14
Analysis and Background Analysis and Background Aspects in Large Water Aspects in Large Water Cerenkov Detectors Cerenkov Detectors Jessica Dunmore Jessica Dunmore UC, Irvine UC, Irvine NNN05, Aussois NNN05, Aussois 8 April 2005 8 April 2005

Analysis and Background Aspects in Large Water Cerenkov Detectors

  • Upload
    claus

  • View
    37

  • Download
    0

Embed Size (px)

DESCRIPTION

Analysis and Background Aspects in Large Water Cerenkov Detectors. Jessica Dunmore UC, Irvine NNN05, Aussois 8 April 2005. Outline. T2K signal and background rates Water Č erenkov response model Cross-sections and efficiencies Neutrino energy reconstruction Background rejection - PowerPoint PPT Presentation

Citation preview

Page 1: Analysis and Background Aspects in Large Water Cerenkov Detectors

Analysis and Background Analysis and Background Aspects in Large Water Aspects in Large Water

Cerenkov DetectorsCerenkov Detectors

Jessica DunmoreJessica DunmoreUC, IrvineUC, Irvine

NNN05, AussoisNNN05, Aussois8 April 20058 April 2005

Page 2: Analysis and Background Aspects in Large Water Cerenkov Detectors

OutlineOutline• T2K signal and background

rates

• Water Čerenkov response model– Cross-sections and efficiencies– Neutrino energy reconstruction– Background rejection

• Systematic uncertainties– Near detector(s)– Fast global fit technique

Page 3: Analysis and Background Aspects in Large Water Cerenkov Detectors

T2K ExperimentT2K Experiment

Super-KSuper-K

Kamioka

Tokai

JPARCJPARC

40-50 GeV protons create off-axis beam

Page 4: Analysis and Background Aspects in Large Water Cerenkov Detectors

Neutrino flux at Super-KNeutrino flux at Super-K

Unoscillated flux

Oscillated flux (sin2223=1.0)

Oscillated e flux (sin2213=0.1)

Energy (GeV)

(2.5° off-axis beam from 0.75 MW, 40 GeV protons,assumes 5 years x 1021 POT)

m2=0.0025

Fl

ux /

cm

2 /

5 y

ears

/ 5

0 M

eV

bin

Page 5: Analysis and Background Aspects in Large Water Cerenkov Detectors

CC/NC coherent production: + + 1616O O -- + + 1616O + O +

+ + 1616O O + + 1616O + O + oo

Selection:Selection: Fully contained, Fully contained, single-ring, single-ring,

-like events e-like (showering) no decay electron

Signal:Signal:

Backgrounds:Backgrounds:

Signal and BackgroundsSignal and Backgrounds• From off-axis beam at Super-

KAppearance Appearance ExperimentExperiment

DisappearancDisappearance Experimente Experiment

CCQE: + n + n p + p + -- ee + n + n p + p + ee--

CC single + N + N N’ + N’ + - - + + NC: + N + N N’ + N’ + + +

CC multi’s + N + N N’ + N’ + - - + + ……Beam e

Misidentified muonsNC: + N + N N’ + N’ + + + ...

Page 6: Analysis and Background Aspects in Large Water Cerenkov Detectors

Reconstructing Reconstructing Energy EnergyFor T2K disappearance

True Neutrino EnergyTrue Neutrino Energy Reconstructed Reconstructed Energy Energy

Energy (GeV) Reconstructed Energy (GeV)

NCNCCC otherCC other

(1.0,0.0025)

(1.0,0.0025)

NC NC 1100

y-axis: Events / 5 years / 22.5 kton / 50 MeV bin

True True Reconstructed Reconstructed

Transfer MatricesTransfer MatricesCC QECC QE

CC 1CC 1

True Energy (GeV)

True Energy (GeV)

Reco

nst

ruct

ed E

nerg

y

(GeV

)R

eco

nst

ruct

ed E

nerg

y

(GeV

)

Interaction spectrum = Flux x Cross section x Efficiency

Page 7: Analysis and Background Aspects in Large Water Cerenkov Detectors

ee Appearance Background Appearance Background

• The 0 fitter (POLfit) finds a second ring by testing:Likelihood(2) vs. Likelihood(1e)

Then fits direction and energy fraction of 2nd ring

500MeV/c 0

true P2 = 55.5MeV/crec.M0 =140.4MeV/c2

12

Standardfitter

Plot fromS. Mine

• Largest background is from NC 0 production

Page 8: Analysis and Background Aspects in Large Water Cerenkov Detectors

ee signal vs. background after signal vs. background after 00 fitterfitter

Reconstructed e Energy (GeV)Reconstructed e Energy (GeV)

Events

/ 5

years

/ 2

2.5

kto

n /

50

MeV

bin

(For m2=0.0025 sin2223=1.0 13=9°)

Before 0 fitter:NC background ~ 40 events

After 0 fitter:NC background ~ 10 events

Background estimates by M. Fechner

Page 9: Analysis and Background Aspects in Large Water Cerenkov Detectors

Reconstructed e Energy (GeV)

Events

/ 5

years

/ 2

2.5

kto

n /

50

MeV

bin

ee signal for varied signal for varied 1313 values values(For m2=0.0025 sin2223=1.0)

13=9°13=6°13=3° (sin2213=0.10)(sin2213=0.04)(sin2213=0.01)

Page 10: Analysis and Background Aspects in Large Water Cerenkov Detectors

Systematic uncertaintiesSystematic uncertainties• Precision measurement

of 23 and m223 and

appearance background subtraction require careful control of systematic uncertainties.– Čerenkov detector

reconstruction:• Energy scale (~3%)• Fiducial volume

(~3%)

– Cross sections• CCQE (~10-20%)• Other (~20-50%)

– Flux normalization and shape

• Hadron production model

• Beam geometry

• Beam e

Page 11: Analysis and Background Aspects in Large Water Cerenkov Detectors

Near Detector(s)Near Detector(s)• Systematics may be controlled

by using one or more near detectors.

• Fine-grained detector placed near the target.– Ability to measure relative amounts

of CCQE and nonQE interactions

• Water Cerenkov 2km away from target.– Flux shape matches that at far

detector.– Close to identical response at both

near and far detectors.

Page 12: Analysis and Background Aspects in Large Water Cerenkov Detectors

Global oscillation fitGlobal oscillation fit• A fit has been developed to

determine oscillation parameters with the following capabilities:– varying systematic effects– inclusion of near and far detectors– inclusion of both signal and

background – parameterized detector response

(cross-sections, efficiency, reconstruction)A similar approach has been used in the

Super-K atmospheric neutrino oscillation analysis.

References:Y. Ashie et al., Phys.Rev.Lett.93, 101801 (2004)

G. Fogli, et al., Phys. Rev D66, 053010 (2002)Para and Szleper (hep-ex/0110001)

Page 13: Analysis and Background Aspects in Large Water Cerenkov Detectors

Example global oscillation fitExample global oscillation fitm2=0.0025 sin2223=0.95 13=0°

“Data”Prediction

Best fit Prediction + Systematics

Fit m2

Fit sin2223

Uncertainty: ~2% on m2

23

~1.2% on sin2223

Preliminary example: no inclusion of 280m detector.

Page 14: Analysis and Background Aspects in Large Water Cerenkov Detectors

ConclusionsConclusions• Global fit of oscillation

parameters including systematics, near detectors, and backgrounds is a work in progress.

• Current goals are– Perform sensitivity analysis for

oscillation parameters using different detector configurations.

– Determine effect of systematic uncertainties on T2K sensitivity.

• Method is not limited to Water Cerenkov detectors or to T2K-I experiment