45
AEROTERME GAZ/AER Aeroterme

Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

  • Upload
    others

  • View
    6

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

Aeroterme

Page 2: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

Zabrele orizontale

H

Distanta aproximativa aruncare orizontala (m)

H/Putere 15kw 30kw 45kw 60kw 120kw

2,4m 10 18 21 25 36

3m 8,5 16 18 21 30

3,7m - 13 15 19 27

4,5m - - 14 16 24

6,1m - - - 14 21

Page 3: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

Ghidaj aer la 30 grade

H

Distanta aproximativa aruncare orizontala (m)

H/Putere 30kw 45kw 60kw 75kw 120kw

2,4m 20 23 26 30 38

3m 17 20 22 26 33

3,7m 15 17,5 20 24 30

4,5m - 15 16,5 20 26

6,1m - - 14 18 23

Page 4: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

Ghidaj aer la 60 grade

H

Distanta aproximativa aruncare orizontala (m)

H/Putere 30kw 45kw 60kw 75kw 120kw

2,4m 23 26 29 33 42

3m 20 23 25 29 36

3,7m 18 21 23 26 33

4,5m 15 17 20 22 29

6,1m - 16 18 20 26

Page 5: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

Zgomotul aerotermelor

• Creste cu diametrul ventilatorului

• Creste cu RPM ale ventilatorului

• Un numar mai mare de aeroterme mai • Un numar mai mare de aeroterme mai

mici sunt mai silentioase decat un numar

mai mic de aeroterme mai mari

• Creste cu apropierea de peretii din

spatele ventilatorului

Page 6: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AERAEROTERME GAZ/AER

Proiectare• Redundanta (mai mult de o unitate in

incinta) reduce impactul unei defectiuni.

• La necesar peste 60kW, folositi mai mult de

o aeroterma o aeroterma

• Luati in considerare usi care pot fi lasate

deschise

• Folositi intotdeauna destratificatoare

– Reduc necesarul de energie cu 20%

Page 7: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

Volumul cladirii 55 x 98 x 8.5 = 45815M3 x 0.01 kw/m3 (cand nu

stim pierderile de caldura la incalzirea cu aer cald) = 45 8kW .

6 x 70 = 420 + 2 x 29 = 478 kW

Page 8: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

Diferenta intre incalzirea directa a aerului

si cea folosind apa ca agent intermediar

Incalzire directa a aerului

• Eficienta ridicata – se evita agent intermediar

• Posibilitate de recuperare caldura (PREEVA +HR, Reznorsolar)

• Ieftin la instalare

Sisteme bazate pe Apa si Aburi

• Scump la instalare– tevi, valve, pompe, cazane, etc.– Incinta separata (cost) pentru

acestea

• Scump la functionare– Pierderi pe tevi, eficienta redusa

• Combustibilul e ars unde e necesar (in special la unitati relativ mici)

• Nu se pierde suprafata de podea

• Inertie termica foarte mica

• Mai usor de incalzit doar zonele necesare, cand e necesar (in special la unitati relativ mici – UDSA, CTU, etc)

• Daca un arzator se defecteaza, efectul asupra incintei e minimizat de continua functionare a celorlalte (in special la unitati relativ mici)

– Pierderi pe tevi, eficienta redusa– Calorifere/panouri cu apa calda

functioneaza la temperaturi mai scazute – eficienta de radiate scazuta.

– Caldura de convectie tinde catre acoperis, nu catre podea unde e necesara

– Imposibil de zonat suprafata de incalzit conform cu necesitatile incintei

– Inertie termica mare – atat la aprindere cat si la inchidere

• Probleme cu sistemul central fac intregul sistem nefunctional (se opreste caldura in suprafata deservita de acest sistem)

Page 9: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

FFactori de corectie cu altitudinea

Altitudinea 0m 610m 915m 1220m 1525m 1830m 2135m

Intrare gaz 1 0,92 0,88 0,84 0,80 0,76 0,72

RPM vent 1 1,04 1,08 1.09 1,12 1,15 1,17

Putere vent 1 1,07 1,12 1,18 1,25 1,33 1,41

Se multiplica intrarea standard cu factorul de corectie pentru

a obtine intrarea reala si necesarul de rpm si putere

Page 10: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

Furnizor Brand Putere Caracteris

tici

Arzator

Roberts

Gordon

Combat 7,7-121kw Interior Tubular

Reznor UDSA/B 8-100kw Interior –

Vert/Oriz

Placi

Reznor RPVE-

2000 WM

40-91kw Exterior

2000 WM

Roberts

Gordon

Combat

PGP/POP

47-293kw Int/Ext/

Gaz/Lichid

Cutie

Reznor RP 97-388kw Rooftop

Roberts

Gordon

DF75-

Model

3089

129-

3060kw

Exterior /

Ardere

directa

Page 11: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

1. Aeroterme de interior

CTCU si CTU

Putere intrare neta Putere intrare neta

CTCU: 7,7kw - 34,7

CTU : 25kw - 121kw

Page 12: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

Caracteristici Generale

• Eficienta 91.5%

• Disponibile pe gaz natural si propan

• Poate fi utilizata doar in interior• Poate fi utilizata doar in interior

• Permite mutarea cosurilor si a intrarii aerului de combustie din spatele unitatii, deasupra acesteia. (doar pentru CTCU)

• Control – NRG (acelasi ca la tuburi radiante BlackHeat)

Page 13: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

Optiuni Ventilator• ___A: Ventilator Axial (CTCU disponibil doar cu optiunea ventilator axial)

• ___B: Ventilator Centrifugal pentru aplicatii fara tubulatura pentru aplicatii fara tubulatura

• ___C: Ventilator Centrifugal cu adaptor pentru aplicatii cu tubulatura

• ___D: Fara ventilator

Page 14: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

Schimbator de Caldura

• Unitatile au schimbatoare tubulare de caldura si evacuare

fortata a gazelor arse.

– Unitatile CTCU au 6 treceri (sectiuni tub indoite)

– Unitatile CTU have 4-treceri (sectiuni tub indoite)

Page 15: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AERAEROTERME GAZ/AER

Diametru �

CTU 22-60 100 mm CTU 75-115 130 mm

Lungime Maxima

Oxigen ardere

din exterior

CTU 22 – 6 m

CTU 115 – 19 m

Page 16: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AERAEROTERME GAZ/AER

Diametru �

CTU 22-60 100 mm CTU

75-115 130 mm

Lungime Maxima

Oxigen ardere

din interior

CTU 22 – 6 m

CTU 115 – 19 m

Page 17: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AERAEROTERME GAZ/AER

2. Aeroterme UDSA/UDSB

Page 18: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AERAEROTERME GAZ/AER

Evolutia produselor

Reznor este cel mai mare

producator de aeroterme

gaz/aer din lume

Combinatia Calitate/Pret a dus

la leadership mondial

Page 19: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AERAEROTERME GAZ/AER

UDSA

Page 20: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AERAEROTERME GAZ/AER

V3 - UDSA

◙ 14 modele: 8 - 100 kW

◙ Unitati de interior

◙ Ardere separata

◙ Instalare verticala sau orizontala

◙ Ventialor axial

Caracteristici

◙ Spatii mici si mari

◙ Fabrici

◙ Magazine

◙ Garaje

◙ Magazii

APPLICATII

Page 21: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AERAEROTERME GAZ/AER

◙ Aeroterme de interior

◙ 9 modele: 15 – 65 kW

◙ Functionare orizontala sau verticala

◙ Ventilator centrifugal

◙ Ideal pentru tubulatura

◙ Ardere separata

Caracteristici

V3 - UDSBD

* Outlet grill is optional

◙ Spatii mici si mari

◙ Fabrici

◙ Magazine

◙ Garaje

◙ Magazii

APLICATII

Page 22: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

Optiuni

•Refulare la 30 sau •Refulare la 30 sau 60 de grade.

•Zabrele orizontale

Page 23: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

3. Destratificatoare

Maximizor – ReznorMaximizor – Reznor

ESF 14 si HVE – Roberts Gordon

Page 24: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

• Intre 2100 si 9000 m³/h

MAXIMIZOR

Ventilatoare pentru destratificare

Page 25: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

Destratificatoare Seria M (Maximizor)

N=Vx2/(VPrim x 1,5)

Exemplul anterior – V=55x98x8,5=45815

Pentru M4500 VPrim = 8840Pentru M4500 VPrim = 8840

N= 7

Page 26: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

ESF 14 si HVE

Ventilatoare pentru destratificare

Viteza redusa (zgomot redus)

Volum mare de aer

Control viteza ventilator (exterior)

Pana la 8m inaltime

Relativ ieftin

Inaltime de montare mare

Viteza mare (zgomot mai mare)

Control temperatura (intern)

Intre 6 si 25m inaltime

Ceva mai scump

• Intre 4000 si 11000 m³/h

Page 27: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

Destratificatoare ESF 14, (pana la 6m inaltime).

• Calculati volumul incintei in m3 (V).

•Multiplicati V cu 8 si impartiti la 17820 (debitul unitatii

in m3/hr) = Numar de destratificatoare

•Exemplul anterior – V=55x98x8,5=45815

•(55 x 98 x 8.5 x 8)/17820 = 20.6 Fans

Destratificatoar HVE (peste 6m inaltime)

•D (debit/hr prin destratificatoare) = (0.33 x V) x 5

•D / debitul unei unitati = Numar unitati.

Pentru HVE 400:75594/1,4/3600= 18 unitati

Pentru HVE 650:75594/3/3600= 7 unitati

Page 28: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

4. Aeroterme de exterior

RPVE2000-WM – Reznor RPVE2000-WM – Reznor

Page 29: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

RPVE 2000 WM

Putere nominala:

40, 50, 68, 91 kw

Page 30: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

RPVE 2000 WM

•Optiune pt protejarea aerului la intrare

•Cu sau fara tubulatura pentru intoarcere din

interior

Page 31: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

5. Unitati amplasate vertical

Combat - Roberts GordonCombat - Roberts Gordon

Page 32: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

Combat PGP/POP 15 = 47,4 kw si

Combat PGP/POP 100 = 293,4 kw

PGP – echipamente cu gaz natural

POP – echipamente cu combustibil lichidPOP – echipamente cu combustibil lichid

Tipuri de unitati•Interior: Verticale sau Orizontale

•Exterior•Cu debit ridicat (refulare pe tubulatura)

Page 33: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

Caracteristici generale• Eficienta 91.5%

• Doua capete de refulare

• Unitatile de 1,7m – 1,9m inaltime

• Ventilator la baza unitatii asigura intoarcerea aerului la nivelul • Ventilator la baza unitatii asigura intoarcerea aerului la nivelul podelei

• Disponibil cu:– Ventilator standard sau de putere mare.

– Gaz (NG sau LPG) si motorina (motorina usoara si gaz lampat).

– Montare in interior sau exterior.

– Aplicatii cu si fatubulatura.

• Diagnostic LED

• Control Inteligent: NRG

Page 34: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

Schimbator de Caldura

• Unitatile au tambur si schimbator de caldura cu

arzator ECOFLAM.

– Arzator disponibil in:

• Pornit/Oprit

• Inalt/Jos/Oprit

• Ajustare (Gas Only)

Page 35: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

Crestere de temperatura in

unitatea verticala

55o

5o

Delta T=50o

Page 36: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AERAEROTERME GAZ/AER

6. Aeroterme cu Ardere Directa

(DF)

Combat – Roberts GordonCombat – Roberts Gordon

Page 37: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AERAEROTERME GAZ/AER

Intre DF75 cu Putere calorica intre 129 si 222k

si Model 3089 cu putere calorica de 3060kw

Aprobare CE pentru

Seria DF75-700B

orizontal sau vertical

Produsele cu ardere directa se folosesc cand exista

exhaustari mari de aer (hote sudura, ventilatoare, etc)

Aprobare CE pentru

gamele de produse

Page 38: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AERAEROTERME GAZ/AER

• Noxe emise:– CO = 5 ppm

– NO2 = 0.5ppm

– CO2 - neglijabil

• Unitatile creaza suprepresiune aducand aer de ardere direct din exteriorde ardere direct din exterior– Presiune catre geamuri, usi impinge mirosuri

create de procese tehnologice catre periferia incintei

– Teste indica o distributie foarte egala a aerului incalzit in incinta (datorita suprapresiunii)

• Instalare simpla, pe periferia unitatii

Page 39: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AERAEROTERME GAZ/AER

Configuratii pentru Ardere Directa

• Doua configuratii cu aprobare CE :• Make-Up Air (MUA)

• 100% aer proaspat;

• Refulare constanta a volumului de aer• Refulare constanta a volumului de aer

• Air Management (AM) • Raport variabil al aerului proaspat

(AP)/recilculat (AR)de la 80% AR / 20%AP la

0%AR /100%AP;

• Refulare constanta a volumului de aer.

• Air Management cu Exhaustare (AME) – AM cu

capacitate evacuare gaze arse (doar Seria 3000)

Page 40: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AERAEROTERME GAZ/AER

7. Produse modulare

Europak RPV - ReznorEuropak RPV - Reznor

Page 41: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AERAEROTERME GAZ/AER

Europak RPV - incalzire

• Sistem modular, optiuni selectate

conform nevoilor clientului

• Combinatii de 1-4 sectiuni incalzire • Combinatii de 1-4 sectiuni incalzire

(pana la 378kw)

• Optiuni ventilatoare dau intre 8500

si 36000 m3/h

• Pana la 400 Pa presiune externa

• Unitati de Interior sau Exterior

• Motor si arzator in trepte sau

modulat

Page 42: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

8. Aeroterme electrice

Sesco

Page 43: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

Puteri intre 3,3 si 48kw

Aeroterme SESCO cu incalzire

electrica

Puteri intre 3,3 si 48kw

Folosite cand:

*accesul la gaz este limitat,

*la altitudini inalte,

*aerul de ardere este imbacsit.

Protectie la supraincalzire

Utilizabile pana la 4000m altitudine

Page 44: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AERAEROTERME GAZ/AER

Incalzire electrica pentru

tubulatura

Putere: 2kw– 50 kw

1-2 trepte, dep[inzand de puterea necesara

Elemente incalzire

1-2 trepte, dep[inzand de puterea necesara

Panou control

Protectie la supraincalzire

Panou conectare

Page 45: Aeroterme - prodimar.ro · AEROTERME GAZ/AER Ghidaj aer la 30 grade H Distanta aproximativa aruncare orizontala (m) H/Putere 30kw 45kw 60kw 75kw 120kw 2,4m 20 23 26 30 38 3m 17 20

AEROTERME GAZ/AER

SESCO produce o gama larga –

aproximativ 100 tipuri - de produse de

incalzit care folosesc electricitate

La cerere, putem discuta problemele

dumneavoastra specifice