Appendix A
Feasibility Level Design, 30,000 TPD Tailings Storage Facility
And
Tailings Distribution and Water Reclaim Systems
Copper Flat Project
Sierra County, New Mexico
Golder Associates Inc.,
Revised, June 2016
Revised June 2016 iv 1531453
p:\abq projects\2015 projects\1531453 themac dp permit support\work product\fs report 2015\final\1531453_themac_30000 tpd fs_rpt_20160527rev.docx
Drawing 21 Cyclone Plant Area General Arrangement Plan Drawing 22 Surge Pond Plan Cross-Section and Details Drawing 23 General Process Flow Diagram Drawing 24 Tailing Delivery and Distribution Piping Plan Drawing 25 Tailing Distribution Plan and Profile (1 of 2) Drawing 26 Tailing Distribution Plan and Profile (2 of 2) Drawing 27 Water Reclaim System Piping Plan Drawing 28 Water Reclaim System Details Drawing 29 Secondary Containment Details and Sections
List of Appendices
Appendix A Site Exploration Appendix A.1 Test Pit Logs Appendix A.2 Drill Hole Logs Appendix A.3 Geotechnical Test Results
Appendix A.3.1 Gradation Moisture/Density Test Reports Appendix A.3.2 Triaxial Test Reports Appendix A.3.3 Permeability Test Reports Appendix A.3.4 Consolidation Test Reports
Appendix B Tailings Test Results Appendix B.1 Cyclone Test Results, Full Scale Cyclone Performance Simulation Appendix B.2 Tailings Gradations Appendix B.3 Cyclone Underflow Test Results Appendix B.4 Cyclone Overflow and Whole Tailings Test Results
Appendix B.4.1 Cyclone Overflow Test Reports Appendix B.4.2 Whole Tailings Test Reports
Appendix C FSconsol Model Output Appendix D Underdrain Design Calculations
Appendix D.1 Drain Pipe Spacing Calculations Appendix D.2 Drain Pipe Deflection Calculations
Appendix E TSF Underdrain Collection Pond Inflow Estimation Appendix F Hydrologic Calculations
Appendix F.1 Impoundment Diversion Ditch Calculations Appendix F.2 Dam and TSF Underdrain Collection Pond Area Hydrologic Calculations
Appendix G Water Balance Calculations Appendix H Stability Analysis Supporting Data and Computer Output
Appendix H.1 Maximum Embankment Section Appendix H.2 Stability Section B-B’ Appendix H.3 Stability Section D-D’
Appendix I Foundation Settlement Potential Evaluation Appendix I.1 Settlement Potential, Copper Flat Tailings Embankment Foundation Appendix I.2 Settlement & Geomembrane Strain Analysis
Appendix J Drawings
Revised June 2016 33 1531453
p:\abq projects\2015 projects\1531453 themac dp permit support\work product\fs report 2015\final\1531453_themac_30000 tpd fs_rpt_20160527rev.docx
7.0 TAILINGS DELIVERY AND DISTRIBUTION SYSTEM DESIGN
7.1 General System Description
The tailings delivery and distribution system design consists of pipeline system that delivers whole tailings
from the processing plant to the tailings storage facility. Whole tailings will be separated into fine material
and sand material in the cyclone plant. The sand fraction will be transported to the TSF and used for dam
construction while fine material will be deposited into the TSF. The tailings surge system is designed for
tailings management in case of unanticipated shutdown of any of the tailings stations or surges or overflows
from station sumps. Return or reclaim water will be collected from the TSF surface pond and TSF
underdrain water collection pond and transported back to the process plant. A general process flow diagram
for the tailing delivery and distribution system is provided on Drawing 23.
Process equipment for the tailings delivery and distribution system will be located in four main stations as
listed below:
Cyclone Station: including the cyclone cluster, slurry pumps, slurry transfer sumps, gland seal water system, and electrical equipment;
Surge Discharge System: including the surge pond evacuation pumps and lined secondary containment ditches;
TSF Return Water Pond Barge Station: including a floating barge and barge mounted vertical turbine pumps and electrical equipment; and
TSF Underdrain Collection Pond Pump Station: including vertical turbine pumps in a permanent structure and electrical equipment.
Tailings distribution will include whole tailings transport from the process area to the cyclone station and
sand and fine tailings transport to the TSF. Return water will include tailing drainage water and TSF return
water transported to the process plant. The major pipelines are listed below, and their interactions are
shown in the overall system process flow diagram on Drawing 23.
Cyclone Feed Line
Cyclone Overflow Line
Cyclone Underflow Line
Cyclone Whole Tailings Bypass Line
TSF Return Water Line
TSF Underdrain Collection Return Water Line
Main Surge Discharge Line
The major pipelines will be installed within secondary containment ditches lined with a minimum 60-mil
HDPE geomembrane liner placed over six inches of liner bedding fill. The secondary containment ditches
and associated pipelines will be constructed in accordance with the requirements listed in 20.6.7.23
Revised June 2016 36 1531453
p:\abq projects\2015 projects\1531453 themac dp permit support\work product\fs report 2015\final\1531453_themac_30000 tpd fs_rpt_20160527rev.docx
and consolidation can occur under managed deposition is primarily a function of rate of tailings rise. It is
also influenced by tailings properties, climatic conditions, surface water management, and operator effort.
7.4 Management of Upset Flows
Potential upset flows from the process area, cyclone plant, and TSF will be controlled through a series of
secondary containment ditches, the surge pond, and the TSF underdrain collection pond (see Section 6.5).
The secondary containment ditches and associated pipelines will be constructed in accordance with the
requirements listed in 20.6.7.23 NMAC. The secondary containment ditches will run from the process area
to the TSF (the main ditch), from the main ditch to the cyclone area, and from the cyclone area to the surge
pond. The secondary containment ditches are designed to contain and transport flows via gravity that are
related to potential upset conditions and direct precipitation onto the ditches associated with the 25-year
24-hour storm event (2.88 inches). Maximum upset flow conditions would be associated with overtopping
of the process water reservoir (as estimated by M3, the design contractor for the process water reservoir).
This maximum upset flow was assumed to be 18,000 gpm over a 30-minute period, at which point the
process area pumps would be shut down. The secondary containment ditches are designed for these
maximum upset flows, direct precipitation, and an additional 2 feet of freeboard. The main ditch is designed
to flow to the TSF by gravity for the first six years. After year six, gravity flow to the TSF is no longer possible
because of the increased height of the TSF and upset flows will then discharge to the surge pond via gravity
in a lined ditch through year 11.1. The alignment of the secondary containment ditches is shown on
Drawings 2, 3, 10, 11, 12, 21, and 24 through 26. Details of the secondary containment ditches are provided
in Drawing 29.
Surge pond cross sections and details are shown on Drawing 22. The surge pond liner system will consist
of a liner bedding fill layer overlain with a minimum 60-mil HDPE geomembrane liner. The surge pond is
located at an elevation of 5,340 feet and is sized for a surge retention time of half an hour with and additional
reserve capacity of over one million gallons. The pond is sized for the retention of approximately 1,610,000
gallons of slurry with an additional 2 feet of freeboard. The use of the surge pond will be intermittent and
temporary and the pond will be empty under normal operating conditions. The pond will be equipped with
dedicated hard-wired pumps that will automatically evacuate its contents. Emergency power for the pumps
will be provided by the emergency diesel power generation system located on-site in the event of a power
outage. The process facility control room will be equipped with emergency alarms that notify the operator
of an upset condition allowing the operator to make necessary adjustments in the process, as needed. The
pumps at the surge pond will be automatically activated upon the pond reaching a predetermined level.
Water and solids collected from the surge pond will be discharged through a 12-inch HDPE DR17 pipeline
to the top of the TSF. The solids handling pump is designed to evacuate the surge pond within 12 hours.
Revised June 2016 47 1531453
p:\abq projects\2015 projects\1531453 themac dp permit support\work product\fs report 2015\final\1531453_themac_30000 tpd fs_rpt_20160527rev.docx
11.0 TAILINGS DAM FOUNDATION SETTLEMENT POTENTIAL
11.1 Analysis Approach
The TSF will consist of an earthen starter dam constructed to a height of approximately 50 feet with the
remainder of the dam constructed with sand recovered from the cyclone plant. A geotechnical investigation
was performed in the embankment footprint, which included standard penetration testing and sample
collection from the surface to a depth of 50 feet. Drilling indicated that in general, the tailings embankment
foundation consists primarily of alluvial deposits that include silt, sand and gravel, which are underlain by
clay.
Representative samples of the foundation strata were analyzed in Golder’s geotechnical laboratory for
index properties, gradation, and Atterberg limits. Selected samples were remolded in the laboratory, and
the remolded samples were subjected to one-dimensional consolidation testing.
Settlement calculations were developed for the post-construction embankment, which represents the worst-
case condition. Staged settlement was not analyzed because settlement of the embankment will be
adequately mitigated by continuous fill placement during ongoing embankment construction. Settlement
calculations were performed using the computer model SETTLE3D v. 2.0, a computer program developed
by Rocscience, Inc., for the analysis of settlement and consolidation under foundations and embankments.
A detailed description of the settlement potential investigation, settlement calculations and supporting
information are contained in Appendix I.1. Drill holes and the location of cross-sections used to evaluate
subsurface conditions are shown on Drawing 3. Drawings 5 and 7 present geologic cross sections B-B’ and
D-D’, respectively, which were developed to evaluate settlement perpendicular to the dam axis. The cross-
sections also include information derived from the former geotechnical study conducted on behalf of
Quintana by Sergent Hauskins and Beckwith (SHB, 1980). Drill hole logs are contained in Appendix A.2.
A differential settlement and geomembrane strain analysis was subsequently conducted by Golder and is
included in Appendix I.2. Cross sections were developed to intercept the various geologic materials
underlying the TSF site. The engineering properties of the foundation materials were derived from the 1980
Sargent, Hauskins and Beckwith (SHB) geotechnical study, the geotechnical investigation conducted as
part of the TSF design report and experience with similar foundation materials.
11.2 Settlement Potential Analysis Results
Laboratory consolidation testing was conducted on remolded specimens of the fine fraction of samples
recovered from the embankment foundation. As such, the settlement prediction does not account for the
presence of the coarse fraction in the foundation soils, and associated inter-particle contact and support of
Revised June 2016 48 1531453
embankment moist unit weight of 130 pcf. Tailings testing completed after the settlement potential study
p:\abq projects\2015 projects\1531453 themac dp permit support\work product\fs report 2015\final\1531453_themac_30000 tpd fs_rpt_20160527rev.docx
foundation loads. Settlement predictions based on the laboratory consolidation tests are therefore
conservative.
Results of the settlement potential analysis are shown graphically on geologic sections B-B’ and D-D’. The
maximum calculated settlement beneath the embankment is approximately 2.1 feet in the area of the
maximum dam (and tailings beach) foundation loads. Settlement decreases at a relatively uniform rate as
the weight of post-construction loading decreases towards the outer toe of the embankment.
Settlement prediction based on the laboratory consolidation testing of the fine fraction of foundation
samples is conservative. SPT testing conducted during drilling showed the foundation strata to generally
be very dense to hard. On the basis of SPT test results, actual post-construction consolidation settlement
of less than 1 foot is anticipated.
Dam construction will be more or less continuous during the life of the facility. The effects of foundation
settlement include the potential for the loss of dry freeboard for stormwater storage. The potential loss of
freeboard can be mitigated by elevating the dam crest with managed/targeted placement of cyclone
underflow sand.
The analyses did not indicate the potential for differential settlement that could impact the integrity of the
TSF geomembrane liner. Sections B-B’ and D-D’ indicate predicted settlement varies uniformly across
areas subject to changing foundation loads.
The impoundment underdrain will pass beneath the dam in a steel pipe placed in a ditch backfilled with
concrete near section F-F’ (Drawing 9). The settlement will not adversely impact the impoundment
underdrain outlet pipe. There is adequate grade and elevation change along the outlet pipe alignment to
accommodate predicted settlement.
A basalt outcrop identified by SHB (SHB, 1980) may lie beneath or in the vicinity of the impoundment
underdrain pipe inlet near the upstream toe of the dam. The outcrop occurred in an area that was disturbed
during Quintana dam construction activities, and was not observed during the recent site exploration. If the
inlet to the underdrain pipe bears on basalt, local differential settlement could occur along the pipe
alignment, which could induce stress on the outlet pipe. If, during construction, a basalt outcrop is identified
at the location of the inlet, an alignment change may be warranted to avoid the pipe bearing on basalt.
It should be noted that the settlement potential investigation was performed for a previously completed
design study, and evaluated an embankment geometry that differs from that presented in this report. The
new embankment is higher and the depth of embankment fill overlying the foundation is greater for this
30,000 tons per day design; however, the original analyses assumed a higher, more conservative
Revised June 2016 49 1531453
p:\abq projects\2015 projects\1531453 themac dp permit support\work product\fs report 2015\final\1531453_themac_30000 tpd fs_rpt_20160527rev.docx
was conducted indicates a post embankment fill placement moist unit weight of approximately 113 pcf. The
foundation loads imposed by the higher embankment fill, when corrected for the moist unit weight
determined by laboratory testing, are lower than those used in the settlement potential analysis. Therefore,
the results of the settlement investigation presented above are conservative relative to the current design.
As part of future detailed engineering studies, settlement calculations will be updated for final design
conditions; however, the conclusions are anticipated to be consistent with those presented herein.
The results of the differential settlement and geomembrane strain analysis indicates that, in general,
settlement potential across the TSF is predicted to be limited. As such, the potential for tearing of the HDPE
liner due to potential differential settlement within the entire area of the TSF is considered to be low. The
maximum settlement is estimated to be 0.72 feet, while the maximum tensile strain on the HDPE liner due
to differential settlement is estimated to be 0.02 percent. The allowable tensile strain on an 80 mil HDPE
geomembrane liner is 10 percent and the predicted tensile strain is well within acceptable conditions.
Therefore, Golder does not expect tearing of the HDPE liner due to differential settlement to be an issue.
APPENDIX I.1 SETTLEMENT POTENTIAL, COPPER FLAT TAILINGS EMBANKMENT FOUNDATION
APPENDIX I.2 SETTLEMENT & GEOMEMBRANE STRAIN ANALYSIS
Page 1 of 7
1.0 OBJECTIVE
2.0 METHODOLOGY
2.1 Settlement Analysis
Unit WeightPoisson's
RatioEffective Modulus
(lb/ft3) (-) (lb/ft2)0 97 0.49 10,000,000
1 110 0.30 4,000,000
2 110 0.30 4,000,000
3 130 0.30 5,000,000
4 160 0.30 100,000,000
5 104 0.30 790,600
6 106 0.30 671,400
7 125 0.30 100,000,000
8 175 0.30 100,000,000
SETTLEMENT & GEOMEMBRANE STRAIN ANALYSIS
Estimate the tensile strain caused by differential settlement of the in-situ subsurface materials inferred below the proposed Copper Flat tailing facility.
The proposed geomembrane liner system may experience tensile strain because of differential settlement caused from the loading (tailings and embankment) of the subsurface soils.
Settlement was calculated using the finite element software SigmaW from the 2012 GeoStudio package. Cross sections A and B (both shown in plan view on Figure 1 and in profile view in Figure 2) showing the proposed tailing facility and tailings embankment layout/dimensions, inferred subsurface soils and boundaries were imported into the software for analyses. Geotechnical properties for each subsurface material layer were selected from previous reports (Refs. 1 and 2) and from experience with similar soils. The geotechnical properties were incorporated into the software and used for the settlement analyses. Table 1 below provides a list of the geotechnical subsurface material layers and properties.
Bedrock
Material No. Material Name
Geotechnical Properties
Table 1: Geotechnical Subsurface Material Layers and Properties
Tailings/Embankment
Well-Graded Gravel
Well-Graded Sand with Silt and Gravel
Conglomerate
Basalt
Lean Clay, Fat Clay, Silty Clay
Silt
Caliche
Made By: JLChecked by: GMReviewed by: MP
Feasibility Study Copper Flat ProjectVolume 1 - Tailings Storage Facility
Golder Differential Settlement AnalysisJune 2016
Page 2 of 7
Feasibility Study Copper Flat ProjectVolume 1 - Tailings Storage Facility
Golder Differential Settlement Analysis
2.1 Tensile Strain from Differential Settlement
Where: e = Tensile strain in liner system between Points A and B
L1 = Distance between Points A and B, pre-settlement
L2 = Distance between Points A and B, post-settlement
s = Horizontal distance between Points A and B
3.0 CALCULATIONS AND RESULTS
3.1 Tensile Strain from Differential Settlement
The tensile strain of a base liner system caused by differential settlement can be estimated by the following equation:
The settlement results for Cross Section A and Cross Section B are illustrated below. Points for liner strain evaluation were selected at locations where peaks or valleys were observed in the results. The liner strain evaluations due to differential settlement of the subsurface materials are summarized in Table 2 and Table 3.
Settlement results from the SigmaW runs were used to calculate the induced strain in the geomembrane liner system along Cross Section A and B shown in Figure 1 and Figure 2.
Illustration: Liner Differential Settlement
Point A
Point BL1
L2
Pre-settlement
Post-settlement
horizontal distance = s
𝜀𝜀 =𝐿𝐿2 − 𝐿𝐿1𝐿𝐿1
𝐿𝐿 = 𝐸𝐸𝐸𝐸𝐸𝐸𝐸𝐸.𝐴𝐴 − 𝐸𝐸𝐸𝐸𝐸𝐸𝐸𝐸.𝐵𝐵 2 + 𝑠𝑠2
June 2016
Page 3 of 7
Feasibility Study Copper Flat ProjectVolume 1 - Tailings Storage Facility
Golder Differential Settlement Analysis
Illustration: Settlement Profile - Cross Section A(refer to Figure 2 for location along horizontal distance)
A
B
C D
E
F
G H
I
J
K
L
M
N
-0.8
-0.7
-0.6
-0.5
-0.4
-0.3
-0.2
-0.1
0
0.1
0.2
0.3
0.4
0.5
0.60 1000 2000 3000 4000 5000 6000 7000 8000
Sett
lem
ent (
ft)
Horizontal Distance (ft)
Tailings Embankment Cross Section A(NOT TO SCALE)
June 2016
Page 4 of 7
Feasibility Study Copper Flat ProjectVolume 1 - Tailings Storage Facility
Golder Differential Settlement Analysis
Pre-settlement,
feet
Post-settlement,
feet
A 5383.4 5383.4 0.00B 5311.7 5311.0 0.72B 5311.7 5311.0 0.72C 5275.5 5275.1 0.40D 5267.5 5267.1 0.40E 5251.8 5251.3 0.53E 5251.8 5251.3 0.53F 5230.0 5229.6 0.45F 5230.0 5229.6 0.45G 5230.2 5229.9 0.30H 5239.6 5239.3 0.29I 5197.3 5197.1 0.20I 5197.3 5197.1 0.20J 5185.2 5185.1 0.11J 5185.2 5185.1 0.11K 5180.4 5180.1 0.34K 5180.4 5180.1 0.34L 5176.7 5176.5 0.22L 5176.7 5176.5 0.22M 5173.3 5173.0 0.29M 5173.3 5173.0 0.29N 5168.5 5168.5 0.00
350.00 350.352 350.358 0.0017%
150.00 155.850 155.826 Under Compression
700.00 700.339 700.337 Under Compression
200.00 200.000 200.000 0.0001%
Tensile Strain
525.019520.00 524.920 0.0188%
580.00 581.129 581.109
Points
Elevations
Horizontal Distance (s),
feetPre-settlement Dist. (L1), feet
Post-settlement
Dist. (L2), feet
Under Compression
Table 2: Liner Integrity Analysis Results - Cross Section A
650.00 650.113 650.111 Under Compression
125.00 125.046 125.048 0.0015%
113.00 113.102 113.090 Under Compression
250.00 250.046 250.051 0.0018%
225.00 225.030 225.028 Under Compression
Settlement, feet
Maximum Tensile Strain due to Differential Settlement = 0.0188%
June 2016
Page 5 of 7
Feasibility Study Copper Flat ProjectVolume 1 - Tailings Storage Facility
Golder Differential Settlement Analysis
Illustration: Settlement Profile - Cross Section B(refer to Figure 2 for location along horizontal distance)
A
B
C
D E
F
GH
I
J
-1.2
-1.1
-1
-0.9
-0.8
-0.7
-0.6
-0.5
-0.4
-0.3
-0.2
-0.1
0
0.1
0.2
0.3
0.4
0.5
0.60 1000 2000 3000 4000 5000
Sett
lem
ent (
ft)
Horizontal Distance (ft)
Tailings Embankment Cross Section B(NOT TO SCALE)
June 2016
Page 6 of 7
Feasibility Study Copper Flat ProjectVolume 1 - Tailings Storage Facility
Golder Differential Settlement Analysis
Pre-settlement,
feet
Post-settlement,
feet
A 5280.2 5280.2 0.00
B 5226.4 5226.0 0.43
C 5213.7 5213.4 0.34
D 5229.7 5229.3 0.37
E 5239.3 5239.0 0.35
F 5211.6 5211.3 0.29
F 52116.0 52115.7 0.29
G 5196.2 5195.2 0.96
G 5196.2 5195.2 0.96
H 5197.3 5196.4 0.89
H 5197.3 5196.4 0.89
I 5198.6 5197.4 1.16
I 5198.6 5197.4 1.16
J 5199.3 5199.3 0.00
4.0 DISCUSSION AND CONCLUSIONS
It is understood that the liner system will consist of HDPE 80 mil geomembrane liner between a liner bedding fill layer and tailings. The minimum allowable tensile strain for geomembrane is 10% (Refs. 3). Based on the analysis performed herein and available information at the time of this calculation, the estimated tensile strain along Cross Section A and Cross Section B are less then the allowable tensile strain. The allowable strain is presented in Table 4.
Cross SectionMax. Tensile Strain from Differential Settlement Liner Component Allowable Tensile Strain
Tensile Strain less than
Allowable?
Table 4: Summary of Allowable Liner Strains
The potential strain of the geomembrane liner system was analyzed for overall differential settlement along two cross sections (Cross Section A and B) within the proposed Copper Flat tailing facility. Based on the available information, experience with similar subsurface materials and conservative assumptions, the maximum liner strain is estimated to be 0.02%, from differential settlement which is less than the allowable strain for geomembrane liners.
Yes
Yes
847.00 848.707 848.734 0.0032%
30.00 34.000 33.986 Under Compression
79.00 83.716 83.696 Under Compression
530.000 530.003 0.0005%
46922.440 0.0014%
160.00 160.004 160.004 0.0003%
195.00 195.004 195.003 Under Compression
46921.770430.00
A 0.0188%Geomembrane 10%
B 0.0032%
Points
Elevations
Horizontal Distance (s),
feetPre-settlement Dist. (L1), feet
Post-settlement
Dist. (L2), feet Tensile Strain
Table 3: Liner Integrity Analysis Results - Cross Section B
Settlement, feet
Maximum Tensile Strain due to Differential Settlement = 0.0032%
530.00
June 2016
Page 7 of 7
Feasibility Study Copper Flat ProjectVolume 1 - Tailings Storage Facility
Golder Differential Settlement Analysis
5.0 REFERENCES1. -
2. -
3. -
GeoStudio File Names DescriptionFull Cross Section A.gsz Cross Section A Settlement Analysis
Full Cross Section B.gsz Cross Section B Settlement Analysis
AttachmentsFigure 1: Cross Section Location Plan
Figure 2: Geologic Cross Sections
Golder 2013, Feasibility Study Copper Flat Project, Sierra County, New Mexico, Volume 1 - Tailings Storage Facility, report dated July 2013, Golder Project No. 103-92557.011
SHB (Sergent, Hauskins and Beckwith), 1980. Tailings Dam and Disposal Area - Quintana MineralsCorporation - Copper Flats Project - Golddust, New Mexico. October 14, 1980
Robert M. Koerner (2005) Designing with Geosynthetics, Fifth Edition, Pearson/Prentice Hall.
June 2016
A
2
B
2
PROPOSED ULTIMATE TAILINGS
STORAGE FACILITY FOOTPRINT
N 11974000 N 11974000
E 8
74
00
0E
8
74
00
0
N 11976000 N 11976000
N 11978000 N 11978000
N 11972000 N 11972000
N 11970000 N 11970000
E 8
76
00
0E
8
76
00
0
E 8
72
00
0E
8
72
00
0
E 8
70
00
0E
8
70
00
0
5
2
0
0
5
2
0
0
5
3
0
0
5
3
0
0
5
4
0
0
5
4
0
0
5400
5
4
0
0
5500
5
5
0
0
5
2
0
0
5300
BH-1
BH-2
BH-3
BH-4
BH-5
BH-9
BH-10
BH-11
BH-15
BH-16
BH-17
BH-21
BH-22
BH-24
BH-25
BH-28
BH-6
BH-7
BH-8
BH-12
BH-13
BH-14
BH-18
BH-19
BH-20
BH-23
BH-26
BH-27
TP-2
TP-3
TP-4
TP-5
TP-7
TP-8
TP-9
TP-11
TP-16
TP-21
TP-22
TP-23
TP-26
TP-27
TP-28
TP-29
TP-30
TP-1
TP-10
TP-12
TP-13
TP-14
TP-15
TP-17
TP-18
TP-19
TP-20
TP-24
TP-25
TP-31
TP-32
01 in
1531453
CONTROL
0001
FIGURE
1
A
2016-05-11
JHR
JS
JL
GM
COPPER FLAT
SIERRA COUNTY, NEW MEXICO
CROSS-SECTION LOCATION PLAN
TITLE
PROJECT NO. REV.
PROJECT
CLIENT
IF
T
HIS
M
EA
SU
RE
ME
NT
D
OE
S N
OT
M
AT
CH
W
HA
T IS
S
HO
WN
, T
HE
S
HE
ET
S
IZ
E H
AS
B
EE
N M
OD
IF
IE
D F
RO
M: A
NS
I B
CONSULTANT
PREPARED
DESIGNED
REVIEWED
APPROVED
YYYY-MM-DD
Path: \\tucson\cadd\C
HE
VR
ON
\Q
UE
ST
A\99_P
RO
JE
CT
S\1653370_Q
trD
am
Isnp\0002_E
AP
\02_P
RO
DU
CT
IO
N\D
WG
\ | F
ile N
am
e: 1531453_0001_F
IG
_001.dw
g
0
FEET
250 500
1'' = 500'
LEGEND
EXISTING GROUND CONTOUR (ft -MSL)
CROSS-SECTION CALLOUT
SECTION ID
DRAWING SHEET LOCATION
3600
A
2
HOLLOW STEM AUGER (HSA) BOREHOLE
TEST PIT
BH-11
TP-8
June 2016
ELEV
ATIO
N (F
T)
ELEV
ATIO
N (F
T)
50505100515052005250530053505400545055005550
50505100515052005250530053505400545055005550
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 6000 6200 6400 6600 6800 7000 7200 74007481
ULTIMATE IMPOUNDMENT SURFACE
EXISTING GROUNDPHASE 1
PHASE 2PHASE 3
PHASE 4
EXISTING EMBANKMENTTAILINGS
ELEV
ATIO
N (F
T)
ELEV
ATIO
N (F
T)
5050510051505200525053005350540054505500
5050510051505200525053005350540054505500
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 5896
ULTIMATE IMPOUNDMENT SURFACE
EXISTING GROUNDPHASE 1PHASE 2
PHASE 3PHASE 4
EXISTING EMBANKMENT AND DIVIDER BERM
01
in
1531453CONTROL0001
FIGURE
2A
2016-05-11
JHR
JS
JL
GM
COPPER FLAT
SIERRA COUNTY, NEW MEXICO
GEOLOGIC CROSS-SECTIONS TITLE
PROJECT NO. REV.
PROJECT
CLIENT
IF T
HIS
MEA
SUR
EMEN
T D
OES
NO
T M
ATC
H W
HAT
IS S
HO
WN
, TH
E SH
EET
SIZE
HAS
BEE
N M
OD
IFIE
D F
RO
M: A
NSI
B
CONSULTANT
PREPARED
DESIGNED
REVIEWED
APPROVED
YYYY-MM-DD
Path
: \\tu
cson
\cad
d\TH
EMAC
\Cop
perF
lat\9
9_PR
OJE
CTS
\153
1453
_NM
Cop
perC
orpS
uppo
rt\00
01_S
ectio
ns\0
2_PR
OD
UC
TIO
N\D
WG
\ |
File
Nam
e: 1
5314
53_0
001_
FIG
_002
.dw
g
A2
SCALE 1'' = 500' CROSS-SECTION A
B2
SCALE 1'' = 500' CROSS-SECTION B
0
FEET
250 500
1'' = 500'
WELL-GRADED GRAVEL
BASALT
WELL-GRADED SAND WITH SILT AND GRAVEL
CONGLOMERATE
SILT
CALICHE
LEAN CLAY, FAT CLAY, SILTY CLAY
BEDROCK
LEGEND
June 2016