54
Acoustic Verification System (AVS) CMU and Rohde & Schwarz CMW 500 Hardware User Manual Spirent Communications 5280 Corporate Drive, Frederick, MD. 21703 Document Version: 3.0

Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

  • Upload
    buimien

  • View
    221

  • Download
    5

Embed Size (px)

Citation preview

Page 1: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Acoustic Verification System (AVS) CMU and Rohde & Schwarz CMW 500 Hardware User Manual

Spirent Communications 5280 Corporate Drive, Frederick, MD. 21703 Document Version: 3.0

Page 2: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 2

Contents 1 Introduction .......................................................................................................................................... 4

2 Initial setup of CMU. ............................................................................................................................. 4

2.1 CDMA 2000 Signaling Configuration ........................................................................................... 10

3 Preparing a device for testing ............................................................................................................. 11

4 CDMA setup of the R&S CMU200 ....................................................................................................... 13

5 VoLTE setup of the R&S CMW 500 ..................................................................................................... 17

5.1 Powering Up the Box .................................................................................................................. 17

5.2 Configuring the Signal Generator ............................................................................................... 17

5.3 Setting Data Application Control (Appling the Main Configuration Options)............................. 38

6 CMDA setup of the R&S CMW500 ...................................................................................................... 47

Figure 2-1 - CMU Front Panel........................................................................................................................ 4 Figure 2-2 – Overview Screen ....................................................................................................................... 5 Figure 2-3 – BS Signal Tab ............................................................................................................................. 5 Figure 2-4 – Press Network Tab .................................................................................................................... 6 Figure 2-5 – Network Identity Tree ............................................................................................................... 7 Figure 2-6 – RF Setting Tab ........................................................................................................................... 8 Figure 2-7 – Service Configuration Tab ......................................................................................................... 9 Figure 2-8 – Connection Tab ....................................................................................................................... 10 Figure 3-1 - Sticker Placement .................................................................................................................... 11 Figure 3-2 – AVS Sticker Placement ............................................................................................................ 12 Figure 4-1 – Service Class ............................................................................................................................ 13 Figure 4-2 - Sticker Placement .................................................................................................................... 14 Figure 4-3 – Device Registration ................................................................................................................. 14 Figure 4-4 - Handset Volume Adjustment .................................................................................................. 15 Figure 4-5 - Fastening the Phone ................................................................................................................ 15 Figure 4-6 – CMU Screen ............................................................................................................................ 16 Figure 5-1 - CMW 500 Front Panel View ..................................................................................................... 17 Figure 5-2 – Generator Signaling Controller ............................................................................................... 18 Figure 5-3 – LTE Signaling 1 ......................................................................................................................... 19 Figure 5-4 – Measurement Controller ........................................................................................................ 20 Figure 5-5 – Update Measurements ........................................................................................................... 21 Figure 5-6 - Scenario ................................................................................................................................... 21 Figure 5-7 - LTE Signaling 1 ..................................................................................................................... 22 Figure 5-8 Data Application Measurement Overview Tab ......................................................................... 23 Figure 5-9 Connection Status ...................................................................................................................... 24 Figure 5-9 Path ............................................................................................................................................ 25 Figure 5-11 - Data Application Measurement Ping Tab .............................................................................. 26 Figure 5-12 - Data Application Measurement Ping Tab Configuration Option .......................................... 27 Figure 5-13 - Data Application Measurement Iperf Tab ............................................................................ 28 Figure 5-14 - Data Application Measurement Iperf Tab Configuration (part I) ......................................... 29

Page 3: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 3

Figure 5-15 - Data Application Measurement Iperf Tab Configuration (part I) ......................................... 30 Figure 5-16 - Data Application Measurement Throughput Tab .................................................................. 31 Figure 5-17 - Data Application Measurement Throughput Tab Configuration .......................................... 32 Figure 5-18 Data Application Measurement DNS Req Tab ........................................................................ 33 Figure 5-19 Data Application Measurement DNS Req Tab Configuration ................................................. 34 Figure 5-20 Data Application Measurement IP Logging............................................................................ 35 Figure 5-21 - - Data Application Measurement IP Logging Tab Configuration ........................................... 36 Figure 5-22 Data Application Measurement IP Analysis Tab .................................................................... 37 Figure 5-23 Data Application Measurement IP Analysis Tab Configuration .............................................. 38 Figure 5-24 Data Application Measurement Overview ............................................................................. 39 Figure 5-25 – IP Config ................................................................................................................................ 40 Figure 5-26 - DNS ........................................................................................................................................ 41 Figure 5-27 FTP........................................................................................................................................... 42 Figure 5-28 - HTTP ....................................................................................................................................... 43 Figure 5-29 - IMS ......................................................................................................................................... 44 Figure 5-30 –Configuring Voice Over IMS ................................................................................................... 45 Figure 5-31 –When the call begins the telephone symbol next to ringing will begin to rotate. ................ 46 Figure 6-1 –Generate Signaling Controler. ................................................................................................. 47 Figure 6-2 –Connection Status. ................................................................................................................... 48 Figure 2-9 – CDMA Configuration Screen 1. .............................................................................................. 49 Figure 2-10 – CDMA Configuration Screen 2. ............................................................................................ 50 Figure 2-11 – CDMA Configuration Screen 3. ............................................................................................ 51 Figure 2-12 – CDMA Configuration Screen 4. ............................................................................................ 52 Figure 2-13 – CDMA Configuration Screen 5. ............................................................................................ 53 Figure 2-14 – CDMA Configuration Screen 6. ............................................................................................ 54

Page 4: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 4

1 Introduction Spirent Communications AVS is a software and hardware system for use in measuring the end to end quality of mobile devices.

Name Title E-Mail Phone Andrew Boyden Product Manager [email protected] 972-965-1707

Version Author Notes 1.0 Metrico Initial draft.

2.0 Andrew Boyden

3.0 Andrew Boyden Addition of the R&S CMU 500

2 Initial setup of CMU.

Figure 2-1 - CMU Front Panel

1. Turn on the CMU 200.

2. Press “Menu Select”.

3. Expand IMT-2000 Mobile Station.

4. Select “CDMA2000 Cellular”.

5. When done, press the “BS Signal” tab.

Press Menu Select

Select CDMA2000 Cellular

Power On the unit

Page 5: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 5

Figure 2-2 – Overview Screen

Figure 2-3 – BS Signal Tab

6. Under “BS Signal” tab Set channel to 384.

7. Set CDMA Power to -55 dBm.

Select “BS Signal” tab

Page 6: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 6

8. Set the rest of the parameters to match the previous picture..

9. When done press, “Network” tab button.

Figure 2-4 – Press Network Tab

10. Under the Network Tab expand the System Parameters tree.

11. Set System ID Number to 2004.

12. Set the rest of the parameters to match the picture above.

13. Expand the Network Identity tree.

Press Network tab

Page 7: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 7

Figure 2-5 – Network Identity Tree

14. Under the Network Identity tree:

Set the Network ID Number to 65535.

Set the Mobile Country Code to 310.

Expand the Mobile Settings tree.

15. Under the Mobile Settings tree

Set the Mobile Country Code to 310.

Set the Mobile Compatibilities Report to On.

16. Move to AF/RF settings tab.

Page 8: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 8

Figure 2-6 – RF Setting Tab

17. Set RF output to “RF 2”.

18. Press the “Ext. Att. Output” button.

19. Set RF external attenuation output to +10.0 dB.

20. Press the “Ext. Att. Output” button.

21. Set RF external attenuation input to +10.0 dB.

22. Set Speech Encoder to Handset.

23. Set Speech Decoder to Handset.

24. Move on to the “Service Cfg.” settings tab.

AF/RF Settings tab

RF Ext.Att. Ouput

RF Ext. Att. Input

Page 9: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 9

Figure 2-7 – Service Configuration Tab

25. Always enable R/C3/3.

26. Expand the Primary Service Class tree.

27. Expand Service Option 68 tree.

28. Set the Voice Coder to “8k EVRC-B (low)”.

WARNING: if Voice Coder option is non-changeable and says “Echo”, the CMU you are using does NOT

support 8k EVRC-B voice coding and can NOT be used with AVS. Please contact R&S or obtain a CMU

that supports this feature.

29. Expand the Vocoder Configuration tree.

Set the Average Encoding Rate to 6.6 kbps.

Click “Execute” on the Initialize Vocoder if necessary.

30. Set the “Selected Service Option” to Service Option 68.

31. Select “Accept MS Originated Call”. Set it to “Force To Selected Primary Service”.

32. Move on to the “Connections” tab.

Service Cfg. tab

Page 10: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 10

Figure 2-8 – Connection Tab

2.1 CDMA 2000 Signaling Configuration

Connection tab

NOTE: Verify “SO 68” = 8k EVRC B 6.6 kHz

Signal On Button

Page 11: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 11

3 Preparing a device for testing 1. Insert the special Verizon test SIM card.

Note: This card will force the device to only register to the CMU-200 network emulator (instead of a live

base station)

2. Place the provided “AVS Alignment Sticker” on the phone in the following images.

Figure 3-1 - Sticker Placement

WARNING: Verify that the large hole on the alignment sticker completely covers the handset’s earpiece and that none of the handset’s earpiece is obstructed.

Page 12: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 12

More examples of the proper way to place the “AVS Alignment Sticker” on the phone:

Figure 3-2 – AVS Sticker Placement

Note: The large hole on the alignment sticker completely covers the handset’s earpiece and that none of the handset’s earpiece is obstructed.

Warning: Ensure the device is set to maximum volume.

Page 13: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 13

4 CDMA setup of the R&S CMU200

1. Place the device inside the AVS chamber.

2. Close the chamber door.

3. Verify that “Signal On” is the current status. Signal On will appear in the top right corner of the

screen.

4. Verify that you are using Service Option 68. This can be done by looking at the top of the CMU

screen “SO 68” = 8k EVRC B.

5. If the CODEC you wish to test is not shown above, please return to the “Service Cfg.” Tab and

follow the instructions that are pertinent to the CODEC you wish to test.

Figure 4-1 – Service Class

6. Verify “1st Service Class” is set to “Speech Service”.

Page 14: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 14

Figure 4-2 - Sticker Placement

7. Wait for the CMU to “register” the phone.

8. REGISTERED will appear in the top right corner of the screen.

Figure 4-3 – Device Registration

Page 15: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 15

9. When the device is registered, establish a call between the simulator and the UE.

10. Press the “Connect MS” button on the CMU. This will instruct the CMU to call the device under

test. Within several seconds, the mobile will start to ring.

11. Open the AVS chamber.

12. Answer the call on the device.

13. Adjust the handset earpiece volume to maximum volume.

Figure 4-4 - Handset Volume Adjustment

Figure 4-5 - Fastening the Phone

14. Place the device onto the AVS alignment pins using the alignment sticker on the device.

Note: The device’s screen should be facedown.

15. The CMU screen will now look like the following screen.

Page 16: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 16

Figure 4-6 – CMU Screen

16. Turn on Q-QPSK..

17. Close the chamber door.

You are ready to execute an AVS test.

Page 17: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 17

5 VoLTE setup of the R&S CMW 500

5.1 Powering Up the Box Perform the following steps to establish the initial configuration of your Rhodes and Schwarz CMW500 unit.

1. Press the power button on the front panel as shown in the following image.

Figure 5-1 - CMW 500 Front Panel View

2. On the box, perform the following steps.

3. Click the power button. Wait for the system to cycle up. A splash screen displays prompting you

to configure either measurements or the signal generator. Spirent Technologies recommends you configure the signal generator first.

5.2 Configuring the Signal Generator 1. Press the signal generator key (shown in the green circle) on the front panel and a screen like the

following appears.

Power Switch

Page 18: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 18

Figure 5-2 – Generator Signaling Controller

2. Set the LTE Signaling 1option to On (checked). At the bottom of the screen click the LTE 1 Signaling option and a screen like the following appears.

Page 19: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 19

Figure 5-3 – LTE Signaling 1

3. Verify that the information on your screen matches exactly what is presented on this screen.

Downlink Channel: 5230 Uplink: 2320 Cell Bandwidth: 10.0 MHz RS EPRE: -60.0 dBM 15kHz PUSCH Open Loop Nom power: 0 dBm PUSCH Closed Loop Target Power: 0.0 dBm Sched: RMS #RB Downlink: 50 #RB Uplink: 50 RB Pos/Start RB Downlink: low RB Pos/Start RB Uplink: low Modulation Uplink: OPSK Modulation Downlink: OPSK

4. When you are satisfied that all the information is exact, press the measurement button on the

front panel of the unit and a screen like the following appears.

Page 20: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 20

Figure 5-4 – Measurement Controller

5. Check the Data Appl, Measurement 1 option.

6. Select Audio Measurement 1 and the following screen displays.

Page 21: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 21

Figure 5-5 – Update Measurements

7. From this screen use the Scenario drop down option to select External Analog Speech Analysis and select External Analog Speech Analysis..

Figure 5-6 - Scenario

8. Verify that all the set values match what appears in this screen.

Signaling: No Connection Input Level Full-Scale (Peak): 1.573V High Pass Filter: 6 Hz Connector: Af-1

Page 22: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 22

Output Level Full-Scale (Peak): 1.573 V

9. Click LTE Signaling 1 and the following screen displays.

Figure 5-7 - LTE Signaling 1

10. Enter all the values shown in this screen into your system.

Operating Band: Band 13 Channel Downlink: 5230 Ch Channel uplink: 2320 Ch Frequency Uplink: 751.0 MHz Frequency Downlink 782.0 MHz Cell Bandwidth: 10. MHz RS EPRE: -60.0 dBm 15 kHz PUSCH Open Loop Nom Power: 0 dBm PUSCH Closed loop Target Power: 0.0 dBm Sched: RMC #RB Downlink: 50 #RB Uplink: 50 RB Pos./Start RB uplink: low RB Pos./Start RB downlink: low Modulation uplink: QPSK Modulation downlink: QPSK

Page 23: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 23

11. Select Data 1 Meas and a screen like the following displays.

Figure 5-8 Data Application Measurement Overview Tab

12. Enter all the values shown in this screen into your system.

13. Enable speech codec can only be turned on or off if the LTE Signal is in the OFF mode.

14. To enable speech code, open the connection status window.

Page 24: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 24

Figure 5-9 Connection Status

15. Match the entries in the screen and click Config. A screen like the following displays.

Page 25: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 25

Figure 5-10 Path

16. Verify 1 Cell – 1 RF out.

Page 26: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 26

17. Select the Ping Tab. Note that you can configure these tabs in any order. This document goes left to tight for readability.

18. Open the Ping tab and a screen like the following displays.

Figure 5-11 - Data Application Measurement Ping Tab

19. Enter all the values shown in this screen into your system. Conf Destination IP: 172.22.1.100 Interval: 1000 Timeout: 2 Payload: 100 Ping count: 100

20. Click the Config tab on the bottom right and a screen like the following appears.

Page 27: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 27

Figure 5-12 - Data Application Measurement Ping Tab Configuration Option

21. Enter all the values shown in this screen into your system.

Destination IP: 172.22.1.100 Interval: 1000 ms Timeout: 2 Payload: 100 Bytes Ping count: 100

22. Open the I Perf tab and a screen like the following appears.

Page 28: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 28

Figure 5-13 - Data Application Measurement Iperf Tab

23. Enter all the values shown in this screen into your system.

Select RAN: LTE Signaling 1 Test Duration: 1000 Server, select 1 TCP. Clients select 1 TCP with parallel

24. Click Config on the lower right and a screen like the following appears.

Page 29: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 29

Figure 5-14 - Data Application Measurement Iperf Tab Configuration (part I)

25. Enter all the values on your system match the values shown in the screen.

Test Duration: 1000 Packet Size: 1470 Servers, use TCP on Port 5001 Clients, use TCP on {Port 5001 UE IP Address: 172.22.1.100 Parallel Conn: 1

26. Scroll down and the bottom half of the screen displays.

Page 30: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 30

Figure 5-15 - Data Application Measurement Iperf Tab Configuration (part I)

27. Enter all the values shown in this screen into your system.

28. Select Throughput and a screen like the following appears.

Page 31: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 31

Figure 5-16 - Data Application Measurement Throughput Tab

29. Enter all the values shown in this screen into your system.

30. Click Config on the lower right and a screen like the following appears.

Page 32: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 32

Figure 5-17 - Data Application Measurement Throughput Tab Configuration

31. Enter all the values shown in this screen into your system.

Interval:1 Max array size: 1000 Traces visibility, vDAU Overall throughput is enables for the uplink and the downlink

32. Click the DNS req tab and a screen like the following appears.

Page 33: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 33

Figure 5-18 Data Application Measurement DNS Req Tab

33. Enter all the values shown in this screen into your system.

34. Click Config on the lower right and a screen like the following appears.

Page 34: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 34

Figure 5-19 Data Application Measurement DNS Req Tab Configuration

35. Enter all the values shown in this screen into your system.

Max. Index Count: 1000

36. Click IP logging and a screen like the following appears.

Page 35: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 35

Figure 5-20 Data Application Measurement IP Logging

37. Enter all the values shown in this screen into your system.

38. Click Config on the lower right and a screen like the following appears.

Page 36: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 36

Figure 5-21 - - Data Application Measurement IP Logging Tab Configuration

39. Enter all the values shown in this screen into your system.

Logging Interface: U-Plane IP File size: 0 Packet Counter: 0

40. Click IP Analysis and a screen like the following appears.

Page 37: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 37

Figure 5-22 Data Application Measurement IP Analysis Tab

41. Enter all the values shown in this screen into your system. Select RAN: LTE Signaling 1

42. Click Config on the lower right and a screen like the following appears.

Page 38: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 38

Figure 5-23 Data Application Measurement IP Analysis Tab Configuration

43. Enter all the values shown in this screen into your system.

TCP Analysis Settings: 90.0 % TCP Retransmission Threshold: 10% TCP Overhead Threshold: 50%

5.3 Setting Data Application Control (Appling the Main Configuration Options) From Data Print Measure select Configure on the upper right and the following screen displays.

Page 39: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 39

Figure 5-24 Data Application Measurement Overview

From this screen perform the following options.

1. Enter all the values shown in this screen into your system.

Domain Name Service (DNS): Off File Transfer Protocol Service (FTP: Off Hypertext Transfer Protocol (HTTP): Off IP Multimedia Service (IMS) On IMS server Type: intern IMS Mobile Status: registered Ip Address: fc01: abab:cdcd:efe1

2. Click IP Config and the following appears.

Page 40: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 40

Figure 5-25 – IP Config

3. Enter all the values shown in this screen into your system.

4. Click DNS Config and a screen like the following appears.

Page 41: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 41

Figure 5-26 - DNS

5. Enter all the values shown in this screen into your system.

6. Click FTP and a screen like the following appears.

Page 42: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 42

Figure 5-27 FTP

7. Enter all the values shown in this screen into your system.

FTP Service Type: FTP Server

8. Click HTTP and a screen like the following appears.

Page 43: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 43

Figure 5-28 - HTTP

9. Enter all the values shown in this screen into your system.

10. Click IMS and a screen like the following appears.

Page 44: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 44

Figure 5-29 - IMS

11. Enter all the values shown in this screen into your system. 12. To configure Voice over IMS and create an outgoing call click Config and a screen like the

following displays.

Page 45: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 45

Figure 5-30 –Configuring Voice Over IMS

13. Enter all the values shown in this screen into your system. 14. Verify or enter that the Call Type is Audio (not Video).. 15. AMR must equal wideband. 16. The AMR Code must be checked and equal to 12.65.

Page 46: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 46

Figure 5-31 –When the call begins the telephone symbol next to ringing will begin to rotate.

17. Push the call button

Page 47: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 47

6 CMDA setup of the R&S CMW500

To configure the CDMA Signaling options, perform the following steps.

1. Press the Sig Gen key on the front panel, select “CDMA2000 Signaling”

Figure 6-1 –Generate Signaling Controler.

2. From the front CDMA screen select the Config button in the lower right hand corner and a

screen like the following displays.

Page 48: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 48

Figure 6-2 –Connection Status.

3. Verify you have the same settings as are displayed on this screen.

4. Click Config and a screen like the following displays.

Page 49: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 49

Figure 6-3 – CDMA Configuration Screen 1.

5. Configure the CMW per the following screen shots.

Page 50: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 50

Figure 6-4 – CDMA Configuration Screen 2.

Page 51: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 51

Figure 6-5 – CDMA Configuration Screen 3.

Page 52: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 52

Figure 6-6 – CDMA Configuration Screen 4.

Page 53: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 53

Figure 6-7 – CDMA Configuration Screen 5.

Page 54: Acoustic Verification System (AVS) CMU and Rohde & Schwarz ... · 4 CDMA setup of the R&S CMU200 ... Figure 5-31 –When the call begins the telephone symbol next to ringing will

Copyright © Spirent Communications, Inc. 2014 54

Figure 6-8 – CDMA Configuration Screen 6.

This completes the configuration.