40
Replacement Parts List No. 057112600 Revision M 03/2017 AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW 06 - 19 AEW, EW 12 - 19 AHW, BHW, CHW, HW 09 - 93 AVW, BVW, CVW, VW 01 - 93 Vintages A, B, C Last Manufactured: 1980 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com

AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

  • Upload
    lamphuc

  • View
    501

  • Download
    12

Embed Size (px)

Citation preview

Page 1: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Replacement Parts List No. 057112600 Revision M 03/2017

AAF

Enercon Heat PumpACW, AWW, BCW, BWW, CWW, CW, WW

06 - 19AEW, EW

12 - 19AHW, BHW, CHW, HW

09 - 93AVW, BVW, CVW, VW

01 - 93Vintages A, B, C

Last Manufactured: 1980

To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com

Page 2: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 2

ContentsParts List Revision History.................................................................................................................................. 3Model Number Breakdown- ACW....................................................................................................................... 4Model Number Breakdown- AEW ....................................................................................................................... 5Model Number Breakdown- AWW/BWW ............................................................................................................ 6Model Number Breakdown- CWW ..................................................................................................................... 7ACW, AEW, AWW, BWW, CWW Components- Refrigeration Circuit ................................................................. 8ACW, AEW, AWW, BWW, CWW Components- Fan Components, Controls ...................................................... 9Model Number Breakdown- BCW .................................................................................................................... 10BCW- Compressor Section .........................................................................................................................11, 12BCW- Chassis and Fan Deck ..................................................................................................................... 13- 15BCW- Cabinet Assembly .................................................................................................................................. 16BCW- Damper Assembly .................................................................................................................................. 17BCW- Night Setback and Fuses ....................................................................................................................... 18BCW- Front Panel- Vinyl Clad, 2- Way Motorized Hot Water Valve ................................................................. 19BCW- Wall Thermostat and Cordsets, Thermostat Accessories and Aquastats .............................................. 20BCW- Enercon Safety & Operating Control Assembly ............................................................................... 21- 23BCW- Controls- Unit Mounted Thermostat w/ Manual Changeover ................................................................. 24BCW- Controls- Unit Mounted Thermostat w/ Automatic Changeover ............................................................. 25BCW- Controls- Wall Mounted Thermostat ...................................................................................................... 26BCW- Controls- Label Location ........................................................................................................................ 27BCW- Master & Slave Control Box ................................................................................................................... 28BCW- Night Setback Central Control Panel ..................................................................................................... 29Model Number Breakdown- AHW, BHW .......................................................................................................... 30Model Number Breakdown- AVW, BVW, CVW ................................................................................................. 31AHW, BHW, CHW, AVW, BVW, CVW- Sizes 09- 26- Refrigeration Circuit ....................................................... 32AHW, BHW, CHW, AVW, BVW, CVW- Sizes 09- 26- Fan Components, Controls ........................................... 33AHW, BHW, CHW, AVW, BVW- Sizes 33- 51- Refrigeration Circuit ................................................................. 34AHW, BHW, CHW, AVW, BVW, CVW- Sizes 33 -51- Fan Components, Controls ........................................... 35AHW, BHW, CHW, AVW, BVW- Sizes 62- 186- Refrigeration Circuit ............................................................... 36AHW, BHW, CHW, AVW, BVW- Sizes 62- 186- Fan Components, Controls .................................................... 37Accessory PanelsMaster/Slave Control Box, Night Setback Control Panel, System Safety and Operating Panel (SSOP) Repeater Panel .................................................................. 38 Current Courier .......................................................................................................................................... 39 Zone-All ...................................................................................................................................................... 40

Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330

Page 3: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 3

Revision Date Description New 04/88 New. Drafted from 09/81 through 04/88. A 08/02 Convert to electronic format. Part numbers converted to current McQuay format. Reformat book to put the unit model breakdowns in front of their respective parts lists (divided into design categories). CW/EW/WW- Added notes for sizes 06/15/19 compressor kits and sizes 15/19 compressor mounting and filter drier for burnout kits. Changed reversing valves and added notes. Corrected or updated part numbers for sizes 09/12 capillary tube, blower motor bracket, TH-1 manual c/o stat. BCW- Correct or update part numbers for 115V fan motor, size 15 208V compressor, 15A fuse, TH2 and TH1 thermostat. Combined night setback central control sections. Removed soldering and brazing materials. Changed reversing valves and added notes. HW/VW - Changed reversing valves and added notes. Correct or update part numbers for size 19 208/230/3 compressor, size 19 220/50 capacitor, size 26 capacitors, size 51 3Ø compressor contactor, size 33 460V blower motor, size 33 3Ø motor capacitor, size 51 motor capacitors, manual changeover stat, sizes 62-186 compressor grommets and sleeves, size 124 air coil, size 186 230/460V fan motor, sizes 62/93 fan capacitor, size 124 fan wheel, sizes 124/ 186 fan motor overload, size 62 3Ø compressor contactor, SSOP panel R1 relay. Added retrofit kits and components for sizes 62/93 208/240V fan motor. Added components for size 33 460V blower motor retrofit kit. Added compressor grommet and sleeve part numbers for size 51 compressor kits. Added kit components for size 33 460V fan motor. Added filter drier for burnout kits. B 12/02 Page 8 - Reversing Valve for CW09, WW09, CW12,EW12, WW12 part number was changed from 067285201 to 067785201. C 06/03 Page 37- Controls: Reset Relay & Reversing Valve Relay-Model #VW124(01) & VW186(02) part number 4EWJ6987 was corrected to 4EWJ6967. D 08/03 Blower Motor, HW,VW19& HW,VW 26, 265/1/60 p/n JBDQ5780 to JWDQ5780. E 04/04 Page 37 - Blower Motor-HW93/VW93 p/n PMCQ5876A to OVDQ5857K2. F 04/05 Page 37 - Blower motor for 208/230, models HW/HV93 change to 'Not Applicable'. G 01/06 Page 8 - Reversing Valve and Reversing Valve Solenoid have footnote #9 added. Page14 - Bub #50-Reversing Valve and Reversing Valve Coil have footnote #2 added. Page 25 - Spring Clip-Cap Tube p/n 4DDZ6424 was changed to 106456801. Page 32 - Reversing Valve and Solenoid Coil have footnote #4 added. Page 34 - Reversing Valve units built before 2/76 have note #5 added. Page 36 - P/N for Reversing Valve for units dated 1/81 & Later with model number HW93 was changed from 066533501 to 106694107. Part # for Solenoid Coil, Rev. Valve for units dated 1/81 & Later (460/3) with model #HW93 was changed from 067010001 to 106694207. Page 37 - Rev. Valve Relay for VW124 & VW186 change p/n 4EWJ6967 to 4EWJ5716. H 12/07 Page 14 - Bub#50 Reversing Valve/size 12 pn change from 067784501 to 067284501. J 120/08 Page 37 - Change Motor Mounting Bracket part numbers. K 04/10 Page 8- Change compressor 208/230V p/n WXA190758 footnote from 2 to 3. Change compressor 277V p/n WXA150759 footnote from 3 to 2. L 11/13 Page 30- Added Unit Size 19. Added note to Voltage Code 7. Page 31- Added Unit Size 19, 124 (01) and 186 (02). Added note to Voltage Code 7. Added codes for last digit, was Always =0. M 03/17 Rebrand Daikin. Pages 2, 30, 32, 33, 35- Add CHW. Page 36- Change water coils p/n WR546A to WRF546A, WR554A to WRF554A, WR550A to WRF550A, and WR551A to WRF551A.

Parts List Revision History

Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330

Page 4: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 4

NomenclatureModel Number Breakdown

ACWDate- 1/1/86

S S A CW 19 2 1 2

ConstructionS= StandardZ= Non- Standard

CabinetS= Standard Unit With CabinetC= Standard Unit Less CabinetD= Service Chassis

Design 'A'

Model (Console Enercon)

Unit Size (1000's BTU)60 hz= 06, 09, 12, 15, 1950 hz= 06, 09, 12, 19

Voltage & PhaseHeat Pump Only1= 120/60/12= 208/240/60/13= 277/60/18= 220/240/50/1

Control1= Unit Mounted Stat- Manual C/O2= Unit Mounted Stat- Auto C/O3= Wall Mounted Stat

Damper0= None1= Manual2= 25% Motorized- 24V3= 25% Motorized- 220V

Page 5: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 5

NomenclatureModel Number Breakdown

AEWDate- 1/1/86

S A A A A EW 19 2 1 2

Cabinet- ToppingA= VinylB= Formica

Cabinet- DepthA= Standard- 13 5/8"B= Standard- 16 5/8"C= D/S- 16 5/8"

Cabinet- Inlet Plenum (O.D.A.)A= Left HandB= Right HandC= CenterD= None

Design 'A'

Model EW (Enercon Classroom

Unit)

Unit Size (100's BTU)12, 15, 19

Voltage & Phase2= 208/240/60/13= 277/60/1

ConstructionS= StandardZ= Non- Standard

Control1= Unit Mounted Stat- Manual C/O2= Unit Mounted Stat- Auto C/O3= Wall Mounted Stat 24V

Damper0= None1= Manual2= 25% Motorized- 24V

Page 6: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 6

NomenclatureModel Number Breakdown

AWW/BWWDate- 1/1/86

S L A WW 09 2 2 2 2 0

Control Option0= None1= Unit Setback2= Remote Setback

CabinetL= Standard Unit With Cabinet- LH End CompartmentR= Standard Unit With Cabinet- RH End CompartmentC= Chassis OnlyD= Service Chassis (Design "A" Only)S= Standard Unit With Cabinet

Damper (Design B Only)0= None1= Manual2= Motorized w/o Switch3= Motorized w/Switch

DesignA= Design "A"B= Design "B"

Model WW (Series E

Nelsonaire Water Cooled)

Unit Size (100's BTU)06, 09, 12, 15, 19

Voltage & Phase1= 120/60/1 (sizes 06 & 09 only)2= 208/60/13= 240/60/14= 277/60/1

ConstructionS= StandardZ= Non- Standard

Heating or Cooling1= Cooling Only2= 1.8 KW3= 2.4 KW4= 3.2 KW5= 4.27 KW (sizes 12- 19 only)6= 4.87 KW (sizes 12- 19 only)

Day Control1= Unit Mounted- Manual C/O2= Unit Mounted- Auto C/O3= Unit Mounted- Cooling Only4= Wall Mounted- Manual C/O5= Wall Mounted- Auto C/O6= Wall Mounted- Cooling Only7= Pneumatic Controls by Others

Page 7: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 7

NomenclatureModel Number Breakdown

CWWDate- 1/1/86

S A A A A C WW 09 5 1 1 0 0

Control0= None

Setback ControlsA= NoneB= Unit Night Stat

Damper0= None1= Manual2= Motorized

Design C

Model WW (Series E

Nelsonaire Water Cooled)

Unit Size (100's BTU)06, 09, 12, 15, 19

Voltage & Phase1= 115/60/1- Cooling2= 208/230/60/1- Cooling3= 265/60/1- Cooling5= 208/60/1- Electric Heat6= 230/60/1- Electric Heat7= 265/60/1- Electric Heat

ConstructionS= StandardZ= Non- Standard

Control0= Unit Mounted- Cooling Only1= Unit Mounted- Manual C/O2= Unit Mounted- Auto C/O

Heating Mode0= None1= 1.7 KW2= 2.25 KW3= 2.8 KW4= 3.0 KW5= 3.75 KW6= 4.0 KW7= 5.0 KW

ControlA= None

TDR (Anti- Short Cycle)A= NoB= Yes

CabinetA= Standard Unit w/Cabinet- LH Stub UpB= Standard Unit w/Cabinet- RH Stub UpC= Chassis Only- LH Stub UpD= Chassis Only- RH Stub UpF= Free Standing unit w/CabinetG= Climate Director- LH Stub UpH= Climate Director- RH Stub Up

Page 8: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 8

ACW, AEW, AWW, BWW, CWW ComponentsRefrigeration Circuit

Compressor 115 Volt WB1000DK YB114 N/A N/A N/A 208/230 Volt WB1001 YB115 WB1003 WXA1507581 WXA1907583

277 Volt WB1002 YB116 WB1004 WXA1507592 WXA1907594

220/240/50/1 Volt WB1026 YB140 WB1020 WB-1027 N/A Compressor Mounting Grommet (4) YB126 YB126 YB126 YB1265 YB1265

Sleeve (2) YB127 YB127 YB127 YB1275 YB127 5

Compressor Capacitor6

115 Volt 4ERA7495 4ERA7500 N/A N/A N/A 208/230 Volt 4ERA7495 4ERA7495 4ERA7506 4ERA7498 4ERA7500 277 Volt 4ERA7506 4ERA7506 4ERA7506 4ERA7508 4ERA7510 220/240/50/1 Volt 4ERA7495 4ERA7500 4ERA7498 4ERA7500 N/A Reversing Valve7,9 067284401 067785201 067785201 067284501 067284501 Reversing Valve Solenoid7,9

24 Volt 067010001 067010001 067010001 067010001 067010001 115 Volt 066541901 066541901 N/A N/A N/A 208/230 Volt 066541903 066541903 066541903 066541903 066541903 265 Volt 066541904 066541904 066541904 066541904 066541904 Freezestat (After 6/78) 4ELN6719 4ELN6719 4ELN6719 4ELN6719 4ELN6719 (Prior 6/78) WXA190111 WXA190111 WXA190111 WXA190111 WXA190111 Capillary Tube WL1105A 063090901 06090901 WL1107B WL1108A Strainer WR1085A WR1085A WR1084A WR1210 WR1210 Air Coil WRF876 WRF874 WRF877 WRF875 WRF878 Water Coil (After 12/76) WR1050F WR1051F WR1052F WR1053F WR1054F (Until 9/76) WRF561 WRF562 WRF563 WRF564 WRF565 Water Regulating Valve (WW only) 4FAV5998A 4FAV5998A 4FAV5998A 4FAV5998A 4FAV5998A Burnout Kit8

115 Volt WXA060107 N/A N/A N/A N/A 208/240/277 Volt WXA090107 WXA120107 WXA120107 WXA190107 WXA190107

N/A = Not Applicable.1 This compr. kit includes mtg, tubing & instruct. to retrofit a new compr. in place of the originally installed compr. The new compr. only is p/n WB1128.2 This compr. kit includes mtg, tubing & instruct. to retrofit a new compr. in place of the originally installed compr. The new compressor only is p/n WB1130.3This compr. kit includes mounting, tubing & instruct. to retrofit a new compr. in place of the originally installed compr. The new compr. only is p/n 802003426.4 This compr.kit includes mounting, tubing & instruct. to retrofit a new compr. in place of the originally installed compr. The new compr. only is p/n 802003427.5 These grommets & sleeves are used for the original compr. If grommets & sleeves are required for the retrofit compr., use (4) grommet p/n: 802007329 & (4) sleeve p/n: 802003114.6 When ordering any of these capacitors a bracket must also be ordered. EW & WW units use YE1038; CW units use WE748A.7 The original Ranco reversing valves are no longer manufactured. The p/n listed above are the replacements. If an original reversing valve or coil needs to be replaced, both replacement components must be ordered. Old coils do not fit new valves. New coils do not fit old valves.8 Kit contains filter dryer WX1090.9 When the reversing valves listed above are no longer available replace them with the following p/n: 106694121 (size 06), 106694122 (sizes 15 & 19). Sizes 09 &12 continue to use the valve listed above. A new solenoid must be ordered for a new style valve. The solenoid is p/n: 106694207 (277V), 106694203 (115V), 106694204 (208/230V) or 106694205 (265V).

Description Unit Model Number CW06 CW09 CW12 CW15 CW19 EW12 EW15 EW19 WW06 WW09 WW12 WW15 WW19

Page 9: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 9

ACW, AEW, AWW, BWW, CWW ComponentsFan Components

Blower Motor 115 Volt EAQD5911A EAQD5911A N/A N/A N/A 208/230 Volt EBDQ5912A EBDQ5912A EBDQ5914A EBDQ5916A EBDQ5916A 277 Volt EWDQ5913A EWDQ5913A EWDQ5915A EWDQ5917A EWDQ5917A 220-240/50/1 Volt EMDQ5832 EMDQ5832 EMDQ5836 EMDQ5839 N/A Blower Inlet Ring YF6 YF6 YF6 YF6 YF6 Motor Mounting Bracket WC1277 WC1277 WC1277 WC1277 WC1277 Fan Wheel WF1003 WF1003 WF1003 WF1003 WF1003

Reset Relay 115 Volt 028036200 028036200 N/A N/A N/A 208/230 & 220/240 Volt 4EWJ5681 4EWJ5681 4EWJ5679 4EWJ5679 4EWJ5679 277 Volt 4EWJ5677 4EWJ5677 4EWJ5677 4EWJ6051 4EWJ6051 Fan Relay (R-4) 24 Volt 4EWJ5608 4EWJ5608 4EWJ5608 4EWJ5608 4EWJ5608 High Pressure Switch 4EMB5471C 4EMB5471C 4EMB5471C 4EMB5471C 4EMB5471C Pushbutton Switch Unit Mounted Thermostat 4EAL1927C 4EAL1927C 4EAL1927C 4EAL1927C 4EAL1927C Auto Changeover Supplier (G.E.) #ASP3125-347 & 338 Wall Mounted Thermostat 4EAL1927C 4EAL1927C 4EAL1927C 4EAL1927C 4EAL1927C Auto & Manual Changeover Supplier (G.E.) #ASP3125-347 & 338 Unit Mounted Thermostat 4EAL5499A 4EAL5499A 4EAL5499A 4EAL5499A 4EAL5499A Manual Changeover Supplier (G.E.) #ASP5124-371 Unit Mounted Thermostat Knob 4EBZ1066 4EBZ1066 4EBZ1066 4EBZ1066 4EBZ1066 Thermostat (TH-1) 2

Wall Mtd. Manual C/O T'stat 4ELN9144 4ELN9144 4ELN9144 4ELN9144 4ELN9144 Wall Mtd. Manual C/O Subbase 4ELN7456 4ELN7456 4ELN7456 4ELN7456 4ELN7456 Wall Mtd. Auto C/O T'stat3 4ELN7546 4ELN7546 4ELN7546 4ELN7546 4ELN7546 Subbase 4ELN5494A 4ELN5494A 4ELN5495A 4ELN5494A 4ELN5494A Unit Mtd. Manual Changeover 4ELN7977 4ELN7977 4ELN7977 4ELN7977 4ELN7977 Unit Mtd. ACO (after 5/77) 4ELN6959 4ELN6959 4ELN6959 4ELN6959 4ELN6959 Unit Mtd. ACO (prior 5/77) WXA190112 WXA190112 WXA190112 WXA190112 WXA190112 Transformer 115V/24 Volt 4EPC7356 4EPC7356 N/A N/A N/A 208-230 & 220-240/24 Volt 4EPC7357 4EPC7357 4EPC7357 4EPC7357 4EPC7357 277/24 Volt 4EPC7358 4EPC7358 4EPC7358 4EPC7358 4EPC7358

Description Unit Model Number CW06 CW09 CW12 CW15 CW19 EW12 EW15 EW19 WW06 WW09 WW12 WW15 WW19

Controls Description Unit Model Number CW06 CW09 CW12 CW15 CW19 EW12 EW15 EW19 WW06 WW09 WW12 WW15 WW19

Notes:N/A = Not Applicable.1 Original Robertshaw Manual C/O Stat no longer available. When replacing, order new stat and subbase.2 Honeywell T872 Stat no longer available. When replacing with T874, Stat and Subbase must both be ordered.

Page 10: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 10

NomenclatureModel Number Breakdown

BCWDate- 1/1/86

S L B CW 19 2 1 2 0 0 0

ConstructionS= StandardZ= Non- Standard

CabinetL= Standard Unit With Cabinet- LH End CompartmentR= Standard Unit With Cabinet- LH End CompartmentC= Chassis OnlyE= Classroom Enclosure (sizes 12- 19 only)

Design 'B'

Model (Console Enercon)

Unit Size (1000's BTU)06, 09, 12, 15, 19

Voltage & PhaseHeat Pump Only1= 120/60/12= 208/240/60/13= 277/60/1

Control1= Unit Mounted Stat- Manual C/O2= Unit Mounted Stat- Auto C/O3= Wall Mounted Stat

Damper0= None1= Manual2= Motorized- no switch3= Motorized- with switch

Setback Control0= None1= Unit Mounted2= Remote

Override Timer0= None1= Override Timer

Fuses0= None1= Fuses

Page 11: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 11

20

22

3154

2125

25

7

3

15

6

1721

25

2 5

7

19

20

22

BCWCompressor Section

Diagrams

Size 19

Sizes 06 thru 15

6

18

Page 12: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 12

2 Tube, Suction (R.V. to Comp.) WL1357 WL1357 WL1357 WL1350 WL1410 3 Tube, Discharge WL1340 WL1340 WL1340 WL1354 WL1411 4 Tube, Receiver N/A N/A N/A N/A WL1475 5 Tube, Process YL46 YL46 YL-46 YL46 YL46 6 Tube, Strainer to Water Coil WL1472 WL1472 WL1472 WL1472 WL1472 7 Strainer to Cap Tube WL1473 WL1473 WL1473 WL1473 WL1474 15 Compressor 120/60/1 WB1053 YB154 N/A N/A N/A 208/240/60/1 WB1054 YB155 YB159 WB1128 WB1090 277/60/1 WB1055 YB157 YB161 YB164 WB1091 N/S Capacitor 120/60/1 4ERA7307 4ERA7310 N/A N/A N/A 208/240/60/1 4ERA7305 4ERA7306 4ERA7305 4ERA7307 4ERA7307 277/60/1 4ERA7305 4ERA7311 4ERA7305 4ERA7308 4ERA7312 N/S Bracket-Capacitor Mounting 120/60/1 WE748 WE749 N/A N/A N/A 208/240/60/1 WE748 WE748 WE748 WE748 WE748 277/60/1 WE749 WE750 WE749 WE749 WE750 17 Plate, Compressor Mounting YB117 YB117 YB117 YB117 N/A 18 Spring YB118 YB118 YB118 YB118 N/A 19 Lockwasher 4WBA1560 4WBA1560 4WBA1560 4WBA1560 N/A 20 Nut, Flange (5/16-18)1 4NHA5029 4NHA5029 4NHA5029 4NHA5029 4NHA5029 21 Grommet YB126 (4) YB126 (4) YB126 (4) YB126 (4) WB1043 (4) 22 Sleeve YB127 (2) YB127 (2) YB127 (2) YB127 (2) WB1044 (2) 25 Strainer WR1085A WR1085A WR1085A WR2010 WR-2010 N/S Prestite Caulking YY0270100 YY0270100 YY0270100 YY0270100 YY0270100 N/S Nameplate, Data WC1983 WC1983 WC1983 WC1983 WC-1983 N/S Bundle, Wire WEF728 WEF728 WEF728 WEF728 WEF729 N/S Base, Compressor WCF804 WCF804 WCF804 WCF804 WCF805

Ref Part Unit Size No. Description 06 09 12 15 19

BCWCompressor Section

Components

N/A = Not Applicable.N/S = Not Shown on Diagram.1 Quantity = two (2) on all sizes except 19 which uses four (4).

Page 13: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 13

BCWChassis and Fan Deck

Diagrams

70

37

6848

76

7

72

1

49

72

77

69

736

5963

3

65

8

3

64 235

6

60

16

22

23

67

53

52

20

54

4

51

17

55

58

4 68

6

65

70

70

40

76

5639

857

7169

14

71

3940

76

56

3739

56

8

14

50

21

72

66

5

Sizes 12, 15, 19

Sizes 06, 09

or

Page 14: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 14

BCWChassis and Fan Deck

Components

N/A = Not Applicable. N/S = Not Shown on Diagram.1 The original Ranco reversing valves are no longer manufactured. The part #'s listed above are the replacements. If an original reversing valve or coil needs to be replaced, both replacement components must be ordered. Old coils do not fit new valves. New coils do not fit old valves.2 When the above listed reversing valves (except size 09) are no longer available, they may be replaced with a new style valve [and solenoid]. Use the following p/n:106694121 (size 06) or106694122 (sizes 12-19) valve and a new solenoid p/n: 106694207 (24V), 106694203 (115V), 106694204 (208/230V) or 106694205 (265V).

Ref Part Qty. Unit Size No. Description 06 09 12 15 19 1 Bulkhead 1 WC1938 WC1938 WC1939 WC1939 WC1939 2 Bottom 1 WC1924 WC1924 WC1925 WC1925 WC1925 3 Cover-Compressor Compart 2 WC1954 WC1954 WC1954 WC1954 WC1954 4 Cover Chassis 2 WC1919 WC1919 WC1920 WC1920 WC1920 5 End, Compressor Compart. 1 WC1923 WC1923 WC1923 WC1923 WC1923 6 Vinyl Seal- End 2 WC1911 WC1911 WC1911 WC1911 WC1911 7 Vinyl Seal- Front & Rear 2 WC1912 WC1912 WC1913 WC1913 WC1913 8 Tube, Drain 1 WC2019 WC2019 WC2019 WC2019 WC2019 14 Fan Motor 120/60/1 1 EADQ5911A EADQ5911A N/A N/A N/A 208/240/60/1 1 EBDQ5912 EBDQ5912 EBDQ5914 EBDQ5916 EBDQ5916 277/60/1 1 EWDQ5913A EWDQ5913A EWDQ5915 EWDQ5917 EWDQ5917 16 Tube-Water Supply 1 WL1331 WL1331 WL1331 WL1331 WL1331 17 Tube-Water Return 1 WL1332 WL1332 WL1332 WL1332 WL1332 20 Tube- Cap Tube to Air Coil 1 WL1335 WL1335 WL1335 WL1335 WL1335 21 Tube- Suction- R.V. to Air Coil 1 WL1351 WL1351 WL1336 WL1337 WL1337 22 Tube- R.V. to H.P Switch 1 WL1338 WL1338 WL1338 WL1339 WL1339 23 Tube- Suction- R.V. to Water Coil 1 WL1342 WL1342 WL1342 WL1343 WL1343 35 Partition- Compressor End 1 WCF802 WCF802 WCF802 WCF802 WCF802 36 Partition- Opp. Comp. End 1 WCF803 WCF803 WCF803 WCF803 WCF803 37 Coil- Air 1 WRF576 WRF574 WRF575 WRF573 WRF572 39 Fan Housing 1 WFF502 WFF502 WFF502 (2) WFF502 (2) WFF502 (2) 40 Fan Board 1 WCF706 WCF706 WCF707 WCF707 WCF707 48 Coil- Water 1 WR1294 WR1295 WR1296 WR1297 WR1298 49 Filter 1 WO1004 WO1004 WO1005 WO1005 WO1005 50 Valve- Reversing1,2 1 067284401 067785201 067284501 067284501 067284501 N/S Coil- Reversing Valve1,2 24V 1 067010001 067010001 067010001 067010001 067010001 120V 1 066541902 066541902 066541902 066541902 066541902 208V 1 066541903 066541903 066541903 066541903 066541903 277V 1 066541904 066541904 066541904 066541904 066541904 51 Switch- High Pressure 1 4EMB5471C 4EMB5471C 4EMB5471C 4EMB5471C 4EMB5471C 52 Cap Tube 1 WL1105A WL1091 WL1456 WL1107B WL1454 53 Strainer 1 WR1210 WR1210 N/A N/A N/A 54 Strainer 1 N/A N/A WR1211 WR1211 WR1211 55 Tee- H.P. Switch 1 4FDP2049 4FDP2049 4FDP2049 4FDP5508 4FDP5508 56 Fan Wheel 1 WF1003 WF1003 WF1003 (2) WF1003 (2) WF1003 (2) 57 Clamp, Motor 2 4DCZ5666 4DCZ5666 4DCZ5666 4DCZ5666 4DCZ5666 58 Elbow- Water Supply 1 4FDF7241 4FDF7241 4FDF7241 4FDF2031 4FDF2031 59 Tee- Water Return 1 4FDP5625 4FDP5625 4FDP5625 4FDP5625 4FDP5625

Page 15: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 15

BCWChassis and Fan Deck

Components, Continued

Ref Part Qty. Unit Size No. Description 06 09 12 15 19 60 Grommet 2 4RHD7278 4RHD7278 4RHD7278 4RHD7278 4RHD7278 63 Bushing (Water Return) 1 4FDB2186 4FDB2186 4FDB2186 N/A N/A 64 Wire Nut (Motor Wires) 4 4EDD2274 4EDD2274 4EDD2274 4EDD2274 4EDD2274 65 Label- Danger 2 WC1268A WC1268A WC1268A WC1268A WC1268A 66 Label- Warning 1 WC1743A WC1743A WC1743A WC1743A WC1743A 67 Label- Water Out 1 WC1304 WC1304 WC1304 WC1304 WC1304 68 Label- Oil Instruction 2 4ZOZ7348 4ZOZ7348 4ZOZ7348 4ZOZ7348 4ZOZ7348 69 Bushing- Motor Wires 1 4GZB4245 4GZB4245 4GZB4245 4GZB4245 4GZB4245 70 Wire Tie 4 4GZZ5362 4GZZ5362 4GZZ5362 4GZZ5362 4GZZ5362 71 Wire Tie- Motor Wires 2 4GGZ6469 4GGZ6469 4GGZ6469 4GGZ6469 4GGZ6469 72 Screw 20 4SBA1722 4SBA1722 4SBA1722 4SBA1722 4SBA1722 76 Vinyl Foam (1/8 x 1/2) (ft) var. BJ02505 BJ02505 BJ02505 BJ02505 BJ02505 77 Vinyl Foam (1/4 x 1/2) (ft) var. BJ02501 BJ02501 BJ02501 BJ02501 BJ02501 N/S Screw1 49 4SBA4206 4SBA4206 4SBA4206 4SBA4206 4SBA4206 N/S Primer KK1550101 KK1550101 KK1550101 KK1550101 KK155010

N/A = Not Applicable.N/S = Not Shown on Diagram.1 Quantity is 45 for size 06. This part number applies to all other screws not referenced on diagram.

Page 16: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 16

Ref Part Qty. Unit Size No. Description 06, 09 12, 15, 19 1 Channel, Rear 1 WC1921 WC1922 2 Kickplate 1 WC1926 WC1926 3 Guide, Chassis - Left-hand 1 WL2017 WL2017 4 Guide, Chassis - Right-hand 1 WC2018 WC2018 5 Support- Grille 2 WC1929 WC1929 6 Panel- Front 1 WC1904 WC1905 7 Access Door 1 WC1930 WC1930 13 Top 1 WCF807 WCF808 14 Grille 1 WCF800 WCF801 15 Panel, End - Left-hand 1 WCF708 WCF708 16 Panel, End - Right-hand 1 WCF709 WCF709 21 Screw #8-32 x 3/8 2 4SAC7249 4SAC7249 22 Clip- Canoe 2 4RQD5511 4RQD5511 23 Screw 22 4SBA1722 4SBA1722 24 Washer- Flat 2 4WAA54 4WAA-54 N/S Enamel KK2760101 KK2760101 N/S Primer KK1550101 KK1550101

BCWCabinet Assembly

2

3

6 1

4

21

7

225 14

13

15

16

24

235

N/S = Not Shown on Diagram.

Page 17: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 17

BCWDamper Assembly

18

4

3

20

13

23

20

18

622

8 185

26

15

27

1

2

101614

7

Ref Part Qty. Damper Type No. Description Manual Motorized 1 Arm, Damper Control 1 WC1934 N/A 2 Support-Arm 1 WC1931 N/A 3 Support Damper, Right-hand 1 WC1935 WC1935 4 Support Damper, Left-hand 1 WC1932 WC1932 5 Damper 1 WC1936 WC1936 6 Bracket, Switch 1 1 N/A WE-731 7 Arm, Damper Control 1 N/A WC1933 8 Channel- Cabinet (only with Cabinet by Others) 1 WC1921 WC1921 10 Arm- Crank 1 N/A WCF806 13 Switch- Slide 1 1 N/A 4EAL2959A 14 Motor, Damper 1 N/A WB1018 15 Spring 1 WC2026 WC2026 16 Screw- Set 1 N/A 4SDL2067 18 Screw 8 4SBA6520 4SBA6520 20 Canoe Cup (Nylon Hinge Pin) 3 4RHD5511 4RHD5511 (4) 22 Label, Vent 1 1 N/A WX1051 23 Tag, Damper Motor 1 N/A WB1019 26 Tape, Polyurethane- 1/8"x1/2" 3 ft. 3J02505 3J02505 27 Tape, Polyurethane- 3/8"x1/2" 10 ft. 3J02703 3J02703 N/S Primer KK1550100 KK1550100N/A = Not Applicable.N/S = Not Shown on Diagram.1 These components are only used on Motorized Dampers with the switch option.

Page 18: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 18

BCWNight Setback and Fuses

14

322523

20

1

7

12

8

4

21

1624

151931

9

10131

4041 26

26

42

43

Ref Part Qty. Night Control Application No. Description Unit Mounted Remote 1 Cover, Box 2 WE728 WE728 4 Box, Fab. A 1 WEF734 WEF734 7 Knob- Thermostat 1 4EZBZ1066 N/A 8 Thermostat (TH3) 1 4ELN2721D N/A 9 Relay- Time Delay (TDR) 1 4EWM6314 4EWM6314 10 Switch- Timer (NOT) 1 4ETA64442 4ETA64442

12 Label- Night Stat 1 WE733 N/A 13 Label- (NOT) 1 WX10512 WX10512

14 Bushing (Line Volt Wires) 1 4GZB2929 N/A 15 Bushing (24 Volt Wires) 1 N/A 4GZB1457 16 Grommet (Cap Tube) 1 4RHD1924 19 Clip- Cable 1 4DDB1454 N/A 20 Wire Tie 1 4GZZ5362 4GZ5362 21 Screw for TH3 2 4SAA6366B N/A 23 Screw for TDR 2 4SAA7031 4SAA7031 24 Washer 1 4WAA54 N/A 25 Nut for TDR 2 4NAA168 4NAA168 26 Screw 9 4SBA4206 4SBA4206 31 Washer- Star for NOT 1 4WBA2392 4WBA2392

32 Washer- Star for TDR 1 4WBA23 4WBA23 40 Fuse Holder- Unit Sizes 06 - 15 2 4EHB7111 4EHB7111 Fuse Holder- Unit Size 19 2 4EHB7244 4EHB7244 41 Fuse, 15 Amp- Unit Sizes 06 - 15 2 049128306 049128306 Fuse, 20 Amp- Unit Size 19 2 4EHG7246 4EHG7246 42 Label- Fuse, 15 Amp- Unit Sizes 06 - 15 2 WE745 WE745 Label- Fuse, 20 Amp- Unit Size 19 2 WE746 WE746 43 Screw 4 4SBA2698A 4SBA2698A N/S Bundle- Wire1 1 WEF730 WEF731 N/S Primer KK1550101 KK1550101

N/A = Not Applicable. N/S = Not Shown on Diagram.1 Wire bundle for Night Override Timer is pn: WEF732.2 Used only on units with Night Override Timer (NOT) option.

Page 19: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 19

BCWFront Panel- Vinyl Clad

Ref Part Qty. Unit Size No. Description 06, 09 12, 15, 19 N/S Panel, Front 1 WC1902 WC1903 N/S Pad, Front Panel 1 WX1183 WX1184 N/S Panel, Front 1 WC1904 WC1905

Ref Part Valve Manufaturer No. Description Penn Barber Colman Std. Control Outdoor Reset Std. Control Outdoor Reset

N/S Valve Assembly- Motor & Linkage 1/2" Valve WX1059 WX1063 N/A N/A 3/4" Valve WX1060 WX1064 N/A N/A 1.0" Valve WX1061 WX1065 N/A N/A 1-1/4" Valve WX1062 WX1066 N/A N/A 1-1/2" Valve N/A N/A WX1067 WX1072 2.0" Valve N/A N/A WX1068 WX1073 2-1/2" Valve N/A N/A WX1069 WX1074 3.0" Valve N/A N/A WX1070 WX1075 4.0" Valve N/A N/A WX1071 WX1076 N/S Sensor WX1077 WX1077 N/A N/A N/S Set Point Adjustment WX1078 WX1078 N/A N/A N/S Transformer 120V-24V 4EPC6456 4EPC6456 N/A N/A N/S Outdoor Sensor N/A WX1080 N/A N/A N/S Temperature Controller N/A WX1079 N/A N/A

N/S = Not Shown on Diagram.

2- Way Motorized Hot Water Valve

N/S = Not Shown on Diagram.

Page 20: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 20

BCWWall Thermostat and Cordsets

Ref Part Man. C/O Cordset No. Description Stat 120V 208/240V 277V N/S Thermostat 4ELN9144 N/S Base-Thermostat 4ELN7456 N/S Cordset WE784 WE572 WE573 N/S Box-Receptacle 4EQB33 4EQB33 4EQB33 N/S Receptacle 4EGA4952 4EGA6071 4EGA4986 N/S Cover-Box 4EQB4216 4EQB4216 4EQB4216 N/S Connector Box 4GFC227 4GFC227 4GFC227

N/S = Not Shown on Diagram.

Ref Part Qty. Part No. Description Number N/S Thermostat- Manual Changeover 1 4ELN5492 N/S Thermostat- Automatic Changeover 1 4ELN5493 N/S Thermostat- Institutional Wall 1 4ELN6538 N/S Thermostat Base- Automatic Changeover 1 4ELN5494 N/S Thermostat Base- Auto C/O w/o System or Fan Switch 1 4ELN3007B N/S Thermostat Guard 1 4EQB5563 N/S Thermostat Keylock Cover w/Internal Thermometer 1 4EQB6717 N/S Thermostat Keytlock Cover w/o Internal Thermometer 1 4EQB6765 N/S Thermostat Keylock Cover w/External Thermometer 1 4EQB6766 N/S Aquastat- 2 Stage 1 4ELN5978 N/S Aquastat- 4 Stage 1 4ELN5979 N/S Well, Bulb- 2 or 4 Stage Aquastat 1 4FAA5980

Thermostat Accessories and Aquastats

N/S = Not Shown on Diagram.

Page 21: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 21

BCWEnercon Safety & Operating Control Assembly- Left Side

Diagram

240

12

34 5856

41

5357

44

80

15

70

1754

81

71

18

12

11

54

71

3

55

Page 22: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 22

5

32

23

1

23

14

6866

20

64

65

22

5

72

4

73265

47

23

10

22

23

13

BCWEnercon Safety & Operating Control Assembly- Right Side

Diagram

Page 23: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 23

Ref Part Description Qty. Part No. 1 Box 2 YEF651 2 Frame 1 YC1652 3 Insert 1 WE543B 4 Sub Panel 1 YE738B 5 Terminal Board- TB1, TB2 1 4ECA6084 7 Transformer 1 4EPC7356 10 Wing Nut 2 4NJZ673 11 P.C. Board 1 WE537B 12 Screw 21 4SBG7148 13 Label- TB1 1 WE628 14 Label- TB2 1 WE629 15 Push Button 1 WE538 17 Alarm 1 4EJZ7272 18 Keylock 1 4HAB6012 20 Relay, One Stage 1 WE700 22 Relay, Two Stage 1 WE701 23 Screw 13 4SBA2164 32 Marking Strip 2 4EEZ6957 34 Gauge-Readout 2 WE687 40 Label- Warning 1 WE564D 41 Strap 15 4GZZ5362 44 Label- Sequence 1 WE544B 47 Label- Caution 1 YC1479A 53 Relay 5 4EWJ5638 54 Relay- Time Delay 2 4EWM6083 55 Guard- Terminal 1 WE560A 56 Screw 3 4SAC1997 57 Nut 3 4NAA1996 58 Lockwasher 3 4WBC1995 65 Wire Nut 7 4EDD2274 66 Screw 3 4SAC444 68 Spacer 3 4DDA6978 70 P.C. Board Support 5 4DDZ6986 71 Screw 7 4SBJ6987 72 Resistor 1 4EZS7041 80 Screw 1 4SBA6520 81 Label- Identification 1 4CLR7222 N/S Well- Immersion 1 4GZZ7158 N/S Sensor 1 4EZS7157 N/S Flow Switch 1 4EBZ6092 N/S Transmitter 1 WE688 N/S Primer KK21101

N/S = Not Shown on Diagram.

BCWEnercon Safety & Operating Control Assembly

Components

Page 24: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 24

BCWControls- Unit Mounted Thermostat w/ Manual Changeover

Ref Part Description Qty. Part No. 1 Top Compressor Compartment 1 WC1937 16 Nameplate- Day Stat 1 WE732 17 Switch- Push Button 1 4EAL5499A 19 Thermostat (TH1) 1 4ELN7977 20 Thermostat (TH2) 1 4ELN6719 21 Relay- Reset (RR) 120V 1 4EWJ5678 208V- Unit Sizes 06, 09, 12 1 4EWJ5681 208V- Unit Sizes 15, 19 1 4EWJ5679 277V- Unit Sizes 06, 09, 12, 15 1 4EWJ5677 277V- Unit Size 19 1 4EWJ6051 25 Knob- Thermostat 1 4EBZ1066 26 Box- Utility 1 4EQB33 27 Cover- Box 1 4EQB1327 28 Wire Tie 6 4GZZ6469 29 Wire Tie 1 4GZZ5362 30 Bushing 1 4GZB3846 34 Connector (TH2) 1 4FCC7328 39 Lockwasher- Ground 1 4WBA237 40 Screw- Ground 1 4SAC177 42 Screw for TH1 2 4SAA6366B 45 Screw for TH2 2 4SAA7031 48 Screw for Pushbutton Switch 2 4SBA2648A 59 Nut- Ground Screw 1 4NAA355 N/S Screw- All Attaching Screws Not Listed 8 4SBA4206 N/S Wire Bundle- 120V or 277V 1 WEF722 Wire Bundle- 208/240V 1 WEF723 N/S Wiring Diagram 2 WE735 N/S Primer KK1550101

N/S = Not Shown on Diagram.

20

129

30

59

28

4039

28

42

2726

28

34

45

28

25

1916481721

Page 25: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 25

BCWControls- Unit Mounted Thermostat w/ Automatic Changeover

Ref Part Description Qty. Part No. 1 Top Compressor Compartment 1 WC1937 16 Nameplate- Day Stat 1 WE732 17 Switch- Push Button 1 4EAL1927C 19 Thermostat (TH1) 1 4ELN6959 20 Thermostat (TH2) 1 4ELN6719 21 Relay- Reset (RR) 120V 1 4EWJ5678 208V- Unit Sizes 06, 09, 12 1 4EWJ5681 208V- Unit Sizes 15, 19 1 4EWJ5679 277V- Unit Sizes 06, 09, 12, 15 1 4EWJ5677 277V- Unit Size 19 1 4EWJ6051 25 Knob- Thermostat 1 4EBZ1066 26 Box- Utility 1 4EQB33 27 Cover- Box 1 4EQB1327 28 Wire Tie 6 4GZZ6469 29 Wire Tie 1 4GZZ5362 30 Bushing 1 4GZB3846 34 Connector (TH2) 1 4FCC7328 39 Lockwasher- Ground 1 4WBA237 40 Screw- Ground 1 4SAC177 42 Screw for TH1 2 4SAA6366B 45 Screw for TH2 2 4SAA7031 48 Screw for Pushbutton Switch 2 4SBA2648A 59 Nut- Ground Screw 1 4NAA355 N/S Screw- All Attaching Screws Not Listed 8 4SBA4206 N/S Grommet- Cap Tube 1 4RHD1924 N/S Spring Clip- Cap Tube 1 106456801 N/S Wire Bundle- 120V or 277V 1 WEF724 Wire Bundle- 208/240V 1 WEF725 N/S Wiring Diagram 2 WE735 N/S Primer KK1550101N/S = Not Shown on Diagram.

20

1

30

59

28

4039

28

42

2726

28

34

45

28

25

1916

48

17

21

28

Page 26: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 26

BCWControls- Wall Mounted Thermostat

Ref Part Description Qty. Part No. 1 Top Compressor Compartment 1 WC1937 17 Switch- Push Button 1 4EAL1927C 18 Transformer (TR1) 120V 1 4EPC7356 208/240V 1 4EPC7357 277V 1 4EPC7358 20 Thermostat (TH2) 1 4ELN7248 21 Relay- Reset (RR) 120V 1 4EWJ5678 208V- Unit Sizes 06, 09, 12 1 4EWJ5681 208V- Unit Sizes 15, 19 1 4EWJ5679 277V- Unit Sizes 06, 09, 12, 15 1 4EWJ5677 277V- Unit Size 19 1 4EWJ6051 22 Relay (R2)(R4)- sizes 06-12 & size 15 208/240V only 2 4EWJ5608 Relay (R4)- size 15 277V and size 19 only 1 4EWJ5608 23 Relay (R2)- size 15 277V and size 19 only 1 4EWJ5680 26 Box- Utility 1 4EQB33 27 Cover- Box 1 4EQB1327 28 Wire Tie 5 4GZZ6469 29 Wire Tie 2 4GZZ5362 30 Bushing 1 4GZB3846 33 Bushing- Low Voltage Wires 1 4GZB1457 34 Connector (TH2) 1 4FCC7328 39 Lockwasher- Ground 1 4WBA237 40 Screw- Ground 1 4SAC177 45 Screw for TH2 2 4SAA7031 48 Screw for Pushbutton Switch 2 4SBA2648A 59 Nut- Ground Screw 1 4NAA355 N/S Screw- All Attaching Screws Not Listed 12 4SBA4206 N/S Wire Bundle- 120V or 277V 1 WEF726 Wire Bundle- 208/240V 1 WEF727 N/S Wiring Diagram 2 WE737B N/S Primer KK1550101N/S = Not Shown on Diagram.

20

1

30

59

33

403928 23

2726

18

34

45

28

21

48

22 22

17

2929

or

Page 27: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 27

BCWControls- Label Location

U.L Assy

Control Box

CSA Assy

Compressor Assy

(pn WC2020)

Night Control BoxFuse Assy

Night Setback Assy

Override Timer Assy

Page 28: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 28

10

1416

19

5

119

4

17

219

319

5

110

12

11

BCWMaster & Slave Control Box

18

See Detail A

Detail A

Ref Part Qty. Box No. Description Master Slave 1 Wrap- Box 1 WX1092B WX1092B 2 Cover- Box 1 WX1093A WX1093A 3 Bracket, Transf. 1 WX1094A WX1094A 4 Wire, Jumper 10 WE611 WE611 5 Wire Bundle 1 WEF703 N/A 10 Transformer 1 120V 1 4EPC7356 N/A 208/240V 1 4EPC7357 N/A 277V 1 4EPC7358 N/A 11 Relay (R1) (R2) (R3) 3 4EWJ4640A 4EWJ4640A 12 Socket Relay 3 4EGE6274A 4EGE6274A 14 Bushing, Snap 1 4GZB4245 4GZB4245 16 Nut, Wire 3 4EDD157 N/A 17 Terminal 1 4EDA7029 N/A 18 Screw 6 4SBC4254 4SBC4254 19 Screw 6 4SBA4206 4SBA4206 N/S Thermostat- Low Limit Night Stat 1 4ELN6565 N/A N/S Night Override Timer 1 4ETA6564 N/A N/S Relay- Night 1 4EWM6314 N/A N/S Wire Bundle- F.A. 1 WXF507 N/A N/S Wiring Diagram 1 WE-609E WE-610CN/A= Not applicable.N/S = Not Shown on Diagram.

Page 29: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 29

BCWNight Setback Central Control Panel

8

41

19

117

29

16

30

43

33

33

343

452

12

42

30

44

20

15

49

35

18 33

51

13

See Detail A

See Detail Bfor grounding

Detail B

119

33

50 10

3127

Sec Z-Z25 26

24

Sec X-X

48

Detail A

44 47

Sec Y-Y

Ref. Part Qty. Part No. Description Number 1 Panel 1 WE626B 2 Label- TB1 1 WE628 3 Label- TB2 1 WE629 8 Box 1 YEF 651 10 Switch 1 WEF631A 12 Frame 1 YC1652 13 Insert 1 WE625B 15 Key Lock 1 4HAB6012A 16 Wing Nut 2 4NJZ673 17 Transformer- 500 VA 1 4EPC6047A 18 Time Clock (Tork) 1 Standard 1 4ETA7274 w/Reserve Power 1 4ETA6373 19 Relay (LR) 1 4EWJ3668 20 Terminal Board 1 4ECA2586 24 Housing- Light 1 4EGE4925 25 Lens- Light 1 4EJZ4926 26 Light 1 4EJE4924 27 Knob- Switch 1 4EBZ1066 29 Connector 1 4GFC227 30 Screw 4 4SBC319 31 Washer- Fiber 1 4WAD410 33 Screw 1 4SBA4206 34 Label, Instruction 1 YC1479B 35 Diagram, Wiring 1 WE627G 41 Screw 4 4SBG3154 42 Tape- Electrical .5 ft. YY0160100 43 Relay, Time Delay TDR 3 4EWM6875 44 Terminal Block (TB2) 1 4ECA6084 45 Terminal- Marking Strip 1 4ECA6957 47 Terminal 3 4EDA6965 48 Screw 22 4SBG7148 49 Label- Identification 1 4CLR7222 50 Insulator- Switch 1 WE617 51 Label- Carton 1 4ZUZ7296 N/S Wire Bundle 1 WEF630D N/S Wire Bundle 1 WEF674A N/S Jumper 2 4EDA1929N/S = Not Shown on Diagram.

Page 30: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 30

NomenclatureModel Number Breakdown

AHW, BHW, CHWDate- 1/1/86

S S A HW 33 3 3 0

ConstructionS= StandardZ= Non- Standard

CabinetS= Standard

DesignA= Design "A"B= Design "B"C= Design "C"

Model HW= Horizontal (Enercon)

Unit Size (1000's BTU)09, 12, 19, 26, 33, 40, 51, 62, 93

Voltage & PhaseHeat Pump Only1= 575/60/32= 208/240/60/13= 277/60/14= 208/240/60/35= 460/60/36= 230 or 240/60/17= 208/60/1 (Size 33), 8= 220/240/50/19= 380-415/50/1

Control3= Remote Thermostat- 24V5= Remote Control Box

Always 0

Page 31: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 31

NomenclatureModel Number Breakdown

AVW, BVW, CVWDate- 1/1/86

ConstructionS= StandardZ= Non- Standard

CabinetS= Standard

DesignA= Design "A"B= Design "B"

C= Design "C" (09, 12 only)

ModelVW= Vertical Enercon

Unit Size (1000's BTU)09, 12, 19, 26, 33, 40, 51, 62, 93,124 (01), 186 (02)

Voltage & PhaseHeat Pump Only1= 575/60/32= 208/240/60/13= 277/60/14= 208/240/60/35= 460/60/36= 230 or 240/60/17= 200/60/3 (Unit sizes 124 & 186)8= 220/240/50/19= 380-415/50/1

Control3= Remote Thermostat- 24V5= Remote Control Box

0= Nothing1= Low Speed (Unit Size 124 & 186)2= Medium Speed (Unit Size 124 & 186)3= High Speed (Unit Size 124 & 186)

S S A VW 33 3 3 0

Page 32: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 32

AHW, BHW, CHW, AVW, BVW, CVW Sizes 09- 26

Refrigeration Circuit

Compressor 208-230/1/60 YB115 WB1003 WB1028 WB1005 208-230/3/60 N/A N/A YB0054 N/A 265/1/60 YB116 WB1004 WB1029 WB1006 460/3/60 N/A N/A YB63 N/A 220-240/50/1 YB140 802003129 WB1170 WB1022 Grommet- Compressor Mounting YB126 (4) YB126 (4) WB1043 (4) WB1043 (4) Sleeve- Compressor Mounting YB127 (2) YB127 (2) WB1044 (4) WB1044 (4) Capacitor- Compressor1

208-230/1/60 4ERA7495 4ERA7495 4ERA7500 037516419 265/1/60 4ERA7506 4ERA7506 4ERA7510 802007857 220-240/50/1 4ERA7497 4ERA7497 067291512 802007857 Reversing Valve2 067785201 067785201 0672845014 0672845014

Solenoid Coil 24V2 067010001 067010001 0670100014 0670100014

Freezestat 4ELN5656 4ELN5656 4ELN5656 4ELN5656 Capillary Tube 063090901 WL1092 WL1093 WL1094 Strainer WR1064 WR1065 N/A N/A (Sizes 9 & 12 Only) N/A WR1064 N/A N/A Air Coil- AHW/BHW WRF500A WRF501A WRF518A WRF519A Air Coil- AVW/BVW WRF500A WRF501A WRF523A WRF524A Air Coil- CVW WRF585 WRF586 N/A N/A Water Coil WR1000A WR1001A WR1056B WR1017B Burnout Kit- AHW, BHW 3 WXA120253 WXA120253 WXA190253 WXA260253 Burnout Kit, VW 3 N/A N/A WXA190301 WXA260301

N/A = Not Applicable.1 When ordering a capacitor, a bracket should also be ordered. Unit sizes 09-19 and size 26 208/230/60/1 use bracket YE1038; unit size 26 265/60/1 and 220/240/50/1 use bracket YE1040.2 The original Ranco reversing valves are no longer manufactured. The part numbers listed above are the replacements. If an original reversing valve or coil needs to be replaced, both replacement components must be ordered. Old coils do not fit new valves. New coils do not fit old valves.3 Burnout kit includes Filter Drier WX1090.4 When this reversing valve is no longer available, a new style valve and solenoid will replace it. Order valve p/n 106694122 and solenoid p/n 106694207. The solenoid listed above is NOT compatible with the new style valve, nor is the new solenoid compatible with the valve listed above.

Description Unit Model Number HW09 HW12 HW19 HW26 VW09 VW12 VW19 VW26

Page 33: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 33

AHW, BHW, CHW, AVW, BVW, CVWSizes 09- 26

Fan Components

Description Unit Model Number HW09 HW12 HW19 HW26 VW09 VW12 VW19 VW26 Blower Motor 208-230/1/60 HBDQ5777 HBDQ5777 JBDQ5779 JBDQ5779 265/1/60 HWDQ5778 HWDQ5778 JWDQ5780 JWDQ5780 460/1/60 N/A N/A N/A N/A 220-240/50/1 HMDQ5840 HMDQ5840 JMDQ5841 JMDQ5841 Capacitor- Blower Motor 460/3/60 N/A N/A N/A N/A All other voltages 802007004 802007004 037516404 037516404 Blower Inlet Ring WC1243A WC1243A WC1244A WC1244A Motor Mounting Bracket WC1277 WC1277 WC1277 WC1277 Fan Wheel WF1004 WF1004 WF1005 WF1005

N/A = Not Applicable.

Controls Description Unit Model Number HW09 HW12 HW19 HW26 VW09 VW12 VW19 VW26 Compressor Contactor 208/230/60/1 4EWJ5608 4EWJ5680 4EWJ5680 4EXJ5705 265/60/1 4EWJ5608 4EWJ5608 4EWJ5680 4EWJ5680 220/240/50/1 4EWJ5608 4EWJ5608 4EWJ5680 4EWJ5680 Reset Relay (RR)- 24V 4EWJ5441 4EWJ5441 4EWJ5441 4EWJ5441 Fan Relay (R-4) 4EWJ5608 4EWJ5608 4EWJ5608 4EWJ5608 Freezestat 4ELN5656 4ELN5656 4ELN5656 4ELN5656 High Pressure Switch 4EMB5471C 4EMB5471C 4EMB5471C 4EMB5471C Thermostat- Auto Changeover2 4ELN7546 4ELN7546 4ELN7546 4ELN7546 Thermostat- Auto CO Subbase 4ELN5494A 4ELN5494A 4ELN5494A 4ELN5494A Thermostat - Manual Changeover1 4ELN9144 4ELN9144 4ELN9144 4ELN9144 Thermostat - Manual CO Subbase 4ELN7456 4ELN7456 4ELN7456 4ELN7456 Transformer- 208-230/24, 220-240/24 4EPC7357 4EPC7357 4EPC7357 4EPC7357 Transformer- 265/24 4EPC7358 4EPC7358 4EPC7358 4EPC7358 Transformer- 460/24 N/A N/A N/A N/A

N/A = Not Applicable.1 Original Robertshaw Manual C/O Stat no longer available. When replacing, order new stat and subbase.2 Honeywell T872 Stat no longer available. When replacing with T874, Stat and Subbase must both be ordered.

Page 34: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 34

AHW, BHW, AVW, BVWSizes 33- 51

Refrigeration Circuit

Description Unit Model Number HW33 HW40 HW51 VW33 VW40 VW51 Compressor 208/60/1 WB1007 WB1011 WB10394

230/60/1 WB1008 WB1011 WB10394

208-230/60/3 WB1009 WB1012 WB10405

460/60/3 WB1010 WB1013 WB1042 220-240/50/1 WB1023 N/A N/A 380/415/50/1 WB1013 N/A WB1034 Grommet- Compressor Mounting WB1043 (4) WB1043 (4) YB167 (4) Sleeve- Compressor Mounting WB1044 (4) WB1044 (4) YB168 (4) Capacitor- Compressor1

208-230/1/60 037516419 802007857 4ERA7508 4ERA7510 220-240/50/1 802007857 N/A N/A Reversing Valve2 Units built before 2/76 0665335015 0665335015 0665335015

Units built 2/76 and later 067785301 067785301 0665335015

Bushing- Reversing Valve Units built before 2/76 4FDB3098 4FDB3098 N/A Units built 2/76 and later N/A N/A N/A Solenoid Coil- Rev. Valve 24V2 067010001 067010001 067010001 Freezestat 4ELN5656 4ELN5656 4ELN5656 Capillary Tube WL1095 WL1096 WL1097 Air Coil- AHW/BHW WRF520A WRF521A WRF522A Air Coil- AVW/BVW WRF525A WRF526A WRF527A Water Coil WR1143B WR1143B WR1144A Burnout Kit- AHW, BHW WXA4002533 WXA4002533 WXA5102534

Burnout Kit, VW WXA4003013 WXA4003013 WXA5103014

N/A = Not Applicable. 1 When ordering a capacitor, a bracket should also be ordered. Unit size 33 208/230/60/1 and size 51 use bracket YE1038; unit size 33 220/240/50/1 and unit size 40 use bracket YE1040.2 The original Ranco reversing valves are no longer manufactured. The part numbers listed above are the replacements. If an original reversing valve or coil needs to be replaced, both replacement components must be ordered. Old coils do not fit new valves. New coils do not fit old valves.3 Burnout kit includes Filter Drier WX1095.4 Burnout kit includes Filter Drier YX400.5 This reversing valve is no longer available and may be replaced with the following: valve p/n: 106694107 and solenoid p/n 106694207. (A new solenoid must be ordered, old solenoids and new valves are NOT compatible. New solenoids and old valves are NOT compatible).

Page 35: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 35

AHW, BHW, CHW, AVW, BVW, CVWSizes 33 -51

Fan Components

Description Unit Model Number HW33 HW40 HW51 VW33 VW40 VW51 Blower Motor 208-230/1/60 KBDQ5781 KBDQ5781 LBDQ5931 460/1/60 IVDQ5801K1 KVDQ5940 LVDQ5784 220-240/50/1 KMCQ5844 N/A N/A 380/415/50/1 KMDQ5845 N/A MMDQ5846 Capacitor- Blower Motor 460/3/60 802007004 4ERA7303 037516404 208/240/60/1 & 220/240/50/1 4ERA7303 4ERA7303 037516404 380/415/50/1 037516404 N/A 037516404 Blower Inlet Ring WC1245A WC1245A WC1246A Motor Mounting Bracket WC1253 WC1253 WC2496 Fan Wheel WF1006 WF1006 WF1007N/A = Not Applicable.1 This is a retrofit kit containing motor KVDQ5940 and capacitor 802007046.

Controls

Description Unit Model Number HW33 HW40 HW51 VW33 VW40 VW51 Compressor Contactor 208/230/60/1 and 220/240/50/1 4EXJ5705 4EXJ5705 4EXJ5706 460/60/3 and 380/415/50/3 4EXJ6447 4EXJ6447 4EXJ1907 Reset Relay (RR)- 24V 4EWJ5441 4EWJ5441 4EWJ5441 Fan Relay (R-4) 4EWJ5608 4EWJ5608 4EWJ5608 Freezestat 4ELN5656 4ELN5656 4ELN5656 High Pressure Switch 4EMB5471C 4EMB5471C 4EMB5471C Thermostat- Auto Changeover3 4ELN7546 4ELN7546 4ELN7546 Thermostat- Auto CO Subbase 4ELN5494A 4ELN5494A 4ELN5494A Thermostat , Manual Changeover2 4ELN9144 4ELN9144 4ELN9144 Thermostat , Manual CO Subbase 4ELN7456 4ELN7456 4ELN7456 Transformer, 208-230/24, 220-240/24 4EPC7357 4EPC7357 4EPC7357 Transformer, 460/24 4EPC7371 4EPC7371 4EPC7371 Transformer, 380-415/24 4EPC6481 N/A 4EPC6481N/A = Not Applicable.2 Original Robertshaw Manual C/O Stat no longer available. When replacing, order new stat and subbase.3 Honeywell T872 Stat no longer available. When replacing with T874, Stat and Subbase must both be ordered.

Page 36: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 36

AHW, BHW, AVW, BVWSizes 62- 186

Refrigeration Circuit

Compressor 208-230/1/60 WB1032 (VW) N/A N/A N/A 208-230/3/60 WB1033 WB1035 WB1033 (2) WB1033 (3) 460/3/60 WB1034 WB1036 WB1034 (2) WB1034 (3) 380/415/50/3 WB1041 WB1042 WB1041 (2) WB1041 (3) Grommet- Compressor Mounting 802003055 (4) 802003055 (4) 802003055 (4) 802003055 (4) Sleeve- Compressor Mounting 71035 (2) 71035 (2) 71035 (4) 71035 (4) Capacitor- Compressor1

208-230/1/60 802007855 N/A N/A N/A 802007856 N/A N/A N/A Reversing Valve Until 12/80 WL1058 WL1287A WL1058 WL1058 1/81 and Later WL1058 1066941071 WL1058 WL1058 Solenoid Coil- Rev. Valve Until 12/80- 460/3 WL1157A WL1293 N/A N/A 1/81 and Later- 460/3 WL1157A 1066942071 WL1157A WL1157A Until 12/80- 208/230/1 or 3 WL1008A WL1293 WL1008A WL1008A 1/81 and Later- 208/230/1 or 3 WL1008A 0665419031 WL1008A WL1008A Freezestat 4ELN7626 4ELN7626 4ELN7626 4ELN7626 Air Coil- AHW/BHW WRF544A WRF553A (Upper) WRF789 WRF519A WRF552A (Lower) Air Coil- AVW/BVW WRF548A WRF549A WRF789 WRF519A Water Coil - AHW/BHW WRF546A WRF554A WR1145A WR1145A Water Coil - AVW/BVW WRF550A WRF551A WR1145A WR1145A

N/A = Not Applicable.1 The original Ranco reversing valves are no longer manufactured. The part numbers listed above are the replacements. If an original reversing valve or coil needs to be replaced, both replacement components must be ordered. Old coils do not fit new valves. New coils do not fit old valves.

Description Unit Model Number HW62 HW93 VW62 VW93 VW124 (01) VW186 (02)

Page 37: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 37

AHW, BHW, AVW, BVWSizes 62-186Fan Components

Description Unit Model Number HW62 HW93 VW62 VW93 VW124 (01) VW186 (02) Blower Motor 208/230/60/1 MBDQ5924K1 N/A N/A N/A 208-230/60/3 MBDQ5924K1 N/A N/A N/A 200/60/3 N/A N/A QGCQ5869A RGCQ5871A 230/60/3 N/A N/A QUCQ5870A 020950700 460/60/3 MVDQ5855 OVDQ5857K2 QUCQ5870A 020950700 380/415/50/3 OMCQ5875A PMCQ5876A QMCQ5902 RMCQ5903 Capacitor- Blower Motor 380/415/60/3 067291512 067291512 N/A N/A All other voltages 4ERA74971 4ERA74971 N/A N/A Blower Inlet Ring WC1640 WC1640 WC1640 WC1824 Motor Mounting Bracket WCF648(3) WCF639K N/A N/A Fan Wheel WF1014 WF1015B 073359801 WF1021N/A = Not Applicable.1 Also order bracket pn YE1038A.

Controls

Description Unit Model Number HW62 HW93 VW62 VW93 VW124 (01) VW186 (02) Compressor Contactor 208/230/60/1 4EXJ6539 N/A N/A N/A All 3Ø Units 4EXJ1907 4EXJ6968 4EXJ6968 4EXJ6968 Compressor Control Relay N/A 4EWJ2859 4EWJ2859 4EWJ2859 Reset Relay (RR)- 24V 4EWJ5441 4EWJ5441 4EWJ6967 4EWJ6967 Reversing Valve Relay 4EWJ2859 4EWJ2859 4EWJ5716 4EWJ5716 Fan Motor Contactor 4EXJ5705 4EXJ5705 4EXJ6447 4EXJ6447 Fan Motor Overload N/A N/A 803005225 803005225 High Pressure Switch 4EMB7145 4EMB7145 4EMB7145 4EMB7145 Low Pressure Switch 4EMB6553 4EMB6553 4EMB6553 4EMB6553 Thermostat- Auto Changeover1 4ELN7546 4ELN7546 4ELN7546 4ELN7546 Thermostat- Auto CO Subbase With System & Fan Switch 4ELN5494A 4ELN5494A 4ELN5494A 4ELN5494A With System Switch Only 4ELN6768A 4ELN6768A 4ELN6768A 4ELN6768A Without Switches 4ELN3007C 4ELN3007C 4ELN3007C 4ELN3007C Thermostat - Manual Changeover2 4ELN9144 4ELN9144 4ELN9144 4ELN9144 Thermostat - Manual CO Subbase 4ELN7456 4ELN7456 4ELN7456 4ELN7456 Transformer (TR1) 208/230- 24 4EPC7357 4EPC7357 4EPC7357 4EPC7357 460- 24 4EPC7371 4EPC7371 4EPC7371 4EPC7371 380/415- 24 4EPC6481 4EPC6481 4EPC6481 4EPC6481 Transformer (TR2) 460- 24 N/A 4EPC6541A 4EPC6541A 4EPC6541A 380/415- 24 N/A 4EPC7030 4EPC7030 4EPC7030

N/A = Not Applicable.2 Original Robertshaw Manual C/O Stat no longer available. When replacing, order new stat and subbase.3 Honeywell T872 Stat no longer available. When replacing with T874, Stat and Subbase must both be ordered.

Page 38: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 38

Accessory PanelsMaster/Slave Control Box

Qty. Description Voltage 120 208/240 277 480 1 Transformer 4EPC7356 4EPC7357 4EPC7358 4EPC7371 3 Relay 4EWJ4640A 4EWJ4640A 4EWJ4640A 4EWJ4640A 3 Relay Socket 4EGE6274A 4EGE6274A 4EGE6274A 4EGE6274A

Night Setback Control Panel Qty. Description Style No Reserve Power Reserve Power 1 Transformer 4EPC6047A 4EPC6047A 1 Time Clock 4ETA6369 4ETA6373 1 Relay 4EWJ3668 4EWJ3668 1 Fuse- 6 Amp 4EHG6493 4EHG6493 1 Light Bulb 4EJE4924 4EJE4924 1 Lens 4EJZ4926 4EJZ4926 1 Knob Switch 4EBZ1066 4EBZ1066 1 Keylock 4HAB6012A 4HAB6012A

Qty. Description Date Range 4/84 and later 7/78- 12/83 11/77- 6/78 prior to 11/77 Complete Panel WXA3601200 WXA510229 WXA510229 WXA510229 1 Transformer 4EPC7356 4EPC7356 4EPC7356 4EPC7356 1 PC Board N/A WE537 WE537 WE537 1 Pushbutton WE538 WE538 WE538 WE538 1 Alarm 4EJZ7272 4EJZ7272 4EJZ6020 4EJZ6020 1 Keylock 4HAB6012A 4HAB6012A 4HAB6012A 4HAB6012A 1 Relay- One Stage N/A WE700 CC8102 CC8102 2 Relay- Two Stage N/A WE701 WE540 WE540 1 Controller- Transmitter WE688 WE688 WE688 WE688 1 Fuse- 1 Amp N/A N/A N/A 4EHG6091 1 Gauge- Meter WE687 WE687 WE687 WE542 1 Sensor 4EZS7157 4EZS7157 4EZS7157 WE541 1 Flow Switch 4EBZ6092 4EBZ6092 4EBZ6092 4EBZ6092 1 Resistor N/A 4EZS7041 4EZS7041 4EZS6104 1 Relay N/A 4EWJ5638 4EWJ5638 4EWJ5638 2 Relay- Time Delay (TD1/TD2) 4EWM6083 4EWM6083 4EWM6083 4EWM6083 2 Relay (R1/R3) 4EWJ5441 4EWJ5638 4EWJ5638 4EWJ5638 2 Relay (P1/P2) 802005906 4EWJ5638 4EWJ5638 4EWJ5638 1 Immersion Well 4GZZ7158 4GZZ7158 4GZZ7158 4GZZ7158 1 Signal Adapter (SC) 4EZS7682 N/A N/A N/A 1 Logic Panel (L1) 4EZS7474 N/A N/A N/A 1 Lamp 4EZJ7640 N/A N/A N/A 1 Diode 4EZZ4352 N/A N/A N/A 1 Lamp Mounting Hardware 4EJZ7641 N/A N/A N/A1For panels built between 1/84 and 4/84 (these panels have no AAF nameplate and have vertical temperature gauge and toggle switches.

System Safety and Operating Panel (SSOP)

Repeater Panel Qty. Description Part Number 1 Pushbutton Switch 4EAL2427 4 Relay (R1- R4) 4EWJ3668 1 Diode 4EZZ6510 1 Buzzer 4EJZ7272 1 Solid State Lamp 4EJZ7640 1 Lamp Mounting Hardware 4EJZ7641 1 Wiring Diagram WE822A

Page 39: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 39

Current Courier

Model Number Part Description Part No. EMP-10TC 10 Channel Time of Day and Duty Cycle 4EIS7705 EMP-10TLC 10 Channel Time of Day Demand Limit and Duty Cycle 4EIS7707 EMP-10TCLO 10 Channel Time of Day Demand Limit, Duty Cycle and Optimum Start/Stop 4EIS8006

EMP-20TC 20 Channel Time of Day and Duty Cycle 4EIS7709 EMP-20TLC 20 Channel Time of Day Demand Limit and Duty Cycle 4EIS7711 EMP-20TCLO 20 Channel Time of Day Demand Limit, Duty Cycle and Optimum Start/Stop 4EIS8007

EMP-40TCLO 40 Channel Time of Day Demand Limit, Duty Cycle and Optimum Start/Stop 4EIS8008

EMP-CO Communications Module 4EIS7712

EMP-10BPS 10 Channel Manual By-Pass Switch Door 4EIS7571 EMP-20BPS 20 Channel Manual By-Pass Switch Door 4EIS7572

CCM-32 Multiplexer 4EIS7567 CCM-2048 Computer Multiplexer 4EIS8009

CCT-RF Transmitter 4EIS7569

CCR-2048 Reciever Relay, Multi-Tap 4EIS7904 CCR-2048 Reciever Relay, 480V 4EIS7903

CCR-2 Second Function Relay 4EWJ7868 CCR-SC Signal Coupler 4EIS8010

CCS-RAMP Ramp Software 4EIS8012 CCS-RM Room Master Software 4EIS8011

CCR-BP Repeater 4EIS7570

Page 40: AAF Enercon Heat Pump - Daikin Appliedlit.daikinapplied.com/bizlit/DocumentStorage/WaterSourceHeatPump/... · AAF Enercon Heat Pump ACW, AWW, BCW, BWW, CWW, CW, WW ... size 124 air

Enercon CW, EW, HW, VW, WW 01-93 Vint. A,B,C Rev. M 03/2017 RPL 57112600/ Page 40

Zone-All

Diameter Relief Air Damper Variable Air Damper Part No. 6 inches 4KAB8062 4KAB8075 8 inches 4KAB8063 4KAB8076 10 inches 4KAB8064 4KAB8077 12 inches 4KAB8065 4KAB8078 16 inches 4KAB8066 4KAB8079

Dampers

Dimensions Rows Part Number 6 x 12 1 4LWA8080 9 x 12 1 4LWA8081 12 x 12 1 4LWA8082 12 x 15 1 4LWA8083 12 x 18 2 4LWB8084 12 x 21 2 4LWB8085

Coils

Controllers Valve Energized Valve Energized Valve Energized on Cooling on Heating/Cooling on Heating Supplier AAF Supplier AAF Supplier AAF 1-Stage / 4 Zones ZC1HC 4EZS8069 ZC1R 4EZS8071 ZC1HW 4EZS8061 2-Stage / 4 Zones ZC2HC 4EZS8070 ZC2R 4EZS8072 ZC2HW 4EZS8068 1-Stage / 8 Zones N/A ZEU1 4EZS8073 N/A 2-Stage / 8 Zones N/A ZEU2 4EZS8074 N/A

Controllers

Dimensions Part Number Control Valve 4FAV8086 Low Limit Thermostat 4ELN8067

Miscellaneous