FUT. 7 305 10 11 12 13 14 15 301 N 304 5103009 302 EA EA 4 306 307 308 FUT. 6 FUT. 5 FUT. 4 FUT. 9 FUT. 8 FUT. 3 FUT. 2 FUT. 1 3 2 1 ANDREWS CI 177170 6077305 24792 199414 24781 201 R W B R W B 310 177168 202 203 19 RP737553 0 SP176449 1 SP144730 0 SP150450 REFER TO DETAIL "A" LANGLEY ROAD NEW ROAD E 204 311 5163111 3 RP737553 2 RP737553 1 RP737553 50 RP734536 49 RP734536 0 SP174882 0 BUP71185 0 BUP70654 20 RP734535 19 RP734535 WARNING-EXISTING SERVICES & LIVE CABLES IN THE AREA.REFER TO NOTE 20. 5105085 312 101 102 313 177169 EA OVER EXISTING EA OVER EXISTING CE EA OVER EXISTING WARNING-EXISTING SERVICES & LIVE CABLES IN THE AREA.REFER TO NOTE 20. 1. FOR STANDARD UNDERGROUND DUCT SECTIONS REFER TO UNDERGROUND CONSTRUCTION MANUAL DRAWING 5168. 2. POLYMERIC COVER TO BE INSTALLED OVER CONDUITS OUTSIDE NORMAL ERGON ALIGNMENT AS PER ERGON DRAWING. 5022-1 AND 5124-1 & 2. 3. STANDARD TRENCH ALIGNMENT IS 0.3 TO 1.2 METRES OFF PROPERTY ALIGNMENT SUBJECT TO LOCATION OF OTHER SERVICES. REFER TO UNDERGROUND CONSTRUCTION MANUAL DRAWING 5228. 4. STREETLIGHT POLE FOOTINGS SHALL BE LOCATED PERPENDICULAR TO THE KERB AND SQUARE FROM THE FRONT BOUNDARY PEG ENSURING NO CONFLICT WITH FUTURE DRIVEWAYS, UNLESS DETAILED OTHERWISE. WHERE DIMENSIONS ARE SHOWN, THEY TAKE PRECEDENCE OVER GRID COORDINATES. 5. ALL CONDUITS SHALL BE CONTINUOUS UNLESS DETAILED OTHERWISE. 6. REFER TO UNDERGROUND CONSTRUCTION MANUAL DRAWING 5162 FOR CONDUIT BEND DETAILS AT PILLARS. 7. FOR STANDARD UDC CONSTRUCTION PRACTICES REFER TO DRAWINGS 5022, 5085 AND 5124. 8. INSTALLATION OF PADMOUNT SUBSTATION REQUIRED IN ROAD RESERVE ADJACENT LOT 10, STATION 1. PADMOUNT SITE IS TO BE 6.0m x 4.0m, REFER TO UNDERGROUND CONSTRUCTION MANUAL DRAWING 5114. REFER TO DETAIL 'A'. 9. DEVELOPER SHALL INSTALL PLINTH AND PAVED CUTOUT AREA. REFER TO UNDERGROUND CONSTRUCTION MANUAL DRAWINGS SUBSTATIONS 5274 & 5276. 10. INSTALL PADMOUNTED SUBSTATION EARTHING - COMMON EARTH ARRANGEMENT. REFER TO UNDERGROUND CONSTRUCTION MANUAL DRAWING 5123. 11. THERE ARE 2 x 17W LED SYLVANIA STREET, AEROSCREEN MINOR ROAD ON RATE 2. 12. STREETLIGHT DESIGN TO AS1158 CATEGORY P4. 13. MINOR STREETLIGHTS - THE DEVELOPER SHALL SUPPLY AND INSTALL STREETLIGHT BASES. FOUNDATION DEPTH IS 1200mm FOR MINOR STREETLIGHTS.REFER TO LIGHTING CONSTRUCTION MANUAL DRAWING 1-6-4-1 & 2. FOR ALL FOOTPATHS, CENTRELINE OF STREETLIGHT SHALL BE 0.82m FROM THE INVERT OF KERB AND CHANNEL. WHERE THE ROAD IS UN-KERBED OR THERE IS A FLUSH KERB, CENTRELINE OF STREETLIGHT SHALL BE 1.3m FROM THE OUTER EDGE OF THE BITUMEN. 14. THE LIGHTING DESIGN INCLUDES AN ALLOWANCE FOR CONSTRUCTION TOLERANCE OF LIGHT POLES SUCH THAT ANY STREETLIGHT CAN BE POSITIONED UP TO A MAXIMUM OF ±350mm LONGITUDINALLY FROM THE POSITION SHOWN AND UP TO 100mm MAXIMUM FURTHER AWAY FROM KERB EDGE, INCLUDING POLES WITH GRID COORDINATES, AND STILL MAINTAIN COMPLIANCE. 15. CONFIRM ALL CONDUIT AND CABLE LENGTHS PRIOR TO INSTALLATION. 16. WHERE SHOWN, 35mm sq ANNEALED BARE Cu EARTH SHALL BE INSTALLED AT BOTTOM OF TRENCH, IN NATURAL SOIL, BELOW BEDDING SAND, LOCATED A MINIMUM OF 50mm HORIZONTALLY TOWARDS PROPERTY BOUNDARY FROM CONDUITS (HV OR LV) INSTALLED ON PROPERTY BOUNDARY SIDE OF TRENCH. COIL 2m OF CABLE AT SPECIFIED STATIONS IN THE CONDUIT DUCTING SCHEDULE AND ALL REQUIRED JOINTS FOR CONNECTION BY ELECTRICAL CONTRACTOR. THE USE OF THE EARTH ROD CONNECTOR (U-BOLT, IIN. 0719437 ) IS NOT ACCEPTABLE FOR CONDUCTOR / CABLE TO CONDUCTOR / CABLE CONNECTIONS. IN ADDITION PARALLEL GROOVE CLAMPS ARE NOT ACCEPTABLE FOR JOINTING OR CONNECTING EARTHS BELOW GROUND LEVEL. ACCEPTABLE METHODS SHALL BE EITHER A CRIMP LINK OR A 'C' TYPE COMPRESSION CONNECTOR. CRIMP LINKS AND 'C' TYPE COMPRESSION CONNECTORS ARE AVAILABLE FROM ERGON ENERGY STORES IIN. 0157746 AND IIN. 2406222 RESPECTIVELY. 17. IN ACCORDANCE WITH ELECTRICAL SAFETY ACT, A SAFETY OBSERVER MUST BE PRESENT AT ALL TIMES WHEN WORKING IN THE VICINITY OF ENERGISED CABLES. CONTACT ERGON ENERGY ON 131046. 18. ELECTRONIC CABLE MARKERS (ECM'S) ARE TO BE SUPPLIED AND INSTALLED AT ENDS OF ALL SPARE CONDUITS INCLUDING (SPARE ROAD CROSSINGS, CONDUIT STUBS, FOR FUTURE STAGES, SPARE CONDUITS FOR FUTURE HV, ETC) AND AT ALL CABLE JOINTS. REFER TO ERGON STANDARD SPECIFICATIONS RSC07, RSC08, & RSM02. 19. ALL CONTRACTORS MUST CARRY OUT A DIAL BEFORE YOU DIG ENQUIRY BEFORE COMMENCING ANY EXCAVATION. 20. WARNING: LIVE CABLES AND EXISTING SERVICES IN AREA. CONTRACTOR TO USE POT HOLING, HYDRO-VAC EXCAVATION AND CABLE LOCATION WHEN INSTALLING NEW INFRASTRUCTURE. 21. ERGON WORKS: - ERGON ENERGY TO CUT INTO EXISITNG LV CABLE AT STN 203 BETWEEN STN 301 (5105085) TO STN 307 (24792) AND CONNECT TO THE NEW COILED CABLE FED FROM SUBSTATION 1. - ERGON ENERGY TO RECOVER EXISTING PILLAR STN 302 (177170). CONNECTING THE EXISTING CABLE AT STN 202 FROM STN 310 (177168) TO THE NEW COILED CABLE FED FROM SUBSTATION 1. - ERGON ENERGY TO RECOVER EXISTING PILLAR AT STN 305 AND CONNECT CABLES VIA A NEW UNDERGROUND CABLE JOINT AT STN 201 TO EXISITNG 4x1C 300mm² AI/XLA/PVC. - ERGON ENERGY TO RECOVER EXISTING 315kVA POLE MOUNTED TRANSFORMER AT STN 301 (5105085). - ERGON ENERGY TO RECOVER LV CABLE & TERMINATION BETWEEN STN 301 TO STN 202. - ERGON ENERGY TO RECOVER LV CABLE & TERMINATION BETWEEN STN 301 TO STN 203. - ERGON ENERGY TO INSTALL HV CABLE TERMINATION BETWEEN STN 1 TO STN 301. - ERGON ENERGY TO INSTALL LV CABLE TERMINATION BETWEEN STN 1 TO 301. WORKPLAN NOTES 301 304 5103009 4 3 2 1 5105085 201 202 203 NOTE: CONDUITS SHOWN ARE INDICATIVE ONLY. DO NOT USE AS REFERENCE FOR CONDUIT LAYING. REFER TO CONDUIT SCHEDULE FOR STATION TO STATION DETAILS AND CONDUIT BEND INFORMATION. REFER TO SITE PLAN AND WORKPLAN NOTES FOR TRENCH SECTION DETAILS. CIVIL INSTALLERS NOTE: EACH PILLAR REQUIRES 2 x 40mm LEAD IN CONDUITS. BENDS TO BE INSTALLED AS PER ERGON STANDARD DRAWINGS. REFER TO DETAIL "A" 101 102 204 ON COMPLETION, MARK UP THIS PRINT CLEARLY WITH ALL FINAL CHANGES AND RETURN TO PROJECT MANAGER CHANGES: YES/NO ELECTRICAL CONTRACTOR NAME: SIGNATURE: DATE: CIVIL CONTRACTOR NAME: SIGNATURE: DATE: FOR CONSTRUCTION SPA LIGHTING DESIGN COMPLIANCE CERTIFICATE FOR LIGHTING ARRANGEMENT, SPACINGS, MOUNTING HEIGHTS, OUTREACH DETAILS AND SIGNIFICANT ROAD FEATURES, REFER TO DRAWING. MAINTENANCE FACTOR 0.75 ALL LIGHTING CALCULATIONS ARE AVAILABLE UPON REQUEST. THIS LIGHTING DESIGN COMPLIES GENERALLY WITH THE NOMINATED CATEGORIES OF AS1158 FOR RATE 1 AND RATE 2 LUMINAIRES. LIGHTING CATEGORIES: CATEGORY P4 NAME: JANE ERREY TITLE: SENIOR ELECTRICAL ENGINEER RPEQ: 6863 DOUGLAS SHIRE COUNCIL LOCAL COUNCIL: THE DESIGN ASSUMES MAINTENANCE FACTORS OF 0.75 FOR MINOR ROAD LIGHTING AND 0.75 FOR MAJOR ROAD LIGHTING. THESE MAINTENANCE FACTORS ARE BASED ON THE FOLLOWING MAINTENANCE SCHEDULE, WHICH MIGHT NOT NECESSARILY BE ADOPTED BY ERGON. 1. LAMPS SHALL BE REPLACED AT 36- MONTH INTERVALS. 2. ALL THAT TIME, LUMINARIES SHALL BE CLEANED, INSPECTED AND MAINTAINED. 3. VEGETATION SHALL BE KEPT CLEAR OF STREET LIGHTS. 4. INSPECTION PATROLS AND SPOT LAMP REPLACEMENT SHALL MAINTAIN SERVICE AVAILABILITY AT NO LESS THAN 95%. 5. LUMINARIES AND LAMPS SHALL BE REPLACED WITH EXACT EQUIVALENTS. PROPERTY BOUNDARY 4.00 SHARED TRENCH LOT 10 FUT. LOT 9 6.00 CABLE SAND PIT LV TO EX. STN 203 LV TO EX. STN 301 LV TO EX. STN 202 LV TO EX. STN 204 LV TO EX. STN 2 HV TO EX. STN 301 HV TO EX. STN 204 LV TO EX. STN 204 Description Date Code CLIENT: Tel: (07) 4032 3311 Fax: (07) 4032 5633 Email Address - [email protected] PO Box 664 North Cairns QLD 4870 A business unit of SPA Consulting Engineers (QLD) Pty Ltd a.c.n. 0108444416 any use of this drawing is forbidden without this company's consent Drawing Title Project Description consulting engineers Simon Perkins & Associates Ph Fax Fax Ph Description Date Code LEGEND ZERO LOT BOUNDARY HV DUCT LV DUCT LIGHTING DUCT 35mm sq ANNEALED BARE COPPER EARTH CABLE EXISTING CABLE PLANNED CABLE RECOVER SUBSTATION HV ISOLATING DEVICE LV ISOLATING DEVICE NORMAL PILLAR CROSS ROAD PILLAR LINKING PILLAR COMMERCIAL/ INDUSTRIAL PILLAR DISTRIBUTION CABINET STREETLIGHT EARTH POLE CABLE JOINT Revised EQUIPMENT RECOVER EQUIPMENT EXISTING EQUIPMENT PLANNED Revision SPA Drawing Number RPEQ Design Certification Drawn Date Scale ERGON Project Number Sheet 3205-E01 Revised Jane Errey 6863 LANGLEY ROAD, PORT DOUGLAS, QLD LANGLEY RD & ANDREW CI STAGE 1 UDC UG ELECTRICAL RETICULATION SITE PLAN & CONDUIT SCHEMATIC AND DETAIL A JANUARY 2020 1:500 @A1 TM 1 OF 2 WR1537708 A SEYMOUR GROUP LEVEL 24, 300 QUEEN STREET BRISBANE, QLD 4000 0438882024 GHD PTY LTD (CAIRNS) 85 SPENCE STREET CAIRNS, QLD 4870 040442261 CIVIL ENGINEER 5 0 -5 10 15 20 25 1:500 @ A1 SITE PLAN CONDUIT SCHEMATIC A 20/05/20 FOR CONSTRUCTION TM DETAIL "A" - SUBSTATION 1

ANDREWS CI - Douglas Shire Council...4 install pillar lv pn1/6s/240/n 5025 101 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 102 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 201 install

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ANDREWS CI - Douglas Shire Council...4 install pillar lv pn1/6s/240/n 5025 101 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 102 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 201 install

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

FUT.

7

305

10

11

12

13

14

15

301

N

304

5103009

302

EA

EA

4

306

307 308

FUT.

6

FUT.

5

FUT.

4

FUT.

9

FUT.

8

FUT.

3

FUT.

2

FUT.

1

3

2

1

A

N

D

R

E

W

S

C

I

177170

6077305

24792

199414

24781

201

R

W

B

R

W

B

310

177168

202

203

19

RP737553

0

SP176449

1

SP144730

0

SP150450

REFER TO

DETAIL "A"

LANGLEY ROAD

NE

W R

OA

D E

204

311

5163111

3

RP737553

2

RP737553

1

RP737553

50

RP734536

49

RP734536

0

SP174882

0

BUP71185

0

BUP70654

20

RP734535

19

RP734535

WARNING-EXISTING

SERVICES & LIVE CABLES

IN THE AREA.REFER TO

NOTE 20.

5105085

312

101

102

313

177169

EA OVER EXISTING

EA OVER EXISTING

CE

EA OVER EXISTING

WARNING-EXISTING

SERVICES & LIVE CABLES

IN THE AREA.REFER TO

NOTE 20.

1. FOR STANDARD UNDERGROUND DUCT SECTIONS REFER TO UNDERGROUND CONSTRUCTION MANUAL DRAWING 5168.

2. POLYMERIC COVER TO BE INSTALLED OVER CONDUITS OUTSIDE NORMAL ERGON ALIGNMENT AS PER ERGON DRAWING. 5022-1 AND

5124-1 & 2.

3. STANDARD TRENCH ALIGNMENT IS 0.3 TO 1.2 METRES OFF PROPERTY ALIGNMENT SUBJECT TO LOCATION OF OTHER SERVICES. REFER

TO UNDERGROUND CONSTRUCTION MANUAL DRAWING 5228.

4. STREETLIGHT POLE FOOTINGS SHALL BE LOCATED PERPENDICULAR TO THE KERB AND SQUARE FROM THE FRONT BOUNDARY PEG

ENSURING NO CONFLICT WITH FUTURE DRIVEWAYS, UNLESS DETAILED OTHERWISE. WHERE DIMENSIONS ARE SHOWN, THEY TAKE

PRECEDENCE OVER GRID COORDINATES.

5. ALL CONDUITS SHALL BE CONTINUOUS UNLESS DETAILED OTHERWISE.

6. REFER TO UNDERGROUND CONSTRUCTION MANUAL DRAWING 5162 FOR CONDUIT BEND DETAILS AT PILLARS.

7. FOR STANDARD UDC CONSTRUCTION PRACTICES REFER TO DRAWINGS 5022, 5085 AND 5124.

8. INSTALLATION OF PADMOUNT SUBSTATION REQUIRED IN ROAD RESERVE ADJACENT LOT 10, STATION 1. PADMOUNT SITE IS TO BE 6.0m x

4.0m, REFER TO UNDERGROUND CONSTRUCTION MANUAL DRAWING 5114. REFER TO DETAIL 'A'.

9. DEVELOPER SHALL INSTALL PLINTH AND PAVED CUTOUT AREA. REFER TO UNDERGROUND CONSTRUCTION MANUAL DRAWINGS

SUBSTATIONS 5274 & 5276.

10. INSTALL PADMOUNTED SUBSTATION EARTHING - COMMON EARTH ARRANGEMENT. REFER TO UNDERGROUND CONSTRUCTION MANUAL

DRAWING 5123.

11. THERE ARE 2 x 17W LED SYLVANIA STREET, AEROSCREEN MINOR ROAD ON RATE 2.

12. STREETLIGHT DESIGN TO AS1158 CATEGORY P4.

13. MINOR STREETLIGHTS - THE DEVELOPER SHALL SUPPLY AND INSTALL STREETLIGHT BASES. FOUNDATION DEPTH IS 1200mm FOR MINOR

STREETLIGHTS.REFER TO LIGHTING CONSTRUCTION MANUAL DRAWING 1-6-4-1 & 2. FOR ALL FOOTPATHS, CENTRELINE OF STREETLIGHT

SHALL BE 0.82m FROM THE INVERT OF KERB AND CHANNEL. WHERE THE ROAD IS UN-KERBED OR THERE IS A FLUSH KERB, CENTRELINE

OF STREETLIGHT SHALL BE 1.3m FROM THE OUTER EDGE OF THE BITUMEN.

14. THE LIGHTING DESIGN INCLUDES AN ALLOWANCE FOR CONSTRUCTION TOLERANCE OF LIGHT POLES SUCH THAT ANY STREETLIGHT CAN

BE POSITIONED UP TO A MAXIMUM OF ±350mm LONGITUDINALLY FROM THE POSITION SHOWN AND UP TO 100mm MAXIMUM FURTHER

AWAY FROM KERB EDGE, INCLUDING POLES WITH GRID COORDINATES, AND STILL MAINTAIN COMPLIANCE.

15. CONFIRM ALL CONDUIT AND CABLE LENGTHS PRIOR TO INSTALLATION.

16. WHERE SHOWN, 35mm sq ANNEALED BARE Cu EARTH SHALL BE INSTALLED AT BOTTOM OF TRENCH, IN NATURAL SOIL, BELOW BEDDING

SAND, LOCATED A MINIMUM OF 50mm HORIZONTALLY TOWARDS PROPERTY BOUNDARY FROM CONDUITS (HV OR LV) INSTALLED ON

PROPERTY BOUNDARY SIDE OF TRENCH. COIL 2m OF CABLE AT SPECIFIED STATIONS IN THE CONDUIT DUCTING SCHEDULE AND ALL

REQUIRED JOINTS FOR CONNECTION BY ELECTRICAL CONTRACTOR. THE USE OF THE EARTH ROD CONNECTOR (U-BOLT, IIN. 0719437 ) IS

NOT ACCEPTABLE FOR CONDUCTOR / CABLE TO CONDUCTOR / CABLE CONNECTIONS. IN ADDITION PARALLEL GROOVE CLAMPS ARE NOT

ACCEPTABLE FOR JOINTING OR CONNECTING EARTHS BELOW GROUND LEVEL. ACCEPTABLE METHODS SHALL BE EITHER A CRIMP LINK

OR A 'C' TYPE COMPRESSION CONNECTOR. CRIMP LINKS AND 'C' TYPE COMPRESSION CONNECTORS ARE AVAILABLE FROM ERGON

ENERGY STORES IIN. 0157746 AND IIN. 2406222 RESPECTIVELY.

17. IN ACCORDANCE WITH ELECTRICAL SAFETY ACT, A SAFETY OBSERVER MUST BE PRESENT AT ALL TIMES WHEN WORKING IN THE

VICINITY OF ENERGISED CABLES. CONTACT ERGON ENERGY ON 131046.

18. ELECTRONIC CABLE MARKERS (ECM'S) ARE TO BE SUPPLIED AND INSTALLED AT ENDS OF ALL SPARE CONDUITS INCLUDING (SPARE ROAD

CROSSINGS, CONDUIT STUBS, FOR FUTURE STAGES, SPARE CONDUITS FOR FUTURE HV, ETC) AND AT ALL CABLE JOINTS. REFER TO

ERGON STANDARD SPECIFICATIONS RSC07, RSC08, & RSM02.

19. ALL CONTRACTORS MUST CARRY OUT A DIAL BEFORE YOU DIG ENQUIRY BEFORE COMMENCING ANY EXCAVATION.

20. WARNING: LIVE CABLES AND EXISTING SERVICES IN AREA. CONTRACTOR TO USE POT HOLING, HYDRO-VAC EXCAVATION AND CABLE

LOCATION WHEN INSTALLING NEW INFRASTRUCTURE.

21. ERGON WORKS:

- ERGON ENERGY TO CUT INTO EXISITNG LV CABLE AT STN 203 BETWEEN STN 301 (5105085) TO STN 307 (24792) AND CONNECT TO THE

NEW COILED CABLE FED FROM SUBSTATION 1.

- ERGON ENERGY TO RECOVER EXISTING PILLAR STN 302 (177170). CONNECTING THE EXISTING CABLE AT STN 202 FROM STN 310

(177168) TO THE NEW COILED CABLE FED FROM SUBSTATION 1.

- ERGON ENERGY TO RECOVER EXISTING PILLAR AT STN 305 AND CONNECT CABLES VIA A NEW UNDERGROUND CABLE JOINT AT STN

201 TO EXISITNG 4x1C 300mm² AI/XLA/PVC.

- ERGON ENERGY TO RECOVER EXISTING 315kVA POLE MOUNTED TRANSFORMER AT STN 301 (5105085).

- ERGON ENERGY TO RECOVER LV CABLE & TERMINATION BETWEEN STN 301 TO STN 202.

- ERGON ENERGY TO RECOVER LV CABLE & TERMINATION BETWEEN STN 301 TO STN 203.

- ERGON ENERGY TO INSTALL HV CABLE TERMINATION BETWEEN STN 1 TO STN 301.

- ERGON ENERGY TO INSTALL LV CABLE TERMINATION BETWEEN STN 1 TO 301.

WORKPLAN NOTES

301

304

5103009

4

3

2

1

5105085

201

202

203

NOTE:

CONDUITS SHOWN ARE INDICATIVE

ONLY. DO NOT USE AS REFERENCE

FOR CONDUIT LAYING. REFER TO

CONDUIT SCHEDULE FOR STATION

TO STATION DETAILS AND CONDUIT

BEND INFORMATION. REFER TO SITE

PLAN AND WORKPLAN NOTES FOR

TRENCH SECTION DETAILS.

CIVIL INSTALLERS NOTE:

EACH PILLAR REQUIRES 2 x 40mm

LEAD IN CONDUITS. BENDS TO BE

INSTALLED AS PER ERGON

STANDARD DRAWINGS.

REFER TO

DETAIL "A"

101

102

204

ON COMPLETION, MARK UP THIS PRINT

CLEARLY WITH ALL FINAL CHANGES AND

RETURN TO PROJECT MANAGER

CHANGES: YES/NO

ELECTRICAL CONTRACTOR

NAME:

SIGNATURE:

DATE:

CIVIL CONTRACTOR

NAME:

SIGNATURE:

DATE:

FOR CONSTRUCTION

SPA LIGHTING DESIGN COMPLIANCE CERTIFICATE

FOR LIGHTING ARRANGEMENT, SPACINGS, MOUNTING HEIGHTS, OUTREACH

DETAILS AND SIGNIFICANT ROAD FEATURES, REFER TO DRAWING.

MAINTENANCE FACTOR 0.75

ALL LIGHTING CALCULATIONS ARE AVAILABLE UPON REQUEST.

THIS LIGHTING DESIGN COMPLIES GENERALLY WITH THE NOMINATED

CATEGORIES OF AS1158 FOR RATE 1 AND RATE 2 LUMINAIRES.

LIGHTING CATEGORIES:

CATEGORY P4

NAME: JANE ERREYTITLE: SENIOR ELECTRICAL ENGINEER

RPEQ: 6863

DOUGLAS SHIRE COUNCILLOCAL COUNCIL:

THE DESIGN ASSUMES MAINTENANCE FACTORS OF 0.75 FOR MINOR ROAD

LIGHTING AND 0.75 FOR MAJOR ROAD LIGHTING. THESE MAINTENANCE FACTORS

ARE BASED ON THE FOLLOWING MAINTENANCE SCHEDULE, WHICH MIGHT NOT

NECESSARILY BE ADOPTED BY ERGON.

1. LAMPS SHALL BE REPLACED AT 36- MONTH INTERVALS.

2. ALL THAT TIME, LUMINARIES SHALL BE CLEANED, INSPECTED AND

MAINTAINED.

3. VEGETATION SHALL BE KEPT CLEAR OF STREET LIGHTS.

4. INSPECTION PATROLS AND SPOT LAMP REPLACEMENT SHALL MAINTAIN

SERVICE AVAILABILITY AT NO LESS THAN 95%.

5. LUMINARIES AND LAMPS SHALL BE REPLACED WITH EXACT EQUIVALENTS.

PROPERTY BOUNDARY

4.00

SHARED TRENCH

LOT 10

FUT. LOT 9

6.00

CABLE SAND PIT

LV TO EX. STN 203

LV TO EX. STN 301

LV TO EX. STN 202

LV TO EX. STN 204LV TO EX. STN 2

HV TO EX. STN 301

HV TO EX. STN 204

LV TO EX. STN 204

DescriptionDateCode

CLIENT:

Tel: (07) 4032 3311 Fax: (07) 4032 5633

Email Address - [email protected]

PO Box 664 North Cairns QLD 4870

A business unit of SPA Consulting Engineers (QLD) Pty Ltd a.c.n. 0108444416

any use of this drawing is forbidden without this company's consent

Drawing Title

Project Description

consulting engineers

Simon Perkins & Associates

Ph Fax

FaxPh

DescriptionDateCode

LEGEND

ZERO LOT BOUNDARY

HV DUCT

LV DUCT

LIGHTING DUCT

35mm sq ANNEALED

BARE COPPER EARTH

CABLE EXISTING

CABLE PLANNED

CABLE RECOVER

SUBSTATION

HV ISOLATING DEVICE

LV ISOLATING DEVICE

NORMAL PILLAR

CROSS ROAD PILLAR

LINKING PILLAR

COMMERCIAL/ INDUSTRIAL PILLAR

DISTRIBUTION CABINET

STREETLIGHT

EARTH

POLE

CABLE JOINT

Revised

EQUIPMENT RECOVER

EQUIPMENT EXISTING

EQUIPMENT PLANNED

RevisionSPA Drawing Number

RPEQ Design Certification

Drawn

Date

Scale

ERGON Project Number

Sheet

3205-E01

Revised

Jane Errey 6863

LANGLEY ROAD,

PORT DOUGLAS, QLD

LANGLEY RD & ANDREW CI STAGE 1

UDC UG ELECTRICAL RETICULATION

SITE PLAN & CONDUIT SCHEMATIC

AND DETAIL A

JANUARY 2020

1:500 @A1

TM

1 OF 2

WR1537708 A

SEYMOUR GROUP

LEVEL 24, 300 QUEEN STREET

BRISBANE, QLD 4000

0438882024

GHD PTY LTD (CAIRNS)

85 SPENCE STREET

CAIRNS, QLD 4870

040442261

CIVIL ENGINEER

50-5 10 15 20 25

1:500 @ A1

SITE PLAN

CONDUIT SCHEMATIC

A 20/05/20 FOR CONSTRUCTION TM

DETAIL "A" - SUBSTATION 1

AutoCAD SHX Text
C
Page 2: ANDREWS CI - Douglas Shire Council...4 install pillar lv pn1/6s/240/n 5025 101 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 102 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 201 install

ON COMPLETION, MARK UP THIS PRINT

CLEARLY WITH ALL FINAL CHANGES AND

RETURN TO PROJECT MANAGER

CHANGES: YES/NO

ELECTRICAL CONTRACTOR

NAME:

SIGNATURE:

DATE:

CIVIL CONTRACTOR

NAME:

SIGNATURE:

DATE:

FOR CONSTRUCTION

Rev Date

24-4-19

CONDUIT DUCTING SCHEDULE

STN

FROM

STN

TO

ACTION CONSTRUCTION CODE

LENGTH

(m)

No. of

LENGTHS /

DRUM

BENDS

(Degrees/ Radius(mm) x No.)

Remarks

1 1 INSTALL - CIVIL C125L 1 0.2

90/1000x3 60/1000x3

45/1000x2

1 1 INSTALL - CIVIL C100L 1 0.2 90/1000x6

1 2 INSTALL - CIVIL C80L 42 7.0 45/1830x3

1 202 INSTALL - CIVIL C80L 36 6.0

1 203 INSTALL - CIVIL C80L 40 6.7

1 204 INSTALL - CIVIL C80L 44 7.3

CAP CONDUIT AT STN

STN 204.

1 204 INSTALL - CIVIL C80L 44 7.3

CAP CONDUIT AT STN

STN 204.

1 204 INSTALL - CIVIL C40H 44 11.0

CAP CONDUIT AT STN

204.

1 204 INSTALL - CIVIL C125L 45 7.5

CAP CONDUIT AT STN

204.

1 301 INSTALL - CIVIL C80L 40 6.7

CAP CONDUIT 1M FROM

BASE OF STN 301.

1 301 INSTALL - CIVIL C125L 45 7.5 45/1830x2

CAP CONDUIT 1M FROM

BASE OF STN 301.

2 3 INSTALL - CIVIL C80L 26 4.3 45/1830x2

2 4 INSTALL - CIVIL 35mm2 ANNEALED BARE

Cu EARTH

52 0.2 COIL 2M OF CABLE AT

STN 4 FOR CONNECTION

BY ELECTRICAL

CONTRACTOR.LEAVE AT

BOTTOM OF TRENCH AT

STN 2.

2 101 INSTALL - CIVIL C40H 9 2.3 90/300x2

3 4 INSTALL - CIVIL C80L 26 4.3 45/1830x2

4 102 INSTALL - CIVIL C40H 9 2.3 90/300x2 90/600x1 ADDITIONAL BEND TO

AVOID NBN PIT.

Rev Date

24-1-18

CONSTRUCTION SCHEDULE

STN NO

SITE

LABEL

POLE

ALIGNMENT

POLE

SETTING

DEPTH

ACTION CONSTRUCTION CLASS CONSTRUCTION CODE

DRAWING

NUMBER

POSITION

ON POLE

REMARKS

1 INSTALL EARTH E PM22/COM 5123

1 INSTALL HV CABLE TERMINATION 22 CTC/RM6/185T 5279

INSTALL HV TERMINATION FOR

CABLE BETWEEN STN 1 TO STN

304.

1 INSTALL LV CABLE TERMINATION LV CT PM22/240 5087

INSTALL LV TERMINATION FOR

CABLE BETWEEN STN 1 TO STN

2.

1 INSTALL LV CABLE TERMINATION LV CT PM22/240 5087

INSTALL LV TERMINATION FOR

CABLE BETWEEN STN 1 TO STN

202

1 INSTALL LV CABLE TERMINATION LV CT PM22/240 5087

INSTALL LV TERMINATION FOR

CABLE BETWEEN STN 1 TO STN

203.

1 INSTALL LV CABLE TERMINATION LV CT PM22/240 5087

INSTALL LV TERMINATION FOR

CABLE BETWEEN STN 1 TO STN

301.

1 INSTALL SUBSTATION FOUNDATION PMRF 22/41/8 5118 REFER TO NOTE 8.

1 INSTALL SUBSTATION INC HV SWITCHGEAR PMR 22/5/41 RM6 21 590 REFER TO DETAIL 'A'

2 INSTALL PILLAR LV PN2/6S/240/N 5026

3 INSTALL PILLAR LV PN2/6/240/N 5026

4 INSTALL EARTH E MEN/PIL 5085

4 INSTALL PILLAR LV PN1/6S/240/N 5025

101 INSTALL POLE SL BPM/75/1 15 CI 1-6-4-1 & 2

102 INSTALL POLE SL BPM/75/1 15 CI 1-6-4-1 & 2

201

INSTALL -

ERGON

CABLE JOINT LV-CJS240C4 5073 REFER TO NOTE 21.

202 INSTALL CABLE JOINT LV-CJS240C4 5073 REFER TO NOTE 21.

203 INSTALL CABLE JOINT LV-CJS240C4 5073 REFER TO NOTE 21.

301

INSTALL -

ERGON

HV CABLE TERMINATION 22 CT P/185T/P 5076

ERGON TO INSTALL HV

TERMINATION FOR CABLE

BETWEEN STN 1 TO STN 301.

301

RECOVER

- ERGON

LV CABLE TERMINATION

ERGON ENERGY TO RECOVER

EXISTING LV TERMINATION FOR

CABLE BETWEEN STN 1 TO STN

301.

301

INSTALL -

ERGON

LV CABLE TERMINATION LV CT P/240/P/AL 5056

ERGON ENERGY TO INSTALL LV

TERMINATION FOR CABLE

BETWEEN STN 1 TO STN 301.

301

RECOVER

- ERGON

LV CABLE TERMINATION

ERGON ENERGY TO RECOVER

EXISTING LV TERMINATION FOR

CABLE BETWEEN STN 301 TO

STN 302.

301 5105085 EXISTING POLE

301 5105085 RECOVER

- ERGON

POLE MOUNTED TRANSFORMER

REFER TO NOTE 21.

302 177170 RECOVER

- ERGON

PILLAR ERGON ENERGY TO RECOVER

EXISITNG PILLAR. REFER TO

NOTE 21.

304 5103009 EXISTING POLE

304 5103009 EXISTING WOOD POLE BRACKET

305 RECOVER

- ERGON

PILLAR ERGON ENERGY TO RECOVER

EXISITNG PILLAR. REFER TO

NOTE 21.

306 24781 EXISTING PILLAR

307 24782 EXISTING PILLAR

308 199414 EXISTING PILLAR

310 177168 EXISTING PILLAR

311 5163111 EXISTING POLE

311 5163111 EXISTING WOOD POLE BRACKET

312 6077305 EXISTING POLE

313 177169 EXISTING PILLAR

Rev Date

02-07-18

UNDERGROUND CABLE SCHEDULE

STN

FROM

STN

TO

ACTION VOLTAGE

CONSTRUCTION

CODE

ROUTE

LENGTH

CABLE

LENGTH

REMARKS

1 2 INSTALL 415V LV-240C4/673 42 46

1 202 INSTALL 415V LV-240C4/673 36 48

COIL CABLE AT STN 202 FOR

CONNECTION BY ERGON

ENERGY. REFER TO NOTE 21.

1 203 INSTALL 415V LV-240C4/673 40 52

COIL CABLE AT STN 203 FOR

CONNECTION BY ERGON

ENERGY. REFER TO NOTE 21.

1 301 INSTALL 22kV 22-185T/1834 45 70

COIL CABLE AT STN 301 FOR

CONNECTION BY ERGON

ENERGY.

1 301 INSTALL 415V LV-240C4/673 40 65

COIL CABLE AT STN 301 FOR

CONNECTION BY ERGON

ENERGY.

2 3 INSTALL 415V LV-240C4/673 26 30

2 101 INSTALL 240V LVI-4CU2NS/1671 9 14

3 4 INSTALL 415V LV-240C4/673 26 30

4 102 INSTALL 240V LVI-4CU2NS/1671 9 14

301 203 RECOVER -

ERGON

415V LV-240C4/673 6 23 ERGON ENERGY TO

RECOVER CABLE BETWEEN

STN 301 & STN 203. REFER

TO NOTE 21.

301 302 RECOVER -

ERGON

415V LV-240C4/673 6 23 ERGON ENERGY TO

RECOVER CABLE BETWEEN

STN 301 & STN 302. REFER

TO NOTE 21.

Rev Date

29-8-19

PUBLIC LIGHTING SCHEDULE

STN NO SITE LABEL ACTION

CONSTRUCTION

CODE

RATE TARIFF OWNER

MOUNTING

HEIGHT (m)

REMARKS

101 INSTALL SLED GL 0167 N RATE 2 DSC 7.5

102 INSTALL SLED GL 0167 N RATE 2 DSC 7.5

304 5103009 EXISTING

311 5163111 EXISTING

315kVA SUBSTATION

ADJACENT LOT 10

STATION 1

4C240mm

STATION 2

LOT 10/11

4C240mm

STATION 3

LOT 12/13

4C240mm

STATION 4

LOT 14/15

4C240mm

STATION 202

CABLE JOINT

4C240mm

EX. PILLAR

STATION 307

24792

EX. PILLAR

STATION 308

199414

STATION 203

CABLE JOINT

EX. PILLAR

STATION 310

177168

EX. POLE

STATION 311

5163111

EXISTING HV/LV POLE

ADJACENT LOT 8

STATION 301

4C240mm

315kVA SUBSTATION

ADJACENT LOT 10

STATION 1

EXISTING HV/LV POLE

ADJACENT LOT 8

STATION 301

3C185mm

HV CABLE

Rev Date

24-1-18

ERGON WORKS SCHEDULE

STN

NO

SITE

LABEL

POLE

ALIGNMENT

POLE

SETTIN

G

DEPTH

ACTION

CONSTRUCTION

CLASS

CONSTRUCTION

CODE

DRAWING

NUMBER

POSITI

ON ON

POLE

REMARKS

201

INSTALL

- ERGON

CABLE JOINT LV-CJS240C4 5073 REFER TO NOTE 21.

202

INSTALL

- ERGON

CABLE JOINT LV-CJS240C4 5073 REFER TO NOTE 21.

203

INSTALL

- ERGON

CABLE JOINT LV-CJS240C4 5073 REFER TO NOTE 21.

301

INSTALL

- ERGON

HV CABLE

TERMINATION

22 CT P/185T/P 5076

ERGON TO INSTALL HV

TERMINATION FOR

CABLE BETWEEN STN 1

TO STN 301.

301

RECOVE

R -

ERGON

LV CABLE

TERMINATION

ERGON ENERGY TO

RECOVER EXISTING LV

TERMINATION FOR

CABLE BETWEEN STN 301

TO STN 302.

301

INSTALL

- ERGON

LV CABLE

TERMINATION

LV CT P/240/P/AL 5056

ERGON ENERGY TO

INSTALL LV TERMINATION

FOR CABLE BETWEEN

STN 1 TO STN 301.

301

RECOVE

R -

ERGON

LV CABLE

TERMINATION

ERGON ENERGY TO

RECOVER EXISTING LV

TERMINATION FOR

CABLE BETWEEN STN 1

TO STN 301.

301 5105085

RECOVE

R -

ERGON

POLE MOUNTED

TRANSFORMER

REFER TO NOTE 21.

302 177170

RECOVE

R -

ERGON

PILLAR

ERGON ENERGY TO

RECOVER EXISITNG

PILLAR. REFER TO NOTE

21.

305

RECOVE

R -

ERGON

PILLAR

ERGON ENERGY TO

RECOVER EXISITNG

PILLAR. REFER TO NOTE

21.

DescriptionDateCode

CLIENT:

Tel: (07) 4032 3311 Fax: (07) 4032 5633

Email Address - [email protected]

PO Box 664 North Cairns QLD 4870

A business unit of SPA Consulting Engineers (QLD) Pty Ltd a.c.n. 0108444416

any use of this drawing is forbidden without this company's consent

Drawing Title

Project Description

consulting engineers

Simon Perkins & Associates

Ph Fax

FaxPh

DescriptionDateCode

LEGEND

ZERO LOT BOUNDARY

HV DUCT

LV DUCT

LIGHTING DUCT

35mm sq ANNEALED

BARE COPPER EARTH

CABLE EXISTING

CABLE PLANNED

CABLE RECOVER

SUBSTATION

HV ISOLATING DEVICE

LV ISOLATING DEVICE

NORMAL PILLAR

CROSS ROAD PILLAR

LINKING PILLAR

COMMERCIAL/ INDUSTRIAL PILLAR

DISTRIBUTION CABINET

STREETLIGHT

EARTH

POLE

CABLE JOINT

Revised

EQUIPMENT RECOVER

EQUIPMENT EXISTING

EQUIPMENT PLANNED

RevisionSPA Drawing Number

RPEQ Design Certification

Drawn

Date

Scale

ERGON Project Number

Sheet

3205-E02

Revised

Jane Errey 6863

LANGLEY ROAD,

PORT DOUGLAS, QLD

LANGLEY RD & ANDREW CI STAGE 1

UDC UG ELECTRICAL RETICULATION

SCHEMATICS , DETAIL "A" & SCHEDULES

AND ERGON WORKS SCHEDULE

JANUARY 2020

NTS

TM

2 OF 2

WR1537708 A

SEYMOUR GROUP

LEVEL 24, 300 QUEEN STREET

BRISBANE, QLD 4000

0438882024

GHD PTY LTD (CAIRNS)

85 SPENCE STREET

CAIRNS, QLD 4870

040442261

CIVIL ENGINEER

A FOR CONSTRUCTION TM

LV SCHEMATIC

20/05/20

HV SCHEMATIC

AutoCAD SHX Text
C
Page 3: ANDREWS CI - Douglas Shire Council...4 install pillar lv pn1/6s/240/n 5025 101 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 102 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 201 install

FSA:

STATE: REGION:

SAM:

DRAFTER

ADA:

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

DRAWING TITLE:

PROJECT No:

SCALE SHEET No. REV.

QUALITY RECORD :

APPROVED

NBNCO APPROVAL RECORD:

DD

AB

WD

REV DATE DESCRIPTION

SIGNATURE DATE

NBNCO DISCLAIMER

CADREF No:

NN KEY PLAN

OF

STRICTLY CONFIDENTIAL

THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR THE USE OFNBNCO LIMITED (ABN 86 136 533 741) FOR USE IN MAINTAININGNBNCO FACILITIES. IT HAS NOT BEEN CREATED FOR ANY OTHERUSE. IT SHOULD NOT BE SCALED TO LOCATE NBNCO ASSETS. NOWARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE ORCOMPLETE.

ENABLE#:

Cairns : (07) 4032 3311

Email Address - [email protected]

PO Box 664 North Cairns QLD 4870

SPA Consulting Engineers (QLD) Pty Ltd a.c.n. 0108444416

consulting engineers

Simon Perkins & Associates

Townsville : (07) 4728 3026

3205-T01

LANGLEY ROAD & ANDREW CLOSE SUBDIVISIONNBNCo PIT AND PIPE DESIGNLAYOUT PLAN

QLD DSC

STG - W000114372

AS SHOWN 1 2 1

1 20/05/20 TM FOR APPROVAL JE

-

-

-

-

-

-

-

LEGEND

PIT-ID8

PIT-ID5

PIT-ID2 NBN Co PIT TYPE 2

PLASTIC PIT OR SIMILAR

NBN Co PIT TYPE 5

PLASTIC PIT OR SIMILAR

NBN Co PIT TYPE 8

PLASTIC PIT OR SIMILAR

LOCAL CONDUIT (P100/P50)

CAP SERVICE CONDUIT (P50/P20)

P20=P23 mm NBNCo SERVICE

CONDUIT

EXISTING CONDUIT

END CAP CONDUIT WITH

STATION NO.

NBNCo STAGE BOUNDARY

SHARED TRENCH

ZERO LOT PROPERTY

BOUNDARY

TRANSFORMER / KIOSK / PAD

MOUNT SUB-STATION / POLE

MOUNT TRANSFORMER

P20

PIT-ID8 EXISTING NBN Co PIT

3.5

PIT-ID6 NBN Co PIT TYPE 6

PLASTIC PIT OR SIMILAR

5 EXISTING TELSTRA PIT

( 2,3,4,5,6,7,8,9 )

STANDARD DESIGN NOTES:

1. THERE ARE A TOTAL OF 6 SINGLE RESIDENTIAL DWELLINGS.

2. REFER TO SPA DRAWING 3205-E01-E02. FOR COORDINATION WITH THE

ELECTRICAL DESIGN.

CONDUITS AND DUCTS ARE IN LAYER:

< L460 NBN Support - Underground >

AND TERMINOLOGY CATEGORISED INTO TWO GROUPS IN

THE DRAWINGS AS PER BELOW:

1- DUCT USED WITH LOCAL NETWORK

2-CONDUIT USED WITH LEAD-IN DROPS

ATTRIBUTES ATTACHED TO CONDUITS ARE AS SHOWN

CONDUIT SIZE

CONDUIT LENGTH

CONDUIT CONFIGURATION

NOTE:

· P100 HAS AN INTERNAL DIAMETER OF 104.9 mm AND A MINIMUM WALL

THICKNESS OF 4.5 mm

· P50 HAS AN INTERNAL DIAMETER OF 53 mm AND A MIMIMUM WALL

THICKNESS OF 3.1 mm

· P20 HAS AN INTERNAL DIAMETER OF 23.3 mm AND A MINIMUM WALL

THICKNESS OF 1.4 mm

26.5P100PIT-ID8

PIT-ID5

STANDARD CONSTRUCTION NOTES:

1. REFER TO NBN Co DOCUMENT NO. NBN-TE-CTO-194 (DEPLOYMENT OF THE NBN Co CONDUIT AND PIT NETWORK -

GUIDELINES FOR DEVELOPERS) FOR DETAILED CONSTRUCTION SPECIFICATION.

2. MULTIPLE 15° CONDUIT BENDS TO BE USED TO SWING IN AND OUT OF THE STANDARD TRENCH ALIGNMENT AND ENTER

THE NARROW ENDS OF THE PIT.

3. PITS TO INCLUDE LID GASKET TO PREVENT DIRT ENTRY AND SPREADER BARS TO PREVENT PIT BUCKLING DURING

BACKFILL / GROUND COMPACTION. PIT LIDS TO BE EMBOSSED WITH "NBN" AND COMPLY AS PER CLAUSE 5.3.2 OF THE

ABOVE NBN Co DOCUMENT.

4. SERVICE CONDUITS TO EXTEND 1m INSIDE THE FRONT PROPERTY BOUNDARY. REFER EXTENDED SERVICE CONDUIT

DETAIL FOR DISTANCES FROM DIVIDING PROPERTY BOUNDARY FOR BOUNDARIES WITHOUT PIT. CONTRACTORS TO TIE

TELECOMMUNICATIONS CAUTION TAPE TO END OF SERVICE CONDUITS AND EXTEND TO ABOVE GROUND LEVEL FOR

FUTURE CONDUIT LOCATION.

5. ALL CONDUITS TO ENTER AND EXIT AT NARROW ENDS OF PITS ONLY. LOCATE CONDUITS AS CENTRALLY IN PIT END

WALLS AS POSSIBLE. CONDUITS SHALL NOT BE INSTALLED WITHIN 50 mm OF ANY CORNER OF THE PIT. MINIMUM

SEPARATION BETWEEN CONDUITS TO BE 25 mm. INSTALL CONDUITS AND CONDUIT COLLARS (BUSHES) TO BE SQUARE

AND FLUSH WITH THE PIT END WALL. REFER TO THE PIT END WALL DETAILS IN THIS DESIGN FOR ADDITIONAL

REQUIREMENTS.

6. MINIMUM COVER TO BE; 300 mm FOR SERVICE DROP CONDUITS, 450 mm IN VERGE, 600 mm UNDER LOCAL ROADS, AND 800

mm UNDER MAIN ROADS.

7. CONDUITS ARE TO BE CLEANED AND PROVEN USING A MANDREL. AFTER TESTING INSTALL A SUITABLE DRAW ROPE TO

ALL CONDUITS AND CAP CONDUIT ENDS. SEAL CONDUITS AT PITS TO PREVENT ENTRY OF DUST AND MOISTURE. SERVICE

CONDUIT DRAW ROPES TO BE ADDITIONALLY FITTED WITH A PLASTIC LABEL AT PIT END, IDENTIFYING LOT NUMBER AND

DISTANCE / DIRECTION FROM BOUNDARY.

8. INSTALL NON CONDUCTIVE (METAL FREE) MARKER TAPE ABOVE ALL NBN Co CONDUITS, 300 mm BELOW FINISHED GROUND

LEVEL. INSTALL METALLIC KERB MARKERS AT ROAD CROSSINGS.

9. REFER TO ERGON ENERGY STANDARD DRAWINGS 5228 AND 5168 SHEETS 1 TO 3 FOR SHARED TRENCH CROSS SECTIONS.

10. GRADE TOP OF PIT TO MATCH VERGE / FOOTPATH.

11. WHERE REQUIRED, SUPPLY AND INSTALL SERVICE AND ROAD CROSSING CONDUITS SHOWN IN THE SITE PLAN.

12. WHERE CONDUIT BURIAL DEPTH IS LESS THAN THAT SPECIFIED IN THE NBN Co DEPLOYMENT OF CONDUIT AND PIT

NETWORK GUIDELINES, SUPPLY AND INSTALL CONCRETE COVER (FOR VERGE AND FOOTPATH) / CONCRETE ENCASEMENT

(FOR ROADWAYS) ENSURE THAT MINIMUM SEPARATION TO ALL OTHER SERVICES ARE MAINTAINED.

13. WHERE SPECIFIED ON THE SITE PLAN, NBN Co CONDUIT TO BE INSTALLED UNDERNEATH STORM WATER. REFER TO THE

NBN Co DEPLOYMENT OF CONDUIT AND PIT NETWORK GUIDELINES FOR THE MINIMUM CLEARANCES REQUIRED.

14. SUPPLY AND INSTALL ADDITIONAL DEVIATING CONDUIT BENDS TO ACHIEVE THE INCREASED / DECREASED BURIAL DEPTH

REQUIRED TO AVOID CLASH WITH OTHER SERVICES.

FOR APPROVAL

NOT FOR CONSTRUCTION

LAYOUT PLAN

SCALE 1:500 @ A1

LANGLEY ROAD

ANDREWS CLOSE

10

13

14

15

11

12

2019

RP737553

PIT-0015

CAP CONDUIT 1M FROM

EXISTING FOR CONNECTION

TO EXISTING NETWORK

BY OTHERS

PIT-0118

0

RP734536

FUT.

7

FUT.

5

FUT.

6

FUT.

9

RP734536

FUT.

8

19

RP737553 SP176449

0 1

SP144730

3

RP737553

2

RP737553

49

1

50

SP174882

RP734535RP734535

RP737553

4

PIT-0038

PIT-0025

P100

26

13

P100

P100

27

P100

P10014

P203.5

P203.5

P203.5

P203.5

P203.5

P203.5

CAP CONDUIT FOR

FUTURE NBNCo PROVISION

CAP CONDUIT AT STAGE

BOUNDARY FOR CONNECTION

TO EXISTING NBN Co NETWORK

BY OTHERS. DO NOT CONNECT

TO EXISTING CONDUITS / PIT.

N

P100

83

SDU Development InformationDevelopment Name:

Developer Company:

Authorised Rep:

Development Address:

nbn Reference Number: Stage Number:

Phone:E-Mail:

Design Revision:1

20-30 LANGLEY ROAD, PORT DOUGLAS 4877

[email protected] 4728 3026

1STG - W000114372

TIMOTHY MATTHEWS

LANGLEY ROAD & ANDREWS CLOSE SUBDIVISION

SEYMOUR GROUP

BILL OF MATERIAL

PITSSIZE25

89

QTYDUCTS

SIZE QTY MTRSP100P50P20

TOTAL NUMBER OF PITS:

TOTAL NUMBER OF CONDUITS:TOTAL LENGTH OF CONDUITS:

NO OF LOTS:

TOTAL NUMBER OF MANHOLES:

6

02010

5 1630 06 21

3011184

6

AutoCAD SHX Text
STAFF WORKING ON THIS ESTIMATE PLEASE NOTE: The location of other authorities services which may affect this work have not been obtained by the estimator. Constructor to obtain service information before commencing.
AutoCAD SHX Text
SAFETY FIRST SAFETY STARTS WITH YOU
Page 4: ANDREWS CI - Douglas Shire Council...4 install pillar lv pn1/6s/240/n 5025 101 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 102 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 201 install

FSA:

STATE: REGION:

SAM:

DRAFTER

ADA:

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

DRAWING TITLE:

PROJECT No:

SCALE SHEET No. REV.

QUALITY RECORD :

APPROVED

NBNCO APPROVAL RECORD:

DD

AB

WD

REV DATE DESCRIPTION

SIGNATURE DATE

NBNCO DISCLAIMER

CADREF No:

NN KEY PLAN

OF

STRICTLY CONFIDENTIAL

THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR THE USE OFNBNCO LIMITED (ABN 86 136 533 741) FOR USE IN MAINTAININGNBNCO FACILITIES. IT HAS NOT BEEN CREATED FOR ANY OTHERUSE. IT SHOULD NOT BE SCALED TO LOCATE NBNCO ASSETS. NOWARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE ORCOMPLETE.

ENABLE#:

Cairns : (07) 4032 3311

Email Address - [email protected]

PO Box 664 North Cairns QLD 4870

SPA Consulting Engineers (QLD) Pty Ltd a.c.n. 0108444416

consulting engineers

Simon Perkins & Associates

Townsville : (07) 4728 3026

3205-T02

LANGLEY RD & ANDREW CL SUBDIVISIONNBNCo PIT AND PIPE DESIGNTYPICAL PIT LAYOUTS AND TRENCH DETAILS

QLD DSC

STG - W000114372

AS SHOWN 2 2 1

1 20/05/20 TM FOR APPROVAL JE

-

-

-

-

-

-

-

EXCLUSION

ZONE

LOT PROPERTY B

FRONT PROPERTY BOUNDARY

TYPICAL PIT DETAIL 2

TYPE 5 PIT

TYPE 6

& 8 PITTYPE 2 PIT

DIV

ID

IN

G B

OU

ND

AR

Y

"x"

"y"

SHARED

TRENCH

ALLOCATION

400

4

0

0

400

400

ERGON

PILLAR

REFER TO ERGON

STANDARD

TRENCHING

DRAWINGS FOR

APPLICABLE

SHARED TRENCH

ALIGNMENTS

ZERO LOT

BOUNDARY

PIT OFFSET FROM BOUNDARY WITH AN ERGON PILLAR (ZERO LOT BOUNDARY).

1500 MAX

800 MAX

- ENSURE PIT TO BE CLEAR OF THE ZERO LOT BOUNDARY

EXCLUSION

ZONE

FRONT PROPERTY BOUNDARY

LOT PROPERTY B

TYPE 5 PIT

TYPE 6

& 8 PIT

TYPE 2 PIT

DIV

ID

IN

G B

OU

ND

AR

Y

"x"

"y"

REFER TO ERGON

STANDARD

TRENCHING

DRAWINGS FOR

APPLICABLE

SHARED TRENCH

ALIGNMENTS

SHARED

TRENCH

ALLOCATION

400

4

0

0

400

400

ERGON

PILLAR

100 MIN

ERGON CROSS

ROAD CONDUIT

TYPICAL PIT DETAIL 3

LOT

PROPERTY A

PIT OFFSET FROM BOUNDARY WITH AN ERGON PILLAR AND 90° ERGON CONDUIT.

400

950 MAX

1650 MAX

- ENSURE 100 mm MIN CLEARANCE TO ERGON CROSS ROAD CONDUIT

EXCLUSION

ZONE

FRONT PROPERTY BOUNDARY

TYPICAL PIT DETAIL 4

TYPE 5 PIT

TYPE 6

& 8 PIT

TYPE 2 PIT

DIV

ID

IN

G B

OU

ND

AR

Y

"x"

"y"

SHARED

TRENCH

ALLOCATION

400

4

0

0

400

400

ERGON

PILLAR

>

1

0

0

MIN.

CLEARANCE

PIT AND ERGON

CONDUIT IS 100

mm

ERGON CROSS

ROAD CONDUIT

REFER TO ERGON

STANDARD

TRENCHING

DRAWINGS FOR

APPLICABLE

SHARED TRENCH

ALIGNMENTS

LOT PROPERTY BLOT PROPERTY A

PIT OFFSET FROM BOUNDARY WITH AN ERGON PILLAR AND ANGLED ERGON CONDUIT.

950 MAX

1650 MAX

- LOCATE FAR END OF PIT AS CLOSE AS POSSIBLE TO THE PROLONGATION OF

DIVIDING BOUNDARY WHILST MAINTAINING A MINIMUM OF 100 mm CLEARANCE FROM

ERGON CONDUIT(S) TO MINIMISE DRIVEWAY INTRUSION.

FRONT PROPERTY BOUNDARY

SHARED TRENCH ALLOCATION

TYPE 5 PIT

TYPE 2 PIT

TYPE 6 &

8 PIT

S

I

D

E

P

R

O

P

E

R

T

Y

B

O

U

N

D

A

R

Y

S

H

A

R

E

D

T

R

E

N

C

H

A

L

L

O

C

A

T

I

O

N

LOT PROPERTY A

9

0

°

SHARED TRENCH ALLOCATION

"

x

"

"

y

"

"x"

"y"

"y"

REFER BELOW

NOTE

REFER TO ERGON

STANDARD

TRENCHING

DRAWINGS FOR

APPLICABLE

SHARED TRENCH

ALIGNMENTS

TYPICAL PIT DETAIL 8

PIT OFFSET FROM PROPERTY TRUNCATION POINT.

- LOCATE END OF PIT AS CLOSE AS PRACTICABLE TO THE TRUNCATION. WHERE APPLICABLE MAINTAIN REQUISITE

COMPLIANCE TO FIGURE 13 IN THE NBN DEPLOYMENT GUIDELINES NBN-CTO-194.

EXCLUSION ZONE

FRONT PROPERTY BOUNDARY

TYPICAL PIT DETAIL 7

LOT PROPERTY B

TYPE 5 PIT

TYPE 6 &

8 PITTYPE 2 PIT

"x"

"y"

SHARED

TRENCH

ALLOCATION

400

4

0

0

400

ERGON

PILLAR

REFER TO ERGON

STANDARD

TRENCHING

DRAWINGS FOR

APPLICABLE

SHARED TRENCH

ALIGNMENTS

FR

ON

T P

RO

PE

RT

Y B

OU

ND

AR

Y

D

I

V

I

D

I

N

G

B

O

U

N

D

A

R

Y

PIT OFFSET FROM BOUNDARY WITH AN ERGON PILLAR ON CORNER LOT.

LOT

PROPERTY A

- LOCATE END OF PIT AS CLOSE AS PRACTICABLE TO THE INTERSECTING

PROPERTY BOUNDARIES WHILST MAINTAINING CLEARANCE TO PILLAR

EXCLUSION ZONE TO MINIMISE DRIVEWAY INTRUSION.

EXCLUSION

ZONE

FRONT PROPERTY BOUNDARY

TYPICAL PIT DETAIL 6

LOT PROPERTY BLOT PROPERTY A

TYPE 6

& 8 PIT

DIV

ID

IN

G B

OU

ND

AR

Y

"x"

"y"

SHARED

TRENCH

ALLOCATION

400

4

0

0

400

400

ERGON

PILLAR

REFER TO ERGON

STANDARD

TRENCHING

DRAWINGS FOR

APPLICABLE

SHARED TRENCH

ALIGNMENTS

WATER MAIN

"z"

TYPE 8 PIT OFFSET FROM BOUNDARY WITH AN ERGON PILLAR AND CLASHING WITH WATER MAIN.

150 mm (MIN)

TYPE 5 PIT

TYPE 2 PIT

- LOCATE END OF PIT AS CLOSE AS POSSIBLE TO THE PROLONGATION OF DIVIDING

BOUNDARY WHILST MAINTAINING MINIMUM 150 mm CLEARANCE FROM WATER MAIN TO

MINIMISE DRIVEWAY INTRUSION.

2000 MAX

1350 MAX

EXCLUSION

ZONE

FRONT PROPERTY BOUNDARY

TYPICAL PIT DETAIL 5

TYPE 5 PIT

TYPE 6

& 8 PITTYPE 2 PIT

DIV

ID

IN

G B

OU

ND

AR

Y

"x"

"y"

SHARED

TRENCH

ALLOCATION

400

4

0

0

400

400

ERGON

PILLAR

REFER TO ERGON

STANDARD

TRENCHING

DRAWINGS FOR

APPLICABLE

SHARED TRENCH

ALIGNMENTS

PIT OFFSET FROM BOUNDARY WITH AN ERGON PILLAR AND FIRE HYDRANT.

LOT

PROPERTY A

LOT

PROPERTY B

- LOCATE END OF PIT AS CLOSE AS POSSIBLE TO THE PROLONGATION OF

DIVIDING BOUNDARY WHILST MAINTAINING MINIMUM 150 mm CLEARANCE

FROM FIRE HYDRANT AND MARGIN SETT TO MINIMISE DRIVEWAY INTRUSION.

1350 MAX

2000 MAX

150

MIN

150 MIN

WATER MAIN

SEPARATION FROM ERGON

CONDUITS

ERGON

CONDUIT

TYPE

PARALLEL

SEPARATION

(mm)

CROSSING

SEPARATION

(mm)

LV/SL 100 100

HV 300 100

300

350 VERGE

"x"

"y"

600 MINOR ROAD

1200 M

AJO

R R

OA

D

80 mm LV CONDUIT

40 mm SL CONDUIT

125 mm HV CONDUIT

NBNCo MARKER TAPE

ERGON MARKER TAPE

450 VERGE

800 MAJOR ROAD

500 ROADWAY

900 M

IN

OR

R

OA

D

750 F

OO

TP

AT

H

1200 M

AJO

R R

OA

D

1050 M

IN

OR

R

OA

D

900 F

OO

TP

AT

H

HV

LV

HV

LV LV

STANDARD TRENCH SECTION

SCALE 1:25 @ A1

100 mm NBNCo CONDUIT

(25 mm SEPARATION)

REFER TO ERGON STANDARD

TRENCHING DRAWINGS FOR APPLICABLE

SHARED TRENCH ALIGNMENTS

PROPERTY

BOUNDARY PEG

NBN Co PIT SIZES

PIT TYPE NAME

NOMINAL EXTERNAL

DIMENSIONS (mm)

MINIMUM INTERNAL

DIMENSIONS (mm)

LENGTH WIDTH DEPTH LENGTH WIDTH DEPTH

SERVICE DROP ACCESS PIT TYPE 2 650 280 565 490 150 500

SERVICE DROP ACCESS PIT or BOUNDARY

PIT or FJL PIT

TYPE 5 700 450 650 510 290 540

TYPE 6 1360 555 650 1130 340 600

TYPE 8 1360 555 860 1130 390 820

DIV

ID

IN

G P

RO

PE

RT

Y B

OU

ND

AR

Y

<1000

SHARED TRENCH ALLOCATION

<1000

10001000

REFER APPLICABLE

COUNCIL REGION

FOR SHARED TRENCH

ALIGNMENT

TO PIT

FRONT PROPERTY

BOUNDARY

20/50 mm NBNCo

EXTENDED SERVICE

CONDUIT

LOT

PROPERTY A

LOT

PROPERTY B

EXTENDED SERVICE CONDUITS TO DISTANT PIT

300

50 (m

in)

TYPE 2 PIT

TYPICAL PIT END WALL DETAILS

SCALE 1:25 @ A1

300

450

25 (min)

50 (m

in)

450

25 (min)

50 (m

in)

TYPE 5 PIT

TYPE 8 PIT

TYPE 6 PIT

25 (min)

25 (min)

25 (m

in)

25 (min)

50 (min)

25 (min)

25 (min)

25 (min)

20/50 mm

SERVICE CONDUITS

50/100 mm

CONDUITS

20/50 mm

SERVICE CONDUITS

50/100 mm

CONDUITS

20 mm

SERVICE CONDUITS

50 mm

CONDUIT

20/50/100 mm

CONDUITS

450

TYPICAL PIT DETAILS

NOTES:

1. THESE DETAILS REPRESENT TYPICAL PIT CONFIGURATIONS

AND THE CONTRACTOR SHALL DETERMINE THE MOST

SUITABLE DETAIL FOR EACH PARTICULAR APPLICATION,

IGNORING REDUNDANT DETAILS.

2. PITS SHALL BE INSTALLED CLEAR OF DRIVEWAYS AND

FUTURE DRIVEWAY LOCATIONS. COORDINATE FINAL

LOCATIONS WITH CIVIL DRAWINGS.

3. ENSURE PITS ARE INSTALLED IN ACCORDANCE WITH NBN

Co GUIDELINES AND THE FOLLOWING CLEARANCES:

A. 100 mm FROM LV / 300 mm FROM HV ELECTRICAL

CONDUITS

B. 150 mm FROM WATER RETICULATION

C. 150 mm FROM SEWER RETICULATION & 300mm FROM

MAINS

D. 150 mm FROM STORMWATER RETICULATION

4. MIRROR CONFIGURATION WHERE APPROPRIATE

EXCLUSION

ZONE

FRONT PROPERTY BOUNDARY

TYPICAL PIT DETAIL 1

TYPE 5 PIT

TYPE 6

& 8 PIT TYPE 2 PIT

DIV

ID

IN

G B

OU

ND

AR

Y

"x"

"y"

SHARED

TRENCH

ALLOCATION

400

4

0

0

400

400

ERGON

PILLAR

REFER TO ERGON

STANDARD

TRENCHING

DRAWINGS FOR

APPLICABLE

SHARED TRENCH

ALIGNMENTS

PIT CENTRAL TO THE BOUNDARY WITH AN ERGON PILLAR.

LOT

PROPERTY A

LOT

PROPERTY B

- INSTALL CENTRE OF PIT IN LINE WITH PROLONGATION

OF DIVIDING BOUNDARY.

800

MAX

400

MAX

SCALE 1:25 @ A1

SERVICE DROP ACCESS PIT or LN PIT or

FJL PIT

DISTRIBUTION PIT or LN CONNECTION PIT

20/50mm SERVICE

CONDUITS

340

FOR APPROVAL

NOT FOR CONSTRUCTION

AutoCAD SHX Text
DETAILS REPRESENT TYPICAL PIT CONFIGURATIONS REPRESENT TYPICAL PIT CONFIGURATIONS TYPICAL PIT CONFIGURATIONS PIT CONFIGURATIONS CONFIGURATIONS THE CONTRACTOR SHALL DETERMINE THE MOST CONTRACTOR SHALL DETERMINE THE MOST SHALL DETERMINE THE MOST DETERMINE THE MOST THE MOST MOST DETAIL FOR EACH PARTICULAR APPLICATION, FOR EACH PARTICULAR APPLICATION, EACH PARTICULAR APPLICATION, PARTICULAR APPLICATION, APPLICATION, REDUNDANT DETAILS. DETAILS. SHALL BE INSTALLED CLEAR OF DRIVEWAYS AND BE INSTALLED CLEAR OF DRIVEWAYS AND INSTALLED CLEAR OF DRIVEWAYS AND CLEAR OF DRIVEWAYS AND OF DRIVEWAYS AND DRIVEWAYS AND AND DRIVEWAY LOCATIONS. COORDINATE FINAL LOCATIONS. COORDINATE FINAL COORDINATE FINAL FINAL WITH CIVIL DRAWINGS. CIVIL DRAWINGS. DRAWINGS. PITS ARE INSTALLED IN ACCORDANCE WITH NBN ARE INSTALLED IN ACCORDANCE WITH NBN INSTALLED IN ACCORDANCE WITH NBN IN ACCORDANCE WITH NBN ACCORDANCE WITH NBN WITH NBN NBN GUIDELINES AND THE FOLLOWING CLEARANCES: AND THE FOLLOWING CLEARANCES: THE FOLLOWING CLEARANCES: FOLLOWING CLEARANCES: CLEARANCES: 100 mm FROM LV / 300 mm FROM HV ELECTRICAL mm FROM LV / 300 mm FROM HV ELECTRICAL FROM LV / 300 mm FROM HV ELECTRICAL LV / 300 mm FROM HV ELECTRICAL / 300 mm FROM HV ELECTRICAL 300 mm FROM HV ELECTRICAL mm FROM HV ELECTRICAL FROM HV ELECTRICAL HV ELECTRICAL ELECTRICAL 150 mm FROM WATER RETICULATION & 300mm FROM mm FROM WATER RETICULATION & 300mm FROM FROM WATER RETICULATION & 300mm FROM WATER RETICULATION & 300mm FROM RETICULATION & 300mm FROM & 300mm FROM HIGH PRESSURE MAINS PRESSURE MAINS 150 mm FROM SEWER RETICULATION & 300mm FROM mm FROM SEWER RETICULATION & 300mm FROM FROM SEWER RETICULATION & 300mm FROM SEWER RETICULATION & 300mm FROM RETICULATION & 300mm FROM 150 mm FROM STORMWATER RETICULATION mm FROM STORMWATER RETICULATION FROM STORMWATER RETICULATION STORMWATER RETICULATION RETICULATION E. 100mm FROM OTHER TELECOMMUNICATIONS CARRIERS CONFIGURATION WHERE APPROPRIATE WHERE APPROPRIATE APPROPRIATE
Page 5: ANDREWS CI - Douglas Shire Council...4 install pillar lv pn1/6s/240/n 5025 101 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 102 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 201 install

a.b.n 91 010 844 416

TOWNSVILLE OFFICE

PO Box 4706 KIRWAN Q 4817 8/286 Ross River Road AITKENVALE Q 4814

p 07 4728 3026 www.spaconsulting.com.au

CAIRNS OFFICE

PO Box 664 NORTH CAIRNS Q 4870 144 Pease St MANOORA Q 4870

p 07 4032 3311 [email protected]

Chief Executive Officer 28/05/2020 The Manager PO Box 723 MOSSMAN QLD 4873 Dear Sir/Madam, APPROVAL FOR UNDERGROUND WORKS, ELECTRICITY SUPPLY AND STREET LIGHTING - OUR PROJECT No: 3205 We are writing on behalf of Ergon Energy to advise of the following works at the above location. Ergon Energy proposes to conduct underground works in accordance with the enclosed Plans, Drawing No. 3205 – E01, 3205 – E02. Could you please advise whether you have any objection to these works, in your capacity as the Statutory Body having control or management of the roadway. We advise that negotiations with the subdivider, KS5 Pty Ltd, are finalised for the provision of underground electricity reticulation to Langley Rd & Andrew CI Subdivision Stage 1. An agreement has been entered into with the subdivider, whereby Ergon Energy will provide underground electricity reticulation for residential purposes to the 6 lots being developed. Under one of the terms of this agreement, an undertaking has been given that, upon application made in accordance with usual requirements, an underground electricity supply will be made available to the owner or occupier of any allotment forming part of the said land within a reasonable period after receiving such application for supply subject to the availability of materials and other resources. Connection shall be to a new substation Located in Lot 10 of Stage 1. The point of supply for each lot would be at a pillar box on the road boundary. The Subdivider has made arrangements for the installation of 2 x 17W LED Sylvania street aeroscreen minor light fittings. Could you please advise your acceptance of the Rate 2 tariff for each light fitting and in addition provide Acknowledgement to Written Agreement – Works on Roads as it is now an Ergon requirement at the design submission stage. Your reply within fourteen days would be appreciated to avoid unnecessary delays in the construction of the above works. Yours sincerely Tim Matthews SPA Consulting Engineers (QLD)

Page 6: ANDREWS CI - Douglas Shire Council...4 install pillar lv pn1/6s/240/n 5025 101 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 102 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 201 install

Project Name:

Drawing No: 3205-E01,E02 REV A

Council:

Category Luminaire Type IV

Luminaire Type Luminaire Wattage

Pole Height (m) 5.5

Luminaire Outreach

(m) 0.3

Foundation

Depth (mm) 1200 Outreach (m)

Upcast 5 Uplift (m) 2

Mounting Height

(m) 7.5

Cleaning /

Replacement 36 Months

Lamp LED 17W Pollution Level Medium

Photometric File

StreetLED3 17W 4K

AERO 180805PH IP Rating IP6x

Lamp Type LED LLMF 0.8

Lumens 2009 MF 0.75

SLEDGL0167A

Min Av EH 0.85 Min EH Maint 0.14

Lamp Type 4 Up Maint 10

Road Name

Road Reserve Width

(m)

Distance to Kerb

(m) Offset (m)

Spacing Value

from PlePal S

Min Av EH Min EH Maint Up Maint

Straights

Single

Sided

Straights

Staggered

Curves

(Single or

Staggered)

T-Inter

sections

Pedestrian

Refuges LATMDs

Cul-de-

sacs

Round

abouts

ANDREWS CI 17 4.5 5.48 67.6 0.98 0.14 5

Additional

Comments:

LANGLEY RD & ANDREW CI SUBDIVISION

I certify this design meets the

compliance requirements of AS/NZS

1158.3.1:2005

For curved sections, does a straight line joining successive luminaries lie within

the road reserve or is at least one luminaire located within the hatched area, as

shown in figure 3.1?

Has a luminaire associated with one of the intersecting roads been located within the

hatched area shown in figure 3.1, and where differing levels of Category P lighting are

provided, the luminaire is a type that complies with the higher lighting category?

ELEMENTS FOR THIS ROAD

LIMITING LTPs

Ergon Construction Code

Modelling Software

Used:

Is the maintained horizontal illuminance over the surface not be less

than 3.5 lux for the design areas defined below:

LUMINAIRE / POLE / PHOTOMETRIC INFORMATION TABLE HAS COMPLIANCE WITH THE FOLLOWING ELEMENTS BEEN MET?

Is compliance with the maximum permissible spacing achieved on all straights

and curves?

EXISITNG LIGHTING TO LANGLEY ROAD.

For Tee-intersections, has the first luminaire in the joining road been located no more

than 50% of the maximum spacing detailed in clause 3.2.1 from the limits of the junction

defined by the prolongation of the property lines?

Where pedestrian refuges are located on roads requiring category P lighting, is the

maintained horizontal illuminance over the surface of the refuge, within the design area

shown in figure 3.3, not less than 3.5 Lux?

Do maximum spacing for luminaries in cul-de-sacs comply with Clause 3.2.1.and

are the provisions of Clauses 3.2.5.2, 3.2.5.3 or 3.2.5.4 met?

Roundabouts LATMDs

RESULTS TABLEROAD INFORMATION TABLE

Lighting design compliance is conditional on all lights being operational.

28/05/2020 SPA Road Lighting Certificate

Page 7: ANDREWS CI - Douglas Shire Council...4 install pillar lv pn1/6s/240/n 5025 101 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 102 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 201 install

Network Connection ii:i.: ; :

%''.:ERGONENERGY : i -Subdivision/Street Lighting

Application Form

B

Privacy Notice

Ergon Energy is collecting information on this Application for Network Connection Subdivision/Street Lighting Form for the purpose ofassessing your Connection Application. This may include the collection of your personal information. Your personal infomlation will notbe disclosed to any extemal third parties without your consent. unless authorised or required by law if you wish to apply for access tathis infomiation ar make a privacy complaint. you may contact the Right to Infomlation & Privacy Officer on (07) 3851 6000, or visitergon.com.au to obtain access application and privacy complaint forms. If you have provided personal infomlation of anotherindividual, please ensure that you advise the person about this privacy statement. Our privacy policy is available at ergon.com.au.

Page 8: ANDREWS CI - Douglas Shire Council...4 install pillar lv pn1/6s/240/n 5025 101 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 102 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 201 install

Network Connection Application Form

Davao HAVE THE RIGHT AFFI.ICAf16R?e

This applicationisfor

.'' Developers that have already submitted an online Developer Enquiryl

v' Developers undertaking Underground Distribution Construction (UDC) Projects

.'' Developers or Street Lighting Customers undertaking design and construction for street lighting premises

-' Customers undertaking the subdivision of two or more lots, small developers

This application doesnotapplyto

Na new connect oni or connication alteration. For these connections you will need to complete the

X

X

the removal of an unmetered supply device. For these applications you will need to complete aRequest for the Abolishment of Supply and Removal of Ergon Energy Electrical Assets Form

an unmetered supply device to be mounted on an Ergon Energy pole such as CC'TV. For theseconnections you will need to complete a Network Connection for Watchman Lights and Pole Mounted

an unmeteredjupply device to be mounted on an Ergon Energy pole such as CC'TV. For theseconnections. For these connections you will need to complete a Network Connection of WatchmanLights and Pole Mounted Unmetered Supply Devices Application Form

X

X

an unmetered supp.ly device that is not mounted an Ergon Energy pole. For these connections youwill need to complete an Application for Network Connection of an 'Unmetered Supply Device Form

a load that exceeds 1 500kVA/1=5MVA or where power usage is typically above 4GWh per annum at asingle site or generation over 30kVA. For these connections go to ' 'www.ergon.com.au/network/connections/major-business-connections/major-connections

the connection of a Micro Embedded Generating (micro EG) Unit to an existing supply on the ErgonEnergy Network. Please complete the Application for Network Connection of a Micro EmbeddedGenerating (micro EG) Unit 30kVA and Under form. For these connections go towww,e rgon. com .au/network/contractors-and-industry/solar-pv-installers/ies-n etwo rk-connection-form

HOW TO COMPLETE TH£ AFPI.IEXI;16&7SECTION

e

A

B

C

D

E

F

Ergon Energy Work Request No

Developer/ Street Lighting Customers

Design and Construction Details

Documents to Supplied with the Application

Application Fee

TOBECOMPLETEDBY

All Applicants

All Applicants

All Applicants

All Applicants

For the information of the Applicant

All ApplicantsAuthority to Sign

Page 2 of4 PW000{01 FI 00 Ver 9

Ergon Energy Corporation Limited ABN 50 087 646 062

Page 9: ANDREWS CI - Douglas Shire Council...4 install pillar lv pn1/6s/240/n 5025 101 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 102 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 201 install

Network Connection Application FormSubdivision/StreetLighting

Section AErgon Ener! Work Request NoSECTION B

Developer/Street Lighting Customers Please use BLOCK LETTERS

Project Details

llUPORTANT INFORMATION FOR CUSTOMERS:Applications for Customer Owned and Maintained lighting must have CAD drawings of the installationattached together with the GPS coordinates. (Note: format of GPS coordinate schedule below)

[] I have attached the CAD drawing for the Customer Owned and Maintained Street Lighting

Page 3 of4 PW00010t Flea Ver 9

Ergon Energy Corporation Limited ABN 50 087 646 062

Project Name

Langley Rd & Andrew CI Subdivision Port DouglasStage No.ofLots

6Reference Information

Project Description

Project Drawing Number(s)3205

Average Lot Size (m ') Average Lot Frontage (m)

Lighting Category (argon Owned and Operated, Gi#ed and argon)perated or Customer Owned and Operated}

Number of Lights lijUnderground[] Overhead

Source GPS Location Orientation LoadingDetails

Reason

                           

1. State the full name(s) of the person($) making this application.2. if a registered business, state the full name€s) of the proprietor(s) and the business name in the box below.3. Ef a registered company or other incorporated body, state {he registered name in the box provided.Mr / Mrs / MsMr

Given Names i SurnameDanieIFarquhar

Mr / Mrs / Ms Given Names i Surname

Name of business, company or other incorporated bodyKS5 Pty Ltd

ACN/ABN97 110 280 405

Postal AddressC/ SPA Consulting Engineers (Qld) Pty Ltd, PO Box 4706, Kirwan, Qid

Postcode4817

Phone No.07 3226 8799

Mobile No. I E-mail

dfarquhar@ seymou rg roup.com.auProperty Address Number/Name of StreetLangley Road. Port Douglas

Postcode

Real Property Description NumberLots RP804926

Subdivision Plan Reference

Designated Developer Representative for this application NameConsultant B] / Other []

Company NameSPA Consulting Engineers (Qld) Pty Ltd

AddressPO Box 4706. Kirwan. Qld

Postcode4817

PhoneNo07 4728 3026

Mobile No. [email protected]

Page 10: ANDREWS CI - Douglas Shire Council...4 install pillar lv pn1/6s/240/n 5025 101 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 102 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 201 install

Network Connection Application FormSubdivision/Street Lighting

SECTION CEllDesidh dhd:

Willyou use your own contractors, or Ergon Energy, to carry out this prqect?

Developer Design and Construct {DD&C): Please tick the box if you are usingcontractors approved by Ergon Energy to design and construct your project. This optionIs available if you are developing an underground subdivision and/or public lightingproject.

lil ASR Contractors

Ergon Energy Design and Constructto design and construct.

Please tick this box if you require Ergon Energy[] Ergon Energy

SECTION DFia:WjitiMiabbiiiaa

Plan RequirementsIf "No" indicate date whennformation will be supplied.

(2) Electronic copies of the completed Electrical Design

(1 ) pdf, and {l) dwg. format (For ASR Contractor Projects Only)

Copy of Lot Layout for subdivision in dwg. format (For argon Energy Projects Only)

Copy of Local Government Decision Notice. (For ASR Contractors and ErgonEnergy Projects)

SECTION E

argon Energy is entitled to charge you for the costs it incurs in assessing a connection application under the negotiated process, negotiating withyou and preparing a connection offer. argon Energy may issue you a tax invoice for these costs.

A11tbil#i8 dill:l :ll l:::l l: :! :ill lli : il:::l:£llifc;: :l!:::ii ;:;SiJ £ii £l:I/We sign this application for Network Connection Services and confirm I/we are authorised to make thisapplication.

SECTIONF

SIGNEDFORANDONBEHALFOF

Signature of auth En '

Name of auth representative (print)eu.

Signature of authorised representative

N3M6 6f iOth6Fid f $F iati06 (Flint)

Date: 9.o / S / 2.o

Easettients if Ergon Energy requires any easements. the landowner acknowledges it is the responsibility of the landowner to

Signature Print Name

Consultant details (if not identified in Section B)

Electrical Construction Contractor Details (if known)

Page 4 of4 PW0001 01 FI 00 Ver 9

Ergon Energy Corporation Limited ABN 50 087 646 062

Business NameSPA Consulting Engineers (Qld) Pty LtdContact Person

Timothy MatthewsPhone No.

07 4728 3026Mobile No.

EmaN. [email protected]

Business NameTBC

Contact Person

Phone No Mobile No. Email

Page 11: ANDREWS CI - Douglas Shire Council...4 install pillar lv pn1/6s/240/n 5025 101 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 102 install pole sl bpm/75/1 15 ci 1-6-4-1 & 2 201 install

FNQROC DEVELOPMENT MANUAL Council: ................................Douglas Shire Council........................................................

STATEMENT OF COMPLIANCE OPERATIONAL WORKS DESIGN

This form duly completed and signed by an authorised agent of the Designer shall be submitted with the Operational Works Application for Council Approval. Name of Development: Langley Rd and Andrews Cl subdivision Stage 1 Location of Development: Cnr of Langley Road & Andrews Circuit, Port Douglas Applicant: KS5 Pty Ltd Designer: SPA Consulting Engineers (Qld) It is hereby certified that the Calculations, Drawings, Specifications and related documents submitted herewith have been prepared, checked and amended in accordance with the requirements of the FNQROC Development Manual and that the competed works comply with the requirements therein, except as noted below.

Compliance with the requirements of the Operational Works Design Guidelines

Compliance Yes/No

Non-Compliance refer to non-compliance report /

drawing number Plan Presentation N/A Geometric Road Design N/A Pavements N/A Structures / Bridges N/A Subsurface Drainage N/A Stormwater Drainage N/A Site Re-grading N/A Erosion Control and Stormwater Management N/A Pest Plant Management N/A Cycleway / Pathways N/A Landscaping N/A Water Reticulation N/A Electrical Reticulation and Street Lighting Yes Associated Documentation/ Specification N/A Priced Schedule of Quantities N/A Conscientiously believing the above statements to be true and correct, signed on behalf of: Designer: SPA Consulting Engineers (Qld)................................. RPEQ No:..6863........... Name in Full: Boronia Jane Errey

Signature: . Date:28-05-2020