9
LG Multi Split system is an advanced air conditioning system of superior quality that has the ability to operate at different temperatures and fan speeds in individual rooms. The multi split system can be made up of large indoor units for living areas and small indoor units for bedrooms, all operated from the one common outdoor unit. Multi Split

aer-conditionat-multisplit-lg-unitati-externe-pliant-date-tehnice.pdf

Embed Size (px)

Citation preview

  • LG Multi Split system is an advanced air conditioning system of superior quality that has the ability to operate at different temperatures and fan speeds in individual rooms. The multi split system can be made up of large indoor units for living areas and small indoor units for bedrooms, all operated from the one common outdoor unit.

    Multi Split

    1850Hz,R

    22/R410A

    Dimensions

    5CSDR-01B

    DuctedType

    6.Dimensions

    6.1Indoor

    units

    76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner

    CHASSIS CODE: BV

    Ducted Type

    AB-H1208VA0 [B120AH SV0]

    Air discharge flange

    Part Name

    Air suction flange

    Liquid pipe connectionGas pipe connection

    5

    No.

    2

    43

    1Remark

    Heating Capacity

    Net cooling capacity

    Gross cooling capacity

    Power supply

    LiquidGas

    Drain(OD/ID)

    PipingConnections

    mm(inch)

    mm

    mm(inch)15.88(5/8)

    34/2828.58(11/8)

    kW

    /V/Hz

    kWBtu/h

    Btu/h

    kWBtu/h

    112,000

    130,000

    3 / 380 - 415 / 50

    32.8

    34.3117,000

    38.1

    LG Electronics

    Note

    2. Unit shall be grounded in accordance with the local regulations or applicable national codes.

    1. Unit should be installed in compliance with the installation manual in the product box.

    2050Hz,R

    22/R410A

    Dimensions

    5CSDR-01B

    DuctedType

    6.2Outdoor

    units

    76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner

    CHASSIS CODE: UW

    LG Electronics

    OUTDOOR UNIT

    AB-H1208VA0 [B120AH SV0]

    Air suction grille

    Part Name

    Air discharge grille

    Gas pipe connection

    Power & transmission connectionLiquid pipe connection

    5

    No.

    2

    43

    1Remark

    Heating Capacity

    Net cooling Capacity

    Gross cooling Capacity

    Power supply

    LiquidGas

    PipingConnections

    mm(inch)mm(inch)

    kW

    /V/Hz

    kWBtu/h

    Btu/h

    kWBtu/h

    Technical Specification

    Note

    danielagutaText Box CALOR SRL Str. Progresului nr. 30-40, sector 5, Bucuresti tel: 021.411.44.44, fax: 021.411.36.14 www.calorserv.ro - www.calor.ro

  • Multi Split

    High Efficiency Multi

    High COP & Energy Saving

    Top Class Energy EfficiencyIn 2010, LG Inv. Multi New Model has Top class Energy Efficiency Model using LG BLDC Compressor, BLDC motor, high efficiency heat exchanger.

    1) KFRI(Korea Forest Research Institute) calculated based on annual power save. (Assumption : Using AC 4hr/day, 365days)2) Energy saving 37% was compared with LG Non-inverter model

    1

    DC Inverter TechnologyWith the advancement of inverter technology comes more silent, economical and powerful air conditioning systems.The LG air conditioner is manufactured using the PFC and the sine wave technology.

    Step-up Inverter by the PFC & the Sine Wave Control Technology (PFC : Power Factor Correction)compared to conventional.

    Loss Full range

    DC280V

    VI

    Partial switching

    VI

    Full range Sine wave switching

    DC 380V(Boost up)

    Sine wave Control in BLDC Compressor

    Sine waveRectangle wave

    Loss Full range

    DC280V

    VI

    Partial switching

    VI

    Full range Sine wave switching

    DC 380V(Boost up)

    PFC Control in Power Input

    BLDC Fan Technology BLDC Fan motor offers additional energy saving in operating mode. Compared with AC motors, BLDC Fan motor can cut energy by 35% at full velocity.

    0200

    Motor Speed(rpm)

    DC motor

    AC motorApprox40%

    increase

    Eff

    icie

    ncy(

    %)

    300 400 500 600 700 800 900 1000

    20

    40

    60

    80

    100

    Approx20%

    increase

    Minimized Oil circulation

    High Efficiency Motor

    Optimize Compression Eff.

    1

    2

    Optimize Vibration, Noise

    High Reliability

    4

    5

    3

    1

    2

    4

    5

    3

    Powerful BLDC CompressorThe LG inverter air conditioner comes with a BLDC compressor that uses a strong neodymium magnet. Its compressor thus has improved efficiency compared with AC inverter.

    BLDC Fan motor

    Energy Efficiency

    More Heat exchanger

    Height : 6%

    Length : 8%

    Wide Louver techHeat exchange rate(%)

    Corrugate fin Wide louver fin

    (%)

    -15 1 7 35

    (COP)

    100

    123128

    0

    +5%+8% +7%

    +2%

    100% 100%

    128%123%

    CoolingC

    C

    H

    H C H

    Condensing

    Evaporation

    Condensing

    Evaporation

    Heating Improved heat exchange rate by max 28%

    Anti-corrosion treatment (Gold fin)

    3 Step Axial fan shape can be available of high-effident & low noise

    Static Pressure

    Before After

    Axial Fan

    1

    2

    3

    Leading edge

    Trailing edge

    Prevent Oil Discharge at High Hz !

    Adopt Oil Separate & Optimize Oil Path

    For keeping Oil level in high Hz , Improved Oil circulation system So. LG inv. Multi can have high reliability system

    Using LG Inverter AC is same

    as planting 138 big cone pines.

    Using LG Inverter AC 138 big cone pines

    =

    EnergySaving37%

    MU3M19

    4.4

    4.8

    4.0

    4.3

    4.0

    4.6 4.64.1

    3.8

    4.6

    MU3M21 MU4M25 MU4M27 MU5M30

    Cooling

    COP

    Heating

    LGH-Inverter

    3.72

    4.46

    3.704.16

    3.61

    4.12

    A Company B Company

    CoolingHeating

    Using LG Inverter AC is same as planting 138 big cone pines.

  • Multi Split

    According to construction regulation, house wall is becoming thicker & to strenghten insulation, LG can provide right solution to small space.

    Wide Operating RangeWhen cooling computer rooms and other rooms in the event of low outdoor temperature, the BLDC inverter compressor and outdoor BLDC fan motor are used to adjust the air flow and volume, with a view to ensuring efficient operation by allowing the air conditioner to keep operating at -10C without turning it off.

    The Variety of Various Combination

    Comfort Application2 Available from 1.5kW

    www.lgeaircon.com

    1.5 kW

    1.5 kW

    Don't you worry about consumption for using

    Big capacity in Small space?

    LG Air Conditioner

    LG Recomend the 1.5kWAir Conditioner for the First

    www.lgeaircon.com

    1.5 kW

    1.5 kW

    Don't you worry about consumption for using

    Big capacity in Small space?

    LG Air Conditioner

    LG Recomend the 1.5kWAir Conditioner for the First

    www.lgeaircon.com

    1.5 kW

    1.5 kW

    Don't you worry about consumption for using

    Big capacity in Small space?

    LG Air Conditioner

    LG Recomend the 1.5kWAir Conditioner for the First

    Wall Mounted

    LiBERO

    Artcool Mirror

    Console

    Artcool Gallery & Panel

    Convertible

    Hero

    Low static ductHigh static duct

    Ceiling Cassette 4-Way

    Ceiling Cassette 1-Way

    15 Outdoor Units46 Indoor Units

    More than2000 types Indoor Capacity Combination

    8.8kW

    2.6kW

    2.6kW

    3.5kW

    3.5kW160%

    Max Combination

    7.0kW

    2.6kW

    2.6kW

    2.6kW

    3.5kW163%

    Max Combination2.6kW

    2.6kW

    3.5kW5.3kW

    167%Max Combination

    * Common usage of Multi & SRAC Indoor unit

    Libero : 9K~24K BTU

    Hero : 9K~12K BTU

    ART COOL : 9K~24K BTU

    For Reference Sites

    OfficeRestaurant BuildingHouse

    Ind

    oo

    r Te

    mp

    (C)

    Outdoor Temp(C)

    10

    18

    30

    32

    -15

    21

    -10 21 35 43

    Cooling

    Heating

    Low AmbientControl

  • Comfort Operation & Ez installation3

    Multi Split

    Improved Low NoiseThe Inverter technology, the BLDC Motor technology, and LGs unique new Skew Fan technology have achieved the worlds lowest noise level of 19dB. Thus, the Sleep mode will allow pleasant sleeping.

    Noise Level

    Outdoor 45dB

    Indoor 19dB

    LG Air Conditioner

    19dB

    Woods26dB

    Library33dB

    Conventional Inv.

    Conventional On / Off

    22dB

    32dB

    *Only LIBERO_9k,12k

    Long & High Elevation Piping

    Max 145m pipe run / 30m Elevation

    The FM56AH supports a piping length of up to 145m and high elevation of up to 30m for more flexibility in installation

    Remove outdoor unit From Balcony and Move to car parking lot or Roof.

    Beauty care centerEasy to get approval from councilAvoid safety issue (Baby fall down from balcony)

    50m

    Outdoor unit

    DistributorA

    L1

    L2L3

    Indoor unit

    Outdoor unit

    Indoor unit

    15m

    30m

    *Multi Piping Type

    Total

    Max / Room

    Allowable Elevation

    (Indoor-Outdoor)

    (Indoor-Indoor

    3020

    157.5

    5025

    157.5

    7025

    157.5

    7525

    157.5

    8525

    157.5

    Piping Length(m)

    15/17k

    19k/21k

    25k/27k

    30k 40k

    Total Pipe (A+L1+L2+L3)Main Pipe(A)Total Branch Pipe (L1+L2+L3)Each Branch PipeAllowable Elevation

    Indoor-Outdoor (B)Indoor-Indoor (C)

    100505015

    3015

    135558015

    3015

    145559015

    3015

    Piping Length(m) 40k 48k 56k

    *Distributor Box Type

    LG MV Easy start-up, easy trouble shooting

    Monitoring the normality of all parts such as compressor, fan, valve, etc

    *LG does not supply home network. Only available to link.

    Available to link with home network

    Command

    Sensor reading

    Easy & efficient installation of outdoor unit will provide the best solution for small offices and shops.

    Easy to Service

    3 pieces of screw

    Ez SVC

    1. Inner SVC valve- 4 Way piping is possible (Front, Rear, Right, Down)- Excellent exterior

    4 way1 way

    2. Convenient moving handle- Fitted hand grips for easy transportation and installation

    3. Compact Design & Ez SVC- Remove 3 pieces of screw for SVC- Front panel removal system

    Smart phone Solution for Operation monitoring & Trouble shootingSmart phone connectionWhen faults have occurred, you can see the Error code during the check of indoor and outdoor units, select the Error code, and find solutions to each problem through Q&A. It is like the trouble shooting guide book embedded in the smart phone.

    Wired Bluetooth Module

    LG MV software on Smart phone

    RS-232Operation Monitoring

    Select communication method and language

    Check the installation status

    Compressor operation status

    Check the indoor unit status

    Operational status in line with the frequency

    Troubleshooting on Smart phone

    1. Select Error Code

    2. Easy Process

    3. Service Action

    Air Conditioner

    Home Server

    Internet

    Digital Door Lock Emergency Switch Motion Detect Sensor

    Living Room Light Kitchen TV Door Phone

    Remote Switch

    Air Conditioner

    Home Server

    Internet

    Digital Door Lock Emergency Switch

    Living Room Light Kitchen TV Door Phone

    Remote Switch

    For Less 10 Floors

  • Multi SplitWide RangeLG Multi systems provide various indoor units and outdoor units up to 16.4kW. More than 2,000 types of combinations are available using 15 outdoor units and 48 indoor units

    Free Combination with Various Indoor Types

    Product

    Tyte

    Capacity Range

    (kBtu/kW)

    Category

    7/2.1

    Model

    5/1.5

    9/2.6

    CapacityKW(C/H)

    Max.Indoor units

    12/3.5

    18/5.3

    Phase

    24/7.0

    Ceiling Concealed Duct Type

    Slim Duct High

    Ceiling & Floor TypeConsole

    Ceiling Cassette Type

    1-wayGallery

    4-way

    Wall Mounted Type

    Multi Piping DB Box Type

    Mirror Panel

    MS05AH N40

    MS07AH N40

    MS09AH N40

    MS12AH N40

    MS18AH N50

    MS24AH N50

    MU2M15 UL0MU2M17 UL0

    4.1/4.74.7/5.3

    22

    MU4M27 U40MU5M30 U40

    7.9/9.18.8/10.1

    45

    FM48AH U33FM56AH U33

    15.5/16.416.7/17.9

    89

    MU3M19 UE0MU3M21 UE0MU4M25 UE0

    FM41AH U33FM49AH U33FM57AH U33

    MU5M40 UH0 FM40AH UH5 FM37AH UE0

    1 1 1 1 1 1 3 3

    5.3/6.36.2/7.07.0/8.4

    13.5/14.115.5/16.416.7/17.9

    11.7/13.5 11.7/13.5 9.7/11.1

    334

    789

    5 7 6

    CS05AF NH0

    CS07AF NH0

    CS09AF NH0

    CS12AF NH0

    MT06AH NR0

    MT08AH NR0

    MT10AH NR0

    MT12AH NR0

    MT18AH NQ0

    MT24AH NP0

    CS07AQ NB0

    CS09AQ NB0

    CS12AQ NB0

    CS18AQ NC0

    CS24AQ NC0

    CC07AW* NE3

    CC09AW* NE3

    CC12AW* NE3

    CC18AW* N83

    CC24AW* N83

    MA09AH1 NF1

    MA12AH1 NF1

    MA09AH* NF1

    MA12AH* NF1

    CQ09 NA0

    CQ12 NA0

    CQ18 NA0

    MT09AH NC1

    MT11AH NC1

    MB09AHL N12

    MB12AHL N12

    MB18AHL N22

    MB24AHL N22

    MB18AH NH0

    MB24AH NH0

    MV09AH NE0

    MV12AH NE0

    MV18AH NB0

    MV24AH NB0

    Wall Mounted

    Note : * indicates color of panel

    *Blue(B) *Mirror(R) *Silver(V) *Red(E) *Gold(G) *White Silver(H) *Gallery(1)

  • Specifications_Outdoor UnitsSpecifications_Outdoor Units

    MU2M15 UL0 MU2M17 UL0

    Notes: 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27C (80.6F) DB /19C (66.2F) WB - Outdoor Temperature 35C (95F) DB /24C (75.2F) WB Heating: - Indoor Temperature 20C (68F) DB / 15C(59F) WB - Outdoor Temperature 7C (44.6F) DB / 6C (42.8F) WB Piping Length - Interconnecting Piping Length 7.5m - Level Difference of Zero. 2. * : See page "Combination Table". 3. Due to our policy of innovation some specifications may be changed without notification. 4. At least two indoor units should be connected.5. Minimum combination capacity rate should be more than 40%.

    Notes: 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27C (80.6F) DB /19C (66.2F) WB - Outdoor Temperature 35C (95F) DB /24C (75.2F) WB Heating: - Indoor Temperature 20C (68F) DB / 15C(59F) WB - Outdoor Temperature 7C (44.6F) DB / 6C (42.8F) WB Piping Length - Interconnecting Piping Length 7.5m - Level Difference of Zero. 2. * : See page "Combination Table". 3. Due to our policy of innovation some specifications may be changed without notification. 4. At least two indoor units should be connected.5. Minimum combination capacity rate should be more than 40%.

    Model Nominal Capacity* Cooling Btu/h (Min~Rated~Max) kW Heating Btu/h kW Nominal Input* Cooling kW (Min~Rated~Max) Heating kW Energy label Testing Combination

    Running Current Cooling A (Min~Rated~Max) Heating A Power Supply / V / Hz Dimensions W*H*D mm(inch) Net Weight kg(lbs) Max. Number of Connectable Indoor Units Refrigerant Charge (at 7.5m) g(oz) Air Flow Rate CMM(CFM) Sound Level Sound Pressure at 1m dB(A)+3 Piping connections Liquid() mm(inch) Gas() mm(inch) Max. Interunit Total of Each Room m Piping Length For One Room m Max. Elevation Indoor Unit~Outdoor Unit m Indoor Unit~Indoor Unit m

    MU2M15 UL0

    4,600~14,000~16,0001.35~4.10~4.69

    4,800~16,000~18,0001.41~4.70~5.27 0.38~1.07~1.70 0.45~1.12~1.80

    A/A

    CS07AQ NB0 2EA

    1.6~4.9~7.6 1.7~5.1~8.2

    1 / 220~240 / 50 770545288 (30.321.511.3)

    35(77.2) 2

    1100(38.8) 28.2(995)

    50 6.35(1/4)2EA 9.52(3/8)2EA

    3020157.5

    MU2M17 UL0

    4,600~16,000~17,500 1.35~4.69~5.13

    4,800~18,000~19,500 1.41~5.27~5.71 0.4~1.38~1.83 0.39~1.31~1.73

    A/A

    CS09AQ NB0 2EA

    1.6~6.13~8.041.7~5.88~7.51

    1 / 220~240 / 50 770545288 (30.321.311.3 )

    40(88.2) 2

    1300(42.3) 28.2(995)

    50 6.35(1/4)2EA 9.52(3/8)2EA

    3020157.5

    Model Nominal Capacity* Cooling Btu/h (Min~Rated~Max) kW Heating Btu/h kW Nominal Input* Cooling kW (Min~Rated~Max) Heating kW Energy label Testing Combination

    Running Current Cooling A (Min~Rated~Max) Heating A Power Supply / V / Hz Dimensions W*H*D mm(inch) Net Weight kg(lbs) Max. Number of Connectable Indoor Units Refrigerant Charge (at 7.5m) g(oz) Air Flow Rate CMM(CFM) Sound Level Sound Pressure at 1m dB(A)+3 Piping connections Liquid() mm(inch) Gas() mm(inch) Max. Interunit Total of Each Room m Piping Length For One Room m Max. Elevation Indoor Unit~Outdoor Unit m Indoor Unit~Indoor Unit m

    MU3M19 UE0 MU3M21 UE0 MU4M25 UE0

    4,600~18,000~21,600 1.35~5.3~6.33

    4,800~21,600~24,8001.41~6.3~7.27

    0.38~1.20~2.37 0.45~1.31~2.48

    A/A

    CS07AQ NB0 3EA

    1.7~5.23~10.3 2.0~5.7~10.8

    1 / 220~240 / 50 870808320 (34.331.812.6)

    58(128)3

    2100(74.1)53(1872)

    52 6.35(1/4)3EA 9.52(3/8)3EA

    5025157.5

    6,300~21,000~25,0001.85~6.15~7.33

    7,560~24,000~26,5002.22~7.03~7.77 0.72~1.53~2.94 0.88~1.63~2.95

    A/A

    CS07AQ NB0 3EA

    3.1~6.65~12.7 3.8-7.1-12.8

    1 / 220~240 / 50 870808320 (34.331.812.6)

    61(134)3

    2300(81.13)53(1872)

    526.35(1/4)3EA9.52(3/8)3EA

    5025157.5

    6,300~24,000~29,0001.85~7.03~8.5

    7,560~28,000~32,000 2.22~8.44~9.38 0.72~1.75~3.09 0.88~1.83~3.10

    A/A

    CS07AQ NB0 4EA

    3.1~7.65~13.4 3.8~8.0~13.5

    1 / 220~240 / 50 870808320 (34.331.812.6)

    61(134)4

    2300(81.13)53(1872)

    52 6.35(1/4)4EA 9.52(3/8)4EA

    7025157.5

    MU3M19 UE0 MU3M21 UE0 MU4M25 UE0

    40 Dimensional drawings

    5RMI0-03A

    Inverter Single

    CHASSIS CODE : UL2

    [Unit : mm] [Unit : mm]

    148Outdoor unit - DC Inverter SINGLE A (1, 3)

    5CSL0-05ADim

    ensions

    1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.

    Note

    AUUW246D[UU24W UED]AUUW306D[UU30W UED]

    Model namePower Supply

    Cooling CapacityHeating CapacityPiping

    ConnectionsLiquidGas

    /V/HzkWkWmm

    mm

    AUUW246D[UU24W UED]1/ 220~240 / 50

    9.5215.88

    AUUW306D[UU30W UED]1/ 220~240 / 50

    9.5215.88

    Simultaneous operationRefer to combination table

    OUTDOOR UNIT

    No.123456

    krameRemaN traPAir discharge grilleGas pipe connectionLiquid pipe connectionPower & transmission connectionEarth screwSVC valve cover

    (Unit:mm) (Unit:mm)

    Multi Split _

  • Outdoor unit - DC Inverter SINGLE A (1, 3)153

    5CSL0-05ADim

    ensions

    76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner

    CHASSIS CODE: U4

    OUTDOOR UNIT

    AUUW216DH [UU21WH U4D]AUUW246DH [UU24WH U4D]

    Gas pipe connection

    Part Name

    Air discharge grille

    Liquid pipe connection

    Earth screwPower & transmission connection

    5

    Item No.

    2

    43

    1Remark

    Technical Specification

    1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.

    Note

    AUUW216DH [UU21WH U4D]1/ 220~240 / 50

    9.5215.88

    AUUW246DH [UU24WH U4D]1/ 220~240 / 50

    9.5215.88

    Model namePower Supply

    Cooling CapacityHeating CapacityPiping

    ConnectionsLiquidGas

    /V/HzkWkWmm

    mm

    Simultaneous operationRefer to combination table

    Specifications_Outdoor UnitsSpecifications_Outdoor Units

    Notes: 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27C (80.6F) DB /19C (66.2F) WB - Outdoor Temperature 35C (95F) DB /24C (75.2F) WB Heating: - Indoor Temperature 20C (68F) DB / 15C(59F) WB - Outdoor Temperature 7C (44.6F) DB / 6C (42.8F) WB Piping Length - Interconnecting Piping Length 7.5m - Level Difference of Zero. 2. * : See page "Combination Table". 3. Due to our policy of innovation some specifications may be changed without notification. 4. At least two indoor units should be connected.5. Minimum combination capacity rate should be more than 40%.

    MU4M27 U40 MU5M30 U40

    MU5M40 UH0

    Notes: 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27C (80.6F) DB /19C (66.2F) WB - Outdoor Temperature 35C (95F) DB /24C (75.2F) WB Heating: - Indoor Temperature 20C (68F) DB / 15C(59F) WB - Outdoor Temperature 7C (44.6F) DB / 6C (42.8F) WB Piping Length - Interconnecting Piping Length 7.5m - Level Difference of Zero. 2. * : See page "Combination Table". 3. Due to our policy of innovation some specifications may be changed without notification. 4. At least two indoor units should be connected.5. Minimum combination capacity rate should be more than 40%.

    169

    Product data

    Outdoor units_Multi piping type

    Part 2 Product data

    76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner

    CHASSIS CODE: UH

    OUTDOOR UNIT

    A5UW406FA3 [FM38AH UH3]

    Gas pipe connection

    Part Name

    Air discharge grille

    Liquid pipe connection

    Earth screwPower & transmission connection

    5

    No.

    2

    43

    1Remark

    Heating Capacity

    Cooling Capacity

    Power supply

    Liquid()Gas()

    PipingConnections

    mm(inch)mm(inch)

    6.35(1/4)9.52(3/8)

    kW/V/Hz

    kWBtu/h

    Btu/h

    1 / 220-240 / 50

    11.740,00013.5

    46,000

    Technical Specification

    Note

    5

    1135

    1165

    308

    565

    273

    520

    900550

    370

    395

    15

    175

    4

    370

    7

    6

    1

    Main service valve(Liquid)Main service valve(Gas)

    6

    7

    50*4

    =200

    148

    50

    50

    3

    2

    1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.5. When pumping down the system, use main service valve. When you are installing the system, not used valve should be closed by cap that equipped from factory.

    [Unit : mm]

    1135

    1165

    308

    565

    273

    520

    900550

    370

    395

    15

    175

    370

    50*4

    =200

    148

    50

    50

    [Unit : mm]

    Model Nominal Capacity* Cooling Btu/h (Min~Rated~Max) kW Heating Btu/h kW Nominal Input* Cooling kW (Min~Rated~Max) Heating kW Energy label Testing Combination

    Running Current Cooling A (Min~Rated~Max) Heating A Power Supply / V / Hz Dimensions W*H*D mm(inch) Net Weight kg(lbs) Max. Number of Connectable Indoor Units Refrigerant Charge (at 7.5m) g(oz) Air Flow Rate CMM(CFM) Sound Level Sound Pressure at 1m dB(A)+3 Piping connections Liquid() mm(inch) Gas() mm(inch) Max. Interunit Total of Each Room m Piping Length For One Room m Max. Elevation Indoor Unit~Outdoor Unit m Indoor Unit~Indoor Unit m

    MU4M27 U40

    6,300~27,000~32,4001.85~7.91~9.49

    7,560~31,000~36,0002.22~9.08~10.550.72~1.98~3.120.88~1.97~3.68

    A/A

    CS07AQ NB0 4EA

    3.1~8.6~13.53.8~9.0~16.01/220~240/50

    950834330(37.432.813.0)67(147.7)

    43,300(116.4)

    60(2119)53

    6.35(1/4)4EA9.52(3/8)4EA

    7025157.5

    MU5M30 U40

    6,300~30,000~36,0001.85~8.80~10.55

    7,560~34,500~41,4002.22~10.1~12.10.72~2.31~3.160.88~2.19~3.87

    A/A

    CS07AQ NB0 5EA

    3.1~10.1~13.73.8~9.6~16.81/220~240/50

    950834330(37.432.813.0)67(147.7)

    53,300(116.4)

    60(2119)53

    6.35(1/4)5EA9.52(3/8)5EA

    7525157.5

    Model Nominal Capacity* Cooling Btu/h (Min~Rated~Max) kW Heating Btu/h kW Nominal Input* Cooling kW (Min~Rated~Max) Heating kW Energy label Testing Combination

    Running Current Cooling A (Min~Rated~Max) Heating A Power Supply / V / Hz Dimensions W*H*D mm(inch) Net Weight kg(lbs) Max. Number of Connectable Indoor Units Refrigerant Charge (at 7.5m) g(oz) Air Flow Rate CMM(CFM) Sound Level Sound Pressure at 1m dB(A)+3 Piping connections Liquid() mm(inch) Gas() mm(inch) Max. Interunit Total of Each Room m Piping Length For One Room m Max. Elevation Indoor Unit~Outdoor Unit m Indoor Unit~Indoor Unit m

    MU5M40 UH0

    9,600~40,000~46,0002.8~11.7~13.5

    11,040~46,000~51,0003.2~13.5~15.01.1~3.63~4.651.4~3.65~4.84

    A/A

    MS09AH N40 5EA

    6.2~16.0~20.06.9~16.4~20.51/220~240/50

    9001165370(35.445.814.5)95(209)

    54,000(141.1)53(1872)2

    586.35(1/4)5EA9.52(3/8)5EA

    8525157.5

    (Unit:mm) (Unit:mm)

    Multi Split _

  • Specifications_Outdoor UnitsSpecifications_Outdoor Units

    FM40AH UH5

    Notes: 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27C(80.6F) DB /19 C(66.2F) WB - Outdoor Temperature 35C(95F) DB /24C(75.2F) WB Heating: - Indoor Temperature 20C(68F) DB / 15C(59F) WB - Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB Piping Length - Main piping 5m, Branch piping 5m - Level Difference of Zero. 2. * : See page "Combination Table" 3. Due to our policy of innovation some specifications may be changed without notification. 4. At least two indoor units should be connected.5. Minimum combination capacity rate should be more than 40%.

    Model11,400~52,800~58,000

    3.3~15.5~17.012,768~56,000~59,000

    3.7~16.4~17.290.84~4.69~5.351.30~4.43~5.58

    A/AMS07AH N40 5EAMS09AH N40 3EA

    3.9~21.1~23.26.9~22.6~25.01/220~240/50

    9501380330 (37.454.313.0)108(238)

    84800(169.3)

    60(2,119) 258

    9.52(3/8)19.05(3/4)

    135

    5580153015

    13,800~57,000~63,2004.0~16.7~18.52

    15,456~61,000~64,0004.5~17.9~18.751.0~4.96~5.65

    1.25~4.62~5.70A/A

    MS09AH N408EA

    4.6~21.7~24.07.4~22.4~26.01/220~240/50

    9501380330 (37.454.313.0)108(238)

    94800(169.3)

    60(2,119) 259

    9.52(3/8)19.05(3/4)

    145

    5590153015

    Nominal Capacity* Cooling Btu/h (Min~Rated~Max) kW Heating Btu/h kW Nominal Input* Cooling kW (Min~Rated~Max) Heating kW Energy label Testing Combination

    Running Current Cooling A (Min~Rated~Max) Heating A Power Supply / V / Hz Dimensions W*H*D mm(inch) Net Weight kg(lbs) Max. Number of Connectable Indoor Units Refrigerant Charge (at 7.5m) g(oz) Air Flow Rate CMM(CFM) Sound Level Sound Pressure at 1m dB(A)+3 Piping connections Liquid() mm(inch) Gas() mm(inch) Max. Interunit Total Piping m Piping Length (Main+Total Branch) Main Piping m Total Branch Piping m Each Branch Piping m Max. Elevation Indoor Unit~Outdoor Unit m Indoor Unit~Indoor Unit m

    Notes: 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27C(80.6F) DB /19 C(66.2F) WB - Outdoor Temperature 35C(95F) DB /24C(75.2F) WB Heating: - Indoor Temperature 20C(68F) DB / 15C(59F) WB - Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB Piping Length - Main piping 5m, Branch piping 5m - Level Difference of Zero. 2. * : See page "Combination Table" 3. Due to our policy of innovation some specifications may be changed without notification. 4. At least two indoor units should be connected.5. Minimum combination capacity rate should be more than 40%.

    FM48AH U33 FM56AH U33

    335

    Product data

    Outdoor units_Distributor type(1)

    Part 2 Product data

    2.2.5 Dimensions

    76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner

    CHASSIS CODE: UH

    OUTDOOR UNIT

    A7UW406FA3[FM40AH UH3]

    Gas pipe connection

    Part Name

    Air discharge grille

    Liquid pipe connection

    Earth screwPower & transmission connection

    5

    No.

    2

    43

    1Remark

    Heating Capacity

    Cooling Capacity

    Power supply

    Liquid()Gas()

    PipingConnections

    mm(inch)mm(inch)

    9.52(3/8)19.05(3/4)

    kW/V/Hz

    kWBtu/h

    Btu/h

    40,000

    46,000

    1 / 220-240 / 50

    11.7

    13.5

    Technical Specification

    5

    1135

    1165

    308

    565

    273

    520

    8012

    4

    900550

    370

    395

    15

    175

    3

    2

    65

    4

    370

    Note1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.

    1

    1) Outdoor units

    [Unit : mm]

    1135

    1165

    308

    565

    273

    520

    8012

    4

    900550

    370

    395

    15

    175

    65

    370

    [Unit : mm]

    336

    Product dataOutdoor units_Distributor type(1)

    Part 2 Product data

    1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.

    76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner

    CHASSIS CODE: U3

    OUTDOOR UNIT

    A8UW486FA3[FM48AH U33]A9UW566FA3[FM56AH U33]

    Part Name

    Air discharge grilleGas pipe connectionLiquid pipe connection

    No.

    2

    3

    1Remark

    Technical Specification

    Note

    Supporter

    Heating Capacity

    Cooling Capacity

    Power supplyModel Name

    Liquid()Gas()

    PipingConnections

    mm(inch)mm(inch)

    kW

    kWBtu/h

    Btu/h

    /V/HzA8UW486FA3[FM48AH U33] A9UW566FA3[FM56AH U33]

    1 / 220-240 / 5015.5

    52,80016.4

    56,0009.52(3/8)

    19.05(3/4)

    1 / 220-240 / 5016.7

    57,00017.9

    61,0009.52(3/8)

    19.05(3/4)

    [Unit : mm] [Unit : mm]

    Model9,600~40,000~46,000

    2.8~11.7~13.511,040~46,000~51,000

    3.2~13.5~15.01.1~3.63~4.651.4~3.65~4.84

    A/A

    CS09AH NB0 7EA

    6.2~16.0~20.06.9~16.4~20.51/220~240/50

    9001165370(35.445.814.5)95(209)

    74,400(155)

    53(1872) 258

    9.52(3/8)19.05(3/4)

    100

    5050153015

    Nominal Capacity* Cooling Btu/h (Min~Rated~Max) kW Heating Btu/h kW Nominal Input* Cooling kW (Min~Rated~Max) Heating kW Energy label Testing Combination

    Running Current Cooling A (Min~Rated~Max) Heating A Power Supply / V / Hz Dimensions W*H*D mm(inch) Net Weight kg(lbs) Max. Number of Connectable Indoor Units Refrigerant Charge (at 7.5m) g(oz) Air Flow Rate CMM(CFM) Sound Level Sound Pressure at 1m dB(A)+3 Piping connections Liquid() mm(inch) Gas() mm(inch) Max. Interunit Total Piping m Piping Length (Main+Total Branch) Main Piping m Total Branch Piping m Each Branch Piping m Max. Elevation Indoor Unit~Outdoor Unit m Indoor Unit~Indoor Unit m

    FM40AH UH5 FM48AH U33 FM56AH U33

    (Unit:mm) (Unit:mm)

    Multi Split _

  • Specifications_Outdoor UnitsSpecifications_Outdoor Units

    Notes: 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27C(80.6F) DB /19 C(66.2F) WB - Outdoor Temperature 35C(95F) DB /24C(75.2F) WB Heating: - Indoor Temperature 20C(68F) DB / 15C(59F) WB - Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB Piping Length - Main piping 5m, Branch piping 5m - Level Difference of Zero. 2. * : See page "Combination Table" 3. Due to our policy of innovation some specifications may be changed without notification. 4. At least two indoor units should be connected.5. Minimum combination capacity rate should be more than 40%.

    FM37AH UE0 FM41AH U33 FM49AH U33 FM57AH U33

    Notes: 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27C(80.6F) DB /19 C(66.2F) WB - Outdoor Temperature 35C(95F) DB /24C(75.2F) WB Heating: - Indoor Temperature 20C(68F) DB / 15C(59F) WB - Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB Piping Length - Main piping 5m, Branch piping 5m - Level Difference of Zero. 2. * : See page "Combination Table" 3. Due to our policy of innovation some specifications may be changed without notification. 4. At least two indoor units should be connected.5. Minimum combination capacity rate should be more than 40%.

    381

    Product data

    Outdoor units_Distributor type(3)

    Part 2 Product data

    2.3.5 Dimensions

    1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.

    76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner

    CHASSIS CODE: U3

    OUTDOOR UNIT

    A7UW428FA3[FM41AH U33]A8UW488FA3[FM49AH U33]A9UW548FA3[FM57AH U33]

    Technical Specification

    Note

    Part Name

    Air discharge grilleGas pipe connectionLiquid pipe connection

    No.

    2

    3

    1Remark

    Supporter

    Heating Capacity

    Cooling Capacity

    Power supply

    Model Name

    Liquid()Gas()

    PipingConnections

    mm(inch)mm(inch)

    kW

    kWBtu/h

    Btu/h

    /V/Hz

    A7UW428FA3[FM41AH U33]

    A8UW488FA3[FM49AH U33]

    A9UW568FA3[FM57AH U33]

    3 / 380-415 / 5013.5

    46,00014.1

    48,0009.52(3/8)

    19.05(3/4)

    3 / 380-415 / 5015.7

    52,80016.4

    56,0009.52(3/8)

    19.05(3/4)

    3 / 380-415 / 5016.7

    57,00017.87

    61,0009.52(3/8)

    19.05(3/4)

    1) Outdoor units

    [Unit : mm] [Unit : mm]

    Model21,600~33,000~37,000

    6.33~9.67~10.822,800~38,000~42,000

    6.68~11.1~12.31.80~3.00~3.451.83~3.05~3.51

    A/A

    MS07AH N40 6EA

    3.4-5.4-6.03.5-5.4-6.1

    3 / 380~415 / 508701,038320 (34.340.912.6)

    80(176)6

    2,800(98.8)32(1,130) 2

    51/476.35(1/4)15.88(5/8)

    100

    4060203015

    Nominal Capacity* Cooling Btu/h (Min~Rated~Max) kW Heating Btu/h kW Nominal Input* Cooling kW (Min~Rated~Max) Heating kW Energy label Testing Combination

    Running Current Cooling A (Min~Rated~Max) Heating A Power Supply / V / Hz Dimensions W*H*D mm(inch) Net Weight kg(lbs) Max. Number of Connectable Indoor Units Refrigerant Charge (at 7.5m) g(oz) Air Flow Rate CMM(CFM) Sound Level Sound Pressure at 1m dB(A)+3 Piping connections Liquid() mm(inch) Gas() mm(inch) Max. Interunit Total Piping m Piping Length (Main+Total Branch) Main Piping m Total Branch Piping m Each Branch Piping m Max. Elevation Indoor Unit~Outdoor Unit m Indoor Unit~Indoor Unit m

    FM37AH UE0 Model9,600~46,000~48,000

    2.8~13.5~14.110,752~48,000~52,000

    3.2~14.1~15.20.8~4.0~4.90.89~3.9~5.1

    A/A

    MS07AH N40 7EA

    1.5~7.2~8.11.7~7.5~8.0

    3/380~415/509501380330 (37.454.313.0)

    108(238.0)7

    4,800(169.3)60(2,119) 2

    589.52(3/8)19.05(3/4)

    125

    5570153015

    11,400~52,800~58,0003.3~15.5~17.0

    12,768~56,000~59,0003.7~16.4~17.290.94~4.6~5.41.13~4.45~5.2

    A/AMS07AH N40 5EA +MS09AH N40 3EA

    1.8~8.0~8.42.1~7.5~8.3

    3/380~415/509501,380330 (37.454.313.0)

    108(238.0)8

    4,800(169.3)60(2,119) 2

    589.52(3/8)19.05(3/4)

    135

    5580153015

    13,800~57,000~63,2004.0~16.7~18.52

    15,456~61,000~64,0004.5~17.87~18.75

    1.0~4.91~5.71.49~4.55~5.65

    A/A

    MS09AH N408EA

    2.3~8.1~9.12.5~8.0~8.7

    3/380~415/509501,380330 (37.454.313.0)

    108(238.0)9

    4,800(169.3)60(2,119) 2

    599.52(3/8)

    19.05(3/4)

    145

    5590153015

    Nominal Capacity* Cooling Btu/h (Min~Rated~Max) kW Heating Btu/h kW Nominal Input* Cooling kW (Min~Rated~Max) Heating kW Energy label Testing Combination

    Running Current Cooling A (Min~Rated~Max) Heating A Power Supply / V / Hz Dimensions W*H*D mm(inch) Net Weight kg(lbs) Max. Number of Connectable Indoor Units Refrigerant Charge (at 7.5m) g(oz) Air Flow Rate CMM(CFM) Sound Level Sound Pressure at 1m dB(A)+3 Piping connections Liquid() mm(inch) Gas() mm(inch) Max. Interunit Total Piping m Piping Length (Main+Total Branch) Main Piping m Total Branch Piping m Each Branch Piping m Max. Elevation Indoor Unit~Outdoor Unit m Indoor Unit~Indoor Unit m

    FM41AH U33 FM49AH U33 FM57AH U33

    Outdoor unit - DC Inverter SINGLE A (1, 3)149

    5CSL0-05ADim

    ensions

    1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.

    Note

    AUUW366D[UU36W UED]AUUW368D[UU37W UED]

    AUUW366D[UU36W UED]1/ 220~240 / 50

    _

    9.5215.88

    Model namePower Supply

    Cooling CapacityHeating CapacityPiping

    ConnectionsLiquidGas

    /V/HzkWkWmm

    mm

    AUUW368D[UU37W UED]3/ 380~415 / 50

    9.5215.88

    Simultaneous operationRefer to combination table

    OUTDOOR UNIT

    No.123456

    krameRemaN traPAir discharge grilleGas pipe connectionLiquid pipe connectionPower & transmission connectionEarth screwSVC valve cover

    (Unit:mm) (Unit:mm)

    Multi Split _