2
When it comes to flow...we’re instrumental. 4 Inductive Slot Sensor The alarm mechanism in this flowmeter is an inductive slot sensor. It is a 2-wire, DC, low current device designed to be used with a switch isolator / barrier. The operating temperature range for this sensor is -13°F to 158°F (-25°C to 70°C). Note: We can supply the isolator / barrier upon request, but the user must provide the power supply voltage. DESCRIPTION Metering Tube 316L SS Internal Components 316L SS, Hastelloy® C-276 Case and Side Cover Die cast aluminum Fitting Material / Type 316L SS ¼” FNPT, horizontal Scale Cover 304 SS frame Annealed glass window O-Ring EPR, Buna N, Kalrez® PERFORMANCE Flow Capacities Water 0.6 to 25 GPH (2.4 to 95 LPH) Air 1 to 120 SCFH (28.3 to 3,400 SLPH) Accuracy ± 5% of full scale flow Repeatability 1 % Turndown 10:1 Ambient Temperature -40°F to 125°F (-40°C to 52°C) Maximum Temperature O-Ring Maximum Temperature EPR Buna N Viton Kalrez No O-ring 300° F 275° F 350° F 400° F 400° F (149° C) (135° C) (177° C) (204° C) (204° C) Maximum Pressure Valve models — 1,500 psig Non-valve models — 4,000 psig OPTIONS Alarm Single, Inductive Slot Sensor Certified Calibrations ISA RP 16.6 Control Valves Inlet and outlet CRNs All Canadian provinces Rear Mounting Bracket 304 SS Scales Any volumetric unit All 316L stainless steel construction makes this meter suitable for low-flow, high-pressure applications. 7100 Series Stainless Steel Tube ALARM OPTIONS: 7100 with Inductive Slot Sensor New! Flanged Connection and Threaded Fittings For Easy Replacement

All 316L stainless steel construction makes this meter ... · PDF fileFlow Capacities Water 0.6 to 25 GPH ... METER TUBE CASE ASSEMBLY SCREW Pressure and temperature ratings are based

Embed Size (px)

Citation preview

When it comes to flow...we’re instrumental.4

Inductive Slot Sensor

The alarm mechanism in this flowmeter is an inductive slot sensor. It is a 2-wire, DC, low current device designed to be used with a switch isolator / barrier.

The operating temperature range for this sensor is -13°F to 158°F (-25°C to 70°C).

Note: We can supply the isolator / barrier upon request, but the user must provide the power supply voltage.

DESCRIPTION

Metering Tube 316L SS

Internal Components 316L SS, Hastelloy® C-276

Case and Side Cover Die cast aluminum

Fitting Material / Type 316L SS¼” FNPT, horizontal

Scale Cover 304 SS frame Annealed glass window

O-Ring EPR, Buna N, Kalrez®

PERFORMANCE

Flow Capacities Water 0.6 to 25 GPH (2.4 to 95 LPH)

Air 1 to 120 SCFH (28.3 to 3,400 SLPH)

Accuracy ± 5% of full scale flow

Repeatability 1 %

Turndown 10:1

Ambient Temperature -40°F to 125°F (-40°C to 52°C)

Maximum Temperature O-Ring Maximum Temperature

EPRBuna NViton Kalrez No O-ring

300° F275° F350° F400° F400° F

(149° C)(135° C)(177° C)(204° C)(204° C)

Maximum Pressure Valve models — 1,500 psigNon-valve models — 4,000 psig

OPTIONS

Alarm Single, Inductive Slot Sensor

Certified Calibrations ISA RP 16.6

Control Valves Inlet and outlet

CRNs All Canadian provinces

Rear Mounting Bracket 304 SS

Scales Any volumetric unit

All 316L stainless steel construction makes this meter suitable for low-flow, high-pressure applications.

7100 Series Stainless Steel Tube

ALARM OPTIONS:

7100 with Inductive Slot Sensor

New!Flanged

Connectionand Threaded

Fittings For Easy

Replacement

(714) 891-0008 • www.kinginstrumentco.comWhen it comes to flow...we’re instrumental. 5

DIMENSIONS (INCHES)

ORDERING: Use the following guide to determine the specific product number you require.

7100 Series Specifications Stainless Steel Tube

Order Number

Full Scale Flow WaterGPH

Full Scale Flow Water

LPH

02W .6 2.4

04W 1.2 4.5

06W 2.8 10.5

08W 5.5 20

10W 12 45

12W 25 95

Order Number

Full Scale Flow AirSCFH

Full Scale Flow AirSLPH

00A* 1.0 28.3

01A 2.5 70

03A 5.5 155

05A 13 360

07A 24 680

09A 55 1550

11A 120 3400

* The No O-ring option is for non-valve meters only

7 1 0

Meter Series

Material of Construction

O-ring Material

Scale Valve Options

Optional Alarm

Order Number

Flange Options

316L SS - 1 No O-ring* - 0 Millimeter - 1 Inlet 316L SS - 1 No Alarm - 0 See Spec. 1/2” 150# RF Flange Welded AHST® C-276 - 2 EPR - 1 GPH Water - 2 Outlet 316L SS - 2 With Alarm - A table above 1” 150# RF Flange Welded B

Buna-N - 2 LPH Water - 3 No Valve - 3 1/2” 300# RF Flange Welded CViton® - 3 SCFH Air@STP - 4 Inlet HST® C-276 - 4 1” 300# RF Flange Welded DKalrez® - 4 SLPH Air@STP - 5 Outlet HST® C-276 - 5 1/2” 150# RF Flange Quick Connect E

Non standard - 6 1” 150# RF Flange Quick Connect F1/2” 300# RF Flange Quick Connect G1” 300# RF Flange Quick Connect H

(FULL OPEN)

1

2

10-32 THREADED PANEL MOUNTING HOLES (2 PLACES)

10-32 THREADED HOLE FOR OPTIONAL MOUNTING BRACKET (2 PLACES)

(TYP.)(TYP.)

2

2

1

1

3 OPTIONAL ALARM CONNECTION (BACKSIDE OF CASE)

3

3

4 FLANGE CONNECTION (12" / 3 4" / 1" - 150# FLANGES / QUICK DISCONNECT OPTIONAL)

4

3

OPTIONALQUICKDISCONNECT

OPTIONALQUICKDISCONNECT

* This meter has a titanium float

TOP PLUG

OUTLET FLOAT STOP

FLOAT

METER TUBE

CASE ASSEMBLY

SCREW

Pressure and temperature ratings are based on a study of the engineeringdata for particular materials used in construction and on the design ofindividual models. This information is supplemented by destructive testresults. Meters with stainless enclosures must never be operated withoutshields securely in place. Meters exposed to difficult environments suchas those created by certain chemicals, excessive vibration or other stressinducing factors could fail at or below the suggested maximums. Neveroperate meters above pressure and temperature maximums. It is stronglyrecommended that all meter installations utilize an appropriate pressurerelief valve and/or rupture disc. The pressure settings and locations ofthese devices should be such that meters cannot be over pressurized.Meter failure could result in damage to equipment and serious personalinjury. Always use suitable safety gear, including OSHA approved eyeprotection when working around meters in service. We are happy to passalong chemical compatibility information that has been published by themanufacturer's of raw materials used in our products; however, thisinformation should not be construed as a recommendation made by KingInstrument Company, Inc. for a specific application.

Carefully remove the flowmeter from piping system. Remove the threadedoutlet plug and withdraw the float from the top. All necessary instrumentcomponents are now fully accessible for cleaning with a bottle brush andappropriate mild soap solution*. Before the meter is reassembled, inspectall parts for damage. O-rings should be replaced during metermaintenance and cleaning.To reassemble, carefully guide the magnetic float back into the tube.Reinstall and tighten top plug in appropriate port. Reinstall the instrumentinto the plumbing system after removing the old teflon tape (with a wirebrush) and replacing with fresh teflon tape.*Do not use cleaning agents that will damage float, tube or o-rings.Meters should be cleaned with a mild soap solution. This will be aneffective cleaner of rust stains. Caution must be used so that materials ofconstruction are not damaged by cleaning solutions. Hard water depositscan be removed with 5% acetic acid solution (vinegar).

7100 meters that require repair should be sent to the factory. Please callfor a Return Merchandise Authorization (RMA) number and returninstructions.

-O-rings should be replaced if meter is disassembled after it has been inservice.-Serious property damage and great personal injury could occur as theresult of a meter misused or used in an unsuitable application.

1) Inspect meter for damage that may have occurred during shipping. Reportany damage to the container to the freight carrier immediately.

This is important information. Read it carefully beforebeginning work.

2) Make sure your pressure, temperature, fluid and other requirements arecompatible with the meter including o-rings (where applicable).3) Select a suitable location for installation to prevent excess stress on themeter which may result from:

a) Misaligned pipe.b) The weight of related plumbing.c) "Water Hammer" which is most likely to occur when flow is suddenlystopped as with quick closing solenoid operated valves. (If necessary, asurge chamber should be installed. This will also be useful in pressurestart-up situations.)d) Thermal expansion of liquid in a stagnated or valve isolated system.e) Instantaneous pressurization which will stress the meter and could resultin tube failure.

NOTE: In closed thermal transfer or cooling systems, install the meter in thecool side of the line to minimize meter expansion and contraction and possiblefluid leaks at the threaded connections.4) Handle the meter carefully during installation.

a) Use an appropriate amount of teflon tape on external pipe threads beforemaking connections. Do not use paste or stick type thread sealing products.

5) Install the meter vertically with the inlet port at the bottom.6) Meters with stainless steel fittings will support several feet of pipe as longas significant vibration or stress resulting from misaligned pipe are not factors.

EPR 225 °FBuna-N

VitonKalrez

275 °F350 °F400 °F

Non-valveInlet / Outlet Valve

4,000 psig1,500 psig

Maximum Non-ShockPressure andTemperature O-Ring Temperature

Ambienttemperature

-40° F - 125° F

Viton and Kalrez are registered trademarks of DuPont Dow Elastomers.

O-Ring Material MaximumTemperature

ADDITIONALLY:-7100 Series meters are designed for vertical installation only. (Inlet at bottom,Outlet at top)-Do not remove or adjust the screws on the side of the indicator housing.These screws were positioned during factory calibration and represent thezero adjustment. If these screws are loosened and the indicator housing ismoved, the scale will be out of accuracy.Caution: Zero is factory set when meter is calibrated.DO NOT loosen screws that fasten indicator housing tometer body. If indicator housing is moved, the meterwill need to be calibrated.

2X

REAR CASE SCREW PLUG

SCALE PLATE

POINTER ASSEMBLY

POINTER ASSEMBLY

CASE COVER GASKET

CASE COVER

CASE COVER

2X

4X

FOLLOWER DISC/

METER TUBE ASSEMBLY

SCREW

SCREW

TOP PLUG

OUTLET FLOAT STOP

FLOAT

METER TUBE

CASE ASSEMBLY

ASSEMBLY SCREW

REAR CASE

METER TUBE

SCALE PLATE

POINTER ASSEMBLYPOINTER ASSEMBLY

CASE COVER

CASE COVER

CASE COVER

FOLLOWER DISC/

SCREW

SCREW

VALVE O-RING

VALVE ASSEMBLY

2X

2X

2X

4X

ASSEMBLYMETER TUBEFLANGE ASSEMBLY

SCREW PLUG

ASSEMBLYMETER TUBEFLANGE ASSEMBLY

GASKET

Maximum Non-ShockPressure andTemperature

300#psig

150#psig

Temp.°F

600225200540200300515180400

Ambienttemperature

-40° F - 125° F

EPR 225 °FBuna-N

VitonKalrez

275 °F350 °F400 °F

O-Ring TemperatureO-Ring Material Maximum

Temperature

Viton and Kalrez are registered trademarks of DuPont Dow Elastomers.

FNPT CONNECTION

FLANGED CONNECTION

1.813

5.475

4.000

.470

1.021.470

1.5004.505

.330

.330 1.400

.8101.625

2.180

1.900

10-32 THREADED HOLE FOR INSTALLING

(FULLY OPEN)

10-32 THREADED PANEL MOUNTING HOLES (2 PLACES)

THE OPTIONAL BACK MOUNTING BRACKET (2 PLACES)

(FULL OPEN)

1

2

10-32 THREADED PANEL MOUNTING HOLES (2 PLACES)

10-32 THREADED HOLE FOR OPTIONAL MOUNTING BRACKET (2 PLACES)

(TYP.)(TYP.)

2

2

1

1

3 OPTIONAL ALARM CONNECTION (BACKSIDE OF CASE)

3

3

4 FLANGE CONNECTION (12" / 3 4" / 1" - 150# FLANGES / QUICK DISCONNECT OPTIONAL)

4

3

OPTIONALQUICKDISCONNECT

OPTIONALQUICKDISCONNECT

1.840

4.040