26
1079 Singapore: +65 6779 9091 [email protected] USA: +1 330 486 0001 [email protected] Germany: +49 621 776-4411 [email protected] Pepperl+Fuchs Group www.pepperl-fuchs.com Subject to modifications without notice Copyright Pepperl+Fuchs Special Functions Devices Amplifiers, Counters, Timers & Controls Digital Display Meter ............................................................... 1080 Counter/Timer/Tachometer .................................................... 1084 Terminal Amplifier/Converter ................................................. 1092 Sensor Output Converter ....................................................... 1096 Speed Monitor ......................................................................... 1098 Frequency to Voltage/Curent ................................................. 1100 Zero Speed Monitor................................................................. 1102 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1079Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions D

evicesAmplifiers, Counters, Timers & Controls

Digital Display Meter ............................................................... 1080Counter/Timer/Tachometer .................................................... 1084Terminal Amplifier/Converter ................................................. 1092Sensor Output Converter ....................................................... 1096Speed Monitor ......................................................................... 1098Frequency to Voltage/Curent ................................................. 1100Zero Speed Monitor................................................................. 1102

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 2: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1080 Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Spec

ial F

unct

ions

Dev

ices

• Bright, high contrast 5-digit LED indica-tor

• Leading zero suppression• Adjustable decimal point• Maximum- and minimium-value display

FunctionThe DA5-IU-C permits a simple visualinspection by operating and maintenancepersonnel. It converts the analogue sensoroutput signal into a readable form for thispurpose. Depending on the task or setting,4 ... 20 mA or 0 ... 100 % values can be dis-played.

Scope of delivery:• Process control unit DA5-IU-C• Screw terminal, 7-pin• Clamp clip• Seal• 1 sheet of adhesive symbols

Dimensions

Electrical connection

DA5-IU-CGeneral specificationsPre-selection noneData storage 106 storage cycles or 10 years, EEPROMProgramming keypad-driven menuIndicators/operating meansType 7-segment LED display, redNumber of decades 5Display value digit height 8 mmDisplay interval -19999 ... 99999Decimal point freely adjustableResolution 14 BitScale factor via linear characteristic curveReset maximum value, manuallyKey interlock -Electrical specificationsOperating voltage 10 ... 30 V DCPower consumption 1.5 VAInputImpedance 1 MOhmVoltage max. 30 DCAnalogue voltage input 0 ... 10 V / 2 ... 10 V DCAnalogue current input 0 ... 20 mA / 4 ... 20 mAMechanical specificationsConnection 7-pin screw terminal

max. core cross-section 0.34 ... 1.5 mm2

Mass approx. 50 g

1 2 3 4 5 6 7

max. 19.3

59 6.5

4

22 x

45

48

24

TerminalNo.1234567

10 ... 30 V DC0 V (GND)0 V LATCHLATCHCurrent input0 V input signalVoltage input

1 2 3 4 5 6 7

• Bright, high contrast 5-digit LED indica-tor

• Leading zero suppression• Adjustable decimal point• Maximum- and minimium-value display

FunctionThe DA5-IU-C permits a simple visualinspection by operating and maintenancepersonnel. It converts the analogue sensoroutput signal into a readable form for thispurpose. Depending on the task or setting,4 ... 20 mA or 0 ... 100 % values can be dis-played.

Scope of delivery:• Process control unit DA5-IU-C• Screw terminal, 7-pin• Clamp clip• Seal• 1 sheet of adhesive symbols

Dimensions

Electrical connection

DA5-IU-CGeneral specificationsPre-selection noneData storage 106 storage cycles or 10 years, EEPROMProgramming keypad-driven menuIndicators/operating meansType 7-segment LED display, redNumber of decades 5Display value digit height 8 mmDisplay interval -19999 ... 99999Decimal point freely adjustableResolution 14 BitScale factor via linear characteristic curveReset maximum value, manuallyKey interlock -Electrical specificationsOperating voltage 10 ... 30 V DCPower consumption 1.5 VAInputImpedance 1 MOhmVoltage max. 30 DCAnalogue voltage input 0 ... 10 V / 2 ... 10 V DCAnalogue current input 0 ... 20 mA / 4 ... 20 mAMechanical specificationsConnection 7-pin screw terminal

max. core cross-section 0.34 ... 1.5 mm2

Mass approx. 50 g

1 2 3 4 5 6 7

max. 19.3

59 6.5

4

22 x

45

48

24

TerminalNo.1234567

10 ... 30 V DC0 V (GND)0 V LATCHLATCHCurrent input0 V input signalVoltage input

1 2 3 4 5 6 7

Digital Display Meter

Technical Specifications

• Analog voltage or current• Bright, high contrast 5-digit LED indicator• Leading zero suppression• Adjustable decimal point• Maximum- and minimium-value display

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 3: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1081Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Special Functions Devices

• Bright, high contrast 5-digit LED indica-tor

• Leading zero suppression• Adjustable decimal point• Maximum- and minimium-value display

FunctionThe DA5-IU-C permits a simple visualinspection by operating and maintenancepersonnel. It converts the analogue sensoroutput signal into a readable form for thispurpose. Depending on the task or setting,4 ... 20 mA or 0 ... 100 % values can be dis-played.

Scope of delivery:• Process control unit DA5-IU-C• Screw terminal, 7-pin• Clamp clip• Seal• 1 sheet of adhesive symbols

Dimensions

Electrical connection

DA5-IU-CGeneral specificationsPre-selection noneData storage 106 storage cycles or 10 years, EEPROMProgramming keypad-driven menuIndicators/operating meansType 7-segment LED display, redNumber of decades 5Display value digit height 8 mmDisplay interval -19999 ... 99999Decimal point freely adjustableResolution 14 BitScale factor via linear characteristic curveReset maximum value, manuallyKey interlock -Electrical specificationsOperating voltage 10 ... 30 V DCPower consumption 1.5 VAInputImpedance 1 MOhmVoltage max. 30 DCAnalogue voltage input 0 ... 10 V / 2 ... 10 V DCAnalogue current input 0 ... 20 mA / 4 ... 20 mAMechanical specificationsConnection 7-pin screw terminal

max. core cross-section 0.34 ... 1.5 mm2

Mass approx. 50 g

1 2 3 4 5 6 7

max. 19.3

59 6.5

4

22 x

45

48

24

TerminalNo.1234567

10 ... 30 V DC0 V (GND)0 V LATCHLATCHCurrent input0 V input signalVoltage input

1 2 3 4 5 6 7

• Bright, high contrast 5-digit LED indica-tor

• Leading zero suppression• Adjustable decimal point• Maximum- and minimium-value display

FunctionThe DA5-IU-C permits a simple visualinspection by operating and maintenancepersonnel. It converts the analogue sensoroutput signal into a readable form for thispurpose. Depending on the task or setting,4 ... 20 mA or 0 ... 100 % values can be dis-played.

Scope of delivery:• Process control unit DA5-IU-C• Screw terminal, 7-pin• Clamp clip• Seal• 1 sheet of adhesive symbols

Dimensions

Electrical connection

DA5-IU-CGeneral specificationsPre-selection noneData storage 106 storage cycles or 10 years, EEPROMProgramming keypad-driven menuIndicators/operating meansType 7-segment LED display, redNumber of decades 5Display value digit height 8 mmDisplay interval -19999 ... 99999Decimal point freely adjustableResolution 14 BitScale factor via linear characteristic curveReset maximum value, manuallyKey interlock -Electrical specificationsOperating voltage 10 ... 30 V DCPower consumption 1.5 VAInputImpedance 1 MOhmVoltage max. 30 DCAnalogue voltage input 0 ... 10 V / 2 ... 10 V DCAnalogue current input 0 ... 20 mA / 4 ... 20 mAMechanical specificationsConnection 7-pin screw terminal

max. core cross-section 0.34 ... 1.5 mm2

Mass approx. 50 g

1 2 3 4 5 6 7

max. 19.3

59 6.5

4

22 x

45

48

24

TerminalNo.1234567

10 ... 30 V DC0 V (GND)0 V LATCHLATCHCurrent input0 V input signalVoltage input

1 2 3 4 5 6 7

Wiring Diagrams

Dimensions

Terminal Connection

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 4: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1082 Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Spec

ial F

unct

ions

Dev

ices

• 2 adjustable limit values• 2 relay outputs• Operation via keypad• Programmable characteristics• Resetting the outputs, automatic, ma-

nual or with external signal• Connection via plug-in screw terminals• Auxiliary power output for sensors (On-

ly DA5-IU-2K-V)• Protection degree IP65 in accordance

with DIN EN 60529 (front only)• Shock resistance in accordance with

DIN EN 60068-2-27• Vibration resistance in accordance with

DIN EN 60068-2-6• System hum suppression

FunctionThe DA5-IU-2K-... permits a simple visualinspection by operating and maintenancepersonnel. It converts the analogue sensoroutput signal into a readable form for thispurpose. Depending on the task or setting,4 mA ... 20 mA or 0 % ... 100 % values canbe displayed.

Scope of delivery:• Process control unit DA5-IU-2K-...• Screw terminals

1 RM 5.08 8-pole terminal for power sup-ply and outputs1 RM 3.81 11-pole terminal for measuringand control inputs

• Clamp clip• Seal• 1 sheet of adhesive symbols

Dimensions

Electrical connection

DA5-IU-2K-C DA5-IU-2K-VGeneral specificationsPre-selection 2-foldData storage 106 storage cycles or 10 years, EEPROMProgramming keypad-driven menuIndicators/operating meansType 7-segment LED display, redNumber of decades 5Display value digit height 14.2 mmPre-selection digit height 14.2 mmDisplay interval -19999 ... 99999Decimal point freely adjustableResolution 14 BitScale factor via characteristic curve with up to 24 value pairsReset manually or externalKey interlock with "high"-level at terminal "KEY"Electrical specificationsOperating voltage 10 ... 30 V DC 90 ... 260 V ACPower consumption 2 W 7 VAOutputRelay 2 x 250 V AC/ 300 V DC, 3 A, changeo-

ver contact2 x 250 V AC/ 300 V DC, 3 A, changeo-

ver contactSensor supply - 24 V DC , 100 mAInputImpedance > 1 MΩ for voltage measurement

< 50 Ω for current measurementAnalogue voltage input 0 ... 10 V / 2 ... 10 V DC,

-10 ... 10 V DCAnalogue current input 0 ... 20 mA / 4 ... 20 mAMechanical specificationsConnection 8-pin and 11 pin connectors with plug-in screw terminalsMass 220 g

Control panel cutout

96

48

44.9

x91.

9

92+0.8

67.1 6.5

4

max. 19

45+

0.6

15.5

not assigned

on S1

Reset S1/8

Auxiliary power output(only on DA5-IU-2K-V)

Reference earth for reset S1/7

Key lock-out "Key" S1/6

Voltmeter input S1/3

Reference earth S1/2

Ammeter input S1/1

90 ... 260 V AC supply (...-V)10 ... 30 V DC 0 V DC (...-C) Connector S1/... Connector S2/...

Indicator

Relay 2

Relay 1

+24

V D

C,

0 V

DC

OUT 1 S2/3

4 5 10 S1/11

100

mA

S1/9

S2/2

S2/1OUT 2 S2/6

S2/5

S2/4

S2/7 S2/8

• 2 adjustable limit values• 2 relay outputs• Operation via keypad• Programmable characteristics• Resetting the outputs, automatic, ma-

nual or with external signal• Connection via plug-in screw terminals• Auxiliary power output for sensors (On-

ly DA5-IU-2K-V)• Protection degree IP65 in accordance

with DIN EN 60529 (front only)• Shock resistance in accordance with

DIN EN 60068-2-27• Vibration resistance in accordance with

DIN EN 60068-2-6• System hum suppression

FunctionThe DA5-IU-2K-... permits a simple visualinspection by operating and maintenancepersonnel. It converts the analogue sensoroutput signal into a readable form for thispurpose. Depending on the task or setting,4 mA ... 20 mA or 0 % ... 100 % values canbe displayed.

Scope of delivery:• Process control unit DA5-IU-2K-...• Screw terminals

1 RM 5.08 8-pole terminal for power sup-ply and outputs1 RM 3.81 11-pole terminal for measuringand control inputs

• Clamp clip• Seal• 1 sheet of adhesive symbols

Dimensions

Electrical connection

DA5-IU-2K-C DA5-IU-2K-VGeneral specificationsPre-selection 2-foldData storage 106 storage cycles or 10 years, EEPROMProgramming keypad-driven menuIndicators/operating meansType 7-segment LED display, redNumber of decades 5Display value digit height 14.2 mmPre-selection digit height 14.2 mmDisplay interval -19999 ... 99999Decimal point freely adjustableResolution 14 BitScale factor via characteristic curve with up to 24 value pairsReset manually or externalKey interlock with "high"-level at terminal "KEY"Electrical specificationsOperating voltage 10 ... 30 V DC 90 ... 260 V ACPower consumption 2 W 7 VAOutputRelay 2 x 250 V AC/ 300 V DC, 3 A, changeo-

ver contact2 x 250 V AC/ 300 V DC, 3 A, changeo-

ver contactSensor supply - 24 V DC , 100 mAInputImpedance > 1 MΩ for voltage measurement

< 50 Ω for current measurementAnalogue voltage input 0 ... 10 V / 2 ... 10 V DC,

-10 ... 10 V DCAnalogue current input 0 ... 20 mA / 4 ... 20 mAMechanical specificationsConnection 8-pin and 11 pin connectors with plug-in screw terminalsMass 220 g

Control panel cutout

96

48

44.9

x91.

9

92+0.8

67.1 6.5

4

max. 19

45+

0.6

15.5

not assigned

on S1

Reset S1/8

Auxiliary power output(only on DA5-IU-2K-V)

Reference earth for reset S1/7

Key lock-out "Key" S1/6

Voltmeter input S1/3

Reference earth S1/2

Ammeter input S1/1

90 ... 260 V AC supply (...-V)10 ... 30 V DC 0 V DC (...-C) Connector S1/... Connector S2/...

Indicator

Relay 2

Relay 1

+24

V D

C,

0 V

DC

OUT 1 S2/3

4 5 10 S1/11

100

mA

S1/9

S2/2

S2/1OUT 2 S2/6

S2/5

S2/4

S2/7 S2/8

Digital Display Meter

Technical Specifications

• 2 adjustable limit values• 2 relay outputs• Programmable characteristics• Resetting the outputs, automatic,

manual or with external signal• Auxiliary power output for sensors

(DA5-IU-2K-V)

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 5: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1083Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Special Functions Devices

• 2 adjustable limit values• 2 relay outputs• Operation via keypad• Programmable characteristics• Resetting the outputs, automatic, ma-

nual or with external signal• Connection via plug-in screw terminals• Auxiliary power output for sensors (On-

ly DA5-IU-2K-V)• Protection degree IP65 in accordance

with DIN EN 60529 (front only)• Shock resistance in accordance with

DIN EN 60068-2-27• Vibration resistance in accordance with

DIN EN 60068-2-6• System hum suppression

FunctionThe DA5-IU-2K-... permits a simple visualinspection by operating and maintenancepersonnel. It converts the analogue sensoroutput signal into a readable form for thispurpose. Depending on the task or setting,4 mA ... 20 mA or 0 % ... 100 % values canbe displayed.

Scope of delivery:• Process control unit DA5-IU-2K-...• Screw terminals

1 RM 5.08 8-pole terminal for power sup-ply and outputs1 RM 3.81 11-pole terminal for measuringand control inputs

• Clamp clip• Seal• 1 sheet of adhesive symbols

Dimensions

Electrical connection

DA5-IU-2K-C DA5-IU-2K-VGeneral specificationsPre-selection 2-foldData storage 106 storage cycles or 10 years, EEPROMProgramming keypad-driven menuIndicators/operating meansType 7-segment LED display, redNumber of decades 5Display value digit height 14.2 mmPre-selection digit height 14.2 mmDisplay interval -19999 ... 99999Decimal point freely adjustableResolution 14 BitScale factor via characteristic curve with up to 24 value pairsReset manually or externalKey interlock with "high"-level at terminal "KEY"Electrical specificationsOperating voltage 10 ... 30 V DC 90 ... 260 V ACPower consumption 2 W 7 VAOutputRelay 2 x 250 V AC/ 300 V DC, 3 A, changeo-

ver contact2 x 250 V AC/ 300 V DC, 3 A, changeo-

ver contactSensor supply - 24 V DC , 100 mAInputImpedance > 1 MΩ for voltage measurement

< 50 Ω for current measurementAnalogue voltage input 0 ... 10 V / 2 ... 10 V DC,

-10 ... 10 V DCAnalogue current input 0 ... 20 mA / 4 ... 20 mAMechanical specificationsConnection 8-pin and 11 pin connectors with plug-in screw terminalsMass 220 g

Control panel cutout

96

48

44.9

x91.

9

92+0.8

67.1 6.5

4

max. 19

45+

0.6

15.5

not assigned

on S1

Reset S1/8

Auxiliary power output(only on DA5-IU-2K-V)

Reference earth for reset S1/7

Key lock-out "Key" S1/6

Voltmeter input S1/3

Reference earth S1/2

Ammeter input S1/1

90 ... 260 V AC supply (...-V)10 ... 30 V DC 0 V DC (...-C) Connector S1/... Connector S2/...

Indicator

Relay 2

Relay 1

+24

V D

C,

0 V

DC

OUT 1 S2/3

4 5 10 S1/11

100

mA

S1/9

S2/2

S2/1OUT 2 S2/6

S2/5

S2/4

S2/7 S2/8

• 2 adjustable limit values• 2 relay outputs• Operation via keypad• Programmable characteristics• Resetting the outputs, automatic, ma-

nual or with external signal• Connection via plug-in screw terminals• Auxiliary power output for sensors (On-

ly DA5-IU-2K-V)• Protection degree IP65 in accordance

with DIN EN 60529 (front only)• Shock resistance in accordance with

DIN EN 60068-2-27• Vibration resistance in accordance with

DIN EN 60068-2-6• System hum suppression

FunctionThe DA5-IU-2K-... permits a simple visualinspection by operating and maintenancepersonnel. It converts the analogue sensoroutput signal into a readable form for thispurpose. Depending on the task or setting,4 mA ... 20 mA or 0 % ... 100 % values canbe displayed.

Scope of delivery:• Process control unit DA5-IU-2K-...• Screw terminals

1 RM 5.08 8-pole terminal for power sup-ply and outputs1 RM 3.81 11-pole terminal for measuringand control inputs

• Clamp clip• Seal• 1 sheet of adhesive symbols

Dimensions

Electrical connection

DA5-IU-2K-C DA5-IU-2K-VGeneral specificationsPre-selection 2-foldData storage 106 storage cycles or 10 years, EEPROMProgramming keypad-driven menuIndicators/operating meansType 7-segment LED display, redNumber of decades 5Display value digit height 14.2 mmPre-selection digit height 14.2 mmDisplay interval -19999 ... 99999Decimal point freely adjustableResolution 14 BitScale factor via characteristic curve with up to 24 value pairsReset manually or externalKey interlock with "high"-level at terminal "KEY"Electrical specificationsOperating voltage 10 ... 30 V DC 90 ... 260 V ACPower consumption 2 W 7 VAOutputRelay 2 x 250 V AC/ 300 V DC, 3 A, changeo-

ver contact2 x 250 V AC/ 300 V DC, 3 A, changeo-

ver contactSensor supply - 24 V DC , 100 mAInputImpedance > 1 MΩ for voltage measurement

< 50 Ω for current measurementAnalogue voltage input 0 ... 10 V / 2 ... 10 V DC,

-10 ... 10 V DCAnalogue current input 0 ... 20 mA / 4 ... 20 mAMechanical specificationsConnection 8-pin and 11 pin connectors with plug-in screw terminalsMass 220 g

Control panel cutout

96

48

44.9

x91.

9

92+0.8

67.1 6.5

4

max. 19

45+

0.6

15.5

not assigned

on S1

Reset S1/8

Auxiliary power output(only on DA5-IU-2K-V)

Reference earth for reset S1/7

Key lock-out "Key" S1/6

Voltmeter input S1/3

Reference earth S1/2

Ammeter input S1/1

90 ... 260 V AC supply (...-V)10 ... 30 V DC 0 V DC (...-C) Connector S1/... Connector S2/...

Indicator

Relay 2

Relay 1

+24

V D

C,

0 V

DC

OUT 1 S2/3

4 5 10 S1/11

100

mA

S1/9

S2/2

S2/1OUT 2 S2/6

S2/5

S2/4

S2/7 S2/8

Wiring Diagrams

Dimensions

Terminal Connection

DA5-14-2K-C90 ...260 VAC

S2/7 VAC (N2)S2/8 VAC (L2)

DA5-14-2K-C10 ...30 VDC

S2/7 +VDCS2/8 GND

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 6: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1084 Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Spec

ial F

unct

ions

Dev

ices

• Counter/Timer/Tachometer• Counter frequency up to 20 kHz• LED indicator, red• 6 decade devices• Operation via keypad• Two counter inputs• Fixing with plug-in frame for easy instal-

lation• Connection via screw terminals• Manual or external reset• PNP and NPN sensors can be connec-

ted• Protection degree IP65 in accordance

with DIN EN 60529 (front only)• Shock resistance in accordance with

DIN EN 60068-2-27• Vibration resistance in accordance with

DIN EN 60068-2-6

Dimensions

Electrical connection

KCT-6S-C KCT-6ST-CGeneral specificationsPre-selection - singleProgramming keypad-driven menu keypad-driven menuIndicators/operating meansType 7-segment LED display, red 7-segment LED display, redNumber of decades 6 6Display value digit height 8 mm digit height 8 mmPre-selection - active at counter value ≤ 0Display interval -199999 ... 999999 with suppression of

leading zeros-199999 ... 999999 with suppression of

leading zerosDecimal point 0 to max 3 fractional digits 0 to max 3 fractional digitsScale factor 0.0001 ... 99.9999 0.0001 ... 99.9999Reset manually or external manually or externalKey interlock - -Electrical specificationsOperating voltage 10 ... 30 V DCPower consumption 1.5 WInputCounting frequency 30 Hz / 20 kHzImpedance 10 kOhmVoltage low: 0 V DC ... 0.2 x supply voltage; high: 0.6 x supply voltage ... 30 V DCCounting method adding or subtractingOutputOptocoupler - Semiconductor output 30 V, max. 10 mAMechanical specificationsConnection 5-pin screw terminal ,

max. core cross-section 0.34 ... 1.5 mm27-pin screw terminal ,

max. core cross-section 0.34 ... 1.5 mm2

Mass 48 g 48 g

1 2 3 4 5 6 71 2 3 4 5

KCT-6S-C KCT-6ST-C

max. 19.3

59 6.5

4

22 x

45

48

24

4

5

3

2

6

7

1

Input B

Reset

Input A

10 ... 30 V DC

GND

Counting devicewith display

Polarity control

Optocoupler output(only KCT-6ST-C)

Counter / Timer / Tachometer

Technical Specifications

• Counter frequency up to 20 kHz• LED indicator, red• 6 decade devices• Operation via keypad• Two counter inputs• Manual or external reset• PNP and NPN sensors can

be connected

• Counter/Timer/Tachometer• Counter frequency up to 20 kHz• LED indicator, red• 6 decade devices• Operation via keypad• Two counter inputs• Fixing with plug-in frame for easy instal-

lation• Connection via screw terminals• Manual or external reset• PNP and NPN sensors can be connec-

ted• Protection degree IP65 in accordance

with DIN EN 60529 (front only)• Shock resistance in accordance with

DIN EN 60068-2-27• Vibration resistance in accordance with

DIN EN 60068-2-6

Dimensions

Electrical connection

KCT-6S-C KCT-6ST-CGeneral specificationsPre-selection - singleProgramming keypad-driven menu keypad-driven menuIndicators/operating meansType 7-segment LED display, red 7-segment LED display, redNumber of decades 6 6Display value digit height 8 mm digit height 8 mmPre-selection - active at counter value ≤ 0Display interval -199999 ... 999999 with suppression of

leading zeros-199999 ... 999999 with suppression of

leading zerosDecimal point 0 to max 3 fractional digits 0 to max 3 fractional digitsScale factor 0.0001 ... 99.9999 0.0001 ... 99.9999Reset manually or external manually or externalKey interlock - -Electrical specificationsOperating voltage 10 ... 30 V DCPower consumption 1.5 WInputCounting frequency 30 Hz / 20 kHzImpedance 10 kOhmVoltage low: 0 V DC ... 0.2 x supply voltage; high: 0.6 x supply voltage ... 30 V DCCounting method adding or subtractingOutputOptocoupler - Semiconductor output 30 V, max. 10 mAMechanical specificationsConnection 5-pin screw terminal ,

max. core cross-section 0.34 ... 1.5 mm27-pin screw terminal ,

max. core cross-section 0.34 ... 1.5 mm2

Mass 48 g 48 g

1 2 3 4 5 6 71 2 3 4 5

KCT-6S-C KCT-6ST-C

max. 19.3

59 6.5

4

22 x

45

48

24

4

5

3

2

6

7

1

Input B

Reset

Input A

10 ... 30 V DC

GND

Counting devicewith display

Polarity control

Optocoupler output(only KCT-6ST-C)

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 7: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1085Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Special Functions Devices

Wiring Diagrams

Dimensions

• Counter/Timer/Tachometer• Counter frequency up to 20 kHz• LED indicator, red• 6 decade devices• Operation via keypad• Two counter inputs• Fixing with plug-in frame for easy instal-

lation• Connection via screw terminals• Manual or external reset• PNP and NPN sensors can be connec-

ted• Protection degree IP65 in accordance

with DIN EN 60529 (front only)• Shock resistance in accordance with

DIN EN 60068-2-27• Vibration resistance in accordance with

DIN EN 60068-2-6

Dimensions

Electrical connection

KCT-6S-C KCT-6ST-CGeneral specificationsPre-selection - singleProgramming keypad-driven menu keypad-driven menuIndicators/operating meansType 7-segment LED display, red 7-segment LED display, redNumber of decades 6 6Display value digit height 8 mm digit height 8 mmPre-selection - active at counter value ≤ 0Display interval -199999 ... 999999 with suppression of

leading zeros-199999 ... 999999 with suppression of

leading zerosDecimal point 0 to max 3 fractional digits 0 to max 3 fractional digitsScale factor 0.0001 ... 99.9999 0.0001 ... 99.9999Reset manually or external manually or externalKey interlock - -Electrical specificationsOperating voltage 10 ... 30 V DCPower consumption 1.5 WInputCounting frequency 30 Hz / 20 kHzImpedance 10 kOhmVoltage low: 0 V DC ... 0.2 x supply voltage; high: 0.6 x supply voltage ... 30 V DCCounting method adding or subtractingOutputOptocoupler - Semiconductor output 30 V, max. 10 mAMechanical specificationsConnection 5-pin screw terminal ,

max. core cross-section 0.34 ... 1.5 mm27-pin screw terminal ,

max. core cross-section 0.34 ... 1.5 mm2

Mass 48 g 48 g

1 2 3 4 5 6 71 2 3 4 5

KCT-6S-C KCT-6ST-C

max. 19.3

59 6.5

4

22 x

45

48

24

4

5

3

2

6

7

1

Input B

Reset

Input A

10 ... 30 V DC

GND

Counting devicewith display

Polarity control

Optocoupler output(only KCT-6ST-C)

• Counter/Timer/Tachometer• Counter frequency up to 20 kHz• LED indicator, red• 6 decade devices• Operation via keypad• Two counter inputs• Fixing with plug-in frame for easy instal-

lation• Connection via screw terminals• Manual or external reset• PNP and NPN sensors can be connec-

ted• Protection degree IP65 in accordance

with DIN EN 60529 (front only)• Shock resistance in accordance with

DIN EN 60068-2-27• Vibration resistance in accordance with

DIN EN 60068-2-6

Dimensions

Electrical connection

KCT-6S-C KCT-6ST-CGeneral specificationsPre-selection - singleProgramming keypad-driven menu keypad-driven menuIndicators/operating meansType 7-segment LED display, red 7-segment LED display, redNumber of decades 6 6Display value digit height 8 mm digit height 8 mmPre-selection - active at counter value ≤ 0Display interval -199999 ... 999999 with suppression of

leading zeros-199999 ... 999999 with suppression of

leading zerosDecimal point 0 to max 3 fractional digits 0 to max 3 fractional digitsScale factor 0.0001 ... 99.9999 0.0001 ... 99.9999Reset manually or external manually or externalKey interlock - -Electrical specificationsOperating voltage 10 ... 30 V DCPower consumption 1.5 WInputCounting frequency 30 Hz / 20 kHzImpedance 10 kOhmVoltage low: 0 V DC ... 0.2 x supply voltage; high: 0.6 x supply voltage ... 30 V DCCounting method adding or subtractingOutputOptocoupler - Semiconductor output 30 V, max. 10 mAMechanical specificationsConnection 5-pin screw terminal ,

max. core cross-section 0.34 ... 1.5 mm27-pin screw terminal ,

max. core cross-section 0.34 ... 1.5 mm2

Mass 48 g 48 g

1 2 3 4 5 6 71 2 3 4 5

KCT-6S-C KCT-6ST-C

max. 19.3

59 6.5

4

22 x

45

48

24

4

5

3

2

6

7

1

Input B

Reset

Input A

10 ... 30 V DC

GND

Counting devicewith display

Polarity control

Optocoupler output(only KCT-6ST-C)

Terminal Connection

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 8: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1086 Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Spec

ial F

unct

ions

Dev

ices

• Counter/Timer/Tachometer• Counter frequency up to 20 kHz• 6-digit LED indicator, red• 1 Pre-selection• Status LED indication for output an pre-

selection value• Display range and preselection range

from -199999 up to 999999Overflow will be evaluated correctly up to 1 decade

• Programmable functionality as pulse counter, frequency counter, timer or

• Relay output• Adding/subtracting via 2 separate in-

puts• PNP and NPN sensors can be connec-

ted• Protection degree IP65 (front only)

Dimensions

Electrical connection

KCT1-6SR-C KCT1-6SR-VGeneral specificationsPre-selection singleProgramming keypad-driven menuIndicators/operating meansType 7-segment LED display, redNumber of decades 6Display value digit height 8 mmPre-selection switchableDisplay interval -99999 ... 999999Decimal point 0 to max 3 fractional digitsScale factor 0.0001 ... 99.9999Reset manually or externalKey interlock with "high"-level at terminal "KEY"Electrical specificationsOperating voltage 10 ... 30 V DC 90 ... 250 V ACPower consumption max. 1.2 VA max. 7 VAInputCounting frequency 20 kHz 20 kHzImpedance approx. 10 kOhm approx. 10 kOhmVoltage low: 0 ... 0.2 x Ue

high: 0.6 x Ue ... 30 V DClow: 0 ... 4 V DC

high: 12 ... 30 V DC

Counting method adding or subtracting adding or subtractingOutputRelay 250 V AC, 0.3 ... 3 mA, changeover con-

tact250 V AC, 0.3 ... 3 mA, changeover con-

tactSensor supply - 14.4 ... 28 V DC, 100 mAMechanical specificationsConnection 2 plug-in 7-pin screw terminals

max. core cross-section 0.34 ... 1.5 mm2

Mass approx. 200 g

15.5

80.1

9.3

7.3

max. 10.5

4548

48

3 71 4 5 62

3 71 4 5 62

31 4 52

Connector assignment X1supply voltage and outputs

TerminalNo.123

4

5

6

7

AC version

n.c.n.c.output relay common contact (C)output relay normally open contact (NO)output relay normally closed contact (NC)supply voltage90 ... 250 V ACsupply voltage90 ... 250 V AC

10 ... 30 V DC version

operating voltage10 ... 30 V DC0 V DC (GND)

TerminalNo.45

AC and DC versions

Relay normally closed (NC)Relay normally open (NO)

TerminalNo.1

2

34567

AC version

SensorSupply voltageReference voltage

Counter input ACounter input BReset inputGate circuitInput for key locking

10 ... 30 V DC versionnot connectednot connected

Name

+24 VDC

0 VDC(GND)INP AINP BRESETGATEKEY

Connector assignment X2inputs

AttentionIn the case of selection of and (inverted relay function) the function of terminals 4 and 5 are changed:

3 71 4 5 62

3 71 4 5 62X2

X1

Counter / Timer / Tachometer

Technical Specifications

• Counter frequency up to 20 kHz• 6-digit LED indicator, red• 1 pre-selection• Status LED indication for output and

preselection value• Programmable functionality as pulse

counter, frequency counter, timer or • Relay output• Adding/subtracting via 2 separate inputs• PNP and NPN sensors can be connected

• Counter/Timer/Tachometer• Counter frequency up to 20 kHz• 6-digit LED indicator, red• 1 Pre-selection• Status LED indication for output an pre-

selection value• Display range and preselection range

from -199999 up to 999999Overflow will be evaluated correctly up to 1 decade

• Programmable functionality as pulse counter, frequency counter, timer or

• Relay output• Adding/subtracting via 2 separate in-

puts• PNP and NPN sensors can be connec-

ted• Protection degree IP65 (front only)

Dimensions

Electrical connection

KCT1-6SR-C KCT1-6SR-VGeneral specificationsPre-selection singleProgramming keypad-driven menuIndicators/operating meansType 7-segment LED display, redNumber of decades 6Display value digit height 8 mmPre-selection switchableDisplay interval -99999 ... 999999Decimal point 0 to max 3 fractional digitsScale factor 0.0001 ... 99.9999Reset manually or externalKey interlock with "high"-level at terminal "KEY"Electrical specificationsOperating voltage 10 ... 30 V DC 90 ... 250 V ACPower consumption max. 1.2 VA max. 7 VAInputCounting frequency 20 kHz 20 kHzImpedance approx. 10 kOhm approx. 10 kOhmVoltage low: 0 ... 0.2 x Ue

high: 0.6 x Ue ... 30 V DClow: 0 ... 4 V DC

high: 12 ... 30 V DC

Counting method adding or subtracting adding or subtractingOutputRelay 250 V AC, 0.3 ... 3 mA, changeover con-

tact250 V AC, 0.3 ... 3 mA, changeover con-

tactSensor supply - 14.4 ... 28 V DC, 100 mAMechanical specificationsConnection 2 plug-in 7-pin screw terminals

max. core cross-section 0.34 ... 1.5 mm2

Mass approx. 200 g

15.5

80.1

9.3

7.3

max. 10.5

4548

48

3 71 4 5 62

3 71 4 5 62

31 4 52

Connector assignment X1supply voltage and outputs

TerminalNo.123

4

5

6

7

AC version

n.c.n.c.output relay common contact (C)output relay normally open contact (NO)output relay normally closed contact (NC)supply voltage90 ... 250 V ACsupply voltage90 ... 250 V AC

10 ... 30 V DC version

operating voltage10 ... 30 V DC0 V DC (GND)

TerminalNo.45

AC and DC versions

Relay normally closed (NC)Relay normally open (NO)

TerminalNo.1

2

34567

AC version

SensorSupply voltageReference voltage

Counter input ACounter input BReset inputGate circuitInput for key locking

10 ... 30 V DC versionnot connectednot connected

Name

+24 VDC

0 VDC(GND)INP AINP BRESETGATEKEY

Connector assignment X2inputs

AttentionIn the case of selection of and (inverted relay function) the function of terminals 4 and 5 are changed:

3 71 4 5 62

3 71 4 5 62X2

X1

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 9: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1087Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Special Functions Devices

• Counter/Timer/Tachometer• Counter frequency up to 20 kHz• 6-digit LED indicator, red• 1 Pre-selection• Status LED indication for output an pre-

selection value• Display range and preselection range

from -199999 up to 999999Overflow will be evaluated correctly up to 1 decade

• Programmable functionality as pulse counter, frequency counter, timer or

• Relay output• Adding/subtracting via 2 separate in-

puts• PNP and NPN sensors can be connec-

ted• Protection degree IP65 (front only)

Dimensions

Electrical connection

KCT1-6SR-C KCT1-6SR-VGeneral specificationsPre-selection singleProgramming keypad-driven menuIndicators/operating meansType 7-segment LED display, redNumber of decades 6Display value digit height 8 mmPre-selection switchableDisplay interval -99999 ... 999999Decimal point 0 to max 3 fractional digitsScale factor 0.0001 ... 99.9999Reset manually or externalKey interlock with "high"-level at terminal "KEY"Electrical specificationsOperating voltage 10 ... 30 V DC 90 ... 250 V ACPower consumption max. 1.2 VA max. 7 VAInputCounting frequency 20 kHz 20 kHzImpedance approx. 10 kOhm approx. 10 kOhmVoltage low: 0 ... 0.2 x Ue

high: 0.6 x Ue ... 30 V DClow: 0 ... 4 V DC

high: 12 ... 30 V DC

Counting method adding or subtracting adding or subtractingOutputRelay 250 V AC, 0.3 ... 3 mA, changeover con-

tact250 V AC, 0.3 ... 3 mA, changeover con-

tactSensor supply - 14.4 ... 28 V DC, 100 mAMechanical specificationsConnection 2 plug-in 7-pin screw terminals

max. core cross-section 0.34 ... 1.5 mm2

Mass approx. 200 g

15.5

80.1

9.3

7.3

max. 10.5

4548

48

3 71 4 5 62

3 71 4 5 62

31 4 52

Connector assignment X1supply voltage and outputs

TerminalNo.123

4

5

6

7

AC version

n.c.n.c.output relay common contact (C)output relay normally open contact (NO)output relay normally closed contact (NC)supply voltage90 ... 250 V ACsupply voltage90 ... 250 V AC

10 ... 30 V DC version

operating voltage10 ... 30 V DC0 V DC (GND)

TerminalNo.45

AC and DC versions

Relay normally closed (NC)Relay normally open (NO)

TerminalNo.1

2

34567

AC version

SensorSupply voltageReference voltage

Counter input ACounter input BReset inputGate circuitInput for key locking

10 ... 30 V DC versionnot connectednot connected

Name

+24 VDC

0 VDC(GND)INP AINP BRESETGATEKEY

Connector assignment X2inputs

AttentionIn the case of selection of and (inverted relay function) the function of terminals 4 and 5 are changed:

3 71 4 5 62

3 71 4 5 62X2

X1

Wiring Diagrams

Dimensions

• Counter/Timer/Tachometer• Counter frequency up to 20 kHz• 6-digit LED indicator, red• 1 Pre-selection• Status LED indication for output an pre-

selection value• Display range and preselection range

from -199999 up to 999999Overflow will be evaluated correctly up to 1 decade

• Programmable functionality as pulse counter, frequency counter, timer or

• Relay output• Adding/subtracting via 2 separate in-

puts• PNP and NPN sensors can be connec-

ted• Protection degree IP65 (front only)

Dimensions

Electrical connection

KCT1-6SR-C KCT1-6SR-VGeneral specificationsPre-selection singleProgramming keypad-driven menuIndicators/operating meansType 7-segment LED display, redNumber of decades 6Display value digit height 8 mmPre-selection switchableDisplay interval -99999 ... 999999Decimal point 0 to max 3 fractional digitsScale factor 0.0001 ... 99.9999Reset manually or externalKey interlock with "high"-level at terminal "KEY"Electrical specificationsOperating voltage 10 ... 30 V DC 90 ... 250 V ACPower consumption max. 1.2 VA max. 7 VAInputCounting frequency 20 kHz 20 kHzImpedance approx. 10 kOhm approx. 10 kOhmVoltage low: 0 ... 0.2 x Ue

high: 0.6 x Ue ... 30 V DClow: 0 ... 4 V DC

high: 12 ... 30 V DC

Counting method adding or subtracting adding or subtractingOutputRelay 250 V AC, 0.3 ... 3 mA, changeover con-

tact250 V AC, 0.3 ... 3 mA, changeover con-

tactSensor supply - 14.4 ... 28 V DC, 100 mAMechanical specificationsConnection 2 plug-in 7-pin screw terminals

max. core cross-section 0.34 ... 1.5 mm2

Mass approx. 200 g

15.5

80.1

9.3

7.3

max. 10.5

4548

48

3 71 4 5 62

3 71 4 5 62

31 4 52

Connector assignment X1supply voltage and outputs

TerminalNo.123

4

5

6

7

AC version

n.c.n.c.output relay common contact (C)output relay normally open contact (NO)output relay normally closed contact (NC)supply voltage90 ... 250 V ACsupply voltage90 ... 250 V AC

10 ... 30 V DC version

operating voltage10 ... 30 V DC0 V DC (GND)

TerminalNo.45

AC and DC versions

Relay normally closed (NC)Relay normally open (NO)

TerminalNo.1

2

34567

AC version

SensorSupply voltageReference voltage

Counter input ACounter input BReset inputGate circuitInput for key locking

10 ... 30 V DC versionnot connectednot connected

Name

+24 VDC

0 VDC(GND)INP AINP BRESETGATEKEY

Connector assignment X2inputs

AttentionIn the case of selection of and (inverted relay function) the function of terminals 4 and 5 are changed:

3 71 4 5 62

3 71 4 5 62X2

X1

Terminal Connection

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 10: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1088 Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Spec

ial F

unct

ions

Dev

ices

• Counter/Timer/Tachometer• 6-digit LED indicator, red• 2 independent pre-select values• RS 232 interface for parameter assign-

ment• Status LED indication for output an pre-

selection value• Display range and preselection range

from -199999 up to 999999Overflow will be evaluated correctly up to 1 decade

• Programmable functionality as pulse counter, frequency counter, timer or

• Relay output• Adding/subtracting via 2 separate in-

puts• PNP and NPN sensors can be connec-

ted• Protection degree IP65 (front only)

Dimensions

Electrical connection

KCT1-6WR/RS232-VGeneral specificationsPre-selection 2-foldProgramming keypad-driven menuIndicators/operating meansType 7-segment LED display, redNumber of decades 6Display value digit height 8 mmPre-selection switchableDisplay interval -999999 ... 999999Decimal point 0 to max 3 fractional digitsScale factor 0.0001 ... 99.9999Reset manually or externalKey interlock with "high"-level at terminal "KEY"Electrical specificationsOperating voltage 90 ... 250 V ACPower consumption max. 7 VAInputInterface RS 232 interface for parameter assignmentCounting frequency 20 kHzImpedance approx. 10 kOhmVoltage low: 0 ... 4 V DC

high: 12 ... 30 V DCCounting method adding or subtractingOutputRelay 250 V AC, 0.3 ... 3 A, 1 changeover contact, 1 normally-openSensor supply 14.4 ... 28 V DC, 100 mAMechanical specificationsConnection 2 plug-in 7-pin screw terminalsMass approx. 200 g

15.5

80.1

9.3

7.3

max. 10.5

4548

48

3 71 4 5 62

3 71 4 5 62

31 4 52

Connection assignment X1Supply voltage and outputs

TerminalNo.123

4

5

6

7

AC version

Output 1 relay contactOutput 1 relay contactOutput 2relay common contact (C)Output 2 relaynormally open contact (NO)Output 2 relaynormally closed contact (NC)Power supply90 ... 250 V ACPower supply90 ... 250 V AC

TerminalNo.45

AC version

Relay normally closed contact (NC)Relay normally open contact (NO)

TerminalNo.12

34567

AC version

Sensor supply voltageReference voltage

Counter input ACounter input BReset inputGate inputInput of push-button lock

Name

+24 V DC0 VDC(GND)INP AINP BRESETGATEKEY

Connection assignment X2Inputs

Connection assignment X3Serial interface

AttentionIn the case of selection of and (inverted relay control) the connections of terminals 4 and 5 are changed:

3 71 4 5 62

3 71 4 5 62X2

X1

31 4 52

X3

• Counter/Timer/Tachometer• 6-digit LED indicator, red• 2 independent pre-select values• RS 232 interface for parameter assign-

ment• Status LED indication for output an pre-

selection value• Display range and preselection range

from -199999 up to 999999Overflow will be evaluated correctly up to 1 decade

• Programmable functionality as pulse counter, frequency counter, timer or

• Relay output• Adding/subtracting via 2 separate in-

puts• PNP and NPN sensors can be connec-

ted• Protection degree IP65 (front only)

Dimensions

Electrical connection

KCT1-6WR/RS232-VGeneral specificationsPre-selection 2-foldProgramming keypad-driven menuIndicators/operating meansType 7-segment LED display, redNumber of decades 6Display value digit height 8 mmPre-selection switchableDisplay interval -999999 ... 999999Decimal point 0 to max 3 fractional digitsScale factor 0.0001 ... 99.9999Reset manually or externalKey interlock with "high"-level at terminal "KEY"Electrical specificationsOperating voltage 90 ... 250 V ACPower consumption max. 7 VAInputInterface RS 232 interface for parameter assignmentCounting frequency 20 kHzImpedance approx. 10 kOhmVoltage low: 0 ... 4 V DC

high: 12 ... 30 V DCCounting method adding or subtractingOutputRelay 250 V AC, 0.3 ... 3 A, 1 changeover contact, 1 normally-openSensor supply 14.4 ... 28 V DC, 100 mAMechanical specificationsConnection 2 plug-in 7-pin screw terminalsMass approx. 200 g

15.5

80.1

9.3

7.3

max. 10.5

4548

48

3 71 4 5 62

3 71 4 5 62

31 4 52

Connection assignment X1Supply voltage and outputs

TerminalNo.123

4

5

6

7

AC version

Output 1 relay contactOutput 1 relay contactOutput 2relay common contact (C)Output 2 relaynormally open contact (NO)Output 2 relaynormally closed contact (NC)Power supply90 ... 250 V ACPower supply90 ... 250 V AC

TerminalNo.45

AC version

Relay normally closed contact (NC)Relay normally open contact (NO)

TerminalNo.12

34567

AC version

Sensor supply voltageReference voltage

Counter input ACounter input BReset inputGate inputInput of push-button lock

Name

+24 V DC0 VDC(GND)INP AINP BRESETGATEKEY

Connection assignment X2Inputs

Connection assignment X3Serial interface

AttentionIn the case of selection of and (inverted relay control) the connections of terminals 4 and 5 are changed:

3 71 4 5 62

3 71 4 5 62X2

X1

31 4 52

X3

Counter / Timer / Tachometer

Technical Specifications

• 6-digit LED indicator, red• 2 independent pre-select values• RS232 interface for parameter assignment• Status LED indication for output an

preselection value• Programmable functionality as pulse

counter, frequency counter, timer or • Relay output• Adding/subtracting via 2 separate inputs• PNP and NPN sensors can be connected

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 11: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1089Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Special Functions Devices

Wiring Diagrams

Dimensions

• Counter/Timer/Tachometer• 6-digit LED indicator, red• 2 independent pre-select values• RS 232 interface for parameter assign-

ment• Status LED indication for output an pre-

selection value• Display range and preselection range

from -199999 up to 999999Overflow will be evaluated correctly up to 1 decade

• Programmable functionality as pulse counter, frequency counter, timer or

• Relay output• Adding/subtracting via 2 separate in-

puts• PNP and NPN sensors can be connec-

ted• Protection degree IP65 (front only)

Dimensions

Electrical connection

KCT1-6WR/RS232-VGeneral specificationsPre-selection 2-foldProgramming keypad-driven menuIndicators/operating meansType 7-segment LED display, redNumber of decades 6Display value digit height 8 mmPre-selection switchableDisplay interval -999999 ... 999999Decimal point 0 to max 3 fractional digitsScale factor 0.0001 ... 99.9999Reset manually or externalKey interlock with "high"-level at terminal "KEY"Electrical specificationsOperating voltage 90 ... 250 V ACPower consumption max. 7 VAInputInterface RS 232 interface for parameter assignmentCounting frequency 20 kHzImpedance approx. 10 kOhmVoltage low: 0 ... 4 V DC

high: 12 ... 30 V DCCounting method adding or subtractingOutputRelay 250 V AC, 0.3 ... 3 A, 1 changeover contact, 1 normally-openSensor supply 14.4 ... 28 V DC, 100 mAMechanical specificationsConnection 2 plug-in 7-pin screw terminalsMass approx. 200 g

15.5

80.1

9.3

7.3

max. 10.5

4548

48

3 71 4 5 62

3 71 4 5 62

31 4 52

Connection assignment X1Supply voltage and outputs

TerminalNo.123

4

5

6

7

AC version

Output 1 relay contactOutput 1 relay contactOutput 2relay common contact (C)Output 2 relaynormally open contact (NO)Output 2 relaynormally closed contact (NC)Power supply90 ... 250 V ACPower supply90 ... 250 V AC

TerminalNo.45

AC version

Relay normally closed contact (NC)Relay normally open contact (NO)

TerminalNo.12

34567

AC version

Sensor supply voltageReference voltage

Counter input ACounter input BReset inputGate inputInput of push-button lock

Name

+24 V DC0 VDC(GND)INP AINP BRESETGATEKEY

Connection assignment X2Inputs

Connection assignment X3Serial interface

AttentionIn the case of selection of and (inverted relay control) the connections of terminals 4 and 5 are changed:

3 71 4 5 62

3 71 4 5 62X2

X1

31 4 52

X3

• Counter/Timer/Tachometer• 6-digit LED indicator, red• 2 independent pre-select values• RS 232 interface for parameter assign-

ment• Status LED indication for output an pre-

selection value• Display range and preselection range

from -199999 up to 999999Overflow will be evaluated correctly up to 1 decade

• Programmable functionality as pulse counter, frequency counter, timer or

• Relay output• Adding/subtracting via 2 separate in-

puts• PNP and NPN sensors can be connec-

ted• Protection degree IP65 (front only)

Dimensions

Electrical connection

KCT1-6WR/RS232-VGeneral specificationsPre-selection 2-foldProgramming keypad-driven menuIndicators/operating meansType 7-segment LED display, redNumber of decades 6Display value digit height 8 mmPre-selection switchableDisplay interval -999999 ... 999999Decimal point 0 to max 3 fractional digitsScale factor 0.0001 ... 99.9999Reset manually or externalKey interlock with "high"-level at terminal "KEY"Electrical specificationsOperating voltage 90 ... 250 V ACPower consumption max. 7 VAInputInterface RS 232 interface for parameter assignmentCounting frequency 20 kHzImpedance approx. 10 kOhmVoltage low: 0 ... 4 V DC

high: 12 ... 30 V DCCounting method adding or subtractingOutputRelay 250 V AC, 0.3 ... 3 A, 1 changeover contact, 1 normally-openSensor supply 14.4 ... 28 V DC, 100 mAMechanical specificationsConnection 2 plug-in 7-pin screw terminalsMass approx. 200 g

15.5

80.1

9.3

7.3

max. 10.5

4548

48

3 71 4 5 62

3 71 4 5 62

31 4 52

Connection assignment X1Supply voltage and outputs

TerminalNo.123

4

5

6

7

AC version

Output 1 relay contactOutput 1 relay contactOutput 2relay common contact (C)Output 2 relaynormally open contact (NO)Output 2 relaynormally closed contact (NC)Power supply90 ... 250 V ACPower supply90 ... 250 V AC

TerminalNo.45

AC version

Relay normally closed contact (NC)Relay normally open contact (NO)

TerminalNo.12

34567

AC version

Sensor supply voltageReference voltage

Counter input ACounter input BReset inputGate inputInput of push-button lock

Name

+24 V DC0 VDC(GND)INP AINP BRESETGATEKEY

Connection assignment X2Inputs

Connection assignment X3Serial interface

AttentionIn the case of selection of and (inverted relay control) the connections of terminals 4 and 5 are changed:

3 71 4 5 62

3 71 4 5 62X2

X1

31 4 52

X3

Terminal Connection

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 12: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1090 Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Spec

ial F

unct

ions

Dev

ices

• Counter/Timer/Tachometer• Extremely bright, large LED indicator• 1 pre-select value with transistor output• PNP and NPN sensors can be connec-

ted• Adding/subtracting via 2 separate in-

puts• Protection degree IP65 (front only)

Dimensions

Electrical connection

KCT2-6ST-VGeneral specificationsPre-selection singleProgramming keypad-driven menuIndicators/operating meansType 7-segment LED display, redNumber of decades 6Display value digit height 14 mmPre-selection active at counter value ≤ 0Display interval -199999 ... 999999 with suppression of leading zerosDecimal point 0 to max 3 fractional digitsScale factor 0.0001 ... 99.9999Reset manually or externalKey interlock -Electrical specificationsOperating voltage 90 ... 260 V ACPower consumption max. 6 VAInputCounting frequency 30 Hz / 20 kHz (max. 11 kHz when counting with phase discriminator)Impedance 10 kOhmVoltage low: 0 ... 4 V DC ; high: 12 ... 30 V DCCounting method adding or subtractingOutputSensor supply 24 V DC ± 15 % / 100 mAOptocoupler NPN, offener Kollektor und offener Emitter

30 V / 15 mAMechanical specificationsConnection 2-pin and 7-pin plug-in connection terminals, core cross-section ≤ 1.5 mm2

Mass approx. 150 g

Control panel cutout

96

48

44.9

x91.

9

92+0.8

67.1 6.5

4

max. 19

45+

0.6

12

Connection assignment X2

Terminal No. 1 2

AC version

Power supply90 ... 260 V ACPower supply90 ... 260 V AC

Terminal No.1234 5 6 7

AC version

Optocoupler collector output Optocoupler emitter outputSETINP BINP AGND+24 V out

Connection assignment X1

21 3 4 5 6 721

X2X1

Counter / Timer / Tachometer

Technical Specifications

• Extremely bright, large LED indicator• 1 pre-select value with transistor output• PNP and NPN sensors can be connected• Adding/subtracting via 2 separate inputs

• Counter/Timer/Tachometer• Extremely bright, large LED indicator• 1 pre-select value with transistor output• PNP and NPN sensors can be connec-

ted• Adding/subtracting via 2 separate in-

puts• Protection degree IP65 (front only)

Dimensions

Electrical connection

KCT2-6ST-VGeneral specificationsPre-selection singleProgramming keypad-driven menuIndicators/operating meansType 7-segment LED display, redNumber of decades 6Display value digit height 14 mmPre-selection active at counter value ≤ 0Display interval -199999 ... 999999 with suppression of leading zerosDecimal point 0 to max 3 fractional digitsScale factor 0.0001 ... 99.9999Reset manually or externalKey interlock -Electrical specificationsOperating voltage 90 ... 260 V ACPower consumption max. 6 VAInputCounting frequency 30 Hz / 20 kHz (max. 11 kHz when counting with phase discriminator)Impedance 10 kOhmVoltage low: 0 ... 4 V DC ; high: 12 ... 30 V DCCounting method adding or subtractingOutputSensor supply 24 V DC ± 15 % / 100 mAOptocoupler NPN, offener Kollektor und offener Emitter

30 V / 15 mAMechanical specificationsConnection 2-pin and 7-pin plug-in connection terminals, core cross-section ≤ 1.5 mm2

Mass approx. 150 g

Control panel cutout

96

48

44.9

x91.

9

92+0.8

67.1 6.5

4

max. 19

45+

0.6

12

Connection assignment X2

Terminal No. 1 2

AC version

Power supply90 ... 260 V ACPower supply90 ... 260 V AC

Terminal No.1234 5 6 7

AC version

Optocoupler collector output Optocoupler emitter outputSETINP BINP AGND+24 V out

Connection assignment X1

21 3 4 5 6 721

X2X1

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 13: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1091Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Special Functions Devices

• Counter/Timer/Tachometer• Extremely bright, large LED indicator• 1 pre-select value with transistor output• PNP and NPN sensors can be connec-

ted• Adding/subtracting via 2 separate in-

puts• Protection degree IP65 (front only)

Dimensions

Electrical connection

KCT2-6ST-VGeneral specificationsPre-selection singleProgramming keypad-driven menuIndicators/operating meansType 7-segment LED display, redNumber of decades 6Display value digit height 14 mmPre-selection active at counter value ≤ 0Display interval -199999 ... 999999 with suppression of leading zerosDecimal point 0 to max 3 fractional digitsScale factor 0.0001 ... 99.9999Reset manually or externalKey interlock -Electrical specificationsOperating voltage 90 ... 260 V ACPower consumption max. 6 VAInputCounting frequency 30 Hz / 20 kHz (max. 11 kHz when counting with phase discriminator)Impedance 10 kOhmVoltage low: 0 ... 4 V DC ; high: 12 ... 30 V DCCounting method adding or subtractingOutputSensor supply 24 V DC ± 15 % / 100 mAOptocoupler NPN, offener Kollektor und offener Emitter

30 V / 15 mAMechanical specificationsConnection 2-pin and 7-pin plug-in connection terminals, core cross-section ≤ 1.5 mm2

Mass approx. 150 g

Control panel cutout

96

48

44.9

x91.

9

92+0.8

67.1 6.5

4

max. 19

45+

0.6

12

Connection assignment X2

Terminal No. 1 2

AC version

Power supply90 ... 260 V ACPower supply90 ... 260 V AC

Terminal No.1234 5 6 7

AC version

Optocoupler collector output Optocoupler emitter outputSETINP BINP AGND+24 V out

Connection assignment X1

21 3 4 5 6 721

X2X1

Wiring Diagrams

Dimensions

• Counter/Timer/Tachometer• Extremely bright, large LED indicator• 1 pre-select value with transistor output• PNP and NPN sensors can be connec-

ted• Adding/subtracting via 2 separate in-

puts• Protection degree IP65 (front only)

Dimensions

Electrical connection

KCT2-6ST-VGeneral specificationsPre-selection singleProgramming keypad-driven menuIndicators/operating meansType 7-segment LED display, redNumber of decades 6Display value digit height 14 mmPre-selection active at counter value ≤ 0Display interval -199999 ... 999999 with suppression of leading zerosDecimal point 0 to max 3 fractional digitsScale factor 0.0001 ... 99.9999Reset manually or externalKey interlock -Electrical specificationsOperating voltage 90 ... 260 V ACPower consumption max. 6 VAInputCounting frequency 30 Hz / 20 kHz (max. 11 kHz when counting with phase discriminator)Impedance 10 kOhmVoltage low: 0 ... 4 V DC ; high: 12 ... 30 V DCCounting method adding or subtractingOutputSensor supply 24 V DC ± 15 % / 100 mAOptocoupler NPN, offener Kollektor und offener Emitter

30 V / 15 mAMechanical specificationsConnection 2-pin and 7-pin plug-in connection terminals, core cross-section ≤ 1.5 mm2

Mass approx. 150 g

Control panel cutout

96

48

44.9

x91.

9

92+0.8

67.1 6.5

4

max. 19

45+

0.6

12

Connection assignment X2

Terminal No. 1 2

AC version

Power supply90 ... 260 V ACPower supply90 ... 260 V AC

Terminal No.1234 5 6 7

AC version

Optocoupler collector output Optocoupler emitter outputSETINP BINP AGND+24 V out

Connection assignment X1

21 3 4 5 6 721

X2X1Terminal Connection

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 14: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1092 Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Spec

ial F

unct

ions

Dev

ices

• 1-channel terminal amplifier• NAMUR sensor input• DC 24 V supply voltage• Standard interface for prevention of sig-

nal transmission errors• Switching status indicator, yellow LED• Short-circuit proof electronic output• Low noise sensitivity• Compact terminal housing• Mounting by clipping onto standard

35 mm rail to DIN EN 50022• Protection degree IP20

Dimensions

Electrical connection

KCD2-E KCD2-E1 KCD2-E2 KCD2-E3Indicators/operating meansLED yellow switch outputElectrical specificationsOperating voltage 10 ... 30 V DCOperating current approx. 22 mARipple ≤ 10 %Transfer characteristicsMode of operation NO NC NO NCSwitching frequency 1 kHz 1 kHz 1 kHz 1 kHzInputConnection terminals 1+, 2- terminals 1+, 2- terminals 1+, 2- terminals 1+, 2-Connectable sensor types NAMUR NAMUR NAMUR NAMURShort-circuit current approx. 8 mA approx. 8 mA approx. 8 mA approx. 8 mASensor supply 8 V DC 8 V DC 8 V DC,

max. 9 V DC at input resistance

min. 562 Ω

8 V DC

Switching point 1.2 ... 2.1 mA hys-teresis approx. 0.2

mA

1.2 ... 2.1 mA hys-teresis approx. 0.2

mA

1.2 ... 2.1 mA hys-teresis approx. 0.2

mA

1.2 ... 2.1 mA hys-teresis approx. 0.2

mALead monitoring without without without withoutTrip value 1 kHz 1 kHz 1 kHz 1 kHzOutputConnection terminal 4- terminal 4- terminal 4+ terminal 4+Current 200 mA short-cir-

cuit proof200 mA short-cir-

cuit proof200 mA short-cir-

cuit proof200 mA short-cir-

cuit proofTransistor NPN NPN PNP PNPMechanical specificationsConnection self-opening apparatus connection terminals, max. core cross-section 0.34 ... 2.5

mm2

Mass 60 g

4020

60

54 6

21 3

LED

5+6-4+

1+ 2-

1+ 2- 3

Supplyvoltage

Output

Input

Sensor

I ≤0.1 mA

• 1-channel terminal amplifier• NAMUR sensor input• DC 24 V supply voltage• Standard interface for prevention of sig-

nal transmission errors• Switching status indicator, yellow LED• Short-circuit proof electronic output• Low noise sensitivity• Compact terminal housing• Mounting by clipping onto standard

35 mm rail to DIN EN 50022• Protection degree IP20

Dimensions

Electrical connection

KCD2-E KCD2-E1 KCD2-E2 KCD2-E3Indicators/operating meansLED yellow switch outputElectrical specificationsOperating voltage 10 ... 30 V DCOperating current approx. 22 mARipple ≤ 10 %Transfer characteristicsMode of operation NO NC NO NCSwitching frequency 1 kHz 1 kHz 1 kHz 1 kHzInputConnection terminals 1+, 2- terminals 1+, 2- terminals 1+, 2- terminals 1+, 2-Connectable sensor types NAMUR NAMUR NAMUR NAMURShort-circuit current approx. 8 mA approx. 8 mA approx. 8 mA approx. 8 mASensor supply 8 V DC 8 V DC 8 V DC,

max. 9 V DC at input resistance

min. 562 Ω

8 V DC

Switching point 1.2 ... 2.1 mA hys-teresis approx. 0.2

mA

1.2 ... 2.1 mA hys-teresis approx. 0.2

mA

1.2 ... 2.1 mA hys-teresis approx. 0.2

mA

1.2 ... 2.1 mA hys-teresis approx. 0.2

mALead monitoring without without without withoutTrip value 1 kHz 1 kHz 1 kHz 1 kHzOutputConnection terminal 4- terminal 4- terminal 4+ terminal 4+Current 200 mA short-cir-

cuit proof200 mA short-cir-

cuit proof200 mA short-cir-

cuit proof200 mA short-cir-

cuit proofTransistor NPN NPN PNP PNPMechanical specificationsConnection self-opening apparatus connection terminals, max. core cross-section 0.34 ... 2.5

mm2

Mass 60 g

4020

60

54 6

21 3

LED

5+6-4+

1+ 2-

1+ 2- 3

Supplyvoltage

Output

Input

Sensor

I ≤0.1 mA

Terminal Amplifier/Converter

Technical Specifications

• 1 -channel terminal amplifier• NAMUR sensor input – NPN or PNP output• DC 24 V supply voltage• Switching status indicator, yellow LED• Short-circuit proof electronic output• Compact terminal housing• Mounting by clipping onto standard

35 mm rail

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 15: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1093Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Special Functions Devices

Wiring Diagrams

Dimensions

• 1-channel terminal amplifier• NAMUR sensor input• DC 24 V supply voltage• Standard interface for prevention of sig-

nal transmission errors• Switching status indicator, yellow LED• Short-circuit proof electronic output• Low noise sensitivity• Compact terminal housing• Mounting by clipping onto standard

35 mm rail to DIN EN 50022• Protection degree IP20

Dimensions

Electrical connection

KCD2-E KCD2-E1 KCD2-E2 KCD2-E3Indicators/operating meansLED yellow switch outputElectrical specificationsOperating voltage 10 ... 30 V DCOperating current approx. 22 mARipple ≤ 10 %Transfer characteristicsMode of operation NO NC NO NCSwitching frequency 1 kHz 1 kHz 1 kHz 1 kHzInputConnection terminals 1+, 2- terminals 1+, 2- terminals 1+, 2- terminals 1+, 2-Connectable sensor types NAMUR NAMUR NAMUR NAMURShort-circuit current approx. 8 mA approx. 8 mA approx. 8 mA approx. 8 mASensor supply 8 V DC 8 V DC 8 V DC,

max. 9 V DC at input resistance

min. 562 Ω

8 V DC

Switching point 1.2 ... 2.1 mA hys-teresis approx. 0.2

mA

1.2 ... 2.1 mA hys-teresis approx. 0.2

mA

1.2 ... 2.1 mA hys-teresis approx. 0.2

mA

1.2 ... 2.1 mA hys-teresis approx. 0.2

mALead monitoring without without without withoutTrip value 1 kHz 1 kHz 1 kHz 1 kHzOutputConnection terminal 4- terminal 4- terminal 4+ terminal 4+Current 200 mA short-cir-

cuit proof200 mA short-cir-

cuit proof200 mA short-cir-

cuit proof200 mA short-cir-

cuit proofTransistor NPN NPN PNP PNPMechanical specificationsConnection self-opening apparatus connection terminals, max. core cross-section 0.34 ... 2.5

mm2

Mass 60 g

4020

60

54 6

21 3

LED

5+6-4+

1+ 2-

1+ 2- 3

Supplyvoltage

Output

Input

Sensor

I ≤0.1 mA

Terminal Connection

•1-

chan

nel

ter

min

al a

mp

lifie

r•

NA

MU

R s

enso

r in

pu

t•

DC

24

V s

up

ply

vo

ltag

e•

Sta

nd

ard

inte

rfac

e fo

r p

reve

nti

on

of s

ig-

nal

tra

nsm

issi

on

err

ors

•S

wit

chin

g s

tatu

s in

dic

ato

r, y

ello

w L

ED

•S

ho

rt-c

ircu

it p

roo

f el

ectr

on

ic o

utp

ut

•L

ow

no

ise

sen

siti

vity

•C

om

pac

t te

rmin

al h

ou

sin

g•

Mo

un

tin

g b

y cl

ipp

ing

on

to s

tan

dar

d

35m

m r

ail t

o D

INE

N50

022

•P

rote

ctio

n d

egre

e IP

20

Dim

ensi

on

s

Ele

ctri

cal c

on

nec

tio

n

KC

D2-

EK

CD

2-E

1K

CD

2-E

2K

CD

2-E

3In

dica

tors

/ope

ratin

g m

ean

sLE

D y

ello

w

switc

h o

utpu

tE

lect

rica

l sp

ecifi

cati

ons

Ope

ratin

g vo

ltage

10

...

30 V

DC

Ope

ratin

g cu

rren

t ap

prox

. 22

mA

Rip

ple

≤ 10

%Tr

ansf

er c

har

acte

rist

ics

Mod

e of

ope

ratio

n N

ON

CN

ON

CS

witc

hing

freq

uenc

y 1

kHz

1 kH

z1

kHz

1 kH

zIn

put

Con

nect

ion

term

inal

s 1+

, 2-

term

inal

s 1+

, 2-

term

inal

s 1+

, 2-

term

inal

s 1+

, 2-

Con

nect

able

sen

sor

type

s N

AM

UR

NA

MU

RN

AM

UR

NA

MU

RS

hort

-circ

uit c

urre

nt

appr

ox. 8

mA

appr

ox. 8

mA

appr

ox. 8

mA

appr

ox. 8

mA

Sen

sor

supp

ly

8 V

DC

8 V

DC

8 V

DC

, m

ax. 9

VD

C a

t in

put r

esis

tanc

e m

in. 5

62Ω

8 V

DC

Sw

itchi

ng p

oint

1.

2 ...

2.1

mA

hys

-te

resi

s ap

prox

. 0.2

m

A

1.2

... 2

.1 m

A h

ys-

tere

sis

appr

ox. 0

.2

mA

1.2

... 2

.1 m

A h

ys-

tere

sis

appr

ox. 0

.2

mA

1.2

... 2

.1 m

A h

ys-

tere

sis

appr

ox. 0

.2

mA

Lead

mon

itorin

g w

ithou

tw

ithou

tw

itho

utw

itho

utT

rip v

alue

1

kHz

1 kH

z1

kHz

1 kH

zO

utp

utC

onne

ctio

n te

rmin

al 4

-te

rmin

al 4

-te

rmin

al 4

+te

rmin

al 4

+C

urre

nt

200

mA

sho

rt-c

ir-cu

it pr

oof

200

mA

sho

rt-c

ir-cu

it pr

oof

200

mA

sho

rt-c

ir-cu

it pr

oof

200

mA

sho

rt-c

ir-cu

it pr

oof

Tra

nsis

tor

NP

NN

PN

PN

PP

NP

Mec

han

ical

spe

cific

atio

nsC

onne

ctio

n se

lf-op

enin

g ap

para

tus

conn

ectio

n te

rmin

als,

max

. cor

e cr

oss-

sect

ion

0.34

...

2.5

mm

2

Mas

s 60

g

4020

60

54

6

21

3

LED

5+6-

4+

1+2-

1+2-

3

Sup

ply

volta

geO

utpu

t

Inpu

t

Sen

sor

I ≤0.

1 m

A

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 16: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1094 Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Spec

ial F

unct

ions

Dev

ices

Terminal Amplifier/Converter

• 1-channel terminal amplifier• NAMUR sensor input• DC 24 V supply voltage• Standard interface for prevention of sig-

nal transmission errors• Switching status indicator, yellow LED• Lead breakage monitoring: The lead

breakage monitoring can be disconnec-ted by bridging terminals 1 and 3 (When using a mechanical contact a 10 kOhm resistor is required in parallel circuit)

• Short-circuit proof electronic output• Low noise sensitivity• Compact terminal housing• Mounting by clipping onto standard

35 mm rail to DIN EN 50022• Protection degree IP20

Dimensions

Electrical connection

KCD2-EL KCD2-E2LIndicators/operating meansLED yellow switch outputElectrical specificationsOperating voltage 10 ... 30 V DCOperating current approx. 22 mARipple ≤ 10 %Transfer characteristicsMode of operation NOSwitching frequency 1 kHzInputConnection terminals 1+, 2-Connectable sensor types NAMURShort-circuit current approx. 8 mASensor supply 8 V DCSwitching point 1.2 ... 2.1 mA hysteresis approx. 0.2 mALead monitoring withTrip value 1 kHzOutputConnection terminal 4- terminal 4+Current 200 mA short-circuit proof 200 mA short-circuit proofTransistor NPN PNPMechanical specificationsConnection self-opening apparatus connection terminals, max. core cross-section 0.34 ... 2.5

mm2

Mass 60 g

4020

60

54 6

21 3

LED

Supplyvoltage

Output

Input

Lead breakagemonitoring

Sensor

I ≤0.1 mA

5+6-4-

1+

1+

2-

1+ 2- 3

3

Technical Specifications

• 1-channel terminal amplifier• NAMUR sensor input – NPN or PNP output• DC 24 V supply voltage• Switching status indicator, yellow LED• Lead breakage monitoring• Short-circuit proof electronic output• Low noise sensitivity• Compact terminal housing• Mounting by clipping onto standard

35 mm rail to DINEN50022

• 1-channel terminal amplifier• NAMUR sensor input• DC 24 V supply voltage• Standard interface for prevention of sig-

nal transmission errors• Switching status indicator, yellow LED• Lead breakage monitoring: The lead

breakage monitoring can be disconnec-ted by bridging terminals 1 and 3 (When using a mechanical contact a 10 kOhm resistor is required in parallel circuit)

• Short-circuit proof electronic output• Low noise sensitivity• Compact terminal housing• Mounting by clipping onto standard

35 mm rail to DIN EN 50022• Protection degree IP20

Dimensions

Electrical connection

KCD2-EL KCD2-E2LIndicators/operating meansLED yellow switch outputElectrical specificationsOperating voltage 10 ... 30 V DCOperating current approx. 22 mARipple ≤ 10 %Transfer characteristicsMode of operation NOSwitching frequency 1 kHzInputConnection terminals 1+, 2-Connectable sensor types NAMURShort-circuit current approx. 8 mASensor supply 8 V DCSwitching point 1.2 ... 2.1 mA hysteresis approx. 0.2 mALead monitoring withTrip value 1 kHzOutputConnection terminal 4- terminal 4+Current 200 mA short-circuit proof 200 mA short-circuit proofTransistor NPN PNPMechanical specificationsConnection self-opening apparatus connection terminals, max. core cross-section 0.34 ... 2.5

mm2

Mass 60 g

4020

60

54 6

21 3

LED

Supplyvoltage

Output

Input

Lead breakagemonitoring

Sensor

I ≤0.1 mA

5+6-4-

1+

1+

2-

1+ 2- 3

3

Note: Lead breakage monitoring can be disabled via jumper connection between terminals 1 and 3.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 17: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1095Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Special Functions Devices

•1-

chan

nel

ter

min

al a

mp

lifie

r•

NA

MU

R s

enso

r in

pu

t•

DC

24

V s

up

ply

vo

ltag

e•

Sta

nd

ard

inte

rfac

e fo

r p

reve

nti

on

of s

ig-

nal

tra

nsm

issi

on

err

ors

•S

wit

chin

g s

tatu

s in

dic

ato

r, y

ello

w L

ED

•L

ead

bre

akag

e m

on

ito

rin

g:

Th

e le

ad

bre

akag

e m

on

ito

rin

g c

an b

e d

isco

nn

ec-

ted

by

bri

dg

ing

term

inal

s 1

and

3 (W

hen

u

sin

g a

mec

han

ical

co

nta

ct a

10

kOh

m

resi

sto

r is

req

uir

ed in

par

alle

l cir

cuit

)•

Sh

ort

-cir

cuit

pro

of

elec

tro

nic

ou

tpu

t•

Lo

w n

ois

e se

nsi

tivi

ty•

Co

mp

act

term

inal

ho

usi

ng

•M

ou

nti

ng

by

clip

pin

g o

nto

sta

nd

ard

35

mm

rai

l to

DIN

EN

5002

2•

Pro

tect

ion

deg

ree

IP20

Dim

ensi

on

s

Ele

ctri

cal c

on

nec

tio

n

KC

D2-

EL

KC

D2-

E2L

Ind

icat

ors

/op

erat

ing

mea

ns

LED

yel

low

sw

itch

outp

utE

lect

rica

l spe

cific

atio

ns

Ope

ratin

g vo

ltage

10

... 3

0 V

DC

Ope

ratin

g cu

rren

t ap

prox

. 22

mA

Rip

ple

≤ 10

%T

ran

sfer

cha

ract

eris

tics

Mod

e of

ope

ratio

n N

OS

witc

hing

freq

uenc

y 1

kHz

Inp

utC

onne

ctio

n te

rmin

als

1+,

2-C

onne

ctab

le s

enso

r ty

pes

NA

MU

RS

hort

-circ

uit c

urre

nt

appr

ox. 8

mA

Sen

sor

supp

ly

8 V

DC

Sw

itchi

ng p

oint

1.

2 ...

2.1

mA

hys

tere

sis

appr

ox. 0

.2 m

ALe

ad m

onito

ring

with

Trip

val

ue

1 kH

zO

utp

ut

Con

nect

ion

term

inal

4-

term

inal

4+

Cur

rent

20

0 m

A s

hort

-circ

uit p

roof

200

mA

sho

rt-c

ircui

t pro

ofT

rans

isto

r N

PN

PN

PM

echa

nic

al s

pec

ifica

tions

Con

nect

ion

self-

open

ing

appa

ratu

s co

nnec

tion

term

inal

s, m

ax. c

ore

cros

s-se

ctio

n 0.

34 ..

. 2.5

m

m2

Mas

s 60

g

4020

60

54

6

21

3

LED

Sup

ply

volta

geO

utpu

t

Inpu

t

Lead

bre

akag

em

onito

ring

Sen

sor

I ≤0.

1 m

A

5+6-

4-

1+ 1+

2-

1+2-

33

Wiring Diagrams

Dimensions

• 1-channel terminal amplifier• NAMUR sensor input• DC 24 V supply voltage• Standard interface for prevention of sig-

nal transmission errors• Switching status indicator, yellow LED• Lead breakage monitoring: The lead

breakage monitoring can be disconnec-ted by bridging terminals 1 and 3 (When using a mechanical contact a 10 kOhm resistor is required in parallel circuit)

• Short-circuit proof electronic output• Low noise sensitivity• Compact terminal housing• Mounting by clipping onto standard

35 mm rail to DIN EN 50022• Protection degree IP20

Dimensions

Electrical connection

KCD2-EL KCD2-E2LIndicators/operating meansLED yellow switch outputElectrical specificationsOperating voltage 10 ... 30 V DCOperating current approx. 22 mARipple ≤ 10 %Transfer characteristicsMode of operation NOSwitching frequency 1 kHzInputConnection terminals 1+, 2-Connectable sensor types NAMURShort-circuit current approx. 8 mASensor supply 8 V DCSwitching point 1.2 ... 2.1 mA hysteresis approx. 0.2 mALead monitoring withTrip value 1 kHzOutputConnection terminal 4- terminal 4+Current 200 mA short-circuit proof 200 mA short-circuit proofTransistor NPN PNPMechanical specificationsConnection self-opening apparatus connection terminals, max. core cross-section 0.34 ... 2.5

mm2

Mass 60 g

4020

6054 6

21 3

LED

Supplyvoltage

Output

Input

Lead breakagemonitoring

Sensor

I ≤0.1 mA

5+6-4-

1+

1+

2-

1+ 2- 3

3

Terminal Connection

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 18: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1096 Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Spec

ial F

unct

ions

Dev

ices

• Relay output with 1 pole, indication of the switching state LED yellow

• Free-wheeling diode• Compact terminal housing• Mounting by clipping onto standard

35 mm rail to DIN EN 50022• Protection degree IP20

Dimensions

Electrical connection

KCD2-RIndicators/operating meansLED yellow switch outputElectrical specificationsOperating voltage 24 V DC ± 15 %Operating current 16 mARipple ≤ 10 %InputConnection terminals 2+, 3-Connectable sensor types PNP or NPN 3-wire sensorsOutputSwitching frequency ≤ 10 HzRelay 1 changeover contactContact loading 250 V AC/2A/cos φ≥0.7

30 V DC/2 A resistive loadMechanical life ≥108 switching cyclesMechanical specificationsConnection self-opening apparatus connection terminals,

max. core cross-section 0.34 ... 2.5 mm2

Mass 60 g

4020

60

54 6

21 3

LED

564

2+3-

Output

Input

Sensor Output Converter

Technical Specifications

• Relay output with 1 pole, indication of the switching state LED yellow

• Free-wheeling diode• Compact terminal housing• Mounting by clipping onto

standard 35mm• PNPN or PNP input

• Relay output with 1 pole, indication of the switching state LED yellow

• Free-wheeling diode• Compact terminal housing• Mounting by clipping onto standard

35 mm rail to DIN EN 50022• Protection degree IP20

Dimensions

Electrical connection

KCD2-RIndicators/operating meansLED yellow switch outputElectrical specificationsOperating voltage 24 V DC ± 15 %Operating current 16 mARipple ≤ 10 %InputConnection terminals 2+, 3-Connectable sensor types PNP or NPN 3-wire sensorsOutputSwitching frequency ≤ 10 HzRelay 1 changeover contactContact loading 250 V AC/2A/cos φ≥0.7

30 V DC/2 A resistive loadMechanical life ≥108 switching cyclesMechanical specificationsConnection self-opening apparatus connection terminals,

max. core cross-section 0.34 ... 2.5 mm2

Mass 60 g

4020

60

54 6

21 3

LED

564

2+3-

Output

Input

Note: This device can be used to convert NPN/PNP sensor outputs to relay contact output. The sensor must be supplied from a separate power supply unit.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 19: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1097Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Special Functions Devices

• Relay output with 1 pole, indication of the switching state LED yellow

• Free-wheeling diode• Compact terminal housing• Mounting by clipping onto standard

35 mm rail to DIN EN 50022• Protection degree IP20

Dimensions

Electrical connection

KCD2-RIndicators/operating meansLED yellow switch outputElectrical specificationsOperating voltage 24 V DC ± 15 %Operating current 16 mARipple ≤ 10 %InputConnection terminals 2+, 3-Connectable sensor types PNP or NPN 3-wire sensorsOutputSwitching frequency ≤ 10 HzRelay 1 changeover contactContact loading 250 V AC/2A/cos φ≥0.7

30 V DC/2 A resistive loadMechanical life ≥108 switching cyclesMechanical specificationsConnection self-opening apparatus connection terminals,

max. core cross-section 0.34 ... 2.5 mm2

Mass 60 g

4020

6054 6

21 3

LED

564

2+3-

Output

Input

Wiring Diagrams

Dimensions

• Relay output with 1 pole, indication of the switching state LED yellow

• Free-wheeling diode• Compact terminal housing• Mounting by clipping onto standard

35 mm rail to DIN EN 50022• Protection degree IP20

Dimensions

Electrical connection

KCD2-RIndicators/operating meansLED yellow switch outputElectrical specificationsOperating voltage 24 V DC ± 15 %Operating current 16 mARipple ≤ 10 %InputConnection terminals 2+, 3-Connectable sensor types PNP or NPN 3-wire sensorsOutputSwitching frequency ≤ 10 HzRelay 1 changeover contactContact loading 250 V AC/2A/cos φ≥0.7

30 V DC/2 A resistive loadMechanical life ≥108 switching cyclesMechanical specificationsConnection self-opening apparatus connection terminals,

max. core cross-section 0.34 ... 2.5 mm2

Mass 60 g

4020

6054 6

21 3

LED

564

2+3-

Output

Input

Terminal Connection

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 20: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1098 Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Spec

ial F

unct

ions

Dev

ices

Speed Monitoring

• Speed monitoring up to;40;kHz• 1 pre-select value with relay output and

LED indicator• 2-, 3-, 4-wire and NAMUR sensors as

well as rotary encoder connectable• Start-up delay• Menu driven operation via 4 front keys• Period measurement• Output signal can be inverted• Display devices can be set between

0.1 ... 2.5 sec.

Dimensions

Electrical connection

KFU8-DW-1.DSupplyRated voltage 196 ... 264 V AC ; 98 ... 132 V AC; 47 ... 63 Hz

20.4 ... 28 V DCPower consumption AC: < 5 VA

DC: < 5 WIndicators/operating meansType 4-digit 7-segment display, red, 7 mm digit heightDisplay interval 0.002 ... 9999 Hz or

0,01 ... 9999 min-1

Parameter assignment keypad-driven menuSwitching state LED yellow, 3 mmInput 1Connectable sensor types NAMUR sensors according to DIN EN 60947-5-6Open loop voltage 8.2 V DCShort-circuit current 6.5 mASwitching point 1.2 ... 2.1 mA Switching hysteresis approx. 0.2 mAInput 2Connectable sensor types Two, three, or four-wire proximity switch, incremental rotary encoder, or externally

generated pulses 16 ... 30 VSensor supply 19 ... 28 V DC non-stabilised; ≤ 30 mA short-circuit proofSwitching point high: 16 ... 30 V DC; max.10 mA due to integrated constant current sink; Ri ≅ 3 kΩ

low: 0 ... 6 V DCInput frequency 0.002 ... 40000 Hz, pulse length/duration: ≥ 12µsInput 3Start-up override Triggering by external signal 16 ... 30 V or Place jumper between terminals 2/3 or

by switching on supply voltage (terminal 2 and terminal 3 permanently bridged)Jumpering time 0.1 ... 999.9 s (External trigger signal)OutputRelay 1 changeover contact

NO, NC, COMSensor supply 24 V DC ± 10 %, 30 mA , short-circuit proofContact loading 250 V AC/2 A/ cos φ ≥ 0.7

40 V DC/2 ATransfer characteristicsMeasuring error 0 ... 40000 Hz: ≤ ±0,10%

Display: ±1 digitTimer function Rise/fall delay, wipe contact, pulse extensionTime 0 ... 999.9 s ; Direction of action reversibleAmbient conditionsAmbient temperature -25 ... 60 °C (248 ... 333 K)Mechanical specificationsProtection degree IP20Connection coded, removable terminals , max. core cross-section 0.34 ... 2.5 mm2

Mode

Output Drehzahlwächter Speed monitor

Enter

+

1 2 3 4 5 6

13 14 15 16 17 187 8 9 10 11 12

PEPPERL+FUCHS GERMANY

Control keys

7-segment-display

Yellow LED, Relay switch state indication

107

93

115

L+

L–89

L+

L–

151413

7

L+

L–89

L+

L– 13

71514

L+

L–

151413

7 L+

L– 13

71514

L+

L–

151413

7 L+

L–

L+16-30 V

0 V L–

1514

1514

13

7

yellow

NAMUR Sensor

NAMUR Encoder

DC-3-wire sensor, PNP

DC-3-wire sensor, NPN

DC-2-wire sensor, PNP

DC-2-wire sensor, NPN

Encoder, push-pull

Encoder, push-pull

Power supply 24 V DC

Power supply 230 V AC

Power supply 115 V AC

Not connected

Sensor power supply GND

Sensor power supply GND

Sensor power supply 24 V DC

Sensor power supply 24 V DC

Trigger input for start-up bypass

External trigger signal

Bridge fitted: start-up bypass triggered by switching on the power supply

Relay output

External rectangular signal

Galvanically isolated input

9NAMUR L+

NAMUR L-8

73

2

1

15

14

13

6

COM

NC

NO

4L+

5L-

16L1 (230 V)

17L1 (115 V)

18N

12

11

10

Technical Specifications

• Speed monitoring up to 40 kHz• 1 pre-select value with relay output and

LED indicator• 2-, 3-, 4-wire and NAMUR sensors as

well as rotary encoder connectable• Start-up delay• Menu driven operation via 4 front keys• Period measurement• Output signal can be inverted• Display devices can be set between

0.1...2.5 sec.

• Speed monitoring up to;40;kHz• 1 pre-select value with relay output and

LED indicator• 2-, 3-, 4-wire and NAMUR sensors as

well as rotary encoder connectable• Start-up delay• Menu driven operation via 4 front keys• Period measurement• Output signal can be inverted• Display devices can be set between

0.1 ... 2.5 sec.

Dimensions

Electrical connection

KFU8-DW-1.DSupplyRated voltage 196 ... 264 V AC ; 98 ... 132 V AC; 47 ... 63 Hz

20.4 ... 28 V DCPower consumption AC: < 5 VA

DC: < 5 WIndicators/operating meansType 4-digit 7-segment display, red, 7 mm digit heightDisplay interval 0.002 ... 9999 Hz or

0,01 ... 9999 min-1

Parameter assignment keypad-driven menuSwitching state LED yellow, 3 mmInput 1Connectable sensor types NAMUR sensors according to DIN EN 60947-5-6Open loop voltage 8.2 V DCShort-circuit current 6.5 mASwitching point 1.2 ... 2.1 mA Switching hysteresis approx. 0.2 mAInput 2Connectable sensor types Two, three, or four-wire proximity switch, incremental rotary encoder, or externally

generated pulses 16 ... 30 VSensor supply 19 ... 28 V DC non-stabilised; ≤ 30 mA short-circuit proofSwitching point high: 16 ... 30 V DC; max.10 mA due to integrated constant current sink; Ri ≅ 3 kΩ

low: 0 ... 6 V DCInput frequency 0.002 ... 40000 Hz, pulse length/duration: ≥ 12µsInput 3Start-up override Triggering by external signal 16 ... 30 V or Place jumper between terminals 2/3 or

by switching on supply voltage (terminal 2 and terminal 3 permanently bridged)Jumpering time 0.1 ... 999.9 s (External trigger signal)OutputRelay 1 changeover contact

NO, NC, COMSensor supply 24 V DC ± 10 %, 30 mA , short-circuit proofContact loading 250 V AC/2 A/ cos φ ≥ 0.7

40 V DC/2 ATransfer characteristicsMeasuring error 0 ... 40000 Hz: ≤ ±0,10%

Display: ±1 digitTimer function Rise/fall delay, wipe contact, pulse extensionTime 0 ... 999.9 s ; Direction of action reversibleAmbient conditionsAmbient temperature -25 ... 60 °C (248 ... 333 K)Mechanical specificationsProtection degree IP20Connection coded, removable terminals , max. core cross-section 0.34 ... 2.5 mm2

Mode

Output Drehzahlwächter Speed monitor

Enter

+

1 2 3 4 5 6

13 14 15 16 17 187 8 9 10 11 12

PEPPERL+FUCHS GERMANY

Control keys

7-segment-display

Yellow LED, Relay switch state indication

107

93

115

L+

L–89

L+

L–

151413

7

L+

L–89

L+

L– 13

71514

L+

L–

151413

7 L+

L– 13

71514

L+

L–

151413

7 L+

L–

L+16-30 V

0 V L–

1514

1514

13

7

yellow

NAMUR Sensor

NAMUR Encoder

DC-3-wire sensor, PNP

DC-3-wire sensor, NPN

DC-2-wire sensor, PNP

DC-2-wire sensor, NPN

Encoder, push-pull

Encoder, push-pull

Power supply 24 V DC

Power supply 230 V AC

Power supply 115 V AC

Not connected

Sensor power supply GND

Sensor power supply GND

Sensor power supply 24 V DC

Sensor power supply 24 V DC

Trigger input for start-up bypass

External trigger signal

Bridge fitted: start-up bypass triggered by switching on the power supply

Relay output

External rectangular signal

Galvanically isolated input

9NAMUR L+

NAMUR L-8

73

2

1

15

14

13

6

COM

NC

NO

4L+

5L-

16L1 (230 V)

17L1 (115 V)

18N

12

11

10

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 21: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1099Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Special Functions Devices

Dimensions

• Speed monitoring up to;40;kHz• 1 pre-select value with relay output and

LED indicator• 2-, 3-, 4-wire and NAMUR sensors as

well as rotary encoder connectable• Start-up delay• Menu driven operation via 4 front keys• Period measurement• Output signal can be inverted• Display devices can be set between

0.1 ... 2.5 sec.

Dimensions

Electrical connection

KFU8-DW-1.DSupplyRated voltage 196 ... 264 V AC ; 98 ... 132 V AC; 47 ... 63 Hz

20.4 ... 28 V DCPower consumption AC: < 5 VA

DC: < 5 WIndicators/operating meansType 4-digit 7-segment display, red, 7 mm digit heightDisplay interval 0.002 ... 9999 Hz or

0,01 ... 9999 min-1

Parameter assignment keypad-driven menuSwitching state LED yellow, 3 mmInput 1Connectable sensor types NAMUR sensors according to DIN EN 60947-5-6Open loop voltage 8.2 V DCShort-circuit current 6.5 mASwitching point 1.2 ... 2.1 mA Switching hysteresis approx. 0.2 mAInput 2Connectable sensor types Two, three, or four-wire proximity switch, incremental rotary encoder, or externally

generated pulses 16 ... 30 VSensor supply 19 ... 28 V DC non-stabilised; ≤ 30 mA short-circuit proofSwitching point high: 16 ... 30 V DC; max.10 mA due to integrated constant current sink; Ri ≅ 3 kΩ

low: 0 ... 6 V DCInput frequency 0.002 ... 40000 Hz, pulse length/duration: ≥ 12µsInput 3Start-up override Triggering by external signal 16 ... 30 V or Place jumper between terminals 2/3 or

by switching on supply voltage (terminal 2 and terminal 3 permanently bridged)Jumpering time 0.1 ... 999.9 s (External trigger signal)OutputRelay 1 changeover contact

NO, NC, COMSensor supply 24 V DC ± 10 %, 30 mA , short-circuit proofContact loading 250 V AC/2 A/ cos φ ≥ 0.7

40 V DC/2 ATransfer characteristicsMeasuring error 0 ... 40000 Hz: ≤ ±0,10%

Display: ±1 digitTimer function Rise/fall delay, wipe contact, pulse extensionTime 0 ... 999.9 s ; Direction of action reversibleAmbient conditionsAmbient temperature -25 ... 60 °C (248 ... 333 K)Mechanical specificationsProtection degree IP20Connection coded, removable terminals , max. core cross-section 0.34 ... 2.5 mm2

Mode

Output Drehzahlwächter Speed monitor

Enter

+

1 2 3 4 5 6

13 14 15 16 17 187 8 9 10 11 12

PEPPERL+FUCHS GERMANY

Control keys

7-segment-display

Yellow LED, Relay switch state indication

107

93

115

L+

L–89

L+

L–

151413

7

L+

L–89

L+

L– 13

71514

L+

L–

151413

7 L+

L– 13

71514

L+

L–

151413

7 L+

L–

L+16-30 V

0 V L–

1514

1514

13

7

yellow

NAMUR Sensor

NAMUR Encoder

DC-3-wire sensor, PNP

DC-3-wire sensor, NPN

DC-2-wire sensor, PNP

DC-2-wire sensor, NPN

Encoder, push-pull

Encoder, push-pull

Power supply 24 V DC

Power supply 230 V AC

Power supply 115 V AC

Not connected

Sensor power supply GND

Sensor power supply GND

Sensor power supply 24 V DC

Sensor power supply 24 V DC

Trigger input for start-up bypass

External trigger signal

Bridge fitted: start-up bypass triggered by switching on the power supply

Relay output

External rectangular signal

Galvanically isolated input

9NAMUR L+

NAMUR L-8

73

2

1

15

14

13

6

COM

NC

NO

4L+

5L-

16L1 (230 V)

17L1 (115 V)

18N

12

11

10

Wiring Diagrams

Terminal Connection

• Speed monitoring up to;40;kHz• 1 pre-select value with relay output and

LED indicator• 2-, 3-, 4-wire and NAMUR sensors as

well as rotary encoder connectable• Start-up delay• Menu driven operation via 4 front keys• Period measurement• Output signal can be inverted• Display devices can be set between

0.1 ... 2.5 sec.

Dimensions

Electrical connection

KFU8-DW-1.DSupplyRated voltage 196 ... 264 V AC ; 98 ... 132 V AC; 47 ... 63 Hz

20.4 ... 28 V DCPower consumption AC: < 5 VA

DC: < 5 WIndicators/operating meansType 4-digit 7-segment display, red, 7 mm digit heightDisplay interval 0.002 ... 9999 Hz or

0,01 ... 9999 min-1

Parameter assignment keypad-driven menuSwitching state LED yellow, 3 mmInput 1Connectable sensor types NAMUR sensors according to DIN EN 60947-5-6Open loop voltage 8.2 V DCShort-circuit current 6.5 mASwitching point 1.2 ... 2.1 mA Switching hysteresis approx. 0.2 mAInput 2Connectable sensor types Two, three, or four-wire proximity switch, incremental rotary encoder, or externally

generated pulses 16 ... 30 VSensor supply 19 ... 28 V DC non-stabilised; ≤ 30 mA short-circuit proofSwitching point high: 16 ... 30 V DC; max.10 mA due to integrated constant current sink; Ri ≅ 3 kΩ

low: 0 ... 6 V DCInput frequency 0.002 ... 40000 Hz, pulse length/duration: ≥ 12µsInput 3Start-up override Triggering by external signal 16 ... 30 V or Place jumper between terminals 2/3 or

by switching on supply voltage (terminal 2 and terminal 3 permanently bridged)Jumpering time 0.1 ... 999.9 s (External trigger signal)OutputRelay 1 changeover contact

NO, NC, COMSensor supply 24 V DC ± 10 %, 30 mA , short-circuit proofContact loading 250 V AC/2 A/ cos φ ≥ 0.7

40 V DC/2 ATransfer characteristicsMeasuring error 0 ... 40000 Hz: ≤ ±0,10%

Display: ±1 digitTimer function Rise/fall delay, wipe contact, pulse extensionTime 0 ... 999.9 s ; Direction of action reversibleAmbient conditionsAmbient temperature -25 ... 60 °C (248 ... 333 K)Mechanical specificationsProtection degree IP20Connection coded, removable terminals , max. core cross-section 0.34 ... 2.5 mm2

Mode

Output Drehzahlwächter Speed monitor

Enter

+

1 2 3 4 5 6

13 14 15 16 17 187 8 9 10 11 12

PEPPERL+FUCHS GERMANY

Control keys

7-segment-display

Yellow LED, Relay switch state indication

107

93

115

L+

L–89

L+

L–

151413

7

L+

L–89

L+

L– 13

71514

L+

L–

151413

7 L+

L– 13

71514

L+

L–

151413

7 L+

L–

L+16-30 V

0 V L–

1514

1514

13

7

yellow

NAMUR Sensor

NAMUR Encoder

DC-3-wire sensor, PNP

DC-3-wire sensor, NPN

DC-2-wire sensor, PNP

DC-2-wire sensor, NPN

Encoder, push-pull

Encoder, push-pull

Power supply 24 V DC

Power supply 230 V AC

Power supply 115 V AC

Not connected

Sensor power supply GND

Sensor power supply GND

Sensor power supply 24 V DC

Sensor power supply 24 V DC

Trigger input for start-up bypass

External trigger signal

Bridge fitted: start-up bypass triggered by switching on the power supply

Relay output

External rectangular signal

Galvanically isolated input

9NAMUR L+

NAMUR L-8

73

2

1

15

14

13

6

COM

NC

NO

4L+

5L-

16L1 (230 V)

17L1 (115 V)

18N

12

11

10

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 22: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1100 Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Spec

ial F

unct

ions

Dev

ices

Frequency to Voltage/Curent

• Limit frequency 40 kHz• Voltage or current ouptput• Incrementing output

(Spacing factor 1 ... 9999)• Multi-range power pack• 2-, 3-, 4-wire and NAMUR sensors as

well as rotary encoder connectable• Auxiliary power output for sensors• Connection via Power Rail• Period measurement• Display: Input in Hz or 1/min, output in V

or mA• adjustable updating of indication

(0,001 ... 2,5 s)

Dimensions

Electrical connection

KFU8-FSSP-1.DSupplyRated voltage 196 ... 264 V AC ; 98 ... 132 V AC; 47 ... 63 Hz

20.4 ... 27.6 V DCPower consumption AC: < 5 VA

DC: < 5 WIndicators/operating meansType 4-digit 7-segment display, red, 7 mm digit heightDisplay interval 0.002 ... 9999 Hz or

0,01 ... 9999 min-1

Parameter assignment keypad-driven menuInput 1Connectable sensor types NAMUR sensors according to DIN EN 60947-5-6Open loop voltage 8.2 V DCShort-circuit current 6.5 mASwitching point 1.2 ... 2.1 mA Switching hysteresis approx. 0.2 mAInput 2Connectable sensor types 2-, 3- or 4-wire proximity switches and incremental rotary encoderSensor supply 19 ... 28 V DC non-stabilised; ≤ 30 mA short-circuit proofSwitching point high: 16 ... 30 V DC; max.10 mA; Ri ≅ 3 kOhm

low: 0 ... 6 V DCOutputAnalogue voltage output 0 ... 10 V DC; 2 ... 10 V DC; 30 mA max.; resolution: 12 mV; Ri ≥ 330 Ω (terminal

5+, 6-)Analogue current output 0 ... 20 mA; 4 ... 20 mA; resolution: 25 µA; Ri ≤ 600 Ω (terminal 4-, 5+)Digital incrementing ≥ (Ub -3 V), 20 mA, short-circuit proof (Terminals 1-, 2+)

with frequency division Fin /1 ... Fin /9999Transfer characteristicsInput frequency ≤ 40000 Hz, pulse pause/pulse length: ≥ 12 µsAmbient conditionsAmbient temperature -25 ... 60 °C (248 ... 333 K)Mechanical specificationsProtection degree IP20Connection coded, removable terminals , max. core cross-section 0.34 ... 2.5 mm2

Mode

Output Drehzahlwächter Speed monitor

Enter

+

1 2 3 4 5 6

13 14 15 16 17 187 8 9 10 11 12

PEPPERL+FUCHS GERMANY

Control keys

7-segment-display

107

93

115

NAMUR L+

NAMUR L–

L+

L–

L+

L–

L+

L–

L+

L–

L+

L–

L+

L–

L+

L–

N

L1 (230 V)

L1 (115 V)

9

8

7

15

14

13

11

12

16

18

17

DC

DC

D

A

5I+ / U+

I–

U–

4

6

2

1

3

10

V

mA

Ri ≤ 600 Ω

13, 14157

13147, 15

13, 14157

1314

8

9

8

9

7, 15Ri ≥ 330 Ω

Power supply 115 V AC

Power supply 24 V DC

Sensor power supply 24 V

Power supply 230 V AC

Encoder, push-pull

Encoder, push-pull

DC-3-wire sensor, PNP

DC-3-wire sensor, NPN

NAMUR Sensor

NAMUR Encoder

Galvanically isolated input for PNP- and NPN- output circuits

Sensor power supply GND

Sensor power supply GND

Pulse output

Not connected

Not connected

Technical Specifications

• Limit frequency 40 kHz• Voltage or current ouptput• Multi-range power pack• 2-, 3-, 4-wire and NAMUR sensors as

well as rotary encoder connectable• Auxiliary power output for sensors• Connection via Power Rail• Period measurement• Display: Input in Hz or 1/min,

output in V or mA• Adjustable updating of indication

(0,001...2,5 s)

• Limit frequency 40 kHz• Voltage or current ouptput• Incrementing output

(Spacing factor 1 ... 9999)• Multi-range power pack• 2-, 3-, 4-wire and NAMUR sensors as

well as rotary encoder connectable• Auxiliary power output for sensors• Connection via Power Rail• Period measurement• Display: Input in Hz or 1/min, output in V

or mA• adjustable updating of indication

(0,001 ... 2,5 s)

Dimensions

Electrical connection

KFU8-FSSP-1.DSupplyRated voltage 196 ... 264 V AC ; 98 ... 132 V AC; 47 ... 63 Hz

20.4 ... 27.6 V DCPower consumption AC: < 5 VA

DC: < 5 WIndicators/operating meansType 4-digit 7-segment display, red, 7 mm digit heightDisplay interval 0.002 ... 9999 Hz or

0,01 ... 9999 min-1

Parameter assignment keypad-driven menuInput 1Connectable sensor types NAMUR sensors according to DIN EN 60947-5-6Open loop voltage 8.2 V DCShort-circuit current 6.5 mASwitching point 1.2 ... 2.1 mA Switching hysteresis approx. 0.2 mAInput 2Connectable sensor types 2-, 3- or 4-wire proximity switches and incremental rotary encoderSensor supply 19 ... 28 V DC non-stabilised; ≤ 30 mA short-circuit proofSwitching point high: 16 ... 30 V DC; max.10 mA; Ri ≅ 3 kOhm

low: 0 ... 6 V DCOutputAnalogue voltage output 0 ... 10 V DC; 2 ... 10 V DC; 30 mA max.; resolution: 12 mV; Ri ≥ 330 Ω (terminal

5+, 6-)Analogue current output 0 ... 20 mA; 4 ... 20 mA; resolution: 25 µA; Ri ≤ 600 Ω (terminal 4-, 5+)Digital incrementing ≥ (Ub -3 V), 20 mA, short-circuit proof (Terminals 1-, 2+)

with frequency division Fin /1 ... Fin /9999Transfer characteristicsInput frequency ≤ 40000 Hz, pulse pause/pulse length: ≥ 12 µsAmbient conditionsAmbient temperature -25 ... 60 °C (248 ... 333 K)Mechanical specificationsProtection degree IP20Connection coded, removable terminals , max. core cross-section 0.34 ... 2.5 mm2

Mode

Output Drehzahlwächter Speed monitor

Enter

+

1 2 3 4 5 6

13 14 15 16 17 187 8 9 10 11 12

PEPPERL+FUCHS GERMANY

Control keys

7-segment-display

107

93

115

NAMUR L+

NAMUR L–

L+

L–

L+

L–

L+

L–

L+

L–

L+

L–

L+

L–

L+

L–

N

L1 (230 V)

L1 (115 V)

9

8

7

15

14

13

11

12

16

18

17

DC

DC

D

A

5I+ / U+

I–

U–

4

6

2

1

3

10

V

mA

Ri ≤ 600 Ω

13, 14157

13147, 15

13, 14157

1314

8

9

8

9

7, 15Ri ≥ 330 Ω

Power supply 115 V AC

Power supply 24 V DC

Sensor power supply 24 V

Power supply 230 V AC

Encoder, push-pull

Encoder, push-pull

DC-3-wire sensor, PNP

DC-3-wire sensor, NPN

NAMUR Sensor

NAMUR Encoder

Galvanically isolated input for PNP- and NPN- output circuits

Sensor power supply GND

Sensor power supply GND

Pulse output

Not connected

Not connected

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 23: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1101Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Special Functions Devices

Wiring Diagrams

Terminal Connection

Dimensions

• Limit frequency 40 kHz• Voltage or current ouptput• Incrementing output

(Spacing factor 1 ... 9999)• Multi-range power pack• 2-, 3-, 4-wire and NAMUR sensors as

well as rotary encoder connectable• Auxiliary power output for sensors• Connection via Power Rail• Period measurement• Display: Input in Hz or 1/min, output in V

or mA• adjustable updating of indication

(0,001 ... 2,5 s)

Dimensions

Electrical connection

KFU8-FSSP-1.DSupplyRated voltage 196 ... 264 V AC ; 98 ... 132 V AC; 47 ... 63 Hz

20.4 ... 27.6 V DCPower consumption AC: < 5 VA

DC: < 5 WIndicators/operating meansType 4-digit 7-segment display, red, 7 mm digit heightDisplay interval 0.002 ... 9999 Hz or

0,01 ... 9999 min-1

Parameter assignment keypad-driven menuInput 1Connectable sensor types NAMUR sensors according to DIN EN 60947-5-6Open loop voltage 8.2 V DCShort-circuit current 6.5 mASwitching point 1.2 ... 2.1 mA Switching hysteresis approx. 0.2 mAInput 2Connectable sensor types 2-, 3- or 4-wire proximity switches and incremental rotary encoderSensor supply 19 ... 28 V DC non-stabilised; ≤ 30 mA short-circuit proofSwitching point high: 16 ... 30 V DC; max.10 mA; Ri ≅ 3 kOhm

low: 0 ... 6 V DCOutputAnalogue voltage output 0 ... 10 V DC; 2 ... 10 V DC; 30 mA max.; resolution: 12 mV; Ri ≥ 330 Ω (terminal

5+, 6-)Analogue current output 0 ... 20 mA; 4 ... 20 mA; resolution: 25 µA; Ri ≤ 600 Ω (terminal 4-, 5+)Digital incrementing ≥ (Ub -3 V), 20 mA, short-circuit proof (Terminals 1-, 2+)

with frequency division Fin /1 ... Fin /9999Transfer characteristicsInput frequency ≤ 40000 Hz, pulse pause/pulse length: ≥ 12 µsAmbient conditionsAmbient temperature -25 ... 60 °C (248 ... 333 K)Mechanical specificationsProtection degree IP20Connection coded, removable terminals , max. core cross-section 0.34 ... 2.5 mm2

Mode

Output Drehzahlwächter Speed monitor

Enter

+

1 2 3 4 5 6

13 14 15 16 17 187 8 9 10 11 12

PEPPERL+FUCHS GERMANY

Control keys

7-segment-display

107

93

115

NAMUR L+

NAMUR L–

L+

L–

L+

L–

L+

L–

L+

L–

L+

L–

L+

L–

L+

L–

N

L1 (230 V)

L1 (115 V)

9

8

7

15

14

13

11

12

16

18

17

DC

DC

D

A

5I+ / U+

I–

U–

4

6

2

1

3

10

V

mA

Ri ≤ 600 Ω

13, 14157

13147, 15

13, 14157

1314

8

9

8

9

7, 15Ri ≥ 330 Ω

Power supply 115 V AC

Power supply 24 V DC

Sensor power supply 24 V

Power supply 230 V AC

Encoder, push-pull

Encoder, push-pull

DC-3-wire sensor, PNP

DC-3-wire sensor, NPN

NAMUR Sensor

NAMUR Encoder

Galvanically isolated input for PNP- and NPN- output circuits

Sensor power supply GND

Sensor power supply GND

Pulse output

Not connected

Not connected

• Limit frequency 40 kHz• Voltage or current ouptput• Incrementing output

(Spacing factor 1 ... 9999)• Multi-range power pack• 2-, 3-, 4-wire and NAMUR sensors as

well as rotary encoder connectable• Auxiliary power output for sensors• Connection via Power Rail• Period measurement• Display: Input in Hz or 1/min, output in V

or mA• adjustable updating of indication

(0,001 ... 2,5 s)

Dimensions

Electrical connection

KFU8-FSSP-1.DSupplyRated voltage 196 ... 264 V AC ; 98 ... 132 V AC; 47 ... 63 Hz

20.4 ... 27.6 V DCPower consumption AC: < 5 VA

DC: < 5 WIndicators/operating meansType 4-digit 7-segment display, red, 7 mm digit heightDisplay interval 0.002 ... 9999 Hz or

0,01 ... 9999 min-1

Parameter assignment keypad-driven menuInput 1Connectable sensor types NAMUR sensors according to DIN EN 60947-5-6Open loop voltage 8.2 V DCShort-circuit current 6.5 mASwitching point 1.2 ... 2.1 mA Switching hysteresis approx. 0.2 mAInput 2Connectable sensor types 2-, 3- or 4-wire proximity switches and incremental rotary encoderSensor supply 19 ... 28 V DC non-stabilised; ≤ 30 mA short-circuit proofSwitching point high: 16 ... 30 V DC; max.10 mA; Ri ≅ 3 kOhm

low: 0 ... 6 V DCOutputAnalogue voltage output 0 ... 10 V DC; 2 ... 10 V DC; 30 mA max.; resolution: 12 mV; Ri ≥ 330 Ω (terminal

5+, 6-)Analogue current output 0 ... 20 mA; 4 ... 20 mA; resolution: 25 µA; Ri ≤ 600 Ω (terminal 4-, 5+)Digital incrementing ≥ (Ub -3 V), 20 mA, short-circuit proof (Terminals 1-, 2+)

with frequency division Fin /1 ... Fin /9999Transfer characteristicsInput frequency ≤ 40000 Hz, pulse pause/pulse length: ≥ 12 µsAmbient conditionsAmbient temperature -25 ... 60 °C (248 ... 333 K)Mechanical specificationsProtection degree IP20Connection coded, removable terminals , max. core cross-section 0.34 ... 2.5 mm2

Mode

Output Drehzahlwächter Speed monitor

Enter

+

1 2 3 4 5 6

13 14 15 16 17 187 8 9 10 11 12

PEPPERL+FUCHS GERMANY

Control keys

7-segment-display

107

93

115

NAMUR L+

NAMUR L–

L+

L–

L+

L–

L+

L–

L+

L–

L+

L–

L+

L–

L+

L–

N

L1 (230 V)

L1 (115 V)

9

8

7

15

14

13

11

12

16

18

17

DC

DC

D

A

5I+ / U+

I–

U–

4

6

2

1

3

10

V

mA

Ri ≤ 600 Ω

13, 14157

13147, 15

13, 14157

1314

8

9

8

9

7, 15Ri ≥ 330 Ω

Power supply 115 V AC

Power supply 24 V DC

Sensor power supply 24 V

Power supply 230 V AC

Encoder, push-pull

Encoder, push-pull

DC-3-wire sensor, PNP

DC-3-wire sensor, NPN

NAMUR Sensor

NAMUR Encoder

Galvanically isolated input for PNP- and NPN- output circuits

Sensor power supply GND

Sensor power supply GND

Pulse output

Not connected

Not connected

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 24: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1102 Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Spec

ial F

unct

ions

Dev

ices

• 1-channel standstill controller• Rotation direction detection or start-up

override selectable• 2 relay outputs• Input frequency ≤ 2 kHz• Diagnosis LEDs for rotation detection,

signal below the trip value, operating voltage and hardware error

• Simple setting of function and limiting frequency via DIP switch on the front side

• Plug-in terminals

7 8 9

10 11 12

1 2 34 5 6

13 14 15

1

2

S1S2S3

PWRCHKOUT

12

3

III

Front view

Switch S1:Cutoff frequency

Switch S2:Cutoff frequency

LED green:Power supply

Removable terminalsgreen

LED yellow:Relay output I

LED yellow:Relay output II

Switch S3:Start-up override/Rotation direction detectionLEDs flashing red:

Hardware error

Removable terminalsgreen

Electrical connection

KFD2-SR2-2.W.SMGeneral specificationsPre-selection singleProgramming via DIP switch and programmableSupplyRated voltage 20 ... 30 V DCPower consumption ≤ 1.5 WIndicators/operating meansLED green Operating voltageLED yellow switching stateLED red Hardware errorDIP-switch setting the configurationInputRated values acc. to EN 60947-5-6 (NAMUR)Switching point/Switching hyste-resis

x ≤ 1,2 mA oder x ≥ 2,1 mA / approx. 0.9 mA

Control input sensor power supply approx. 8.2 V, impedance 1.2 kΩLead monitoring not availablePulse duration > 200 µs for standstill monitoring,

> 250 µs for rotation direction detecionOutputRelay 2 changeover contactsContact loading 253 V AC/2 A /cos φ > 0.7; 40 V DC/2 A resistive load;Energized/de-energized delay approx. 20 ms / approx. 20 msMechanical life 5 x 106 switching cyclesTrip value for standstill monitoring:

0.1 Hz; 0.5 Hz; 2 Hz; 10 Hzadjustable via DIP switch (S1 and S2)

Transfer characteristicsAccuracy ± 5 %Start-up override 5 seconds or 20 seconds, programmableFrequency range ≤ 2 kHzRotation direction detection 90° phase difference between pulse input signal 1 and 2, overlapping ≥ 125 µsElectrical isolationInput/output safe electrical isolation per EN 50178, voltage peak value 253 VInput/power supply safe electrical isolation per EN 50178, voltage peak value 253 VOutput/power supply safe electrical isolation per EN 50178, voltage peak value 253 VOutput/output basic insulation according to DIN EN 50178, rated insulation voltage 253 VeffAmbient conditionsAmbient temperature -20 ... 60 °C (253 ... 333 K)Mechanical specificationsProtection degree IP20Connection plug-in terminalsMass approx. 150 gDimensions 20 mm x 118 mm x 115 mm

Input I Input II

green

Output I Output II Power supply

yellow yellow

red

external supply

3-wirepnp/push-pull

external supply

3-wirepnp/push-pull

Start-up override

20 sec.

5 sec.Jumper (switch-on trigger)or trigger signal

Contact(not bouncing)

Contact(not bouncing)

+ -

1+ 3-

+ 24 V- 24 V

3-2+

-+Q

1+ 3-

2+

3-1+

+ 24 V- 24 V

6-

-+Q

4+ 6-

6-4+

6-4+

6-5+

4+ 6-5+

14 157 8 9 10 11 12

NAMUR NAMUR

S1 S2 S3

Zero Speed Monitor

Technical Specifications

• 1-channel standstill controller• Rotation direction detection or

start-up override selectable• 2 relay outputs• Input frequency ≤ 2 kHz• Diagnosis LEDs for rotation detection,

signal below the trip value, operating voltage and hardware error

• Simple setting of function and limiting frequency via DIP switch on the front side

• Plug-in terminals• 1-channel standstill controller• Rotation direction detection or start-up

override selectable• 2 relay outputs• Input frequency ≤ 2 kHz• Diagnosis LEDs for rotation detection,

signal below the trip value, operating voltage and hardware error

• Simple setting of function and limiting frequency via DIP switch on the front side

• Plug-in terminals

7 8 9

10 11 12

1 2 34 5 6

13 14 15

1

2

S1S2S3

PWRCHKOUT

12

3

III

Front view

Switch S1:Cutoff frequency

Switch S2:Cutoff frequency

LED green:Power supply

Removable terminalsgreen

LED yellow:Relay output I

LED yellow:Relay output II

Switch S3:Start-up override/Rotation direction detectionLEDs flashing red:

Hardware error

Removable terminalsgreen

Electrical connection

KFD2-SR2-2.W.SMGeneral specificationsPre-selection singleProgramming via DIP switch and programmableSupplyRated voltage 20 ... 30 V DCPower consumption ≤ 1.5 WIndicators/operating meansLED green Operating voltageLED yellow switching stateLED red Hardware errorDIP-switch setting the configurationInputRated values acc. to EN 60947-5-6 (NAMUR)Switching point/Switching hyste-resis

x ≤ 1,2 mA oder x ≥ 2,1 mA / approx. 0.9 mA

Control input sensor power supply approx. 8.2 V, impedance 1.2 kΩLead monitoring not availablePulse duration > 200 µs for standstill monitoring,

> 250 µs for rotation direction detecionOutputRelay 2 changeover contactsContact loading 253 V AC/2 A /cos φ > 0.7; 40 V DC/2 A resistive load;Energized/de-energized delay approx. 20 ms / approx. 20 msMechanical life 5 x 106 switching cyclesTrip value for standstill monitoring:

0.1 Hz; 0.5 Hz; 2 Hz; 10 Hzadjustable via DIP switch (S1 and S2)

Transfer characteristicsAccuracy ± 5 %Start-up override 5 seconds or 20 seconds, programmableFrequency range ≤ 2 kHzRotation direction detection 90° phase difference between pulse input signal 1 and 2, overlapping ≥ 125 µsElectrical isolationInput/output safe electrical isolation per EN 50178, voltage peak value 253 VInput/power supply safe electrical isolation per EN 50178, voltage peak value 253 VOutput/power supply safe electrical isolation per EN 50178, voltage peak value 253 VOutput/output basic insulation according to DIN EN 50178, rated insulation voltage 253 VeffAmbient conditionsAmbient temperature -20 ... 60 °C (253 ... 333 K)Mechanical specificationsProtection degree IP20Connection plug-in terminalsMass approx. 150 gDimensions 20 mm x 118 mm x 115 mm

Input I Input II

green

Output I Output II Power supply

yellow yellow

red

external supply

3-wirepnp/push-pull

external supply

3-wirepnp/push-pull

Start-up override

20 sec.

5 sec.Jumper (switch-on trigger)or trigger signal

Contact(not bouncing)

Contact(not bouncing)

+ -

1+ 3-

+ 24 V- 24 V

3-2+

-+Q

1+ 3-

2+

3-1+

+ 24 V- 24 V

6-

-+Q

4+ 6-

6-4+

6-4+

6-5+

4+ 6-5+

14 157 8 9 10 11 12

NAMUR NAMUR

S1 S2 S3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 25: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1103Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Special Functions Devices

• 1-channel standstill controller• Rotation direction detection or start-up

override selectable• 2 relay outputs• Input frequency ≤ 2 kHz• Diagnosis LEDs for rotation detection,

signal below the trip value, operating voltage and hardware error

• Simple setting of function and limiting frequency via DIP switch on the front side

• Plug-in terminals

7 8 9

10 11 12

1 2 34 5 6

13 14 15

1

2

S1S2S3

PWRCHKOUT

12

3

III

Front view

Switch S1:Cutoff frequency

Switch S2:Cutoff frequency

LED green:Power supply

Removable terminalsgreen

LED yellow:Relay output I

LED yellow:Relay output II

Switch S3:Start-up override/Rotation direction detectionLEDs flashing red:

Hardware error

Removable terminalsgreen

Electrical connection

KFD2-SR2-2.W.SMGeneral specificationsPre-selection singleProgramming via DIP switch and programmableSupplyRated voltage 20 ... 30 V DCPower consumption ≤ 1.5 WIndicators/operating meansLED green Operating voltageLED yellow switching stateLED red Hardware errorDIP-switch setting the configurationInputRated values acc. to EN 60947-5-6 (NAMUR)Switching point/Switching hyste-resis

x ≤ 1,2 mA oder x ≥ 2,1 mA / approx. 0.9 mA

Control input sensor power supply approx. 8.2 V, impedance 1.2 kΩLead monitoring not availablePulse duration > 200 µs for standstill monitoring,

> 250 µs for rotation direction detecionOutputRelay 2 changeover contactsContact loading 253 V AC/2 A /cos φ > 0.7; 40 V DC/2 A resistive load;Energized/de-energized delay approx. 20 ms / approx. 20 msMechanical life 5 x 106 switching cyclesTrip value for standstill monitoring:

0.1 Hz; 0.5 Hz; 2 Hz; 10 Hzadjustable via DIP switch (S1 and S2)

Transfer characteristicsAccuracy ± 5 %Start-up override 5 seconds or 20 seconds, programmableFrequency range ≤ 2 kHzRotation direction detection 90° phase difference between pulse input signal 1 and 2, overlapping ≥ 125 µsElectrical isolationInput/output safe electrical isolation per EN 50178, voltage peak value 253 VInput/power supply safe electrical isolation per EN 50178, voltage peak value 253 VOutput/power supply safe electrical isolation per EN 50178, voltage peak value 253 VOutput/output basic insulation according to DIN EN 50178, rated insulation voltage 253 VeffAmbient conditionsAmbient temperature -20 ... 60 °C (253 ... 333 K)Mechanical specificationsProtection degree IP20Connection plug-in terminalsMass approx. 150 gDimensions 20 mm x 118 mm x 115 mm

Input I Input II

green

Output I Output II Power supply

yellow yellow

red

external supply

3-wirepnp/push-pull

external supply

3-wirepnp/push-pull

Start-up override

20 sec.

5 sec.Jumper (switch-on trigger)or trigger signal

Contact(not bouncing)

Contact(not bouncing)

+ -

1+ 3-

+ 24 V- 24 V

3-2+

-+Q

1+ 3-

2+

3-1+

+ 24 V- 24 V

6-

-+Q

4+ 6-

6-4+

6-4+

6-5+

4+ 6-5+

14 157 8 9 10 11 12

NAMUR NAMUR

S1 S2 S3

Wiring Diagrams

Terminal Connection

Dimensions

• 1-channel standstill controller• Rotation direction detection or start-up

override selectable• 2 relay outputs• Input frequency ≤ 2 kHz• Diagnosis LEDs for rotation detection,

signal below the trip value, operating voltage and hardware error

• Simple setting of function and limiting frequency via DIP switch on the front side

• Plug-in terminals

7 8 9

10 11 12

1 2 34 5 6

13 14 15

1

2

S1S2S3

PWRCHKOUT

12

3

III

Front view

Switch S1:Cutoff frequency

Switch S2:Cutoff frequency

LED green:Power supply

Removable terminalsgreen

LED yellow:Relay output I

LED yellow:Relay output II

Switch S3:Start-up override/Rotation direction detectionLEDs flashing red:

Hardware error

Removable terminalsgreen

Electrical connection

KFD2-SR2-2.W.SMGeneral specificationsPre-selection singleProgramming via DIP switch and programmableSupplyRated voltage 20 ... 30 V DCPower consumption ≤ 1.5 WIndicators/operating meansLED green Operating voltageLED yellow switching stateLED red Hardware errorDIP-switch setting the configurationInputRated values acc. to EN 60947-5-6 (NAMUR)Switching point/Switching hyste-resis

x ≤ 1,2 mA oder x ≥ 2,1 mA / approx. 0.9 mA

Control input sensor power supply approx. 8.2 V, impedance 1.2 kΩLead monitoring not availablePulse duration > 200 µs for standstill monitoring,

> 250 µs for rotation direction detecionOutputRelay 2 changeover contactsContact loading 253 V AC/2 A /cos φ > 0.7; 40 V DC/2 A resistive load;Energized/de-energized delay approx. 20 ms / approx. 20 msMechanical life 5 x 106 switching cyclesTrip value for standstill monitoring:

0.1 Hz; 0.5 Hz; 2 Hz; 10 Hzadjustable via DIP switch (S1 and S2)

Transfer characteristicsAccuracy ± 5 %Start-up override 5 seconds or 20 seconds, programmableFrequency range ≤ 2 kHzRotation direction detection 90° phase difference between pulse input signal 1 and 2, overlapping ≥ 125 µsElectrical isolationInput/output safe electrical isolation per EN 50178, voltage peak value 253 VInput/power supply safe electrical isolation per EN 50178, voltage peak value 253 VOutput/power supply safe electrical isolation per EN 50178, voltage peak value 253 VOutput/output basic insulation according to DIN EN 50178, rated insulation voltage 253 VeffAmbient conditionsAmbient temperature -20 ... 60 °C (253 ... 333 K)Mechanical specificationsProtection degree IP20Connection plug-in terminalsMass approx. 150 gDimensions 20 mm x 118 mm x 115 mm

Input I Input II

green

Output I Output II Power supply

yellow yellow

red

external supply

3-wirepnp/push-pull

external supply

3-wirepnp/push-pull

Start-up override

20 sec.

5 sec.Jumper (switch-on trigger)or trigger signal

Contact(not bouncing)

Contact(not bouncing)

+ -

1+ 3-

+ 24 V- 24 V

3-2+

-+Q

1+ 3-

2+

3-1+

+ 24 V- 24 V

6-

-+Q

4+ 6-

6-4+

6-4+

6-5+

4+ 6-5+

14 157 8 9 10 11 12

NAMUR NAMUR

S1 S2 S3

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Page 26: Amplifiers, Counters, Timers & Controlsstevenengineering.com/Tech_Support/PDFs/32NASFD.pdf · DA5-IU-2K-C DA5-IU-2K-V General specifications Pre-selection 2-fold Data storage 106

1104 Singapore: +65 6779 [email protected]

USA: +1 330 486 [email protected]

Germany: +49 621 [email protected]

Pepperl+Fuchs Groupwww.pepperl-fuchs.com

Subject to modifications without notice Copyright Pepperl+Fuchs

Special Functions Devices

Spec

ial F

unct

ions

Dev

ices

Notes