15
A/C SYSTEM SERVICE 1 A/C manifold gauge set Manifold valves Hose end valves Performance test Pressure diagnosis Manifold purging and disconnect

A/C SYSTEM SERVICE 1 A/C manifold gauge set Manifold valves Hose end valves Performance test Pressure diagnosis Manifold purging and disconnect

Embed Size (px)

Citation preview

Page 1: A/C SYSTEM SERVICE 1  A/C manifold gauge set  Manifold valves  Hose end valves  Performance test  Pressure diagnosis  Manifold purging and disconnect

A/C SYSTEM SERVICE

1

A/C manifold gauge set Manifold valves Hose end

valves Performance

test Pressure

diagnosis Manifold

purging and disconnect

Page 2: A/C SYSTEM SERVICE 1  A/C manifold gauge set  Manifold valves  Hose end valves  Performance test  Pressure diagnosis  Manifold purging and disconnect

2

Page 3: A/C SYSTEM SERVICE 1  A/C manifold gauge set  Manifold valves  Hose end valves  Performance test  Pressure diagnosis  Manifold purging and disconnect

THE NATIONAL REFRIGERANT RECYCLING RULE WAS PROPOSED DECEMBER 10,1992 AND AN ...THE RECOVERY OR RECOVERY/RECYCLING EQUIPMENT MUST BE CERTIFIED BY AN APPROVED 

3

Page 4: A/C SYSTEM SERVICE 1  A/C manifold gauge set  Manifold valves  Hose end valves  Performance test  Pressure diagnosis  Manifold purging and disconnect

A/C SYSTEM SERVICE

Recovery Evacuation Recharging Leak Check Freon Quality Robinair 347788

Demo

4

Page 5: A/C SYSTEM SERVICE 1  A/C manifold gauge set  Manifold valves  Hose end valves  Performance test  Pressure diagnosis  Manifold purging and disconnect

REFRIGERANT IDENTIFICATION

Follow equipment manufacturer’s instructions

Do not recover refrigerant with sealers

5

Section 609 Purity Standards (hand out)Refrigerant Purity Standards-handout.docx

Identify

Page 6: A/C SYSTEM SERVICE 1  A/C manifold gauge set  Manifold valves  Hose end valves  Performance test  Pressure diagnosis  Manifold purging and disconnect

REFRIGERANT PASS/FAILMUST BE 98% TO RECYCLE

6

Page 7: A/C SYSTEM SERVICE 1  A/C manifold gauge set  Manifold valves  Hose end valves  Performance test  Pressure diagnosis  Manifold purging and disconnect

A/C SEALANT DETECTOR MODEL 

AC Sealant Detection7

Page 8: A/C SYSTEM SERVICE 1  A/C manifold gauge set  Manifold valves  Hose end valves  Performance test  Pressure diagnosis  Manifold purging and disconnect

REFRIGERANT RECOVERY

Connect recycler to vehicle service ports

Set machine to recover If recovery equipment

does not automatically shut off- recover until system drops into slight vacuum

Shut off valves and observe pressures for 5 minutes

If pressure increases-repeat recovery

8

Page 9: A/C SYSTEM SERVICE 1  A/C manifold gauge set  Manifold valves  Hose end valves  Performance test  Pressure diagnosis  Manifold purging and disconnect

THE FLOW DIAGRAM FOR A RECOVERY/ RECYCLING MACHINE SHOWING THE INTERNAL COMPONENTS AND THE PATH THAT REFRIGERANT TAKES DURING RECOVERY AND RECYCLING. (COURTESY OF ROBINAIR, SPX CORPORATION)

9

Page 10: A/C SYSTEM SERVICE 1  A/C manifold gauge set  Manifold valves  Hose end valves  Performance test  Pressure diagnosis  Manifold purging and disconnect

EVACUATION

Drain and measure system oil recovered in recycler

Evacuate system after leak check has been performed

If system has been exposed to moisture:

Evacuate until: 500 microns 29.2 in. 20-30 mins. minimum

Add amount of oil removed

10

Page 11: A/C SYSTEM SERVICE 1  A/C manifold gauge set  Manifold valves  Hose end valves  Performance test  Pressure diagnosis  Manifold purging and disconnect

RECHARGE

Determine system capacity Recharge system If recycler cannot fully charge

system (temp or pressure too high):

Shut off both manifold valves Start engine and turn on A/C

max Open doors/windows Charge remainder of refrigerant

through low side port without allowing pressure to exceed 50 psi

Close both valves and complete performance check

Disconnect hoses from vehicle

11

Page 12: A/C SYSTEM SERVICE 1  A/C manifold gauge set  Manifold valves  Hose end valves  Performance test  Pressure diagnosis  Manifold purging and disconnect

THE BUBBLES IN A SIGHT GLASS WILL DISAPPEAR AT A POINT LOWER THAN THE PROPER CHARGE AMOUNT. HIGH-SIDE PRESSURE WILL INCREASE AT A POINT THAT THE SYSTEM IS ALREADY OVERCHARGED. (COURTESY OF TOYOTA MOTOR SALES USA, INC.)

12

Page 13: A/C SYSTEM SERVICE 1  A/C manifold gauge set  Manifold valves  Hose end valves  Performance test  Pressure diagnosis  Manifold purging and disconnect

13

Page 14: A/C SYSTEM SERVICE 1  A/C manifold gauge set  Manifold valves  Hose end valves  Performance test  Pressure diagnosis  Manifold purging and disconnect

GO TO GOOGLE-TYPER134 PRESSURE CHART 14

Page 15: A/C SYSTEM SERVICE 1  A/C manifold gauge set  Manifold valves  Hose end valves  Performance test  Pressure diagnosis  Manifold purging and disconnect

ROBINAIR R & R MACHINE.PDF

15