASS B, COMPLETE WITH H.D. GALV. FRAMESAND SUPPORT BEAMS

2 N12 TRIMMER BARS EACH FACE( 1600 LONG ) COG AS REQUIREDAT CORNERS TYP.

N12 - 200 EW, EF IN SLABAND WALLS

PLANSCALE 1 : 20

NOTE: PIT DIMENSIONS ARE NOMINAL, REFER TONOTE 4, DR'G. 32-17221-C007

B-

B-

300TYP.

PROVIDE REBATE IN WALLS TO SUITTERRAFIRMA SUPPORT BEAMS

GALV. N12 ANCHORS, 250 CRS.DRILL AND EPOXY FIX, 150EMBEDMENT.

SIKASWELL S2 WATERSTOP100 COVER TO INSIDE

150

900 SQ. x 150 THICKINSITU CONCRETE PLUG

WALL PENETRATION DETAILSCALE 1 : 20

NOTE: WALL REINFORCEMENT NOT SHOWNFOR CLARITY.

SECTION ELEVATION

N12 - 200 EACH WAY50 COVER

2 N12 - 200 EW

200

GALV. N12 ANCHORS, 250 CRS.DRILL AND EPOXY FIX, 150EMBEDMENT.

NOTES

1. TERRAFIRMA COVERS AND SUPPORT BEAMS TO BE DESIGNED BYTHE MANUFACTURER AND INSTALLED TO THE MANUFACTURERSINSTRUCTIONS. FRAMES AND SUPPORT BEAMS TO BE H.D. GALVANISED.

2. COVERS ARE TO HAVE LOCKING MECHANISM, LOCKING TOOL TO BESUPPLIED TO TASWATER.

3. PROVIDE SHOP DRAWINGS OF THE COVERS AND PRECAST PITPRIOR TO CONSTRUCTION.

4. PRECAST CHAMBER TO BE FOUNDED INTO NATURAL SOIL WITH AMINIMUM ALLOWABLE BEARING CAPACITY OF 100 kPa( TO BE CONFIRMED ON SITE )

5. CONCRETE WORKS TO BE IN ACCORDANCE WITH AS36006. COVER TO REINFORCEMENT TO BE 40mm FOR PRECAST AND

60mm ELSEWHERE.7. PRECAST CONCRETE STRENGTH TO BE 32 MPa MIN. MASS

CONCRETE STRENGTH TO BE 20 MPa MIN.

400W x 200 THICK PLINTH2 N12 "U" BARS, DRILL ANDEPOXY FIX, 110 EMBEDMENTSCABBLE CONC. BASE PRIORTO POUR

20 x 20 CHAMFER

SIKASWELL S2 WATERSTOPCENTRAL TYP.

500 LAP

SECTIONB- 20SCALE 1 :

20 MPa MASS CONCRETE AROUNDPERIMETER OF CHAMBER, 300 THICKMINIMUM VOLUME TO BE 6.5 CUBICMETRES ( REQUIRED TO PREVENTBOUYANCY )

500 LAPTYP.

TYPICAL CORNER DETAILSCALE 1 : 20

( PLAN VIEW )

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateDrawnRevisionNo A1Original Size

Title

Project

Client

Check

DesignerDrawn

Scale

Design

Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Level 2, 102 Cameron St, Launceston TAS 7250 AustraliaPO Box 1269 Launceston TAS 7250T 61 3 6332 5500 F 61 3 6332 5555E [email protected] W www.ghd.com

Plot Date: Cad File No:21 October 2014 - 11:18 AM G:\32\17221\CADD\Drawings\32-17221-S001.dwgPlotted by: Jim Rogers

(Project Director)Approved

JobManager

ProjectDirector

PRELIMINARY

32-17221-S001 A

J. ROGERS D. IMMS

1 : 20

0 200 800 1000mm600400

SCALE 1:20 AT ORIGINAL SIZE TasWater

Page 13: Appendix B – Pipeline and Outfall Design · water and environment taswater taswater locality plan n.t.s. drawing list design philosophy to replace the existing outfall arrangement

NORTH WEST ELEVATION

EXISTING PLAN AT PLATFORM LEVEL

SOUTH WEST ELEVATIONNORTH EAST ELEVATION

PROPOSED PLAN AT PLATFORM LEVEL

REMOVE ALL EXISTING GRATING

1. INDICATES SPAN DIRECTION OF MESH

2. B1 65 x 65 x 5 EA, WELD TO EXISTING PFC SUPPORTS TYP.

155

900 MA

X.

EXTENT OF REPLACEMENT

REPLACE EXISTING HANDRAILNEW HANDRAIL TO BE MONOWILLSTYPE, COMPLYING WITH AS 1657

NOTES

SCALE 1 : 25

SCALE 1 : 25

SCALE 1 : 25

SCALE 1 : 25 SCALE 1 : 25

3. ALL DIMENSIONS TO BE CONFIRMED ON SITE PRIORTO FABRICATION.

4. ALL WELDS TO BE 6mm CFW ( SP )5. ALL STEELWORK TO COMPLY WITH AS 4100.

3100 A

PPRO

X.

B1

NO MESH IN THIS AREA EXIST

. SWI

TCHB

OARD

OVER

EXIST

. SWI

TCHB

OARD

OVER

= = =

3680 A

PPRO

X.

3800 APPROX.

REMOVE EXISTING50 x 50 X 3 EA

REMOVE EXISTING50 x 50 X 3 EA

B1

B1 B1 B1 B1

B1 B1 B1

EXPANDED METAL MESH ( WEBFORGEWM 50075, GALVANISED ) LAP ADJOININGSHEETS MIN. 1 MESH

EXISTING 200PFC, & EA. ABRASIVE BLASTTOP FLANGE TO CLASS SA2.5 TO AS 2312,APPLY PROTECTIVE PAINT COATINGPRIOR TO FITTING OF METAL MESH.

6. MINIMUM PROTECTIVE COATING FOLLOWING ABRASIVEBLAST TO CLASS SA2.5, TO BE ONE COAT OF DULUXDUREMAX GPE XP TO 125 MICRONS DFT AND ONE TOP COAT OF DULUX WEATHERMAX HBR TO 80 MICRONS DFTCOLOUR TO MATCH EXISTING.

A-

TYPICAL SUPPORT DETAILSCALE 1 : 5

SUPPORT

MIN. 25 BEARING

CLAMP WITH WEBFORGE CLIP SETC010MG AT 450 CRS.

SECTIONA- 10SCALE 1 :

EXISTING EA. REMAINS

EXIST. 50 x 50 x 3 EA.TO BE REMOVED

NEW MESH INFILL

B1B1

NEW PLATFORM MESH

This Drawing must not beused for Construction unlesssigned as Approved

Date

CheckDrafting

DateDrawnRevisionNo A1Original Size

Title

Project

Client

Check

DesignerDrawn

Scale

Design

Conditions of Use.This document may only be used byGHD's client (and any other person whoGHD has agreed can use this document)for the purpose for which it was preparedand must not be used by any otherperson or for any other purpose.

DO NOT SCALE

Note: * indicates signatures on original issue of drawing or last revision of drawing

Level 2, 102 Cameron St, Launceston TAS 7250 AustraliaPO Box 1269 Launceston TAS 7250T 61 3 6332 5500 F 61 3 6332 5555E [email protected] W www.ghd.com

Plot Date: Cad File No:21 October 2014 - 11:19 AM G:\32\17221\CADD\Drawings\32-17221-S002.dwgPlotted by: Jim Rogers

(Project Director)Approved

JobManager

ProjectDirector

PRELIMINARY

32-17221-S002 A

J. ROGERS K. WALKER

AS SHOWN

0 250 1000 1250mm750500

SCALE 1:25 AT ORIGINAL SIZE

0 100 400 500mm300200

SCALE 1:10 AT ORIGINAL SIZE

0

SCALE 1:5 AT ORIGINAL SIZE

10050 200 250mm150

Page 14: Appendix B – Pipeline and Outfall Design · water and environment taswater taswater locality plan n.t.s. drawing list design philosophy to replace the existing outfall arrangement

W

W

Drawing No.

Plotted Designed

Checked Scale @ A3

Drawn

Issue

Sheet Title

Project

Client

By

REVISIONS

DescriptionDate Issue

Page 15: Appendix B – Pipeline and Outfall Design · water and environment taswater taswater locality plan n.t.s. drawing list design philosophy to replace the existing outfall arrangement

S S

S

S

S

SS

S

S

S

S

W

W

W

W

Drawing No.

Plotted Designed

Checked Scale @ A3

Drawn

Issue

Sheet Title

Project

Client

By

REVISIONS

DescriptionDate Issue

Page 16: Appendix B – Pipeline and Outfall Design · water and environment taswater taswater locality plan n.t.s. drawing list design philosophy to replace the existing outfall arrangement

Drawing No.

Plotted Designed

Checked Scale @ A3

Drawn

Issue

Sheet Title

Project

Client

By

REVISIONS

DescriptionDate Issue

Page 17: Appendix B – Pipeline and Outfall Design · water and environment taswater taswater locality plan n.t.s. drawing list design philosophy to replace the existing outfall arrangement

Drawing No.

Plotted Designed

Checked Scale @ A3

Drawn

Issue

Sheet Title

Project

Client

By

REVISIONS

DescriptionDate Issue

Page 18: Appendix B – Pipeline and Outfall Design · water and environment taswater taswater locality plan n.t.s. drawing list design philosophy to replace the existing outfall arrangement

D.M. A.S, P & P. The current version can be downloaded from:It is the users responsibility to ensure this drawing is the current version.

was intended. Reproduction of this drawing or its content in anyof TasWater, and may only be used for the purpose of which it

format other than printed hard copies is strictly prohibited.

This drawing and the information it contains is, and remains the property

C

Drawn

Checked

SCALES: AS SHOWN(All scales are correct at A3)

DWG No.ISSUE DATE: SHEET No.

www.taswater.com.au.dwgXRef File:36-42 Charles Street, Launceston Tasmania 7250

T: 03 13Mywater (13 6992) F: 03 6336 2567 PO Box 745

Manager Asset Management

2014

TasWaterSam Van Brecht

G-100

TRENCH REINSTATEMENTSFLEXIBLE PAVEMENTS

BLW G-100Dec. 2009