Uma solução para infusão de fluidos até 50% mais rápida

Cateter Venoso Central

“High-flow” Edwards

Para momentos em que a infusão rápida de fluidos é importante, a Edwards Lifesciences disponibiliza o cateter venoso central “high-flow”:

Outros Cateter Venoso Central

Desenho do Backform: Facilita o fluxo de fluidos pelo cateter

O cateter venoso central “high-flow” Edwards Multi-Med infunde fluidos até 50%mais rápido que outros catéteres venosos centrais. As características de alto fluxo são resultantes da otimização tanto do cateter quanto do backform.

O backform especial de alto fluxo permite um significante incremento da infusão rápida de fluidos, comparada a catéteres padrão.

Cobertura AMC THROMBOSHIELD:Combinação de cloreto de benzalcônioe heparina

Reduz o risco de infecções associadas aocateter;

Proporciona proteção antimicrobiana na su-perfície interna e externa do cateter;

Reduz a colonização microbiana e a formaçãode trombos.

Conheça os benefícios do cat

Cateter Venoso Central

Principais características:

Lúmens das extensõestransparentes para visualizar

a infusão de fluidos

Conexões InterLink ajudam aeliminar o risco de acidentes

com agulhas

A ponta “soft” reduzo risco de traumavascular

O “Backform” otimizaa infusão do fluxo pelo

cateter

▲▲

Codificadopor cores,facilitando aidentificaçãode cadalúmen

Fio-guia com desenho inovador

Uso com uma única mão. Procedimentoprático e rápido;

Fácil manuseio. Atençãofocada apenas ao procedi-mento;

Fio-guia com marcaçõesem centímetros ajudam adeterminar a profundidade dainserção.

Acesso sem agulhas

O cateter venoso central “high-flow” EdwardsMulti-Med pode trazer conexões de injeçãoInterLink, que ajudam a eliminar o risco deacidente com agulhas.3

Poliuretano de fácil manuseio

Material de poliuretano contribui para o ex-celente manuseio, flexibilidade e resistênciaà dobra;

Ponta soft reduz o riscode trauma vascular;4

Lúmens de extensão trans-parentes para visualização dainfusão do fluido;

Conectores codificados por cores e com infor-mações impressas para facilitar.

teter venoso central

Edwards Vantex

Liberação de íonsde prata e platinaao interagir com

o sangue

“Proteção Antimicrobiana”Corte transversal mostrando

a liberação ativa dos íonsde prata em todas assuperfícies do cateter.

Um revolucionário material antimicrobiano5

O Vantex CVC é o único cateter venoso cen-tral em poliuretano com elementos naturaisde prata, carbono e platina;

O antimicrobiano Oligon libera íons de pratana superfície do cateter, evitando a formaçãode colônias bacterianas;

Elimina a possibilidade de complicações asso-ciadas a clorexidina;

Reduz gastos e tempo clínico no tratamentoao diminuir o risco de colonização bacteriana,permitindo uma maior permanência docatéter no paciente.

▲▲

▲▲

▲▲

▲▲

▲▲

▲▲

“High-flow” Edwards Multi-Med Cateter Venoso Central

“High-flow” Edwards Multi-Med Cateter Venoso Central

Referências:

1. Hasleu T M, et al. J Clin Microbiology. 1982; 26(4):696-701.2. Dados de arquivo, Divisão Edwards Critical-Care.3. Skolnick R, et al. Evaluation and Implementation of a Needleless Intravenous System: Making

Needlesticks a Needless Problem. AJIC. Feb 1993: 21, 39-41.4. Gravenstein N, Blackshear RH. In Vitro. Evaluation of Relative Performance of Central Venous

Catheters: Comparison of Materials, Selected Models, Number of Lumens, and Angles of Inci-dence to Simulate Membrane. J Clin Monit. 7:1-6:1991.

5. Data on file. Edwards Lifesciences LLC.Pearson ML. Guideline for prevention of intravascular device-related infections. PartI.Intravascular device-related infections: an overview. The Hospital Infection Control PracticesAdvisory Commitee. Am J Infect Control. 1996;24(4):262-277.Torricelli R, Wuthrich B.Life-threatening anaphylactic shock due to skin application of chlorhexi-dine. Clin Exp Allergy. 1996;26(1):112.Gabler WL, Roberts D, Harold W. The effect of chlorhexidine on blood cells. J.Periodontal Res.1987;22(2):150-155.Butler WH, Iswaran TJ. Chlorhexidine: Safety Evaluation. Royal Society of Medicine,International Congress and Symposium, Series Number 23.

Cateter Venoso Central nas opçõesduplo ou triplo lúmen

✓ 1 cateter radiopaco recoberto com AMCTHROMBOSHIELD (revestimento antimicrobianode heparina) e clamps removíveis

✓ 1 seringa de 5 mL

✓ 1 cateter sobre agulha 18 GA x 2 1/2” (6,35 cm)

✓ 1 fio-guia reto com marcação em centímetros,ponta reta e em “J”

✓ 1 dilatador de vaso

✓ Dois sítios de infusão InterLink

✓ Uma alça de sutura opcional e um clamp

✓ Tamanho dos lúmens:• Distal 16GA• Proximal 18GA

Diâmetro externo: 7 FComprimento: 20 cmFio-guia: 0,035” (0,89 mm) x 60 cm

*M2720HE - Kit Duplo lúmen padrão*M3720HE - Kit Triplo lúmen padrão*A2720HE - Kit duplo lúmen Vantex*A3720HE - Kit triplo lúmen Vantex

EU RepresentativeEdwards Lifesciences Service GmbH Edisonstr 6D - 85716 Unterschleissheim Germany

Fabricante:Edwards Lifesciences LLCIrvine, CA 92614-5686-USA.Importado e distribuído por:Edwards LifesciencesEdwards Lifesciences C.P.M.C. Ltda. I.E.: 103.478.199.119Registro ANVISA No. 80219050065

Edwards Lifesciences, Edwards, o logo estilizado E, Multi Med, Vantex, AMC THROMBOSHIELD, são marcas registradas da Edwards Lifesciences Corporation e estão registradas no Escritório de Marcas e Patentes dos EUA. LA-out/10-72RV1

EU

Sa0

5

Diâ

met

ro d

a zo

na

de

inib

ição

(m

m)

10

15

20

25

30

Se Sf Ec

com cobertura AMC

sem cobertura

Sm Pa

Sa: S.aureus

Se: S.epidermidis

Sf: S.faecalis

Ec: E. coli

Sm: S. marcescens

Pa: P. aeruginosa

Inibição do crescimento microbianocom a cobertura AMC THROMBOSHIELD

Teste in vitro de difusão em Ágar Soja Tríptico, que demonstra que o espectro dacobertura AMC THROMBOSHIELD está centrada no S.epidermidis. Os microorganismos testados representam as bactérias mais comuns isoladas de cateteres infectados. 1, 2* Diminui a contagem de microorganismos viáveis na superfície do cateter durantesua manipulação e inserção.A significativa atividade anti-microbiana com AMC THROMBOSHIELD tem sidodemonstrada usando ensaios de difusão em ágar, contra os seguintes microorganis-mos: Staphylococcus epidermidis, Staphylococcus aureus, Streptococcus faecalis,lbicans, Escherochia coli, Serratia marcescens e Acinetobactercalcoaceticus.