Upload
others
View
9
Download
0
Embed Size (px)
Citation preview
Adaptable�Units 11% 4Total�Car�Spaces�allocated�to�units 41 Compliant�Solar�Access 100% 36Total�Car�Spaces�allocated�to�units�(GTGD) 20 Compliant�Cross�Ventilation 67% 24Visitor�Car�Spaces�(GTGD�@�1/7�Units) 5.1 Single�Orientated�South�Facing�Units 8% 3Total�Parking�Required�(GTGD) 25
Compliance�Table�D�(ADG)
Bed
Bath
Car�S
pace
s�Allo
cate
d�pe
r�uni
t
Car�S
pace
s�as�p
er�G
TGD
Adap
tabl
e
Nom
�Are
a�(M
2)
Min
�Req
uire
d�Ar
ea
Com
plie
s
Balc
ony�
Nom
�Are
a�(M
2)
Min
�Bal
cony
�Are
a�Re
quire
d�(M
2)
Com
plie
s
Sola
r�Acc
ess
Cros
s�Ven
tilat
ion
Sing
le�O
rient
ated
�Sou
th�F
acin
g
301 1 1 1 0.4 A 52 50 � NA 8 � � � 0302 1 1 1 0.4 54 50 � NA 8 � � 0303 S 1 1 0.4 41 40 � NA 4 � � 0304 2 2 1 0.7 75 75 � NA 10 � � � 0305 3 2 2 1.2 96 95 � NA 12 � � � 0306 2 2 1 0.7 76 75 � NA 10 � � 0307 2 2 1 0.7 76 75 � NA 10 � � � 0
8 4.5Nom�Res.�Area�this�level 470 460
401 2 2 1 0.7 76 75 � 14 10 � � � 0402 2 2 1 0.4 70 70 � 10 10 � � 0403 2 2 1 0.7 80 75 � 10 10 � � � 0404 1 1 1 0.4 51 50 � 8 8 � � 1405 2 2 1 0.7 80 75 � 10 10 � � � 0406 2 2 1 0.7 76 75 � 10 10 � � 0407 2 2 1 0.7 A 90 75 � 19 10 � � � 0
7 4.3 81Nom�Res.�Area�this�level 523 495
501 2 2 1 0.7 76 75 � 14 10 � � � 0502 2 2 1 0.4 70 70 � 10 10 � � 0503 2 2 1 0.7 80 75 � 10 10 � � � 0504 1 1 1 0.4 51 50 � 8 8 � � 1505 2 2 1 0.7 80 75 � 10 10 � � � 0506 2 2 1 0.7 76 75 � 10 10 � � 0507 2 2 2 0.7 A 90 75 � 19 10 � � � 0
8 4.3 81523 495
601 2 2 1 0.7 76 75 � 14 10 � � � 0602 2 2 1 0.4 70 70 � 10 10 � � 0603 2 2 1 0.7 80 75 � 10 10 � � � 0604 1 1 1 0.4 51 50 � 8 8 � � 1605 2 2 1 0.7 80 75 � 10 10 � � � 0606 2 2 1 0.7 76 75 � 10 10 � � 0607 2 2 2 0.7 A 90 75 � 19 10 � � � 0
8 4.3 81Nom�Res.�Area�this�level 523 495
701 2 2 1 0.7 102 75 � 24 10 � � � 0702 3 2 2 0.7 106 95 � 35 12 � � � 0703 2 2 1 1.2 104 75 � 24 10 � � � 0704 2 2 1 0.7 105 75 � 19 10 � � � 0
5 3.3 102Nom�Res.�Area�this�level 417 320
801 2 2 1 0.7 102 75 � 24 10 � � � 0802 3 2 2 0.7 106 95 � 35 10 � � � 0803 2 2 1 1.2 104 75 � 24 10 � � � 0804 2 2 1 0.7 105 75 � 19 10 � � � 0
5 3.3 102Nom�Res.�Area�this�level 417 320 447
Summary�of�Development�ProposalSite�Area�(M2) 1616
Unit�MixStudio 1 3%1�Bed 5 14%2�Bed 27 75%3�Bed 3 8%Units�Total 36 100%
Car�Parking�Total 50
Spaces/unit 1.39
Compliance�Table�A Proposed Com
plie
s
ControlFloor�Space�Ratio�(FSR)�/1 Not�Applicable 2.04Gross�Floor�Area�(GFA)�m2 Not�Applicable 3291Building�Height�(M) 20 Max �Car�Parking�Spaces�(ADG���GTGD) 25 Min 50 �Motorcycle�parking�(1/15�units) �Bicycle�parking��(GTGD�1/4�units) �
Compliance�Table�B Proposed Com
plie
s
Solar�Access 70% Min 36 100% �Cross�Ventilation 60% Min 24 67% �Adaptable�Units 10% Min 4 11% �Single�Orientated�South�Facing�Units 10% Max 3 8% �Communal�Open�Space�(ADG) 25% 404 m2 691 m2 �
Rooftop 428 m2Ground�Level�DSZ 263 m2
Requirement
Requirement
Basix Requirements Summary Multi Units Project Details
Mineow Pty Ltd 9, 9A, 11, 11A Alice Street SEVEN HILLS NSW 2147
Friday, May 12, 2017
Energy Target ’20 %’: 33 % Water Target ‘40%’: 42 %
Max Avg Heating Load (74.0 MJ/m2) 31.7 MJ/m2
Max Avg Cooling Load (70.0 MJ/m2) 45.5 MJ/m2
Basix Category Items Simulation Based on the Following Requirements
Fixtures All Shower Heads All toilet Flushing Systems All Kitchen Taps All Bathroom Taps
3 Star (>4.5Lt/Min but <= 6.0Lt/Min) 5 Star 5 Star 5 Star
Alternate Water Supply Minimum Rainwater Tank Size – N/ALT To collect run off from at least N/Am2 of roof area
Toilet Connection Laundry Connection Landscape Connection Reticulated Supply Pool Top Up
N/A N/A N/A N/A N/A
Energy
Hot water system : Gas Instantaneous with a minimum performance of 6 stars
Bathroom ventilation system : Individual fan, not ducted; manual switch on/off
Kitchen ventilation system : Individual fan, not ducted; manual switch on/off
Laundry ventilation system : Individual fan not ducted; manual switch on/off.
Cooling system : 1 Phase air-conditioning EER 3.0 - 3.5 in at least 1 living/bed area (zoned)
Heating system : 1 Phase air-conditioning EER 3.0 – 3.5 in at least 1 living/bed area (zoned)
Natural lighting: As per BASIX Artificial lighting: As per BASIX
Must install a gas cooktop and electric oven. Must install a fixed outdoor clothes drying line as part of the development
Landscaped Area � Common Area � 368m2
Car Park Areas � Two Levels � 39 Residential 7 Non Residential
External Walls (Medium) � Kingspan K18 35mm � R2.0 Bulk Insulation
Party Walls � CSR 4.2.4 � 4.2.4 Hebel Party Wall System
Internal Walls � Plasterboard on steel studs � Nil
Ceilings Internal � Concrete above plasterboard � Nil
Ceilings External � Concrete above plasterboard � R3.0 bulk insulation
Floors � Slab on ground � Suspended Slab
� Nil � Nil
Floor Coverings � Carpet � Tiles
� Bedrooms � Living / Wet Areas
Roof (Medium) � Suspended Concrete � Nil
Windows
� Aluminium framed single glazed clear to all windows and glass Doors unless noted otherwise
� Group ‘A’ ALM-001-01 (Awning, BiFold, Casement, Tilt’n’Turn): U-Value 6.70 or less and SHGC 0.57 +/- 5% Group ‘B’ ALM-002-01 (Double Hung, Fixed, Louvre, Sliding): U-Value 6.70 or less and SHGC 0.70 +/- 5%
Lighting: This dwelling has been rated with non-ventilated LED / Fluorescent downlights to insulated ceilings as per plan.
Note: Insulation specified must be installed in accordance with Part 3.12.1.1 of the BCA. Note: All exhaust fans to be fitted with self-closing dampers.